View Bid Results For Modular Operation Theatre Tenders

We found 173 Bid Results related to modular operation theatre tenders. You can find Contractor details who won modular operation theatre tenders along with contract details in Bid awards announcements section.

Filters
Stage
134
24
15
Tender Publishing Platform
38
135
State / UT
27
77
18
9
8
6
5
5
5
5
4
4
4
3
3
2
2
2
2
1
1
1
1
1
1
1
1
1
Contract Value
41
12
28
91
Publish Date
0
0
0
0
0
Sector
13
77
51
12
10
6
4
4
3
2
1
1
1
1
Ownership
5
106
40
16
10
1
Within keyword
Active filters:
Showing 1–4 of 173 tenders matching your filters
1.
Housing Urban and Rular Development #11346479 Technical Bid
Tender for Construction Of Modular Ot Eye Under Old Sadar Hospital At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
2.
Housing Urban and Rular Development #11346477 Technical Bid
Tender for Construction Of Modular Ot (Eye) Under Sub Divisional Hospital At Madhupur Dist Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
3.
Housing Urban and Rular Development #11346476 Technical Bid
Tender for Construction Of Modular Ot (General & Gynae) At Chc Under Sarwan Block At Deoghar For The Year-2025-26. , Egp. Puff Panels For O.T Wall Walls &Ceiling , Supply, Installation, Testing And Commissioning Of Modular Ot Walland Corner Panels With Insulated Prefabricated Puff Panels. The Ot Wall Shall Be Constructed Using Egp Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The Panel Of The Theatre Shall Be Sufficient For , G.I. Puff Panels For Ot Ceiling , Modular Ot Ceiling Panels With Insulated Prefabricated Puff Panels. The Ot Ceiling Shall Be Constructed Using Gi Puff Panels Having 0.8 Mm Thick Gi Sheets On Both Sides. These Panels Should Have Been Produced In A Double Band Laminator, In Which Two Continuously Moving Belts Carrying 120 Gsm Galvanized Steel Sheets Of 0.80 Mm Thickness Are Firmly Bonded Together By Sprayed -In Insulating Foam, Which Hardens During The Process. The Core Consists Of Rigid Polyurethane Foam, Which Has Been Injected Under High Pressure, With A Minimum Density Of 40Kg/M3. The Thickness Of Puff Shall Be Minimum 40 Mm. The Sheet Panel Shall Be Of Indigenous Reputed Make And Be Provided With Manufactures Test Certificate. The Puff Panel Shall Be Fixed To The Floor With Bottom Track Of 1.5 Mm Thick Steel U Channel Section Having Min Size Of 50Mm X 50Mm. The Bottom Shall Be Fixed In The Floor Of The Ot With 10Mm Thicknessand Min. 60 Mm Long Ss Fasteners Which Shall Be Fully Threaded And Power Drilled. The Panels Of Walls And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Panels Of Wall And Ceiling Shall Be Tied Together By Suitable Ss Coving. The Individual Wall Panels Shall Be Welded Together By Ss. All Joints Shall Be Filled With Metal Filler And Shall Be Sand Casted On Site Till Smooth Finish Is Obtained. Wall & Panel Joints Shall Not Be Visible After The Final Wall Coating Is Applied. The Gap Between The Masonry Wall Surfaces And The , Antibacterial / Antifungal Paint. , Providing And Establishing Anti-Bacterial & Anti Fungicidal Sterile Coating Of Liquid Plastic Paint On Gi Puff/Ss Panel Of Modular Ot. The Paint Should Be Seamless, Easy To Clean, Should Have Vapor Permeability Which Allows Substrate Moisture To Escape And Protects Against Growth Of Bacteria, Mound And Yeasts, Moisture Resistance, Freeze / Thaw Resistance. Anti- Bacterial Anti Microbial Quality Should Remain Active Throughout The Life Of The Product. Vapors Permeable Structure Should Allow Damp Substrates To Dry Out Without Causing Blistering. It Should Tolerate Cleaning With Hospital Chemical Agents. Filling Of All Joints And Cavities Should Be With Metallic Epoxy Filler And Sand Casted Flush To Provide A Joint-Less Finish. This Should Include All Fittings, Accessories, Hardware, Support Structures, Etc. Required For Installation. Anti-Bacterial And Anti-Fungus Sterile Coating Shall Be Applied On The Finished Walls & Ceiling With At Least 2-3 Coats To Achieve A Thickness Of Minimum 200 Micron. Before Application Of Sterile Wall Coating An Appropriate Primer Shall Be Applied. The Primer Shall Be Supplied Along With The Paint And Should Be Of The Same Make As That Of Paint. And Shall Be Applied Prior To Coating Of Anti-Bacterial & Anti- Fungus Sterile Paint On Walls & Ceiling 2-3 Coats Shall Be Applied To Achieve A Thickness Of 200 , Laminar Air Flow , The Range Of Ventilated Ceiling Should Provide The Sterility And Cleanliness Required For Ot Environ Ment. Perfect Tightness Should Be Guaranteed By A N Epoxy Seal Between Filters And Holding Structure Disabling €Œby Pass†Of Hepa Filters. Two Nos . Pressure Measurement Ports Shall Be Provided In Each Housingairflow: 50 +-10% Fpm Class 100/Iso C Lass 5 As Per International Standard & Meets Din 1 946-4. D.O.P. Tested Point To P Oint Scanned Minipleat Hepa Filters Having Followi Ng Technical Specifications To Be Fixed In Above H Ousings F Rame € Aluminium. Type € Flange Type. Media € Micro Fiber Glass . Se Aling Of Media € By Means Of Epoxy. I.P.D. - 15 Mm Wg. F.P.D. € 50 Mm Wg. Separators € Concealed Al. Or Hot Melt G Lue. Capacity € 500 Cfm Size Of Laf - 2400 X 2400 Mmthe Work Should Be Executed As Per The Direction Of Enginee R In Charge , Homogeneous Conductive Pvc Vinyl Flooring In O.T.,Icu,Opd. , Providing And Fixing 2 Mm Thick Homogeneous Conductive Pvc Jeoflor Electro + Sd Roll Acts As A Continous Conductive 10^6 Rt10^8. It Has Preminum Antistatic Properites, ( 100 V) The Product Has To Be Groundedwith An Esd Copper Strip( Cf. Finishes To Meet Its Full Performance The Product Is Non Reactive To Residual Indentation With A Value 0.02 Mm. The Flooring Is A Group Twear Rating Suitableheavey Duty Trafficareasand Bfi-S1 Fire Resisteance. The Product Is Non -Emissive Of Volatile Organic Compounds With 10Ug/M2 ( Tvoc After 28 Days Iso 1000-6.Total Thickness En428 2Mm, En 430 G/Sq.M 2900, Width 426 Cm/Lm 200/20, En (European Standard) En 685 Classs 34-43, Fire Rating En1081 0Hm 1^^6 Rt 10^8 Make Jeo Flor Esd Coundictive Flooring , Writing White Board. , Supply & Installation Of Writing Unit/White Boardof Size 900/600 Mm Having 1.60 Mm Thick White Laminate Board Top, Bonded To A 40 Mm High Density Fiber Board Sheet For Additional Rigidity. The Unit Should Open To Create A Wall Mounted Writing Surface Within The Operating Room. The Work Should Be Executed As Per The Direction Of Engineer-In-Charge. , Storage Unit . , Supply And Installation Of Storage Unit Of Ss 304Of Reputed Make And Having Size 1665 X 865 X350 Mm And Having Two Or More Glass Shelves Of Toughened Glass 10 Mm Thick, Supported With D Type Bracket (Ss 304 Grade) With 10 Mm Thickness And Rubber Gasket Of 2Mm And Mounted Flush On Wall. The Work Should Be Executed As Per The Directions Of Engineer-In-Charge. , Pressure Release Damper. , Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Stabilizer Having Ss Blades To Control Operation Theatre Room - Air Pressure Of Approved Make As Per Tech. Specs Attached. , Peripheral Lights (Dimmable). , Supplying & Fixing Of Sturdy Writing Board Of Size: 840Mm X 640Mm With Perfect Marker Writing Surface In Front And Back Is Laminated To Make Water Proof Surface. The Board Has To Be Provided With Anodized Aluminium Framing And Its Back Should Have Hooks For Wall Hanging Of Approved Make And Type Directly On Wall , Ahu With Outdoor Unit Ac 11.5 Tr Including Insttalation , Double Skin Air Handling Unit :Supply, Installatio N, Testing And Commissioning Of Double Skin Constr Uction Air Handling Units. With Inner Sheet Ss 304 And Ouer Sheet Ppgi With 40 Mm Panel Thickness With Mixing Box With Fa,Ra,Sa Dampers, Fitted With 2 Stage Filteration Arrangment Completed With 10 Micron Filters 5 Mico Nfilter After Fan Section. Suitable For Outdoor In Stallation With 45 Mm Thick Panels With Inner Skin 0.6Mm Thick Aluminium Sheet, Thermal Breack And W Eather Proof.Motor Efficiency Factor - Ie-2Â- Mix Ing Box With Manually Operated Fresh & Return Air Al Dampers.Â- Filter Section With 50 Mm Thick Box Type Pre-Filter (Merv-8) & 305 Mm Thick Rigid Med Ia Type Fine Filter (Merv-10) Mounted On A Common Filter Frame & Viscous/ Wasable Synthetic Type Air Pre-Filterâ- Coil Section With 8 Row Deep Dx Coi L . Fin Material - Plain Aluminium Fin Spacing - 1 1-13 Fpi, Condensing Tray - 22G Ss304, Test Pressu Re - 38Kg/Sq.Cm. Insulation Material For Drain Tra Y-13Mm Thick Close Cell Nitrile Rubber.Â- Uv Lamp , Aluminum Ductiing 22 Gaze , Ducting : ( Al. Sheet Metal )Ducting:- Supply And Fixing Of Site Fabricatedal Sheet Metal Ducts In A Ccordance With Theapproved Shop Drawings And As Re Quired As Per Specifications.All Necessary Gi /Ms Supports Using Thread Rods (As Directed). Angle, F Lat, And Anchor Bolts, Food Grade Neoprene Gaskets , Food Grade Adhesive Included In The Scope. , Insulation , Underdeck Insulation :Supplying And Fixing Of Unde Rdeck Roof Insulation Of 13 Mm Thickness Of Mat Fi Nish Closed Cell Antimicrobile Nitrile Rubber ( Cl Ass O ) Insulation On Existing Surface After App Lying Two Coats Of Cold Setting Adhesive As Requir Ed. , Surgical Scrub (2 Bay). , Supplying, Fixing Installation, Testing Andcommissioning Of Scrub Sink With The Following Specifications:- Compact Surgical Scrub Sink Should Be Designed For Use In Ot Complex For Pre Procedural Scrub Up. (Double Sink Combination Size 1600 Mm X 450Mm X 1650 Mm Back Height& 1200 Mm And Front Heightas Suitable) €¢ Each Fixture Should Be Fabricated From Heavy Gauge Type 304 Stainless Steel (Minimum Thickness1.5Mm) And Should Be Seamless Welded Construction, Polished To A Satin Finish €¢ The Scrub Sink Should Be Provided With A Front Access Panel Which Should Be Easily Removed For Access To The Water Controlled Valve, Waste Connections, Stoppers And Strainers.€¢ Hands Free Operation Should Include Infra-Red Sensors With Programmable Adjustment.€¢ Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature.€¢ Timing Should Be Adjustable To Meet Individual Application Requirements.€¢ Provided With Infrared Sensors, Thermostatic Control Taps With Feel Safe Temperature Controls With Foam Flow Attachments And Provide With Betadine Dispensers .€¢ All Units Should Have Reduced Anti- Splash Fronts. €¢ Knee/Foot Operated Switch Should Be Provided Additionally. The Work , Sliding Type Hermitically Sealed Ot Door (Autometic) , Supply & Fixing Of Sliding Type Ot Door Having High Density Particle Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Standard Size: 1500 X 2100 Mm (W X H) , Surgeon Control Panel. , Supply, Installation, Testing & Commissioning Of Multi Colour Coded Surgeon Control Membrane Touch Panel, Flushed In The Theatre Wall Comprising Of The Following Features & As Per Technical Specification Attached: 1. Display Of Day Clock 2. Display Of Elapse Time Clock 3. Dimmer For Peripheral Lights 4. Medical Gas Alarm 5. Hands Free Telephone 6. Indicator For Temperature & Humidity. , X-Ray View Screen. , Supply, Installation, Testing & Commissioning Of Twin Plate X- Ray Viewing Screen Designed To Provide A High Level Of Control Luminance Without Flickering & As Per The Technical Specification Attached. X-Ray View Screen (Two Screen) Led Overall Dimensions (Lxhxt) 880 X 503 X 29Mm View Area (Wxh) : 736 X 440 Mm Light Source : Led Power Consumption / Input Power : 30W / Ac 100-240V Illumination Intensity : 5,500 Lux Approx. , Surgeon Pendent , Providing & Fixing Of Singale Arm Multi Moveable Surgeons Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthesia Pendant . , Providing & Fixing Of Single Arm (900Mm) Anaesthesia Pendant With Load Carrying Capacity Of 80Kg And Rotational Values Of 330-340 Degree With Adjustable Stopper. The Pendent Should Be Designed With Service Head To Host, Base, Gas Module, Electric Modular And Shelves Upto 8 Gas Outlets & 10 Electrical Switches. Racks & Shelves Should Be Provided To Mount The Equipments Like Monitor Etc. The Surgeon Pendent Should Have Two Arms , Anaesthsia Trolley: Made Of Composite Laminate - Overall Size 950Mmx600mmx570mm H - Cosmokartz Or Equivalent , Eye Ot Table Opthal Ot Table , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro- Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type Water Proof Rubber Mattress 1 Pc. 1 Pair 2 Pcs. 1 Pair 1 Pair 1 Pair 1 Set , Multi Purpose Ot Table With C - Arm Compitable , Cognate Ss- Is A Sophisticated Yet Economical Operating Table Remote Control Specially Designed For C Arm Image Intensifier. Its Unique Design Permits It To Excel Over Competitive Offering In The Areas Of Micro-Neuro, Orthopaedics, Cardiovascular, Ob/Gyn, Ophthalmology, Ent, Urology And Other Major Or Minor Operations, The Electro-Mechanical Driving Mechanism Assures Smooth And Quiet Movements Of The Table Top. The Table Top Is Made Of Radio-Translucent Material For Fluroscopic Capability, Operating Positions Including Height Adjustment, Trendelenberg, Reverse Trendelenberg, Lateral Tilt And Back Section Can Be Controlled Quickly And Accurately With The Help Of Lightweight Hand Control Unit, The Excentrically Positioned Table Top, Without Cross Members, To Optimize Image Intensifier Accessibility For Both A/P & Lateral Exposures Standard Accessories L-Shaped Anaesthetic Frame Shoulder Support With Pad Arm Board With S.S Top Lateral Support With Pad Wrist Strap Knee Crutches Goepal Type , Instrument Trolley Fully Ss - Double Shelf, Three Sides Railings., Mounted On 5 Diawheels , Two With Brakes, Size 30X18X36H All 304Gss , Led Operating Light , Providing & Installation Of Led Operating Light Having Maximum Illuminance (1M): 160,000 + 160,000 Lux At 1M Distance, Electrical Power: 150 + 90 W, Power Consumption: 2X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1X 360° / 1X 330°, Recommended Room Height: At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm / 650 N, Light Body Weight: 9.2 + 7.5Kgs, Light Body Depth: 1X 130 Cm / 1X 140 Cm, Air Shielding Surface: 2 X 330 Cm2 Transformers: 2X 450Va/230V/26V, Brightness Regulator: 2X 20 - 500 Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Dome, Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs : 45,000 Hours Etc As Per Technical Specifications Attached , Electrical Works & Distribution Board : Supply Laying, Fixing And Testing Of Flexible Copper Wire Thick 2.5Mm Single Core For Equipment,Electrical Power Control , Lights, As Per Requirement , Floor Mate (Icu/Ot Grade) Paint Should Not React With Betadine (Yellow Patch Of Betadine One Floor Looks Very Ankwred) , Glove Box , Multiple Electric Plug Points (65A) For Carm Lithoclast Lap Tower With Complete Electrical Fittings. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
5.
Housing Urban and Rular Development #11118160 AOC
Tender For Modular Operation Theatre Items At Sadar Hospital, Jamtara At Jamtara For The Year-2025-26 , Wall And Ceiling Cladding (Approved Makes: Jindal/Tata/Essar) Prefabricated Wall & Ceiling Prefabbicated Modular Operating Theater Using Ppgi Puf Panel (Both Wall & Ceiling) Providing Of Pre-Fabricated Modular Operation Theater With Ppgi Puf Pannel Filled With Puf Of 40 Kg/Cubic Meter (40D) Having Required Mechanical Strength And Better Thermal Insulation Which Saves Energy Construction The Panels Joints Are Properly Cam Locked & Revisited Which Provides A Seamless Sub- Structure Which Again Sanded To A Smooth Finish. Approx. Thickness For Wall 50 Mm, Raiser 40 Mm. And Ceiling 30Mm. , Laminar Air Flow System Supply Installation Testing And Commissioning Of Ceiling Filtration System 2400 X 2400 Mm. The Ceiling Filtration System Shall Be 2.40 Meters X 2.40 Meters And Will Be Integrated With The Adjacent False Ceiling. The Ceiling Shall Be Constructed With A Plenum Box Supplied With Conditioned Air From The Central System Via 8 Nos.Hepa Filters (European Norm En1822:2009; Class H14; Dop 99.97-99.9999% Efficincy For 0.3 Micron Particles) With Pressure Drop Of 300 Pascals At Its Nominal Flow Rates (Supplied With The Plenum), Mounted On The Exit From The Supply Ducting. , Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Weled With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Hermetically Sealed Sliding Door System Fabrication Supply, Installation, Testing & Commissioning Of Sliding Type Hermetically Sealed Ot Door Having High Density Partical Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Size:1800 X 2100 Mm.(Wx H). Automatice Doors: Provided With Radar Switch- 2 Nos., Foot Switch Nos. And Photocell Sensors (Anti Crush Feature) & As Per Tech. Specs.Attached. Automatice Doors Size:(1800 X 2100 Mm.) , Peripheral Lights Supply Installation And Commissioning Of 42W Bottom Opening Room Fixture With Ip 65, Led Make Should Be Nichia/Seoul5 Sdcm, Own Make Bis Certified Islocated Driver, Flicker Free, Class2 Selv Driver, Operating Temperature:-100C To 450C Operating Voltage Range:140-270V, Surge Protecction 3.5 Kv, High Effciency Driver:80-85%, Low Voltage Cut Off Below 130V, Output Short Circuit Protction, Fixture Made Up Of Ms Power Coated White After Phosphochromate Treatment Provided As Standard With Sheet Thickness Of 1.2 Mm. Diffuser Of High Impact Polycarbonate Opal Diffuser With Thickness 1.5Mm For Glare Freeuniform Light Distribution, Power Coating: 60Microns, Lamp Source: High Efficiency Long Life Led Package In Integral Module To Ensure Better Uniformity, Average Life L70b50: 50000 Hours,Thd10%,95, System Efficacy 95-100 Lm/W, Cri80, Ip65, Ik05 Impact Rating, Dimension Will Be , Surgeon Control Panel Supply, Installation, Testing & Commissioning Of Operation Theatre Control Panel Membrane Type: Time Day Clock Time Elapse Clock General And Rgb Lighting System Conntrol (Peripheral Lights And Plenum Lights With Dimming) Medical Gas Alarm Panel 5 Gas- Low, Normal And High Pressure With Sequencing As Per Htm 02 01 Hand Free Telephone Set With Speaker Temperature & Humidity Indicator With Controller Hepa Filter Status Module Room Pressure Indicator/ Differential Pressure Indicator , X-Ray View Screen Supply Installation, Testing & Commissioning Of Twin Plate Led Xray Viewing Screen: Size:940 X 640 X 50 Mm. Approx With Viewing Area, Two Plate X-Ray View Screen (120W), Led Based Technology With Colour Temperature6000k And Lamp Life50,000 Hrs And Brightness In Excess Of 4000 Lux. , Writing White Board Supplying & Fixing Of Sturdy Writing Operating List Board: Made Of Ceramic Surface Having Magnetic Properties And Should Be Flushed To The Wall Of The Operating Room Size 940Mmx 640Mmx 50Mm , Surgeon Pendant Providing & Fixing Of Ceiling Mounted Single Arm Pendant Systems For Surgeon: The Weight Carrying Capacity Of The Arm Should Not Be Less Than 180 Kgs. Load. There Should Be 5 Or 6 Nos. Equipment Loading Shelves. Double Column Of 1000Mm. Single Arm Pivot Range Minimum 900 Mm. Or Above. The Brake (Electromagnetic) Supplied With Indian Origin Multipin 6/16 Annual Periodical Maintenance Electrical Switch+Socket-5Nos. It Should Have 2 No. Rj 45 Data Socket. It Should Have Provision For 06 Gas Outlet Points 2 Oxygen 1 Sa7 1Co2 1 Vacuum Capable Of 340 Degrees Of Rotation. Medical Gas Terminal Units Shall Be Provded By The Mgps Vendor And Shall Be Installed In The Pendant. Usfda , Anesthesia Pendant Ceiling Mounted Rigid Pendant Systems For Anaesthesia: Single Arm Motorized Type Pendants Made Of Aluminum, Powder Coate Dimensions: Double Vertical Column 1200 Mm. Vertical Lift:600 Mm. Horizontal Arms- Total 1000 Mm. Pendant Should Be Prepiped Provided With 5 Nos. Medical Gas Outlets. Outlets Shall Be Connected To Dual Circuit Being Provisioned For All Ozygen 2 Outlets. Nitrous Oxide 1 Outlets Vacuum 1 Outlets. Medical Air 1 Outlets Agss 1 Outlet Colour Coded High Pressure Tubing For Each Gas With Nist Connectors At Ceiling Provided With Prewired 10 Nos 6/16 Amps Sockets And Two Data Sockets Rj45 Instrument Loanding Capacity 180 Kgs. Shelves: Two With Handle And Two Rail Each With Capacity Of 40 Kgs. Drawers One With Handle And Twe Rails Load Capacity 40 Kgs. Swiveling Stainless Steel Vertical Pole , Air Conditioning System: Ahu Supply, Installation & Commissioning Of Air Handling Unit Make: Vts (8.5Tr) (Out Door Unit Make: Blue Star / Carrier) , Aluminum Duction 22 Gauge With Curves & Bends Where Indicated For Easy Flow Of Air Tight By Applying Silicon Sealant After Fabrication. Hangers Will Be Provided To Ducts & Will Be Suspended Be Means Of G.I. Coated Rod & These With Not Be More Than 2.5 Mtr. Apart. Thermal Insulation With 19Mm. Xpe With Aluminum Foil For Supply & 13Mm. Xpe Return Air Ducts. Joints Will Be Lapped With Nitrile Tape For Better Insulation. (Laminar To Ahu & Return Air In All Four Corners) Ahu To Be Placed Near Ot, Not More Than 6 Meters. , Dustbin (Trio) , Storge Unit: Storge Unit: 1 Mm. Thick Stainless Sheet 304. The Storge Unit Should Be Divided 4 Equal Parts And Eachpart Should Have Indivdual Swing 8 Mm. Toughened Glass Door With Quality Stanless Steel Self- Closing Hinges Capable Of 180 Degree Swing Out And Secure Locking System. Each Part Will Be Provided With Removable Stainless Steel Racks Made From½ Circular ( Outer Diameter) Seamless Stniless Steel 304 Tubes Of 1 Mm. Thickness Placed At Intervals Of 1.5 Center To Center. The Overall Dimension Of The Stroge Unit Shall Be 1500 Mm. (Width) X 2100 Mm. (Height) 350 Mm. Depth Being Variable To Suit Architectural Layout. , Supplying, Installation, Testing & Commissioning Of F Floor Mounted, Scrub Station: Compact Surgical 2 Bay Scrub Sink Designed For Use In Ot Complex. Each Fixture Fabricated From Heavy Gauge 1 Mm. Thick Type 304 Stainless Steel Of Seamless Welded Construction, Polished To A Smooth Finish With A Front Access Panel Which Should Include, Stoppers And Strainers. Hands Free Operation Should Include Infra-Red Sensors With Built-In Range Of Adjustment. Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature. User Defined Setting Of Approximately 1 To 3 Min Should Be Available. (Size 1500Mm. X 675Mm. X 1105Mm. For 2 Persons , Electrical Db Supply Installation Testing And Commissioning Of Electrical Distribution Board: Should The Trandformers, If Any, Mains Failure Relays, Electrical Distrition Equipment And Circuit Protection Equipment For All Circuits Within The Operating Theatre. All Internal Wiring Should Terminate In Connectore With Screw And Clamp Spring Connections Of The Clip-On Type Mounted, On A Din Rail And Labelled With Indelible Propritary Lables, Individual Fuses Or Miniature Circuit Breakers Should Protect All Internal Circuits. , Pressure Relief Damper Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Relief Dampers: Suitably Sized Air Pressure Relief Damper Should Be Placed Endabling Differential Room Pressure To Be Maintained.Counter-Weight Balancing System Should Be Prvided In The Prd To Maintain Positive Pressure Inside The Operation Room , C-9001 Supreme, Sliding Top Electric Table , C-9001 Supreme, Sliding Top Electric Table Led Operating Light Led Operating Light Having Following Specifications:- Maximum Luminance (1M): 160,000+160,000 Lux At 1 M Distance, Electrical Power: 150+90W, Power Consumption 2 X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1 X 3600/ 1 X 3300, Recommended Room Height At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm/650 N, Light Body Weight 9.2 + 7.5 Kgs, Light Body Depth: 1 X 130 Cm / 1 X 140 Cm, Air Shielding Surface 2 X 330 Cm2 Transformers: 2 X 450Va/ 230V/26V, Brightness Regulator 2 X 20- 500Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Done Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs: , Uv System: Uv Rays Are Very Effective In Killing A Large Number Of Pathogenic Organisms Of Bacterial, Viral And Fungi Commonly Seen In Operating Theaters Such As Pseudomonas, Clostridium Difficile, Mrsa And Vre , De- Fumigation System: Fumigation In Operation Theatre Is A Process Of Gaseous Sterillization That Is Used For The Killing Of Micro-Organisms And Prevention Of Micro-Organisms And Prevention Of Microbial Grwth In The Air, The Surface Of The Wall, Or The Floor1.000 De-Fumigation Control Panel Is Installed Outside The Operation Theatre To Monitor The Room Pressure And To Start The De- Fumigation System From Outside The Operation Theatre, It Will De-Fumigation The Theatre In A Given Time And Will Switch-Om The Ahu To Increase Operation Theatre Pressure Without Operating The Surgeon Control Panel , Ot Corridor Area & Ot Complex With Per And Post Area Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Welded With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Antibacterial / Antifungal Paint Providing And Applying Antibacterial Paint The Internal Surface Of The Room Walls Will Be Sprayed With Water Based Liquid Plastic Wall Glaze Or Equivalent Anti- Bacterial Paint, Approved By The Architect To A Mimnimum Dry Film Thickness Of 300 Microns. The Plastic Coating Will Overlap The Floor Covering Ceiling System And Doorframes By 25 Mm. To Provde A Continuous Sealed Surface. The Plastice Coating Will Be Non- Reflective And The Colour Will Be Submitted To The Architect For Approval. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Jun 15, 2026 Contract Value : 1.21 Crore
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
11.
Information and Broadcasting #10811892 Price Bid
Tender For E-Tender For The Supply, Installation, Integration, Testing, And Commissioning Of Equipment, Computer Hardware, Software, And Accessories For Cinematography, Digital Intermediate, Audiography, Direction & Screenplay Writing, Film Editing, And Animation & Visual Effects Sections, On Academic Pricing On Turnkey Basis, Along With Comprehensive Onsite Warranty For Three (3) Years , Direction And Screenplay Writing Section - Equipment Requirements , Smart Tvpc Dell Pro Max Tower T2 - Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W), 64Gb (2 X 32 Gb) Ddr5 (5600 Mt/S, Non-Ecc), Nvidia Geforce Rtx 5090 32Gb Gddr7, 3Xdp, 1Xhdmi, 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready/ Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 /Windows 11 Pro / 5 Yrs Support , Smart Tv Sony Bravia 3 Series 189 Cm (75 Inches) 4 K Ultra Ai Smart Led Google Tv , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , External Hard Drive Seagate One Touch 20Tb Usb 3.0 Portable Hdd , Printer Hp Laserjet Mfp M438Dn Multi-Function Monochrome Laser Printer (Toner Cartridge) , Directors Viewfinder Alan Gordan Enterprises Mark Vb Directors View Finder , Video Assist Monitors Blackmagic Video Assist 5 3G 5-Inch Full Hd Lcd Touchscreen 3G-Sdi And Hdmi Inputs/Outputs Supports Up To 1080P60 Recording , Final Draft Final Draft Software Full License (Industry Standard With Life Time License) , Continuity Camera / Script Notes Camera Canon Eos R50 Mirrorless Camera Body With Rf - S 18 - 45 Mm F/4.5 - 6.3 Is Stm , Walkie-Talkies, Head Phones (Sets) Aspera V-9 License Free Walkie Talkie With Standard Accessories Viz Battery, Belt Clip, Rapid Charger And Adaptor, Helifex Antenna, User Manual. , Portable Bluetooth/Monitor Speakers (On-Set Use) Jbl Xtreme 3, Wireless Portable Bluetooth Speaker, Pro Sound With Powerful Bass Radiators, Built-In Powerbank, Partyboost, Ip67 Water & Dustproof, Aux & Type C (Blue, Without Mic) , Digital Clap Board Tribe7 Blackslate7 7.5 Clapperboard E-Image Cb-03 Advanced , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Digital Intermediate Section - Equipment Requirements , Software Davinci Resolve Software Studio Version , Software Adobe Package Software (1 Year Subscription Yearly To Be Renewed) , Software Easy Dcp Software For Resolve , Color Correction Panel Black Magic Design Davinci Resolve Mini Panel , Color Correction Panel Black Magic Design Davinci Resolve Micro Panel , Imac Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse With 1-Year Support , Imac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16-Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Imac Mac Keyboard And Mouse Usb Hub 50000 X 1 No. , Dell Tower Work Stations Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non- Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Dell Tower Work Stations Logitech Mk120 Usb Keybord And Mouse , Dell Tower Work Stations Photoshop System 1 Year Licence Subcription To Be Renewed Annually , Monitor Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe , Monitor Dell Pro 27 Plus Monitor - P2725H / 5Y Basic Advanced Exchange Service , Monitor Eizo Cg319X-4K / 31.1 Inches,4096X2160,350Cd/M2,Dp,Hdmi,Adobe Rgb, Built In Sensor , Tv Sony Bravia 4K Uhd Tv 65Inch , External Hard Disk Samsung Ssd 4 Tb External Hdd , External Hard Disk Seagate One Touch Backup Plus 5Tb Hdd External , Di Equipments Blackmagic Design Capture, Card Ultrastudio 4K Mini , Di Equipments Black Magic Design Ultrastudio Monitor 3G For Mac 15000 X 4 Nos , Di Equipments Black Magic Design Link Card 4K Extreme 12G , Speaker & Headphones Jbl Stage 260F, Stage 245C, Stage 240H, Stage 200P + Denon Avrx- 250 Bituminous Av Receiver 5.1 Home Theatre , Speaker & Headphones Jbl Sb180 Speakers , Speaker & Headphones Akg K52 Headphones , Accessories Wacom Intuos Bluetooth Ctl-6100/K0-Cx Digital Graphics Pen Tablet For Drawing (Black) Medium (10.4-Inch X 7.8-Inch) , Accessories Hdmi 2.1 -5 Metres , Accessoriest Thunderbolt 4(Usb-C) Pro Cable (3 Metres) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Animation & Visual Effects - Equipment Requirements , System Lenovo Think Station Px Workstation | 2 X Intel Xeon Gold 5420+ Processor (2.00 Ghz Up To 4.10 Ghz) | 4 X 128 Gb Ddr5-4800Mt/S (Rdimm, Ecc) | 4 X 12 Tb 7200Rpm Hdd 3.5 Sata Enterprise | Nvidia Rtx A6000 48Gb | Intel Eagle Stream C741 Dual Processor Motherboard | Raid 10 (4 Drives Min) | 1 X 1 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | 1 X 4 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | Integrated Ethernet | 2 X Thermal Kit 250W | Windows 11 Pro 64Bit Pre-Loaded | Wired Keyboard & Mouse | 3 Years Onsite Warranty / Dell Ultrasharp 27 4K Thunderbolt Hub Monitor - U2725Qe , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5070 12Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Software Adobe Creative Cloud All Apps Education Named Subscription License , Software Ai Tools (Google Flow) , Software Davinci Fusion Studio Annual-Commercial , Software Cine Tracer , Software Autodesk Maya Subscription New- Commercial , Software Houdini Academic License , Software Nuke Studio 1-Year Subscription , Laptop Dell Pro Max 16 (Mc16250) Xcto Base / Intel Core Ultra 5 235H, Vpro Enterprise (18Mb, 14 Cores, 14 Threads, Up To 5.00 Ghz Turbo, 45W) / 16Gb: 2X8Gb, Ddr5, 5600 Mt/S, Sodimm, Dual Channel, Non-Ecc / Nvidia C64 Rtx Pro 1000 Blackwell 8Gb Gddr7 / 16 Fhd+ Lcd With 300 Nits, Non- Touch, Fhd Hdr Rgb Camera, Microphone, Wlan / Intel Wi-Fi 6E Ax211, 2X2, 802.11Ax, Bluetooth 5.3 Wireless Card / 512Gb, M.2 2230, Gen4 Pcie Nvme, Ssd, Class 35 / 130W Ac Adapter, Type C (Tco10) / Windows 11 Home / 5Yrs Prosupport Nbd , Smart Tv Smart Tv-32 Inch , Moniters Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe / 3Y Basic Advanced Exchange Service , Other Equipments Logitech Mk120 Usb Keybord And Mouse , Other Equipments Xp-Pen-Deco01 V3 , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Film Editing - Equipment Requirements , Apple Imac Machines Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , Apple Cinema Display 27 Apple Studio Display 5K Retina Display 68.29 Cm / 27 (Diagonal) 5K Retina Display 5120X2880 Resolution At 218 Pixels Per Inch 600 Nits Brightness Support For 1 Billion Colours Wide Colour (P3) True Tone Technology With 1-Year Support , Sennheiser Headphones Hd 280 , Jbl Studio Jbl Monitors/Speakers , External System Connected Ssd External Wd 1Tb Drive , Licenses For Each Software Avid Media Composer Edu 1-Year Subscription New License , Licenses For Each Software Davinci Resolve Software , Licenses For Each Software Fcp Studio , Licenses For Each Software Adobe Premiere Pro Academic License 1-Year Subscription - 3 Nos. , External Backup Hard Drive Wd My Book Backup Drive - 12 Tb , Keyboard/ Mouse Logitech Mk120 Usb Keybord And Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Audiography - Equipment Requirements , Dubbing/Mixing Room - Hardware And Software Protool Ultimate Edu Subscription For Student/Teacher - New , Dubbing/Mixing Room - Hardware And Software Dolby Atmos Renderer , Dubbing/Mixing Room - Hardware And Software Pace Ilok 3 Usb - C Type , Dubbing/Mixing Room - Hardware And Software Merging Techologies Hapi Mkiii , Dubbing/Mixing Room - Hardware And Software Merging Technologies Ada8V3S 8 Ch Mic/Line Ad&Da 192 Khz , Dubbing/Mixing Room - Hardware And Software Merging Technologies Anubis Pro Sps , Dubbing/Mixing Room - Hardware And Software Avid S1 (Includes 1 Year Hw Warranty) , Dubbing/Mixing Room - Hardware And Software Avid S1 Extended Hw Support - Second Year , Dubbing/Mixing Room - Hardware And Software Avid Dock , Dubbing/Mixing Room - Hardware And Software Focusrite Isa428 Mkii 4-Channel Microphone Preamp , Dubbing/Mixing Room - Hardware And Software Apple Mac Studio M3 Ultra Chip With 28-Core Cpu, 60-Core Gpu, 32-Core Neural Engine, 96Gb Unified Memory, 1Tb Ssd Storage, Macos , Dubbing/Mixing Room - Hardware And Software Applecare+ For Mac Studio (M4 Max / M3 Ultra) , Dubbing/Mixing Room - Hardware And Software Sonnet Rackmac Studio Enclosure - 3U Pro Rackmount Enclosure To Install And Secure One Or Two Mac Studio Computers In A Standard 19-Inch Rack , Dubbing/Mixing Room - Hardware And Software Logic Pro - Professional Music Production , Dubbing/Mixing Room - Hardware And Software Steinberg Nuendo 14 - Software (Standard) , Dubbing/Mixing Room - Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Dubbing/Mixing Room - Hardware And Software Samsung 65 Tv For Console Room - 1.63 M (65) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Samsung 55 Tv For Console Room - 1.38 M (55) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Lg 4K Uhd Hybrid Projector , Dubbing/Mixing Room - Hardware And Software Motorised Projector Screen, 10 X 8 Feet, 150 Diag, 4:3 Aspect Ratio, 1080P-3D-4K With Remote , Dubbing/Mixing Room - Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Dubbing/Mixing Room - Hardware And Software Blackmagic Design Ultrastudio Monitor 3G Sdi/Hdmi Playback Device , Dubbing/Mixing Room - Hardware And Software Thunderbolt 3 Cable (6.6, 40 Gb/S, Active) , Dubbing/Mixing Room - Hardware And Software Usb-C Digital Av Multiport Adapter (1 For Each System) , Dubbing/Mixing Room - Hardware And Software Usb C Hub 10Gbps 6-In-1 Multiport Adapter With 4K@60Hz Hdmi, Type A& C 3.2 Data Ports, 100W Pd For Mac , Dubbing/Mixing Room - Hardware And Software Tt0080831/ Netgear Av Line M4250-12M2Xf 12X2.5G And 2Xsfp+ Managed Switch , Dubbing/Mixing Room - Hardware And Software Izotope Rx 11 Standard , Dubbing/Mixing Room - Hardware And Software Mcdsp Sa2 Dialog Processor , Dubbing/Mixing Room - Hardware And Software Waves Diamond Bundle , Dubbing/Mixing Room - Hardware And Software Fab Filter Mixing Bundle , Dubbing/Mixing Room - Hardware And Software Audio Design Desk Subscription (2 Years) , Dubbing/Mixing Room - Hardware And Software Nugen Loudness Toolkit-2 , Dubbing/Mixing Room - Hardware And Software Sis Edicue , Dubbing/Mixing Room -Mics And Speakers Neumann Ma 1 Monitor Alignment Microphone And Calibration System , Dubbing/Mixing Room -Mics And Speakers Multi-Channel Extension For Neumann Ma 1 System Software , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 150 Dsp Powered Studio Monitor , Dubbing/Mixing Room -Mics And Speakers Height Adjustable Stands For Neumann Kh 150 , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 120 Ii Dsp Powered Studio Monitor (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Lh 32 Wall Mounts With Pan And Tilt (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 870 Ii Dsp Dual 10 Studio Subwoofer , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 310 3-Way Reference Studio Monitors Pair (Left And Right) , Dubbing/Mixing Room -Mics And Speakers Kali Lp 6 (Talk Back Speaker Pair For Recording Booth) , Dubbing/Mixing Room -Mics And Speakers Sennheiser Hd 200 Pro Closed-Back Studio Headphones , Dubbing/Mixing Room -Mics And Speakers Neumann Tlm 103 Stereo Set- Nickel (2 X Tlm 103 Ni + Ea1 In Aluminium Case) , Dubbing/Mixing Room -Mics And Speakers Sennheiser E945 Supercardioid Dynamic Vocal Microphone , Dubbing/Mixing Room -Mics And Speakers Rs-719 Heavy Duty Microphone Boom Stand , Dubbing/Mixing Room -Mics And Speakers Rs-521 Medium Weight Notepad/Lyric Stand , Dubbing/Mixing Room -Mics And Speakers Presonus Hp4 Headphone Annual Periodical Maintenance , Dubbing/Mixing Room -Mics And Speakers Promise Pegasus R4 16 Tb Raid With 3 Years Warranty , Dubbing/Mixing Room -Mics And Speakers Rs T3 Pop Shield , Dubbing/Mixing Room -Mics And Speakers 4-Port Professional Hdmi 4K Automatic Video Switch With Fast Switching , Dubbing/Mixing Room -Mics And Speakers Audio Cables And Connectors (Set) And Testing And Calibration , Dubbing/Mixing Room -Mics And Speakers Audio Rack - Black Color With 7 Pairs L Angle With Screws & Nuts & 15 Amps Power Supply With Side Panel And Heavy Duty Wheels , Dubbing/Mixing Room -Mics And Speakers Active Optical Hdmi Cable 25M , Dubbing/Mixing Room -Mics And Speakers Heavy Duty Cat6 Cable 25M , Dubbing/Mixing Room -Mics And Speakers Usb 2.0 Extender Over Cat5E/Cat6 Cable (Rj45) - Up To 165Ft (50M) - High Speed Usb Port Extender Adapter Kit - Powered , Edit Suite- Hardware And Software Pro Tools Studio Annual Paid Annual Subscription Edu , Edit Suite- Hardware And Software Pace Ilok 3 Usb-C Type , Edit Suite- Hardware And Software Neumann Mt 48 Usb-C Audio Interface , Edit Suite- Hardware And Software Neumann Ndh 20 , Edit Suite- Hardware And Software Neumann Kh 80 Dsp Powered Studio Monitor , Edit Suite- Hardware And Software Apple Mac Mini Apple M4 Chip With 10‑Core Cpu, 10‑Core Gpu, 16‑Core Neural Engine, 32Gb Unified Memory, 512Gb Ssd Storage , Edit Suite- Hardware And Software Applecare+ For Mac Mini (M4) , Edit Suite- Hardware And Software Sonnet Rackmac Mini (2024+) - 2U Enclosure To Mount And Secure Up To Three Mac Minis In A Standard 19-Inch Rack , Edit Suite- Hardware And Software Logic Pro - Professional Music Production , Edit Suite- Hardware And Software Neumann Rime Immersive Binaural Monitoring Plug-In , Edit Suite- Hardware And Software Waves Diamond Bundle , Edit Suite- Hardware And Software Lacie 4 Tb External Hdd Thunderbolt Connected , Edit Suite- Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Edit Suite- Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Inter Connection And Storage Equipment Requirements , Storage Centralized Parking Storage For All Departments: Eonstor Gs 3000 G3 3U/16Bay,Cloud-Integrated Unified Storage, Supports Nas, San, Object Protocol And Cloud Gateway, Dual Redundant Controller Subsystem Including 4X12Gb/S Sas Exp. Ports, 4X25Gbe Ports(Sfp28) +4X Host Board Slots,4X16Gb Memory, 2X(Psu+ Fan Module), 2X(Supercap. + Flash Module), 16Xdrive Trays And 1Xrackmount Kit 32X 3.5 Hdd, Sas 12Gb/S, 22Tb, 7200Rpm 3U/16Bay Dual Redundant Controller Expansion Enclosure Including 4X 12Gb Sas Ports, 2X(Psu+Fan Module), 16Xgs Drive Trays, 2X 12G To 12G Sas Cable For Storage Or Expansion Enclosure With 12G Interface And 1Xrackmount Kit 4X 10G Base-Sr Sfp+ Transceiver, Lc, Multi-Mode 3 Years Standard Warranty , Storage Animation Department Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Storage Digital Intermediate Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Interconnection Dell Switch S4148T-On Dell Switch S4148T-On, 1U, 48 X 10Gbase-T, 4 X Qsfp28, 2 X Qsfp+, Io To Psu, 2Xpsu Dell Networking, Qsa Adapter, Qsfp+/Qsfp28 To Sfp/Sfp+/Sfp28 For Select Optics Only (Total-4Nos) Dell Networking, Transceiver, Sfp+, 10Gbe, Sr, 850Nm Wavelength (Total- 4Nos) Dell Networking Cable 100Gbe, Qsfp28 To Qsfp28, Passive Copper Direct Attach Cable, 1 Meter (Total-4Nos) Dell Networking Cable, Om4 Lc/Lc Fiber Cable, (Optics Required), 10 Meter (Total-4Nos) 5 Yrs Pro Support Nbd. , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Cinematography Requirements , Category A: Cameras & Lenses A1. Photography Kit- 1St Year Camera Body- 1St Year Sony A7R5 Body • 61Mp Full-Frame Exmor R Bsi Cmos Sensor • Bionz Xr & Ai Processing Unit • Ai-Based Real-Time Tracking Af System • 8K 24P, 4K 60P, Fhd 120P 10-Bit Video • 4K 16-Bit Raw Output; S-Log3/S-Cinetone • 9.44M-Dot Evf With 120 Fps Refresh Rate • 3.2 4-Axis Multi-Angle Touchscreen Lcd • 10 Fps Shooting With Af/Ae Tracking • 8-Stop 5-Axis Image Stabilization • Dual Cfexpress Type A/Sd Card Slots , Lcd Guard For Sony A7R5 Lcd Panel Guard , Prime Lens 1- 50Mm Sigma 50Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format, Aperture Range: F/1.4 To F/16 • One Molded Glass Aspherical Element • Three Special Low Dispersion Elements • Super Multi-Layer Coating • Floating System & Large Diameter Design • Hyper Sonic Af Motor • Rounded Nine-Blade Diaphragm • Thermally Stable Composite Material • Brass Bayonet Mount • Compatible With Sigma Usb Dock , Uv Filter For Sigma 50Mm Lens Meco 72Mm Uv Filter , Prime Lens 2 35 Mm Sigma 35Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Design , Uv Filter Sigma 35Mm F/1.4 Lens Meco 67Mm Uv Filter , Prime Lens 3 85 Mm Sigma 85Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 85Mm F/1.4 Lens Meco 77Mm Uv Filter , Wide Lens 14Mm Sigma 14Mm F1.8 (E- Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Zoom Lens 1 24-70Mm Sigma 24-70Mm F 2.8 Dg Dn I (E- Mount) Or Equivalent • Full-Frame | F/2.8 To F/22 • Fast & Lightweight Wide-To-Tele Zoom • Hla Autofocus • 6.7 Minimum Focusing Distance • Aperture Ring With Click & Lock Switches • Fld, Sld & Aspherical Elements • Nano Porous & Super Multilayer Coatings • Dust & Splash Resistant , Uv Filter Sigma 24-70Mm Lens Meco 82Mm Uv Filter , Zoom Lens 2 70-200Mm Sigma 70-200Mm F 2.8Mm Dg Dn Os Sport Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Uv Filter Sigma 70-200Mm Lens Meco 82Mm Uv Filter , Telephoto Lens 150-600Mm Sigma 150-600Mm F 5-6.3 Dg Dn Os Sport Or Equivalent • Ef-Mount Lens/Full-Frame Format • Aperture Range: F/5 To F/22 • Two Fld Elements, Three Sld Elements • Super Multi-Layer Coating • Hyper Sonic Motor Af System • Os Image Stabilization • Fixed, Rotating Tripod Collar • Rounded 9-Blade Diaphragm , Uv Filter Sigma 150-600Mm Lens Meco 95Mm Uv Filter , Macro Lens 105Mm Sigma 105Mm F 2.8 Dg Dn Macro Art Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/2.8 To F/22 • One Sld Element • Super Multi-Layer Coating • 1:1 Magnification, 11.6″ Min. Focus • Hyper-Sonic Motor Af System • Custom Afl Button, Focus Limiter Switch • Physical Aperture Ring; De-Click Switch • Rounded 9-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 105Mm F/2.8 Lens Meco 105Mm Uv Filter , Battery Sony Fz100 Battery Or Equivalent ( A7R5 & Fx3A) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 Vdc / 2280 Mah (16.4 Wh) • Infolithium Feature, Dimensions: Approx. 51.7 × 38.7 × 22.7 Mm (W × H × D) • Weight: Approx. 83 G (3 Ozcompatibility: Supports Dozens Of Sony Cameras Including: O Alpha Series: A1, A1 Ii, A9, A9 Ii, A9 Iii, A7 Iii, A7R Iii, A7R Iv, A7 Iv, A7R V, A7S Iii, A7C, A7 C Ii, A7Cr, A6600, A6700 Cinema/V-Logging: Ilme-Fx3, Zv-E1, Zv-E10 Ii , Battery Charger Sony Dual Charger Bc-Zd1 (A7R5) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 V / 2280 Mah (16.4 Wh) • Infolithium Support: Displays Remaining Battery Level On Camera Lcd • Compatibility: Sony Alpha Series (E.G., A1 Ii, A9, A7R Iv, A7 Iv, A6600), Zv Series (Zv-E1, Zv-E10 Ii) • Dimensions: Approx. 38.7 × 22.7 × 51.7 Mm (W × H × D) • Weight: Approx. 83 G (3.0 Oz) • Durability & Safety: Built-In Protection Circuitry To Prevent Overcharging/Overheating (Sony Oem) , Category A2. Video Kit Camera Body-1 (2 Year Continuity Project) Sony Fx6 • 4K Full-Frame 10.2Mp Cmos Exmor R Sensor • Dci 4K60P | Uhd 4K120 | 1080P240 • 15+ Stops Of Dynamic Range In S-Log 3 Electrical Installation • 1.3X And 2.0X Anamorphic De-Squeeze • Compact Form Weighs Less Than 2 Lb • Phase Detection Af/Face Tracking/Eye Af • Base 800-12,800 Iso / 320-409,600 Max • S-Cinetone, S-Log3, Hlg Modes • 10-Bit 4:2:2 Xavc-I/16-Bit Raw Output • Dual Cfexpress Type A/Sdxc Card Slots , Camera Body-2 (3Rd Year Song Project) Sony Fx3A • 12.1Mp Full-Frame Cmos Exmor R Sensor • Uhd 4K Up To 120 | 1080P Up To 240 • Compact Form For Cage-Free Operation • 10-Bit 4:2:2 Xavc S-I,16-Bit Raw Output • S-Cinetone/S-Log3/Hlg, 15+ Stops Dr • Detachable 2 X Xlr/Trs Adapter Handle • Phase Detection Af/Face Tracking/Eye Af • 80 To 409,600 Expanded Iso Range • Dual Cfexpress Type A/Sdxc Card Slots , Battery Sony Fz100 Battery , Panel Guard For Sony Fx3A Lcd Panel Guard , Lens Kit 18Mm, 24Mm, 35Mm, 50Mm, 85Mm, And 105Mm (2Nd And 3Rd Year) Dzo Film, Vespid Ii Prime 6-Lens Set Includes 18Mm,24Mm,35Mm,50Mm,85Mm And 105Mm • Full Frame/Vv | T1.9 To T22 Aperture • 18, 24, 35, 50, 85, And 105Mm Primes • Aspherical Element, Reduced Aberrations • 0.8 Mod Gears, 300° Focus Rotation • Cooke /I Technology Metadata • 80Mm Front Outside Diameter • Compact, Lightweight Design • Less Reflective, More Tactile Surface • Color Matched, Common Gearing And Length • Minimal Breathing And Distortion , Gimbal (3Rd Year Song Project) Rs4 Pro Combo • Lightweight Design With 10 Lb Payload • Combo With Focus Pro Motor • Oled Touchscreen With Auto Lock • 2Nd Gen Native Vertical Shooting • Automated Axis Locks • Joystick Or Bluetooth Mode Switching • Supports Wireless Transmitter, Lidar • Teflon-Coated Axes, Activetrack Pro • 13-Hour Operation Time , Battery Sony Bp-U70 Lithium Ion Battery- (Fx6) • Battery Type: Professional Lithium-Ion Battery (Bp-U Series) • Capacity: 72 Wh • Output Voltage: Approximately 14.4 V Dc Nominal (16.4 V Max) • Charging Time: Approximately 150 Minutes Using Sony Bc-U1A/U2A Charger • Compatibility: Select Sony Professional Camcorders Including Pxw-Fs7, Fx6,.. • Dimensions: 41.5 × 84.5 × 69.7 Mm (1.63 × 3.32 × 2.74 In) Weight: Approximately 450 G (15.9 Oz) • Operating Conditions: Discharge: -20 °C To +45 °C (-4 °F To +113 °F); Charge: 0 °C To +40 °C (32 °F To +104 °F) , Battery Charger Sony Dual Battery Charger Bc-U2A Batteries (Fx6) • Battery Compatibility: Supports Sony Bp-U90, Bp- U60, Bp-U60T, And Bp-U30 Lithium-Ion Batteries. • Charging Capacity: Simultaneously Charges Two Batteries, Optimizing Workflow And Reducing Downtime. • Charge Times: Bp-U90: Approximately 190 Minutes. • Ac Input: 100-240 Vac, 50/60 Hz, Suitable For Global Use. • Dc Output: 12 Vdc Via Integrated Cable, Providing 12 V Dc Power Output While Charging One Battery. • Power Output: 12 Vdc At 3 A (36 W) Via Barrel Connector. • Dimensions: 7.0 × 5.4 × 2.1 Inches (177 × 137 × 53.2 Mm). • Weight: 1.4 Lb (620 G). • Operating Temperature: 32 To 113°F (0 To 45°C). • Certifications: Compliant With Iec62368-1 Safety Standard. , Category B: Photography Lights Flash Light 1 Godox V1 Pro S Or Equivalent • Compatible With Sony Adi / P-Ttl • Output: 76Ws • Auto Zoom Control, Zoom Range: 28-105Mm • 2.4 Ghz X Wireless Radio System • Built-In Led Modeling Lamp • Tilts -7 To 120°, Rotates 330° • Round Head, Optional Magnetic Modifiers • 1.5 Sec Recycle Time, Hss Support • Includes Detachable Sub-Flash , Studio Light 1 Godox Ad 600 Pro Or Equivalent • Built-In 2.4 Ghz Wireless X System • Compatible With Most Ttl Systems • 600Ws, 1/256 To 1/1 Power Output • Lithium-Ion Battery Powered • Up To 360 Full-Power Flashes • Flash Duration: 1/220 To 1/10,100 Sec • 1/8000 Sec High-Speed Sync • 0.01-0.9 Sec Recycling Time • 38W Modeling Lamp • Stable Color Temperature Mode , Studio Light 2 Godox Qt 600 Iii Or Equivalent • 600 Ws, 5600K Color Temperature • 0.01-0.9 Sec Recycling • Flash Duration Hss: 1/26,100 Sec • Built-In Wireless X System • 32 Channels, 16 Groups • Optional X1, X2 & Xpro Transmitter • 1/256 To 1/1 Power Range • 40W Led Modeling Lamp , Softbox Octa Softbox Or Equivalent Jenie Beauty Box 105Cm , Light Stand Harison Heavy Light Stand Harison Heavy Light Stand (Set Of 2) , Strip Box Godox Strip Box 35X160 , Beauty Dish Godox W 550 Silver Eauty Dish With Grid Godox Beauty Dish W550 Sliver With Grid (Set Reflector 1 + Grid 1) , Snoot Godox Snoot , Batteries Eneloop 2000Mah Aa Rechargable Batteries (Set Of 4) , Charger Panasonic Bk 3Hcce Aa Charger , Trigger Godox It 30 Trigger With Flash For Sony Works With X Wireless Radio System Compatible With Sony Adi / P-Ttl Frequency: 2.4 Ghz Range: 328 32 Channels; 99 Ids High-Speed, 1St & 2Nd Curtain Sync Runs On Internal Rechargeable Battery Touchscreen Interface Compact & Portable Design Includes Usb-C Cable & Carry Bag , Category C: Camera Accessories (2Nd And 3Rd Year)Tripod-1 Tripod Manfrotto Mt055-X Pro 3 Or Equivalent • Versatile 3-Section Aluminum Tripod • Spreads To Just 3.5 Above The Ground • 63 Max Height • 23.2 Folded Length • Photo/Video Fluid Tripod Head • 15.4 Lb Load Capacity • All-Direction Photo Mode • Pan-And-Tilt Video Mode • Friction Control , Tripod-2 E Image 7080H • Fluid Head With Bowl Size 75Mm. • Plate With Both 1 /4And 3/8Screws , Memory Card Cf Express Type A 240Gb Or Equivalent (A7R5) & Fx6 , Memory Card Angelbird 1Tb Cf Express Type B Or Equivalent (Burano) , Memory Card Sony 480Gb Tough Card Cf Express Type A , Card Reader 1 Sony Mrw-G3 Cf E Type A Card Reader , Card Reader 2 Sony Mrw-G1 Type B Card Reader , Camera Bag Vanguard Veo 49Bf Camera Bag , Hard Case Camera Hard Case (Pelican Type) (Fx6 & Burano) Explore 7635 Hlb Hard Case For Fx6 & Burano , Camera Cage 1 Small Rig Cage For Sony A7R5 Or Equivalent • Formfitting Camera Cage • 1/4-20 & 3/8-16 Accessory Threads • Maintains Access To Cameras Hot Shoe • Arri-Style Locating Handle Included • Built-In Shoe Mounts, Anti-Twist Design • Threads To Mount Optional Accessories • Durable Aluminum Construction , Camera Cage 2 Small Rig Cage For Sony Fx6 Or Equivalent • Camera Top & Side Plates • Quick Release Baseplate • V-Mount Plate With D-Tap Power Cable • Horizontal & Vertical Mounting • 1/4-20 & 3/8-16 Accessory Threads • 3/8-16 Anti-Twist Threads • Durable Aluminum Construction • Baseplate With Folding V-Lock Plate • 15Mm Rod Clamps & 2 X 15Mm Rods , Mattee Box Mattee Box (Fx6 ) • Compact Matte Box Weighing Only 3.8 Oz • Carbon Fiber Box And Top Flag • Includes 4 X 5.65 Filter Tray • Includes 67/72/77/82-95Mm Adapter Rings • Works With Circular Filters Up To 92.5Mm • 2.2 Lb Maximum Load Capacity , Filters H&Y Nd Filters (0.3,0.6 & 0.9) & Uv Filters (Complete Set) • 0.5 To 3.0 Optical Density • Multicoating & Resistance Coating • Schott B270 Optical Glass • Fits 58-77Mm Lens Filter Threads • High-Grade 6063 Aluminum Construction • Size-Adjustable Adapter Ring • Darkens Entire Image Area • Twist To Attach In Seconds , Filters Polariser Filter (Fx6 & Burano) • Minimize Reflections And Glare • Reduces Haze And Blue Cast In Landscapes • Enhances Color And Tonal Saturation • Colorcore Water White Glass , Field Monitor Atomos Shinobi 7 4K Hdmi/Sdi Monitor • 7 1920 X 1200 Touchscreen Display • 4K60 Hdmi 2.0 In/Out, 2K60 3G-Sdi In/Out • 2200 Cd/M² Brightness • Hdmi/Sdi Cross Conversion • 2.5Mm Camera Control Port For Z Cam E2 • Dual Sony L-Series Battery Slots • Atomos; Atomhdr & 3D Lut Support • 10-Stop Dynamic Range • Supports A Variety Of Log Formats , Measuring Laser Distance Meter , Focus Chart , Colour Checker Calibrite Colorchecker Passport Video 2 (Ccppv2) , Cleaning Kit Lens Cleaning Kit (Professional) , Cables 1 Mtr Cable Hdmi To Hdmi , Cables 0.5 Mtr Cable Sdi To Sdi , Cables 5 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Hdmi To Hdmi , Cables 15 Mtr Cable Hdmi To Hdmi , Category D: Cine-Lineup Cinema Camera (2Nd Year Misc-En & Scene Project) Sony Burano 8K Digital Motion • Compact, Highly Mobile Design • Full-Frame Cmos 8.6K Sensor • 16 Stops Of Dynamic Range • In-Body Image Stabilization|E & Pl Mount • Dual-Base 800/3200 Iso Range • Electronically Variable 0.6-21Nd Filter • Phase Detection Af | Face/Eye Tracking • Full Frame & Super 35 Sensor Modes • Supports Multiple Frame Rates & Codecs • Dual Cfexpress Type B Card Slots , Monitor/ Recorder Shogun Ultra 7 & Recorder • Atomos 11, 12G-Sdi/Hdmi Conversion • 7 1920 X 1080 Touchscreen • Records Up To 8K Apple Prores Raw • Prores Raw + H.265 Dual Recording • Airglu Rf Wireless Sync, Gige, 6E Wi-Fi • 2000 Cd/M² Brightness • Arri/Canon/Red/Sony Camera Sdi Support • Avid Dnx Quicktime • Atomos Remoteview Via Subscription • Optional Ndi 4K Tx Pro Mode 1-Off , Focus System Tilta Nucleus M(Dual Motor) • 1000 Wireless Range • Two Lens Drive Motors • Motors Feature Integrated Receivers • 0.8 Mod Drive Gears • Focus, Iris, Zoom Hand Unit • Motors Daisy-Chain For Power • Right Handgrip With Focus Control • Left Handgrip With Iris And Zoom Control • Hard-Shell Waterproof Case Included , Memory Card Lexar 512Gb Cf Express Type B Card Diamond Series Or Equivalent , Battery Newell V Mount Battery (290 Watts) , Charger Newell V Mount Dual Charger , Lens Kit 8,24,35,50,75, 100Mm Zeiss Nano Prime 6 Lens Kit(18,24,35,50,75,1 00Mm) Set • 18, 24, 35, 50, 75, And 100Mm Lenses • All Lenses Cover Full-Frame Format • T1.5 To T16 Aperture Range • 12-Blade Rounded Iris • Native Lens Data Communication • Zeiss Extended Data • Lens Scale Marked In Feet • Includes Transport Case , 10 &14Mm Laowa Lenses Pl Mount (12Mm Pl Mount Lens) • Full Frame & Vv | T2.6 To T22 Aperture • Zero-D Design, Low-Distortion Optics • 117.8° Fov, 15-Blade Aperture • 16 Elements In 10 Groups • 7.9 Minimum Focusing Distance • 77Mm Filter Thread, 80Mm Front Diameter , Zoom Lens 70-200Mm Zeiss 70-200Mm Cz.2 Lens , Tripod Occnnor 1040 • Tripod: Flowtech 100 Carbon Fiber • Payload Capacity: Up To 45 Lb (20.4 Kg) • Counterbalance: Sinusoidal, Continuously Adjustable • Pan/Tilt Drag: Independent, 9+0 Positions • Tilt Range: +90° To -90° • Tripod Max Height: 60 (152.4 Cm) • Leg Sections: 3, Quick-Release Locks • Floor Spreader: Included • Handle: Pan Handle Included, Attachable Both Sides • Weight: Approx. 12.5 Kg (27.5 Lb) , Camera Cage Tilta Camera Cage For Sony Burano Advanced Kit • Modular Cage For Sony Burano • 15Mm Lws Baseplate, Side Plates • Top Plate, Top Handle, Monitor Mount • Hdmi Cable Clamp, Wi-Fi Tx Bracket • Multiple 1/4-20 & 3/8-16 Threads • Qd Sockets, Shoe Mount, Nato Rails • Side Rosette, 15Mm Rod For Monitor Mount • Aluminum & Stainless Steel Construction , Evf Bracket Rotatable Evf Bracket For Sony Burano Or Equivalent , Tool Kit Tilta Multi Functional Mini Tool Kit • Multi-Functional Mini Tool Kit • Includes 2.5Mm, 3Mm, 4Mm, 3/16 Allen Keys • Flathead & Phillips #2 Screwdrivers, T10 Torx Driver • Aluminum Alloy Frame With Stainless Steel Tools • 3/8-16 And 1/4-20 Threaded Mounts • Compact And Lightweight Design • Integrated Strap Loop For Easy Carry • Color: Titanium Gray • Compatible With Tilta Camera Cages & Support Systems • Portable For Assembly, Disassembly, And On-Set Use , Matte Box Tilta 4X5.6 Carbon Fiber Matte Box Or Equivalent , Adaptor 1 Metabones Pl To E Mount Adaptor , Dry Cabinet Andbon 300 Ltr Dry Cabinet , Light Meter 1 (Common) Sekonic Spectro Master C- 800 Light Meter • Measurement Range: 0.09-18,600 Fc (1-200,000 Lux) • Color Temperature Range: 1600-40,000K • Sensor: High-Resolution Cmos Sensor With 1Nm Increment • Ssi Support: Spectral Similarity Index For Light Matching • Display: 4.3 Color Touchscreen With 11 Display Modes • Cri/Tlci/Tm-30-15: Full Color Rendering Metrics • Flash Measurement: Selectable Shutter Speeds From 1-1/500 Sec • Power: Usb Rechargeable • Connectivity: Usb 2.0 Interface • Dimensions: 73 X 183 X 27 Mm • Weight: 230 G • Included: Carrying Case And Usb Cable , Light Meter 2 (Common) Sekonic Speed Master L858D-U Light Meter • Measuring System: Incident And Reflected Light Metering • Sensor: Spd Sensor • Measuring Range: -5 To 22.9 Ev (Iso 100) • Illuminance Range: 0.1 To 2,000,000 Lux • Iso Range: Iso 3 To Iso 13,107,200 • Shutter Speed Range: 30 Min To 1/80,000 Sec • Display: 2.7 Color Touchscreen Lcd • Flash Measurement: Flash Duration (1/40 To 1/55,500 Sec) • High-Speed Sync (Hss): Supported • Flash Analyzing Function: Yes • Spot Metering: 1° Spot Meter With Viewfinder • Rotating Lumisphere: 270° Rotation, Retractable • Radio Control Modules: Optional For Pocketwizard, Elinchrom/Phottix • Weather Resistance: All-Weather Design • Power: Rechargeable Battery • Dimensions: Approximately 73 X 183 X 27 Mm • Weight: Approximately 230 G , Cine Video Monitor Tv Logic Monitor (Professional Grade) • 1920 X 1080 Resolution Ips Lcd Screen • Composite, 3G-Sdi A/B, Hdmi & Dvi Inputs • Hlg, Pq & Pq2 Hdr Emulation Support • 1 X Composite & 1 X 3G-Sdi Output • 500 Cd/M² Brightness, 178° Viewing Angle • 3.5Mm Audio Headphone Output • Gpi & Ethernet Control • Waveform, Vectorscope, Audio Meter • Focus Assist, H/V Delay, Key Lock, Zoom • Tvlogic Color Calibration Utility & More , Category E: Studio Kit (Common ) Computer Apple Mac Studio M3 Ultra 28 Core Cpu •Apple M3 Ultra 28-Core Cpu •96Gb Unified Ram | 2Tb Ssd •60-Core Gpu | 32-Core Neural Engine •Uhs-Ii Sdxc Card Reader •Wi-Fi 6E (802.11Ax) | Bluetooth 5.3 •6 X Thunderbolt 5 •2 X Usb-A 3.2 Gen 1 | 1 X Hdmi 2.1 •1 X 10 Gigabit Ethernet Port •Macos , Software Final Cut Pro , Software Adobe Psd Annual Subsrciption , Accessories Apple Monitor 27Inch 4K Retina Display , Accessories Apple Keyboard , Accessories Apple Magic Mouse , Accessories Required Cables , Light Controlling Tablet Apple Ipad Pro •13 Ultra Retina Xdr Oled Touchscreen •2752 X 2064 Screen Resolution (264 Ppi) •Apple M4 9-Core Cpu •10-Core Gpu | 16-Core Neural Engine •512Gb Storage | 8Gb Ram •5G Lte | Wi-Fi 6E | Bluetooth 5.3 •Front & Rear 12Mp Ultra Wide Cameras •40 Gb/S Thunderbolt Connectivity •Supports Apple Pencil Pro•Ipados , Display X Lg C3/G3 Oled 65 •Display Type: Qned (Quantum Dot Nanocell Withminiled) •Screen Size: 164 Cm (65 Inches)•Resolution: 3840 X 2160 Pixels (4K Ultra Hd) •Processor: Α7 Ai Processor 4K Gen8 •Color Technology: Dynamic Qned Color With 100%Dci-P3 Coverage •Local Dimming: Advanced Local Dimming Forenhanced Contrast •Hdr Support: Hdr10, Hlg, Dolby Vision •Audio Output: 20W Rms •Audio Technologies: Ai Sound Pro (9.1.2 Channel),Dolby Atmos •Operating System: Webos 2025 With Ai Features •Remote Control: Ai Magic Remote With Ms Copilotintegration •Connectivity: Wi-Fi, Bluetooth, Hdmi, Usb, Ethernet •Voice Assistant: Built-In Google Assistant, Alexasupport •Mounting: Vesa Compatible (300 X 300 Mm) •Dimensions (W X H X D): 1456 X 840 X 29.7 Mm •Weight: 22.5 Kg , Lg 9.1.5 Sound Bar S95Tr (Latest Model) Sound Bar: • Channels & Power: 9.1.5 Configuration With 810 W Total Output And 17 Built-In Speakers •Immersive Audio: Supports Dolby Atmos, Dts:X, Andtriple- Level Spatial Sound For A Cinematic Surroundexperience •Smart Integration: Ai Room Calibration Pro, Woworchestra & Wowcast Enable Seamless Integrationwith Lg Tvs And Wireless Pairing •Connectivity: Includes Hdmi Earc, Hdmi 2.1 Input,Optical, Bluetooth 5.1, Wi-Fi, Usb, Plus Support Forchromecast, Airplay 2, Alexa, And Google Assistant •Setup: Simple Installation Via Power And Single Hdmiconnection With Wireless Rears And Sub; Ideal Formedium-Sized Rooms •Design: Sleek And Low-Profile, Approximately 49.2 ×2.5 × 5.3 Inches (Soundbar); Space-Efficient Setup. , Projector 4K Projector With Screen •Display Technology: 0.65 Dlp •Resolution: 3840 X 2160 Pixels (4K Uhd) •Brightness: 2200 Ansi Lumens •Contrast Ratio: 600,000:1 •Color Gamut: 84% Dci-P3 •Throw Ratio: 0.69-0.83:1 •Zoom: 1.2X Manual Zoom•Focus: Manual •Input Lag: 4.16 Ms (1080P @240Hz) •Hdr Support: Hdr10, Hlg •Audio Output: 5W X 2 Speakers •Audio Features: Earc, Dolby Atmos Passthrough •Operating System: Android Tv (Via Qs02 Dongle) •Streaming Support: Netflix, Youtube, Prime Video,Disney+, Hbo Max, Apple Tv+, Spotify •Connectivity: 2X Hdmi 2.0B, Usb Type-A, Rs232,Audio Out (3.5Mm Mini Jack) •Wireless Features: Wi-Fi 6, Bluetooth 5.0, Googlecast, Apple Airplay •Dimensions: 11 Cm X 30 Cm X 25 Cm •Weight: 3.1 Kg •Power Consumption: 275W (Max), 0.5W (Standby) , Movable Storage 10Tb Desktop External Hdd - Usb 3.0 For Windows And Mac , Ups 1500Va Ups , Computer Speaker 2.1 2.1 Audio Computer Output , Mega Phone Ahuja Bta 550 Wireless Bluetooth Portable 30 Watt Pa • Power Output: 30W Rms • Speaker Configuration: Single 8 Full-Range Dual-Cone Speaker With Tweeter • Microphone Inputs: Two Wired Mic Inputs (4Mv/4.7Kω), One Wireless Mic Input • Auxiliary Input: One Guitar (Aux) Input (100Mv/47Kω) • Tone Controls: Active Bass And Treble Adjustments • Digital Effects: Built-In Digital Echo • Playback Features: Mp3 Player With Bluetooth, Usb, Sd/Mmc Card Support, And Recording Capability • Remote Control: Included For Convenient Operation • Power Sources: Ac Mains, External 12V Dc, Or Built-In 11.1V 2200Mah Rechargeable Li-Ion Battery • Battery Life: Approximately 4 Hours On Battery Power • Construction: Plastic Moulded Cabinet With Trolley System For Portability • With Microphone , Safety Storage Solid Safety Storage To Store Camera With Lock Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) , Category F: Lighting Equipments , Portable Light Kit • Eight Lights With Charging Case • Output: 396 Lux At 3.3 Per Light • 2000-10,000K Cct; Rgb Color Control • 4.2 X 2.7 Panel; 2-Hour Runtime Battery • Cri 96 | Tlci 96 | Cqs 95 | Tm-30 Rf 94 • Onboard, Dmx/Rdm, Crmx & App Control • Tighter 45° Beam Angle • 0-100% Dimming, 15 Special Effects • 1/4-20 & Magnetic Mounting, Ip65-Rated • Includes Mounting Accessories & Cables , Cine Led Bulb Kit Aputure B7C Bulb Kit (8 Bulbs) • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Panel Light 1 Aputure Nova P600 C Panel Light • For Studio & Film/Tv Production Output: 17,520 Lux At 3.3 (5600K) • 2000 To 10,000K; Rgb Color Control • 31.6 X 18.96 Panel, Ac/Dc Operation • Cri 95 | Tlci 95 | Ss1 84 | Cqs 95 • On-Board, Dmx512, Bluetooth App Control • Active Fan Cooling • With Control Box, Yoke, Mounting Clamp • Dimming: 0-100°, Plus/Minus Green Adj. • 300+ Gel Presets, 19 Special Effect , Barn Door Aputure Barndoor For P 600 Light P600Rb4 Barn Door For Aputure P600C Or Equivalent , Soft Box Aputure Softbox P 600R23 • For Studio & Film/Tv Production • Output: 98,500 Lux At 3.3 W/ Reflector • 5600K Cct • Ac Or Battery Power • Onboard, Wireless, Dmx & App Control • Art-Net & Lumenradio • Cri 96 | Tlci 96 | Cqs 94 | Ssi 72 • Active Cooling, Weather-Resistant Design • Bowens S Accessory Mount • Includes Remote, Reflector & Rolling Bag , Cine Led Light Godox M 600R Light For Studio & Film/Tv Production Output: 136,000 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Onboard, Dmx, Crmx & App Control Art-Net & Sacn Ethernet Control Fan Cooled Bowens Mount Ip65 Rated Includes Control Box Includes Power Cable & Soft Case , Cine Light 1 Godox Tl120-K4 Light Four Lights & Remote Control For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case , Cine Light 2 Godox Tl 60-K2 Light Two Lights & Remote Control For Wireless Control From Up To 164 Output: 421 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Bag Remote Control & Carry Case , High Power Light 1 Godox Mg 120 Arc-Biannual Rate Contract Color Light For Photo, Video, Film & Tv Production 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , High Power Light 2 Godox Mg1200 R Light Compatible With Godox G-Mount Modifiers Green/Magenta Adjustments, 14 Effects Upgraded Optical Technology, Ip65 Rated 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , Storm Light 1 Godox Mg4 K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 640,000 Lux At 3.3 W/ Reflector 2800-10,000K Cct; Green/Magenta Shift Ac Power Onboard, Dmx, Crmx, Ethernet & App Improved Fan Cooling System Compatible With Godox G-Mount Modifiers Upgraded Optical Technology & Ip65 Rated 2.4 Diameter Light Source Emitter Includes Controller & Ac Power Cable , Storm Light 2 Godox Mg 6K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 1,025,000 Lux At 3.3 (5600K) 2800-10,000K Cct; Bi-Color Mode Powered Via Ac Cable & Power Controller Onboard, Dmx, Rdm & Bluetooth Control Cri 97 | Tlci 97 Advanced Air Cooling System G-Mount-Compatible & Includes Yoke Ip65-Rated For Dust & Water Protection , Light Mat 1 Aputure Infinimat 4 X 4 Light Mat • Type: Modular Rgbww Led Light Mat • Size: 4 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 1600W, Ac-Powered • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 800W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Mat 2 Aputure Infinimat 2 X 4 • Type: Modular Rgbww Led Light Mat • Size: 2 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 400W, Gold Mount • Power Options: Ac Or Gold Mount Battery • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 400W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Bar 1 Aputure Infinibar Pb 12 4 Light Kit • Output: 617 Lux At 3.3 (120º, 7500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • 8 X 45º Light Control Grids • Flight Case And 330W Power Adapter , Light Bar 2 Aputure Infinibar Pb6 4 Light • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Compact Light 1 Amaran F22C Light • For Studio & Film/Tv Production Output: 6420 Lux At 3.3 (5600K) 2500-7500K Cct; Hsi Color Control • 2 X 2 Mat; Ac/Dc Operation • Cri 95 | Tlci 98 | Cqs 96 • On-Board, Dmx, And Bluetooth Control • Passive Cooling For Silent Operation • 0-100% Dimming, 15 Lighting Effects • Multi-Voltage Ac, V-Mount Battery • Includes Softbox Frame, Diffusers & Grid , Compact Light 2 Godox La 300 R Light For Video Production & Vlogging Output: 94,700 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount, Black Housing Includes Reflector Includes Power Adapter , Compact Light 3 Godox La 150 R Light For Video Production & Vlogging 165W Fixture 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount Includes Reflector Includes Power Adapter , Panel Light 2 Godox Ldx 100 R Light For Video Production And Vlogging Output: 4620 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 18 X 16; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Panel Light 3 Godox Ldx 50 R Light For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Cine Light Kit Aputure Storm 80C- 3 Light Kit Or Equivalent For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Professiona L Light 1 Godox P 1200 R Hard P8 / Arri Sky Panel-X 21 Or Equivalent • Type: Modular Rgbacl Led Panel • Color Temperature Range: 1,500-20,000K • Color Accuracy: Cri ≥99, Tlci ≥93 • Light Output: 16,602 Lux At 3.3 (1M) • Panel Size: 2X1 (29.1 X 13.3 Inches) • Pixel Zones: 8 Independent Zones • Control Options: Wired (Dmx-512), Wireless (Bluetooth Via Lico App, Lumenradio) • Cooling: Passive/Active With Ip66 Rating • Power Supply: Integrated Psu; Daisy-Chainable With Other Skypanel X Units • Mounting: Tool-Less Frame With Quick-Lock System • Compatibility: All S60-C Accessories Via Optional Adapter • Included Accessories: X21 Dome, Manual Yoke, Mains Cable , Hard Light Godox P 1200 R Hard / X21 Hard Light For Arri Sky Panel Or Equivalent P8 X21 Hard Light For Arri Sky Panel Or Equivalent , High Power Light Godox P 1200 R Hard P 8 For Studio & Film/Tv Production Output: 129,200 Lux At 3.3 (5600K) 1800-10,000K Cct; Rgb Color Control 29.2 X 15.2 Panel | Ac Power Cri 96 | Tlci 98 Onboard, Dmx/Rdm, Crmx & App Control Improved Fan Cooling System Flicker-Free Operation Ip65-Rated Weather Resistance Includes Yoke & Ac Power Cable , Dido Lights Godox Ms 600R 2K / Dido Lights Light , Category G: Light Accessories Spotlight Mount 1 Godox Vsa-26 K Spotlight Attachment Projectionlight Kit , Spotlight Mount 2 Godox Vsa-36K Kit Spotlight Attachment Kit , Iris 18 X Godox Vsa-Id Spotlight Mount 36 , Gobo Kit Godox Vsa-Gs1 Gobo Kit , Fresnel 1 Godox Fls 5 Fresnel , Fresnel 2 Godox Fls 10 Fresnel , Barn Door Godox Lb-02 , Light Dome 1 Godox Qr-P 90 T Light Dome , Light Dome 2 Godox S 65 T Light Dome Mini , Light Dome 3 Godox Qr-P 150 T Light Dome , Light Dome Godox Cs 85D Lantern 120 , Light Dome Godox Gp 5 Light Dome , Lantern Godox Cs 85 D Lantern , Reflector Kit Reflector Kit (For 1200X & 1000C) Or Equivalent , Cf12 Fresnel Godox Fls 10 Fresnel , Spotlight Max 1 Godox Gp 36 K Spotlight , Spotlight Max 2 Spotlight Max 50 (For 1200X,1000C,Xt 26) Or Equivalent , Iris Max 18 Godox Gp-Id Iris , Gobo Kit Godox Gobo Kit Godox Gp-Gs1,2,3,4,5 , F14 Fresnel Godox Gf 14 Fresnel , Beam Kit Storm Parallel Beam 70 Kit With Flight Case Or Equivalent , Cf16 Fresnel Cf16 Fresnel With Flight Case Or Equivalent , Stand 1 Dearkol Mfe 5800 (Expandable Up To 17Ft Height & 62Kg Payload) Or Equivalent , Stand 2 Dearkol Mfd 6000 (Expandable Up To 20Ft And 82Kg Payload) Or Equivalent , Soft Box Godox P 1200 Rh Do Softbox , Mounting Rig Godox P 1200 Rh Ad Mounting Rig , Lights Dimmer 5K Dimmer , Skimmer Cloth 10X10 Skimmer Cloth , 12 X12 Skimmer Cloth , 10X10 Black Cloth , 12 X12 Black Cloth , 10X10 Green Cloth , 12 X12 Green Cloth , Backgroung For Photography , Safety Storage For Lights Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) Stainless Steel 0.8Mm, Thickness (Jindal Ss) , Category H: Light Grip Equipments C Stand Godox 270Cs Stand , Par Stand 1 Par Stand Double Height , Par Stand 2 Par Stand Triple Height Or Equivalent , Black Flags 1 4X4 Black Flags Or Equivalent , Black Flags 2 2X1 Black Flags Or Equivalent , Empty Frames 4X4 Empty Frames Or Equivalent , Boom Rods Boom Rods (Various Sizes) Or Equivalent Boom Rods : Stand Height 6Ft To 10Ft, Extension Rod 5 Ft To 10Ft. , Arm Rods Arm Rods (Various Sizes) Or Equivalent , L Rods L Rods (Various Sizes) Or Equivalent , Sand Bag Sand Bag (Professional Grade) Or Equivalent , Skimmer Frame 1 6X6 Skimmer Frames Or Equivalent , Skimmer Frame 2 10X10 Skimmer Frames Or Equivalent , Skimmer Frame 3 12X12 Skimmer Frames Or Equivalent , Grid 1 Honey Comb Grid 6X6 Or Equivalent , Grid 1 Honey Comb Grid 10X10 Or Equivalent , Grid 1 Honey Comb Grid 12X12 Or Equivalent , Loop Boards Loop Boards (Various Sizes) Or Equivalent Solid Wooden Loop Boards (Various Sizes) 20Mtrs 6Pin Socket 2Nos With Led Indicator And A Tripper-15 Nos; 10Mtrs Board With 6Pin Socket 4 Nos With Switch, Led Indicator And A Tripper- 10 Nos; And 20Mtrs Board 6Pin Socket 6Nos With Switch, Led Indicator And A Tripper-5 Nos. , Track System Track & Trolley Full Kit 40Feet Length Manuall 150 Bowl Height 100Kg Capacity With Head , Slider Slider 10Ft Full Kit Or Equivalent , Low Base Stands Low Base Stands , Stand For 100 Bowl Head , Stand For 150 Bowl Head , Cutter Stand , Grip Heads Grip Heads (Professional Grade) , Reflector Board Reflectors 4X4 Board , Low Board , Apple Box Apple Box Setup (Complete Set) Apple Box Setup 20X12X8, 20X12X4, 20X12X2 ,20X12X1 (Complete Set) , Stool Setup Stool Setup 1 Feet , Stool Setup Stool Setup 2 Feet , King Pole- Wall To Wall Mount King Pole (6Ft To 12Ft) , Light Clamps Light Clamps (Various Sizes) , Hydraulic Stand Hydraulic/Windup Stand , Category I: Television Production , Video Camera Sony Hx Z 200 Camera , Mixer Yamaha Mg10X Mixing Console Audio Mixer - Xlr Input/Output, Phono Jack, Level Meter , Recorder Zoom H8 Recorder , Tripod Small Rig Ad80 Carbon Tripod Model No:4163 , Mic And Accessories Sennheiser Lapal Microphone With Cable , Mic And Accessories Rode Boom Pole , Mic And Accessories Rode Ntg4 Mic , Mic And Accessories Rode Blimp , Cables Monitoring Head Phone, Video/Audio Cables And Connectors , Mac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 512Gb Ssd, 24Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours, Keyboard & Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Manpower Deployment , Cost For Deployment Of System Administrator For One (1) Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
13.
Health and Family Welfare #10721867 Price Bid
Tender For Supply, Installation & Commissioning Of Turnkey Projects&Hospital Equipment At Door Delivery Basis At Mehunbare Hospitals, In Jalgaon District , Modular Operation Theatre And Modular Labour Room 1 , Electric O.T. Table(C-Arm Compatible With All Attachments) , Surgical Operating Lights - Ceiling-Mounted, Led Type With Shadowless Function (Double Dome) , Boyles Apparatus , Electrosurgical Unit (Cautery Machine) - Monopolar, Bipolar & Harmonic Modes , Patient Monitor - Multiparameter (Ecg, Spo2, Nibp, Temp, Ibp, Etco2) , Defibrillator With Monitor , Suction Apparatus - Electric, Twin Jar , Ac 1.5 Tr Split , Storage Cabinet , Crash Cart Trolley , O.T. Instrument Set , Autoclave Vertical Fully Automatic (For Cssd) , Wall Panel Pcgi , Ceiling Panel Pcgi , Laminar Air ?Ow 1800 × 2400 , Aluminium Ducting 0.71 With Insulation , Air Handling Unit 2500 Cfm , Outdoor Unit 5.5Tr , 6 Tile Control Panel , Led X-Ray 3 Screen , Writing Board , Peripheral Light , 2Mm Vinyl Flooring , Hinged Door Hpl , Hinged Door Powder Coated (For Passage) , False Ceiling (For Passage) , Theme Light 4X2 (For Passage) , Scrub Station 2 Way (For Passage) , 2Mm Vinyl Flooring (For Passage) , Pendant Single Arm , Pass Box 600×600×600 Mm , Storage Unit , Internal Mgps Line For Pendant , S.S. P.R.D. With Grill , Electrical Wiring External 3 Phase Heavy Duty (Section Outdoor Db To Section Incoming Db) (Material + Labour) (Qty. In Set) , Electrical Wiring Internal (Material + Labour) (Qty. In Set) , Servo Controlled Stabilizer 25 Kva 3 Phase , Ups For Ot Split Ac Back Up With All Its Accessories. , Ups For Ot Lights + Pedestal Fan Back Up With All Its Accessories. , Nabh Validation For O.T. & Hvac Work At The Time Of Handover , Miscellaneous & Minor Work Arising At The Time Of Execution Of The Contract , Transportation , Modular Operation Theatre And Modular Labour Room 2 , Modular Labour Table , Surgical Operating Lights - Ceiling-Mounted, Led Type With Shadowless Function (Double Dome) , Emergency Resuscitation Kit , Patient Monitor - Multiparameter (Ecg, Spo2, Nibp, Temp, Ibp, Etco2) , Suction Apparatus - Electric, Twin Jar , Fetal Monitor / Ctg Machine , Crash Cart Trolley , Baby Warmer , Ac 1.5 Tr Split , Stool & Chair For Staff , Storage Cupboards , Waste Segregation Bins , I. V. Stand , Wall Panel Pcgi , Ceiling Panel Pcgi , Laminar Air ?Ow 1800 × 2400 , Aluminium Ducting 0.71 With Insulation , Air Handling Unit 2500 Cfm , Outdoor Unit 5.5Tr , 6 Tile Control Panel , Led X-Ray 3 Screen , Writing Board , Peripheral Light , 2Mm Vinyl Flooring , Hinged Door Hpl , Hinged Door Powder Coated (For Passage) , False Ceiling (For Passage) , Theme Light 4X2 (For Passage) , Scrub Station 2 Way (For Passage) , 2Mm Vinyl Flooring (For Passage) , Pendant Single Arm , Pass Box 600×600×600 Mm , Storage Unit , Internal Mgps Line For Pendant , S.S. P.R.D. With Grill , Electrical Wiring External 3 Phase Heavy Duty (Section Outdoor Db To Section Incoming Db) (Material + Labour) (Qty. In Set) , Electrical Wiring Internal (Material + Labour) (Qty. In Set) , Servo Controlled Stabilizer 25 Kva 3 Phase , Ups For Ot Split Ac Back Up With All Its Accessories. , Ups For Ot Lights + Pedestal Fan Back Up With All Its Accessories. , Nabh Validation For O.T. & Hvac Work At The Time Of Handover , Miscellaneous & Minor Work Arising At The Time Of Execution Of The Contract , Transportation
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
14.
Health and Family Welfare #10721866 Price Bid
Tender For Supply, Supply, Installation & Commissioning Of Turnkey Projects&Hospital Equipment At Door Delivery Basis At Kingaon Hospitals, In Jalgaon District , Modular Operation Theatre And Modular Labour Room And Equipment 1 , Electric O.T. Table(C-Arm Compatible With All Attachments) , Surgical Operating Lights - Ceiling-Mounted, Led Type With Shadowless Function (Double Dome) , Anaesthesia Workstation - With Ventilator, Vaporizer & Monitor , Electrosurgical Unit (Cautery Machine) - Monopolar, Bipolar & Harmonic Modes , Patient Monitor - Multiparameter (Ecg, Spo2, Nibp, Temp, Ibp, Etco2) , Defibrillator With Monitor , Suction Apparatus - Electric, Twin Jar , Ac 1.5 Tr Split , Storage Cabinet , Crash Cart Trolley , O.T. Instrument Set , Semi Fowler Beds Manual (For Hospital Furniture) , Bed Side Lockers (For Hospital Furniture) , Over Bed Tables (For Hospital Furniture) , Autoclave 20 X 48 Horizontal Fully Automatic (For Cssd) , Wall Panel Pcgi , Ceiling Panel Pcgi , Laminar Air ?Ow 1800 × 2400 , Aluminium Ducting 0.71 With Insulation , Air Handling Unit 2500 Cfm , Outdoor Unit 5.5Tr , 6 Tile Control Panel , Led X-Ray 3 Screen , Writing Board , Peripheral Light , 2Mm Vinyl Flooring , Hinged Door Hpl , Hinged Door Powder Coated (For Passage) , False Ceiling (For Passage) , Theme Light 4X2 (For Passage) , Scrub Station 2 Way (For Passage) , 2Mm Vinyl Flooring (For Passage) , Pendant Single Arm , Pass Box 600×600×600 Mm , Storage Unit , Internal Mgps Line For Pendant , S.S. P.R.D. With Grill , Electrical Wiring External 3 Phase Heavy Duty (Section Outdoor Db To Section Incoming Db) (Material + Labour) (Qty. In Set) , Electrical Wiring Internal (Material + Labour) (Qty. In Set) , Servo Controlled Stabilizer 25 Kva 3 Phase , Ups For Ot Split Ac Back Up With All Its Accessories. , Ups For Ot Lights + Pedestal Fan Back Up With All Its Accessories. , Nabh Validation For O.T. & Hvac Work At The Time Of Handover , Miscellaneous & Minor Work Arising At The Time Of Execution Of The Contract , Transportation , Modular Operation Theatre And Modular Labour Room And Equipment 2 , Modular Labour Table , Surgical Operating Lights - Ceiling-Mounted, Led Type With Shadowless Function (Double Dome) , Emergency Resuscitation Kit , Patient Monitor - Multiparameter (Ecg, Spo2, Nibp, Temp, Ibp, Etco2) , Suction Apparatus - Electric, Twin Jar , Fetal Monitor / Ctg Machine , Crash Cart Trolley , Baby Warmer , Ac 1.5 Tr Split , Stool & Chair For Staff , Storage Cupboards , Waste Segregation Bins , I. V. Stand , Wall Panel Pcgi , Ceiling Panel Pcgi , Laminar Air ?Ow 1800 × 2400 , Aluminium Ducting 0.71 With Insulation , Air Handling Unit 2500 Cfm , Outdoor Unit 5.5Tr , 6 Tile Control Panel , Led X-Ray 3 Screen , Writing Board , Peripheral Light , 2Mm Vinyl Flooring , Hinged Door Hpl , Hinged Door Powder Coated (For Passage) , False Ceiling (For Passage) , Theme Light 4X2 (For Passage) , Scrub Station 2 Way (For Passage) , 2Mm Vinyl Flooring (For Passage) , Pendant Single Arm , Pass Box 600×600×600 Mm , Storage Unit , Internal Mgps Line For Pendant , S.S. P.R.D. With Grill , Electrical Wiring External 3 Phase Heavy Duty (Section Outdoor Db To Section Incoming Db) (Material + Labour) (Qty. In Set) , Electrical Wiring Internal (Material + Labour) (Qty. In Set) , Servo Controlled Stabilizer 25 Kva 3 Phase , Ups For Ot Split Ac Back Up With All Its Accessories. , Ups For Ot Lights + Pedestal Fan Back Up With All Its Accessories. , Nabh Validation For O.T. & Hvac Work At The Time Of Handover , Miscellaneous & Minor Work Arising At The Time Of Execution Of The Contract , Transportation
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
15.
Health and Family Welfare #10721864 Price Bid
Tender For Supply, Installation & Commissioning Of Turnkey Projects&Hospital Equipment At Door Delivery Basis At Mehunbare Hospitals, In Jalgaon District , Modular Operation Theatre And Modular Labour Room 1 , Electric O.T. Table(C-Arm Compatible With All Attachments) , Surgical Operating Lights - Ceiling-Mounted, Led Type With Shadowless Function (Double Dome) , Boyles Apparatus , Electrosurgical Unit (Cautery Machine) - Monopolar, Bipolar & Harmonic Modes , Patient Monitor - Multiparameter (Ecg, Spo2, Nibp, Temp, Ibp, Etco2) , Defibrillator With Monitor , Suction Apparatus - Electric, Twin Jar , Ac 1.5 Tr Split , Storage Cabinet , Crash Cart Trolley , O.T. Instrument Set , Autoclave Vertical Fully Automatic (For Cssd) , Wall Panel Pcgi , Ceiling Panel Pcgi , Laminar Air ?Ow 1800 × 2400 , Aluminium Ducting 0.71 With Insulation , Air Handling Unit 2500 Cfm , Outdoor Unit 5.5Tr , 6 Tile Control Panel , Led X-Ray 3 Screen , Writing Board , Peripheral Light , 2Mm Vinyl Flooring , Hinged Door Hpl , Hinged Door Powder Coated (For Passage) , False Ceiling (For Passage) , Theme Light 4X2 (For Passage) , Scrub Station 2 Way (For Passage) , 2Mm Vinyl Flooring (For Passage) , Pendant Single Arm , Pass Box 600×600×600 Mm , Storage Unit , Internal Mgps Line For Pendant , S.S. P.R.D. With Grill , Electrical Wiring External 3 Phase Heavy Duty (Section Outdoor Db To Section Incoming Db) (Material + Labour) (Qty. In Set) , Electrical Wiring Internal (Material + Labour) (Qty. In Set) , Servo Controlled Stabilizer 25 Kva 3 Phase , Ups For Ot Split Ac Back Up With All Its Accessories. , Ups For Ot Lights + Pedestal Fan Back Up With All Its Accessories. , Nabh Validation For O.T. & Hvac Work At The Time Of Handover , Miscellaneous & Minor Work Arising At The Time Of Execution Of The Contract , Transportation , Modular Operation Theatre And Modular Labour Room 2 , Modular Labour Table , Surgical Operating Lights - Ceiling-Mounted, Led Type With Shadowless Function (Double Dome) , Emergency Resuscitation Kit , Patient Monitor - Multiparameter (Ecg, Spo2, Nibp, Temp, Ibp, Etco2) , Suction Apparatus - Electric, Twin Jar , Fetal Monitor / Ctg Machine , Crash Cart Trolley , Baby Warmer , Ac 1.5 Tr Split , Stool & Chair For Staff , Storage Cupboards , Waste Segregation Bins , I. V. Stand , Wall Panel Pcgi , Ceiling Panel Pcgi , Laminar Air ?Ow 1800 × 2400 , Aluminium Ducting 0.71 With Insulation , Air Handling Unit 2500 Cfm , Outdoor Unit 5.5Tr , 6 Tile Control Panel , Led X-Ray 3 Screen , Writing Board , Peripheral Light , 2Mm Vinyl Flooring , Hinged Door Hpl , Hinged Door Powder Coated (For Passage) , False Ceiling (For Passage) , Theme Light 4X2 (For Passage) , Scrub Station 2 Way (For Passage) , 2Mm Vinyl Flooring (For Passage) , Pendant Single Arm , Pass Box 600×600×600 Mm , Storage Unit , Internal Mgps Line For Pendant , S.S. P.R.D. With Grill , Electrical Wiring External 3 Phase Heavy Duty (Section Outdoor Db To Section Incoming Db) (Material + Labour) (Qty. In Set) , Electrical Wiring Internal (Material + Labour) (Qty. In Set) , Servo Controlled Stabilizer 25 Kva 3 Phase , Ups For Ot Split Ac Back Up With All Its Accessories. , Ups For Ot Lights + Pedestal Fan Back Up With All Its Accessories. , Nabh Validation For O.T. & Hvac Work At The Time Of Handover , Miscellaneous & Minor Work Arising At The Time Of Execution Of The Contract , Transportation
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
16.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Maharashtra View Result →
Contract Date: Jun 23, 2026 Contract Value : 3.38 Crore
Local Bodies No of Bidders 6
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 24.00 Lakh
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2.10 Crore
Government Departments No of Bidders 1
Uttar Pradesh View Result →
26.
Health and Family Welfare #9858569 AOC
Bids Are invited for Indirect Ophthalmoscope - Binocular Indirect Ophthalmoscope With High Quality Coated Optics, Led Illumination With Adjustable Brightness, Wide Field Retinal Viewing, Rechargeable Battery Backup Minimum 4 Hours, Input Power 100 To 240V Ac 50 By 60 Hz Supplied With Headband And Accessories. , Electrocautery Machine - Electrocautery Machine Operating On 110V Ac With Radio Frequency Approx 455 Khz And Rf Output Approx 7 Watt, Compact Powder Coated Metal Body, Lightweight Design Suitable For Ophthalmic Use Supplied With Standard Accessories. , Table Top Flash Autoclave - Table Top Flash Autoclave With Sterilization Temperature 121 And 134 Degree Celsius, Maximum Pressure Approx 0.25 Mpa, Stainless Steel Chamber, Safety Valve And Overheat Protection, Operates On 220V Ac With Water Reservoir And Standard Warranty. , General Operating Table - Motorized General Ot Table With Electric Height Adjustment Approx 700 To 950 Mm, Adjustable Headrest, Antibacterial Mattress, Heavy Duty Powder Coated Frame, Stable Base With Lockable Castors, Hand Remote Control And Manual Override Facility. , Motorized Surgeon Stool - Ergonomic Motorized Surgeon Stool With Cushioned Medical Grade Seat, Height Adjustable Hydraulic Or Pneumatic Mechanism Approx 450 To 650 Mm, Heavy Duty Five Wheel Base With Smooth 360 Degree Rotation And Load Capacity Minimum 120 Kg. , Modular Ot Hpl Material - Modular Operation Theatre With Hpl Wall Panels, Seamless Antibacterial Finish, Walkable Ceiling System, Hermetically Sealed Ot Doors, Hepa Based Laminar Air Flow, Dedicated Medical Hvac Maintaining Positive Pressure, Conductive Ot Flooring, Surgeon Control Panel And Complete Installation As Per Nabh Guidelines. , Cataract Surgical Set - Ophthalmic Cataract Surgical Instrument Set Made Of Medical Grade Stainless Steel, Autoclavable Reusable Instruments Supplied In Standard Sterile Packing With Complete Accessories. Total Quantity : 9
Contract Date: Ref. Documents Contract Value : 1.94 Crore
Government Departments No of Bidders 3
Chhattisgarh View Result →
28.
Educational and Research Institute #9844571 Price Bid
Tender for Specialized Cardiac Unit For Treating Congenital Heart Disease In Neonates And Infant On Turnkey Basis- Phase I At Mdm Hospital, Jodhpur , Specialized Cardiac Unit For Treating Congenital Heart Disease In Neonates And Infant On Turnkey Basis- Phase I At Mdm Hospital, Jodhpur , Specialized Cardiac Unit For Treating Congenital Heart Disease In Neonates And Infant On Turnkey Basis- Phase I At Mdm Hospital, Jodhpur Note: Firm Should Also Quote The Rates Of All Equipments/Turnkey Work Etc. Seperatly As Per Technical Specification In Supplimentry Sheet. Instruments List First Phase Tender Table No. 1 S No Item Quantity Cost Per Item Total , O T Table , Led Operation Theatre Lights , Inhaled Nitric Oxide System , Ventilators , Trans Port Ventilator , Radiant Warmer -Incubator , Radiant Warmer , Transport Incubator , Icu Bed , Portable X Ray Machine , Syrige Pump , Defibrillator , Muliti Para Monitor , 9 Para Monitor , Electro Cautery Vessel Sealer , Anesthesia Work Station With Ventilator , Act Machine , Sternal Saw , Head Light , Dual Chamber External Pacemaker , Intra Aortic Balloon Pump , Operating Loop , Multi Use Chest Retractor , Oscillating Saw , Cardiac Instruments , Nano Fog Ulv Fogger , Electric Suction Mation , Laryngoscope , Autologous Blood Transfusion System - Cell Other Renovation Table No 2 S.No Item Quantity Cost Per Item Total , Renovation Civil Work , Modular Ot Two , Pipe Line - O2, Air & Suction Including O2 & Suction Bottle , Total Building Common Electric Work Like - Wall Clock 01, Desert Cooler & Water Dispenser For Waiting Area - 01, Ss (Stainless Steel ) Scrub Two, Waiting Area Chair , Air Conditioning Other Items Table No.3 S No Item Quantity Cost Total , Ward Bed , Bedside Locker , Attendant Couch , Cardiac Table/Over Bed Table , Crash Cart , Autoclavable Ss Drum , Autoclable Ss Instrument Tray , Revolving Stool , Revolving Stool With Mattress Top , Arm Chair-Swivel- Medium , Office Table , Change Locker , Storage Racks , Bedside Scre
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 2.35 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
30.
Health and Family Welfare #9729046 AOC
Tender for Supply, INSTALLATION And Commissioning Of Advanced Opthalmic Opd With Equipment On Turnkey Basis And Equipments , Advance Ophthalmic Opd With Equipment On Turnkey Basis At District Hospital Solapur , Modular Operation Theatre With Equipments At Sub District Hospital Barshi On Turnkey Basis , Modular Operation Theatre With Equipments At Rural Hospital Trauma Care Centre Sangola On Turnkey Basis , Modular Operation Theatre With Equipments At Rural Hospital Walsang On Turnkey Basis , Supply, Installation And Commimsioning Of Medical Oxygen Gas Pipeline System With Air And Vacuum Compressor At Trauma Care Center Kurduvadi On Turnkey Basis , Supply, Installation And Commimsioning Of Medical Oxygen Gas Pipeline System With Air And Vacuum Compressor At Sub District Hospital Barshi On Turnkey Basis , Supply, Installation And Commimsioning Of Medical Oxygen Gas Pipeline System With Air And Vacuum Compressor At Trauma Care Center Sangola On Turnkey Basis , Computerized Radiology System With Accessoriess And Cassettes , Semi Autoanalyzer , Cell Counter , Diluent 20L (Agd) , Lyse 500Ml (Agd) , Cleaner (Agd) , Diluent 20L (Beaconic) , Lyse 500 Ml (Beaconic) , Cleaner (Beaconic) , X Ray Films 8*10 , X Ray Films 10*12 , X Ray Films 11*14 , Ct Scan Films 14*17 , Laryngoscope With 4 Blade (Adult) , Lobour Table With Head Low Facility , Power Bone Drill , Pneumatic Tourniqet , Anesthesia Work Station , Auto Clave (Horizontal) 2 Drums , Fogger Machine , Weighing Machine Adult , Opthalmic Microscope , Hepa Filter For Laminar Air Flow , Filter For Return Air Riser , 5 Micro Filter For Air Handling Unit , 3 Micro Filter For Air Handling Unit , Gas Charging R22/R410 For Air Handling Unit , Ahu Maintenance Work At Sdh Pandharpur Ot , Reusable Capacitive Coupling Current Quality Monitoring Electrode With Cautery , Lscs Set Of 58 Instruments , Laparotomy Set Of 83 Instruments , Kellys Placetal Forceps Long , Dressing Drum 10X12 , Dressing Drum 12X15 , Stainless Steel Tray With Cov
Contract Date: Apr 28, 2026 Contract Value : 20.10 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
Contract Date: Mar 31, 2026 Contract Value : 1.13 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 3.72 Lakh
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
35.
Housing Urban and Rular Development #9468305 Technical Bid
Tender For Rates For Material/Equipment Regarding Medical Gas Pile Line System And Modular Operation Theatre For Estimate Preparation. - Rates for Material/Equipmentregarding Medical Gas Pile Line System and Modular Operation Theatre for estimate preparation. 2 Medical Gas Pipe Line (Part-A) 3 Oxygen Manifold 4 SITC of 10 + 10 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. as per specification (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 5 Certifications: ISO 13485:2016,ISO 9001:2015, CE 6 Fully Automatic Oxygen Gas Control System 7 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 8 Oxygen Flowmeter with Humidifier 9 Essentia medical gas flowmeters are designed to measure and regulate flow.These are calibrated to specific gas & flow range. Oxygen flowmeter is intended for use with various delivery system when bubble/ micro bubble humidifier is attached downstream. These flowmeters are widely used in home care, health centers, district/ general/ regional hospitals, tertiary care, emergency vehicles etc. for administration of supplemental oxygen through nasal cannula, simple face mask,partial rebreathing mask, non re-breather mask, resuscitation mask etc. A passive process to humidify dry therapeutic gas (Category 3 Humidification) Micro Bubble Humidifier for Respiratory Therapy Patient connection port : Tapered hose barb suitable for 6 mm inner diameter plastic tubingMicro bubbles through humidifier for efficient humidificationPossible to integrate into an oxygen concentrator, sleep apnoea therapy equipmentOptimal RH achievable at various flow settingsAutoclavable at 121°C (249.8°F) for 5 minutes (Minimum 5 autoclave cycles)Over pressure safety valveNon-heated and reusableInlet connection port : DISS female adapter with chrome plated Brass nut embedded in ABS for hand-tighteningFlow : Up to 15 lpm @ 4 bar (58 psi)Construction material: Polycarbonate - shatter resistantCapacity - 240ml at max water level (Jar 450ml)Make- Altos/Aktiv or Equivalent 10 Emergency Oxygen Manifold 11 The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 6 cylinders in each Bank (means 6+6) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Make- Altos/Aktivor Equivalent 12 Fully Automatic Oxygen Gas Control System 13 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 14 MEDICAL NITROUS OXIDE SYSTEM 15 Nitrous Oxide Manifold 16 SITC of 4 + 4 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders.. as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 17 Fully Automatic Nitrous Oxide Gas Control System 18 SITC of Fully Automatic Control Panel for Nitrous Oxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel. It should fully complies and meets with the requirements of the NFPA-99 standards. It should be UL or ETL Listed. The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 19 Emergency N2O System 20 SITC of 2 Cylinder Emergency Nitrous Oxide manifold with All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders using a high flow Preset Pressure Regulator as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 21 MEDICAL CARBON DIOXIDE SYSTEM 22 CARBON DIOXIDE SYSTEM 23 The CO2 cylinder manifold should comprise of two cylinder Banks which can accommodate 4 cylinders in each Bank (means 4+4) for cylinder valves conforming to IS 3234 (CO2@ service) complete with copper tail pipes with fittings. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Nitrous Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves.High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Each manifold should be provided with one terminal header and a NPT connection for the Automatic control panel. Make- Altos/Aktiv or Equivalent 24 Certifications: ISO 13485:2016,ISO 9001:2015, CE 25 Fully Automatic Carbon DioxideGas Control System 26 SITC of Fully Automatic Control Panel for Carbon dioxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel.The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Micro processor controlled switch-over is accomplished automaticallyAutomatically resets itself for next cycle when depleted bank is replenished. No manual resetting requiredDigital pressure indication for accurate readingPressure unit options: bar, psi & kg/cm Status indicatorsPressure Stabilizer for stable discharge pressure & flowVisual & Audible signalDesigned to suit CO2 for gas specific usageOptimized residual gasMake-Altos/Aktiv or Equivalent 27 Emergency CO2 System 28 The Emergency supply manifold shouldbe connected to downstream of the manifold control panel.The assemblyshould consist of 2 (two) cylinders connection supplying a manually adjusted regulator via a common header assembly. The delivery system is isolated from the main system by an isolation valve. Pressure gauges should indicate cylinder and delivery pressure & valves conforming to ISO 13485Make- Altos/Aktiv or Equivalent 29 MEDICAL VACUUM SYSTEM 30 SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION 31 Vacuum Pump : The arrangement should consist of 2 nos. of oil lubricated imported rotary vane vacuum pump. Each vacuum pump should have capacity of 5000 lpm with IEC Motor rating of minimum 10 HP @ 50 Hz or above. Vacuum pumps shall comprise of air cooled, oil lubricated rotary vane vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525 mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed. The Vacuum Pump should be air cooled and oil lubricated rotary vane vacuum pumps designed for use in the field of high quality vacuum. It should be a robust construction, reliable operation, highly resilient carbon composite fiber vanes, Gas ballast valve. The pump should be having a 4 barriers system that avoids any oil leaks by doubling the 2 lip / shaft seals. Pump vanes shall be lubricated by a fully re-circulated and filtered lubricant supply. Also Pump design should include a lubricant separation system integral to the pump exhaust box consisting of no less than four stages of internally installed lubricant and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, lubricant mist elimination, smoke elimination, synthetic lubricant baffle, and shall be capable of removing 99.9 percent of all lubricant and smoke particles from the exhaust gas stream. The unit should have extremely low vibration as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- multitech/hitachi/Anistaiwata or Equivalent 32 Vacuum Tank of 5000 liters water capacity.Make- multitech/hitachi or Equivalent 33 Bacterial Filter:Vacuum Filter (Bacteria Filter) of 100 cfm to 105 cfm – 3” Filter housing with drain flask.: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards.The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplest, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969. The Vacuum filtration efficiency should be in excess of 99.9999% as per HTM0201 & AS 2896 standards. The high efficiency medical grade filter element should have custom engineered filter media and deep pleat element technology provides minimal pressure loss and filtration efficiencies. It should have advanced filtration technology for Low pressure loss borosilicate glass microfiber-media and open cell reticulated foam pre-filtration layer captures particulates, bacteria and liquid aerosols reducing energy consumption and overall system costs. It should have corrosion protection Internal and external electrophoretic painting followed by a tough exterior polyester powder coating.It should have easily removable sterilisable drain flask and differential pressure monitor gauge. It should have push fit element design for quick and easy maintenance with unique push fit element design. It should have element end cap color black. It should have maximum temperature 60 degree centigrade (140 degree F). It should have element of E31140MV grade. It should have pipe size connection 1” = 105scfm and 180nm3/hr FAA. It should have pressure loss clean & dry = < 3kPa (30m/bar/0.44psig). It should have maximum working pressure 0.5barg(7psig. It should have manual drain valves and 250ml sterilisable glass drain flasks.(Maximum tolearance allowed will be only 10%).Smooth mobility.Sturdy trolley mounted on 5 castor base wheels.Operational when connected to centralized vacuum.Fast connection to the vacuum source.Various Vacuum Connector options.Controllable & Stable vacuum for procedure.Step-less vacuum regulation within the range.Gauge needle with anticlockwise movement .Vacuum trap with bacterial filter in series to protect.system networkDisposable hydrophobic filter element.Quick hassle-free replacement of bacterial filter.Switch toselect collection jar & quicksuction shut-off.Easy access to selector switch.90 degree angular interface connectors to push-fit catheters.Autoclavable Polycarbonate collection jars.Overflow prevention trap on each collection jar.Make- Tridentor Equivalent 34 Ward Vacuum Unit with Regulator, Collection Jar of 1000 ml with Bracket.Make- Altos/Aktiv or Equivalent 35 Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 4000 ml Polycarbonate.Make- Altos/Aktiv or Equivalent 36 Bacteria Filter (Plastic) for 100 ml Safety Trap before Vacuum RegulatorMake- Altos/Aktiv or Equivalent 37 COMPRESSED AIR SYSTEM 38 SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION 39 Oil Free Scroll Air Compressor: The arrangement should consist of 2 nos.oil free scroll air compressor. It should be rated for 50 Hz, 3 Phase, 415 VAC power supply. Motor rating of each compressor should be 22 Kw & 30 Hp. Each scroll compressor should have a flow capacity of minimum 73 cfm (2070 LPM). The scroll air compressors shall be air cooled. Compressors shall be oil free scroll compressors suitable for both continuous and frequent start/stop operation having outlet pressure control range of 800 to 1000 kPa (8 to 10 bar). Each compressor shall have at least two individual scroll elements. The air quality shall be 100% oil free, certified ISO8573-1. The compressor shall have a sound insulating enclosure. Each scroll air Compressor should have an element consists of a fixed scroll shaped housing and a scroll shaped rotor. Air enters the compressor element through inlet opening. Once the air is drawn in, the orbiting scroll seals the inlet opening and forces the air into a continuously decreasing space. As scroll keeps orbiting, this process of compression is constantly repeated, resulting in discharging of oil free compressed air through outlet opening. Air is drawn through air filter and should be compressed by the compressor element of each compressor module. The compressed air is discharged via the check valve and a common air cooler. The cooling air is blown over the compressor element via a duct. A separate electric fan provides cooling air for the common air cooler. Each set of compressor modules has its own common aftercooler with an electric fan. The separator on compressors without integrated dryer has an automatic condensate outlet and a manual drain valve. The air compressors with integrated dryer, the dryer is equipped with a trap with an automatic condensate outlet and a manual drain valve. Each compressor element is protected by a sensor in the outlet pipe. The sensor is connected to the electronic regulator. Make- multitech/hitachi/Anistaiwata or Equivalent 40 Air Receiver of 5000 Liter Water Capacity (designed to withstand pressure of 10 Bar) with Auto Drain ValveMake-multitech/ hitachi or Equivalent 41 Medical Breathing Air Dryer- 375 SCFM - Medical air dryer heatless with purification modules are intended to provide a continuous supply of medical quality air conforming to the European Pharmacopoeia medicinal air monograph (ref. 1238), for respiratory use in healthcare facilities. The system shall be duplex such that the supply is maintained in single fault condition. Medical compressors shall be provided such that the specified volumetric flow is achieved without standby or backup systems running. Purification Module : The duplexed filter and dryer module shall incorporate high efficiency oil coalescing filters, heatless regenerative desiccant dryers, activated carbon filters and bacterial filters. The performance of the filters shall be according to below specifications: Oil coalescing high efficiency filter: mass efficiency of 99,92%, tested according to ISO 8573-2 & ISO 12500-1; Activated carbon filter: max remaining total oil content of 0,003 mg/m³, tested according to ISO 8573-5 & ISO12500-2;Bacterial filter: particle count efficiency of 99,98% at MPPS=0.06μm, tested according to ISO 12500-3. Dryer Purge Control : The dryer control system shall incorporate a Purge Saver Energy Management system that freezes the regeneration of the desiccant once adequate dew point is reached in the inactive tower. Only when the dewpoint level in the active tower deteriorates to an unacceptable level will the intelligent controller switch towers.Coarse coalescing filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of red color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 1 micron. It should have maximum particle size class 2 micron as per ISO 8573-1: 2010 . It should have maximum oil content 3 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68 degree F (20degree centigrade) = 0.3ppm (0.3mg/m3). It should have pressure loss clean & dry = 0.8psi (55m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). 42 Fine coalescing filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of blue color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.01ppm (0.01mg/m3). It should have pressure loss clean & dry = 1.2psi (85m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). Activated Carbon Filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of black color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.003ppm (0.003mg/m3). It should have pressure loss clean & dry = 1.7psi (115m/bar). 43 Fine Dust Filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element blue color end caps for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have pressure loss clean & dry = 1.5psi (100m/bar). Make- Trident or Equivalent 44 Pressure Reducing Station for 4 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 4 bar for medical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 4 bar stations - 5.5 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 10000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 45 Pressure Reducing Station for 7 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 7 bar for surgical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 7 bar stations - 9 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 4000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 46 SITC of Medical Gas Outlets- 47 Probes are crucial for gas specific and stable connection. These are used to connect medical gases and vacuum devices to outlets / terminal units of MGPS distribution network.Make- Altos/Altos/Aktiv or Equivalent 48 FeaturesSmooth quiet action.Safe keying configurations.Gas specific ISO 32 colour coding.Firm locking of connector / probe.Strong, positive and secure connection.Corrosion-free and material compatibility.Reliable and safe dispense of gases & vacuum.Pipe stub end flared to align drop pipe and to avoid butt joint. 49 Oxygen 50 Air-4 51 Air-7 52 N2O 53 AGSS 54 Vacuum 55 CO2 56 Certifications:ISO 13485:2016 – Medical devices,ISO 9001:2015 57 MISCELLANEOUS ITEMS 58 SITC of Common Electrical Control Panel for Compressed Air System, Vacuum System & AGSS as per requirementcomplete with plant room wiring. 59 SITC of Degreased Medical Grade Copper Pipe as per EN 13348 :2018. BSI Kite Mark certified. CE Certified. Third Party Inspection by TUV or Lloyds Registrara AsiaMake- Altos/Altos/Aktiv or Equivalent 60 Installation of piping should be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards should be used . Pipe fixing clamps for upto 28mm diameter. Pipes should be non ferrous suitable for the diameter of the pipe. For the pipes of the sized above 28mm rigid metallic hanging or cemented supports to be used. 61 The main lines to the building to be taken overhead through metallic poles or through underground ductswith inspection removable slabs,All pipe joints should be made using inert gas fluxless brazing method.Alljoints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation ofcopper oxide on the inside surface of the joint.All pipes should be installed without springing or forcing.All pipes shouldprotected against mechanical injury in a manner satisfactory to authorities havingjurisdiction. 62 Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas.Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours. 63 Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per international standards.All concealed pipes to have gas identification bands / labels at appropriate distance.Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. 64 Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS: EN 13348. 65 All copper pipes will beUL certified for medical use before dispatch and the pipe will be delivered plugged or capped at both ends. 66 108 mm OD X 1.5 mm thick 67 76 mm OD x 1.5 mm thick 68 54 mm OD x 1.2 mm thick 69 42 mm OD x 1.2 mm thick 70 35mm OD x 1.2mm thick 71 28 mm OD x 1 mm thick 72 22 mm OD x 1 mm thick 73 15 mm OD x 1 mm thick 74 12 mm OD x 0.7 mm thick 75 SITC of Medical Gas Digital Area Alarm System 76 Microprocessor based digital LCD alarmHighly visible 7 (178 mm) LCD screenPressure sensing through piezoresistive sensing technologyAlarms can be monitored audio-visualTouch screen operationComprehensive monitoring of all the medical gas alarm panelsData display at a central monitoring station Features-Alarm status will be visible through ethernet port on master alarmPressure Equipment Directive 2014/68/EUDigital Flow Care Alarm Management of Medical Gas Pipeline SystemReal time updating of statusOperational parameters i.e. high and low level canbe set “in-situ” to suit requirement in an area 2Programmable pressure unit display (bar, kg/cm & mmHg)Audio mute optionDesigned to serve 2, 3, 4, 5 & 6 gases including VacuumNIST connection for Gas inputPowered by 220V AC to 24V DC external adapterMake-Altos/Aktivor Equivalent 77 Conforms to: IS / ISO 7396 - 1 : 2016 + A1 : 2017HTM 02-01 Part A, IS / ISO IEC 60601 - 1 : 2015 + A1 : 2020Certifications:ISO 13485:2016 – Medical devices – Quality Management SystemsISO 9001:2015 - Quality Management Systems 78 6 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar, Vacuum & CO2) 79 5 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar & Vacuum) 80 4 - Gas (O2, N2O, Med Air-4 Bar & Vacuum) 81 3 - Gas (O2, Med Air-4 Bar & Vacuum) 82 2 - Gas (O2 & Vacuum) 83 SITC Of Area Valve Service Unit with Valve & Gauge 84 The importance of full bore ball valves is to reduce pressure drop to almost negligible in the pipeline distribution system so that the designed pressure is available at the outlet point. Ball Valves are used to start or stop a flow. In Medical Gas Pipeline System (MGPS), the valves are normally kept open i.e. allow the gas to flow unless it is required to shut-off the gas supply for scheduled maintenance or emergency situation 85 Features-Operational parameters can be set in-situDigital pressure unit display options -psi / bar or kg/cmDigital & illuminated LED display of “Normal”, “High” & “Low”Microprocessor based moduleHighly accurate “Heavy Duty” pressure transducerPowder coated aesthetically designed enclosureEnclosure separable from the base for ease of installationReusable lock assemblyAudio mute optionPED: 2014/68/EU certified full port Ball Valve (PN 30)Long extension copper pipes to connect MGPS networkFront door opens up vertically for comfortable accessDesigned to serve 2, 3, 4 & 5 gas moduleSuitable for all medical Gases & VacuumMake- Altos/Aktiv or Equivalent 86 6 Gas Service (O2, N2O, Med Air-4 Bar,Air-7 Bar, Vacuum & CO2) 87 5 Gas Service(O2, N2O, Med Air-4 Bar, Air-7 Bar & Vacuum) 88 4 Gas Service(O2, N2O, Med Air-4 Bar & Vacuum) 89 3 Gas Service (O2, Med Air-4 Bar & Vacuum) 90 2 Gas Service(O2 & Vacuum) 91 SITC of Degreased Medical Lockable Ball Valve with Pipe line assembly 92 Pre piped single port) for size upto 2 (for 54mm copper pipe): Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It shouldbe blow-out proof stem. It should be lockable valve. The Valve shall be 3 piece ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton for 1/2” - 4” valves. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa].Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Valves shall be designed in such a manner that it can be “swung-out” during installation so as to prevent damage due to heat transfer during the brazing operation. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation.Make- Altos/Aktiv or Equivalent 93 12mm 94 15 mm 95 22 mm 96 28 mm 97 35mm 98 42 mm 99 54 mm 100 108mm 101 SITC of Bed Head Panel aluminum powder coated with mininum 3 channel and 3 duct with separate partition rows and built in aluminum railMake- Altos/Aktiv or Equivalent 102 Bedhead panel for Low Equity Ward Areas, 1500mm length, with provision of Gas outlets & provided with electrical sockets & accessories complete 103 Horizontal Bed Head Panel – For 2 Gas Service (Oxygen & Vacuum) 104 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, Med Air-4 Bar & Vacuum) 105 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, N2O & Vacuum) 106 Horizontal Bed Head Panel – For 4 Gas Service (Oxygen, N2O, Med Air-4 Bar & Vacuum) 107 Special FeaturesInnovative design – Efficient, simple & accessibleVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outlet 108 Application AreasInnovative design – Efficient, simple & accessiblityVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outletAdult in-patient wards/ General WardsResuscitation RoomsPost-anaesthesia areaEmergency Admission WardsDialysis Stations 109 Configuration : 5 Outlets & 6 Multi Standard 220V AC sockets, 1 each RJ11 Telephone socket & RJ45 Data Socket and provision of protective earth (Earthing) 110 Modular Operation Theatre (Part-B) 111 WALL AND CEILING MODULAR PUF PANEL 112 The panels shall be made of durable and uniform material that shall be easy to clean and extremely hygienic. Operation theatre shall not have any sharp edges, corners and shall not support bacteriological or fungicidal growth and shall be resistant to most chemicals, commonly used in Hospital Departments. Joints in the panels in the operation theatre shall be sealed. The function of sealing shall assure an airtight environment in the room and eliminate services to prevent dust accumulation.PUF Panel with an overall thickness of 50 mm for wall and 30 mm for ceiling, made of 0.8mm (make-Tata/jindal)GI Front sheet and 0.6mm PPGI back wall with infill of PUF at 40 kg/m3 (40D)which is necessary for mechanical strength. Panels shall be mounted on a structure made of galvanized steel and shall enable the distribution of medical gases, electricity, sewerage inside the wall.PUF Panel as above has better thermal efficiency and thus saving on energy cost. Proposed system shall be installed at site without any welding.The partitions shall not have corners; adjacent surfaces shall be molded flush.Upper wall element shall have sufficient height to reach the lower edge of the prefabricated ceiling. All the sharp edges and corners should be chamfered to avoid bacterial contamination.The individual ceiling panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed,provides a seamless sub-structure, which is then sanded smooth finished with Metal Putty and then painted using imported anti-fungal paint to give a smooth, non-porous seamless finish and without corners by providing coving on floor as per standard.It is resistant to chemicals used in Operation Room for moping and fumigation repeatedly.Make-Jindal/Tata or Equivalent 113 WALL AND CEILING MODULAR PUF PANEL-SS304 114 The prefabricated Operating Room should be of SS Sandwich as per its latest standards. SS Sandwich : It should have at least min. 0.8 mm 304 Grade Stainless Steel on front side and 0.5mm PPGI back side . The sandwich panel shall have a core consisting of rigid polyurethane foam, injected under high pressure, with a minimum density of 40 kg/m3. Cladding structure insulated stainless steel wall panels with total panel thickness 50 mm for wall and 30mm for ceiling.The individual wall panels shall use tha tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler and sanded flush. Stainless steel plate finished to fine grain surface, treated properly to take antifungal paint panelingshould be easy to maintain, durable, antistatic / conductive and fire retardant. Clearance between inner panel and outer wall should be sufficient to allow the maintenance personnelfor service. This closed space should be flushed continuously to eliminate dust and bacterial accumulation.It should have minimum number of junctions. The junction should be seamless and should be sealed with suitable sealants. Third party test certificate for SS from material testing lab. (Govt. authorized)required.Make-Jindal/Tata or Equivalent 115 ANTI-FUNGAL PAINTING 116 Anti microbial Paint for Different Areas antibacterial Paint on wall and ceiling panels Inside OT work.Anti-Microbial Protection: These product hygiene coatings start the biocidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years.Minimum three coats of Anti Fungal/Bacterial Paint, glaze or equivalent to a minimum dry thickness of 300 microns to give smooth , non-porous finish without any corners.It will also be resistant to the chemicals used in Operation Room for Moping & Fumigation repeatedly. This Hygiene coating are independently tested by leading universities to demonstrate resistance.Make-SKK/ Jotun or Equivalent 117 PLENUM LAMINAR AIR-FLOW 118 Supply and installation of Plenum LAMINAR FLOW- Plenum Box Ceiling mounted systemwith unidirectional airflow, SPECIFICATIONS-PLENUM UNIT - The complete unit factory designed and manufactured with proper air-sealing. It seamlessly integrates with OT ceiling mounted equipment.Plenum size- 2400 x 2400mm with aluminium material.Diffusers are made of SS304 punched/perforated sheet for unidirectional diffusion air. The complete unit factory designed and manufactured with proper air-sealing.It seamlessly integrates with OT ceiling mounted equipment.The material used is non-corossive as per standard guidelines such as Aluminium.Make-Jindal/Tata or Equivalent 119 Hepa Filters- 120 The filter hosing on either side houses provided with HEPA minipleate H13/H14 filters.The system has a reliable filter efficiency, filters are designed to remove particles and germs with the use of H13/H14 filters retaining 99.97 % of the particles and germs.Frame : Aluminium Mini Pleat Size- 610x610x125mmMOC of the Media : Micro Fibre Glass micro drawn grid Separators : continuous Gasket: Food GradeMPPS average efficiency: > 99.95% 3 Micron D Efficiency: 99.97% down to 0.3µ.Maximum Operating Temp : 60 degree CelsiusMake- Thermadyne or Equivalent 121 ANTI-STATIC VINYL FLOORING: 122 SupplyandinstallationofImportedVinylFloor:SeamlessantistaticconductiveESDvinylflooringsystem,2mmthick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting.SPECIFICATIONS:- Flooringinoperationtheaterroomwii beseamless withperfectly curvedflash-covings,resistance tomechanicalstressanddynamicloadsandhavingESD/EMI(Conductive)protectioncharacteristics,2mmthick, washablevinyl.Flooring is a static-conductive,flexible homogeneousvinyl floor covering withan electricalresistance of 5x10^4 123 SELF LEVELLING MATERIAL. 124 The SLC should be of Portland cement-based, It should be self-leveling underlayment formulated with a special blend of polymersusedtolevelandsmoothinteriorconcrete,terrazzo,ceramicandquarrytile,epoxycoatingsystems,metal andnon-watersolubleadhesiveresidueonconcretepriortotheinstallationoffinishedflooring–on,aboveorbelow grade.TheSLCshouldprovideadurable,flat,smoothfloor surfacewithminimumlabor andinstallationtime.Itshould be pourable or pump-able when mixed with water and should seek its own level to produce a smooth, flat, hard surface. 125 OPERATION THEATRE CONTROL PANEL: 126 Supply and installation of Membrane type 6 services OT control panel , with distribution box mounted flush in the theatre wall, comprising of the following:The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations.The room Surgeon’s control panel should be modifiable with changing technology& equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose.he panel should be “Membrane” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance membrane with sterilization feature.The Panel should contain 6 or 9 service tiles as below:1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System.4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller.7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters.Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digitaltype & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre.The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures.A hand free set Telephone System should be incorporated in the panel with memory type card.The control panel should be designed for front- access only. All internal wires should beMake- Altos/DGline or Equivalent 127 Distribution Board outside OT 128 Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house the operating transformers, light control relays, electrical distribution equipment and circuit protection equipment for all circuits withinthe operating theatre. All internal wiring should terminate in connectors with screw mounted, on a DIN rail. Individual miniature circuit breakers will protect all internal circuits. All high voltage equipment should be installed in a separate enclosure.All internal wiring should terminate in connectors with screw & clamp springConnections of the clip- on type mounted, on a CE/ / ICMED9001/ ICMED13485 approved rail & labeled with indelible proprietary labels.Individual fuses or miniature circuit breakers should protect all internal circuits. 129 LED PERIPHERAL/GENERAL LIGHTS: 130 Recess mounted sealed IP54 Protocol, non-hygroscopic peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED, with optical anti- glare system for individually adjustable light distribution.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated steel frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Control equipment for the general lighting and the light dimming should be provided in the theatre Control Panel.Make-Altos/DGline or Equivalent 131 LED X-RAY VIEW PANEL: 132 TwoPlateX-RayViewScreenwithflickerfreeilluminationhavingimportedLEDsystemforuniformilluminationand operated by X-ray film .Thesystemhavingelectricalsafetycodesforhigh&Lowvoltagesystem.Itshouldbedesignedtoprovideflickerfree luminance for the film viewing purpose.It should be installed flushed with the theatre wall for hygiene and ease of cleaning.Make-Altos/DGline or Equivalent 133 MAGNETIC LISTING WRITING BOARD: 134 MagneticWritingBoard of size940x 640x50mmcomprisesof aflushmounted,1.50mmthick,whitelaminate board, bonded toa 10 mm high density fibreboard sheet for additional rigidity.The writing unit should comprise of flush mounted white laminate board, be opened to create a wall mounted writing surface within the operating room. The white board should be constructed from white laminate board.Make- Altos/Dgline or Equivalent 135 AUTOMATIC HERMETICALLY SEALING SLIDING DOOR -1500mmX2100mm 136 Automaticoperated Hermettically Slidingdoor with High Pressure Laminate on both side, Door size (1500mm wide2100mmheight)completewithdoubletoughnedglassvisionwindowof300mmx300mm withinanaluminum extrusionhighqualityframecompletewithrequiredaccessories.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings that are adjustable during installation to ensure sealing.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door HandleMake-Metaflex/Doormedor Equivalent 137 HERMETICALLY SEALING HING DOOR-900mmX2100mm 138 Manually operated Hermettically Semi- sealed Hing door with HighPressure Laminateon bothside, Door size (900mm wide x 2100mm height) complete with double toughned glass vision window of300mm x300mm andsmooth effortless doorcompletewithrequiredaccessories,fixedfirmlytothewall.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be hinge mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door Handle. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door.Make-Metaflex/Doormed or Equivalent 139 CORNER GRILLS 140 Aluminium corner grills are used to air exhaust at all four corners.size of grill will be 600mmX400mm.Duly powder coated extruded aluminium linear horizontalfixed bar with normal 15 deg. blade having pitch of 13 mm.Exhaust Gril for return air-The exhaust air cabinets should be openable and cleanable. These cabinets should have suction from bottom.Distribution of exhaust air volume should be divided between fluff strainers to maintain the required pressure within the theatre without causing turbulence.The Exhaust air cabinet should be manufactured and supplied by the supplier of wall and ceiling system supplies. Also it should match perfectly with the ceiling system aesthetically.Make-conair/Bala ji engineering or Equivalent 141 ALUMINIUM DUCTING: 142 Aluminium Ducting ( 22 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication.Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart.Thermal insulation with 9/13mm XPE with aluminium foil for supply & return air ducts.Joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 6 meter.SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc.Make-Hindalco/Virgo or Equivalent 143 AIR HANDLING UNIT 144 AHU System & Condensing Unit with consistingDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GI Frame Work Hollow Extruded AL Profile Thickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material ofDrain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base Channel DX COIL: Make Of Coil ZECO Coil Casing / Blank offs GI Material Of Tube Copper (IGT) Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material Copper Thickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12 FILTERS: Media of Filters Synthetic (non woven type) Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron FAN & MOTOR: Fan make Nicotra Motor make CG Motor type TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor VFD: VFD make DELTA DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE:(WITH 25MM THICK PANEL) ◻ Mixing box with manually operated FA & RA damper in GI constructionDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GIFrame Work Hollow Extruded AL ProfileThickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material of Drain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base ChannelDX COIL: Dx type coils having suitable number of distributors for connecting expansion valve with condensing unitsMake-Zeco//VTS or Equivalent 145 Make Of Coil Casing / Blank offs GI Material Of Tube Copper (IGT)Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material CopperThickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12FILTERS: Media of Filters Synthetic (non woven type)Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron VFD: DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE: (WITH 25MM THICK PANEL)Mixing box with manually operated FA & RA damper in GI constructions.Filter section with 50 mm thick (EU-4) box type pre filter with 305 mm thick (EU-5) bag type fine filter mounted on common filter frameCoil section with 6 row deep DX cooling coil with suitable distributor. Heater Section with GI strip Heater.Fan section with SISWbackward curved plug fan & Motor (IE-2). Manually operated SA damper in GI construction.Tonnage TR 8.5 Air Qty (CFM) 3500SP (mm wg) 125 UnitFan Type Plug Fan-355Fan model RLC E6-3135-23-19 Fan RPM 3400Motor RPM 2880Shaft Absorbing Power 3.2 Motor Rating (kw) 3.7 Motor pole 2Coil area (Sq.Ft.) 7.0 DX Cooling Coil RD 6 Distributor 1Heater KW3Filter area (Sq.Ft.) 8.0 Length (mm) 2500Width (mm) 1400 Height (mm) 945 146 AIRCONDITIONING: (8.5 T AC ) 147 Nominal Cooling Capacity-8.5tr,102000Btu/hr,29894watt Nominal Air Quantity-6250CFMPower Supply (V-ph-Hz)-400 ± 10% -3-5 Fan-PropellerDischarge-HorizontalFan Motor-Permanent Split Capacitor Type Power (watt)-470Control Type-LED DisplayOverall dimensions (mm)-982 X 610 X 1100 mm- Compressor- Scroll CompressorRefrigerant-R-410A (5.6) Liquid Line-5/8Suction Line-1-1/8Make- Carrier or Equivalent 148 ELECTRICAL WIRING INSIDE THE OT 149 Electrical Wiring as per requirement of OT, Wiring With OT distribution electrical Panel. ( Power cable at OT with Main distribution Panel will be provided by customer) Operation theatre shall be installed in the remote cabinet.All electrical wiring should be terminated to the connectors mounted on DIN/CE approved rail and labeled with indelible labels.Individual fuse and miniature circuit breakers should protect all internal circuits.Complete schematic diagram drawing description should be enclosed with the equipment. Makes:Scheinder/PolyCab/ Schematic.Supply, Installation, Testing and Commisnoing of Electrical Distribution Board with required MCB : It should be installed in a separate enclosure.Transformers,Mains,Relays,Circuitprotectiveequipment,forallcircuitsofOperationtheatreshallbeinstalledinthe remote cabinet. 150 MEDICAL GAS PIPE-LINE SYSTEM INSIDE OT 151 Medical Gas Pipe Line inside the OT above ceiling as required, complete with valve box and other required fitings. Medical Gas copper pipeline inside the OT and the Provision to connect to Pendant Systems (inside OT only).It should be confirm and meets with BS:EN:13348:2008 copper pipes.All medical grade degreased copper pipes must be inspected and duly Third Party Certified by Lloyd’s Registered Asia. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW024A (Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2008 & 250 or 290 (Half hard).Degreasing of pipe shall be such that there is less than 20 mg/m2(0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS:EN:13348:2008.Make- Altos/Aktiv/Mandev tubes/Mehta tubes or Equivalent 152 PASS BOX SIZE-2FTX2FTX2FT 153 Pass Box to remove the waste materials from the Operation Room to the Dirty Linen Area. Each box is equipped with two doors and the door should be operated electronically.. It is designed in such a way that only one door can be opened at one time. UV light is so installed that it is kept on while both the doors are closed and turned off automatically when the doors are opened. Indicators on both side of the Operation Room for Door Open/Close status. It is made of SS-304 Grade.Make- Jindal/Tata or Equivalent 154 STORAGE UNIT 155 Storage Unit of size 850x1600x350 mm has made of 1.6mm galvanised steel sheet. The exterior glass doors has lockable with magnetic push-button for easy opening. Removable toughened glass shelves of thickness 5 mm will be provided with the storage units.Make- Jindal/Tata or Equivalent 156 Pressure Relief Dampers 157 Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areasCounter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room.Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance.The PRD should remain closed at pressure below the set pressure and should open fully at a pressure only fractionally above the threshold pressure.The body of PRD sleeve and Grill should be epoxy powder coated as per standard High grade SS304 Stainless steel plate should be used for body and for bladesMake- Jindal/Tata or Equivalent 158 OT Pendant –Single Arm Anesthesia(Modular) 159 Anesthesia Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.Make- Altos/Aktiv or Equivalent 160 The Pendant Service Heads / column should be supplied with medical gas terminal units. The medicalgas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard. 161 Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 2 no, Air (4 Bar) – 2 no, Vac – 2 nos, AGSS – 1 no. Medical rail with brake buttons fitted. - 1 No.Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its lengt 162 OT Pendant -SURGICAL PENDANT : 163 Surgon Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.The Pendant Service Heads / column should be supplied with medical gas terminal units. The medical gas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard.Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 1 no, Air (4 Bar) – 1 no, Vac – 2 nos.Medical rail with brake buttons fitted. - 1 No.Make- Altos/Aktiv or Equivalent 164 Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its length. 165 UV LIGHT INSDIE OT FOR CLEAN/STERILIZE PERPOSE SIZE-2FTX1FT 166 Recess mounted sealed IP54 Protocol, non-hygroscopic UV peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED. Ultraviolet (UV) lamps are commonly used in operation theatres for disinfection.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Make- Altos/Dgline or Equivalent 167 Surgical Scrub Station – Two Bay 168 Compact surgical scrub sink should be designed for use in OT complex providing for pre – OT scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel and should be seamless welded construction, polished to a satin finish.The washing faucet shall be made of Chrome plated brass hand. The station shall be equipped with soap dispensers made of SS 304 grade.The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers.Hands free operation should include infra red sensors with built-in range of adjustment.The scrub station shall be made of high-grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971.Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of 1,3,6 & 10 min should be available. This timing should be adjustable to meet individual application requirements.All units should have reduced anti- splash fronts.The scrub stations control system shall be based on advanced microprocessorThe scrub station shall be sensor-activated 24VAC and should have the provision to operate it manually in case of power failure by using foot switch or knee switchimported thermostatic mixing valve for Hot & Cold water, Strainers, Spouts & manual foot operated valve system.Make- Jindal/Tata or Equivalent 169 AUTOMATIC PHASE SEQUENCE CONTROLLER 170 PMC Based (Pre magnetic Contractor)63A Double interlock & time Delay systemAuto/Manual Operation Sie- 140 x 275 x 320 mm Smooth and fasr Switchingworks well even at high & low voltages. Wide Current rnge.Voltage Range-130-280Vac Temperature- 55 Degree Celsius Auto mode Selector switchDigital micro Control relay for sequence management.LED Indicator for complete status of power.Make- Subtech or Equivalent 171 Operation Theatre Light - LED type, Camera Ready (Triple Arm) 172 Operating Room Surgical Lighting system should provde an ideal combination of broghtness, maneuverability, and shadow resolution without sacrificing color accuracy throuh a consistent LED technology. Such Lighting System should have the following technical specifications: 173 a. Number of light heads : Two per suspensionb. Colour Temperature range : 3800k-5000 (±10%) - Variable color temperature. c. Field Size Diameter : 20 to 28 cm (+/- 10%)d. Working range : 750 to 11100 mm (+/- 10 %)e. Illumination Level : 160000Lux (major Dome & Minor dome )f. Rotation : 360 - 330 degree g. Sterilizable Handle : 02 Nos h. Mounting type : Ceiling i. Supply Voltage : 230 VAC 50 Hz j. Bulb Type : LEDk. Dimming Range : 50% - 100%l. Operating / Storage Humidity : 10 - 95 %m. Life of Light source : > 40,000 Hrs n. Should be provision to mount the camera in 1 dome . o. Surgical Light System Should be compliant with relevant European CE / US FDA standardsMake- HillRom/Steris orEquivalent 174 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
39.
Housing Urban and Rular Development #9334202 Technical Bid
Tender For Repair Of Newly Allotted Eye Operation Theatre Ot Of Gmch Jammu.- 1 Replacement of damaged LED Peripheral Lights in false ceiling of size 2X2 with light Intensity 50000 Lux. The job includes shutting off the power supply to the unit andremoving the damaged LED Peripheral lights from the ceiling and providing and fitting of new LED Peripheral lights 2X2 with light Intensity 50000 Lux. Complete job includes the cost of cost of material, taxes andlabour charges, transportation charges etc 2 Repair of the surgeon control panel installed in Newly allotted Eye OT in GMCH Jammu by adjusting of high & low voltage system, wired to the current IEEControl Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Membrane” type; configured to incorporate all the services that operation room staff requires. The job includes repair/adjustment of Time Day Clock, Time Elapse Day Clock, General Lighting System ,Medical Gas Alarm Panel , Hand Free Telephone set with memory, Temperature & humidity indicator with controller,HEPA Filter Status module. , Room Pressure Indicator Music control. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters. Central Lighting system should incorporate all the necessary controls of the lighting. System inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification. 3 Supplying and fixing of modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate having 03 No’s of 6 pin 15/16 A socket outlet and 02 No’s of 15/16 A switch( Single way) The job includes disconnecting the old damaged switches from their installed positionsand then connecting/fitting the new ones in position. Complete job includes the cost of cost of material, taxes andlabour charges, transportation charges etc. 4 Repair of the damaged hermatically sealed sliding door by replacing its damaged Flush mounted sealant rubber with sterile jointing systems. Replacement of damaged false ceiling by Providing and fitting of new calcium silicate false ceiling in 600 x 600 mm grid approx 100 sq ft. at the ceiling of the Newly allotted Eye OT in GMCH Jammu . Complete job includes the cost of cost of material, taxes andlabour charges, transportation charges etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
40.
Housing Urban and Rular Development #9334199 Technical Bid
Repair And Maintenance Of Operational Eye Operation Theatre Ot Of Gmch Jammu- 1 Replacement of damaged LED Peripheral Lights in false ceiling of size 2X1 with light Intensity 50000 Lux. The job includes shutting off the power supply to the unit andremoving the damaged LED Peripheral lights from the ceiling and providing and fitting of new LED Peripheral lights 2X1 with light Intensity 50000 Lux. Complete job includes the cost of cost of material, taxes andlabour charges, transportation charges etc 2 Maintenance/ Repair of the AHU of operational Eye OT of GMCH by shutting the water supply to the unit and repair by way of dismounting of old damaged blower from blower assembly , replacement of damaged blower by providing and fitting of new blower in place of damaged blower in blower assembly and 2 no’s new bearings as per sample, and testing on full load. The job also includes replacementof damaged bearings of AHU motor (15 HP) as per sample along with rewinding of the burnt stator winding and replacement of V beltsand08 No’s Prefilters of size 24”x24”x2” in place of damaged ones. Then making the connections of the unit and taking trial on full load .The job includeslaying of drainage line from the AHU to the nearest main drain by Providing and fitting of PVC pipe 32 mm dia 40 ft ,8 elbows,8 sockets and joining adhesive etc. The job further includes servicing and cleaning of Hepa Filter system cum laminar Air Flow system by cleaning it with fresh water spray gun and then with chemical cleaner. The job further includes replacement of 06 No’s of damaged Hepa Filters by providing and fitting of new Hepa Filters of 0.3 micronas per sample.the job includes cleaning of the Air duct by manual means from both the inlet and the outlet of the duct using special tools and tackles. Complete job includes the cost of cost of material, taxes andlabour charges, transportation charges etc. 3 Supplying and fixing of modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate having 03 No’s of 6 pin 15/16 A socket outlet and 02 No’s of 15/16 A switch( Single way) The job includes disconnecting the old damaged switches from their installed positionsand then connecting/fitting the new ones in position. Complete job includes the cost of cost of material, taxes andlabour charges, transportation charges etc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
47.
Educational and Research Institute #9025260 Technical Bid
Rate Contract For Supply And Installation Of Hepa Filters And Validation Of 25 Nos. Modular Rate Contract For Supply And Installation Of Hepa Filters And Validation Of 25 Nos. Modular Operation Theatre (Mot) At Aiims Rishikesh , Supply And Installation Of Mini Pleat Hepa Filter Flange Type With Media Packing Of 2 Inch, H 14 Grade, Efficiency 99.999% Down To 0.3?, Ipd 160Pa +- 10% & Fdp 500Pa, Moc: - Aluminium Anodized Extrusion Filter Media: - Glass Fiber With Hot Melt Separator With Both Side Gi Faceguard, Neoprene Gasket 5 Mm, Operating Temperature 70°C Size -305(Mm)X610(Mm)X69(Mm), 250 Cfm , Supply And Installation Of Mini Pleat Hepa Filter Flange Type With Media Packing Of 2 Inch, H 14 Grade, Efficiency 99.999% Down To 0.3?, Ipd 160Pa +- 10% & Fdp 500Pa, Moc: - Aluminium Anodized Extrusion Filter Media: - Glass Fiber With Hot Melt Separator With Both Side Gi Faceguard, Neoprene Gasket 5 Mm, Operating Temperature 70°C. Size -610(Mm)X915(Mm)X69(Mm), 750 Cfm , Supply And Installation Of Mini Pleat Hepa Filter Flange Type With Media Packing Of 2 Inch, H 14 Grade, Efficiency 99.999% Down To 0.3?, Ipd 160Pa +- 10% & Fdp 500Pa, Moc: - Aluminium Anodized Extrusion Filter Media: - Glass Fiber With Hot Melt Separator With Both Side Gi Faceguard, Neoprene Gasket 5 Mm, Operating Temperature 70°C. Size -610(Mm)X760(Mm)X69(Mm), 625 Cfm , Supply And Installation Of Mini Pleat Hepa Filter Flange Type With Media Packing Of 2 Inch, H 14 Grade, Efficiency 99.999% Down To 0.3?, Ipd 160Pa +- 10% & Fdp 500Pa, Moc: - Aluminium Anodized Extrusion Filter Media: - Glass Fiber With Hot Melt Separator With Both Side Gi Faceguard, Neoprene Gasket 5 Mm, Operating Temperature 70°C. Size -610(Mm)X610(Mm)X69(Mm), 500 Cfm , Validation Of 25 Nos. Mot (Each Mot With Hepa Filter – 6 Nos Of Above-Mentioned Size) As Per Iso 14644 Standards. Following Tests To Be Done: - 1. Temperature And Humidity Check 2. Non-Viable Particle Count 3. Air Change Rate Calculation 4. Air Velocity At Outlet Of Terminal Filtration Unit /Filters 5. Pressure Differential Levels Of The Ot With Respect To Ambient / Adjoining Areas 6. Hepa Filter Integrity Test (Using Pao) 7.Recovery Test 8. Air Flow Pattern Test With Videography (Using Water Fogger) 9.Light Intensity Measurement10. Sound Level Measurement
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
TenderDetail
Loading tenders