View Bid Results For Metering Pumps Tenders

We found 1102 Bid Results related to metering pumps tenders. You can find Contractor details who won metering pumps tenders along with contract details in Bid awards announcements section.

Filters
Stage
810
168
124
Tender Publishing Platform
190
912
State / UT
30
394
121
94
77
56
43
34
31
27
23
23
22
20
17
16
15
14
12
10
9
9
8
8
6
6
3
1
1
1
1
Contract Value
346
306
324
125
Publish Date
3
0
0
0
0
Sector
26
434
139
117
75
51
46
39
27
23
18
17
17
16
15
15
14
12
8
6
3
3
2
2
1
1
1
Ownership
7
720
145
125
92
18
1
1
Within keyword
Active filters:
Showing 1–23 of 1102 tenders matching your filters
2.
Agriculture #11417843 Price Bid
Tender For Nabard Ridf Xxx - Replacement Of Petty Para With Energy Efficient Pump-Sets For Dewatering Paddy Fields In Alappuzha, Kottayam And Pathanamthitta Districts Of Kerala - Supply erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams of Alappuzha, Kottayam and Pathanamthitta district with the specifications listed below:Suitable for handling saline and silty water with rpm 1000 (Syn) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel, impeller, shaft, shaft sleeve, fastener and suction pipe shall be of SS 304. Delivery pipe should be in SS 304 with minimum thickness 6 mmand of suitable length (varies from 4-10 m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starter of reputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal over load protection relay, earth fault relay, voltmeter, ammeter, fault indication start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate. Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. Screen with 6mm GI welded mesh with 50mm x 50mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation andconveyance, loading and unloading charges, charges for factory testing, but excluding GST etc. 2 Duty point head (m) : 3Minimum discharge at Duty point head (lps):266Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):15 3 Duty point head (m) : 2Minimum discharge at Duty point head (lps):532Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):20 4 Duty point head (m) : 3Minimum discharge at Duty point head (lps):354Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):20 5 Duty point head (m) : 3Minimum discharge at Duty point head (lps):443Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):25 6 Duty point head (m) :3 Minimum discharge at Duty point head (lps):532Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):30 7 Duty point head (m) :2 Minimum discharge at Duty point head (lps):1064Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):40 8 Duty point head (m) : 3Minimum discharge at Duty point head (lps):709Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):40 9 Duty point head (m) : 2Minimum discharge at Duty point head (lps):1330Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):50 10 Duty point head (m) : 3Minimum discharge at Duty point head (lps):886Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):50 11 Duty point head (m) : 2Minimum discharge at Duty point head (lps):1596Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):60 12 Duty point head (m) : 3Minimum discharge at Duty point head (lps):1064Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):60
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
3.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Contract Date: Jul 01, 2026 Contract Value : 42.75 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
7.
Defence #11337959 AOC
Bids Are invited for Tata Xenons Spare Parts Engine Overhauling Seal Kit , Kit Gasket Engine Over Hauling Gaskit , Assy Hydraulic Less Adj Wref Bs 4 , Intake Valve , D.G Ball Bearing , Set Piston Ring Std , Thrust Washer Std , Main Bearing Std , Big End Bearing Std , Sleeve Liner , Timing Belt , Diesel Return Pipe Assy , Thermostat Valve , Air Filter Element , Assy Pre Fuel Filter Delphi , Assy Fuel Filter , Belt Power Steering Pump , Belt Alternator To Pstg , Assy Sleeve Cylinder , Hydraulic Adopter , Silencer Packing , Assy Auto Tensioner , Assy Oil Pump , Oil Filter Element , Gasket Piston Cooling Jet , Water Pump Assy , Engine Mtg Both , Timing Cover Assy Bottom , Hex Fl Screw M6 X 16 Bolt , Hex Fl Bolt , H Fl Bolt , H Fl Screw , H Fl Screw , Hex Bolt , Set Clutch Assy Clutch Plate And Pressure Plate - Set Clutch Assy Clutch Plate And Pressure Plate , Assy High Pressure Pipe , H Fl Bolt , Hfl Bolt , Egr Packing , Cap Screw , H Fl Screw Sump , Self Lock Nut , Hex Screw , Assy Delivery Line Fuel Tank To Sedimeter , Assy Delivery Sedimeter To Firwl , Assy Delivery Firwl To Prmg Pump , Assy Delivery Fuel Filter To Fip , Window Winding Sw Rr Door Rh , Front Power Window Sw Pack Bs 3 By 4 , Assy Accelerator Pedal Comp , Brush Holder , Solenoid Switch Spare F002420a3 , Over Running Clutch Drive , Cam Sensor , Crank Sensor , Hose Pipe Return From Pump , Power Steering Rubber Hose Pipe , Rail Pressure Sensor , Relay With Parallel Diode , Head Light Bulb 90100W , Cam Sensor Coupler , Metering Unit Coupler Total Quantity : 131
Contract Date: Ref. Documents Contract Value : 93,929
Government Departments No of Bidders 8
8.
Agriculture #11336082 Technical Bid
Tender for Supply, Installation, Erection, Testing, And Commissioning Of Pumpsets And Allied Works At Punchavayal, Manikkuni, Kolembetta, Valiyavattam, And Padiyeripumphousesunder The Scheme Ridf Xxviii Lift Irrigation Projects In Various Padashekharams Of Wayanad District. , Supply, Installation, Erection, Testing, And Commissioning Of Pumpsets And Allied Works , 1.01 Supply, Installation, Erection, Testing, Commissioning And Fitting Charges For All Accessories Of Horizontally Mounted Submerged Centrifugal Non Clog Pump Set Of Compact Unitary Mono-Block Submerged Single/Multi Stage, Volute Type Casing With Suitable Radial Type Impellers On Common Shaft For Pump And Motor ,Anti Friction Bearing With Life Time Greasing, Protection Features With Sensors To Monitor Temperature, Mechanical Seal Leakage ,Etc.(The Pump Should Be Confirming To His/Is Standards).The Moc Of Pump, Casing-Cast Iron, Impeller -Ss Cf8m,Shaft-Ss-316,Suction Strainer -Ss And Other As Per Is Standard. The Motor Should Be Suitable For 3 Phase,415V /-10%,50Hz /- 5%,Ac Supply Submersible Motor Having Class F /H Insulation, Air Filled And Ip-68Protection Confirming To Is 325 Or Latest Standards Suitable For Day Night Operation. The Pump Discharge Capacity Of 200 Cubic Metre /Hour Against Duty Point Head Of 48 Mtrs, Working Head Range 22 - 56M, Speed 1450Rpm(N) Or Nearer ,With 10Meters Of Copper Power Cable And Control Cable, Railing Arrangement. The Pump Should Be Painted With Three Coats Of Suitable Anti Corrosive Paint Over Priming Coat. The Electrical Works For The Pumpset Should Be Completed As Per Kseb Rules And Regulations And The Contractor Is Responsible For Arranging Permissions And Certificates From The Electrical Inspectorate. The Suction Side Of The Pumpset Should Be Provided With An Additional Steel Grill For Preventing Foreign Particles Inside The Inlet Side Of The Pump Casing. - 1 Nos, 1.02 Supply And Erection Of 60Hp Auto Transformer Starter (Ats) With Suitable Incomer And Contactors Including 24 Kvar Capacitor With Required Indications ,Metering And Protections For Single Phasing ,Overload, Pump Monitoring Unit To Protect From Ingress, High Temperature Level Etc Enclosed In A Closed Panel Board - 1 Nos, 1.03 Supply And Laying Additional Termination Cable Of 1.1Kv 3.5 Core 95Sqmm Aluminium Conductor Xlpe Insulated ;Steel Armoured Ug Cable As Per Relevant Is 7098 With Support For Cable - 40 Metre, 1.04 Providing Earthing As Per The Isi Specification With Earth Electrode Of 2.10M Class Be Gi Pipe Of Dia Not Less Than 40Mm With Necessary Funnelling Arrangement With Necessary Masonry Work And 38Mm Reinforced Cement Concrete Cover Slab For Brick Masonry - 4 Each, 1.05 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. - 2462.37 Kg, Supported With Suitable Concrete Foundation. 1.06 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 250 Mm Diameter Class Ii - 1 Nos, 1.07 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 200 Mm Diameter Class Ii - 1 Nos, 1.08 Ms Pipes 200Mm - Manufacturing Supplying And Fitting 200Mm Dia Ms Pipe Of Various Length With Shell Thickness 8Mm Including Painting With 2 Coats Of Red Oxide Primer, Laying The Same To Line And Level As Directed By Departmental Officers At Site. - 30 Metre, 1.09 Ms Flanges For 200Mm Pipe - Manufacturing Supplying And Fitting 200 Mm Dia Ms Flange Having Shell Thickness 10Mm Depth 60Mm With Suitable Bolt Holes Fixing The Flange In Position With Required Welding Around The Flange Pipe Joint Grinding For Smoothing The Welded Portion, Including Painting With Red Oxide Primer Etc. Complete As Directed By Departments Officers. - 16 Joint, 1.10 Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 200 Mm Diameter Class Ii - 1 Nos, 1.11 Supplying And Fixing Pressure Gauge 0-16 Kg/Cm2 With Psi 160Mm Dia, Bottom Mounting, 1/2 Bsp, Case: Ss With Case Vent, Window: Safety Glass, Dial: White Aluminium, Pointer: Black Aluminium, Dry Case, Accuracy: 1 % Of Fs.Units/Pkg: 1 To The Delivery Line Of Pumpsets - 1 Nos, 1.12 Providing And Fixing Ms Bolts Including Nuts And Washers With Two Coats Of Priming Coat Complete . - 69 Kg, 1.13 Supplying 2 Ton Chain Pully Unit For Lifting Submersible Motor Pumpset - 1 Nos, 1.14 Supplying 20Mm Steel Rope For Lifting Pumpset - 30 Metre, 1.15 Painting With Black Anti- Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work - 102.259 Sqm, 1.16 Suitable Mobi Start Arrangement For Pumpset- 1 Nos, 1.17 Kseb Service Connection Charges To Punchavayal Pump House - 1 Nos , 2.01 Supply, Installation, Erection, Testing, Commissioning And Fitting Charges For All Accessories Of Horizontzlly Mounted Submerged Centrifugal Non Clog Pump Set Of Compact Unitary Mono-Block Submerged Single/Multi Stage, Volute Type Casing With Suitable Radial Type Impellers On Common Shaft For Pump And Motor ,Anti Friction Bearing With Life Time Greasing, Protection Features With Sensors To Monitor Temperature, Mechanical Seal Leakage ,Etc.(The Pump Should Be Confirming To His/Is Standards).The Moc Of Pump, Casing-Cast Iron, Impeller -Ss Cf8m,Shaft-Ss-316,Suction Strainer -Ss And Other As Per Is Standard. The Motor Should Be Suitable For 3 Phase,415V /-10%,50Hz /- 5%,Ac Supply Submersible Motor Having Class F /H Insulation, Air Filled And Ip-68Protection Confirming To Is 325 Or Latest Standards Suitable For Day Night Operation. The Pump Discharge Capacity Of 160 Cubic Metre /Hour Against Duty Point Head Of 40 Mtrs, Working Head Range 22 - 47M, Speed 1450 Rpm(N) Or Nearer ,With 10Meters Of Copper Power Cable And Control Cable, Railing Arrangement. The Pump Should Be Painted With Three Coats Of Suitable Anti Corrosive Paint Over Priming Coat. The Electrical Works For The Pumpset Should Be Completed As Per Kseb Rules And Regulations And The Contractor Is Responsible For Arranging Permissions And Certificates From The Electrical Inspectorate. The Suction Side Of The Pumpset Should Be Provided With An Additional Steel Grill For Preventing Foreign Particles Inside The Inlet Side Of The Pump Casing. - 1 Nos, 2.02 Supply And Erection Of 40Hp Auto Transformer Starter (Ats) With Suitable Incomer And Contactors Including 16 Kvar Capacitor With Required Indications ,Metering And Protections For Single Phasing ,Over Load, Pump Monitoring Unit To Protect From Ingress, High Temperature Level Etc Enclosed In A Closed Panel Board - 1 Nos, 2.03 Supply And Laying Additional Termination Cable Of 1.1Kv 3.5 Core 70Sqmm Aluminium Conductor Xlpe Insulated ;Steel Armoured Ug Cable As Per Relevant Is 7098 With Support For Cable - 60 Metre, 2.04 Providing Earthing As Per The Isi Specification With Earth Electrode Of 2.10M Class Be Gi Pipe Of Dia Not Less Than 40Mm With Necessary Funnelling Arrangement With Necessary Masonry Work And 38Mm Reinforced Cement Concrete Cover Slab For Brick Masonry - 4 Each, 2.05 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. - 984.95 Kg, Supported With Suitable Concrete Foundation. 2.06 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 250 Mm Diameter Class Ii - 1 Nos, 2.07 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 200 Mm Diameter Class Ii - 1 Nos, 2.08 Ms Pipes 150Mm - Manufacturing Supplying And Fitting 150Mm Dia Ms Pipe Of Various Length With Shell Thickness 6Mm Including Painting With 2 Coats Of Red Oxide Primer, Laying The Same To Line And Level As Directed By Departmental Officers At Site. - 20 Metre, 2.09 Ms Flanges For 150Mm Pipe - Manufacturing Supplying And Fitting 150Mm Dia Ms Flange Having Shell Thickness 10Mm Depth 75Mm With Suitable Bolt, Holes, Fixing The Flange In Position With Required Welding Around The Flange, Pipe Joint Grinding For Smoothing The Welded Portion Including Painting With Red Oxide Primer Etc. Complete As Directed By Departments Officers. - 16 Joint, 2.10 Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 150 Mm Diameter Class Ii - 1 Nos, 2.11 Supplying And Fixing Pressure Gauge 0-16 Kg/Cm2 With Psi 160Mm Dia, Bottom Mounting, 1/2 Bsp, Case: Ss With Case Vent, Window: Safety Glass, Dial: White Aluminium, Pointer: Black Aluminium, Dry Case, Accuracy: 1 % Of Fs.Units/Pkg: 1 To The Delivery Line Of Pumpsets - 1 Nos, 2.12 Providing And Fixing Ms Bolts Including Nuts And Washers With Two Coats Of Priming Coat Complete . - 46 Kg, 2.13 Supplying 2 Ton Chain Pully Unit For Lifting Submersible Motor Pumpset - 1 Nos, 2.14 Supplying 20Mm Steel Rope For Lifting Pumpset - 20 Metre, 2.15 Painting With Black Anti- Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work - 40.903 Sqm, 2.16 Suitable Mobi Start Arrangement For Pumpset- 1 Nos, 2.17 Kseb Service Connection Charges To Manikkuni Pump House - 1 Nos , 3.01 Supply, Installation, Erection, Testing, Commissioning And Fitting Charges For All Accessories Of Horizontally Mounted Submerged Centrifugal Non Clog Pump Set Of Compact Unitary Mono-Block Submerged Single/Multi Stage, Volute Type Casing With Suitable Radial Type Impellers On Common Shaft For Pump And Motor ,Anti Friction Bearing With Life Time Greasing, Protection Features With Sensors To Monitor Temperature, Mechanical Seal Leakage ,Etc.(The Pump Should Be Confirming To His/Is Standards).The Moc Of Pump, Casing-Cast Iron, Impeller -Ss Cf8m,Shaft-Ss-316,Suction Strainer -Ss And Other As Per Is Standard. The Motor Should Be Suitable For 3 Phase,415V /-10%,50Hz /- 5%,Ac Supply Submersible Motor Having Class9;F39;/H Insulation, Air Filled And Ip-68Protection Confirming To Is 325 Or Latest Standards Suitable For Day Night Operation. The Pump Discharge Capacity Of 185 Cubic Metre /Hour Against Duty Point Head Of 24 Mtrs, Working Head Range 18 - 34M, Speed 1450Rpm(N) Or Nearer ,With 10Meters Of Copper Power Cable And Control Cable, Railing Arrangement. The Pump Should Be Painted With Three Coats Of Suitable Anti Corrosive Paint Over Priming Coat. The Electrical Works For The Pumpset Should Be Completed As Per Kseb Rules And Regulations And The Contractor Is Responsible For Arranging Permissions And Certificates From The Electrical Inspectorate. The Suction Side Of The Pumpset Should Be Provided With An Additional Steel Grill For Preventing Foreign Particles Inside The Inlet Side Of The Pump Casing. - 1 Nos, 3.02 Supply And Erection Of 30Hp Auto Transformer Starter (Ats) With Suitable Incomer And Contactors Including 12.5 Kva Capacitor With Required Indications ,Metering And Protections For Single Phasing ,Over Load, Pump Monitoring Unit To Protect From Ingress, High Temperature Level Etc Enclosed In A Closed Panel Board - 1 Nos, 3.03 Supply And Laying Additional Termination Cable Of 1.1Kv 3.5 Core 50Sqmm Aluminium Conductor Xlpe Insulated ;Steel Armoured Ug Cable As Per Relevant Is 7098 With Support For Cable - 40 Metre, 3.04 Providing Earthing As Per The Isi Specification With Earth Electrode Of 2.10M Class Be Gi Pipe Of Dia Not Less Than 40Mm With Necessary Funnelling Arrangement With Necessary Masonry Work And 38Mm Reinforced Cement Concrete Cover Slab For Brick Masonry - 4 Each, 3.05 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. - 2462.37 Kg, Supported With Suitable Concrete Foundation. 3.06 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 150 Mm Diameter Class Ii - 1 Nos, 3.07 Ms Pipes 150Mm - Manufacturing Supplying And Fitting 150Mm Dia Ms Pipe Of Various Length With Shell Thickness 6Mm Including Painting With 2 Coats Of Red Oxide Primer, Laying The Same To Line And Level As Directed By Departmental Officers At Site. - 35 Metre, 1.26 Ms Flanges For 150Mm Pipe - Manufacturing Supplying And Fitting 150Mm Dia Ms Flange Having Shell Thickness 10Mm Depth 75Mm With Suitable Bolt, Holes, Fixing The Flange In Position With Required Welding Around The Flange, Pipe Joint Grinding For Smoothing The Welded Portion Including Painting With Red Oxide Primer Etc. Complete As Directed By Departments Officers. - 18 Joint, 1.29 Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 150 Mm Diameter Class Ii - 1 Nos, 3.08 Supplying And Fixing Pressure Gauge 0-16 Kg/Cm2 With Psi 160Mm Dia, Bottom Mounting, 1/2 Bsp, Case: Ss With Case Vent, Window: Safety Glass, Dial: White Aluminium, Pointer: Black Aluminium, Dry Case, Accuracy: 1 % Of Fs.Units/Pkg: 1 To The Delivery Line Of Pumpsets - 1 Nos, 3.09 Providing And Fixing Ms Bolts Including Nuts And Washers With Two Coats Of Priming Coat Complete . - 34 Kg, 3.10 Supplying 2 Ton Chain Pully Unit For Lifting Submersible Motor Pumpset - 1 Nos, 3.11 Supplying 20Mm Steel Rope For Lifting Pumpset - 30 Metre, 3.12 Painting With Black Anti- Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work - 102.258 Sqm, 3.13 Suitable Mobi Start Arrangement For Pumpset- 1 Nos, 3.14 Kseb Service Connection Charges To Kolembetta Pump House - 1 Nos , 4.01 Supply, Installation, Erection, Testing, Commissioning And Fitting Charges For All Accessories Of Horizontally Mounted Submerged Centrifugal Non Clog Pump Set Of Compact Unitary Mono-Block Submerged Single/Multi Stage, Volute Type Casing With Suitable Radial Type Impellers On Common Shaft For Pump And Motor ,Anti Friction Bearing With Life Time Greasing, Protection Features With Sensors To Monitor Temperature, Mechanical Seal Leakage ,Etc.(The Pump Should Be Confirming To His/Is Standards).The Moc Of Pump, Casing-Cast Iron, Impeller -Ss Cf8m,Shaft-Ss-316,Suction Strainer -Ss And Other As Per Is Standard. The Motor Should Be Suitable For 3 Phase,415V /-10%,50Hz /- 5%,Ac Supply Submersible Motor Having Class F /H Insulation, Air Filled And Ip-68Protection Confirming To Is 325 Or Latest Standards Suitable For Day Night Operation. The Pump Discharge Capacity Of 155 Cubic Metre /Hour Against Duty Point Head Of 22 Mtrs, Working Head Range 13 - 27M, Speed 1450 Rpm(N) Or Nearer, With 10Meters Of Copper Power Cable And Control Cable, Railing Arrangement. The Pump Should Be Painted With Three Coats Of Suitable Anti Corrosive Paint Over Priming Coat. The Electrical Works For The Pumpset Should Be Completed As Per Kseb Rules And Regulations And The Contractor Is Responsible For Arranging Permissions And Certificates From The Electrical Inspectorate. The Suction Side Of The Pumpset Should Be Provided With An Additional Steel Grill For Preventing Foreign Particles Inside The Inlet Side Of The Pump Casing. - 1 Nos, 4.02 Supply And Erection Of 25Hp Auto Transformer Starter (Ats) With Suitable Incomer And Contactors Including 10 Kvar Capacitor With Required Indications ,Metering And Protections For Single Phasing ,Over Load, Pump Monitoring Unit To Protect From Ingress, High Temperature Level Etc Enclosed In A Closed Panel Board - 1 Nos, 4.03 Supply And Laying Additional Termination Cable Of 1.1Kv 3.5 Core 35Sqmm Aluminium Conductor Xlpe Insulated ;Steel Armoured Ug Cable As Per Relevant Is 7098 With Support For Cable - 20 Metre, 4.04 Providing Earthing As Per The Isi Specification With Earth Electrode Of 2.10M Class Be Gi Pipe Of Dia Not Less Than 40Mm With Necessary Funnelling Arrangement With Necessary Masonry Work And 38Mm Reinforced Cement Concrete Cover Slab For Brick Masonry - 4 Each, 4.05 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. - 344.73 Kg, Supported With Suitable Concrete Foundation. 4.06 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 150 Mm Diameter Class Ii - 1 Nos, 4.07 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 125 Mm Diameter Class Ii - 1 Nos, 4.08 Ms Pipes 125Mm - Manufacturing Supplying And Fitting 125Mm Dia Ms Pipe Of Various Length With Shell Thickness 6Mm Including Painting With 2 Coats Of Red Oxide Primer, Laying The Same To Line And Level As Directed By Departmental Officers At Site - 15 Metre, 4.09 Ms Flanges For 125Mm Pipe - Manufacturing Supplying And Fitting 125 Mm Dia Ms Flange Having Shell Thickness 10Mm Depth 60Mm With Suitable Bolt Holes Fixing The Flange In Position With Required Welding Around The Flange Pipe Joint Grinding For Smoothing The Welded Portion, Including Painting With Red Oxide Primer Etc. Complete As Directed By Departments Officers. - 16 Joint, 4.10 Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 125 Mm Diameter Class Ii - 1 Nos, 4.11 Supplying And Fixing Pressure Gauge 0-16 Kg/Cm2 With Psi 160Mm Dia, Bottom Mounting, 1/2 Bsp, Case: Ss With Case Vent, Window: Safety Glass, Dial: White Aluminium, Pointer: Black Aluminium, Dry Case, Accuracy: 1 % Of Fs.Units/Pkg: 1 To The Delivery Line Of Pumpsets - 1 Nos, 4.12 Providing And Fixing Ms Bolts Including Nuts And Washers With Two Coats Of Priming Coat Complete . - 29 Kg, 4.13 Supplying 2 Ton Chain Pully Unit For Lifting Submersible Motor Pumpset - 1 Nos, 4.14 Supplying 20Mm Steel Rope For Lifting Pumpset - 10 Metre, 4.15 Painting With Black Anti- Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work - 14.316 Sqm, 4.16 Suitable Mobi Start Arrangement For Pumpset- 1 Nos, 4.17 Kseb Service Connection Charges To Valiyavattam Pump House - 1 Nos , 5.01 Supply, Installation, Erection, Testing, Commissioning And Fitting Charges For All Accessories Of Horizontally Mounted Submerged Centrifugal Non Clog Pump Set Of Compact Unitary Mono-Block Submerged Single/Multi Stage, Volute Type Casing With Suitable Radial Type Impellers On Common Shaft For Pump And Motor ,Anti Friction Bearing With Life Time Greasing, Protection Features With Sensors To Monitor Temperature, Mechanical Seal Leakage ,Etc.(The Pump Should Be Confirming To His/Is Standards).The Moc Of Pump, Casing-Cast Iron, Impeller -Ss Cf8m,Shaft-Ss-316,Suction Strainer -Ss And Other As Per Is Standard. The Motor Should Be Suitable For 3 Phase,415V /-10%,50Hz /- 5%,Ac Supply Submersible Motor Having Class F /H Insulation, Air Filled And Ip-68Protection Confirming To Is 325 Or Latest Standards Suitable For Day Night Operation. The Pump Discharge Capacity Of 125 Cubic Metre /Hour Against Duty Point Head Of 26 Mtrs, Working Head Range 16 - 32M, Speed 1450 Rpm(N) Or Nearer ,With 10Meters Of Copper Power Cable And Control Cable, Railing Arrangement. The Pump Should Be Painted With Three Coats Of Suitable Anti Corrosive Paint Over Priming Coat. The Electrical Works For The Pumpset Should Be Completed As Per Kseb Rules And Regulations And The Contractor Is Responsible For Arranging Permissions And Certificates From The Electrical Inspectorate. The Suction Side Of The Pumpset Should Be Provided With An Additional Steel Grill For Preventing Foreign Particles Inside The Inlet Side Of The Pump Casing. - 1 Nos, 5.02 Supply And Erection Of 20Hp Auto Transformer Starter (Ats) With Suitable Incomer And Contactors Including 8 Kvar Capacitor With Required Indications ,Metering And Protections For Single Phasing ,Over Load, Pump Monitoring Unit To Protect From Ingress, High Temperature Level Etc Enclosed In A Closed Panel Board - 1 Nos, 5.03 Supply And Laying Additional Termination Cable Of 1.1Kv 3.5 Core 35 Sqmm Aluminium Conductor Xlpe Insulated ;Steel Armoured Ug Cable As Per Relevant Is 7098 With Support For Cable - 50 Metre, 5.04 Providing Earthing As Per The Isi Specification With Earth Electrode Of 2.10M Class Be Gi Pipe Of Dia Not Less Than 40Mm With Necessary Funnelling Arrangement With Necessary Masonry Work And 38Mm Reinforced Cement Concrete Cover Slab For Brick Masonry - 4 Each, 5.05 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. - 344.73 Kg, Supported With Suitable Concrete Foundation. 5.06 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 200 Mm Diameter Class Ii - 1 Nos, 5.07 Providing And Fixing C.I. Non Return Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 125 Mm Diameter Class Ii - 1 Nos, 5.08 Ms Pipes 125Mm - Manufacturing Supplying And Fitting 125Mm Dia Ms Pipe Of Various Length With Shell Thickness 6Mm Including Painting With 2 Coats Of Red Oxide Primer, Laying The Same To Line And Level As Directed By Departmental Officers At Site - 15 Metre, 5.09 Ms Flanges For 125Mm Pipe - Manufacturing Supplying And Fitting 125 Mm Dia Ms Flange Having Shell Thickness 10Mm Depth 60Mm With Suitable Bolt Holes Fixing The Flange In Position With Required Welding Around The Flange Pipe Joint Grinding For Smoothing The Welded Portion, Including Painting With Red Oxide Primer Etc. Complete As Directed By Departments Officers. - 18 Joint, 5.10 Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertion Etc. (The Tail Pieces If Required Will Be Paid Separately): 125 Mm Diameter Class Ii - 1 Nos, 5.11 Supplying And Fixing Pressure Gauge 0-16 Kg/Cm2 With Psi 160Mm Dia, Bottom Mounting, 1/2 Bsp, Case: Ss With Case Vent, Window: Safety Glass, Dial: White Aluminium, Pointer: Black Aluminium, Dry Case, Accuracy: 1 % Of Fs.Units/Pkg: 1 To The Delivery Line Of Pumpsets - 1 Nos, 5.12 Providing And Fixing Ms Bolts Including Nuts And Washers With Two Coats Of Priming Coat Complete . - 23 Kg, 5.13 Supplying 2 Ton Chain Pully Unit For Lifting Submersible Motor Pumpset - 1 Nos, 5.14 Supplying 20Mm Steel Rope For Lifting Pumpset - 10 Metre, 5.15 Painting With Black Anti- Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work - 14.316 Sqm, 5.16 Suitable Mobi Start Arrangement For Pumpset- 1 Nos, 5.17 Kseb Service Connection Charges To Padiyeri Pump House - 1 Nos
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
9.
Railways #11331549 AOC
Supply Of metering pump
Contract Date: Jun 23, 2026 Contract Value : 4.95 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
11.
Heavy Industries and Public Enterprises #11298122 Technical Bid
Tender for Gear Pump Reservoir Part No.: Mfe5-Kw3 S400+29E Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-10000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-60000-00, Make: Skf , Drg: - Rev: Piston Distributor Part No.: 341-400-20000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-30000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-40000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-50000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 351-000-50000-00, Make: Skf , Monoflex Distributor, 342-400-55000-Zz , Drg: - Rev: Gear Pump Reservoir, Part No.: Mfe5-2000+299, Make: Skf N.Std:- , Drg: -- Rev: Piston Type Distributor, Part No.: 343-455-500, Make: Skf , Drg: -- Rev: Piston Type Distributor, Part No.: 345-400-55555-Zz, Make: S Kf , Drg: -- Rev: Adjust. Valve, Part No.: Wvn20 0-10E35, Make: Skf , Drg: -- Rev: Adjust. Valve, Part No.: Wvn20 0-10E60, Make: Skf , Drg: -- Rev: Oil+Air Meter. Unit, Part No.: Mv203-100-11100000, Make: Skf , Drg: -- Rev: Gear Pump Unit, Part No.: Mfe5 -3041+29E, Make: Skf , Metering Unit, Part No.: 320-406-3, Make: Skf , Drg: -- Rev: Helical Coil, Part No.: 828-09 0-004, Make: Skf , Drg: -- Rev: Vane Pump Voltage Range Ii, Pa Rt No.: Flmf12-2007-299, Make: Skf , Drg: -- Rev: Piston Type Distributor, Part No.: 342-400-33000-Zz, Make: S Kf , Drg: -- Rev: Vane Pump, Part No.: Flm12-300 0+29E, Make: Skf , Drg: -- Rev: Pump Element With O Ring Kfa1.U3 , Drg: -- Rev: Pressure Regulating Valve 161-210-041 , Drg: - Rev: Tube Fixer Pnz-12, Part No-226-12508-5 , Gear Pump Reservoir Part No.: Mfe5-Kw3 S400+29E Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-10000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-60000-00, Make: Skf , Drg: - Rev: Piston Distributor Part No.: 341-400-20000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-30000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-40000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 341-400-50000-00, Make: Skf , Drg: - Rev: Piston Distributor, Part No.: 351-000-50000-00, Make: Skf , Monoflex Distributor, 342-400-55000-Zz , Drg: - Rev: Gear Pump Reservoir, Part No.: Mfe5-2000+299, Make: Skf N.Std:- , Drg: -- Rev: Piston Type Distributor, Part No.: 343-455-500, Make: Skf , Drg: -- Rev: Piston Type Distributor, Part No.: 345-400-55555-Zz, Make: S Kf , Drg: -- Rev: Adjust. Valve, Part No.: Wvn20 0-10E35, Make: Skf , Drg: -- Rev: Adjust. Valve, Part No.: Wvn20 0-10E60, Make: Skf , Drg: -- Rev: Oil+Air Meter. Unit, Part No.: Mv203-100-11100000, Make: Skf , Drg: -- Rev: Gear Pump Unit, Part No.: Mfe5 -3041+29E, Make: Skf , Metering Unit, Part No.: 320-406-3, Make: Skf , Drg: -- Rev: Helical Coil, Part No.: 828-09 0-004, Make: Skf , Drg: -- Rev: Vane Pump Voltage Range Ii, Pa Rt No.: Flmf12-2007-299, Make: Skf , Drg: -- Rev: Piston Type Distributor, Part No.: 342-400-33000-Zz, Make: S Kf , Drg: -- Rev: Vane Pump, Part No.: Flm12-300 0+29E, Make: Skf , Drg: -- Rev: Pump Element With O Ring Kfa1.U3 , Drg: -- Rev: Pressure Regulating Valve 161-210-041 , Drg: - Rev: Tube Fixer Pnz-12, Part No-226-12508-5
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Uttarakhand View Result →
12.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
13.
Power #11267487 Technical Bid
Tender for Rate Contract For Procurement Of Material In Respect Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized , Procurement Of Material In Respect Of Std Ganderbal For The Year 2025-26 Or Till Next Stage Contract Is Finalized , 11 Kv Horn Gap Fuse Set 3 Phase 200A , 11Kv Link Rods For 11Kv Link Set 22 Feet Long With Insulating Bottom Grip Bamboo/Carbon Fibre , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 11 Kv Isolator, Double Break,3-Pole, 600Amp, Horizontal Mounting Type, With Earth Switch Complete Including Clamps And Fittings , 11 Kv 3-Core Current Transformer 800-400/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 750-375/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 600-300/5-5 A, ( Metering, Protection, Differential Core) , 11 Kv 2-Core Current Transformer 600-300/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 400-200/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 100-50/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 50-25/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 20-10/5-5 A, ( Metering, Protection) , 11 Kv Potential Transformer 110V, Accuracy Class 0.5 , Tension Fittings For 0.1 Acsr Conductor 70Kn , Tension Fittings For 0.15 Acsr Conductor 70 Kn , Tension Fittings For 0.2 Acsr Conductor 120 Kn , 185 Sqmm, 3Core , 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 3 Core ,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core, 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 240 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 120 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 120 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 11 Kv 630 Mm² Single Core Xlpe Cable Armoured, Frls (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , Tripping And Closing Coils Must Have Burden Between 250 To 350 Watts At 30V Dc With Housing , Tripping Coil Of 11Kv Alind Make Vcb , Tripping Coil Of 11 Kv Er/Vijai Make Vcb , Tripping Coil Of 11Kv Electric Field Make Vcb , Tripping Coil Of 11Kv Abb Make Vcb , Tripping Coil Of 11Kv Crompton Make Vcb , Tripping Coil Of 11Kv Stelmac Make Vcb , Tripping Coil Of 11Kv Sudhir/Schneider Make Vcb , Tripping Coil Of 11Kv Pascal Make Vcb , Closing Coil Of 11Kv Alind Make Vcb , Closing Coil Of 11 Kv Er/Vijai Make Vcb , Closing Coil Of 11Kv Electric Field Make Vcb , Closing Coil Of 11Kv Abb Make Vcb , Closing Coil Of 11Kv Crompton Make Vcb , Closing Coil Of 11Kv Stelmac Make Vcb , Closing Coil Of 11Kv Sudhir/Schneider Make Vcb , Closing Coil Of 11Kv Pascal Make Vcb , 33 Kv Link Set Heavy Duty- Post Type, 800A Complete , 33Kv Link Rods Fibre/Bamboo Oil Impregnated With Insulated Bottom Grip 30 Feet Long , 33Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm. , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type A , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type B For 0.2 Acsr Conductor , 30 Kv Lightening Arrestor Set, 10 Ka, Station Class, Zno, Polymer Gap Less (Set Consists Of 03 No.) With All Accessories Required For Installation. , 33 Kv Isolator Without Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Isolator With Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Current Transformer (33 Kv, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. Per Φ) 3-Core, 0.5 5P10, Ps-Class 3 Core- With All Accessories Required For Installation , 400-200/5-5 A (Metering, Protection And Differential Core ) , 250-125/5-5 A (Metering, Protection And Differential Core ) , 33 Kv Voltage Transformer (33 Kv/110 V, 1Φ, Multi-Core, Outdoor), (1No. Per Φ) With All Accessories Required For Installation , Tripping Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb) , Closing Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb, Stelmac Etc ) , 33 Kv Polymer Post Insulator 36Kv,170Kv Impulse, Creepage Distance 1224M , Earthing Complete (Spike Earthing Rod 20Mm,2.5 Mtr Long) , Galvanised Earthing Strips 50X6 Mm/ 25X3mm , Galvanised Nuts & Bolts Of Different Sizes And Sorts , Pg Clamps For 0.1 Acsr Conductor 400A Pressure Di-Cast , Pg Clamps For 0.15 Acsr Conductor 500A Pressure Di-Cast , Pg Clamps For 0.2 Acsr Conductor 630A Pressure Di-Cast , Prefabricated Galvanised Channel Iron/ Angle Iron Of Different Sorts As Required , Prefabricated Galvanised Flat Iron Of Sorts 50/25 8/6Mm Thick , Instrument, Tools And Other Equipments , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick With Sliding Mechanism , Bamboo Ladder 25 Long , 12V/7Ah Led Handheld Searchlight (Andslite/Philipls/Microtech,Fos) , Tool Kit Of Suitable Size With Tools ( Stanley / Taparia/Jon/Jk/ Make) Comprising Of :- Double End Spanners With Increases Or Decreased Sized Ends And D/Ring Type Following Sizes And Numbers Spanners 6-0, 7-8, 9-9-10, 10-11, 11-12, 12-13, 14-15, 16-17, 18-19, 20-21, 20-22, 24-27, 25-28, 30-32, Complete Set Cushion Grip, Pipe Wrench 12 Inch 1 No. 24 Inch 1 No., 12 Adjustable Chrome Plated Wrench, 8 Combination Plier Line Man Plier, 8 Long Nose Plier Length Nose Plier, 9 Crimping Plier Set, 230Mm-, 7 Length Cutting Plier, Hex Key(Ln Key) Set 11Pc Metric (1.5, 2, 2.5, 3, 4, 5,5.5, 6, 8, 10Mm 12Mm), 27Pc-1/2 Sq. Dr 12Pt Socket Set ( Comprising Of ) 20 Pc :- 1/2 Drive 12 Point Sockets: 10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,30,32Mm 6 Pc :- 1/2 Drive Accessories : 2 Pc Extension Bar: 5 And 10(125 And 250Mm) Universal Joint, 1 Pc :- Spark Plug Socket 6 Point 13/16, 1 Pc Sliding T-Bar 10(254Mm); 1 Pc Flip-Drive Rachet., 1/4 Torque Rench, 914Mm , 36 Inch Bolt Cutter (Taparia Make, 12 Hacksaw Frame With 12 No. Spare Blades, Steel Body Retactable Utility Knife With 12 No. Spare Knives, 12H 340Gms Ball Pien Hammer Wooden Handle, 16 900Gms Ball Pien Hammer Wooden Handle, 5 Mtr Measuring Tape, Cold Chesel 7/8 (22Mm), Centre Punch 8Mm (15/16 )X 115Mm(4 1/2 ), Good Quality Multi Meter ( Fluke, Motwane, Meggar Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. 24 Magnetic Torpedo/ Beam Level (3Vails) 300Mm -1 No. & 600Mm -1No., Files Flat/Round Type 8-12 Inch Long, Srew Driver Set Comprising Of 12 No.S Long Shank Having Star/Flat Type Tips With Heavy Duty Tefon Grips , Hv Detectors For All Voltages. (With Fiber Rod Telescopic) , Pliers (Make-Taparia/Stanley) , 11 Kv Hand Gloves ( Make 3M/ Crystal) , Earth Resistivity Tester (0-1000 Ohms) (Make-Motwane/Megger/ Fluke/Markoni) With Auto-Manual Options , Digital Insulation Resistance Tester 5000V (Make-Sonel/Megger/ Fluke/Equivalent) , 10 Feet A Type Ladder , Portable Welding Set , Portable Blue Lamp(Gas) , Portable Blue Lamp (Kerosene) , Insulation Tester And Continuity Tester 2.5 Kv Withvarious Kits (Make- Fluke/ Megger/Equivalent) , Clamp Meter/ Multi Meter ( Fluke, Motwane, Meggar/Meeca Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. , Heavy Duty Pulling & Lifting Machine 5 Mt , Control Relays With 3Oc+1Ef 2 Element Based Digital Of Following Make. , Mit- 114/104 (Er) Make. , Lnt M314a , Schneider , Simens 7Sr , Crompton 14C , Crompton 14Cn , Ashida 131A , Ashida 141 A/B , Ashida Adr241a , Ashida Adr242b , Abb Ref 615 , High Speed Master Relay With 12-63Vdc, 12-220 Vac Coil And 4 No+4Nc Driver Contacts , Battery Bank 30 V,100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type,High Impact Polyprophelene Copolymer Container,Flame Retardant (Exide/Amaron/Shoto/Hbl Make) , Battery Bank 36 V, 150 Ah Ultra Low Maintenance Tubular Battery Bank Compromising Of 3 No. Batteries Each Of 12 Volt (Hbl/Exide/Amaron/Luminous) , Battery Charger 36V, 40/60A With Full Wave Power Diode/Scr Based Recetification And Ripple Filtration. Avr Based Semi Digital With Inbuilt Autotransformer/Variant And Auto Manual Mode Having Digtal Precision Type/ Measuring Instruments, Led Type Indication, Inbuilt Buzzer/ Hoter Alarm During Technical Snags. The Charger Operating Ranges Must Be From 110V To 260 Vac Input Without Attoring Dc Output Through Smps , 7.5 Kva Servo Stablizer Copper Wound With Input Voltage Range 90V To 260V , Distilled Water For Batteries , Power Diodes P-Type/ N-Type ( 40 To 100 A) With Heat Shink , Charger Coil 240/36V Ac , Avr Card Compatile With Existing Chargers , Dc Volt Meter ( 0-60V) , Dimmer/Variac 110V To 260Vac , Power Transformer Equipments , Winding Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes Lv (Make-(Emco/Yoca/Excel) , Oil Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes (Make-(Emco/Yoca/Excel) , Power Oil Conforming To Is:335 Standards , 33 Kv Bushing For 10 Mva Power Transformer , 33 Kv Bushing For 6.3 Mva Power Transformer , 33 Kv Bushing For 5/4/3.15 Mva Power Transformer , 33 Kv Bush Rods For 10 Mva Power Transformer , 33 Kv Bush Rods For 6.3 Mva Power Transformer , 33 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11 Kv Bushing For 10 Mva Power Transformer , 11 Kv Bushing For 6.3 Mva Power Transformer , 11 Kv Bushing For 5/4/3.15 Mva Power Transformer , 11 Kv Bush Rods For 10 Mva Power Transformer , 11 Kv Bush Rods For 6.3 Mva Power Transformer , 11 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11Kv Outdoor Breaker Bushing , Oil Sealing For 33/11Kv Bushing Suitable For 1.0/3.15/2.5/6.3/10Mva , Miscellanous Items , Aluminum Thimble 120 Sqmm 3Mm Thick , Aluminum Thimble 185 Sqmm 3Mm Thick , Aluminum Thimble 240 Sqmm 3Mm Thick , Aluminum Thimble 300 Sqmm 3Mm Thick , Aluminum Thimble 400 Sqmm 3Mm Thick , Aluminum Thimble 630 Sqmm 4Mm Thick , Flexible Insulated Copper Bus/ Braid , Copper Bus Bars 12 Mm Thick , Aluminum Bus Bars 12 Mm Thick , T-Clamps For 0.1 Acsr 400A Presure Di-Cast , T-Clamps For 0.15 Acsr 500A Presure Di-Cast , T-Clamps For 0.20 Acsr 630A Presure Di-Cast , Isolator Pad Clamps 630A Presure Di-Cast , Single Phase Water Pump Motor, Power: 1 Hp , Led Lamp 15 Watt, B-22 Type (Make-Syska/Havells/Wipro/Surya/Ce/Gm) , 50 Watt Led Street Light With Fitting Complete (Make-Syska/Havells/Wipro/Surya/Ce/Gm) Ip-67 , Automatic Voltage Stablizer 5 Kva Copper Wound , 1.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 2.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 4 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 16 annual periodical maintenance Top (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Switch (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Socket (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Combine (Socket/Switch) (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Extension Board With 5 Socket With Fuse And Switch (Make-Anchor/Havells/Crompton/Equivalent) , Pvc Flexible Pipe 1/2 Dia , Ppr Pipe 0.75 Dia , Ppr Pipe 0.5 Dia , Poly Propline Rope-20-30 Mm , Motorized Wood Cutter (58Cc 3.5Hpchain Saw With 22 Inch Cutter Bar Power Full Engine) , Pt Clamps , 33Kv La Clamps 6Mm Thick , Pad Clamps (Aluminuim /Bi Metalic 600A)Presure Di-Cost , Baby Insulators With Nuts & Bolts , 33Kv Ct Clamps ( Threaded And Band Type Cu Made) Tin Coated , Crimping Tool Xple Cable ( Hydraulic Type Upto 120 Sqmm To 630 Sqmm) , Korean Mink Blanket 220X240 Cm 4Kg Weight.Rate Be Quoted Per Kg , Pvc Insulated Copper Bus Bar (50 Mm X 12 Mm) Including Nuts And Bolts 1250A , 11 Kv Vacuum Interrupters (800A/600A) Suitable For Vijai, Er, S&S, Alind, Crompton, Electric Field, Abb, Stelmac, Pascal. Indoor/Outdoor Breakers. , 11 Kv Vacuum Interrupters (800A/600A) Suitable For L&T, Schneider, Sudhir Etc. , 11 Kv Vacuum Interrupters Housing Of Below Mentioned Make. , Vijai And Easun Reyrolle (Per Phase) , Alind (Assembly Upper Set/ Lower Set). , Abb/Electric Field/Crompton/S&S ( Per Phase) , Sudhir And Schneider (Per Phase) , Outdoor Type Pcvcb Upper And Lower Part(Per Phase) , 11 Kv Vcb Equipments Below (Make-Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Voltmeter 11Kv/110V , Ampere Meter , Selector Switch- 16 Amps Vss/Ass , Led Panel Indicators , Push Button With 2No+2Nc , Master Tripping Relay With 4No+4Nc , Hrc Fuse With Base -16 Amps , Connecting Ribs , Auxilary Switch With 8No+8Nc Complete With Bracket And Lever , Auxilary Switch With 12No+12Nc Complete With Bracket Lever , Auxilary Relay -30 A , Trip Circuit Supervision Relay , Bell/Buzzer , Arching Chamber , Tripping Mechanism , Re-Setting Links , Operating Shaft , Shower Contact , Isolating Sockets , Brass Chamber , Lifting Rods , Rollers , Closing Shaft , Contact Bar , Aluminum Chamber , Spring Tension Rod , Gear Assembly , Bmr Mechanism Complete , 33 Kv C&R Panel Equipments (Make Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Bucholz Relay , Winding Temperature Relay , Oil Temperature Relay , Tripping Relay , Alarm Relay , Master Tripping Relay With 4No+4Nc , Tnc Switch 25 Amp. , Energy Meter Of Secure Make With Latest Series Premier 500 Of 11Kv Level And 33Kv Level With 5A Secondary. 11Kv/110V-5A / 33Kv/110V-5A , Electronic Hooter , Ampere Meter With Selector Switch , Voltmeter With Selector Switch , Hrc Fuse With Base , Bell/Buzzer , 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls , 12 Core . , 8 Core , 6 Core , 4 Core , 2 Core , 33 Kv Vcb Equipments (Make : Electricfield/Crompton/Abb/Bhel/Sudhir/Pascal/Beeco Lawrie/Megawin) , 33 Kv Vacuum Interrupter 1250A , 33 Kv Porcelain Post Insulator (Msli 1200+) , Operating Rods , Tripping/Closing Coils , Motor Charging 240, 1Cb, 0.1 Kv , Gasket , Operating Shaft , Mechanism Housing , Gear Assembly , Vacuum/Gas Charging Valve , Input/Output Housing Terminal Pads Din Pail Mounted Type , Xlpe Lt Cable 3.5 Core, Armoured, Fire Resistant Of Sizes , 95 Sq.Mm , 120 Sq.Mm , 185 Sq.Mm , 240 Sq.Mm , 300 Sq.Mm , 400 Sq.Mm , 2Mva/1Mva/630Kva/400Kva/250Kva/100Kva ,33/0.433 Kv, 3-Phase Distribution Transformers Eqiments: , 1600 annual periodical maintenance 4P Acb Drawal Type , Breaking Capacity 50Ka With Enclosure , Mccb ‐ 630 Amps , 36 Ka, 4P With Box Ics=100% Icu At 415 (Ka Rms) , Mccb ‐ 400 Amps , 36 Ka, 4P With Box , Mccb ‐ 250 Amps , 36 Ka, 4P With Box , Mccb ‐ 160 Amps , 36 Ka, 4P With Box , Mccb ‐ 1200 Amps , 36 Ka, 4P With Box , 120 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 240 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 400 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 630 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 33/0.433 Kv Transformer Lv Bushing Suitable For 100Kva To 2 Mva: , 33/0.433 Kv Transformer Lv Bush Rods Suitable For 100Kva To 2 Mva: , Safety Equipments , Safety Helmets Make-3M/Akamgo/ Hilson) , 33Kv Hand Gloves (3M/Crystal/Honeywell/Meeco/Jyot) , Safety Shoes Valcanised Rubber Made (Make-Allen/ Hillson/ Gasoline/Liberty/Acme/Bata/Neosafe/Honetwell) , Safety Belts Shock Absorber Type (Make-3M/Neo) , Safety Glasses (Make-Stanley/ 3M / Allen) , Safety Jackets (Make-Allen/ Hillson/ Gasoline) , Rain Protective Suit Complete- Pant And Jacket Ip-67 Protected , Fire Extingiusher Co₂ Type Of 6.5 Kg Capacity For Control Room , Fire Extingiusher Abc/Dpc Type Of 9 Kg Capacity For Control Room , Refilling Of Empty/Expred Fireextinguishers , Rubber Mat 1Mx2m 19Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
15.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
18.
Power #11206303 Price Bid
Tender for Contract For Supply Of Key Materials Required For Maintenance Of 33/11Kv Receiving Stations Along With Their Lines Under The Jurisdiction Of Std Bijbehara During The Year 2026-27 , Electrical Store/Workshop Items/: As Per Is Standards , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Incommer) As Per Technical Specifications Of Rec Std , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Outgoing) As Per Technical Specifications Of Rec Std , 33 Kv Vcb (36 Kv, 1250A, 26.2 Ka, Outdoor Type) As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Out Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv Isolator With Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Isolator Without Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Outdoor, Oil Cooled, Live Tank, Single Phase , 3 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection,0.5 For Metering & Ps For Differential With Ratio 800-400/5-5-5A ,600-300/5-5-5A , 500-250/5-5-5A, 400-200/5-5-5A (Per Set Of 3 Pieces) , 33 Kv Outdoor, Oil Cooled, Copper Wound , Single Phase , Pt Set With Rated Primary Voltage 33000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 (Per Set Of 3 Pieces). , 33 Kv Lightening Arrestors (30 Kv, 10Ka, Station Class, Zno, Porcelain/Polymer) Gap Less(Per Set Of 3 Pieces). , 33 Kv Post Insulator (Polymer/Porcelain 36Kv, 170Kv Impulse) , Galvanised Steel Structures(6 G I Pipe With Top,Base & Grouting Bolts) As Per Rec , 11Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 2.5 Sqmm 2 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 4 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 6 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 8 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , L T Cable 3 1/2 16 Sq.Mm Core Armored , Al Conductor Sheathed Pvc Insulated (Std Make) , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Or Raychem Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 120Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 120Qmm , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 11 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb, Electric Field, Sudhir Or The Like , 11 Kv Indoor Type,Dry,Resin Cast, Single Phase , 2 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection & 0.5 For Metering Preferably Of Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make Having) With Ratio 800-400/5/5,600-300/5-5,400-200/5-5 (Per Set Of 3 Pieces). , 11 Kv Indoor ,Dry, Copper Wound , Three Phase , Pt Set In Ms Enclosure With Rated Primary Voltage 11000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 , 11 Kv Lightening Arrestor Set( Station Type),Outdoor, Metal Oxide Gapless As Per Isi Specifications.(Per Set Of 3 Pieces). , Digital Protection Relay Non-Communicable Model Type 141A (Ashida/Er Make) 3 O/C +1 E/F For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make . Auxillary Voltage 30V Ac/Dc Confirming To Iso 9001:2008 Standards. , Master Trip Relay 24-50V For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make. , 36V , 200Ah Battery Bank (Comprising Of 3 No Batteries Of 12 V Each) Conforming To Iec60896-21/22, Lead Acid Type Of Exide Make , 36 V,200 Ah , Float-Cum-Boost Battery Charger,Copper Wound,Air Cooled, With Full Wave Rectification With Heat Sink & 40A Diodes, Ae Make Measuring Instruments, 16Swg Steel Body Sheet, For 15A,220 V, 1Phase, 50 Hz Ac Input Supply Along With Ac/Dc Terminal & Earthing Slot, Correction Time 10Sec, Std Make , 5Kva Servo Motor Control Voltage Stablizer With Input 100V & Output 220V,Air Cooled,50 Hz,16Swg Steel Body, Copper Wound , Correction Time 10 Sec, Std Make , Auxillary Switch Suitable For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Panel Bush For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Bush(Bus Bar Spout) For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Interruptor Housing For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Limit Switch For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Contact/Female Contact For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make , 36V Tripping Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field, Sudhir Or The Like , 36V Closing Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Sudhir Or The Like , Digital Ammeter/Voltmeter (Programmable)For 11Kv Vcb Panels , Panel Indicators , Ammeter Selector Switch Of 11Kv Vcb , Tnc Switch Of 11Kv Vcb , Spring Charging Motor Of 11Kv Vcb Breaker , Spring Charging Motor Of 33Kv Vcb Breaker , Gears For 11Kv Vcb Of Different Make(Big) , Gears For 11Kv Vcb Of Different Make(Small) , Dc Delco Motor For 33 Kv Vcb , Dc Delco Motor For 11 Kv Vcb , Transormer Oil As Per Is For Power Transformers,Cts,Pts Etc , Distilled Water For Battery Bank , Almunium Alloy Clamps Of Sizes Like Ct,Pt,Pad,Isolator,La,T Etc For 100/200Mmsq Acsr , 33 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250 Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb,Megawin,Sudhir Or The Like , 33K Vcb Bushe Complete Assembly Confirming To Is:2099 Standard , 33Kv /11 Kv Bushes Of Power Transformers Complete Assembly Confirming To Is:2099 Standards , 11Kv/ Lv Bushes Along With Bush Rods Of Auxillary Transformers Complete Confirming To Is: 2099 Standards , 33Kv P.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bush Rod , 33Kv Isolator Grovees(Knife/Tubular Type) Complete , Almunium Tubular Bus Bar As Per Rec , 11Kv G.O Set 400 Amps , 11Kv Isolator, Double Break,3-Pole, 600Amp, Horizental Mounting Type, With Earth Switch. , 11Kv Link Set,Copper Knife(50X6x450)Mm,400 Ampers, Complete With Clamps , 33Kv Link Set,Copper Knife (50X8x600)Mm,800 Ampers, Complete With Clamps Heavy Duty , 33Kv Do / Fuse Set , Distribution Panel (30V, Dc) With 1 No.10Amp. Mccb. Double Pole For Battery Incoming Supply With Dp Mcbs & Indicating Lamps Etc. , Distribution Panel (415 V, Ac) Complete With Ckt. Breakers, Indicating Lamps Etc. , Led Lamps Of Control Room Building ( 9-15 Watts) , Led Lights For Yard( 50 Watts) , Almunium Paint , Red Oxide Paint , Almunium Thimbles Of Sizes(120-600 Sqmm) , 11 Mtr Long S.T Poles (410Sp- 56) Complete With Base And Cap As Per Rec Standard And Specifications , 9 Mtr Long S.T Poles (410Sp- 33) Complete With Base And Cap As Per Rec Standard And Specifications , 13 Mtr Long S.T Poles (410Sp- 69) Complete With Base And Cap As Per Rec Standard And Specifications , 0.2 Acsr (Panther) Conductor , 0.15 Acsr (Wolf) Conductor , 0.1 Acsr (Dog) Conductor , 0.05 Acsr (Rabbit) Conductor , Fabricated Galvanised V -Type Channel Iron X-Arm,6-10 Long Ch Iron,Channel Iron Top,Angle Iron Belts, Clamps & Flat Braces Etc As Per Rec Standard For 33/11Kv Lines. , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm , 33 Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Suitable For 0.1 Acsr Conductor , P G Clamps For 200/150/100Mm Sq Acsr , 33 Kv Danger Plates With Clamps , Anticlimbing Devices With Clamps , Gal Nuts & Bolts With Washers , Earthing Complete By G I Pipe 40Mm Or G I Rod 20Mm 2.5 Mtr Long Through G I Strip As Per Rec Standard , Galvanised Stay Set With 50X8mm Stay Clamps,Guy Insulator,Anchor Plat(300X300x8)Mm,Nuts/Bolts ,Turn Buckle,1.8 Mt Long 20Mm Dia Sold Gs Stay Rod & 7/4.0Mm Dia Gi Std Wire Complete , Guard Netting As Per Rec Standard , Galvanised Spiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard , Porceline 70 Kn Disc Insulator , Porceline 45 Kn Disc Insulator , Porceline 33Kv Insulators (10 Kn) , 33Kv G.I Pins With All Accessories Weighing 2700 Gms , 33Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , 11Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , Electrical Insulating Rubber Mat 6Mm Thickness(1Mrx2mtr). , 63 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , 100 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , Digital Three Phase Voltmeter , Porceline 11Kv Insulators , 11 Kv G.I Pins With All Accessories , Coper Bus Bar , Drill Bilts Of Sizes 3/4 And 1 , Hexa Blade , Round Hexa Blade , Welding Rods , Bush Rods For 10Mva, 6.3 Mva , Monoplastic Tape Rolls , 11Kv Pannel Hrc Fuses , Ac/Dc Mccb Of Different Ratings , Oil Temperature Indicator Of Reputed Make For 33/11-6.6Kv Power Transformers , Winding Temperature Indicator Of Reputed Makefor 33/11-6.6Kv Power Transformers , Standard Quality Silica Gel For Various Capacity 33/11Kv Power Transformers , Breaker Mechanism Of Reputed Make , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Sauitable For 0.15/0.2Acsr , 2.5 Sqmm 12 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 33Kv Grade, 1 Core Heat Shrinkable Jointing Kit, Including Required Size Of Lugs/Thimbles, As Per Relevent Is Specification 7098 (Part-Ii) 3M/ Raychem Suitable For 630/400/300Sqmm , Buchholz Relay For 33/11-6.6Kv Transformer Protection , Twin Bimettalic Clamps Aaac Equivalent 8 Bolt Type With Four Outputs As Per Relevant Is Standard Suitable For 01/0.2Acsr , Ht Tape Roll As Per Is Standard With Latest Ammendments , Indication Lamps Suitable For 33/11Kv Panel Board Ike Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir / Pascal/Hartek Make , Monoplast Tape As Per Is Standard With Latest Ammendments , Lt Insulation Tape As Per Is Standard With Latest Ammendments , Old Sarees , Earthing Electrodes As Per Is Standard With Latest Ammendments , 11Kv Auxillary Relays. , Al Alloy Tension Fittings Suitable For 50/100/150/200 Sqmm Acsr As Per Rec , Almunium Folded Ladder , Bus Bar Type Clamp For Connecting Ic Cable Outdoor , Water/Snow Resistant Shoes (Tsf Make Or Any Equivalent Brand) , Rain Coat Long Size Over Coat Type (Size 4Xl) , Umberlla Big Size , Safety/ Industrial Helmet With Straps Isi Mark, With Head Lamp Bracket And Detachable And Interchangeable Led Headlamp Alongwith Charger/Charging Facility(Color:- White , Blue And Yellow ) , Chainsaw Cutter Heavy Duty 1800-2500 W , Chainsaw Cutter Heavy Duty (Portable) 1000-1500W , Searchlight Heavyduty (Eveready, Panasonic/Philips Or Equivalent) , Heat/Flame Gun Metallic For Cable Kit Shrinking With Portable Butane Gas Can 225G Of 01No. , Butane Gas Cartridges/Canisters, Refill Fuel For Welding Torch, 225G , Electric Heat Gun For Cable Kit Shrinking 1000-200 Watt , Heavy Duty Tool Kit (Flat/Round Spanner Set, Plier, Screw Driver Set, Wire/Cutter/Striper, File With Torque Spanners Set Etc Complete Set) , Al. Ladder Foldable 2X20 Ft. Telescopic Portable Ladder , Digital Megger 5 Kv , Digital Megger 2.5 Kv , Cork Sheet 4Mm , 2V Battery 100Ah Vrla Type Of Standard Make , 2V Battery 200Ah Vrla Type Of Standard Make , 12V Battery 200Ah Lead Acid Type Of Standard Make , 33 Kv Current Transformer Outgoing/Incomer (33 Kv, 1Φ, Multi Ratio Multi Core 600-300/1A, Indoor Type) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted At Pahalgam , 11 Kv Current Transformer Outgoing (11 Kv, 1Φ, Multi Ratio Multi Core 200-400/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted (Pahalgam) , 11 Kv Current Transformer Incommer (11 Kv, 1Φ, Multi Ratio Multi Core 900-600/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station (Pahalgam) , 33 Kv Single Core Indoor Cable Kit ( Plug In Tremination Type And Screened Seperable Connectors ) For 400 Mmsq Cable For Gis Compatible Substaion (Brand:- Euromold, Nexans, Raychem Etc) , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 33Kv 1Corex400nmsq,Nndia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 11Kv 1Corex 400Mmsq,Ins Dia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Inner Core Plug In Termination Kit To Suit Size-3-Lcx630mmsq 12/20(24Kv) installation Dia: 34.0-45.06 Complete Set With All Accessories Per Set Of 3Nos Of Standard Make Gis Compatible Substation , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,630 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 11Kv 3 Core Cable Jointing Kit Of Sizes 185/240/300/400 Sqmm , 11Kv 1 Core Cable Jointing Kit Of Sizes 185/240/300/400/630 Sqmm , ⁠630 Mmsq Hydrolyic Crimping Tool , ⁠Electric Grinder 700 To 1000 W Of Standard Make , Electric Digital Welding Machines (Portable Of 100 - 250 Amps , 11Kv Cable Jointing Kit , Oil Pump Manual Of Standard Make For Transformers , Foam Spray Sealant Tins Of 450Ml , Vaseline/Grease , 11Kv Cts Of Different Ratios And Make Like Electricfield, Pasxcal, Sudhir, Stelmac Etc.) , T Clamps For Acsr 200Mmsq , Retaining Pins, Lock Nuts Of Sizes, External Retaining Rings(Rotor Clips, E Clips, C Clipso/S, Split Pins/Cotter Pins O/S , Single Phase 1 Hp Water Motor Of Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
20.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
21.
Housing Urban and Rular Development #11189008 AOC
Supply Of Water Supply Materials In The Villages Coming Under The Gonisomanahalli Gram Panchayat. - Mdp Pipe (Wtr Supply Items),Non-Return Valve 50 Mm Dia (Wtr Supply Items),Sluice Valve Pn -10.0 And 80Mm (Wtr Supply Items),Air Valve 80Mm Dia (Wtr Supply Items),Teflon Tape (Wtr Supply Items),Gi Pipe 20Mm (Wtr Supply Items),Tap (Wtr Supply Items),Air Valve Pn 16.0 (Wtr Supply Items),Sluice Valve Of Pn -10.0 And 80Mm (Wtr Supply Items),Sluice Valve Of Pn -10.0 And 50Mm (Wtr Supply Items),Electro Fusion End Cap With Pipe Of 0.2M Length (Wtr Supply Items),Electro Fusion Reducer 75 X 63Mm Dia (Wtr Supply Items),Electro Fusion Elbow 75 Mm (Wtr Supply Items),Electro Fusion Elbow 63 Mm (Wtr Supply Items),Electro Fusion Tee 75 Mm (Wtr Supply Items),Electro Fusion Tee 63 Mm (Wtr Supply Items),Electro Fusion Coupler 75 Mm (Wtr Supply Items),Electro Fusion Coupler 63 Mm (Wtr Supply Items),Pe100 Pn-6 Pe100 63Mm (Pn 10/10 Kg/Cm2) (Wtr Supply Items),Pe100 Pn-6 Pe100 75Mm (Pn 10/10 Kg/Cm2) (Wtr Supply Items),Hdpe Pipe Pe100 75Mm (Pn 6.0/6 Kg/Cm2) (Wtr Supply Items),Hdpe Pipe Pe 100 63Mm (Pn 6.0 / 6 Kg/Cm2) (Wtr Supply Items),Gum 500Ml Ap (Wtr Supply Items),Gum 250Ml Ap (Wtr Supply Items),Gum 100Ml Ap (Wtr Supply Items),Gum 50Ml (Wtr Supply Items),Gum 25Ml (Wtr Supply Items),Pvc Ball Valve 75Mm (Wtr Supply Items),Thread Gate Valve 63Mm (Wtr Supply Items),Pvc Ball Valve Heavy 63Mm (Wtr Supply Items),Pvc Ball Valve Light 63Mm (Wtr Supply Items),Ball Valve 40Mm (Wtr Supply Items),Ball Valve 25Mm (Wtr Supply Items),Ball Valve 20Mm (Wtr Supply Items),Mta 20Mm (Wtr Supply Items),Service Saddel 63X20mm (Wtr Supply Items),Service Saddel 75X20mm (Wtr Supply Items),Reducer Tee Pvc 75X63mm (Wtr Supply Items),Reducer Pvc 75X63mm (Wtr Supply Items),Tread Elbow 63Mm (Wtr Supply Items),Fta Pvc 63 Mm (Wtr Supply Items),Tread Cap 63 Mm (Wtr Supply Items),Mta Pvc 63 Mm (Wtr Supply Items),End Cap 180Mm (Wtr Supply Items),End Cap 75 Mm (Wtr Supply Items),End Cap 63 Mm (Wtr Supply Items),End Cap 40Mm (Wtr Supply Items),End Cap 25Mm (Wtr Supply Items),End Cap 20Mm (Wtr Supply Items),Long Bend 4 Kg 75Mm (Wtr Supply Items),Long Bend 6Kg 63Mm (Wtr Supply Items),Long Bend 4Kg 63Mm (Wtr Supply Items),Repair Coupler Pvc 4Kg 90Mm (Wtr Supply Items),Repair Coupler Pvc 4Kg 75Mm (Wtr Supply Items),Repair Coupler 6Kg 63Mm (Wtr Supply Items),Repair Coupler 4Kg 63Mm (Wtr Supply Items),Pvc Collar 4 Kg 90Mm (Wtr Supply Items),Pvc Collar 4 Kg 75Mm (Wtr Supply Items),Pvc Collar 6Kg 63Mm (Wtr Supply Items),Pvc Collar 4Kg 63Mm (Wtr Supply Items),Pvc Tee 6Kg 90Mm (Wtr Supply Items),Pvc Tee 6Kg 75Mm (Wtr Supply Items),Pvc Tee 6Kg 63Mm (Wtr Supply Items),Pvc Elbow 4G 110Mm (Wtr Supply Items),Pvc Elbow 90Mm (Wtr Supply Items),Pvc Elbow 6Kg 75Mm (Wtr Supply Items),Pvc Elbow 6Kg 63Mm (Wtr Supply Items),Pvc Elbow 6Kg 40Mm (Wtr Supply Items),Pvc Elbow 25Mm (Wtr Supply Items),Pvc Elbow 10Kg 20Mm (Wtr Supply Items),Pvc Pipe 6Kg Ap 200Mm (Wtr Supply Items),Pvc Pipe 6Kg Ap 180Mm (Wtr Supply Items),Pvc Pipe 4 Kg Ap 180Mm (Wtr Supply Items),Pvc Pipe 4 Kg Ap 110Mm (Wtr Supply Items),Pvc Pipe 4Kg Ap 90Mm (Wtr Supply Items),Pvc Pipe 4Kg Ap 75Mm (Wtr Supply Items),Pvc Pipe 6Kg Ap 63Mm (Wtr Supply Items),Pvc Pipe 4 Kg Ap 63Mm (Wtr Supply Items),Pvc Pipe 6 Kg Ap 40Mm (Wtr Supply Items),Pvc Pipe 8Kg Ap 25Mm (Wtr Supply Items),Pvc Pipe 10Kg Ap 20Mm (Wtr Supply Items),G I Nipple 3/4 Inch (Wtr Supply Items),G I Nipple 1/2 Inch (Wtr Supply Items),G I Reducer 3/4X1/2 (Wtr Supply Items),G I Collar 3/4 Inch (Wtr Supply Items),G I Collar 1/2 Inch (Wtr Supply Items),Polo Tap (Wtr Supply Items),Pvc Tap 3/4 Inch (Wtr Supply Items),Pvc Tap 1/2 Inch (Wtr Supply Items),G I Tap 3/4 Inch (Wtr Supply Items),G I Tap 1/2 Inch (Wtr Supply Items),Pump Set 2 Hp 25Stg (Wtr Supply Items),Pump 16 Stage (Wtr Supply Items),Submersible Pump Set 12.5Hp 24Stg (Wtr Supply Items),Submersible Pump Set 10Hp 20 Stg (Wtr Supply Items),Submersible Pump Set 7.5Hp 16 Stg (Wtr Supply Items),Connector 3 Wat (Wtr Supply Items),Connector 5 Way (Wtr Supply Items),Metering Pannel (Wtr Supply Items),Voltmeter (Wtr Supply Items),Amps Meter (Wtr Supply Items),Breaker (Wtr Supply Items),Reel 4 Way (Wtr Supply Items),Aluminium Wire 16Sqr (Wtr Supply Items),Aluminium Wire 12Sqr (Wtr Supply Items),Aluminium Wire 10Sqr (Wtr Supply Items),Aluminium Wire 6Sqr (Wtr Supply Items),Core Submersible Cable 6 Sqr 3 (Wtr Supply Items),Core Submersible Cable 2.5Sqr 3 (Wtr Supply Items),Core Submersible Cable 4Sqr 3 (Wtr Supply Items),Wire Copper 1Sqr (Wtr Supply Items),Wire Copper 2.5Sqr (Wtr Supply Items),Wire Copper 4Sqr (Wtr Supply Items),Wire Copper 6Sqr (Wtr Supply Items),Wire Copper 720 (Wtr Supply Items),Fuse Wire (Wtr Supply Items),Fuse 32 Amps (Wtr Supply Items),Fuse 100 Amps (Wtr Supply Items),Fuse 63 Amps (Wtr Supply Items),Auto Starter (Wtr Supply Items),Preventer 12Hp (Wtr Supply Items),Preventer 8Hp (Wtr Supply Items),Contactor Set (Wtr Supply Items),Relay 20/32 Amsp (Wtr Supply Items),Base No 10 (Wtr Supply Items),Ch Point Set (Wtr Supply Items),Ch Coil (Wtr Supply Items),Starter Coil Lt/Lk (Wtr Supply Items),Point Set Lt/Lk (Wtr Supply Items),Delta Starter (Wtr Supply Items),Digital 3 Phase Starter Set (Wtr Supply Items),Starter Ajantha 20/32 Amps (Wtr Supply Items),Round Clamp 40Mm (Wtr Supply Items),Ss Nipple 40Mm (Wtr Supply Items),G I Nipple 40Mm Light (Wtr Supply Items),Bore Cap 40Mm (Wtr Supply Items),Non Return Valve 40Mm (Wtr Supply Items),Gi Clamp Set 40Mm Hy (Wtr Supply Items),G I Bend 40Mm Hy (Wtr Supply Items),Gi Colour 40Mm Hy (Wtr Supply Items),Nrv Stone (Wtr Supply Items),Ss Bolt Nut (Wtr Supply Items),Nrv Washer (Wtr Supply Items),Flange Set 50Mm (Wtr Supply Items),G I Tee 50X20mm (Wtr Supply Items),Clamp Set Hy 50Mm (Wtr Supply Items),Bore Cap Hy Steel 50Mm (Wtr Supply Items),Bore Cap Light 50Mm (Wtr Supply Items),Nipple Hy 1.5 Feet 50Mm (Wtr Supply Items),Nipple Light 50Mm (Wtr Supply Items),G I Bend Light 50Mm (Wtr Supply Items),G I Bend Hy 50Mm (Wtr Supply Items),Nrv Flange Type 50Mm (Wtr Supply Items),Non Return Valve Ball Type 50Mm (Wtr Supply Items),G I Collar Light 50Mm (Wtr Supply Items),G I Collar Hy 50Mm (Wtr Supply Items),Gi Pipe 50Mm (Wtr Supply Items),Wire (Wtr Supply Items),Twin Wire Pvc (Wtr Supply Items),Thread (Wtr Supply Items),Shallock (Wtr Supply Items),Impeller K40 Inch Or K80 Inch (Wtr Supply Items),Motor I P (Wtr Supply Items),Oil Seal (Wtr Supply Items),Flange (Wtr Supply Items),Test Bearing Lock (Wtr Supply Items),Shin Guard (Wtr Supply Items),Coupling (Wtr Supply Items),Shim Washer (Wtr Supply Items),Studs (Wtr Supply Items),Nut Ss 8Mm (Wtr Supply Items),Nut Ss 10Mm (Wtr Supply Items),Test Bearing Set 90Mm (Wtr Supply Items),Test Bearing Set 80Mm (Wtr Supply Items),Motor Circlip (Wtr Supply Items),Motor Shaft (Wtr Supply Items),Chavi Small (Wtr Supply Items),Chavi Long (Wtr Supply Items),D O Bush Gm (Wtr Supply Items),Ip Bush Gm (Wtr Supply Items),Circlip (Wtr Supply Items),Sleeve Ss (Wtr Supply Items),Stage Bush Rubber (Wtr Supply Items),Stage Bush Gun Metal (Wtr Supply Items),Rotar Bush (Wtr Supply Items),Pump Jali (Wtr Supply Items),Motor Jali (Wtr Supply Items),Water Proof Tape (Wtr Supply Items),Milk Paper (Wtr Supply Items),Sleeve 20X27x25 (Wtr Supply Items),Sleeve (Wtr Supply Items),Insulating Tape (Wtr Supply Items),Winding Paper (Wtr Supply Items),Stick (Wtr Supply Items),Winding Wire 0.7 To 1Mm (Wtr Supply Items),Winding Wire 1.1 To 1.4Mm (Wtr Supply Items)
Contract Date: Ref. Documents Contract Value : 3.67 Lakh
Local Bodies No of Bidders 1
23.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
25.
Drinking Water Supply and Sanitation #11129348 Technical Bid
Tender for Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (50 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (70 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (95 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (120 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (185 Sqmm Size) , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 250 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 400 Mm Nominal Diameter , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 400 Mm Nominal Diameter , Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Repects. , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Providing, Fixing, Jointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Ns Item -Providing And Fixing Of Ci Sluice Valves Conform To Is 14846 / Din 3352, With Length Over Flanges As Per Pd Or Alt 1 Of Is 14846 Corresponding To Bs En - 558 / Iso 5752 Basic Series 3 And 15 Respectively Including Labour, Material, Joints. Make: Ivc / Vag / Kirloskar Complete In All Respect As Per Specifications Mentioned In Dnit 800 Mm I/D , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 13200 Lpm X 20 Mtr. Head (For Mps Idgah Road) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 8800 Lpm X 20 Mtr. Head (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 100 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 65 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 35 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 4000 Lpm X 30 Mtr. Head (For Ips Mc Land) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 7800 Lpm X 30 Mtr. Head (For Ips Mc Land) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 11800 Lpm X 30 Mtr. Head (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 130 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 90 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 45 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 35 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips-2 Near Stp) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 75 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips-2 Near Stp) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 9600 Lpm X 20 Mtr. Head (For Ips-2 Near Stp) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
26.
Power #11110319 Technical Bid
Tender for Rate Contract For Procurement Of Material That May Be Required During The Emergencies For The Year 2026-27 In Respect Of Ed-3Rd , Supply Of , 50 Mm² Ab (Ht) Cable (3X50 + 1X70 Mm²) Xlpe(11 Kv, 3C + Earth) , 70 Mm² Ab (Ht) Cable (3 X 70 + 95 Mm²) Xlpe(11 Kv, 3C + Earth) , 120 Mm² Ab (Ht) Cable (3X120 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 150 Mm² Ab (Ht) Cable (3X150 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 185 Mm² Ab (Ht) Cable (3X185 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Upto 50- 95 Sqmm ( 3 Core) , Heat Shrinkable Outdoor Cable Termination Kit Above 120 To 185 Sqmm ( 3 Core) , Mid Span Straight Through Jointing Kit For 11 Kv Abc 120 -185 Sqmm , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 95 Mm² Ab (Lt) Cable ( 3 X 95 + 1 X 16 + 1 X 70 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 16 + 1 X 70 Mm²) Xlpe (1.1Kv, 3+1 C, Al) , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 95-150 Sqmm , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 35-70 Sqmm , 70 Mm² Single-Core Cable, 1.1Kv Grade, Xlpe Un-Armoured Frls Type , 95Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 120 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 150 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 185 Mm² Cable, 1.1Kv Grade, Xlpe Un Armoured Frls Type , 240 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 300 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 400 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 500 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 630Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 10 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 10 Mm² Cable (4C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (4C),1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 25 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , 35 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , Single Core 1 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 1.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 2.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 4 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 6 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , 11 Kv, 3- Core Xlpe 35 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 50 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 70 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 120 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 150 Mm² Round Wire Armoured, Frls Cable , 11Kv, Three Core 185 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11 Kv, 3- Core Xlpe 240 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 400 Mm² Round Wire Armoured, Frls Cable , 11 Kv End Termination For 3C 120- 185 Mm² , 11 Kv End Termination For 3C 240 To 400 Mm² , 11 Kv Straight Through Jointing Kit Upto 50-95 Mm² , 11 Kv Straight Through Jointing Kit Upto 120-185 Mm² , 11 Kv Straight Through Jointing Kit Upto 240-300 Mm² , 11 Kv Straight Through Jointing Kit Upto 400 Mm² , Lt Distribution Box For 25 Kva Dtr With 40 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 25 annual periodical maintenance Mccb 3P 16 Ka/10 Ka 1 No. Each (=2No.) For Outgoing Circuits . , Lt Distribution Box For 63 Kva Dtr With 100 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 63 annual periodical maintenance Mccb 3P 16 Ka 1 No.S For Outgoing Circuits , Lt Distribution Box For 100 Kva Dtr With 160 Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 200 Kva Dtr With 315 annual periodical maintenance Mccb 3P 25 Ka For Incomer & 160 annual periodical maintenance Mccb 3P 16 Ka 3 No.S For Outgoing Circuits , Lt Distribution Box For 250 Kva Dtr With 400 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 160 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Temporary Lt Fuse Set For Distribution Transformers (Customised) As Per Kpdcl Drawing No. Ce/P&P/Drg/2023/Ltfs/001 (Enclosed) , 11Kv Polymeric Composite Disc Insulator 12Kv,Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm Nos , 11Kv Polymeric Composite Pin Insulator 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 16 Kn Polymer Shackle Insulator , G.I Mukey For Shackle Insulators With Bolt Of (50X8)Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 258 Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 369 Mm , 11 Kv Link Set Heavy Duty With Copper Blade Size Of 14 Inch, 50 X 6 Mm, Female Contact Of Copper 6 Mm Thickness, With Post Insulator Of 10 Kn , 11 Kv Go, Ab Switch 3-Phase, 3-Pole,200 Amp, Vertical Type Set , 11 Kv Horn Gap Fuse Set 3 Phase 200A Set , Pg Clamps For 30 Mm² Acsr Conductor , Pg Clamps For 50 Mm² Acsr Conductor , Pg Clamps For 100 Mm² Acsr Conductor , Suspension/Tension Clamp With Eye Hook , Gi Pole Support Clamp Including Gi Nut And Bolts For 11 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 9 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr With Size 50X 8X 328 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr Or 9 Mtr Plain Cement Concrete With Size 50X8x441mm , Cable Tie (Each Packet Contains 100 Nos.) , Cable End Caps , Insulating Piercing Connectors Of Sizes , 11 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 11 Kv Ipc For Covered Conductor To Covered Conductor Connection , 33 Kv Tension Clamps With Bail And Ipc (Insulation Piercing Conductors) , 33 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 33 Kv Ipc For cement concrete To cement concrete Connection , 33 Kv Ipc With Aluminium Bail For Earthing , Main Single Phase Service Distribution Box (Pole Db) Along With Mccb /Mcb As Per Rec Drawing. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Main 3 Phase Distribution Box Ip 54 (Pole Db) Made From 20 Swg Crca Ms Sheet By Deep Drawn Method With Powder Coating. Internal Size Of The Box Shall Be 225Mm X 285Mm X 120Mm Used For Connection Through Abc Line And For Giving Connections To The Consumers 3Phase-1 Incoming 4 Outgoing I/C- 1, O/G-2-4 (200 A, 0.415 Kv) For Ryb Phase. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Lt Line Spacers 3 P ,4 Wire , Lt Line Spacers 2 P ,3 Wire , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 3-Ø, 4-Wire Trivector Meter (Prodigy ) With Suitable Ring Type Ct 200 annual periodical maintenance (Net Meter Enabled) , Single Phase Smart Energy Meter 5-30 Amp/ 10-60 Amp, Dlms Complaint Of Accuracy Class 1.0 , Three Phase Smart Energy Meter 20-80 Amp/, Dlms Complaint Of Accuracy Class 1.0 , Polypropylene Weather Proof Outdoor Type Meter Box For Single Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For Three Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For 4 Single Phase Meter Along With Zinc Plated Clamps , Gi Barbed Wire For Anti Climbing , Danger Plates With Clamps , Anti-Climbing Device With Clamps , Cemical Earthing Complete , Earthing Mat (Gi Flat 50 Mm X8 Mm)/(75 X10)Mm/(75X8)Mm , Gi Pipe 40 Mm 3 Mtr Long For Earthing , Earthing Electrode ( 3M Long) 20 Mm Dia. , Gi Strip 25X3 Mm , Galvanized Earthing Strips 50Mm X3mm. , Red Oxide , Aluminium Paint , Galvanized Nuts And Bolts , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2No..), Anchor Plate (200X 200 X 6 Mm), Nut-Bolts, 2 No. Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (11 Kv) , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2Nos.), Anchor Plate (300X 300 X 8 Mm), Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (33 Kv) , Gi V Cross-Arm With Top Bracket Of Sizes , Gi Channel X-Arm And Braces Of Sizes , Gi Extension Riser Of Sizes , Gi Wire 6 Swg & 8 Swg , Guard Netting (For 52 Mtr Span) , Aluminium Jointing Sleeves 100 Sqmm , Aluminium Jointing Sleeves 50 Sqmm , Aluminium Jointing Sleeves 30 Sqmm , Suspension Fitting (2 Bolt) For 11 Kv Line , Tension Fitting (4 Bolt) For 11 Kv Line , Suspension/Tension Clamp With Eye Hook , Earth Wire 7/4 Sqmm , 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation, Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Service Pillar. , 3 Phase, 415V, 1No Of 250 Amps Incoming 3 Tp Mccbs (Breaking 36Ka) Fitted Withoutgoing 03 No 100 Amps Sp Mccbs, 1No.100Amps 3 Pole Mccb For Outgoing Lt Cables, Distribution Feeder Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 4P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Feeder Pillar. , Fire Extingiusher Co₂ Type Of 4.5 Kg Capacity For Control Room , 3 Sand Bucket Fire Extingiusher , Gum Boots With Steel Toe Of Sizes , Winter Jacket- Coat Ecc Consists Of Three Independent Components That Is Wind Cheater ( Waterproof ), Insulating Layer And Waist Coat ( Sleeve Less ), Three Layer Waterproof Breathable Fabric, Dual Shade Og/ White, Material Of Insulating Layer- 1. Batting Polyester, 100 Gsm, 2. Fabric Nylon Knitted Aluminized, 3. Fabric Nylon 75 Gsm White, Material Of Waist Coat- Double Layer Bonded Polyester Fleece , Safety Vest - Reflective Luminous Garments - High Visibility Warning Garments With Synthetic Slide Fasteners, Fluorescent Yellow, Width Of Retro Reflective Material For All Types Of Garments (Minimum) 50 Millimeter , Non-Contact Voltage Detector, Upon Detection, Tip Glows And Beeper Sounds, Cat Iv 1000 V For Added Protection, Expanded Range: 90 V To 1000 V Ac Or 200 V To 1000 V Ac, Battery Cell Operated (2 Aaa Or Standard), Voltbeat Technology And Continuous Self-Test , Safety Helmet- Quality Of Shell High Quality, High Impact, Light Weight,Tough, Conformity To Specification- Is 2925:Latest ,En 397 Certified , Safety Rubber Gloves Up To 15 Kv As Per Iec Standard , Safety Belt/Harness With Shock Absorber , Safety Shoes Of Sizes -Personal Protective Equipment - Safety Footwear As Per Bis Specification No Is 15298 ( Part 2 ): 2016, Toe Cap- ( Steel ) Metallic, Insole, Classification- Class I ( Footwear Made From Leather And Other Materials, Excluding All-Rubber Or All-Polymeric Footwear ) With Different Sizes, Slip Resistant- As Per Clause 5.3.5.4 Of Is 15298 ( Part 2 )- Slip Resistance On Ceramic Tile Floor With Nals And On Steel Floor With Glycerine. , 11 Kv Earthing/Discharging Rod (Set Of 3 Rods) Set With Minimum 20 Sqmm Cable And U-Clamp , Battery Operated 12 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Alumunium Ladder 2*15 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Aluminium Ladder 2*10 Ft Long, Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope , Bamboo Ladder 18 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Bamboo Ladder 20 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Wart Free Budloo Wooden Ladder 17 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Wart Free Budloo Wooden Ladder 20 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Telescopic Ladder 20 Ft Long, 6063 T5 Grade Of Aluminium , 150 Kg Load Capacity, Self Locking Mechanism, Anti-Skid Foot Caps , Hand Held Search Light Led Lamp, 100 Watt With Lithium Ion 3.7 V, 3.5 Ah, 500 Lux/100 Mtr With Lamp Life -50000 Hours, Ip 65, 12 Months Warranty , Hdpe Pipe Outer Dia 180 Mm Inner Dia 152 Mm For Laying Of 11Kv Xlpe Cable From Power Transformer To Control Room , Mccb - 200 Amps,36Ka,4P Adjustable , Mccb - 40 Amps,36Ka,4P Adjustable , Mccb - 63 Amps,36Ka,4P Adjustable , Mccb - 100 Amps,36Ka,4P Adjustable , Mccb - 160 Amps,36Ka,4P Adjustable , Mccb - 250 Amps,36Ka,4P Adjustable , Mccb - 400 Amps,36Ka,4P Adjustable , Mccb - 630 Amps,36Ka,4P Adjustable , Mccb - 200 Amps,36Ka,3P Adjustable , Mccb - 100 Amps,36Ka,3P Adjustable , Mccb - 160 Amps,36Ka,3P Adjustable , Mccb - 250 Amps,36Ka,3P Adjustable , Mccb - 400 Amps,36Ka,3P Adjustable , Mccb - 630 Amps,36Ka,3P Adjustable , Bobin Insulators Clamps/Cliffs. , Epoxy Resin Cast Panel Insulators Upto 500Mm , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Al. Solderless Clamps Suitable For Transformer 1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 63 Kva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 50 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , Aluminium Thimbles 10 Mm2 As Per Relevant Is , Dpc Copper Winding Wire (Round) In Sizes 11 To 22 Swg Fresh. , Dcp Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 250 Kva To 630 Kva Fresh. , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg. , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg-Fresh , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva - Fresh , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg-Fresh , Dpc Copper Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Lv Brass Bush Rods 12 Mm , Lv Brass Bush Rods 19 Mm , Lv Brass Bush Rods 25 Mm , Lv Brass Bush Rods 32 Mm , Press Card Board Soft Calendared Solid 1Mm/2Mm/3Mm(As Per Sample) , Press Card Board Pre Compressed Solid 1Mm/2Mm/3Mm. , Ht Insulating Gum , Glass Wool Sleeves Of Sizes , Aluminium Brazing Rod (Standard Length) , Copper Brazing Rod (Standard Length) , Flexible Copper Strip (Shim) 75Mm X 0.5 Mm , Pvc Sheets 1 Mm Thick , Empire Tape 1 , Electrical Grade Kraft Paper, 4 Mil , Leatheroid Insulation Paper 20 Mil. , Hv Bushing , Lv Bushes Suitable For 63 To 100 Kva Dt , Lv Bushes Suitable For 200 To 250 Kva Dt , Lv Bushes Suitable For 400 To 630 Kva Dt , Epoxy Resin Cast 1.1 Kv Low Voltage Transformer Bushing With Busbar For 400/630 Kva Dt , Cotton Tape 1 (Size) 35 M Long. , Rubber Washers , Ht Paper , Cork Washer 12Mm Dia , Cork Washer20mm Dia , Cork Washer 25Mm/30Mm Dia , Plastic Metre Seals , Trifor (Tower Roller) , Transformer Oil Filitration Plant Filter Elements Of 1 Micron(60X250) Mm For Transformer Oil Filitration Plant , Heating Elements Of 2000 Watts For Transformer Oil Filtration Plant , Press Cardboard Cutter Having Bed=52X21 With Height Of Machine 45 With No. Of Tensile Springs 2 Nos. Complete In All Respects. , Angle Grinder, 800W Power, No-Load Speed Of 11000 Rpm, 100 Mm Disc , Welding Machine(Inverter Type) =5=10 Kva Rated Input Power, Maximum Welding Current At 60% Duty Cycle (In A) 150=250, Adjustable Hot Start,Anti-Stick Functions,Arc Force Control , Cordless Impact Drill/Drivers With 2 Batteries, Ideal For Driving Screws Into Wood And Drilling Into Masonry, Metal, And Wood , Pneumatic Air Impact Wrench With Sockets From 15 To 30 , Air Compressor 50 Ltr , Hand Held Brush Cutter , Hydraulic Crimping Tool , Pallet Truck 3 Ton , Hand Driven Insulation Resistance (Meggar) , Multimeter(Analog) , Multimeter(Digital) Voltage: Dc: 1000 Volts; Ac: 1000 Volts; Dc Accuracy: ± 0.5% + 3 Digit; Ac Accuracy: ± 1% + 3 Digit; Current: Dc: 10 Amps; Ac: 10 Amps; Dc Accuracy: ± 1.5% + 3 Digit; Ac Accuracy: ± 1.5% + 3 Digit; Resistance: 40 M Ohm; Resistance Accuracy: ± 1.5% + 3 Digit ; Capacitance: 1000 Μf; Capacitance Accuracy: ± 5% + 5 Digit Cat Iii 600 Volts Safety Rating , Pliers -Type Of Hand Tool-Combination Plier As Per Is 6149, Type Of Insulation-Rubber Insulation, Material-Carbon Steel , Nawara Tape 1 (Size) 35 M Long. , Rubberized Cork Sheet 4 Mm Thick 2Ftx3ft , Rubberized Cork Sheet 3Mm Thick 2Ftx3ft , Bakelite Tubes 12Mm Dia ( 1 Mtr Long) , Hv Bush Clamps (Ms) , Aluminium Clamping Member (Shoes) For Hv Bushing , Lv Cork Washers 12 Mm Dia , Lv Cork Washers 20Mm Dia , Lv Cork Washers 25 Mm/30 Mm Dia , Nuts & Bolts (M.S) Of Sizes. , M.S Flat Washers. , Hv Cork Washers 110 Mm O.D , Aluminium Welding Flux , Aluminium Flat 4/6/8/10 Mm Thick Of Required (Busbar) , Copper Flat 4/6/8/10 Mm Thick Of Required Width. (Busbar) , Ms Plug & Caps 1/2 ; 3/4; /1; 1.1/4; 1.1/2 , Oil Seal Rings (O-Rings) For Lv/Hv Bush Rods 12 Mm Dia. , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 20 Mm Dia , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 25 Mm Dia , Creep Tape 1 , Cotton Cloth , Empire Sleeves Of Sizes , Synthetic Enamel Paint Smoke Grey Colour , Paint Thinner , Steel Primer , Silica Gel , Transformer Oil As Per Is 335 And Amendments Thereof , Welding Rods 3.15 Mm/4Mm. (100 No. Per Packet) , Refilling Of Oxygen Gas For Brazing , Refilling Of Lpg Gas For Brazing , 12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(Adjustib And 1-Piece Measuring Tape) Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 12 Volts, 42 Ah Lead Acid Battery , 12V 7 Ah Rechargeable Sealed Maintenance Free Battery (Smf) For Ups , Battery Connector For 12 V Battery Bank (12 No. Both Ends Of Each Connector Should Be Properly Clamped With Nuts, Bolts, Washers) , Fabricated Gi Pollar Collar 50X6 Mm With Nuts And Bolts , Digital Weighing Scale Upto 1 Ton , Portable Professional Petrol Chainsaw,18 Inch Or Above, 2 Kw Or Above, Pitch Of 3/8 Or Above, Petrol Capacity 400 Ml Or Above. , Double Ply Polyester Webbing Slings, Load Capacity 6 Tonne , Dee Shackles Forged Shackles, Working Load 6.5 Tonne , Eyebolt With Recessed Collar With Maximum Axial Lifting Capacity Of 6 Tonne , Handheld Brush Cutter / Line Trimmer, With Nylon Feed Head Attachment Petrol Engine Low Vibration Centrifugal Clutch, Hardened Steel 2 Teeth Blade, Bump / Tap & Go Type, Shaft Length (Mm) 1425 To 1449, Circular Saw Attachment Inclusive In The Scope Of Supply , Portable Hydraulic Crimping Tool For 30 Sqmm To 400 Sqmm With All Attachments , Pre Fabricate Galvanized Single Way Top Bracket (1000 Mm Long With 48.3 Od Gi Pipe) To Be Fitted On Top Of Octogonal Pole For Holding Lighting Luminaries. , Dk Thermoplastic Cable Junction/ Termination T Boxes 8X10Of Class Ip55/Ip65 Fitted With Two 2-5 annual periodical maintenance Mcb Strip,4-Way Terminal Block / Connectors Incl. Copper Lugs, Clamps ,Nut & Bolts Washers Etc (Hansel Or Equivalent Make) Or Poles With Two Way Type Bracket To Be Fitted Properly Inside The Door Opened Gear Box Provided On Thebottom Side Of The Pole. , Surge Protector For The 120/190 Watt Led Type Lighting Fixture Complete. , Outdoor Type Lt Control Panel Size 900Mmx900mmx450mm Having Input Main Control Of 100 annual periodical maintenance Mccb With Tpn Bus Bar With 40 annual periodical maintenance Tpn Mcb 4Nos For Outgoing Circuits,Including Astronomical Switching With Contactor Of Required Capacity. The Panel Should Be Fitted With A Digital Composite Voltmeter/Ampermeter/Indicator Set With Selecter Switch And Backup Protection System, Thimbling And The Panel Shall Further Be Provided With Proper Openings On Front Side As Well As On Rear Side Including Its Locking Arrangement And Also With Required Glands And 4No. Angle Iron Legs For Grouting The Panel On Bed , The Panel Shall Also Be Provided With Powder Coat/Pu Paint. The Item Includes Its Thimble As Required At Taping Point For Incomming , Out Going And Internal Panel Wiring Complete Unit. , Dust/Rain/Snow-Proof Canopy Type Mini-Outdoor Lt Feeder Panel Of Size 450X300mm With Front Door Opening Duly Powdered Colour Coated With Inbuilt 2No Tpn 16-32 annual periodical maintenance Mccb,Tpn Busbars Of Same Capacity Installed On Cement Concrete Block With 4 Angle Iron Legs Grouted In The Cement Concrete Of Termination Of Main 25Sqmm Cable And Outgoing 25/16 Sqmm Cable Circuits. , 120 Watt Led Luminaries Of Ip 67 Protection. , 190 Watt Led Luminaries Of Ip 67 Protection. , 110 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 70W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 50 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 30W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 6 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 10 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1Pole With 1Pp, 240 V , 10 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 240 V , 16 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 16 A Spn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2Pole With 1Pp, 415 V , 16 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3Pole With 3Pp, 415 V , 32 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , 32 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3 Pole With 3 Pp, 415 V , 32 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 415 V , 32 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1 Pole With 1 Pp, 415 V , 63 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , Astronomical Timer For Street Light Control, 3 Phase, 18 Kw/43 A Each Phase, Ip 66, Manually Settable Timer With 12 Programmes Spreaded Over A Year As Defined Programme, 260 Volt +/- 5 Volt Over Voltage Protection Per Phase, 160 Volt +/- 5 Volt Under Voltage Protection Per Phase, Operating Temperature Range -10 To +50 Deg C, /=60 Seconds On/Off Timing Accuracy , Embossing Punch Die Tool For Dt Coding (A-Z And 0-9) , Battery Operated Engraving Machine , Hand Operated Oil Pump/Barrel Pump , Manilla Rope - 25 Mm , Nylon Rope- 20 Mm , 11Kv Pilfer Resistant Metering Cubicle For 3Phase 4 Wire Metering System Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Panel Having Two Compartments Upper Meter Compartment And Lower Ct/Pt Compartment. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Sufrace, Dust, Weather And Vermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangments. The Metering Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening The Lv Chamber Door. , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 2.5 /5 For 25Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 5/5 For 63Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 7.5/5 For 100Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 15/5 For 200Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 20/5 For 250Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 25/5 For 400 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 50/5 For 630 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 75/5 For 1 Mva Dt , 11Kv/ 110 V, Three Phase Epoxy Resin Cast Pt With Rated Burden 15Va Per Phase And Accuracy Class 0.5 Or Better And Conforming To Is:3156 (Part-I&Ii) Amended Upto Date With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And Withstand Separate Source 23Kv providing fixing For One Minute. , 3Ph, 3 Wire Ht Ct/Pt Operated Fully Static Smart Tri-Vector Energymeters Dlms Compliantcategory C With Rs232 Port For Modem Compatibility. 11Kv/110V, Ph-Ph (3P,3W) Metersfor Measurement Of Different Electrical Parameters Including Active Energy (Kwh/ Mwh), Reactive Energy (Kvarh/Mvarh), Apparent Energy (Kvah/ Mvah) Etc. (Make L&T, Secure,Abb) , Led String Light 15 Mtr Long Of Different Colours (Saffron/White/Green) With Controller. , 4 Socket Extension Boards With Each Compatible Sockets Of 16 annual periodical maintenance And 5 Mtr Long Cable And Plug Along Surge Protector And On/Off Controller.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
27.
Housing Urban and Rular Development #11093464 Technical Bid
Tender for Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. 120 Sqmm Size , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. 630 Sqmm Size , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentiond As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 12900 Lpm X 30.00 M Head (For Prop. Mps) , Di Pipe (2025): Supply Of Ductile Iron (Di) Isi Marked K9 (Grade S And S Pipes As Per Is:8329-2000 (Amended Up To Date), With Internal Cement Mortar Lining For Potable Water With Rubber Ring (Epdm/Sbr) Joint As Per Is:5382-1985 (Excluding Special Accessories) Complete Including All Material, Labor, Hydraulic Tsting And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. (Not Part Of Dnit) 500 Mm I/D (Including 3% Storage Charges) , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Supply , Erection, Jointing And Commissioning Of 10 Sqmm Isi Marked Alluminium Cable In Trenches Under Ground For Campus Lightening Including All Labour Jointing Material Complete In All Respect. Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Repects. Provision For Suitable Size Switches Boards Along With Switches Including All Material And Labour Complete In All Respect. , Panel Boards For Motors: Supply, Erection, Testing And Commissioning Of Wall Mounted Electrical Lt Panel Board, Fabricated From 16 Swg Crca Sheet Duly Stouten With Suitable Angle Iron Frame Work And Completely Powder Coated Of Suitable Size Deep Having Following Items For 1 Non Clog Submersible Pumping A) Main Switch Suitable Ampere 1 No. (Landt Siemens, Abb) B) Ct 100/3 = 1 Nos. (Ae/ Kappa/ Landt) C) Digital Multi Function Meter = 1 No. D) Spp = 1 No. Of Approved Make E) Motor Starter, Star Delta 1 No (Landt Siemens, Abb) F) Vss 1 No. And Ass 1 Nos. Of Approved Make. G) Capacitor Kvar As Per Site Requirement = 1 No. H) Indicating Lamp = One Set I) Change Over Switch Of Suitable annual periodical maintenance = 1 No. (Each) 9200 Lpm X 25 Mtr. Head (For Ips Matindu Road) , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (50 Sqmm Size) , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Credit Of Dismantled Reinforcement. (The Amount Will Be Deducted From The Total Amount Of All The Other Ns Items) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 7
29.
Agriculture #11076833 AOC
Tender for Annual Plan 2025-26 Development Of Agriculture Sector In Kuttanad Replacement Of Petti-Para With Axial Flow Pumpset For De-Watering Kuttanad Paddy Fields Of Alappuzha, Kottayam And Pathanamthitta Districts , Supply Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Of Alappuzha, Kottayam And Pathanamthitta District With The Specifications Listed Below: Suitable For Handling Saline And Silty Water With Rpm 1000 (Syn) Or Less. The Material Of Construction Of Flange, Suction Bell, Bowl, Shroud Shall Be Ci With 2% Nickel, Impeller, Shaft, Shaft Sleeve, Fastener And Suction Pipe Shall Be Of Ss 304. Delivery Pipe Should Be In Ss 304 With Minimum Thickness 6 Mm And Of Suitable Length (Varies From 4 To10 M) Or As Per Site Condition. The Prime Mover Of The Pump Is To Be 3 Phase Tefc Squirrel Cage Induction Motor Of Reputed Make Operating At 415V +/- 10%, 50 Hz +/- 5% Connection With F Class Insulation, Control Panel Must Have Dust And Vermin Proof Vertical Mounted Cubical Type Panel Board Of Reputed Make With Fcma Soft Starter Of Reputed Make, Mccb Including Phase Failure Protection, Surge Protection Device, Dry Run Protection, Overload Over Current Protection, Thermal Over Load Protection Relay, Earth Fault Relay, Voltmeter, Ammeter, Fault Indication Start And Stop Switches And Power Factor Correction Capacitor Etc. Wiring And Earthing Should Be As Per Regulations Of Kseb And Electrical Inspectorate. Separate Cubical Type Energy Meter Panel With Ct Metering Provision Including 4 Pole Fn Type Isolator, Rccb , Hrc Fuses And Carrier. Suitable Size Copper Cable For Connection From Electric Post To Meter Box And Meter Panel To Motor Control Panel Etc. Should Be Fitted At Site, With Proper Earthing. Cable Termination Should Be As Per The Regulations And Specifications Of Kseb And Electrical Inspectorate Standards. Screen With 6Mm Gi Welded Mesh With 50Mm X 50Mm Opening Size (About 20 Sq.M Area) Framed In Gi A
Contract Date: May 13, 2026 Contract Value : 1.27 Crore
Government Departments No of Bidders 3
30.
Drinking Water Supply and Sanitation #11048011 Technical Bid
Tender For Supply, Installation, Testing & Commissioning Of Pump Set With All E electrical and mechanical Equipment For Online Booster Pumping Station At Meethapur Chowk Under Badarpur Constituency Ac-53. , Supply Of Horizontal Split Casing Single Stage Pump Having Flanged Suction & Delivery And Suitable To Handle Potable Water. The Pump Should Have Following Duties:- Discharge Capacity :- 115 -130 M3/Hr Duty Head :- 40 Mtrs. Speed :- 1450 Rpm Material Of Construction Casing : Ci Shaft : Stainless Steel En-8 Impeller : Ci Sleeve : Ss-410 Wear Ring : Ci Make: Mather & Plate / Kirloskar/Jyoti/Beacon Weir/Djb Approved , Supply Of 30 Hp 1500 Rpm (Syn) Squirrel Cage Induction Motor Suitable To Operate On 400±10% Volt, 3Ph , 50Hz , Horizontal Foot Mounted Confirming To Iec:60034-1. Sor(E&M)-2024 Item Code 3.2.18. Make:- Abb/Kirloskar/Jyoti/Crompton/Djb Approved , Supply Of Ms Base Frame, Flexible Tyre Coupling, Coupling Guard Suitable For Above Pump Sets. , Providing & Fixing Lt Starter Panel Board Of Size 1400X1200x350 Mm Made Out Of 14 Swg Crca Sheet Floor Mounted Type And Suitable To Fix Below Mentioned Items, I/C Provision For Cable Entry & Base Frame Made Out Of Ms Channel. The Panel Should Be Duly Painted With Vermin Proof Paint And Completely Wired With Suitable Size Copper Wire. Incomer Consisting Of Following:- 1 No. Automatic Phase Sequence Correcting Power Switch Circuit With A Provision For Manual Operation : 250 Amps 4P, 415 Vac 50 Hz Make:-L&T/Abb/Schneider/Siemens/Socomec/Hp ,1 No. Mccb Tp 250 Amps 36 Ka Thermal Magnetic With Adjustable Trip Setting For Overload And Short Circuit Protection Make:-Siemens/L&T/Abb/Schneider , 1 No. Voltmeter With Vss 0-500 Vac Digital Type 96Mm X 96Mm Make:- Rishabh/Ae/L&T/Schneider , 1 No. Ammeter With Ass 0 - 250 Amps Digital Type 96Mm X 96Mm Make:- Rishabh/Ae/L&T/Schneider , 1 No. Energy Meter (Kwhr) Digital Type Ct Operated Class 0.5 Make:- Rishabh/Ae/L&T/Schneider , 3 Nos. Ct 250 / 5 Amps Class : 0.5 For Metering Make:- Kappa / Ae , 1 No. Ct 250 / 5 Amps For Power Factor Control Make:- Kappa / Ae , 3 Set R Y B Indication Make:- Teknic / L&T / Abb / Schneider , 3 Set On / Off / Trip Indication Make:-Teknic / L&T / Abb / Schneider , 1 No. Cbct Based Earth Fault Protection System To Trip The Mccb In Case Of Earth Fault, Make:- Prok Devices / Elmeasure / Siemens / Schneider / Abb / L&T , 1. No Earth Fault Trip Indication Suitable For Operation Of 2P/Set Make:- Teknic / L&T / Abb / Schneider. Control Consisting Of Following:- 1 No. Current Transformer 415 Vac / 220 Vac 500 Va Make:- Logicstat / Eq ,2 Nos. Control Mcb Dp 10 Amps Make:- Siemens/L&T/Abb/Schneider , 1 No. Control On Indication Make:-Teknic / L&T / Abb / Schneider. Starter Section Consisting Of Following:- 30 Hp Star / Delta Starter (1W + 1S) With Following Total Material For Both 2 Nos. Mccb Tp 36 Ka Motor Duty Suitable For 30 Hp Make:-Siemens/L&T/Abb/Schneider, 4 Nos. Contactor Tp 95 Amps Ac3 Duty 220 Vac Make:- Siemens/L&T/Abb/Schneider , 2 Nos. Contactor Tp 63 Amps Ac3 Duty 220 Vac Make:- Siemens/L&T/Abb/Schneider, 2 Nos. Thermal Over Load Relay 45-63 Amps Make:- Siemens/L&T/Abb/Schneider , 2 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 4 Set Start / Stop Pb Make:- Teknic / L&T / Abb / Schneider , 4 Set On / Off / Trip Indication Make:- Teknic / L&T / Abb / Schneider , 4 Nos. Star / Delta Timer Make:- Siemens/L&T/Abb/Schneider. Dol Starter Up To 5 H.P For 2 Nos. P/Set. Having 2 No. Mcb Tp 16 Amps Make:- Siemens/L&T/Abb/Schneider , 1 No. Contactor 16 Amps Tp 230 Vac Make:- Siemens/L&T/Abb/Schneider , 1 No. Overload Relay 2.8 - 4 Amps Make:- Siemens/L&T/Abb/Schneider , 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 2 Set Start / Stop Pb Make:- Siemens/L&T/Abb/Schneider , 2 Set On / Off / Trip Indication Make:- Teknic / L&T / Abb / Schneider. Lighting Section Having 4 Nos. 10 Amps Sp Mcb For Lights/Fans Etcmake:-Siemens/L&T/Abb/Schneider. Power Factor Section Of 50 Kvar Apfc System Having 1 No. Mccb Tp 160 Amps Thermal Magnetic 36 Ka For Apfc Section Isolation Make:- Siemens/L&T/Abb/Schneider , 1 No. Microprocessor Based Apfc Relay 6 Steps Make:- Epcos / L&T / Abb / Beluk , 4 Nos. Capacitor Heavy Duty Mpp 10 Kvar 415 Vac Make:- Epcos / L&T / Abb / Beluk , 4 Nos. Capacitor Duty Contactor Suitable For 20 Kvar Or Higher 220 Vac Make:- Siemens/L&T/Abb/Schneider , 4 Nos. Mcb Tp 40 Amps Make:- Siemens/L&T/Abb/Schneider , 4 Nos. Auto / Manual Selector Switch With Led Indication Make:- Teknic / L&T / Abb / Schneider , 8 Set Start / Stop Pb In Manual Mode Make:- Teknic / L&T / Abb / Schneider , 2 Nos. Capacitor Heavy Duty Mpp 5 Kvar 415 Vac Make:- Epcos / L&T / Abb / Beluk , 2 Nos. Capacitor Duty Contactor Suitable For 10 Kvar Or Higher 220 Vac Make:- Siemens/L&T/Abb/Schneider , 2 Nos. Mcb Tp 20 Amps Make:- Siemens/L&T/Abb/Schneider , 2 Nos. Auto / Manual Selector Switch With Led Indication Make:- Teknic / L&T / Abb / Schneider , 4 Set Start / Stop Pb In Manual Mode Make:- Teknic / L&T / Abb / Schneider. Miscellaneous Material Having 1 No. Bus Bar With Heak Shrinkable Sleeves Make:- Hindalco / Ec Grade With Certificate , 1 No. Powder Coated Panel Enclosure With Accessories Make:- Djb Approved , 1 No. Control Wire. Make:- Djb Approved , 1 No. Power Wire. Make:- Djb Approved , 1 No. Dismantling Of Existing Panel, 1 No. Delivery And Installation Of New Panel, 1 No. Lugs / Glands As Required For Connections. , Supply Of Pvc Insulated Pvc Sheathed Armored Aluminum Conductor Power Cable 1.1 Kv As Per Is-1554 ( Part-I) Of Following Sizes. 3½ Core X 120 Mm². , Supply Of Pvc Insulated Un Armored Single Core Flexible Copper Cable For Working Voltage Upto 1.1 Kv As Per Is:694/2010 Of Size 35 Mm2.. Make :Grandley / Gloster/Djb Approved , Supply Of Ci Sluice Valves Non Rising With Ss Spindle Isi Pn 1.0 Is 14846 Flanged End Of Following Sizes (A) 200 Mm Dia. , (B) 150 Mm Dia. , Supply Of Ci Non Return Valve Without Bypass Swing Type Is:5312 Flange End Of 150 Mm Dia. Make:- Kirloskar/Ivc/Djb Approved , Pipes &Special S/O M.S. Pipe Of Dia.200 Mm. , S/O M.S Flange Of Dia. 200 Mm. , S/O M.S. D.F.90° Bend Of 200 Mm Dia. , S/O M.S. D.F.90° Bend Of 150 Mm Dia. , S/O M.S. Pipe Of 150 Mm Dia. , S/O M.S Flange Of Dia. 150 Mm. , S/O Ms All Flanged 200 X 200 X 200 Mm Dia. Tee. , S/O M.S All Flanged 150X150x150mm Dia. Tee. , Welding And Fitting Of Above Item As Per Site Requirement. , Supply Of Vacuum Pump Set Dv-40 In Standard Construction With Bronze Impeller, Stainless Steel Shaft, Ci Body, Complete With Base Frame, Coupling, Coupling Guard Etc.Make:- Kirloskar/Djb Approved. Supply Of Squirrel Cage Induction Motor Tefc, 5 Hp 1500 Rpm, Suitable To Operate 400±10% Volts, 3 Phase 50Hz Ac Supply.Make: Kirloskar / Jyoti / Crompton/Djb Approved. , Providing &Fixing Of 40 Mm Dia G.I. Medium Class Pipe , Pipe Fittings Like Socket ,Elbow ,Tee ,Union , X-Nipple , Gm Gate Valve 40 Mm Dia( 4 Nos.) 15 Mm Dia( 1 No) With Required Fittings And Base Frame , 500 Ltr Pvc Tank To Be Placed On Roof.Make:-Pipe : Jindal / Isi Marked ,Fittings:- R- Brand / Isi Marked ,Gate Valve:- Sant/Leader/Isi Marked. , Supply Of 19 Mm Thick High Voltage Insulation Mats, Size 1M X 2M. , Supply Of Pressure Gauge 150 Mm Dia. 0-100 Psi , Gi Pipe Fitting , Stock Cock , Copper Tube , Wooden Board On The Suction & Delivery Of Each Pump. One Complete Set Of 250 Mm Dia. Pressure Gauge 0-100 Psi On Main Header With All Fittings Etc. 150 Mm Dia. Make:- H Guru / Fiebig , Supply Of Fire Extinguisher Powder Type 4.5 Kg Capacity. Make:- Bharat / Nithi / Isi Mark , Supply Of Fire Bucket 9 Liter Capacity With Stand Of 6 Nos. Bucket. Make:- Spink/Arihant/Djb Approved , Supply Of Nut Bolt As Per Site Requirement. , Supply Of Rubber Sheet For Packing As Per Site Requirement. , Supply Of Change Over Switch 320 Annual Periodical Maintenance , 4 Pole . 415 Volts ,Confirms To Iec: 60974-Iii/Is : 13947-Ii Make:- Havells/Abb/ Djb Approved , Fabrication / Supply& Fixing Of Retro Reflective Sign Board Made Out Of 40 X 40 X 6Mm Ms Angle Iron Frame & 2 Mm Thick Ms Sheet & 50 Mm Dia. Gi Pipe For Supporting The Board. The Size Of Board 4 Mtr. X 1Mtr. Including Grouting Of Board In Proper Way. The Board Shall Be Duly Painted & Matter To Be Written As Per The Direction Of Engineer In Charge. , Providing / Fixing Of Ismb 300 X 140 Mm Along The Length (7 Mtrs.) Of Pump House With Isi Marked Triple Spur Geared Chain Pulley Block With Greed 80 Alloy Steel Load Chain Tested To 50% Overload Confirming To Is- 3832 - 9087 Of 2 Ton Capacity With Overhead Monorail Travelling Trolley With 5 Mtr Chain Mounted On Ismb 300 X 140 Approx. 7 Mtr Long. Sor(E&M)-2024 Item Code-7.27.10. Make:-Indef / Morris / Avon / Hercules / Reva /Djb Approved , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories & Providing Masonry Enclosure With Cover Plate Having Locking Arrangement & Watering Pipe Of 2.7 Mtr Long Etc With Charcoal / Coke & Salt As Required. , Making Of Reinforced Cement Concrete Foundation For 2 Nos. P/Sets With All Material Like Steel, Cement, Concrete, Foundation Bolt& All Other Related Civil Work Required To Complete The Pump House , Installation, Testing & Commissioning Of All Above E&M Equipment. It Includes Laying Of Pipe Line, Cable As Per The Instruction Of Engineer In Charge. Itjob Also Includes Cost Of Cartage, Painting, Watch & Ward Of The Materials At Site And Minor Items/Jobs Required (Reducer, Socket Etc.) For Pump House Operational &Commissioning The Same Up To The Satisfaction Of Engineer In Charge With One Year Guarantee.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
33.
Drinking Water Supply and Sanitation #10896284 Price Bid
Tender for N.S. Item , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 2700 Lpm X 50.00 M (For B/Stn. No.12) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6900 Lpm X 45.00 M (For B/Stn. No.14) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 4100 Lpm X 45.00 M (For B/Stn. No.16) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 3500 Lpm X 45.00 M (For B/Stn. No.25) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (10 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (50 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (70 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (95 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (120 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (150 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (185 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (240 Sqmm Size) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.12) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 115 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.14) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 70 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.16) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.18) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.19) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.20) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 60 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.25) , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. (35 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (70 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (95 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (150 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (240 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (300 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (400 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (500 Sqmm Size) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 35 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.22) , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 2800 Lpm X 50.00 M (At Mbs For Zone -2) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 40 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For Zone-1) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 55 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For Zone-2) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6900 Lpm X 50.00 M (For B/Stn. No.10) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 130 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.10) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 9500 Lpm X 45.00 M (For B/Stn. No.13) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 160 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.13) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5900 Lpm X 45.00 M (For B/Stn. No.17) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 100 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.17) , Providing And Fixing Of Ci Sluice Valves Conform To Is1 4846 / Din 3352,With Length Over Flanges As Per Pdoralt1ofis14846 Corresponding To Bsen - 558/Iso5752 Basic Series 3 And15 Respectively Including Labour, Material, Joints. Make:Ivc / Vag / Kirloskar Complete In All Respect As Per Specifications Mentioned In Dnit (700 Mm I/D) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 10 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.15) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 120 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At B/Stn. No.13 For Existing Pumping Machinery) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5100 Lpm X 50.00 M (At Mbs-1 Zone) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 95 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs-1 Zone) , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 100 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 150 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 200 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 250 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 400 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 450 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 500 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 600 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 700 Mm Nominal Diameter , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8500 Lpm X 35.00 M (At Mbs-1 For B/Stn.) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 112.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs-1 For B/Stn.) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5500 Lpm X 30.00 M (At Mbs For B/Stn.) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 62.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For B/Stn.) , Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Respects. (Led= 5 No.) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6000 Lpm X 50.00 M (For B/Stn. No.9) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 115 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.9) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 4600 Lpm X 45.00 M (For B/Stn. No.23) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 77.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.23) , Less Credit For Old Good Bricks 20.77 X 60% = 12.46 @ 480 Brick Per Cum = 5981 , Less Credit For Old Bricks Bats @ 40% ( Cum ) Total 20.77 X 40% = 8.31 , Less Credit For Ms Railing @ 40% ( Cum ) Total 11 X 50 = 550 Kg , Providing And Fixing Of 15 Mm Nominal Diameter Water Meter As Per Is 779:1994 Inferential Type Dry Dial, Mechanical Driven, Non Megnatic Drive, Straight Reading Cyclometer Type, 7-Inline Consequent Digits With One Centre Point For Easy Reading Complete In All Respect. , (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). (1 For B/Stn. No.9 , 1 For B/Stn. No.10 , 1 For B/Stn. No.11 , 1 For B/Stn. No.12 , 1 For B/Stn. No.14 , 1 For B/Stn. No.16 , 1 For B/Stn. No.17 , 1 For B/Stn. No.21 , 1 For B/Stn. No.22 , 1 For B/Stn. No.23 , 1 For B/Stn. No.25 , 1 For Mbs-1 , 1 For Mbs-2) , Operation And Maintenance For Complete Scope Of Work Mentioned In Dnit (Disinfection Material Will Be Supplied By Phed) As Per Schedule-Iv For A Period Of 5 Year After 12 MonthS During Defect Liability Period And 3 Months Trial Run Period Will Be Charged To The annual maintenance Estimate Complete In All Respect As Per Approved Nit. (I) Operation And Maintenance Defect Liability Period (Operation Only) After 3 Months Trial Run Period. , (Ii) Operation And Maintenance During 1St Year After Defect Liability Period. , (Iii) Operation And Maintenance During 2Nd Year. , (Iv) Operation And Maintenance During 3Rd Year. , (V) Operation And Maintenance During 4Th Year. , (V) Operation And Maintenance During 5Th Year. , Item Description , Hsr Item
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 12.02 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 2.42 Lakh
Government Departments No of Bidders 8
37.
Agriculture #10835218 AOC
Tender For Nabard Ridf Xxx - Replacement Of Petty Para With Energy Efficient Pump-Sets For Dewatering Paddy Fields In Alappuzha, Kottayam And Pathanamthitta Districts Of Kerala - Supply, installation, testing, trial run and commissioning of Submersible Vertical Axial Flow Pump-set for various padashekarams of Alappuzha, Kottayam and Pathanamthitta districts with the specifications listed below: Suitable for handling silty, fresh and salty water with rpm 1000 (Syn) or less.The material of construction of the casing, suction bell shall be CIFG 260 with 2% NICL, impeller CF8M (SS) with SS 316 shaft, vertical submerged column pipe should be of SS 304 and horizontal delivery pipe (varies from 4 to 10 m length as per site conditions) of SS 304 with 6 mm minimum thickness. A metallic non-corrosive strainer of mesh size not more than 50 mm x 50 mm should be fitted at mouth of suction column. Any hanging portion of the delivery pipe should be supported with suitable metallic supporting frames or RCC pillars of suitable size as per site requirements. The prime mover for the pump should be 3 phase, totally Enclosed Water- Cooled squirrel cage submersible induction motor of reputed make operating at 415V+/- 10%, 50Hz+/-5% connection with “F” class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board with FCMA soft starter of reputed make , MCCB including phase failure protection, surge protection devise, dry run protection, overload over current protection, thermal over load protection relay, earth fault relay, voltmeter, ammeter, fault indication start and stop switches, power factor correction capacitor etc. Wiring and earthing should be as per regulation and specification of KSEB and electrical inspectorate. Separate cubical type energy meter panel of reputed make with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc should be fitted at site, with proper earthing. Cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. A screen with 6 mm GI welded mesh with 50 mm x 50 mm opening size, (about 20 sq.m area) framed in GI angles and GI tubes shall be fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc 2 Duty point head (m) : 3Minimum discharge at Duty point head (lps):354Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):20 3 Duty point head (m) : 3Minimum discharge at Duty point head (lps):532Working head range m:1to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):30 4 Duty point head (m) : 3Minimum discharge at Duty point head (lps):709Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):40 5 Duty point head (m) : 3Minimum discharge at Duty point head (lps):886Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):50 6 Duty point head (m) : 3Minimum discharge at Duty point head (lps):1064Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):60 7 Duty point head (m) : 3Minimum discharge at Duty point head (lps):1241Working head range m:1 to 4.5Minimum Overall efficiency (%) at duty point head:70Available connected load (hp):70
Contract Date: May 06, 2026 Contract Value : 7.73 Crore
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
40.
Housing Urban and Rular Development #10778154 Price Bid
Tender For Construction Of 33/11 Kv Sub-Station In Sector 146, Noida. - S/E of Terminal Gantry Structure of R.S. Joist - 175x85 mm. 19.5 Kg/Mtr. 6.1 Mtr. above the ground and 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. with 2 nos channel 175x85 mm suitable for Disc & Pin Insulator Including earth excavation back filling making plinth of required height and with required fabrication as per drawing. complete in all respects as per direction of E/I.(AOR) 2 S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama/UPPCL approved. as per direction of the E/I. (AOR) 3 Supply, Errection, Testing & Commissioningof 33 KV Outdoor VCB with required str, 1250A, 1500MVA, 25KA, Motorized 750MVA/1250Amp/ with transformer control & relay pannel includingCT, PT with structure. complete in all respectsMake: Crompton/ABB/Schneider as per specification and direction of E/I. (AOR) 4 S/E of Busbar Gantry Structure of 105 Lbs/Yard Rail pole 6.50 M long 5.2 Mtr. above the ground level and 1.30 Mtr. Below in 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. With M.S. angle 100x100x8mm (12.1Kg/M) mm suitable for Disc insulator including earth excavation, back filling, making plinth of required height and with required fabrication as per drawing complete in all respects as per direction of E/I.(AOR) 5 S/E of 33 KV, 1250A Bus Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. Thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/M and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects Make: Jaipuria/Rama as per direction of the E/I. (AOR) 6 S/F of 33 KV fuse set out door type of Relco/Rama make complete including structure as per drawing. Complete in all respects.(AOR) 7 S/E of 33 KV Lightning Arrestors with Structure made of M.S. Channel 125x65 mm. 13.1Kg/M top of M.S. Angle 50x50x6 mm. 4.5 Kg/M Lightning Arrestors/Post Insulator are to be mounted on M.S. Plate of 200x150x8 mm. Height of structure is to be 3.5 Mtr. above ground and 1 Mtr. below ground on a 75 mm. thick cement concrete pad with 1:4:8 cement concrete foundation, making plinth of required height including all fabrication as per drawing complete in all respectsMake: Elpro/Oblum/W/Sas per direction of E/I. (AOR) 8 Supply & fixing of 33 KV with 11KV 4 Nos SetB&S type strain Disc insulators 120KN E&M strength. as per drawing complete in all respects Make : Jaishree/BHEL/WS/RR as per direction of E/I.(AOR) 9 Supply & fixing of 33 KV tension fitting suitable for panther conductor and 120KN E&M 11KV disc insulator set of 4 complete in all respects as per direction of E/I. (AOR) 10 Construction of 33 KVtransformer plinth as per drawing. with all material, labour and T&P etc. required for proper completion of the work as per specifications of UPPCLas per direction of E/I.(AOR) 11 Providing and fixing of G.I Chain link fabric fencing of required width size 50x50mm including strenthening with 2mm dia wire or nuts,bolts and washers as required complete as per the direction of the Enginner-in- charge.made of G.I wire of dia 4mm PVC Coated to achive outer dia not less 5mm in required colour and shade.complete in all respect as per ditection of E/I(AOR). 12 Construction of boundary wall in brick work with cement mortar 1:6 (1 Cement : 6 Coarse Sand) for chain link including plaster in cement mortar 1:4 (1 Cement : 4 Coarse Sand) and finishing with water proofing cement paint complete as per attached drawing & complete in all respects as per direction of E/I.(AOR) 13 S/Fixing of 33 KV Post insulator 2x22KV of approved quality and make with all necessary material required for proper fixing including structure made of 125x65mm MS Channel (2.5Mtr above ground of 1 mtr below with ground with grouting 1:3:6 cement concrete including all labour, material, T&P etc. required for proper completion of the work. as per drawing. complete in all respectsMake: Jai shree / BHELas per direction of E/I (AOR) 14 1 nos1250A, VCB of (350MVA) 18.4 KA reputring capacity at 11 KV rated,totally enclosed, air insulated metal card housing floor mounting horizontal isolotion vermin proof fully interlock horizontal draqout type having isolation features and control devices complete with following. (AOR) 15 8 nos single phase double core current transformer 300/5.5/5 Amp epoxy cast resin isulated class of isulation E as per SLD. 16 core 1-15 VAburden class 1.0 for meeting 17 core 1-15 VAburden class 5P10 for protection 18 one no.numerical microprossor based three phase over current (IDMT element )with earth fault relay with instantaeous elements. 19 1 no Anti Pumping device 20 1 no circuit breaker control switch for electrical (T/N/C) 21 1 no limit switch for test & service 22 1 no Ammeter (0-3000Amp & 0-5-Amp) with selector switch (96mm Square. 23 1 no Electronic type digital energy analyser having 30 Days memory and parameters of KW-KWH,Power factor, frequency etcsuitablefor BMS compatible with all accessories. 24 1 no tri vector meter 25 1 set of following indicatinglamps 26 Red,Yellow,& Blue for Phase indication 27 Amber for trip indication 28 Redon Green off 29 Spring charge indication 30 Auto trip indication 31 1 No Hooter with hooter acceptance and reset push button 32 1 No master trip relay (Eletromechanical type) 33 1 set of fuses ferrules wiring etc as required 34 Note: All Spare contact of breakers or any other equipment inside the breaker shall bewired upto the outgoing terminal strip with appropriate terrules/coding . The terminal strip rating shall be suitable for coneccting two wires of 2.5 sqmm subjected to providing minimum size suitable for 4/6 sqmm. (Make- ABB, Crompton, Schnieder, Seimens) 35 11KV H.T Panel describe as above 36 Construction of control cable trench of required size 0.30x0.45 Mtr. bricks class designated-100 work including plastering etc. and covered with R.C.C. Slab (0.50x0.60 M) size complete with all material, labour and T&P etc. required for proper completion of work. complete in all respects. As per direction of E/I.(AOR) 37 S/Filling of 20 mm. stone grit in yard of size26x36mtr75 mm. thick complete in all respects. (AOR) 38 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 39 Supply & laying of earth mat in the switch yard of the Sub-Station for all Electrical Equipments and structure by laying of M.S. Round bar of 32 mm. dia. in 750 mm. deep trenches and earth electrode 3.0 M. long of M.S. round bar 32 mm. dia 0.5 M below ground level. The work include welding/bending/flooring of M.S. round bar and connection all steel structure in switch yard with earth mat by means of M.S. Strip of size 50x6 mm. including all labour, materials, T&P etc. required for proper completion of the work as per details specification of UPPCL Complete in all respects as per direction of E/I. (AOR) 40 Painting of (Complete sub-station) Terminal Gantry, Lighting arrestor, Busbar Gantry, Line Isolator & Bus Isolator Structures, Post insulator, Fencing, Poles and other structure complete with two coats of Al. paint over red oxide. (AOR) 41 S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I.(AOR) 42 Supply and laying of Control Cable for metering as per direction of E/I. (Gloster/Grandley/Havells/ Polycab/ Diacab make) (AOR) 43 (a) 2.5 Sq. mm. 2 Core Copper 44 (b) 2.5 Sq. mm. 4 Core Copper 45 (c) 2.5 Sq. mm. 10 Core Copper 46 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-48 47 S/E of 125x65 mm. MS Channel (13.10 Kg/M) 1.5 M long fixing in control room for OCB/VCB pannel complete in all respects as per direction of E/I.(AOR) 48 Supply/Fixing of MS ladder of size 5 mtr long and 0.4m width with MS angle 40x40x6mm incl painting etc . complete in all respect as per direction of E/I.(AOR) 49 Supply, Installation, Commissioning & Testing of Battery charger 24V 24V/40Amp float cum Boost battery charger with dropping diodes suitable for I/P 230V±10%, 1 Phase, 50Hz Type FCBC as per PVVNL Specification, maximum continuous output ratings (outpur voltage in float mode 25.80 Volts and in Boost mode upto 33.0 Volts), output current 40A, Plus trickle charging currentof battery floatmode 20A(Max), Boostmode 20A Load terminal, 20A, Battery terminal 20A, Starting rate 10A upto 2.35 V per cell, Finishing rate 10 Aupto 2.75 V Per cell, Output ripple 1% PP at full load and 25.8V DC, output regulation (floatmode) ±1%for ±10% supply voltage fluctuation and ±10% to 100% load variation, Automatic/manual mode of operation, Automatic and manual terminal charging, control configuration 1-phasefull wave controlled, thyristor bridge feed through 1-phase transformer and controlled by constant current/protential controller with load liminting feature and integrated non compartmentalized DCDB with 01 No 60A MCCB incomer, 5 Nos 16AMCB, sheet thickness 2mm, protection as per detail specification enclosed. 50 IS: 13947) IP-42/ maximum Permissible input volage ±10% of 230V AC, Electronic protection with auto reset against short circuit and overload ,DC over voltage short circuit at charger output terminals, thyristor by fuseing with protection against over charging, efficiency of rectified >65% at rated load, Power factor 0.7 lag at D.C. Current 230V Input with ANC cooling typeand Class F type insulation.For Battery : 240V/200AH Tubular type Battery Bank consisting 12 Cells of each 2V/200 AH dry & uncharged along with wooden stand & accessories (AOR) 51 S/Installation, testing & commissioning of out door type 10 MVA with on load tap changer Power Transformer as per ISI specificationincluding loading, unloading, local carriage & erection of the same on existing plinth & making all necessary connection etc. Complete in all respects Make: Crompton/ Alstom/BHEL/ABB/Schneider as per direction of E/I. (E-12) or approved GTP from UPPCL/PVVNL cable termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side.cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.On load tap changer +/- 7.5@ 2.5% Bi directional roller, Conservator with drain valve, Earthing terminals, Double diaphragm explosion vent, Radiator with top & bottom shut off valve, First filling of oil including make up fill, Silica gel breather with oil seal, Rating and diagram plate, Air Release plug, Buchholz relay with shut off valve, Winding temperature indicator (WTI), Oil Temperature indicator (OTI), Megenatic oil level guage, Pressure relief device, Marshalling box .Aproved By CEO. (AOR) 52 S/Laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 75 cm. below ground level over a cushion of 75mm. Below ground level over a cushion of 75mm. thick snad alround and protected with burnt bicks on sides and on top. on surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.S. No. 501 (Gloster/Grandly/Polycab/ Havells/Diacab. make) 53 a) 50 Sq.mm. 3½ Core 54 b) 25 Sq.mm. 3½ Core 55 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. P.S. No. 1131 56 Supply and fixing of Lugs(socket) forCable P.S. No. 504 57 i) 25 Sq.mm. 58 ii) 50 Sq.mm. 59 iii) 120 Sq.mm. 60 iv) 185 Sq.mm. 61 supply and burying earth electrode for lighting conductor of 600mmx600mmx6.0mm G.I. Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. Pipe for watering funnel, 30cm square C.I frame with hinged cover masonry housing alternate layrs of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects.P.S. No. 706 62 S/F of brass nickle plated compression gland for PVC isulated & armoured served sheathed, underground cable incl. rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of E/I P.S. No 503 63 (a) Size 25 mmx 3.5 core 64 (b) Size 16 mmx4 core 65 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 66 S/B of 40 mm dia x4.5 meters long GI pipe vertically of earthing having 12 mm dia. Holes spaced 75 mm apart drilled up to 2 meter from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in GI pipe up to appron) and from appron to switch board (The cost of GI wire and pipe will be extra) upto switch board, 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layes of charcoal / coke and salt at least 150mm thick alround etc. as per directions of engineer-in-charge complete in all respects as per drawing as per PS No. 701 67 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing ead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (B) 68 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 69 S/E of overhead line with ACSR(Painther/Dog) Conductor on pole/service bracket including binding etc. complete in all respects PS No 627 70 S/F of fire bucket, round bottom made of GI sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket, chained & locked initially filled with fine river sand, water as per direction of E/I. P.S. No. 1133 71 S/F of shock treatment chart (Prescribed under I.E. Rules) duly framed with glass & supported from back with hard board or soft board with supply of all material labour and T&P for proper completion of work. P.S. No. 1134 72 S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality. P.S. No. 1136 73 Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 74 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :Make : Raychem/ Denson/ :DSR 2018 75 120 Sq.mm.I.No. 10.5.2 76 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :Make : Raychem/ Denson. 77 120 Sq.mm. UPERC Pg-27 78 185 Sq.mm UPERC Pg-29 79 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.DSR-2018/Item No. 14.13.2 80 80mm dia 14.13.2 81 100mm dia 14.13.3 82 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 83 Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR-2018/I.No. 13.23 84 Supply and fixing Clamps, bolts, nuts etc.complete in all respects (DSR-2018/I.No. 2924) 85 Supply of following type high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. Complete in all respects Make: Gloster/ /Universal/ Polycab/ Havells/ Diacab .as per direction of E/I. 86 i) 185 Sq.mm. 3 Core UPREC 2019 P-41 87 ii) 120 Sq.mm. 3 CoreUPREC 2019 P-41 88 S/F of 11 KV pin 12 long with insulator of Jai Shree/HBHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16 89 S/F of 11 KV TPMO Relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC P-48 90 S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : P.M./Kanohar/LD Power/Paramix as per direction of E/I (UPERC 2019) P-51 91 Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 92 BOQ-BSupply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 93 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 94 Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 95 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 96 Supply of 300 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 33 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respectsas per direction of E/I. Make: Gloster/ /Universal/ Polycab/ Havells/ Diacab . (UPERC P-47) 97 S/F of jointing of 300 sq. mm out door type type 33 KV jointing kit heat Shrinkable type for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson. as per direction of E/I. (UPERC P-47) 98 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 99 S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson. As per direction of E/I. (UPERC P-47) 100 S/E of over head line with ACSR Panther Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 101 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) 102 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 103 S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 300 Sqmm 104 Painting of the electric pole with 2 coat of AI paint over red oxide primer complete in all respects As per PS No. 634 105 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 106 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 107 S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 108 Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) 109 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ naranderplast/pioneer make). (AOR) 110 Providing and laying of200mm dia 6mmthickness through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) 111 S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama. as per direction of the E/I. (AOR) 112 Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm 113 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N.7.9/P30) 114 Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required..(DSR Electrical 2018/Item 13.23 Page 50) 115 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation,ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) 116 Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturers specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) 117 Lettering with black japan paint of approved brand and manufacturer (AOR) 118 Providing and laying in position cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.7 P-48 119 Providing and laying in position cement concrete1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.9 P-48 120 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) 121 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) 122 BOQ-CWiring points for light with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire,GP Box piano type switch and ceiling rose/angle/batten holder3mm thick phenolic laminated backelite sheet etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 138C 123 Wiring points for Fan/fresh air fan (light duty exhaust fan) with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire,GP Box piano type switch and ceiling rose3mm thick backelite sheet etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 140C 124 Wiring points for Plug with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and socket etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 141C 125 Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. P.S No. 1405 Cat AAA 126 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. PS No. 1002 Cat A 127 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 128 Supply and fixing of power plug with 15A / 250 V flush type switch and 5 pin 15 A / 250V flush type socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with Bakelite sheet cover 3 mm. thick fixed with brass machine screws and cup washer. P.S. No. 1139 129 Supply and wiring of submain with two number 6 sqmm FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 25mm dia heavy duty (2mm thick) PVC Conduitl with one number 4 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. as per PS No. 217 (C) 130 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS No. 641(Make - Bajaj/ Transrail /Volmont/ NERI) 131 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. P.S. No. 1421 Cat. AAA 132 Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Grandley/Gloster/Havells, Polycab, Diacab. make) P.S 501 133 a. 25 sq. mm 3.5 core 134 b. 35 sq. mm 3.5 core(PS No. 501(k) 135 S/F of sintex type junction box model no. IIGSJB 2817 of size 240x130x110mm with hinges and locking arrangment & MS clamp of 50x6mm flat, complete in all respects including 2 no. G.I pipe 1.5 dia having 1.0 meter length each and chuck nut for cable connection etc. as per direction of E/I. (AOR) 136 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 e (ii) 25 A TPN 137 S/F surface/flush mounting 6 ways TPN distribution board without MCB complete in all respects and as directed at site. PS No.1027 Cat A 138 S/F of hexagonal Round GP fan box with hexagonal side of approx. 80mm in lenth fabricated from 16SWG MS Sheet incorporating 10mm dia M S round bar duly duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all materials, labour, T&P etc. for proper completion of work PS No. 1149 139 S/F of fan regulator dimmer 300/400W ISI mark on the existing switch board including making connection T&P etc. for proper completion of work to the satisfaction of Engineer of work. PS No. 1203 140 S/F of Palm or pin type tin plated copper cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of E/I. (PS No. 504 (e)25 sq.mm 141 f) 35 sq. mm 142 S&F of 63 Amp. 4 pole MCB(10 KA) C Curve as per PS No. 1020 (A) Cat-A 143 Supply and fixing of following size heavy duty industrial type Exhaust fan with louvered shuttersof approved make complete with wire guard mesh, mounting sings frame bracket etc. but without regulator suitable for use on 230/240V 50Hz single phase AC supply and conforming to IS: 2312-1967 with update amended (900 RPM) (Havells single phase Model-300mm)300mm dia (AOR) 144 Supply and Fixing of Ceiling fan 1200 mm dia ISI marked Make-Baja, Crompton, Havells or equivalent make.(AOR) 145 BOQ-DS/F of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of UPERC P-54 146 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 147 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 148 Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 149 Supply of following type high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (Gloster/Universal/Havells, Polycab, Diacab.make)(UPERC 2019 Pg-28) 150 i) 185 Sq.mm. 3 Core E-48 151 Laying of One number PVC insulated and PVC sheathed/ XLPE power cable of 11KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.3.2/P31) Above 120 Sqmm and upto 400 Sqmm 152 S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-29 153 185 Sq.mm. 154 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE-100 grade as per IS code 4984 with excavation at depth of 1.20 Mtr. Below ground level i/c the cost of cutting of pipes for making upto length and making joints complete all respects asper direction of E/I (Crator Poly extrusion/Duraline/Rex/time/narander plast/Poineer make) (AOR) 155 Providing and laying of MS Pipe of 200mm dia 6mmthickness as per IS 3589 grade FE 410 through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) 156 S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS& complete as per the direction and satisfaction ofE/I(Raychem, Denson.Make) UPERC 2019 Pg-29 157 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 158 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. DSR 2018 13.4 159 S/F of 11 KV pin 12 long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC Pg-39 160 S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 185 Sqmm 161 Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 162 Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I. (AOR) 163 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 164 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 165 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N.7.9/P30) 166 S/E of over head line with ACSR Dog Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 167 S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 168 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) 169 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 170 Providing and laying in position cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.7 P-48 171 Providing and laying in position cement concrete1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.9 P-48 172 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) 173 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) 174 Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturers specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) 175 Lettering with black japan paint of approved brand and manufacturer (AOR) 176 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation,ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) 177 Operation of 33/11 KV Sub-Station round the clock in 3 shifts of 8 hours each by a team comprising of one electrician, skilled operator (having minimum qualification of ITI (Electrician grade) and one unskilled helper in each shift for operation of S/S equipments including maintenance of 11 KV incoming and outgoing Switchgear panels, 33 KV Switchgear pannels, battery and battery charger, 33/11 KV Transformer with control pannels, HT/LT Cable/Lines along with all associated equipments installed at 33/11 KV Sub-Station compus, (Contractor may deploy required man power, as and when required for attending breakdown within minimum time as detailed in Tech. Specification and distribution code) and maintain the required records as per U.P.P.C.L. (AOR) 178 SUBHEAD-I (Equipments H T Panels Transformers and Main L T Panel, capacitor Panel 11 KV RMU Panel (3 Way RMU) Design manufacture testing at works supply, installation testing & commissioning of 3 panel Board 11KV, Indoor tree standing, floor mounting totally enclosed mela clad VCB insulated comprising of 1 Nos 11KV isolater load break switch and 2 Nos Vaccum circuit breaker as outgoing enclosed in robotically laser weided non-extensible type stainless steel SF6 VCB enclosre with SelfPowered relay (IDMTL O/C +E/F) as HT switchgear including suitable transformer protection relays, metering, indicators push buttons, copper busbars, etc as per the requirement complete as required The fault with stand capacity shall beminimum 20KA for 1 second including four cable entries for two incoming cable and two outgoning cable glands and lugs suitable for 2x 240/185 sqmm XLPE armoure cable (Make- ABB, Crompton, Schnieder, Seimens) 179 Incomer shall be provided with Incomer shall be provided with integral Earthing Switch with making switch Live Cable Indicating LEDs energized thru Capacitive Voltage Deviders Transparent Viewing window for verification of Earthing Right Angle terminal protectors / Boots Electrical & mechanical indications as required Outgoing feeders: Two nos. Vaccum circuit breakers with the following SF-6 insulated 630A Circuit Breaker integral Earthing Switch with making switch Emergency Trip Push Button, Electrical & mechanical indications as required Shunt Trip coil for external trip signal Live Cable Indicating LEDs energized thru Capacitive Voltage Dididers Transparent Viewing window for verification of Earthing Right Angle terminal protectors /Boots IDMT relay for Circuit Breakers self powered, Merlin Gerin type VIP35 or equivalent with required protection CTs of suitable ratio Cable box for incoming and outgoing shall be suitable for icrminating, 11KV, XLPE insulated Aluminium conductor armoured cables One set inbuilt DC power packTransformer protection relays as required as per SLD
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
42.
Public Administrative Department #10714170 Price Bid
Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan EARTH WORKClearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201. 2 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil. Upto 3.0 m depth. 3 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m. 4 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 5 In ordinary rock. Depth upto 1.5 M. 6 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.2.1 7 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Upto 1 Km 8 Stone, boulders, gravelly materia 9 Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 10 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 11 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification including all material, labour, machinery as per clause 710.1.4 of IRC:78 and clause 2200 of MoRT&H specification. 12 CONCRETE WORK 13 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 15 REINFORCED CEMENT CONCRETE 16 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix). 17 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 19 Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto two stories excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 20 Providing and laying upto two stories reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 21 Add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof. 22 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 23 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 Suspended floors, roofs, landings, balconies and access platform. 25 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 26 Columns, Pillars, Piers, Abutments, Posts and Struts.22.1.5 27 Stairs, (excluding landings) except spiral-staircases. 28 Extra for shuttering in circular work (20% of respective centring and shuttering items). 29 Edges of slabs and breaks in floors and walls. Under 20 cm wide. 30 Weather shade, Chajjas, corbels etc., including edges. 31 Add extra for doing centering and shutteriing work for every additional height of 1 metre or part thereof beyond initial 7.5 metre height from plinth level. 32 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. 33 BRICK / STONE MASONERY WORK 34 Brick work with FPS bricks of class designation 75 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 35 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand). 36 Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:3 (1 cement :3 coarse sand). 37 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 38 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand). 39 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green / Black Above 3601 Cm2 Slabs. 40 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Moulding. 41 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 42 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 43 Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles 44 Providing and fixing Motive pieces all coloures for glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. Size 200 x 300mm. 45 P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm. 46 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) Size 300mm x 450mm. 47 Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete. (excluding the the cost of cement plaster on wall and pillar). Size 600mm x 1200mm 48 38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. 49 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 50 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone. 51 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 52 ROOFING 53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75mm deep chase. 54 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m². 55 Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre 0.80 mm thick 56 Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m² 57 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand) 58 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand). 59 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 60 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 61 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) toplayer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand). Design on outer plaster. 62 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 64 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 65 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work. 66 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 67 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8193, density 16kg/m3 , 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 68 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces/ceilings with full threaded, cadmium plated steel screws 4mm dia. stem, 30mm long and aluminium washers 2mm thick, 15mm dia. at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron). 69 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. 70 Providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of MoRT&H Specification including all material, labour, machinary etc. 71 Fillar joint with 20m thick compressible fibre board. 72 Fillar joint with Joint sealing compound with coarse sand and 6 %bitumen by weight. 73 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: Hot finished seamless type tubes. 74 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 76 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube. 77 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 78 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure A : 30 mm thick Decorative teak veneer both side. 79 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). Decorative teak veneer both side. 80 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) Rectangular or square. 81 Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area ofthe shutter to be measured). 82 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 50 mm long. 83 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm dia. 84 Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre-laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded Pre-laminated PVC C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side Pre-laminated PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification & drawing (for W.C. and bathroom door shutter). 85 ALUMINIUM WORK 86 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). 87 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron). 88 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 25 mm thick 89 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basicitem) : With float glass panes of 5.50 mm thickness. 90 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. 91 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete. 355 X 19 mm. 92 INTERIOR WORK 93 FALSE CEILING 94 Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I, 95 Sanitary Items 96 Plumbing 97 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour. 98 15 mm nominal bore with 3 cm length. 99 15 mm nominal bore with 45 cm length. 100 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 101 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 102 15 mm nominal bore 103 20 mm nominal bore 104 25 mm nominal bore 105 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 106 25 mm nominal bore Horizontal 107 25 mm nominal bore Vertical 108 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 109 Sanitary 110 Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : Upto 300 mm dia. 111 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 112 100 mm dia. pipe 113 125 mm diameter pipe 114 Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead : 115 100 mm diameter pipe 116 125 mm diameter pipe 117 Supplying pig lead at site of work. 118 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter 119 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 120 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With bricks with class designation 75 121 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With bricks class designation 75 122 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With bricks class designation 75. 123 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design With bricks. 124 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design With bricks 125 Fixtures 126 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. 127 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers. 128 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 130 Rectangular shape 453x357mm 131 Rectangular shape 1500x450 mm 132 Providing and fixing 100 mm sand cast Iron grating for gully trap 133 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 134 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet 135 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 136 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 137 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth. Granite Stone of approved shade 138 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 139 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 140 Internal work - Exposed on wall 15 mm dia. nominal bore 141 Internal work - Exposed on wall 20 mm dia. nominal bore 142 Internal work - Exposed on wall 25 mm dia. nominal bore 143 Internal work - Exposed on wall 32 mm dia. nominal bore 144 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore 145 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia. nominal bore 146 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 147 15 mm dia. nominal bore 148 20 mm dia. nominal bore 149 25 mm dia. nominal bore 150 32 mm dia. nominal bore 151 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work : 152 15 mm dia. nominal bore 153 20 mm dia. nominal bore 154 25 mm dia. nominal bore 155 32 mm dia. nominal bore 156 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 157 15 mm dia. nominal bore 158 20 mm dia. nominal bore 159 25 mm dia. nominal bore 160 32 mm dia. nominal bore 161 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 162 15 mm nominal bore 163 20 mm nominal bore 164 25 mm nominal bore 165 WATER HARVESTING SYSTEM 166 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm dia Nominal bore 167 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 of following nominal bore sizes at site of work. 200 mm dia 168 Supply and fixing of M.S. clamp set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 169 Providing & lowering of G.I. flange pipe B Class including rubber washer and nuts of 8 mm dia complete in all respect. 50 mm dia 170 Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. 171 ELECTRICAL G-SCHEDULE 172 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 173 Short point (up to 3 mtr.) 174 Medium point (up to 6 mtr.) 175 Long point(up to 10 mtr..) 176 Wiring of twin control light / fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its accessories, round tles,18 SWG M.S. box with earth terminal, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 177 Short point (up to 3 mtr.) 178 Medium point (up to 6 mtr.) 179 Long point(up to 10 mtr..) 180 Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed 1.1 kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated unsheathed 1.1 kV grade copper earth conductor (IS:694) of approved make double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 181 On board 182 Short point (up to 3 mtr.) 183 Medium point (up to 6 mtr.) 184 Long point(up to 10 mtr..) 185 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 186 20 mm 187 25 mm 188 32 mm 189 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 190 3x 1.5 sq.mm 191 2 x 2.5 sq. mm. + 1x1.5sqmm 192 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 193 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 194 4 x 10.0 sq.mm 195 4 x 16.0 sq.mm 196 Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. 197 RG - 6 198 RG -11 199 Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS-112C &113 C of approved make in existing surface or recessed conduit/casing capping. 200 Unarmoured 2 pair 201 Unarmoured 10 pair 202 Unarmoured 20 pair 203 Unarmoured 50 pair 204 Jelly filled armoured (PIJF) 5 pair 205 Jelly filled armoured (PIJF) 10 pair 206 Jelly filled armoured (PIJF) 20 pair 207 Jelly filled armoured (PIJF) 50 pair 208 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Double door (Three phase) Per phase isolation 209 2+8 Way 210 2+12 Way 211 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 212 2.5 Sq. mm 4 core 213 4.0 Sq.mm 4 core 214 6.0 Sq.mm 4 core 215 10.0 Sq.mm 4 core 216 16.0 Sq.mm 4 core 217 25.0 Sq.mm 3.5 core 218 35.0 Sq.mm 3.5 core 219 50.0 Sq.mm 3.5 core 220 70.0 Sq,mm 3.5 core 221 95.0 Sq.mm 3.5 core 222 120.0 Sq.mm 3.5 core 223 150.0 Sq.mm 3.5 core 224 240.0 Sq.mm 3.5 core 225 300.0 Sq.mm 3.5 core 226 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 227 3.5 x 25.0 sq.mm 228 3.5 x 35.0 sq.mm 229 3.5 x 50.0 sq.mm 230 3.5 x 70.0 sq.mm 231 3.5 x 95.0 sq.mm 232 3.5 x 120.0 sq.mm 233 3.5 x 150.0 sq.mm 234 3.5 x 240.0 sq.mm 235 3.5 x 300.0 sq.mm 236 4 x 2.5 sq.mm 237 4 x 4.0 sq.mm 238 4 x 6.0 sq.mm 239 4 x 10.0 sq.mm 240 4 x 16.0 sq.mm 241 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. Hot Dipped Galvanized. 242 150mm x 50mm x 1.6mm 243 300mm x 50mm x 1.6mm 244 450mm x 50mm x 2.0mm 245 600mm x 50mm x 2.0mm 246 Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I. coating With pipe in pipe technology with 80-100 micron G.I. coating G.I. pipe 3000 mm long , 80/40 mm , terminal 14 mm G.I. strip 247 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 248 8 SWG copper Wire 249 25mm x 3mm copper strip 250 50mm x 6mm copper strip 251 25mm x 3mm G.I. ( Hot Dipped) Strip 252 25mm x 6mm G.I. ( Hot Dipped) Strip 253 P & F of IP20 LED Recessed/ Surface Mounted Round/ sqaure Non Dimmable Downlight with die-cast aluminum housing & Heat sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. ( supplied together with luminaire) Power consumption of =< 7w/10w/8w/12w/15w/18W with 100/500/750/1100/1250 lumens, system lumen, efficeancy of 70 lm / Watt or 100 lm / Watt output suitable to replace 1x18W/ 2x18w/2x26w CFL downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE Compliance. 254 Recessed mounting LED Downlight 18/20W 255 Surface Mounting LED Downlight 18/20W 256 P & F of IP20 LED Ceiling/ Recessed/ suspended mounting light fixture made form CRCA sheet steel housing, high purity/ transmisivity diffuser for uniform light distrubution.High efficiency driver electronics having efficiency > 85% and in compliance to IEC standards.(integral driver). Power consumption of 40 W/50W/60W, 3000/3300/4200 lumens, system lumen efficiency of 70-80 lm / Watt output suitable for 2x36W FTL/ 2x36w CFL/3x36w CFL light fixtures, life time of 50000 burning Hours with 70% intial Lumens maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE compliance. Surface Mounting 36W LED Light 2’x2’ with acrylic/ prismatic front cover 257 P & F energy efficient direct fit (Retrofit) LED tube system (with integral driver), on existing fixture. Power Consumption of18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K& 6000°K. 4 LED Tube shape fixture 18W. 258 P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries LED street light fixture 150 watt 259 Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 9 Mtr. 260 Supply, Installation, Testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformers described as above and as per the following continuous rating. 315KVA 261 Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 11 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25KA/3 and IAC A-FLR for 25kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make. 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. 262 SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel tank ( with Stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183 .The doors are fabricated from 1.6 mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 °C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system mccb Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 db (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity : Radiator cooled and turbo charged 250 KVA at 0.8 pf 415V 50Hz 3-?. 263 Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides. 264 Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 265 FIRE ALARM G-SCHEDULE 266 SITC of microprocessor based 2 - wire loop (each loop accessing 90 addressable units ) Fire Alarm Control Panel. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. The Panel shall also be able to give voice announcement to individualized speakers. The Panel shall have built in sounder, Maintenance Free Batteries of minimum 15 Ah of 24 volts capable of minimum of 12 hours with battery charger, rectifier. Loop cards, LCD unit to indicate Fire / Fault Signal of individual unit, built in-built / external printer, to log all incoming data etc complete in all respect. 2-LOOP. 267 SITC Manual Call Point complete with , Glass, hammer and chain etc as required: Analogue addressable type 268 SITC Automatic commendable Control Switches for shutting downAC Plant, Power Supply, Gas Supply etc. Response Indicators. 269 SITC Fault Isolators for isolating shorted, dead wire and loose circuits between two successive Fault Isolators with automatic resetting arrangement. Analogue addressable type. 270 FIRE FIGHTING G-SCHEDULE 271 Sub Head - I - (Wet Riser System - Pumping Equipments)SITC of electric driven Sprinkler / Hydrant pump Suitable for automatic Operation consisting of the following-(A) Horizontal multi stage Centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump.(B) Squirrel cage induction motor suitable for 415 V, 50 HZ, Ac supply of below mentioned HP for the above pump ,1450 RPM T.E.F.C confirming to IP:55 and flexible coupling and coupling guard with the pump. (C) Common bed plate fabricated from mild steel channel or cast iron type1620 LPM at 70 Mtr Head ( 50 HP Motor) 272 SITC of diesel engine drive Standby Pump suitable for automatic operation consisting of the following A, B, C. .The Diesel driven pump shall be suitable for following discharge:(A) Horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump.(B) Water cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, d cushy foot, damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of 12/24v, 88 Ah, 13/21 plate, Exhaust Pipe of minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumpingset, Supply, installation, testing, & commissioning of electric driven automatic pressurization pump setC) Horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required.1620 LPM at 70 Mtr Head ( 50 HP Engine) 273 SITC of Jockey pump having Squirrel cage induction motor suitable for 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 and flexible coupling and coupling guard with the pump ,Common bed plate of fabricated mild steel channel or cast iron type. 180 LPM at 70 Mtr (15 HP). 274 Supplying & Installing cylindrical type air vessel, 250 mm dia 1.5M high of thickness 6.0 mm M.S. complete with air release valve, safety valve, pressure gauge etc.along with two coats of Red Oxide and two coat of post office red enamel paint as required. 275 Providing & fixing 100mm dia pressure Gauge on Pump DeliveryLine complete with shut off cock. 276 SITC of pressure switches for Main, Jockey, and standby pumps,including necessary wiring UPTO control panel and stop valve. 277 Sub Head - II - (Hydrants System) 278 Providing and fixing single headed hydrant valves with flanged inletISI marked with 63 mm female instantaneous outlet of gun metalcomplete with blank cap and chain conforming to IS : 5290 279 Providing . 63 mm dia 15 M long reinforced rubber hose pipeconforming to IS : 636-1962, Part –A & ISI marked with Gun Metalmale & female coupling wire wound with the pipe. 280 Providing & fixing (1.0 M x .45 M x 0.6 M ) OUTDOOR HOSECABINET suitable for accommodating hydrants made of not lessthan 16 swg. M. S. sheet having central opening glazed doorincluding necessary locking arrangement, painting (one coat primer& two coats of paint ) and housing 2 Nos. RRL hose pipe, 1 Nobranch pipe. 281 Providing and fixing Swinging Drum type hose reel ISI marked 30M(L) x 20 mm (dia) rubber lined pipe with shut off nozzle of 6 mm diaincluding the cost of 25 mm dia pipe connection from riser to hosereel , all sockets, nipples, elbows and 25 mm globe valve. 282 Providing and fixing ISI marked Three Way fire Brigade Inlet to wetRiser with non return valve complete in all respects 283 Providing, fixing, jointing and testing of Heavy Gauge (C class ) MSPipe ISI marked with accessories like tees, elbows, flanged joints,reducers, compressed asbestos gaskets, nuts and bolts includingfixing the pipe with suitable flat iron strip clamps /bracket, paintingetc. Complete as required for delivery/ suction manifold relating tothe pump including painting of two coats of Red Oxide and two coatof post office red enamel paint including all civil breakages andmaking good the same : 284 200mm dia 285 150 mm dia 286 80 mm dia 287 Sub Head - III - (Piping, Valves and Accessories) 288 MS (Medium duty B class) pipe with cleaning,wrapping and coatingof the pipe as per IS; 10221 in all kind of soil at 1.0 M depthincluding excavation as required. 289 150 mm dia 290 100 mm dia 291 80 mm dia 292 Providing & fixing Butterfly valve with Cast Iron Body, Cast Iron Discand Seat of Nitrile Rubber Bonded on Bakelite with hard back to PN1.6 rating with following sizes complete with bolts, washers andcompressed asbestos gasket as required 293 150 mm dia 294 100 mm dia 295 80 mm dia 296 Providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 297 200 mm dia 298 150 mm dia 299 80 mm dia 300 Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5kg capacity. 301 Providing, fixing, testing & commissioning of sprinkler heads of thefollowing type : Pendant type with quartziod bulb, operating temperature at 68 deg Cas per specifications. 302 Providing & fixing 10 SWG chrome plated brass 100 mm diadecorative flanges / escutcheon plates to be fixed at junction ofSprinkler piping with the false ceiling. 303 Sub Head - III - (Piping, Valves and Accessories) 304 Sub Head - IV (Fire Electrical Control Panel) 305 Supplying and making end termination with heavy copper lugs (pin/ring type) duty crimped with crimping tool, PVC tape etc of followingsize 306 1.5 Sq.mm 307 10.0 Sq.mm 308 35.0 Sq.mm 309 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. 100mm x 50mm x 1.6mm 310 BOUNDARY WALL G-SCHEDULE 311 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 312 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 313 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 314 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) 315 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 316 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 317 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 318 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 319 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing. 320 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand) 321 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 322 EARTH WORK 323 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 324 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil Upto 3.0 m depth. 325 EXTERNAL DEVELOPMENT 326 Compacting original ground 327 Loosening upto a level of 500 mm below the subgrade level watered, graded and compacted in layers by vibratory roller 8-10 tonne to meet requirement of table 300-2 for subgrade construction as per MoRT&H specification clause 305.3.4. 328 Loosening and recompacting original ground below embankment including Loosening leveling and recompacting original ground supporting embankment to facilitate placement of of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling by vibratory roller 8-10 tonne so as to achieve minimum dry density as given in table 300-2 for embankment construction as per MoRT&H specification clause 305.3.4. 329 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 330 CEMENT CONCRETE PAVEMENTS 331 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 332 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-30. 333 Providing and laying cast-in-situ cement concrete M-20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick PCC M10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. Using Concrete Mixer. 334 Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. 335 Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. 336 Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer. Note : E/w to be measured and paid separately. 300 mm internal diameter. 337 Horticulture Work 338 Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction. 339 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 340 Ficus panda 341 Tecoma capensis ( Ratanjot) 342 Clerodendron inermii ( Choti Aari) 343 Tabernaemontana variegated ( Chandni) 344 Hamelia patens ( Firebush, Thal Kamal) 345 Hibiscus variegated ( Guddal) 346 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 347 Wedelia trilobata ( SunFlower Family) 348 Alternathera green (Parrot Leaf) 349 Iresine herbstii (Blood Leaf) 350 Ophiopogon Black ( Lily Turf, Mondograss) 351 Asparagus myerii (Fox Tail) 352 Lantana sellowiana 353 Rhoeo spathacea Compacta‘ ( Oyster, Boat Lily) 354 Golden duranta 355 Pennisetum setaceum (Fountain Grass)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
43.
Shipping #10696492 Price Bid
Triennial Repairs And Maintenance Contract Of Electrical Installations After Metering Point Under The Jurisdiction Of Meed.; 2 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Ofofficer’S Residential Buildings Including Operation Of Water Pumps As Per List I ( A ) . 3 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Ofofficer’S Bungalow Including Operation Of Water Pumps As Per List I ( B ) . 4 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Class Iii Residential Buildings Including Operation Of Water Pumps As Per List Ii. 5 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( More Than G+2 Floors ) Including Operation Of Water Pumps As Per List Iii ( A ) . 6 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( Having Upto G+2 Floors ) Including Operation Of Water Pumps As Per List Iii ( B ) . 7 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( Having Ground Floors Only ) Including Operation Of Water Pumps As Per List Iii ( C ) . 8 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Open Yards / Plots Including Operation Of Water Pumps As Per List Iv. 9 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Sheds Including Operation Of Water Pumps As Per List V. 10 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Class Iv Residential Buildings Including Operation Of Water Pumps As Per List Vi. 11 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Hospital Including Operation Of Water Pumps As Per List Vii. 12 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Streets / Roads / Area Lighting As Per List Viii. 13 Second Year Charges 14 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Ofofficer’S Residential Buildings Including Operation Of Water Pumps As Per List I ( A ) . 15 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Ofofficer’S Bungalow Including Operation Of Water Pumps As Per List I ( B ) . 16 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Class Iii Residential Buildings Including Operation Of Water Pumps As Per List Ii. 17 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( More Than G+2 Floors ) Including Operation Of Water Pumps As Per List Iii ( A ) . 18 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( Having Upto G+2 Floors ) Including Operation Of Water Pumps As Per List Iii ( B ) . 19 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( Having Ground Floors Only ) Including Operation Of Water Pumps As Per List Iii ( C ) . 20 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Open Yards / Plots Including Operation Of Water Pumps As Per List Iv. 21 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Sheds Including Operation Of Water Pumps As Per List V. 22 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Class Iv Residential Buildings Including Operation Of Water Pumps As Per List Vi. 23 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Hospital Including Operation Of Water Pumps As Per List Vii. 24 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Streets / Roads / Area Lighting As Per List Viii. 25 Third Year Charges 26 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Ofofficer’S Residential Buildings Including Operation Of Water Pumps As Per List I ( A ) . 27 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Ofofficer’S Bungalow Including Operation Of Water Pumps As Per List I ( B ) . 28 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Class Iii Residential Buildings Including Operation Of Water Pumps As Per List Ii. 29 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( More Than G+2 Floors ) Including Operation Of Water Pumps As Per List Iii ( A ) . 30 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( Having Upto G+2 Floors ) Including Operation Of Water Pumps As Per List Iii ( B ) . 31 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Office Building ( Having Ground Floors Only ) Including Operation Of Water Pumps As Per List Iii ( C ) . 32 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Open Yards / Plots Including Operation Of Water Pumps As Per List Iv. 33 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Sheds Including Operation Of Water Pumps As Per List V. 34 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Class Iv Residential Buildings Including Operation Of Water Pumps As Per List Vi. 35 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Hospital Including Operation Of Water Pumps As Per List Vii. 36 Attending Faults And Carrying Out Repairs Activity To The Electric Installations Of Streets / Roads / Area Lighting As Per List Viii. 37 Part Brate Contract For Electrical Point Wiring Works 38 Wiring In Pvc Casing & Capping System Using Rigid Pvc Casing & Capping, 3 X 4 Sq. Mm ( Phase, Neutral & Earth Wire ) 660 / 1100V Grade Fr-Pvc Insulated Copper Conductor Single Core Wires For One No. Wall Socket Outlet Point, 3 Pins, 20A, 230V Modular Type Switch & Socket On Separate Board Using Heavy Duty Surface Plastic Box With Plate & Base Frame, Etc. Circuit To Be Tapped From The Nearest Mcbdb / Sfu / Mcb Units, Etc. 39 Wiring In Pvc Casing & Capping System Using Heavy Duty Rigid Pvc Casing & Capping, 3 X 1.5 Sq Mm ( Phase, Neutral, Earth ) 660 / 1100V Grade Fr-Pvc Insulated Copper Conductor Single Core Wires For Two Nos. Wall Socket Outlet Points, 3 Pins, 6A, 230V Modular Type Switches & Sockets On Separate Board Using Heavy Duty Surface Plastic Box With Plate & Base Frame, Etc. Circuit To Be Tapped From The Nearest Mcbdb / Sfu / Mcb Units, Etc. 40 Wiring In Pvc Casing & Capping System Using Rigid Pvc Casing & Capping, 2 X 1.5 Sq.Mm 660 / 1100V Grade Fr-Pvc Insulated Copper Conductor Single Core Wires With Modular Type Switches, Sockets, Surface Mounting Plastic / G.I. Metal Boxes, Plates With Base Frames, Etc. For Light Point / Ceiling Fan Point / Exhaust Fan Point / Call Bell / Buzzer Point / Socket Point, Etc.To Be Terminated In 2 / 3 Plates Ceiling Rose / Batten / Angle Holder Including Main Circuit Wiring. For Circuits And Socket Points Wiring, 3 X 2.5 Sq. Mm. ( Phase, Neutral, Earth ) 660 / 1100V Grade Fr-Pvc Insulated Copper Conductor Single Core Wires Shall Be Used. Circuit To Be Tapped From The Nearest Mcbdb / Sfu / Mcb Units, Etc. 41 Wiring In Pvc Casing & Capping System Using Rigid Pvc Casing & Capping, 2 X 1.5 Sq.Mm 660 / 1100V Grade Fr-Pvc Insulated Copper Conductor Single Core Wires With Modular Type Switches, Sockets, Surface Mounting Plastic / G.I. Metal Boxes, Plates With Base Frames, Etc. For Light Point / Ceiling Fan Point / Exhaust Fan Point / Call Bell / Buzzer Point / Socket Point, Etc.To Be Terminated In 2 / 3 Plates Ceiling Rose / Batten / Angle Holder Including Main Circuit Wiring. For Circuits And Socket Points Wiring, 3 X 2.5 Sq. Mm. ( Phase, Neutral, Earth ) 660 / 1100V Grade Fr-Pvc Insulated Copper Conductor Single Core Wires Shall Be Used. Circuit To Be Tapped From The Nearest Mcbdb / Sfu / Mcb Units, Etc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Maharashtra View Result →
44.
Health and Family Welfare #10690140 Price Bid
Procurement Of Generic Medicine Surgical Items And X Ray Films , Brief Discription Of Medicine, Surgical Items And X-Ray Films , Aceclofenac Tablet 100 Mg , Acetazolamide Tablet 250 Mg , Acetazolamide Tablet 500 Mg , Acetic Acid 500 Ml Nice , Acetone 2.5 Litre Nice , Acetone 400 Ml Nice , Acetylsalicylic Acid Tablet 150 Mg , Acetylsalicylic Acid Tablet 75 Mg , Acyclovir Eye Ointment 3% , 4.5 Gm Tube , Acyclovir Tablet 400 Mg , Acyclovir Tablet 800 Mg , Acylovir Eye Oint 5%, 5 Gm , Adenosin Injection 3 Mg / 1Ml , Adenosin Injection 6 Mg / 2Ml , Adrenaline Injection 1 Mg / Ml, 1 Ml Ampoule , Albendazole Chewable Tablet 400 Mg , Albendazole Oral Suspension 200 Mg / 5 Ml, 10 Ml Bottle , Albumin Infusion ( 20% ) 100Ml , Alfacalcidol Soft Gelatin Capsule 0.25 Mcg , Allopurinol Tablet 100 Mg , Alprazolam Tablet 0.25 Mg , Alprazolam Tablet 0.5 Mg , Altplase 20Mg Injection , Altplase 50 Mg Injection , Aluminium Hydroxide + Magnesium Hydroxide + Simethicone Oral Solution 300 Mg+ 150 Mg+ 40 Mg / 5 Ml200ml Suspension , Aluminium Hydroxide + Magnesium Hydroxide + Simethicone+ Magnesium Carbonate240 Mg+100 Mg+ 25 Mg + 60 Mg Chewable Tablet , Amenophylline Injection 25 Mg / Ml, 10 Ml Ampoule , Amikacin Injection 100 Mg / 2 Ml , Amikacin Injection 250 Mg / 2 Ml , Amikacin Injection 50 Mg / Ml, 2 Ml Vial , Amikacin Injection 500 Mg / 2 Ml , Amino Acid Iv Infusion Minimum 10 Essential Amino Acids, 200Ml Bottle , Aminoacid +Sorbital 5%200Ml Injection , Amiodarone Hcl Injection 150Mg / 3Ml , Amiodarone Tablet 100 Mg , Amitriptyline Tablet 10 Mg , Amlodipine Tablet 10 Mg , Amlodipine Tablet 5 Mg , Amoxicillin + Clavulanic Acid Injection 250 Mg +50 Mg, Vial With Diluents , Amoxicillin + Clavulanic Acid Suspension 200 Mg + 28.5 Mg In 5Ml , Amoxicillin + Pottasium Clavulanate Injection 1 Gm + 200 Mg , Amoxicillin + Pottasium Clavulanate Tablet 500 Mg + 125 Mg , Amoxicillin Capsule 250 Mg , Amoxicillin Capsule 500 Mg , Amoxicillin Oral Suspension 125 Mg / 5 Ml, 60 Ml Bottle , Amoxy + Potassium Clavulnateinjection 500Mg+100Mg , Ampicillin Injection 500 Mg , Anti Rabies Immunoglobulin Injection ( Human ) 150 Iu / Ml, 2Ml Vial , Anti Rabies Immunoglobulin Injection 300Iu / Ml , Anti Rabies Vaccine ( Chick-Embryo / Verocell / Human Diploid ) ( Id ) Injection 1Ml. , Anti Rabies Vaccine ( Chick-Embryo / Verocell / Human Diploid ) ( Im ) Injection 0.5Ml. , Anti-Haemorrhoidal Containing: Beclomethasone Dipropionate 0.025% W / W, Phenylephrine Hyderochloride 0.10% W / W, Lignocaine Hydrochloride 2.5% W / W In Soft Paraffin Base 20 Gm Tube , Anti-Rho-D Immunoglobulin ( Human ) Injection ( Polyclonal ) Injection 150 Mcg / Vial , Anti-Rho-D Immunoglobulin ( Human ) Injection ( Polyclonal ) Injection 300Mcg / Vial , Antisnake Venom ( Polyvalent Solution ) Injection 10 Ml , Antisnake Venom ( Polyvalent Solution ) ( Dry Powder ) Injection 10 Ml Vial , Aripipralzole Tablet 10 Mg , Ascorbic Acid Injection 250 Mg / Ml 2Ml Ampoule , Ascorbic Acid Tablet 500 Mg , Atenolol Tablet 50 Mg , Atorvastatin Tablet 10 Mg , Atorvastatin Tablet 20 Mg , Atracurium Besylate Injection 10 Mg / Ml, 2.5 Ml Amp. , Atropine Drops 1%3Ml , Atropine Eye Ointment 1%3Gm , Atropine Injection 0.6 Mg / Ml, 1 Ml Ampoule , Azathoprine Tablet 50 Mg Tablet , Azithromycin Oral Solution 200 Mg / 5 Ml , Azithromycin Tablet 250 Mg , Azithromycin Tablet 500 Mg , B-Complex Tablet , B-Complex With B 12 Tablet-Thiamine 10 Mg + Riboflavin 10 Mg+ Pyrodoxin 2 Mg+Cynocobalamin 15 Mcg+Nicotinamide 45 Mg+ Calcium Panthonate 50 Mg , Beclomethasone Inhalation ( Mdi ) 200 Microgram / Dose , Benzoyl Per Oxide Gel 2.5%, 20 Gm Tube , Betamethasone Dipropionate Cream 0.1 %20Gm , Betamethasone Dipropionate Cream 0.1% W / W , 5 Gm , Betamethasone Tablet , Betahitidin Tablet 8 Mg , Betahitidin Tablet 16 Mg , Betahitidin Tablet 24 Mg , Biotin Tablet 10 Mg , Biphasic Isophane Insulin 40 I.U / Ml Injection , Bisacodyl Gastro-Resistant ( Enteric Coated / Delayed Release ) Tablet 5 Mg , Bisoprolol Tablet 2.5Mg , Bleaching Powder ( Contains Not Less Than 30%W / W Of Available Chlorine ) 1 Kg , Bleaching Powder ( Contains Not Less Than 30%W / W Of Available Chlorine ) 25 Kg , Boroglycerine Mouth Paint , Botropase1cu / Ml 02 Mlinjection , Bromocriptine ( Mesylate ) Tablet 2.5 Mg , Budesonide + Formoterol Inhalation ( 200 Mcg + 6 Mcg ) , 120 Mdi , Budesonide Inhalation 200 Mcg / Dose, 200 Mdi / Dpi , Budesonide Nasal Spray 100 Mcg / Dose , Budesonide Nebulizer Solution 15 Ml Vial , Budesonide Respirator Solution For Use In Nebulizer 1 Mg, 2Ml Respule , Bupivacaine Injection 0.5%, 5Ml Amp. , Bupivacaine Injection 0.5%, 30 Ml Vial. , Bupivaccine Heavy 5 Mg With Dextrose Monohydrate 80 Mg / Ml Injection 4 Ml Ampoule , Bupivacine 0.5 % 20 Ml Injection , Buprenorphine Tablet ( Sublingual ) 0.4Mg , Buprinorphine Tablet 2 Mg , Bupropion Tablet 150 Mg , Bupropion Tablet 300 Mg , Cabgolin 0.5 Mg Tablet , Caffeine Citrate 1 Ml. Syrup , Caffeine Citrate 2 Ml. Injection , Caffeine Citrate 2 Ml. Syrup , Calamine Lotion 8 % 100 Ml , Calcium Gluconate Injection 100 Mg / Ml, 10 Ml Amp , Calcium Phosphate Syrup , Calcium Polystyrene Sulphonat 15Mg , Calcium Salts + D3 Tablet ( 500 Mg + 250 Iu ) , Camphor Phenol , Carbamazepine Oral Solution 100Mg / 5Ml, 30 Ml Bottle , Carbamazepine Tablet 200 Mg , Carbamazepine Tablet 400 Mg , Carbimazole Tablet 5 Mg , Carboprost Injection 25 Mg / Ml , 250 Mcg , Carvediolol Tablet 3.125 Mg , Cefadroxil Oral Solution 125 Mg / 5 Ml, 30 Ml Bottle , Cefixime Syrup 50 Mg / 5 Ml, 30 Ml , Cefixime Tablet 100 Mg , Cefixime Tablet 200 Mg , Cefoperazone + Sulbactam ( 1G+1G ) Injection , Cefoperazone 1Gm Injection , Cefoperazone 1Gm+ Salbectam 500 Mg Injection , Cefotaxim 1000 Mg + Salbactam 500Mg Injection , Cefotaxime Injection 1 Gm , Cefotaxime Injection 250 Mg , Cefotaxime Injection 500 Mg 5 Ml Vial With Diluent , Cefotaxime Sodium Injection 1 Gm 10 Ml Vial With Diluent , Cefpodoxime Cv 200+125 Mg Tablet , Ceftriaxine 1Gm+ Salbactam 500Mg Injection , Ceftriaxone Injection 1 G, 10 Ml Vial , Ceftriaxone Injection 250 Mg 2 Ml Vial With Diluent , Ceftriaxone Injection 500 Mg , Cefuroxime Cv 250+62.5Mg Tablet , Cerebrolysin Solution For Injection 10Ml. , Cetrimide Solution 20% Conc. For Dilution , Cetrimide Solution + Chlorohexidine Solution 1 Litre Pack , Cetrizine Oral Solution 5 Mg / 5 Ml 60 Ml , Cetrizine Tablet 10 Mg , Chloramphenicol Eye Ointment 1%5Gm , Chloremphenicol +Beclomethasone Dipropoinate +Clotrimazole + Lignocaine Hcl Ear Drops 5 % + 0.025%+ 1 %+2 % W / V 10 Ml , Chlorhexidine Solution 5% Conc. For Dilution, 500 Ml , Chlorine / Drink Well Tablet With Test Report ( Isi Marked ) 1000 Tab. , Chlorpheniramine Tablet 4 Mg , Chlorpromazine ( Hydrochloride ) Tablet 100 Mg , Chlorpromazine Tablet 50 Mg , Cinnarizine Tablet 25 Mg , Ciprofloxacin + Dexamethasone Eye / Ear Drops 0.3% + 0.1% 5Ml , Ciprofloxacin Eye / Ear Drops 0.3 % 5Ml , Ciprofloxacin Eye Drops 0.3%, 10 Ml Plastic Bottle , Ciprofloxacin Injection Iv 2Mg / Ml, 100 Ml , Ciprofloxacin Ointment 0.3 % 5Gm , Ciprofloxacin Tablet 250 Mg , Ciprofloxacin Tablet 500 Mg , Clindamycin Gel 1% W / W10 Gm , Clindamycine 600Mg Injection , Clinidipine Tablet 20 Mg , Clobazam Capsule 10 Mg , Clobetasol + Gentamycin Ointment 0.05% + 0.1 %15Gm , Clomifene Citrate Tablet 50 Mg , Clonazepam 0.5 Mg Tablet , Clonazepam 1 Mg Tablet , Clonidine1ml Amp Injection , Clopidogrel Tablet 75 Mg , Clotrimazole + Ofloxacin + Dexamethasone Ear Drops 1% W / V 10Ml , Clotrimazole 1% W / V + Lignocaine Hydrochloride 2% W / V Ear Drops 5 Ml Vial , Clotrimazole Cream 2 %15Gm , Clotrimazole Ear Drops 1% W / V 10Ml , Clotrimazole Ear Drops 5 Ml Vial , Clotrimazole Mouth Paint 1% W / V In Propylene Glycone Glycerian Base 15 Ml , Clotrimazole Pessaries 200 Mg , Cloxacillin Capsule 500 Mg , Clozapinetablet 100Mg , Coal Tar Solution 5% W / V, 100 Ml Bottle , Cotrimazole 1 % + Betamethasone 0.0025% Lotion 15 Ml , Cotrimoxazole ( Sulfamethoxazole + Trimethoprim ) Tablet 800 Mg + 160 Mg , Co-Trimoxazole [ Sulphamethoxazole ( A ) + Trimetho Prim ( B ) ] Oral Liquid 200 Mg ( A ) + 40 Mg ( B ) / 5 Ml , Cotton Bandages ( 1 X 12 Rolls ) 10 Cm X 4 Mtrs As Per Isi Specification , Cotton Bandages ( 1 X 12 Rolls ) 15 Cm X 5 Mtrs As Per Isi Specification , Cotton Bandages ( 1 X 12 Rolls ) 5 Cm X 4 Mtrs As Per Isi Specification , Cotton Gauze Cloth 90 Cm X 18 Mtrs, 1 Piece As Per Isi Specification , Cotton Wool Ip 100 Gm Net ( Category :Surgical Dressing Absorbant Cotton Gossypium Linn, White Carbed Fiber, Staple Length Not Less Than 10Mm, Treated With Iodinized Zinc Chloride Solution ) , Cotton Wool Ip 500 Gm Net ( Category :Surgical Dressing Absorbant Cotton Gossypium Linn, White Carbed Fiber, Staple Length Not Less Than 10Mm, Treated With Iodinized Zinc Chloride Solution ) , Cough Expectorent ( Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg , Cough Syrup Ambroxol 15 Mg+ Terbutaline Sulphate 1.25 Mg+ Guaiphenesin 50 Mg+ Menthol 2.5 Mg, 100 Ml Bottle , Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg / 5 Ml, 100 Ml Bottle 110 Ml Bottle , Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg / 5 Ml, 100 Ml Bottle 110 Ml Bottle , Crape Bandages Bp 10 Cm X 4 Mtrs , Crape Bandages Bp 15 Cm X 4 Mtrs , Cyclopentolate Eye Drops 1% W / W 5Ml , Dantrolene Sodium Injection , Dapagliflozin Tablet 10Mg , Deferasirox ( Desirox ) Tablet 500 Mg , Deferiprone Tablet / Capsule 500 Mg , Derriphylin 02 Mlinjection , Dexamethasone Injection 4Mg / Ml 10 Ml , Dexamethasone Injection 4Mg / Ml 2 Ml , Dexamethasone Injection 4Mg / Ml 20 Ml , Dexamethasone Injection 4Mg / Ml 30 Ml , Dexamethasone Tablet 0.5 Mg , Dexmedetomidine100 Mcg / Ml 1Ml Injection , Dexomilk Powder ( 0 To 1 Year ) , Dexomilk Powder ( 7 Months Pri Maturebaby ) , Dextrose 5 % W / V With Sodium Chloride 0.9% W / V For Intravenous Infusion 500 Ml Ffs Bottle , Dextrose Intravenous Infusion Ip 25% W / V, 100 Ml Ffs Bottle , Dextrose Intravenous Infusion Ip 5 % W / V , 500 Ml Ffs Bottle , Dextrose Intravenus Infusion Ip 10% W / V, 500 Ml Ffs Bottle , Diacerein 50 Mg + Glucosamine Sulphate 500 Mg Tablet , Diazepam5mg / Ml 02 Ml Injection , Diazepam 5Mg / Ml2ml Injection , Diclofenac ( Sodium ) Injection 25 Mg / Ml , 3Ml Amp. , Diclofenac + Paracetamol Tablet 50Mg+325Mg , Diclofenac 1Ml I.V1ml ( Aquaous Prep. ) Injection , Diclofenac Gel 1% 30 Gm Tube , Diclofenac Injection 25 Mg / Ml , 3Ml Amp. , Diclofenac Sodium Gastro-Resistant Tablet 50 Mg , Dicyclomine Oral Solution 10Mg / 5Ml , Dicyclomine Tablet 10 Mg , Dicyclomine Tablet 10 Mg+Mefenamic Acid 250 Mg , Dicyclomine Tablet 20 Mg+Mefenamic Acid 250 Mg , Dicyclomine Tablet 20 Mg+Paracetamol Tablet 325 Mg , Digoxin Tablet 0.25 Mg , Diltiazem Injection 5 Mg / Ml , Diltiazem Tablet 30 Mg , Diltizem Hydrochloride Tablet 30 Mg ( Modified Release ) , 10*10 , Dinoprostone Gel 0.5Gm, 3Gm , Disodium Cromoglycate Ear Drops 5Ml , Disodium Hydrogen Citrate Suspension 1.38 Gm / 100 Ml , Distilled Water 5 Litrees Cane , Disulfiram Tablet 250 Mg , Divalproex Sodium Equivalent To Valproic Acid Tablet 250 Mg , Divalproex Sodium Equivalent To Valproic Acid Tablet 500 Mg , Dobutamine Injection 125 Mg / 5 Ml , Dobutamine Injection 250Mg / 5Ml , Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging , Domperidone Suspension 1 Mg / Ml, 30 Ml Bottle , Domperidone Tablet 10 Mg , Donepezil Tablet 10 Mg , Donepezil Tablet 5 Mg , Dopamine Injection 40 Mg / Ml In 5Ml Ampoule , Dothiepin Tablet 25 Mg , Doxofylline Tablet 400 Mg , Doxycycline Capsules 100 Mg , Doxylamine Tablet 10 Mg , Dried Aluminium Hydroxide Gel + Magnesium Hydroxide + Simethicone Oral Suspension 250 Mg+ 250 Mg+ 50 Mg / 5 Ml, 180 Ml Bottle , Drotavarin Syrup 10Mg / 5Ml, 100Ml , Drotaverine Injection 40 Mg / 2 Ml , Drotaverine Tablet 80 Mg , Duloxetine Tablet 30 Mg , Dutasteride Tablet 0.5 Mg , Dytor 10 Mg ( Torasemide ) Tablet , Elemental Iron 60 Mg +Folic Acid 500 Mcg, Sugar Coated And Red Color Tablet , Enalapril Tablet 5 Mg , Enema , Enoxaparin Sodium Injection 40Mg / 0.4Ml , Enoxaparin Sodium Injection 60Mg / 0.6Ml , Enoxaprin Sodium Injection 60 Mg In Pfs , Erythromycin Base Tablet 500 Mg , Erythropoietin Inj. 40000 Units / Ml, Single Dose 1 Ml Vial , Escitalopram Tablet 10 Mg , Escitalopram Tablet 5 Mg , Esmolol 10 Ml Vial Injection , Estrogens Cream 0.625 Mg , Ethamsylate Injection 250 Mg / 2 Ml , Ethamsylate Tablet 250 Mg , Ethamsylate Tablet 500 Mg , Ethinyestradiol Tablet 5 Mcg , Etizolam Tablet 0.50 Mg , Etophylline + Theophylline Injection 169.4 Mg + 50.6 Mg / 2 Ml Ampoule , Etophylline + Theophylline Injection 169.4 Mg + 56.6 Mg / 2 Ml , Etophylline + Theophylline Tablet 231 Mg + 69 Mg ( Sr ) , Etoricoxilb Tablet 90 Mg , Favipiravir 200 Mg , Favipiravir 400 Mg , Favipiravir 800 Mg , Fentanyl Injection 50 Mcg / Ml, 2Ml Ampoule , Ferric Carboxymaltoseinjection 500 Mg / Ml , Ferrous ( Iron Sucrose ) Injection 20 Mg / Ml , Ferrous Salt + Folic Acid ( Small ) Tablet ( Enteric Coated ) Equivalent To 20 Mg Iron+100 Mcg Folic Acid, , Ferrous Salt + Folic Acid ( Large ) Tablet ( Enteric Coated ) Equivalent To 100 Mg Iron + 500 Mcg Folic Acid , Ferrous Salt + Folic Acid Tablet ( Enteric Coated ) Equi. To 60 Mg Iron + 500 Mcg Folic Acid ( Red Color ) , Ferrous Salt Tablet Equi. To 100 Mg Elemental Iron , Ferrous Sulpahte + Folic Acid Syrup 100 Mg + 0.5 Mg / 5 Ml, 50 Ml Bottle, Ropp Cap Bottle With Inert Liner & Bottle To Be Provided With A Dispenser To Dispense To 1 Ml Each Time And Packed In A Mono Carton , Fexofenidine + Montelukast 120+10 Mg Tablets , Flavoxate Tablet 200 Mg , Flouromethalone Eye Drops 0.1 % W / V 5Ml , Fluconazole25ml Injection , Fluconazole Capsules 150 Mg , Fluconazole Capsules 200 Mg , Fluconazole Injection 200 Mg / 100 Ml , Flunarazine Tablet 10 Mg , Fluoxetine Capsule 20 Mg , Fluphenazine Injection 25 Mg, 1 Ml Ampoule , Flurbiprofen Eye Drops 0.03% 5Ml , Flurbiprofen Eye Drops 0.03%, 10 Ml Vial , Fluticasone Cream 0.01 % 10Gm , Fluticasone Nesal Spray ( Furamist ) , Fluvir 75 Mg Tablet , Fluvir Injection , Folic Acid Tablet 5Mg , Formalin Solution5 Ltr. , Formocresol Formalin, Cresol Glycerin , Formocresol Formalin Bp 20% V / V , Cresol Ip 32% V / V , Glycerin Ip Qs100 Gm , Framycetin Cream 1%100Gm , Framycetin Cream 1%20Gm , Framycetin Cream 1%, 30 Gm Tube , Furosemide 40 Mg Tablet , Furosemide Injection 10 Mg / Ml, 2Ml Ampoule , Furosemide Tablet 40 Mg , Fusidic Acid Cream 2 % 5 Gm , Fusidic Acid Cream 2 %+ Betamethasone 0.1% W / W , Fusidic Acid Cream 2%, 10Gm Tube , Gabapentin + Nortriptyline ( 400 / 10Mg ) Tablet , Gentamycin + Dexamethasone Eye / Ear Drop 5 Ml Vial , Gentamycin Injection 40 Mg / Ml, 2 Ml Vial , Gliclazide Tablet 40 Mg , Gliclazide Tablet 80 Mg , Glimipride Tablet 1 Mg , Glimipride Tablet 2 Mg , Glucose With Sodium Chloride / Saline Injection 5% Glucose + 0.9% Sodium Chloride 500Ml ( Ffs Bott. ) , Glucose / Dextrose Injection 10% Isotonic 500 Ml ( Ffs Bott. ) , Glucose / Dextrose Injection 25%50Ml , Glucose / Dextrose Injection 5% Isotonic 500Ml ( Ffs Bott. ) , Glutraldehyde Solution 2% - 2.5%, 1 Litre Pack , Glutraldehyde Solution 2.45% 5Ltr. , Glycerine Saline Enema , Glycerine Trinitrate Injection ( Nitro Glycerine ) 5 Mg / Ml , Glycerol85% W / V 100 Ml , Glyceryl Trinitrate ( Niroglycerine ) Injection 5 Mg / Ml, 5 Ml Ampule , Glyceryl Trinitrate ( Sublingual ) Tablet 500 Micrograms , Glyceryl Trinitrate Tablet 0.5 Mg , Glycopyrolate Injection 0.2 Mg / Ml, 1 Ml Ampoule , Haloperidol Injection 5 Mg / Ml , Haloperidol Tablet 5 Mg , Halothane Inhalation 3% To 5% In Oxygen / Nitrous Oxide Maint 0.5 To 1%, 250 Ml , Heparin Lmw Injection 40 Mg / 0.6 Ml , Heparin Lmw Injection 60 Mg / 0.6 Ml , Hepatits B Immunoglobin 0.5Ml Injection , Hepatits B Immunoglobin 1Ml Injection Multidose Vial , Hmf Lactodex Sachet , Homatropine Eye Drops 1%5Ml , Huminsulin 30 / 70Vial ( Regular 30+ Nph 70 ) , Huminsulin 30 / 70 Cartridge ( Regular ) , Hyaluronidase Injection 1500 Iu / Ml1ml ( Sunways ) , Hydrochlorothiazide Tablet 25 Mg , Hydrocortisone ( Sodium Sucinate Powder ) Injection 100 Mg Vial, With 2 Ml Distilled Water For Reconstitution , Hydrogen Peroxide Solution 6%500Ml , Hydroquinone 2.0% W / W + Tretinoin 0.025% W / W+Mometasone Furoate 0.1% W / W In A Cream Base Q.S , Hydroxychloroqunine Tablet 200Mg , Hydroxycobalamin Injection 1 Mg / Ml , Hydroxypropyl Mehtylcellulose Injection 2 %3Ml ( Appasamy ) , Hydroxyzine Syrup 10Mg / 5Ml, 100Ml , Hydroxyzine Tablet 10 Mg , Hydroxyzine Tablet 25 Mg , Hyoscine Butyl Bromide Injection 20 Mg / Ml , Hyoscine Butyl Bromide Tablet 10 Mg , Ibuprofen Oral Solution 100 Mg / 5Ml, 60 Ml , Ibuprofen Tablet 200Mg , Ibuprofen Tablet 400 Mg , Imipenem250 Mg.Injection , Imipenem500 Mg.Injection , Imipenum500mg +Cilastatin 500Mg Injection , Insulinglargine Vial Injection , Insulin ( Soluble ) Injection 40 Iu / Ml In 10 Ml Vial , Insulin Intermediate-Acting Insulin Nph Injection 40 Iu / Ml In 10 Ml Vial , Insuline Lantus 100 Iu / Ml, 10 Ml Vial Injection , Intermediate-Acting Insulin ( Nph ) Injection 40 Iu / Ml In 10 Ml Vial , Ipratropium Respirator Solution For Use In Nebulizer 250Mcg / 1Ml, 2 Ml Respule , Ipratropium Respule 500Mcg 2Ml Injection , Iron Drops 15 Ml , Isoflurane Inhalation 100 Ml Vial , Isolyte P Injection 500Ml ( Ffs Bott. ) , Isopropyl Alcohol Based Handwash Solution 500 Ml ( Gennilium ) , Isopropyl Alcohol I.P. 500 Ml , Isosorbide Dinitrate Tablet ( Sublingual ) 5 Mg , Isosorbide Mononitrate Tablet 20 Mg ( Sr ) , Isosorbide Mononitrate Tablet 30 Mg ( Sr ) , Isosorbide Mononitrate Tablet 5 Mg , Isotretinoin Capsule 20 Mg , Isoxsuprine Injection 5 Mg / Ml , Isoxsuprine Tablet 10 Mg , Ispaghula Granules / Husk / Powder 100 Gm , Itraconazole 200 Mg Cap / Tablet , Ivermectin Tab 06 Mg , Ivermectin Tab 12 Mg , Ivf Hydroxy Ethyl Starch06 Percent 500 Ml , K Y Jelly , Ketaconazole Lotion 2% W / V, 50 Ml , Ketamine ( As Hydrochloride ) Inj. 50 Mg / Ml, 10 Ml Vial , Ketorolac30mg / Ml 1Ml Amp Injection , Kojic Acid Cream 2 % , Labetalol Tablet 100 Mg , Labetolol Injection 20 Gm , Labetolol Injection 5Mg / Ml, 4Ml Amp. , Lactic Acid Bacillus Tablet ( 120M ) , Lactulose Enema 20% W / V 275Ml , Lactulose Solution 10 Gm / 15 Ml, 60 Ml Bottle , Latanoprost Eye Drops 0.005 % W / V, 5 Ml , Leflunomide Tablet 20 Mg , Levetiracetam Syrup 100Mg / Ml , Levetiracetam Tablet500mg , Leviteracitam Injection , Levo Salbutamol 0.63 Mg+Ipratropium Bromide 500Mcg Respule 2.5Ml , Levocetrizine 5 Mg Tablet , Levodopa + Carbidopa Tablet 100 Mg + 10 Mg , Levofloxacin Tablet 500 Mg , Levothyroxine Tablet 50 Mcg , Lidocan Aerosol Spray , Lignocaine 2% ( Xylocard ) 50 Ml Vial Injection , Lignocaine Hydrochloride And Adrenaline Bitartarate Inj. 20Mg / Ml And 0.01Mg / Ml Adrenaline, 30 Ml Vial , Lignocaine Injection ( Heavy ) 2%, 2Ml Vial , Lignocaine Injection 2%, 30 Ml Vial , Lignocaine Injection 4% , 30 Ml Vial , Lignocaine Jelly 2% W / V ( With Seprate Nosal ) , 30Gm Tube , Lignocaine Spray / Viscous 10% , Linezolid600 Mg Tab , Linezolid 600 Mg / 300 Ml Iv Inj. ( 2Mg / Ml ) , Lipid Emuslsion 20 Percent , Liquid Paraffin-3.75Ml + Milk Of Magnesia-11.25Ml, ( Sugar Free ) 225Ml , Lithium Carbonate Tablet 300 Mg , Lorazepam 1 Mg Tablet , Lorazepam 2 Mg Tablet , Lorazepam 2 Mg / Ml Injection , Losartan + Hydrochlorothiazide Tablet ( 50 Mg + 12.5 Mg ) , Losartan Tablet 50 Mg , Magnesium Sulphate Injection 1 Gm / 2Ml ( 50%W / V ) , 2 Ml Ampoule , Mannitol Injectable Solution 20 %, 350 Ml , Mannitol Intravenous Infusion 20% W / V, 100Ml Ffs Technology , Mecobolamine Orally Disintegrating Strip ( Sugar Free ) , Medroxyprogesterone Acetate Inj. Ip ( Dmpa ) 25X1x1ml ( Contraceptive Injection For Im Use Only ) , Medroxyprogesterone Tablet 10 Mg , Mephanamic Acid Syrup 100Mg, 60Ml , Mephenamic Acid + Dicyclomine Tablet 500 Mg +20 Mg , Mephentermine Injection 30 Mg / Ml 10 Ml Vail , Meropenum 125 Mg Injection , Meropenum 250Mg Injection , Meropenum 500 Mg Injection , Mesalamine 1.2 Gm Tablet , Mesalazine Pellets 1Gm ( Abbott ) , Metformin Tablet 1 Gm Sr , Metformin Tablet 500 Mg , Methotrexate Tablet 2.5 Mg , Methotrexate Tablet 7.5Mg , Methyl Ergometrine Injection 200 Mcg In 1 Ml Ampoule , Methyl Ergometrine Tablet 125 Mcg , Methyl Prednisolone Injection 1Gm, 1 Gm Vial With Diluent , Methyl Prednisolone Sod. Succinate Injection 125 Mg Vial , Methyl Prednisolone Sod. Succinate Injection 40 Mg Vial , Methyl Prednisolone Tablet 16 Mg , Methyl Prednisolone Tablet 4 Mg , Methyl Prednisolone Tablet 8 Mg , Methylcobalamin Tablet 1500 Mcg , Methylcobalamine Injection 1500Mcg / 2Ml , Methylcobalamine Tablet 1500Mcg , Methyldopa Tablet 250 Mg , Methyldopa Tablet 500 Mg , Metoclopramide Injection 5 Mg / Ml, 2 Ml Ampoule , Metoclopramide Tablet 10 Mg , Metoprolol Tablet ( Sr ) 50 Mg , Metoprolol Tablet 25 Mg , Metoprolol Tablet 50 Mg , Metronidazole I.V Infusion 5 Mg / Ml, 100 Ml Bottle For Infusion ( Ffs Technology ) , Metronidazole Suspension 200Mg / 5Ml , 60 Ml Bottle , Metronidazole Tablet 200 Mg , Metronidazole Tablet 400 Mg , Micronized Progesterone Tablet 200 Mg , Midazolam Injection 1 Mg / Ml 5 Ml Vail , Midazolam Tablet 15 Mg , Midazolam Tablet 7.5 Mg , Mifepristone Tablet 200 Mg , Milk Of Magnesia +Liquid Paraffin Oral Solution 11.25 Ml + 3.75 Ml / 15 Ml , Misoprostol Tablet 200 Mcg , Mometasone Furoate Cream 0.1 % W / W , Monteleukast Tablet 5 Mg , Morphine Injection 10 Mg / Ml, 1 Ml Ampoule , Mouth Ulcer Gel ( Choline Salicylate Sodium 9% W / V, Benzalkonium Chloride 0.02% W / V ) , 10 Ml , Moxifloxacin + Ketorlac Ear Drops 5 Ml , Moxifloxacin 400 Mg Tablet , Moxifloxacin Eye Drops 0.5% W / V, 5 Ml , Moxifloxacin+ Dexamethasoneeye Drops 0.5% W / V, 5 Ml , Multi Electrolyte Injection ( Isolyte P Multiple Electrolyte & Dextrose In. Type 1 ) , 500 Ml Ffs Bottle , Multi Vitamin Injection 10 Ml Ampoule Iv , Multi Vitamin Syrup With Trace Elements , Multivitamin Drops 15Ml , Multivitamin Drops 25Ml , Mupiricin Ointment 15Gm , Mycothenolate Moftil 500 Mg Tab , Myoforte 360 Mg. Tablet , N Acetyl Cystein ( Nac ) Tablet600mg , Naltrexone Tablet 50 Mg , Naproxen Tablet 250 Mg , Naproxen Tablet 500 Mg , Natamycin Eye Drops 2%, 5 Ml , Nebulizer ( 1 Year Warranty ) , Neosporin -H Oint 20 Gms , Neostigmin Injection 2.5Mg / 5 Ml Ampoule , Neostigmine Injection 500 Mcg / Ml ( 0.5Mg / Ml ) 1 Ml Ampoule , Neosure Milk Powder , Netilmycin Injection , Nicotin Chewgum 2 Mg , Nicotin Chewgum 4 Mg , Nifedipine Capsule ( Sublingual ) 5 Mg , Nifedipine Tablet Ip Sr / Er 10 Mg , Nitazoxanide Tablet 500 Mg , Nitrazepam 10 Mg Tablet , Nitrofurantoin Tablet 100 Mg , Nitroglycerine 2.6 Mg Tablet , Nitrous Oxide Inhalation , Noradrenaline Injection 4Mg / 2Ml , Norethisterone Tablet 5 Mg , Normal Saline ( Sodium Chloride ) Injection 0.9% Isotonic, 100Ml ( Ffs ) , Normal Saline ( Sodium Chloride ) Injection 0.9% W / V, 500 Ml Bottle ( Ffs Technology ) , Normal Saline Injection 3% 100 Ml , Ofloxacin + Prednsolone Eye Drops 5 Ml. , Ofloxacin 100 Mll Infusion , Ofloxacin Syrup 50Mg / 5 Ml, 60 Ml , Ofloxacin Tablet 200 Mg , Olanzapine Injection , Olanzapine Tablet 10Mg , Olanzapine Tablet 5 Mg , Olmesartan 20 Mg + Amlodipine 5 Mg + Hydrochlorothiazide 12.5 Tablet , Olopatadine 0.1% Eye Drops 5 Ml , Olopatadine Eye Drops , Omeprazole Capsule 20 Mg , Ondansetron Injection 2Mg / Ml , 2Ml Ampoule , Ondansetron Oral Liquid 2 Mg / 5 Ml , Ondansetron Tablet 4 Mg , Ondansetron Tablet 8 Mg , Oral Glucose 100 Gm , Oral Glucose 1000 Gm , Oral Glucose 200 Gm , Oral Glucose 500 Gm , Oral Glucose 75 Gm , Oral Rehydration Salts Powder For 1000 Ml Solution , Oral Rehydration Salts Powder For 200 Ml Solution , Oxygen ( Medicinal Gas ) Inhalation , Oxytocin Injection 5 Iu In 1 Ml Ampoule , Pangoaf 0.25 Mg.Tablet , Pangoaf 0.5 Mg.Tablet , Pantoprazole + Domperidone Sr ( 40Mg+30Mg ) Capsule , Pantoprazole Injection 40 Mg, Vial With 10 Ml Diluent , Paracetamol 100 Ml Iv. Infusion , Paracetamol Drops 150Mg / Ml, 10 Ml Vial With Marked Dropper , Paracetamol Infusion 100 Mg / 5 Ml , Paracetamol Injection 150 Mg / Ml, 2 Ml Amp. , Paracetamol Peadiatric Syrup 125Mg / 5Ml, 60 Ml Bottle , Paracetamol Tablet 500 Mg , Paracetamol Tablet 650 Mg , Paraldehyde Solution For Sterlization , Paroxetine ( Cr ) Tablet 25Mg , Pds 4-0 Round Body , Pds On Loop 1 No. , Pentaprazole Capsule 20 Mg , Pentaprazole Capsule 20 Mg + Domperidon 10 Mg , Pentaprazole Injction 40 Mg , Pentazocine Injection 30 Mg / Ml, 1 Ml Ampoule , Permethrin Lotion 5%, 50 Ml , Pethidine Injection 50 Mg / Ml, 1Ml Ampoule , Pharma Cresol , Pheniramine Maleate Injection 22.75 Mg / Ml, 2 Ml , Phenobarbitone Injection 200 Mg / Ml , Phenobarbitone Oral Solution 20 Mg / 5 Ml, 60 Ml Bottle , Phenobarbitone Tablet 60 Mg , Phenylephrine Hcl+Pcm + Cpm +Caffine Anti Cold Syrup 60 Ml , Phenylephrine Hcl+Pcm + Cpm +Caffine Anti Cold Tablet , Phenytoin ( Sodium ) Injection 100Mg, 2Ml Amp. , Phenytoin Oral Solution 25 Mg / Ml, 100 Ml Glass Bottle , Phenytoin Tablet 100 Mg , Phenytoin Tablet 300 Mg , Phytomenadion 1Mg / 0.5 Ml ( Vitamin -K ) Injection , Pilocarpine Eye Drops 2 % 5Ml , Pilocarpine Nitrate 0.5% W / V Injection 1Ml Ampoule , Pipracillin+Tazobactim 1.125 Gm Injection , Pipracillin+Tazobactim 4.5 Gm Injection , Plasma Volume Expander Injection ( Each 100 Ml Contains Polygeline, Polypeptides Of Degaraded Gelatin, Cross Linked Via Urea Bridges 3.5 G ( Equivalent To 0.63 G Of Nitrogen ) Nacl Ip 0.85 G, Kcl Ip 0.038 G Cacl2 Ip 0.070G Water For Injection Ip Q.S Electrolytes In M.Mol / Litre, 500 Ml Ffs , Plaster Of Paris Bandages B.P 10 Cm X 2.7 Mtrs , Plaster Of Paris Bandages B.P 15 Cm X 2.7 Mtrs , Podophylline Resin Solution 10% To 25% , Posacanazole 100 Mg Gastro-Resistant Tablet , Posacanazole 300 Mg Gastro-Resistant Tablet , Potassium Chloride ( Solution ) Injectable 15% ( 150Mg / Ml ) , 10 Ml Amp. , Potassium Chloride Oral Liquid 500 Mg / 5 Ml , Potassium Chloride Oral Solution 10%, 100 Ml Bottle , Potassium Chloride Solution 20%473Ml. , Potassium Permanganate Crystal For Solution 100 Gm , Potassium Peroxymonosulfate, Sodium Decylbenzenesulfonate, Sulfamic Acid, , Povidone Iodine 5% Eye Drops , Povidone Iodine Ointment 5%, 250Gm , Povidone Iodine Ointment 5%, 15 Gm , Povidone Iodine Scrub ( Povidone Iodine Cleansing Solution 7.5 %, W / V With Foaming Agent ) 500 Ml , Povidone Iodine Solution 10%, 500 Ml , Povidone Iodine Solution 5% , 2 Lts , Pralidoxime ( Pam ) Injection 1 G Vial , Prednisolone Sodium Phosphate Eye Drops 1% 5Ml , Prednisolone Tablet 10 Mg , Prednisolone Tablet 20 Mg , Prednisolone Tablet 40 Mg , Pregabalin 75 Mg+ Methylcobalamin 750 Mcg Tablet , Prochlorperazine Mouth Dissolving Tablet Flavored Base 5Mg , Progesterone Tablet 100 Mg , Promethazine ( Hydrochloride ) Elixir Or Syrup 5 Mg / 5 Ml, 60 Ml Bottle , Promethazine Injection 25 Mg / Ml, 2 Ml Amp , Propofol Injection 1% Vial ( 10 Mg / Ml , 10 Ml Vial ) , Propranol Tablet 20 Mg , Propranolol Tablet ( Sr ) 40 Mg , Propranolol Tablet 10 Mg , Prostadin 2 Ml Amp Injection , Protamine Sulphate ( Heparin Antagonist ) Injection 10 Mg / Ml, 5-Ml Ampoule , Purified Freeze – Dried Human Coagulation Factor Viii, Virus Inactivated Injection 250 Iu , Purified Freeze Dried Human Coagulation Factor Ix, Virus Inactivated / Anti Hemophillic Factor Ix Injection 600Iu , Pyridoxine Tablet 10 Mg , Pyridoxine Tablet 100 Mg , Photothreapy Machine With Led , Quetiapine Tablet 100 Mg , Quetiapine Tablet 50 Mg , Rabeprazole 20 Mg & Levosulpiride 75 Mg Capsule , Rabies Vaccine Single Dose Rabies Vaccine 2.5 Iu Injection For Human Use Prepared In Chick Embryo / Vero Cell / Human Diploid Culture Single Dose With Diluent And Disposable Syringe With Needle , Radiant Warmer / Baby Warmer Led Type , Ramipril Tablet 5 Mg , Ranitidine Injection 25 Mg / Ml, 2 Ml Amp , Ranitidine Syrup 150 Mg / 10 Ml , Ranitidine Tablet 150 Mg , Ranolazine Tablet 500Mg , Ringer Lactate ( Solution ) For Injection ( Compound Sodium Lactate ) 500 Ml Ffs Bottle , Ringer Lactate Injection 500Ml ( Glass Bottle ) , Risperidone Tablet 1 Mg , Risperidone Tablet 2 Mg , Risperidone Tablet 4 Mg , Rosuvastatin 10 Mg+ Fenofibrates 160 Mg Tablet , Saccharomyces Boulardii 5 Cfu Sachets , Salbutamol Inhaler Areosol 100 Microgram / Dose, Mdi, Single Packing , Salbutamol Nebulizer / Respirator Solution 5 Mg / Ml 15 Ml , Salbutamol Syrup 2 Mg / 5 Ml, 100 Ml Bottle , Salbutamol Tablet 4 Mg , Salicylic Acid Ointment 6% , Saline Nasal Drops 0.6% 10 Ml , Sanitary Napkin , Savlon Lotion 500 Ml , Serrapiopeptibase 10 Mg Tablet , Sertaconazole Cream 2% W / W, 15 Gm , Sertraline ( Sr ) Tablet ( Sr ) 50 Mg , Sertraline Tablet 100 Mg , Sevelamer Carbonate Tablet 400 Mg , Sevoflurane Inhalation 250 Ml , Sildenrfiltablet 25 Mg , Sildenrfiltablet 50 Mg , Sildenrfiltablet 75Mg , Silver Sulfadiazine Cream 1%20Gm , Silver Sulfadiazine Cream 1%250Gm , Silver Sulfadiazine Cream 1%, 30 Gm Tube , Sodium Bicarbonate Injection 7.5 % 10 Ml , Sodium Bicarbonate Injection 7.5%25Ml , Sodium Bicarbonate Tablet 500Mg , Sodium Carboxymethyl Cellulose Eye Drops 0.5%W / V10ml , Sodium Chloride Topical Eye Drops 6% W / W, 5 Ml , Sodium Hypochlorite Solution 10% , Sodium Valporate Injection 100Mg / Ml, 5Ml , Sodium Valproate Oral Liquid 200 Mg / 5 Ml , Sodium Valproate / Valproic Acid ( Sodium ) Cr Tablet 300 Mg , Sodium Valproate / Valproic Acid Enteric Coated Tablet 200 Mg , Sodium Valproate / Valproic Acid Enteric Coated Tablet 500 Mg , Spacer For Meter Dose Inhaler , Spironolactone Tablet 25 Mg , Sterilum ( Hand Wash ) 500 Ml , Streptokinase Injection Powder 1500000 Iu , Succinyl Choline Injection 50 Mg / Ml , Sucralfate 1Gm With Oxetacain 10Mg / 10Ml Suspension , Sucralfate Suspension 10Mg / 5Ml Suspension 200Ml , Sucrose ( Iron Sucrose 20Mg ) Injection 20 Mg / Ml, 5Ml Ampoule , Sulfasalazine Tablet 500 Mg , Surgical Spirit500 Ml , Survanta / Curosurf / Neosurf Injection , Suture Absorbable Surgical Suture Usp ( Catgut-Chromic ) 76 Cm X 30 Mm, Size 1, ½ Circle R.B. Heavy Needle , Suture Absorbable Surgical Suture Usp ( Catgut-Chromic ) 76 Cm X 30 Mm, Size 1-0, ½ Circle R.B. Needle , Suture Absorbable Surgical Suture Usp ( Catgut-Chromic ) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle , Suture Absorbable Surgical Suture Usp ( Synthetic ) Polyglactin 910 Braided Coated With Triclosan Antibaterial 90 Cm X 40 Mm, Size -1, ½ Circle R.B. Heavy Needle , Suture Absorbable Surgical Suture Usp ( Synthetic ) Polyglactin 910 Braided Coated With Triclosan Antibaterial 90 Cm X 40 Mm, Size 1-0, ½ Circle R.B. Needle , Suture Catgut ( Chromic Catgut ) Usp 1, 76 Cm X 63 Mm, 3 / 8 Circle ( 12 Foils In Each Box ) , Suture Needle Pack Of Six ( Size 0-6 , All Size ) , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) 76 Cm X 45 Mm, Size -1, 3 / 8 Circle Reverse Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) 76 Cm X 45 Mm, Size -2-0, 3 / 8 Circle Reverse Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) 76 Cm X 45Mm, Size -1-0, 3 / 8 Circle Reverse Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) 90 Cm X 16Mm, Size -3-0, 3 / 8 Round Bodyneedle , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) 90 Cm X 16Mm, Size -3-0, 3 / 8 Circle Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) Sutu Pack ( 2X75 ) Size1 , Suture Non-Absorbable Surgical Suture Usp ( Braided Silk Black ) Sutu Pack ( 2X75 ) Size1-0 , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 100 Cm X 45 Mm, Size -1, ½ Circle Reverse Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 45 Cm X 25 Mm, Size -3-0, ½ Circle R B Needle , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 45 Cm X 25 Mm, Size -3-0, 3 / 8 Circle Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 60 Cm X 16 Mm, Size -4-0, 3 / 8 Circle Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 70 Cm X 25 Mm, Size -2-0, ½ Circle Tapper Cutting Needle , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 70 Cm X 40 Mm, Size -1, ½ Circle R B Heavy Needle , Suture Non-Absorbable Surgical Suture Usp ( Polypropylene Monofilament Suture ) 90Cm X 30Mm, Size -1-0, ½ Circle Tapper Cutting Heavy Needle , Suture Polyglactin ( Plain ) Vicryl Usp-0, 90 Cm X 30 Mm, 1 / 2 Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polyglactin ( Plain ) Vicryl Usp-1, 90 Cm X 40 Mm, 1 / 2 Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polyglactin ( Plain ) Vicryl Usp-2-0, 70 Cm X 20 Mm, 1 / 2 Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polyglactin ( Plain ) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1 / 2 Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polyglactin ( Plain ) Vicryl Usp-4-0, 70 Cm X 20 Mm, 1 / 2 Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1 / 2 Circle, Type Of Needle- Oval Round Body ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1 / 2 Circle, Type Of Needle- Round Body Medium Half Circle ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / Ethicon / B Brouwn / Covedion / , Suture Polymide Sutureusp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / Ethicon / B Brouwn / Covedion / , Suture Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3 / 8Circle Type Of Needle- Reverse Cutting ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Polypropylene Sutureusp -1, 70 Cm X 40 Mm, 1 / 2 Circle Type Of Needle- Heavy Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / Ethicon / B Brouwn / Comedion / , Suture Polypropylene Sutureusp -2-0, 90 Cm X 30 Mm, 1 / 2 Circle Type Of Needle- Round Bodied ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Prolene 3-0 , Suture Prolene Suture 3.0, Rc , Suture Prolene Suture 4.0 Rc , Suture Silk Sutupak Usp 1, 75 Cm ( 12 Foils In Each Box ) Jonshun & Johnshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Silk Sutureusp 0, 76Cm X 45 Mm , 3 / 8 Circle Type Of Needle- Reverse Cutting ( 12 Foils In Each Box ) Jonshun & Jonshun / Piter Surgical / Suture India / Ethicon / B Brouwn / Comedion / , Suture Silk Sutureusp 2-0, 90 Cm X 16 Mm , Round Body Needle ( 12 Foils In Each Box ) Jonshun & Jonshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Silk Sutureusp 3-0, 90 Cm X 16 Mm , Round Body Needle ( 12 Foils In Each Box ) Jonshun & Jonshun / Piter Surgical / Suture India / B Brouwn / Comedion / , Suture Vicryl 10-0 , Suture Vikryl Suture 3.0 , Suture Vikryl Suture 4.0 Rc , Tacrolimus 0.25 Gm Tab , Tacrolimus 0.5 Gm Tab , Tacrolimus 1 Gm Tab , Tacrolimus Ointment 0.03% W / W, 10 Gm , Tamsulosin Tablet 0.4 Mg , Tamsulosin Tablet 0.4 Mg + Dutasteride Tablet 0.5 Mg , Telmisartan Tablet 40 Mg , Telmisartan Tablet 80 Mg , Teneligliptin Film Coated Tablet 20 Mg , Teneligliptin Tablet 20Mg , Terbinafine Cream 30Gm , Terlipression 1Mg / 10 Ml Injection , Tetanus Toxoid Injection 0.5 Ml Ampoule , Tetanus Toxoid Injection 5 Ml Vial , Thiamine Injection 100 Mg / Ml, 2 Ml Vial , Thiamine Tablet 100 Mg , Thiocolchicoside Tablet 4 Mg , Thiopentone Injection Powder 0.5 G , Thyroxine Tablet 50 Mcg , Timolol Eye Drops 0.5%, 5Ml , Tinidazole Tablet 500 Mg , Tobramycin Opthalmic Solution 0.3% W / V, 5Ml , Torasemide Tablet 10 Mg , Total Parentral Nutrition ( Tpn ) 1440Ml Injection , Tramadol Hydrochloride Capsule 100 Mg , Tramadol Hydrochloride Capsule 50 Mg , Tramadol Injection 50 Mg / Ml, 2 Ml Ampoule , Tranexamic Acid 500 Mg + Mefenamic Acid 250 Mg Tablet , Tranexamic Acid Injection 500 Mg / 5 Ml , Tranexamic Acid Tablet 500 Mg , Tranexamic Acid Tablet 500 Mg + Mefenamic Acid 500 Mg , Triamcinolone Injection 20 Mg / Ml , Triamcinolone Injection 40 Mg / Ml , Trifluperazine 5 Mg Tablet , Trihexyphenidyl ( Hydrochloride ) Tablet 2 Mg , Tropicamide + Phenylepherine Eye Drops 0.8% + 5% 5Ml , Tryptan Blue Dye1ml ( Aurolab ) , Ursodeoxycholic Acid 150Mg Tablet , Ursodeoxycholic Acid 300Mg Tablet , Valethemate Injection 8 Mg / Ml , Vancomycin 250 Mg. Injection , Vancomycin 500 Mg. Injection , Vasopressin Injection 20 Units / Ml , Vecuronium Injection 10 Mg Vial , Vecuronium Injection 2 Mg / Ml, Dry Powder , Venlafaxine Capsule 37.5 Mg , Vildagliptin Tablet 5Mg , Vitamin A Oral Solution 100000 Iu / Ml, 100 Ml , Vitamin D3 Drops 400 Iu / Ml , Vitamin D3 Tablet ( Chewable ) 60000Iu , Vitamine B1, B6, B12 Injection 3 Ml , Voglibose 0.3 Mg , Voglibose 0.3 Mg + Metformin 500Mg+ Glimipride 1 Mg Tablet , Varneciline 1 Mg Tablet , Varneciline 0.5 Mg Tablet , Water For Injection 100 Ml Ampoule , Water For Injection 10Ml Ampoule , Water For Injection 5Ml Ampoule , Wax Dissolving Ear Drops ( Paradichlorbenzene 2% W / V, Benzocain 2.7 % W / V, Chlorbutol 5% W / V, Turpentine Oil 15% Ear Drops ) , 10 Ml , White Petrolatum Jelly 100 %, 50 Gm Jar , Xylocard50 Ml Injection , Xylometazoline Nasal Drops 0.05 %, 10 Ml , Xylometazoline Nasal Drops 0.1 %, 10 Ml , Zig Zag Cotton 100 Gm , Zinc ( Sulphate ) Dispersible Tablet 20 Mg , Zinc Drops 15Ml , Zinc Tablet 20 Mg , Ziprasidon 40 Mg Capsules / Tablet ( Zypsidon 40 Mg Caps. ) , Zolpidem 5 Mg Tablet , Tuberculosis Medicines , Clofazimine 100 Mg Tablet , Clofazimine 50 Mg Tablet , Cycloserine 250 Mg Tablet , Cycloserine 500 Mg Tablet , Ethambutol 400 Mg Tablet , Ethambutol 800 Mg Tablet , Ethionamide 500 Mg Tablet , Levofloxacin 250 Mg Tablet , Levofloxacin 500 Mg Tablet , Linezolid 300 Mg Tablet , Linezolid 600 Mg Tablet , Moxifloxacin 400 Mg Tablet , Pyrazinamide 500 Mg Tablet , Pyrazinamide 750 Mg Tablet , Pyridoxine 100 Mg Tablet , Pyridoxine 50 Mg Tablet , Rifampicin150 Mg Capsule , Rifampicin300 Mg Capsule , Rifampicin 450 Mg Capsule , Rifampicin 600 Mg Capsule , Ab Gel ( Shri Krishna ) , Abdominal Drain 20 , Abdominal Drain 22 , Abdominal Drain 24 , Abdominal Drain 28 , Adhesive Plaster 10Cmx5mtrs , Adhesive Plaster 7.5Cmx5mtrs , Air Mattress , Airway Set Size 2 , Airway Set Size 3 , Airway Set Size 4 , Airway Set Size 5 , Ambu Bag Adult , Ambu Bag Paed. , Anterior Chamber Kellmann Multi Flex 4 Point Fixation Type Optical Diameter 6 Mm, Overall Length 12.5 Mm, Dioptic Range 10D To 30 D , Agfa Cr Film ( Dt2b ) ( 1X100 ) 8X10 , Agfa Cr Film ( Dt2b ) ( 1X100 ) 10X12 , Agfa Cr Film ( Dt2b ) ( 1X100 ) 11X14 , Agfa Cr Film ( Dt2b ) ( 1X100 ) 14X17 , Balance Salt Regulator Extensionsets , Bb Splint ( Bohler- Braun ) , Bed Side Pulley , Bio Medical Waste Poly Bag Different Color And Size Per Kg , Blades For Eye Surgery Crescent , Blades For Eye Surgery Extension 5.2 Mm , Blades For Eye Surgery Keratones 2.8 M , Blades For Eye Surgery Side Port 15° , Blades For Eye Surgery Keratones 3.2 Mm , Blood Filter Set , Carner Wire Splint , Centre Line , Chest Drainag Bag , Chest Drainag Catheter No.12 , Chest Drainag Catheter No.14 , Chest Drainag Catheter No.32 , Chest Drainag Catheter No.16 , Cervical Coller Soft Small Size , Cervical Coller Soft Medium Size , Cervical Coller Soft Large Size , Cervical Coller Hard Universalsize , Cord Clamp Steril, Non Toxic, Pyrogen Free Sterile Use Only Single Unit Packing. , Courtery Lead Pencil ( Single Unit ) , Courtery Pad ( Single Unit ) , Cusco Specullum Large Size S.S. Superior Quality 304 / 316 , Dark Glasses , Dhl X-Ray8x10 ( Fugi Film ) , Dianaplaster ( 10Cmx4.6Mtrs ) , Diaper Paediatric Teddy ( Extra Small Size For Neonates ) , Dispoable Surgical Glovesisi Mark 6.0 No. , Dispoable Surgical Glovesisi Mark 6.5 No. , Dispoable Surgical Glovesisi Mark 7 No. , Dispoable Surgical Glovesisi Mark 7.5 No. , Dispoable Surgical Gloves Isi Mark 8 No. , Disposable Adhesive Cannula Fixator Relifix , Disposable Bed Sheet-42 Gsm Sheet, Size 60X78 , Disposable Cap , Disposable Eye Patch , Disposablesyringe Insulin 1 Ml 26 Needle , Disposable Mask , Disposable Mask Triple Layers , Disposable Needleno ( 16, 18, 20 ) Sizes , Disposable Needleno ( 22, 23, 24 ) Sizes , Disposable Needleno ( 26 ) Sizes , Disposable Pillow Cover-42 Gsm Sheet, Size 21X30 , Disposable Plastic Bed Pan , Disposable Plastic Urine Pan , Disposable Shoe Cover , Disposable Sterile Powder Free Gloves For Eye Surgeries, 6.0 Isi Mark , Disposable Sterile Powder Free Gloves For Eye Surgeries, 6.5 Isi Mark , Disposable Sterile Powder Free Gloves For Eye Surgeries, 7.0 Isi Mark , Disposable Sterile Powder Free Gloves For Eye Surgeries, 7.5 Isi Mark , Disposable Sterile Powder Free Gloves For Eye Surgeries, 8.0 Isi Mark , Disposable Syringes 1 Ml ( 23G ) , Disposable Syringes 2 Ml, ( 23G ) , Disposable Syringes 2 Ml, ( 24G ) With Needle , Disposable Syringes 5 Ml, ( 23G ) With Needle , Disposable Syringes 5 Ml, ( 24G ) With Needle , Disposable Syringes- 10 Ml. With Needle 23 G , Disposable Syringe 20Ml , Disposable Syringe 50Ml , Dj Stunt No. 5 , Dj Stunt No. 6 French End Closed , Ecg Electrodes ( Disposable Kit ) Pack Of 6 , Ecg Jelly 250 Ml , Ecg Paper 215 Mm*20 Mtr , Ecg Paper 50 Mm*20 Mtr , Ecg Paper 50 Mm*30 Mtr , Ecg Paper 60 Mm* 15 Mtr , Ecg Roll Big A4 Paper Size , Ecg Roll Small Size , Endotrocheal Tube 2.5 Uncuffed , Endotrocheal Tube 3 Uncuffed , Endotrocheal Tube 3.5 Uncuffed , Endotrocheal Tube 4 Uncuffed , Endotrocheal Tube 4.5 Cuffed , Endotrocheal Tube 4.5 Uncuffed , Endotrocheal Tube 5 Cuffed , Endotrocheal Tube 5 Non-Cuffed , Endotrocheal Tube 6 Cuffed , Endotrocheal Tube 6.5 Cuffed , Endotrocheal Tube 7 Cuffed , Endotrocheal Tube 7.5 Cuffed , Endotrocheal Tube 8 Cuffed , Endotrocheal Tube 8.5 Cuffed , Epidural Set , Examination Gloves 5 Gm Eachisi Surgicare / Kaltax ( All Size ) ( Box Of 100 Pcs ) , Nitryl Gloves All Sizes Isi ( Surgicare / Kaltax ) ( Box Of 100 Pcs ) , Foleys Catheter 8 Fg , Foleys Catheter10 Fg , Foleys Catheter 14 Fg , Foleys Catheter 16 Fg , Foleys Catheter 18 Fg , Fuji X-Ray Films ( 1X50 ) 8X10 , Fuji X-Ray Films ( 1X50 ) 10X12 , Fuji X-Ray Films ( 1X50 ) 11X14 , Fuji X-Ray Films ( 1X50 ) 12X15 , Fuji X-Ray Films ( 1X50 ) 14X17 , Green Blade For Eye , Guide Wire Teflon Coated J Tip , Guide Wire Teflon Coated V Straight Tip , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 15.5 Cm X 8.5Cm ( Pack Of 100 ) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 25 Cm X 10 Cm , ( Pack Of 100 ) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 6.5 Cm X 5 Cm ( Pack Of 100 ) , Hernia Meshmacroporous Polypropylene ) 7.5 Cm X 15 Cm Ovalfor Lap Of Hernia , Hi Concentration Mask / Nrm Mask ( Paediatric / Adult ) , Hiv Safe Kit ( Protection Gown, Surgeon Cap, Surgeon Mask, Pair Of Latex Gloves, Pair Of Shoe Cover, Goggles, Waste Carry Bag ) Iso / Ce Marked , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System, Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range 10 D To 25 D , Hydrophobic Acrylic Non Foldable Iols In Preloaded Delivery System, Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range 10 D To 25 D , I.O Dye ( Rhex Id Dye ) Each ( Indigo Blue Dye ) , I.V. Canulas 16 With Luer Lock , I.V. Canulas 18With Luer Lock , I.V. Canulas 20 With Luer Lock , I.V. Canulas 22 With Luer Lock , I.V. Canulas 24 With Luer Lock , I.V. Canulas 26 With Luer Lock , I.V.Sets Disposable Non Vented , I.V.Sets Disposable Vented , Infant Feeding Tube 4, 5, 6, 8, 10 No. , Insulin Pen Needle 32G 0.23Mm , Insulin U-100 Syring , Insulin U-40 Syring , Iopa X - Ray Films , Karman / Mtp Cannula No. 6 , Karman / Mtp Cannula No. 7 , Karman / Mtp Cannula No. 8 , Laproscopic Bipolar Hand Instrunment , Lega Clipsize Lt 300 ( Titanium Clips Medium Size Having Lateral And Transverse Grooves On The Inner Clip ) , , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone15 Cm X 15 Cm ( 3 Foils In Each Box ) , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone6 Cm X 11 Cm ( 3 Foils In Each Box ) , Merocele Nesal Packing , Micropore / Surgical Paper Tape 25 Mm X 9.1Mtr. , Micropore / Surgical Paper Tape 50 Mm X 9.1 Mtr. , Micropore / Surgical Paper Tape 75 Mm X 9.1 Mtr. , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port, Size 5X6 Cm , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port, Size 7X9 Cm , Mr Cannula No. 5 , Mr Cannula No. 6 , Mr Cannula No. 7 , Mr Cannula No. 8 , Mr Syringe , Mucous Suction Trap / Mucus Extractor , Multilayer Tissue Seprating Polyglecaprone Mesh ( Polydioxanone And Macroporous Polypropylene ) 10Cm X 15 Cm Oval ( 1 Foil In Each Box ) For Lap Of Hernia , Multilayer Tissue Seprating Polyglecaprone Mesh ( Polydioxanone And Macroporous Polypropylene ) 15Cm X 15 Cm Square ( 1 Foil In Each Box ) For Lap Of Hernia , Mva Syringe , N1h1 Swine Flu Test Kit + Swab , N-95 Masks 3M , N-95 Masks Venus , Nebulisation Set ( Mask With Tubing With Chamber ( Adult ) , Nebulisation Set ( Mask With Tubing With Chamber ( Paediatric ) , Negative Suction Catheter All Sizes , Negative Suction Drain / Wound Suction Set ( All Size ) , Operation Site Drape Sheet 70 Cm *80 Cm , Ortho Pthaldehyde0.55% ( Sanidex-Opa ) , Oxygen Set Neonatal , Oxygen -Mask ( Pvc / Disposable ) Adult , Oxygen -Mask ( Pvc / Disposable ) Medium , Oxygen -Mask ( Pvc / Disposable ) Paed. , Oxygen Venti-Mask ( Pvc / Disposable ) Adult , Oxygen Venti-Mask ( Pvc / Disposable ) Medium , Oxygen Venti-Mask ( Pvc / Disposable ) Paed. , Ot Sponge With Radio- Opaque Thread ( With 8 Layers 30 Cm X30 Cm ) , Partial Absorble ( 10X6 Cm ) Vicryl Mesh For Ipom , Patient Identification Bandadult Size ( Different Colours ) , Patient Identification Band Paediatric Size ( Different Colours ) , Pedia Drip Set ( Romsons ) , Pmo Line ( Romson ) 100 / 200Cm , Posterior Chamber Pmma Iol, Optical Diameter 5.25Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D , Posterior Chamber Pmma Iol, Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D , Potassium Peroxomono Sulphate 50% ( Sanimax ) , Ppe Kits ( One Disposable Gown, One Pair Of Gloves, A Face Shield, Cap, Shoe Cover, N-95 Mask , Ared Bag Acopy Of Ppe Placement And Removal Posters Iso / Ce Marked , Pre Powdered Disposable Surgical Gloves 6.0Surgicare ( I.S.I And Ce ) , Pre Powdered Disposable Surgical Gloves 6.5 Surgicare ( I.S.I And Ce ) , Pre Powdered Disposable Surgical Gloves 7.0 Surgicare ( I.S.I And Ce ) , Pre Powdered Disposable Surgical Gloves 7.5 Surgicare ( I.S.I And Ce ) , Pre Powdered Disposable Surgical Gloves8.0 Surgicare ( I.S.I And Ce ) , Prolene Mesh ( 15×15Cm ) , Pouch Arm Sling Standard , Parafilm , Ryles Tube All Nos , Room Heater Electric ( Maharaja ) , Room Heater Oil Filled , Satinsky Clamp 10-1 / 4 Angled , Serrated Ss, Reusable Non Sterile , Latex Free Premium Or - Grade- Hemostatic Forceps , Skin Stapler Standard Quality , Skin Traction Set Standard Size , Skeletal Traction , Shoulder Immobilizer Standrad , Soft Roll Dressing ( Cast Padding ) 4 , Soft Roll Dressing ( Cast Padding ) 6 , Spinal Needle 23, 24, 25, 26 ( For Single Usegx31 / 2Inch Clear / Transparent Hub ) , Suprapubic Catheter Set ( Spc ) , Suctioncatheter ( All Size ) , Surgical Blades11 ( Pack Of 100 ) Isi / Ce Marked , Surgical Blades12 ( Pack Of 100 ) Isi / Ce Marked , Surgical Blades15 ( Pack Of 100 ) Isi / Ce Marked , Surgical Blades20 ( Pack Of 100 ) Isi / Ce Marked , Surgical Blade 23 ( Pack Of 100 ) Isi / Ce Marked , Surgical Blades24 ( Pack Of 100 ) Isi / Ce Marked , Tegadrum 3M 1680 , Three Way Cannula , Tropinin Kit , Turp Loop , Ultrasound Jelly 250 Ml Bottle , Umblical Tape1 / 4 X 36 Sterile, Non Absorable Surgical Cotton , Urine Bag 2000 Ml Single Unit Packing , Vasular Tissue Forceps 6 , X-Ray Films ( 1X50 ) 10X12 , X-Ray Films ( 1X50 ) 11X14 , X-Ray Films ( 1X50 ) 12X15 , X-Ray Films ( 1X50 ) 14X17. , X-Ray Films ( 1X50 ) 8X10 , Yankursuction Set. , Allis Forceps 8” Long With Tip 4 Mm Wide ( Ss / 304 Min. ) , Autoclave Drum Large ( Steel Grade 304 ) ( 12*15 Inch ) , Autoclave Drum Medium ( Steel Grade 304 ) ( 9*9 Inch ) , Autoclave Drum Small ( Steel Grade 304 ) ( 9*11 Inch ) , Autoclave Drum Small ( Steel Grade 304 ) ( 10*12 Inch ) , B.P.Apparatus Aneroid / Dial Isi Mark ( Dimond / Bpl ) , B.P.Apparatus Digital Isi Mark ( Bpl / Omron / Beurer ) , B.P.Apparatus Led Type Isi Mark ( Diamond ) , Bp Apparatus Led Standing ( Diamond ) , Bp Apparatus Clock Standing ( Diamond ) , Babcock ( 8” Long ) ( Ss / 304 Min. ) , Baby Weighing Machine Digital ( Easy Care / Suvrna / Perfaxa ) Table Top, Light And Portable. Built In Rechargeable Battery. Easy To Clean Baby Tray ( Acrylic ) . Zero Weight Adjustment Facility. Quick, Clear Digital Read Outs. Measurement Does Not Change With Position Of Baby On The Pan. Provision To Measure The Height Of The Baby In Its Laying Position. Accuracy: 5G, Resolution: 1G, Limit: 10Gm To 15Kg , Bench Top Centrifuge ( Table Top Centrifuge ) , Bio Medical Waste Bin 10 Litres Capacity Superior Quality Plastic No.1 , Bio Medical Waste Bin 25 Litres Capacity Superior Quality Plastic No.1 , Bio Medical Waste Bin 40 Litres Capacity Superior Quality Plastic No.1 , Bio Medical Waste Poly Bag Different Color And Size Per Kg , Biomedical Trolly Curved ( Bharat / Aone ) , Bio-Medical Waste Trolley: 4 Bin Capcity, Coaster Wheel, Foot Operated Peddle, All Stainless Steel, Separate Buckets Provided 25 Ltr. Capacity Of Each Bin ( Bharat / Aone ) , Centrifuge Machine: Without Carbon Multi-Spin, Automatic, Averagely Collecting 12 Tubes At A Time, Spin Regulation:1000- 3500 Rpm, Spintime: 1Sec-99Min ( Alpine ) , Chitel Forcep S.S. Superior Quality ( 304 Grade ) , Co2 Fire Extinguishers ( 3 K.G ) : Capacity3 Kg, Fire Rating70db, Test Pressure ( Bar ) 250 Working Pressure Bar 166, Temp Range-300C To 600C, Discharge Time 9Second Total Weight 4.0 K.G, Height 317Mm, Cylinder Dia 110 Mm, Extinguishing Agent Co2, Packing Dimension 135X115x390 Mm , Co2 Fire Extinguishers ( 5 K.G ) : Capacity 5.2 Kg, Fire Rating70db, Test Pressure ( Bar ) 250 Working Pressure Bar 166, Temp Range-300C To 600C, Discharge Time 9Second Total Weight 4.0 K.G, Height 317Mm, Cylinder Dia 110 Mm, Extinguishing Agent Co2, Packing Dimension 135X115x390 Mm , Coldstoragebox: 1, Usable Capacity 8-10 Ltrs. 2, Should Be Able To Accommodate Min. 2 Boxes Of Size240 Mm X145mmx80mm.3, Empty Capacity: 15 Ltrs. ( Approx. ) 4, Temp Range To Bemaintained +2ºc To +8ºc For 6-8 Housatambienttemprature Of 40ºc To 45ºc . 5, Insulation Material Cfc Free Polyurethane Foam ( Puf ) With Appropriate Thickness Or Equivalent Material. 6, Internal Lining Material Hips ( High Impact Polystrence ) Or Equivalentwith Smooth Finish . 7, External Surface Material Hdpe ( High Density Polyethylence ) Or Equivalent. 8, Coolgel Of Sixe – 21X8cm ( 12Nos. ) To Be Supplied With Each Unit.9, Soft-Padded Handle & Adjustable Shoulder Strap, With Two Additional Straps. 10, Warranty: 3 Years. 11, Certification Iso 9001. , Computer Table W X H X D: 77 Cm X 123 Cm X 61 Cm ( 2 Ft 6 In X 4 Ft X 2 Ft ) With Cpu Compartment Built-In Keyboard Tray , Delievery Kitcontaning :- I ) Cocker Forcep 8 A ) Straight =2, B ) Curved =2, Ii ) Apizotmy Sciessor =1, Iii ) Artery Forcep 6 =2, Iv ) Dressing Tooth Head = 1, V ) Myo Forcep 7= 1, Vi ) Spung Holding10=1, Vii ) Needle Holder 6=1, Viii ) Bowel =1, Ix ) Instrument Tray Ss With Cover 8X 10 =1 , Digital Thermometer For Freze:- 1 Infrared ( Non –Touch ) .2, Temperaturerange 30ºcto 150ºc.3, Display Ledwith Backlit. 4, Response Time:1 Second .5, Accuracy : +2% Of Reading . 6, Low Battery Indicator. 7, Display Hold Time: 15 Seconds. 8, Power Sourc:Battery. 9, Certification At Least National Physical Laboratory Certified.10, Calibration: Calibration Certificate In Original To Be Provided At The Time Of Supply. 11, Warranty 3 Year. , Dressing Forceps S.S. Superior Quality ( 304 Grade ) , Dust Bin 10 Ltr Plastic ( First ) Body ( Blue Black Yellow ) Foot Operated , Dust Bin 20 Ltr Plastic ( First ) Body ( Blue Black Yellow ) Foot Operated , Dustbin 10 Liter ( A Grade Plastic ) , Dustbin 40 Liter ( A Grade Plastic ) Different Colors , Ent Set : Consisting Of Otoscope, With 3 Speculae, Nasal Speculum, Bent Arm Illuminator, Tongue Depressor, Laryngeal Mirror, Andbattery. , Face Shield ( Studds Type ) , Fire Extinguisher ( Abc ) 5 Kg Isimark , Fire Extinguisher ( Co2 ) 4.5 Kg Isi Mark , Flowmeter With Humidifier Bottle Isi Marked , Focous Lamp : Led Light. Illumination ( Lx ) Should Be Led. Minimum 40, 000 Lux. Height Adjustment ( Mm ) : <=440. Radial And Axial Movement Of The Lamp. , Foetal Doppler Digital ( Bpl ) : Water Proof Probes Of 2Mhz, 3Mhz And 5Mhz Frequency, Ultra Sound Intensity <10Mw / Cm2, Auto Shut Off Facility To Save Battery Power, Built-In-Speaker, Volume Control Facility And Audio Output For Ear Phone, Heart Rate Range Should Be From 50 To 120 Bpm With Accuracy Of + / -2%, Should Be Water Proof Body, Should Have Facility For Fhr Data Transfer To Pc. 2.2 Settings Setting Of Ultrasound Intensity. 2.3 Users Interface Lcd Display 2.4 Software And / Or Standard Of Communication ( Where Ever Required ) Inbuilt , Fogger Machine ( Genex ) , Fogging Solution Enviroguard Plus ( Genex ) , Foot Operated Sanitizer Steel Stand ( Ss ) ( 304 Grade ) , Forceps 6 S.S. Superior Quality ( 304 Grade ) , Fumigator : 15 Microns Mesh Size, Low Noise Levels, Energy Efficient ( Max Life ) , Hospital Mattress Specification: Made Of Polyurethane Foam With Rexine Cover. 75X35X4 , Hub Cutter Electric { Astha } , Hub Cutter Non Electrical Stainless Steel , Hub Cutter With Sharp Container Of 1 Lt Capacity Cutting Life Of Blade Is 5000 Minimum Ats. Blade Is Made Of Stainless Steel ( 156911 Of 1992 ) Thickness Of Blade Should Be 0.5 Mm { Astha } , Instrument Traywith Lid ( S.S ) Size - 10X12 ( 304 Grade ) , Instrument Tray With Lid ( S.S ) Size - 12X18 ( 304 Grade ) , Instrument Tray With Lid ( S.S ) Size - 8X10 ( 304 Grade ) , Instrument Tray With Lid ( S.S ) Size - 12X15 ( 304 Grade ) , Instrument Trolley : Strong Stainless Steel ( Ss 304 ) Frame Work. Two Stainless Steel Shelves. Provision Of Ss Railing On Both Top And Bottom Shelves. Mounted On 4X100 Castors, 2 With Breaks. Size : 60L X50w X 82H Cm. Supplied In Knock Down Condition. ( 304 Grade ) { Bharat } , Iud Kit :- I ) Sponge Holdingforcep10=1, Ii ) Sims Speculum Medium =1, Iii ) Utrine Sound =1, Iv ) Cusko Speculum Medium =1, V ) Velselum Forceps10 =1, Vi ) Chittel Forcep =1, Vii ) Instrument Tray 10X8= 1. Ss With Cover, Viii ) Kidneytray =1, Ix ) Artery Forcep Straight 8=1, X ) Scissor Thread Cutting8=1, Xi ) Plastic Box Big Size =1, Xii ) Bowel =1 ( 304 Grade ) , Kidney Trays 25 Mm. ( 304 Grade ) , Labour / Delivery Table { Bharat / Aone } 304 Grade Ss , Langote For Nsv , Laryngoscope - Adult : Fiber Optic Laryngoscope-Preferably Should Be Reusable Using The Latest Led Technology. The Main Body Of The Handle Should Incorporate An Excellent Grip & Should Feel Even Wearing A Glove. There Should Bea Freely Moving Light Intensifier Of Light From The Light Source Through To The Tip Of The Fiber Optic Blade To Prevent Anypossibility Of Cross Contamination. The Unit Should Allow The Blade To Be Inserted Easily & Should Provide A Prositive Locking Mechanism When Moved In To The Closed Position.Battery Charges 120V, 60Hz Mono-Phase Electrical Source With Line Connecting Plug Nema 5-15 Type. Protections Against Over-Voltage And Over-Current Line Conditions. { Imported } , Laryngoscope - Pead. : Fiber Optic Laryngoscope-Preferably Should Be Reusable Using The Latest Led Technology. The Main Body Of The Handle Should Incorporate An Excellent Grip & Should Feel Even Wearing A Glove. There Should Bea Freely Moving Light Intensifier Of Light From The Light Source Through To The Tip Of The Fiber Optic Blade To Prevent Anypossibility Of Cross Contamination. The Unit Should Allow The Blade To Be Inserted Easily & Should Provide A Prositive Locking Mechanism When Moved In To The Closed Position.Battery Charges 120V, 60Hz Mono-Phase Electrical Source With Line Connecting Plug Nema 5-15 Type. Protections Against Over-Voltage And Over-Current Line Conditions. { Imported } , Linen Trolly Ss Frame 304 Grade , Microscope ( Binocular ) With Led Labomed , Microscope ( Binocular ) With Led Olympus , Myo Scissors 8 Long S.S. Superior Quality 304 Grade , Myo Scissors 8 Straight S.S. Superior Quality 304 Grade , Nebulizers : A 120V, 60Hz Mono- Phase Electrical Source With Line Connection Plug Nema 5-15 Type. Protections Against Over-Voltage And Over-Current Line Conditions. { Bpl / Omron / Beurer } , Needle Holder 6 S.S. Superior Quality 304 Grade , Needle Holder 8 S.S. Superior Quality 304 Grade , Non Toothed D Forceps S.S. Superior Quality 304 Grade , Non Toothed Dissecting Forceps ( 6” Long ) 304 Grade , Nsv Forcep ( Set Of 2 ) 304 Grade , Nsv Set ( Superior Quality Instrument ) 304 Grade , Oxygen Flow Meter With Humidifier Bottle :Chromium Plated Brass Body, Metering Tube And Cover Made Ofpolycarbonate Body, Flow Adjustment By Needle Valve Equipped With Inlet Filter-100 Um, Flow Rate 0-15 Liters Per Minute, Flush Flow 60 Litres Per Minute, Flow Read By The Centre Of The Ball, Inlet Pressure 60Psi; Humidifier Bottle: Lid Made Of Abs Plastic, Jar Made Of Unbreakable Poly Carbonate, Valve Pressure Brass Chromium Plated, It Should Be Steam Autoclaved / Gas Sterilized. , Oxygen Hood , Oxygen Hood For Neonates , Panasonic Cell Aaa , Portable Autoclave : High Grade Strong Stainless Steel, Triple Walled Construction. Positive Radial Self-Locking Safety Doors. Hydrostatically Tested To Withstand 2.5 Times The Working Pressure. Sealed With Neoprene / Silicon Long-Lasting And Durable Gasket. Digital Display For Jacket And Chamber Pressure And Temperature. Outer Jacket Insulated To Prevent Heat Loss; With A High Grade Insulation Material. Mounted On 304 Stainless Steel Frame With Ground Leveling Flanges. Temperature And Pressure Cut-Off Device. Auto Cut-Off At Low Water Level. Rust-Proof 304 Grade Stainless Steel. Cylindrical Construction. Equipment Should Have Separate Steam Release Valve And Drainage System. Minimum Of Two Safety Valves With Auto-Release At 16 And 20.Single Drum 12X20 Cooker Type , Portable Autoclave : High Grade Strong Stainless Steel, Triple Walled Construction. Positive Radial Self-Locking Safety Doors. Hydrostatically Tested To Withstand 2.5 Times The Working Pressure. Sealed With Neoprene / Silicon Long-Lasting And Durable Gasket. Digital Display For Jacket And Chamber Pressure And Temperature. Outer Jacket Insulated To Prevent Heat Loss; With A High Grade Insulation Material. Mounted On 304 Stainless Steel Frame With Ground Leveling Flanges. Temperature And Pressure Cut-Off Device. Auto Cut-Off At Low Water Level. Rust-Proof 304 Grade Stainless Steel. Cylindrical Construction. Equipment Should Have Separate Steam Release Valve And Drainage System. Minimum Of Two Safety Valves With Auto-Release At 16 And 20.Size 16 X 24 Double Drum , Ppiucd Forcep 12.5 304 Grade , Eye Vision Testing Drum ( Led ) , X-Ray View Box With 2 Led , Regular Stethoscope ( Microtone ) : Stethoscope Of Standard Size, Chromium Plated Metal Binaural, V Rubber Tube In One Piece. Rotating Piper Fitting For Both Flip Functions. , Scissor 6 Curved S.S. Superior Quality 304 Grade , Scissor 6 Sharp Straight S.S. Superior Quality 304 Grade , Scissor 8 Sharp Straight S.S. Superior Quality 304 Grade , Scissor 8 Straight S.S. Superior Quality 304 Grade , Sims Speculum ( Narrow ) ( Ss / 304 Min. ) , Vaginal Speculum Ss 304 Grade , Slide Box Wooden With 50 Capacity , Sponge Holding Forceps S.S. Superior Quality Msc 304 / 316 , Sterilization Rolls For Packing Instrument 10Cm X 200 Mtrs. ( Livral ) , Sterilization Rolls For Packing Instrument 15Cm X 200Mtrs ( Livral ) , Stethoscope Daimond , Stethoscope ( Microtone ) , Stethoscope Neonatal ( Microtone ) , Stethoscope Pediatric ( Microtone ) , Suction Machine Foot Operated : Technical Characteristics ( Specific To This Type Of Device ) Giving Vacuum More Than 550Mm Hg, With 200Ml / Stroke; Oil Free Diaphragm Pump. Settings Manual Users Interface Manual Software And / Or Standard Of Communication ( Where Ever Required ) ( Easycare / Pi ) , Suction Machine Electric Operated : Technical Characteristics ( Specific To This Type Of Device ) Giving Vacuum More Than 550Mm Hg, With 200Ml / Stroke; Oil Free Diaphragm Pump. Settings Manual Users Interface Manual Software And / Or Standard Of Communication ( Where Ever Required ) { Easycare / Anand } , Thermometer Digital ( Microtek ) : Operational Characteristicssuitable For Oral, Axillary And Rectal Use. Clinical Measuring Range At Least Of 32-42 0C. Accuracy Not Higher Than + / - 0, 50C. Digital Display Window To Show The Temperature In 0C. Measuring Time No Greater Than 10 Sec. Alkaline Commercial Button Battery Operated ( Battery Included ) Battery Life At Least Of 1000 Takes. Auto Shut-Off. Water And Disinfectant Resistant. , Tubectomyset ( Superior Quality Instrument ) 304 Grade , Vtm Rack- Made Of Plastic Material With 36 Holes Of 20Mm Sizes, Three Tiers With Numbering Each Hole. Holes Should Be In All Three Tiers 20Mm Size In Ist & 2Nd Tiers And 6-8Mm Hole Size In Ground Tier. , Vulsellum Forceps S.S. Superior Quality 304 Grade , Weighing Machine Adultmanual Krups / Suvrna , Weighing Machine Adult Digital { Bpl / Omron } , Focus Light { Max / Aone } , Examination Light { Max / Aone } , Ot Table { Bharat / Aone } , Examination Table { Bharat / Aone } , Gynae Table Telescopy { Bharat / Aone } , Dressing Trolley: S.S. 304 Grade ( Bharat / Aone )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
45.
Housing Urban and Rular Development #10598781 Price Bid
Special Repair Of Electrical Installation & Fans & Replacement Of Main Panel, Dbs & Cables & Providing Acs, Dg Set At Office Of The Sub-Divisional Magistrate ( Kalkaji ) , 37-Institutional Area Tughlakabad, New Delhi-110062. ( Sh:-Supply Installation Testing And Commissioning Of 125 Kva Dg Set ) . , Sub Head - Dg Set Providing , Installing , Testing & Commissioning Of Silent Type Diesel Generating Set Having Prime Power Rating Of 125 Kva , 415 Volts At 1500 Rpm , 0 . 8 Lagging Power Factor At 415 V Suitable For 50 Hz , 3 Phase System & Consisting Of The Following: ( A ) Diesel Engine: Diesel Engine 4 Stroke Water Cooled , Electric Start , Of Suitable Bhp At 1500 Rpm Under Ntp Conditions Of Bs:5514 Capable Of Taking 10% Over Loading For One Hour After 12 Hours Of Continuous Operation . The Engine Will Be Fitted Complete With All The Required Accessories . ( B ) Engine Mounted Instrument Panel Fitted With Accessories & Indicators To Indicate Necessary Parameters And Having Digital Display As Per Standard Design Of The Manufacturer . I ) Start-Stop Switch Ii ) Water Temperature Indication Iii ) Lubrication Oil Pressure Indication Iv ) Battery Charging Indication V ) Rpm Indication Vi ) Over Speed Trip Indication Vii ) Low Lub . Oil Pressure Trip Indication Viii ) Engine Hours Indication Ix ) Kwh Meter ( To View The Record Of Total Unit Generated Upto Date ) . , ( C ) Alternator: Synchronous Alternator Rated At 125 Kva , 415 Volts At 1500 Rpm , 3 Phase , 50 Hz , Ac Supply With 0 . 8 Lagging Power Factor At 40 Degree C , 50% Rh At 1000 Mtr . Msl & At Ntp Conditions . The Alternator Shall Be Having Spdp Ip 23 Enclosure , Brushless , Continuous Duty , Self-Excited And Self-Regulated Through Avr Conforming To Bs:2613 . Suitable For Tropical Conditions And With Class-H Insulation . ( D ) Base Frame & Foundation: Both The Engine & Alternator Shall Be Mounted On Suitable Base Frame Made Of Ms Channel With Necessary Reinforcement Which Shall Be Installed On Suitable Cement Concrete Foundation & Vibration Isolation Arrangement As Per Recommendations Of Manufacturer . ( E ) Fuel Tank: Daily Service Fuel Tank Of 330 Liters Capacity Fabricated Out Of 3 Mm Thick M . S . Sheet Complete With All Standard Accessories & Fuel Piping Between Fuel Tank & Diesel Engine With Ms Class C Pipes Of Suitable Dia . Complete With Valves , Level Indications & Accessories As Required As Per Specifications . ( F ) Exhaust System: Dry Exhaust Mainfold With Hospital Silencer As Per Cpcb Norms . , ( G ) Starting-System: 12V / 24V Dc Starting System Comprising Of Starter Motors: Voltage Regulator And Arrangement For Initial Excitation Complete With Maintenance Free Batteries As Recommended By Manufacturer Of Dg Set & As Required As Per Specifications . ( H ) Acoustic & Weather Proof Enclosure With Arrangement For Fresh Air Intake For Cooling Of The Engine & Alternator , Extraction , Discharging Hot Air In To The Atmosphere As Per Specifications . , Fabricating , Installation , Testing & Commissioning Of Automatic Mains Failure Panel Fabricated In 2 Mm Thick Crca Sheet Steel With Suitable Size Ms Base Channel , Floor Mounted For Existing Dg Set Of 125 Kva , Including Manual Bypass For Both Main And Dg Set Supply Complete With Aluminium Bus Bars , Suitable For 125 Kva Silent Type Dg Set Complete With Relays , Timers , Set Of Cts For Metering & Protection & Energy Analyser To Indicate Current , Phase & Line Voltages , Frequency & Provision For Overload , Short Circuit , Restriction Earth Fault , Under Frequency , Connection With Existing Control Cabling Of Dg Set To Amf Panel , All Complete & Inter Locking Arrangement Including The Following . A ) 250 Amp 50 Ka 4 Pole Mccb - 2 Nos . B ) 250 Amp On Load 4 Pole Change Over Switch-2 Nos . C ) 250 Amp 4 Pole Power Contactor- 2 Nos . D ) Auto / Manual / Test / Off Selector Switch E ) 3 Nos . Of Current Transformer 250 / 5 Amps For Metering . F ) Energy Analyzer Unit To Indicate Current Voltage Frequency G ) Indicating Lamps For Load On Mains And Load On Dg Set . , H ) Sp Mcb For Instruments . I ) Control Unit With Three Impulse Automatic Engine Start / Stop And Failure To Start Lockout . J ) On / Off / Control Circuit With Indicator . K ) Audio / Video Annunciation For High Water Temperature Low Lubricating Oil Pressure Engine Over Speed Engine Fails To Start Amf Panel As Described Above , Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump , Dg Set Etc . Including Form Work Etc . As Required . , Earthing With G . I . Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories , And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2 . 7 Meter Long Etc . With Charcoal / Coke And Salt As Required . , Providing & Fixing 25 Mm X 5 Mm G . I . Strip On Surface Or In Recess For Connections Etc . As Required . , Providing & Fixing 25 Mm X 5 Mm G . I . Strip In 40 Mm Dia G . I . Pipe From Earth Electrode Including Connection With G . I . Nut , Bolt , Spring , Washer Excavation And Re-Filling Etc . As Required . , Fabrication Supplying Installation Testing & Commissioning Of Cubical Feeder Pillar Panel Board , Dust , Damp And Vermin Proof , Compartmentalized Made Out Of 2 . 0 Mm Thick ( Ns ) Crca Sheet Duly Powder Coated , 300 Mm Deep Complete With 4 Strips Alu . Bus Bar Of 300Amps . Capacity Complete With Connection , Interconnections , Internal Wiring With Copper Conductor Cable Of Suitable Sizes , Earthing Etc . As Reqd . , Providing & Fixing Following Rating & Breaking Capacity And Pole Mccb With Thermomagnetic Release & Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . , 100 A , 16 Ka , Tpmccb , 125 A , 16 Ka , Tpmccb , 250 A , 36 Ka , Fpmccb , Credit Item , Less Credit For Unserviceable 62 . 5 Kva Dg Set .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
46.
Drinking Water Supply and Sanitation #10578819 Price Bid
Supply, Installation, And Commissioning Of Electro-Mechanical Components At Tube Well No. Iii And Iv Of Augmentation Of Bhaluka Fatepur Water Supply Scheme ( Tsm / 009046 ) - 1 Supply And Delivery At Site Of Following Pumping Machinery And Electrical Accrssories: 2 Submersible Pump Directly Coupled With Water Proof Suitable Size Motor Having Following Specification And As Per Nit Specification:Pumpshaft- Stainless Steelimpeller- S.S / Gmoutlet Size-80 Mmmotorsubmersible Type 3 Phase, 50 Hz, 415V ± 10% , 2900 Rpmmotor Mustbe Suitable For Operation With Star-Delta Starter Test Certificate Along With Characteristic Curve Shoule Besubmitted At The Time Of Delivery. ) 3 For T / W No.- Iiidischarge Of Clear Water = ( Q ) = 30 M3 / Hr.Total Head ( H ) = 57 M. 4 For T / W No.- Ivdischarge Of Clear Water = ( Q ) = 30 M3 / Hr.Total Head ( H ) = 57 M. 5 1.1 Kv Grade 3 Core Water Proofflat Submersible Cable For Above Motor.6 Sq. M.M. 6 For T / W No. Iii & Iv4 Sq. M.M. 7 1.1 Kv Grade 25 Sqmm 3.5 Core Xlpe Insulated Al. Ar. Cable Cable Conforming To Is-7098 ( Part-1 ) 1988 With Upto Date Amendment. 8 Supply, Delivery And Storage At Site Of Wall Mounted 2 Mm. Thick Epoxy Painted Sheet Steel Enclosed Front Open Fully Panel For Fully Automatic Cum Manual Control Centre For Operation Of The Pump Motor In Star-Delta, Actuator With Dol Starter, Chlorinator With Dol Starter And Timer Operated Outdoor And Indoor Lighting And Also Spares Feeder As Per Approved Drawingand Nit Specification. 9 Range Of Pmcc Panel:7.5 Hp To 12.5 Hp 10 Supply And Delivery Of The Following Valves, Pipes, Gauges Etc. At Site. 11 80 Mm Dia M.S. Seamless Column Pipe ( Black ) 6.8 Mm To 7.1 Mm Thick With 150 Mm Long Heavy Type Socket At One End. 12 3.00 Mtr. Long Excluding Socket Having 8 T.P.I. Thread. 13 1.5 Mtr. Long Excluding Socket One End Having A Thread Of 11 T.P.I. & The Other End Having A Thread Of 8 T.P.I. 14 Heavy Type Suitable Dia Ms Suspension Clump, Along With Nuts Bolts And Washer. 15 Cast Iron Wafer Type Three Phase Multi-Turn Actuator Operated Butterfly Valve Of Dia 80Mm ( P.N-1.0 ) As Per ( Is-13095 Ip-68 ) Test Certificates From Both The Manufacturer Are To Be Submitted At The Time Of Delivery 16 80Mm Dia Cidf Sluice Valve-1 No., Non Return Valve-1 No., Cidf 90° Bend-1No., Ci Flanged Tee-1No. Blank Flange-1No., Ci / Ms Flanged Short Piece 0.50 Mtr.-2 Nos, Ci / Ms Flanged Pipe 1 Mtr.-2 Nos. 1 No. Suitable Ms Enlarger With Ms Nipple For 80 Mm Dia Outlet If Required Etc As Per Is Specification And Certification For Construction Of Delivery Pipe Line And Wash Out Line. 17 Heavy Type 250 Mm Dia Split Type Tube Well Cover With 12 Mm Thick Clamping Arrangement Including Holes Of Column Pipe, Air Pipe And Cable Entry With 2 Sets Heavy Type Suspension Clump, Nuts, Bolts And Washer As Per Departmental Design. 18 Depth Gauge 100Mm Dia With Steel Air Pipe Of Required Length With All Accessories For The Above Work Including Supply Of Good Quality Hand Pump. ( This Cost Includes 15 Mm. Dia G.I. Pipes And Specials ) 19 Pressure Gauge ( H.Guru / Febig ) 150Mm Dia ( 0-7Kg / Sq.Cm ) Brass Cock And Fitting Complete. ( This Cost Includes 15 Mm. Dia G.I. Pipes And Specials ) 20 50 Mm. Dia. Non Metalic Pipes ( Is:14930 ) And Specials For Protection Of Submersible Cable ( As Per Site Requirement ) 21 Anti Snapping Safety Device For Pump Set By Supplying Suitable Size Ms Clamps Two Sets And Nylon Rope Of Required Length Including Supplying Of Nuts, Bolts And All Other Materials. 22 100 Amps 415Vporcelain Based Rewireable Type Male-Female Kit-Kat Fuse Unit. 23 100 Amp 415 V Rewireable Type Tpn Main Switch. 24 Laying Of 25 Sq. Mm. 3.5 Core Al. Ar. Cable In Wall / Floor By Supplying Of All Necessary Materials As Per Ie Rules And As Per Direction 25 Installation Of The Materials ( To Be Supplied Under Above Sl No 1 To 3.01 & 5 To 6.13 ) Such As Pump Motor Set With Column Pipes, Valves, Panel, Fiting Fixing Pressure Gauge, Depth Gauge, Non-Return Valve & Drawing Delivery Out-Let & Washout Line With The Supplied Specials / Accessories By Providing Antisnapping Cage Of Suitable Size Including Supply Of Cable Gland, Sockets, Wooden Board, Control Cable Etc Including Brick, Sand, Cement Rod Etc As Required To Complete The Job As Per Direction And Up To The Entire Satisfaction Of The Eic. 26 Making Brick Pillar 0.25 Mtr X 0.25 Mtr. For Supporting Of Valves And Pipes With 12 Mm Thick Plaster And Net Cement Finish Complete. 27 Supply, Delivery Of M.S Kiosk Box Of 661Mm X 559 Mm ( Lxw ) Size Having Thickness Of 1.5 Mm With Angle Support At Four Legs Having Hight Of 661 Mm With Provision Of Locking Arrangement, Supply Of Lock, Cable Entry Point Incl Painting By One Coat Of Black Paint Over One Coat Of Primer All Complete. 28 Making Suitable Size Pump Foundation Including Erection Of Kiosk Box With Supplying Of Necessary Cement, Sand And Stone Chips Including Plastering And Net Cement Finish Complete. 29 Making Double Earthing Arrangement In Compliance With Ie Rules By G.I. Pipe Electrode Of 50 Mm. Dia 3 Mtr. Long 2 Nos For Panel And Pumping Machinery 25 Mm. X 6 Mm. G.I. Earth Strips From Earth Pit To Panel And All Other Accessories Required To Complete The Work. 30 Making Internal Electrification Of Pump House Consisting Of Two Bracket Point, One Tube Light Point, Two Bulk Head Point, One Fan Point And 1 No. 74 Watt Led Fixture With Arm Bracket At Outside And One Three Pin Plug Point Including Supply Of All Necessary Materials To Complete The Work As Per Ie Rules And As Per Direction ( All The Fittings And Lamp Should Be Led Type As Per Choice Of Eic ) 31 Supply And Delivery Ofpvc Moulded Chair. 32 Supply And Delivery Of Pvc Moulded Table. 33 Supply, Delivery & Installation Of The Following Fan As Directed By Eic.Ceiling Fan 1200Mm Sweep Including Fan Clamp As And When Required. 34 Supply And Delivery At Site 3 Phase Oil Cooledtype Servo Motor Operated Copper Wound Line Voltage Corrector Conforming To Is-9815 ( Pt.-1 ) -1994 Suitable For Un-Balanced Input Voltage Phase To Phase 200V.-500V Including First Filling Oil As Per Is-335 Where Applicable As Per Approved Drawingand Nit Specification. 35 For T / W No. - Iii & Iv 20 Kva 36 Supply And Delivery Of Following Materials At Site 37 100 Amps, 415 V, 4 Pole On Load Change Over Switch. 38 100 Amps, 415 V Tpn Rewireable Type Mainswitch. 39 100 Amps 4 Way Copper Bus-Bar Chamber. 40 1.1 Kv Grade 415 V, 25 Sqmm, 3.5 Core Pvc Insulated Aluminiumarmoured Cable. 41 Making Brick Built Foundation With Supplying Of All Required Materials Suitable For The Above Voltage Stabilizer By ( 4:1 ) Cement Mortar Including Holding Down Foundation Bolts And 12 Mm Thick Plaster With Neat Cement Finish, Sloping All Complete As Per Direction Of Eic. 42 Fitting , Fixing Of Change Over Switch, Busbar Chamber And Main Switch As Mentioned In Item No. 18.01, 18.02 And 18.03 On The Iron Angle Frame Of Suitable Size Fixed At Suitable Position On Wall By Supplying All Necessary Fixing Materials All Complete As Per Direction Of Eic. 43 Installation Of The Above Voltage Stabilizer As In Item No.17.00 On The Foundation Including Making All Connection Complete As Per Direction. 44 Drawing And Connection Of Cable As In Item No. 18.04 On Wall / Surface From Change Over To Panel Via Voltage Stabilizer, Bus Bar And Main Switch Incl. S & Fitting-Fixing Of Required Nos. Of Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting. 45 Making Joints Of The Cable By Supplying Compresion Type Gland Thimple, Socket Etc. As Per Requirement And As Per Direction Of Eic. 46 Double Earthing The Whole Installations Complying With Ir Rules Including Supplying Of All Necessary Earthing Materilas For Voltage Corrector Device To Complete The Job As Per Direction Of Eic. 47 Supply & Delivery Of Automatically Controlleddiaphargm Type Chlorinator For Accurate Dosing Of Chlorine Solution Into The Waterby Connecting Metering Pump ( Diaphargm Type ) Having Following Specification:- Pump Type ::Diaphargmliquid ::Chlorine Solutioncapacity ( Lph ) :: 0-100Pressure Kg / Cm2 ( Testing ) :: 10Pressure Kg / Cm2 ( Suction ) :: Floodedpressure Kg / Cm2 ( Hydro ) :: 15Connection Suction :: ½” Hose Holderconnection Discharge :: ½: Hose Holdermoc Liquid End :: Ppdiaphragm :: Ptfenrv :: Ppdrive Capacity :: 0.5Hp, 3 Phase, 50Hz, 415V, 1440 Rpmmotorcoupling Capacity :: Flexible Spiderstrainer :: Y Type, Pp, ½” Bsp ( F ) Pressure Relief Valve :: Inbuilt.Solution Tank :: 100 Ltr Capacity ( Including Making Provision For Inlet Line To The Actual Storage Tank Of Dosing Solution Of All Materials. Test & Warrantycertificatesare To Be Submitted At The Time Of Delivery 48 Installation Of Above Supplied Chlorinator With All Accessories, Pvc Tankand Drawing Of Power Line As Per Ie Rules By Supplying Pvccopper Wire & Continuous Earthing. This Includes The Cost Of All Necessary Cc Foundation ( At Least 200Mm Height ) With Concrete Mixture ( Sand, Cement, Stone ) And Neat Cement Finish By Supplying Of All Required Materials And Testing The Entire Set As Perentire Satisfaction Of The Eic. ( Power Will Be Fed From Plc Panel Of Pumping Machinery ) 49 Commissioning Of The Installation With Full Satisfaction Of Eic. 50 Trial Operation. Maintenance, Guarding Of The Installation Roud The Clock For A Period Of 30 Thirty ) Days From The Date Of Receipt Of Service Connection By Engaging Personnel Having Sufficient Experience In Electrical Installation. 51 Make As Per Departmental Approved Vendor List Circulated Vide Memo No.Phe / Iv / 2277 / W-181 / 19 Dated- 25 / 09 / 2019 52 N.B. Progressive Bills Shall Only Be Done After Third Party Inspection Agency Engaged By Phed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
47.
Power #10574490 Price Bid
Construction Of33 / .04 Kv S / S ( 2X1000 Kva ) Tilapur ( Dattaha ) Pump Cannaldistt- Ballia And 14.00 Km Long33 Kv Line Tilapur ( Dattaha ) Pump Cannal Line From 132 / 33 Kv S / S Husainabad ( Bansdeeh ) In Distt- Balliaunder Deposit Scheme 2022-23. 1 Supply Of Materials ( 33 / .04 Kv Substation ) 2 33Kv Vcbwith Structure 3 33Kvcontrol Pannel For Single T / F Control Panel 4 33Kvct 200 / 100 / 1A With Structure 5 33Kv Pt O / D 33 / 110V 6 33Kv L.A. ( 01 Set=3 Nos ) 7 33 Kv Post Insulator. 8 33 Kv Disc Insulator 70Kn 9 33 Kv Disc Fitting B&S 10 33 Kv Polymer Pin Insulator 11 33 / 0.4 Kv 1000 Kva T / F 12 Acsr Dog Conductor 13 Lt Pvc Cable I / C 3.5X400mm2 14 33 Kv Busbar Gantry With Two Nos Structure 15 33 Kv La Structure 16 33 Kv Isolator Structure 17 33 Kv Post Structure 18 33 Kv Fuse Set Structure 19 33 Kv Pt Structure ( 01 Setfor 3 Nos Pt ) 20 90 Lbs Rail 2.5 Mtr Long For Two Nos Plinth 21 33 Kv Fuse Set Complete 22 33 Kv Bus Isolator 23 33 Kv Line Isolator 24 Ms Angle 65X65x6mm 25 24 Volt Battery With Charger With Cabinet 26 Control Cable 2X2.5Mm2 27 Control Cable 4X2.5Mm2 28 Pg Clamp Of Dog Conductor 29 Al Lug 300 Sqmm For Lt Cable Long Size 30 Lt Incomming Pannel 31 Lt Outgoing Pannel 32 Lt Distribution Pannel 33 Rubber Mat 34 Fire Fighting Stand With Bucket 35 Hand Gloves 36 Furnitures 37 S / S Name Board And Arrow Board 38 33 Kv Vcb Connecter 39 33 Kv Ct Connecter 40 33 Kv La Connecter 41 33 Kv Top Channel For Cable Stand 42 Erectionwork 43 Erection & Grouting Of33kv Busbar Gantry With Two Nos Structure As Per Resspo Norms 44 Erection & Grouting Of33kv La Structure As Per Resspo Norms 45 Erection & Grouting Of33kv Isolator Structure As Per Resspo Norms 46 Erection & Grouting Of33kv Post Structure As Per Resspo Norms 47 Erection & Grouting Of33kv Fuse Set Structure As Per Resspo Norms 48 Erection & Grouting Of33kv Ct Structure As Per Resspo Norms 49 Erection & Grouting Of33 Kv Bus Isolator & Line Isolator Structure As Per Resspo Norms 50 Erection & Grouting Of33 Kv Pt Structure As Per Resspo Norms ( 1 Set=3 Nos Pt ) 51 90 Lbs Rail 2.5 Mtr Long For Two Nos Plinth As Per Resspo Norms 52 Erection & Grouting Of33kv Vcb With Structureas Per Resspo Norms 53 Erection & Grouting Of 33Kv Control Pannel For Single T / F As Per Resspo Norms 54 Erection & Grouting Of 33 Kv C.T. 200 / 100 / 1 Ampas Per Resspo Norms 55 Erection & Mounting Of33 Kv Pt O / D 33 / 110V As Per Resspo Norms 56 Erection & Mounting Of33 Kv L.A. As Per Resspo Norms 57 Erection & Mounting Of33kv Post Insulator As Per Resspo Norms 58 Erection & Mounting Of33kv Fuse Set Complete As Per Resspo Norms Providing Suitable Size Of 2 Set ( 12 No ) Copper Z Clamp With Nut Bolt ( 1 Set =6 No Copper Z Clamp ) 59 Erection & Mounting Of33kv Bus Isolator As Per Resspo Norms 60 Erection & Mounting Of33 Kv Line Isolator As Per Resspo Norms 61 33Kv Disc Insulator 70Kn As Per Resspo Norms 62 33Kv Disc Fitting B&S As Per Resspo Norms 63 33Kv Polymer Pin Insulatoras Per Resspo Norms 64 Installation Of 33 / 0.4Kv 1000 Kva T / F As Per Resspo Norms And Connections Of All Jumpers With Providing Suitable Size Of 2 Set ( 14 No ) Copper Z Clamp With Nut Bolt ( 1 Set =7 No Copper Z Clamp ) 65 Ms Angle 65X65x6mm For Neutral Stand As Per Resspo Norms 66 Acsr Dog Conductor 67 Earthing Of Switchyard Of O / D Structures And Equipments With Earthmat As Per Resspo Norms For 2 No Power T / F. 68 Earthing Of I / D Equipments As Per Resspo Norms 69 Plinth And Foundation Powert / F As Per Resspo Norms 70 Plinth And Foundation Of Vcb As Per Resspo Norms 71 Laying Of Lt Pvc Cable I / C 3.5X400mm2 From 1000 Kva T / F To Metering / Control Room & Load Point With Complete In All Respect As Per Resspo Norms After Providing Alluminium Lug Suitable Size. 72 Separate 2 No Body Earthing & 1 No Delta Earthing Of Neutral Of T / Fs With 40Mm Dia Gi Pipe 30 Feet Long As Per Resspo Norms Upto Water Label. 73 24 Volt Battery With Charger With Cabinet 74 Armoured Control Cable 2X2.5Mm2 As Per Resspo Norms 75 Armouredcontrol Cable 4X2.5Mm2 As Per Resspo Norms 76 Pg Clamp Of Dog Conductor 77 Al Lug 300 Sqmm Long Size For Lt Cable As Per Resspo Norms 78 Insttalation & Connction Of Lt Incomming Pannel As Per Norms With All Required Materials 79 Insttalation & Connction Of Lt Outgoing Pannel As Per Norms With All Required Materials 80 Insttalation & Connction Of Lt Distribution Pannel As Per Norms With All Required Materials 81 S / S Name Board And Arrow Board As Per Resspo Norms 82 Cost Of Pakka Trench For Laying Of Control Cables As Per Resspo Norms 83 Outdoor Switchyard Lighting ( With Supply, Erection & Painting Of7 No 9 Mtr St Poles, 250 Mtr 4 Core Alluminum Cable For Connection, 7 No 120 Watt Led Street Light With Clamp For St Poles Complete Work Upto Enerzigation After Providing All Materials. 84 Construction Of Approach Road Inside The Switchyard 1.5 Mtr Wide With 1St Class Bricks On Edge Soling & Tipping Complete Work Including Cost Of All Materials. 85 Painting Of All Structures & Equipments As Per Resspo Norms 86 Supply Of Materials ( 33 Kv Line ) 87 St Pole 11 Mtr 88 St Pole 13 Mtr 89 Acsr Dog Conducter 90 33 Kv V Type X-Arm 91 33 Kvdisc Fitting B& S 92 33 Kv Polymer Pin Insulater 93 33 Kv Xlpe Cable 3X300 Mm2 94 33 Kv Polymer Disc Insulater B& S 95 Gi Wire 6&10 Swg 96 33 Top Channel Clamp For St Pole 11 Mtr With Nut Bolt 97 33 Kv Garding Angle Clamp With Nut Bolt With Nut Bolt 98 33 Kv E-Clamp For Stp 11 Mtr With Nut Bolt 99 33 Kv Bracing Angle Clamp For Stp Top / Botttom Pole With Nut Bolt 100 Pg Clamp For Dog To Dog 101 33 Kv Cable Jointing Kit 3X300mm2 O / D 102 33 Kv Cable Jointing Kit 3X300mm2 S / T 103 Danger Board With Clamp With Nut & Bolt 104 Nut & Bolt Different Sizes 105 Gi Barbed Wire 106 Packing Piece For St Pole 107 33 Kv X-Arm Clamp For 11 Mtr St Polewith Nut Bolt 108 33 Kv F Bracket For St Pole 11 Mtr With Nut Bolt 109 33 Top Channel 110 Earthing Complete 111 33 Kv Stay Set Complete ( 20X1800 Mm ) 112 33 Kv Bracing Angle 113 33 Kv Garding Angle 114 Erectionwork 115 Erection Of Single Pole Structure On 11Mtr St. ( Sp-55 ) Pole Including All Works Of Evocation Of Pit, Pole Erection, Making Plinth For Poles 30 Cm Above , Grouting In The Ratio 1:4:8 ( Cement, Sand, 40Mm Brick Ballast ) , Back Filling Of Earth , Proper Ramming & Fitting Of All Accessories 116 Erection Of Single Pole Structure On 13 Mtr St. ( Sp-55 ) Pole Including All Works Of Evocation Of Pit, Pole Erection, Making Plinth For Poles 30 Cm Above , Grouting In The Ratio 1:4:8 ( Cement, Sand, 40Mm Brick Ballast ) , Back Filling Of Earth , Proper Ramming & Fitting Of All Accessories 117 Erection Of Double Pole Structure On 11 Mtr St Pole Including All Works Of Evocation Of Pit, Pole Erection, Making Plinth For Poles 30 Cm Above , Grouting In The Ratio 1:4:8 ( Cement, Sand, 40 Mm Brick Ballast ) , Back Filling Of Earth , Proper Ramming & Fitting Of All Accessories. 118 Erection Of Double Pole Structure On 13 Mtr St Pole Including All Works Of Evocation Of Pit, Pole Erection, Making Plinth For Poles 30 Cm Above , Grouting In The Ratio 1:4:8 ( Cement, Sand, 40 Mm Brick Ballast ) , Back Filling Of Earth , Proper Ramming & Fitting Of All Accessories. 119 Erection Of Four Pole Structure On 11 Mtr St Pole Including All Works Of Evocation Of Pit, Pole Erection, Making Plinth For Poles 30 Cm Above , Grouting In The Ratio 1:4:8 ( Cement, Sand, 40 Mm Brick Ballast ) , Back Filling Of Earth , Proper Ramming & Fitting Of All Accessories. 120 Laying, Spreading, Lifting And Final Sagging Of 3 Phases Of Acsr Dog Conductorin Accordance With Profile And Sag Chart Including Binding, Jumpering And Fixing Of P.G. Clamp As Per Requirement In 03 Nos. Conductor In Parallel. 121 Laying Of 33 Kv 3X300 Mm² ‘Xlpe’ Cable ( D / C ) By Digging Pit & Making Trench In Proper Size Below Ground Level By Fixing Bricks ( 4½? ) On Both Side Of Trench Wall And 9? Brick Work At The Centre Of The Trench Along The Cable.Fixing Brick Slab On Top After Filling Sand Around Both The Cable Including Cost Of Bricks. / Hdd Method As Per Size Required ( For 33 Kv Line And Metering Unit ) 122 Laying Of 33Kv ‘Xlpe’ Cable In Air After Providing 6” Dia. M.S Pipe 3.5 M Long Complete Work. 123 Special Gi Pipe Earthing Complete With Materials For 33 Kv ‘Xlpe’ C / J Kit. 124 Jointingcharges Of 33 Kv ‘Xlpe’ C / J Kit 3X300mm² Outdoor 125 Jointingcharges Of 33 Kv ‘Xlpe’ C / J Kit 3X300mm² Straight Through 126 Grouting Of Stay Rods ( 20 X 1800 ) Mm Including All Work Including Back Filling, Proper Ramming Etc. Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing. 127 Chopping Of Branches Of Trees Of Eucalyptus, Neem, Keekar And Other Kind Of Trees Along The Route Of The Line And Disposal Of The Same At Suitable Place. 128 Guarding Between Two Poles Like Single Poles, Double Poles, Four Poles, Etc. To Guard Lt, 11 Kv Line Telephone And River Crossing, Road Crossing Etc. With G.I. Wire No. 6 Swg And G.I. Wire No. 8 Swg, Cutting, Fabrication And Fixing Of Guarding Channel . 129 Earthing Of Poles 130 Painting Of Poles 131 Fixing Of Dangerboardwithclampfor33kv Line-1700000114 132 Fixing Of Barbedwire- 1400000219 133 Making Plinth For St Polespoles As Per Resspo- 1000001733 134 Shifting Of Existing Single Poles Of Ht / Lt Lines For Providing Passage For 33 Kv Line Tilapur Dataha By Safe Dismentling Of Existing Single Pole & Re-Erection Of Existing Poles With Complete Work Afterproviding Side -Arm With All Accessories . 135 Shifting Of Existing11 Kv Line / Lt Line On Acsr Weasal / Dog Conducter By Safe Dismentling Of Acsr Weasal / Dog Conducter & Re-Stringing Of Acsr Weasal / Dog Conducter On Shifted Poles With Complete Work After Providing All Required Materials For Shifting.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
50.
Water Resources and Irrigation #10558790 Price Bid
Supplying, Installation, Testing & Commissioning of Mix-flow type Electric Pump Sets & equipments with all accessories etc. including development of Substation for New Pump House at Jahangirpuri drain near Gopalpur Regulator RD-1135m.- 1 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 55 KW/75 HP , 6 Pole , 980 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 35x35 Size Pump set having 1400 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 2 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 75 KW/100 HP , 8 Pole , 740 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 40x45 Size Pump set having 2000 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 3 Supplying , installation, testing and commissioning of Sound Proof Steel enclosure Water Cooled Engine coupled with Alternator 320KVA/256 KW silent DG Generator set including Base frame, Radiator/Heat Exchanger/Fuel Tank/ Control Panel /AMF panel, fuel piping foundation, all interconnections, loop Earthing, Silencer completed all as per CPWD/CPCB norms with standard accessories etc. as required.(Make:- Crompton Greaves/ Kirloskar/ Cummins or as approved by Engineer-in-charge) 4 M.S. Pipes:-Manufacturing , Supplying, erection & commissioning of Mild Steel ERW, (Electric Resistance welded) Pipe fabricated/manufactured out of Fe410 Mild Steel Grade 330 as per IS: 3589 of reputed & approved make , including painting with epoxy paint inside and outside surface with two coats of anticorrosive paint of approved brand and manufacture : all conforming to relevant IS codes: complete in all respect and with upto date amendments in relevant IS codes:(Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge)1200mm nominal dia pipes of 12mm thick complete as required at site. 5 350mm nominal dia pipes of 8mm thick complete as required at site. 6 400mm nominal dia pipes of 8mm thick complete as required at site. 7 450mm nominal dia pipes of 8mm thick complete as required at site. 8 MS Flanges:- Manufacturing, Supplying, fixing & welding of following sizes M.S. Flanges etc complete. as requiredat site. 1200mm dia. & 25mm thickness. 9 350mm dia. & 20mm thickness. 10 400mm dia. & 20mm thickness. 11 450mm dia. & 20mm thickness. 12 MS Bends:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Bends etc. complete. as requiredat site. 1200mm dia. 13 350mm dia. 14 400mm dia. 15 450mm dia. 16 MS Dummy Flanges:-Manufacturing, Supplying & fixing of M.S. Dummy Flanges etc. of following sizes complete as required at site. 1200mm dia. & 25mm thickness. 17 350mm dia. & 16mm thickness. 18 400mm dia. & 25mm thickness. 19 C.I. Sluice Valves:-Providing & Fixing of following sizes Cast Iron Sluice gate Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 20 450 mm nominal dia. 21 C.I. Non Return Valves :-Providing & Fixing of following sizes Cast Iron Non Return Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 22 400 mm nominal dia. 23 Nut/Bolts/Washers:-Manufacturing & Supplying of Nuts,Bolts & Washers etc. of size 7/8 x 6 as required at site. 24 Rubber Gaskets:-Manufacturing, Supplying & Fixingof Rubber Gaskets of thickness 6mm or more for following sizes M.S. Pipelines Flanges as required at site.1200mm nominal dia. 25 350mm nominal dia. 26 400mm nominal dia. 27 450mm nominal dia. 28 Vaccum Pump:-Supplying, Installation, Testing and Commissioning of DV-50 Vaccum Pump sets having C.I. casing and C-40 shaft with 10 H.P. energy efficiency LV motor, 3 phase, 415volt 50hz, 1500RPM +/- 5%, TEFC induction motor mounted on suitable size M.S.base frame coupled on existing foundation withall accessories like ML 1.5 starter, anti vibration mounting pad, coupling, nut-bolts & packing etc. complete in all respect i/c providing, fitting & testing ofheavy class M.S. pipe of 50mm dia.of requiredlength with necessary Gate valve and mountings etc.for chargingof pump sets. ( Pump:- Kirloskar make or as approved by Engineer-in-charge) (Motor:- Kirloskar/Crompton /ABB or as approved by Engineer-in-charge) (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge) 29 Supplying, installation, testing & commissioning of Energy efficient 630 KVA, 11/0.433 KV, 3 phase, 50Hz, Dyn11, outdoor ONAN type, copper wound Transformer with off load tap changing arrangement on HV side , Tapping range +5% to -10% in steps of 2.5%having Cable boxes on HV/LV side suitable for 3 x 240 Sq.mm. XLPE Cable of 11 KV grade with accessories, buckholz relay i/c first filling of filtered dehydrated oil and confirming to IS 335& Transformer losses as per IS 1180 level-2 & as per specification attached complete in all respects as required at site. • Max Continuous Rating = 630 KVA • Voltage Ratio = 11/0.433 KV• Tapping (Range/ Step) off Circuit Tap Changer = +5% to -10% in step of 2.5% off load • Insulation Class = A Class • Application of the Transformer = Distribution• Vector Group = Dyn 11• Temperature Rise at Rated Load over Ambient of 40°/50° C• Cooling = ONAN(Make:- Kirloskar/Schenider/ABB or as approved by Engineer-in-charge) 30 Supplying, Installation, Testing and Commissioning of Indoor Type Floor Mounted metal clad, 11KV VCB Panel with 1 No. VCB for ICOG System (Incoming-Outgoing System), Totally Enclosed. Horizontal drawout, Horizontal/Vertical Isolation type Breaker as per IS 13118 & as ammended upto date and additional specifications as mentioned below, manually charged and motorized /manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated Aluminium Bus Bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 3 x 95 sqmm XLPE 11 KV cable (cable entry frombottom/top/side) (MAKE:- Kirloskar/ L&T/ Crompton/Schenider)1. All CTs and PTs shall be cast resin type.2. 2. All PTs should be Fixed type.Detailed Specifications:-1 Nos. 800A TP Electrically drawout type Vacuum Circuit Breaker, 11KV, 20KA/3 seconds suitable for 630A TP, EDO, 18.4KA/1 second with following accessories:a)Spring Charge Motor, 240V A.C, Closing Coil 24V DC, Shunt Trip Coil 24V DC, Operation Counter with Mechanical ON/OFF Push Buttonb)Mechanical Indicator ON/OFF, Aux. Contacts 4NO + 4NC, Spring Charge/Discharge,Mechanical Spring Charging Device.c)Mechanical Emeregency Push Button2. 1 No. 11 KV / 110V PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-15 kV), digital type, selector switch for voltmeter and protection fuses / MCB for HT metering up to 12 KV on incomer.3. 1 No. Microprocessor based numerical relay with O/L,E/F and S/C protection.4. 1 sets of 3 nos dual core dual ratio CTs 50/50/5/5A of 15 VA burden and accuracy class - 0.5 for metering and class 5P 10 for protection.5. Flush mounted Type High Speed Tripping Relay,6. Flush mounted Type DC Operated Auxiliary relay for Transformer Faults with Three Pair of Relay Element7. 1 Nos. Anti Pumping relay8. Annunciator Set 8 Window Type with Hooter for Fault Indication9. Supplying, Installation, Testing and Commissioning of Power pack with 220 volt AC input & 24 volt DC continuous output suitable for closing / tripping / indication of 1 No. HT Panel Boards with 2 Nos. 12 volts each maintenance free batteries of 100 AH each, charging unit, capacitor bank for emergency delivering for Trip system complete with suitable capacity of Ammeter & voltmeter i/c connections with 2.5 sqmm FRLS insulated copper conductor cable etc. as required. 31 Fabrication Supply Installation Testing and Commissioning of Main L.T Panel suitable for 415 Volt, 3 Phase 4 Wire System, 50Hz AC Supply. Panel Shall be fabricated out of 1.6MM thick CRCA Sheet for load bearing and non load bearing members, Gland Plate shall be fabricated out of 2MM thick CRCA Sheet. Panel shall be Powder coated with RAL 7032 Shade for Doors and Body and have suitable solid links for Incoming ond Outgoing of the ACB with Electrical Grade Aluminium of 1000 Ampere Capacity supported on DMC/SMC Bus Bar Supports. Earthing shall be done with 25 X 5MM G.I Strip running acroos the Panel Length. The Control Wiring for Metering and Display Instruments shall be done with PVC Insulated 1.1KV Grade multi stranded copper wire of 2.5 Sqmm. Proper Ventilation system for heat disipation shall be provided with Panel including ventialtion fan and louvers. The Panel Shall not be less than 1875 X 2000 X 750 m.m or Cm³(H,L&D) The Panel shall be fitted with the following switchgear & instruments as mentioned below:-Incoming:-a)1000A TP ACB, Manually Type with following protection features such as Overload and Shor Circuit protectionb)Digital Type Multifuntion Meter, bearing Cl 1 Accuracy without RS485 Portc)Phase Indication Lamps for R-Phase, Y-Phase and B-Phase, 240V A.Cd)ACB ON and OFF Indication Lampse)6A SP MCB, 10KA Breaking Capacity for Protection and Control Circuitf)1 Set of 1000/5 CT, CL-1.0, 15VA Burden Tape WoundOutgoing:-a)55KW Star Delta Starter with ML4 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosb)30KW Star Delta Starter with ML3 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosc)400A TP MCCB, 36KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nosd)200A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.e)125A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.f) 100A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nos. 32 Supplying, installation, testing & commissioning of Cubical Type Phase sequence corrector suitable for 415 Volt, 3 Phase 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2mm thick CRCA sheet of size for frame work and covers, having Gland plate less than 3mm including cleaning and finishing complete with powder coating in approved shade, having links not less 600A capacity. the Bus Bar support (wherever required) with short curcuit withstand capacity of 31 MVA for 1 sec.Entire panel shall have a common Earth Bus of suitable size at the Rear with 2 Nos. Earth stud, solid connections from main Bus Bar to switch Gears with requires size of Aluminium Bus Bar (wherever required) and control wiring shall be done with 2.5 sq.mm PVC insulated copper conductor single core cables. Including providing and fixing the following switch Gear.A) Materiala) 580A Three Pole Power Contactors, AC3 Duty, Coil voltage 220 V A.C: 2 Nos. (Make:- ABB/L&T/C&S)b) LED type indication Lamps RYB (3 set) Aux. Supply: 220V A.Cc) Control Miniture Circuit Breaker (3 Nos.) SP, 10KA : 6Ad) Single Phase Digital Type Ampere Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 accuracy, CT-Input-5A, Aux. Volt-220V,ACe) Ampere Selector Switch (1No.) Rating : 6Af) Single Phase Digital Type Volt Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 Accuracy, Range:- 0-500 V, Aux. Volt:220V, A.Cg) Voltage Selector Switch (1No.) Rating : 6Ah) Current transformer 600/5A, Single Ratio, Single Core, 1Ø (3 Nos.) , Tape wound, CL-1.0 & 15VAi) LED type Indication LampsON/OFF (2 set) Aux. Supply: 220V A.Cj) Auto/ Manual selector switch (2 Nos.), Rating : 6Ak) Phase Sequence correction relay (1 Nos.) Aux Volt :220V, A.Cl) Audio Indication for Phase sequence Reversal(1 Nos.) Hooter : 220V A.C.m) On Delay Timer (1 Nos.) Aux Volt :220V, A.C 33 SITC of 200KVAR APFC Panel made out of 1.6mm Thick CRCA Sheet duly powder coated complete with suitable size of Al. Bus Bars & internal wiring with suitable size of Copper wire including Providing and Fixing following Switchgear and Metering instruments complete as required. Panel size shall not be less than 1575m.m or Cm³*1900*350.. the Capacitors Shall be Divided as per the mentioned Pattern for 200KVAR SystemA) MaterialMain Incomer:-a) 400A TP MCCB, Thermal based Release with O/L & S/C Protection: 1 Nos.b) Rotary Operating Mechanism: 1 Nos.c) Phase Spreaders: 1 Setd) 12 Stage APFC Relay, Microprocessor Based, with Different Display Parameters.e) Phase Indication Lamps, 220V-240V AC : 3 Nos.2) Outgoing:-a) 63A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 6 Nosb) 40A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.c) 25A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.3) 200 KVAR Capacitor, MPP and Cylindrical Type:-a) 25KVAR Capacitor Bank: 6 Nos.b) 15KVAR Capacitor Bank: 2 Nos.c) 10KVAR Capacitor Bank: 2 Nos.4) Capacitor Duty Contactors of Various Ratings for Capacitor Switching:-a) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 25 or Equivalent : 6 Nosb) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 15 or Equivalent : 2 Nosc) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 10 or Equivalent : 2 Nosd) Side Mounting Block : 10 Nose) Push Button with Element Set for Manual Start & Stop of Capacitor Bank : 10 Setsf) Indication Lights for Capacitor ON Indication : 20 Nos.g) 4 Ventilation Fans with Louvers for Cross Air Ventilation : 1 Nosh) Auto/Manual Selector Switch for Auto/Manual mode of Operation : 1 Nos. 34 Copper Conductor LT Cables:-Supplying, Laying and fixing of following sizes P.V.C. insulated and P.V.C. sheathed/ XLPE CopperConductorarmoured Cable of 1.1 KV grade as per IS:1554 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)4C x 10 sqmm. 35 4C x 120 sqmm 36 4C x 150 sqmm 37 Aluminium Conductor LT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 1.1 KV grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)3.5C x 300 sqmm 38 3.5C x 150 sqmm 39 Aluminium Conductor HT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 11 KV(E) grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. 3.5C x 300 sqmm(Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge) 40 Supply and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 sq. mm 41 4 x 35 sq. mm 42 4 x 10 sq. mm 43 Supply and making outdoor end jointing with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required.3C x 300 sq. mm 44 Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth busbar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way, Double door 45 8way, Double door 46 Supplying and fixing metal box of 100mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 47 Supplying, installation, testing & commissioning of energy efficient LED Flood light luminaries of system wattage 72 watt complete with mounting brackets & accessories i/c connections complete as required.(Make:- Bajaj/Philips/Crompton/Halonix) 48 Supplying and fixing followingpiano type switch/socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch 49 15/16 amp switch 50 3 pin 5/6 amp socket outlet 51 6 pin15/16 amp socket outlet 52 Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. 53 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, , miniature circuit breaker suitable for inductive load of folloeing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole 54 Single pole and neutral 55 Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular plate, sitable GI Box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) 56 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x2.5 sq.m + 1x2.5 sq.m earth wire 57 2 x 4 sq. mm +1 x 4 sq.mmearth wire 58 Supplying, installation, testing and commissioning ofHeavyduty following sizes exhaust fan 900 RPM totally enclosed heavy duty motor with die castaluminium rotor suitable for operation on 240 volts 50 Hz AC single phase Supply including installation of exhaust fan in the existing opening, making good the damages as required. .(Bajaj, Usha, Khaitan, Havells, Orient ) or as approved by Engineer-in-charge.450 mm Sweep 59 Supplying, installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitortype with double ball bearing complete with down rod, canopies, shackles, blades but without regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down rod of standard lenth up to 1 mtr with 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required.(Make:- Bajaj/ Usha/ Khaitan/ Havells/ orientor as approved by Engineer-in-charge) 60 Supplying, installation, testing & commissioning of prewired Indoor decorative 18/20 watt LEDbatten extruded aluminum housing& opal diffuser. IP20 complete with all accessories including connection making etc. as required. (Make:- Bajaj/ Halonix/ Havell’s/ Crompton/ Phillipsor as approved by Engineer-in-charge) 61 Supplying and fixing of following size P.V.C. insulated sheathed /XLPE Aluminum conductor cable of 1.1 KV Grade armoured as per IS:7098 on surface as required. (National,Grandlay, Glouster, Poly-Cab, Phinolex or as approved by Engineer-in-charge). 2 x 10 sq.mm 62 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 63 Providing and fixing 25 x 5 mm G.I.strip on surface or in recess including connection etc. as required. 64 Providing and laying 6 SWG G.I wire on surface or in recess for loop earthing along with existing surface/recessed/conduit/submain wiring/cable etc. as required. 65 Supplying, Installation, Testing and commissioning of 7.5 Tonne capacity Single Girder E.O.T. Crane comprising of Main Girder, End carriages -02 nos with long travel motors – 02 Nos, 01 Nos 5 Tonne capacity Wire Rope Electric Hoist, pendant controlled along with brakes, limit switches and electric panel. All motors i.e. Hoisting/ Lowering, cross travel and long travel shall be compatible with VVVF drive and the speeds can be adjusted from zero to maximum speed. The complete system includes erection of columns, LT Girders, LT rail/ Sq Bar, 01 no DSL system (Shrouded type)(MAKE: - GLOBE/ WH BRADY/ GARLIC) 66 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 150 Watt LED street lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge) 67 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 100 Watt LED Flood lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge). 68 Fabrication & installation of S.S. Bar Screen/ Jaal inside Suction side of Pump Sump in slightly inclined position of required height with M.S. Platform etc. for ease of removal of foreign materials, hyacinth, jute, bags etc. from the suction side completed etc. as required at site.Construction, maintenance and subsequent removal of earthen bundies including cost of excavation earth filling of E.C. bags with earth, stitching and placing in position for care and diversion of all kinds of water entering or flowing in the drain and pumping out surface as well as under groung seepage water to keep the construction area completely dry for execution of entire work including its execution of work in or under water and or liquid mud wherever required with round the clock watch & ward/maintenance of earthen bundies to keep the working area/site dry complete as per specification & direction of Engineer-in-charge. 69 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. 70 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 71 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cementconcrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverableseparately). All works upto plinth level. 72 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 73 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as Nuts, Bolts,fasteners etc.).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
TenderDetail
Loading tenders