View Bid Results For Miscellaneous Finishes Tenders

We found 27 Bid Results related to miscellaneous finishes tenders. You can find Contractor details who won miscellaneous finishes tenders along with contract details in Bid awards announcements section.

Filters
Stage
24
2
1
Tender Publishing Platform
1
26
State / UT
15
4
3
3
2
2
2
2
2
1
1
1
1
1
1
1
Contract Value
3
1
10
13
Publish Date
0
0
0
0
0
Sector
8
16
3
2
2
1
1
1
1
Ownership
3
15
10
2
Within keyword
Active filters:
Showing 1–1 of 27 tenders matching your filters
1.
Defence #11104420 AOC
Tender For Repairs / Re-Novation Of Ofti And Ofti Work Shop Buildings Inside Factory Area At Ofmk.; 1 Site clearence 2 FELLING OF TREE: Felling of tree exc.30 cm and not exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site 3 GRUBBING UP TREE TRUNK : Grubbing up tree trunk of girth exceeding 100 mm and not exceeding 150 mm, including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable materials and removing of unserviceable materials to a distance n. exc. 50 m and clearing site. 4 Demolition of cement concrete of any description and in any position not otherwise specifically provided for.Complete all as specified directed. 5 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar. Complete all as specified directed. 6 Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified directed. 7 Dismantling floor,heartor wall tiling including cement mortar bedding but nor baking removing serviceable tiles to stores and rubbish off the premises.Complete all as specified directed and directed. 8 Taking down : Taking downcement or cement lime plaster, any description on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. 9 Removing building materials etc.other than spoilupto a distance of 1.0 Km, including loading, unloading and stacking at the destination. 10 Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar.Complete all as specified and directed. 11 Stone Masonry : Walling of Squared Rubble regular coursed Stonemasonry, well bonded, bedded and solidly hearted built in with 1:6 cement mortar, Complete in all respects as specified and directed. 12 Damp proof course to horizontal or vertical surfaces In cement concrete 1:2:4, type B-0, 40 mm thickincluding necessary formwork . 13 Flush Pointing with 1:4 cement mortar to square rubble, coursed, well bonded and solidly hearted built in cement mortar as directed. 14 Vitrified tiles : Supply and laying of Light shade vitrified tiles 10 mm thick (Square/Rectangle) polished , area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Floor tile finishglossy/mat/ antiskid will be as decided by EIC. Complete all as specified and directed . Make : Johnson, Orient bell, AGL as approved by EIC. 15 GRANITE : S&F Granite 25 mm thk (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed. 16 FLOOR TILING :Supply & fixing Coloured non skid ceramic tiles in flooring, 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell 17 SCREED BED : Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6. Complete all as specified and directed. 18 Plastering : Rendering of 10mm thick plastering with 1:6 cement mortar on fair faces of brick work or concrete surfaces. Complete in all respects as specified and directed. 19 Rounding to edges of stone slabs / granite one edge,such as in steps, cooking platform, and other similar situations. Complete all as specified and directed. 20 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc. complete as directed by EIC. 21 Taking down wooden wall panelling of any description and similar work as directed. 22 Snap grid : Supply and fixing of 605x605 mm snap gridGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners withand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediatechannel at 457 mm centre to centre. Complete all as specifiedand directed, Make : Armstrong 23 Supply and fixing of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 24 POP ceiling : Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mmwith 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately). Complete all as specifiedand directed, Make : Armstrong 25 Ceiling board : (M&L) S&F Exposed metal frame ceiling with calcium silicate boardof siliceous and calcareous material reinforced with cellulose fibre / PVC laminated gypsum tiles with MPL film on rear side, 8 mm thk.for fixing in 600 mm x 600mm grid,Make: Gyproc/ La gyp 26 Door shutter repair : Taking down door shutter of any description exc. 1 sqm and not exc. 2 sqmand repairing and adjusting to the required size including fixing builders hard ware and refixing to the same opening. complete all as specified and directed. 27 Dismantlingof structural steel work including doors, gates, but excluding framed truss etc. Complete all as specified directed. 28 UPVC window / Ventelator : Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension . Complete all as specified and directed. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, 29 UPVC window : Three track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardwares and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. 30 UPVC door : Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proofS.S. wire mesh (Two nos. glazed & one no. wire meshpanels) made of (big series) frame 116 x 45 mm & sash46 x 82 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead/ double glazingbead of appropriate dimension. (Area of door above2.00 sqm upto 5.00 sqm) comprising of uPVCchambered frame, with in-built roller track and sashextruded profiles duly reinforced with 1.60 + 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionuPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extremepanels along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zincalloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be120 kg), G.I fastener 100 x 8 mm size for fixing frameto finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut andfusion welded at all corners, including drilling ofholes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof siliconsealent over backer rod of required size and ofapproved quality, complete all as specified anddirectd. 31 steel wire cloth : Supplying and Fixing in repairs stainless steel wire cloth0.36mm nominal dia.(Guage 28) of wire and width of aperture 1.4mm to wooden / steel doors/ windows, including fixing with and necessary screws, nut bolts,nails and removal of existing damaged cloth etc., complete all as specified and directed 32 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.0 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 33 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.8 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 34 Wooden Wall panelling : S & F of Prelaminated particle board18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work. Complete as specified and directed at site. 35 Wooden panelling frame work : S&F of battens frame work using wooden clean sawn 2nd class soft wood battens of cross sectional area exc. 15 & not exc. 25 sq.cm at a spacing of 35 centres. Complete as specified and directed at site. 36 PCC paving : PCC 1:4:8 in floors/ pavingoftype D-2, 1:4:8 with 40mm graded aggregate,100 mm thick.Complete all as specified and directed. 37 Earth work in excavation in all kind of soils by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge 38 Soling (or sub base) of spread thickness 150 mm with broken boulders or quarried stone, inter sticesfilled, surface formed and rolled and consolidated torequired gradient and camber. Complete all as specified and directed. 39 Hard core with broken stone/boulders of gauge not exc. 63mm, deposited, spread leveled in layers not exceeding 15 cm thick, and watered consolidated to required gradient & camber including watering. Complete all as specified and directed. 40 Moorum filling in floors or pavings laid in layers not exe. 15cm thick , spread leveled and rammed including watering. Complete all as specified and directed 41 Stone sett flooring (M&L) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 42 Edge stones to flooring (M&L) with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 43 PCC paving : PCC 1:2:4 in floors/ pavingoftype B-2, with 40mm graded aggregate, 100 mm thick. Including finishing concrete surface even and smooth surface without using extra cement.Complete all as specified and directed. 44 Wearproof topping 20 mm thick using CC 1:2:4, as specified incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner). Complete all as specified and directed. 45 Supply of metalic floor hardener 46 Surface excavation not exceeding 30 cm deepand averaging 20 cm deep in hard / dense soil and getting out. Complete all as specified and directed 47 PCC FLOORING : Cement concrete of 100 mm thickness in floors, sub-floors, sub-bases, pavings etc. oftype B-1, 1:2:4 (20 mm graded aggregate) 48 Smoth finish : Finishing cement concrete surface even and smooth using extra cement. 49 CC Paver blocks : S&F of Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement & pigment (Coloured)Complete all as specified and directed. 50 CC chequered tiles :S&F of cement concrete chequered tiles with grey pigment cement and pigments(Coloured tiles) for pavements. size of tile 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors.Complete all as specified and directed. 51 PCC paving : PCC 1:3:6 in floors/ pavingof type C-2, with 40mm graded aggregate, 100 mm thick.Complete all as specified and directed. 52 Forming 12mm thick Expansion joints for 100 thick slabsfilled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A. ’ Complete all as specified and directed. 53 Structural steel (S&F) : Structural steel work confirming to Fe-410 W (Gde-E-250) quality-A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, including application of one coat of Zinc chromate primer paint .Make:TATA, Jindal 54 Structural steel (S&F) : Structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Steel confirming to Fe410W (Gde E-250 quality A). Make : TATA, Jindal, Complete all as specified directed. 55 Structural steel (S&F) : Mild steel bolts. purpose made. of dia. of neck n.exc. 12 mm with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long. Complete all as specified directed. 56 Roofing sheet : Supply and fixing of pre painted galvalume aluminium zinc coating GI basedcorrugated/ trapezoidal profile roofing sheets of thickness 0.5 mm having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws etc. Make : TATA / Jindal /Essar. Complete all as specified and directed. 57 Supply only of liquid water proofing compound for incorporating concrete.Make. Fosrac, BASF, SIKA 58 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating. complete as specified and directed. 59 Kerb stone : Providing precast cement concrete using Type-B1, 1:2:4 20 mm graded aggregatein window or doorcills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets,etc. with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4. Complete with joints to match . Complete all as specified and directed. 60 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in roofkerbs or mud stops, rounded orchamfered on edges.complete as specified and directed. 61 PCC : Plain Cement Concrete (1:2:4) Type B2 using 40 mm graded aggregate in foundations, floors, filling and mass concrete, Complete all as specified and directed . 62 RCC : Reinforced cement concrete (Type B1, 1:2:4 with 20 mm aggregates) in columns, pillars, piers, posts etc. Complete all as specified and directed. 63 REINFORCEMENT : Mild steel(TMT) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. . 64 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 100 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 65 SWG PIPE : Supply & fixing of 100 mm dia Salt Glazed Stoneware drain pipes Grade A, including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 66 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 150 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 67 SWG PIPE : Supply & fixing of 150 mm dia Salt Glazed Stoneware drain pipeslaid in trenches including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 68 Earth work in excavation of all kind of soils by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Complete all as specified and directed . 69 Returning, filling in of excavated soils, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. 70 PVC PIPE : Supply and Fixing of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid or fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 71 PVC PIPE : Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 72 Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit iring, etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed. 73 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces. Complete all as specified and directed. 74 S & F ofG.I. Tubes of Size 40 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 75 S & F ofG.I. Tubes of Size 25 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 76 S & F ofG.I. Tubes of Size 1/2‘’(15 mm), medium grade including all fittings to walls and ceilings or in floors/trenches. 77 Supply & Fixing Rotational moulded polyethylene water storage tanks (PVC cylindrical vertical with closed top) hoisted and fixed in position 1000 lit capacity. make : Syntex 78 BALL VALVES : 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Complete all as specified and directed. 79 NAHANI TRAPS : Supply & Fixing ofCI Nahani traps 100mm with grating including jointing to went pipe with CC 1:2:4complete all as specified and directed at site. 80 GULLY TRAP : M&L for PVC/SWR gully traps, of size 125 mm x 110 mm all as directed and specified. 81 GRATING : Supply and fixing of grating doom 100 mm dia. of PTMT (min. weight 25 gms) 82 PVC D/E PIPE CONNECTION :Supply and fixing of PVC Double End Pipe connection.in repairs, size:15mm with end nuts & washers of length 600 mm. Make : Kohinoor. Complete all as specified and directed. 83 ALUMINIUMPARTITIONS : Supply and fixing complete of anodised aluminium powder coated frames for partition frames and windows etc. all complete as directed by E.I.C. 84 ALUMINIUM WINDOW SHUTTERS : Supply and fixing complete of anodised aluminiumwindow and ventilator shutters powder coated fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary jointig cleats, glazing clips, rubber neoprane packing, handles 2 nos. in each door, hinges, anodised aluminiumsnap beading, screws etc. complete all as directed by E.I.C. 85 HINGES : Supply and fixing of extruded Al. alloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-21 of size 125mmincluding all as specified and directed . 86 Antique aldrop : Supply and fixing of 200 mm long Antique model Brass mixed heavy alloy, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed.All as specified and directed and as approved by EIC. 87 Brass hinge: Supply and fixing of extruded brassalloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-11 of size 125mmincluding.All as specified and directed and as approved by EIC.. 88 Antique tower bolt : Supply and fixing of Antique model Brass mixed heavy alloy, barrel tower bolts of extruded section of size 200 mm and fixed all as directed.All as specified and directed and as approved by EIC. 89 Antique Door handle : Supply & fixing of Extruded Antique model Brass mixed heavy alloy, cast type polished bright handles 150 mm long, Complete all as specified and directed 90 TOWER BOLT : Supply and fixing of Aluminium anodised, barrel tower bolts of extruded section of size 200 mm and fixed all as directed. 91 BOW HANDLE: Supply & fixing of Extruded aluminium alloy handles 150 mm long, fabricated type, anodised. Complete all as specified and directed 92 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be easured separately), removing materials to store for keeping in safe custody for reuse at site and making good. 93 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 94 point wiring:S&F / Drawing of cables in PVC pipe,OneLight point or onefan point controlled by one switch with cables 1.5 sq.mm size of copper conductor cables FR PVC single core sheathed cable 95 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 5 amps independent, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 96 point wiring: S&F /Drawing of cables to One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 97 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 15 amps independent, with cables 4.0 sq.mm size of copper conductor cables FR PVC sheathed. 98 S & F of ceiling rose,3 phase/PVC/Polycorbonate, Isolate body 99 S & F ofswitch modular type of one module, 6 amps 100 S & F ofsocket, 2/3 pin combined, 6 amps, 2 Module 101 S & F ofswitch modular type of one module, 16 amps 102 S & F ofsocket, 2/3 pin combined, 16 amps, 2 Module 103 S & F ofFan step regulator 120 W, 2 Module 104 LED LUMINAIRE :Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/ Halonix 105 S & F of round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 106 S & F of LED tube lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 107 LED Street Light :Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/Halonix.complete all as specified and directed 108 Exhaust Fan: Supplyand Fix Exhaust Fan made of sturdy Engineering plastic complete with Lauvers, Shutteers, voltage 230 V,50 HZ, RPM 1200, Copper winding ofsweep 250mm.complete all as specified and directed. 109 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) 110 Industrial socket plug: Supply and fixing of 240 V, 20 amps, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB. 111 MCB :Supply and fixing of MCB / Isolator, 240 V, single pole 40 amp 112 MCB :Supply and fixing of MCB / Isolator, 240 V, double pole 40 amp 113 MCB D.B : S & F of Sheet Metal enclousers for D.B ofsingle doorof SPN,8 way with 200A rated bus bar,240V 114 MCCB: Suppply and fixing of MCCB 3 pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. 115 S & F of Modular metal flush box 6 module 116 S & F of Modular white cover plate with frame 3 module 117 S & F of Modular white cover plate with frame 4 module 118 S & F of Modular white cover plate with frame 6 module 119 S & F of Modular white cover plate with frame 8 module 120 EARTHING : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and directed 121 Earth continuity conductor : Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip. complete all as specified and directed 122 Dismantlng ofAsbestos cement (corrugated,semi corrugated, etc.) sheets in roofcoverings. Sheets shall be deposited to stores as directed. 123 Cutting or uprooting grass on old CC/brick tiles or on old mud phuska,and Taking down old Taf felt and loose material from the roof, cleaning the bitumen surface by wire brushing, washing down & disposing the pealed off tar felt muck etc. for complete as directed. removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. 124 Surface painting : Removal of old tarfelt sheets,Wire brushing and cleaning top surface of roof tops and surface painting, with a layer of bitumen primer for bitumen membrane @ 0.50 ltr/sqm by the same membrane manufacturere of density at 25° C, 0.87-0.89 Kg/ltr and viscosity 70-160 cps and then left the surface 4 to 8 hours for drying.Complete as specified and directed. 125 Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coatwith lndustrial bitumen 85/25 forwaterproofingtreatments at the rate of 1.2 kg / sqm . 126 Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced applicationby torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm.Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. 127 Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. 128 Rolling shutter : S&F ofSteel rolling shutters 1.25 mm thickness of lathe, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle. Complete all as specified and directed. 129 Rough excavation notexceeding1.5 m deepin drains etc in loose/soft soils andgetting out 130 Scarifying : Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc.400 sqm and the thickness Exc 50 mm and n.exc 100 mm deep 131 Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 132 Macadam : Premix bituminous, macadam with paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less).Complete all as specified and directed. 133 Pot holes : Repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth,making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadamusing paving bitumen, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings,6.3 mmsizeand again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm.Complete all as specified and directed. 134 Preparing Black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 135 Applying evenly a priming/tack coat with bituminous primer using paving bitumen at 5kg per 10 sq metre. Complete as specifiedand directed. 136 Bituminous premixed carpet, 2.5 cm consolidated thickness, with 0.34 cu.m. of stone chippings mixed with 18.25 kg of binder (paving bitumen)per 10 sq.m and mixed in mechanical hot mix plant and laid with mechanical paver and rolled using power roller 8-10 T capacity and compacted to required camber and gradient to uniform smooth surface. Complete as specifiedand directed. 137 Supply and fixing of Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing complete. 138 Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint and application of priming paint plaster coat. 139 Rendering synthetic enamel painting on new Steel surfacesof any description over 10 cm width or girth- TWO coats including one coat of red oxide Zinc chrome paint. Make: Asian paints/Berger 140 Complete removal existing treatment of of white washing onsurfaces of walls/ concrete. 141 Complete removal existing treatment of of white washing on surfaces of ceilings. 142 CHALK WHITENING : M&L - Chalk whitening (white cement-based, water-resistant, white wall putty) of plastered surfaces as preparatory to distempering on wall surfaces, Make : Birla wall care, complete all as specified & directed. 143 PRIMER : Priming plastered and other surfaces with alkali resistant priming paint. Make : Asion/Dulux- all as specified and directed . 144 WHITEWASH ON CEILINGS : M&L - White washing on ceilings- on old decorated surfaces- including preparation of surfaces – ONE coat of White Wash-complete all as directed. 145 WHITEWASH ON WALLS : M&L - White washing on Walls – on old decorated surfaces- including preparation of surfaces - TWO coats of White wash - complete all as directed. 146 PLASTIC EMULSION PAINT:Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint-complete all as directed. Make: Asian -Apcolite / Dulux-promise. 147 OBD : M&L - Rendering Oil Bound Distempering on old surfaces -including preparation of surfaces on walls - TWO Coats of OBD - complete all as directed. Make : Asian-tractor Uno / Berger-Butterfly / Indigo-gold. 148 External weather proof painting on walls : Material & Labour for applying Two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces. all as specified and directed, Brand : Asian apex,Berger weather shield, Nerolac Rain coat. 149 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting onOld painted Steel surfaces- surfaces of any description over 10 cm width or girth including preparation of surfaces-TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 150 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on Old painted Steel surfaces- surfaces of any description n.exc 10 cm width or girth including preparation of surfaces- TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 151 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on wooden surfaces - old surfaces of any description over 10 cm width or girth including preparation of surface - TWOCoats- all as specified and directed-Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 152 FRENCH POLISHING : French polishing on old surfaces of any description, width or girth –including cleaning and preparing the surface- One or more coats. all as specified and directed. Make : Sheenlac, sealer 153 Supply and fixing of Safety lever locks mild steel with 4 levers for rolling shutters as directed. 154 Fan Hook: Supply and Fixing of Fan hook with double anchor bolt complete fixing as per instructions of EIC. 155 IWC : IWC of approved make fixed with P trap Make: Hindware/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 156 CONCEALED FLUSHING SYSTEM : Wall mounted concealed flushing system (including frame, control plate and installation kit) with dual flush mode of capacity 10 ltrs. Make: Jaquar(Solo)/ Parryware(Prime)/ Cera(Fountain). Complete all as specified and directed. 157 MIRROR : Mirror 5 mm thk. with bevelled edge fixed with concealed screws Make: Saint Gobain/ Nilkamal/ Casa Gold. Complete all as specified and directed. 158 Switch board box with frame plate and cover plate , metal flush box18 module: Supply and Fixing of covering plates with Metal Flush box andcover plate frames of 18 module of make Legrand/ Schneider/ Havellscomplete all as specified by the EIC 159 Concertina coil & 6 straight RBT strands : Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina cross type fencing, GI steel plate & GI core wireon wall top using concertina coils stretched to approx.6 meters length at site and clipped with three nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc.). Including additional three horizontal R.B.T strands to be fixed with vertical portion of MS angle supports as directed in site. Complete all as specified and directed at site. 160 Accoustic sheets : supply and fixing of choice colourPolyester Fiber Acoustic Board / tiles, Thickness: 12mm, for insula-tion and accoustic purposes, 60x60 cm in size, fixed to wall / ceiling surfaces on snap grid orwith nails to timber frame work or with Z bar/clips etc as specified by manufacturer.Complete all as specified and directed. 161 Floor mat: supply and fixing of choice colourNylon carpet for floors minimum 6 mm thicknesshaving better accoustic co-efficient ,fixed to floor with approved adhesiveas specified by manufacturer.Complete all as specified and directed. 162 ACP wall lining : Supply and fixing of decorative choice colour solid finished Aluminum composit panel 4.0 mm thick sheeting on external wall surfaces upto 12.0 mter heights fixed over aluminium/MS framed wall surfaces as specified by manufacturer. Cost includes ACP panel, frame work, jointing glue and scafolding etc. Complete all as specified and directed. 163 UPVC window (Single glazed panel shutter & fixed wire mesh panel): Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series)frame 47 x 50 mm & sash 47 x 68 mm both havingwall thickness of 1.9 ± 0.2 mm and single glass paneglazing bead of appropriate dimension (Area ofwindow upto 0.75 sqm.) comprising of uPVC multi-chambered frame, sash and mullion (where everrequired) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel sectionmade from roll forming process of required length(shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casementhandles, G.I. fasteners 100 x 8 mm size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Including SS wire mesh panel with aluminium beeding fixed to outer face window using adjustable /removable clips. Profile offrame & sash shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be alsofusion welded including drilling of holes for fixinghardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finishedwall shall be filled with weather proof siliconsealant over backer rod of required size and ofapproved quality, complete all as specified anddirected by Engineer-in-Charge. 164 WALL TILES : Supply & fixing of Coloured digital glazed ceramic tiles in vertical surface 300x600 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell. 165 PVC door frame : S & F of solid WPVC Door Frame of size 100x60 mm heavy density of 11100 kg/cum and high quality PVC laminated of choice colour. Complete all specified and directed. 166 PVC door shutter : S & F of Factory Made Solid WPVCDoor Shutter with wood free EPS, 32 mm thick, heavy density 700 kg/cum and high quality PVC laminated on both side of choice colour. 167 Staircase railing : Supply and fixing of designed Stainless steel hand railing not less than 0.8 mtr height for stairs, balconies etc. using SS grade 304/316 members for balusters & rails etc. and covered with 12 mm thick tampered toughned glass. Design & model shall be as decided by EIC. Cost inclusive of glass, design and other mountings. Complete all as specified and directed. 168 Handicap grab bar : S&F of stainless steel anti slip vertical swing handicap bath room grab bar/rail with paper holder of min. 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 169 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 170 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 0.45 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 171 Wood Door : Supply and fixing of modern & designer soildTeakwood door shutters for Main Doors 32 mm finished thickness as decided by EIC . 172 EWC : Supply and fixing ofItalian Collection ceramic Floor Mount Western Commode, Rim less, One-piece for Bathrooms with Syphonic vortex Flushing system and soft closing seat cover including connection pipe.Make : Jaquar Fusion, Hindware Fabio, Cera cinova 173 WASH BASIN : Supply and fixing of Under counter Wash basin rectangle of approved make along with waste coupling, waste pipe and connection pipe, brackets etc. Make : Jaquar(Continental)/ Cera(campa)/ Parryware(Aqiline). Complete all as specified and directed. 174 URINAL : Supply and fixing ofSensor Urinal pan of approved make with auto flushing system including connection pipe, waste coupling and waste pipe Make: Jaquar(Aquisense)/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 175 PILLAR COCK : S&F ofsensorbased table top model Pillar cock with auto closing system of make: Jaquar / Hindware/ Cera. Complete all as specified and directed. 176 CONCEALED STOP COCK : S&F of CP Concealed stop cock of make : Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 177 2 WAY ANGLE COCK : S&F ofCP 2 way angle cock Make: Parryware(Uno)/ Cera(Fountain)/ Jaquar(Solo). Complete all as specified and directed. 178 EWC JET FAUCET : S&F of EWC jet faucet of make: Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 179 BIB COCK : S&F ofCP Bib cock of make: Jaquar(Solo)/Parrywaare(Uno)/ Cera(Fountain). Complete all as specified and directed. 180 SOAP DISH : S&F of SS soap dish of make Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 181 Hand drier: Supply and fixing of plastic Automatic Hot air drierfor bath rooms of approved make. Make :Orchid / Dolphy / Bajaj. Complete all as specified and directed. 182 Liquid soap dispensar: Supply and fixing of Liquid soap dispensar for bath rooms of approved make. Make :Jaquar / Orchid / Dolphy. Complete all as specified and directed. 183 Toilet paper holder: Supply and fixing of stainless steel single toilet paper roll holder of approved make. Make :Jaquar continental / Parryware sigma/ Cera Icon. Complete all as specified and directed. 184 Urinal partition : Supply and fixing of HPL (High-Pressure Laminate) urinal partitions using 12 mm thick compact board of width 400 to 500 mm and height 1200 mm of approved make and fixing with stainless steel brackts. Complete all as specified and directed. 185 Bldg.Expansion joint : Preparation of joint by grinding of groove surfae, remoal of dust, providing polymer mixed cement mortar on both sidea of groove and crack filling if any in floor level, fixing of baker rod 25x25 mm to control depth of groove, Providing and applying Nitoseal PU50 of Fosroc or equivalant having MAF 25% or above to the groove 25x12 mm. Including fixing / covering of joint with APP based polymetric membrane sheet sufficient width. Complete all as specified and directed at site. 186 Forming V grooves on granite surfacesn,exc 10mmdeep and n exc 10mm on face in steps, cooking platform, and other similar situations etc. 187 Hiring / Engage of JCB for cleaning, moving and loading materials like sand, gravel, or demolitionand removal of debris and other miscellaneous purposes as directd. The rate includes diesel and driver required to run the vehicle. 188 Carpet grass : Supplly and laying of carpet grass on levelled soil surface including preparing the soil bedby loosning the base ground 100 mm thick and removing old unwanted grass if any and necessary watering as directed. 189 Supply and laying of red earth / soil in loose state which is free from debris, grass and other vegitation to be used for gardening purposes as directed. 190 Architectural design : Before commencement of work Contractor should take architectural consultancy servies for entrance arch at the entrance gate, building front elevations and garden designs by authorised institutions / authorised Designer. Complete all as directed by EIC
Contract Date: May 16, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 4
2.
Heavy Industries and Public Enterprises #10706525 Price Bid
Tender For Selection Of An Event Management Agency ( Ema ) For Inauguration Of India International Convention Centre ( Iicc ) , Dwarka, New Delhi; 1 Havan At Foyer Area 2 Havan Kund, Havan Samagri And Pandit For Havan Rituals 3 Centre Thematic Setup Of Size 10M X 10M For Havan Rituals 4 Wooden Chairs 5 Cocktail Tables For Hi-Tea Arrangements 6 Buffet Counters With Frill For Hi-Tea Arrangement 7 Q Managers 8 Floral Decoration At Foyer Area ( High Quality Fresh Flowers ( Cosmos Flower, Gaillardia Flower, Zinnia Flower, Dahlias Flower, Peonies Flower, Fox Brush Orchids Flower, Tulips Flower, Gloriosa Lily Flower, Pineapple Lily Flower, Rain Lily Flower, Flower, Roses- Different Colour, Carnations Flower, Birds Of Paradise ) . Theme Of Floral Decoration To Be Presented In Technical Presentation. 9 2.6Mm Led Screens Of Size 16 X 12 For The Various Locations With Sound Facility 10 Riser Of Size 12 X 4 X 26 With Branding And Side Black Masking For Led 11 Sound System Of Havan Rituals For 200 Pax With Mics 12 Digital Photographers For Havan 13 Digital Videographers For Havan 14 Genset For Other Leds And Other Requirements, Including Distribution 50 Kva Along With Diesel 15 Hi-Tea Arrangements, Including Tea / Coffee, Snacks, Etc. From A Reputed 5-Star Hotel 16 Main Event Area / Auditorium 17 2.6Mm Led Wall Of Size 100 Ft X 35 Ft For Stage Backdrop 18 Led Riser: 100 X 4 X 6 Inches High With Ply On Top, Carpet , Setup In The Main Auditorium. 19 Scaffolding Structure For Led Support 100 X 24 20 Flower Decoration On Stage. 21 Thematic Wall Of Size 20 Ft X 35 X 2 Numbers On Both Side Of Led Wall, Including Necessary Scaffolding 22 Hiring Of Show Running Team And Technical Team- Show Running Of The Entire Unveiling And Launch Ceremony Including Technical Coordination And On-Stage Flow 23 Additional Lights For Foh - Moving Heads 32, Wash - 24, Rgb Led -24 24 Techrider For Culture Artist And Other Artists 25 Sofa Seat ( High-End ) Mix Of 1, 2-, 3- And 5-Seater Sofas 26 Mozo Barricading / Fencing 27 High Platform For Media, Console And Camera Etc. 28 Mozo Barricading In Front Of Stage In D Shape For Hon’Ble Pm 29 Lightening Of Lamp By Vip 30 Q Manager 31 Genset For Main Stage Led, Including Distribution 32 ( 250 Kva+125 Kva Genset 375 Kva With Dieselups For Main Stage Led 375Kva 33 F&B Area 34 Buffet Counters With Masking & Frill 5Rft 35 5 Round Tables With 8 Banquet Chairs With High-Quality Linen 36 Cocktail Tables 37 Flower Decoration In Both Food Courts 38 Glass Water Bottles - Minimum 200 Ml 39 Hi-Tea Arrangements, Including Tea / Coffee, Snacks, Etc. From A Reputed 5 Star Hotel 40 Media Lounge 41 Media Lounge To Be Constructed In Hangar With Air- Conditioning, Platform, New Carpet, Lighting, Electrical Outlets, The Lounges To Have Acoustic Walls, Ceiling, Pantry With Serving Facility And Storeroom 42 Power Back-Up Dg For Media Lounge With Diesel 300Kva 43 Vip Toilets For Media Lounge 44 Facility For Live Telecast Of The Inaugural, Valedictory And Sectoral 45 Sessions In The Media Lounges. 46 Workstation With Seating Arrangements, Electric Sockets 47 Sofa Seating ( 2+1+1-Seater ) 48 Centre Tables 49 Chair For Round Table Sitting 50 Round Tables 51 Pigeonhole Rack 52 Laptop / Mobile Charging Stations 53 Computers For Media Workstations With B / W , Color A4 Size Printers 54 Stationary For Media Lounge 55 Decoration 56 Florals In Different Area ( High Quality Fresh Flowers ( Cosmos Flower, Gaillardia Flower, Zinnia Flower, Dahlias Flower, Peonies Flower, Fox Brush Orchids Flower, Tulips Flower, Gloriosa Lily Flower, Pineapple Lily Flower, Rain Lily Flower, Flower, Roses- Different Colour, Carnations Flower, Birds Of Paradise ) . 57 Logo Theme Flags 58 Appropriate Landscaping With Plants Across The Event Venue, Ensuringoverall Ambience Decor. 59 Gallery Showcasing Neo Bharat Theme 60 Setting Up For A Special Thematic Showcase / Gallery Area For Vip Walkthrough, Depicting Journey Of Iicc And India Milestones. Displays To Include 3D Cutouts, Printed Panels, Av Screens, Plasma Screens, And Tech Engagements Arranged In Aesthetic Manner. Theme Should Be Revolving Around Neo Bharat. 61 Carpeting In Open Area / Foyer Area 62 Coir Carpeting ( New ) And Maintenance Of The Carpet To Be Done. Red Carpeting ( New ) In Pathways / Approach Routes Taken By Vvip , VipS Within Convention Centre And Outside The Venue, Inside Dmrc 15000 Sqft 63 Thematic Gate 64 Main Thematic Gate Of Length 60- 80 Ft And Height 30-40 Ft. The Gate Should Be Made Using Different Material Like Wood, Pop, Fibre, Raisins, Brandings, Flex, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Depicting The Theme Proposed. 65 Small Gates Depicting The Theme Of Length 20-30 Ft And Height 12-16 Ft. The Gate Should Be Made Using Different Material Like Wood, Pop, Fibre, Raisins, Brandings, Flex, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Depicting The Theme Proposed. 66 Emergency / Miscellaneous Services 67 Control Room For Fire, Disaster Management Etc. In Form Of A Hangar And General Lighting For Officers For Various Services. 68 Medical Hangar With Air- Conditioning, Platform, New Carpet, Lighting, Electrical Outlets, Acoustic Walls, Storeroom, And Toilet Facility. Provision For Partition For Patient Rooms ( 10 Nos. ) , Seating Arrangement ( 05 Tables, 20 Chairs ) For Medical, Support Staff And Reception Area. 69 Power Back-Up Dg For Control Room And Medical Hangar 50 Kva With Diesel 70 Event Branded Pagodas ( 3X3 Sqm ) For Various Purposes Consisting Of Two Tables And Four Chairs Including Platform, Carpet, Dustbin, And Electrical Points. 71 Branding 72 Buntings, Banners, Scrollers, Etc. Of Appropriate Sizes At Various Locations At The Venue, As Well As Throughout The Prominent Places Of New Delhi Using Appropriate Eco-Solvent Printing Materials, Hoardings, Key Locations Shall Be Updated By Ema 73 Digital Signages For The Different Areas 74 Flex Iron Mounted Of Different Sizes In The Venue, Outside Venue And Within Dmrc Route Using Appropriate Eco-Solvent Printing Materials 50 Nos 75 Logo Of Iicc Needs To Be Installed At Various Locations Inside The Venue Of Various Sizes, Using Different Material Like Wood, Pop, Fibre, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Etc Of Different Sizes. 8X4 , 12X08, 20X12. 76 General Lighting 77 For The Entire Event Venue On Light Poles, Each Light Pole Having Of 150 Watts Metal Halide / Led Light / Rgb Light Rates Will Be Inclusive Of Wiring From The Source To Consumption Point Through Underground Cabling. 78 Collaterals 79 Invitation Design & Cards Printing With Qr Code 80 Car Stickers 81 Shuttle Stickers 82 Badges 2 Sided Printed With Punch Hole On 2 Sides & Lanyards For Organizers, Delegates, Artisans. 83 Badges & Lanyards For Volunteers / Working Team 84 Golf Carts 85 6-Seater Golf Cart With Driver And Charging Facility. 86 Shuttle Buses Electric Or Cng , 20 Seater Or Above 87 Innova Crysta Cars 88 Parking Area & Management 89 Parking Area To Be Created For 2000 Cars In The Designated Zones Per Site Layout With Proper Markings, Signages, Control Booth, Tin Barricading, Lighting, And Manpower To Control The Traffic Movement. 90 Event Branded Gate ( 24 Ft. X 18 Ft. ) For Different Parking Areas 91 Pa System For Announcements In Parking Area 92 Manpower 93 Emcee Who Would Be Proficient In Hindi And English, Artist Management, Logistics And Etc. 94 Visitor Management Including Hostesses, Volunteers, Helpers, Stage Coordinators, Hospitality Managers, Etc. Provide Uniformed And Well-Dressed Ushers On The Days Of The Event. 95 Photography & Videography 96 Complete Photography Setup ( 3 Nos ) , Videography Setup ( 5 Nos ) Using High End Cameras With Hd Live Mixing Unit, 36 Out Audio Video Di Box 97 Live Streaming Of The Entire Event, Live Relay Across All The Areas With Provision For Live Feed. 98 Multi Camera Videography With Zip Crane 99 Digital Photographers 100 Digital Videographers 101 Security Arrangements 102 Supplying, Installation And Maintenance Of Door Frame Metal Detector Machines For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan, 103 Supplying, Installation And Maintenance Of Handheld Metal Detector Machines With Adequate Manpower For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 104 Supplying, Installation And Maintenance Of Walky-Talky For The Entire Team, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 105 Supplying, Installation And Maintenance Of Baggage, Thermal Scanners Scanning Machines With Adequate Manpower For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 106 Frisking Booth For Females With Curtains 107 Complete Coverage Of Venue With Moveable And Zoomable Cctv Cameras With Monitoring Setup. 108 Human Resource Deployment 109 Security Personnel With Uniform For 24X7 Surveillance Male & Female 110 Housekeeping Team 111 Sanitization And Pest Control Of The Complete Convention Centre & Foyer Area , 3 Times In A Day, 3 Days Before The Event 112 Toilets 113 Bio-Chemical Toilet ( Male & Female ) 114 Safe Room 115 Safe Room For Vvip Around The Stage At Inaugural Hall Which Would Include Sofas, Chairs, Teapoy Tables, Flower Decoration, Water Bottles, Platform, Carpeting. ( 100 Sqm ) 116 Installations 117 Installations ( 490 Sqft ) To Serve As A Photo Opportunity; Well- Integrated On The Theme Of The Event And To Be Erected At The Most Suited Location At The Event Venue, For Maximum Engagement, Locations Needs To Be Mentioned In The Presentation 118 Miscellaneous 119 Wheelchair 120 Stone Plaque 121 Sitting Arrangement For All The Halls ( Carnation, Laburnum, Meeting Rooms At 3Rd Floor Aster Hall, Petunia Hall, Tulip Hall, Zinnia Hall, Daffodil Hall, Vvip Lounge, Furniture Lobby Area Furniture, Auditorium Area Furniture, Green Room & Artist Room Furniture, Etc ) - 2000 Pax 122 Green Room 123 Mirror In The Room For Artists 124 Table 125 Chairs 126 Cloth Hangars 127 Social Media Publicity 128 1 Content Development As Required By The Authority 2. Creation Of Event Specific Pages / Handles On Social Media3. Developing Social Media Strategy In Accordance With The Approved Branding And Publicity Plan 129 Vc Av Requirement For HonBle Pm 130 Hardware ( H.323 / Sip ) Videoconferencing System Configuration. Make: Videoconferencing Equipment Like Cisco / Poly / Panasonic Or Equivalents 131 Dedicated Lease Line Of 100 Mbps With 100 Mbps Dedicated Backup With A Different Isp Provider 132 Suitable Interface Converters To Connect Camera With Videoconferencing Systems Through Hdmi Input Supporting 1080P60 / 1080P30 133 Multiple Professional Full Hd Video Cameras With Live Mixing Setup 134 Photographers 135 Live Mixing Setup 136 Console Setup, Including Tables, Chairs, Black Masking 137 Stone Plaque => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
3.
Communications and Information Technology  #10279729 Price Bid
Tender For Miscellaneous Civil Work For Maintenance Of H-5 At Ctx Compound Prayagraj.; (i) Concrete/ RCC (a) Rectification of structural / superficial / non-structural cracks. (b) Rectification of dampness / seepage in roof slab / junctions & sunken portion. (c) Rectification of cracks in beam, shade, column. (ii) Brick work/ Concrete Block Masonry (a) Rectification of cracks in panel wall / portion. (b) Cracks / settlement of dwarf walls. (c) Rectification of efflorescence/ leaching. (iii) Joinery (a) Replacement of warped joinery. (b) Cracks in panels, rails / styles etc. (iv) Builders Hardware (a) Repairs / Replacement of loosened / pre-mature failure of fittings. (b) Tightening / Replacement of sag in mosquito proofing. (v) Steel & Iron work (a) Rectification / Replacement of defective part of rolling shutter. (b) Redoing of defective portion in fabrication / welding including painting. (c) Steel windows, grills, gates etc. – defects to be rectified. (vi) Roof treatment (a) Rectification of leakage / seepage of roof slab including covering at junction till guarantee period. (vii) Plastering (a) Rectification of structural / superficial cracks if any. (b) Rectification of protruding / peeling off plaster if any. (c) Rectification of efflorescence (viii) Flooring (a) Rectification of sinking portion of plinth protection including saucer drain. (b) Settlement of foundation & floors, hollow sounding, cracks in tiles/stones. (ix) Plumbing / Sanitary fittings (a) Making good of leakage through soil / waste pipe joints. (b) Replacement of looking mirror if found wavy. (c) Rectification of leakage of overhead tanks. (d) Leakage / seepage of sunken floor, blockage of taps / pipes, nonfunctioning of cistern. (x) Finishes (a) Making good of defective / dissimilar patches of painting to match with remaining surfaces, peeling of paint. (xi) Internal Water Supply (a) Repairs / Replacement of defective taps / fittings. (b) Repair to leakage of GI/ SS water pipe lines including joints. (c) Removal of blockage of GI/ SS pipe lines. (xii) Roads (a) Repair of sinked portion of road & potholes, if any (xiii) Sewage (a) Rectification of slope / system if found defective during use. (b) Rectification of major blockage in Sewer lines. (c) Cracks & settlement of sewage lines. (xiv) Drains (a) Repair to Drains. (b) Settlement of Drains (xv) External Water Supply (a) Repairs to installations & fittings. (xvi) General (a) All manufacturing defects of structures / fixtures / fittings / equipment other than listed above including any defects of shrinkage or other faults that appear in the work within twelve months after a certificate of its completion is given by the Engineerin-Charge shall be rectified by the contractor. 1. Acrylic Emulsion Paint Asian (Royale), ICI (Velvet), Berger (Luxol Silk), Nerolac (Allscapes) 2. Premium Acrylic Smooth Exterior Paint Apex Ultima of Asian paints or equivalent. 3. Aluminium Composite Panel Alpolic, Aluco Bond, Reynobond, Euro bond, Al-strong, Aludecor. 4. Aluminium Extrusions Hindalco, Indalco, Jindal. 5. Aluminum Sections Hindalco, Indalco, Jindal. 6. Board & Plywood Duro, Greren, Century. 7. Ceramic/Rectified Tiles First quality tiles of :-Kajaria, Somany, Orient Bell, RAK. HR Johnsons 8. CP fittings Johnson, Jaquar, Marc, Cera. 9. CPVC Pipes Astral Flowguard, Ashirvad 10. Designer coloured cement concrete floor tiles for external used / Concrete paver blocks. Ultra, Nitco or Equivalent. 11. Epoxy Primer & Paints Berger, Pidilite, CICO. 12. Float Glass Modi Float, Saint Gobain, Tata. 13. Flush Doors (ISI Mark only) Green or Century or Equivalent 14. Galvanized/Stainless Steel Anchor Fasteners Arrow, Hilti, Fischer, Hatticth 15. Gun Metal Gate Valve Zoloto, Leader, SAINT 16. Gypsum Board False Ceiling Boral Gypsum, India Gypsum, USG, St. Gobain(Gyproc) 17. Hardner Hard crete of Snowcem India, MC Deritop F.H. 18. Hydraulic Door Closer Hardwyn, Godrej, Dorma. 19. Hydraulic Floor spring Hardwyn, Godrej, Dorma. 20. Laminate Greenlam, Decolam, Century, Formica. 21. Melamine Polish Melamine Gold of Asian Paint, Wudfin of pidilite, Timbertone of ICI Dulux. 22. M. S. Pipe Electro Steel, Apollo (ISI). 23. Marine Plywood / BWP Ply Century, Green, Duro 24. Oil Bound Distemper Asian (Tractor), ICI (Maxi lite), Berger(Bison), Nerolac (NAD) 25. Sanitary fittings Parryware, Hindware, Cera, Johnson, Somany 26. Plastic Connection Pipe Parryware, Kamal Delux. 27. Ply Wood Kitply, Green ply, Century 28. Pre-coated GI sheet for roofing Jindal Saw, Tata Blue Scope. 29. Polymer Modified Cementitious grout Bal-Endura, Pidilite, Ceco. 30. Pre-laminated Particle Board IS : 12823 (Gr-I, Type-II) Action TESA, Kitlam, Archid Ply, Asis, Green Lam 31. Primer Asian, ICI DuLux, Nerolac 32. PVC Rain Water Pipe & Fitting IS:13592 Type A Finolax, Supreme, Plasto. 33. PVC Shutter Rajshri, Sintex, Akal America. 34. PVC Tank (ISI Marked) Sintex, Star, Lotus, Plasto, Supreme. 35. R. C. C. Pipes (NP-2) ISI Make 36. Solid Plastic Seat Cover for EWC EWC standard seat cover white of Perryware/Hindware/ Neycer, Cera. 37. Stainless Steel Jindal Stainless Steel, Salem Steel 38. Stainless steel Sink with or without Draining board. Nirali, Hindware, Frankee, Cobra 39. Structural Silicon Sealant Dow Corning, Wacker, GE. 40. Structural steel section TATA, SAIL, RINL, Jindal. 41. Synthetic Enamel Paints ICI(Dulux),Asian (Apcolite),Berger (Luxol),Nerolac (NST) 42. Textured Exterior wall paint Snowcem, ICI dulux, Asian. 43. Towel Ring/Towel Rod/Towel Rack. Marc, Jaquar, 44. Tubular Section Windows M/S classic Engineers & Fabricator, Raipur, M/s JK Enterprises, Jaipur. 45. TMT Bars As per criteria laid down in Para 4.3 of Part-B 46. Vitrified Tiles First quality full body tiles of Orient Bell, Kajaria, RAK Ceramics, Johnson, NITCO, RESTILE. 47. Waste Pipe Kamal with brass checknut,Viking 48. Water Proofing Compound (Liquid) Pidiproof Ltd., Sico, Impermo 49. Wire mesh Sterling, Trimurty welded mesh. 50. White Cement JK, Birla. 51. Wall Putty JK, BIRLA 52. Work Stations/ Modular Furniture Godrej, Wipro 53. Stoneware pipe and Gully Trap Perfect or equivalent 54. PVC flushing System Parryware, Johnson, Commander 55. Tactile Tiles Johnson or equivalent 56. Plastic Emulsion Paint Asian, ICI, Berger, Nerolac
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
4.
Defence #9749554 AOC
Tender For Provision Of Klp For Sig Coy At Lalgarh Jattan Mil Station.; 2 Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately) 3 Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) 4 Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) 5 Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) 6 Lump sum price worked out by the tenderer for AREA DRAINAGE AND FOUNTAIN WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) 7 Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) 8 Lump sum price worked out by the tenderer for SECURITY WALL, FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) 9 Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) 10 Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION AND LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) 11 Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES, AIR CONDITIONING AND HOT WATER SUPPLY as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) 12 Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) 13 Lump sum price worked out by the tenderer for DEMOLITION AND DISMANTLING as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately) 14 Schedule A Part-XIII(FURNITURE) 15 Almirah small steel as per drawing No. FD-1032 sheet No. 1/1 16 Almirah large steel as per drawing No. FD-1031 sheet No. 1/1 17 Locker (built-in) (steel) as per drawing No. FD-1029 sheet Nos 1/2 & 2/2 18 Work bench workshop (1800 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1024 sheet No. 1/1 19 Book case (steel) as per drawing No. FD-1028 sheet No. 1/1 20 Bath Mat (PVC) as per drawing No. FD/E6/MAP/07 sheet No. 1/1 21 Barber Chair with adjustable Headrest as per Model No. IK-2687 of Ikonic Furniture/ Professional or equivalent of Marc Salon Furniture 22 Chair easy per drawing No. FD-229 sheet No. 1/1 23 Chair easy as per drawing No. FD-358 sheet No. 1/1 24 Chair writing as per drawing No. FD-280 sheet No. 1/1 25 Chair wooden bottom without arms as per drawing No. FD-285 sheet No. 1/1 26 Chair dining as per drawing No. FD-279 sheet No. 1/1 27 Revolving Chair of Make:- Geeken, Model No:- GB-401 or equivalent of Methodex, Godrej as approved by the GE 28 Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1 29 Desk with Dias Wooden as per drawing No. FD-399 sheet Nos 1/2 and 2/2 30 Board Notice/Display Board of size (900 mm X 1200 mm) of Make:- Alkosign, Model No:- ASGPB 90120 or other equilent make as approved by the GE 31 Drugget of variety No. Wollen, 60 tex X 12 warp, size 3000 mm X 2000 mm as per IS 697: 2005 32 Form with back (1800 mm long) as per drawing No. FD-78(M) sheet No. 1/1 33 Form without back(1525 mm long) (steel) as per FD-1027 sheet No. 1/1 34 Hat stand with mirror (large) as per drawing No. FD-362 sheet No. 1/1 35 Hot case small as per drawing No. FD-363 sheet No. 1/1 36 Ladder aluminium as per drawing No. FD-1025 sheet No. 1/1 37 Mirror (1200 mm X 1200 mm) 38 Pointer short 900 mm as per drawing No. FD-1041 sheet No. 1/1 39 Pointer medium 1220 mm as per drawing No. FD-1041 sheet No. 1/1 40 Pointer long 1525 mm as per drawing No. FD-1041 sheet No. 1/1 41 Receptacle as per drawing No. FD/E6/MAP/13 sheet No. 1/1 42 Side rack with tray three spaces (steel) as per FD-1023 Sheet No. 1/1 43 Sofa set single seater as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 44 Sofa set 5 seaters (3 + 1 + 1) as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2 45 Stool steel (510 mm high) as per drawing No. FD-409 sheet No. 1/1 46 Stool 305 mm X 305 mm X 760 mm (steel) as per drawing No. FD-81(M) sheet No. 1/1 47 Meat safe as per drawing No. FD-47(M) sheet No. 1/1 48 Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/1 49 Table officers (steel) as per drawing No. FD-1003 sheet Nos 1/2 & 2/2 50 Table marble top (1530 mm X 900 mm X 760 mm) as per drawing No. FD-298 sheet No. 1/1 51 Table dining 6 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1 52 Table with drawer (900 mm X 600 mm X 760 mm) (steel) as per drawing No. FD-1008 sheet Nos 1/2 & 2/2 53 Table for Havs & Ors (steel) as drawing No. FD-1007 sheet No. 1/1 54 Table (600 mm X 600 mm X 760 mm) as per drawing No. FD-293 sheet No. 1/1 55 Table centre two tier (900 mm X 450 mm X 400 mm) as per drawing No. FD-274 sheet No. 1/1 56 Table centre as per drawing No. FD-375 sheet No. 1/1 57 Teapoy as per drawing No. FD-278 sheet No. 1/1 58 Schedule A Part-XIV(ARBORICULTURE) 59 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Ashoka Regional of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 60 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Azadirachta indica ( Neem ) plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 61 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Jamun of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 62 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Peepal plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 63 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Shesham plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 64 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Mahogany plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 65 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Gulmoharplant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 66 M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Keenu of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. 67 M & L for preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete all as specified and as directed. Note: Cost of sludge, manure or extra earth to be paid for separately. 68 M& L for plantation of shrubs, hedge etc. at the site including watering and removal of unserviceable material including shrub/ hedge plants of any type and of height 60-75 cm in earthen pots of size 20 cm complete all as specified and as directed. 69 M & L for trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure) complete all as specified and as directed. 70 Supplying and stacking at site dump manure screened through sieve of IS. designation 20 mm from approved source, including carriage from outside MD land complete all as specified and as directed. Note: Manure measured in stacks will be reduced by 8% for payment. 71 M & L for rough dressing the trenched ground including breaking clods complete all as specified and as directed. 72 M & L for uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation complete all as specified and as directed. 73 M & L for fine dressing of the ground complete all as specified and as directed. 74 M & L for spreading of sludge, dump manure and/or good earth in required thickness complete all as specified and as directed. Note: Cost of sludge, dump manure and/ or good earth to be paid separately. 75 M & L for grassing with selection No. 1 grass in rows 5 cm apart in both directions including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth complete all as specified and as directed. Note: The earth shall be paid for separately. 76 Schedule A Part-XV(MISCELLANEOUS PARTS) 77 S & F in integrated type Heat Pump water heater with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 3 HP, hermetically sealed with environment friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 12 kW and rated power input of not more than 2.5 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre. NOTE: (a) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (b) Heat pump should have a user friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump. 78 Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 1.5 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class O Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 year for compressor, 5 year for condenser and PCB card after Installation and commissioning of complete unit. 79 Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner cooling type both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 2 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class O Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8 for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 years for compressor, 5 years for condenser and PCB card after Installation and commissioning of complete unit. 80 Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed. 81 Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. 82 Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 4 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. 83 Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 20000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately. 84 Supplying, fixing, testing and commissioning Industrial cooler (evaporative cooling unit), minimum dia 900 mm, minimum airflow 15000 cum per hour, Axial fan type, Noise maximum 70 decibel, coverage area 100 to 200 sqm, water consumption 65 to 90 liter, UV protected cooler body including 36-liter water tank, standard duct with auto swing grills with all fixing arrangements complete all as specified and as directed. Note: - Industrial sockets and three phase control copper wires shall be measured and paid separately. 85 Supply, assembly and erection of stainless steel (SS-304 grade) of 0.8mm thick rectangular duct (for industrial cooler) jointed by TIG/MIG welding or riveted with SS flanges with neoprene gasket at joint, supports of MS angle iron or SS rods complete all as specified and as directed. Note: The design of the duct for industrial cooler shall be submitted by the contractor for the approval of the GE. 86 Disconnecting all existing connection including earth wire with transformer of capacity 200 kVA upto and including 315 kVA installed on plinth or 2 poles or 4 poles structures and taking down and shifting transformer from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation installed on plinth or 2 poles or 4 poles structures at new location including connecting all connections, earthing, conductors, cables, nuts, bolts, washers etc. complete all as specified and as directed. 87 Construction of platform for transformer having dimension (2000 mm X 2000 mm), height 2000 mm and foundation depth of 1200 mm including necessary earthworks in any type of soil, 150 mm moorum filling in foundation, 150 mm PCC foundation with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, brick work with sub class B bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick externally in two coats of (15 mm and 5 mm) in cement mortar 1:4, enclosed spaces filled with moorum, 75 mm PCC subbase of flooring with M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, 150 mm PCC flooring with M10(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash complete all as specified and as directed. 88 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 630 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 630 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 400 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 320 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCB, TPN, 10 kA, C-type, rated current 32 A: -1 No (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -4 Nos 89 Srl Item No 15.012 Continued......(E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 4 Nos (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 90 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 320 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCB, TPN, 10 kA, C-type, rated current 32 A: -2 Nos (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -6 Nos 91 Srl Item No 15.013 Continued......(E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 92 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 160 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (b) MCB, TPN, 10 kA, C-type, rated current 32 A: -1 No (c) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -9 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No 93 Srl Item No 15.014 Continued......(c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 94 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 160 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 35 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCB, TPN, 10 kA, C-type, rated current 32 A: -4 Nos (c) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No 95 Srl Item No 15.015 Continued......(c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 96 Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction,conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCB, TPN, 10 kA, C-type, rated current 32 A: -2 Nos (b) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -7 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 3 Nos (d) Danger Notice Plate for LT 97 Srl Item No 15.016 Continued......(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm. 98 M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed. 99 M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 10 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 100 Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. 101 Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 110 mm, minimum inside dia 82 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. 102 Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high J type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge. 103 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 104 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 100 and nominal outside dia 110 mm as per IS 4984: 2016 including all fittings and fixtures in trenches complete all as specified and as directed. 105 Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 100 and nominal outside dia 90 mm as per IS 4984: 2016 including all fittings and fixtures in trenches complete all as specified and as directed. 106 S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. 107 S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 200, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. 108 S & F factory made rubber coated cement concrete paver block 60 mm thick (M35 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. 109 Material and labour for construction and laying of kerb of size as directed directly on the road construction site with automatic kerb casting machine (kerb/divider making/laying machine), using M25 (Design Mix) grade cement concrete laid in position to the required line, level and curvature kerb stone cast continuous and making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) at a distance as directed, including making drainage opening wherever required, including necessary excavation/earth work and making good disturbed surface complete all as specified and as directed. 110 Material & Labour for providing and fixing stainless steel (grade X 02Cr19Ni1O, 304 S2, surface finish No. 4 as per IS 6911: 2017) gate made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. 111 Supply and fix punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations complete all as specified and as directed. 112 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 113 M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 114 M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 115 M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 116 M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 117 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 118 S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole upto 160 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately. 119 S & F blanking plate in DBs of MCB complete all as specified and as directed. 120 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 121 Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 122 Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 123 S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. 124 S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. 125 Supply, fixing and testing LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 126 Supplying, installing, testing and commission of commercial kitchen stainless steel exhaust, chimney/ hood system having the following components: - (a) Commercial kitchen stainless steel hood (6 feet long/ 2.8 feet wide) of stainless steel 304 grade, double filter absorber type, rust free grade steel, inbuilt with automatic sensor as per OEM specifications. (b) Automatic mode changer (drift air), turbo force 5 HP motor with bird screen for protection against bird and foreign materials, rust free body and plates, automatic shutter function complete metal body (c) Double coated high grade ducting material 40 feet long, high quality material as per OEM specifications Note: The contractor shall design the ducting portion as per the drawings and room capacity of kitchen portion of the drawings and calculate the requirement of ducting and submit the design to the GE for approval. The quoted rate shall be inclusive of all these aspects. 127 S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 128 S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed. 129 S & F 15 mm wash basin mixture, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromium plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specified and directed by engineer in charge. Make : Jaquar Cat No: 5001B or equivalent as approved by the GE. 130 S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed. 131 Supply, installation, testing & Commissioning of Mechanical type incinerator electrically operated, made of galvanised iron of capacity 50 Kg/hour suitable for burning including shredder complete all as specified and as directed. 132 S & F factory made rubber coated cement concrete paver block 80 mm thick (M40 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. 133 S & F glass mosaic tiles , thickness 4 to 5 mm on floor and on vertical surfaces with Type 3 adhesive as per IS 15477: 2019, in a bed of an adhesive average thickness not less than 6 mm and not exceeding average 12 mm in final bed thickness complete all as specified and as directed. 134 Supplying, installing, testing and commissioning outdoor type compact substation (CSS), factory assembled (non walk type) having 11 kV, 630 Amps, internal arc fault for 20KA for 1 sec as per IEC 61330/62271-200 and comprising as under: - (A) MV COMPARTMENT: 11 KV, 630A, 25KA/3 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271 - 202.IAC category IAC-AFL. The Switchgear includes the following HV cubicles The indoor non -extensible SF6 insulated RMU fully motorised consist of 1No. Vaccum Circuit Breaker with Riser (ICOG type) with self-powered relay for protection of transformer (a) Rated voltage should be - 12 kV (b) Rated power frequenecy voltage - 28 kV (c) Rated lightening withstand voltage - 75 kV (d) Rated current for Ring main feeder - 630 amps (e) Rated current for LBS feeder - 630 amps (f) Rated short time current - 25 kA / 3 sec (g) Rated short time making current -50 kA (h) Ambient temperature (0 deg C to + 50 deg C) (i) Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFLR (j) RMU shall be provided with protection CTs rated for 30 / 1amps, class - 10P10 accuracy , 2.5 VA burdan for circuit breaker (k) The feeder shall be self-powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol. (l) Dead short Circuit life of VI - 40 No 135 Srl Item No 15.053 Continued......(B) TRANSFORMER COMPARTMENT: Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 250 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. (C) LV COMPARTMENT: The LV compartment with Degree of protection-IP54 designed for a 50-degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment : - (a) 1000 Amps, 50kA withstand fault level capacity rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection (b) Air Circuit Breaker (ACB) of rated current 630 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection (Incomer) (c) Outgoing – (i) 320A, 4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics=25kA - 1 No, (ii) 160A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics-=25kA - 1 No, (iii) MCB TPN, 32 Amp, 10 kA- 01 (iv) MCB SPN, 10 kA, 6 to 32 Amos – 4 Nos 136 Srl Item No 15.053 Continued......(d) APFC Panel: Designing, manufacturing, supplying, fixing, erecting, testing and commissioning LT APFC panel with capacitor bank, conforming to IS 16636: 2017, 100 kVAR, outdoor installations, rated system voltage of the panel 440 V ± 10%, rated frequency 50 Hz, 3 phase, 4 wire, delta connected, rated impulse withstand voltage 8 kV, free standing, pedestal mounted, made of cold rolled close annealed sheet of minimum 2 mm thick for the load bearing structure and minimum 1.6 mm thick for door and partition, 50⁰C ambient temperature, IP 54 Ingress Protection, 500 Amp rated copper busbar, metallized polypropylene (MPP) dielectric type, resin filled box type, self-healing type, shunt capacitor as per IS 13340: 2012, switching configuration: 50 kVAR X 1 No + 25 kVAR X 1 No + 10 kVAR X 2 Nos + 5 kVAR X 1 No (total five steps), suitable protection in line with IEC and IS for overheating, over current, earth fault, over voltage, short circuit, thermal overload and over pressure, suitable size power and control cable as per Indian Standards, powder coated in grey colour, including microprocessor based automatic power factor correction controller with human machine interface, cooling fans, capacitor duty contactors, 7% detuned reactors, two earth terminals in the panel and as per the details mentioned below complete all as specified and as directed. and shall be including the followings: - (I) INCOMING: (i) MCCB rated current(In): 250A, ultimate short circuit breaking capacity (Icu): 50 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply – 1 No (ii) Microprocessor based automatic power factor correction controller (minimum 5 steps)- 1 No (iii) Cooling Fans to be provided for forced cooling (II) OUTGOING: (a) (i) 5 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No 137 Srl Item No 15.053 Continued......(ii) MCCB rated current(In): 15A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 5 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 5 kVAR 7% detuned reactor copper wound – 1 No (b) (i) 10 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 20 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 10 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 10 kVAR 7% detuned reactor copper wound – 2 Nos (c) (i) 25 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 50 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 25 kVAR capacitor duty contactors – 1 No 138 Srl Item No 15.053 Continued......(iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 25 kVAR 7% detuned reactor copper wound – 1 No (d) (i) 50 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 100 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 50 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 No (vi) 50 kVAR 7% detuned reactor copper wound – 1 No Note: (a) The kVAR rating of capacitor mentioned is for rated voltage of 440 V. However, the capacitor shall be provided for rated voltage of 480 V by enhancing the kVAR rating suitably. 139 Srl Item No 15.053 Continued......Outdoor Enclosure:- The enclosure shall be made of 2.0 mm thickness Galvanized Sheet Steel tropicalized to meet Indian weather conditions including all the partition sheets & doors. The base of the enclosure shall be of 4.0 mm thickness Hot Dip Galvanized Sheet Steel to ensure rigidity for easy transport & installation. The entire Package Substation shall be Factory Assemble & Factory Fitted. The enclosure shall have IP54 degree of protection for HT & LT switchgear compartment IP34 degree of protection for Transformer compartment. The Enclosure to be tested for Internal Arc fault test to the tune of at least 20 kA for 1 second adhering to as per latest IEC 62271-202.The temperature rise test on enclosure for K10 class. The enclosure exterior shall be powder courted. Only OEM make of CSS is acceptable. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. The enclosure, RMU and LV Breaker should be of same make for better co-ordination and Note:- Platform to be made as OEM recommendation is including in this quoted rate. (D) ACCESSORIES: (a) Multifunctional meter digital type of adequate capacity showing voltage, current, frequency, power factor, Kilo watt, Kilo watt hour with inbuilt selector switch with current transformer coils for three phase: - 1 No (b) LED indicating lamps (c) Danger Notice Plates for HT & LT 140 S & F telephone socket outlet including metal box complete all as specified and as directed. 141 S & F 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. 142 S & F television antenna socket outlet including metal box complete all as specified and as directed. 143 S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed. 144 M & L for construction of new valve pit/chamber of size 900 mm (Length) X 900 mm (Breadth) X 900 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class B bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. 145 M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 146 Supplying, laying, installing, testing and commissioning cable laying protection U shape tray of size 100 mm height and 300 mm width, made out of hot dip galvanised iron sheet of 2 mm thick including fixing accessories like cross over, bolt in partition, snap in position, supporting corner, horizontal bend, low elbow, rising elbow, T-piece, tray cover, edge protection, full threaded rod, slotted U channel, round head square neck bolt, flange nut, hinged joiner, screws, fastener, hook, nut, bolt, washer etc. complete all as specified and as directed. 147 Supply, installing, commissioning and testing of washing machine with washer extractor of capacity 60 kg (dry weight per washing cycle) front loading electrically driven including water connection from PVC tank to washing machine as per requirement and drain out pipe from machine to drain complete all as specified and as directed and comprising of following specifications/ accessories/capacity/size and material shall be as per OEM/Manufacturer recommendations: - (i) Industrial washer extractor. (ii)Outer drum/ Inner basket/ outer basket made out of high grade stainless steel sheet of SS304 grade with perforation. (iii) Front loading and unloading open pocket. (iv) Forward and reverse basket rotation. (v) 01 No Heavy duty high spin single phase motor, variable frequency drive type of suitable capacity and 01 Nos driver motor three phase 415 volts variable frequency drive type of suitable capacity. (vi) Suspension with shock absorber and springs. (vii) Fully programmable microprocessor and auto balance while extraction. (viii) Manual dosage of powder detergent. (ix) Door limits electric inter locking and emergency stop for safety and trouble free and operation both manual and auto lock. (x) Aluminium casted pulley and belt. (xi)Main body of full stainless steel 304 grade. (xii)Heater of suitable KW. (xiii) PCC foundation as required shall be as per manufacturers recommendation NOTE: - (a) Contractor shall submit necessary company test certificate and purchase voucher and warranty cards as per recommendation by vender. (b) Testing and commissioning shall be carried out by authorized rep of the firm/company for which no extra payment shall be made. 148 Supply, installing, commissioning and testing of drying tumbler electrically heated suitable for washing machine as per above item having loading capacity of 60 kg per charge Fin type Electric Heater of 48 Kw made out of SS pipe, front loading type, Auto Timed, Auto reveres, Microprocessor controlled with electric motor and electric panel complete. Fully die pressed door, inner basket stainless steel basket of min 503 litre volume, outer body mild steel sheet insulated with glass wool complete all as specified and directed. Note: - (a) The Contractor shall submit necessary company test certificate and purchase voucher and warranty cards as per recommended by vender. (b) Testing and commissioning shall be carried out by authorized rep of the firm/ company for which no extra payment shall be made. 149 S & F stainless steel (SS-304 grade) air grills for air swing and wider coverage complete all as specified and as directed.
Contract Date: Mar 05, 2026 Contract Value : 14.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
5.
Housing Urban and Rular Development #9456642 Technical Bid
Tender For Cultural And Urban Rejuvenation, Widening Beautifications Of Ramghat, Approach And Precinct At Chitrakoot (U.P.), 1 Cultural and Urban Rejuvenation, Widening Beautifications of Ramghat, Approach and Precinct at Chitrakoot (U.P.) 2 STAMB - 04 Nos. 3 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 6 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 7 Centering and shuttering including strutting, propping etc. and removal of form for 8 Foundations, footings, bases of columns, etc. for mass concrete 9 Columns, Pillars, Piers, Abutments, Posts and Struts 10 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 11 Supplying, fabricating, transporting, hoisting and fixing in position good quality of sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 12 Providing and fixing readymade Decorative Ornamental Stone CHATRI per customized size andDesign as per architect in charge Design as per architect in charge 13 Providing and fixing readymade Decorative Ornamental Stone Sclupture per customized size andDesign as per architect in charge Design as per architect in charge 14 GHAT EDGE FAÇADE BEAUTIFICATION 15 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 16 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 17 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.I. Sheet 18 Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. 19 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 20 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:Channels, angles, tees and flats 21 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 22 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 23 Centering and shuttering including strutting, propping etc. and removal of form for 24 Lintels, beams, plinth beams, girders, bressumers and cantilevers 25 Suspended floors, roofs, landings, balconies and accessplatform 26 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 27 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 28 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground within 50 metres lead. 29 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. 30 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: 13.24.1 in one coat 31 Melamine polishing on wood work (one or more coat). 32 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 33 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately).Second class teak wood35 mm thick shutters 34 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes4 mm thick glass pane (weight not less than 10 kg/sqm). 35 Providing and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with : 14.27.1 Second class teak wood 36 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :15.13.1 Of area 3 sq. metres and below 37 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm 38 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 39 (a) 250 mm x 10mm 40 (a) 200 mm x 10mm 41 Providing and fixing bright finished brass handles with screws etc. complete:125 mm 42 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 43 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)40mm WhiteSandstone: 44 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required (DSR 8.15) 45 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.(DSR 8.16) 46 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 meter height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose (2) The payment will be made once only for execution of all items for such works. 47 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm 48 Providing and Finishing wall with Smooth textured Stucco Marble/Sea shell/mettalics crinkle paint high sheen and smooth finish(oyster grey) shade to be aproved by Architect in charge (asian or equivalent) 49 Providing and Finishing surface with Artistic Mural and Painting as per Design received from Architect incharge 50 Providing and fixing of Cast-Iron bracket inspired by traditional architecture pattern as per designincluding fixing in wall etc all complete in direction of engineer in charge. 51 Providing & fixing of signages made in sand stone / marble stone with ingraving & inlay work as per drawign & design etc all complete in direction of engineetr in charge. 52 Providing and Fixing Awning with Polyester PVC Roll Up Awning, Shape Rectangle Material: Polyester, Frame Material: Aluminium, Pattern: Plain of approved make from Architect incharge including the cost of all the necessary fixtures and fittings 53 Stone Work Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 54 Providing and fixing ornamnetal stone chattri, the cost of ornamental engraving ethcing and hand carving through CNC or any suitable mediums, also incuding the cost of all necessary fixtures and fittings of Steel and Stone at all heights as per drawing approved from Architect incharge 55 Supplying, fabricating, & fixing in position ornamenrtal top shikhar and chattri of required size and proportion ingood quality sandstone of minimum thickness of 75mm inlcuding oranmentiaon through CNC, hand chisleing or any other medium required in cement concrete of size apprx.1000mm X .900MM & 200mm dimensions as per design approved by Architect in charge 56 Researh, design and execution of multiple forms of artworks on wall using CNC machines on upto 150mm thick sand stone as per approval with dry cladding using stainless Steel 304 Grade Fasterners & Cramps anchored to existing RCC/Brick wall surface as per site requirements all complete. Design will be depicted wtih the help of carving, embossing, engraving an inserting. The depth of the thickness of the letters/images/pattern on teh stone should range from 20mm thickness to 70mm from the base stone. At least 50% of the surface area of stone cladding will have decorative artwork, 50% area will have plain stone cladding of same material. The item includes stone finish all complete as per the approval of the Architect/Engineer-in-Charge. 57 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand), including ointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 7.29.1 Red sand stone 58 Providing and fixing red sand stone brackets 55x22.5x45 cm sunk and moulded including providing and fixing with 4 Nos gun metal cramp 25x6 mm 30 cm long 59 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 7.33.1 Red sand stone 60 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 61 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 62 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required. 63 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 64 Providing and injecting HM-500 Epoxy Anchoring Type: HM-500 : Red or Black Density: 1.5±0.1g/cm³ in proportion Mix Ratio: 3:1 Color/ or recommended by the manufacturer into drills cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (make Hilti/HM or equivalent) 65 FAÇADE PAINTING 66 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 67 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 68 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 69 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 70 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. 71 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 72 Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: 13.24.1 in one coat 73 Melamine polishing on wood work (one or more coat). 74 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 75 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 meter height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose.(2) The payment will be made once only for execution of all items for such works. 76 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm 77 Providing and Finishing wall with Smooth textured Stucco Marble/Sea shell/mettalics crinkle paint high sheen and smooth finish(oyster grey) shade to be aproved by Architect in charge (asian or equivalent) 78 COBBLED PATHWAY 79 Dismantling floors to be stone flagged or tiled floor and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 meters (200 ft.) 80 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 81 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 82 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall bepaid for separately 83 ACI (HIGH PERFORMANCE STAMPED CONCRETE) Applying and finishing the top surface of concrete, in accordance with sprinkling of ACI color hardener at the rate of 0.31 kg./sq.ft., Floating the surface with different types of floaters, application of release agent at the rate of 0.011 kg./sq.ft , stamping the concrete with stamping tools, cleaning the surface with water and application of acrylic based sealer at the rate of 0.035 ltr/sq.ft, for finishing. Complete for play area, parking areas, Compound flooring, Podium, Basement flooring, External roads etc. 84 RED SAND STONE PATHWAY 85 Dismantling floors to be stone flagged or tiled floor and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 meters (200 ft.) 86 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 87 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 88 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 89 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 Red sand stone 90 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 91 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cementmortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :Both face dressed 92 GHAT STEPS 93 Dismantling floors to be stone flagged or tiled floor and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 meters (200 ft.) 94 Dismantling sundried brick work including stackingofdismantling materialsas directed bythe Engineering- in- chargewith ina distance of60 meters (200 ft.) 95 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 96 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 97 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 98 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 99 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 100 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 101 Centering and shuttering including strutting, propping etc. and removal of form for 102 Foundations, footings, bases of columns, etc. for massconcrete. 103 Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc. 104 Suspended floors, roofs, landings, balconies and accessplatform 105 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 106 300 mm dia piles 107 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 108 Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 109 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.White/pink sand stone flooring 110 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 111 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 112 CHATRI PLATEFORM- 06 Nos. 113 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.Hard rock (blasting prohibited) 114 Dismantling floors to be stone flagged or tiled floor and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 meters (200 ft.) 115 Dismantling sundried brick work including stackingofdismantling materialsas directed bythe Engineering- in- chargewith ina distance of60 meters (200 ft.) 116 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 117 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 118 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 119 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 120 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 121 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 122 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 123 Centering and shuttering including strutting, propping etc. and removal of form for 124 Foundations, footings, bases of columns, etc. for massconcrete. 125 Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc. 126 Suspended floors, roofs, landings, balconies and accessplatform 127 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 128 300 mm dia piles 129 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 130 Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. 131 Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. 132 Group of two or more piles upto 50 tonne Safe capacity 133 Initial test (Test Load 2.5 times the Safe capacity) 134 Routine test (Test Load 1.5 times the Safe capacity) 135 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 136 Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 137 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. 138 Red sand stone flooring 139 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)40mm WhiteSandstone: 140 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required (DSR 8.15) 141 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.(DSR 8.16) 142 Researh, design and execution of multiple forms of artworks on wall using CNC machines on upto 150mm thick sand stone as per approval with dry cladding using stainless Steel 304 Grade Fasterners & Cramps anchored to existing RCC/Brick wall surface as per site requirements all complete. Design will be depicted wtih the help of carving, embossing, engraving an inserting. The depth of the thickness of the letters/images/pattern on teh stone should range from 20mm thickness to 70mm from the base stone. At least 50% of the surface area of stone cladding will have decorative artwork, 50% area will have plain stone cladding of same material. The item includes stone finish all complete as per the approval of the Architect/Engineer-in-Charge. 143 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.Red sand stone 144 Cost of Electrical 145 WHITE / PINK SAND STONE PATHWAY 146 Dismantling floors to be stone flagged or tiled floor and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 meters (200 ft.) 147 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 148 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 149 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.White/ pink sand stone 150 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 151 RED SAND STONE PATHWAY 152 Dismantling floors to be stone flagged or tiled floor and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 meters (200 ft.) 153 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 154 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 155 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 Red sand stone 156 Development of Chattri 157 Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 Red cement : 2 stone dust) with an admixture of pigment matching the stone shade : 158 ( Red Sandstone) 159 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with Red cement mortar 1:2 (1 Red cement : 2 stone dust) with an admixture of pigment matching the stone shade : 160 ( Red Sandstone) 161 Stone work plain ashlar in arches in super structure upto floor V level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with Red cement mortar 1:2 (1 Red cement : 2 stone dust) with an admixture of pigment matching the stone shade. 162 Both face dressed ( Red Sandstone) 163 Stone work plain ashlar in domes , in super structure upto floor V level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with Red cement mortar 1:2 (1 Red cement : 2 stone dust) with an admixture of pigment matching the stone shade. 164 Both face dressed ( Red Sandstone) 165 Changing rooms 166 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 167 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 168 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 169 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 170 Centering and shuttering including strutting, propping etc. and removal of form for 171 Lintels, beams, plinth beams, girders, bressumers andcantilevers 172 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 173 Thermo-Mechanically Treated bars of grade Fe-500D or more. 174 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 175 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 176 Supply and installation of Portable cabin of size 12’x4’ x 8.5’.Changing room including (3 Main Door, 3 fan, 3 Led Light, vinyl Flooring, 3 clothe Hanger and 3 bulked light above the door.3 mirror) & Legs and Hooks for easy lifting & Shifting with technical specification as given, All finishes and design work will be complete in direction of architect In charge.Base Square- Pipe Of 75X 40 MM with 5 mm thickness. Along With Square Pipe Of 75MM X 40 MM& 50x50mm.(Welded With M.S Square pipe From Length To Length.), Top frame - Square Pipe Of 50MM X 50 MM (Welded With M.S Pipe From Width To Width).Side wall stiffener- 40MMx20MM specially formed Square PipeStiffener Top- Square Pipe of 40 X 20 Mm (Welded With M.S.Square Pipe)Side Post- 65MMx65MM specially formed M.S. Square Pipe.Roof Outside- Specially Plain M.S. SHEET 1MM thick, properly both side slopeFloor- Strong 18MM Everest Cement Board with PVC Flooring, 177 Insulation- All walls within the external wall & inner wall are filled with Glass wool 25 mm. thick which possess a rare combination like lower thermal conductivity & high resistance to moisture. 50MM on CeilingCeiling• Top outer MS sheet of 1mm thick.• Top inner decorated with 8mm thick MDF boardWall Surface• Exterior wall: - 1 mm MS Sheet.• Internal wall: - 8mm thick MDF board in Changing room & ACP in washroom.All wiring shell be concealed type and shell be PVC insulated copper wire. Single phase wiring with ISI mark. All electrical fitting in the Cabin Shall be 220-240V, Wiring, Modular switch and socket with wall Cabin Fan & 20 watts LED and Bulkhead(External) Light above door and 32amp MCB at the Input junction for safety.(ISI Mark) Anchor BrandAll components are primed externally and painted of best quality two coats of Enamel paint.Doors- Constructed of Steel Frame work by 30mm X 30mm X 3mm (thick) square pipe external wall made by M.S Sheet &Inner wall decorated by ACP Board and suitable door handles and hand drop. 178 Providing and fixing of Die cast Aluminum Pole duly primer coated & Polyester / Polyurethane painted including cost of Screen made of die cast aluminum framing, MS sheet & ornamental MS Perforated Sheet as per design and color approved by architect in charge 179 Male Urinal 180 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 181 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 182 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 183 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 184 Centering and shuttering including strutting, propping etc. and removal of form for 185 Lintels, beams, plinth beams, girders, bressumers andcantilevers 186 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 187 Thermo-Mechanically Treated bars of grade Fe-500D or more. 188 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 189 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 190 Supply and installation of Portable cabin of size 6’x4’ x 8.5’.Urinal Male including (2 Main Door, 2 Urinals, 2 exhaust fan, 2 Wash basin, Water Tank Stand, 2 Led Light, vinyl Flooring, 2 Soap case stand ,2 towel stand and 2 bulked light above the door.) & Legs and Hooks for easy lifting & Shifting with technical specification as given, All finishes and design work will be complete in direction of architect In charge.Base Square- Pipe Of 75X 40 MM with 5 mm thickness. Along With Square Pipe Of 75MM X 40 MM& 50x50mm.(Welded With M.S Square pipe From Length To Length.), Top frame - Square Pipe Of 50MM X 50 MM (Welded With M.S Pipe From Width To Width).Side wall stiffener- 40MMx20MM specially formed Square PipeStiffener Top- Square Pipe of 40 X 20 Mm (Welded With M.S.Square Pipe)Side Post- 65MMx65MM specially formed M.S. Square Pipe.Roof Outside- Specially Plain M.S. SHEET 1MM thick, properly both side slopeFloor- Strong 18MM Everest Cement Board with PVC Flooring, 191 Insulation- All walls within the external wall & inner wall are filled with Glass wool 25 mm. thick which possess a rare combination like lower thermal conductivity & high resistance to moisture. 50MM on CeilingCeiling• Top outer MS sheet of 1mm thick.• Top inner decorated with 8mm thick MDF boardWall Surface• Exterior wall: - 1 mm MS Sheet.• Internal wall: - 8mm thick MDF board in Changing room & ACP in washroom.All wiring shell be concealed type and shell be PVC insulated copper wire. Single phase wiring with ISI mark. All electrical fitting in the Cabin Shall be 220-240V, Wiring, Modular switch and socket with wall Cabin Fan & 20 watts LED and Bulkhead(External) Light above door and 32amp MCB at the Input junction for safety.(ISI Mark) Anchor BrandAll components are primed externally and painted of best quality two coats of Enamel paint.Doors- Constructed of Steel Frame work by 30mm X 30mm X 3mm (thick) square pipe external wall made by M.S Sheet &Inner wall decorated by ACP Board and suitable door handles and hand drop. 192 Providing and fixing of Die cast Aluminum Pole duly primer coated & Polyester / Polyurethane painted including cost of Screen made of die cast aluminum framing, MS sheet & ornamental MS Perforated Sheet as per design and color approved by architect in charge 193 Female Urinal 194 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 195 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 196 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 197 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 198 Centering and shuttering including strutting, propping etc. and removal of form for 199 Lintels, beams, plinth beams, girders, bressumers andcantilevers 200 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 201 Thermo-Mechanically Treated bars of grade Fe-500D or more. 202 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 203 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 204 Supply and installation of Portable cabin of size 6’x4’ x 8.5’.Urinal Female including (2 Main Door, 2 exhaust fan, 2 EWC with Seat cover, Flush tank, 2 in 1 Tapwith Jet Spray, 2 Wash basin, Water Tank Stand, 2 Led Light, vinyl Flooring,2 Soap case stand ,2 towel stand and 2 bulked light above the door).& Legs and Hooks for easy lifting & Shifting with technical specification as given, All finishes and design work will be complete in direction of architect In charge.Base Square- Pipe Of 75X 40 MM with 5 mm thickness. Along With Square Pipe Of 75MM X 40 MM& 50x50mm.(Welded With M.S Square pipe From Length To Length.), Top frame - Square Pipe Of 50MM X 50 MM (Welded With M.S Pipe From Width To Width).Side wall stiffener- 40MMx20MM specially formed Square PipeStiffener Top- Square Pipe of 40 X 20 Mm (Welded With M.S.Square Pipe)Side Post- 65MMx65MM specially formed M.S. Square Pipe.Roof Outside- Specially Plain M.S. SHEET 1MM thick, properly both side slopeFloor- Strong 18MM Everest Cement Board with PVC Flooring, 205 Insulation- All walls within the external wall & inner wall are filled with Glass wool 25 mm. thick which possess a rare combination like lower thermal conductivity & high resistance to moisture. 50MM on CeilingCeiling• Top outer MS sheet of 1mm thick.• Top inner decorated with 8mm thick MDF boardWall Surface• Exterior wall: - 1 mm MS Sheet.• Internal wall: - 8mm thick MDF board in Changing room & ACP in washroom.All wiring shell be concealed type and shell be PVC insulated copper wire. Single phase wiring with ISI mark. All electrical fitting in the Cabin Shall be 220-240V, Wiring, Modular switch and socket with wall Cabin Fan & 20 watts LED and Bulkhead(External) Light above door and 32amp MCB at the Input junction for safety.(ISI Mark) Anchor BrandAll components are primed externally and painted of best quality two coats of Enamel paint.Doors- Constructed of Steel Frame work by 30mm X 30mm X 3mm (thick) square pipe external wall made by M.S Sheet &Inner wall decorated by ACP Board and suitable door handles and hand drop. 206 Providing and fixing of Die cast Aluminum Pole duly primer coated & Polyester / Polyurethane painted including cost of Screen made of die cast aluminum framing, MS sheet & ornamental MS Perforated Sheet as per design and color approved by architect in charge 207 Covered drinking kiosk 208 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 209 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 210 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 211 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 212 Centering and shuttering including strutting, propping etc. and removal of form for 213 Lintels, beams, plinth beams, girders, bressumers andcantilevers 214 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 215 Thermo-Mechanically Treated bars of grade Fe-500D or more. 216 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 217 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 218 Providing and fixing of Die cast Aluminum Pole duly primer coated & Polyester / Polyurethane painted including cost of Screen made of die cast aluminum framing, MS sheet & ornamental MS Perforated Sheet as per design and color approved by architect in charge 219 Public Sanitation Block 220 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 221 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 222 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 223 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 224 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 225 With Chlorpyriphos E.C. 20% with 1% concentration 226 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 227 With Chlorpyriphos E.C. 20% with 1% concentration 228 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 229 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 230 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 231 Centering and shuttering including strutting, propping etc. and removal of form for 232 Foundations, footings, bases of columns, etc. for massconcrete. 233 Suspended floors, roofs, landings, balconies and accessplatform 234 Lintels, beams, plinth beams, girders, bressumers andcantilevers 235 Columns, Pillars, Piers, Abutments, Posts and Struts 236 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 237 300 mm dia piles 238 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 239 Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. 240 Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. 241 Group of two or more piles upto 50 tonne Safe capacity 242 Initial test (Test Load 2.5 times the Safe capacity) 243 Routine test (Test Load 1.5 times the Safe capacity) 244 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 245 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) 246 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 247 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 248 Cement mortar 1:6 (1 cement : 6 coarse sand) 249 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 250 Cement mortar 1:4 (1 cement :4 coarse sand) 251 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 252 Thermo-Mechanically Treated bars of grade Fe-500D or more. 253 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level 254 Thermo-Mechanically Treated bars of grade Fe-500D or more 255 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 256 15mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 2.25 F.M. (1) 1 cement : 6 coarse sand 257 Ground Floor 258 12mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 2.25 F.M. (1) 1 cement : 6 coarse sand 259 Ground Floor 260 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 261 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. 262 Ground Floor 263 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 264 Ground Floor 265 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade 266 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 267 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 268 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 269 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 270 Both side laminated 271 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM 272 gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) 273 Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre; each openable shutter upto 0.8m width) 274 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. 275 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.30 mm thick plain PVC door shutters 276 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer 277 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 278 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer 279 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 280 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 281 Providing and fixing ISI marked S.S. Sliding door bolts with nuts and screws etc. complete 282 (a) 300 mm x 16mm 283 Providing and fixing ISI marked S.S. Tower bolts black finish, (Barrel Type) with necessaryscrews etc. complete 284 300 mm x 10mm 285 250x10 mm 286 Providing and fixing ISI marked S.S. handles conforming to IS 4992 with necessary screws etc. complete.125mm 287 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) 288 admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by 289 Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120mm and minimum thickness at khurra as 65 mm. 290 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm). 291 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 292 P/F Mild steel or iron in heavey sizes such as trusses, built up gates, record racks, roof work, gates etc. wrougyht to required form, including drilling holes riverting or welding where necessary & their fixing, required for proper completion of the work 293 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 294 Two or more coats on new work 295 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing . 70mm thick 296 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 297 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 298 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 299 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 300 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone 301 Plumbing Work 302 SUB HEAD-I-SANITARY INSTALLATIONS 303 Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. 304 Providing & fixing toilet paper holder 305 C.P. brass 306 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 307 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 308 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 309 White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 310 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 311 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 312 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 313 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 314 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 315 15 mm nominal bore 316 Providing and fixing uplasticised PVC connection pipe with brass unions : 317 45 cm length 318 15 mm nominal bore 319 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 320 15mm nominal bore 321 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 322 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 323 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. 324 Granite Stone of approved shade 325 SUB HEAD-II-WATER SUPPLY 326 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 327 Concealed work, including cutting chases and making good the walls etc. 328 For Internal Toilet 329 15 mm nominal outer dia Pipes 330 20 mm nominal outer dia Pipes 331 25 mm nominal outer dia Pipes 332 32 mm nominal outer dia Pipes 333 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 334 Internal work - Exposed on wall 335 32 mm nominal bore 336 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 337 Terrace loop & Tank Filling Pipe 338 32 mm nominal bore 339 40 mm nominal bore 340 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 341 32mm diameter pipe 342 40mm diameter pipe 343 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 344 32mm diameter pipe 345 40mm diameter pipe 346 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 347 For vertical pipe connection with terrace ringmain 348 32mm nominal bore 349 40mm nominal bore 350 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 351 25 to 40 mm nominal bore 352 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 353 40 mm nominal bore, 206 mm long, weighing not less than 690 gms 354 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 355 SUB HEAD : III - ROOFING 356 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 357 110 mm dia (for rain water) 358 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 359 Single Push Fit Coupler 360 110 mm dia 361 Single tee with door 362 110x110x110 mm 363 Plain bend 87.5 deg 364 110 mm dia 365 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 366 110 mm dia 367 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 368 SUB HEAD : IV - INTERNAL DRAINAGE 369 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 370 Internal Toilet (Soil & Waste Pipe) 371 75 mm 372 110 mm 373 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 374 Bend without door (45°) 375 75mm 376 110mm 377 Bend without door (87.5°) 378 75mm bend 379 110mm 380 Y Fitting without door 381 75mm 382 110mm 383 Single Tee without door 384 75mm 385 110 mm 386 Single Tee with door 387 75mm 388 110 mm 389 Bend with door (87.5°) 390 75mm 391 110 mm 392 Clean Out Plug (COP) 393 75mm 394 110 mm 395 Reduced Y Fitting without door 396 110mm x 75mm 397 Coupler 398 75mm 399 110mm 400 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 401 For Wash basin & Urinal 402 32mm dia. Pipe 403 50mm dia. pipe 404 Elbow (45°) 405 32mm 406 50mm 407 Elbow (90°) 408 32mm 409 50mm 410 T fitting 411 32mm 412 50mm 413 Coupler 414 32mm 415 50mm 416 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 417 110mm x 75mm x 50mm/40mm (Toilet) 418 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 419 110mm x 75mm (Toilet & Kitchen) 420 Providing and fixing PTMT grating of approved quality and colour. 421 Rectangular type with openable circular lid 422 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 423 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 424 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 425 100 mm diameter 426 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia 427 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 428 Electrical Work 429 SUB-HEAD - I: INTERNAL WIRING 430 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C 431 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 432 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 433 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 434 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 435 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 436 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep 437 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 438 SUB-HEAD II - FANS & LIGHT FIXTURES: 439 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 440 Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. 441 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 442 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN 443 SUBHEAD- III: DISTRIBUTION BOARD 444 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way Double Door 445 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 446 Single pole 447 Double pole 448 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 449 SUB-HEAD -IV : L.T. CABLES 450 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. 451 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 452 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 2 x 4 sq.mm, 453 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 6 sq. mm (19mm) 454 External Electrification 455 SUBHEAD- I : M.V. PANELS 456 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.SFP (OUTDOOR TYPE) IP 65Incoming : One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. SetsMultifunction Meter each incomingOne (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.3 No. 32 Amp DPMCB. (10 KA)10 No. 16 Amp DPMCB. (10 KA)2 No. SPACE & SPAREPanel described as above 457 SUBHEAD: - II - EARTHING 458 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 459 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 460 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 461 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 462 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 463 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 464 SUB-HEAD -III : L.T. CABLES 465 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 466 Up to 35 sq.mm. 467 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required 468 Up to 35 sq.mm. 469 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required 470 Upto 35 sq. mm (clamped with 1mm thick saddle 471 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 472 4 x 10 sq.mm 473 3 x 6 sq.mm, 474 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 475 2 X 6 sq. mm (19mm) 476 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 477 100 mm dia 478 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 479 100mm dia 480 150 mm dia 481 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 482 SUBHEAD - IV :Miscellaneous 483 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 484 SUBHEAD - V: EXTERNAL LIGHTING 485 Supply of Static White/ RGB/ RGBWSurface/Wall mounted Narrow/ Medium/ Wide/ Elliptic beam Linear Wall Washer luminaires suitable for outdoor applications of Facade Lighting. Power consumption should be between 36W at steady state full intensity. Luminaire should be able to run on DC Voltage.The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP66or higher. Operating Temperature : -10°C to +50°C, Operating Humidity : 10% -90%,.LEDs of CREE / LUMILED / OSRAM / NICHIA/ reputed make shall be used for the light fittings. 486 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.1 output per phase and suitable for single phase supply 487 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required 32 mm dia 488 Informative and Cultural Mural Walls 489 Earth work in excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.5 m. & lead of 30 m. including filling, watering and ramming of excavated earth dressing of sides and ramming of bottoms filling of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth in 200 mm th. layers and getting out (removal of) the excavated surplus soil and disposal of surplus excavated soil as directed by engineer-in-charge up to a distance of 30 m from foundation trenches 490 Providing and laying Cement Concrete 1 :4 : 8 (1 Cement : 4 coarse sand : 8 graded stone agg.40 mm. nominal size) with cost of centring and shuttering in foundation and under floors including curing, supply of all materials, labour, T & P etc. required for proper completion of the work 491 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 492 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 493 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 494 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles 495 Brick work in super-structure in 1:4 (1 Cement :4 Coarse sand ) above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honey combed brick work for wall of one brick thick etc all complete in direction of engineer in charge. 496 Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wroughtto required shapeas necessary includingbendingforproper completion of theworkand includingsupplyof steelitswastage bend hooksand authorised overlapping shallbe measured upto floor two level. 497 12mm cement plaster in single coat on Rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 3 Coarse sand. 498 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - Exposed face machine cut and table rubbed with rough backing. 50 mm thick Red Sand Stone 499 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 500 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 501 Researh, design and execution of multiple forms of artworks on wall using CNC machines on upto 150mm thick sand stone as per approval with dry cladding using stainless Steel 304 Grade Fasterners & Cramps anchored to existing RCC/Brick wall surface as per site requirements all complete. Design will be depicted wtih the help of carving, embossing, engraving an inserting. The depth of the thickness of the letters/images/pattern on teh stone should range from 20mm thickness to 70mm from the base stone. At least 50% of the surface area of stone cladding will have decorative artwork, 50% area will have plain stone cladding of same material. The item includes stone finish all complete as per the approval of the Architect/Engineer-in-Charge. 502 Centering and shuttering including strutting, propping etc. and removal of form for 503 Foundations, footings, bases of columns, etc. for massconcrete. 504 Lintels, beams, plinth beams, girders, bressumers andcantilevers 505 Columns, Pillars, Piers, Abutments, Posts and Struts 506 Horticulture & Landscape Work 507 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 508 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 509 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 510 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 511 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 512 Rough dressing the trenched ground including breaking the clods. 513 Fine dressing the ground 514 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 515 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 516 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge With grass Turf 517 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 518 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 519 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 520 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 521 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 522 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 523 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 524 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 525 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 526 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 527 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 528 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 529 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 530 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 531 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 532 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 533 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 534 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 535 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 536 SHRUBS 537 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 538 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 539 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 540 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 541 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge. 542 Providing and stacking of Asparagus sprengeri of height 15 cm to 20 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 543 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 544 Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the officer-in-charge 545 TOURIST FACILITATION 546 Resting Areas for Tourist (Benches) {MR} 547 Providing & fixing ofred Sandstone/MS bench size 1500mm length and 450mm and height 600 mm including foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge. 548 Directional & Informative Signages (MR) 549 Providing and fixing StandAlone Signage in Marble/red sandstone of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size 550 Signage-A 551 Signage-B 552 Signage-C 553 EXTERNAL SEWERAGE & EXTERNAL WATER SUPPLY WORKS 554 COST OF SEWERAGE WORKS 555 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 556 Pipes, cables etc. exceeding 300 mm dia butnot exceeding 600 mm 557 1.50 m to 3.00 m depth 558 Pipes, cables etc. exceeding 300 mm dia butnot exceeding 600 mm 559 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) 560 Depth not exceeding 1.5 meter 561 Depth 1.5 to3.00meter 562 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. 563 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 564 150 mm.dia. RCCPipes 565 200 mm.dia. RCCPipes 566 250 mm.dia. RCCPipes 567 300 mm.dia. RCCPipes 568 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 569 150 mm.dia. RCCPipes 570 250 mm.dia. RCCPipes 571 300 mm.dia. RCCPipes 572 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 573 Extra for depth for manholes:Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 574 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). 575 With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 576 Extra for depth for manholes:Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 577 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 578 2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conformingto I.S. 12592, total weight of cover and frame to be notless than 182 kg. fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) including centering, shuttering all complete.(Excavation, foot rests and 12 mm thick cement plaster atthe external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 579 Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 580 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 581 COST OF EXTERNAL WATER SUPPLY WORKS 582 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 583 80mm nominal bore. 584 65mm nominal bore. 585 50mm nominal bore. 586 40mm nominal bore. 587 32mm nominal bore. 588 25mm nominal bore. 589 Supplying and fixing of specials for pressure pipe. 590 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 591 80mm nominal bore. 592 65mm nominal bore. 593 50mm nominal bore. 594 40mm nominal bore. 595 32mm nominal bore. 596 25mm nominal bore. 597 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 598 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 599 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : 600 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 601 DRAINAGE NETWORK 602 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 603 Drain 300 wide average.Depth 45 cm with R.C.C. slab 604 Drain 450 wide average.Depth 60 cm with R.C.C. slab 605 Drain 600 wide average.Depth 90 cm with R.C.C. slab 606 Transportation Charges of drilling equipment including assembly and other material as required. 607 Drilling of 675 mm. dia by rotary machine 608 Supply & laying of 350 mm. dia housing pipe (8 mm. thick) 609 Supply & laying of 200 mm. dia blind pipe (8 mm. thick) 610 Supply & laying of 200 mm. dia slotted pipe (8 mm. thick) 611 Supply & fixing of 350 mm. dia Socket 612 Supply & fixing of 200 mm. dia Socket 613 Supply & fixing of 200 mm. dia Bail plug 614 Supply & fixing of 350 mm. dia well cap 615 Supply & fixing of 350x200 mm. dia reducer. 616 Supply & fixing of 350 mm. dia housing clamp 617 Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I. 618 Development by air compressor including Transportation. 619 Development by O.P. Unit including Transportation. 620 Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition: 621 A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. 622 B - Total Head of pump set 45 m. 623 Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm. 624 Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set. 625 Supply of 80mm dia M.S. column pipe of class C both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements. 626 Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc. 627 Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make. 628 Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make. 629 Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour. 630 Supply of 80mm dia C.I. tee heavy quality i/c cost of material. 631 Supply of Guru/Fibing or equivalent make pressure gauge. 632 Erection & commissioning of pumping plants complete along with electric wiring. 633 Supply of steel wire rope of 1/2 size 634 S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing. 635 S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site. 636 S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 637 16 sqmm x 4 core 638 BOUGHT OUT ITEM 639 Urban Litter Bins(MR) 640 Providing & fixing of SS Dustbin with sandstone claddingsize 487 x 399 x 1138 fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge. 641 Specification of Y-Drinking Water(Receiving, storing, handling, shifting, installation, testing & commissioning ofWAE. AENON.45.CHA Pou Water Station C.A, RO Processing Capacity 25LPH, size: 466X580X1445, Watt; 220v/50Hz, Cooling 480w, Hot 450W, net weight 110kg, in material SS 304, with 3 tap: Cold 20 Ltr,Ambient-25Ltr including all accessories complete in all respect etc. (Make - Voltas or Equivalent)) 642 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above,anufactured in India,conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate ACPower with efficiency not less than 97%, total harmonic distortion less than 3% andsuitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories. 643 d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPEinsulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. asrequired. 644 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
6.
Drinking Water Supply and Sanitation #9338881 AOC
Tender For Setting Up Of Racks For Super Premium Shop At Gokulam Mall, Calicut , Billing Counter , Billing Table: Providing And Fixing Billing Counter Table- Box And Partition Is Made Of 16Mm Thick 710 Bwp Marine Plywood With 0.7Mm Off White Laminate And Shutters Are Made Of 16Mm Plywood Finished With 1 Mm 10510 Sd Laminate Finish. Providing All Necessary Hardware. Shutters And Box Edges Are Covered With Pvc Edge Band Using Automated Machinery. The Front Elevation Of The Table To Be Finished With Marble Finish Laminate As Per Design. The Price Is Inclusive Of 3D Embossed Logo In Brass. , Billing Backwall: Applying Texture Paint Of Approved Finish As Per The 3D (Leather Finish)The Cost Is Inclusive Of Material, Labour And Other Miscellaneous Works. The Above Rate Is Inclusive Of Brass Design Element(99Cmx104cm). , Billing Ceiling Element: Providing And Fixing Ceiling Element Using Gyproc Gypsum Ceiling Board With Necessary Sections And Perimeter. The Cost Is Inclusive Of The Cnc Cut Design Element As Per The Design. , Storage , Storage Racks: Providing And Fixing Storage Racks With Boxes And Partitions Made Of 16Mm 710 Bwp Marine Plywood, Finished With 1Mm Merino Laminate (14588 Rh - Apex Leaved Elm) And Pvc Edge Banding Applied Using Automated Machinery, Achieving A Total Thickness Of 34Mm. The Design Includes Painting Of The Back Wall And Top Branding Areas With An Approved Textured Leather Paint Finish And Brass Lettering As Per Design. The Cost Covers All Necessary Hardware For Assembly And Installation.15Mm Brass Tube Has To Be Installed In Every Rack As Bottle Fall Protection. , Island Storage Racks: Providing And Fixing Storage Racks With Boxes And Partitions Made Of 16Mm 710 Bwp Marine Plywood, Finished With 1Mm Merino Laminate (14588 Rh - Apex Leaved Elm) And Pvc Edge Banding Applied Using Automated Machinery, Achieving A Total Thickness Of 34Mm. The Design Includes Painting Of The Back Wall And Top Branding Areas With An Approved Textured Leather Paint Finish And Brass Lettering As Per Design. The Cost Covers All Necessary Hardware For Assembly And Installation.15Mm Brass Tube Has To Be Installed In Every Rack As Bottle Fall Protection. , Beer Storage Racks(Warm Beer Storage): Providing And Fixing Storage Racks With Boxes And Partitions Made Of 16Mm 710 Bwp Marine Plywood, Finished With 1Mm Merino Laminate (14588 Rh - Apex Leaved Elm) And Pvc Edge Banding Applied Using Automated Machinery, Achieving A Total Thickness Of 34Mm. The Design Includes Painting Of The Back Wall And Top Branding Areas With An Approved Textured Leather Paint Finish And Brass Lettering As Per Design. The Cost Covers All Necessary Hardware For Assembly And Installation.15Mm Brass Tube Has To Be Installed In Every Rack As Bottle Fall Protection. , Beer Chiller Storage Racks(Beer Chillers): Providing And Fixing Storage Racks With Box Made Of 16Mm 710 Bwp Marine Plywood, Finished With 1Mm Merino Laminate (14588 Rh - Apex Leaved Elm) And Pvc Edge Banding Applied Using Automated Machinery, Achieving A Total Thickness Of 34Mm. The Design Includes Top Branding Areas With An Approved Textured Leather Paint Finish And Brass Lettering As Per Design. The Cost Covers All Necessary Hardware For Assembly And Installation. 16Mm 710 Bwp Marine Plywood, Finished With 1Mm Merino Laminate (14588 Rh - Apex Leaved Elm) And Pvc Edge Banding Applied Using Automated Machinery, Achieving A Total Thickness Of 34Mm. The Design Includes Top Branding Areas With An Approved Textured Leather Paint Finish And Brass Lettering As Per Design. The Cost Covers All Necessary Hardware For Assembly And Installation. , Others , Painting: Includes Surface Preparation, Application Of Primer, Putty, And Multiple Coats Of Approved Paint Finishes For Walls, Ceilings, And Other Specified Interior Surfaces. The Scope Covers All Necessary Materials, Labor, Tools, And Equipment To Ensure A Smooth And Uniform Finish As Per The Approved Color Scheme And Design. All Work Will Comply With Relevant Quality Standards, Ensuring Durability And Aesthetics. Rates Are Measured Per Square Feet And Include Cleaning And Final Touch-Ups. , Electrical Works: Includes Supply, Installation, And Commissioning Of Wiring, Conduits, Switches, Sockets, Light Fixtures, Distribution Boards, And Earthing As Per Approved Layouts. All Work Complies With Standards And Safety Norms. Rates Include Materials, Labor, Necessary Chipping, Civil Works And Testing. The Price Is Excluding Generator. Quantity Of Work Has To Be Assessed By The Vendor As Per The Electrical Drawing. , Partition: Partition Works: Includes The Supply And Installation Of Partitions Using Gypsum Board As Per Approved Design And Specifications. The Framework Will Be Constructed Using Metal Or Wooden Sections, With Proper Cladding, Joints, And Finishes. Rates Include Materials, Labor, And Necessary Hardware, Measured In Square Feet (Sqft). , Cassette Ac: Includes The Supply, Installation, And Commissioning Of Cassette Air Conditioning Systems As Per The Approved Design And Specifications. Scope Includes Indoor And Outdoor Units, Refrigerant Piping, Ducts, Diffusers, Necessary Electrical Connections, And Insulation For Efficient Performance. Work Involves Testing, Balancing, And Commissioning To Ensure Proper Functioning. Rates Cover Materials, Labor, Tools, And Testing, Measured Per Unit Or Square Meter As Applicable, Adhering To Relevant Standards And Safety Regulations. , Tiling: Toilet Floor Tiles: Supplying And Fixing Kajaria Oslo Marfill Matt (1200X600) Floor Tiles For Toilet Floor 3Mm Spacered Joint Filled With Laticrete Epoxy Of Appropriate Colour In Cement Mortar 1:5, Including Cost And Conveyance Of All Materials And Labour Charges, Transportation Loading And Unloading Etc. Complete. Cost Is Inclusive Of Skirting
Contract Date: May 14, 2026 Contract Value : 37.30 Lakh
Government Departments No of Bidders 2
7.
Defence #9226750 AOC
Tender For Provision Of Otm Accommodation For Or Of Hq Mtn Bde At Laipuli Under Ge Dinjan; 1 Total amount of Sch A Part-IBuilding WorksNote :- This schedule is not pre-priced by MES and the rate indicated as Rs. 0.00 under column 6 signifies this fact only. 2 Soil investigation, Design, Fabrication and Construction of OTM ACCN FOR ORin RCC Framed Structure as per Arch Drg No. CWE/DIN/15/25 sheet No. 1/3 to 3/3 dated 20.01.2025 AND CWE/DIN/15/25 sheet No. 1/1 dated 20.01.2025 and specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE : Soil investigation will be measured and paid separately.(i) Size – As per Arch drawing(ii) Height – as per Drg(iii) Fdn – To be design as per SBC report with RCC framed construction.(iv) Plinth – Burnt Brick wk in CM 1:6(v) DPC – 40 mm thick PCC 1:2:4 with WPC(vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling.(vii) Seismic Zone – Strengthening measures for Zone V(viii) Roof – 0.50mm thick Pre-painted Galvalume sheet with MS steel frame structure, (ix) Ceiling : False ceiling with powder coated snap grid frame work. (ix) Internal Plaster – Internal 15 mm thick in CM (1:6)(x) Flooring – Coloured vitrified tiles in all room, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10.(xi) Dado/Skirting – Glazed ceramic tails over 10 mm thick cement screed in CM (1:3) up to lintel height.(xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & PVC doors in toilet bathroom(xiii) Joinery Window – Steel Window with Guard bars/grill (TD Drg No CESZ/2015/TD/19 Sheet No 1R/3, 2R/3 & 3R/3)(xiv) Steel Guard – MS Guard bars to window(xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)(xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core.(xvii) Painting – Synthetic enamel paint on steel/wooden surface.(xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer.External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment- As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi)18mm thick granite over CM 1:3 for steps(xxii) Sanatory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2& 2/2 andTD Drg No CESZ/TD-31 Sheet No 1/2& 2/2).(xxiii) Mosquito Proofing – All external Door and window. 3 NOTE: Schedule ‘A’ Part IItoIXare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured. 4 Total amount of Sch ‘A’ Part II (Excavation and Earthworks) 5 Total amount of Sch ‘A’ Part III (Internal Electrification) 6 Total amount of Sch ‘A’ Part IV (Internal Water supply) 7 Total amount of Sch ‘A’ Part V (Road/Path/Culvert) 8 Total amount of Sch ‘A’ Part VI (Area Drainage) 9 Total amount of Sch ‘A’ Part VII (External Water Supply) 10 Total amount of Sch ‘A’ Part VIII (External Electrification) 11 Total amount of Sch ‘A’ Part IX (Refrigeration and water cooler) 12 Total amount of Sch ‘A’ Part X (Hot Water Supply) 13 SCH A PART X(Miscellaneous B/R and E/M works)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 14 M & L for boring 100 mm dia hole in all kind of soil upto maximum depth 10 meter or up to refuse (N=100) whichever meet earlier including collection of undisturbed sample from cohesive soil only conducting standard penitration test at 12 meter and 1.5 meter interval alternatively as per relevant IS code complete all as directed. 15 Conducting necessary lab test on selected soil sample (obtained from item here in before) as per relevent nature moisture content, bulk and dry density sleve and hydrometer analysis, liquid and plastic limit, SP gravity unconfined compressive test (UU) or direct consolidation test etc complete all as relevant IS codes or all as specified and directed. 16 Completion of field work & lab test result and submission of report in Per Job quadruplicate suggesting depth of foundation type of fundation and safe bearing capacity with CD-1 (one) copy complete all as specified and directed. 17 S&F new PVC cable Junction Box IP66 halogen free and weather proof for out door installation sizenot less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole allas directed. 18 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20mm complete all as specified and directed. 19 Supply, install,testingand commissioning outdoor type LT outdoor panel of size 1.2m x 1.2m x 0.6m having IP 65 rating, factory made totally encloseddust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having magnetic locking arrangement in both front and rear door painted with powder coated paint and Aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system , including gland packing/bushes for entry/exit of cable from panel and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:-(Note : Foundation to be included in the quoted price)Incoming :-(a) MCCB, 4 Pole, 100-125A 415 V 36 kA - 01 no With thermal and magnetic releaseOutgoing :- (a)MCCB, 4 Pole, 63-100A 415 V 36 kA - 02 nos With thermal and magnetic release(b) MCB,TPN, 63A, 420 V, 18 kA- 03 Nos.(c) Phase indicator lamps (RYB) -set of 3(d) Aluminium bus bar 4 strip - 200 amps(Length should not be less than 0.8m) (e)Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc 20 M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as directed and specified. (Note: (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate.(ii) GI pipe has been measured and paid separately) 21 S&F RCC cable route indicator with embrossing mark as LT cable, of size75 cm x 15cm x 7.5cm complete all as specified and directed. 22 M&L for Cutting the existing 100mm dia DI pipe line and inserting Tee 100x100x50 mm dia with collars all as specified and as directed. 23 M&L for Masonry valve chamber of size 1000 x 1000 x 1000mm (internal dimensions) complete all as specified and as directed. 24 Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and as directed. 25 S&F LED batten (1.2M) inverter type made of polycarbonate housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. 26 S&F 10W,LED, Energy saving new generation bulk head with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications. luminaire with opal diffuser having lumen output of 1100 lumens at a minimum system efficiency of 110 lumen per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 27 Supply and fixing9W LED Retrofit lampsCode: 9W NEO LED LAMP B22 6500Kof make Surya orequivalent from list of makecomplete including taking down old unsv fittings. 28 M& L for cutting of circular hole at any type of wall for fixing of exhaust fan of 300 mm sweep, grouting 4 no 100 long 12mm dia stud bolt including making good to disturb surface of wall and painting as per existing colour complete all as specified and as directed.
Contract Date: Feb 04, 2026 Contract Value : 2.42 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
8.
Power #8649695 AOC
Tender For Construction Of Security Building For Barc (F), Rr Site Via Kota, Rajasthan.; 1 Part-I : Civil WorksSection- A: EarthworkEarth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refilling with selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of vegetation, grass, etc. complete andas directed by the Engineer-in-charge. 2 From 0.00 to 1.50 m depth from Average Ground Level 3 Earth work excavation by mechanical means (Hydraulic excavator) / manual means in foundation, in Soft Rockincluding shoring, dewatering if necessary, dressing the sides, ramming the bottom, refilling the sidesetc. with available selected excavated earth in layers of not exceeding 500 mm in depth, each layer well rammed and consolidated disposal of surplus excavated material within a lead of 200 m complete as per specifications and as directed by the Engineer-in-charge. 4 From 0.00 to 1.50 m depth from Average Ground Level 5 Earth work excavation in foundationin Hard Rockby Chiselling and / or by mechanical means (Hydraulic excavator)/ Manual means including dewatering if necessary, dressing the sides, ramming the bottom,and stacking and / or disposing within a distance of 200 m and filling the sides of foundation with available selected excavated earth in layers not exceeding 500 mm in depth, each layer well rammed and consolidated etc.complete all as per specifications and as directed by the Engineer-in-Charge. 6 From 0.00 to 1.50 m depth from Average Ground Level 7 From 1.50 to 3.00 m depthfrom Average Ground Level 8 Earth work excavation in foundation in Hard Rock by controlled Blasting (including explosive,drilling, muffling, pre shear line drilling )and by mechanical means (Hydraulic excavator) / Manual means including dewatering if necessary, dressing the sides of foundation, ramming the bottom of foundation, stacking and / or disposing within a distance of 200 m and filling the sides of foundation with available excavated earth in layers not exceeding 250 mm in depth, each layer well rammed and consolidated etc. complete all as per specifications and as directed by the Engineer-in-Charge. Blasting works to be executedas per safety norms and as per specifications and as directed by the Engineer-in-charge. 9 From 0.00 to 1.50 m depth from Average Ground Level 10 From 1.50 to 3.00 m depthfrom Average Ground Level 11 From 3.00 to 4.50 m depthfrom Average Ground Level 12 From 4.50 to 6.00 m depthfrom Average Ground Level 13 Supplying and stacking good excavated earth available at site , including compaction of earthwork in embankment under optimum moisture conditions to give at least 95% of the maximum dry density ( Proctor density). 14 Cutting and felling trees of girth beyond 30 cm up to and including 60 cm girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materials complete as per specifications and as directed by the Engineer-in-charge. 15 Lead charges for 1st 1 KM or part thereof, by mechanical transport including loading unloading, stacking / levelling etc. 16 Soil 17 Rock 18 Debris 19 Lead charges for Lead exceeding 1 KM but not exceeding 2 KM, by mechanical transport including loading, unloading, stacking / levelling etc. 20 Soil 21 Rock 22 Debris Note: The rates in respect of Item Nos. 7and 8 are applicable for NET Quantities arrived at after making deduction for voids @ 20% in respect of soil ,@ 50% in respect of Rock and @30% in respect of debrisfrom corresponding STACK / TRUCK Measurement 23 Supplying and injecting with approved quality chemical emulsion at the rates and concentrations as per IS 6313-2001 Part II for preconstructional antitermite treatment and creating a chemical barrier under and alround the masonry pits, masonry foundations, wall trenches, plinth filling, junctions of wall and floor, expansion joints, surfaces of RCC works for a depth of min. 500 mm from the finished ground level, surrounding of pipes, conduits etc., walls retaining soil above floor level, apron and drain along the perimeter of the building including all byeworks complete as per specification / IS 6313:2001 or latest revision and direction of Engineer-In-charge (only ground floor plinth area of the building will be measured for the payment in the following three stages. i) 20% after completion of the foundations ii) 50% after completion of the ground floor flooring iii) 30% after completion ofall treatment works including ground floor doors & windows. Work to be executed by approved agency and specified guarantee for 10 (ten) years shall be furnished by the contractor. 24 SECTION -B: Plain Cement Concrete & Reinforced Cement ConcreteProviding and laying in position cement concrete of 1:4:8 (1 cement, 4 crushed sand, 8 graded stone aggregate of maximum size 20 / 40 mm) with minimum cement content as per the latest revision of the relevant IS code including consolidation, finishing, curing etc. complete as per specifications and drawingsbut excluding the cost of Form work shuttering, centering complete at all levels. 25 Providing and laying in position cement concrete of 1:3:6 (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) with minimum cement content as per the latest revision of the relevant IS code including consolidation, finishing, curing etc. complete as per specificationsand drawings but excluding the cost of Form work shuttering, centering Complete at all levels. 26 Providing and laying in position cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of nominal size 20 mm) with minimum cement content as per the latest revision of the relevant IS code including consolidation, finishing, curing etc. complete as per specification and drawingsbut excluding the cost of Formworkshuttering, centering complete at all levels. 27 Providing and fixing at all levels, precast members using cement concrete 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of max. size 20 mm) in copings and / or bed blocks, plain window sills, shelves, louvers, steps, staircases, trench covers, drain covers etc. including hoisting and setting in position with C.M 1:3 (using crushed sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (using Crushed sand) on exposed surfaces complete as per specifications at all levels. 28 Providng and fixing at and near ground level precast cement concrete 1:2:4 in kerbs, edgings etc. as per approved patterns and setting in position with C.M 1:3 (using crushed sand) including consolidation, curing, cost of required centering, shuttering, finishing smooth with 6 mm thick cement plaster 1:3 (using crushed sand) on exposed surfaces complete as per specifications and as directed by the Engineer-in-charge. 29 Providing and laying in position Reinforced CementConcrete (RCC) of grade M-20 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching,mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.Note : The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. 30 Providing and laying in position Reinforced CementConcrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching,mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.Note : The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. 31 Providing and laying in position Reinforced CementConcrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching,mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications in superstructure up to 20.00m height.Note : The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. 32 EXTRA (over Item nos. 10,11,12,15,16 and 17) forReady Mixed Concrete ofall Grades of RCC / PCC manufactured in Fully Automatic Batching plantproduced inside Project areasas per direction of Engineer-in-chargecomplete as per specifications . 33 Providing and laying in position PLUM Concretewith 70 % cement concrete of 1:3:6 (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) and 30 % 150 to 230 mm size soling stones spreading uniformlyas per directions of the Engineer-in-Chargeincluding consolidation, finishing, curing etc. complete as per specifications and drawings but excluding the cost of Form work shuttering, centering complete at all levels 34 SECTION -C: Reinforcement Steel, Structural Steel & Formwork Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coatedG.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings.Steel supplied by the contractor. Using TMT bars of specified grades all dia bars. TMT bars to be supplied by the contractor shall conform to IS – 1786(Latest edition) and BARC specification . Note: 1) The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also testing third party from approved laboratories without any extra cost. 2) Binding wire required for the work will have to be supplied by the contractor at their own cost and will not be measured for payment. 3) Cover blocks shall be of same grade of concrete. 35 Providing Structural steel work in M.S Plain Plates and Chequrred Platesfor Embedded Parts, Trench Covers, Connection plates etc.including cutting, hoisting, fixing in position and applying a priming coat of approvedzinc chromate steel primer etc.including cost ofstructural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Usingmaterialsof approvedmanufacturers. All test reports to be provided along with the supply of the materials conforming to IS:2062. 36 Providing Structural steel work using angles, channels, joists and other sections, weldedand / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structuresincludingsupplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawingsand as directed by theEngineer in charge. 37 Up to and including 300 mm Joists, 350 mm channels, and below sections using materials ofapproved manufacturers.(ISI marked) All test reports to be provided along with the supply of the materialsconforming to IS:2062Notes for Item No. 21 & 22.01:1. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also third party testing from approved laboratories with out any extra cost. 2. Welding weights, connections, bolts and nuts shall notbe measured for payment but the cost of which shall be deemed to have been included in the rates. 3. Welding Electrodes from approved manufactrers meetinf all the technical specifications (the electrode gives smooth radiographic quality weld with low spatter and smoke) grade only shall be used. 4. Holes to be drilled only by Drilling machines and gas cutting of holes are not permitted. 5. Rate inclusive of all consumables like GAS, welding electrodes and tools and tackles etc. 38 Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members like pergolas, trusses, purlins, posts etc. using MS hollow / circular / square / rectangular tubular sections including applying a coat of Zinc chromate primer of approved make all as per specifications as per relevent codes and standards; all as per specifications, drwaings and as dircted by Engineer in Charge.Notes: 1. Yst 310 Conforming to IS 4923:1997 (Reaffirmed in 2009) with yield stregth of 310 N/sq. mm (For all rectangular Box sections Grade of steel to be used.) 2. Structural steel confirming to IS 2062 shall be supplied from approved manufacturers from their own plants rolled from virgin materials to be procured directly or from their authorised dealers and test certificate to be produced. 3. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also third party testing from approved laboratories with out any extra cost. 4. Welding weights, connections, bolts and nuts shall notbe measured for payment but the cost of which shall be deemed to have been included in the rates. 5. Welding Electrodes from approved manufactrers meetinf all the technical specifications (the electrode gives smooth radiographic quality weld with low spatter and smoke) grade only shall be used. 6.Holes to be drilled only by Drilling machines. Gas cutting of holes are not permitted . 7. Rate inclusive of all consumables like GAS, welding electrodes and tools and tackles etc. 39 Providing and fixing hand rail of approved sizeby welding etc. to steel ladder railing, balcony railing & staircases railing including applying a priming coat of zinc chromate steel primer etc. complete as per specifications using M.S tubes of ISI marked (Medium) of specified diameter and thickness. 40 Providing and fixing hand rail using304 grade Stainless Steel pipesof approved size and qualityby welding, mirror / matt polishing, fixing at siteetc. forbalcony railing & staircases railing including special sections as per drawings, specifications. complete as directed by the Engineer-in-charge. 41 Providing and fixing 304 grade Stainless Steel pipesof approved size, make and quality by cutting and placing in position including embedding if necessary complete as per specification and as directed by the Engineer in charge. 42 Providing and fixing in position 50 mm thick Thermocoleboard heavy density minimum 18.00 Kg/ CuM weight wrapped in 200 micron thickness Polythene sheets and placingin machine foundation workscomplete as per specifications and drawings andas directed by the Engineer incharge. 43 Providing and fixing at all levels MS bolts including nuts and washers of approved size, quality and makeas per requirements, drawingscomplete all as directed at site by the Engineer in charge 44 Providing and fixing at all levels SS bolts including nuts and washers of approved size, quality and make as per requirements and as per specifications, drawingscomplete all as directed at site by the Engineer in charge 45 Providing and fixingfabricated embedded parts/ platesmade 304 grade Stainless Steel pipes/ Plates/ Flanges etc.as perdrawings of approvedmake and qualityby welding,fixing, embedding in concreteat siteetc.as per drawings, specifications complete. Note :A sample to be fabricated and to be got approved by theProject Engineerbefore starting of work at site. This work to be executed through approved specialized agency. 46 Labour charges for Fixing in position in RCC / Masonry/ Form workMild steel or Stainless steel fabricatedEmbedded Parts supplied by the Department including transporting from the departmental stores, aligning, fixing in position, welding, providing necessary supporting arrangements etc. complete all as per drawings and specifications and as directed by the Project Engineer. 47 Weighing Up to 100 kg 48 Weighing Up to 100 kg and inclusive of 1000 Kg 49 Weighingabove 1000 KgNote : M.S. Steel / Reinforcement steel/ jigs & fixtures if required for supporting shall be paid under relevant item. 50 Providing , centering ,shuttering Form work using PVC film facedplywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels 51 For Sub Structure 52 For Super Structure 53 For Circular & curved shuttering In Sub Structure 54 For Circular & curved shuttering In Super structure 55 Providing and fixing double tubular scaffolding system using H- frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding. 56 SECTION -D: Masonry works & PlasteringProviding and constructing Half brick masonry using Flyash/ FlyashLime bricks in substructure with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 using crushed sand including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement. (Reinforcement will be paid under relevant item) 57 Providing and constructing Half brick masonry using Flyash/ FlyashLime brickswith minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 (using crushed sand) including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement in Super Structure at all levels. (Reinforcement will be paid under relevant item) 58 Providing and constructing Brickwork in cement mortar 1:6using crushed sand withFlyash / FlyashLime brickswith minimum 70 kg / Sq. cm strength of approved make and size in Sub structure including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. 59 Providing and constructing Brickwork in cement mortar1:6 using crushed sand withFlyash/ FlyashLime bricks with minimum 70 kg/ sq.cm strength of approved make and size in super structure at all levelsincluding, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. 60 Providing and constructing Random Rubble masonry using approved Rubble stone in foundation and plinth in C.M 1:6(using crushed sand) including raking out joints or simultaneous flush pointing below ground level / plinth level, curing etc. completeas per drawings and specifications. 61 Providing and constructing Random Rubble masonry using approved Rubble stone in super structure (above plinth) at all levels in C.M 1:6(using crushed sand) including raking out joints or simultaneous flush pointing above ground level / plinth leveland upto20m height including scaffolding, curing etc. complete as per drawings and specifications. 62 Labour charges for constructing Random Rubble masonry using Rubble Stone available at site in foundation and plinth in C.M 1:6(using crushed sand) including cost of bond stones, raking out joints or simultaneous flush pointing below ground level / plinth level, curing etc. completeas per drawings and specifications. 63 Labour charges for constructing Random Rubble masonry using Rubble Stones available at site in super structureupto 20m height at all levels in C.M 1:6(using crushed sand) including cost of bond stones, raking out joints or simultaneous flush pointing , curing etc. completeas per drawings and specifications. 64 Forming of grooves of uniform size from 12 mm X 12 mm to 25 mm X 15 mm in plastered surfaces as per approved pattern using wooden batterns, nailed to the under layer including removal of wooden batterns, repair to the edges of plaster panels and finishing the groove complete as per specifications and as per the direction of Engineer-in-charge 65 Providing 15mm thick plastering using Ready mix internal plastering compound of approved make for internalfaces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding completeall as per specifications and as directed at site by the Engineer-in-charge 66 Providing20 mm thick plastering using Ready mixexternal plastering compound ofapproved make for externalfaces of brickwork / concrete surfaces including preparation of the surface, curing, cleaningscaffoldingat all heights complete, all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge 67 Providing and fixingG.I. chicken mesh in the junctions of concrete & brick work / masonry or as directed by the Engineer in charge including cutting, fixing with nails in position before plasteringcomplete all as directed by the Engineer-in-charge. (Only area of the chicken mesh used alone will be measured) 68 SECTION -E: Flooringworks Providing and layingminimum 25 mm thickuniform shade Kotah stone flooring over 20 mm thick (Avearge) base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing in minimum three levels to obtainmirror polish complete with base cement mortar 1:4 (using crushed sand) all as per specifications, patterns and drawings complete. 69 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm ) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 70 Providing and LayingMinimum 25 mm thickuniform shade Kotah stonetreads and risers of steps, skirting,window sills in single length up to 2.00 metres length slabdado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finishcomplete as per specifications, drawings and as directed by the Engineer-in-charge 71 Extra (over Item No. 48) for nosing in steps of treads Using Kotah stone 72 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make, shade andcolour of size ranging from300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mmas approved byEngineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints withmatching colour Tile grout of approved make of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. 73 Providing and fixing 1st quality ceramic glazed floor tiles of minimum 300 - 600 mm long and300 - 600 mm wide andthickness not less than 6 mm conforming to IS 15622 of approved make in all colours and shades as approved byEngineer-in-charge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with white cement based Tile grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Enginner-in-charge 74 Providing and fixing Glazed VITRIFIED floor tiles of approved make of size above 600x 600mm and up to and including900 x 900mm conforming to IS 15622 inall colours and shades in Glossy or Matt or satin finishlaid over a bed of minimum20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints withwhite cement based Tile Grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge 75 Providing and Fixing3.00 mm thick Homogeneous PVC sheet / tile in flooring and skirting of approved make or approved equivalent meeting all the technical specifications as per relevant codes and standards in approvedpattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer meeting all the technical specifications as per relevant codes and standards including leveling small undulations with plaster of paris if required, rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-in-charge in approved colour and shade. 76 Supplying, stacking and laying of 230mm thickrubble soling stones as under floor baseincluding packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, murum etc. complete all as per specifications and as directed by the Engineer-in-charge. 77 Murum fillingunder floors of specifiedthickness in layers ofnot more than 150 mm thickness including supplying required materials andconsolidation etc. complete (Murum to be brought from outside campus ofRR Site). 78 Providing, supplying and laying pre polished granite slab flooring / dado / Wall claddingof approved blackshade, colour and texture withnot less than15-17mm thick graniteslabsover20 mmthick base cement mortar 1:4 (using crushed sand) laid and placedwith grey cement slurry includingfilling the joints with matching whitecement basedtile groutcomplete all as per specifications and drawings. 79 Providing, supplying and laying pre polished granite slab flooring / dado / Wall claddingof approved shade other than black, colour and texture withnot less than 15-17mm thick graniteslabsover20 mmthick base cement mortar 1:4 (using crushed sand) laid and placedwith grey cement slurry includingfilling the joints with matching whitecement basedtile groutcomplete all as per specifications and drawings. 80 Providing and fixing 1st qualitydigital highlighter300 x 450 mm- wall tiles meeting all the technical specifications as per relevant codes and standardsas and as approved byEngineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints withmatching colour Tile grout compound meeting all the technical specifications as per relevant codes and standards of matching shade complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. 81 Providing and fixing 1st qualityDigital highlighter 300 x 600mm- wall tiles meeting all the technical specifications as per relevant codes and standards and as approved byEngineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints withmatching colour Tile grout compound meeting all the technical specifications as per relevant codes and standards of matching shade complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. 82 Providing and fixing minimum 15-17 mm thick gang saw cut mirror polished (pre-moulded and pre-polished) machine cut Granitefor kitchen platforms, vanitiy counters, wash basin counters, door frames, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete at all levels. 83 Extra (over Item No. 60) for providing edge moulding to Minimum 15 mmthick Granite Slab counters, Vanitis etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. 84 Section- F:Doors, Windows, Glazing & False Ceiling works Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make or approved equivalent meeting all the technical specifications as per relevant codes and standards conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately)Notes: 1) The rates for aluminium is inclusive of all fastners required for fabrication and fixing in the walls. 2) All joints shall be of mittered Joints 3) A long M.S rod threaded at both ends to be provided in all aluminium door shutters in Top & bottom Horizontal members internally connecting Vertical members and fixed with M.S washers & nuts. 4) Only Aluminium members alone shall be measured and paid for. 5)Detailed fabrication drawings to be prepared and got approved by Project Engineer. 85 Anodised Aluminium sections (Minimum anodizing thickness of 15 micron) 86 Extra over above item for providing Colour Anodizing / Dyed anodizing Aluminium sections of approved colour with matching colour fittings. 87 Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item). 88 Withclear float glass panes of 6.00 mm thickness 89 Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc. with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-inCharge. 90 With tinted toughened floatglass panes of 6.00 mm thickness 91 With frostedglass panes of 6.00 mm thickness 92 Providing and fixingapproved quality stain less steel body roller wheelsfor slidingshutters 93 Providing and fixing approved quality and shape star locks cum handle for sliding shutters 94 Design, fabrication, supply and installation of frameless clear, toughened float glass of specified thickness for fixed glazing and openable panels (doors) with crystal edge polish and necessary patch fittingsfor swing doors, hunged on floor spring, , S.S.handles and locking arrangement and clear toughened float glass fixed for fins and all joints sealed with weather silicone sealent and fixed portion glass from top sides and bottom with anodised (minimumthickness 25 microns) Aluminium C channels (25 mm X 25 mm X 1.5mm thick)and all glass to glass joints sealed with clear thick weather silicone sealent and making the required grooves in plaster/concrete for fixing channels etc and making good the same with sealent/plaster of paris etc. complete all as per approved shop drawings, specifications and as directed by Engineer-in-charge. Note: Shop drawings to be prepared by the contractor as per the site conditions and the same shall be submitted for approval of Project Engineer before procurement. 95 Frameless fixed panels using 12mm thick clear toughened float glass including making cutouts, finishing the edges sealents etc complete. Glass area alone shall be measured and paid (necessary patch fittings shall be paid under relevant Item) 96 Frameless openable panels (swing doors) using 12mm thick for door leaves including making cut outs/ holes, finishing the edges with crystal edge polish ,sealents etc complete. Glass area alone shall be measured and paid (necessary patch fittings, locks & floor springs shall be paid under relevant Item) 97 Providing, supplying and fixingTop & bottom patch fittings with covers to suit floor springs & free pivots . 98 Providing, supplying fixing of Over panelpatch fittings withbacking plate and pivots 99 Providing, supplying fixingofhigh light to side light / corner link patch fittings with covers to suit floor springs & free pivots . 100 Providing, supplying fixingof connectinglink patch fittingsfor two or four glass 101 Providing, supplying fixingof Floor Spring with spindle insert closing force EN3, EN4,EN6with stainless steel satin finish cover plate complete including makingcut outs on floor & finishing the same complete. 102 Providing, supplying fixingofUniversal Centre lock with strike Plate 103 Providing, supplying fixingof corner lock with strike plate 104 Providing, supplying fixingofwall to glassconnectingpatch fittingsforfixed glass 105 Providing, supplying and fixing back to back Stainless steel Handle of 720 mm long 106 Providing and Fixing in position Suspended false ceiling system using 600 x 600mm Calcium Silicate Ceiling tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approved surface design and edge profileplaced in a suspended grid of size of 600 x 600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200 mm centers along the length of ceilingwith 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200 mm shall be inserted in to slots between the main tees at 600mm centersand thereafter in directionvertical to the longer tees, cross tees of size 24 x 28 x 0.33mm x 600mmshall be inserted to form a grid size of 600 x 600 mm resting on the periphery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness.The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge.The main teesto besuspended from the ceiling/ soffit with the help of metal dash fastners of 6mmx50mm, soffit clits of 25mmx35mmx1.60mm and 4mm dia G.I wire with galvanized spring steel leveling clips. the entire grid system shall be designed to bear a distributed load of minimum 15 kg/Sq.m (Only calcium silicate false ceiling area will be measured for the purpose of payment). 107 False Ceiling- tiles- Cosmos / Spintone / Hexa / Quadra Models with micro look system. 108 Providing and fixing in position suspended false ceiling system using 12 mm thick calcium silicate boards of100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KCplaced in a suspended grid of size of 600x 600mm made of hot-dipped G.I steel sectionswherein the ceiling sections of 0.55 mm thickshall be suspended at 1200 mm centres along the length of ceilingwith 4mm dia G.I wires/ 1 mm thick strip hangers made ofG.I sheet sections with necessary level adjusters andinter channelsof 0.90mm thick with connecting clips andresting on the perifery walls on wall angles of 0.55 mm thickness including providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings and as per directions of Engineer-in-charge.The main teesto besuspended from the ceiling/ soffit with the help of metal dash fastners of 6mmx50mm, soffit clits of 25mmx35mmx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips/G.I strip Hangers at 600mm centers . the entire grid system shall be designed to bear a distributed load of minimum 25 kg/Sq.m (Only calcium silicate false ceiling area will be measured for the purpose of payment)Notes: For Item Nos. 68 & 69 - (1) The mode of measurement shall be actual area of False ceiling and no deduction will be made for light fittings and diffusers. (2) Quoted Rate shall also includes: i) Anchor Fasteners for Drop rods.ii)Providing additional GI channel/angle/or any other suitable section for fixing of vertical member at junction of level difference in false ceilingwherever required.(3)Contractor has to submit shop drawing for the system for approval of Engineer-in-charge before proceeding with the work. (4)Work should be carried out as per manufacturers specifications andonly through approved executor/applicator and in co-ordination with the agency of HVAC /Mechanical/Electrical work and no extra will be paid for the same. (5)False ceiling workin any area should be commenced only after clearance from departmental representatitive is sought in writing for completion of HVAC ducting work. No additional claim, whatsoever, will be entertained by the Department in this regard. 109 Providing and fixing of Hollow metal fire rated (2 hr fire rating) Single leaf / double leaf doors of specified size as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates shouldbe available for vision lites /panels as part of the fire door assembly. Independent glasstest certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer of approved equivalent quality.Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening. Door shutters shall be ofG.I sheet 18 gauge thick with necessary stiffners. Thickness of the door shutter shall be as per design or minimum 40 mm). All doors and frames shall be finished with polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. 110 Extrafor providing and fixingfurniture fittings for Hollow metaldoors / Hollow metal fire door, completeas per specifications and as directed by Engineer-In-Charge. 111 304 Grade stainless steelBall bearing hinges of size 100x75x3mmor as directed by by Engineer-In-Charge withrequired screws etc. 112 Door Closer with standard arm, includingrequired screws etc. 113 Dead Lock with both side Key Cylinder 114 SS Pull - H- Type handle- 32mm Dia & 600 mm Long 115 Fire rated Clear Glass- 200mmx 300mm 116 Providing and fixing single point lock cum handle foraluminium openable windows / top hung shuttersof approved quality complete all as per specifications and as directed by the Engineer-in-charge. 117 Providing and fixing locks for aluminiumsliding window shutterswith(Over all size of 204mm x 23 mm) of approved type all as per specifications complete as directed by the Engineer-in-charge. 118 Providing wood work in frames of doors, windows, clear story openings and other frames, wrought framed and fixed in position of required size and shape including sawing, jointing,making rebates for shutters,making grooves as shown in the drawings, finishing the surfaces to the required finish all as per specifications and drawings including necessary MS hold fasts 40 mm X 3 mm thick, 200 mm long / with coach screws including protective painting to the suface that will come in contact with walls, joining materials, labour etc. complete all as per specifications and as directed by the Engineer-in-charge. 119 Second class teak wood 120 Providing and fixingFRPdoor shuttersflush door / panelled type with plain colour or wooden veneer finish of approvedquality,design & colour made out of 1.5 mm thick FRP skin moulded over wooden frame work of 40 mm wide and required thickness wooden styles and minimum100 mm wide lock rails and wooden blocks for door stoppers, tower bolts, baby latch, aldrop, handles etc. wherever required and core filled with Polyurethane Foamand fixing with 4 Nos 100 mm (ISI marked) stainless steel hinges with S.S. wood screws 121 35 mm thick panelleddoor type of approved coloursincluding the cost of 100 mm ISI marked heavy quality stainless steel butt hinges with necessary screws. 122 Providing, supplying and fixing hollow metal flush steel doors frame & shutter 40 mm thick consisting of door frame and shutters and all hardware fittings, frame of 143mmx57mm sizemade out of 1.60mm thick G.I sheets and shutters made of 1.20mmthick sheets, hollow portion filled with Honey Comb Craft paper including necessary stiffners in shutters and frame, vision panel of specified size withglass as specified. provision for fixing required hardwares, frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete / fixing in concrete with anchor fastners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge (Hardwares & vision panels will be measured under relevant Item). 123 Single Door shutter with Frame 124 Providing and fixing anodised aluminium tower bolts of size 250 X 12 mm ISI marked transparent or dyed to required colour or shade with necessary screws etc. 125 Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts complete as per specifications and as directed by the Engineer-in-charge. 126 Providing and placing in position suitable PVC water stops conforming to IS 12200for construction / expansion joints between two RCC Members and fixed to the reinforcement with binding wire before pouring concrete etc. complete as per specifications and as directed by the Engineer-in-charge 127 150 mm wide water stopper 128 Providing cement based water proofing treatment to the new terraces, chajjas, cleaning the concrete surfaces, giving injections to the top slab as required with cement and approved waterproofing compound solution to fill up all inherient holes, voids, honeycombs etc. in the concrete slab, setting brickbat coba in waterprrof mortar with necessary gradient for easy flow of water and continue the treatment along the inner faces of parapet or other adjoining wall up to a height of 300 mm in the shape of vattas, with waterproof plaster finished smooth with trovel in cement / geru with false markings of 300 mm squares complete as directed by the Engineer-in-charge 129 With Average thickness of 120 mm and minimum thickness atkhurra as 65 mm using river sand / crushed sand. 130 Average 65 mm thick for chajjas using river sand / crushed sand 131 Extra over 120 mm thick cement based water proofing for providing and laying brick bat cobain roof(i) Laying brick bats with mortar using broken brick bats 25 mm to 115 mm size with 50% of cement mortar 1:4 (using crushed sand) admixed with proprietary water proofing compound as per manufacturers specifications conforming to relevant ISand approved by Engineer-in-charge over 20 mm thick layer of C.M 1:4 (using crushed sand) to required slope complete as directed by the Engineer-in-charge.(Measurement will be over and above the average thickness of 120 mm only). 132 Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by appying cement slurry mixed with water proofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m.including injecting cemnt slurry .This layer will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound @ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofing compound conforming to relevant IS and approved by Engineer-in-charge including mixingfibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slury in bottom and all the sides of sunken portion, complete as directed by the Enginer-in-charge. The treatment to be tested for water tightness before filling the sunken areas. 133 Providing, painting and finishing walls with two coats of exterior emulsion painton sand face plaster /plain plaster & concrete of required shade over new work including base coat of water proofing cement paint, preparation of the surfaces, scaffolding complete as per specifications and as directed by the Engineer-in-charge. 134 Providing and applying wall painting two coats on new work with premium plastic emulsion paintto give an even shade, including a coat of approved cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge 135 Providing, applying wall painting two coats with Lustur paintto give an even shade over acoat of cement primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge 136 Providing and Painting twocoats of synthetic enamel paint on steel surfaces to give an even shade over aprimer coat including preparation of the surfaces, scaffolding completeas per specifications and as directed by the Engineer-in-charge 137 Providing & applyingSynthetic plaster / Textured Coating of approved quality with finishes of minimum 2 mm thickness based on synthetic fibre & chemicals having acid, alkalies, fire & fungus resistance properties of approved shade on plastered surface/ concrete surface at all levels in the same pattern of facia blocks with grooves, bands for different offsets in different colours as per approved sample including required cost of Steel Double scaffolding.The item shall include applyingapproved equivalent quality synthetic plaster with one base coat by trowelling followed by 3 coats of finished paint by brush supplied by same manufacturer, providing decorative finish as required including preperation of plastered surface to receive approved equivalent quality plaster, cleaning the surface including cost of scaffolding and cost of all materials, labour etc. complete as per manufacturers specifications and as directed by Engineer. 138 Providing and paintingTWO coats of synthetic enamel paint on new wooden surfacesof required colour to give an even shade over an under coat of suitable shadeprimerof approved brand and manufacturer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge 139 Providing and painting walls with (TWOcoats) of approved shade of high build protective , elastomeric water proofexterior gradepaint of required shade, minimium dry film thickness of 250 microns acheived in two or more coats / as per manudacturers specifications including preparation of the surfaces by scrapping / wire brush , scaffolding complete. Primer coat will be with approved make with water in ratio of 1:2and 2 coats of finishing coat without water all as directed byEngineer-in-charge. 140 Providing and applying white cement based wall puttyover concrete or Plastered surfaceup to 3 mm thickto get uniform surface free from undulationincluding cleaning complete all as directed by the Engineer-in-charge 141 Providing and Painting with Epoxy PU paintusing 2 coats of (120 Micron dry film thickness) Epoxy PU high build coating as finishing coat over a priming coat of 50 micron thickness over steel surfaces at all locations prepared and applied as per manufacturer specifications including preparation of surface by cleaning with wire brush and rubbing, scraping , applying sand paper , making free of Rust, dust, dirt etc. filling the holes, joint, cracks if any using epoxy putty complete. all as per manufacturers technical data and as directed at site to achieve minimum overall dry Film thickness of 170 micron (50 Micron primer Coat + 120 micron finishing Coat) on steel surfaces 142 Dismantlingplain cement concretemanually / by mechanical meanscarefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-in-charge. 143 Dismantling of RCC works carefullymanually without damaging adjacent structures excluding cutting of reinforcementincluding stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge. 144 Extra(over Item No. 93)for cutting of reinforcement in RCC, stacking the same and returning the steel scrap to the departmental stores all as per direction of Engineer-in-charge. 145 Dismantling of RCC works includingCuttingand stacking of steel reinforcement bars and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. 146 Demolishing C.C / R.C.C works by mechanical means and stock piling at designated locations carefully with out damaging adjacent structures and disposal of dismantled materials up to a lead of 100 m, stacking serviceable and unservicable materials separately including cutting reinforcement bars all as directed at site. 147 Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. 148 Demolishing Stone rubble masonry (In cement mortar) manually / by mechanical means carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. 149 Dismantling doors, windows and clear storey openings (steel / wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows)of area 3.00 Sq.M and below. 150 Dismantling doors, windows and clear storey windows (steel / wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows)of area beyond 3.00 Sq.M 151 Taking out doors, windows and clear storey openings (steel / wood) shutter including stacking within 100 m lead (only shutters) of area 3.00 Sq.M and below. 152 Taking out doors, windlows and clear storey openings (steel / wood) shutter including stacking within 100 m lead (only shutters) of area beyond 3.00 Sq.M 153 Dismantling steel work in single sections including dismantling and stacking within 100 m leadIn R.S Joists,Angles etc. 154 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead. 155 SECTION-G: Internal& External Water SupplyProviding and fixing to the inlet mouth of rain water pipe cast iron dome grating 15 cm diameter and weighing not less than 440 grams. 156 Providing,laying , jointing, fixing and testing heavy quality(ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples,reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cmhydraulic pressurewith a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes withISI markedC -Class heavy quality pipes. 157 15 mm dia G.I pipe 158 20 mm dia G.I pipe 159 25 mm dia G.I pipe 160 32 mm dia G.I pipe 161 40 mm dia GI pipe 162 50 mm dia GI pipe 163 Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make or approved equivalent meeting all the technical specifications as per relevant codes and standards including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge. 164 15 mm n.b. 165 20 mm n.b. 166 25 mm n.b. 167 32 mm n.b. 168 40 mm n.b. 169 50 mm n.b 170 Providing and fixing 50 mm dia brass ball cock of heavy quality of following sizes with arm rod and Plastic Ball floats completeas per specifications and as directed by the ProjectEngineer. 171 Providing and fixing 15 mm dia C.P brass bib cock of heavy qualityas directed by the Engineer-in-charge. 172 Providing and fixing 15 mm n.b. C.P Brass open stop cock of Heavy Quality as directed by the Engineer-in-charge 173 Providing and fixing 15 mm n.b. C.P brass concealed stop cock of Heavy Qualityas directed by the Engineer-in-charge. 174 Providing and fixing 15 mm n.b. C.P brass Angle cock of heavy qualityfor wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge. 175 Providing and Fixing 15 mm CP brass Angle stop cock - quarter Turn as per specifications and as directed by the Engineer-in-charge. 176 Providing and fixingCP brass / copper inlet connection pipes heavy quality suitable for hot and cold including CP brass unions and nuts 15 mm dia 600 mm long. 177 Providing and fixing 15 mm C.P brass pillarcock of heavy Quality and as directed by the Engineer-in-charge. 178 Providing and fixing heavy quality health faucetwith 1.50 metres long flexible hose (handshower) with wall brackets and type as per specifications and as directed by the Engineer-in-charge 179 Providing and fixing heavy quality 15 mm urinal flush cock as per specifications and as directed by the Engineer-in-charge. 180 Section- H: Drainage & Sanitary AppliancesProviding and fixing square mouth S.W. gully trap P type of 150 x 100 mm sizecomplete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design 181 Providing and laying non pressure NP2 class RCC Hume pipeswith collars jointed with stiff mixture of cement mortar in the proportion of 1:2, laying to the levels, slopes and as per the drawings and specifications and as directed by the Engineer-in-charge including testing of joints etc. complete 182 100 mm Dia RCC Hume pipe class NP2 183 150 mm Dia RCC Hume pipe class NP2 184 250 mm Dia RCC Hume pipe class NP2 185 300mm Dia RCC Hume pipe class NP2 186 Providing and constructioning Inspection chambers of Internal size clear dimension of 900 x 600 mm in 230mm thick brick masonry with cement mortat 1:4over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed sufaces finished with a floating coat of neat cement, brick corbelling at top to provide opening of 900 X 450 mm, embedding the frame and cover with CC 1:2:4 concrete, and fixing cast iron steps if necessary at 300mm intervals complete . Depth of chamber not exceeding 900 mm. (excavation, soling, cast iron cover and C.I steps will be paid separately under relevant item) 187 Extra depth over initial depth of 900 mm for chambers of 900 x 600 mm internal size.including fixing cast iron steps (C.I steps shall be paid under relevant item) 188 Supplying and fixing Cast IronMan hole or Cast Iron Steps, cover, grating ofweight as specified in the drawings or as directed by the Engineer in charge. 189 Providing and fixing Chlorinated PVC (CPVC) pipes having thermal stability for hot & cold water supply (as ASTM Standard 2846 & SDR - 11 Grade) including all CPVC Plain & Brass threaded fittings, fixing the pipe with clamps including chasing the walls, concealing the pipes and making good the same etc. This includeds jointing of pipes & fittings with CPVC Solvent cement & testing the joints complete all as per specifications, drawings and as directed by the Project Engineer 190 25 mm outer dia CPVC pipe (External) / open 191 32 mm outer dia CPVC pipe (External) / open 192 40 mm outer dia CPVC pipe (External) / open 193 50 mm outer dia CPVC pipe (External) / open 194 Providing and fixing PVC rain water pipes conforming to relevant IS type B and PVC SWR fittings & specialsconforming to relevant IS code including jointing with seal ring / with PVC solvent adhesive including fixing in walls usingclampsetc completeall as per drawings, specifications and as directed by the Engineer-in-charge 195 SWR PIPE 110 mm O/D 196 Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipes including required specials like bends, tees, Y collars, cowl etc for soil, waste and ventilation pipes conforming to IS:3989 or Cast iron hubless pipes conforming to IS: 15905 of approved quality including cost of jointing with spun yarn and molten lead / drip seal of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. 197 75 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint or Cast iron hubless pipes as per IS : 15905 198 100 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kglead / joint or Cast iron hubless pipes as per IS : 15905 199 Providing, supplying, fixing in position in walls Rain water down take pipes usingCentrifugally cast iron pipes (3.00 metres long) including required specials like bends, shoes etc forRain water down takepipes Conforming to IS.3989 or Cast iron hubless pipes conforming to IS: 15905 including cost of Jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes,painting with primer , fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. 200 100 mm C.I rain water down take pipe with 1.00 kg lead / joint conforming to IS:3989 /Cast iron hubless pipes conforming to IS: 15905 201 150 mm C.I . rainwaterdown take pipe with 1.20 Kg lead / joint conforming to IS:3989 /Cast iron hubless pipes conforming to IS: 15905 202 Providing and fixing Lead Sheet Flashing of about 450 mm x 450 mm size made out of 1.5 mm thick lead sheets including forming to required shape, dressing, fixing to mouth of rain water pipes with necessary bitumen, cement mortar, providing C.I. grating etc. complete as per specification for rain water downtakes of size upto 150mm n.b. 203 Providing and fixing cast iron nahani trap / floor trap of 100 mm inlet and 75 mm outlet, (weighing 5.80 Kg each), jointing with lead with the connection pipes, placing as per the drawings, embedding in cement concrete 1:2: 4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg / sq.cm pressure and fixing 1 No 125 mm dia C. P brass grating ,complete all as specifications and drawings and as directed by the Engineer-in-charge 204 Providing and fixing heavy quality stainless steel / C.P brass grating as specified for floor traps / nahani traps all as directed by the Engineer-in-charge 205 SS Grating 125 mm dia 206 Providing and fixing 150X 150 mmcast irongrating of required shapefor rain water down takes at roof includingchipping andgroutingcomplete all as directed by the Engineer-in-charge . 207 Providing and constructing storm waterchambers of Internal size clear dimension of 900mm x 600 mm in 230 thick brick masonry with cement mortat 1:4over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed sufaces finished with a floating coat of neat cement,embedding theC.I frame and cover / RCC precast slab by making suitable rebate in concrete and fixing cast iron steps if necessary at 300 mm intervals complete as directed by the Engineer-in-charge. Depth of chamber not exceeding 900 mm. (Excavation, soling, cast iron cover, C.I steps and precast slabwill be paid separately under relevant item) 208 Providing and fixing Wall Mounted EWCWhite Colour with P or S Trapwith solid seat and lid , 32 mm diaFlush Valve ,Flush bend , fixing EWC with C.P Brass screws, 15 mm PVC heavy quality inlet connection of 600 mm long, including fixing with a pair of 12 X 120 mm SS Rack Bolt, testing , commissioning & cleaning etc.complete all as per drawings and specifications and as directed by Engineer-In-Chargeat site. 209 Providing and fixing white vitreous china flat back single half stall urinal size 580 x 380 x350 mm / 610 mm with 32mm C.P flush value including standard flush pipe and C.P. brass spreaders, 32mm urinal waste coupling with dome grating and clamp etc. including making G.I water line connection complete as directed by the Engineer-in-charge (Only G.I. pipes will be paid under relevant Item )Note: For fixing flush valve 32 mm G.I water line provision to be made which will be paid under relevant Item . 210 Providing and fixing vitreous China wash basin with C.I. brackets, 15 m C.P. brass pillar tap,15 mm x 600mm longPVC Inlet connection,32 mm heavy quality C.P. brass waste couplingof standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge. 211 White vitreous China counter top/counter below wash basin size 560*410 mm/560*450 mm with single 15 mm C.P. brass pillar tap (OVAL/ROUND Models ) 212 Providing and fixing PVC low level / high levelflushing cistern 10 litre capacityin white colour with flush pipewith manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures etc. complete as per specifications and as directed by the Engineer-in-charge. 213 Providing and fixing 25 mm Dia G.I. inlet connection for flush pipe connecting with W.C. pan fromhigh level flushing cistern 214 Providing and fixing Heavy quality32 mm dia flexible PVC (semi-rigid) waste pipefor sink or wash basin including PVC waste fittings etc. complete all asper specifications and as directed by the Engineer-in-charge 215 Providing and fixing 6 mm thick mirrors of size600 x 450 mm with bevelled edges complete with 6 mm thickasbestos sheet back ground fixed to wallswith C.P. brass screws and concealedwashers complete. all as per specifications and as directed by the Engineer-in-charge . 216 Extra (over Item No. 138) for providing and fixingmirrors with - stainless steel 304 grade STUDS (with wall spacers)complete all as per specifications and as directed by the Enginner-in-charge 217 Providing and fixing stainless steeltoilet paper holderrecessed typewithS.S screws as directed by the Engineer-in-charge complete. 218 Providing and fixing 150 X150 mm soap dishofwhite viterious Chinaware,includingchasing walls making good the same after fixing the China Soap dishetc. complete all as per specifications and as directed by the Engineer-in-charge. 219 Providing and fixing heavy qualityC.P. brass waste coupling of 32 mm dia for wash basin and sink,Half threaded or Full threadedas directed by the Engineer-in-charge complete. 220 Providing and fixingheavy qualityCP brassbottle trap 31 / 32 mm ,single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal for wash basins / urinal etc all as per specifications and directed by the Engineer in charge. 221 Providing and fixing C.P brass towel rail600 mm long complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-in-charge. 222 Providing and fixing 15 mm C.P brass tube 600 mm long with nuts andwashers complete for wash basins / urinals with all necessary acessories completeas directed by the Engineer-in-charge. 223 Providing and fixing 15 mm PVC inlet connection suitable for hot and cold water 600 mm long with nuts andwashers complete for wash basins/ Urinals etc. with all necessary acessories completeas directed by the Engineer-in-charge. 224 Providing, supplying and fixing JET spray with 1.00 metre long flexible tube connection in European / Anglo Indian closet under seat cover fixtures complete all as specified and as directed by the Engineer-in-charge. 225 Providing, hoisting and installing at required elevation moulded HDPE cylindrical vertical water storage tanks of 4000 litre capacitywith WHITE SILICON coated and with suitable S. M. Ccover at top including the cost of labour for making hole in the storage tank for inlet, outlet, scour and overflow, providing and fixing necessary G.I nipples ranging from 15 mm to 50 nn n.b of average150 mm length with double check nuts, washers etc. complete as directed by the Engineer-in-charge. 226 Section-I: Miscellaneous WorksProviding and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade madewith strong vibratory compaction and approved size, shape, design laid in required colour and pattern over and including 50 mm thick compacted bed of crushed sand, filling the joints with crushed sand etc. all complete as -per the direction of the Engineer-in-charge. 227 Clearing Jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50 m / outside the periphery of the area cleared as per specifications and as directed by the Engineer-in-charge. 228 Providing and Fixing Anchor Fastner including drilling in concrete as per requirementfor fixing EPs or other structuresallas specified by the manufacturer complete all as per specifications and drawings. 229 16 mm diameter 75 mm Long 230 16 mm diameter 100 mm Long 231 16 mm diameter 150 mm Long 232 16 mm diameter 200 mm Long 233 20 mm diameter 100 mm Long 234 Providing and fixing Mechanical Splicing using threaded coupler of all types to the reinforcement bars of specified diameter and grade using high yield strength standard couplers of specially produced steel to join ribbed bearing bars machine cut end to end. Cost to include necessary supply of threaded couplers of various diametres , transportation, coupling at site by mechanical means , erection at site, testing of random samples, testing at site, protection of threaded ends using PVC covers, threading of rebars etc. complete. Cost to include necessary testing of joints ( 0.5% of the total joints) at site for tensile strength and as required by Engineer-in- Charge.Cost quoted shall include all materials and labour. 235 16 mm dia 236 20 mm dia 237 25 mm dia 238 Providing and fixing stainless steel urinal grab bar/wash basin Grab bar (confirming to grade SS 304, satin finish) consisting of 38 mm dia. 18 SWG stainless steel pipe duly bended in required shape and size, hinged with 3mm thick stainless steel rectangular sheet of required size having 6 nos. holes and u shaped stainless steel clamp for holding the grab bar including cutting, bending welding grinding, polishing and fixing with suitable sized and nos. of dash fasteners complete as required. All bends to be neatly finished miter joints complete etc. as required. 239 Labour charges for dry stone pitching 22.5 cm thick by using good soling stones available at site, preparing the surface complete. 240 Part-II : Mechanical Works Split AC units : Supply, installation, testing & commissioning of split AC of followingnominal capacity and accessoriesas per tender specifications 241 2TR 242 1.5TR 243 1TR 244 Copper pipe with insulation :Supply and installation of Copper pipe with insulation suitable for following capacity split ACmachine (quantity for single run ) 245 2TR 246 1.5TR/1TR 247 Drain pipe: Supply and installation of5/8 inch dia PVC Braided flexible pipe withinsulation as per tender specification. 248 Casing capping : Supply and installation of PVC casing-capping of following cross sectional size as tender specification. Location : for AC pipe and drain 249 150mm x 50mm 250 100mm x 50mm 251 Electric cable:Supply and installation of Electrical wiring/cables of three/four core x 2.5 mm² (or as per split AC requirement foritem no 155) 252 Exhaust fan: SITC of propeller type exhaust fans with louvers offollowing sweep dia ( approx.) along with all accessories and fixture as per tender specifications. 253 200mm 254 300mm 255 Part-III : Electrical Works Lighting Distribution Board as per TSS1 256 Power Distribution Board as per TSS2 257 10way VTPN DB with 160A Incomer as per TSS3 258 8way VTPN DB with 63A Incomer as per TSS4 259 4C 25sqmm Al conductor XLPE cable as per TSS 5 260 20 Pair Telephone cable as per TSS6 261 Optical fibre cable as per TSS7 262 4pair instrument cable TSS8 263 End Termination of 4C 25sqmm Cable as per TSS9 264 End terminations of 20Pair Telephone as per TSS10 265 End terminations of Instrument cable as per TSS11 266 Point Wiring for below points as per TSS12 267 Primary Power Points (16A+6A) 268 Secondary Power Points 269 Primary Lighting Points 270 Secondary Lighting Points 271 Highbay Primary Lighting Points 272 Highbay Secondary Lighting Points Secondary 273 Terrace lighting Primary points 274 Terrace Secondary lighting points 275 Primary Security Lighting Points 276 Secondary Security Lighting Points 277 Primary Ceiling Fan Pointswith switch and regulator 278 Secondary Ceiling Fan Points with switch and regulator 279 Primary Exhaust Fan power Points 280 Secondary Exhaust Fan power Points with switch and socket 281 Split AC Power Points 282 Primary FA/PA Points 283 Secondary FA/PA points 284 Point wiring for call station point 285 Network combo points 286 LED Recess type Lighting Fixtures as perTSS13 287 LED square type surface Lighting Fixture as per TSS14 288 LED Lighting Fixture Highbay type as per TSS15 289 Outdoor Security LED Lighting Fixture as per TSS16 290 LED Terrace Lighting Fixture as per TSS17 291 LED Flood Lighting Fixture as per TSS18 292 LED Batten Lighting Fixtures as per TSS19 293 42U Mounting Rack with accessories as per TSS20 294 15U Mounting Rack with accessories as per TSS21 295 24 Port rack mount LIU with splicing of OFC as per TSS22 296 24 Port Jack Panel as per TSS23 297 3 Feet Patch cord (CAT 6) as per TSS24 298 Earthing Stations as per TSS25 299 Fire Alarm Terminal Box as per TSS26 300 PA Terminal Box as per TSS27 301 Perforated Cable Tray (size 300 mm X 50mm) with accessories as per TSS 28 302 Cu Earthing wire 8 SWG as per TSS 29 303 Air Terminal as per TSS 30 304 Test Link with Enclosure as per TSS31 305 MS fabrication item as per TSS32 306 MS Powder coated item as per TSS33 307 Self Illuminated signage as per TSS34 308 GI Sleeve as per TSS35 309 GI 25 X 6 mm Earthing strip as per TSS36
Contract Date: Jan 23, 2026 Contract Value : 3.33 Crore
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Jan 07, 2026 Contract Value : 51.41 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
10.
Defence #8044738 AOC
Tender For Provision Of Wksp Repair Est At Leh Under Ge I P No 1 Leh; 1 NOTE: Schedule ‘A’ Part - ItoPart -XIIare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 2 Total amount of Sch A Part - I (BUILDINGS) 3 Total amount of Sch A Part - II(SITE CLEARANCE WORKS) 4 Total amount of Sch ‘A’ Part - III (PROTECTIVE WORK) 5 Total amount of Sch ‘A’ Part - IV (ROAD WORKS) 6 Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL WORKS) 7 Total amount of Sch ‘A’ Part - VI (SECURITY WALL WORKS) 8 Total amount of Sch ‘A’ Part - VII (INTERNAL WATER SUPPLY WORKS) 9 Total amount of Sch ‘A’ Part - VIII (INTERNAL ELECTRIC SUPPLY WORKS) 10 Total amount of Sch A Part - IX (EXTRNAL WATER SUPPLY WORKS) 11 Total amount of Sch A Part - X(EXTRNAL ELECTRIC SUPPLY WORKS) 12 Total amount of Sch ‘A’ Part - XI ( STREET LIGHT WORKS) 13 Total amount of Sch ‘A’ Part - XII ( STANDBY DG SET FOR CHS WORKS) 14 SCH A PART - XIII(Miscellaneous B/R and E/M works for Sch A Part-II to Part-XII)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 15 Supplying and fixing30 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional typecomplete all as specified and directed by Engrs-in-Charge. 16 Supplying and fixing 10 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional type complete all as specified and directed by Engrs-in-Charge. 17 Construction of soakage well 2.4m internal dia and3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings. 18 Construction of soakage well 1.2m internal dia and3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings. 19 Supplying and fixing for Concertina Coil Punched type 610mm dia razor type made out of 2.50 mm dia SG hot galvanised spiring tensile wire 145 to 150 N/SQMM zinc coating 240 gms/sqmm (min) weight of coil shall be minimum 8.57 kg/coil shall be 6.25 RM after laying, min Nos of turns in each coil shall be of 49/50. Galvanized razor ribbon type shall be of size 0.50 mm thick, 19 mm side before wrapping on central core wire. Concretina coil shall be fixed to existing angle iron swan neck supports using GI clips 125 to 127 Nos per coil and special nuts and bolts for holding Z coil together and extra two rows parallel wire of 10 gauge etc all as specified. 20 M & L for MS wicket gate as Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge. 21 M & L for 5.5 Mtr Wide gate with pillers Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge. 22 Supply, Install, lowering, testing, and commissioning of submersible openwell pumping sets, centrifugal, electric driven,minium discharge of 23.46 LPM at 33 mtr headmotor capacity minium 3 HP including 3 HP Starter complete all specified and directed. 23 Supply, installation, testing and commissioning of LT Feeder Pillar Box, out door type, vermin proof, front dooropenable, made out of CRCA Sheet 3.15 mm thick, duly powder coated, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following.a) Bus bar chamber with and including copper strips (set 4 nos) suitable for 100 amps duly insulated wired & duly mounted on porcelain insulators b) Incommer MCCB 4 Pole 440 Volts, 40 Amps rating with repturing capacity 16 KA - 1 Noc) Outgoing MCCB 4 Pole, 16 Amps rating with repturing capacity 16 KA - 2 No (for Openwell Submersible pumpset)d)Three Ph LED electronic Ammeter Class 1 with in built selector switch having range 0 to 100 Amp - 01 Noe) Three Ph LED electronic VoltmeterClass 1 with in built selector switch having range 0 to 500 Volts- 01 Nosf) Indicator RYB . LED type- 1 Set.g) All accessories prewired with appropriate size copper strip or wire thimbles etc. 24 h) Space for Provn of DOL starter 3 HP - 02 NosAll as required including foundations as per Manufacturers recommendations all as required at siteor as directed by Engr-in-Charge. (j) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 25 Supply and fix submersible copper conductor cable 3 core, 4 sqmm 1100 volt flat industrial grade including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe complete all specified and directed. 26 M&L for Construction of brick masonary valve pit of size.0.9X0.9X1.8 mtr (internal diamensions) including excavation and earth work in any type of soil, PCC 1:4:8 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame 40X40X6mm,with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer, filling saw dust into the pit and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle all as specified and directed by Engr-in-charge. 27 Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.5m x 1.2m x 0.7m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Main LT Panel)(Near Prop Transformer)(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 2400 Amps.(b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Amps - 01 No for incoming(c) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 28 (c) MCCB 4 Pole, 415 V, 36 KA, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 02 No O/G (for Prop Sub LT Panel, Spare)(d) ACB 800 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No O/G (for CHS LT Panel) (e) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 03 No O/G (for High Mast light No.1,2 & Feeder Pillar box)(f) Indicator Lamp LED type (RYB) - 01 Set (g) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 1600 Amp including suitable rating CTs -01 Set(h) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(j) All accessories prewired with appropriate size copper strip or wire thimbles etc.All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. 29 Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.2m x 1.2m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Sub LT Panel)(Near workshop bldg)(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 1000 Amps.(b) MCCB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 01 No for incoming(c) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 30 (c) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No O/G (for VTPN DB No.1)(d) MCCB 63 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 Nos O/G (for VTPN DB No 2)(e) MCCB 160 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 Nos O/G (for VTPN DB No 3)(f) MCCB 100 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No O/G (for VTPN DB No 4)(g) Indicator Lamp LED type (RYB) - 01 Set (h) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 600 Amp including suitable rating CTs -01 Set(j) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(k) All accessories prewired with appropriate size copper strip or wire thimbles etc.All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. 31 Supply, installation, commissioning and testing of factory made, CPRI approved feeder piller box of size 0.9m x0.9m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including fwg:- (Feeder Pillar box) (Near washing platform) 32 (a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 50 Amps.(b) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No incomer(c) MCCB 16 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No outgoing(d) Earth plug socket 3 ph 415 V, 32 Amp - 01 No(e) Switch socket combination 5/15 Amps 5/6 pin - 02 Nos(f) Indicator Lamp LED type (RYB) - 01 Set (g) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 400 Amp including suitable rating CTs -01 Set(h) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(j) All accessories prewired with appropriate size copper strip or wire thimbles etc.All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. (k) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 33 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 34 Supply, Installation, Testing & Commissioning of High galvanized mast light suitable for 8 luminaries symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation suitable for 12.5 Mtr height completed minimum dimension specified as under mentioned specifications.Note : As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule.(A) High Mast Structure1. Matrial of Construction:- HR sheet steel conform to IS 2062/BS EN 10025 or Equivalent2. Base Dia. and top diameter (A/F) 1. Top Section - 150 mm 2. Bottom Section - 360 mm3. Plate thickness :- Top - 3mm, Bottom - 3 mm4. Cross Section of Mast (Number of Slides) - 20 Sided Polygon5. Standard of galvanisation - As per BS EN ISO 14616. Size of opening and door at base - 1050 x 225 mm7. Diameter of base plate - 520 mm8. Thickness of base plate - 25 mm9. Lighting protection finial - G.I single spike 35 10. Max. wind speed - 50 m/s as per IS : 875 (Part -III)11. Number of foundation bolts - 4 nos12. Type/ diameter/ length of foundation bolts - TS 600/ 24 mm dia/ 850 mm long13. PCD of foundation bolts - 445 mm(B) Luminaires Carriage :- 1. Material of construction - 40 NB ERW Class B - M.S. pipe2. Diameter of carriage ring (mm) - 450 mm (ID)3. Construction - 4 Arm, welded, 2 sections4. Load Carrying capacity - 08 Luminaires(C) Trailing Cable :- 1. Conductor - Copper, 5 core, 2.5 Sqmm 2. Insulation -PVC insulated3. No of circuits per mast - One no. cable per mast (D) Winch/ Power Tool1. Type /SWL of winch - Double drum, SWL 350 Kg2. Method of seperation - Integral Motor3. Motor capacity - 0.75 HP4. No of speeds - 6 pole, single speed5. Torque limitor - with mechanical tripping facility(E) Stainless steel wire rope 1. Grade/ Construction - AISI 304, 7/19 construction2. No of ropes - Two continuous3. Diameter (mm) - 5 mm4. Breaking load capacity - 1350 Kg x 2 36 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 250 Amps rating with rupturing cap 36 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 37 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 38 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 39 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 40 S & F, installation, commissioning and testing Junction boxes made of Lid PC and base is polystyrene Hensel reference : KG series suitable . Junction Boxes Size 217 x 253 x 115 mm in Grey RAL 7035 colour. Junction Box IP 65 Thermoplastic PS Polystyrene weatherproof Junction Box with multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the junction box to enable cable entries from both direction. The junction box shall have an optional cable entry at the bottom up Cable Size 25 Sq mm of the box via pre-moulded knockout to enable pole mounting option. Lid fasteners self closedwill be tool operated. it will be sealable with accessories. The junction box shall have elongated holes inside them for wall/pole mounting provision. The junction box with 4 Pole Terminal Strip and MCB SP 6 Amp 10 KA C Curve for LED light. In the event of formation of condensed water, the junction box shall have a minimum of two condensation knock-outs inside to ensure optimum safe performance. 41 The junction box shall fulfill the following standardsWeatherproof : Rainwater proof, temperature resistant.IEC 60670-22 : Particular requirements for connecting boxes and enclosures.IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C.IEC 60529 : IP 65 degree of protection.UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4The Junction Box with Suitable Glands 3 Nos with each andchromium plated clamps, nut bolts complete all as per manufacturer’s instructions. 42 Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (Main LT Panel )INCOMING:(a) Aluminium bus bar 3 phase 4 strip suitable for 600 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves- 01 No.(b) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 16 Amps - 01 No Incomer 43 OUTGOING:(c) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 10 Amps - 02 Nos O/G(d) Indicator Lamp LED type (RYB) - 01 Set (e) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 100 Amp including suitable rating CTs -01 Set(f) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(g) All accessories prewired with appropriate size copper strip or wire thimbles etc.(h) All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. 44 Supply & installation of silent CPCB4 approved 625 KVA TPDiesel Generating Set having diesel engine Liquid cooled, Electric start, four stroke, cold starting, TCI Aspirated, compression ignition, totally enclosed diesel engine with electronic governor , direct coupled ith 625 KVA Three Phase alternator at 1500 RPM, 0.8 lagging power factor, providing Three Phase 415Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS5000, IEC: 34 and suitable for tropical condition. having fitted inside Canopy, fabricated out of 1.6 mm CRCA Sheet, cubical type, totally enclosed, Powder Coated, Control Panel and all accessories in- housed in a acoustic enclosure – sound proof canopy. 45 (A) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- 46 i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Water pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre. Exhaust gas turbo charger type, Exhaust manifold, Silecer : Residual type, Bellows 47 iv) Fule System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governer for 1% speed /frequecy regulation. Fuel filters, Fuel hosesv) Lub oil System :-Lubricating oil filter, Lubricating oil pumpvi) Air Intake System :- Air intake Manifold, Air cleanler dry type, vii) Governer :- Electronic Governer, viii) Starting System :- Electric Self starter with maintenace free battary including battary charging alternator. 48 (B) Batteries :- 24 VDC system 2x180 AH Batteries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistrnded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified of Make as per OEM.D) Starter gear ring, Start and stop push button, Ignition key / Switch, Handling and operation : Salient features of accessories shall be as under, Radiator with blower fan, Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass. Electronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel. 49 (C) Generator Monitoring Control Panel : - Comprising of all standard items as mentioned under this schedule or as per standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display including suitable size MCCBs and multifuction meter.xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling. 50 xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames.xiv) Base Frame with anti vibration pads on base frame: - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes.xv) MS pipe line to and from the fuel tank to the DG Set.(D) Alternator :-Standard design alternator rated at 625 KVA,net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class H and voltage regulation of+ 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. 51 i) Insualation class - H, ii) Temparature rise Class - H, iii) Excitation : Self Excited, iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% . v) Frequency regulation + 1%F). Civil Works :- All civil works including PCC plat form as per manufactures design also 30 cm above the ground. The depth of the foundation and PCC as recommended by the manufacturer. G) Rubber Mattingof LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided.Note:- The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. 52 (E) Accoustic Enclosure:- Manufactured by OEM suitable for 625 KVA DG Set. (i) NAL approved as per CPCB(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattaries and control panel should be inside the enclosure.(iv) Fuel tank should be out side the enclosure in the sub station building.v) The DG Set should be provided with external Emergency stop push button.vi) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulatedplatform.viii) The enclosure should be suitably illuminated by suitable capacity of LEDfittings.xi) The noise level should be 75 db at 1m under free field conditions. 53 xii) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.xiii) Fuel tank as per manufacturer recommendation with inlet and outler connections and fuel level indicator.NOTE : - (i) TheGenerator set prime mover will produce at least 734 BHP on 625 KVA.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to distrbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first filling of lubricant oil. (iv) The quoted rate shall be deemed to be inclusive of 24 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer; including FOL, all arrangements are to be made by the contractor for tests. 54 Supply and fix off LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 1000 Amps complete all as specified and directed. 55 Supply and fixing LED blub full dum 7 watt with rechargeble type, retrofit all as specified and directed by Engr-in-charge 56 S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 100 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) 57 S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 200 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) 58 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, toughned glass, 240V, IP 66 class, impact resistence IK07, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 59 Supply and Fixing of 40W LED High Bay light with Surface mounted device(SMD) with multiple LED with Borosilicate glass lens and acrylic, with aluminum reflector,operating Voltage between 140-270Vac, Power Factor more than 0.95%, intergal driver with 3KV surge protection differential mode/coman mode ,LED CCT 5665±355K as per ANSI BIN, Over load protection,No load Protection, Driver should be concealed under IP66 and BIS Marking (R no. for Driver), Driver Certiifcation IEC64347-2-13 IS(15885), System Lumen >4000, CRI>70, Over all electrical efficency more than 90%,connecting with PVC copper cable of size 3x1 sqmm at least 2 Year on site warranty wihout any condition including taking down of old light fitting safely and removing from site complete all as specified and directed. 60 SCH A PART - XIV(HOT WATER SUPPLY)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 61 Supply and fixing of 5 star rated Water Heaters Storage type (Geysers) of Capacity 25 ltrs including grouting the nuts, bolts, washers of adequate size and all other accessories required at site for the effective functioning of the water heater complete all as specified and directed.Note :(i) Cost of Stop cocks deemed to be included in the quoted rate no extra payment shall be made.(ii) PVC connections, Bib cock and GI pipe shall be measured and paid seperately. 62 S&F BIB TAPS, chromim plated cast copper alloy with capstain head, screwed for 20mm bore dia iron pipes or for brass ferruble and fixed complete all specified and directed. 63 S&F PVC connection 15mm dia with PTMT nuts of length 450mm complete all as specified and directed. 64 SCH A PART - XV(CENTRAL HEATING SYSTEM)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 65 Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 150 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 66 (a) All neccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(b) The prices should include lifting, shifting and positioning of units at Site.(c) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer. (d) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity as per ISO or equivalent standard.(e) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 67 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with EFF1 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below: The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 68 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM.(ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) 3 Nos.- 150 mm dia type pressure gauges(iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation)(v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Pump capacity are as under:(vii) Capacityand pump headnot less than flow 350 USGPM , Head 35 mtr each including the triple duct valve and End Suction guide. Note:- In 02 Nos working and 01 No standby configuration. 69 EXPANSION TANK and Pressurisation Unit: Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. 70 The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. 71 The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 1000 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). 72 (a)Expansion Tank of 1000 Lts capacity for bldg 73 (b)PRESSURIZATION UNIT: for Pump Set -03 Nos (Ref. Point 4) with Control Panel and accessories for bldg. 74 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 990 litres for Pocket-1complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 75 Supply, Installation, Testing and Commissioning ofCeiling Suspended Fan Coil Unit having casing with bottom return Air Plenum complete including Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with inbulit 2way wall withcordless remote. The Ball Valve with Strainer/ Shut off Value with Strainer at inlet and outlet of FCU including copper connection pipe for inlet and outlet should be provided. The Unit Capacityshould becalculated as per BIS/ Eurovent Standard/AHRI Certification method.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 65 Degree Celcius , OUTLET TEMP: 55 Degree Celcius and Below Mention External Static Pressure (ESP). 76 2.5 kW,ESP: 50 Pa (Reference Model No.:FWW200VC / Equivalent)(CHS Plant Room - Toilet ) 77 5 kW,ESP: 50 Pa (Reference Model No.:FWW500VC/Equivalent) (Wkshp Toilet Area - 4 Qty, CHS Plant Room - Toilet- 1 Qty) 78 10kW,ESP: 50 Pa ( Reference Model No.:FWW1000VC/Equivalent)(Staff Room: 2 Qty, SPL Shop, Tech TRG, Tech LIB, Inspection OFF, Office for Wksh- 1 Qty 79 12 kW,ESP: 100 Pa( Reference Model No.:FUW015A/Equivalent)(Electricain - 1 Qty) 80 18kW,ESP: 100 Pa ( Reference Model No.:FUW020A/Equivalent)(Office for QC n Fuel Injection - 1 Qty) 81 24 kW,ESP: 100 Pa( Reference Model No.:FUW030A/Equivalent)(Mech Section- 1 Qty) 82 30kW,ESP: 100 Pa (Reference Model No.:FUW035A/Equivalent)(Service Bay - 2 Qty Each Service Bay) 83 M & L for Pre - insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 84 Inside Building 85 100 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 86 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 87 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 88 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 89 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 90 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 91 Buried under ground/Exposed to Ambient: 92 100 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 93 80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 94 Supply,Installation, Testing amd commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports, jointinginsulated with XLPE class O tubular insulation and any other item required to make the system compelete. Nominal diameters of pipein mms as inducated below: 95 25 mm dia pipe, Insulation thickness - 19 mm 96 32 mm dia pipe, Insulation thickness - 19 mm 97 40 mm dia pipe, Insulation thickness - 19 mm 98 CABLE TRAYS 99 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 100 150 mm width X 50 mm depth X 1.6 mm thickness 101 VALVES : 102 Supplying, fixing, testing and commissioning of following diameter valves(PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 103 100 mm dia Butterfly Valve 104 65 mm dia Butterfly Valve 105 Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. 106 65 mm dia Y STRAINER 107 NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified. 108 65 mm dia NRV 109 Automatic Air Purge Valves forhot water circulation headeras specified and required by Engineer In Charge. 110 Automtic Air Purge Valve 20 mmdia 111 Air Separator (PN16) 112 65 mm 113 SITC of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 114 SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 115 Supply, installation, commissioning and testing of factory made, CPRI approved LTCHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 116 INCOMERS(a) Bus Bar TPN Copper extensible type main bus bars of minimum of1200 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(b)ACB 800 Amps, 415 Volt, 50 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers) Make: Legrand/Schenider/Simens 117 OUTGOINGS(c) 4 Nos- 400A 10 KA TPNMCCBwith Microprocessor release (3# Hot Water Generator) (d) MCB 5/6 Amp, 10KA, TPN - 02NosPressurization PUMPs (e) MCB 50 Amp, 10KA, TPN - 03 Nos for Pumps(f) MCB 5/6 Amp, 10KA, SPN,- 07No for Bldg load/FCU. Makes of MCBs: Legrand/Schenider/Simens(g) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set 118 (h) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(j) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing of panel to GE before execution for approval. 119 Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed Copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray) 120 3.5 Core x 250 sq.mm. (Electric Hot Water Generator) 121 4 Core x 10 sq.mm. (Pump) 122 4 Core x 6 sq.mm (Pressurization Unit) 123 2 Single corex 2.5 sq.mm. (FCU) 124 4 Core x 4 sq.mm (Boiler Pump) 125 Earthing complete with GIearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge. 126 Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size2m * 1m * 25 mm complete all as specified & directed by Engr-in-charge. 127 Supplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels for CHS complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. 128 GENERAL NOTES:- 129 1. The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of :(a) All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.(b) Wastage on materials and labour.(c) Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles. 130 (d) Liabilities, obligations and risks arising out of Conditions of Contract.(e) The unit rate for all equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required.2. The contractor shall perform Nitrogen test and vacuum test on refrigerant piping. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by consultant / client’s representative. 131 3. Cable glands shall be compression type, heavy-duty chromium plated.4. All cable termination to have lugs/ thimbles.5. INSTRUCTION / MAINTENANCE MANUAL 132 The Contractor shall prepare and produce instruction, operation and maintenance manuals in English for the use, operation and the maintenance of the supplied equipment and installations and submit to the Client / Consultant in (3) copies at the time of handing over. The manual shallgenerally consist of the following:(i) Description of the project.(ii) Operatinginstructions.(iii)Maintenance instructions including procedures for preventive maintenance.(iv) Manufacturers catalogues.(v) Trouble shooting charts.(vi) Schematic & control wiring diagrams. 133 (vii) Commissioning Certificate.(viii) Also for BMS System, Training,Opeartion, Installation manual and Trouble shooting manual and Training should be imparted to the field person.(ix) Allneccassary license should be provided for the BMS free of cost.6. For Make List If any make stated below does not comply with the technical specifications and or IS Standards then such a make shall not be used in the work. 7.MAINTENANCE OF PLANT AND TRAINING OF PERSONNELThe Cont ractor shall arrange to provide, at no extra cost, necessary personnel and material to carry out all routine maintenance of the CHS equipment as required regularly.
Contract Date: Sep 30, 2025 Contract Value : 10.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
11.
Housing Urban and Rular Development #7636343 AOC
Tender For Dd - Mumbai City-Marol (Mmr Zone- I) Industrial Area...Dc Work… Refurnishing Work Of Mitl Office At B Wing First Floor In Udyog Sarathi, Andheri - Demolition & Civil works 2 Removing doors and windows with frames and stacking thematerials as directed withall leads, lifts etc. complete. 3 Removing wooden, glass or A.C.partition including frame work and stacking the materials as with all leads, lifts etc. complete. 4 Removing false ceiling in all types of ceiling i.e. Gypsum, Accoustical, Calcium silicate board, metal etc. including stacking the materials as directed with all leads & lifts. 5 Dismantling Brick Masonry in lime or cement mortar and stacking the material as directed with all leads & lifts complete. 6 Removing the existing cement plaster with POP/Putty of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. 7 Removing brick bat coba including stacking the spoils as directed with all leads, liftsetc, complete. 8 Removing cement tiles, or marble or polished shahabad floor or dado or platform without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 9 Dismantling old electrical fixures of all types i.e. switch boards, lights, smoke detectors etc. including its wiring and stacking of serviceable material and disposal of unserviceable material with all lead and lifts. 10 Dismantling old sanitary fixures of all types i.e. W.C., urinals, wash basin etc. including its pipes and stacking of serviceable material and disposal of unserviceable material with all lead and lifts. 11 Dismantling old Sprinkler Sysytem and Air condition (any types) unit indoor, out door, all types Ducting, Grills,diffuser,fastner,rods,of all types of various sizespipes Fexible pipes, etc. including its wiring and stacking of serviceable material and disposal of unserviceable material with all lead and lifts. 12 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 13 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 14 Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years guarantee on requisite stamp paper including curing etc. complete. 15 Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. 16 Providing and laying in position Cement Concrete 1:3:6 (one cement : 3 coarse sand : 6 graded stone aggregates of 12/20 mm nominal size). transported to site of work in Mannulfor all leads and lifts on 5th floor, having continuous agitated mixer, Mamanufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the EIC/Architect. 17 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. 18 Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 19 Providing and laying 4 mm to 6.5 mm thick PVC plank flooring of approved make,made of 100% virgin PVC/ SPC backing with minimum 0.30 to 0.50 mm thick wear layer in required design and pattern in linear and curvilinear portions of the building. The planks are to be connected with glue free click connect joinery system and junction of the adjoining floors are to be finished with T or any other approved profile of aluminum/ wooden/ S.S. of approved make as per manufacturers specifications. The entire work is to be completed as per the direction of the EIC/Architect. 20 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. 21 Providing & fixing 100% Nylon based solution dyed tufted loop pile carpet tiles of approved size, make & pattern having minimum pile weight of 600 gm per sqm and minimum pile thicknesss of 2.5 mm in flooring over smoth & damp proof base using rubber based adhesive of approved quality & make completewith T or any other approved profile of aluminum/ wooden/ S.S. of approved make as per manufacturers specifications. The entire work is to be done as per manufacturers specifications & directions of the EIC/Architect. Basic rate of Carpet: Rs.1800/- Per Sqmt 22 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm / 300 x 600 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete 23 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. 24 Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) 25 Sub Estimate No. 2 - Plumbing Works 26 Providing and fixing chlorinated Poly Vinyl Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 mtr spacing.This includes jointing of pipe 27 15mm nominal OD pipe 28 20mm nominal OD pipe 29 Providing and fixing 15 mm dia Piller cock with guarantee against any manufacturing defect including socket, union nuts etc. complete. As per direction of Engineer - in - Charge. 30 Providing and fixing European type commode including outlet, inter connections through walls including all fittings etc. complete.As per direction of Engineer - in - Charge. 31 Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 32 Providing and fixing in position UPVC Nahani Trap includingSS grating,fixing in cement concrete M-15 etc. complete.. b) 110 mm. size 33 Providing and fixing soap dish with all types of fixtures including labour charges including transport charges etc. complete. 34 Providing and fixing 15 mm dia 2 Way BIB cock long body with flange,guarantee against any manufacturing defect including socket, union nuts etc. complete.As per direction of Engineer - in - Charge. 35 Providing and fixing Jet Spray withguarantee against any manufacturing defect including socket, union nuts etc. complete.As per direction of Engineer - in - Charge. 36 Providing and Fixing of Mirrors in TOILETS of approved Indian quality,with under layer foam (hitlon) with S.S.bracket /studs 12mm thickdia top & bottom in the masonry etc. complete.As per direction of Engineer - in - Charge. 37 Supplying, Providing and fixing in position of approved make first quality, recessed, roller type or box type white glazed toilet paper holder 150 mm x 150 mm size etc. 38 Providing and laying UPVC pipes of standard make in line and level including necessary labour, bends, tees, fixtures etc. and testing the pipes complete. 39 100 mm diameter 40 75 mm diameter 41 62 mm dia 42 Providing and fixing Chromium Plated Alluminium Towel Rail 750 mm (26) long, 20mm (3/4) dia and of approved quality fixed on chromium plared bracket including providing teak wood gutties in masonry etc complete as per direction of Engineer - in - charg 43 Providing and fixing 15 mm dia Angle cock with guarantee against any manufacturing defect including socket, union nuts etc complete as per direction of Engineer - in - charge. 44 Providing and fixing in position Double coat hooks as per instructions from EIC/Architect 45 Providing and fixing in position Hand dyrer as per instructions from EIC/Architect 46 Providing and fixing in position SS sink for kitchen / pantry as per instructions from EIC/Architect 47 Providing and fixing 15 mm dia Piller cock for Sink with guarantee against any manufacturing defect including socket, union nuts etc. complete. As per direction of Engineer - in - Charge. 48 Providing and fixing in position CP brass concealed stop-cock with adjustable wall flange etc., complete as per drawings and instructions of EIC/Architect. 49 Providing and Fixing White glazed vitreous Chinaware urinals with integrated sensor including all fittings like CP brass flush pipe, CP brass spreaders with unions and clamps (all in CP brass), CP brass waste coupling 40 mm dia, inlet connection, concealed Z CI brackets etc., all complete including cutting and making the good the walls and floors wherever required as per the architectural drawings, manufacturers specifiaction and as directed by the EIC / architect complete in all respects. 50 Providing and fixing frameless urinal partition of approved make made of 8 mm thick toughned glass. Rate includes patch fittings etc., as directed by the EIC / Architect. 51 Providing and fixing in position brass heavy duty gate valve 20 mm dia of zoloto make confirming to IS:778 with sockets, nuts and bolts etc., complete. 52 Sub Estimate No. 3 - Painting work 53 Providing & Applying Plaster of Paris Punning in average 12 to 25mm thickness to walls, ceiling, beams & columns to bring the surface in plumb Line & Level including making the surface smooth, providing required grooves on top of skirting etc. complete as per directions of Engineer - In - Charge. 54 Providing & Applying superior quality of Luster Paint of approved make & shade, using roller to get approved textured surface in 3 or more coats including preparation of surfaces, applying cement primer of approved make & shade etc. complete as per directions & manufacturers specifications & instructions of Engineer - In - Charge. 55 Providing and applying plastic emulsion paint conforming to IS:5411-1991 part I of superior quality of approved make, colour and shade to the old & new surfaces in two coats over primers, including scaffolding, preparing the surfaces to receive the paint and applying putty etc. complete. 56 Finishing with Multi surface Zinc paint After surface preparationapplyingone or more coats of zinc based coat comprising of Zinc powder mixed with suitable medium in proportion1: 2 (One part of medium : 2 parts of zinc powder)@ 2.5 litre/10 sqm or as directed by Engineer-in-Charge andone coat of special primer applied @ 0.75 ltr /10 sqm over zinc coat. Top layer with two or more coats of approved luster paint/multi surface paint @ 1.25 ltr/10 sqm including preparation of surface even and smooth etc complete as per direction of Engineer-in-Charge 57 Providing and applying wash able oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. 58 Sub Estimate No. 4 - Carpentry Works. 59 Providing and fixingin position Aluminium Frame Work of Square hollow sections of given size for partitions, paneling, boxing, soffits etc. with vertical & horizontal members at not more than 600 mm center to center. All complete including necessary additional supports, bracing, runner etc. so that lateral movement is arrested. as per instructions of Architect. Frame work will be measured and paid as per actual measurement on site. Rates quoted shall include the cost of providing and fixing supports up to ceiling. All complete as per detail drawing, as specified and as directed by Architect. 60 Size 50 x 25 x 1.62 mm 61 Size 50 x 50 x 1.62 mm 62 Providing & Fixing in position on existing frame work including all materials, labour etc complete. Item to be completed in all respects as per drawings & instructions from Engineer - In - Charge. 63 9mm thk Marine plywood 64 12 mm thk Marine plywood 65 19 mm thk Marine plywood 66 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 30 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. 67 Providing and fixing 3mm - 4mm thick group matching Decorative Veneer of approved quality and make, of required size and width as per site condition including surface preparation pasting with approved adhesive and finishing it evenly to get flat surface. The cost of openings for switches, AC Facia, any other cutout etc. shall be included in the rates quoted. complete as per detail drawing & directions by Architect. No extra payment will be made towards providing any pattern .The item includes finishing the surface with 3 or more coats of melamine polish, molding, lipping patti of all size etc and any material required to complete works as per the direction by Architect. (Basic Rate for veneer: Rs.180 per sft.) 68 Providing and fixing 1.5 MM thick group matching Laminate of approved quality and make, of required size and width as per site condition including surface preparation pasting with approved adhesive and finishing it evenly to get flat surface. The cost of openings for switches, AC Facia, any other cutout etc. shall be included in the rates quoted. complete as per detail drawing & directions by Architect. No extra payment will be made towards providing any pattern .(Basic Rate for laminate: Rs.55 per sft.) 69 Providing & fixing in position 460 mm deep storage / Wardrobe unit along with partitions etc with 1) sides,top,bottom shelves made out of 19 mm marine plywood 2)6 mm thk. marine ply backing panels3) Shutters made out of 19 mm thick block board &6 mm thick teakwood leaping with egde moulding of approved profile if any shall be provided in all exposed ply edge surfaces & be finished with melamine polish / PU coating.4) Finish 1mm thk laminate inside &4mm thk veneer out side as per below mention, hardwares such as heavy duty hinges of size 100 x 19 x 25 mm, brass body locks(Elpro make) with extra large group key of approved quality, magnetic ball catchers, handles of dia 12mm x 128mm, towerbolt 150mm etc. All exposed woodwork to be finished with 3 coats of melamine polish / PU coating & all internal surface finished with approved 1 mm thk laminate. All as per detailed drgs and instructions of EIC / Architect. Size in front elevelation will be measured for payment. 70 Full height storage with veneer finish (FST) 71 Low height storage with Veneer finish (LST) 72 Over Head Storage with Laminate finish 73 Consul-unit 450MM Deep. 74 Full height storage with Laminatefinish (FST) 75 Low height storage with Laminatefinish (LST) 76 wardrobe storage 77 Compactor 78 Storages Providing & fixing in position 460 mm deep storage/Wardrobe unit alongwith partitions etc with 1) sides, top, bottom shelves made out of 19 mm marine plywood for all inside surfaces 2) 6 mm thk. marine ply backing panels 3) Shutters made out of 19 mm thick ply finish with material & 6 mm thick teakwood leaping with egde moulding of approved profile if any shall be provided in all exposed ply edge surfaces & be finished with melamine polish. 4) hardwares such as heavy duty hinges, brass body locks (Elpro make) with extra large group key of approved quality, magnetic ball catchers, handles, towerbolt etc. All exposed woodwork to be finished with 3 coats of melamine polish & all internal surface finished with 3 coats of french polish. The exposed surfaces shall be finished with 1.5 mm thk. laminate of approved shade & colour. All as per detailed drgs and instructions of EIC / Architect. 79 Sub Estimate No. 5 -Doors & Windows Works 80 Providing and fixing in position (as per 1868/1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer incharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box. 81 Providing and fixing best quality superior Indian teak wood frame for doors, windows and ventilators including all moulding, rebating, jointing, hold fasts of MS flats of minimum size 20 x 3 mm, having length of 225 mm for doors & 150 mm for windows and finishing with 3 coats of French polish or one coat of primer and synthetic enamel paint in two coats as directed etc. complete. 82 Providing & fixing 35mm thk. Phenol bonded Flush door finish with one side 1.5 mm thk. Laminate and one side 3 - 4 mm thk Veneer as per approved pattern. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall include all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, latches etc. as required. 83 Providing and fixing trap door made of aluminumpowder coated inner/outer frames/corner fittings finished with gypsum board liner,sealing strips between inner and outer frames including concealed hinges, snap touch latch etc., complete. with 50x50mm alu.frame work support from ceiling to the trap door .The entire item is to be completed in totality as per manufactures specifications and directions of the EIC/Architect. 84 Providing & fixing 35mm thk. Phenol bonded Flush door finish with 3 - 4 mm thk. Veneer on both sides as per approved pattern. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall include all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, latches etc. as required. 85 Providing & fixing door in position Partly Glazed Partly Solid door made up Phenol bonded of 35 mm thk approved flush door of approved size & 12 mm toughened glass approved beading, grooves, approved moulding including necessary hardware, approved adhesive, fitting & fixture Handel, Lock, Floor Spring etc. melamine polish to all exposed surfaces etc complete as per detail drawing as specified & as directed by Engineer-incharge. 86 Providing & fixing 35mm thk. Phenol bonded Flush door finish with 1 mm thk. Laminate on both sides as per approved designs. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall include all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, Panic door Handel, latches etc. as required. 87 Sub Estimate No. 6 -False Ceiling 88 Providing & fixing in position Gypsum Board False Ceiling as per manufacturers specifications & instructions with 12.5mm thick Gypboard Screw-fixed to the underside of suspended G.I. grid. G.I. grid should be constructed & suspended from the main ceiling as per manufacturers instructions & specifications.G.I.grid should consist of ceiling sections at maximum centre to centre distance 450mm, Perimeter channel intermediate channels at maximum centre to centre distance 1200mm. The ceiling sections should be fixed to intermediate channels with connecting clips. G.I.grid should be fixed to R.C.C. slab above with the help of 25mm x 0.5mm strap hanger & soffit cleat. The joints between soffit cleat & strap hanger and G.I.grid & strap hanger should be with 6.4 x 12.7 mm nut & bolt. Soffit cleats should be fixed to R.C.C.ceiling with W.E. type 12mm dia, 17/16 long steel Rawl plug maximum center to center distance (both ways) of strap hangers should be 1200mm. The Gypboard should be fixed to G.I.grid with 25mm long Drawall screws. 89 Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Optra (Microlook) EDGE TILES WITH ARMSTRONG 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 66% GW & 74% RW%. The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2.Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 & passed through 500 hrs of Salt test. The Tile & Grid system used together should carry a 15 year warranty. (Contractor should submit a performance certificate from Armstrong /Ecophone). 90 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 91 Providing and fixing Wooden rafter at ceiling at all height including providing and fixing of aluminium frame work and rafter made up of ply using9/12/19 mm with complete hardware fitting etc complete as per direction of Engineer - in - charge 92 Providing and fixing Wooden ceiling at all height including providing and fixing of aluminium frame work and rafter made up of ply using9/12/19 mm with complete hardware fitting etc complete as per direction of Engineer - in - charge 93 Sub Estimate No. 7 -Loose Furniture 94 Providingandfixinginposition Meeting Room Table of approved shapeshownindrawing.Tabletop made out of 19 X 19 mm & 50 X 38 mm T.W. frame work with both side 6mm thk marine plywood in two layers finished with approved veneer. Apron made out of 50 X 50 mm T.W. frame work with both side 9 mm thk marine plywood finished with approved Veneer. Edge of Table finished with 50 X 50 mm T.W. mouldingwithmelaminepolish. Footrest&skirtingmadeoutof19 mm thk marine plywood finished with approvedVeneer.Edgeoffootrest finished with 25 mm thk wooden half roundmouldingwithmelamine polish.50x50mmwooden connectingmembers.Rateincluding cost of wooden beadings, mouldings, inlays,etc.Topshouldbefinished with approved Veneer. Sides finished withapprovedveneer&melamine polish.completeasperdetail drawing, as specified and as directed by Architect. 95 Providing & arranging in position ExecutiveCabinTableFinishedwith Veneer in table size 2500 mm x 1200 mm x 750 mm) side table (size 1100 mm x 450 mm x 700 mm) desk units in19mmthk.Marineplywood includingsideunit,drawerunit,tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mminfront&12mmthkinrear& sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawer unit fronts&sidestobefinishedasper drawings.Thefrontmodestypanel etc shall be finished as per drawings &instructionsoftheEIC/Consultant all complete. All trays in writing desks,sideunitstohaveconcealed stoppers.Allpenciltraysshallhave smallcompartmentsforkeeping miscellaneous stationaries. All beadings,mouldings&exposed woodworktobeinteakwood.Foot restshallbemadeoutof19mm plywood frame work with 6 mm top andshallbefinishedwithmatching veneer all molding shall be finish in 3 coatsofmelaminepolish.Allthe tables shall have keyboard drawers to accommodatekeyboardsandmouse wherevernecessaryasperdrawing. Rateincludeofallhardware,like hinges, drawer channel, handles, lock, moulding, lipping patti etc. drawingsandalsoshallincludeCPU unit as shown in the drawings approvedbyEIC.Noseperate payment shall be made for this. Tablesallexposedsurfacefinished with a approved veneer in approved pattern as per drawings. All exposed surfaceofsideunittobefinished with a approved veneer. Providing & fixing in position side unit made out of 19 mm thk. Marine ply, with shelves, drawers, shutters etc. as per drawings, finished with approved veneer from outside & laminate from inside.Itemtobecompletedinall respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters,asperthedrawingand details. All shelves, openable shutters,drawerbox,drawerfront etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shallbein6mmthk.Plywood.All exposed surfaces to be finished With veneer of approved shade and make. Allcompletewithnecessary hardware,likekeyboard,CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. 96 Providing&arranginginpositionJt. ExecutiveCabinTableFinishedwith Laminateintablesize2500mmx 1200 mm x 750 mm) side table (size 1100 mm x 450 mm x 700 mm) desk unitsin19mmthk.Marineplywood includingsideunit,drawerunit,tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mminfront&12mmthkinrear& sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawer unit fronts&sidestobefinishedasper drawings.Thefrontmodestypanel etc shall be finished as per drawings &instructionsoftheEIC/Consultant all complete. All trays in writing desks,sideunitstohaveconcealed stoppers.Allpenciltraysshallhave smallcompartmentsforkeeping miscellaneous stationaries. All beadings,mouldings&exposed woodworktobeinteakwood.Foot restshallbemadeoutof19mm plywood frame work with 6 mm top andshallbefinishedwithmatching laminateandallmoldingshallbe finish in 3 coats of melamine polish. Allthetablesshallhavekeyboard drawerstoaccommodatekeyboards andmousewherevernecessaryas per drawing. Rate include of all hardware, like hinges, drawer channel, handles, lock, moulding, lippingpattietc.drawingsandalso shall include CPU unit as shown in the drawingsapprovedbyEIC.No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposedsurfaceofsideunittobe finishedwithaapprovedlaminate. Providing & fixing in position side unit made out of 19 mm thk. Marine ply, withshelves,drawers,shuttersetc. asperdrawings,finishedwith approvedlaminatefromoutside& inside.Itemtobecompletedinall respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters,asperthedrawingand details. All shelves, openable shutters,drawerbox,drawerfront etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shallbein6mmthk.Plywood.All exposed surfaces to be finished With laminate of approved shade and make.Allcompletewithnecessary hardware,likekeyboard,CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. 97 Providing & arranging in position PA Cabin Table Finished with Laminate in table size 1300 mm x 600 mm x 750 mm) side table (size 900 mm x 450 mm x 700 mm) desk units in 19mm thk.Marineplywoodincludingside unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawerunitfronts&sidestobe finishedasperdrawings.Thefront modesty panel etc shall be finished as perdrawings&instructionsofthe EIC/Consultant all complete. All trays inwritingdesks,sideunitstohave concealedstoppers.Allpenciltrays shallhavesmallcompartmentsfor keeping miscellaneous stationaries. Allbeadings,mouldings&exposed woodworktobeinteakwood.Foot restshallbemadeoutof19mm plywood frame work with 6 mm top andshallbefinishedwithmatching laminateandallmoldingshallbe finish in 3 coats of melamine polish. Allthetablesshallhavekeyboard drawerstoaccommodatekeyboards andmousewherevernecessaryas per drawing. Rate include of all hardware, like hinges, drawer channel, handles, lock, moulding, lippingpattietc.drawingsandalso shall include CPU unit as shown in the drawingsapprovedbyEIC.No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposedsurfaceofsideunittobe finishedwithaapprovedlaminate. Providing & fixing in position side unit made out of 19 mm thk. Marine ply, withshelves,drawers,shuttersetc. asperdrawings,finishedwith approvedlaminatefromoutside& inside.Itemtobecompletedinall respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters,asperthedrawingand details. All shelves, openable shutters,drawerbox,drawerfront etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shallbein6mmthk.Plywood.All exposed surfaces to be finished With laminate of approved shade and make.Allcompletewithnecessary hardware,likekeyboard,CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. 98 Providing and placing in position ReceptionTableofrequiredshape andsize,vertical,topandbottom made of 19mm thk BWP marine grade plywood finished with approval Veneer on both side,the edge of top finished12x30MMthickmatching wood beading,the top finished in PU above 18mm thick glass top. The Reception table verticle,flap,Foot restarein19mmthkBWPmarine grade plywood finished with Approval Veneer internal side and external above6mmthicktoughfnedcolor back painted glass the edge of finished 12 x30 MM thick veneer matching beading. provision Flap shutter shall be provided for Services, electrical, cabling cutouts as per the drawing. All the exposed wood work are to be finished with three or more coatsmelaminepolish.Theentire item is to be completed in totality as per the drawing and directions of the EIC/Architect. 99 Providing & arranging in position Printer Table Finished with Laminate in table size 2000 mm x 600 mm x 750mm)deskunitsin19mmthk. Marineplywoodincludingsideunit, drawerunit,teatray,penciltray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawerunitfronts&sidestobe finishedasperdrawings.Thefront modesty panel etc shall be finished as perdrawings&instructionsofthe EIC/Consultant all complete. All trays inwritingdesks,sideunitstohave concealedstoppers.Allpenciltrays shallhavesmallcompartmentsfor keeping miscellaneous stationaries. Allbeadings,mouldings&exposed woodworktobeinteakwood.Foot restshallbemadeoutof19mm plywood frame work with 6 mm top andshallbefinishedwithmatching laminateandallmoldingshallbe finish in 3 coats of melamine polish. Allthetablesshallhavekeyboard drawerstoaccommodatekeyboards andmousewherevernecessaryas per drawing. Rate include of all hardware, like hinges, drawer channel, handles, lock, moulding, lippingpattietc.drawingsandalso shall include CPU unit as shown in the drawingsapprovedbyEIC.No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposedsurfaceofsideunittobe finished with a approved laminate. 100 Providing & arranging in position Cabin Table Finished with Laminate in table size 1500 mm x 750 mm x 750 mm) side table (size 1100 mm x 450 mm x 700 mm) desk units in 19mm thk.Marineplywoodincludingside unit, drawer unit, tea tray, pencil tray, pullout tray, footrest. All drawers to be in plywood with 19 mm in front & 12mm thk in rear & sides and bottom in 6 mm thk. Plywood Internal surfaces to be laminate. Table tops, drawerunitfronts&sidestobe finishedasperdrawings.Thefront modesty panel etc shall be finished as perdrawings&instructionsofthe EIC/Consultant all complete. All trays inwritingdesks,sideunitstohave concealedstoppers.Allpenciltrays shallhavesmallcompartmentsfor keeping miscellaneous stationaries. Allbeadings,mouldings&exposed woodworktobeinteakwood.Foot restshallbemadeoutof19mm plywood frame work with 6 mm top andshallbefinishedwithmatching laminateandallmoldingshallbe finish in 3 coats of melamine polish. Allthetablesshallhavekeyboard drawerstoaccommodatekeyboards andmousewherevernecessaryas per drawing. Rate include of all hardware, like hinges, drawer channel, handles, lock, moulding, lippingpattietc.drawingsandalso shall include CPU unit as shown in the drawingsapprovedbyEIC.No seperate payment shall be made for this. Tables all exposed surface finished with a approved laminate in approved pattern as per drawings. All exposedsurfaceofsideunittobe finishedwithaapprovedlaminate. Providing & fixing in position side unit made out of 19 mm thk. Marine ply, withshelves,drawers,shuttersetc. asperdrawings,finishedwith approvedlaminatefromoutside& inside.Itemtobecompletedinall respects as per drawing & instructions from EIC. The item shall include a set of drawer and openable shutters,asperthedrawingand details. All shelves, openable shutters,drawerbox,drawerfront etc. shall be made out of 19 mm thick plywood. Drawer sides shall be in 12 mm thk Plywood. Drawer bottom shallbein6mmthk.Plywood.All exposed surfaces to be finished With laminate of approved shade and make.Allcompletewithnecessary hardware,likekeyboard,CPU,Trolly, cable manger etc complected as per drawing & approval of Engineer - In - charge. 101 Modularworkstationsconsistoflow ht. partition screen, work tops, Pedastalunit,filingstoarges(onlyin fewcases),keyboardtray&CPU trolleyasperspecifications mentionedbelow.Theprofilesofthe Aluminium partition frame should be as per the Work top - 25 mm hk. Pre laminated particle board cut to size & shapeasperdesign&drawings. Edges to be fixed with 2mm thk PVC edgebindingofapprovedmake& matching to laminate Key board tray &CPUTrolley-Eachworkstation shallhavePVCmouldedkeyboard tray&M.S.powdercoatedCPU Trolleywithcastors.Pedastalunit- 3 drawer pedastal unit of overall size 450 deep X 450 wide X 725 ht made outof18/16mmprelaminated boardforcaracus&12mm prelaminated board for drawers. Top drawer to be on roller slides and two lowerdrawerstobeof3extens Partition screen: 60mm thick to have one cable channel along main spine, MFC (Melamine Finish Chipboard) on both side upto table top ,each workstation with one tackable board andwhiteboard.Screeninfrontof the table to have frosted glass panel above 102 Modularworkstationsconsistoflow ht. partition screen, work tops, Pedastalunit,filingstoarges(onlyin fewcases),keyboardtray&CPU trolleyasperspecifications mentionedbelow.Theprofilesofthe Aluminium partition frame should be as per the Work top - 25 mm hk. Pre laminated particle board cut to size & shapeasperdesign&drawings. Edges to be fixed with 2mm thk PVC edgebindingofapprovedmake& matching to laminate Key board tray &CPUTrolley-Eachworkstation shallhavePVCmouldedkeyboard tray&M.S.powdercoatedCPU Trolleywithcastors.Pedastalunit- 3 drawer pedastal unit of overall size 450 deep X 450 wide X 725 ht made outof18/16mmprelaminated boardforcaracus&12mm prelaminated board for drawers. Top drawer to be on roller slides and two lowerdrawerstobeof3extens Partition screen: 60mm thick to have one cable channel along main spine, MFC (Melamine Finish Chipboard) on both side upto table top ,each workstation with one tackable board andwhiteboard.Screeninfrontof the table to have frosted glass panel above 103 Tea Table 900mm X 750mm X 450mm for m.s. ante chamber ProvidingAndFixingOfTeaTable 900mmX750mmX450mmWith 12mm Thick Colour Eitched Tempered GlassWithBevelledDrawingMade OutOf18mmThickWaterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. 104 Sub Estimate No. 5 - Chairs And Sofa Works 105 Providing & Arrangemnt of High Back,SynchronizedMechanismwith Multiple Locking, Adjustable Armrest, GasliftforSeatheightadjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 106 Providing & arrangemnt of High back chair - tilt mechanism with multilocking, high density cushion on seatcompositeleatherwithmetallic silver finish base and arms with P.U.castors, Gaslift for height adjustment. 107 Providing & arrangemnt of High back chair - tilt mechanism with multilocking, high density cushion on seatcompositeleatherwithmetallic silver finish base and arms with P.U.castors, Gaslift for height adjustment. 108 Providing & Arrangemnt of MId Back, NormalSyncroMechanism,Fixed Armrest , Gaslift for Seat height adjustment,Standard5-prong/Nylon Base with Leather Upholstery 109 Providing & Arrangemnt of Mid Back, Normal Syncro Mechanism, Fixed Armrest, Gaslift for Seat height adjustment,Standard5-prong/Nylon Base with Leather Upholstery 110 Single Seater Lounge / Sofa in Fabric1. Varnished wooden base, skilfully crafted with finest hardwood for strength & durability. 2. Quality upholstery & fine stitching workmanship. 3. High Density Polyurethane Foam Come With Pocket Spring,toensurealonglasting Shapeofthesofa,providesoftand cushiony seating feeling and provide resilience for greater support and bestseatingcomfortevenforlong seating hours. 111 Providing & supplying multi seater sofas with teakwood internal frame out of size min. 70x40mm as mentioned in drawing with necessary spring /rubberised coir/32 density polyurethene foam/100% latex rubber foam of appropriate quality & thickness as shown in the drawing with melamine polish on all exposed wooden surface. 75mm thk. for seat & 50mm thk for back. 25mm polyurethene in it to give required shape. The rate to include upholstry material of approved velvet(fabric) on outer side & on the inner side white cloth of approved qulaity shade etc. The contractor shall use appropriate size of frame work instead of mentioned to achieve desired shape & comfort as shown. All as per instructions of Engineer-incharge. 112 Single Seater Sofa Fabric finish 113 b) Two Seater Sofa Fabric finish 114 C) Three Seater Sofa Fabric finish 115 Sub Estimate No. 9 - Miscellaneous Works 116 Supplying, Providing & fixing in position of required size pelmets / jamblining made out of 19mm thick marine plywood finished with approved finish mention below and 3 coats of French polish for inside surface as per the direction by Architect. Item to be completed in all respect as per the drawing & instruction from Architect. 117 Veneer Finish. 118 1.5 mm thk Laminate Finish 119 Providing and fixing in position 19mm thk. Marineplywood for soffit finished with below mention including 25 x 25mm thk 2nd class TW wooden frame work (including paint)/ supports & mouldings, groove. Item to be completed in all respects as per drawings & direction by Architect. 120 Laminate Finish 121 Veneer finish 122 Providing and fixing in position 12mm thk soft board panelling with approved adhesive, partition surface including fabric cover, wood beading finished with melamine polish of approved shade etc. complete as per drawings & directions by Architect. 123 Providingandfixinginposition 12mmthksoftboardpanellingwith approvedadhesive,partitionsurface including fabric cover, wood beading finished with melamine polish of approved shade etc. complete as per drawings & directions by Architect. 124 ProvidingandsupplyingArmstrong ‘Optra Acoustical Wall Panelling’ with squareedgesmadeoffibreglass substrate25mmthickandwrapped on the front side with an acoustically transparentandfire-resistantfabric with an option of colours as per the choiceoftheArchitect/Person in-chargeofsize2100x600or 600x600mmprovidingaminimum sound absorption level of 0.90 NRC to beaffixedtowallusingWallpanel impalerssuppliedbyM/sArmstrong IndustriesIndiaPvt.Ltdand construction adhesives as per the instructionslaiddownbythe manufacturer. 125 Providing and Fixing Rollar Blinds AMI Make or approved make & shade of38mmroundAluminiumchannel withBlackoutfabric&teltingwith chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) 126 The fabric shall be Pre-stressed compositematerialofHighTenacity Polyester Yarn with PVC Coating, Aluminium Backing, & Fungistatic Treatment. Fabric shall be of Soltis~B99-alu, Micro-Aerated - coated fabric to provide subtle view and should block thelightflux&offereliminationof glare and sunlight / heat radiance. Composit. Weight: 540 g/m2 (+/-5%) Thickness: 0.47 mm (+/-5%)FabricOpenessFactor:3%Visible Light Transmission: 0%(N-N) Solar Transmission : 0% Solar Reflectance : 25% - 69%Solar Absorption : 28% - 31% Tensile Strength (Warp/Weft): 160/170 daN / 5cmTearingStrength(Warp/Weft): 11/13 daN Fungistatic Treatment: Degree 0, Excellent (EN ISO 846-A) Fire Retardancy:M1/NFP92507, B1-s2,d0/EN 13501-1, CLASS A/ASTME84.ManagementQuality/ Environment – ISO 9001/ ISO 14001 Greenguard Certificate–UL2818 Gold Certification Program for ChemicalEmissionsforBuilding Materials,Finishes&Furnishings Roller Tube shall be of extruded Aluminium alloy 38mm O.D (or as per system dimension) with a minimum wallthicknessof1.0mmduly anodised for long life. Clutch shall be wrap spring design with high strength fibreglassreinforcedpolyster assembly and high carbon steel springs to transmit motion from drivingtodrivenmembersofclutch mechanism.Clutchshalloperateby directionally with the use of an endless beaded chain. Clutch mechanism shall be crash proof, prevent slippage and shall raise and lowersmoothlytoanydesired height.Clutch shall never need adjustment.Idlershallbeofhigh strength fibreglass reinforced polyster,consistingofanoutside sleeve and centre shaft. Sleeve shall provide bearing surface for roller tube androtatefreelyoncentreshaft, providing smooth, quiet and long wearing operation. Brackets shall be of tomised steel powdercoated to give superiorfinish.Bracketshall accommodateoverhead,sideorface mountingwithclutchassemblyon either end of the roller. Bottom of the blind shall be provided with aluminiumtubepowdercoatedina colourmatchingtothefabric.The fabric shall be enclosed in the suitably created pocket along with the tube.Thetubeshallbeclosedfrom sideswithendcapstogiveaneat look. 127 Providing, fixing, applying by CompanyTrainedTechnicians, premium Wall Covering (WallFabric), asperdetailsinattached specifications, or as per detailed specificationsandcoloursattached, or approved equivalent, of approved colour, texture and design, including base and sub-base preparation(on topofexistingP.O.Psurface),all complete, in a neat and workman like manner,asperdirectionsof Engineer-In-Charge. 128 Providing & fixing Artificate like ArtificalPlant,PictureFrameetc.as pershownindrawing& manufacturers specification. Picture Frame / Plant 129 Providingandfixinginposition mouldings out of T.W Moulding complete as per profile given in the detail drawing or as explained out of wooden sections of sizes given below. All should be finished with melamine polish of approved shade & color with minimum 3 coats. This item will operate only for those mouldings which are to be fixed independent of anyotheritemasmentionedinthe BillofQuantitiesandnotmeasured underanyotheritemetc.complete asperdetaildrawing,asspecified and as directed by Architect / Engineer 130 SIZE 15 X 15 MM 131 SIZE 50 X 50 MM 132 SIZE 90 X 12 MM 133 SIZE 25 X 38 MM 134 PolishingwithPUcoatingabovethe veneerwithrequiredcoatsincluding knotting,preparingthesurfaceetc complete as per direction of Engineer - in - charge. 135 Supply&Installationof3MCrystal Glass film Frosted/DUSTED/ effect with approved artwork, cut using digitalplotter.Self-adhesive, bubble-free installation to be done on clean glass , by Authorized Installers only.3M Architectural Markets. 3M interiorWarrantyforaperiodof5 years for interior application. 136 Providing and fixing modular aluminiumanodizedskirtings-1.5 mmthickness(minimum)of approvedprofilesuitablefor partitions,panellingandwalls.The profilesshallbemadefromfinest quality aluminium extrusions and anodizedminimum40micronsfor highdurabilityandcorrosion resistance including all necessary fittingsandaccessoriesfor installationasperthedirectionsof the EIC/Architect. Height 100 MM 137 6mmthkcolouredtoughened lacquered glass (back painted) 138 ProvidingSupplyingandfixining WPC (Wood Plastic Composite) fluted panels are Various colour, Shape and Sizeas per the directions of the EIC/Architect. 139 Providing,aupplying,fabricating and fixingpanel of aluminium composite panel cladding in approved shape madeout of 4mmthickACPsheet material consistingof 3mmthickFR grademineralcorefollowingNBCpart VFireandlifesafety(having2hours fireresistanceinaccordancetoASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminiumsheets(each0.5mmthick of AA 5005/AA3105 grade) The aluminiumcompositepanel cladding sheetshallbecoil coatedwithkynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratioofPVDFandacrylic)coatingof approvedcolourandsg=hadeontop faceandpolymer(service)coatingof bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats, weather silicon sealent,backer rods etc .overall weight of theACPshall not be less than 7.5 Kilogram/Sq.m) 140 Providing & Fixing of 6mm thk Corean Table Top with polishin of Approved make and colour as directed by Engineer in Charge. (Rates excluding GST) 141 Sub Estimate No. 10 - Electrical Works 142 LT Cables (Aluminum) (CB-LT/AL) 143 Supplying, erecting & terminatingFRXLPE insulated, galvanised steelformedwirearmoured (strip) cable,1100 V 3½ core 70 sq. mm. aluminium conductor complete erectedwithglands& lugsonwall/ trusses/pole or laid in provided trench/pipeasperspecification no. CB-LT/AL 144 Supplying, erecting & terminatingFRXLPE insulated, galvanised steelformedwirearmoured (strip) cable,1100 V 3½ core 25 sq. mm. aluminium conductor complete erectedwithglands& lugsonwall/ trusses/pole or laid in provided trench/pipeasperspecification no. CB-LT/AL 145 Bunch of Wires (WG-MA/BW) 146 Supplying & erecting mains with4x16 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/insidepole/busbars or any other places as per specification no.WG-MA/BW 147 LT Cables (Copper) (CB-LT/CU) 148 Supplying, erecting & terminating FRXLPEinsulated,galvanisedsteel formedwirearmoured(strip)cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole orlaidinprovidedtrench/pipeas per specification no. CB-LT/CU 149 Supplying, erecting & terminating FRXLPEinsulated,galvanisedsteel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in providedtrench/pipeasper specification no. CB-LT/CU 150 Supplying, erecting & terminating FRXLPEinsulated,galvanisedsteel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in providedtrench/pipeasper specification no. CB-LT/CU 151 Supplying, erecting & terminating FRXLPEinsulated,galvanisedsteel wire armoured (round) cable 1100 V,3core2.5sq.mm.copper conductor complete erected with glands & lugs, on wall/ trusses/ pole orlaidinprovidedtrench/pipeasper specification no. CB-LT/CU 152 Supplying, erecting & terminating FRXLPEinsulated,galvanisedsteel wire armoured (round) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/pipeasper specification no. CB-LT/CU 153 PANELANDDISTRIBUTIONBOARDs MAINLOWTENSIONPANELGeneral Specification for Power Panels i)The Electricalpanelsshouldbeprocured from Central Power Research Institute(CPRI)approvedPanel manufacturer.ii)Electricalpanels shallbesubjectedtoMeggertests and HV tests at site in the presence of Client/ Consultant as per the requirementofClient/Consultant. iii)TheContractorshouldsubmit3 sets of as built drawings of the Electrical panels. iv)The Electrical panelsfeedersshouldbeproperly labelled using engraved black anodized labels. Also, night glow radiumlabelsshallbeprovidedfor eachfeederspecifyingthenameof the load. v)The detailed specifications missing in the BOQ should be followedfromtheSpecificationsand Electrical Single line diagram in ACAD format.vi)Contractorshouldsubmit thefabricationdrawing,singleline diagram and control logic system to Consultant for approval before fabrication of all panels. vii)The Electricalpanelsmainbody,doors, partitions should be fabricated out of 2mm thick MS steel sheet. vii)Appropriatesizeknockoutholes should be provided in the panels as perthesizeoftheincomingand outgoingcables.Designasper technical specifications and obtain approval of drawings, prior to manufacturing, manufacture, insure, pack with PVC sheets, transport to site, store, erect in proper position, testing and commissioning of Indoor DutyandhavingIP52RatingLT panel cubicle and extendible type front and back operated having Top/Bottom Bus-Bars and Top/bottom Cable/BusDuctentry,&fabricated using14gauge,CRCAsheetsteel for main frame, door and partitions, dust and vermin proof lockable doors and carrying the controlwiringusingapprovedmake FRLS colour coded Wires of minimum 2.5 sq.mm and using approved make pushonterminals.Thepanelshall be floor mounting type, all complete with interconnections by using electrolyticgradetinnedcopperBus Bars of 99.95% purity for Main, submain LT Panels and Cu/ Al busbars forotherpanels,colourcodedheat shrinkablePVCsleeves.ThePanel shall be painted with Powder Coated granularfinishedpaintingwith7 tank painting process with shade No. RAL 7032 from inside and outside all completeasperdrawings,technical specificationsandfinalapprovalof Consultant. 154 Providing & erecting floor/wall mounting,PanelBoard,withdoor, suitableforfourpoleincoming4P MCCB and outgoings up to 63A MCCBs/MCBs on iron frame, as below (Includingallrequiredcomponents, busbar, wiring, metering, cable alley etc.) Incomer : 100A, 4P MCCB 18kA Thermal Magnetic Trip Unit Busbar : 100A,TPNCopperIndicator:LED typeRYBphaseindicatorsMulti FunctionMetertoreadVAHzKW KWh PF and with suitable set of CTs, 2AconnectorwithFuseOutgoings: 40A, 4P MCB 10kA x 2Nos. 32A, 4P MCB10kAx5Nos.32A,2PMCB10kA x 3Nos. Capacitor Bank of total25 KVAR capacity in steps as (5*4 + 3+2KVAr)toworkinautomode (APFC),completewithallnecessary accessories to maintain power factor near unity. 155 LT - MCBDBs (SW-MCBDB) 156 Supplying&erectingtriplepoleand neutraldistributionboard(TPNDB), SPMCBof4ways/phase(12poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. 157 Supplying&erectingtriplepoleand neutraldistributionboard(TPNDB), SPMCBof8ways/phase(24poles), withdoor,1.2mmthickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. 158 Supplyinganderectingsinglepole and neutral distribution board (SPNDB),with2waysforincoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame as per specification no. SW-MCBDB 159 LT - MCBs/ MCB Change Over Switch (SW-MCB) 160 Supplying, erecting & marking FP MCB6Ato32A,withratedshort- circuit breaking capacity (Icn) 10kA in provideddistributionboardasper specification no. SW-MCB 161 Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuitbreakingcapacity(Icn)10kA in provided distribution board as per specification no. SW-MCB 162 Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kAinprovideddistributionboard as per specification no. SW-MCB 163 Supplying,erecting&markingDP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kAinprovideddistributionboard as per specification no. SW-MCB 164 RCCB / RCBO (SW-RCCB/RCBO) 165 Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. 166 Supplying, erecting & commissioning 2poleRCCB40A,electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. 167 Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thicknesssuitableforDPMCB/TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 168 Supplying,fixingandcommissioning 4 pole RCBO 32/40A, with overcurrent,ratedshort-circuit breaking capacity (10 kA) and earth leakageprotection,with30/100/300 mAsensitivityandshortcircuitand earthleakagetripindicationasper specification no SW-RCCB/RCBO 169 Supplying&erectingfourpoleON LOAD change over switch, 415V, 100A, open execution having staggered termination, phase barrier, shroudterminationandterminal coveralongwithauxiliarycontacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3Part-1/3.(ProvisionforDG Change over) 170 Point wiring for light/bell in min. 20 mmFRLSgradeHMSConduitwith1.5 sq.mm (2+1E) FRLSH grade copperwires,modulartypeswitch, earthing and required accessories as per specification No: WG-PW/SW. (Avg. length 6 mtr. from Switch Board) 171 Point wiring for light/bell in min. 20 mm FRLS grade HMS PVCconduit with1.5 sq.mm (2+1E) FRLSH grade copperwires,modulartypeswitch, earthing and required accessories as per specification No: WG-PW/SW.(Avg. length 8 to 10 mtr. from Switch Board) 172 Point Wiring (WG-PW) 173 Secondary point wiring for additional light/bellpointinmin20mmPVC conduit with 1.5 sq.mm (2+1E) FRLSHgradecopperwirewith requiredaccessoriesasper specification no.WG-PW/SW 174 Point wiring for ceiling fan concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copperwires,modulartypeswitch, earthing and required accessories as per specification no.WG-PW/CW 175 Point wiring for light/bell/exhaust fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copperwire,modulartypeswitch, earthing and required accessories as per specification no.WG-PW/SW 176 Pointwiringforindependentplugin minimum20mmHMSPVCconduit with1.5sq.mm(2+1E)FRLSH grade copper wire, modular type switch, earthing and required accessoriesasperspecificationno. WG-PW/SW 177 Concealing ofConduits (WG-MA/CC) 178 Supplying&erectingHMSPVC conduit20mmdia.withnecessary accessories in wall/floor with chiselling appropriately as per specification no.WG-MA/CC. 179 Supplying & laying HMS PVC conduit 20mm dia. with necessary accessories in RCC work/false ceiling/falseflooringasper specification no.WG-MA/CC. 180 Supplying & erecting HMS PVC conduit25mmdia.withnecessary accessories in wall/floor with chiselling appropriately as per specification no.WG-MA/CC. 181 Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 182 Supplying&erectingHMSPVC conduit32mmdia.withnecessary accessories in wall/floor with chiselling appropriately as per specification no.WG-MA/CC. 183 Supplying & laying HMS PVC conduit 32mm dia. with necessary accessories in RCC work/false ceiling/falseflooringasper specification no.WG-MA/CC. 184 Supplying & erecting rigid steel conduit16SWG20mmdia.with necessary accessories in wall/floor withchisellingappropriatelyasper specification no. WG-MA/CC. 185 Supplying & laying rigid steel conduit16SWG20mmdia.withnecessary accessories in RCC work/false ceiling/falseflooringasper specification no.WG-MA/CC. 186 Supplying & erecting rigid steel conduit16SWG25mmdia.with necessary accessories in wall/floor withchisellingappropriatelyasper specification no.WG-MA/CC. 187 Supplying & laying rigid steel conduit 16SWG25mmdia.withnecessary accessories in RCC work/false ceiling/falseflooringasper specification no.WG-MA/CC. 188 Supplyinganderectingmainswith 2x1.5 sq.mm FRLSH copper PVC insulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars oranyotherplacesasper specification No: WG-MA/BW 189 Supplyinganderectingmainswith 2x2.5 sq.mm FRLSH copper PVC insulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars oranyotherplacesasper specification No: WG-MA/BW 190 Supplyinganderectingmainswith 1x2.5 sq.mm FRLSH copper PVC insulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars oranyotherplacesasper specification No: WG-MA/BW 191 Supplyinganderectingmainswith 2x4sq.mmFRLSHcopperPVC insulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars oranyotherplacesasper specification No: WG-MA/BW 192 Supplyinganderectingmainswith 3x2.5sq.mmFRLSHcopper PVCinsulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars oranyotherplacesasper specification No: WG-MA/BW 193 Supplyinganderectingmainswith 3x4sq.mmFRLSHcopperPVC insulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars oranyotherplacesasper specification No: WG-MA/BW 194 Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no.x0.25mmdia.)3coreflexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 195 ELV Cabling (WG-ELVC) 196 Supplying and installing FR PVC sheathedHDPEinsulatedcopper cat-6cablesuitablefornetworking compliantwithANSI/TIA-568.2-D standards in provided conduit/ casing-n-capping as per specification no. WG-ELVC/NC 197 Supplying and installing FR PVC sheathedHDPEinsulatedcopper cat-6Acablesuitablefornetworking compliantwithANSI/TIA-568.2-D standards in provided conduit/ casing-n-capping as per specification no. WG-ELVC/NC 198 Telephone,AudioandVideoWiring (WG-TW/TW) 199 Supplying & erecting 20 pair, 0.5 mm dia.jellyfilledarmouredtelephone coppercablewithpoly-allaminate moisture barrier, polythene sheathed,G.S.Tapearmouredpolythene jacketed having laid in provided trenchasperspecificationno.WG-TW 200 Telephone Accessories (WG-TW/TA) 201 Supplying, erecting & commissioning20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TA 202 Supply & laying RG 6 wire in prelaid surface/ recessed PVC conduits 203 Supply & laying RG 11 wire in prelaid surface/ recessed PVC conduits 204 Modular switches and Accessories 205 Supplyinganderectingmodular type USB Charger socket of 1 module with nominal output voltage of 5V DC±5%andnominaloutputcurrentof 5V, 2-3A, on provided plate and box with wiring connections complete. 206 Supplying and erecting modular pop up Box 8 module with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table . 207 Supplyinganderectingmodular type switch 6A/10A on provided plate and box with wiring connections complete. 208 Supplyinganderectingmodular typeswitch16Aonprovidedplate and box with wiring connections complete. 209 Supplying and erecting modular type3pin6Amultisocketwithsafety shutteronprovidedplateandbox with wiring connections complete. 210 Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutteronprovidedplateandbox with wiring connections complete. 211 Supplying and erecting modular type (two module) electronic step regulatorforfan,onprovidedplate and box with wiring connections complete. 212 Supplying and erecting modular typeT.V. socket single outlet on provided plate and box with wiring connections complete. 213 Supplying and erecting modular type telephone socket one gang with safety shutter on provided plate and boxwithwiringconnections complete. 214 Supplying and erecting modular type computer Jack RJ 45 with safety shutter,onprovidedplateandbox with wiring connections complete. 215 Supplying and erecting modular type bellindicatoronprovidedplateand boxwithwiringconnections complete. 216 Supplying and erecting modular type buzzer220/250Vonprovidedplate and box with wiring connections complete. 217 Supplying and erecting modular type blankingplateonemodule,on provided plate & box. 218 Supplyinganderectingunbreakable concealedtypemodularswitchbox withdoublemountingplatefor1 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 219 Supplyinganderectingunbreakable concealedtypemodularswitchbox withdoublemountingplatefor2 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 220 Supplyinganderectingunbreakable concealedtypemodularswitchbox withdoublemountingplatefor3 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 221 Supplyinganderectingunbreakable concealedtypemodularswitchbox withdoublemountingplatefor4 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 222 Supplyinganderectingunbreakable concealedtypemodularswitchbox withdoublemountingplatefor6 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 223 Supplyinganderectingunbreakable concealedtypemodularswitchbox withdoublemountingplatefor8 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 224 Networking Components (WG- NWC) 225 Supplying, fixing, and configuring 24 ports, PoE switch compliant with IEEE802.3 standards with min. 193W PoE capacity with 4GE SFP uplink in provided rack as per specification no.WG-NWC/ENS 226 Networking Accessories (WG-NAS) 227 Supplying and fixing Cat 6A 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 &ISO/IEC11810completeasper specification no. WG-NAS/PP 228 Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x550x613mm)asper specification no. WG-NAS/RAK 229 Supplying, erecting & terminating 20 m HDMI cord low voltage grade minimum 4k compliant to be laid in providedconduitswithmale/female 19pin HDMI connectors complete. 230 Indoor LED Fittings (FG-IDF/LED) 231 Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhavingsystemlumens outputofMin.1200Lumens,min. efficacyof110lumen/W,CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f.>0.95,operatingrangeof 120-270V, surge protection of 2.5 kV, Lifeclassof50,000HrsatL70B50 including driver, having mounting arrangementwithboardforsurface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 232 Supplying and erecting LED square / circularMax.18Wdownlighter/ PanelLighthavingpressuredie-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K,BeamAngleof120deg., max.rippleof5%,THD<10%,p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of50,000HrsatL70B0including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum2yearswarrantyasperspecification No. FG-IDF/LED. 233 SupplyinganderectingLEDPanel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrenediffuserhavingsystem lumens output of Min 4200 Lumens, min.efficacyof120lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50includingdriver,having mounting arrangement with board for surfacetypeorspringloaded mounting clips complete with minimum2yearswarrantyasperspecification No. FG-IDF/LED. 234 Supplying and erecting decorative pre-wiredboxtypefitting/batten suitable for 4 feet, T8 LED tube light (excluding tube light). 235 Supplyinganderectinganodized aluminium mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K,BeamAngleof110deg., Ripple<5%,THD<20%,p.f.>0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specificationNo. FG-IDF/LED. 236 Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max. 33Wwithhightransitivitydiffuser withsystemlumensoutputofMin. 4000lumens,min.efficacyof120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 , IP20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. 237 Supplying and erecting LED Strip lightMax.45WIP20classhaving minimum lumens output of 800 Lumens/m,min.efficacyof90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%,p.f.>0.95,operatingrangeof 230-270V, Life class of 30,000 Hrs at L70B50includingdriverwith minimum1yearwarrantyasperspecification No. FG-IDF/LED. 238 DMXController5-in-1LEDlighting Control System, Easy to operate, CompatiblewithavarietyofLED drivingIC.Reliablecommunication, support WiFi wireless network transmission and real-time simultaneousdisplay.Alsocanuse internet’sremotecontroltoachieve real-timesimultaneousdisplay. Achieving synchronization/offline seamlessly switch, no need any splitter. 239 DMXloopcontrolcablesuitablefor above controller & dimmable lighting system in suitable size PVC conduit, including all accessories, support etc. 240 Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K,BeamAngleof120deg., max.rippleof5%,THD0.95, operatingrangeof120-270V,surge protectionof2.5kV,Lifeclassof 50,000 Hrs. at L70B50, including driver suitable for Dimming Purpose, havingmountingarrangementwith board for surface type or spring loaded mounting clips complete with 3 years warranty. 241 SupplyinganderectingLEDPanel Light (1200mm X 300mm) Max. 33 W having CRCA powder coated housing, polystyrenediffuserhavingsystem lumens output of Min 4200 Lumens, min.efficacyof120lumen/W, CRI>80, CCT upto 6500K, BeamAngle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50includingdriversuitablefor DimmingPurpose,havingmounting arrangementwithboardforsurface type or spring loaded mounting clips complete with minimum 2 years warranty, similar to specification No. FG-IDF/LED but suitable for Dimming application. 242 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C.50cycles1200mm,Max.Energy Consumptionof28Whavingservice ratio(CMM/W)ofMin.8,PF>0.9, THD<10%withIRremotecontrol, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as perspecification no. FG-FN/CF. 243 OnlineUninterruptiblePowerSupply (UPS)(AP-UPS) 244 Supplying, erecting, testing & commissioning of 10 kVA capacity on line pure sine wave,PWM,IGBT based UPSwith0.9tounityoutputpf,3 phase input & 3 phase output completewithallprotectionsasper specification no. AP-UPS(Without batteries) 245 Supplying, erecting, testing & commissioning of 3 kVA capacity on line pure sine wave,PWM,IGBT based UPSwith0.8tounityoutput pf,singlephaseinput&1phase outputcompletewithallprotections as per specification no. AP-UPS (Without batteries) 246 Batteries for Inverter & UPS 247 Supplyinganderecting12V/100Ah SMFbatterywithbatteryterminal wire, duly charged complete with 24 months warranty complete. 248 Cable Tray (CB-CT) 249 Providing & erecting hot dipped galvanised cover suitable for ladder/perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mmheightcompletewithnecessary hardware. 250 Providing & erecting hot dipped galvanised cover suitable for ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of200mmwidth&20mmheight complete with necessary hardware. 251 Supply&Installationofunderfloor Raceways,rectangularprofile& Junctionbox.Thecostshallinclude Chiselling/floorCuttingasrequired tofixtheu/fRacewayswith supporting and fixing accessories including Joint sleeves, fasteners etc. (Refilling and Making good, finish floor will be in Civil scope) 252 GI Trunking, 75mm (wide) x 38 mm (height), single compartment 253 GI Trunking, 100mm (wide) x 38 mm (height), single compartment 254 GI Junction Box with cover, Adjustable 150mm X 150mm x 65-90mm 255 GI Junction Box with cover, Adjustable 225mm x 225mm x 65-90mm 256 Supplying and erecting PVC box trunkingofsize50x50mm.with accessories on wall/ceiling as per specification No: WG-MA/BOX. 257 Supplying and erecting PVC box trunkingofsize100x50mm.with accessories on wall/ceiling as per specification No: WG-MA/BOX . 258 Intelligent Addressable Fire Alarm System (FF-AFAS) 259 Supplying, installing, testing and commissioning of micro processor based intelligent addressable main firealarmpanel,centralprocessing unitwiththe1loopcapacityand capableofsupportingnotlessthan250devicesanddetectorsperloop, with on-board LCD alphanumeric backlitdisplaysuitableforminimum 80 characters, operating at 230 V 50 Hz - AC with inbuilt Battery Backup of a minimum 24 hours in normal conditionand30minutesinalarm condition, The panel shall have suitable provision for network connectivity&compatibleforthird party integration(Open Protocol to communicate)viaa MODBUS/BACNET interface etc. conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with3yearsreplacementwarrantyand inclusiveoflifetimesoftwarelicense validity, as per specification no FF-AFAS/CP. 260 Supplying, installing, testing and commissioning of Addressable Optical Photo Smoke Detector. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall havesingle/twinbi-colourLEDfor 360degviewing.Thedetectoris conformingtoIS2189:2008, 11360_1985_Reff2020_EN 54 /VdS / UL & FM approved with 3 years equipmentreplacementwarranty,Designed to meet UL268, 7th Edition. FF-AFAS/SD. 261 Supplying, installing, testing and commissioningofintelligent addressable thermal/heat detector with fixed temperature thermistor with 0°C to 88°C temperature range, complete with base as required, single/twinLED’swith360degree view,in-builtlockingmechanismto checktheremovalandpilferageof thedetector,.DetectorShall conformingtoIS:2175-1988 reaffirmed 2000, IS 15908:2021 / EN 54 / VdS / UL & FM approved with 3 years equipment replacement warranty,DesignedtomeetUL268, 7th Edition, , as per specification no FF-AFAS/HD - ROR. 262 Supplying, installing, testing and commissioning of Addressable Multisensor/MulticriteriaPhoto Thermal(Smoke+Heat)Detector. The detector shall have twin bi-colour LED for 360 deg viewing. The intelligent multi criteria detection deviceshallincludetheabilityto combinethesignalofthethermal sensorwiththesignalofthe photoelectricsignalinaneffortto reacthastilyintheeventofafire situation.Itshallalsoincludethe inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristicsofthethermaland smoke sensing chambers and comparingthemtoadatabaseof actual fire and deceptive phenomena. Thisitemisreferredfor Non-conditioning Area conforming to EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty,DesignedtomeetUL268, 7th Edition. 263 Supplying, installing, testing and commissioning of addressable fire control/relay module for AHU, Access Control,Lifts,Staircase Pressurization, Fire Suppression & otherThirdPartyOutputsetc., Module shall conforming to IS 5051 Part2(Sec1to3):1982reed relays / EN 54/VdS / UL & FM approved with3yearsequipment replacement warranty, as per specification no FF-AFAS/CRM-FCM 264 Supplying, installing, testing and commissioning of addressable fire monitormoduleforflowswitches, Panic Bars & other Third Party Inputs. Themonitormoduleshallmonitor potentialfreecontacts.Thedevice shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982Reedrelays,EN54/VdS/UL&FM approved with3yearsequipmentreplacement warranty, as per specification no FF-AFAS/MM 265 Supplying, installing, testing and commissioning of addressable fire isolatormoduleforisolatingshort/ dewired / loose circuits with automaticresettingarrangement. IsolatorBasecanalsobeproposed, howeverinthatcaseneedstobe considered with each detector & module. The device shall have an LED whichshallblinkinnormalstate& getsteadyonactivationtomonitor the health status of the device. module complete as required. ModuleshallconformingtoIS5051 Part2(Sec1to3):1982,,EN 54/VdS/UL&FMapprovedwith3 years equipment replacement warranty, FF-AFAS/ISM 266 Supplying, installing, testing and commissioning of addressable manual callpoints(breakglasstype/pull stationtype),madeofaddressable breakglassplasticsquareinshape surface/flushmounted withBreak Glassmassageembeddedonthe glass,completeerectedwith mountingbaseandrequired accessories, Module shall conform to EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MCP. 267 Supplying, installing, testing and commissioning of Addressable SoundercumStroberatedat minimum75dB@3mforAudible annunciation and minimum 75cd flashing at 1 Hz for visual indication. Module shall conforming to IS 2189: 2008, IS 15908:2021 / EN 54/VdS /UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/ S-ST 268 ConventionalFireAlarmSystem (FF-FAS) 269 Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28VdcsupplyhavingFRPolymer ABSHousingcompleteasper specification no. FF-FAAS/RRI 270 Supplying, installing, testing and commissioningFR,XLPEarmoured cable2core1.5sq.mm.copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU 271 Public Address Systems (PA) 272 Supplying, erecting, testing & commissioning Mixer Amplifier 250W RMS Power with Built-in Digital Player, MP3 Player with USB/ SD/ MMC Card Reader,Bluetoothwithremoteand having min 6 Mic & 2 Aux Inputs with Box Speaker/DriverUnitselectorswitch. Frequencyresponse50-15,000Hz ±3dB. The unit shall have Preamplifier and Line Output for connecting to a Booster Amplifierandforrecordingthe programme with Resettable circuit breaker for protection against overload and short circuit.Theunitshallhavespeaker output range of 4?, 8?/(Low Impedence) and 70V&100V/(HighImpedence)&It can instanttransfertoDCpowerifAC power fails. Signal to noise ratio between60dB to 65dB complete as per specification no. PA-MA 273 Supplying, installing, testing & commissioning 2-Way flush mount Ceiling Speakers with input power 20W RMS power, with power taps on 20/10/5W, 100V & 70V line, frequency response 90-18000Hz, stylish metal mesh grill and plastic frame, operates on 100V line for excellent reproduction of both speech and music, wide frequency response andadjustabletweetercompleteas per specification no. PA-FMCS 274 Supplying,erecting,testingand commissioning of multistrand annealed bare copperconductor,transparentPVC insulated2Cx1.5sqmmspeaker wire in provided trunking/conduit etc.complete as per specification no. PA-TSPWR 275 Supplying, Installing, testing and commissioningofSupercardioid professional WiredDynamicmicrophonewith noiselessmagneticreadswitch, frequency Response : 50-18,000Hz, Sensitivity : 2.5mV/Pa,Impedance:300?,with quick detachableholderwith3-pin professionalXLRconnector&10m twin core shielded low noise cable onprovided stand complete as per specification no. PA-WDM 276 Supplying & erecting Microphone table/floor stand with height 350-530 mm, base dia. min 150 mm, min. weight 1.8 kg with superior quality of chrome plating/powdercoating(resistantto rust & corrosion) having sturdy mechanism forensuringtroublefreemovement and positioning ofmicrophone complete as per specification no. PA-MTS 277 Supplying,erecting,Volumecontrol withfaceplatandconcealedmetal box for PA speaker. 278 CCTVSystems(CCTV)Cameras (CCTV-CAM) 279 Supplying&erectingofHigh definition2MegapixelIPIRBullet Camera with following features : Image Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 1920 x 1080Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 30m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4mm,horizontalFOV86°,vertical FOV 47°, diagonal FOV 102°6mm,horizontalFOV55°,vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0Lux(IR)NightVisionDistance minimum IR - 30m. Camera minimum Adjustment Angles -Pan:350°,Tilt:72°,Rotate: 350°.PowerSupply:Support12VDC& PoE, IP67, IK10 - Vandal Resistant.BuiltinmicroSD/SDHC/SDXCcard slot of minimum 128 GB,Built in microphone. minimum Input/Output - Audio in × 1,AudioOut×1,Alarmin×1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. ImageEnhancements : Day/Night-Auto(ICR)/Color/Black& White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation,Highlight Compensation. Events : Privacy Masking, Motion detection,Scenechangedetection, Facecapture,Videotampering,audio exception detection, Region entrance detection, Region exiting detection. Operatingtemperature(-30to60° C ) .Security- User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log,TLS1.2,AES-256,SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS,TCP/IP,SecureReal-Time Transport Protocol (SRTP), Bonjour, SNMPandSecureshell(SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting heightnotmorethan5meter)etc withallaccessoriesetccompleteas per specification no.CCTV-CAM. 280 Supplying&erectingofHigh definition 2 Megapixel IP IR varifocal Bullet Camera with following features, Image Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 1920 x 1080Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutionsWDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, LensType:2.8-13mmLens, auto/motorized varifocal focal, Field of View :horizontal FOV 103° to 32°, vertical FOV 73° to 24°, diagonal FOV 142° to 40° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0Lux(IR)NightVisionDistance Min IR- 50m, Camera minimum Adj ustment Angles -Pan:350°,Tilt:72°,Rotate: 350°. PowerSupply:Support12VDC& PoE,IP67, IK10 – Vandal Resistant. BuiltinmicroSD/SDHC/SDXCcard slot of min 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance.ImageEnhancements:Day/Night- Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic WhiteBalance,AutomaticGain Control, BacklightCompensation,Highlight Compensation.Events : Privacy Masking, Motion detection,Scenechangedetection,Face capture,Videotampering,audio exception detection, Region entrance detection, Region exiting detection. Operatingtemperature(-30to60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS,TCP/IP,SecureReal-Time Transport Protocol (SRTP), Bonjour, SNMPandSecureshell(SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACHcompliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting heightnotmorethan5meter)etc withallaccessoriesetccompleteas per specification no. CCTV-CAM. 281 Supplying, installing, testing & commissioningof8/10Ch.Network Video Recorder(NVR),suitablefor2MP cameras only with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920x1080. Support H.265 or higher, H.264, MJPEG,Incoming Bandwidth 80Mbps with minimum 2 SATA Hard Disks,ANR Technology, 2SATAinterfacesfor2HDDsand capacity of each HDD up to 8TB, minimum02USBport,AlarmI/O 4/1, RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, supportmultibrandnetwork Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programmingetccompleteasper specifications no. CCTV-NVR 282 Supplying&erecting4TBinternal SurveillanceHDDsuitableforSATA Port of NVR, interface transfer rate 6 GB/S,Maximumsustainedtransfer rate 150MB/Secto180MB/S.Drivebay supported08+,Camerassupported up to 64, Cache (MB) 64, Load/Unload Cycle-3000000,WorkLoadRating per Year 180TB,MTBF1000000Hrs.HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD 283 Supplying & erecting 32 professional LED Monitor with 1920*1080 (Full HD) Display, suitable for 16 channel NVR and following features Brightness: minimum 250 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC, USB, Audio In, Built-in speakers maximum 2 W, Suitable to operate on 100-240 V 50 HzACsupplyand24/7DutyCycle dulyerectedonwallortabletopwith standard accessories like wall mount stand and wiringconnectionsetc.completeas per specifications no. CCTV-MON 284 Supplying and installing FR PVC sheathedHDPEinsulatedcopper cat-6 armoured cable suitable for networking compliant with ANSI/TIA-568.2-Dstandardsasper specification no. WG-ELVC/NC 285 Supplying and erecting 6 fibers LSZH armoured multimode optical fiber cable with, core dia 50/125 µm (OM3),suitableupto10GBPS, complianttoIEC60793/IEC60794 standards,onwall/ceilingorlaidin providedpipe/trenchasper specification no. WG-ELVC/OFC 286 Supplying, fixing, and configuring 8-ports managed gigabit, layer-2 switch, 10/100/1000 base-T, PoE smartswitchplus2SFPerectedin providedrackcompliantwithIEEE 802.3 standards complete. 287 Supplying, Installing, Testing & CommissioningofRodentRepellent system consisting of the following: 288 TransducersAbove/BelowFalse Ceiling (approx coverage area 150sq.ft) 289 TransducersBelowFalseCeiling (approx coverage area 300sq.ft) 290 DigitalTypeMicroprosserbased MasterControllerwithGraphicLCD display for controlling the parameters suchaswavespeed,wavedensity, frequency,Transducertesting.The controller should support upto 20 transducers in dedicated connection & 24transducersinsingleloop @300/150sq.fteach.Thecontroller shall be networkable on RS 485 havingfacilitytosupportHardwired Third Party BMS integration via Modbus. The system shall use UL and CE approved transformers for power supply. 291 Testing,Commissioning& Verification Kit comprising of UltrasoundWave Analyzer (Software and Hardware) that can do the following: a. Capture,Record and Report (in pdf format) One Third Octave Ultrasound BandFrequenciesemittedfromthe transducers thereby ensuring HUMAN SAFETYasperIRPA(International Radiation Protection Association, Geneva) Guidelines. b. Capture,Record and Report (in pdf format) ultrasound output from each transducerdepictingindividual frequencypeaksalongwith corresponding sound pressure levels, current operating band and the Controller Name for verifying the product. 292 Supplying and installing FR PVC sheathedHDPEinsulatedcopper cat-6cablesuitablefornetworking compliantwithANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC 293 Supplying, Installation & commissioning of Sony make 85” 4K LEDTVhavingmodelno. FW-85BZ40H with bracket and proper installation etc. complete, as per directionofengineer-in-charge. (Rates Excluding GST) 294 Supplying, Installation & commissioning of Sony make 65” 4K LEDTVhavingmodelno. FW-65BZ30J with bracket and proper installation etc. complete, as per directionofengineer-in-charge. (Rates Excluding GST) 295 Supplying, Installation & commissioning of Sony make 43” 4K LEDTVhavingmodelno. FW-43BZ30J with bracket and proper installation etc. complete, as per directionofengineer-in-charge. (Rates Excluding GST) 296 Supplyinganderectingmodularpop up Box 8 module with provided AV/HDMI , RJ 45,6 A electrical sockets and switch on provided table 297 Supplying, erecting & terminating 20 m HDMI cord low voltage grade minimum 4k compliant to be laid in providedconduitswithmale/female 19pin HDMI connectors complete 298 Sub Estimate No. 11 - Fire fittings System 299 Pipes (FF-PP) 300 Supplying and erecting G.I. pipe ‘C’ class ERW 20 mm dia with necessary fittings duly painted with two coats of syntheticenamelpaintoffirered colouroveracoatofprimer(ISC code536asperIS2932of2003) complete as per specification no. FF-PP 301 Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings duly painted with two coats of syntheticenamelpaintoffirered colouroveracoatofprimer(ISC code536asperIS2932of2003) complete as per specification no. FF-PP 302 Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings duly painted with two coats of syntheticenamelpaintoffirered colouroveracoatofprimer(ISC code536asperIS2932of2003) complete as per specification no. FF-PP 303 Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings duly painted with two coats of syntheticenamelpaintoffirered colouroveracoatofprimer(ISC code536asperIS2932of2003) complete as per specification no. FF-PP 304 Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings duly painted with two coats of syntheticenamelpaintoffirered colouroveracoatofprimer(ISC code536asperIS2932of2003) complete as per specification no. FF-PP 305 Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings duly painted with two coats of syntheticenamelpaintoffirered colouroveracoatofprimer(ISC code536asperIS2932of2003) complete as per specification no. FF-PP 306 Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessaryfittingsdulypaintedwith twocoatsofsyntheticenamelpaint offireredcolouroveracoatof primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP 307 Supplying and erecting G.I. pipe ‘C’ classERW100mmdiawith necessaryfittingsdulypaintedwith twocoatsofsyntheticenamelpaint offireredcolouroveracoatof primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP 308 Supplying and erecting 100 mm dia. castirondoubleflangesluicevalve complete with PN16 pressure rating, as per specification no. FF-VL/SV 309 Valves (FF-VL) 310 Supplyinganderecting50mmdia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV 311 Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV 312 Supplyinganderecting75/80mm dia cast iron double flange ball type NRVcompletewithPN16pressure rating, as per specification no. FF-VL/NRV 313 Supplying and erecting 100 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV 314 Supplyinganderecting75/80mm diaCastIronendlinestrainerof Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standardOAR(openareaRatio)for positive suction complete as per specification no. FF-VL/ELS 315 Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flangedendpattern,PN16pressure rating,SSscreen,endconnection withFlanged/Screwed/Socket Weld / Butt Weld End etc with standardOAR(openareaRatio)for positive suction complete as per specification no. FF-VL/ELS 316 Supplyinganderecting25mmdia gun metal gate valve complete with PN16pressurerating,asper specification no. FF-VL/GV 317 Supplyinganderecting50mmdia gun metal gate valve complete with PN16pressurerating,asper specification no. FF-VL/GV 318 Sprinklers (FF-SPR) 319 Supplying,erecting,testingand commissioningofUpright/Pendent quartzoid bulb sprinkler, 15 mm (½) dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR./UP 320 Supplying,erecting,testingand commissioningofhorizontalsidewall quartzoid bulb sprinkler,15 mm (½) dia quartzoid bulb. NBCM Body chromefinished,68ºCfixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR/SS 321 Supplying,erecting,testingand commissioning of concealed quartzoid bulb sprinkler, 15 mm (½) dia quartzoidbulb.NBCMBodychrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR/CON 322 Supplyingerecting,testingand commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximumworkingpressureof175 PSI test pressure of 875 PSI (Burst) withbranchline(Inlet)25mmNPT malethreadtosprinklerhead (Outlet)15mmNPTfemalethread with reducer, nipple, 2 side brackets, center bracket, stockbar of 1000 mm size (UL Listed) complete as requiredas per specification no. FF-SPR/FHP 323 Supplyingerecting,testingand commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximumworkingpressureof175 PSI test pressure of 875 PSI (Burst) withbranchline(Inlet)25mmNPT malethreadtosprinklerhead (Outlet)15mmNPTfemalethread with reducer, nipple, 2 side brackets, center bracket, stockbar of 1200 mm size (UL Listed) complete as required as per specification no. FF-SPR/FHP 324 Supplyingerecting,testingand commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximumworkingpressureof175 PSI test pressure of 875 PSI (Burst) withbranchline(Inlet)25mmNPT malethreadtosprinklerhead (Outlet)15mmNPTfemalethread with reducer, nipple, 2 side brackets, center bracket, stockbar of 1500 mm size(ULListed)completeas required as per specification no. FF-SPR/FHP 325 Fire Fighting Accessories (FF-FFA) Priming Tank 326 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kgpercmsquarefittedwith12/15 mm dia. pad cock valve, erected with providedG.I.pipe,elbowetc. complete as per specification no. FF-FFA/PG 327 Supplying and fixing of self expanding,readytouse polyurethane(PU) foam sealant of minimum750mlbottle,suitableto sealtheopeningsofallkindsof cables, pipes and cable support system in steel, aluminium and plasticprofiles(excepthollowcore conductors).Sealantshallhave minimum2hourfirerating, conforming to EN 1366-4:2021 as per specification no FF-FRS. 328 Fire Extinguishers 329 Supplying & erecting Carbon Dioxide (CO2)fireextinguisherof4.5kg. capacity cartridge type conform to IS 2878/15683completeerectedwith necessaryclampmadefrom50x6 mm. M. S. flat with nut & bolts routed in wall complete. 330 Clean Agent Fire Suppression System (FF-FSS) 331 Supplyingerecting,testingand commissioning of Direct Low Pressure (DLP),automaticelectricalcabinet fire suppression system kit comprises of the mild steel cylinder, hydraulic tested to 30kg/cm2tocheckforleakages& burst pressure above 110kg/cm2. duly hot phosphate & epoxy powder coated internally and externally more than65micronsorpaintedwith1 coatofprimerand2coatsofred enamelpaintallcomplete.The Cylinder assembly is filled with 4 kg to 4.54 kgs of clean agent gas (FK-5-1-12 UL listed) and pre-pressurized to 15/16 Bar having storage & operating temperature rangeof(-)17.8deg.Cto54.4deg.C withallimportantaccessoriese.g. brassassemblyvalvewithpressure gauge, end of line plug with pressure gauge suitable to connect with provided Linear heat detection tube, completewithmountingbracket assembly,requiredsizerubber grommets,plasticloopclamps, pressureswitchandcaution& cylinder Labels etc. 332 ABC type fire extinguishers of 6 kg. capacity having IS certification mark shall be provided & spread over each floor 333 Removal of Existing (non suitable piping&sprinklersfornewInterior Plan)Sprinklersystem,completein allresepctsforproposedrenovation area. 334 Sub Estimate No. 12- HVAC Works (High Side & Low Side) 335 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.4TR (512 cfm) to 2.0TR (618 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete.The unit consisting with any additional refrigerant and oil charge as per requirement during installation. (MD -2 & Meeting Room -2) 336 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassetteroom/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.0TR (441 cfm) to 1.3TR(512 to 530 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. (Jt.MD Cabin-2, Waiting area-1) 337 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 Way cassetteroom/indoor unit (IDU-compact/standard size) ofnominal cooling capacity 1.0TR (441 cfm) to 1.3TR (512 cfm) having EER as per BEE standards andspecifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDUwith drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, andfresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, ACsupply complete. The unit consisting with any additional refrigerant and oilcharge as per requirement during installation. (Ante Room, Serverroom) 338 Supply, installation, testing andcommissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 0.6TR (420 cfm) to 0.8TR (441 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.(PA Cabin-1 & Typical Cabins-1) 339 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.0TR (441cfm) to 1.3TR (512 cfm) having EER as per BEE standards and specifications, suitable as per siterequirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastalarea in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oilcharge as per requirement during installation. (Server area) 340 Supply, installation, testing and each commissioning of VRF/VRV based Hi-wall type room/indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be of decorative slim dimension suitable indoor wall mounting. The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installationcomplete. (Printer Area) 341 Supply,installation,testingand commissioning of VRF/VRV based ceiling suspended 2Waycassette room / indoor unit (IDU-compact/standardsize)of nominal cooling capacity 1.4TR (512 cfm) to 1.7TR (618 cfm) having EER as per BEE standards and specifications,suitableaspersite requirementwithswinglouversand adjustablebladesfromsides.IDU with drainage arrangements, fan, refrigerantliquidandrefrigerant piping,cordlessremotecontrol,and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil chargeasperrequirementduring installation. (Reception-1 & Staff Area-5) 342 Supply,installation,testingand commissioning of VRF/VRV based ceiling suspended 4Waycassette room/indoor unit (IDU-compact/standardsize)of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR (1100 cfm) having EER as per BEE standards and specifications,suitableaspersite requirementwithswinglouversand adjustablebladesfromsides.IDU with drainage arrangements, fan, refrigerantliquidandrefrigerant piping,cordlessremotecontrol,and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil chargeasperrequirementduring installation. (Lobby Area-Stilt Floor) 343 Supplying,erecting,testingand commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable greenequivalentrefrigerant,for minimum cooling capacity as delivering100%capacityat47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air dischargesuitableforlongerpiping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRVtechnologymicroprocessor basedcontrol compressor starter/controlpanelwithscroll compressor, air cooled copper condensercoilofsuitableshapefor increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver,coppertubealuminiumfin aircooledcondenser,condenserfan withmotorsuitablefor415V±10%, 50Hz,3phasepowersupply(all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housedinpowdercoatedweather proof cabinet complete. 344 Supplying,erecting,testingand commissioning of 22HP, VRF/VRV air conditioning system outdoor unit (ODU)complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable greenequivalentrefrigerant,for minimumcooling capacity as delivering100%capacityat47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air dischargesuitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technologymicroprocessor based control compressor starter / controlpanelwithscroll compressor, air cooled copper condensercoilofsuitableshapefor increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, coppertubealuminiumfin aircooledcondenser, condenserfan withmotorsuitablefor415V±10%, 50Hz,3phasepowersupply(all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housedinpowdercoatedweather proof cabinet complete. 345 Supplying and installation of high pressuregraderequiredsizecopper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways,Nitrilerubber insulation, painting etc. with brazing andtestingforleakagesconfirming the normal operation of the VRV/VRF air conditioning system. 346 Supplying,laying/fixing,testingand commissioning of appropriate nominal refrigerantcopperpipeof28.6mm dia(OD)forliquidline/suctionline supplyandreturnpipingofsuitable gauge(hardcopperpipeforliquid mainlineandsoftcopperpipefor refrigerant) along with necessary supports,hangers,clamps,vibration isolators and fittings such as bends, tees,valves,gauges,strainerswith insulation of 19mm thick elastomeric nitrile rubber along with application of multicoatingofVRV/VRFpipingfor protection against mechanical damages,fungalgrowth,flame spread,waterpermeanceandultra violet radiations with OEM standards ofVRV/VRFairconditioningsystem complete. 347 Supplying,laying/fixing,testingand commissioning of appropriate nominal refrigerantcopperpipeof15.9mm dia(OD)forliquidline/suctionline supplyandreturnpipingofsuitable gauge(hardcopperpipeforliquid mainlineandsoftcopperpipefor refrigerant) along with necessary supports,hangers,clamps,vibration isolators and fittings such as bends, tees,valves,gauges,strainerswith insulation of 19mm thick elastomeric nitrile rubber along with application of multicoatingofVRV/VRFpipingfor protection against mechanical damages,fungalgrowth,flame spread, water permeance and ultravioletradiationswithOEM standards of VRV/VRF air conditioning system complete. 348 Supplying,laying/fixing,testingand commissioning of appropriate nominal refrigerantcopperpipeof12.7mm dia(OD)forliquidline/suctionline supplyandreturnpipingofsuitable gauge(hardcopperpipeforliquid mainlineandsoftcopperpipefor refrigerant) along with necessary supports,hangers,clamps,vibration isolators and fittings such as bends, tees,valves,gauges,strainerswith insulation of 19mm thick elastomeric nitrile rubber along with application of multicoatingofVRV/VRFpipingfor protection against mechanical damages,fungalgrowth,flame spread, water permeance and ultravioletradiationswithOEM standards of VRV/VRF air conditioning system complete. 349 Supplying,laying/fixing,testingand commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply andreturnpipingofsuitablegauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) alongwithnecessarysupports, hangers,clamps,vibrationisolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoatingofVRV/VRFpipingfor protection against mechanical damages,fungalgrowth,flame spread, water permeance and ultravioletradiationswithOEM standards of VRV/VRF air conditioning system complete. 350 Supplying,laying/fixing,testingand commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line/suction line supply andreturnpipingofsuitablegauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) alongwithnecessarysupports, hangers,clamps,vibrationisolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoatingofVRV/VRFpipingfor protection against mechanical damages,fungalgrowth,flame spread, water permeance and ultravioletradiationswithOEM standards of VRV/VRF air conditioning system complete. 351 Supply, Installation, Testing & Commissioning of Rectangular shape SoundAttenuatorswithhighquality galavlanized sheet of min 22 G includinghighqualityperforated galvanizedsteelsheetsplitters/ baffles with Inorganic, fire resistant, vermin and moisture proof sound absorbent rock wool of 50kg/m³ density, with liner, duct connections to be made with required slip on PVC jointssizeofattenuator600mmx 450 mm x 150 mm 352 Supply & Installation of Factory Pre-cutSMARTPre-InsulatedINDUS PIR Panels complete CFC & HCFC Free 17mm thick with 80 micron Embossed Aluminium foil (Anti microbial, Anti fungal, Anti corrosion and UV Protection coating) on outer sidesandFSKfoilininternalsides withclosecellnotlessthan95% Rigid Cellular foam insulation of thickness (17mm for Internal Ducting) and material shall be Class O as per BS 476 Part 6 & Part 7 with 2 hours fire rating, with Density of 45± 3 kg/m3 and should have Thermal Conductivity0.023W/mK,Water absorptionshallbenotmorethan 0.03% as per EN 13403 standard and panel should be GreenPro , GRIHA & EPD&SGBCcertifed.Theductwork shouldbecapableofhandling pressures upto 2000 Pascals. The joint between the ducts shall be with Polymerslideintypejointbetween the ducts and all other polymer accessories to be of the same manufacturer. Measurement would be done on outer to outer. Supporting of ThreadedRod(6mm)&CChannel/ Wire supporting of reputed make recommended by Manufacturer to be provided.Manufacturertohave experience of more than 10 years of producing the same material in India. (Approved Makes : Asawa Insulation,AURA, P3) 353 For Duct sizes below 1200 mm (Ducting in Rectangular shape, above false ceiling areas) 354 Supply, installation of GI ducting work with necessary mounting supports as per SMACNA Standards 355 22 Gauge 356 20 Gauge 357 Drain piping: Providing and fixing of 25mmDiaHardPVCdrainwater piping with fittings, support and insulated with 6mm thick closed cell elastomericnitrilerubberinsulation complete as per specifications 358 Outdoor Stand Fabrication for OutdoorSplitUnits:Supply, fabrication and erection of Angle/channel/Flat iron stand, hangingarrangementforair conditioningmachinesincludingnut bolts of required size, making holes, fabrication, welding, cutting, etc. and paintingwithonecoatofredoxide paint & two coat of enamel paint as required as per specifications. 359 Bunch of Wires (WG-MA/BW) 360 Supplying and erecting PVC insulated PVCroundsheathedFR2.5sq.mm (50 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 361 VRV/VRF Air conditioning 362 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300cfm capacitywithmaintainingthestatic pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete. 363 Existing wall /Core cut outs and otherassociatedworktoinstallref net piping from IDU to ODU complete is all respects 364 Carryingoutcorecuttingofsize3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specializedcorecuttingmachinein proper manner and finishing the site as original. 365 Supply,installation,testingand commissioningwirelessremote control having colour LCD panel, real time clock, temperature limitation (16 to30°C,functionslikefilterclean reminder timer suitable to communicate with wired controller complete. 366 Sub Estimate No. 13 -Structural strengthening of parking slot slab 367 Chipping of all loose and Spalling of concretetobottomofslab,beams etc.(whereverrequired),cleaningof reinforcement, carrying out thorough sandblasting,applicationof anti-corrosive zinc rich epoxy primer toexposedreinforcementincluding costofmaterial,labour,equipment, tools, scaffolding etc. complete. 368 Providing and applying one pack bondingcoatbetweenconcrete memberslikeRCCslabs,columns, beams,chajjas,pardisetcand cement mortar plaster using Hack Aid Plast of approved make & approved byEngineerincharge.Cleanthe concrete surface thoroughly to remove dust, dirt, grime, deshuttering oils and rub down to a cleansurface.ApplyHackAidPlast ofapprovedmake&approvedby Engineerinchargebysprayonthe entireconcretesurface.Providea leancement-sanddashcoatover the same. Allow the dash coat to set foraround24hours.Further plasteringasperspecificationscan continue. 369 ProvidingRepairingofhoneycombs and minor damages with Polymer ModifiedMorterincluding material,labour complete in all respect. 370 P/fixing of carbon 100 mm x 1.4 mm carbon laminate with adhesive includingofallmanpowerand equipments complete in all respect 371 Providingsandfacedplaster externallyincementmortarusing approvedscreenedsand,inall positions including base coat of 15 mmthickincementmortar1:4 using waterproofing compound at 1Kilogramper cement bag curing the samefornotlessthan2daysand keepingthesurfaceofthebase coatroughtoreceivethesand faced treatment 6 to 8 mm thickin cement mortar 1:4 finishing the surfacebytakingoutgrainsand curing for fourteen days scaffoldingetc.complete. 372 Providing and applying two coats of exterior acraylic emulsion paint confirmingtocorrespondingI.S.of approved manufacture andof approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applyingprimer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 373 Epoxy for joint sealing of tiles 374 Sub Estimate No. 14 - Architectural Consultancy charges 375 Preparing layout, drawings, plans, detail drawings, colour combinations, sample chart preparation etc. All designing work required for the work including the preparation of electrical layout all complete.
Contract Date: Jul 23, 2025 Contract Value : 3.26 Crore
Government Departments No of Bidders 5
Maharashtra View Result →
12.
Defence #7592337 AOC
Tender For Provision Of Central Mi Room At Sigar Mil Stn Under Ge 872 Ews; 1 Total amount of Sch A Part-IBuilding WorksNote :- This schedule is not pre-priced by MES and the rate indicated as Rs. 0.00 under column 6 signifies this fact only. 2 Soil investigation, Design, Fabrication and Construction of CENTRAL OF MI ROOMin RCC Framed Structure as per Arch Drg No. CWE/DIN/15/25 sheet No. 1/3 to 3/3 dated 20.01.2025 AND CWE/DIN/15/25 sheet No. 1/1 dated 20.01.2025 and specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE : Soil investigation will be measured and paid separately.(i) Size – As per Arch drawing(ii) Height – 320 CM(iii) Fdn – To be design as per SBC report with RCC framed construction.(iv) Plinth – Burnt Brick wk in CM 1:6(v) DPC – 40 mm thick PCC 1:2:4 with WPC(vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling.(vii) Seismic Zone – Strengthening measures for Zone V(viii) Roof – 0.50mm thick Pre-painted Galvalume sheet with MS steel frame structure, (ix) Ceiling : False ceiling with powder coated snap grid frame work. (ix) Internal Plaster – Internal 15 mm thick in CM (1:6)(x) Flooring – Coloured vitrified tiles in all room, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10.(xi) Dado/Skirting – Glazed ceramic tails over 10 mm thick cement screed in CM (1:3) up to lintel height.(xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & PVC doors in toilet bathroom(xiii) Joinery Window – Steel Window with Guard bars/grill (TD Drg No CESZ/2015/TD/19 Sheet No 1R/3, 2R/3 & 3R/3)(xiv) Steel Guard – MS Guard bars to window(xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)(xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core.(xvii) Painting – Synthetic enamel paint on steel/wooden surface.(xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer.External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment- As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi)18mm thick granite over CM 1:3 for steps(xxii) Sanatory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2& 2/2 andTD Drg No CESZ/TD-31 Sheet No 1/2& 2/2).(xxiii) Mosquito Proofing – All external Door and window. 3 NOTE: Schedule ‘A’ Part IItoIXare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured. 4 Total amount of Sch ‘A’ Part II (Excavation and Earthworks) 5 Total amount of Sch ‘A’ Part III (Internal Electrification) 6 Total amount of Sch ‘A’ Part IV (Internal Water supply) 7 Total amount of Sch ‘A’ Part V (Path with interlocking paver block) 8 Total amount of Sch ‘A’ Part VI (Sewage Disposal) 9 Total amount of Sch ‘A’ Part VII (Area Drainage) 10 Total amount of Sch ‘A’ Part VIII (External Water Supply) 11 Total amount of Sch ‘A’ Part IX (External Electrification) 12 SCH A PART X(Miscellaneous B/R and E/M works)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 13 M & L for boring 100 mm dia hole in all kind of soil upto maximum depth 10 meter or up to refuse (N=100) whichever meet earlier including collection of undisturbed sample from cohesive soil only conducting standard penitration test at 12 meter and 1.5 meter interval alternatively as per relevant IS code complete all as directed. 14 Conducting necessary lab test on selected soil sample (obtained from item here in before) as per relevent nature moisture content, bulk and dry density sleve and hydrometer analysis, liquid and plastic limit, SP gravity unconfined compressive test (UU) or direct consolidation test etc complete all as relevant IS codes or all as specified and directed. 15 Completion of field work & lab test result and submission of report in Per Job quadruplicate suggesting depth of foundation type of fundation and safe bearing capacity with CD-1 (one) copy complete all as specified and directed. 16 Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 400 Amps for phases andneutral, install on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and painted with two coats of syntheitc enameled paint over a coat of red oxide primer and made out of 3.15mm CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock make Navtal/Harrison and including grouting of panel with necessary PCC work icomplete all as specified.The scope of work includesthe following accessories with ciruit breakers :-Incoming : - (i) MCCB 4 pole 16 kA,415 Volts,3 phase 63 Amps - 01 Nos(ii) Digital Multi function meter showing :- Volt meter 0 to 500 Volts, Amp meter 0 to 200 Amps – 01 Nos (iii) Indicating lamp LED type one set in incoming phases. (iv) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs. (v) Connection from MCCB to Busbar shall be of solid Aluminium conductor. (vi) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable.Outgoing :-(i) MCCB 4 pole 16 kA,415 Volts, 3 phase 40 Amps - 03 Nos (ii) MCB SPN, 240V, 10 KA, 32 Amps - 03 Nos 17 S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primercomplete all as specified and as directed. 18 M&L for GI bracket fabricated out of light grade GI Tubing of 32 mm dia, 1.5 mtr long of one sided Arm type and along with 02 sets of suitable size of clamps and nut & bolts to fix the bracket on steel tubular pole and inclusive of one primer coat, one under coar and one finishing coat of paint (synthetic enamel) complete all as specified and directed. 19 S&F PVC insulated FRLS copper conductor Wire 1.0 Sqmm, 3 Core, multistranded cable for Providing Connection from Street Light Fitting to Overhead Line/ Junction Box complete all as specified and as directed. 20 Supply and installation of Wall mounted split units indoor/outdoor complete with cordless remote control unit and with in built airioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TRcomplete all as specified and direced. 21 S & F Voltage stabilizer for automatic operation, air cooled indoor type& designed for input variation between up to 140 V to 280 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and direced. 22 S & F Voltage stabilizer for automatic operation, air cooled indoor type& designed for input variation between up to 140 V to 280 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and direced.
Contract Date: Jul 12, 2025 Contract Value : 89.98 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 13
Arunachal Pradesh View Result →
13.
Defence #7509404 AOC
Tender For Provision Of Type A Klp At Mathura Cantt; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH & CULVERTas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGEas listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for BOUNDARY WALL, COMPOUND WALL AND CHAIN LINK FENCING etc.as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 11 Lump sum price worked out by the contractor for COOLING APPLIANCES & AC ALLIED WORKS etc.as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 12 Lump sum price worked out by the contractor for DG SET ALLIED WORKS etc.as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 13 Lump sum price worked out by the contractor for BASKET BALL GROUND & VOLLEY BALL GROUND etc.as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 14 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENT & EARTH WORKetc.as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 15 Lump sum price worked out by the contractor for DEMOLITION WORK.as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 16 Sch A Sec-XVI: MISCELLANEOUS ITEMSNotes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XIV (SITE CLEARANCE, SITE DEVELOPMENT & EARTH WORK schedule). 17 Internal Electrification (Sch A Part-III) . 18 M&L for point wiringwith 1.5 sqmm FRLS single core PVC insulated and unsheathed multistranded copper conductorre and incl PVC rigid non metallic concealed conduit of size 20/25 mmbore medium grade, ISI marked to beterminated in pressed steel terminal boxes with 3mm thick bakelite sheet top cover incl 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multisrtanedcopper earthcontinuity conductor for one lightpoint controlled by one, one way switch or one regulator including repairing the surfaces in CM 1:3 and finishingthe distrubed wall surface withexisitng finishes/ treatment,complete, all as specified & directed by Engr-In -Charge. 19 All as per description of serial item No 15.01 here-in-before butfor onefan point controlled by one, one way switch, complete, all as specified & directed. 20 All as per description of serial item No 15.01 here-in-before butfor One three pin 5 Amp socket outlet point controlled by one, one way switch on independent board. 21 All as per description of serial item No 15.01 here-in-before butfor One three pin 5 Amp socket outlet point controlled by one, one way switch on same board. 22 All as per item No 15.01 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board. 23 All as per description of serial item No 15.01 here-in-before butfor One light point controlled by two, 2- way switchs. 24 S&F highly efficient LED bulbs, 9 watts . 25 S&FSheet metal enclosure distribution board VTPN,4 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers properwithpcc works complete all as specified and directed. 26 S&F for air circulator fan 230 volts single phase oscillating 600 mm sweep suitable for wall mounting 27 SEWAGE DISPOSAL (Sch A Part-V) . 28 M&L for construction of RCC septic tank designed to carry sewage and sludge water, excavation in any type of soil,PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffle walls and roof slab including beams etc vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users, complete, all as specified , shown on drg & directed by Engr-In-Charge. 29 M&L for provn of on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 25 users, complete, all as specified and directed by Enge in Charge. 30 M&L for construction of soakage wells,excavation in any type of soil, foundation in PCC 1:3:6 type C2, well wall of Honey combed and solid in M-25 Design Mix concrete, including intercepting chamber, screen chamber brick work in CM (1:4), RCC cover slab in M-25 Design Mix, inter connecting pipes of RCC/DWC complete filled with brick bats, of size 2.4m dia x 4.5m effective depth, complete, all as specified and directed by Enge in Charge. 31 EXTERNAL WATER SUPPLY(SCH A PART-VIII). 32 Supply & laying in trenches, under floor/on floor, under road, connecting, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends confirming to IS-8329/2000 standard length of K-7 specification of size 100mm bore complete all as specified and directed. Note (i) :- Excavation and earth work will be measured and paid separately. (ii) Cost of jointing rubber shall be deemed to be included in quoted rate. 33 Cutting of existing CI/DI water main pipe in position upto size 250 mm bore for insertion of new tees, branches etc complete all as specified & directed. Note:-Cast iron fittings such as tee, bends, collar, reducer etc shall be measured/ paid separately. 34 Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars, tail pieces, caps and plugs up to 250 mm bore confirming to IS: 1538-1993 complete all as specified and directed. 35 M & L for construction of valve chamber with brick masonry built in CM 1:6 of size 600 mm x 600 mm x 900 mm (internal dimensions) with 15cm thick PCC foundation in PCC 1:4:8 type D2 using (40mm graded stone aggregate), 15mm thick plaster in cm 1:6, 3mm thick MS sheet cover including 40 x 40 x 6mm MS angle iron frame fixed in PCC coping, using PCC 1:2:4 type B1 (using 20mm graded stone aggregate) with necessary locking arrangement and painted with two coats of synthetic enamel paint over a coat of red-oxide primer on all exposed steel surfaces including necessary excavation and earth work in any type soil, returning and filling in and ramming and removal of surplus soil up to a distance not exc 50 mtr, complete, all as specified , shown on drg & directed by Engr-In-Charge. 36 EXTERNAL ELECTRIFICATION . (SCH A PART-X) 37 Supply and fixing of 45 W LED street light with lens optics on LEDs, IP66 protected luminaire fixture made from pressure dia cast aluminum housing & heat resistance toughned glass cover with one number of 45 W driver, operating voltage range 130-275 Volt, suitable upto 50 mm mounting pipe as directed by engineer-in-charge. Make: Crompton Greaves,Cat No.LSTP-45-CDL or equivalent in Philips/Wipro/HPL 38 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 280x170x130 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete. 39 S&FLT paneloutdoortype, dust and vermin proof totally enclosed , with sloping canopy (KIOSK TYPE) fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 800 amps capacity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories( LTP) 40 (Incoming):-(a) MCCB 4 pole 500 A, 50 KA -1 No (b) Indicating lamp 3 Nos(c) LED Multifunctional meter (Make: L&T) -01 NoOutgoing(a)MCCB 4 pole 200 Amps 36 KA - 01 Nos (FP2)(b)MCCB 4 pole 100 Amps 36 KA- 03 Nos (FP1, FP3, FP4)(c)MCCB 4 pole 63 Amps 16 KA- 01 Nos (FP5) 41 S&F LT paneloutdoortype, dust and vermin proof totally enclosed , with sloping canopy (KIOSK TYPE)fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 150 amps capacity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories( FP-1) 42 Incoming(a)MCCB 4 pole 100 Amps 36 KA- 01 Nos (b) Indicating lamp 3 Nos(c) LED Multifunctional meter (Make: L&T) -01 NosOutgoing(a)MCCB 4 pole 63 Amps 16 KA - 01 Nos (Adm Building)(b) MCCB 4 pole 25 Amps 16 KA - 01 Nos (Spare)(c)MCB 2 pole 10 Amps 6 KA- 01(Security Light)(d) Auto timer switch 43 S&FLT paneloutdoortype, dust and vermin proof totally enclosed , with sloping canopy (KIOSK TYPE) fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 300 amps capacity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories( FP-2) 44 Incoming(a)MCCB 4 pole 200 Amps 36 KA - 01 Nos (b) Indicating lamp 3 Nos(c) LED Multifunctional meter (Make: L&T) -01 NosOutgoing(a) MCCB 4 pole 25 Amps 16 KA - 01 Nos (High Mast)(b)MCCB 4 pole 63 Amps 16 KA- 03 Nos (Cold room, fresh store, shorting shed)(c)MCB 2 pole 10 Amps 6 KA- 02(Trademan Shop & Security Light)(d) Auto timer switch 45 S&FLT paneloutdoortype, dust and vermin proof totally enclosed , with sloping canopy (KIOSK TYPE) fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 150 amps capacity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories( FP-3) 46 Incoming(a)MCCB 4 pole 100 Amps 36 KA- 01 Nos (b) Indicating lamp 3 Nos(c) LED Multifunctional meter (Make: L&T) -01 NosOutgoing(a) MCCB 4 pole 25 Amps 16 KA - 05 Nos (OR living, OR Mess, Religious Place, Edn Institute, High Mast)(b)MCB 2 pole 10 Amps 6 KA- 03(JCO Living , Baggage Room & Security Light)(c) Auto timer switch 47 S&F LT paneloutdoortype, dust and vermin proof totally enclosed , with sloping canopy (KIOSK TYPE) fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 150 amps capacity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories( FP-4) 48 Incoming(a)MCCB 4 pole 100 Amps 36 KA- 01 Nos (b) Indicating lamp 3 Nos(c) LED Multifunctional meter (Make: L&T) -01 NosOutgoing(a) MCCB 4 pole 25 Amps 16 KA - 02 Nos (MT Storage, High Mast)(b)MCCB 4 pole 40 Amps 16 KA - 01 Nos ( Depot Area)(c)MCB 2 pole 10 Amps 6 KA- 01(Security Light)(d) Auto timer switch 49 S&FLT paneloutdoortype, dust and vermin proof totally enclosed , with sloping canopy fabricated out of steel sections, the door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified suitable for 415 Volts, 50 Hz 3 phase and nuetral system and shall be completed with 100 amps capacity copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable copper lugs comprising of following accessories( FP-5) 50 Incoming(a)MCCB 4 pole 63 Amps 16 KA- 01 Nos (b) Indicating lamp 3 Nos(c) LED Multifunctional meter (Make: L&T) -01 NosOutgoing(a)MCCB 4 pole 40 Amps 16 KA - 01 Nos (Storage Accm)(b) MCCB 4 pole 25 Amps 16 KA - 01 Nos (POL Area)(c)MCB 2 pole 10 Amps 6 KA- 02(Guard House & Security Light)(d) Auto timer switch 51 Supply & lay Rubber mat of 1 meter x 2 meter x 10 mm 52 Supply, installing, testing and commissioning, factory made and tested, automatic power factor control panel 100 KVAR (APFC Panel) out door type, cubical front opening type, The panel shall be of protection class IP-66 and made out of 3.15 mm CRCA MS sheet and MS angle 40x40x6 mm thick frame, power coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of synthetic enamel paint over one coat of red oxide primer, including internal wiring with PVC insulated solid copper conductor cables, IS-694 marked, 1100 volts grade of appropriate size but not less then 2.5 sqmm and comprising of the following and copper bus bar TP 300 Amp rating:- 53 Incoming(a)MCCB, TP,415V, 250 Amp rating, 36 KA rating with Thermal Magnetic release for O/C & S/C protection :01 No(b ) Microprocessor based, modular type, intelligent APFC relay capable of having self adjustment to any capacitor value suitable to maintain power factor between 0.95 to 0.99 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps.(c) Indicator Lamps LED type (RYB)-01Set.(d) Digital Voltmeter with built-in selectror switch -01No.(e) Digital Amperemeter with built-in selectror switch -01No.(f) CT coil set of suitable rating -01Set.(g) ON delay timer -01No.(h) Auto/Mannual operation selector switch -01No.(j) Aux Relay with 4No+4NC contactor -02Nos.(k) Aux Relay with 4NO contactor -02Nos.(l)Axial Air Flow fan 100mm sweep with thermostat-02Nos.(m) Control fuse 2A- 08 Nos(n) Control MCB,SP 6 Amp 10KA-02 NosOutgoing(a) MCB TP 40A 10KA ,415V rating - 03Nos.(b) MCB TP 25A 10KA ,415V rating - 02No.(c) MCB TP 16A 10KA ,415V rating - 03 No.(d) Cap duty contactor for 25KVAR -03Ns.(e) Cap duty contactor for 12.5KVAR -01No.(f) Cap duty contactor for 10KVAR -04No.(g) Capacitors type MPP-H as per IS 13585/hot I/1994/IS 13340/1993, for 100 (25x3+10x1+8x1+4x1+2x1+1x1) KVAR. 54 (h) Star/Stop push button-8 Nos.(j) On indication Lamp-8 Nos.(k) Fixed capacitor for transformer 4 KVAR with suitable rating MCBNote :-(i) The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specfically in all respects to high standards of engineering design and workmanship and shall be capable of performing in continous operation. 55 S&FHT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with PCC complete all as directed. 56 S&FLT cable/route indicator cast iron of suitable size along LT cable trench including planting in ground with PCC complete all as directed. 57 S&FPVC insulated multi stranded copper conductor wire ISI marked of size 2.5 Sqmm running through GI pipe bracketfrom fitting to pole/ junction box complete all as specified and directed by EIC. 58 COOLING APPLIANCES & AC ALLIED WORKS (SCH A PART-XI) 59 Supply and fix desert cooler GI body having base water tank of 20 SWG and top body 22 SWGof size 1000x800x800mm .The base tank have capacity of 60 ltr water fitted with float valve and incl three speed copper wound heavy duty electric motor single phase 240 volts of make Crompton,Khaitan,Bajaj and Symphony suitable for 4000 CFM with heavy duty submersible water pump complete fitted with indicator three phase selector switch ,pump control by seprate 5 Amp switch with cord flexible 2 mtr long fitted with top plug and duly painted as directed by Engineer-in-charge. 60 Supply, installation and commissioning of refrigerators, electric driven, 230 Volts, (single phase), 50 HZ, having nominal storage capacity 180 ltrs direct cool, Single door, 5 Star BEE rating, colour as approved by GE. 61 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA 62 S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA 63 S&F suction line/discharge lines copper pipe of suitable size as necessary at site, complete, all as specified & directed. 64 DG SET (SCH A PART-XII) 65 Supply, installation, testing and commissioning of trolley mounted mobile diesel driven silent generating set to give an out put of 100 KVA /80 KW at 415 Volts, AC supply, 50 HZ, 3 phase, 4 wire directly coupled to diesel engine, liquid cooled, mounted on 4 wheel trolley with common base plate complete with fuel tank of adequate capacity, vibration damper, other accessories, acoustic enclosure, alternator etc complete all as specified and as directed . The DG set shall offer best fuel economy, best comprehensive warranty terms on entire package including rubber components and lowest maintenance cost to give most economical power solution.The DG set shall offer lowest noise levels in its range and shall be CPCB certified for emissions and noise compliance to give environment friendly power solution.The generator set shall meet the stringent exhaust emission tests as per latest MoEF norms without sacrificing fuel efficiency at normal operating loads of following make and technical specifications :- Engine Make - Cummins, Ruston, Greaves Cotton, Cater Pillar, Ashok Leyland, Mahindra or as approved by GEAlternator Make - Stamford, Jyoti, Alstom, Areva, Crompton Greaves, Leroy Somer or as approved by GE 66 A.Engine Specifications:-Developing a net minimum power as per MoEF certified - 159 HP ( ± 5 % ), suitably matched with alternator to give a net directed output as specified. The engine shall be capable of delivering the required out put at 1500 RPM, as per BIS under NTP condition with provision of 10% overloading for one hours in every 12 hours of operation.The diesel engine shall also conform to IS : 10000/IS 1460/IS 13018/ISO : 3046/BS :649 / BS : 5514 as amended upto date. The scope of supply includes :-(i) Electrical starter motor 12V DC(ii)Battery charging alternator(iii) MICO fuel system (iv) Dual spin-on fuel filter(v)Turbocharger(vi) Residential silencer(vii) Dry type air cleaner(viii) Shut-off coil with safeties for LLOP/HWT(ix)Dynamically balanced fly-wheel and flywheel housing(x)First fill of lube oil and coolant 67 The technical data shall be all as specified below comprising of the following:-(i) BHP – suitable for giving a min power of 159 HPas per ISO 8528-Part-1/certified MoEF at the load terminals of alternator at 1500 rpm.(ii) All moving parts of the engine shall be mechanically guarded in such a manner that a human finger cannot touch any moving Part.(iii) Cooling – Liquid Cooled.(iv) Aspiration – Turbo Charged air cooled.(v)No. of Cylinders – 06.(vi)No. of cycles – 4 stroke.(vii) RPM – 1500.(viii) Fuel - HSD(ix) Fuel injection : Engine should have suitable fuel injection system in order to achieve low fuel consumption.(x) Starting System - 12V Electrical(xi) Lube oil specification – CI4 15W40.(xii) Governing specification – Electronic governor of class A1, as per ISO 3046/BS 5514 to maintain engine speed at all conditions of load.(xiii) Type of driven – Direct SAE flange coupling.(xiv) Battery capacity/rating – 12V DC, 88/90 AH.(xv) Any other item not included/specified, but is a standard design of the manufacturer. 68 ALTERNATOR :- The diesel engine mentioned herein before shall be coupled through flexible coupling to an indigenous synchronous alternator mounted on a strong mild steel fabricated common base frame, with AVM pads suitable for continuous operation at 1500 RPM, 415VAC, 0.8 pf (lag) suitable for 50 HZ, 3 phase, 4 wire system, brushless type, screen protected revolving field, self excited self regulated through an AVR all as conforming to IS 4722, BS 5000 & IEC:60034 as amended upto date.The alternator has the following features :-(i)Voltage Regulation -± 1.0% (max) in static conditions.(ii) Voltage variation - ± 5.0 %(iii)Class of Insulation - H Class(iv)Degree of protection - IP 23(v) Overload duration/capacity - 10% for one hour in every 12 hours of continuous use(vi)Frequency variation - As defined by the Engine Governor (± 1.0 %)(vii) Type of AVR( Automatic Voltage Regulator) - Electronic(viii) Stator Winding - Double layer lap(viii) Rotor - Dynamically balanced 69 Contrl Panel with microprocessor based monitoring and control system :-The control panel should be manufactured with 14/16 gauge CRCA sheet with powder coated for weather proof and long lasting finishThe control panel consisting Multifunction digital meter displaying the following parameters :- (i) Voltage (Phase to Neutral & Phase to Phase).(ii) Current.(iii) Frequency.(iv) Coolant temperature.(v)Engine Oil pressure.(vi)Power Factor.(vii) KWHR.(viii) DG Set running Hrs.(ix) Engine RPM.(x) Battery voltage.(xi) MCCB of suitable rating with overload and short circuit protections.(xii) Push button-switch or ON/OFF Switch for ON and OFF operation.(xiii) Aluminium bus bar with suitable capacity with in andoutgoing terminals.(xiv) LED Indicating Lamps set for Load On and Set Running.(xv)Insrument fuses duly wired and ferruled. 70 System operation : Manual Mode.(i) In a manual mode, it shall be feasible to start-up the generator set by the operator on pressing the start push button(ii) Three attempts starting facility shall be operative for the start-up function(ii)Alternator circuit breakers closing and trip operations shall also be through operator only by pressing the appropriate button on the panel and closure shall be feasible only after alternator has built up full voltage. If the load is already on ‘mains’, pressure on ‘close’ button shall be ineffective. 71 Engine shut down and alternator protection equipments : Following shut down and protection system with audio visual annunciation shall be integrated in the controller panel.1. For Engine :- (i) Low lubricating oil pressure.(ii) High/low coolant temperature.(iii)Engine over/under speed (iv)Low Fuel level.(v)High canopy temperatureFor Alternator :- (i) Over load) Short circuit)Earth fault) Over voltage) Over/Under frequency. 72 Battery/Electrical System -(i) Batteries of 12 VDC, 88/90 AH with copper cable of suitable sizes should be supplied with Genset are generally dry and uncharged. First charging of uncharged batteries is very important and should be done from authorized battery charging centre. Initial charging should be done for 72 - 80 hours.(ii) Batteries should be placed on stands and relatively at cool place. 73 FUEL TANK :- One No of sheet metal steel tank fabricated from 2mm thick MS sheet of suitable capacity to contain diesel for 8.0 Hrs running at full load including the following :-(i) Level indicator duly calibrated for indicating the quantity of diesel in the tank.(ii) Drain plug with 2 meter pipe for drain out.(iii) Fuel strainer.(iv) Pipe for fuel supply to engine.(v) Fuel pump manually operated for filling tank rotary type. 74 Acoustic enclosure:The acoustic enclosure shall be fabricated out of the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet conforming to MoEF/CPCB norms suitable for out door installation in exposed to weather condition and to limit over all noise level to 75 dBA at a distance of 1 Mtr at 75 % load or as specified by MoEF(Ministry of Environment & Forest). The enclosure has the following features:-(a) The construction should be such that it prevents entry of rain water splashing into the enclosure and allows free & quick flow of rain water to the ground in the event of heavy rain.(b)The hinged doors shall be made form not less than 16 SWG (1.6 mm) thick CRCA sheet and will be made air tight with neoprene rubber gasket and heavy duty locks(c) Designed to have optimum serviceability (d) Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship(e) Powder coated for long lasting service life and superior finish (f) Acoustic enclosures are supplied with built in Anti Vibration Mountings (AVM). As such Genset can be installed directly on the leveled surface(g) USE of special hardware for longer life(h) Insulation material meets exacting IS 8183 specifications for better sound attenuation. 75 (j) Flush styling - no projection (k) Fluid drains for lube oil & fuel.(l) The canopy should be as compact as possible with good aesthetic look.(m)Fuel tank suitable for 8 hours of operation(n) The enclosure is of modular construction with the provision to assemble and dismantle easily at site.(o) The sheet metal components are hot dip seven tank pretreated before powder coating.(p) The enclosure is powder coated (inside as well outside) with a special pure polyester based powder.All nut and bolts/external hardware is made from stainless steel.(q) There is provision for filling fuel from outside the enclosure with locking arrangement.(r) External drain plugs are provided for draining Lub. Oil and diesel.(s) The doors are gasketed with high quality EPDN gaskets to prevent leakage of sound.(t)The door handles are locking type.(u) Sound proofing of the enclosure is done with high quality rock wool/mineral wool confirming to IS 8183.The rock wool is further covered with fiber glass tissue and perforated sheet.(v) A special residential silencer is provided within the enclosure to reduce exhaust noise. 76 (w) Specially designed attenuators are provided to control sound at air entry and exit points.(x) Adequate ventilation is provided to meet total air requirement.If required, a blower is provided to meet total air requirement.(y)Temperature of enclosure does not exceed beyond 5 degree centigrade of ambient temperature.(z)The enclosure is provided with high enclosure temperature safety trip.(aa)Provision of emergency shut down from outside the enclosure.(ab) An arrangement for illuminating the enclosure from inside.(ac) The acoustic lining should be made up of high quality insulation material i.e. glass/mineral wool of minimum 50mm thickness and 75 Kg/cubic metre to 100 Kg/ cubic meter for sound absorption as per standard design of manufacturer’s to reduce the sound level as per CPCB norms. The insulation material shall be covered with fine glass fiber cloth and should be supported by perforated M.S. Sheet duly powder coated. 77 COUPLING & MOUNTING ARRANGEMENT : The engine and alternator are directly coupled by a SAE flange and mounted through AVM pads on a heavy duty steel base frame.The arrangement ensures that there is no chance of misalignment of the DG Set and vibrations of the DG Set are not transmitted to the base frame & to the enclosure.The fuel tank is mounted in the base of the enclosure.The batteries are kept in a separate tray inside the enclosure.COMMISSIONING:The DG Set shall be successfully commissioned by the contractor at the site as directed.TROLLEY SPECIFICATION : Fabrication of 04 wheel ( double axle ) trolley for mounting arrangement of DG sets with Fe 410 grade steel to hold the complete DG set of minimum platform size 4100 mm x 1250 mm and designed to carry minimum 4000Kgs weightwith the following Specification complete in all respect and as directed:-(i) MS Chassis - MC 200X75mm.(ii) MS Axle two Nos- 65X65mm.(iii) MS Chequered plate top - 8mm thick supported with suitable size angle and beams welded to Chassis and base plate.(iv) Rims and wheels - 4 Nos, tyer 7.5/16 inches (16 Ply) of make MRF/CEAT/Apollo.(v) Hydraulic Parking break - (vi) Towing hook of suitable size.(vii) Leaf springs suspension sets with U clamps - 04 Sets.(viii) Trolley shall be painted with two coats of synthetic enamel paint over a coat ofred oxide/ Zinc chrome primer of approved colour. 78 Exhaust System : DG Set sahll be fitted with retrofit Emission Control Device (RECD) to control exhaust emission limits as per latest guideline issued by CPCB And meet requirements of environmental (protection) Rule 1986. 79 BASKET BALL GROUND & VOLLEY BALL GROUND(SCH A PART-XIII) 80 M&L for 40mm pulley with nuts and bolts as specified and directed. (02 Nos for Basket ball ground & 02 Nos for Volley ball ground) 81 M&L for iron half baal cap all as specified and directed. (02 Nos for Basket ball ground & 02 Nos for Volley ball ground) 82 SOLAR POWER GENERATION 83 Design, Supply, Installation, Errection, testing and commissioning of roof top (on Grid Types) Grid connected Solar PV Plantcapacity (50kw*1) with Solar PV modules, tool kit and GI mounting structure with fasteners, nut bolt alongwith foundation in PCC 1:2:4, comprising and including of the following accessories. 84 Solar PV Module of Crystalline- Si (Poly/Multi) solar Modules should have efficiency more than 17%. 85 The PV modules shall be minimum with 72 cells of size 157mm x 157mm configuration with rated power of module ≥ 400Wp certified for solar PV module power performance tested as per IEC 61215 (Design qualification and type approval for Crystalline Si modules) and IEC 61730 (PV module safety qualification testing @ 1000 V DC of higher.with IEC2005. MAKE :- TATA BP/ EMMVEE / ELECTROMAC / INTER SOLAR 86 Photovoltaic modules shall carry a performance warranty of>90% during the first10 years, and >80% duringthe consecutive 15 years. Further module cell shall have performance warrantly of >97.5% during the first year of installation to get the maximum Performance of the System. 87 The module mismatch losses for modules connected to an inverter shall be less than 2%. 88 The SPV module shall be made up of high transmitivity glass & front surface shall give high encapsulation gain and the module shall consists of impact resistance, low iron and high transmission toughened glass. The module frame shall be made of corrosion resistant of aluminum material, which shall be electrically compatible with the structural material used for mounting the modules. 89 The module frame shall be made of Aluminium (non corrosion material), which shall be electrolytically compatible with the structural material used for mounting the modules with the Required No of Earthing of GI strip 25x2.5 mm size as required at site. 90 The terminals shall be connected to copper bus-bar arrangement. The junction boxes have suitable copper cable (As per site requirements) entry points fitted with cable glands as per recommendatoins of manufacturers. 91 Any type of Copper Conductor XLPE/PVC Insulated/sheathed/naked/flat/ Standard/Solid etc required for connection from Solar Power Panel of system to Inverter is to be included in the unit rate quoted. 92 (j) MPPT inverter power condition unit minimum 2 MPPT (250V to 960V)Economical(i)Maximum efficiency 98.5%.(ii)Opti Trac MPP tracking for best MPP tracking efficiency. (iii) Active temperature management.(iv)WIfi communication.Simple:(i)Three-phase grid feed-in, Grid voltage will be 415 volt. (ii)Cable connection without tools.(iii)DCplug-in-system.Flexible and future proof:(i)DC input voltage up to 1000V.(ii)Integrated grid management functions. (iii)Reactive-power capable. Make : -SOFAR SOLAR, ABB, DELTA, SOLIS 93 PCC 1:2:4 for foundation/ Pedestalfor the structure required deemed to be included in the unit rate quoted. 94 Supply, Installation, Errection, testing and commissioning of GI structure. Posmac/Hot dip for 100KW SPV systems with proper grouting PCC 1:2:4 type B1 which can with stand 150KM high wind speed so that the system can not get uprooted from ground due to high wind pressure. 95 Cost of lightening Arester ESE Type protection including Earthings Air termination and other accessories i.e. aluminium strip of 25X2.5 mm thick, nut bolts, washers, insulations etc requirement for connecting the system as recommended by manufacturer deemed to be included in the unit rate quoted. 96 Cost of tullu pump electrically operated with 0.50 HP Single Phase AC Supply motor and having head not less than 10mtr, necessary cable required for connection in PVC conduit heavy duty from existing nearest point to the motor starter and starter to motor, GI Pipe 15mm bore (medium duty) and PVC flexible braided pipe with set including all accessories from the Existing Service tank installed at the roof top of the building for cleaning of system. 97 Note :- (i)Cost of all the accessories from serial number listed in 20.02 to 20.14 is deemed to be included in unit rate quoted and nothing extra shall be admissible on this account. 98 M&L for fire exiguishert liquified CO2 gas capacity 10 Kg conforming to relevanty IS or ISI marked, complete, all as specified & directed: 04 Nos 99 Earthing complete with galvanised steel earth plate electrode 60×60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. 100 Earth continunity conductor or main earthing lead 32X6 mm galvanized iron strip fixed to wall on batten or recess or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requiredcomplete all as specified and directed. 101 Bi-directional net energy meter Showing Power generated by the Solar Power System, and total power used by the user deemed to be excluded in the rate quoted. Make : SECURE/L&T 102 AC Wire Any type of Copper Conductor XLPE/PVC Insulated/sheathed/naked/flat/ Standard/Solid etc required for connection from Solar Inverter and Connection to the existing system required to complete the solar system is extra 103 COLD ROOM 104 Supply, install, testing & commisssioning puff panel 1200 mm for wall and ceiling and floor with chequred plate and accessories room size 5x5x2.7 mtr and flush door 1200x1200x1200 mm clear opening and fright. 105 Supply, installation, testing & commisssioning CDU 3 phase scrolle R404 A 6.3 KW 106 Supply, installation, testing & commisssioning indoor unit R404 A 7.2 KW with heater defrosting 107 Supply & fix light fitting, light, light switchs, alarm bells and switches 108 Supply & Fix strip curtain
Contract Date: Jun 23, 2025 Contract Value : 19.25 Crore
Statutory Bodies & Commissions/Committees No of Bidders 11
Uttar Pradesh View Result →
14.
Defence #7389109 AOC
Tender For Provn Of Tech Bldg Alongwith Allied Infra Under Ge 860 Ews; 1 NOTE: Schedule ‘A’ Part - ItoPart -Xare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 2 Total amount of Sch A Part - I (BUILDINGS) 3 Total amount of Sch A Part - II(SITE CLEARANCE WORKS) 4 Total amount of Sch ‘A’ Part - III (INTERNAL ELEC SUPPLY) 5 Total amount of Sch ‘A’ Part - IV (PROTECTIVEWORKS) 6 Total amount of Sch ‘A’ Part - V ROAD WORKS) 7 Total amount of Sch ‘A’ Part - VI (AREA DRAINAGE WORKS) 8 Total amount of Sch ‘A’ Part - VII (LIGHTENING PROTECTIONWORKS) 9 Total amount of Sch A Part - VIII(DG SET WORKS) 10 Total amount of Sch ‘A’ Part -I X ( EXTRNAL WATER SUPPLY WORKS) 11 Total amount of Sch ‘A’ Part -X (EXTERNALELECTRIC SUPPLY WORKS) 12 SCH A PART - XI(Miscellaneous B/R and E/M works for Sch A Part-II to Part-XI)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 Supply and fixing Flame proof 8way distribution board for mounting MCB/RCBO/ELCB etc as per IS specification and CMRI approved.factory made fabricated out of cast aluminium alloy LM-6 grey epoxy powder coated finish, fitted with DIN channel neutrallink, Earth links and 200 Amps rated busbar . The DB shall be having IP-65 protection. The DBs shall also be consisting and includiing the following:-(a) MCB SPN 40 Amps, 240 Volts AC 50 Hz - 01 No(b) MCB SP 10 Amps, 240 Volts AC 50 Hz - 10 No 14 M&L for Painting lines, dashes, arrows, letters, etc. on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause. 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 Degress C, including cleaning and drying the road surfaces to ensure dust,oil,grease and moisture free surface beforeapplying paint complete all as specified as directed 15 S&F Convex mirror 80cm dia in size outdoor purpose including stand/ Pedestal embedded on PCC block 1:2:4 type B1 size 45x45x60cm and necessary earthwork complete all as specified and directed by Engr in charge. 16 S&F modified thermoplastic (polymer rubberised) speed breaker (retarders) with chequered design of size 250x365x50mm to resist compressive strength 30m tons in yellow and black colour fixed with anchor fastner bolt+material two component Epoxy adhesive A,complete all as specified and directed by Engr in charge. 17 Supply & Installation of silent CPCB approved 15 KVA NTP Disel generating set having diesel engine Liquid cooled, Electric start, four stroke, cold starting, Tci Aspirated, compression ignition, totally enclosed diesel engine with electronic governor direct coupled with15 KVA Three phase alternator at 1500RPM, 0.8 lagging power factor, providing three phase 415 Volts suitable for 50HZ, H class insulated winding Close-direct-coupled, self-excited and self-regulated type screen protected., mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS 4722, BS5000, IEC:34 and suitable for tropical condition, having fitted inside canopy fabricated out og 1.6mm CRCA sheet, cubical type, totally enclosed, powder coated, control panel and all accessories in-housed in a acoustic enclosure- sound proof canpoy.The DG set will be capable of oprating in temp range of (-) 35 degree centigrade to (+) 35 degree centigrade at an altitude of 4350 mtrs above mean sea level (MSL) complete with and including the following. 18 (A) Diesel Engine :- Adequate capacity of Diesel Engine as accepted by the accepting officer based on Manufactures technical details water cooled to drive independently above alternator and after considering derating as per site conditions after genertaing and reducing power consumed by accessories directly coupled through flexible coupling multi cylender multi stroke direct injection, Cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% foe half an hour in12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under.i) Fly wheel with housingii) Cooling system - Moulded radiator with fan & beltsiii) Cooling water pump - Centrifugal type belt driven. 19 iv) Exhaust system - Exhaust system complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of complete within the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger typeExhaust manifoldSilecer : Residual typeBellowsv) Fuel system - Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic govemer for 1% speed/ frequecy regulation.FuelfiltersFuel hosesVI) Lub oil systemLubricating oil filterLubricating oil pump 20 vii) Air Intake systemAir Intake manifoldAir cleanler dry typeviii) Govener : Electronic Governerix) Starting system : Electric self starter with maintaince free battery including battery charging alternator.(B) Batteries : Batteries of maintaince free of capacity as recommended by the manufacturer complete with copper conducter multistrnded leadsof suitable length from self starter tothe battery terminals complete with initial charge and initial fill of electrlyte all as specified of make as per OEM.(C) Starter gear ring : Start and stop push buttonIgnition Key/switchHandling and operation : Sailent features of accessories shall be as under.Radiator with blower fanCorrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governer controlled direct fuelinjection systemFly wheel housing and fly wheel. 21 (D) Generator monitoring control panel: Comprising of alstandard items as mentioned under this scheduleor as per standard practice ignition key switch and start/stop arrangement, indicators for engine parametes, hour run meter, RPM meter, Engine oilpressure indicator, water/coolent temparature indicator, Batery volt display including suitable size MCCBs and multifunction meter.x) Safety controls : Enginelow lube oil pressure high water temparature and over speeding of engine.xi) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling.xii) Accessories : AVM pads built or seperately mounted to manufacturer base framesxiii) Base frame : Made out of ISMC 250 of sturdy design madeof MS channel with necessory reinforcement and predetermined holes.xiv) MS pipe to and from the fuel tank to the DG Set. 22 (E) Alternator : Standard design alternator rated at 15KVA, net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3-phase 4-wire 415 Volts 50 HZ, 1500 RPM self exicited sekf regulated screen protected drip of IP 23 enclousure brushless design with widing in pole faces, insulating class H and voltage regulation of + 1% at rated voltage from no load to full load .The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply wit frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generallyconfirm to BS - 2613/5000/IS - 4722.i) Insulation class - Hii) Temparature rise class - Hiii) Excitation : Self excitediv) Regulation perfomance : The voltage is kept constant with + 1%, manual voltage adjustment with+ 5%.v) Frequency regulation+ 1%(F) Civil works : All civil works including PCC plat form & covered shed as per manufacturers design also 30cm above the ground . The depth of the foundation and PCC as recommended by the manufacturer. 23 (G) Rubber matting of LV grade 19mm thickof suitable size chequered type ISI marked to be laid in front of controlpanel should be provided.Note: The contractor shall arrange for artificial load for testing for final testing of DG set at site and the cost is deemed to be including in above offer.(H) Accoustic Enclousure : Manufacturedb by OEM suitable for 10 KVA DG set.i) NAL approved as per CPCBii) It should be as per latest rules and regulations of ministry of environment and forest and pollution control board.iii) The generating set battaries and control panel should be inside the enclousure.iv) Fuel tank should be outside the enclosure in the sub station building.v) The accoustic should be composite in construction and fully assembled integral unit.vi) The battaries should be placed inside the enclousure beside the DG set on a suitable insulatedplat form.vii) The DG set should be provided with external emergency stop push button.viii) The enclosure shoudbe suitably illuminated by suitable capacity of LED fittings/xi) The noise level should be 75 db ar 1m under free field conditions.xii) The accoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade shouldbe Genset Green. The base frame should be painted with epoxy based black shade.xiii) Fuel tank as per manufacturer recommendation with inlet and outlet connections and fuel level indicator.xiv) Base frame made out of suitable MS channels duly reinforced and provided with adequate numbers of anti-vibration pads to ensure minimum vibration as recommended by manufacturer. 24 NOTE ;(i) The Generator set prime mover willproduce at least 11 BHP on 15 KVA(ii) The quoted shall be deemed to be inclusive of necessary holes to wall including making good to distrbed surfaces so as to match with the existing finishes all as specified and directed.iii) The quoted rate shall be deemed to be inclusive of first filling of lubricant oil.iv) The quoted rate shall be deemed to be inclisive of 12 hours test run at site including of half an hour on 10% overhead in prwsence of representative detailed by accepting officer including FOL, all arrangements are to br made by the contractor for tests.(v) Provision of programmable timer for running bothDG set inalternate is included in the rates. 25 Supply laying & testing and commisioning from existing SWT to purposed SWT of Ductile iron (DI) class K-7 pressure pipe spigot and socket pipe centrifugally cast medium grade ISI marked with all fittings such as elbow, bends, rubber gasket joint, sockets, nipples, Tee and union etc complete laid in trenches for the 80mm dia complete all as specified and directed by Engr-in-Charge. 26 Supply and fix air release valve double headed for 80mm dia and fixed complete all as specified and directed by Engr-in-Charge. 27 Supply, installation andtesting puping set centrifugal Monoblock electric driven complete with all acccessories completeof capacity 5 HP 3 phase inclusive of staeter and PCC foundation complete using cement concrete (1:2:4) type B-1 using 20mmgraded stone aggregate including all GI fittings required at site like Tee, Bend, Elbow etc. The discharge of pump 420 lpm and head 16m complete all as specified and directed. 28 M&L for valve chamber foundation with 230mm thick brick wall in CM 1:6, 75mm thick coping in PCC 1:4:8 (Type B-1) , 15mm thick plaster in CM 1:4 overall internal and external wall surface, 50x50x5mm thick MS angle iron frame and 3.0 mm thick MS chequered plate cover with hinges and necessary locking arrangements painting with two coats of synthetic enamelpaint over one coat of red oxide primer all as specified and directed including dismantling and removing of existing damaged chamber except PCC foundation of internal size 900mmx900mm. complete all as specified and directed by Engr-in-Charge. 29 Supply, install, connecting, testing and commissioning cubicle compartmentalised outdoor type LT section pillar box size 0.6mx0.6mx0.45m, factory made, front and rear opening with locking arrangement, dust and vermin proof, fabricated out of 3.15mm thick CRCA sheet partition 2mm with canopy and base frame and mild steel angle iron stand, overall finished with epoxy powder coating, suitable for operation on 415 Volts, 50Hz, AC supply, includimg earthig stud, labelling etc and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 plateform, connect with electric supply complete all as specified and directed by Engr-in-Charge. 30 (a) Bus bar chamber having 4 aluminium strip Bus bar having air insulated and PVC sheathed 63A capacity fixed in position with required nuts bolts and porceline insulator etc.(b) MCCM 4 pole, 25KA, 415V, with adjustable thermal and fixed magnetic (Manual fixed type) of capacity 40 Amps (Incoming).(c) MCB SPN, 16 KA, 240V, of capacity 32 Amps (Outgoing for building)(d) MCB TPN, 10KA, 415V of capacity 16 Amps C curve (Outgoing for pump)(e) MCB TPN, 16 Amps 1 Nos (standby).(f) MCB SPN 6-32A Amps 01 Nos (Standby).(g) Street light timer 3KW- 01 Nos.(h) Volt meter 0-500 Volt meter digital type with selector switch.(j) Amp meter 0-100 Amp digital type with suitable CT and PT with selector.(k) Phase indicator lamp LED type.Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by Engr-in-Charge. 31 Provn of painring and numbering i.e applying one coat of black bitumenous paint on embedded portion, making five numbers alternative white & black strips 30cm height each (upto 1.50 metre height from top of PCC coping) with two coats of synthetic enamel paint over a coat of red oxide primer and painting the remaining external surfaces with two coats of aluminium paint over a coat of red oxide primer and numbering to the poles with synthetic enamel paint etx shall be deemed to be including in the quoted rate of above item. 32 Supply and fixing junction box PVC with locking arrangement of size (31cmx28cmx16cm) including 01 Nos 6 Amp SP MCB, 2 Nos bus bar of suitable size with suitable number of holes fixed on street light pole with suitable MS clamps all as specified and directed by Engr-in-Charge.
Contract Date: May 24, 2025 Contract Value : 5.79 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Apr 04, 2025 Contract Value : 43.60 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
16.
Defence #6886994 AOC
Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date: Feb 25, 2025 Contract Value : 47.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
17.
New and Renewable Energy #6517037 AOC
Bids Are Invited For Custom Bid For Services - Supply Of First Quality High Gloss Synthetic Enamel Paint Of Berger Or Asian Paints Or Shalimar Or Nerolac Or Akzo Nobel Make Paints Paint Shall Be Supplied In Colour Or Shade As Per Job Requirement And In Sealed And Wat.. , Custom Bid For Services - Supply Of High Build Epoxy Enamel Finishes Of Berger Or Asian Paints Or Shalimar Or Nerolac Or Akzo Nobel Make Paints Paint Shall Be Supplied In Colour Or Shade As Per Job Requirement And In Sealed And Water Tight Contai.. , Custom Bid For Services - Supply Of Zinc Phospate Primer Of Berger Or Asian Paints Or Shalimar Or Nerolac Or Akzo Nobel Make Paints Paint Shall Be Supplied In Colour Or Shade As Per Job Requirement And In Sealed And Water Tight Containers Of 4 Li.. , Custom Bid For Services - Supply Of Epilux High Build Coal Tar Epoxy Of Berger Or Asian Paints Or Shalimar Or Nerolac Or Akzo Nobel Make Paints Paint Shall Be Supplied In Colour Or Shade As Per Job Requirement And In Sealed And Water Tight Conta.. , Custom Bid For Services - Supply Of High Build Aliphatic Pu Paint Of Berger Or Asian Paints Or Shalimar Or Nerolac Or Akzo Nobel Make Paints Paint Shall Be Supplied In Colour Or Shade As Per Job Requirement And In Sealed And Water Tight Containe.. , Custom Bid For Services - Supply Of Exterior Grade Weather Coat Paint Of Asian Paints Apex Altima Or Berger Make Weather Coat Alguard Or Ici Dulux Weather Shield Max Or Equivalent Paint Shall Be Supplied In Colour Or Shade As Per Job Requiremen.. , Custom Bid For Services - Supply Of Epoxy Thinner Asian Paints Or Berger Make Or Ici Dulux Weather Shield Max Or Equivalent Thinner Container As Per Availability In Market Complete All As Per Specification And As Directed By The Engineer Incharge , Custom Bid For Services - Taking Delivery From Department Store At Kaiga And Applying First Coat Minimum 25 Micron Dpt For Anamel Paint 50 Micron For Epoxy Enamel 30 Micron For Zink Phospate 75 Micron For Coal Tar Epoxy 35 Micron For Pu Paint Per C.. , Custom Bid For Services - Taking Delivery From Department Store At Kaiga And Applying One Additional Coat Excluding Surface Preperation Minimum 25 Micron Dpt 50 Micron For Epoxy Enamel 30 Micron For Zink Phospate 75 Micron For Coal Tar Epoxy 35 Micro.. , Custom Bid For Services - Cleaning Of Tank Pipe Lines Equipments And Supports With Soap Solution And Water Cleaning And Washing The Work Areas With Clean Water As And When Directed And Disposing The Debris Or Waste Or Unwanted Materials Up To A Lea.. , Custom Bid For Services - Assistance For Cleaning And Painting Of Miscellaneous Pipe Lines And As Per Tender Specification One Skilled Manpower And One Semi Skilled Manpower , Custom Bid For Services - Assistance In Painting During Emergency Maintenance Activities In Overstay Or During Holidays By Skilled Manpower , Custom Bid For Services - Assistance In Painting During Emergency Maintenance Activities In Overstay Or During Holidays By Semi Skilled Manpower
Contract Date: Ref. Documents Contract Value : 64.94 Lakh
Government Departments No of Bidders 2
18.
Defence #6200916 AOC
Tender For providing Of 07 Deficient Company Stores At Mrc Sagar Under Ge Saugor-- 1 GENERAL SUMMARY 2 Lump sum price worked out by the contractor against Schedule ‘A’Part- I (BUILDING WORKS)for the following building works:- 3 (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH-1/22/2024 Sheet No. 1/1, CWE/ARCH-2/22/2024 Sheet No. 1/2 to 2/2 and Construction of 07 deficient company stores as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs/Government Engineering College before execution of work by the contractor. 4 Lump sum price worked out by the contractor for EXCAVATION ANDEARTH WORKas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) 5 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-III (Ref prepriced schedule attached seperately) 6 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-IV (Ref prepriced schedule attached seperately) 7 Lump sum price worked out by the contractor for PATH WORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately) 8 SCH A Pt - IX (MISCELLANEOUS PARTS) 9 M&L moorum/red bajrifilling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed. 10 Material and labour for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment overlaid on sand cusion of 25 mm thickcomplete all as specied and directed. 11 M & L for concealed point wiring for one light/bell or one ceiling fan/exhaust fan controlled by one one way switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 12 M & L for concealed point wiring for one 3 pin/5 pin 5 Amps socket outlet on same board with other switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 13 M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 14 M & L for concealed point wiring for one switch 5/6 pin 5/15 Amps socket on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.50 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 15 S&F modular 5-step speed fan Regulator of electronic type suitable for BLDC ceiling fan of 1200mm/1400mm sweep Hum free & speed variation not less than 120 watt, socket type in size complete all as specified and directed 16 S&F testing and commissioning of MCB SP 6-32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. 17 S&F double door metallic sheet metal enclosure for MCB DBdouble door4 way 230 Volts with 200 Amps rated bus bars.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate complete all as specified and directed. 18 S&F in replacement of SPN 32 Amps415 Vincluding making electrical coming/outgoing connections with lugs/thimbles,including taking down complete all as specified and directed. 19 M&L LED TL fitting 20 watt for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PChousing in opeal finish coverwith high brighness complete all as specified and directed. 20 S&F LED Bulk head designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. 21 M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself 22 Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCB, TPN, 415V, 50HZ, 63 Amps 10 KA - 01 No. (B) OUTGOING (i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED TypePhase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 Set (iv) MCB, SPN, 230V, 50HZ, 20 Amps with rupturing capacity 10 KA - 05 Nos(v) Blank space for MCBs SPN - 02 Nos 23 M&L for40 mm dia GI pipe light grade laid under road and path for passing cable complete all as specified and directed. 24 M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI strip 25 X 4 mm by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself
Contract Date: Jan 06, 2025 Contract Value : 34.87 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
19.
Power #5254782 AOC
Tender For Miscellaneous Civil Maintenance Works At Kaiga Generating Station 3&4, Kaiga For The Year 2024-2026.; 1 Earthwork Excavation in all Sorts of Soil for foundation trenches, walls, drains, plinths, footings, pedestals, columns and for all other miscellaneous foundation works etc., including Cutting / removing & clearance of jungle, bushes, grass & creepers etc. Shoring, strutting, bailing out water [if necessary], dressing, leveling & hand ramming he bottom of foundation base using wooden hand rammer with proper watering, refilling the sides of the foundation with excavated available good quality of Soil, leveling & hand ramming the sides of foundation base using wooden hand rammer with proper watering, providing; fixing & removing necessary staging / platform / ladder, collecting & disposing the waste soil or surplus soil, generated waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift / height. 2 Providing and filling the Soil selected good quality soil brought from the borrow pits and filling Low laying areas etc., to the required gradient, camber, leveling and cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. NOTE: Measurement will be made on the basis of dimensions of vehicle trailer. 3 Providing and laying PCC 1:2:4 using 20 mm & downsize clean, crushed, well graded, aggregates of hard, durable & approved quality including mixing, transporting, laying, spreading, consolidation, leveling, finishing including curing, providing; fixing and removing necessary form work, cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 4 Providing and laying RCC 1:1.5:3 using 20 mm & downsize clean, crushed, well graded, aggregates of hard, durable & approved quality for RCCworks including mixing, transporting, laying, spreading, consolidation, leveling, finishing, curing and cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. 5 Providing, placing and removing formwork for all in-situ concrete works such as foundation, rafts, footings, pedestals, plinth, columns, beams, slabs, Chejjas, Lintels, bedding, platform, pathways, walkways and all other miscellaneous RCC works [All RCC works below & above plinth level] including Providing; fixing & removing necessary staging / platform / scaffolding / ladder [if required], preparation of base, cleaning the work area, collecting & disposing the construction & generated waste up to a lead of 2 to 3 kms. from the place of work etc. complete all as per standard technical specification and as directed by Engineer-In-charge at all locations and at all lift & height.Note: The measurement for the form work will be actual area of form in contact with the concrete surfaces. 6 Providing and laying approved make high strength deformed Reinforcement bars of all diameters confirming to grade Fe-500DIS: 1786 including cutting, bending, transporting, placing in position & binding with suitable gauge soft annealed binding wire of approved quality for all insitu concrete works including providing & placing suitable cover blocks, scaffolding / staging, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 7 Providing and constructing Masonry [below plinth & above plinth] with C.C. Solid Blocks of size 400/300 mm X 200mm X 200/150mm or size as approved by the engineer-in-charge size, having crushing strength not less than 45 Kgs. per SqCM. in C.M. 1:5 including simultaneous flush pointing, providing & removing necessary scaffolding / staging /platform, curing, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. 8 Providing and laying Internal Cement Plaster 15 mm thick in CM 1:5 to the masonry & concrete surfaces etc., rubbed perfectly so as to obtain smooth & even finish including preparation of base by racking out all the masonry joints & close hacking the concrete surfaces for properbonding, curing, providing; fixing & removing necessary scaffolding / staging / platform, cleaning the work area, collecting & disposing the construction waste up to a lead of 2 to 3 kms. from the place of work etc. complete all as per specification and as directed by Engineer-in-charge at all locations and at all lift & height. 9 Providing and laying External Cement Plaster 18 mm thick in Two Coats. Base coat shall be 12 mm thick in CM 1:5 & finishing coat shall be 6 mm thick in CM 1:3 (sponge finished) with Non-Shrink Water Proofing Compound [confirming to the BIS 2645 of the latest edition] @ 2 % by the weight of cement / as per the recommendation of the manufacturer to the Masonry surfaces & concrete surfaces etc. rubbed perfectly so as to obtain smooth & even finish including preparation of base by close hacking / chipping the old surface, racking out the joints & cleaning, curing, providing; fixing & removing necessary staging / platform / scaffolding, collecting & disposing the generated waste, construction waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard technical specification, drawing and as directed by engineer-in-charge at all locations and at all lift & height. 10 Providing and applying One Coat of Interior Grade Primer [of superior 1st quality & of standard make] and Two Coats of Interior Grade Acrylic Plastic Emulsion Paint [superior 1st quality & of standard make], of shade /colour [as per site requirement & as selected by engineer-in-charge], over the interior surface of newly plastered / concrete or masonry wall, RCC members such as columns; beams & other concrete surfaces, including providing & applying Two Coats of Acrylic Putty, [of superior 1st quality & of standard make] to the entire surface, preparation of surfaces by sand papering properly before application of putty; primer & paint. Putty, Primer & Paint shall be confirming relevant BIS specification of latest edition, providing; fixing & removing necessary staging / platform / scaffolding / ladder [if required], collecting & disposing the generated & construction waste, up to a lead of 2 - 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations & lifts / heights. 11 Providing and applying One Coat of Exterior Grade Primer, [of superior 1st quality & of standard make] and Two Coats of Exterior Grade weather Proof Paint [of superior 1st quality & of standard make], of shade / colour [as per site requirement & as selected by engineer-in-charge], for New Surfaces of concrete, plaster or masonry wall, RCC members such as columns; beams & otherconcrete surfaces including providing & filling Crack Sealing Compound [of superior 1st quality & of standard make] in the cracks, preparation of surfaces by sand papering & Pressured Water Jet machine, cleaning the surface, surface shall be neat; clean & dry before application of crack sealing compound, Primer & paint. Primer, Paint & Crack Sealing Compound shall be confirming relevant BIS specification of latest edition, providing; fixing & removing necessary staging / platform / scaffolding / ladder [if required], collecting & disposing the construction & generated waste up to a lead of 2 - 3 kms. from the place of work & cleaning the work area etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift & height. 12 Providing and fixing in position 18 - 20 mm. thick, one side Mirror Polished Granite Stone Slabs of approved size; of approved quality; of approve shade / colour &Laying / fixing in approvedpattern for flooring, Skirting, Platforms etc. to the true line; level & slope etc, including fixing / laying the Slabs using cement mortar inCM 1:4; 20 mm. thick bedding, cement [for bedding @ 4.4 Kgs. per Sqm. of floor area] for slurry, cement [for joints @ 0.60 Kgs. per Sqm. of floor area] for slurry & colouring pigment to match the existing surface, preparation of base & curing properly, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. 13 Providing and laying Ceramic Wall Tiles of different size for dado of approved make, Size, colors /shade, laid on 12 mm thick in CM 1:4 including grouting the joints with white and matching pigment as per specification and relevant IS, including preparation of base and collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 14 Providing and laying premium quality Ceramic Anti Skid 11/2 X 11/2Tiles for floor, of approvedbrand & shade / colour with 20 mm thick in CM 1:4 bedding, grout filling in the joints with matching pigmented cement slurry, finished to true line & levelsgradient etc., including cutting of tiles, preparation of baseand collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 15 Providing, fabricating and fixing in position Mild Structural Items like pipes, angles, flats, plates, other approved sections etc., including the cost of nuts, bolts /anchor fasteners for fabricating & fixing different Mild Structural Steel works such as gates, grills, trusses and all othe Mild Structural Steel works etc., including providing & painting One Coat of Metal primer [superior quality & make] and Two coats of synthetic enamel paint [Paint shall of superior quality and make with approved shade /colour] including preparation of base, providing, fixing and removing necessary staging / platform / scaffolding, all materials shall be confirming to the relevant BIS specification of the latest edition, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 16 Providing and laying 40 mm. thick, Indian Patent Stone for Flooring, Steps, Landing & Ramps etc. with PCC 1:2:4 using 10 / 12 mm. & down size, clean, crushed, well graded, cubical shape, sharp edged aggregates of hard, durable & approved quality stones / rubbles including machine mixing, transporting, laying, spreading, compaction, laying in baysto proper line; slope or level etc. using 6 mm. thick plane glass dividing strips for flooring, steps, landings & rampsincluding smooth finish, Curing, providing; fixing & removing scaffolding / staging / platform, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. 17 Providing and laying / fixing Plane or Curved Galvalum Sheets for Roofing, Ridges & Cladding etc.[0 .47 mm thick] of Colour Mat Finish Coating: AZ - 150 / 550 MPA, Paint : RMP [Regular Modified Polyester], Top Coat: 18 - 20 Micron, Bottom Coat: 5 - 7Micron, Trapezoidal Profile 0.47 mm thick at pitch 250 mm., Width 1060 mm, Length as per site measurement, Aluminium - Zinc Steel Sheet [Galvalum Base] 55 % aluminium, 43 % Zinc, 1.60 % Silicon with Tensile strength of 345 to 550 MPA including providing & fixing necessary self drilling screws of best quality & EPDM washers, Galvalum sheets Roofing with Galvalum Ridges shall be of approved shade / colour & confirming to the relevent BIS specification of the latest edition and of approved make, preparation of base, providing; fixing & removing Staging / platform / ladder, collecting & disposing the generated waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift / height. 18 Providing and fixing 2 mm thick, PVC flooring of Tusker brand from M/S Krishna Vinyls or Royal House brand, ofapproved shades and pattern with necessary adhesiveof approved quality & shall be used, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 19 Providing,fixing / placing in position Rotary Press; Heavy Duty; Anti Skid; 5-Star; Short Blasted; Paver Blocks of 65 mm thick [of standard size & in colour combination of terracotta & black and as selected by engineer-in-charge] of approved & reputed make & of superior 1st quality. Paver blocks compressive strength shall not be less than 300 Kg/Sqcm and manufactured as per IS 15658-2006, Paver shall be laid over well Saturated 50 mm. thick River Sand / M-sand bedding including preparation of base by proper dressing / leveling and ramming [using Plate Vibrator to have uniform surface and to get the required line & level / gradient, camber] the base with proper watering, the gaps shall be filled with fine sand, ramming top surface of pavers using Plate Vibrator to have uniform surface and to get the required line & level / gradient & camber, providing; fixing & removing necessary staging / platform, collecting & disposing the generated waste up to a lead of 3000 meters from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specificationand as directed by engineer-in-charge at all locations and at all lift / height. 20 Providing and fixingSS 316 grade,18 to 20 gauge,thick pipe of 50 / 40/ 32 NB or suitable square / rectangle sections [thickness of wall shall be minimum 5 mm.] for staircase railing / handrails work including fabrication as per drawing and site requirement, transportation and fixing in the location by using suitable anchoring bolts, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 21 Providing and fixing in position factory made Wood plastic composite (WPC) Door Shutters 30mm thick.The entire shutter shall have glossy polishwith IS specification including providing & fixing [to each shutters] One number of 250 mm long &16 mm dia. Aldrop, One number of 200 mm long & 10 mm dia. Tower Bolt; One number of 150 mm long& 10 mm dia. Tower Bolt, Two numbers of 125 mm grip D handles, Two numbers of 40 mm dia. & 50 mm long rubber bushes[Aldrop,Tower Bolts & D handles shall be of approved make Stainless steel material], preparatation of base, providing; fixing & removing necessary staging / platform / ladder, collecting & disposing the generated waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift / height. 22 Providing, fabricating and fixing in position Pre-Coated Aluminum Composite Panels of approved colour / make with exterior grade coating and 4 mm. thickness (TCT) using powder coated “JINDAL” or Hidalco” make Aluminum extruded sections as base grid frame mounted on anti corrosive treated SS brackets including fixing the panels, tray type and sealing with down corning make weather sealant structural silicon sealant with necessary masking to the panels, providing, fixing and removing necessary staging / platform / scaffolding, all materials shall be confirming to the relevant BIS specification of the latest edition, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 23 Providing and fixing Wall Cladding with 12 mm thickwater proofply woodas per IS: 303 AA Type over2 ½” size GI ‘U’ channels at 600 mm centre to centre fixed to the wall with necessary stainless steel screws; fasteners, and providing and fixing 3 mm thick Vineer over ply woodpaneling, including required screws; adhesive; pins; grips for joints; making grooves; rebates; moulding & finishing smooth with sand paper including applying three or more coats of natural Finish with melamine Polish, fixing and removing necessary staging / platform & cleaning the area etc., complete as per drawing and as directed by the Engineer-In-Charge etc.,complete allas per manufacturers technical specification and as directed by Engineer-In-Charge at all locations. 24 Providing and laying/fixingDecorative with architectural finish Suspended False ceiling using first quality PVC Boards of size 300mm X 3000mm X 6mm of approved makewith GI Grid Work of 600 mm. x 600 mm. made out of Perimeter channels [MF 6A], Ceiling Sections [MF5 : placing at 457 mm. (Maximum) C/C] , Intermediate channels[MF7: placing @ 1220 mm. (Maximum) C/C], Ceiling angles 25 mm X 25 mm. Size, placing @ 1220 mm. (Maximum) C/C] including Screws, soffit cleats, nuts & bolts, connecting clips and all other required miscellaneous materials & consumable of approved first quality/make etc., all materials shall be confirming to the relevant BIS specification of the latest edition,providing; fixing & removing necessary staging / platform, cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 meters from place of work etc.,complete all as per standard/ manufacturers specifications and as directed by Engineer-In-Charge at all locations & all lifts / heights. 25 Providing and fixing GI 2 ply X 4 bails barbed wire of 12 gauge, of approved quality & confirming to the relevant BIS specification of the latest edition on the Y / L shape existing RCC / MS fencing posts including providing & binding / tying with GI wire of 18 gauge or split pins to the existing post,providing; fixing & removing necessary staging / platform, cleaning the work area & and disposing the debris up to a lead of 2000 meters outside the periphery of work premises, cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations.Note: Galvanization shall be as per relevent IS code. 26 Providing and fixing Iron Galvanized concertina coil, cross Razor of610 mm dia / 750 mm dia. / as directed by EIC and Fixingover Y shape RCC posts / MS fencing posts / MS Gates , along with providing & fixing 4mm dia. GI wire including providing and tying using J clips and tying with suitable gauge GI wire [J clips and GI wire shall be of suitable gauge, of standard make] at regular interval by maintaining the proper & required pitch distance including preparation of base, providing; fixing & removing necessary staging / platform, collecting & disposing the generated waste up to a lead of 2 to 3 kms. fromthe place of work & cleaning the work area, etc. complete all as per standard & manufacturers technical specifications, drawing [in any] and as directed by engineer-in-charge at all locations and at all lifts / height. 27 Providing and fixing Vertical venetian blinds of Vista Levolor Dustguard No -103 or equivalent or as approved by EIC with all necessary fittings & fixtures of approved shade / colour, of required size, providing; fixing & removing scaffolding / staging / platform, collecting and disposing the generated waste & all unwanted materials upto lead of 2000 - 3000 meters from place of work etc., complete all as per specification, as per manufacturers technical specification and as directed by engineer-in-charge at all locations. 28 Providing and fixing in position Premium Quality, Double charge nano finish Vitrified [straight edge] Tiles for flooring,Skirting & dado of Johnson / Bell / Regency / Marbit o/ Nitco / Naveen diamontile / Somany make of approved shade / colours [as per the design] including laying in CM 1:4, 20 mm thick, base layer for flooring, in CM 1:3, 12 mm thick, base layer for Skirting & dado, Cement Slurry @ 3.3 Kgs [for flooring, skirting & dado] per sqm. or using approved adhesive [such as laticrete L290, laid thickness of laticrete shall not be less than 6 mm], pointing the joints neatly with white cement mixed with matching [tiles] colouring pigment, including preparation of base by close hacking / chipping the concrete / plastered surfaces, racking out the adjoining masonry joints & cleaning, curing etc., providing; fixing & removing necessary staging / platform / ladder, collecting & disposing the generated waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift / height. 29 Providing and fixing in position Display Boards consisting of PU spray painted PVC foam letters fitted over ACP sheet boards, including fabrication of frames, letters, ACP board etc.; including transportation, installation, removal of existing display board etc. & cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000- 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. Note: (1)The pvc foam sheet used for letters should have density of 0.55, (2)Frame shall be made using GI Square tube section of 1 X 1 & 2mm thick, (3)ACP sheet shall be of bending quality & 3mm thick, (4)PVC foam letters shall be PU spray painted & 18mm in thickness, (5)Letters shall be fitted on board using nut and bolts of suitable size. (6)Letters are to be made trilingual i.e. Kannada, Hindi & English. (7)Main body of the Letters will only be considered for size measurements of Kannada & Hindi letters. 30 ACP sheet boards along with GI frame work as specified above. 31 PU spray painted PVC foam letters as specified above having size: 4inch to 5inch 32 PU spray painted PVC foam letters as specified above having size: 6inch to 8inch 33 PU spray painted PVC foam letters as specified above having size: 9inch to 10inch 34 PU spray painted PVC foam letters as specified above having size: 11inch to 12inch 35 Providing, laying & concreting in position / Placing of RCC Pre-Cast drain/ trench Slab Covers made out of RCC 1:2:4 casting with slots of 75 mm or 50mm or as directed by the Engineer-in-charge thickness including mixing, transporting, laying, spreading, consolidating, leveling, smooth finishing the all exposed faces, providing; fixing & removing necessary formwork, curing properly, Providing and tying reinforcement Steel Bars for RCC pre-cast covers / slabs of approved quality [Fe-500D steel bars shall be confirming to the BIS 1786 - of the latest edition] sealing the joints in CM 1:2, Stacking & disposing debris upto lead of2Kms etc. complete all as per specification and as directed by the Engineer-in-charge at all locations.Note: 1) Reinforcement steel & formwork will be measured & paid under relevant items.(2) Precast slabs shall be cured properly & placed in position after 28 days from date of casting. 36 Engaging Excavator (JCB) for removal & disposal of road side collapsed soil / earth; stone boulders; wooden logs; dried trees & other unwanted materials / things which are making obstruction for free movement of men & vehicles etc., cleaning of existing drains for free flow of rain water, formation of new drains for free flow of rain water and other miscellaneous works etc. including hire charges of Excavator; operator wages; Excavator maintenance charges; cost of diesel & lubricants and tool & tackles etc. cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000- 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. 37 Providing Clear / tinted Glass of minimum 5.5 mm thick including safe delivery at Kaiga site. Glass shall be free from any defects (glass shall be of superior quality& of first grade) of Modi / Saint Gobinmake & confirming to the relevantBIS specification of the latest edition.Note: Contractor shall take clearance from Engineer-In-Charge prior to bulk supply of material. 38 Providing 20 micron thick, Sun Control Film of GARWARE or equivalent make, of approved quality, colour/ shade & confirming the relevant BIS specification of latest edition.Note: Contractor shall take clearance from Engineer-In-Charge prior to bulk supply of material. 39 Providing 12 mm thick, BSD, Interior Grade Pre-laminated Partical Board of superior & approved quality of ONZE / equivalent make and confirming to the relevant BIS specification of the latest edition for wallpartitions, doors & allother miscellaneous works. Note: Contractor shall take clearance from Engineer-In-Charge prior to bulk supply of material. 40 Providing StainlessSteel edge protection angle of size 50mm X 50mm X 3mm thick (minimum) & 1.5 meter in length; including providing 8 nos. of suitatble size holes for fixing of S.S. screws for fixing the angle in the wall edge portion and including providing suitable size S.S. Screws along with PVC hole plugs of required nos., of superior & approved quality confirming to the relevant BIS specification of the latest edition. Note: (1) The length of single edge protection angle may change as per site requirement. (2) S.S. screws shall be flat head and should flush with Angle surface. (3)Contractor shall take clearance from Engineer-In-Charge prior to bulk supply of material. 41 Providing Aluminum Jalleyof50 X 50 mm. (Opening) X 6.5 mm thick (Minimum) of Square or diagonal pattern 50 X 60 mm. (Opening) X 6.5 mm thick (Minimum) of Square or diagonal pattern, fabricated out of extruded annodised aluminum sections confirming to the relevant BIS specification of the latest edition, including providing U channels and required screws. Note: (1) The length of U channel and required screws shall be supplied along with aluminium jally considering grill of size 2.4m X 1.2m.(2)Contractor shall take clearance from Engineer-In-Charge prior to bulk supply of material. 42 ProvidingAstral / Finolex / Supreme / Ashirwad or equivalent make CPVC Pipes , Fittings, & CPVC solvent etc.[Pipes & Fittings shall be of class SDR 11, of plumbing quality of and confirming to the IS:15778 specification of the latest edition]. 43 CPVC Pipe 20 mm 44 CPVC Pipe 25 mm 45 CPVC Pipe 32 mm 46 CPVC Pipe 40 mm 47 CPVC Pipe 50 mm 48 CPVC Coupler 20mm 49 CPVC Coupler 25mm 50 CPVC Coupler 32mm 51 CPVC Coupler 40mm 52 CPVC Coupler 50mm 53 CPVC Equal T 20mm 54 CPVCEqual T 25mm 55 CPVCEqual T 32mm 56 CPVCEqual T 40mm 57 CPVCEqual T 50mm 58 CPVCReducer T 32mm X 25mm 59 CPVCReducer T 50mm X 32mm 60 CPVC 90degree Elbow 20mm 61 CPVC 90degree Elbow 25mm 62 CPVC 90degree Elbow 32mm 63 CPVC 90degree Elbow 40mm 64 CPVC 90degree Elbow 50mm 65 CPVC solvent in standard packing 66 Fabricating, providing and fixing in position Stainless steel (304 grade) NPCIL logo having size 26(+/-2)inch in overall height, 20(+/-2)inch in dia for round part of logo & 0.8 to 1 inch in thickness, including transportation, installation, removal of existing display board etc. & cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000- 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. Note: (1) NPCIL logo design shall be made by making grove using lesser machine over Stainless steel (304grade) gold in colur sheet and embossing to 1 inch. 67 Fabricating, providing and fixing in position Stainless steel (304 grade) Letters having size 9 to 10 inch & SS sheet of 0.8 to 1 inch in thickness , including transportation, installation, removal of existing display board etc. & cleaning the work area, collecting and disposing the generated waste & all unwanted materials upto lead of 2000- 3000 meters from place of work etc., complete all as per specification and as directed by engineer-in-charge at all locations. Note: The letters shall be made using Stainless steel (304grade) gold in colour sheet matching to the colour of NPCIL logo and embossing to 1inch. 68 Providing, laying / fixing CPVC Pipes [SDR 11] with its all required Plain & brass threaded fittings [such as collars, elbows, tees, unions, coupling, reducers, enlargers, bends, nipples and all other fittings required for completing the job, as per code of practice for water supply to the buildings -BIS 2065ofthe latest edition, of superior 1st quality, of standard make and confirming to relevant BIS specification of latest edition] including fixing on the wall with suitable PVC clamps, jointing the pipes & fittings using CPVC solvent, cost of all materials like white or red lead, clamps, cement, sand, tools & tackles, testing the pipe with clean water [as per specification] and ensuring smooth functioning, providing; fixing & removing necessary staging / platform / ladder / scaffolding [if required], preparation of base,collecting & disposing theconstruction & generated waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lifts / heights.FIXING ON WALL SURFACE [Inside / Outside Bldgs /trench] 69 25 mm dia. FIXING ON WALL SURFACE [Inside / Outside Bldgs/trenches] 70 32 mm dia. FIXING ON WALL SURFACE [Inside / Outside Bldgs/trenches] 71 50 mm dia. FIXING ON WALL SURFACE [Inside / Outside Bldgs/trenches] 72 Dismantling / breaking / removing by Manual or Mechanical means PCC with both side plaster, in cement mortar & other finishes [if any] including collecting & stacking neatly; all serviceable materials [such as stone aggregates] in sectional store, providing; fixing & removing necessary staging / platform / scaffolding / ladder [if required], collecting & disposing the generated & construction waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift. 73 Providing and fixing in position factory made 45 mm thick Single/double leaf, hinged metallic stability, integrity and insulation fire barrier doors of 60 minutes fire rated confirming to IS:3614 (part-I & II) including providing & fixing cement sand grouted door frame with necessary fixtures, intumescent strip, Stainless steel ball bearing flat button hinge with machine Screws (4 Pieces per leaf), GEZE Overhead rack and pinion door closer GEZE TS 1000 C, EN 2/3 & 4 with adjustable closing speed and adjustable latching action with mounting plate (01 piece per leaf), Vision Panel 200mm (width) X 300mm (height) X 6 mm (thick) made ofFire rated clear Glass (01 piece per leaf), 250 mm long &16 mm dia. Aldrop (2 pieces perdoor), Stainless Steel D Handle (19x250mm) (2 pieces leaf). Specifications : (1)The thickness of sheet used for door shutter shall be 1.2mm, (2) Insulated with Honeycomb / rockwool, (3) GI material shall be used for frame & shutter, (4) Frame & door shall be powder coated, (5) Frame profile shall be 105mm X 75mm and (6) The thickness of sheet used for shutter frame shall be 1.2mm. Including preparation of base, providing; fixing & removing necessary staging / platform / ladder, collecting & disposing the generated waste up to a lead of 2 to 3 kms. from the place of work & cleaning the work area,etc. complete all as per standard & manufacturers technical specification, drawing [if any] and as directed by engineer-in-charge at all locations and at all lift / height.Note: (1)The contractor needs to submit manufacturer test certificate for confirming the fire rating of full assembly of fire barrier door.(2) Approximate size of single door openingis around 750mm X 2100mm.
Contract Date: Dec 03, 2024 Contract Value : 1.78 Crore
Boards / Undertakings / PSU No of Bidders 2
20.
Defence #3710053 AOC
Tender For Provision Of Urc At Af Stn Sulur; 1 GENERAL SUMMARY(Note : Schedule A Part I Building/ Structure is not pre priced by MES and the pre priced rate indicated as Rs. 0.00 under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6) 2 Schedule ‘A’ Part I“BUILDING/STRUCTURES ” M&L for Design, supply and erect Pre-engineered steel bldg steel structure of Internal size 15M x 30Mwith Ridge height as per design and 3.5M height at both ends, with Alu-zinc coated colour profiled sheet, Roofing sheets 0.50 mm thickness and yield strength of 550 mpa in wall cladding and roofing (approx 15% roof/wall sheeting with 2mm thick Polycarbonate sheet with integrated wire mesh) incl RCC foundation and plinth upto0.45m above ground level, AAC blockmasonry cubicals of height 2.4m with 03Nosaluminium doors, ceramic tile flooring, Plinth protection, anchor bolts, base plates and all structural steel items, rain water gutters and down take pipes with entry and exit doors with steel frames and shutters, aluminium doors, turbo air ventilators and Exhaust fanscomplete all as specified and as directed by GE 3 Schedule ‘A’ Part I“BUILDING/STRUCTURES ” M & L for Design, construction of Toilet facilities for Unit Run Canteen for Staff and Visitors with permanent specifications such as RCC M-25 (Design mix), framed construction with AAC solid block masonry, ATT and PU based water proofing treatment etc etc complete all as specified and as directed by GENote : - (i)The contractor should design forundation and super structure for the building andthe foundation should be designedaccording to the soil report and structural drawingsof the entire structureshall be submitted after vetted from IIT/NIT/IISC Bangalorealong with design calculation sheet.(ii) The toilet block shall be desinged and built according to the architechtural drawings along with schedule of finishes.(iv) Detailed yard stick along all connected documents shall be submitted before execution of the work for approval of accepting officer. Quoted rates are deemed to be included for all these provisions 4 GENERAL SUMMARY(Note : Schedule A Part II to VII are prepriced by MES under Ser No.4 and 5.Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only) 5 Total of Schedule ‘A’ Part II “INTERNAL ELECTRIFICATION” 6 Total of Schedule ‘A’ Part III “ PATH/ HARD STANDING” 7 Total of Schedule ‘A’ Part IV “ AREA DRAINAGE” 8 Total of Schedule ‘A’ Part V “ SEWAGE DISPOSAL” 9 Total of Schedule ‘A’ Part VI “ INTERNAL WATER SUPPLY” 10 Total of Schedule ‘A’ Part VII “ EXTERNAL WATER SUPPLY” 11 Total of Schedule ‘A’ Part VIII “ EXTERNAL ELECTRIC SUPPLY” 12 Sch A Part-IX - MISCELLANEOUS ITEMS(Note : This schedule is not pre priced by MES and the pre priced rate indicated as Rs. 0.00 under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6) 13 S & F modular flush box for mounting of modular cover plates 8 modules complete all as specified and directed 14 M &L for Cutting80mm dia cast iron and reducing to required length before laying pipes in position for insertion of new tees,branches of different sizes as per site requirementcomplete all as specified and directed 15 M & L for Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed. 16 M & L for Protection to cable with one layer of Fly ash bricks of size 23 x 10 x 10 cm laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cablecomplete all as specified and as directed. 17 S&F angle cock, cast copper alloy fancy type chromium plated with long shank & cup concealed type for PPR pipe of 16mm borecomplete all as specified and as directed. 18 S&F LED light fitting 1 X 10 W, 220 V AC decorative box type with driven holder incl LED tube light connecting three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 19 S&Fsteel body exhaust fan with lovers of size 300nmm sweep, 900RPM 230 volts single phase AC supply complete with bolts, nuts and washers suitably embedded in the wall/ prefabricated sheet etc including making suitable opening and provisioning of flexible cord copperof size 23/ 0.0076 from ceiling rose to exhaust fan for giving connectioncomplete all as specified and as directed. 20 S&F LT panel outdoor type (CPRI approved) made out of ms sheet 3.15mm thick angle iron of size (50x50x6 mm) with locking arrangement and painting with following asseccories suitable for incoming/outgoing arrangements:-(a)MCCB 100 Amps 4 PoleA - 01 No(b)MCCB 63 Amps 4 PoleA - 01 No(c)MCB SPN 6-32 AMP, 10 KA - 02 Nos(d)Aluminium bus bar150 Amp TPN- 01 Set(r) LCD multi function meter - 01 No(f)Indicating lamp set-01 Set of three(g)CT of suitableratio100/5 A- Set of 3 Nos 21 M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. 22 M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth wire of 4 mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Contract Date: Nov 26, 2024 Contract Value : 89.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Feb 22, 2024 Contract Value : 9.67 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
22.
Health and Family Welfare #2309768 AOC
Supply Of Drug And Medicine Under Mndy , 01. Anaesthetics , Bupivacaine Hydochloride In Dextrose Injection Usp Each Ml Contains Bupivacaine Hydrochloride 5.0 Mg Dextrose 80.0 Mg , Bupivacaine Inj Ip 0.5% , Halothane Bp , Isoflurane Usp , Ketamine Inj Ip 50 Mg / Ml , Lignocaine Ointment 5 O / O , Lignocaine And Adrenaline Inj Ip Each Ml. Contains Lignocaine Hydrochloride Ip 20 Mg Adrenaline Ip 0.01 Mg , Lignocaine And Dextrose Injection Ip Each Ml Contains Lignocaine 50 Mg And Dextrose ( Monohydrate ) 75 Mg , Lignocaine Gel Ip 2% , Lignocaine Inj Ip 2% , Propofol Inj Ip / Bp / Usp 10 Mg / Ml , Thiopentone Inj Ip 0.5 G , Sevoflurane , Atropine Sulphate Injection 0.6Mg / Ml , Liquid Medical Oxygen ( Lmo ) , 02. Analgesic Antipyretices And Anti Inflammatory Drugs , Diclofenac Sodium Inj Ip 25 Mg / Ml ( Im / Iv Use ) , Diclofenac Gastro Resistant Tablet Ip 50 Mg ( Enteric Coated ) , Fentanyl Citrate Injection Ip 2 Ml , Ibuprofen And Paracetamol Tablets Ibuprofen 400 Mg+Paracetamol 325 Mg , Ibuprofen Tab Ip 200 Mg ( Coated ) , Ibuprofen Tab Ip 400 Mg ( Coated ) , Morphine Sulphate Inj Ip 10Mg / Ml , Paracetamol Drops Paediatric Paracetamol Oral Suspension Ip ( Each Ml Contains Paracetamol 150Mg ) , Paracetamol Syrup Ip 125 Mg / 5Ml , Paracetamol Tab Ip 500 Mg , Paracetamol Inj. 150 Mg / Ml , Pentazocine Inj Ip 30Mg / Ml ( Im / Iv Use ) , Tramadol Cap Ip 50 Mg , Tramadol Inj 50 Mg / Ml , Indomethacin Cap Ip 25 Mg , Diclofence Prolonged Release Tablet Ip 100 Mg , Ibuprofen Oral Suspension Bp / Usp 100 Mg / 5 Ml , Diclofenac Sod + Paracetamol Tablets Diclofenac Sod 50 Mg + Paracetamol 325 , Aceclofenac And Paracetamol Tablets Aceclofenac 100 Mg And Paracetamol 325 , Diclofenac Gel: Diclofenac Diethylamine 1.16%, Methyl Salicylate 10%, Linseed Oil 3%, Menthol 5% , Etoricoxib Tab Ip 120Mg , Mefenamic Acid Tablets Bp 500 Mg , Fentanyl Citrate Injection 50Mcg / Ml , Naproxen Tablet Ip 500Mg , Naproxen Tablet Ip 250Mg , Etoricoxib Tablet 90 Mg , Aspirin Tablet Ip ( Gastro-Resistant ) 150 Mg , Butorphanol Tartrate Injection Usp 1Mg / Ml 1Ml Size , Diclofenac Sodium Aqueous Injection 75 Mg / Ml 1Ml Size, Iv & Im Use , Paracetamol Infusion Ip1% W / V 100Ml Size , Ketorolac Tablet 10 Mg , Baclofen Tablet Ip 10 Mg ( Each Uncoated Tablet Contains Baclofen Ip 10 Mg ) , Tizanidine Hydrochloride Tablet Ip 2 Mg ( Each Uncoated Tablet Contains Tizanidine Hydrochloride Ip 2 Mg ) , 03. Antiallergics And Drugs Used In Anaphylaxis , Adrenaline Injection Ip 1Mg / Ml Im / Iv Use , Betamethasone Tab Ip 0.5Mg , Chlorpheniramine Maleate Tab Ip 4Mg , Dexamethasone Inj Ip 8Mg / 2Ml , Dexamethasone Tab Ip 0.5 Mg , Hydrocortisone Sodium Succinate Injection Ip 100 Mg Base / Vial ( Im / Iv Use ) , Hydroxyzine Tab Ip 25 Mg , Methyl Prednisolone Sodium Succinate For Injection Usp 500 Mg , Pheniramine Inj Ip 22.75Mg / Ml , Prednisolone Tab Ip 5 Mg , Promethazine Syrup Ip 5 Mg / 5Ml , Promethazine Inj Ip 25Mg / Ml , Promethazine Tab Ip 25 Mg , Betamethasone Sod Phos Inj Ip 4Mg / Ml , Prednisolone Tablet Ip 10 Mg , Prednisolone Tab 20 Mg , Anticold Syrup Each 5 Ml Contains Phenylephrine Hydrochloride 2.5Mg , Chlorpheniramine Maleate 1 Mg, And Paracetamol 125 Mg , Cetirizine, Phenylephrine & Paracetamol Tablets Cetirizine 5 Mg, Phenylephrine 10 Mg & Paracetamol 325 Mg Tab , Cetirizine Syrup Ip 5Mg / 5 Ml , Levoceitrizine Tablet 5Mg , Montelucast ( 10Mg ) + Levocetrizine Tablet ( 5Mg ) , Dexamethasone Tablet Ip 4 Mg ( Each Uncoated Tablet Contains Dexametasone Ip 4 Mg ) , 04. Antidotes And Other Substances Used In Poisoning , Naloxone Inj Ip 0.4Mg / Ml , Pralidoxime Chloride Injection Ip 25 Mg / Ml / 500 Mg , Acetylcystine Solution Usp ( Injection ) 200 Mg / Ml , 05. Anti Epileptic Drugs , Carbamazepine Tab Ip 200 Mg ( Film Coated ) , Carbamazepine Tab Ip 100 Mg ( Film Coated ) , Phenobarbitone Tab Ip 30 Mg , Phenytoin Injection 50Mg / Ml , Phenytoin Oral Suspension Ip 25Mg / Ml , Phenytoin Tab Ip 100 Mg ( Film Coated ) , Sodium Valproate Inj 100 Mg / Ml , Sodium Valproate Gastro Resistant Tablets Ip 200 Mg , Phenobarbitone Inj Ip 200Mg / Ml , Carbamazepine Oral Suspension Usp 100 Mg / 5Ml , Sodium Valproate Oral Solution Ip 200 Mg / 5 Ml , Sodium Valproate Tablet ( Gastro Resistant ) Ip 500Mg , Clobazam Tablet / Capsule 5 Mg , Clobazam Tablet / Capsule 10 Mg , Levetiracetam Tablet 500 Mg , Levetiracetam Oral Suspension 100Mg / Ml , Levetiracetam Injection 500Mg / 5Ml , Gabapentine Tablet / Capsule 100Mg , Gabapentine Tablet / Capsule 300Mg , Lamotrigine Tablet Ip 50 Mg ( Each Sustained Release Tablet Contains Lamotrigine Ip 50 Mg ) , Divalproex Extended Release Tablet Ip 250 Mg ( Each Extended Release Film Coated Tablet Contains Divalproex Sodium Ip Equivalent To Valproic Acid 250 Mg ) , Oxcarbazepine Tablet Ip 150 Mg ( Each Film Coated Tablet Contains Oxcarbazepine Ip 150 Mg ) , Lacosamide Tablet 100 Mg ( Each Film Coated Tablet Contains Lacosamide 100 Mg ) , Topiramate Tablet Ip 25 Mg ( Each Film Coated Tablet Contains Topiramate Ip 25 Mg ) , 06. Anti Infective Drugs , Acyclovir Oral Suspension Ip 400Mg / 5Ml , Acyclovir Tab Ip 200 Mg , Acyclovir Tab Ip 800 Mg , Albendazole Oral Suspension Ip 400 Mg / 10Ml , Albendazole Tablets Ip 400 Mg , Amikacin Inj Ip 100 Mg , Amikacin Inj Ip 500 Mg , Amoxycillin And Cloxacillin Cap 250 + 250 Mg , Amoxycillin And Potassium Clavulanate Tabs Ip 500 Mg + 125 Mg , Amoxycillin Cap Ip 250Mg , Amoxycillin Cap Ip 500Mg , Amoxycillin Dispersible Tablets Ip 125 Mg , Amphotericin B Inj Ip 50 Mg , Ampicillin Injection Ip 500 Mg , Azithromycin Tab 100 Mg Dispersible Tabs ( 3 Tab Strip 10X3x3 ) , Azithromycin Tablets Ip 250Mg , Azithromycin Tab Ip 500 Mg , Benzathine Benzylpenicillin Inj Ip 12 Lac Units , Benzathine Benzylpenicillin Inj Ip 6 Lac Units , Cefixime Tab Ip 100 Mg , Cefixime Tab Ip 200 Mg , Cefoperazone And Sulbactum For Inj ( Cefoperazone Sodium Eq.To Cefoperazone 1Gm And Sulbactum Sodium Eq. To Sulbactum 0.5Gm ) ( Im / Iv Use ) , Cefotaxime Injection 1 G , Cefotaxime Inj Ip 250 Mg , Ceftazidime Inj Ip 1G , Ceftazidime Inj Ip 250 Mg , Ceftazidime Inj Ip 500 Mg , Ceftriaxone Inj Ip 1G / Vial , Ceftriaxone Inj Ip 250 Mg / Vial , Ceftriaxone Inj Ip 500Mg / Vial , Cephalexin Cap Ip 250 Mg , Cephalexin Cap Ip 500 Mg , Chloroquine Phosphate Inj Ip 40 Mg / Ml , Chloroquine Phosphate Tab. Ip 250Mg Eq To 155 Mg Of Chloroquine Base Film , Chloroquine Phosphate Suspension Ip 50 Mg / 5Ml , Ciprofloxacin Injection Ip 200Mg / 100Ml , Ciprofloxacin Tablets Ip 250 Mg Film Coated , Ciprofloxacin Tablet Ip 500 Mg Film Coated , Clotrimazole Cream Ip 2% W / W , Clotrimazole Vaginal Tab Ip 500Mg , Co-Trimoxazole Oral Suspension Ip Each 5 Ml Contains Trimethoprim 40 Mg And Sulphamethoxazole 200 Mg , Co-Trimoxazole Tablets Ip Trimethoprim 40 Mg And Sulphamethoxazole 200 Mg , Diethylcarbamazine Tab Ip 100 Mg , Doxycycline Cap Ip 100 Mg , Fluconazole Tablets Ip 150Mg , Gentamycin Injection Ip 80Mg / 2Ml ( Im / Iv Use ) , Griseofulvin Tab Ip 125 Mg , Itraconazole Cap 100 Mg , Meropenem Inj Ip 500 Mg , Metronidazole Inj Ip 500 Mg / 100Ml , Metronidazole Benzoate Oral Suspension Ip 100 Mg Of Base / 5Ml , Metronidazole Tablets Ip 200 Mg ( Film Coated ) , Metronidazole Tablets Ip 400 Mg ( Film Coated ) , Norfloxacin Tab Ip 400Mg Film Coated , Ofloxacin Tab Ip 200 Mg , Primaquine Tab Ip 2.5 Mg , Primaquine Tab Ip 7.5 Mg , Quinine Dihydrochloride Inj Ip 300 Mg / Ml , Quinine Sulphate Tablets Ip 300 Mg ( Film Coated ) , Ampicillin Cap Ip 500Mg , Nitrofurantoin Tab Ip 100Mg , Cloxacillin Sodium Inj Ip 500Mg , Cephalexin Oral Suspension Ip ( Cephalexin Dry Syrup Ip ) 125Mg / 5 Ml , Ofloxacin Oral Suspension Ip 50Mg / 5Ml , Tinidazole Tab Ip 300 Mg ( Film Coated ) , Tinidazole Tab Ip 500 Mg ( Film Coated ) , Piperacillin + Tazobactum For Injection Usp 4Gm+500Mg , Amoxycillin Oral Suspension Ip ( Dry Syrup ) 125 Mg / 5Ml , Cefpodoxime Dispersible Tab 50 Mg , Cephalexin Tablets 125 Mg ( Dispersible Tablets ) , Meropenem Inj. Ip 1Gm , Acyclovir Intravenous Infusion Ip 250Mg , Acyclovir Intravenous Infusion Ip 500Mg , Amikacin Inj Ip 250 Mg , Amoxicillin And Potassium Clavulanic Ip Inj 600Mg , Amoxicillin And Potassium Clavulanate Inj Ip 1.2Gm , Amoxycillin And Potassium Clavunate Oral Suspension Ip 200 Mg +28.5 Mg / 5 Ml ( 30Ml Bottle ) , Artesunate Injection 60 Mg ( I.M. I.V.Use ) Each Combo Pack Contains Artesunate Injection 60 Mgvial, Sodium Bicarbonate Injection Ip 5 O / O W / V ( 1Ml Ampoule ) , Sodium Chloride Injection Ip 0.9O / O W / V ( 5Ml Ampoule ) , Aztreonam Injection Usp 500 Mg , Cefepime Injection Ip 500 Mg , Cefixime Oral Suspension Ip 25Mg / Ml ( Paediatric Drops ) , Cefuroxime Axetil Tab Ip 250 Mg , Clindamycin Capsule Ip 150Mg , Clindamycin Capsule Ip 300 Mg , Levofloxacin Tablets Ip 250 Mg , Linezolid Tablets Ip 600 Mg , Linezolid Inj 200Mg / 100Ml , Mefloquine Tablets Ip 250 Mg , Ofloxacin And Ornidazole Tablets Ofloxacin 200 Mg And Ornidazole 500 Mg , Ofloxacin Infusion Ip 200Mg / 100 Ml ( In Nacl Inj ) , Vancomycin For Intravenous Infusion Ip 500 Mg , Vancomycin For Intravenous Infusion Ip 1 Gm , Artemether And Leumefantrine Tablet ( 80 Mg And 480 Mg ) , Co-Trimoxazole Tablet ( Trimethoprim 160Mg+Sulphamethoxazole 800Mg ) , Aztreonam Injection 1Gm , Framycetin Sulphate Cream 1 O / O 30Gm Pack , Framycetin Sulphate Cream 1 O / O 100 Gm Pack , Artemether And Leumefantrine Tablet ( 40 Mg And 240 Mg ) , Amoxycillin Tablet 250 Mg + Calvulanic Acid 125 Mg Ip Each Film Coated Tab Conatin Amoxycillin Trihydrate Ip 250 Mg & Potassium Clavulanate Ip 125 Mg , Piperacillin Injection 2 Gm + Tazobactom 250 Mg Ip , Ceftriaxone Injection 1 Gm + Tazobactum 1.25 Mg , Cefadraxil Tablet 250 Mg , Cefadraxil Tablet 500 Mg , Ofloxacin Oral Suspension Ip ( Each 5Ml Contains Ofloxacin Ip 100 Mg ) 30 Ml Size , Levofloxacin Tablets Ip 500 Mg ( Each Film Coated Tablet Contains Levofloxacin Hemihydrate Ip 500 Mg ) , Faropenem Tablet Sodium 200 Mg ( Each Film Tablet Contains Faropenem Sodium Equivalent To Faropenem Sodium 200 Mg ) , Clindamycin Phosphate Injection Ip 300 Mg , Imipenem + Cilaatatin Injection 500Mg / 500Mg Ip Powder For Solution , Polymixin Sulphate B Injection Usp 5 Lac I.U. , Meropenem Injection Ip 250 Mg , Colistimethate Injection Ip 1M Iu Powder For Solution , Voriconazole Injection 200 Mg / Vial , Terbinafine Hydrochloride Tablet 250 Mg , Valganciclovir Tablet 450 Mg , Entecavir Tablet Ip 0.5 Mg ( Each Film Coated Tablet Conatins Entecavir Ip 0.5 Mg ) , Ganciclovir Sodium Injection 500 Mg ( Lyophilized Powder For Reconstitution ) , 07. Anti Neoplastic And Immuno Suppressant Drugs Palliative Care , Azathioprine Tab Ip 50 Mg , Bleomycin Injection Ip 15Mg ( Bleomycin Sulphate Injection 15 Units ) , Chlorambucil Tab Ip 5 Mg , Cisplatin Inj Ip 50 Mg / 50 Ml , Cyclophosphamide Inj Ip 200 Mg , Cyclophosphamide Inj Ip 500 Mg , Cytarabine Injection Bp 500Mg , Danazol Cap Ip 50 Mg , Daunorubicin Inj Ip 20 Mg , Doxorubicin Inj Ip 50 Mg / 25 Ml , Etoposide Inj Ip 100 Mg , Fluorouracil Inj Ip 250 Mg / 5Ml , L-Asparaginase Inj 10000 Iu , Leucovorin Calcium Inj Ip / Calcium Folinate Inj Ip 10 Mg / Ml , Melphalan Tab Ip 5 Mg , Mercaptopurine Tab Ip 50 Mg , Methotrexate Inj Ip 50 Mg / 2 Ml , Methotrexate Tab Ip 2.5 Mg , Paclitaxel Inj Ip 260 Mg , Paclitaxel Inj Ip 100 Mg , Tamoxifen Tab Ip 10 Mg , Vinblastine Inj Ip 10Mg / 10Ml , Vincristine Inj Ip 1Mg ( Vial ) / Vincristin Injection Usp 1Mg / Ml ( Amp ) , Alpha Interferon Injection Interferon Alpha 2 Concentrated Solution Ip 3 Million Unit , Carboplatin Injection 150 Mg , Carboplatin Injection 450 Mg , Cisplatin Inj Ip 10 Mg / 10 Ml , Dacarbazine Injection 500 Mg Usp / Bp , Filgrastim Injection ( Granulocyte Colony Stimulating Factor ) ( Sc / Iv Use ) 300 Mcg , Gemcitabine For Injection 200 Mg , Gemcitabine For Injection 1Gm , Ifosfamide Injection Ip / Bp / Usp 1Gm , Imatinib Tab 400Mg , Methotrexate Tablets Ip 10 Mg , Mitomycine Injection Ip 10 Mg / Mitomycine For Injection Usp 10 Mg , Oxaliplatin Injection Usp 50 Mg , Cyclosporin Capsule Usp / Ip 50 Mg , Procarbazine Hydrochloride Capsule Usp 50 Mg ( Each Capsule Contains Procarbazine Hydrochloride Usp 50 Mg ) , Bendamustine Injection 100 Mg , Capecitabine Tablet Ip 500 Mg ( Each Film Coated Tablet Contains Capecitabine Ip 500 Mg ) , Letrozole Tablet Ip 2.5 Mg ( Each Film Coated Tablet Contains Letrozole Ip 2.5 Mg ) , Temozolomide Capsule Ip 100 Mg ( Each Hard Gelatin Capsule Contains Temozolomide Ip 100 Mg ) , Bortezomib Injection 2Mg , Abiraterone Acetate Tablet Ip 250 Mg ( Each Uncoated Tablet Contains Abiraterone Acetate Ip 250 Mg ) , Lomustine Capsule Ip 40 Mg ( Each Capsule Contains Lomustine Ip 40 Mg ) , Thalidomide Capsule Usp 100 Mg ( Each Hard Gelatin Capsule Contains Thalidomide Usp 100 Mg ) , Bevacizumab Injection 400 Mg , Bevacizumab Injection 100 Mg , Cyclophosphamide Tablet Ip 50 Mg ( Each Sugar Coated Tablet Contains Cyclophosphamide Ip 53.5 Mg Equivalent To Anhydrous Cyclophosphamide 50 Mg ) , Gefitinib Tablet Ip 250 Mg ( Each Film Coated Tablet Contains Gefitinib Ip 250 Mg ) , Mycophenolate Mofetil Capsule Ip 250 Mg ( Each Capsule Conatin Mycophenolate Mofetil Ip 250 Mg ) , Tacrolimus Capsule Ip 0.5 Mg ( Each Hard Gealtin Capsule Tacrolimus Ip 0.5 Mg ) , Mycophenolate Sodium Tablet 360 Mg ( Each Enteric Coated Tablet Conatin Mycophenolate Sodium 360 Mg ) , Bicalutamide Tablet Ip 50 Mg ( Each Film Tablet Contains Bicalutamide Ip 50 Mg ) , 6 Thioguanine Tablet Usp 40 Mg ( Each Uncoated Tablet Contains 6 Thioguanine Usp 40 Mg ) , Zoledronic Acid Injection Ip 4Mg / 100Ml 100 Ml Size , Dasatinib Tab 100 Mg , 08. Anti Parkinsonism Drugs , Levodopa And Carbidopa Tablets Ip Levodopa 100 Mg + Carbidopa 10 Mg , Levodopa And Carbidopa Tab 250 Mg+ 25 Mg , Trihexyphenidyl Hcl Tab Ip 2 Mg , Bromocriptine Tablets Ip 2.5 Mg , 09. Drugs Affecting The Blood , Acenocoumarol Tab Ip / Nicoumalone Tab Ip 2 Mg , Deferasirox Tab 100 Mg , Deferasirox Tab 500 Mg , Deferiprone Cap 250 Mg , Deferiprone Cap 500 Mg , Desferrioxamine Injection Ip 500 Mg / Vial ( For I.M. Inj And I.V S.C. Infusion ) , Dried Human Anti Haemophlic Fraction Ip ( Dried Factor Viii Fraction Ip ) 250 Iu / Vial ( Iv Use ) , Enoxaparin Sodium Inj Ip 60 Mg , Ethamsylate Inj 250 Mg / 2Ml ( Im / Iv ) , Heparin Sodium Inj Ip 5000 Iu / Ml ( Im / Iv Use ) , Human Albumin Solution Ip 20% , Rh-Erythropoetin Inj 10000 Iu , Rh-Erythropoetin Inj 2000Iu , Rh-Erythropoetin Inj 4000 Iu , Vitamin K Injection Each Ml Contains Menadione Sodium Bisulphite 10Mg Equivalent To 5.2 Mg Of Menadione. ( Aqueous Solution ) , Polygeline 3.5% Solution With Electrolytes For I.V. Infusion , Factor Ix Concentrate ( Purified ) 600 I.U. ( Human Coagulation Factor Ix ) , Anti Inhibitor Coagulation Complex ( Human Plasma Protein With A Factor Viii Inhibitor Bypassing Activity Of 500 I.U. Per Vial ) , Hydroxyethyl Starch ( 130 / 0.4 ) 6 O / O W / V With Sodium Chloride 0.9 O / O W / V Intravenous Infusion / Balanced Electrolyte Solution Of Sodium Chloride, Sodium Acetate, Potassium Chloride, Magnesium Chloride Intravenous Infusion , Tranexamic Acid Tablets Ip / Bp 500 Mg , Warfarin Sodium. Tab Ip 5Mg , Vitamin K-1 ( Phytomenadione ) 1Mg / 0.5Ml Injection ( Detail In Rc ) , Dried Factor Viii Fraction Ip ( Iv Use ) 500 Iu / Vial , Dried Factor Viii Fraction Ip ( Iv Use ) 1000 Iu / Vial , Recombinant Coagulation Factor Viia 1Mg , Recombinant Coagulation Factor Viia 2Mg , N Butyl Alcohol Injection 0.26Mg / 5Ml, Citric Acid 2.5Mg / 5Ml And Sod. Chloride Solution 5 Ml Size , Ethamsylate Tablet 500 Mg ( Each Uncoated Coated Tablet Contains Ethamsylate 500 Mg ) , Feracrylum 1% W / W Sterile Solution 100 Ml , Tranexamic Acid Injection Ip 100Mg / Ml 5Ml Size , Recombinant F Ix 500 Iu With Diluent , 3Rd Generation Recombinant F Viii 250 Iu With Diluent , 3Rd Generation Recombinant F Viii 1000 Iu With Diluent , 10. Cardio Vascular Drugs , Amiodarone Tab Ip 100 Mg , Amiodarone Tab Ip 200 Mg , Amiodarone Hydrochloride Inj 50 Mg / Ml , Amlodipine Tab Ip 2.5 Mg , Amlodipine Tablets Ip 5 Mg , Atenolol Tab Ip 50 Mg , Atorvastatin Tab Ip 10Mg , Clopidogrel Tab Ip 75 Mg , Digoxin Inj Ip 0.25 Mg / Ml , Digoxin Tab Ip 0.25 Mg. , Diltiazem Tabs Ip 30 Mg Film Coated , Dobutamine Inj Ip / Bp 50Mg / Ml / 250Mg ( Vial / ) Dobutamine Inj Usp250 Mg / 5Ml ( Amp ) , Dopamine Hydrochloride Inj 40 Mg / Ml , Enalapril Maleate Tab Ip 5Mg , Enalapril Maleate Tab Ip 2.5Mg , Isosorbide Dinitrate Tab Ip 5 Mg , Isosorbide Mononitrate Tabs Ip 20 Mg , Lisinopril Tab Ip 5 Mg , Losartan Tab Ip 50 Mg , Magnesium Sulphate Inj. 500Mg / Ml ( 50%W / V ) , Methyldopa Tab Ip 250Mg Film Coated , Nifedipine Cap Ip 5Mg , Nifedipine Tablets Ip 10 Mg ( Sustained Release ) , Nitroglycerin Inj 5 Mg / Ml , Propranolol Tab Ip 40 Mg , Streptokinase Injection 15 Lac Units , Verapamil Tab Ip 40 Mg Film Coated , Labetalol Tab Ip 100Mg , Labetalol Hcl Inj Ip 20Mg / 4Ml , Aspirin Delayed Release Tablet / Aspirin Gastroresistant Tab ( Each Enteric Coated Tablet Contains Acetyl Salicylic Acid 75 Mg ) , Amlodipine And Enalapril Maleate Tablets ( Amlodipine Besilate Equivalent To Amlodipine 5 Mg, Enalapril Maleate 5 Mg ) , Losartan Potassium And Amlodipine Tablets Ip ( Losartan Potassium 50 Mg, Amlodipine Besilate Eq To Amlopdipine 5Mg ) , Losartan Potassium And Hydrochlorothiazide Tablets Ip ( Losartan Potassium 50 Mg, Hydochlorothiazide 12.5 Mg ) , Amlodipine And Lisinopril Tablets Amlodipine Besilate Equivalent To Amlodipine 5 Mg, Lisinopril Eq To Lisinopril ( Anhydrous ) 5 Mg , Amlodipine And Atenolol Tablet ( Amlodipine Besilate Equivalent To Amlodipine 5Mg, Atenolol 50Mg ) , Atenolol Tab Ip 25 Mg , Enalapril Maleate Tablets Ip 10 Mg , Lisinopril Tablets Ip 10 Mg , Lisinopril Tab Ip 2.5 Mg , Losartan Tab Ip 25 Mg , Adenosine Injection 6 Mg / 2Ml , Atorvastatin Tablets Ip 40 Mg , Clopidogrel And Aspirin Tables, Clopidogrel 75 Mg And Aspirin 75 Mg , Fenofibrate Capsules / Tab Ip 200 Mg , Isoprenaline Injection Ip 2Mg / Ml , Metoprolol Tablets Ip 25 Mg , Metoprolol Succinate Extended Release Tablets Ip / Usp 50 Mg , Noradrenaline Injection Ip 2 Mg / Ml , Prazosin Tablets ( Extended Release ) 2.5 Mg , Telmisartan Tablets Ip 40 Mg , Urokinase Injection 5 Lac Unit ( Lyophilized ) , Ramipril Tablets Ip 2.5 Mg , Glyceryl Trinitrate Tablets 2.6 Mg Controlled Release Tablets , Clonidine Hydrochloride Tablet Ip 0.1 Mg ( Each Tablet Contains Clonidine Hydrochloride Ip 0.1 Mg ) , Sotalol Hydrochloride Tablet Usp / Bp 40 Mg ( Each Film Coated Tablet Contains Sotalol Hydrochloride Usp / Bp 40 Mg ) , Esmolol Hydrochloride Injection 10Mg / Ml 10 Ml Size , Sodium Nitroprusside Injection 25 Mg / Ml 2Ml Size , Carvedilol Tablet 3.125 Mg , Rosuvastatin Tablet Ip 20 Mg ( Each Film Coated Tablet Contains Rosuvastatin Calcium Ip Equivalent To Rosuvastatin 20 Mg ) , Rosuvastatin Tablet10 Mg , Sacubitril 24 Mg And Valsartan 26 Mg Tablet , 11. Dental Drugs , Chlorhexidine Mouthwash Ip / Bp 0.2 O / O , Dental Gel Choline Salicylate 8.7 O / O, Benzalkonium Chloride 0.01 O / O, Lignocaine Hcl 2 O / O ( Flavoured Gel Base ) , Tooth Gel Sodium Monofluorophosphate 0.7 O / O And Potassium Nitrate 5 O / O ( In Flavoured Base ) , Gum Paint Containing Tannic Acid 2%, Cetrimide 0.1%, Zinc Chloride 1% , Metronidazole 1% And Chlorhexidine Gluconade 0.25% Gel , 12. Dermatological Drugs , Compound Benzoic Acid Ointment Ip Benzoic Acid 6 O / O + Salicylic Acid 3 O / O , Acyclovir Cream 5% , Cetrimide Cream Ip 15 Gm , Fusidic Acid Cream Ip 2% , Glycerin Ip 400 Gm , Liquid Paraffin Ip 400 Ml , Miconazole Nitrate Cream Ip 2% , Povidone Iodine Ointment 5% 15 Gm , Neomycin Bacitracin And Sulphacetamide Power ( Neomycin 5 Mg, Bacitracin 250 Units, Sulphacetamide 60 Mg ) , Silver Sulphadiazine Cream Ip 1% 50Gm Tube , Gentian Violet Topical Solution Usp 1O / O , Clotrimazole Mouth Paint ( Clotrimazole 1 O / O W / V ) , Beclomethasone, Neomycin And Clotrimazole Cream ( Beclomethasone Dipropionate 0.025 %, Neomycin Sulphate 0.5 % And Clotrimazole 1 % ) , Gamma Benzene Hexachloride Lotion 1% ( Lindane Lotion Usp ) , Betamethasone Dipropionate Cream Ip 0.05% , Betamethasone Lotion Ip 0.05 O / O , Clindamycin Phosphate Gel Usp 1 O / O , Clobetasol Propionate Cream 0.05 O / O , Glycerin Ip 100 Ml , Ketoconazole Cream 2% , Permethrin Lotion 5% , Permethrin Cream 5% , Tretenoin Cream Usp 0.025% , Coal Tar 6% & Salicylic Acid 3% Ointment , Calamine Lotion Ip 100Ml , Powder Clotrimazole 1% W / W 30 Gm , Terbinafine Cream 1% W / W ( 10Gm Tube ) , Olopatadine Hydrochloride Ophthalmic Solution 0.1 , Oitment Mupirocin Ip 2% , 13. Reagents And Diagnostic Agents , Multi Stix Test Strip , Anti A Blood Grouping Serum Ip ( Anti A Monoclonal Serum ) , Anti B Blood Grouping Serum Ip ( Anti B Mono Clonal Serum ) , Anti D ( Rh ) Blood Grouping Serum Ip / Anti D Blood Grouping Serum Ip , Diatrizoate Meglumine & Diatrizoate Sodium Inj Usp 60% ( Iodine Conc.= 292 Mg / Ml ) , Diatrizoate Meglumine And Diat Sod Inj Usp 76%W / V ( Iodine = 370 Mg / Ml ) , Gadodiamide Inj. 0.5Mml / Ml Vial , Vdrl Antigen ( With + Ve And - Ve Control ) / Rpr Slide Kit , Iohexol Usp ( Solution For Injection ) Non Ionic Contrast Medium In Sterile Aquous Solution 300 Mg Iodine / Ml , Iohexol Usp ( Solution For Injection ) Non Ionic Contrast Medium In Sterile Aqueous Solution 350 Mg Iodine / Ml. , 14. Disinfectants And Antiseptics , Povidone Iodine Solution Ip 5 % 500 Ml , Compound Benzoin Tincture Ip , Formaldehyde Solution ( 34.5 Per. - 38 Per. ) , Gluteraldehyde Solution 2% , Hydrogen Peroxide Solution Ip 6 O / O ( 20 Vol ) , Lysol ( Cresol With Soap Solution ) Ip ( Cresol 50 O / O + Soap 50 O / O ) , Povidone Iodine Scrub Solution / Cleansing Solution 7.5 O / O W / V Povidone Iodine ( Suitable For Hand Wash ) , Surgical Spirit Ip / Bp ( 500 Ml ) , Chlorhexidine Gluconate Solution 5% 250 Ml , Surgical Spirit Ip / Bp ( 100 Ml ) , Povidone Iodine Solution Ip 5% 100Ml Bottle , Povidone Iodine Ointment Usp 250 Gm , Povidone Iodine Solution Ip 10 % , Silver Sulphadiazine Cream Ip 1% 500 Gm Jar , 15. Diuretics , Acetazolamide Tab Ip 250Mg , Frusemide Tab Ip 40 Mg , Furosemide Injection Ip 10Mg / Ml ( Im And Iv Use ) , Hydrochlorthiazide Tab Ip 12.5 Mg , Mannitol Inj Ip 20% W / V , Spironolactone Tab Ip 25Mg , Torsemide Tab 10 Mg , Hydrochlorthiazide Tab Ip 25Mg , Torsemide Inj 10 Mg / Ml , Spironolactone Tablets Ip 50 Mg , 16. Drugs For Ear Ailments , Ciprofloxacin 0.3 O / O And Dexamethasone 0.1 O / O Ear Drops Ciprofloxacin And Dexamethasone Otic Suspension Usp , Clotrimazole 1 O / O With Beclomethasone Dipropionate 0.025 O / O Ear Drops , Neomycin, Polymixin B And Hydrocortisone Ear Drops Neomycin Sulphate 3400 Iu, Polymixin B Sulphate 10000 Iu, And Hydrocortisone 10 Mg Per Ml Neomycin And Polymixin B Sulfate And Hydrocortisone Otic Solution Usp , Ceruminolytic Drops ( Wax Dissolving Ear Drops ) Paradichlorobenzene 2 O / O , Benzocaine 2.7 O / O , Chlorbutol 5 O / O, Turpentine Oil 15 O / O , 17. Gastro Intestinal Drugs , Drotaverine Hydrochloride Inj 40 Mg / 2 Ml , Ointment Containing Lidocaine Ip 3 O / O Zinc Oxide Ip 5 O / O , Hydrocortisone Ip 0.25 O / O, Allantoin Ip 0.5 O / O , Antacid Tablets.Formula, Each Chewable Tablet Contains Magnesium Trisilicate 250 Mg, Dried Aluminium Hydroxide Gel 120 Mg, Peppermint Oil , Antacid Liquid, Each 5Ml Contains Dried Aluminium Hydroxide Gel 250 Mg, Magnesium Hydroxide 250Mg, Activated Polydimethyl Siloxane 50Mg , Bisacodyl Tab Ip 5 Mg , Dicyclomine Tab Ip 10 Mg , Dicyclomine Inj Ip 10 Mg / Ml , Dicyclomine Hydrochloride Oral Solution Ip 10Mg / 5Ml , Domperidone Suspension Ip 5Mg / 5Ml , Domperidone Tab Ip 10 Mg , Hyoscine Butylbromide Inj Ip 20 Mg / Ml , Loperamide Tab Ip 2 Mg , Metoclopramide Inj Ip 10Mg / 2Ml , Metoclopramide Tab Ip 10 Mg , Omeprazole Cap Ip 20 Mg , Ondansetron Inj Ip 2Mg / Ml , Ors Powder Ip , Pentoprazole Inj 40 Mg , Ranitidine Hcl Injection Ip 50Mg / 2Ml , Ranitidine Tab Ip 150Mg Film Coated , Sodium Phosphates Enema Bp Each 100Ml Contains Sodium Dihydrogen Phosphate Dihydrate 10 O / O Disodium Hydrogen Phosphate Dodecahydrate 8 O / O , Hyoscine Butyl Bromide Tablets Ip 10Mg , Drotaverine Tab Ip 40 Mg , Ranitidine Tab Ip 300Mg Film Coated , Dicyclomine Hydrochloride And Activated Dimethicone Suspension Each Ml Contains Dicyclomine Hydrochloride 10Mg Activated Dimethicone 40Mg , Dicyclomine And Paracetamol Tablets Dicyclomine Hydrochloride 20 Mg + Paracetamol 325 Mg Tablets , Metoclopramide Hydrochloride Syrup Ip 5 Mg / 5Ml , Domperidone Oral Drops 10Mg / Ml ( 10Ml ) , Drotaverine And Mefenamic Acid Tablets Drotaverine 80 Mg And Mefenamic Acid 250 Mg , Lactic Acid Bacillus Tab 60 Million Spores , Lactulose Solution Usp / Bp 10Gm / 15Ml Or 3.35 Gm / 5Ml , Liquid Paraffin Ip 100 Ml , Ondansetron Orally Disintegrating Tablets Ip 4Mg , Pantoprazole 40Mg And Domperidone 30Mg Sr Cap Pantoprazole As Enteric Coated Pellets And Domperidone As Sr Pellets , Ursodeoxycholic Acid Tablets 300 Mg , Doxylamine Succinate 20 Mg & Pyridoxine Hydrochloride 20 Mg Tablet ( Each Enteric Coated Tablet Contains Doxylamine Succinate Usp 20 Mg & Pyridoxine Hydrochloride Ip 20 Mg ) , Prochlorperazine Mesylate Injection 12.5Mg / Ml 5Ml Size , Probiotic Sachets 1 Gm Size ( Each Gram Sachet Contains Saccharomyces Boulardii 250Mg & Lactic Acid Bacillus 150 Million Spores ) , Mesalamine Tablet Usp 1.2 Gm Enteric Coated ( Each Enteric Coated Prolonged Release Tablet Conatin Mesalamine Usp 1.2 Gm ) , 18. Gout And Rheumatiod Arthritis , Allopurinol Tablets Ip 100 Mg , Hydroxychloroquine Sulphate Tablets 200Mg , Leflunomide Tablets Ip / Usp 10Mg ( Film Coated ) , Leflunomide Tablets Ip / Usp 20Mg ( Film Coated ) , Sulfasalazine Delayed Release Tablets Usp / Gastroresistant Sulfasalazine Tablets Bp 500 Mg , 19. Hormones Other Endocrine Drugs And Contraceptives , Biphasic Isophane Insulin Inj Ip ( 30 % Soluble Insulin And 70 % Isophane Insulin ) Inj. 40 Iu / Ml ( R-Dna Origin ) , Carbimazole Tabs Ip 5 Mg ( Film Coated ) , Carboprost Tromethamine Injection Each Ml Contains Carboprost 0.25 Mg / Ml , Clomifene Tab Ip 25 Mg , Clomiphene Tab Ip 50 Mg , Conjugated Estrogen Tabs Usp 0.625 Mg. , Dinoprostone Cream / Gel 0.5 Mg Dinoprostone In Syringe , Ethinyloestradiol Tabs Ip 50 Mcg , Glibenclamide Tab Ip 5 Mg , Gliclazide Tab Ip 40 Mg , Glimepiride Tab Ip 2 Mg , Glimepiride Tab Ip 1Mg , Glipizide Tab Ip 5Mg , Hydroxyprogesterone Inj Ip 250Mg / Ml , Isophane Insulin Inj Ip 40 Iu / Ml , Metformin Tab Ip 500 Mg ( Film Coated ) , Norethisterone Tab Ip 5 Mg , Pioglitazone Tab Ip 15 Mg , Progesterone Inj 200 Mg / 2Ml , Insulin Injection Ip ( Soluble Insulin / Neutral Insulin Injection ) 40 Iu / Ml ( R.Dna Origin ) , Thyroxine Sodium Tablets Ip 100Mcg , Metformin Hydrochloride ( Sustained Release Tablets Ip 1000 Mg , Glipizide And Metformin Hydrochloride Tablets Usp ( Glipizide 5 Mg, Metformin Hydrochloride 500 Mg ) , Glibenclamide And Metformin Hydrochloride ( Sr ) Tablets Glibenclamide 5 Mg, Metformin Hydrochloride 500 Mg ( Sustained Release ) , Metformin Hcl ( Sustained Release ) And Glimepiride Tab Metformin Hcl ( Sustained Release ) 500Mg , Glimepiride 1Mg , Metformin Hydrochloride ( Sustained Release ) And Glimepiride Tablets ( Metformin Hydrochloride ( Sustained Release ) 500 Mg, Glimipiride 2Mg ) , Glimepiride, Pioglitazone And Metformin Hydrochloride ( Sustained Release ) Tablets Each Tablet Contains Glimepiride 2Mg, Pioglitazone 15 Mg, Metformin Hydrochloride ( Sustained Release ) 500 Mg , Gliclazide And Metformin Tablets ( Gliclazide 80 Mg And Metformin Hcl 500 , Glucagon For Injection Usp 1 Mg / Ml , Medroxyprogesterone Acetate Tablets Ip 10 Mg , Thyroxine Tablets Ip 50 Mcg , Octreotide Injection 50 Mcg / Ml , Insulin Glargine 3Ml ( 100Iu / Ml ) With 15 Insulin Syringes And Needles / Cartridge 3Ml ( 100Iu / Ml ) With 15 Needles And 1 Pen Per 20 Cartridges , Tenaligliptin Tablet 20Mg , Insulin Glargine 10 Ml Vial ( 100 Iu / Ml ) With 30 Insuline Syringes With Needle , 20. Immunologicals , Human Anti D Immunoglobulin Injection 300Mcg ( Im Use ) , Human Anti D Immunoglobulin 150 Mcg , Human Rabies Immunoglobulin Inj 150 Iu / Ml , Rabies Vaccine Human ( Cell Culture ) Ip ( Intradermal ) 2.5 Iu , Rabies Vaccine Human ( Cell Culture ) Ip ( Intramuscular ) 2.5 Iu / Dose , Snake Venum Anti Serum Ip ( Lyophilized ) Polyvalent Anti Snake Venum, Serum Enzyme Refined.Contain Purified Equine Globulins.1 Ml Of Serum Neutralizes 0.6 Mg Of Cobra Venum, 0.45 Mg Of Common Kraite ( Bungaras ) Venum ( Details In Rc ) , Tetanus Immunoglobulin 250 Iu / Vial , Tetanus Vaccine ( Adsorbed ) Ip 5 Ml Vial , Rabies Antiserum Ip ( Equine ) 300 Units Per Ml Contains Equine Anti-Rabies Immunoglobulin Fragments ( I.M. / Sc Use ) , Diphtheria Antitoxin 10000 Iu , Hepatitis B Immunologlobin Injection Ip 200 I.U , Human Immunoglbulin Ing With 12% Lgm, 12%Lga , 76%Lgg In Pack Of 10 Ml ( 0.5Mg ) , 21. Muscle Relaxants And Cholinestrase Inhibitors , Atracurium Inj 10 Mg / Ml , Glycopyrrolate Inj Usp 0.2 Mg / Ml , Midazolam Inj Ip 1 Mg / Ml , Neostigmine Inj Ip 0.5 Mg / Ml , Neostigmine Tab Ip 15 Mg , Succinylcholine Inj. Ip 50 Mg / Ml ( Iv Use ) , Valethamate Bromide Inj 8Mg / Ml , Vecuronium Bromide For Injection 4Mg ( Freeze Dried ) , Chlorzoxazone , Diclofenac Sodium & Paracetamol Tablets ( Chlorzoxazone 250Mg , Diclofenac Sodium 50Mg Paracetamol 325 Mg ) , Neostigmine Injection Ip 2.5Mg / 5Ml , Cis Atracurium Besylate Injection 2 Mg / Ml In 5 Ml Vial , 22. Opthamological Preparations , Tropicamide Eye Drop Ip 1O / O , Atropine Eye Ointment Ip 1% , Atropine Sulphate Ophthalmic Solution Usp 1% , Chloramphenicol Eye Drops Ip 0.5 0 / 0 , Ciprofloxacin Eye Drops 0.3 O / O W / V , Ciprofloxacin Ophthalmic Ointment Usp 0.3% , Hydroxypropylmethyl Cellulose Solution 20 Mg / Ml , Tobramycin And Dexamethasone Ophthalmic Suspension Usp 0.3 O / O +0.1 O / O , Tobramycin Eye Drops 0.3% [ 331 ] , Tobramycin Ophthalmic Ointment Usp 0.3% , Flurbiprofen Sodium Ophthalmic Solution Ip 0.03 O / O W / V , Hyaluronidase Injection Ip Each Vial Contains Hyaluronidase Ip 1500 I.U. , Lidocaine Hcl Topical Solution Usp 4% , Fluconazole Eye Drops 0.3% , Timolol Eye Drops Ip 0.5 O / O W / V , Homatropine Eye Drops Ip 2% , Travoprost Eye Drops Ip 0.004 O / O , Brimonidine Tartrate & Timolol Maleate Eye Drops 0.15% + 0.5% , Betaxolol Eye Drops 0.5 O / O , Carboxymethylcellulose Eye Drops 0.5% , Phenylephrine Hydrochloride Opthalmic Solution Usp / Phenylephrine Eye Drops Bp 5% , Acyclovir Eye Ointment Ip 3% W / W 5Gm Size , Eye Drop Moxifloxacin 0.5% W / V Ophthalmic Solution Ip 5Ml Size , Chloramphenicol 1% W / W Eye Ointment Ip, 3Gm Size , 23. Oxytocics And Antioxytocics , Isoxsuprine Inj Ip 5 Mg / Ml , Isoxsuprine Tab Ip 20 Mg , Methylergometrine Inj Ip 0.2 Mg / Ml , Methylergometrine Tab Ip 0.125 Mg , Misoprostol Tab Ip 200 Mcg , Oxytocin Inj Ip 5 Iu / Ml , Mifepristone Tab Ip 200Mg , Natural Micronised Progesteron Soft Gelatin Capsule 200 Mg ( Each Soft Gelatin Capsule Contains Progesteron Ip 200 Mg ) , Cabergoline Tablet Ip 0.5Mg ( Each Uncoated Coated Tablet Contains Cabergoline Ip 0.5Mg ) , Human Chorionic Gonadotropin Injection Ip 5000 I.U. , Leurprolide Acetate Depot 3.75 Mg , Leurprolide Acetate Depot 11.25 Mg , 24. Psychotropic Drugs , Alprazolam Tab Ip 0.25 Mg , Alprazolam Tab Ip 0.5Mg , Amitriptyline Tab Ip 25Mg Film Coated , Chlordiazepoxide Tablets Ip 10Mg , Chlorpromazine Tablets Ip 100 Mg ( Coated Tablet ) , Chlorpromazine Tablets Ip 25 Mg ( Sugar Coated ) , Chlorpromazine Tablets Ip 50 Mg ( Coated Tablets ) , Chlorpromazine Inj. Ip 25Mg / Ml , Diazepam Inj Ip 10Mg / 2Ml ( 1M / Iv Use ) , Diazepam Tab Ip 5 Mg , Escitalopram Tab Ip 10 Mg , Fluoxetine Cap Ip 20 Mg , Haloperidol Inj Ip 5 Mg / Ml , Haloperidol Tab Ip 1.5 Mg , Haloperidol Tab Ip 5 Mg , Imipramine Tab Ip 25 Mg ( Coated Tab ) , Imipramine Tab Ip 75 Mg ( Coated ) , Lithium Carbonate Tab Ip 300 Mg , Lorazepam Inj 2 Mg / Ml , Olanzapine Tab Ip 5 Mg , Risperidone Tab 2Mg , Risperidone Tab 1 Mg , Sertraline Tab 50 Mg , Trifluperazine Tab Ip 5 Mg Coated , Quetiapine Tablet Ip 50Mg , Quetiapine Tablet Ip 25Mg , Clonazepam Tablet 0.5 Mg , Levosulpiride Tablet 25 Mg ( Each Uncoated Tablet Contains Levosulpiride 25 Mg ) , Lorazepam Tablet Ip 2 Mg ( Each Uncoated Tablet Contains Lorazepam Ip 2 Mg ) , Zolpidem Tablet 5 Mg , 25. Drugs Acting On The Respiratory Tract , Aminophylline Inj Ip 25 Mg / Ml , Beclomethasone Inhalation Ip 200 Mcg / Dose , Budesonide Nebulizer Suspension 0.25Mg / Ml , Cough Syrup Each 5 Ml Contains Chloropheniramine Maleate Ip 3 Mg, Ammonium Chloride 130 Mg, Sodium Citrate 65 Mg, Menthol 0.5 Mg, Syrup Q.S. , Ipratropium Bromide Nebulizer Solution 250 Mcg / Ml , Salbutamol Tablet Ip 4 Mg , Salbutamol Inhalation 100 Mcg / Dose , Salbutamol Nebuliser Solution Bp 5 Mg / Ml , Salbutamol Tab Ip 2 Mg , Theophylline And Etofylline Injection ( Anhydrous Theophylline 50.6Mg + Etofylline 169.4 Mg ) , Theophylline And Etofylline Tablets ( Theophylline Ip 23Mg + Etofylline 77 Mg ) , Theophylline Tablet 400Mg Sustained Release / Controlled Release ( Theophylline Prolonged Released Tablet Ip ) , Salbutamol Syrup Ip 2Mg / 5Ml , Dextromethorphan Hbr Syrup Ip 13.5Mg / 5Ml , Saline Nasal Solution ( Drops ) ( Sodium Chloride 0.65 O / O ) , Formoterol Fumerate & Budesonide Powder For Inhalation Ip 6 Mcg + 200 Mcg , Budesonide Powder For Inhalation 200 Mcg , Ipratropium Powder For Inhalation Ip 40 Mcg , Terbutaline Tablets Ip 2.5 Mg , Xylometazoline Nasal Drops Ip 0.1% , Cough Syrup / Expectorant ( 50 ) Ml , Acebrophylline Tablet 100 Mg , 26. Solution Correcting Water Electrolyte And Acid Base Disturbance , Compound Sodium Lactate Inj. Ip , Dextrose Inj Ip 25% W / V , Dextrose Inj Ip 10% , Dextrose Inj Ip 5% , Multiple Electrolytes And Dextrose Injection Type I Ip ( Electrolyte P Injection , Multiple Electrolytes And Dextrose Injection Type Iii Ip Electroylte M Injection ( I.V. ) , Potassium Chloride Inj. 0.15 Gm / Ml , Potassium Chloride Oral Solution U.S.P 500Mg / 5Ml , Sodium Chloride And Dextrose Injection Ip 0.9 O / O + 5 O / O , Sodium Chloride Inj Ip 500 Ml , Sodium Chloride Injection Ip 100 Ml , Ringer Acetate Infusion 500 Ml , Sodium Chloride 0.45% W / V Polypack 500 Ml , 27. Drugs For Urology , Finasteride Tablets Ip 5 Mg , Tamsulosin Hcl Tablets / Capsule 0.4 Mg , Flavoxate Tablets Ip / Bp 200 Mg ( Coated Tablet ) , Savelamer Carbonate Tablet 400 Mg ( Each Film Coated Tablet Contains Savelamer Carbonate 400 Mg ) , Sodium Bicarbonate Tablet Usp 1 Gm ( Each Film Coated Tablet Contains Sodium Bicarbonate Usp 1 Gm ) , Levamisol Hydrochloride Tablet Ip 50 Mg ( Each Uncoated Tablet Conatin Levamisol Hydrochloride Ip 50 Mg ) , Phenazopyridine Tablet 5 Mg , Dutasteride Tablet 0.5 Mg , Alkylizer Syrup 1.4 Gm / 5 Ml ( 100 Ml ) ( Disodium Hydrogen Citrate ) , 28. Antivertigo , Betahistine Tab Ip 8 Mg , Betahistine Tab Ip 16 Mg , Cinnarizine Tablets Ip 25 Mg , Cinnarizine Tablet Ip 75 Mg , 29. Vitamins And Minerals , Ascorbic Acid Tab Ip 500 Mg , Calcium Gluconate Inj Ip 10% ( Iv Use ) , Ferrous Sulphate With Folic Acid Tab Ip Each Film Coated Tab. Containing Dried Ferrous Sulphate Ip-Equiv 100 Mg Elemental Iron And Folic Acid Ip 0.5 Mg , Ferrous Sulphate With Folic Acid Tab ( Paediatric ) Ip Each Film Coated Tab. Containing Dried Ferrous Sulphate Ip-Eqivalent To 20Mg Elemental Iron And Folic Acid Ip-100 Mcg , Folic Acid Tab Ip 5 Mg , Multivitamin Drops Each Ml Contains Vit A 3000 Iu, Vit D3 300 Iu, Vit B1 1Mg, Riboflavine Phosphate Sodium 2Mg, D-Panthenol 2.5Mg, Niacinamide 10Mg, Pyridoxine Hcl 1Mg, Cyanocobalamin 1Mcg, Lysine Hcl 10Mg , Multivitamin Tablets Nfi Formula Sugar Coated Vit A 2500 Iu Vit B1-2Mg Vit-B6-0.5Mg Vit-C-50Mg Calcium Pantothenate-1Mg Vit-D3-200Iu Vit-B2-2 Mg Niacinamide-25Mg Folic Acid-0.2 Mg , Vitamin B Complex Inj Nfi , Vitamin B Complex Tablet Nfi ( Prophylactic ) B1 2Mg B2-2Mg B6- 0.5Mg Niacinamide 25Mg Calcium Pantothenate 1Mg ( With Appropriate Overages ) , Vitamin A Paediatric Oral Solution Ip ( Vitamin A Concentrate Oil Ip ) Each Ml Contains Vitamin A 100000 Iu , Calcium And Vitamin D3 Suspension ( Each 5 Ml Contains Calcium Carbonate Equivalent To Elemental Calcium 250 Mg, Vitamin D3 125 Iu ) , Iron And Folic Acid Suspension. Each 5Ml Contains Ferrous Fumerate Equivalent To Elemental Iron 100Mg, Folic Acid 500 Mcg , Zinc Sulphate Dispersible Tablets Ip Elemental Zinc 10 Mg , Iron Sucrose Injection Usp / Bp 20Mg / Ml ( For Iv Use ) Each Ml Contains Ferric Hydroxide In Complex With Sucrose Equiv. To Elemental Iron 20 Mg , Calcium With Vitamin D Tablets Usp / Calcium And Colecalciferol Tablets Bp / Calcium And Vitamin D3 Tablets Ip ( Elemental Calcium 500 Mg, Vitamin D3-250 Iu ) ( Non-Chewable ) , Cholecalciferol Granules 60, 000 Iu / Gm , Mecobalamin Inj 500 Mcg / Ml , Pyridoxine Tablet Ip 10 Mg , Pyridoxine Tablet Ip 40Mg , Thiamine Tablets Ip 100 Mg , Calcitriol Capsules Ip 0.25 Mcg , Methyl Cobalmine Tablet 500Mcg , Methyl Cobalmine Tablet 1500Mcg , Vitamin D3 Oral Solution 60000 Iu , Ferric Carboxymaltose Injection 50 Mg / Ml 10 Ml Size , Multi Vitamin Syrup , 30. Miscellaneous Drugs , Flunarizine Tab 5 Mg , Black Disinfectant Fluid ( Phenyl ) As Per Schedule O Grade Iii , Conc Haemodialysis Fluid B.P Acetate Concentrate 10 Litre Can , Peritonial Dialysis Solution Ip , Sodium Bicarbonate Inj Ip 7.5% W / V , Water For Inj Ip , Alendronate Sodium Tablets Usp / Bp 35 Mg , Mannitol With Glycerin Injection 10 O / O + 10 O / O W / V ( For Intravenous Infusion ) , Normal Human Intravenous Immunoglobulin 5G / 100Ml , Pregabalin Cap Ip 75 Mg , Surfactant For Intratrecheal Instillation ( Natural Bovine Lung Surfactant ) , Concentrated Solution For Hameodialysis Bp Sodium Hydrogen Carbonate Concentrate In 10 Litre Cans , Intravenous Fat Emulsion 20% W / V 250Ml , Pyridostigmine Tablet Usp 60 Mg ( Each Tablet Contains Pyridostigmine Usp 60 Mg ) , Caffeine Citrate Usp Injection 20Mg / Ml ( Equivalent To 10 Mg Caffeine Base / Ml ) 3Ml Size , Amino Acid 10% Injection 100Ml Size , Vitamin E Capsule 400 Mg , Inj Practant Alpha 80 Mg / Ml In Pack Of I05 Ml ( Detail In Rc ) , 31. Absorbable Sutures , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 3 / 8 Cir Rb Needle 40 Mm Length 76 Cm ) Size -1 / 0 , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 1 / 2 Cir Rb Needle 20 Mm Length 76 Cm ) Size -3 / 0 , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 1 / 2 Cir Rb Needle 30 Mm Length 76 Cm ) Size -2 / 0 , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 1 / 2 Cir Rb Needle 30 Mm Length 76 Cm ) Size -1 / 0 , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 1 / 2 Cir Rb Needle 40Mm Length 76 Cm ) Size -1 / 0 , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 3 / 8 Cir Rb Needle 30 Mm Length 76 Cm ) Size-2 / 0 , Absorbable Surgical Suture ( Sterile Catgut ) Bp / Usp Needled Suture Chromic ( 1 / 2 Cir Rb Needle 45 Mm Length 100 Cm ) Size-1 , Absorbable Surgical Suture ( Sterile Catgut ) , Needled Suture Chromic Size-3 / 0 ( 3 / 8 Cir Rcutting Needle 26Mm, Length 76 Cm ) , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size - 3 / 0 1 / 2Cir Rb Needle 20Mm Length 70 Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-2 / 0 1 / 2 Cir Rb Needle 30Mm Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) 1 / 2 Cir Rb Needle Size-1 / 0 30Mm Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size 1 1 / 2 Cir Tapercut Needle ( Heavy ) 40Mm Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-1 1 / 2 Cir Rb Needle40mm Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-3 / 0 ( 1 / 2 Cir Conventional 25Mm Length 90 Cm ) Undyed , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-4 / 0 ( 1 / 2 Cir Rb Needle 20Mm Length 70 Cm ) , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-2 / 0 1 / 2 Cir Rb Needle 40Mm L 90Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-1 / 0 ( 1 / 2 Cir Rb Needle 40Mm Length 90 Cm ) , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size 3 / 0 3 / 8 Circle Cutting Needle 22Mm Length 45 Cm , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled ( Braided ) Coated Polyglactin / Polyglycolic Acid / Poly ( Glycolide-Co-L-Lactide ) Size-4 / 0 3 / 8 Circle Cutting 16Mm Needle, Suture Length 70Cm , Chromic Catgut Suture ( 3 / 8 Cir Rcutting Needle 16 Mm, Suture Length 76 Cm ) Size 5 / 0 , Chromic Catgut Suture ( 3 / 8 Cir Cutting Needle 8 Mm, Suture Length 35 Cm ) Size 6 / 0 , Chromic Catgut Suture ( 3 / 8 Cir R Cutting Needle 19 Mm Needle, Suture Length 76 Cm ) Size 4 / 0 , 32. Non Absorbable Surgical Suture Sterilised Surgical Needled Suture , Non Absorbable Surgical Suture, Sterilised Needled Black Braided Silk Size 3 / 0 ( 1 / 2 Cir Rb Needle 20Mm, Length 76 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Black Braided Silk Size 3 / 0 ( 3 / 8Cir Reverse Cutting Needle 26Mm, Length 76 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Black Braided Silk Size 2 / 0 ( 3 / 8Cir Reverse Cutting Needle 45Mm, Length 76 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 8 / 0 ( 3 / 8 Cir Micropoint Round Body , 6Mm Length 38 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 3 / 0 ( 3 / 8 Conventional Cutting Needle 16Mm Length 70 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 4 / 0 ( 3 / 8 Conventional Cutting Needle 19Mm Length 60 Cm. ) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 5 / 0 ( 3 / 8 Cir Slim Blade Cutting Needle 15Mm Length 70 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 2 / 0 ( 3 / 8 Cir R Cutting Needle 45Mm Length 70 Cm. ) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 1 / 0 ( 3 / 8 Cir R Cutting Needle 45Mm Length 70 Cm. ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5 / 0 ( 1 / 2 Cir Rb 13 Mm Needle, Length 75Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 6 / 0 ( 3 / 8Cir Rb Taper Point Double Needle 9.3Mmlength 60 Cm ) / ( 3 / 8Cir Rb 16 Mm Needle, Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 7 / 0 ( 3 / 8Cir Rb Double 8Mm Needle, Length 60 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5 / 0 ( 3 / 8Cir Rb 16 Mm Needle, Length 70 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1 / 0 ( 1 / 2 Cir Rb Needle 30Mm Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1 ( 1 / 2 Cir Rb Heavy Needle 45Mm Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5 / 0 ( 1 / 2 Cir Rb Double Needle 17Mm Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 4 / 0 ( 1 / 2 Cir Tapercut Double Needle 17Mm Length 70 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3 / 0 ( 1 / 2 Cir Rb Needle 25Mm, Length 90 Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 2 / 0 ( 1 / 2 Cir Rb Needle 30Mm, Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3 / 0 ( 1 / 2 Cir Tapercut Needle 17Mm Length 75 Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 2 / 0 ( 1 / 2 Cir Tapercut Needle, 25 Mm Length 90 Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 6 / 0 ( 3 / 8 Cir Conventional Cutting Pc-3Needle 15Mm Length 60Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 6 / 0 ( 3 / 8 Cir Rb 13Mm Needle, Length 90 Cm Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 4 / 0 ( 1 / 2 Cir Rb Needle 16 Mm Length 70 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3 / 0 ( 3 / 8 Cir Cutting Needle 25Mm Length 45 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1 ( 1 / 2 Cir Rb Heavy 40Mm, Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1 ( 1 / 2 Cir Reverse Cutting, 45 Mm Needle Length 100 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 8 / 0 ( 3 / 8 Cir Rb , 8Mm Double Needle, Suture Length Of 70Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 4 / 0 ( 1 / 2 Circle Tapercut 13Mm Double Needle 70Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5 / 0 ( 1 / 2 Circle Cc 13Mm Needle, Suture Length Of 70Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 2 / 0 ( 1 / 2 Circle Tapercut Needle 17Mm Suture Length Of 90Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3 / 0 ( 1 / 2 Cir Rb Needle 25Mm, Suture Length Of 75Cm ) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Polybutylate / Silicon Coated Polyster Braided Green / Blue Size 4 / 0 ( 1 / 2 Cir Tapercut , 17 Mm Double Needle, Length 75 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Polybutylate / Silicon Coated Polyster Braided White Size 2 / 0 ( 1 / 2 Cir Tapercut , 17 Mm Double Needle, Length 90 Cm ) , Non Absorbable Surgical Suture, Sterilised Needled Polybutylate / Silicon Coated Polyster Braided Green / Blue Size 2 / 0 ( 1 / 2 Cir Tapercut , 17 Mm Double Needle, Length 90 Cm ) , Non Absorbable Surgical Suture Sterilized Needled Polybutylate / Silicon Coated With Polyster Braided ( Green / Blue ) Size 2 / 0 1 / 2 Circle Taper Cut, 17Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X 1.5Mm , Non Absorbable Surgical Suture Sterilized Needled Polybutylate / Silicon Coated With Polyster Braided ( Green / Blue ) Size 2-0 1 / 2 Circle Taper Cut, 25Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X 1.5Mm , Non Absorbable Surgical Suture, Sterilised Needled Coated Polyster Braided, Green / White Or Blue / White Coated Polyster Braided ( Green / Blue ) With Size 3 / 0 1 / 2 Circle Tapercut Double Needle 25Mm, Suture Length 90 Cm , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black ( Nylon ) Size 10 / 0 ( 3 / 8 Cutting Spatulated Edge Needle, Double Arm Needle 6 Mm, Suture Length 30-42 Cm , B.B Silk Suture ( 3 / 8 Cir Rb Needle 20Mm, Length 76 Cm Size 4 / 0 , B.B Silk Suture ( 3 / 8 Cir Rb Needle 16Mm, Length 76 Cm Size 5 / 0 , 34. Polyglecraprone 25 Monofilament Sutures , Absorbable Surgical Sutures, Sterilised Needled Polyglecaprone / Polyglyconate, Monofilament Sutures Size 2 / 0 ( 1 / 2 Circle Oval Rb Needle 26Mm Needle, Suture Length Of 70Cm ) , Absorbable Surgical Sutures Sterilised Needled Monofilament Polyglecaprone / Polyglyconate, Size 3 / 0 ( 1 / 2 Circle Ovalrb Contrast Needle 26Mm, Suture Length 70Cm ) , Absorbable Surgical Sutures Sterilised Needled Monofilamentpolyglecaprone / Polyglyconate Size 4 / 0 ( 1 / 2 Circle Cutting 16Mm Needle, Suture Length 70Cm ) , Absorbable Surgical Sutures Sterilised Needled Monofilamentpolyglecaprone / Polyglyconate Size 3 / 0 ( 3 / 8 Circle Cutting 25Mm Needle, Suture Length Of 70Cm ) , 35. Monofilament Polydioxanone Suture , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled Suture Monofilament Polydioxanone Violet Size 1 ( 1 / 2 Circle Reverse Cutting 50 Mm Length 90Cm ) , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled Suture Monofilament Polydioxanone Violet Size 2 / 0 ( 1 / 2 Circle Rb 31Mm Needle, Length 70Cm ) , Absorbable Surgical Suture ( Synthetic ) Sterilised Needled Suture Monofilament Polydioxanone Violet Size 1 / 0 ( 1 / 2 Circle Rb 30Mm Needle, Length 70Cm ) , 36. Antibacterial Coated Suture , Absorbable Surgical Suture ( Synthetic ) Antibacterial Coated Sterilised Needled ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 1 1 / 2 Circle Ct Round Bodied 40Mm, Gs Needle, Suture Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Antibacterial With Sterilised Needled ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 1 / 0 1 / 2 Circle Ct Round Bodied 40Mm, Gs Needle, Suture Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Antibacterial With Sterilised Needled Suture ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 2 / 0 1 / 2 Circle Round Bodied 30Mm, Suture Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Antibacterial With Sterilised Needled Suture ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 1 1 / 2 Circle Reverse Cutting, Os 40Mm, Suture Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Antibacterial With Sterilised Needled Suture ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 1 / 0 1 / 2 Circle Reverse Cutting 36Mm, Os Needle, Suture Length 90 Cm , Absorbable Surgical Suture ( Synthetic ) Antibacterial With Sterilised Needled Suture ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 3 / 0 1 / 2 Circle Round Bodied 20Mm, Suture Length 70 Cm , Absorbable Surgical Suture ( Synthetic ) Antibacterial With Sterilised Needled Suture ( Braided Coated Polyglactin / Polyglycolic Acid Violet ) Size 3 / 0 3 / 8 Circle R Cutting, Ps-1, 24Mm, Suture Length 70 Cm , 37. Surgicals , Absorbable Gelatin Sponge 80 X 50X 10Mm , Absorbent Cotton Wool Ip 500 Gm ( Net Weight ) , Ortho Cotton Roll 5 Inch200 Gmortho C ( Net Weight ) , Ortho Cotton Roll 10 Inch500 Gmortho C ( Net Weight ) , Asepto Syringe With Transparent Bulb Sterile, 60 Ml , Blood Administration Set Blood Transfusion Set , Gloves Size 6.5 Inches, Powdered ( Disposable Sterile Surgical Rubber Gloves ) , Gloves Size 6.5 Inches, Powder Free ( Disposable Sterile Surgical Rubber Gloves ) , Gloves Size 7 Inches, Powdered ( Disposable Sterile Surgical Rubber Gloves ) , Gloves Size 7 Inches, Powder Free ( Disposable Sterile Surgical Rubber Gloves ) , Gloves Size 7.5 Inches, Powdered ( Disposable Sterile Surgical Rubber Gloves ) , Gloves Size 7 .5Inches, Powder Free ( Disposablesterile Surgical Rubber Gloves ) , Suction Catheter, Sterile.Size: Fg 5 , Suction Catheter, Sterile. Size: F G-6 , Suction Catheter, Sterile. Size: F G-8 , Suction Catheter, Sterile. Size: F G-10 , Suction Catheter, Sterile. Size: F G-12 , Suction Catheter, Sterile. Size: F G-14 , Suction Catheter, Sterile. Size: F G-16 , Suction Catheter, Sterile. Size: F G-18 , Suction Catheter, Sterile. Size: F G-20 , Suction Catheter, Sterile. Size: F G-22 , Catheter, Size 8 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Catheter, Size 10 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Catheter, Size 16 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Catheter, Size 18 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Catheter, Size 20 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Catheter, Size 22 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Catheter, Size 24 ( Foleys Ballon Catheter Sterile, 2 Way For Urinary Drainage, Single Use, ) Silicon Coated Natural Latex Material , Infant Feeding Tube Size 10Fg , Infant Feeding Tube Size 8Fg , Infant Feeding Tube Size 5Fg , Perfusion Set With Airway And Needle, ( Adult Use ) Sterile Disposable , Perfusion Set ( Infusion Set ) With Airway And Needle ( Paediatric Use ) Sterile Disposable , Infusion Set With Microdrip, ( I.V. ) Sterile Disposable , Insulin Syringe ( 40 Units ) With ( Fixed ) 30 G Needle Shall Conforn To Is 12227 , Sterile Disposable ( Single Use ) Teflon / Ptfe I.V Cannula With Integrated 3 Way Stop Cock Size 16G , Sterile Disposable ( Single Useteflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. ) Size 18G , Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock.Size 20 G , Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock.Size 22G , Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula Without Port Size 24G , Mucus Extractor Sterile , Nasal Oxygen Set, Twin Bore All Sizes Adult , Nasal Oxygen Set, Twin Bore All Sizes Paediatrics , Paper Adhesive Plaster 1 Inch X 9.0 Mts ( With Cutter ) Non Woven Adhesive Tape , Paper Adhesive Plaster 2 Inch X 9.0 Mts ( With Cutter ) Non Woven Adhesive Tape , Paper Adhesive Plaster 3 Inch X 9.0 Mts ( With Cutter ) Non Woven Adhesive Tape , Plaster Of Paris Bandage 15Cm X 2.7 Mts / Roll , Plaster Of Paris Bandage 10Cm X 2.7Mts , Ryles Tube / Nasogastric Tube Size: 10 , Ryles Tube / Nasogastric Tube Size: 12 , Ryles Tube / Nasogastric Tube Size:14 , Ryles Tube / Nasogastric Tube Size: 16 , Ryles Tube / Nasogastric Tube Size: 18 , Scalp Vein Set ( Disposable ) Size 18G , Scalp Vein Set ( Disposable ) Size 20G , Scalp Vein Set ( Disposable ) Size 22G , Scalp Vein Set ( Disposable ) Size 24 G , Syringe 2 Ml Hypodermic With Needle Attached 24G, Sterile, Single Use Disposable , Syringe 5 Ml Hypodermic With Needle Attached 24G, Sterile, Single Use Disposable , Syringe 10 Ml Hypodermic With Needle Attached 22G, Sterile, Single Use Disposable , Syringe 20 Ml Hypodermic With Needle Attached 22G, Sterile, Single Use Disposable , Surgical Blade Sterile, Size 11 , Surgical Blade Sterile, Size 15 , Surgical Blade Sterile, Size 22 , Suture Needles Curved 1 / 2 Circle Round Body Assorted Size 11-15 , Suture Needles Curved 1 / 2 Circle Round Body Assorted Size 1-5 , Suture Needles Curved 1 / 2 Circle Round Body Assorted Size 16-20 , Suture Needles Curved 1 / 2 Circle Round Body Assorted Size 6-10 , Suture Needles Curved And Cutting 1 / 2 Circle Cutting Size 6-10 , Suture Needles Curved And Cutting 1 / 2 Circle Size 11-15 , Suture Needles Curved And Cutting 1 / 2 Circle Size 16-20 , Suture Needles Curved And Cutting Size 1-5 , Sterile Disposable Spinal Needle For Single Use. 22G X 3 1 / 2 Inch , Sterile Disposable Spinal Needle For Single Use. 25G X 3 1 / 2 Inch , Urine Collecting Bag, Disposable 2000 Ml , Double J Stent, Sterile, Both Ends Open - Size 4F, Length 16 Cm , Double J Stent, Sterile, Both Ends Open, Size 5F, Length 20 Cm , Double J Stent, Sterile, One End Closed - Size 4F, Length 16 Cm , Double J Stent, Sterile, One End Closed, Size 5F, Length 20 Cm , Endotracheal Tube, Plain - Size 2.5 , Endotracheal Tube, Plain - Size 3 , Endotracheal Tube, Plain - Size 3.5 , Endotracheal Tube, Plain - Size 4 , Endotracheal Tube, Plain - Size 4.5 , Endotracheal Tube, Plain - Size 5 , Endotracheal Tube, Plain - Size 5.5 , Endotracheal Tube, Plain - Size 6 , Endotracheal Tube, Plain -Size 6.5 , Endotracheal Tube, Plain - Size 7 , Endotracheal Tube, Plain - Size 7.5 , Endotracheal Tube, Plain - Size 8 , Endotracheal Tube, Plain - Size 8.5 , Endotracheal Tube, Cuffed - Size 4 , Endotracheal Tube, Cuff - Size 4.5 , Endotracheal Tube, Cuff - Size 5 , Endotracheal Tube, Cuff - Size 6 , Endotracheal Tube, Cuff- Size 6.5 , Endotracheal Tube, Cuff - Size 7 , Endotracheal Tube, Cuff - Size 7.5 , Endotracheal Tube, Cuff - Size 8 , Endotracheal Tube, Cuff - Size 8.5 , Endotracheal Tube, Cuff - Size 9 , Tracheostomy Tube, Plain - All Sizes , Tracheostomy Tube ( Pvc ) , Cuffed - All Sizes , Abdominal Drain Kit ( With Collection Bag 2000 Ml Size 24 , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag ( 2000 Ml ) Size 28 , Abdominal Drain Kit, Sterile, Having Drainage Cather And Collection Bag ( 2000 ) Ml Size 32 , Corrugated Drainage Sheet - All Sizes , Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.6Cm X 15Cm Or 7.5Cm X 15Cm , Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 Cm X 15 Cm , Sterilized Umbilical Cotton Tape Width 3 Mm, Length 75 Cm , Bone Wax Sterilised , Temporary Cardiac Pacing Wire ( Electrode ) Sterile ½ Cir, Tapercut, 26 Mm; Reverse Cutting 60 Mm , Skin Graft Knife Blade ( Sterile ) & Handle , K Wire, Length 375 Mm; 1Mm , K Wire, Length 375 Mm; 1.6Mm , K Wire, Length 375 Mm; 1.8Mm , Face Mask, Disposable , Surgical Cap Disposable ( For Surgeons ) , Surgical Cap, Disposable ( For Nurses ) , Foldable Intra Ocular Lense With Injector 11 To 17.5 , Foldable Intra Ocular Lense With Injector18 To 24 , Foldable Intra Ocular Lense With Injector 24.5 To 28.5 , Standard Pama Intra Ocular Lenses 11 To 17.5 ( Pc-Iol ) , Standard Pama Intra Ocular Lenses ) 18 To 24 ( Pc-Iol ) , Standard Pama Intra Ocular Lenses24.5 To 28.5 ( Pc-Iol ) , Disposable Sterile Surgical Rubber Gloves Size 8 Inches, Powdered , Disposable Sterile Surgical Rubber Gloves Size 8 Inches, Powder Free , Rubber Examination Gloves, Non-Sterile, Extra Small , Rubber Examination Gloves, Size Small , Rubber Examination Gloves, Size Medium , Rubber Examination Gloves Made Of Natural Rubber Latex, Non-Sterile, Size Large , Pressure Monitoring Line / High Pressure Extension Line , Urine Collecting Bag For New Born / Paediatric Urine Collection Bag, Capacity 100Ml , Umbilical Catheter For New Born, All Sizes - , Umbilical Cord Clamp , Absorbable Oxidized Regenerated Cellulose Netsize 2 X 3 Topical Absorbable Haemostatic Bactericidal Property , Close Wound Drainage Device Under Negative Pressure ( Closed Wound Suction Unit ) Size Of Bellow 800 Ml, Catheter Size 16 , Close Wound Drainage Device Under Negative Pressure ( Closed Wound Suction Unit ) Size Of Bellow 800 Ml, Catheter Size 18 , T-Tube For Common Bile Duct Drainage, Length 20X60 Cm, Size- , Bone Cement , Sanitary Napkin Beltless , Sanitary Pads Belt Type , Sanitary Napkin Beltless With Wings , Oxygen Mask ( Adult ) , Oxygen Mask ( Pediatric ) , Foleys Catheter No. 14 , Nelaton Catheter Size 14 Fg , Ecg Electorde ( Details In Rc ) , Surgical Blade Sterile, Size 23 Single Peel Package In Metal Foil As Per Is3319 ( Details In Rc ) , Sterile Hyoidemic Syringe With Needle Attached 22 G Single Use 50 Ml ( Details In Rc ) , Urethralcatheter 90 ( Fg-14 ) Made Of Medical Grade Pvc ( Details In Rc ) , Urethralcatheter 91 ( Fg-10 ) Made Of Medical Grade Pvc ( Details In Rc ) , Vaccum Suction Set, 2.5Meter Length ( Details In Rc ) , Epidural Minipack 18G, 80Mm-90Mm, Metal Stylet For Single Use Only, Sterile ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 16, Double Lumen Size 30 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 18 Double Lumen Size 30 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 20 Double Lumen Size 30 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 22 Double Lumen Size 30 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 16 Double Lumen Size 45 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 18 Double Lumen Size 45 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 20 Double Lumen Size 45 Cm ( Longline Iv ) ( Detail In Rc ) , Vascular Catheter With Metal Guide No. 22 Double Lumen Size 45 Cm ( Longline Iv ) ( Detail In Rc ) , 3 Way Stop Cock , Non Pyrogenic And Single Use, Should Be Leak Proof, With Smooth Movements ( Detail In Rc ) , 3 Way Stop Cock With Extension Tube ( Vein-O Extension Line ) Size 10Cm ( Non Pyrogenic & Single Use ) ( Detail In Rc ) , 3 Way Stop Cock With Extension Tube ( Vein-O Extension Line ) Size 50Cm ( Non Pyrogenic & Single Use ) ( Detail In Rc ) , 3 Way Stop Cock With Extension Tube ( Vein-O Extension Line ) Size 100Cm ( Non Pyrogenic & Single Use ) ( Detail In Rc ) , 3 Way Stop Cock With Extension Tube ( Vein-O Extension Line ) Size 150Cm ( Non Pyrogenic & Single Use ) ( Detail In Rc ) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag ( 2000 Ml ) ( Size 16 ) ( Detail In Rc ) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag ( 2000 Ml ) ( Size 20 ) ( Detail In Rc ) , Nasal Pronge Neonatal ( Flexible Medical Grade, 2 Meter Long, Multichannel Kink Resistance Tube ( Detail In Rc ) , Elastic Adhesive Bandage Bp 10Cm X 1Mtr Stretched Length Adhesive Material Should Have Good Quality Sticking Property ( Detail In Rc ) , Sterile Disposable ( Single Use Teflon / Ptfe I.V Cannula With Integrated 3 Way Stop Cock Size 26G ( Detail In Rc ) , Niv Mask ( Noninvasive Ventilation Mask ) Oro Nasal Covering ( Nose & Mouth ) Mask Adult Large Size For Ventilator Without Vent ( Detail In Rc ) , Niv Mask ( Noninvasive Ventilation Mask ) Oro Nasal Covering ( Nose & Mouth ) Mask Adult Medium Size For Ventilator Without Vent ( Detail In Rc ) , Niv Mask ( Noninvasive Ventilation Mask ) Oro Nasal Covering ( Nose & Mouth ) Mask Adult Large Size For Bipap With Vent ( Detail In Rc ) , Niv Mask ( Noninvasive Ventilation Mask ) Oro Nasal Covering ( Nose & Mouth ) Mask Adult Medium Size For Bipap With Vent ( Detail In Rc ) , Niv Mask ( Noninvasive Ventilation Mask ) Oro Nasal Mask Paediatric With Bronchoscopy And Co2 And O2 Port With Chin Support ( Detail In Rc ) , Nebulization Mask Adult ( Detail In Rc ) , Nebulization Mask Paediatric ( Detail In Rc ) , Chemotherapy Port And Non-Coring Needles ( Adult ) ( Detail In Rc ) , Chemotherapy Port & Non-Coring Needles ( Pediatric ) ( Detail In Rc ) , 38. Swine Flu Drugs , Oseltamivir Capsule Ip 75 Mg Capsule ( Each Capsule Contains Oseltamivir Phosphate Equivalent To Oseltamivir 75 Mg ) , Oseltamivir Capsule Ip 45 Mg Capsule ( Each Capsule Contains Oseltamivir Phosphate Equivalent To Oseltamivir 45 Mg ) , Oseltamivir Capsule Ip 30 Mg ( Each Capsule Contains Oseltamivir Phosphate Equivalent To Oseltamivir 30 Mg ) , Oseltamivir Phosphate For Oral Suspension Ip 12 Mg / Ml ( Each Ml Contains 12 Mg Oseltamivir Base After Reconstitution ) , Oseltamivir Phosphate For Oral Suspension Ip 12 Mg / Ml ( Each Ml Contains 12 Mg Oseltamivir Base After Reconstitution ) , 40 Anti-Malerial Drugs , Act Kit Containing 3 Tablets Of Artesunate ( 25Mg Each ) And 1 Tablet Of Sulphadoxine And Pyrimethamine ( 250Mg+12.5Mg ) , Act Kit Containing 3 Tablets Of Artesunate ( 50 Mg Each ) And 1 Tablet Of Sulphadoxine And Pyrimethamine ( 500Mg+25Mg ) , Act Kit Containing 3 Tablets Of Artesunate ( 100 Mg Each ) And 1 Tablet Of Sulphadoxine And Pyrimethamine ( 750Mg+37.5Mg ) , Act Kit Containing 3 Tablets Of Artesunate ( 150 Mg Each ) And 2 Tablet Of Sulphadoxine And Pyrimethamine ( 500Mg+25Mg ) , Each Combi Bliste Pack: Containing 3 Tablets Of Artesunate ( 200 Mg Each ) And 2 Tablet Of Sulphadoxine Pyrimethamine ( 750Mg+37.5Mg ) Each Or 3 Tablets Of Sulphadoxine Pyrimethamine ( 500+25 ) Mg , Group Name ( 1 ) :: 42 Covid19 , Liposomol Amphotericine Injection B 50Mg , Group Name ( 2 ) :: Eye , Creseent 2.5Mm , Lens Tip 15 Dgree Angal , Kerotone 2.8Mm , Needle No.26 , Needle No.24 , Pilo Carpine Nittrate 0.5% Injection , Drop Proparacaine Hcl Opthalmic Solution 0.5% , Droptropicamide With Phenylephrine Opthalmic 5 Ml Solution , In R, L. 500Ml Glass Bottle ( Compund Sodium Lactate Injection 500Ml ) , Korsolex Rapid 500Ml ( Glutaraldehyde 15 Gm 1.6 Dihydroxy 2.5 Dioxahexane 19.7 Gm Rust Inhibitions ) , Trypen Blue Dye 2Ml , Gauzethan Unmedicated ( 120Cmx9mtr ) Weight 325 Grm , Ordinary Bandage ( 15Cmx4mtr ) Weight 412 Grm , Ordinary Bandage ( 10Cmx4mtr ) Weight 275 Grm , Amphoter Jcin B Ip Gel 1, 0 Mg Each Gnp Contain Amphoteticinb L0mg Gel , Crotaniiton 10% * Hvdrocortjsone 0.25% Cream , Methottexate Gel 1% , Eflomithine Hydrochlori De Eteam 139 Rug, Each Gm Contain Eflomithine Hydrochloride139 Rna , Beclomethasone Dipropionat°0.064%+ Salycylic Acid 3% Lotion , Metlioxsalcn1% Lotion. Each Ml Contain Metfioxsaten1% , Deca Peptide 6 Mg Lotion. Each Nil Contain Dcca Peptide 6 Mg , Minocycline .5Omg , Trioxsalen 5Mg Tabeech Film Coded Tablei Contain Trioxsaleu5mg , Trioxsalen 25Mg Tab. Each Film Coated T8blet Contain Trioxsalen 25Mg , Trichlotoacctic Acitl ( Tca ) 50% W / V Lction , Jnj.Hvian G F 20 , Hepflto Protective Tablet Each Film Coated Tablet To Contain.Matadoxine 500Mg, Silyaarin L40mg, L-Ornithine L-Aspertatc 15Oing, P Yridoxiue H Ydrochloride 3Mg, Rolle Acid 1.5Mg , Spores Of Polyantib Iotic-Resistant Bsci Plus Clausii-2Billion Capsules , Iron As Ferric 8Acchaiate Rind Phospholipidclewable Tablets- ( In Micro Encapsulatedtorn ) 75 Nag Crt. To Elementaliron30 Mg Phospholipid167 Mg Uq. To Phosphatidylserine 100 Mg , Cojugated Cstrogen 0.3 Na G Ta6.Each Tablet Contain 0.3 Mg Co Jugated Cstrogen , Telinisarien40mg *Hydroclorothiazirlcl 2.5 Nag J.P.Eachiab1et Contain Felniisartan40nlg *Hydroclor Ithiazide 12. 5 My , 1 Elmisartan80mg *Idydroclorothiazide25 Nag, L.P.Each Tablet Contain 4Cin1isartau80mg *Hydroclorithiazide 25 Mg, , Mefenunic Acid *5Omg* Dicyclomine Hytlrochlotidel0mg Each ’1Nb1et Contain Mefcn+Imie Acid 25 Omg* Dicyelominthyarochloride 1Omg , Conibik It Oi ( Lab Fjueonazole 15 F ) Ing *Azithromyci0lgm A Secnidazcl E I Gm ) Fach Kit Containltab Tñuconazolel S0mg *1 Tab Azjthromycin1 Gn & 2 Tab.Secnidazcle Lgm , Dolutegravir 50, Each Film En &-Tablet Contain Doltltegrevir Sodium 50 , Tcnofovtr 300J-La Nivudinc300.Fach Film Coated Tabtet Contain Teno Fovir Di.Soproxiltiimerete30 Oing& Lamivudine300mg , Fitavirenz 600 Each Film Coated Tablet Contsin Efavircnz 6 ( ) 0 Mg , Nwirapine 200 Each Tebltt Containnevirnpine 200Mg , Atazanavit3 00*Ritonflvir 100, Eachtablet Contain Atazanavir Sulphate 30Ftnag*Ritonavir Ip100mg , Tenofovir Alafinamide25*F Mtrieitsbine20o+ Doultegravir5 0 Each Tablei Contain Âeno Tovifat Atinamide25mg *Lmtncitabine200nagsdoultegmvi 50Mg , Abacavii300 Eachtablet C‹›Ntain Abacavir 300Me Tp , Eainivudinet00 Lach Tablet Contain 1.Amivudine 100 Mg , Raltegravir 400F.Ach Film Coated Tablet Contain Ltaltcgravir 400 Mg , Zidmvudine 6Fh- Semi Udinc 30 , Ultrasoundcontrast Acent ( Sulphur Hexafluoride ) Sonovue , Contrast For Ct Scan / Ivp / Special Investigations , Iopamidolctcontrast Solution For In Jectiuon , Iopamidol Ct Contrast Solution For Injectiuon , Contrast For Special Investigations ( Barium Sulphate Powder ) , Contrast For Special Investigations ( Barium Sulphate Pow Dcr ) , Contrast For Specialinvestigations ( Barium Sulphate Suspension ) High Density Low Viscosity , Contrast For Special Investigations ( Barium Sulphide Suspension ) High Density Low Viscosity , Contrast Forspecial Investigations ( Barium Sulphate Paste ) , Oral Contrast For Mri ( Ferric Ammonium Citrat / Mineral Oil / Corn Oil , Oral Contract Forct { Diatnzoate Sodium & Diatrozoatemeglumine ) , Lopromidc Ct Contrast Usfda / Ceapproved , 1Oproinidc Ct Contrast Usfda / Ceapproved , Lodixanol Ct Contrast 320 Rugi / 100R1 In Polypropylenebottle Usfda Approved , Lodixanolm Content 320 Rugi / L00mlin Polypropylenebottle Us Fda , Lolrolonct Contrastusfd.Nice Approved , Lotrolon Ct Contrastusfda / Ceapproved , Venlafaxime Teb. , Olanzapinein J. , Flupcntixolini. , Memantine Tab , Glycopyrrolate Tab. , Pramipexole Tab. , Pramipexole Tab. , Pramipexole Tab. , Injpropofol Mct / Lct With Oleic Acid Inj.Iv , Inj.Paracetamol Infusion 1000 Mg In Double Sterilisedclosed System L00% Biodegradable Eco Friendly Polyolefin100 Ml Bag , Nalbuphine Inj . , Chlorprocaine Inj. , Desflurane 100M1 , Geloufusion Infusion , Albumin5% Infusion , Inj.0.9% Norlral Saline500 Ml In 100% Hiodegradeble Non Delip Double Stmilizcdpoll Oletiii Closedsvstcm Bag , Inj0.9% Normal Seline 1000 Nil In L 00% Biodcgradable Non Dehp Double Sterilixzdtxilyolefin Closed System Bae , Inj. Ringers Lactate 500 Ml In 100% Bioflegra6able N On Dehp Double Sterilised Pojyolefin Closed Svstenabag , Inj. Fingers Lactatc1000 Ml Ini 00•Z» Biodegradablenondc -Ip Doc Ble Steril Ixcd Polvolefin Closed System Bag , Inj5% Dextrose 500 Ml In 10 0% Biodegradablenon Dfhp Double Sterilizcdpolvole Tin Closed Systembag , Inj. 5% Dns S00 Rrtl In 100% Bi Odcgrad Able Non Dehp Double Sterilised Polvole Fin Closed System Bag , Lnj. 0.9% N Ormaj Saline 10 0 Nil In 100% L›Iodegradable Non Dell P Dou Bie Sterilised Polyolefin Closed Systembag , Balance Salt Smutton With Ph. Of 7.2 To 7.4 Osmolarity 292 To 294 In 100% Biodegradable Double Sterilised Cl Ose0 Systemqulyotcfin 500 Ml Bag , Litj. Balance Hydroxy Ethyl 6% Tetra Starch 130 / 0. 4 In Plasma Adapted Solution500 Ml 100* Biodegradable Dag With Polyoletin , Lnj Hydroxy Ethyl 6% Tetrastarch130 / 0.4In Nacl500 Ml 100% Biodegradable Bag , Nifedipine Sublingual , Nifedipine Sublingual , Papaverine Inj. , Nicerdipinetab. , Topical Heparin Solution1000lu / Ml , Anti -Gasgangrene Scre 25000 I U / I Oinl Each Vial Contains- Closttidium Perferingcns Anti-Toxin 10000 Iu + Clostridiiim Ocderuetiens Antitoxin10000 1U *Clostridiuni Septicum Anti Toxin S000 Lu ) , Basiliximab 20 Mg Inj , Betamethisone And Neomvciacream 10.10%+0 5% ) , Solution Silver Nitrate 2% , Solution Silver Nitrate 5% , Solution Silver Nitrate 10% , Alkeline Nasal Douches ( Sodiumbicnrbonat + Sodium Biborate+ Sodium Chloride ) , Eer Drops Hydrocortisone 1%W / V A Cctic Aci 2%W / V , Ear Drops Each Ml Contain Cfiloramphenicol 4Mg + Dexamethasone1 Mg *Polymvxin B I 50001U ) , Nasal Drops Haeincosgulase Topical Solutioneach Nil Contain Aqueous Solution Othaemocoagluese 0.2 Cu , Triemcinolone Oroniucosal Paste B P 0. 1 % W / W , Ethiodizcd Oil ( Lipiodol ) Inj. , Htk Solution 1 Lit ( Hisiiiline - Tryptophan-Ketogluiarate Solutions ) , Glvcopeeyleted Extendedhalf Life Nonacoz Beta Pegol F Ix , Glycopegylated Extendedhalflifenonacoz Beta Pegol F Ix , Glvcopegylated Exten‹Ledhalflife Factor Viii , Glycopegylated Extended Half Life Factor Viii , Teuotovir Alafenamidefumerate ( Taf ) 25 Mgtab / Cap , Entccaviri Mg Tab Leap Film Coated , Dacalatasvir 30 Mgtab. / Cap , Decalatesvir 60 Nigtab.Leap , Sofosbuvir 400Mg Tab / Cap , Ribavitiij200 Me Tab. / Capfilm Coated , Nonabsorbablepolypropylene Light Weight Macroporous Mesh 30*30 Cm , Three Dimensional Monofilament Polyester Composite Mesh With Collagenwath Glycerolanti Adhesivebarrier Visceral Side And Stay Suture In Parietal Side Aiong With Medial Medial Marking Size 15 Cm Circular , Three Dimensional Monofilament Polyester Composite Mesh With Collagenwath Glycerolanti Adhesivebarrier Visceral Side And Stay Suture In Parietal Side Aiong With Medial Medial Marking Size 12 Cm Circular , Three Dimensional Monofilament Polyester Composite Mesh With With Collagen With Glycerol Antiadhesive Barrier Visceral Side And Stay Suture In Parietal Side Along Vith Medial Medtal Marking Size 20*15 Cm , Absorbable 5 Mm Herrua Mesh Fixate On Device 30 Screw Shaped With Proximal Wines Of Pgla Tacks Of .4.1 Mm Length Along With Flexible Shall Tip To 3 Cm , Absorbable 5 Mm Herrua Mesh Fixate On Device 15 Screwshaped With Proximal Wines Of Pgla Tacks Of .4.1 Mm Length Along With Flexible Shall Tip To 3 Cm , Non Absorbable 5Mmhernia Mesh Fixation Deviee With 30 Helical Shaped Titanauin Tacks 3.96 Mm Width And 0.61 Mm , 5Mm Nonabsorbable Helicalfastener Made Up Of Medical Grade Stainless Steel Covered With Atraumat Ie Polymer ( Peek ) Cap To Avoid Metal Exposure With 15 Fasteners , 5Mm Norabsorhablehelical Listener Made Up Of Medical %Ade Stainless Steel Covered With Atraumatc Polymer ( Peek ) Cap To Avoid Metâl Exposure With 30 Fasteners , Light Weight Rnorofilamentpolypropyl E Ae Meshdesign To Confirm Inguinal Anatomy, 3D Shape Size Large Left 10.8*16Cm / 15*10Cm , Light Weight Monofilamentpo1yropyienemesh, Designto Confirminguinalanatomy, 3D Shape Size Large Righ 10.8*16Cm / 15*10 Cm , Light Weight Monofilamentpolypropylenemesh Design To Confnr Inguinalara*Omy3d Shape Size Extra Large Left 12.4Cm*17.3 / 16*12Cm , Li%T Weghi Jnonofilarnent Polypropylene Mesh, Design To Contirr Inyiilal Anatomy, 3D Shape Size Extra Large Right 12.4Cm*17.3 / 16*12Cm , Battery Operated 60Mm Articulatmgendo Cutter With A Disposable Battery Pack, For Enhancecl Di Stat U } A Stability Wdile Firing, Hay Rgclosed Channel In The Eartrdige Jaw For Better Stabil Qty During Firing, 360 Degree Rotation Shaft And One Handed Natural Automation Up To 4-5 Degrees, Precision Machined .Until Ti› Del Iver Initial, System Wide Compr Ess Ion, Wide Proxijr Alro Distal Jaw Aperture ( Proximal8mm Distnl 22Mm ) 3 Point Gap Control For Alignment Andcalibral + On Throughout The 60 Mm Stapl Eme, Knife Direction / Reverse Control To Dasconfinue The Fjring And Return The Kn Jfe, Interclaarpcable 6 Row Cartridge Optsons Of White, Blue , Gold, Green And B1ack, All Bits Down To 12Nun Trocar Sleeve, 440 Mm Shaft Length- 60 Mm Stnpler , Ljnear Cutter É Smirwith Sjx Rows, 3D Staple Fourateon, Option Ofegosed Stap1cheight Of I.3Jnm / 1Si13ji1 / 2Mmin One Cartridgc Only , Linear Either 75Mmwrite Six Roy>, 3D Staple Lfirmatioy Optioja Of Closed Staple Height O1 1 .5Mm / 1.8 Inns / 2Irm In One Cartridge Only , Universal Incur Cuter Carbndge 75Mm Open Linear Cutter Compafible With Selectable Staple Heinit 1 Inear Cutter 75Mm.Option Of Closed Stapl E Heignt Ofi.Jmm1 8Mm / 2Irrain One Cartridge Only6 Rows 3-D Staple Technology , Universal Linear Cutter Cartridge Simm For Open Iinear Cuttercompatiblemath Selectabie Staple Heigla R 1 I Near Cutter 35Mm. Option Of Closed Staple Height Of 1A Rirrj .8Mrm‘2Mrirone Cartridge Only6 Rons 3-D Stapl C Tcelanol Ogy , Curved Cutter Stapler 40Mm Linear Cuttur Simultaneous Cutting And Stapling , Curved Green Cartridge Havjrg Close Staple Hejght Of 2.0 Mm. Tactile Feedback On Completion Of Fring Scqiemce New Anvil Knife With Every Catridge , Powered Circular Staples 29 Mm With 3D Stap|E And Not Slip Grip , Poweredcircular Stapler 31 Mm With 3D Staple And Not Slip Grip , Circular Stapler 33Mm Cth Connolledtissue Compression With Adjustable Stapl E Laeigjnt ( 1.0-2 5 Mm Mm Controlledtissue Compressi On, Longer Staple Leg 5.5Min & Non St Ip Grip Surface , Laparoscopic Cartndge For Stapler60 Mm Blue, 1.5 Mm Closed Staple Height With Gripping Surface Tec!I Nology And Six Rows Compatible With All Range Otendosopic Linear Cutter 60Mm , Laparoscopic Cartridgefor Stapler With Allrange Of Endoseopj C Liaaear Cutter 60Mm , Pph Stapt Er 33Mm - Hemorrhoifial Stap ] Cr Kit Consjsts Of 33Mmheirorrhoidalcircular Stapt Er ( With+ !Ged Anvi ] Adjustab E Closed Staple Height From 0 75 Mm—1.5 Mm Stapte Open Leg Length Of 5 5 Mm ) . Suture Threader, Ci Cul Ar Ana1 Dilator. Purse-Stnng Sulure Anoscope, Suture Tor Purse String. , Optically Gujded Bladeless Trovar12rnm With Bilateral Tissue Separators, Opticaj Tip Lo Eliminate Blind Entry, Clear Ubbed Cannula To Enhance Abdominal Wall Retentiori. Recessed Siopcock Valve. Funnelshaped Housing, Duckbill Seeondary Seal, Inteerated Universal Seal That Eliminates The Use Of Reducer, L50mm Length. , Optically Guidedbladeless Trocar 12 Mm With Bhateraltjssue Separatoy Plieaitp To E } Im Nate B ] Ind Ejtrv, Clear Ribbed Canntila, Recessed Stupcockvalve, Funne { Shapcdhouslngduckbill Secondary Sep Integmtcd Univers Tj Sla ] That E ] Rp } #Atc3 The Use Of Refiucer 1Engtl100mm. , Faeial Clqsure Device Contain - Optical Bladcjess Trocar With Tact Al Closure Der Ice Co Raptible With Cleüi_Annula Have Two El Dc Opening Meant For Uniform Port Clostire , Varied Staple Height Reloads / Cartridges Herr 60 Mm Giairstruinenls With Tri-Staple Technology, Weth The Cutting Knije Blade Incorporatedin The Relouds Itselfwith Purple Vaned Staple Beigfit Of 3, 3.5 And 4Mmleg Lenen , Varied Staple Height Reloads / Cartridges For 80 Mm Gia Instrumentswith Tri-Stapte Technologywiththe Cutt U Knite Blade Lrieorpomled In The Reloads Itself, With Purplearied Staple Hcjght Of 3, 3.5 And 4Mjn Leg Leng£A , Linear Cutter With Varied Staple Height, Tn-S Taple Technology-Enabled Reloads Integrntionwig 1 En Anc| Right Firing Kncb ( Both Side Firings , Linear Cutter Stapler W Us Integratedgap Control Tecbnol Ogy Iz 60 Mm Tnstaple Gia Stapl Ci . Compatible With Tri- Staple Gia 60 Min Open Lmear Cutterreloads / Cartridges Purpule And Black , Eea Circular Stapler Purple Colourmediumthaci‹ , Triple Row› With Tristaple Technology ( Three Rov Of S To [ De Inner To Outer Row 3.0, 3.5 And 4 0 Mm With Sloped Cartridges Face In One Simpler ) Diameter 31Min , Linear Cutter With Varied Staple Hejght, Tri 8Taple Technology-Enabled Reloads Integrationwithleft Andright Firing Knob ( Bog Side Fireng ) , Iinear Cutter Stapler With Integratedcap Control Technology In 50 Nun Thstaple Gia Simpler. Compatible With Tri- Staple Gia 80 Mm Open Linear Cutterreloads / Cartridges Purptd E An Black , Wound Protector With Doubie Ring In Small 2 5-6 Cmusfda Approved , Wound Protector With Doublering In Medium 5-9 Cm , Woundprotecior With Double R Infin Larc E In Size 9-14 Cm Usfda Approved , Endo Batch Specimen Removalkit With Continuous Ring , Polyurethane Pouch Witli 34.5 Cm Shaft Lenth 10Mm With Leakproof Andimpervious Material To Cancer Cells Of 0.5 Microns / Pretied Purse Sbing On Pouch Usfdaapproved , Disposable Laparoscopic Clipapplier Preloaded Vzth 16 Clips, 5Mm Diameter With C Up Logictechno›1 Rug And Digital Display Titanium Clips- U Shaped , Laparoscopic H Oer Cutrerwithout Integratedfresh Knife With 360‘Rotatlon& 0-45* Articulatjonin Both Direction For Use With Cartridges In Sizes Of 30Mmcapable O1 Loading  I Length Camidges On Same Gun Onlv , Lnparoscopic Liner Cutterwithoutntegrated Fresh Krife With 360*Rotation & 0-45* Aiticulatio, Ain Both Direction For Use With Cartridges In Sizes Of 45Mmcapable Of Loading All Length Cartridges On Same Gun Only , Laparoscopic Liner Cunerwithout Integrated !?Esh Knife With 3Fi0*Rotation & 0-45* Artlculatiorin Laotla Drection . For Use With Cartridges In Sizes Of 60Rnm Capable Off Oading Ai1 Length Cartridges On Same Gun Ody , Hand Activated Cum Ed Taper Up Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device 9Cm Lengtla, 16Min Curved Active Blade With Adaptive Tissue Teclinol Ogy Cafable Of Sealmg B1ood Vessel Up To And Including 5Mm In Diameter, With Ergononic Symmeoiealburgerring Gyip- Focus 9 , Hand Acnvated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coaguiatiojadeviee, 17M Lengtla, 16Inmcurved Activebladevilla Adaptive Tissue Technology Capable Of Sealingbloofi Vesselsr+ Pto And Incl Nding 5Mm In Diameter. With Ergonornj C Symmetrical Finger Ring Gnp - Focus 17 , Advance Bipolar Hand Activatedprobe With 5Mm Shafi Diameter And 35 Cm Shaft I Engtla Vnth 5 Mm » Ide Stmaght Jaw Design With Seal Length Of 20Mm And Cul Length O1 ] 6Mo, Seai Ing Yesse1 Upto And Jncludjng 7R3m Through Ua3 J:Tj-Eqtjency Energy And Leaving A Temperature Controlled Mechanism Within The Jaw And Having Ar0culation Of 1.10 Degrees O Degrees On Both Sides ) And Capabl E Of 360 Degrees Rotauon , Advancebipolar Hand Zyctivatedprobe Wnh 5Mjn Shafi Diameter And 43 Cm Shaft Length With 5Rm ›I De Straight Jaw Design With Seatlength Of 20Min And Cut Lens Of 16Mm, Sealjngvessel Upto And Including 7Min Groughraw I O Frequency Energy Anb Having A Temperaturecontrolled Mechanism Within The Jaw And Having Articulation Of 1.1.0 Degree { *O Degrees On Both Sides ) And Capable Of 360 Degrees Rotation , Advance Bipolar Hand Activatedprobe For Open Surgery With 3Inm Shafi Diameter And 20Cm Shafi I Ciazth, 6Mmnude Straight Jaw Design Cth Jaw Length Of 38 Mmsealing Vessel Upto Andincl Nding 7Marthroughradio Frecuency Energy , Irving Separate Seal And Cut Buttons, Capable Of 360 Degyees Rotation , Laparoscopic Shears 5Mm Diameter.36Cm Long, 15 Mm Curved Coated B1ade And A E ] Amp Arm With Use Ue Pad, Capable Of Cutting, Sealing, Grasping And Coaeulating Blood Vessels Up To And Including 5Mmin Diameter. 360 Degrees Rotation, Ergonomic Handle Compatiblemath Ulu-Leonie Energy Source And Capable Of Hand And Foot Activate On , Advanced Bipolar Tissue Sealer 25 Cms, With 5Mm Shatt Diameter, 24 Mm Jaw Length, 21.8 Mm Cut Length And 13.4 Mm Jaw Aperture Designed For Use Iropen Surg Ccl Procedures With Curved And Tapered Tip And Uses Aradvancedjgorithm For Intelligent And Efficient Energy Deñverydevice To Leave Intuitive Design With Separate Seal And Cut B C+Ti On And 360 Degree , Advancedbipolar Lssue Sealer 37 Cms, Math 5Minshaft Diameter, 24 Mm Jaw Length, 21.8 Mm Cut 1 Enill And 13.4 Mm Jaw Apernire Designed For Use In Laproscopi C Surgical Procedures Vith Curved And Taperedtip And Uses Sja A‹I Vanced D Goiiwmfor Intelligent Andefficient Energy Del J›Ery. Device To Have Intuioie Design ›Vjth Separate Seal Ajad Cut Bu1i‹›R And 360 Degree , Advanced Bipolar Tiss We Sealer 45 Cm With Sm Nshaft Diameter, 24 Mmjaw Length, 21.8 Mmcut Fen _I1and13.4 Mm Jaw Apemue Designed For Use In Laproscopio Surgi Catprocedureswith Curved And Tapered Tip And Uses An Advanced Algorithmfor Intepjgent Andefficient Ethers Delivery . Device To Have Intuitive Design With Separate Seal And Cut Pinion And 360 Degree Continuous Shaft Rotation , Laparoscopic Shears Drum Diemeter›36Cra Long, 18Mir Curved Coatedb1ade Und A E|Ainp Arm Y7th Tissue Pad, Capable Of Cuttmg, Seh Ing, Erasping And Coagulating Biood Vessels Up To And Incl Ufi Ing 7Mm In Diameter. 360 Degrees Rotaeoy Advance Hemostasis Handactivafionmode For Seatrig Vessels Upto 7Mm In Diameter , Ergo Ao Me Handle Co Opali L^ Ie With Ultrasonic Energy Source. Capable Of Hand And Foot Activatnorvith An Integratedhand Piece And Trnrsd Ucer , Connecling Cattle For Ultrasonic Harmonic Scalpelfor Openenergy Probes Compatible With Fucus Plus Shear- Hp Blue , Connectomgcable For Ultraronic Harmonic Scalpel For Lap Energy Probes Compatible With Ace Plus Shearhp054 , Laparoscop C Shears 5 Rmdiameter.45Crntory I 5Mm Curved Coated Bbade And A Clamp Arm With Tissue Pad, Capable Of Cutting Sealing Grasping And Eoagulatingblood Vessels Up To And Including 7Mm In Diameter 360 Degrees Rotation Advance Hemostasishand Activationmode For Scaling Vesselsupto 7Mm In Diameterergonomic Handle Compatble With Ultasonicenergy Source And Capable Of Handandfoot Activation , Nasalhaeirostatic Sponge Pack ( With Airway ) 10Inch , Platt›Np For Max Llary Swrig And Mandlb Mar Fixation Surgeries ( Titanium ) Plates - 2 Mm Thickness ( 22 ) Holedril1 Bit Machinc With Insertion Tools , Plaiting For Maxillaryswing And Manfiibt+Lar Fixate On Surgeries ( Titanium ) Plates - 2 Mm Thickness ( 1 *2 ) Holedrill Bit Machinc With Insertion Tools , Plaiting For Maxi Ilary Sving And Mandibular ?Ixatj On Stcgeries ( Titanium ) Plates - 2 Mm Thickness ( 1* 1 ) Holedrill Bit Machine With Insertion Tools , Plattinp° For Ar Axillary Suing And Mandibular Fix.Ation Surgeries ( Titanium ) Screw- ( 2 Mm ) Diameterdry11 Bit Maqbine W¡Th Insertiontools , Plattinp° For Ar Axillary Suing And Mandibular Fix.Ation Surgeries ( Titanium ) Screw- ( 1.5 Mm ) Diameterdry11 Bit Maqbine W¡Th Insertiontools , Pbatting For Maxillary S Vj Rig And Ir Aiadibular Fixatj Orj Surgenes ( Titanium ) Screw- ( 2.5 Mm ) Dian Eterair + Ii Bi1 Machine With , Plotting For Maxillary String And Mand Ibular Fixation Surgeries ( Ltariium ) Screw- ( 3 Mm ) Diameter Dr I11bit Machjne With Insertiontools , Speech Prosthesis For Laryngeetom } ( Indwelling Lowresistance Silicon Voice Prosthesis Wed Diamelerwith Varied Length Should Have Blueefion Valve Seet Lor Privacy And Secondaiy Iilsedion Alone With Inserting Toojs And ‹-Icaiirg Accessories ) 7Fr ( 4 Mm ) , Speech Prosthesis For Larynpectoary ( Indnel1ing Toe Resistance Silicon Voice Prosthesls Varied Djarnete R With Variefilength Should Have Blue Teflon Value Seet For Pri Ray And Secondary Irsertion Along With Inserting:Ools Andc Leuning Accessories ) I7fr ( 6 Mm ) , Speech Prosthesis For Laryngecto Ry ( I Ndwellinz 1Owresistance Silicon Voice Prosthesis Varied Diamc Ict With Vatied Length Shouldhave Blue Tell On Halve Seet For Pr Mary Anrl Secordary Insertion Along With Inserting Tools Andc Leuning Accessorj Es ) J 7Fr ( 8 Mm ) , Speech Prosthesis For Laryngectoiny ( Jpduelljng Lowresistance Suf Icon Voice Prosthesis Varied Diam Sterstb Vr Ed Length Shouldhave Blue Teflon Valve Seet For Pn Mary Anfi Secordary Insertion Al Ong With Inserting Tools And Steuning Accessories ) 17Fr ( 10 Mm ) , Speech Prosthesis For Laryngectomy ( Indwelling Owresistance Sii Con Voice Prosthesls Van Ed Diajretestb Wed Length Should Have Blue Teflon Valve Seet For Primary And Secondary Lrsertion Along With Inserting Tools And Cleuning Accessories ) 17Fr ( 12.5 Mm ) , Speech Prosthesis For Laiyngeotoiny ( Indwellmg Totrcsistance Silicon Voice Prosthesis ›Aricd Diameter With ›Ariedlength Should Have Blue Teflon Valve Seet Tor Priinary And Sccondary Insertior Along° With Inserting Tools Andc!Eaning Accessories ) 20Fr ( 4 Mm ) , Speech Prosthesis For Laryngectomy ( Andwelling Los Icsistance Silicon Voice Prosthesis ›Arjed Diarnete R Wrth Varied Length Should Have Blue Tetlon Valve Seet For Primary Anfi Secondnry Mserlon Al Ong With Inserting Tools Anfi C!Eaning Accessories ) 20Fr ( 6 Rum ) , Speech Frsthesis For Larynqectomy ( Indwelï Illg Losren1stance Sllicon Voïcg Pro6thesls Van Ed Diam 0 Tenwith Bedlength Shouldhave Blue Teflon Valve Seet For Primary Anfi Secondary Insert On Along Vnth Inserting Tools Anfi C Leuning Aecessories ) 20Fr ( 8 Mm ) , Speech Prosthesis For Laryngeclomy ( Indwelling Lowresistanee Silicon Voice Prosthesis Varied Diame Le: With Varied Length Should Have Blue Teflonvalve Seet For Primary And Secondary Insertion Alonsruth Jnserting Tools Andcl Caring Accessories ) 20Fr L0 Miv , Speech Prosthesis For Laryngectomy ( Indwelling Lowresistance Siliconvoice Prosthesis Varied Djarneter With Varied Iengt5 Should Have Blue Telon Valve Seet For Primary And Secondary Insertion Alone Cth Insernng Tools And Cleaning Accessories ) 20Fr ( 12.S M M ) , Speech Prosthesis For Laryrigectomytardwelling 1O Vresistance Sillcon Voice Prosthesls Izrieddiameter With Varied Lengm Slaouldhave Blue Tepon Valve Seet For Priinary And Secondary Insertion Aloups Ruth Inscrting Tools And Clcaning Accessorics ) 22.Sfr ( 6 Mm ) , Speech Prosfhesis For Laryngectomy ( Indweii Ing Lotresisiance Siljcon Voice Prosthesls Varied Diametct With Varjed Length Shouldhave Blue Tel On ›Alve Seet For Priinary And Seconday Insertion Along Math Insertù 6Tools And Cl Uaning Aecessories ) 22.Sfr ( 8 Nm ) , Speech Prosthesis For Laryngectomy ( Indeelling Howresistance Siltcon Voice Prosthesis Varred Djameter With Varied ] ;Qgt } J S£Oiild Have Blue Teflon Valve Seet For Pu Tiaryanad Secondary Insertionalong With Inserting Tools And C1 Eanîng Accessorjes ) 22.Sur ( 10 Mm ) , Speech Prosthesis For Laryngectomÿ ( Irdwellil7g Lowresistance Siiicon Voice Prosthesi9 Taried Diam Ever With Varied ] Ength Shotildhave Blue Tefion Valve Seet For Prîmarysud Secondaryinsertion Al Pu P Wit ] Jnsertjng Top ] $ Ajjd ] Est Jjjg Accessories ) 22 Sfr ( 12.5 Mm ) , Spàech Prosthesis For Laiyngeclomj ( Indwell Ing Lowresistance Sj Picon Voice Prosthess Varied Diat Eler With Varied Lergth Sloutd Kave Blue Teflon Valve Seet Foi Pnmary And Secondary Msertiriralong Withinsening Tools And Clesning Accessories ) 22.Sfr ( 4 Mm ) , Blockused In Divropjasty ( Sialestic And Aortes ) 70*5F ) Mjr With 20 Mm Thickress , Disposable Needle 16G X Iinch , Cuivedtip Œ Stepped Cartridges Face |°Roin Inner To Outer Side 2.0.2 5 And 3.0 Mm Staple Heights Roy.For Variable Thickness Tissue Application Fixed Anvh , Differentleg Length Staples In Sam E Cartridge , Inbuilt Kjjife , Size 45R ›Tan Colour Code For Vascular Appcations , Curvefi Tip & Stepped Caitridges Face From Inner To Outer Side 3.0, 3.5 And 4.0 Mm Slaple Heights Ron For Variable Thiekness Tissue Appllcatj On › Fred Anvll , Different Leg Length Staples In Salue Cartridge , Inbuilt Kuifc , Size 45Rrpurpule Coiour Code For Medaum To The Ck Tissue , Varied Stapl E Hei%T Reloads / Cœtridges Lör 60 Min Gja Instrumentsruth Tu-Staple Techrology, Will Tlac Cutting Knafe Blade Incorporatedin The Rcioads Itself, With Black Varied Staple Height Of 4, 4.5 And 5Mmleg Length , Disposabje Laparoscopic Chip Ayp1ier Preloaded With 16 El*Pu, 5Inm Diajneter Wilh Chip Logictechno T Oey And Digital Display Fitanium Clips- U Shaped , Synthetic Oxidised Re-Generated Cellulose Double Lavered With Peg And Trîlysine Size 2*4Cm , Synthetic Oxidised Re-Generated Cellulose Doubt Eayered Wilh Pfg And Triljsine Size 5* 10Cm , D Sjaosab Ie 10 Mm Lr Doscopic Clip Applier Wltlafacility Of Loading Clips Independent Of The Firing Mechanism. , Disposable 10 Mm Endoscopic Clip Applier With Facility Of I Oading, Clips Independent Ot The Tiring Mechanism Large Size , Endo Liner Cutternuthout Integratedfresh Knife Math 360*Rotation & 0-45* Articnationin Both Djrec1i‹A+Afor Use With Cartridees In Sizes Of 30Inm Capable Of Ioading All Length Cartridges On Same Gun Only , Endo Liner Cnnerwithout Integatefifresh Kni Fe With 360*Rotation & 0-45* Articulationin Both Direct Ionfor Use Cth Cartridges In Sizes Of45mm Capable Of Ioadine All Length Cartridges On Sabre Gun Only , Endn Liner Cutterwitllo Ut Integrated Fresh Km Be Math 360*Rota0on & 0-45* Articulationjrboth Direci I‹Ra For Use With Cartrj Dges In Sizes Of 60Mm, Capabj E Of Loadin° All Length Cartndges On Same Gon Only , Disposabj E Clip Appl Ier Preioaded With 20 Cf Ipssupernterlock Security With Clip Designtechjaologymedium , Disposad Ie Clip Appd Ier Prcloaded Rjth 20 Cl Jps, En Periisierlock Securjtx With Clip Desk Untecfinolorsmal , Sterile H Poderm Ie Syringe Wrth Needle Attached 22G. Single Use -2 Ml , Sterile Hypodcrmic Svr+ A Ce With Needle Attaehed. 22G. Single Use -5 M1 , Biolomcal Glue With Ihroinbm& Aprot N C1 Ml , Biolomcal Glue With Thrombin & Aprotinin 2Mi , Closewound Drainage Device Under Neative Pressure ( Closed Wound Suction Unit ) Size 8 No , Closewound Drainage Device Under Neative Pressure ( Closed Wound Suction Unit ) Size 10 No , Closewound Drainage Device Under Neative Pressure ( Closed Wound Suction Unit ) Size 14 No , Closewound Drainage Device Under Neative Pressure ( Closed Wound Suction Unit ) Size 12 No , Sterile Oxidized Regeneratedcellulose Hemostatjng A°Entin Neiform Fibrillar Andin Thick Sheath As Perip , Urine Collective Bag, Disposable 2000 Ml With Urollow Meter , Central Neck Line- Double Lumen ( 3 Nobe1 Metal Coated ( Gold, Silver, Pa11adiurn ) Central Lumen Catheterb Oubl E Lumen ) , Microcatheterselectlye Infusionmicrocathetcrs For Intra Cmnia Aneurysmtreatmentwith 2 Tipmarkers , Microcatheter Selective In Fusion Microcatheters For Deployingintracranial Device. Stent Deployment , M Crocatheicrselective Infusionmicrocaiheters For Flow Diverter Delivery With Single Tip Markers 0.027 Inch , Microcatheter Flow Dependent Super-Set Eetive High Flow Infusion Mierocatheters For Cerebral / Spiralavms ( Compat Bie With Dmso ) , Micro Guide Wirefor Mierocntheiershapabj E Distal End Aridvvlh Torque 0 014Inch , Bare Platinumcoil Complex Shape. Sotf, Electrolvie Detachable Frarn Jnq And Filling Size 1 To 25Mm , Bare Platmurn Coil Complex Shapesotl Mechanically Detachable Framjnq And Fi1line Size 1 To 25Mm , Bare Platinum Coil He ] Ical Shape. Sofg Electrolvt4 C Detachable Size 1 To 25Mm , Bare Platinum Coil Helical Shape. Sob Mechanicallydetachable Size 1 To 25Mm , Aortic Punch 2.5 I Eugth Berwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cm Edge For Cream Precise Removal Of A‹En C Tissue Conicaltip Or Round / Eiiptjcal Tip For Easy Insertat Orby Straight Or Button Hole Tech, Shoulfi Have Long And Short La° Ridge Confirguaratior, Sterile Packing Size 2.5 , Aortic Punch 3Length Betnwen 6 To 7 Mídlength Diamondedge Sharp, Dual Ent Edge For Clean Precise Removaj Of Aorta C Tissue, Corical Tip Or Round / Eljplcal Tip For Easy Inseihtionby Sbai%T Or Button Hole Tech, Sbould Have Long And Short Laudle Confirguanuon, Sterilc Packtng , Aortic Punch3.5 Lenyth Betwwen 6 To 7 Midjength Diamojid Edee Sharp, Dual Cut Edge For Clean Precisc Removal Of Aortic Tissue Conical Tip Or Round / Elipticajtip For Easy Msertationby Straight Or B Utton Hole Tech, Should Have Long And Short Tia+ Idle Confirguaratiol . Slerile Packing Size 3.5 , Aortic Punch4 I.Ength Betwwen 6 To 7 Midlengthdiamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of A Tarnc Tissue, Conical Tip Or Round / Ehptical Tip For Easy Irsertationby Straight Or Button Cole Tech, Should Have Long And Shorthandle Confirguaraton, Sterile Packing Size 4 , Aortic Punch 4.5 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aor I Ie Tj Ssue, Conical Tip Or Round / Eliptical Lp For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Late Idle Confirguanuor, Sterile Packing Size 4.5 , Aortic Punch 5 Lengthbetween 6 To 7Midlength Diamond Edge Sharp, Dual Cm Edge For Clean Precise Removal Of Aortic Tissue, Come Tip Or Round / Emptiest Tip For Easyq Insertation By Straight Or Button Hole Tech, Should Have Long Arnd Short Handle Corfirguaration, Size 5 , Aortic Punch 5.5 Length Betvnen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aoruc Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insermtion By Smught Mr Button Hole Tech. Should Have Long And Short Handle Confirguaratj On, Size 5.5 , Aortic Punch 3.6 Lengthbetwven 6 To 7 Midlength Diamondedge Sharp, Dual Cut Edge For Clean Precise Removal Of Ao Rite Tissue, Conical Tip Or Round / Eiipiical Tip For Easy Insertationby Straight Or Button Role Tech, Should Have Long And Short H‹ Ndle Conf-Ir5uamtion, Sterile Packing Size 3.6 , Folleys Catheter Fixation Divicc Foley Catheter Holder Universal Size Shouldhave Leg Band And Is Disposable Single Patiemnt Use Dev Ice S Mould Have Catheter Grip Of 18 To 24 Mr Catheter And Made Of Crobelt Or Any Other , Tur Set Tur Irrigation Set Disposable Urology Instmmenturology Equipmeni Endosurgery, Mfg Fromclínica Grade Non Toxic Medical Trasparent Pvc Sheet, Y Sbaped Connector Vntb Poirnted Spike To Easy Erce Fiacilities A { Te1 Ual Ive Change Solution Thumboperated Clamp Smooth Change Of Bottle Proximal End Fitted With Flexible Latest Tubing For Easy Connection To Endoscope Eto Steril Individual Pack Should Have Minium Langht Of 260 Cm Or More , Laproscopic Port With Trocar 5Mm Optimally Guided Bladclcss Irocar Drume Ithbilateraltissue Separators, Optical Tip To Eliminateb I + I Ic4 Entry, Clear Ribbed Cannula To Enhance Abdominalwall Retention, Recessed Siopcock Valve, Funnel Shaped Housing. Duclcb I! I Secondary Seal, Inteerated Universal Seal That Clim Mates The Use Of Reducer, L50mm Length. , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Shouthave 20Mm Sample Notchand Thin Wall Cannula For Larger Core And Echogenic Making On Both So Let Tip And Carinul A For Improved Visibility During Procedure. Should Ha› E Three Programmablefiring Mode-Automate Rn‹›Dcdelay Mode And Zero Throw Mode. Should Have 1Vo Firing Bttor On Surface Of Thesize12g, 14G, 16G, 18G, 20G With Length 11Cm 15Cm, 20Cm. Shoud Come With Comp Tib Ie Coaxial Packed With Biopsygunusfda Approved , Patient Pre Operative Skin Preprationsolution 26 Ml In One Stop Sterile Applicator Container For Single Use V Ith 2% Chiorohexdine Gluconate ( Chg ) And 70% Ipa With Orange Tint Colour Or Easy Via Ulization, Us Fdaapproved , Rem And Non-Remsingle Use, Corded Patient Return Electrodesconductive Adhesive Hydroge With Usfda , Chiorlaexidjne Impre°Nated Paraffin Gauze 30X10cm , Chiorlaexidjne Impregnated Paraffin Gauze 15X1 Roll , Surgical Crloves 6.5 Non Latex Surgical °Io›Es Synthetic Polyisoprene Povder Free Overall Length 283Mm With Puncture Indicator Technologyusfda Approved , Surgical Gloves 7 Non Later Surge Cal Gio›Es Synthetic Polyisoprene Powder Free Overalllenglh 283 Mm Withpnurture Indicator Technologyusfda Approved , Surgical Gloves 7.5 Non Later Surp°Ical Gloves Synthetic Polyisoprenepowder Free Overall Leneth 283 Rum With Puncture Indicator Technologyusfda Approved , Ionic Silver Dressings With Broad Spectrumantimicrobial. Bactericldal, Biofilm Destruction& Reloc Ii Ion Efficacies Recommended For Low To High Exudingvounds5 Cms X 5 Cms , Ionic Silver Dressingswith Broad Spectrumantiinicroblal, Bactericidaf, Biofilrndesbuction & Reform Na:Ion Efficacies Recommended For Low To I-Iagh Exudingwounds10 Cms X 10 Cms , Self Adherentmoist Wounhdress N°Made Up Of Triple Hydroeojl Oid Matryelastornerjc Polymer F O R 1°Ressure Ulcers / Bed Size 10 Cms*10Cms , Sfch Bondedhydroftberburns Oressslngs With 1.2%• Impregnatedtoclc Silver With Sustained And Oi4 Tlelnand Broad Spectrum Antimicroblal & Bactricidal Activity With Highexudate Management Capability With A Wear T Ime Of 21 Days & Locking In Edudates In Gel Form 23 X 100 Cms , Double Wallresuscitator With Pefip Valve In Adult It Should Be Fuhy Autoclavabledouble Wall With Hand Strap It Shout Dbe Supplied Cth Autoclavable Reservoirbag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult Bag Volumemark Iv ( 1300 Ml ) Eightadult ( 415 G ) It Should Be Us-Fdace & Iso Cerified , Double Wall Resuscitator Mtbpelp Valve In Paediatrics It Shoulfi Be Fully Autoclavable Double Well With Hand Strap It Should T›E Supplied With Autoclavable Reservoir Bag It Should Have A Single Shutter Valve System Made Of S+1Icone Rubber It Should Have Easy Attachment Of Peop Valve Forpeadiatric It Should Hsve Provision To Attach Rnanoineteitor Paedlatricsambr Bag Bag Volume:Mark Iv Baby ( 300 Ml ) Weightbaby ( 190 G ) It Shouldbe Us-Fda, Cfi & Iso Certified , Sin%E Patientuse Sebshesuscitator ( S Pur Ii Cth Peep Valve In Adult } • It Should Be S1n%E Use Resuscltator Made To Sebs Material Not Pvc • } T Should Laai C Unique Singh.$ ] Uitter Va [ / E System For Rellabie Functional Iy& Swivgl Tietween Vat¥E And Mask Permits 360° • Ït Shoutühave Thin-Naïleó Compresstonbag Y‘Ith Adstrip. • Resusc Tarot Volume. Adult ( 1475 Mï ) • ( Including Reservou And Rnask ) • It Should Be Ce / Iso, Us Fda Certitied. , Single Patient Use 8 Ess Resuscitator ( S Pur 11 With Peep Valve Inpaed ) • It Should Be S N%E Use Resuscitator Made To Sebsmaterial Not Pvc • It Should Hase Unique Single-Shutter Value System For Reliable Lfictionality & Smvelbetween Valve And Maskpermits 360° Positjoning In Relation To Thepatient • It Shoulfi Have Thin-Wall Efi Compression Bag Vith Send Sap.It Should Ba›E Provision To Attach Manorn Elcr F0r Paedialries • Rssuscitatorvolume Pediatric ( 635 Ml ) • ( Inc1uüing Rc.Seaoir And Inask ) • It Shouldbe Úe / Tso, Üs Lda Con Ted. , Fi Jrgle Patientuse Sebs Resuscitator ( S Pur 11 With Peey Valve In Neo Fatal ) • { T Shou } D Be Sjng } E Up Tesuseitetormade To Sebs Material Not Pvc • It Should Nave Uni Que Single-Shutter Val›E System For Reliable Functionality & Sv4veibetweenvalve ‹Ijjumaskperm Its 360° Positioning In Relation To Bepaoent • It Sho Uid Leave Thin-Was Led Compressionbag Cvi Tb Handstrip • Resuscitator Volumeneonate ( 220M1 ) • ( Including Reservo R Andmasjc ) • It Should Fe Ce / 1S O, Us Fda Certified , Pre-Formedsga With Gastric Access & Inuibation It Shout D Be Latex Free Preform Ed Laprgcai Mask Having Gastric Access Charmedand Should Be Usedas Cconduitfor B Irect Endosacheaiintu Bath On With Any Bardetj • It Shouldbuilt-In, Anato Ricahy Cprrect Curve And Cuff & Tube Mouldedas A Singje Unit. • U Itra-Thin Pilot Balloonwithtactile Indication Of Degree Of Inflation. • Universali5mm Connector ( Iso ) . • It Shout D Be Cl / Is 0 Us Fda Certified , Pre-Forme‹J Sga With Gastric Access & Intubation It Should Be Latex Free Preformefilaryneealmask Having Eastric Access Channeland Should Beused As A C Onduit For D Jrect Endotraclaeal Intubafion With Any Brand Ett • It Shouldbujlt-In, Anatornically Correct Curve And Cuff & Tube Moulded As A Slrgl E Unit. • Ukm-Thin Pilot Balloonwith Tactile Indication Of Degree Of Inflation. • Unnersall5mrnconnector ( Iso ) . • It Should Be Cfi / Is 0, Us Fda Certified , Pre-Formedsga Cth Gastric Access & Intubation Ft Shoulfi Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Dircc4 Endotraehehintubation With Any Brand Ett • It Shouldbuilt-In, Anatomically Correct Cur E And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Bd 1Ooh With Tactile Indication Of Degree Of Irritation • Universall5mrnconnector ( Is0 ) . • It Shoed Be Cfi / Fs 0, Us Fda Certified , Pre-Formed Sga Mtbgas+Ri C Access & Intubation It Shouldbe Latex Free Preformedla Gearmaslc Havjng Gastric Access Channel And Shpuld Be Usednconduit For Direct EndoRachealmtubati On With Any Brand Ett • Ii Should But ] T-In, Anatomicall5correct Curve And Cult & Tube Inoulfled As A Single Unit. • Ultra-Thinpilot Balloon With Tactile Inb I Catlon Of Degree Of In Station • Universal ] Hmmconnector ( Iso ) . • It Shout D Be Ce / Iso, U8 Fda Terrified , Pre-Tormed Sga Moth Gastric Access & Intubation It Shoril D Be Latex Free Preformed Laryngealmask Having Gastric Access Channel And Should Be Red As U C Onduit For Direct Endotrachealmtubation With Any Brand Ett • It Should Built-In, Anatomicaljy Correct Ewe And Cuff & Tube Mouldedc A Sangl E Unit • L!Loa-Min Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector ( Iso ) . • It Should Be Ce / Iso. Us Fda Certified , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngealmask Havmg Gastnc Access Channel And Shouldbe Used As A Conduit For Direct Endotrachcalintubation Cth Any Brand Ent • It Shouldbuilt-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thinpilot Bai?Oonwith Tactile Indication Oy Degree Of Relation. • Universal 1 5Mm Connector ( 150 ) • It Should Be Ce / Is 0, Ls Fda Certified , Pre-Formed Sga Witlgastric Access & Intubation It Shoul D Be Latex Ftee Prefontedlaryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endoiiaehealirtubabon Wide Any Brand Etc • It Should Bijilt-Iy Anatonncally Correct Curve And Cell & Tube Molded As A Single Unit • Ultra-Doin Pilot Balloonmath Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector ( 180 ) . • It Should Be Ce / Iso, Usfda Certified , Pre-Formed 8 Ga Vzth Gas Ticaccess & Intubation It Should Be Latex Free Preformefi Laryngealmask Having Gastric Access Shame ) And Shouldbe Used As A Conduit For Direct Eodotraclzcal Ntubation With Any Lmndett • It Should Built-In, Anatomlcally Correct Curve And Cuff & *Ube Moulded As A Sjng ] E Unit • Ultra-Thinph Ot Balloonwith Tactile Indicationdegree Of.Njlatj Jj. • Universal 15Mm Connector ( Is0 ) . • It Should Be Ce / Iso, Us Fda Certified , Si Licone F’Re-1Érmed Sga • It Sho Add Be And Autoc|Avab1eup To 40 Times • It Shouldhave Rein Forced Lp At Cur And Cuff & Tube Mouldedas A Single Unit. • Atrauinatj C Insertionaaad Removal • It Should Be Ce / Is 0, U8 Fda Certified , Silicone Pre-Formed Sg A • It Should Be And Autoclavable Up To 40 Times • It Shook D Have Reinforced Lp At Cuff And Cj& Tube Moulded As A Single Unit. • .Atrauiratac Insertion And Removal • It Should Be Ce / Iso U8fda Certified , Siliconepre-Formed Sga Total Size 8 • It Shouldbe And Autoclavubleup To 40 Times • It Showild Have Reinfpreed Tip At Cuff And Cuff & Tube Moujded As A Single Unit. • Atrauiratic Insertion And Removal. • It Shouldbe Ce / Iso, Us Fda Cerbficd , Si ] A Cone Pre-Toured Sga • It Shouj Fibe And Autoclavableup To 40 Limes • It Shoot D Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atrauinatic Insertion And Removal. • It Should Be Ce / Iso, U$ Fda Certified , Silk Cone Pre-Formed 8La • It Should Be And Autocl Avab|E Up To 40 Titres • It Shoal Fi Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Siiaele Ur It. • It Shout D Be Ce / Is 0, U8fdacertified , S Licore Pre—Formed Sga • It Should Be And Autoclavableup To 40 Tjjnes • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Si Nejetin It. • It Should Be Ce / Iso, Us Tda Certified , Siiicone Pre-Formed Sga • It Should Be Andautoclavableup To 40 Times • It Should Have Reinforced Tip At Cult And Cuff & Tube M Ouldecl As A Single Unit • Atraumatic Inserhon And Removal • It Shoulfi Be ?? / Iso, Us Fda Eertified , Si Licone Pre-Formed Sga • It Slou1d Be And Aotoclavableup To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Mo? Dcd As ? Single Unit • Atraumatic Insertionand Removal. • It Shouldbe Ce / Is O, Us Fda Eertified , Ccrvieal Colkir With 12 Sizes Settirgs • It Shouldbe Latez Free A6justable Cojlar With J 2 Size Settinp° In Paediatric Coljar • It Should Have Standard Sizinp° Line For Easy And Aecurate Sizii4g • It Should Be ? E / Iso, Us Fd.A Certifieb , Cervical Cojlar With 16 Sizes Settinp°S • Ll Shouldbe Latex Free Adjusiable Collar With 16 Size Scttjng In Adult Collar • It Should Have Standard Sizlng 11Ne For Easj And Accurate Sizing • It Shoud Be ?? / Iso, Us Fda Cernlied , D Uset Connector Cardlo Secror Electrodes • 1T Should Haye Hiscorductive Wet Gel To Ersure Rellable Traces. • It Shouldbe Desigd With Offset Connector To Prevent Artefactsborn D Srupting The Readouts • It Should Have High Quality Ac / Agc1 Sensor To Ensure Exceheiattrace Qualip • It Should Have Size Not More Than 72 ? 68 Rnrn , Oifset Connector Cardio Sensor Filectrodes • It Shoul D Ha›E High Oonductjve Wet Geito Ensure ??? Iable Traces. • I T Shouldbe Deslgn With Offset Connector To Prevent Artefacts From Disrupting The Reafi Outs • It Shouldhave High Quality Ag / Agclscnsor To Ensure Excel Lent Trace Quality • It Shotddhave Size Not More Thsr 72 ? 68 Mm , Ol£Set Corinector Cardio Sensor Ejeetrodes • It Should Have High Conductav ? Wet Gel To Erisurc Reliable Traces. • It Should Be Design With Offset Corniector To Prevent Artefactsfrom Disruphng The Readouls • It Shouldhave High Quality Ag / Agc1 Sensor To Ensure Excellent Trace 9Ud It • It Should 1+Ave Size Not More Than 72 X 68 Mm , Anatomieal£Ace Maslc With Thumb ???? Silicone •Thumb Rest For ? Tip°Ht, Easy Seaj, Made Up Of Silicone , Moinlcal Face Mask With Thumb Rest Silicone •1Humb Rest For A Tight, Easy Seal, Made Up Of Silicone • Can Be Autoclai Ed Repeatedly At 134°C , Anatomical Face Mask W4ththumb Rest Siiieone •Thumb Rest For A Tighl Easy Seal, Made Up Of Sillcone • Can Be Auioclaved Repeatedly At 134°C , Anatomical Face Maskwith Thumb Rest Silicone •Thumb Rest For A Tight.. Easy Seal, .Made Up Of Si1 Cone • Can Be Autoclavedrepeatedly At 1 34°C , Anatomical Face Mask With Thumb Rest Silicone •Thumb Rest For A Tjgllt, Easy Seal, Made Up Ot Silicone • Can Be Automated Repeatedly At 134°C Size-4 , Aaiatomica I £Ace Mask With Thumb Rest 8I1icone •Thumb Rest For A Tight, Easy Seat, Made Up Of Sillcone • Can Be Autoclaved Repeatedly At 134°C Size -5 , Anatomical Face Mask With Tb Timb Rest Sixcone •Thunib Rest For A Tight, Easy Seal, Made Up Of Si1icone • Can Be Autoctayed Repeatedly At 134°Csize-6 , Disposablesga Anatomical Curve • Itslaould Have Special Curve Mtcarefiillyreplicates Naturalhuman Apntomy • It Mouldeddirectlyinto The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomicallj Gnp During Insertion Size-1 , D Sposabje Sga Latolrical Curve • It Shout D Nave Special Curve That Carefully Replicates Natural Human Anatomy • It Mouldeddirectly Into The Tube • Should Have A D-Shaped Airway Tube To Giyc A Firm And Ergonomically Grip During Insertion Size-1.5 , Dr Z9osay Ie 8 Ea Anatomicalcurve • It Should Have Special Curve That Carefully Replicates Natural La Uman Anatomy • It Mouldeddirectly Into The Tube • Snou1d Have A D-S ] Aped Aimay Mbe To Give A Fine And Ergonomical Iy Grip During° Insertion Size-2 , Disposable Sga Anato Rich Curve • It Should Have Specialcurve That Carefully Replicates Naniral Human Anatomy • It Mouldedh Ireedy Inro The Lube • Should Have A D-Shaped Airway Tube To Give A £Nnand Ergonornical ] Y Grip During Insertion Size-2.5 , Disposable Sga Anatojmcml Curve • It Shout D Have Special Curve That Carefully Rep1a Cates Natural Humananatomy • It Uoulhed Hiyeeti ) • Info Be Tube • Shouldhave A D-Shaped Airway Tube To Gave A Firm And Ergonomically9rip Duringriserl On Size-3 , Disposabie Sga Anatomicalcurve • It Should Have Special Curve That Carcfr4 Ly Replicates Natuml Human Anatomy • It Moulded Directly Into The Tube • Shouldhave A D-Shaped Airway Tube To Give A Finn And Ergonojr I Cally Tip During Insertion Size-4 , Disposabie Sga Anatomical Curve • It Should Have Special Curve That Carefully Reps Icates Natural Human Aj Atojny • It Mouldeddirectly Into Tictube • Shouldhave A D-Shaped Air Vay Tube To Give A Firmanfi Ereonornically Grip Dmng Insertion Size-5 , Disposabl E Sga Anatomicalcurve • It Shout D Have Special Curve That Carefully Replicates Nalurajhuman Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Byway Tube To Give A Fms And Ergonomicallygvip Durmg Inseuion Size-6 , Rhinolaryngo Single Patient Use Slim Scope Insertion Tube Diameter 3 .0Mm Werlcing Length300 Mm Bending Range130 Degree Up & 130 Õeyee Down Field Of View85 Degree Or More Ljirection Of View 0 Degree ( Forward X Jew ) Deplh Of Fiieló : 6—50 Mm O? Better Complete Systemshouldbe U S•Fda And European Ce Certified , Rt??Ojaryngo Sing4e Patient Use Lnvtervenhonscope Channelwjdtja: 2 2Rnan Ihsertj Optube Dá Ameter0 Mm. Working Lengl : 350 Rn M Bending Range 130 Degree Up & 130 Degree Down Field Of View. 85 Dence Or More Drecuon Of View. 0 Degree ( Forward I Îe ) Dept Of Field. 6-50 Mm Or Better Complete Systemshould Be Us-Fda And European Ce Certified , Ultrasorbsap Disposabledrypalis, Guy Pad For Moisture Management, 58 4X90cm, With Breathabl E Layer, Soper Absorbent Core, Aqua Sh C!Úfilm And Qtr Pccreable Back Sheet Absorbency Of 1800-2300Gm, Us Ida / C Eibis Compliant, Iso13485 Compjiant Size-58.4-90Cm , Elstic Head Strap Cannulaspediiatric Et Astic Head Strap Cannulaspediatr+C Must Be Soff Siliconised, Transparent Vjny1; Adjustrii›Lc Elaslic Band For Comfortable, Snug Fit Below The Ears; Complete Lcit With 7-Ft Oxygen Supply Tubingmanuiaclurer Mus1 Ice Us-Fda Registered & Certified Cth En / Eu Is01 348A & Applicable Ûok & Ce Certification. , Over-The-Earnasal Cannula Over-The-Ear Nasalcannula With Star Lumen, So Tubing, Must Be Flexible Contoured Lip Tab Prov Ides U High Level Of Stabi Hty And Patient Comfort. Over-The-Ear Design For A Comfortable And Secure Fit, Brush- And Kink-Res I Slant Tubing. Manalacmrermust Be Us-Ida Registered & Certified With En / Eu Iso 13485 & Applicable 510K & Cicertification , Pediatric Nasal Cannula Pediatric Nasalcannula Softech Wjth Universal Oxygen Connector. 7 Star-Lumentubing Lightweipla 1Flexible Nasal Cannuja Cthstandard Over-Thg-Eardesignedthat Optimizes Fit And Stabil Iiy, Sofi Nasal Prongs Help Max Inize Patient Comfort Individually Packaged For Convenience And Slerility Manufacturermust Be Us-Fda Regîslered & Cert Ji Red With En / Eu Iso 13485 & Applicable 5I Ok & Ce Certi Fication , Infantnasal Cannula Infant Pasal Cannula Softech With Universal Oxypen Connector, 7 S ?Ar-I.U1men Tubing Lightweight.Lie Sible Nasal Cannula With Standard Over-The-Ear Desk Gned That Optimizes Fit And Stability, Soil Nasal Prongs To Help Maximixepatient Comfort. Fijdtydtj@ Y Packaged For Convenienceand Sterililymanufacturer Must Be Us-Fda Registered & Øerl It Redwith En / Eh Iso 13485 & Appsicable 510K & Ce Certification. , Volum Ctric Incentive Spirometer ( Adult ) Volume • C Lneentive 8Piroinete ( Adult ) 4000 Ml With Handle. Olture Measurementm Pt Be Compact Eomfortable Designed To Accommodate Large Inspired Volumesmust Have Good-Better-Best Flow Window &Advujaced, Low Work-Of- Btmthlhqdss1. Particul Ate Flltofsof0o13indevice Houswmust H#Ip To Reduce $K Ofmore } G¡¡ M#Ptpjp9$$Tpg Tpa@E¡D¡S Expandable And Collapsible Tube Must Help Patients Tind Comfortableposition For Treatmentsano Canberemoved Whenstoring The Device. Ergonomicsfivejed Mouthpiece Ahows To Patients Createtight Seatto Enable Not E Accurate Meascteii Ent Flow Mdica*Orwith Smiley Face Provides Visualtarget For Desiredinhalation And Bright Green T4 Ow Ind Icator Make It Easy For Path Ents To See Results. Manufacturer M Ust Be Us-Ida Registered& Certified Cth Fin / Iiu Is01 348A H Appsicabje 5Ion & Ce Certification. , Volumetric Incentive Spirometer ( Pediatric ) Volumetric Incentive Spirometer ( Pediatric ) 25 00 .Ml With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspi Red Volumes.Nlust Have God-Better-Belt How Windy& Adjjjed, Low Z Zk- ( - Breatfmng Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risl Of Foreign Matterpassing To Patients Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments Andcan Lie Removedwhen Storing The Deviceergonomic Swivelecl Mouthpiece Ai ] Ows To Patients Create Tight Seal To Crabie More A‹ Curate Measurement Flow Indicator With Smiley Face Provides Visual Target For Desiredinha Nation And Bright Green How Indicatedjjj@E ¡T Easy { Or Patients Togsee Results. Manjacturer Must Be Us-Fda Registered& Certified With En / Eu Iso 1 3485 & Applicable 310K & , Insplratoryexcrciser With 3 Color-Codedballs, 3 Chambers I Nspiratory Exerciser Auth 3 Color-Codedballs, 3 Chambers & Wide Flow Rate Range From 01 Lf To 1200 Cc / See, With Minimumti Ow Imprinted On Each C1iatr.Her. Most Be Compact Design And Made Of Break-Resistant Plasticmanufacturermust Be Ij S-Ida Registered & Certified Wit.H En / Fiu Iso 134Sf & Applicable 5Iok & Ce Certification. , Adult Mask For Traeheosiorny .Adult Mask For Tracheostomy An.Filaryngeetomy Aerosol Therapy Tubing Connector Must Swivels 360° T‹I R Ease Of Positioning 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing Anfi Nebulizer Teas. Manufacturer Trustbe Us-Fda Registered& Certified Witlen / Eu Iso 13485 & Applicable 510A& Ce Certification , Paediaticmask For Tracheostomy And I Aryngectomy Aerosol Therapyfu Bjng Connector Must Swivels 3Ét!For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacture N Inst Be Us-Fda Registered& Certlfiod With En / Eu 15013483 & Applicable O I 0K & Ce Certification , Elongared .Aerosol Mask Adult Eongated Aerosolmask Adult V4th Under-The-Chin Design For Except Cut Fit On Wide Ran•E Of Face Sizes Ialust Be Clear, Soft Vinyl For Patient Comfort, Ad } Usiabl C Nose Clip Assures Comfortable Fit: Specifically Designedfor Aeros‹›1+ Herapy; Must Be With Suppliedwith 6 Ft. Corr A Flex Corrugatedtubing. Featuring Cuttable Sections Every 6 Intvlan Ul Ccl Urer Must Be Us- Pda Registered& Certified With En / Euis01348a & Applicable Ñok & Ce Ceni Fication. , Elongatedaeroso I Mask Pediatric Elongatedaerosolmask Pediatric Withunder-The-Chin Design For Excellent Fit On Wide Range Of Face +Zes Must Be Clear, Sofi V Iriylfor Patient Comfort, .Adjmtabie Nose Ct Ip Assures Comfortable Fit; Specifical!Y Designed For Aen Isol Therapy; Must Be With Suppl Red With 6 Ftcorr A Flex Corrugated Tubing, Featuring Ciittal Le Sections Every 6 In. Manutaci Urer Must Be Us- P Da Registered & Certified With En / Eu Iso 13Ds5 6C Applj Cable S0 K & Ce Certification , Elongatedthree-In-Oneadult Mask Elongated Three-In-One Ad Not Mask Must Be Able To Use As A Medium-Concentration, High-Concentration ›R Nonrebreathiri° Maslr Uhjch Includes Mask With Flapped Valve, Nonrebreathing Bag Assembly: Adjustable Nose Ct Ip Ass Es Comfortable Fit, Auth 7 Fi. Star Lumen Oxygen Supply Tubing, 750 Rn L Reservoir Bagmanufacturer Must Be U8-Fda :E‹;Istered & Certified With En / Eu Iso 13485 & Applicable 510Ii & Cl Certification , Adult Conventionalsingle Water Ttap Adult Conventional Single Water Trap ( Non-Heated ) Ventilator Circuits Are Avñlabjem A Variety Ofhi Iié Rent Configurations And Styles.Torcorpomle Standard Connectorsfor Use With A Variety Of Ventilators, Ported Wyes Allow } Rcssure Sensing And Temperature Monitoring And Include Tetheredcaps, Au Adult Conventional Circuits With 72 In. Long, Stanjard Ventilator Circuit With Stmight Cormector Inspimtory Limb Water Trap ( For Use With Hmes Only ) . Manufacturer Must Be I*S-Fda Registered & Certified With En / Eu Is0.1.348 O & Applicable 5I 0K & Cfi Certification. , Adult Ventilator Circuit Sincl E Limb Portable Adult Ventilate Circuit Fith Universal Single Limb. Lvlust Be Complete Kit With Rn Am Circuit Hoseexhii1‹Ition Yyve Manifold, Aerosol Hosepatient Elbow Connector. Proximal Airway Pressure Hne, Exha!Ationvaiv• Linea-Jhumidifier 1Im6 Can Facturer Must Be Us-Fna Registereds Certified Cth Fn / Fc Iso 13‹8: & Applicable S I 0K &F Ceni Ft Cation , Adult Ventilator Circul Single Water Trap Adult Convenfional Single M Ateramp ( Non-Hemed ) Ventilator Circuits Are Ayat Labie In A Variety Of Di Târeial Configiratiors And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allowpressure Sensing And Temperature Monitoring And Include Refered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Cjrcuat With Straight Conaaeetor Inspiratoy 1 Emb Water Trap ( For Use With Hmes Only ) Manufacturerrriust Be 1.1 S-Ida Registered & Certified With En / Eu Iso 13485 & Applicable 510K & Ce Certification. , .Adult Conventional Dual Limb Water Trap Adul T Conventionaldual Limb Wmer Trap ( Non-Heated ) Ventilator Circuits Are Available In A Variety R›!Cfi Jterent Configurations And Styles.To Incorporate Standard Connectors For Use V Ith A Vanely Of Venthators, Portedwyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72Iniong, Standard Ventilator Circuit With Straight Connector Dual Limb Inspimtory & Explratoryvater Trap 22Mm Tubije ( For Use With Hmes Only ) . Manufacturer Must Be Us-Fda Registered & Certifiedwith In / Eu Iso 13485 & Applicable 51 Ok & Ce Certification , Hifantprong Cpap Cannula Infant Prong Cpap Cannula Nasal Size 0 Wjth Designed To Recluse Trauma Assocjated With Delivery Of+ Ni Ant Nasal Cpap Must Be Sold Siliconised, Anatomically Curved Prongs To Enhance Fit. Luer Fi Tiing On Expiratory Connec I Or To Allow Proximal Airway Pressure Monitoringeach Set To Include, Soft Siliconisedcannula Lnsplratory & Ezpiratory Ct1 ‹ W Connector; Knit Cap; Two 6 M. Book Arid Loop Fastener Sections; Two 10 To 7.5 Mm Adaptors. Manufacturer M Ust Be Is-Ida Registered & Certified With En / Fu Iso 13485 & Applicable 5 } Ok ‹Ce Certification. , Fhme Head And Morsure Exchangersv / Ith Bacteria Viral Filters Bacterialf Iilration Efficiency & Gt. 99.99 % And Viral Filtration Efficiency & Gt 99 9999 % Filterr Membrane Should Be Of A Hydrophobicron-Roverpolypropylène Material. Sliould Be Tailorcd To Meet The Specjtic Needs Ofbotb Anaesthcsia And Intensive Care , Tracheostomyh Me. 1 Heat And Moisture Exchangersfor Spontaneouslybreathine Tracheotomypatients. 2 Should Ñave In Budt Oxygen Port. 3 Sl4o Éd Be Compact Camp, Ticket Vt 4 Shouldbe Stutable Fr Ambulatory Patients, Samp } Ing And Sucyoning Can Be Done With0ut Removjt ‹, Q 5 The System Should Havc Kink Rest Stmg Oxygen Tublng , Double Lumen Endo Bronchial Tube Left- Size-28Fr Low Pressurc Trachealand Bronchial Cuffisto Min Ijrse Risk Ofrn Pcosal Damage. Color Coded Bronchial Euh. Bronchialproxiinal Iumen And Bronchialpilotba|1Oon Assj$ T$Jn Locationott Ube And Tip When Vetificatîon1s C Onfirmeübyfiberopticbron0ho59 Pe. X-Ray Opaque Markers At Distal Lip Abo›E Bronclfial Cul And At Tracheal Openangfor Venficationof Tube [ Position. , Double Lumen Kndo Hronchlal Tuhe Left:Size-32Fr How Pressure Tracheal And Bronchialcuffs To M Înimise Nsk Of Mueosaldamage. Color Coded Bronchial Cuft, Bronclaialproximallumen And Bronchialpif Ot Balloonassists In Locaton Oi:Übe And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope X-Ray Opaque Markersat Distal Tip Aboie Bronchialcuff And At Tracheal Openmg For VerificationoftubejOsi Tion. , Doub E 1Uma Euüobronchîat Tube Loft.Size-35Fr Low Pressure Ficheal And Bronchial Cullsto Minima Se Risk Of Mucosal Damage. Color Coded Bronchialcuff, Bronch Tal Proximal Lumen And Bronchial Pmot Balloon Assists In Location I› I Lube And Tip When Verification Is Confirmed By Fiberopticbronchosccpe. K-Ray Opaque Markers At Distal Tip Above Bronchial Cuts And At Tracheal Opening Tor Verification Of Tube |Aos1tion , Double 1 Umen Findobronchial Tube Lefi, Size-37Fr Lowpressure Tracheal And Bronchialcliffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Curlbronchial Prommal Lumen And Bronchialpilotballoon Assistsin Iovation O1robe And Tip When Vent Cation Is Confirmed By Sberopticbronchoscope X-Rap Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Ven£Caiion Of Tube Position , Double I Timen Endobronchial Tube Left-Size-39Fr Low Pressure Nacheal And Bronchial Cliffs To Jrinijnlse Risk Of M Ucosal Damage. Color Cofied Bronchial Cu1t, Bronehj At Proximal 1 Ujcen And Bronchial Pilot Balloon Assists In 1 Ocapon O I Li Ibe And Tip When Verification Is Conf Rmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cutf And At Traclaeal Openinp• For Verificafio A Of Tube } ›Osition. , Double Lumen Endobronchial Tube 1 Ett.Size-41Fr Low Pressure Tracheas And Bronchial Cuffs To Minimise Risk Of Mucosal Fiarna_•E Color Coded Bronchial Culls Bronchialproximallumen And Bronchialpilot Balloon Assists Ie Location O1 Rr+Be And Tip When Ven Ficafion Is Confirmedby Fi Beroptic Bronclaoscope. X-Ray Opaque Markers At Dj Stat Tip Above Bronch Aj Cub Anfi At Tracheasopening For Verificationof Tubepos Itior , Double Lumen Endobroncliihtube Rightslze-35 F R Low Pressure Trackedand Bronch At Cu Fi To Jrjniirlze Nsk O I Mucosaldamage. Col Or Coded Bronchial Cuffbronchial Proximal Lumen And Bronchial Piiot Balloon Assists In Location Of Tube And Tip When Verificationis Confirmedby Fibreoptic Bronchoscope. X-My Opnque Markers At Distal Tip Above Bronchial Cuff Anh At Tracheas Opening For Ver Ification , Double 1 Um En Cndobronchialtube Right Ize-37Fr Low Pressure Tracheal Andbronchial Cutfs To Minimize Risk Of Mucosal Damage Color Coded Bronchial Curl, Bronchialpmiimal 1 Umen And Bronchialpilot Balloon Assists M Location Of Tube And Tip When Verification Is Confirmed By Fibreoptic Bronchoscope. X-Ray Opaque Markers At Distaltip Above Bronchial Cuff And At Tracheal Operjng For Verification Of Tube Position. , Double Lumen Endobronehialtube Rightsize-39Fr Low Pressure Tracheal Anfibronchial Cuffs To Minimize Risk Of Mucosal Damage. Color Codedbronch Dcuff, Bronchialproximal Lumen And Bronchialpilot Balloon Assists In Locwor Of Tube And Tip When Verificatj On Is Confirmedby Fibreo Ptic Broncboscope. X-Rap Oque Markets At D1sia1 Lip Above Brorchjal Cuff Ancl Attraehealopentag For Veiificati On , Sub-Giottic Tube Taplr Guard Evacsizes 6Mm The Tube Should Have An Additional ] Crnen Integrntedinto Tne Wah Of The Tube To Aliorsuctionmpvof Siitngjttic Space Shoulfihave Cuff In Taper Size To Prevent Micro Aspiration Shout D Have Low Volume / Low Pressure Cutf , Sub-Glottic Tu Be Tapfr Guard Evac: Sizes 6 5Mm The Tube Should Have An Additional Lumen Integratedinto The Wall Of The Tube To Allow Suctiomng Of S1Lopic Space. Should Have Cuff In Paper Size To Prevent Micro Aspirate On Should 1Aa›E Low Volume / Low Pressure Cuff. , $Rib-Glottic Tube Taper Gu.Ard E“7Acsizes 7Mm The Tube Should Have An Additional Lumen Integrated Into The Wall Of The Tube To Allow Suchonjng O I Em Iottic Space. Should Have Cutterpaper Size To Prevent Micro Aspiraflon Shouldhave Low Volume / Low Pressure Cuff , Sub-Giottictube Taper Guardevac. Sizes 7.Smm The Tube Should Have An Additional Lumen Inleeratedinto The Wall Of The Tube To Allow Sectioning Of Sulk Tottic Space. Should Have Cuff In Paper Size To Prevent Micro Aspiration 8Hould Have Low Volume / Low Pressure Cufl , Sub-Giottic Tube 4 Aper Guard Evac. Sizes 8Mm The Tube Should Have An Ad Dltional I Umen Integratedinto The Wall Of The Tube To Allow Auctioning Of Sul^J Ottjc Space Shouldhave Cuff In 4 Aper Sjze To Prevent Micro Aspiration Shound Have Low Volume / Low Presswe Cuff , Sub-Glottic Tube ?8Aper Guard Ev.Ac. Sizes 8.5Mm The Tube Should Have An 6Dditiop61 Lumen Inte@Ated Into The Wall Of The Tube To Allow Auctioning Of Tt| G ] Ottic Space Sho Ujd Have Cuff In Taper Size To Prevent Micro Aspiration Shoiild Have Low Volume / Low Pressure Cuff. , Sub—Glottic Tube Taper Guapd Evac: Sizes 9 Mm The Tube Snou1d Have An Additional Lumenintegrated Into The Call Of The Tube To Allow Suctiorfing Of S Ub°Lottjc Space. Should Have Cuf In Taper $We To Prevent Micro Aspiration Should Have Low Volume / Low Pressure Cuff , Lnflation Device Inflation Device In 3Oatm & 20M1 Wi Inclear Polycarbonatebarrel For Easy Visualisation Of Bubbles, I R+Jtnescent Dial, Airless Rotator› Locjr Release Handle For Easy One-Handed Control And Primelok For Easy Preparationusfda Apjaroved , Manifolds In 2, 3, 5Port Ns Th Configurationof Nett-Right Orientation, On-Ot F Handle, Full-Bad R Body, 200 Psi.500 Psi Rating And Wide Port Spacing. Seoul D Ha›E Slear Polycarbonatebody To Provide Durabijity And Visa La Il Ity, Airless Rotator And Large Bore Inner Furriertfrou%Out Inc1ud›Ne Rotatoi.Us¥Da Appicrved , High Pressure Tube High Pressure Tubing In 25Cmpith Braided. Flexible Tubing Of Polyurethane Mtcfi 1200 Psi. Usada Approyed , High Pressure Tube High Pressure Tubing In 51Cmpith Braided. Flexible Tubing Of Polyurethane Mtcfi 1200 Psi. Usada Approyed , High Pressure Tube High Pressure Tubing In 76Cm Pith Braided. Flexible Tubing Of Polyurethane Mtcfi 1200 Psi. Usada Approyed , High Pressure Tube High Pressure Tubing In 122Cmpith Braided. Flexible Tubing Of Polyurethane Mtcfi 1200 Psi. Usada Approyed , High Pressure Tube High Pressure Tubing In 183Cmpith Braided. Flexible Tubing Of Polyurethane Mtcfi 1200 Psi. Usada Approyed , Torque Device Torque Device For014 To , 038 Standard And Hydiophhe Guide Wires With Sq Ccczc- Oad-Release Mechanismusfda Approved , Radial Band Rafiial Hemostatis Band In 24 Cjr . Curvedbacjrer Plat With Large Area & Clear Unobstructed Site Visibility, Convenienttubing Clip With Two Check Valve Options And Dev Ice St I Ckersshould Be Available Math Standard Luer And Specialized Connection Syringeus Idaapproved , Rad Al Band Radial Hemostatis Band In 29 Cm. Cuwedbacker Ptat With Large Area H Clear Unobstructed Site Visibili3’, Convinient Tutting Ct Ipyth Two Check Valve Options And Device Str Akers. Shouldbe A›Yâab1e Crth Standard Luer And Specialized Connection Syinge. K S Fda Approved , Ange Ography Needle Atjqiographyne#D } E In 18G, Length Of 2-9Cmshout D Be Ayajlsble Irecho Enhanced & Em Ooth Finishergonomic Hub Wilh Level Orientation Point, Silicone Coated Stains Est Steel To Reduce Needle Drug And Superior Sharpness To 1‹ C + I Itate Entry Into Tissue And Vessel Wall. Usfd A Approved , Angioeraplayneedle Angiographyneedle In 19G, Length Of2-9Cm. Shouldbe Available In Echo Enhanced& Smooth 1Risbei ¿Onomic Hub With Bevel Orientation Point Silicone Coated S4ajrless Steelto Reduce Needle Dmg And Supeinor Sharpness Toive +Ltate Entry Into Tissue And Vesselwall. Us Fda Approx Ed , Angioeraplayneedle Wgiography Needle In 20G, 1En•Th Of 2-9C R.S1ould Be Available In Echo Enhanced & Smooth Tinish. Ei ;Onomic Hub Vdth Bevelorientation Po+Nt, Siheone Coatedstainless Steel To Reduce Needle Drag And Superior Sharpness Toi Ac Ili Atecnty Into Tissue And Vessel Wal I Fjs£Da Appro›Ed , Angiographyneedle Angiographyneedle In 21G, Length Of 2-9Cmshould Be Available In Echo Enhanced & Smooth Finishe ¿Onomic Hub With Bevel Orientation Poir I, Sjlicore Coated Stainless Steel To Reduce Needle Dme And Superior Sharpness To The Ilitate Entry Into Nssue And Vessel Wall Tjsfda Approved , Angiography Wire Ptfe Guidewire In .035 O38Inregularlegth. Shouldhave 3Mm J-Tip, Straight Tip, Pro-Coati Nfor Smooth Surface With Less Faction, Finger Straight-Able With Precise J-Tip Memory And Packedin Flush Loop With J Stra:I+Tener. Should Have Option Of Fixed Ccre, Movable Core, Heparin Coating, 1.5Mm I-Tip. Us Fda Approved , Angiographywire Long Length Ptfe Guidewire In 035, 038. With Exchangelength Should Have 300 J-Tip, Straight Tip Precoating Forsmooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memoryand Packed In P Rsla Hoop Wi I H .1 Stiaightener. Should Have Option Of Fixed Core, Movable Core, Heparij4 Coating, 1 5Mm J-Tip. Usfd‹ Appro›Ed , Amplatz Wire Ptfe Ainplatz Type Arein .035 And038, Length Of 75Cm, I 45Ein, L80cm. Should Be Available In Init I:I P.E Flexible Tip Length Of 1 Ocm;5Criocro6cm, 7Er» Andj 3 Ommusfda4ppro›Ed.Usrda App‹Ove6 , Hydrophilic Wirehydrophilic Guidewire Of 018, 025, 035, 038 In 80 Cm, 150Cm With Straight. Angled Tipshoul A Co»E In Stiff & Standardconfiguration Niñnol Core Polyurethaneackct Hydrophilic Coated Guide Wires With Rad Opatieacket For Enhanced Wslbil Iy Hydrated Get Coating And True . Itorquenj Sfda Approved , Hydrophilic Wire Long Length Hydrophrilic Guidewe Ot.0 I8.025, 035.038 In 180Cm. 220Cm. 260Cm Length With Straight Angled Tip Should Come In Stiff & Standard Configuration Nitinol Ore Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visiblity Hydrated Gel Coating And True 1:1 Torque Usfda Approved , Hydrophllic Bmided Sheath Hydrophllic Bmidedsheathjntroducer In 4F To 7F, Lergt ] Of 7, 11, 16, 23Cmwith The Option Of.018 021 , .025 Plastic Jacketed And Sprin° Coil Guidevire. Should Have Ultra-Thin Wall And Fiai Vdre Braidlng Technol Ogy To Preldc Support And Low Profile Usfda Approved , Femoral Sheath Wilh Needle Femoral Sheath In 5Fto 8F, Length Of 11-232Cmwith Punched Needie Of 18G And Gidewire Of035, 038 Should Haverotating Suture Ring, Snap-Fit Dilator To Prevent Slipping Duimg Insertion And Holster Packshould Be A Ai Table In Polypropylene Usfda Approved , And Ography Catheter Diagnostic Catheter In 4F - 6F, Length Of 70- I 10Cm& 125Crn , Should Come In Yabous Shapes & Cute Lengthincluding Jl & Jr ( 1.5, 2. 2.5, 3. 3.5, 4, 4.5, 5, 6 Cm ) , Al, Ar, Tig, Mp, Im, Sones, Pigtail ( Straightangle, Radial ) Sloom D Have Flat Wire Braidingh Nylon Material Thin Wall Design For Higher Flow Rates Radio-Opaque Tip Strain Relief And Wingedpolycarbonate Hub Shohj Fi Be Available In Yabous Configurai Ons- Branded, Nomabraided, Short Tip, Bumper Tip, Sideholes As Applicableus Fda , Angiographyradialcatheters Diagnosticrad Ial Catheter Vith Radial Ulhmate Curve In 4-6Flenght Ofl00cm110cm, L2ocm S Laotild Have Four Type Of Radi Ai Ultimate Curves. Shouldhave Flat Care Braldine, Nylon Material, Thin A All Design For Higher Tloorates, Radio-Opaque Tip, Strain Relief And Winged Polycarbonate ] Jijb. Us Fda Approved , One Hop &Triple Loop Mare Snare Kit ( 2-35Mmdj Ameter, 90-Degree Nitinol & Gold-Piated Tungsten Loop ) And Multijoop Snare Kitt2-4 Ohm Diameter, Three Interlaced N Ijcol Loops ) For Foreign Body Retrieval, Should Come With Flexible, Reinforced, Strain Rel E H C+ B To Reduce Buckling And Unique Peel Awayinsertion Tool. Usfdaapproved , Ptca Kit ( 1 ) Three Port Manifoldv Itla J‹Nobs To TumRight” When Open ( 2 ) One Pressure I Ine, ( 3 ) Fluid Connec I I R I Ine, ( 4 ) Contrast Coi!Iaecting Line, ( S } One Three Way Stop Cock ( 6 ) One Y-Connectorloemoststi E Valve Witty Spring Type { U Ush And Release Mechanism, ( 7 ) One Rich Ation Dev Ce Vzth Manometer Upto 30 Atm ( Easy To Operate With 1 Uminescer T D +A1 I8 ) One Luer Lock Controlled Syringe Of 10 Jul Wjtil Finger Grip ( 9 ) Insertionneedle, ( 10 ) Torque Device.Usfda Appro› Ed , Closed Suctiorcatheter For Paediatrics Number And Color- Coded Graduations 1Or Controlled Depth Suctioning.Separate Y Connectors Available‹›R Different Tubes In The Pack.Catheteris Made Up Of Medical Grade Siliconmaterial Sizes Are 5Fr , Closed Saction Catheter For Paediatrics Number And Color- Coded Graduations Fur Cc›Ntrolâ Ed Depth Summoning Separate Y Connectors Availabj E Birr Different Tubes In. Be Pack Catheter Is Mnde Up Of Medical Grade Silicon Material. Sizes Are 6Fr , Closed Suction Catheter For Paediatri Cs Number Andcolor- Coded Gradualions For Controlleddepth Suctioning.Separate Y Connectors Avadab1cliar Different Tubes In The Pack Catheter Is Make Up Of Mcdi Cd Grade 8 J4lcon Materalsizes Arc Qtr. , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Control Led Depth Sectioning Separate Y Connectors Availabl C For Different Mbes In The Pack.Catheter Is Made Up Of Ir Edical Grade S Jjicon Material.Sizes8fr. , Closed Suction Catheter For Paediatries Number Andcolor- Coded Gaduationsfor Control I Ed Depth Suctionipg.Separate Y Connectors Availabl E For Different Tubes In The Pack Catheter Is Made Up Of Medical Grade Siheon Material.Sizes Are1ofr , Closed Suction Catheterfor Paediatrtcs Number Andcolor- Coded Graduationsfor Control Led Depth Suction Ing.Separatey Comiectors Avaijabj E Tier Different Tubes In The Pac1‹. Catheter Is Made Up Of Medical Grade Sil Iconmaterialsizes 12Ir. , Paediatric Endotrachealtube Paediatric Microculf Designed According To The Paediatric Sratomy .Cuffis Mnde Up O1 Polyiir Ethane.31I Ckress Of Cub S 10 Micronsnfj Crocuff Seals At Araverage Cutt Pressure O1 1 Icmh2o Burst Pressure O1 Cuff Is 805Crnh2‹›Auatomicahybased Intubationdepth Marking With Precisi On Bands.Cuff With Pj Ay Mode Function. Sizes Are 3Rrur. , Paediatric Endotrachealtube Paediatric Microcuff Designed Accordingto The Paediatric Anatomycuff Is Made Up Ofpolyurethane. Thickness Of Cuff Is 10 Microns Microcuff Seals At An Avemge Cuff Pressure Of 11 Cmh2o.Bcrstpressure Ofcuff Is805cmh2oanatoiricaly Based Intubation Depth Markingwith Precisionbands Cuff With Play Mode Function Sizes Are 3.5Mm , Paediatric Findotrachealtube Paediatricm Icrocuff Designedaccording To The Paediatrc Anatomy.Catt Is Made Up Of Po1ycirct1ianc, T1 I Ckness Of C Ml Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o Burst Pressure Of Cuff Is 805Cinh2o . Natomically Based Intubationdepth Markme Veth Precisionbands.Cuff With Play Mode Functionsizes Are 5 5Mm , Adult Endotracheal Tube Cuff Is Made Up Of Ployurethane.Thickness Of Cuff Is 10 Microns.Microculf Seals At An Average Cuff Pressurc Of 20 Cmh2o.Burst Pressure O1 Cull Is 800Emh2o. Cuff With Playmode Function Sizes 5.5Mm , Adult Endotracheal Tube Cuff Is Made Up Of Ployurethane.Thickness Of Cuff Is 10 Microns.Microculf Seals At An Average Cuff Pressurc Of 20 Cmh2o.Burst Pressure O1 Cull Is 800Emh2o. Cuff With Playmode Function Sizes10mm , Kimventbecath Non Bronchoscopic Box For Bronchialaspirate Sampling. Can Be Performed In Minutes At Bedside1â I Rectiorialfipalloys Right Or Left Lung Sampling Maintains Prep When Used With Suppl Ied Ventilator Adaptersofi, Cushiore‹I Radiopaquehp F-Or Safe Sampling. Protected Vjt1a Outer Catheter Covering. T Size 13Fr , Kimventbecath Non Broilchoseopic Bal For Bronchial Aspirate Samplingcan Be Performed In Minutes At Bedside.Tâ I Sectional Tjp Allows Right Or Felt Lung Sampling Maintains Peep When Used With Supplied Ventilator Adapter. Sofi, Cusbio»E‹!.Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering Sizes16fr , Disposable Spo2 Sensor It Should Be Base On Originalnellcor Tecbnol Oey Withongmaloximaxtechnology , Catheter Mount Doubt E Swivel Connector.It Should Have Bronchoscopyport . It Sholud Be Approvedby Usfda , Gastrostomy Feed Ing Tube Medical Grade Sjlicone Construchon. Lcw Poodle Desigo. Tapered Distal Lip, S1tcone Internal Retcnl Ir›Iiralf Oon. Distal Tip Recessed At 5M.Lpiozimalanti Reflux Velvc Secur Lok Extention Set Connector Mechanisnradiopacj Ue Stripe, Gamma Sterilized Siz—E I 2, Length ( 0.—Fi5.0 ) , Gastrostojry Feeding Tube Medical Grade Siljcone Constructionlow I*Ro1ije Design.Tapered Distal Tip, S Iljcone Intern.Alretenti‹»Aballoon.Pistal Tip Recessed At 5M Lproximalanti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radioya‹ U.• Stripe.Gamma S Terilizeds Iz—E14 Length ( 0.—85.0 ) , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Ny, Si1icone Internalretent Onballoon Distal Tip Recessed At Sm Lproyjma| Anti Reflcx Valve.8 Ecur Lok Extention Set Connector Mechanism.Radiopac| Ue Stripe, Gamma Sterilizedsize — 16 Lengtht0 8 — 5.0 ) , Gastrostoiry Feeding Tube Medical Grade Silicone Construction Low Profile Design Tapereddial Lp, S11icone Internalretenti ‹›N 1Al1oon.Distal Tip Recessed At 5M.1Proximalanti Reflus Val›E.Secur Lok Extention Set Connector Meehanism, Radiopa9 Ue S Tripe, Gamma Stenlixeds Iz—E18, Lcngth ( 0.S—5.0 ) , Gastrostomy Feeding Tube Medical Grade Sh Icone Construction.Low Profile Design.Tapered Dislal Tip Silicone Internal Retent+Canball Oon Disral ‘Tip Recessed At Srn.Lpro:Simal Anti Reflux Valve Secur Lok Eitention Set Connector Mechanisrn, Radiopacjue S Tripe, Gamma Ster+1Mds Ize — 20 Length ( 0.—85 0 ) , Gastrostomyfeeding Tube Medicagrade Silicone Construction.Low Profi Ie Design.Tapered Distaiup.Silicone Internal Reten1+Onball Oon Distal Top Recessed At 3M Lproxiiral Anti Regux Value Scent Lok Extention 8 Ct Corrnector Meehanism, Radiopac|Ue Stripe, Gamma Sterile.Ed Size — 2‹Tr Len H ( 0.8—5.0 ) , Percutaneousendos Copic Gastrostomy ( Peg ) Medical Grade Silicone Constructioja Externalretention Ringuniversa| And Bogus Feedmg Port Co;-Irirctors, Medjypjj Port Col Lapsible Internal Retention Bumper.Radiopaque Stripg And Pumper. Lubing C ] Amp Ei 0Steri Ljzed.S Ize-S I 4Fr , Percutaneousendoscopic Gasprostomy ( Peg ) Medical Grade Silicona Constructionexternal Retentionring .Universaladbolus Feedmg Port Colncctors, Medicatjon , °Ort.Co1lapsibie Internal Retention Bumper. Radiopaque Stripo And Bumper Tubing Clamp Eto Sten1 J Zed Sizes —20Fr , Percutanyou S Endos Copic Gastros Tomy ( Pec ) Medical Grade Sin Icone Construí Tion.Externalretentionr Mguniversal And Bolu$ F9edjjjq Port Cole Necir3, ] Vt#Djqatj Jj Port.Coi1apsib1c Internal Retentiondurnper.Radio } Aaque Stripe And Buinpcr.Tubing Clamp Eso Steril Ized Size—S24fr , Silk Protein Based Stent E Surgical Pufeajr Dressing Non Adhesive I3j Oulodlfied, Silk Protein Based, Sterile, So11. Conformable, Absorbent, Douhle Layered Polvurethene Loan Dressingcomprised Of Sill Protein 8% And Asiaiicoslde Elt 0 6%, Ivjth Super Fluid Handling Capacity, Decreases The Risk ‹›! Iuacerauon.Ster1ization-Camera Sterlized , Silk Protein & Antimicrobialranosilver Based Sterile Surgical Pu Foam Eressing Non Adhesivebiomodified, Silk Protein & Silver Impregnated Soft, Corformable, Absorbent, Double Laered Polyurethene Foamdressingcoinprised Ofsilk Protein 8%, Asiaticoside Nlt 0 6% Abad 8 Ijver 1.2%With Super 11 Mí Laandling Capacity, Decreases Dye Risk Of Inaceratioiysterlizotior-Gamma Stern Ized , 4 Ilk Protem & Antimicrobial Si1›Er Based Sterile Surgical Mesh Wound Dressing Bjomodified. Bid Ainjcaled Silk Protein And Sit Ver Wound Dressing With Mesh Pores To Facilitatethe Eas ‹1I Ainage Of Exudates, Compri Sed Of Acti›Atedsilk Matrix 46?O And Asiaticoside Nlt 0 6% And, Steri Ination-Gamma Sterlized 8 +1› Er I2%. Non- Adhesit• Esquare / Rectangular In Shapc, Steri Jzatlon-Gamma Sterlized , Silk Protein & Antimicrobial Nanosllver Based Sterile Surgicalwounddtess Ing Sheet Bio Rofilfiefi, Bilaminatedsilk Protein & Sil›Er Based Surgical Wounfidressing Comprised Of Aetjvatet!Silk Matrix 46% And .Asiatieoside 0.6% And Silver :1 .2%. Non- Adhesjsquare / Rectangular In Shape, Sterlizatior-Gairm A Sterlized , Sink Protein Derived Sterile Surge Cal Meshefi Wounddres Sing Bio Modified. Bilaminated Silk Protein V Ound Dressing With Mesh Pores To Facilitatethe Easy Drainage Of Exudates, Comprisedof Activated Silk Matrix 46% And .A S I.Itjcoside Nl30 6% Non- Adhesii E Dressing, Square / Rectangular In Shape, Sterl Ization-Gamma Sterhzed , Silk Protein Based Steriie Surgical Wound Dressing Sheet Biomodified, Bilaminated Silk Protein Wound Di Essing Compnscd Of Activated Shk Matrix 46% And Asiaticoside Nlt 0 6%. Non- Adhesive Dressing, Square / Rectangularshape.Ster1ization- , Silk Protein Based Aniiirlerobial Woirndhealing Oinmientloaded With Asiatj Cost De And Silver Bio Modified Sj Lk Protein And Silver Based Wound Healing Ointment Comprised Of Sillpowder 8% , As U 1 + Coside Nlt 0 6% And S Ilver: I.2%, Sterl Izati On-Gammasterilzed , Silk Protein And Nanosilver Based Microbicidalsten ] E Surgical Wound Dressing Sprinkling Powder Boi Thg1oinod¡Fied Sin Protein And S Iller Based Micro Bicidal Sprinkl Irgpo Der, Cojrprised Of Shk Powder 8%, As Iaticosidenif 0.6% And Silver .1 2% Conforms To Any Wound Shape And Size, Easy To Apply.Steriization-Gamma Sterlized , Silk Proteinbased Sterile Surgical Sound Dressing $Prinkl Ing Powder Bottle Biomodifiedsilk Protein Based Noundhealing Sprinkling Pow‹1Er, Co Rpri Sed Of Silk Powder 8% Andas I Atieoside Nlt 0.6% Conforms To Anv Wound Shape And S Ize, Easy To Apply.Sterlization-Gamma Stern Ized , Centella Asiaiica Extractbased Skinroisijmc Or And Antiscar Gel Centella Asiatica Extract Based Skin Moisturjzation And Aritiscar Gel, Comprisedof Centella Asiatica Extrac L Glycerol And V Itamine., Sterlization-Gamma Sterlized , Silkprotein Basedsterñe Surgicalparticle Wounddressinpbiomod Ified, Bioabsorbable Silk Protein Anal Collagen Cortairing Qarticle Wovnddressing, Comqrtsedof Silk Qowder A% , Aslatlcosjde 0.6% Arts Co1 ] Agen, Baving Natul Allnoistufizing Factor ( Nmt ) , Suitable For Cavity Vound Andarry Kind Of Slow And Non- Healing Wound, Sterlization-Ganijala Sterlized , Silk Protein And Antimacrobialnanosilver Based Sterile Surgical Phicle V Ound Dressing 5Ml Biojr Difiod, Bioabsorbable Silk Protein, Collagen And Silver Containing Broadspectrumantjmi Crobj Atparticle Wounddressing , Comprised Of Silk Powder 8%, Asiaticosifie 0.6% .Having Natural Mo Stunzmg Factor ( Nsf ) . Sui Table For Deep, Tu+One King Cavity Wo Und Or Any Kind Of St Ow And Non- Healing Wound, Sterlization-Gamma Sterlized , Silk Protein And Antimicrobial Nanosilverbased Sterile Surgical Parncle Wound Dressing1omlbiomodified, Oabsorbable Siik Protein, Collagen And Siler Containing Broadspectruin Antimicrobialparticlewoundvjressing , Comprised Of Silk Powder 8%, Asiaticosidc 0.6% , Having Natural Moisturizing Factor ( Nmf ) , Suitable For Deep, Tunnel Ing Cavity Wound Or Any Kind Of Slow And Non- Head Ing Wounhslerlizalion-Gamma Sterlized , Silk Protein Based Non-Woven Backed With Pad & Seltadbesi Ve Border, Water-Repellent Sterile Surg*Calfi Ressing 10*20Cm, Silk Proten And Nanocrystalline Si Leer Based Highly Conformable Sterile Antlmicrobialdressing With Ad1ctive Backing And Absorbent Layer , Sterlizntion-Gamma Sterlized , Sillr Protein Based Non-Woven Backed With Pad & Sell Adhesive Border, Water-Repellent Sterile Srirg Ical Dressing I0*2Ñcm, 8Ilk Protein And Nanocrystal Iine Sit Ver Based Highlyconformable Steel C Antiiricrobial Dressing With Adhesivebacking And Absorbent Laver , Sterhzation-Gamma Ster1ized , Silk Protein Based Non-Wovenbacked V Ith Pad & Self Adhesive Border, Water-Repellent Sterile Surgcaldressmg15*15Cm Sillr Protein And Nanocrysiajl Ine Silver Based Highly Confonrable Sterile Antimicrobialdressjrjg Wjth Ad!Aesive Backing And Absorbent Layer , Steriization-Gamma Stcrlized , Slib Protein And Pu Foam Pad With Sell Adhesive Border, Naier-Proof Dressing For Post-Operative Scar Or Any Scar Managemen 10*20Cm , Sick Protein Based Highlyconformable Sterile Pu Foam With Antiscarring Properties And Ad*Es Ve Backin, Sterlization-Garnera Sterlized , Silk Piotem Arid Pu Foam Pad With Set I Adhesive Border, Water-Proof Dressing For Post-Operalve Scar ‹›Rmy Scar Managemen 10*2Scm Siik Protein Based Highly Contficnable Sterile Pu Foam »Nth Antiscamng Properties And Ad Laesive Backimsterlizauon-Gamma Sterlized , Silkprotein And Pu Foam Pad With Self Adhesive Border, Water-Proof Dressing For Post-Operative Scar Or Any Scar Management 10*20Cm Silkprotein Based Highly Confonnable Sterile Pu Foam With Antiscarring Properties Andnd Hesive Backm, Stcrlization-Gamma Sterlized , Silk Proteinnanosilver And Asiancosid C Based Pu Film Backed With Pad & Self Adhesive Border, Ther-Proof Sterile Surgical Dressing 9*21.Gemsilk Protein, Ranocrystalline Silver & Asjaticoside Based Highly Corformable Sterile Anomjcrobialsurgical And Scar Free Woiuld Healing Dress*Ng Ntb Adhesive Backing And Absorbent Jayer, Sterlization-Gamma Stcrlized , Silk Protein, Nariosalver And Asiaticosifie Based Pu Film Backed With Pad & Self Adhesive Border, Water-Proofsterile Surgical Dressing 1025Cmsixprotein, Nenocrystalllne Silver & Asiaticoside Based Highly Conformable Sterile Antimicrobial Surgical And Scar Free Wound Healing Dressing With Adhesve Backing Anfi Absorbent Iayer, Steriization-Gamma S Tcrlazed , Silk Protein And Antimicrobialnanosilver Impregnatednon-Afierent Leno Gauze Sterñe Surgical Wound Dressing 10*10Cm Silk Protein & Nanocrystailine Silver Based Sterile Non-Adherent Antimicrobial Gauze Dressing Sterlization Ganna Sterlized , Silkproteinand Antimicrobial Nanosilver Impregnated Non Adherent Leno Gauze Sterile Surgical Wound Dressingh 10*25Cm Silk Protenin & Nanocrystalline Silver Based Steril Non Adherent Amtimicrobial Gauze Dreeingsterlization Gamma Sterlized , Silk Protein Impregnatednon-Adherent Meno Gauze Stenle Primary Surgical Wounddressing 10*10Em S11 K Protein Based Sterile. Nojj-Adherent. Antimicrobial Gauze Dressing , Sterlizallon-Gamma Ster ] Ized , Silk Protein Impregnatednon-Adherent Meno Gauze Stenle Primary Surgical Wounddressing 10*25Em Silk Protein Based Sterile. Non-Adherent. Antimicrobial Gauze Dressing , Sterlizallon-Gamma Ster ] Ized , Pyaain-Urea & Silk Proteinbased Wound Debriding Ointment And Cream 25Gin Papain-Ureabased Fiebriding Ointment Sud Cream For Rejnoval Of Necrotic Óssue And Slough In Infectcd Uounds. Containing Papainl . •52 1700 Units Arid Urea Ip . 100Mg , Papaln-Urea & Sill Protein Based Wound Debriding Omtment And Cream50gm Papajc-Àreabased Debridj Ag Ointment And Cream For Rejnoval Of Recrotic Tissuc And Slough In Infected «Ounds, Contan Ng Papain Ip . >521700 Units And Urea Ipi 00Mg , Silk Protein, Asiaticosidc Anò Povidone Iodine Based Broad Spectruirtopical Aritiseptic And Antjjnicro B Ial Wound Healing Ointment 25Gmbroad Speeírum Antiseptic And Antimicrob Tal Topreal Of Ntment Contajn Ing Povidone Ionineusp5% W / W, Silkproleln, Center Ja Asiatic0 For Prevention Of Skln And Wound Infections , Silk Protein, Asiaticoside And Povidone Jodine Òased Broad Spectrum 1Opu.Al Aiatisept; C And Antimicrotom Wound Heajing Omtment50cin Broad Spectrumantisept C And Antimicrobial Topicsl Oindnent Containing Povidonc Ioú J Ue Usp5% W / W, Sili Proteincentella Asiarea For Preventionof Skin And Wound Infeetions. , Anti Mlcrobial G1oves Size 6, 6.5, 7, 7.5, 8 , Anterior Chamber Iol Pmma Material, Single Piecekelrnanmultiflex Design 5-6 Mm Optio Size With 12-13 Mm Overal I Sizeconvex Power Range * 12 To +24Should Be Iso Or Ce Certificdmarufacrurer Shoul D Be Asked To Sample For Approval , Capssar Tension Ring Standard Capsular Tendienringpmmmaterial With One Eyelet Each At Each End10 Mm To ! 2 Mm Overal I Diameter Sterile Shoulfibe Iso / Ce Certified Mfg. , Iris Hooksdetractors Set Of Five Disposable Steri Le Iris Hooks With So Ú Sis Icon Stopper Stcrile Peek Should Be Made Pmma Ii O / Ce Certified !Vifg. , Sillcone Rod For Ptosis Repair I Nplantable Fiexible Sis Icon Rod Attached To Majjeable Sharp Needles With A Siiicon Sleeve. Leed1et.Engihi 0-70Mm Djameter 920 Glength Of Silicone Rod 40Crn, Lengih Of Silicon Sleeve 0 7 Mín. , Reusable Anaestbet A Face Maskof Silicone A Utocalvablempere Transparent U8 Fda Approved And Size Should Be Mentioned On Mask Isze -0 , Reusable Anaesthetia Face Mask Of Siiicone Autocalvable & Pure Transparent.Us Fda Approved And Size Shouldbe Jrentionefion Mask Size-1 , Reusab Íe A Naesthetia Face Mask Of Sllicone / Yutoca1vable & Pure 1 Ransparert.Us Fda Approved Ajad Size Shouldbe Mentioned On Mask Size-2 , Rcusable Anaesthetia Facemask Of Sdico Ne Autocalvable & Pure Transparent.Us Fla Approved And Size Shouldbe Inentioned On Mask Size-3 , Reusablea Aacsthetia £Ace Mask Olsjj1cone Autoeaji Able & Pure *Ransparent Us Fda Approved And Size Should Be Mentioned On Masksize-4 , Reusable Maesthctia Face Rnas1‹ Of Siiicore Autocajvablc & Pure Transparent.Us I Da Approved And Size Should Be Mentionedon Mask. Size-5 , Flow Regulatorextension Set Flow Rate 2Ml To 350M1 Per Hour , Steriledisposable Hypodermicneedle No18*1.1 / 2 , Sterile Disposable Hypodermicneedleno. 21*1.1 / 2 , Sterile Disposable Hypodermic Needleno. 23*1.1 / 2 , Neonatal Sin%E Heatedwire Breathing Systemwith Autofillhumidi Fican On Chamber In Steriie Pac Ku D Us Fda Approved. Shouldbe Compatibleevery Humidifier , Paed. Single Heated Wire Breathing Systemwlh Autofill Humidification Chamber In Sterile Pack An Clus Fda Approved. Should Be Compatible Everv Humidifier. , Adult Sulgle Heated Wire Breathing System With Autofill Hurn Idificationchamberin S Terile Pack Andus Fda Approved. Should Be Compatibleeven Humidifier , Neonatal High Flow Nasal Cannula Having 8 Litre Flow Should Have Soft Tip . , Pur-Xro Catheter 20 Em, 28G Ifr Pice Line With Stylet, Splittmg Needle With Securing Wings Vit+A 8 Cm Extension Tubing ( Flow Rate 1Ml / Min ) , Per-Xro Catheter 30 Cm, 24Gj2fr Picc Line With Split Cannula And 10Cm Extension Tubing Over Erms Eter ( Flow Rate , Dead Bodybas7x3 Fi Size Lead Proofmaterialpp Closed On All Other Sides And Zip Ped On Front Or On› Sodes , Introducer Sheathwtth Punctureneedlefor Adults Us Fda Approved10-11 Cm Long Hack Must Mclude 18 G, 6-7.5 Cm Long Puncture Needle.0.035 Or 0 038 Mch Guide Wire Oompat+Blevith Haemoslatic Valve Oprevent Back Leak And Air Aspiration-Integral Side Port O I Th Allached 3-My Stopcock With Suture Eye For Secunog Sheathkbresistant With Dilator-Sub Lock Mechanism To Prevent Its Back-Out During Insertionwith Smooth And Resistance Free Insertion Size 4Fr Standard Length , Introducer Sheathwtth Punctureneedlefor Adults Us Pda Approved10- I Icm Long Pack Must Include 18 G, 6-7.5 Cm Long Puncture Needs E.0.035 Or 0.038 Inch Guide Wire Compatiblewith Haemostatic Valve To Prevent Back Leakand Air Aspiration Integral Side Port Itill Attached 3-Way Stopcock With Suture Eye For Securing Sheathkink Resistant With Dilator-Hub Lock Mechanismto Prevent Its Back-Out During Insertion With Smooth Aaad Resistance Free Insertion Size 9Fr Standard Length , Introducer Sheathforadults ( Size 10 Fr.. ) ( Standard Length ) U8 Idaapproved Us Gfsce / Dgci Approved 10-11 Cm Long0.035 Or 0 038 Inch Guide Wire Compatible With Haemostatic Valve To Prevent Back Leak And Air Aspiration Integral Side Port With Attached 3 Way Stopcock With With Eye For Securing Sheath Kink Resistant With Dilator Hub Lock Mechanism To Prevent Its Back Out During Inscrtion With Smooth And Resistance Fuee Insertion Us Fda+Ce / Dgc Approved Ci Approved Size-10Fr , Intoducer She.Rth For Adu Lts ( Size 11 Mr ) ( Standard Length ) Us Fdaapproved Us Fda+ Ce / Dgci Approved10-11 Cm Long0.035 Or 0.38 Inch Guide Wire Con Pat Bie Uith Haemo
Contract Date: Sep 18, 2023 Contract Value : 59.00 Lakh
Government Departments No of Bidders 7
Contract Date: Dec 07, 2022 Contract Value : 42.86 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
Contract Date: Jul 21, 2023 Contract Value : 50.81 Crore
Government Departments No of Bidders 5
Dadra And Nagar Haveli View Result →
25.
Defence #1791875 AOC
Repairs / Maintenance Of Miscellaneous E / M Equipment And Cooling Appliances And Allied Works At Pedong, Algarah, Dalapchand, Ap Algarah, Rhenock, Rongli And Teesta Tcp Under Ge 867 Ews- 1 Excavating Over Areas, N Exc 1.5 M Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 2 Removing Excavated Material Exc. 250 M But Not Exc. 500M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point All As Directed By Eng In Charge 3 M&L For Moorum / Red Bajri Filling In Floors Or Pavings, Laid In Layers N.Exc 15Cm Thick, Spread, Levelled And Rammed Including Watering Complete All As Specified And Directed. 4 M&L For 25Mm Thick Cement Concrete Type B0 1:2:4 ( Using 12.5Mm Graded Aggregate ) As In Flooring As A Leveling Coarse Cement Concrete Surface Complete All As Specified And Directed. 5 M & L 25Mm Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Complete All As Specified And Directed. 6 M&L For Machine Pressed Precast Concrete Interlocking Paver Block With Grey Cement And Pigment Any Shape And Size As Approved By Eng In Charge Confirming To Is 15658-2006 Of 80Mm Thickness M-40 Grade Complete All As Specified And Directed. 7 Material & Labour For Machine Pressed Precast Concrete Interlocking Paver Block Of Approved Shape And Size Of 60 Mm Thickness, With Minimum Compressive Strength Of 35 N / Sqmm ( M-35 Grade ) , Without Correction Factor For Chamfering, Made In Rubber Moulds With 0.50 Mm Thick Scratch Proof Lacquer Coating, And Top Surface With White Cement And Pigmentcomplete 8 S&F In Repairs 500 Ltr Rotational Moulded Polyethylene Water Storage Tanks ( Cylindrical Vertical With Closed Top ) Hoisted Double Layer And Fixed In Position All As Specified In Ssr Part I, Including All Fitting Such As Connection Pieces With Gi Tank Nipple For Inlet, Outlet, Washout And Overflow Etc And Including 25 Mm Size Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe Also Removed For Old Tank Complete All As Specified And Directed. 9 Supply And Fix 1000 Litres Capacity, Rotational Moulded, Polythene Water Storage Tank ( Cylindrical Vertical With Closed Top ) Histed And Fixed On Roof In Position, Including All Fitting Such As Connection Pieces With 25Mm Dia Gi Tank Nipple Of For Inlet, Outlet, Washout And Overflow Etc Complete All As Specified And Directed. 10 S&F 25Mm Ball Brass Valves, High Pressure, With Polythene Folat And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed. 11 S&F 25Mm Dia Stop Valves, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed Complete All As Specified And Directed. 12 M&L For Removal Of Existing Roof Treatment Consisting Ofscreed Bed, Tar Felts Etc, Andremoval Of Debris Outside Md Land Complete All As Specified And Directed. 13 M & L For Rendering10 Mm Thick Onconcrete Surface Whilst The Concrete Is Green, In Cement Mortar ( 1:4 ) Finishing The Surface Even And Smoothwithout Using Extra Cement, Including Mixing Only Liquid Water Proofing Compound As Per Manufacturer Instruction Complete All As Specified And Directed.Note:- Wpc Will Be Measured & Paid Separately 14 M & L For Water Proofing Treatment By Applying One Coat Of Oil Base Bituminous Primer @ 0.3 Kg / Sqm With Brush / Roller, Laying Of 3 Mm Thick App Based Polymer Modified Membrane Reinforced Non-Woven Polyester, Weight Not Less Than 3.50 Kg / Sqm And Sealing All The Over Laps 100 Mm In Length Side And 100 Mm In Width Side Of Membranes Laid With Torch Application Complete All As Specified And Directed. 15 M & L For Plain Cement Concrete 1:2:4 Type B0 Using 12.5 Mm Graded Stone Aggregate, ( Avg 50Mm Thickness ) In Roof For Padding To Achieve The 1:40 Slope Complete All As Specified And Directed. 16 M & L For 15 Mm Thick Rendering In Cement Mortar 1:6 On Brick Work / Concrete Surfaces / Pcc Block / Stone Masonry Wall Surface, Ifinished The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 17 M&L For 5 Mm Thick Rendering In Cement Mortar 1:3 On On Ceiling, Ifinished The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 18 Supply Only Liquid Water Proofing Compound 19 Demolition Of Un-Reinforced Cement Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For And Removing The Same To Out Side Mod Land. 20 Disconnecting Existing Tanks Exc 250 Ltr And N Exc 500 Ltr , Setting Aside ( Or Lowering If Required ) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position After Cleaning Repairing, Etc. As Directed. 21 M&L For Complete Removal Of Existing Treatment From Wall Including Brooming Down Or Steel Wire Brushing, Scraping Down Complete And Applying Two Coat Of Distemper Oil Emulsion A Coat Ofchalk Whitening Compatible Primer Complete All As Specified And Directed. 22 M&L For Preparation Of New Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash Complete All As Specified And Directed. 23 M & L For Preparation Of Old Decorated Surfaces Of Ceiling ( Plastered Or Unplastered ) By Brooming Down, Scrapping Down Smoke Soot, Moss And Efflorescent Salts And Trading Oil And Greasy Spots Etc And Applying Two Coat Of White Wash On Ceiling All As Specified And Directed. 24 M&L For Complete Removal Of Existing Treatment From Wall Including Brooming Down Or Steel Wire Brushing, Scraping Down Complete And Applying Two Coat Ofcement Base Paint Over A Coat Of Primer Complete All As Specified 25 M & L For Cutting Holes In Brick Wall Built In Cement Mortar Or Stone Wall Built In Lime Mortar Exc Half Brick And N. Exc One Brick Thick For Inserting Holdfasts And Making Good Dismantling Portion In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Complete All As Specified 26 S & F Rolled Mild Steel Framed Work As In Doors Or Gates Of Angle Or Other Section Confirming To Fe 410-W, With Gusset Plates, Rails Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering And Hanging And Fixing Complete. 27 S & Fmild Steel Framed Work As In Grills Gratings, Framed Guard Bars, Ladders Etc. With Ends Of Baars Shouldered And / Or Riveted Or Forged Into Spikes And Similar Workcomplete. 28 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing And Rubbish Off The Premises Complete All As Specified And Directed By Engr-In-Charge. 29 M&L For Non-Skid Joint Free Coloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tileexceeding 0.06 Sqm But Not Exceeding 0.11 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Coloured Cement To Match Over And Including 15 Mm Thick Screed Bed Or Bedding Layer Of Mortar In Cm 1:6For Laying Floor Finishes Complete All As Specified And Directed. 30 M&L For Non-Skid Joint Free Coloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tileexceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Coloured Cement To Match Over And Including 15 Mm Thick Screed Bed Or Bedding Layer Of Mortar In Cm 1:6For Laying Floor Finishes Complete All As Specified And Directed. 31 M&L For Joint Free ( Edge Cut ) Coloured Glazed Ceramic Tiles 7 Mm To 8 Mm Thick ( Square / Rectangular ) Polished Of Size 350 X 250 X 7 Mm / 450 X 350 X 7Mm As In Skirting / Dado Etc Laid Over And Including 10 Mm Thick Backing Coat In Cement Mortar 1:4, Set And Jointed In Neat Cement Slurry And Pointed With Coloured Cement To Match The Tiles Complete All As Specified And Directed. 32 M&L For Light Shade Colour Vitrified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles N.Exc 0.36 Sqm In Floors Etc Laid Over And Including 15 Mm Thick Screed Bed Or Bedding Layer In Cm 1:6, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed. 33 M&L For Light Shade Colour Vitrified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished, Area Of Each Tiles N.Exc 0.36 Sqm In Floors Etc Laid Over And Including 10 Mm Thick Bedding Layer In Cm 1:4, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed. 34 Taking Down Steel Water Tubing And Connection 15Mm Dia Bore And Removal From Site. 35 Supply And Laying Of Gi 15 Mm Tubes, Medium Grade, Galvanised, With All Fitting On Wallsin Any Type Of Masnory Or Layingin Floors Complete All As Specified. 36 All As Per Item No 35 Above But Refixing Of Old Pipes Of 15 Mm Dia 37 Taking Down Steel Water Tubing And Connection 20Mm Dia Bore And Removal From Site. 38 Supply And Fix 20 Mm Bore Galvanised Steel Water Tubing, Medium Grade Including Necessary Fittingssuch As Gi Bends, Tee, Union Etc Fixed On Wall / Floor Complete And Connecting To Water Supply Pipe Line Complete All As Specified And Directed. 39 All As Per Item No 38 Above But Refixing Of Old Pipes Of 20 Mm Dia 40 Taking Down Steel Water Tubing And Connection 25Mm Dia Bore And Removal From Site. 41 Supply And Laying Of Gi Tubes 25Mm Bore, Medium Grade, Galvanised, With All Fitting; Laid In Trenches / Fittings On Walls Concealed Type In Any Type Of Masnory Or Laying In Floors Complete All As Specified And Directed. 42 Dismantling Of Ac Ceiling Board In Wall Andceiling ( Fibre, Pulp, Insulation Etc ) Or Insulation Boards / Slabs / Blankets Any Thickness Including Cover Fillets Etc All As Directed And Specified 43 S&F False Ceiling Of Non Asbestos Fibre Cement Building Boards, Manufactured From Homogeneous Mixture Of Cement, Quartz And Cellulose And Cured With High Pressure Steam Using Auto Claving Process Confirming To Is-14862, Of Size 600 Mm X 600 Mm X 4 Mm Thick Fixed Over And Includinganodised Aluminium Powder Coated ( Minimum Thickness Of Powder Coating 50 Micron ) Snap Grid Frame Workof T Section ( Main & Cross Member ) Of Size 25 Mm X 25 Mm X 1.5 Mm Thick In Square Pattern Of Grid Size 600Mm X 600Mm . The Aluminium Fram Work Will Supported On Side Wall With The Used Of Aluminium L Section Of Size 25 Mm X 25 Mm X 1.5 Angles Etc. Snap Grid Shall Be Supported With Hangers Of 4 Mm Dia. Galvanised Iron Wire Adjusting Level Fixed To Roof Slabs / Truss Etc By Means Of Ceiling Cleats Made Out Of Galvanised Iron Flat Of Size 40 X 3 Mm Size 60 Mm Long And Expansion Hold Fasteners 12.5 Mm Dia 40 Mm Long Complete All As Specified And Directed. 44 S&F 0.50 Mm Thick Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall Or Roof, Fixed With Self Tapping Screws As Specified And Directed. 45 S&F Joist, Channel, Angles Or Teesection, Confirming To Gde Fe 410-W Fixed Independently Without Connecting Plates Etc ( Cut To Ordinary Length ) Complete All As Specified And Directed. 46 Demolition Of Brick Work / Stone Work / Pcc Block Masonry Built In Cement Mortar Complete All As Specified And Directed. 47 M&L For Providing Precast Cement Concrete ( 1:5:8 ) ( Using 20Mm Graded Stone Aggregate ) Solid Building Blocks Exc 10 Cm In Width ( With Plain Or Inter Locking Joints As Directed ) Setting In Cm 1:6 Complete In Wall, Pillars And Similar Works Complete All As Specified And Directed. 48 Dismantling Ofstone Slabs And Granite Laid Dry Or Laid Dry And Pointed Of Any Description Or Thickness In Floors, All As Specified And Directed. 49 M & L For Preparation Of Old Plastered / Unplasteredsurfaces Ofwalls Including Cornices, Pilasters, Etc And Applying One Coat Of White Wash On Ceilings Complete All As Specified And Directed. 50 M & L For Preparation Of New Plastered Surfaces Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Chalk Whiting ( Putty ) Complete All As Specified And Directed. 51 M & L For Preparation Of Old Painted Wooden Surface Of Any Description Not Otherwise Described Over 10Cm Width Or Grith And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 52 Taking Down Cement Or Cement Lime Plaster, Any Description On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Including Raking Out Jouints, Hacking For Key, Scrubbing Down With Water Etc. Complete All As Specified And Directed. 53 M & L For Rendering 10 Mm Thick In Cement Mortar 1:6 Over Pcc Block Masonry Wall Surface, Finished The Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 54 Supply And Fix In Repairs 10 Litre Capacity Pvc Syphonic Action Type Flushing Cistern Low Level With Inlet Ball Valve, Float, Handle 18322 Flush Pipe Of Polyethylene Of Low Or High Density Or Pvc. 32 Mm Dia, For Low Level Cistern, Fixed In Position And Connecting Complete All As Specified And Directed. 55 S&F In Repair 450 Mm Long Pvc Connections 15Mm Size With Ptmt Nuts At Both Ends Complete All As Specified And Directed. 56 S&F In Repair 15 Mm Size Bib Tapscast Copper Alloy, Chromium Plated, Fancy Type With Capstan Head, Screwed Down, Screwed For Iron Pipes Complete All As Specified And Directed. 57 S&F In Repair 15 Mm Size Stop / Angular Cock, Cast Copper Alloy, Chromium Plated, Fancy Type With Capstan Head, With Long Shank And Cup ( Concealed Type ) Screwed Down, Screwed Both End For Iron Pipes Complete All As Specified And Directed. 58 S&F In Repair 15Mm Pillar Taps Cast Copper Alloy, Chromium Plated, Screwed Down High Pressure With With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe Complete All As Specified And Directed. 59 S&F In Repair Stainless Steel Grating Of Size 150Mm X 150Mm Fixed With Cement Complete All As Specified And Directed. 60 S & F In Repairs For 600X450x5mm Thick Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed. 61 S&F In Repairs 25 Mm Drapery Rod Stainless Steel Complete All As Specified And Directed. 62 S&F In Repairs Drapery Rod Brackets Both Sides Complete All As Specified And Directed. 63 S&F Aluminium Anodised Frame ( For Doors ) Of Size 101.60Mm X 44.45Mm Made Out Of 1.60Mm Thick Aluminium Section, Powder Coated, Fixed To Floor Wall With Plugs And Screws Complete All As Specified And Directed. 64 S&F Anodised Aluminium Glazed Door Shutters Including Mortice Lock 6 Levers Aluminium Body Hydraulic Door Closer As Approved, Door Handle, Tower Bolt, Hinges All Made Of Aluminium Section, Powder Coated ( With Minimum Powder Coating Not Less Than 50 Micron ) Of Adequate Number And Size 52.55 X 44.55 X 44.45Mm And Bottom Rail Of Size 114.3Mm X 44.45 ( Window ) And Jointing Cleats With 12Mm Thick Pvc Hollow Profile Panelling In Addition To Other Fitting As Directed At Site Including Supply And Fix 5Mm Thick Tinted Glass With Necessary Rubber Gasket / Beading, All Aluminium Members Shall Be Made Out Of 1.6Mm Thick Aluminium Sheet / Section ) Notes:- ( I ) Centre Moving Door Shutter With Floor Bearing Hinges / Sliding Door Hinges Door Set Complete All As Specified And Directed. ( Ii ) Pvc Panelling Of Shade As Approved By Engr-In-Charge Shall Be Inclusive Of The Quoted Cost. 65 Supply And Fix In Repair White Vitreous China Wash Hand Basin ( Flat Back ) Of Size 580 X 450 Mm Fixed On And Including New Brackets Complete Including 15 Mm Size Pillar Tap, Cast Copper Alloy, Chromium Plated With Capstan Head, Screwed Down High Pressure, Screwed Shank And Fly Nuts, Screwed For Iron Pipe, 32 Mm Size Brass Chromium Plated Waste Coupling, 750 Mm Long Pvc Waste Pipe, Pvc Connection Pipe, 15 Mm Size And 450 Mm Long With Ptmt Nuts And Washer At Both End Etc Complete All As Specified And Directed. 66 M & L Forexcavating Hard / Dense Soil In Trenchs, N Exc 1.5M Wide And N Exc 1.5M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10Sqm On Plan And N Exc 1.5M In Depth And Getting Out Complete All As Specified And Directed. 67 M & L For ( 1:4:8 ) ( 40Mm Graded Aggregate ) Cement Concrete In Foundations, Filling And Mass-Concrete Complete All As Specified And Directed. 68 M & L For Precast Cement Concrete Block Masonry With Solid Blocks, Exc. 10 Cm In Width And Setting In Mortar 1:6 Type C1 ( 1:5:8 ) 20Mm Graded Aggreagate Complete All As Specified And Directed. 69 M & L Providing Precast Cement Concrete Type B1, 1:2:4 ( Using 20Mm Graded Stone Aggregate ) And Set In Cm 1:6 In Window Or Door Cills, Lintels, Bressumers, Steps, Quoin Blocks ( For Use With Masonry ) , String Courses, Copings. Kneelers, Apex Stones, Pier Caps, Columns, Posts, Boundary Pillars, Bed Plates, Pintle Blocks, Anchorage Blocks, Bonders ( For Stone Wallin ) . Corbels, Brackets, Etc. ( Of Any Section Indicated ) , With Plain Fair Faces, Including Chamfers, Weatherings, Throating Etc. And Setting In Mortar Complete With Joints To Match Complete All As Specified And Directed. 70 M & L For Reinforced Cement Concrete ( Nominal Mix ) Type B1 1:2:4 ( Using 20Mm Graded Stone Aggregate ) As In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And Directed. 71 M & L For Providing Cement Concrete In Roof Kerbs Of Mud Stops, Rounded Or Chamfered On Edges Type B0 1:2:4 ( 12.5Mm Graded Stone Aggregate ) Complete All As Specified And Directed. 72 M & L For Rendering 15 Mm Thick In Cm 1:6 Using On Fair Faces Of Brick Work Or Concrete Surfaces And Finish The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 73 M & L For Rendering 15 Mm Thick In Cm 1:4 Using On Fair Faces Of Brick Work Or Concrete Surfaces Including Mixing Of Liquid Water Proofing Compound As Per Manufacturing Instructions And Finished The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And Directed.Note : Wpc Will Be Mearsured And Paid Seperately. 74 M&L For Preparation Of New Steel Or Iron Surfaces Over 10 Cm In Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed. 75 M & L For Two Coats Of Cement Base Paint Over A Coat Of Alkali Resistant Primer On Newly Plastered Surfaces Of Walls Including Preperation Of New Surfaces Complete All As Specified And Directed. 76 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And Directed. 77 M & L For Hardcore Broken Stone Of Gauge N Exc. 63Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed. 78 M & L For 100 Mm Thick Cement Concrete Type D-2, 1:4:8 ( 40Mm Graded Stone Aggregate ) Complete All As Specified And Directed. 79 M & L For 25Mm Cement Concrete Type B-1, 1:2:4 ( 20Mm Graded Aggregate ) Complete All As Specified And Directed. 80 S & F Coloured Vetrified Ceramic Tiles 10 Mm Thick ( Square / Rectangular ) Polished Area Of Each Tile Exceeding 0.36 Sqm But Not Exceeding 0.42 Sqm In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cemeent To Match Incl 15 Mm Screed Bed In Cm 1:6 Complete All As Specified And Directed. 81 M & L For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Theincluding Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 82 M & L For Mild Steel Tmt Bars 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Theincluding Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 83 Supply Fabricate & Fix In Position Anodised Aluminium Powder Coated ( Minimum Thickness Of Powder Coating 50 Micron Of Approved Colour ) Door Shutter With Frame, Partly Glazed With 5 Mm Thick Tinted Glass And Partly Panelled With 9 Mm Thick Prelaminated Particle Board With Both Side Decorative Laminated Including Rubber Bead Joining Cleat For Fixing In Position, Aluminium Door Handle 150Mm Size, Aluminium Barrel Tower Bolt 200Mm Size Etc All As Specified Below Complete All As Specified And Directed. ( A ) Frame ( Top & Side ) Section Shall Of Size 101.60 X 44.75 X 2.4 Mm ( Section No 14021 ) ( B ) Vertical Members Of Shutter Section Shall Be Be Of Size 85.00 X 44.45 X 2.00 Mm ( Section No 19560 ) ( C ) Top Members Of Shutter Section Shall Be Be Of Size 83.50 X 44.45 X 2.00 Mm ( Section No 19581 ) ( D ) Lock Rail ( Middle Member ) Of Shutter Section Shall Be Be Of Size 150.00 X 44.45 X 3.00 Mm ( Section No 19596 ) ( E ) Bottom Members Of Shutter Section Shall Be Be Of Size 150.00 X 44.45 X 3.10 Mm ( Section No 19584 ) ( F ) Glazing Clip For Securing Glass Of Shutters Shall Be Be Of 0.80 Mm Thick ( Section No 19370 ) . 84 Supply Fabricate & Fix In Position Anodised Aluminium Powder Coated ( Minimum Thickness Of Powder Coating 50 Micron ) Three Track Window ( Two Shutters Glazed & One Shutters Wiregauge ) With Frame, Glazed With 4 Mm Thick Tinted Glass And, Wire Gauge With Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.40 Mm Including Rubber Bead Joining Cleat For Fixing In Position, Concelled Type Lock For All Three Shutter, Pvc Roller Etc All As Specified Below, Including Provn Of Locking Device In Each Shutter And Taking Down Of Old Steel / Wooden Windowcomplete All As Specified And Directed. ( A ) Frame ( Top & Side ) Section Shall Of Size 92.00 X 31.75 X 1.50 Mm ( Section No 20831 ) ( B ) Frame ( Bottom ) Section Shall Of Size 92.00 X 31.75 X 1.50 Mm ( Section No 20832 ) ( C ) Top & Side Members Of Shutter Section Shall Be Be Of Size 18.00 X 40.00 X 1.55 ( Section No 20738 ) ( D ) Shutter Interlock Section Shall Be Be Of Size 18.00 X 40.00 X 1.45 ( Section No 20737 ) ( E ) Bottom Members Of Shutter Section Shall Be Be Of Size 18.00 X 40.00 X 1.55 ( Section No 20736 ) ( F ) Member For Wire Gauge Shutter Shall Be 18.00 X 43.50 X 1.35 ( Section No 20791 ) . 85 S&F Aluminium ( Powder Coated With Approved Colour With Minimum Powder Coating Not Less Than 50 Micron ) Ventilator, Partialy Glazed And Partialy Louvers, Outer Frame & Mullionfabricated With Aluminium Section Of Size 82.50 Mm X 38.00 Mm X 1.70 Mm Thick ( Cat No 20036 ) , Half Portion Glazed With 4 Mm Thick Frosted Glass Including Rubber Beading, & Glazing Clip, Half Portaion Louvers Of 80 Mm Wide & 4 Mm Thick Frostade Glass Including Aluminium Louver Patti Including S.S Wire Gauge Of Fixing Of 0.36Mm Dia And 1.40 Width Of Aparture With 25X3mm Think Aluminium Strip With Screw To Upper Half Portion Of Ventilator All Fitting & Fixture And Fixed In Position Including Taking Down Old Ventilator Complete. Note:- ( I ) Section No Given Above Are Of Make Jindal, Contractor May Use Similar Section Of Other Make Mention In Appx B 86 Taking Down Carefully ( Copper / Aluminum ) Unsv Point Wiring Complete Of Any Type ( Batten / Surface Conduit Or Concealed ) For Light Point, Fan Point, Bell Point, Socket Point Or Power Point Includingfixture And Fitting Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting Etc. Removing Material For Taking Credit And Making Good The Disturbed Surfaces Of Wall / Floor Or Ceiling To Match With Existing Surface And Finishing The Surfaces With Distemper / White Washing / Colour Washing As Per Existing Complete All As Specified And Directed. 87 Taking Down Carefully By Unscrewing From Main Switch Boards / Cut Out Boxes / Mcb Dbs / Complete Sealing The Cable End And Making Good Disturbed Surface By Walls Etc Complete All As Specified And Directed. 88 Taking Down Carefully By Unscrewing From Fitting And Fixtures Such As Ceiling Fittings, Bulk Head Fittings, Tube Light Fittings, Street Light, Floodled Lights Etc Complete All As Specified And Directed. 89 M&L For Point Wiring With Pvc Insulated And Unsheathed Multi Stranded Frls Copper Conductor Single Core 1.5Sqmm ( Nominalarea ) Cable Using Approved Colour Code As Per Is Drawing In And Incl Pvc Casing And Capping With All Accessories Suitable Formodular Type Fitment Including Joint Boxes, Terminal Boxes Etc Complete Along With Copper Earth Wire Pvc Insulated & Unsheathed Multi Stranded ( Frls ) Copper Conductor Cableof Size 1.5Sqmm As Continuous Earth Wire Connected To Common Earth And Earth Dolly Complete All As Specified And Making Good Disturbed Surfaces Of Wall, Floor Or Ceiling With Plaster And Finishing The Surfaces With Distemper / White Washing / Colour Washing To Match With The Existing Surface Complete All As Specified And Directed.Note: Modular Metal Boxes Will Be Measured & Paid Seperately. 90 One Light Point / Fan Point Controlled By Oneswitch 91 One 3 Pin Socket Outlet 5Amps On The Same Board With Other Switches 92 One 3 Pin 5 Amp Socket Out Let Controlled By One Switch Onindependent Board 93 One Bell / Buzzer Point Controlled By One Bellpush 5 Amp On The Same Board With Other Switches Or Independent 94 M&L For Point Wiring For Power Point With Pvc Insulated And Unsheathed Multi Stranded Frls Copper Conductor Single Core 2.5Sqmm ( Nominalarea ) Cable Using Approved Colour Code As Per Is Drawing In And Incl Pvc Casing And Capping With All Accessories Suitable Formodular Type Fitment Including Joint Boxes, Terminal Boxes Etc Complete Alongwith Copper Earth Wire Pvc Insulated & Unsheathed Multi Stranded ( Frls ) Copper Conductor Cableof Size 2.5 Sqmm As Continuous Earth Wire Connected To Common Earth And Erth Dolly Complete All As Specified And Making Good Disturbed Surfaces Of Wall, Floor Or Ceiling With Plaster And Finishing The Surfaces With Distemper / White Washing / Colour Washing To Match With The Existing Surface Complete All As Specified And Directed.Note : Modular Metal Flush Boxes Will Be Measured & Paid Seperately. 95 All As Per Item No 90 Above But Wiring With 4.0 Sqmm Multi-Stranded Copper Conductor Pvc Insulated, Unsheathed Fire Retardant Low Smoke, Cable And 4.0Sqmm Multi-Stranded Copper Conductor Pvc Insulated, Unsheathed Fire Retardant Low Smoke, Cable As Continous Earth Wire Connected To Common Earth Dolly For 15 Amps Multipurpose Socket Outlet On Independent Board, Controlled With One Way Switch. 96 M & L For Switch Piano Flush Type Single Pole, One Way 5 Amp 230 V Complete All As Specified And Directed. 97 M & L For Switch Socket Combination 2 In 1, 6A Flush Type Complete All As Specified And Directed. 98 M & L For Switch Socket Combination 2 In 1, 3 Pin, 6 And 16 Amp Flush Type Universal Complete All As Specified And Directed. 99 M & L For Socket Outlet 2 In 1, 3 Pin, 5A 100 M & L For Switch Piano Flush Type Single Pole, One Way 15 Amp 101 M&L For Socket Outlet 2 In 1, 3 Pin, 5 And 15 Amp Flush Type 102 S & F Industrial Type Plug & Socket Board Sp & N Enclosure With 2 Pole And Earth Metal Plug & Socket Complete With 10 Amp Mcb Sp 103 Supply And Fixin Repair Stepped Type Electronic Fan Refulator Flush Typeon The Existing Phenolic Laminated Sheet Etc. Complete All As Specified And Directed. 104 M&L For Ceiling Rose Ceiling Rose, 2 To 3 Terminalpvc / Polycarbonate, Isolated Body Type Suitable For Ac 230 Volts Complete All As Specified And Directed. 105 M & L For Bell Push 5 Amp 230 Volts Complete All As Specified And Directed. 106 M & L For Bellac 230 Volts, Single Pole Complete All As Specified And Directed. 107 S&F Energy Efficient Led Tube Light Fitting Integrated Batten Type With Built In Led Chip & Integral Led Driver 21 Watt, Channel Housing & Diffuser Of Length 1200 Mm ( Approx. ) With All Accessories, Fixing Arrangement Internally Pre-Wired, Fixed In Position & Connecting Complete All As Specified And Directed. Make -Wipro Cat Part No.Ll20-221-Xxx-65Ne3 / Philips Cat Part No. Bn O21c Led120s Psu Cdl / Nw Gr ( 6500K ) / Havells Or Equivalent Makes Mentioned In Appx B To Ps. 108 S&F Energy Efficient Led Tube Light Fitting Integrated Batten Type With Built In Led Chip & Integral Led Driver 10 Watt, Channel Housing & Diffuser Of Length 600 Mm ( Approx. ) With All Accessories, Fixing Arrangement Internally Pre-Wired, Fixed In Position & Connecting Complete All As Specified And Directed.Make Wipro Cat Part No.Ll20-111-Xxx-65Ne3 / Philips Cat Part No. Bn O21led10s ( 6500K ) / Havells Or Equivalent Makes Mentioned In Appx B To Ps. 109 S&Fbuilding Security In Repair Led Light Fitting 35 Watt, System Efficiency Not Less Than 100 Lumen / Watt, Ip66 Protection, Consisting Of High / Low Voltage Cut Off, Maintenance Free Isolated Electronic Driver Circuits, Low Thd, Pmma Grade High Quality Transmittance Lens, Epoxy Powder Coated Die Cast Aluminum Housing With Weather Proof Gasket For Lamp & Driver Compartment, Heat Resistance Toughened Glass Fitted In Cast Aluminum Housing With Ss Screws, Fixed On Existing Bracket & Connecting Including Taking Down Old Light Fitting Of Any Description Complete All As Specified And Directed.Make : Wipro, Cat Part No Lr02-291-Xxx-57-Xx Or Equivalent In Philips / Wipro Or Equivalent Makes Mentioned In Appx B To Ps. 110 Supply Andfixexhaust Fan 250 Mm Sweep Ac, 240 Volts, Plastic Body, Fixed As Per Manufacturer Instruction, Connecting With And Including 1.5 Sqmm Copper Conductor, Pvc Insulated And Pvc Sheathed Three Core Cable Including Making Sutable Size Hole In Brick / Pcc Block / Stone Masonary Wall Built In Cement Mortar And Making Good Disturbed Surface Complete All As Specified And Directed.Make :-Bajaj / Usha / Crompton / Usha 111 Taking Down Carefully ( Copper / Aluminum ) Sub Main Wiring Complete Of Any Type ( Batten / Surface Conduit Or Concealed ) For Socket Point Or Power Point Complete With All Fittings Such As Switches Sockets Pendants Etc Complete And Making Good Disturbed Surface Of Wall, Floor Or Ceiling With Plaster Of Tiles Or Roof Treatment Etc And Finishing The Surface With Distemper White Washing / Colour Washing To Match With The Existing Surface Complete All As Specified And Directed. 112 M&L Sub Main Wiring Using Pvc Insulated And Unsheathed Multi Stranded Frls Copper Conductorcable Using Approved Colour Code As Per Is Drawing In And Incl Pvc Casing And Capping Of Suitable Size With All Accessories And Making Good Disturbed Surfaces Of Wall, Floor Or Ceiling With Plaster And Finishing The Surfaces With Distemper / White Washing / Colour Washing To Match With The Existing Surface Complete All As Specified And Directed Of The Following Sizes Of Cables:- 113 Using Two Single Corepvc Insulatedfrls Cable 2.5 Sqmm Copper Conductor Multi Stranded And 2.5 Sqmm Copper Conductor Insulated Cable Using As Earth Wirenote :2 Runs Of 2.5Sqmm Copper Cable & 1 Run Of 2.5 Sqmm Copper Cable And One Run Of Casing & Caping Shall Be Measured As One Unit 114 Using Two Single Corepvc Insulatedfrls Cable 4 Sqmm Copper Conductor Multi Stranded And 4.0 Sqmm Copper Conductor Insulated Cable Using As Earth Wirenote :2 Runs Of 4Sqmm Copper Cable & 1 Run Of 4.0Sqmm Copper Cable And One Run Of Casing & Caping Shall Be Measured As One Unit 115 M & L For Distribution Board ( Db ) , Double Door ( Crca Sheet ) Dust And Vermin Proof Spn 4 Way With 200 Amps Rated Copper Busbar, Neutral Bar, Earth Bar And Cable Ties For Cable Management, Reversible Door For Ip 43 & Ip 54, Single Pole And Neutral 250 Volts, Flush To Wall Complete With Ip 54 Protection Complete All As Specified And Directed. Make : Legrand Model: Ip 54 Ik 09 507641Ekinox Or Equivalent Make Mentioned In Appx B To Ps. 116 M & L For Distribution Board ( Db ) , Double Door ( Crca Sheet ) Dust And Vermin Proof Spn 8 Way With 100 / 200 Amps Rated Copper Busbar, Neutral Bar, Earth Bar And Cable Ties For Cable Management, Reversible Door For Ip 43 & Ip 54, Single Pole And Neutral 250 Volts, Flush To Wall Complete With Ip 54 Protection Complete All As Specified And Directed. Make : Legrand Model: Ip 54 Ik 09 507641Ekinox Or Equivalent Make Mentioned In Appx B To Ps. 117 M&L For Mcb Single Pole & Neutral240 Volt C Curve 10 Ka ( 32 To 63 ) Amps Capacity Ip 20 Complete All As Specified And Directed. 118 M&L For Mcb Single Pole, 5 To 32 Amp 240 Volt B Curve 10 Ka, Ip 20 Complete All As Specified And Directed. 119 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick Burried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanised Earth Lead Wire Mm As 4.0Mm Dia Bymeans Of Bolts Nuts Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electricalplate No.3 Includingearth Pit In Pcc Concrete 1:2:4 Type B-1, Cast Iron Cover 10 Mm Thick Hinged To Ci Frame, Excavation And Earth Work In Any Type Of Soil And Including Protectionpipe 15Mm Dia And Water Pipe Gi Tubing 20Mmlight Grade With Funnel And Wire Mesh Connected To Earthling Test Point Complete All As Specified And Directed. Note: ( I ) Rates Are Inclusive Of 7.5M Long Gi Earth Wire 4.0Mm Dia ( Ii ) Rates Of Ci Frame, Rcc Pit Cover, Funnel And Wire Mesh Included In The Cost Of Item.
Contract Date: Feb 11, 2022 Contract Value : 12.50 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
West Bengal View Result →
26.
Defence #1772910 AOC
Tender For Provision Of Technical Storage Accn At Parma ( Chushul ) ; 1 Note: Schedule ‘A’ Part - I Toixare Prepriced By Mes. Bidders Shall Insert Their Lumpsum Amount In The Green Coloured Field Under Col- 6 Only. 2 Total Amount Of Sch A Part - I ( Buildings ) 3 Total Amount Of Sch A Part - Ii ( Internal Electrification ) 4 Total Amount Of Sch ‘A’ Part - Iii ( Protective Works ) 5 Total Amount Of Sch ‘A’ Part - Iv ( Area Drainage ) 6 Total Amount Of Sch ‘A’ Part - V ( Road ) 7 Total Amount Of Sch ‘A’ Part - Vi ( Hardstanding ) 8 Total Amount Of Sch ‘A’ Part - Vii ( External Electric Supply ) 9 Total Amount Of Sch ‘A’ Part - Viii ( Lightening Protection ) 10 Total Amount Of Sch A Part - Ix ( Site Clearance, Excavation And Earth Work ) 11 Sch A Part - X ( Dg Set ) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 5 Signifies This Fact Only 12 Supply & Installation Of Silent Cpcb Approved 10 Kva Tpdiesel Generating Set Having Diesel Engine Liquid Cooled, Electric Start, Four Stroke, Cold Starting, Tci Aspirated, Compression Ignition, Totally Enclosed Diesel Engine With Electronic Governor , Direct Coupled With 10 Kva Three Phase Alternator At 1500 Rpm, 0.8 Lagging Power Factor, Providing Three Phase 415Volts Suitable For 50 Hz, H Class Insulated Winding, Close-Direct-Coupled, Self-Excited And Self-Regulated Type, Screen Protected, Mounted On Rigid Ms Sheet Channel Base-Frame. The Alternator Shall Confirm To Is: 13364, Is: 4722, Bs5000, Iec: 34 And Suitable For Tropical Condition. Having Fitted Inside Canopy, Fabricated Out Of 1.6 Mm Thick Crca Sheet, Cubical Type, Totally Enclosed, Powder Coated, Control Panel And All Accessories In-Housed In A Acoustic Enclosure – Sound Proof Canopy. Make: Cummins / Kirloskar Green / Powerol / Mahindra & Mahindra / Crompton Greaves. 13 ( A ) Diesel Engine: - Adquate Capacity Of Diesel Engine As Accepted By The Accepting Officer Based On Manufacturers Technical Details Water Cooled To Drive Independently Above Alternator And After Considering Derating As Per Site Conditons After Generating And Reducing Power Consumed By Accessories Directly Coupled Through Flexible Coupling Multi Cylinder Multi Stroke Direct Injection, Cold Starting 1500 Rpm, As Per Relevant Isi / Bs - 5514 With An Overload Capacity Of 10% For Half An Hour In 12 Hours Continuous Running Complete With Standard Accessories All As Specified And Required For Safe Handling And Operation Salient Features Of Accessories Shall Be As Under :- 14 I ) Fly Wheel With Housingii ) Cooling System :- Moulded Radiator With Fan & Belts.Iii ) Cooling Water Pump : - Centrifugal Type Belt Driven.Iv ) Exhaust System :- Exhaust System Complete With Exhaust Piping Of 150Mm Dia With Ms Pipe Light Grade Upto & Outside And 1 Meter Away From The Enclosure, Covered With Asbestos Rope And Aluminium Foil Of Complete With In The Enclosure For Safe Exhaust Without Transforming Vibration To The Wall Of The Enclosure:Exhaust Gas Turbo Charger Typeexhaust Manifoldsilencer : Residual Typebellows 15 Iv ) Fuel System :- Fuel Injection System With Fuel Injectors, Fuel Injection Solenoid Switch Controlled By Electronic Governer For 1% Speed / Frequecy Regulation.Fuel Filtersfuel Hosesv ) Lub Oil System :-Lubricating Oil Filterlubricating Oil Pumpvi ) Air Intake System :- Air Intake Manifoldair Cleaner Dry Typevii ) Governer :- Electronic Governerviii ) Starting System :- Electric Self Starter With Maintenace Free Battary Including Battary Charging Alternator. 16 ( B ) Batteries :- Batteries Of Maintainence Free Of Capacity As Recommended By The Manufacturer Complete With Copper Conductor Multistranded Leads Of Suitable Length Fromself Starter To The Battery Terminals Complete With Initial Charge And Initial Fill Of Electrolyte All As Specified Of Make As Per Oem. ( C ) Starter Gear Ringstart And Stop Push Buttonignition Key / Switchhandling And Operation : Salient Features Of Accessories Shall Be As Under:Radiator With Blower Fancorrosion Inhibitor Coolantpaper Element Filters For Fuel, Lub Oil And By Pass.Electronic Governer Controlled Direct Fuel Injection Systemfly Wheel Housing And Fly Wheel. 17 ( D ) Generator Monitoring Control Panel : - Comprising Of All Standard Items As Mentioned Under This Schedule Or As Per Standardpractice Iginiton Key Switch And Start / Stop Arrangement, Indications For Engine Parameters, Hour Run Meter, Rpm Meter, Engine Oil Pressure Indicator, Water / Coolent Temparature Indicator, Battery Volt Display Including Suitable Size Mccbs And Multifuction Meter.Xi ) Safety Controls : - Engine Low Lube Oil Pressure High Water Temperature And Over Speeding Of Engine.Xii ) Coupling Arrangement : - Flexible Coupling, Fly Wheel To Suit Flexible Coupling.Xiii ) Accessories :- Avm Pads Built Or Separetely Mounted To Manufacturer Base Frames.Xiv ) Base Frame : - Made Out Of Ismc 250 Of Sturdy Design Made Of Ms Channel With Necessary Reinforcement And Predetermined Holes.Xv ) Ms Pipe Line To And From The Fuel Tank To The Dg Set. 18 ( E ) Alternator :-Standard Design Alternator Rated At 10 Kva, Net Output At Site After Considering Derating As Per Site Conditions At 0.8 ( Lag ) Power Factor Ac, 3 - Phase 4 - Wire 415 Volts 50 Hz, 1500 Rpm, Self Exicited Self Regulated Screen Protected Drip Proof Ip 23 Enclosure Brushless Design With Widing In Pole Faces, Insulating Class H And Voltage Regulation Of+ / - 1% At Rated Voltage From No Load To Full Load. The Alternator Shall Be Conforming To Bs 2613 / 5000 And Shall Be In Position To Generate Supply With Frequecy Regulation With In + / - 1% Tolerance. The Alternator Will Be Suitable For Tropical Climate And Shall Generally Confirm To Bs - 2613 / 5000 / Is - 4722.I ) Insulation Class - HIi ) Temparature Rise Class - HIii ) Excitation : Self Excitediv ) Regulation Performance: The Voltage Is Kept Constant With + / - 1%, Manual Voltage Adjustment Within + / - 5% .V ) Frequency Regulation + / - 1% 19 ( F ) Civil Works :-All Civil Works Including Pcc Platform As Per ManufactureS Design Also 30 Cm Above The Ground. The Depth Of The Foundation And Pcc As Recommended By The Manufacturer. ( G ) Rubber Mattingof Lv Grade 19Mm Thick Of Suitable Size Chequered Type Isi Marked To Be Laid In Front Of Control Panel Should Be Provided.Note:- The Contractor Shall Arrange For Artificial Load For Testing For Final Testing Of Dg Set At Site And The Cost Is Deemed To Be Included In Quoted Rate ( H ) Accoustic Enclosure:- Manufactured By Oem Suitable For 10 Kva Dg Set. ( I ) Nal Approved As Per Cpcb ( Ii ) It Should Be As Per Latest Rules And Regulations Of Ministry Of Environment And Forest And Pollution Control Board. 20 ( Iii ) The Generating Setbatteries And Control Panel Should Be Inside The Enclosure. ( Iv ) Fuel Tank Should Be Outside The Enclosure In The Sub Station Building.V ) The Accoustic Should Be Composite In Construction And Fully Assembled Integral Unit.Vi ) The Battaries Should Be Placed Inside The Enclosure Beside The Dg Set On A Suitable Insulatedplatform.Vii ) The Dg Set Should Be Provided With External Emergency Stop Push Button.Viii ) The Enclosure Should Be Suitably Illuminated By Suitable Capacity Of Ledfittings.Xi ) The Noise Level Should Be 75 Db At 1M Under Free Field Conditions.Xii ) The Accoustic Enclosure Parts Shall Be Of Powder Coated After Pre Treatment Process. The Powder Coating Shade Should Be Genset Green. The Base Frame Should Be Painted With Epoxy Based Black Shade. 21 Xiii ) Fuel Tank As Per Manufacturer Recommendation With Inlet And Outlet Connections And Fuel Level Indicator.Xiv ) Base Frame Made Out Of Suitable Ms Channel Duly Reinforced And Provided With Adequate Numbers Of Anti-Vibration Pads To Ensure Minimum Vibration As Recommended By Manufacturer.Notes : - ( I ) Thegenerator Set Prime Mover Will Produce At Least 11 Bhp On 10 Kva. ( Ii ) Rate Quoted Shall Be Deemed To Be Inclusive Of Cable And Terminations Form Generator To The Amf Panel, With Necessary Holes To Wall Including Making Good To Disturbed Surfaces So As To Match With The Existing Finishes All As Specified And Directed. ( Iii ) The Quoted Rate Shall Be Deemed To Be Inclusive Of First Filling Of Lubricant Oil. ( Iv ) The Quoted Rate Shall Be Deemed To Be Inclusive Of 12 Hours Test Run At Site Including Of Half An Hour On 10% Overload In Presence Of Representative Detailed By Accepting Officer; Including Fol, All Arrangements Are To Be Made By The Contractor For Tests. 22 Supply & Installation Of Silent Cpcb Approved 5 Kva Tpdiesel Generating Set Having Diesel Engine Liquid Cooled, Electric Start, Four Stroke, Cold Starting, Tci Aspirated, Compression Ignition, Totally Enclosed Diesel Engine With Electronic Governor, Direct Coupled With 10 Kva Three Phase Alternator At 1500 Rpm, 0.8 Lagging Power Factor, Providing Three Phase 415Volts Suitable For 50 Hz, H Class Insulated Winding, Close-Direct-Coupled, Self-Excited And Self-Regulated Type, Screen Protected, Mounted On Rigid Ms Sheet Channel Base-Frame. The Alternator Shall Confirm To Is: 13364, Is: 4722, Bs5000, Iec: 34 And Suitable For Tropical Condition. Having Fitted Inside Canopy, Fabricated Out Of 1.6 Mm Thick Crca Sheet, Cubical Type, Totally Enclosed, Powder Coated, Control Panel And All Accessories In-Housed In A Acoustic Enclosure – Sound Proof Canopy. Make: Cummins / Kirloskar Green / Powerol / Mahindra & Mahindra / Crompton Greaves. 23 ( A ) Diesel Engine: - Adquate Capacity Of Diesel Engine As Accepted By The Accepting Officer Based On Manufacturers Technical Details Water Cooled To Drive Independently Above Alternator And After Considering Derating As Per Site Conditons After Generating And Reducing Power Consumed By Accessories Directly Coupled Through Flexible Coupling Multi Cylinder Multi Stroke Direct Injection, Cold Starting 1500 Rpm, As Per Relevant Isi / Bs - 5514 With An Overload Capacity Of 10% For Half An Hour In 12 Hours Continuous Running Complete With Standard Accessories All As Specified And Required For Safe Handling And Operation Salient Features Of Accessories Shall Be As Under :- 24 I ) Fly Wheel With Housingii ) Cooling System :- Moulded Radiator With Fan & Belts.Iii ) Cooling Water Pump : - Centrifugal Type Belt Driven.Iv ) Exhaust System :- Exhaust System Complete With Exhaust Piping Of 150Mm Dia With Ms Pipe Light Grade Upto & Outside And 1 Meter Away From The Enclosure, Covered With Asbestos Rope And Aluminium Foil Of Complete With In The Enclosure For Safe Exhaust Without Transforming Vibration To The Wall Of The Enclosure:Exhaust Gas Turbo Charger Typeexhaust Manifoldsilencer : Residual Typebellows 25 Iv ) Fuel System :- Fuel Injection System With Fuel Injectors, Fuel Injection Solenoid Switch Controlled By Electronic Governer For 1% Speed / Frequecy Regulation.Fuel Filtersfuel Hosesv ) Lub Oil System :-Lubricating Oil Filterlubricating Oil Pumpvi ) Air Intake System :- Air Intake Manifoldair Cleaner Dry Typevii ) Governer :- Electronic Governerviii ) Starting System :- Electric Self Starter With Maintenace Free Battary Including Battary Charging Alternator. 26 ( B ) Batteries :- Batteries Of Maintainence Free Of Capacity As Recommended By The Manufacturer Complete With Copper Conductor Multistranded Leads Of Suitable Length Fromself Starter To The Battery Terminals Complete With Initial Charge And Initial Fill Of Electrolyte All As Specified Of Make As Per Oem. ( C ) Starter Gear Ringstart And Stop Push Buttonignition Key / Switchhandling And Operation : Salient Features Of Accessories Shall Be As Under:Radiator With Blower Fancorrosion Inhibitor Coolantpaper Element Filters For Fuel, Lub Oil And By Pass.Electronic Governer Controlled Direct Fuel Injection Systemfly Wheel Housing And Fly Wheel. 27 ( D ) Generator Monitoring Control Panel : - Comprising Of All Standard Items As Mentioned Under This Schedule Or As Per Standardpractice Iginiton Key Switch And Start / Stop Arrangement, Indications For Engine Parameters, Hour Run Meter, Rpm Meter, Engine Oil Pressure Indicator, Water / Coolent Temparature Indicator, Battery Volt Display Including Suitable Size Mccbs And Multifuction Meter.Xi ) Safety Controls : - Engine Low Lube Oil Pressure High Water Temperature And Over Speeding Of Engine.Xii ) Coupling Arrangement : - Flexible Coupling, Fly Wheel To Suit Flexible Coupling.Xiii ) Accessories :- Avm Pads Built Or Separetely Mounted To Manufacturer Base Frames.Xiv ) Base Frame : - Made Out Of Ismc 250 Of Sturdy Design Made Of Ms Channel With Necessary Reinforcement And Predetermined Holes.Xv ) Ms Pipe Line To And From The Fuel Tank To The Dg Set. 28 ( E ) Alternator :-Standard Design Alternator Rated At 5 Kva, Net Output At Site After Considering Derating As Per Site Conditions At 0.8 ( Lag ) Power Factor Ac, 3 - Phase 4 - Wire 415 Volts 50 Hz, 1500 Rpm, Self Exicited Self Regulated Screen Protected Drip Proof Ip 23 Enclosure Brushless Design With Widing In Pole Faces, Insulating Class H And Voltage Regulation Of+ / - 1% At Rated Voltage From No Load To Full Load. The Alternator Shall Be Conforming To Bs 2613 / 5000 And Shall Be In Position To Generate Supply With Frequecy Regulation With In + / - 1% Tolerance. The Alternator Will Be Suitable For Tropical Climate And Shall Generally Confirm To Bs - 2613 / 5000 / Is - 4722.I ) Insulation Class - HIi ) Temparature Rise Class - HIii ) Excitation : Self Excitediv ) Regulation Performance: The Voltage Is Kept Constant With + / - 1%, Manual Voltage Adjustment Within + / - 5% .V ) Frequency Regulation + / - 1% 29 ( F ) Civil Works :-All Civil Works Including Pcc Platform As Per ManufactureS Design Also 30 Cm Above The Ground. The Depth Of The Foundation And Pcc As Recommended By The Manufacturer. ( G ) Rubber Mattingof Lv Grade 19Mm Thick Of Suitable Size Chequered Type Isi Marked To Be Laid In Front Of Control Panel Should Be Provided.Note:- The Contractor Shall Arrange For Artificial Load For Testing For Final Testing Of Dg Set At Site And The Cost Is Deemed To Be Included In Quoted Rate ( H ) Accoustic Enclosure:- Manufactured By Oem Suitable For 5 Kva Dg Set. ( I ) Nal Approved As Per Cpcb ( Ii ) It Should Be As Per Latest Rules And Regulations Of Ministry Of Environment And Forest And Pollution Control Board. 30 ( Iii ) The Generating Setbatteries And Control Panel Should Be Inside The Enclosure. ( Iv ) Fuel Tank Should Be Outside The Enclosure In The Sub Station Building.V ) The Accoustic Should Be Composite In Construction And Fully Assembled Integral Unit.Vi ) The Battaries Should Be Placed Inside The Enclosure Beside The Dg Set On A Suitable Insulatedplatform.Vii ) The Dg Set Should Be Provided With External Emergency Stop Push Button.Viii ) The Enclosure Should Be Suitably Illuminated By Suitable Capacity Of Ledfittings.Xi ) The Noise Level Should Be 75 Db At 1M Under Free Field Conditions.Xii ) The Accoustic Enclosure Parts Shall Be Of Powder Coated After Pre Treatment Process. The Powder Coating Shade Should Be Genset Green. The Base Frame Should Be Painted With Epoxy Based Black Shade. 31 Xiii ) Fuel Tank As Per Manufacturer Recommendation With Inlet And Outlet Connections And Fuel Level Indicator.Xiv ) Base Frame Made Out Of Suitable Ms Channel Duly Reinforced And Provided With Adequate Numbers Of Anti-Vibration Pads To Ensure Minimum Vibration As Recommended By Manufacturer.Notes : - ( I ) Thegenerator Set Prime Mover Will Produce At Least 6 Bhp On 5 Kva. ( Ii ) Rate Quoted Shall Be Deemed To Be Inclusive Of Cable And Terminations Form Generator To The Amf Panel, With Necessary Holes To Wall Including Making Good To Disturbed Surfaces So As To Match With The Existing Finishes All As Specified And Directed. ( Iii ) The Quoted Rate Shall Be Deemed To Be Inclusive Of First Filling Of Lubricant Oil. ( Iv ) The Quoted Rate Shall Be Deemed To Be Inclusive Of 12 Hours Test Run At Site Including Of Half An Hour On 10% Overload In Presence Of Representative Detailed By Accepting Officer; Including Fol, All Arrangements Are To Be Made By The Contractor For Tests. 32 Sch A Part - Xi ( Miscellaneous B / R And E / M Works ) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 5 Signifies This Fact Only 33 Supply And Fixsign Boards Of Size 1200Mm X 1200Mm Made Out Of 1Mm Thick Plain Black Sheet Fixed Over Ms Angle Iron 25 X 25 X 5Mmframe Work, Height Of Frame 2700 Mmfrom Gl All Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Covering The Board With Reflective Sheet And Writing Letters Over It Of Size As Approved By Gecomplete All As Directed.Note :- Excavation In Post Holes And Pcc 1:2:4 Type B1 For Fixing The Sign Board Is Deemed To Be Inclusive In The Quoted Rate. 34 Supply And Fixunhd Fire Symbols Sign Boards Of Size 1200Mm X 1200Mm Made Out Of 1Mm Thick Plain Black Sheet Fixed Over Ms Angle Iron 25 X 25 X 5Mmframe Work, Height Of Frame 2700 Mmfrom Gl All Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Covering The Board With Reflective Sheet And Writing Letters Over It Of Size As Approved By Ge Complete All As Directed.Note :- Excavation In Post Holes And Pcc 1:2:4 Type B1 For Fixing The Sign Board Is Deemed To Be Inclusive In The Quoted Rate. 35 Supply Only Frgdunnage Blocks Of Size 30Cm X 30Cm X 20Cm All As Specified And As Directed. 36 Supply And Fixing Totally Enclosed Flame Proof, Weather Proof Led Light Fitting 2X20 Watts, 1200Mm With Aluminium Extruded And Aluminium Heat Sink, System Lumen Efficiency =100 Lm / W Operating Voltage Between 140-270 V Ac, Power Factor More Than 0.90%, Led Driving Current < 70% Of Rated Maximum Forward Current, Thd Less Than 20%, Cri More Than 80%, Luminaire Integral Driver With 2Kv Surge Protection, Over Load Protection, No Load Protection And Bis Marking ( R No. For Driver ) , Driver Certification Iec64347-2-13 Is ( 15885 ) , Over All Electrical Efficiency More Than 90%, Driver Electrical Efficiency Will Be > 85%, With 2 Year Warranty All As Specified And Directed. Make : Shyaam, Crompton, Sudhir, Bajaj, Baliganote :- Mounting Of The Bracket For Light Fitting In The Roof Shall Be Done At The Time Casting Of Slab. 37 Supply And Fixing Flame Proof 12 Way Distribution Board For Mounting Mcb / Rcbo / Elcb Etc. As Per Is Specification And Cmri Approved, Factory Made, Fabricated Out Of Cast Aluminium Alloy Lm-06 Grey Epoxy Powder Coated Finish, Fitted With Din Channel Neutral Link, Earth Links And 200 Amps Rated Bus Bar. The Db Shall Be Having Ip-65 Protection. The Dbs Shall Also Be Consisting And Including The Following:- ( A ) Mcb Spn40 Amps, 240 Volts Ac 50 Hz- 01 No. ( B ) Mcb Sp10 Amps, 240 Volts Ac 50 Hz- 10 Nos. Make : Shyaam, Crompton, Sudhir, Bajaj, Baliga 38 Supply And Fix Flame Proof Flexible Metalic Hose Conduit 20 Mm Dia All As Specified And Directed. 39 Supply, Fixing, Installation, Testing And Commissioning Of Lt Panel Of Size 0.9M X 0.9M X 0.6M, Outdoor Type Cubical Shape Made Out Of Crca Sheet 3.15 Mm Thick , Factory Fabricated With Front And Back Openabe Double Door With Locking Arrangement, Cpri Approved, Suitable For 3 Phase, 4 Wire System 415 Volts, 50 Hz, Ac Supply System, Aluminium Bus Bar For Phases And Neutral, Powder Coated, Provided With Suitable Gasket To Make It Dust And Vermin Proof, Provision For Ventilation, M S Angle Iron 50X50x6mm Frame Support And Four Legs All Powder Coated Not Less Than 100 Microns Thickness, Grouting Of Legs In Pcc 1:3:6 Type C1 Foundation Of Suitable Size As Per ManufacturerS Directions And Height Not Less Than 30 Cm From The Ground Level, Panelto Accomodate The Items Mentioned Belowand Having Seperate Compartment / Chambers For Cable Gallery, Busbar, Switch Gear Etc All As Specified And Comprising Of Following Including Necessary Cable Connections To The Mcbs, Mccbs, Voltmeter, Ammeter And Cable Lugs Etc. Complete All As Directed: - 40 ( A ) Aluminium Bus Bar, 3 Phase, 4 Wire, Ac Supply System 50 Hz Mounted On Epoxy Based Post Insulators, Including Drilling Hole For Cable Connection, Rating Of Bus Bar 50 Amps. ( B ) Incoming Mccb 16 Amp, 4Pole 16 Ka, 415 Volt With Adjustable Thermal And Fixed Magnetic Release - 01 No ( C ) Outgoing Mcb Spn 3 Amp 6 Ka C, 240 Volts, - 02 Nos ( 01 Standby ) ( D ) Outgoing Mcb Spn 3 Amp 16 Ka 440 V - 01 Nos ( Timer ) ( E ) Outgoing Mcb Tpn 10 Amp 16 Ka 440 V - 02 Nos ( Siren+Spare ) ( F ) Ammeter Digital Type 0 - 50 Amps, 3 Ph With In Built Selector Switchwith Suitable Rating Cts -01 Setmake: Dip / Ae / Imp / Nsd 41 ( G ) Voltmeter, Digital Type 0 - 500 Volt, 3 Ph With In Built Selector Switchwith Selector Switch -01 Setmake: Dip / Ae / Imp / Nsd ( H ) All Accessories Prewired With Appropriate Size Copper Strip Or Wire Thimbles Etc. ( J ) Phase Indicating Lamps Led Type ( Ryb ) - 01 Set 42 Supply, Fixing, Installation, Testing And Commissioning Of Lt Panel Of Size 0.9M X 0.9M X 0.6M, Outdoor Type Cubical Shape Made Out Of Crca Sheet 3.15 Mm Thick , Factory Fabricated With Front And Back Openabe Double Door With Locking Arrangement, Cpri Approved, Suitable For 3 Phase, 4 Wire System 415 Volts, 50 Hz, Ac Supply System, Aluminium Bus Bar For Phases And Neutral, Powder Coated, Provided With Suitable Gasket To Make It Dust And Vermin Proof, Provision For Ventilation, M S Angle Iron 50X50x6mm Frame Support And Four Legs All Powder Coated Not Less Than 100 Microns Thickness, Grouting Of Legs In Pcc 1:3:6 Type C1 Foundation Of Suitable Size As Per ManufacturerS Directions And Height Not Less Than 30 Cm From The Ground Level, Panelto Accomodate The Items Mentioned Belowand Having Seperate Compartment / Chambers For Cable Gallery, Busbar, Switch Gear Etc All As Specified And Comprising Of Following Including Necessary Cable Connections To The Mcbs, Mccbs, Voltmeter, Ammeter And Cable Lugs Etc. Complete All As Directed: - 43 ( A ) Aluminium Bus Bar, 3 Phase, 4 Wire, Ac Supply System 50 Hz Mounted On Epoxy Based Post Insulators, Including Drilling Hole For Cable Connection, Rating Of Bus Bar 50 Amps. ( B ) Incoming Mccb 6 Amp, 4Pole 16 Ka, 415 Volt With Adjustable Thermal And Fixed Magnetic Release - 01 No ( C ) Outgoing Mcb Spn 3 Amp 6 Ka C, 240 Volts, - 02 Nos ( 01 Standby ) ( D ) Outgoing Mcb Tpn 3 Amp 16 Ka 440 V - 03 Nos ( Timer 2 & 3 +Spare ) ( E ) Ammeter Digital Type 0 - 50 Amps, 3 Ph With In Built Selector Switchwith Suitable Rating Cts -01 Setmake: Dip / Ae / Imp / Nsd 44 ( F ) Voltmeter, Digital Type 0 - 500 Volt, 3 Ph With In Built Selector Switchwith Selector Switch -01 Setmake: Dip / Ae / Imp / Nsd ( G ) All Accessories Prewired With Appropriate Size Copper Strip Or Wire Thimbles Etc. ( H ) Phase Indicating Lamps Led Type ( Ryb ) - 01 Set 45 Supply And Fixing Of 45W Led Street Light With System Lumen Efficacy =120 Lm / W Operating Voltage Between 120-270Vac, Multistage Isolated Potted Driver, Driver Will Comply For 440Vac Operation ( Will Sustain For 4 - 6 Hrs Continuously ) , Driver Will Have Cut Off At > 300 Vac, Ip66 Protection, Power Factor More Than 0.95%, Of Rated Maximum Forward Current, Luminaire Integral Driver With 5Kv Surge Protection, Over Load Protection, No Load Protection And Bis Marking ( R No. For Driver ) , Connecting With Pvc Insulated Copper Cable Of Size 1.5 X 3 Sqmm As Per Is 10322 And With At Least 2 Year On Site Warranty Without Any Condition Complete All As Specified And Directed.Make :- Philips / Wipro / Osram 46 Suppy And Fixing Junction Box Of Size 30Cm X 15 Cm X 8 Cm, Made Out Of 3.15 Mm Thick Ms Sheet Powder Coated With Locking Arrangementincluding One Mcb Sp 6 Amps, 02 Nos Bus Bar Of Suitable Size, With Suitable Number Of Holes And Ms Clamps To Fix On Street Light Pole All As Specified And Directed. 47 Supply And Fixing Street Light Digital Timer Distribution Board With Mcb Tpn 40 Amp -2 Nos, 415 Volt, 3 Phase Contactor 40 Amps, Digital Timercontrolled By Mcb, Time Switch 415V, 3 Phase, 20 Amp Rating With Contactor Complete Fixed Inside Steel Enclosure Withclamps & Brackets, All As Specified And As Directed. 48 Supply And Fix Steel Tublar Swaged Poles Erected Truly Vertical Or Planted As Strut Complete Withcast Iron Base Plate Welded To Pole, Finial Taper Plug, Bolts, Nuts & Screws, Poles Made Out Of Erw Ms Tubing Conforming To Is:1161 & Is:2713, Type 410 Sp- 80 ( 16 M Long ) Including Drilling Of Holes Of Required Size For Fixing Of Cross Arms, Painting The Exposed Surfaces Of Pole With Two Coats Of Aluminium Paint Over A Coat Of Zinc Chrome Primer And Two Coats Of Black Bitumenous Paint Internally & Portion Embedded In Concrete, Making Five Black & White Bands At Lower Portion Of Pole Each 300 Mm Wide Alternatley, And Marking Pole No. With Black Paint At Suitable Height And Painting Of Coping With Two Coats Of Synthetic Enemal Paint Complete All As Specified And Directed.Note :- Excavation And Earth Work, Pcc In Foundation And Coping Shall Be Measured And Paid For Separetely.
Contract Date: Oct 23, 2023 Contract Value : 19.99 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
Jammu And Kashmir View Result →
Contract Date: Aug 26, 2021 Contract Value : 7.25 Crore
Government Departments No of Bidders 5
Madhya Pradesh View Result →
TenderDetail