View Bid Results For Metal Detector Tenders

We found 2887 Bid Results related to metal detector tenders. You can find Contractor details who won metal detector tenders along with contract details in Bid awards announcements section.

Filters
Stage
2575
197
115
Tender Publishing Platform
2010
877
State / UT
37
328
295
258
183
163
138
133
130
128
127
118
100
88
84
79
75
64
64
47
45
33
26
23
23
19
18
15
14
11
11
10
9
8
7
7
4
2
Contract Value
989
1089
594
205
Publish Date
5
2
1
0
0
Sector
32
1004
278
238
229
169
156
120
105
101
51
51
49
44
36
36
32
27
19
18
16
15
15
12
12
12
8
7
7
6
6
5
3
Ownership
7
1175
1160
386
145
10
8
3
Within keyword
Active filters:
Showing 1–50 of 2887 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 7.69 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 10
Contract Date: Ref. Documents Contract Value : 1.14 Lakh
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
3.
Housing Urban and Rular Development #11475953 Technical Bid
bill of quantities (boq) for renovation of toilets at eight floors (ground floor, 1st, 2nd, 3rd, 4th, 5th, 6th & 7th floors) and pantry at 8th floor of ncdc headquarters building, 4, siri institutional area, august kranti marg, new delhi – 110016 schedule a- civil works sl. no. description of items unit quantity rate amount sub-head : 1 dismantling / demolition works , dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , dismantling tile work in floors,walls and roofs laid in cement mortar including stacking material within 50 metres lead. , dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead , of area 3 sqm. and below , dismantling old plaster or water proofing or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. , demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar , dismantling of flushing cistern of all types c.i./pvc/vitrious china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. , vitreous china water closet indian / european , vitreous china wash basins / urinals , dismantling existing floors of bathrooms and toilets as per instructions. the cost inclusive of stacking of dismantled materials (serviceable material) in good condition and also disposal of broken unserviceable materials at contractors own place. , dismantling of existing cp brass fittings, bottle traps and existing gi & ci pipes / fittings, wherever required in toilet as per instructions. the cost inclusive of stacking of existing brass fittings as per instructions of engineer - in - charge and the location directed by him. , dismantling & removal of malbaa from the sunken areas including stacking of serviceable and unserviceable material separately in the lead of 50 mts.after digging the same till the existing waterproofing is visible. the unserviceable material (inclusive of existing waterproofing, if any, of any nature) shall be removed from the sunken areas and the contractor should stack the same at his own place. sub total 0.0 sub head:2 wood work , providing and fixing wood work in frames of doors, windows, celestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). a. sal wood , providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including isi marked stainless steel butt hinges with necessary screws , extra for providing and fixing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter is to be measured for payment purpose). sub total 0.0 sub head:3 finishing work , providing and applying 12mm cement plaster including making grooves wherever required of mix 1:6 . (1 cement :6 coarse sand) , brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) , providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer-in-charge. , 12.5 mm thick square edge pvc laminated gypsum tile of size 595x595 mm, made of gypsum plasterboard, manufactured from natural gypsum as per is 2095 part i and laminated with white 0.16mm thick fire retardant pvc film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side pvc film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. , providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. size of tile 800x800 (note: a. base rate of tile in the range of rs.90-95/- per sq.ft. b. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 800x800 mm (note: a. base rate of tile in the range of rs.90 -95 per sq.ft. brands: kajaria, euro, rak ceramics, somany or equivalent only ) , providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing of edges to give high gloss finish etc. completeat all levels.granite stone slab of colour black, cherry/ruby red , providing and fixing1500x500 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed towooden cleats with c.p. brass screws and washers complete.mirror make:asahi, saint gobain or equivalent as approved by engineer in charge sub total sub head:4 waterproofing work , providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: (i) ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv)ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). , providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. , supplying and filling in sunken with sand under floors, including watering,ramming, consolidating and dressing complete. sub total 0.0 sub-head : 5 plumbing / sanitary work , providing and fixing white vitreous china pedestal type water closet(european type-one piece) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floorswherever required : w.c. pan with isi marked white solid plastic seat and lid , providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required:white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests , providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (i)white vitreous china wash basin size 630x450 mm with a pair of 15 mm c.p. brass pillar taps , providing and fixing white vitreous china flat back half stall urinal of 710x485x300 mm or 640x370x310 or 610x390x370mm sizes with white pvc automatic flushing cistern, with fittings,standard size c.p. brass flush pipe, spreaders with unions and clamps (allin c.p. brass) with waste fitting as per is : 2556, c.i. trap with outlet gratingand other couplings in c.p. brass, including painting of fittings and cuttingand making good the walls and floors wherever required : range of two half stall urinals with 10 litre p.v.c. automatic flushing cistern , providing and fixing stainless steel a isi 304 (18/8) kitchen sink as peris:13983 with c.i. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the walls wherever required :kitchen sink with drain board 510x1040 mm bowl depth 225 mm , providing and fixing stone slab with table rubbed, edges rounded and polished,of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting achase of appropriate width with chase cutter and embedding the stone in thechase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 6 mm nominal size) as per direction of engineer-in-charge and finished smooth. (granite stone of approved shade) , providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or quivalent make) , 15mm nominal outer dia. pipes , 20mm nominal outer dia. pipes , 32mm nominal outer dia. pipes , 50mm nominal outer dia. pipes , providing and fixing 3 layer pp-r (poly propylene random copolymer)pipes confirming to is:15801 uv stabilized & anti - microbial fusion welded,having thermal stability for hot & cold water supply, including all pp - r plain & brass threaded polypropylene random fittings, including trenching,refilling & testing of joints complete as per direction of engineer-in-charge. (concealed work, including cutting chases and making good the walls etc.following dia mm nominal outer dia pipes),(astral, ashirwad or equivalent make) , 100mm nominal outer dia. pipes , 150mm nominal outer dia. pipes , all internal sanitary works , providing and fixing c.p. brass long nose bib cock of approved quality (15 mm nominal bore) , providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 , providing and fixing brass 2 in 1 pillar cock of approved quality (15 mm nominal bore) sub total 0.0 total sch a 0.0 schedule b- elctrical works sl.no. description unit quantity rate amount (in rs.) , wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable etc. as required.(wire make- havells, polycab, finolex or equivalent. modular switch, socket, box, plate, etc make- havells, roma or equivalent. steel conduit make-bec, unicon or equivalent) , group c , wiring for circuit/ submain wiring along with earth wire with the following sizes of frls/hffr pvc insulated copper conductor, single core cable in surface/recessed steel conduit as required.(wire make- havells, polycab, finolex or equivalent) , 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire , supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.(make- havells, schneider or equivalent) , 250 mm x 300 mm x 100 mm deep , 180 mm x 100 mm x 60 mm deep , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(make- havells, roma or equivalent , 3 pin 5/6 a socket outlet , 5/6 a switch , 15/16 a switch , 6 pin 15/16 a socket outlet , supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc. as required.(make- havells, finolex or equivalent , 8 module (125mmx125mm) , 12 module (200mmx150mm) , 6 module (200mmx75mm) , installation, testing and commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(make- havells, crompton or equivalent , 510 mm sweep , led down lighter (cob type) (system lumen efficacy ≥120 lm/watt ) supplying, installation, testing & commissioning of led recessed/surface down lighter (round / square/ rectangular) cob type of following body material and construction as per is : 10322 with driver as per the requirement with driver efficiency 85%, operating voltage ac 140-270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10%, p. f.≥0.95, ip20, cri 80 , ugr (unified glare rating) 19, flicker free (flicker should be below 5 %), life time (led, driver & electrical circuitry), life time of minimum 50000 burning hours with, 70% of initial lumen maintained till life ends , cct 3000°k / 4000°k / 5700°k /6500°k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted shape size and cct shall be as approved by engineer-in- charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). powder coated die cast /extruded aluminium body including trim with aluminium reflector(make- havells, philips or equivalent) , 12 -15 watt , led batten light (system lumen efficacy ≥120 135 lm/watt) supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency 85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 0c to 40 0c, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f.≥0.95, ip20, cri 80, flicker free (flicker should be below 5 %), life time (led,driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000°k / 4000°k / 5700°k /6500°k 46 delhi schedule of rates (e&m)-2025(as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy ≥120 135 lm/watt output. lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c).powder coated die cast /extruded aluminium body (thickness 1.20 mm)(make- havells, philips or equivalent) , 18- 22 watt , led strip light (make- philips, wipro or equivalent) , automatic hand dryer (make- dolphy, euronics or equivalent) , automatic touchless toilet urinal sensor alongwith solenoid valve, flexible hose, etc(make- parryware, jaquar or equivalent) total sch b total total (sch a+schb) 0.0 say rs.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 5
Contract Date: Ref. Documents Contract Value : 63,485
Statutory Bodies & Commissions/Committees No of Bidders 6
Maharashtra View Result →
6.
Science and Technology #11440503 Technical Bid
Tender for Earth Work , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lif. , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Cement Concrete (Cast In Situ) , Providing And Laying In Position Excluding Cement Concrete Of Level: Specified Grade The Cost Of Centering And Shuttering - All Work Up To Plinth 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources: 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Stone Work , Coursed Rubble Masonry (Second Sort) With Hard Stone In Foundation & Plinth With :Cement Mortar 1:6(1 Cement : 6 Coarse Sand) , Cladding Work , Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge,Granite Work , Wood And P. V. C. Work , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). , Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For (I) Sites With Basic Wind Speed 45 M/Sec As Per Is 875 - Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speedscasement Window Double Panels With Fixed Mullion With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above) & Sash (39 Mm & Above) X (60 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre). , Steel Work , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Flooring , Providing And Laying Vitrified Tiles In Floor In Diferent Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Of Tile 600 X 600 Mm , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Finishing , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Coarse Sand) , 6 Mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams. , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 12 Mm Thick Plain Cement Mortar Bands In Cement Mortar 1:4 (1 Cement: 4 Fine Sand):Moulded Band , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Itr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work , French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.Two Coats , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Dismantling And Demolishing , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Aluminium Work , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete.Upto 5 Mm Depth And 5 Mm Width , Market Rate Items , Provinding Precast Cement Concrete Solid Block Masonry Including Hoisting And Setting In Position With Cement Mortar 1:6 (Cement :6 Coarse Sand) Completed As Per The Direction Of Engineer In Charge As Per Site Condition , Providing And Fixing 5 Mm Thick Clear Transparent Acrylic Sheet Of Approved Brand And Manufacture For Fixed Curved Portions In Openings, Including Epdm Rubber/Neoprene Gasket And All Necessary Accessories, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Electrical Work , Laying And Fixing Of One No Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq.Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 16 Sq. Mm (25Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs As Required . , Supplying And Fixing 6 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator. , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole And Neutral , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 6 Module (200Mmx125mm) , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15/16 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , 2M Stepped Type Electronic Fan Regulator , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fanpoint/ Exhaust Fan Point/ Call Bell Point (Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit,And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. (Group-C) , Providing And Fixing 6 Swg Dia G.I Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying, Installation, Testing & Commissioning Of Photo Electronic Smoke Detector With Builtin Led And Mounting Base Plate Suitable With Ms Junction Box For Operation On 12V / 24V Complete With All Connections Etc. As Required. , Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. , Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With Upto 32A, 240 V, C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 32 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Spmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Speed Control Compitable For Electronic Type Regulator And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Including Fixing Fan Hook In Ceiling Complete As Required. , Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft.,40W Of Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm) Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency 85%, Operating Voltage Ac 140 270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10% , P. F.≥0.95, Ip20, Cri 80, Ugr (Unified Glare Rating) 19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With, 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 5700°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. System Lumen Efficacy ≥105 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. , Supplying And Fixing Of 25Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing 1 Run Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended/Surface Mount From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. , Supplying And Fixing Fp Mcb Sheet Steel Enclosure With Din Rail On Surface / Recess Etc. As Required. , Supplying & Fixing Of 4Pole, 63 A Rating, 415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 16Sq.Mm, Aluminium , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 6Sq.Mm, Copper , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,3C X 4 Sq.Mm, Copper , Supply And Laying Of Un Armoured Copper Single Core 10 Sq.Mm Flexible Cable With Annealed Copper Conductor In Suitable Size Hdpe Pipe In Ground/ On Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.3 X 4 Sq.Mm , Supply ,Installation, Testing And Commissioning Of 2 Tr/24000Btu Per Hour And Bee-5 Star Rated Wall Mounted Inverter Type Hi Wall Split Cooling Air Conditioner Having Wireless Remote Controller, Hermetically Sealed/Scroll/Rotary Compressor And Eco Friendly Refrigerant,Initial Charge Of Refrigerant,Condensor And Evaporator Coils Of Copper Material, Air Filter With Auto Swing & Auto Restart Features, Suitable For Operation On 230V, Single Phase, 50Hz, Ac Power Supply. The Indoor Unit Shall Be Fixed Rigidly On Wall Using Necessary Frame, The Outdoor Unit Shall Be Mounted On Wall Or Floor Using Suitable Powder Coated Ms Angle Frame As Required. Including Clamps, Bolts, Nuts,Vibrating Dampers, Laying Of 3 Meter Standard Length Of Copper Refrigerant Piping With 3 Meter Pvc Covering Pipe, 3 Meter Drain Piping, Wrapping Tape And Necessary Insulation ,Electrical Flexible Cable Connectivity Between Indoor And Outdoor Unit. Necessary Drilling Of Hole And Finishing The Same To Match For The Surrounding As Required. , Supplying And Fixing Of Frp Box 200Mmx140mmx95mm Size (Nominal Size) On Surface With Hinged Door With Suitable Grounding Copper Bar Link With Holes Fitted Inside The Box Etc. As Required. , Supplying And Fixing Of Dual Rj 45 / Io Outlet On Existing Modular Switch Plate. , Supply,Installation,Testing And Commissioning Of Maintenace Free Earth Pit Of Single Pipe Technology Copper Pipe Of 2000Mm Long (Min), Outer Dia 50 Mm, Wall Thickness 1.2Mm(Min), Filled With Highly Conducting Metallic Compounds With The Permanent Sealing At Both The Ends And Lead Terminal Of 50 X 10 Mm Size At The Top The Length Of The Electrode Shall Be 2000 Mm Excluding The Lead Terminal And The Length Of The Lead Terminal At The Top Shall Be Minimum 50Mm. To Ensure The Moisture Content And Electrical Conductivity, Resistance Lowering Grounding Minerals Shall Be Filled Around The Electrode Of (Min25 Kg) .Heavy Duty Weather Proof Plastic Earth Pit Chamber With Cover Of Dimension 300 Mm Dia (Top), 260 Mm Dia(Bottom) And 300 Mm (Height) Shall Be Used, Numbering Of Pit And Measured Value Written With Weather Proof Painting Or Stickering. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Contract Date: Ref. Documents Contract Value : 7.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 6.69 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Jammu and Kashmir View Result →
14.
Health and Family Welfare #11352441 AOC
Providing Fire Fighting Equipment At Area Hospital Jagtial In Jagtial District-6.00 Supply And Installation Testing And Commissioning Of 6Watt 180Mm Dia Recessed / Surface Mounted White Color Speakers ( Along With Junction Boxes To Be Used In No False Ceiling Area ) Makes: Philips / Ahuja / Bosch / Eqvt. 1.00 Supply Installation Testing And Commissioning Of Amplifier With Inbuilt 240Watts Amplifier With Emergency Microphone Along With All Interconnections Suitable To Integrate With Fire Alarm Panel Etc Complete For Finished Item Of Work Makes: Philips / Ahuja / Bosch / Eqvt. 4.00 Supply Installation Testing And Commissioning Of 4 Mic With All Accessories Etc Complete For Finshed Item Of Work. Makes: Philips / Ahuja / Bosch / Eqvt. 350.00 Supply And Laying Of Shielded Twin Twisted Pair 1.0 Sqmm Cable In Existing Conduit Etc Complete For Finished Item Of Work Makes: Lapp / Polycab / Thermopads / Eqvt. 200.00 Supply And Laying Of Isi 25Mm Outer Dia Medium Grade With Is:9537 Part 3 Regid Pvc Pipe Concealed In Wall With All Required Pvc / Metallic Junction Boxes Including Masonary Work And Labour Charges Etc., Makes : Sudhakar / Finolex / Modi / Vip / Precision / Universal / Million Plast. 6.00 Supply And Fixing Of Escape Signage Boards In Rigid Photo Luminecent Based Glow In Dark Rigid Sheet With High Intensity Luminous Properties With Specificaiton Of Cease Fire Or Its Equivalent Make Model-1Es01 6.00 Supply And Installation Of Addressable Analogue Manual Call Point With Resetable Flexible Element To Initiate Alaram Including The Cost Of Mounting Accessories Etc. Complete. Makes: Notifier / Edwards 1.00 Supply, Installation, Testing And Commissioning Of Wall Mounting 2 Loop Micro Processor Based Analog Addressable Fire Control Panel Expandable By Minimum 2 Additional Loops With Minimum 80 Character Lcd Display 4 Access Levels 1000 Events, Historical Logging, Flash E-Prom, 240 Volts A C Power Supply, Automatic Battery Charger, 24V Sla Batteries Suitable For Operating The Entire System Including Tack Back Units And The Hooters / Strobes For A Minimum Of 4 Hours In Battery Condition The Panel Shall Have Suitable Power Amplifiers For Hooter / Strobes The Panel Shall Be Capable Beeing Integrated With The Bms System And Shall Include Cost Of Supply, Installation Of Any Additional Modules Or Interfaces Required For The Same. The Panel Shall Be Completed As Per The Specification And As Required For Fixing Of Above Micro Processor Based Fire Alarm Control Panel With Zonal Indictions And Battery Back Up As Per Detailed Specifications. Makes: Notifier / Edwards 6.00 Supply And Fixing Of Addressable Wall Mounting Strobes Cum Hooters Including The Cost Of Mounting Accessories Complete As Per Specifications And As Required Including Testing And Commissioning. Makes: Notifier / Edwards 6.00 Supply And Installation Of Intalligent Analogue Addressable Multi Criterion Detectors Below False Ceiling / On Ceiling Including The Cost Of Base Plate. 75Mm Dia Ms Outlet Box For Fixing Of The Detector Base, Mounting Accessories Etc., Complete As Per Specifications And As Required. Makes: Notifier / Edwards 6.00 Supply And Installation Of Response Indicators For Above False Ceiling Detectors. 120.00 Supply Of 2 Core X 1.5Sqmm Frls Armoured Copper Cable As Per Is. 7098 / Part-I / 1988 Including All Taxes Etc., Complete. Makes: Universal / Unicab / Polycab / Finolex / Havells. 32.00 Supply And Fixing Of Ceiling Mounted Abc Map 90, 5 Kg Stored Pressure Type, Pressure Gauge, Gross Wt. 7.7 Kg, Empty Wt. 2.7 Kg, Can Ht264mm , Dia 240Mm, Discharge Time : Less Than 8 Sec, Is 15683 : 2006 Auto Discharge Mechanism On Temperature Rise, Applicable On A, B, C, & Electrically - Started Fires, Can Construction: Forging & Machining, Internal Coating Of Can: Epoxy Power Coating, External Coating Of Can: Epoxy Polyster Powder Coating, Sheet Metal Thickness:1.60Mm , Helium Leakage Detection Tested, Isi Approved With 5 Years Warranty ( Cease Fire / Minimax Make ) Including Transportation, All Taxes And All Labour Charges Etc Complete. 4.00 Supply And Fixing Of 4Nos Of 9 Ltrs Capacity Round Bottom Bucket With Sand, Duly Painted With Enamel White Inside & Red Out Side And Letter Fire With Black Colour. 4.00 Supply Anmd Fixing Of Fire Bucket Stand Fabricated By M.S. Angles To Install For Two Numbers Of Buckets As Per Local Fire Officers Standards.
Contract Date: Ref. Documents Contract Value : 5.24 Lakh
Government Departments No of Bidders 1
15.
Health and Family Welfare #11352436 AOC
Providing Of Fire Fighting Equipment At Ah Sircilla In Rajanna Sircilla District.-8.00 Supply And Installation Testing And Commissioning Of 6Watt 180Mm Dia Recessed / Surface Mounted White Color Speakers ( Along With Junction Boxes To Be Used In No False Ceiling Area ) Makes: Philips / Ahuja / Bosch / Eqvt. 1.00 Supply Installation Testing And Commissioning Of Amplifier With Inbuilt 240Watts Amplifier With Emergency Microphone Along With All Interconnections Suitable To Integrate With Fire Alarm Panel Etc Complete For Finished Item Of Work Makes: Philips / Ahuja / Bosch / Eqvt. 4.00 Supply Installation Testing And Commissioning Of 4 Mic With All Accessories Etc Complete For Finshed Item Of Work. Makes: Philips / Ahuja / Bosch / Eqvt. 400.00 Supply And Laying Of Shielded Twin Twisted Pair 1.0 Sqmm Cable In Existing Conduit Etc Complete For Finished Item Of Work Makes: Lapp / Polycab / Thermopads / Eqvt. 300.00 Supply And Laying Of Isi 25Mm Outer Dia Medium Grade With Is:9537 Part 3 Regid Pvc Pipe Concealed In Wall With All Required Pvc / Metallic Junction Boxes Including Masonary Work And Labour Charges Etc., Makes : Sudhakar / Finolex / Modi / Vip / Precision / Universal / Million Plast. 6.00 Supply And Fixing Of Escape Signage Boards In Rigid Photo Luminecent Based Glow In Dark Rigid Sheet With High Intensity Luminous Properties With Specificaiton Of Cease Fire Or Its Equivalent Make Model-1Es01 6.00 Supply And Installation Of Addressable Analogue Manual Call Point With Resetable Flexible Element To Initiate Alaram Including The Cost Of Mounting Accessories Etc. Complete. Makes: Notifier / Edwards 1.00 Supply, Installation, Testing And Commissioning Of Wall Mounting 2 Loop Micro Processor Based Analog Addressable Fire Control Panel Expandable By Minimum 2 Additional Loops With Minimum 80 Character Lcd Display 4 Access Levels 1000 Events, Historical Logging, Flash E-Prom, 240 Volts A C Power Supply, Automatic Battery Charger, 24V Sla Batteries Suitable For Operating The Entire System Including Tack Back Units And The Hooters / Strobes For A Minimum Of 4 Hours In Battery Condition The Panel Shall Have Suitable Power Amplifiers For Hooter / Strobes The Panel Shall Be Capable Beeing Integrated With The Bms System And Shall Include Cost Of Supply, Installation Of Any Additional Modules Or Interfaces Required For The Same. The Panel Shall Be Completed As Per The Specification And As Required For Fixing Of Above Micro Processor Based Fire Alarm Control Panel With Zonal Indictions And Battery Back Up As Per Detailed Specifications. Makes: Notifier / Edwards 6.00 Supply And Fixing Of Addressable Wall Mounting Strobes Cum Hooters Including The Cost Of Mounting Accessories Complete As Per Specifications And As Required Including Testing And Commissioning. Makes: Notifier / Edwards 6.00 Supply And Installation Of Intalligent Analogue Addressable Multi Criterion Detectors Below False Ceiling / On Ceiling Including The Cost Of Base Plate. 75Mm Dia Ms Outlet Box For Fixing Of The Detector Base, Mounting Accessories Etc., Complete As Per Specifications And As Required. Makes: Notifier / Edwards 6.00 Supply And Installation Of Response Indicators For Above False Ceiling Detectors. 165.00 Supply Of 2 Core X 1.5Sqmm Frls Armoured Copper Cable As Per Is. 7098 / Part-I / 1988 Including All Taxes Etc., Complete. Makes: Universal / Unicab / Polycab / Finolex / Havells. 30.00 Supply And Fixing Of Ceiling Mounted Abc Map 90, 5 Kg Stored Pressure Type, Pressure Gauge, Gross Wt. 7.7 Kg, Empty Wt. 2.7 Kg, Can Ht264mm , Dia 240Mm, Discharge Time : Less Than 8 Sec, Is 15683 : 2006 Auto Discharge Mechanism On Temperature Rise, Applicable On A, B, C, & Electrically - Started Fires, Can Construction: Forging & Machining, Internal Coating Of Can: Epoxy Power Coating, External Coating Of Can: Epoxy Polyster Powder Coating, Sheet Metal Thickness:1.60Mm , Helium Leakage Detection Tested, Isi Approved With 5 Years Warranty ( Cease Fire / Minimax Make ) Including Transportation, All Taxes And All Labour Charges Etc Complete. 4.00 Supply And Fixing Of 4Nos Of 9 Ltrs Capacity Round Bottom Bucket With Sand, Duly Painted With Enamel White Inside & Red Out Side And Letter Fire With Black Colour. 4.00 Supply Anmd Fixing Of Fire Bucket Stand Fabricated By M.S. Angles To Install For Two Numbers Of Buckets As Per Local Fire Officers Standards.
Contract Date: Ref. Documents Contract Value : 5.36 Lakh
Government Departments No of Bidders 1
16.
Drinking Water Supply and Sanitation #11348134 Technical Bid
Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
19.
Defence #11329394 AOC
Bid Are Invited For 1 Pvc Pendent Holder. 2 One Way. Bed Switch. 3 Single Pole 10 Amps, Two Way Switch, Isi Marked. Modular Type. 4 Modular Bell Push Switch. 5 Modular Blanking Plate. 6 Single Pole 25 Amps, One Way Modular Switch, Isi Marked. 7 2 Module, Modular Base And Cover Plate. 8 3 Module, Modular Base And Cover Plate. 9 4 Module, Modular Base And Cover Plate. 10 6 Module, Modular Base And Cover Plate. 11 12 Module, Modular Base And Cover Plate. 12 Flame Retardant, Pvc Electrical Insulation Tapes 6 Mtr X 1.8 Cm Long. 13 Pvc Gitt, Pvc Rawal Plug, Pvc Fastener 38 To 40Mm Long. 14 3 Mm Thick Phenolic Laminated Sheet. 15 1.5 Sq. Mm. Frls Or Hffr Single Core, Multi Strand Copper Conductor, Pvc Insulated Cable Suitable Upto 1100 Volts. 16 4.0 Sq. Mm. Frls Or Hffr Single Core, Multi Strand Copper Conductor, Pvc Insulated Cable Suitable Upto 1100 Volts. 17 6.0 Sq. Mm. Frls Or Hffr Single Core, Multi Strand Copper Conductor, Pvc Insulated Cable Suitable Upto 1100 Volts. 18 Modular Mcb Single Pole 25 Amp C Curve, 3 Ka Breaking Capacity. 19 Pin Anchor Fastener 6 X 50 20 Pin Anchor Fastener 8 X 50 21 Pin Anchor Fastener 8 X 75 22 Pin Anchor Fastener 10 X 100 23 Ring Hook Fastener M-8 24 Ring Hook Fastener M-10 25 Wedge Anchor Fastener 8 Mm X 75 Mm 26 3 Mm Thick Pvc Or Phenolic Laminated Round Sheet Cover Minimum170 Mm Dia For Fan Box. 27 3 Mm Thick Pvc Or Phenolic Laminated Round Sheet Cover 100 Mm Dia. 28 3 Module , Pvc Surface Modular Box For Following Module. 29 6 Module , Pvc Surface Modular Box For Following Module. 30 Bee 5 Star Rating, 25 Litres Capacity Water Storage Heater, With Protection Against Over Heating, Multifunction Safety Valve And External Adjustable Thermostat. 31 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current Motor. 32 Supply Of 400 Mm, Single Phase Wall Mounting Fan. 33 Fresh Air Fan With Louver Shutter 250 Mm Sweep. 34 230 Mm Sweep, 1400 Rpm , Single Phase, Metallic Exhaust Fan Conforming To Is 2312 -1967. 35 Metallic Louvred Shutter Suitable For 300 Mm Sizes Exhaust Fan. 36 Metallic Louvred Shutter Suitable For 380 Mm Sizes Exhaust Fan. 37 18- 22 Watt Led Surface Mounted Batten Light. 38 40 Watt Led Surface Mounted Batten Light. 39 5-7 Watt Led Recessed Orsurface Down Lighter. 40 12 -15 Watt Led Recessed Or Surface Down Lighter. 41 18 Watt Led Recessed Or Surface Down Lighter. 42 Led Batten Emergency ,Inverter, Luminaire Minimum System Lumen Output Of 2000 Lumen. 43 Utility Knife Tapaia Uk-3 44 Spare Blade Ub-10 For Utility Knife Uk-3 Taparia 45 Flexible Connection Pipe 450Mm Long, Metal Braided Hoses . 46 Measuring Tape, Length Of The Tape Is 30 M. The Width Of The Blade Is 13Mm. 47 Casing Capping Clip 48 Pvc Nail Clip 20 Mm Double Nail. 49 Aluminium Paint . 50 Red Oxide Metal Primer. 51 Paint Thinner. 52 Paint Brush 2 Inch 53 Paint Brush 3 Inch 54 Wooden Screw 35 X 8 55 Wooden Screw 50 X 8 56 Dry Wall Gypsum Screw 0.75 Inch 57 Dry Wall Gypsum Screw 1Inch 58 Dry Wall Gypsum Screw 1.5 Inch 59 10 Amp, 12 Way, Pvc Strip Connector. 60 15 Amp, 12 Way, Pvc Strip Connector. 61 Iron Drill Bit Set Having 25 Pcs . 62 Self Supported Frp Platform Step Ladder 63 Multifunction Testers . 64 400 Amp 04 Pole Power Contactor. 65 16 Sq Mm Aluminium Flat Thimble 66 25 Sq Mm Aluminium Flat Thimble 67 50 Sq Mm Aluminium Flat Thimble 68 70 Sq Mm Aluminium Flat Thimble 69 95 Sq Mm Aluminium Flat Thimble 70 120 Sq Mm Aluminium Flat Thimble 71 150 Sqmm Aluminium Flat Thimble 72 185 Sq Mm Aluminium Flat Thimble 73 240 Sq Mm Aluminium Flat Thimble 74 300 Sq Mm Aluminium Flat Thimble 75 400 Sq Mm Aluminium Flat Thimble 76 16 Sq Mm Aluminium Ferrule 77 25 Sq Mm Aluminium Ferrule 78 35 Sq Mm Aluminium Ferrule 79 50 Sq Mm Aluminium Ferrule 80 70 Sq Mm Aluminium Ferrule 81 70 Watt Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Driver . 82 150 Watt Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Driver. 83 45 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver . 84 72 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver. 85 90 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver. 86 150 Watt Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver As Per The Requirement With Driver. 87 10 To 11 Watt, 0.6 Metre Nominal Size Led Bollard Light Fitting Complete With Led Module. 88 25-Watt Led-Based Post-Top Luminaire, Ip 65, With Die-Cast Aluminium Spigot Housing, Complete With Diffuser, Led Module, Driver With Surge Protection . 89 10 Watt To 12 Watt Spike Led Light With Aluminium Housing, Ip66 Having Tiltable Feature To Throw Light In The Desired Direction. 90 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 2 X 16 Sq. Mm Sq. Mm 1.1 Kv Grade Cable. 91 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 2 X 25 Sq. Mm Sq. Mm 1.1 Kv Grade Cable. 92 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 3.5 X 35 Sq. Mm Sq. Mm 1.1 Kv Grade Cable. 93 Straight Through Cable Jointing Kit With Heat Shrinkable Kit With Ferrules For 1.1 Kv Grade Cable. Size 3.5 X 300 Sq. Mm 1.1 Kv Grade Cable. 94 Cable Junction Boxes, Ip 66 Weather Proof, Size 205 Mm X 255 Mm X 112 Mm, With Terminals Suitable For 16 Sq Mm Cable. 95 4 Inch Cutting Wheel For Metal Suitable For 4 Inch Angle Grinder. 96 1.5 Volt Alkaline Non-Rechargeable, Type Battery, Size- Aaa. 97 1.5 Volt Alkaline Non-Rechargeable, Type Battery, Size- Aa. 98 9 Volts Alkaline Non-Rechargeable Battery. 99 23A, 12V Alkaline Battery. 100 Led Rope Light, 10 Watt Per Metre Or 120 Led Per Metre, In Various Colors, Ip65 Rating, With Adopter. 101 Supplying Of Adapter For Led Rope Light. 102 Led Rope Light, 6 W Per Mtr, Ip65, Tri-Color. 18 Meter. 103 Supplying Pidilite Wd 40 Mechinical Contact Cleaner In 500 Ml Can With Straw Spray. 104 2 X 16 Sq Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is 7098 Part 1 1988 With Upto Date Amendments. 105 2 X 25 Sq Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is 7098 Part 1 1988 With Upto Date Amendments. 106 3.5 X 35 Sq. Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade, Confirming To Is 7098 Part 1 1988 With Up To Date Amendments. 107 3.5 X 120 Sq. Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade, Confirming To Is 7098 Part 1 1988 With Up To Date Amendments. 108 3.5 X 400 Sq. Mm Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade, Confirming To Is 7098 Part 1 1988 With Up To Date Amendments. 109 Socket Tester To Verify That The Wall Socket Is Correctly Wired And To Check For Common Faults. 110 M-Seal - Regular Epoxy Compound. 111 Pu Foam Insulation Sealant 750 Ml 112 Distilled Water, 5 Liters . 113 Weatherproof, Ip66, Wire Connector With Plug And Socket Suitable For 4 Sq Mm Copper Cable. 114 Digital Earth Resistancetester. 115 Pvc Weatherproof, Ip65, 8 Module Mcb Db With Din Rail. 116 Wall-Mounted Voltage Stabilizer, Suitable For 1.5 Ton Split Air Conditioner. 117 Wall-Mounted Voltage Stabilizer, Suitable For 2 Ton Split Air Conditioner. 118 Blue Plastic Crate, 4 Litre Capacity, Size 300 X 200 X 100 Mm, Suitable For Material Storage. 119 Pvc Weatherproof Switch Box, Ip66 Rated. 120 A Power Adaptor With In Built Rcd 30 Ma 121 Robustt Caution Tape 3 Inches X 130 Mt, Pack Of 1, White And Red Pvc Material, Barrication Tape. 122 Polypropylene Floor Standing Caution Sign Board 123 Stainless Steel Clip For Fixing Led Batten As Per Sample Provided By Department. 124 Waterproof Paint Marke. 125 15A Insulated Test Lead Cable With Dual-Ended Insulated Crocodile Clips, Suitable For Electrical Testing. Set Of 5 Pc. 126 Plastic Step Stool, Nominal Dimensions Width 57 Cm, Depth 54 Cm, Height 60 Cm. 127 30W 220V Round Corded Soldering Iron With Led Worklight . 6 Months Warranty. 128 Solder Paste Flux Pack -50 Gm 129 Lead-Free Soldering Wire, 0.8 Mm Diameter, Suitable For Electronic And Electrical Soldering And Component Repair. 20-Gram Pack. 130 Cleaning Cloth Towels, Material 100 Percent Cotton. 131 Microfiber Multi-Purpose Cleaning Wipe. 132 Contactless Surface Temperature Detector. 133 Pvc Plastic Pipe Cutter, Cutting Capacity Up To 42 Mm 134 Hss Bi-Metal Holesaw Set, 20 To 64 Mm Diameter Hole Saw Sizes 20, 25, 32, 38, 51, And 64 Mm. 135 Plastic Tool Box With Organizer, Height 150 Mm, Width 190 Mm, Length 335 Mm 136 High Carbon Steel Shovel With Wooden Handle. 137 Hoe Powrahs 138 High Tempered Iron Pickaxe 139 Aluminium Self Supporting Type Tower Ladder Extendable
Contract Date: Ref. Documents Contract Value : 44.45 Lakh
Government Departments No of Bidders 6
Contract Date: Ref. Documents Contract Value : 47.64 Lakh
Government Departments No of Bidders 10
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 12,796
Statutory Bodies & Commissions/Committees No of Bidders 8
22.
Educational and Research Institute #11316829 AOC
Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Construction; Construction; Comprehensive Maintenance Contract (Cmc); Not Applicable; Yes - Providing And Laying Of Rcc Platform To Raised Flooring With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Aggregate : 4 Aggregate ) With Specific Area As Per Required And As Per Direction Of Site In Charge , Supplying, Fitting And Fixing 8Mm Thick Laminated Wooden Flooring Work Conforming To En13329:2006 With Plank Size Not Iess Than 1200 Mm X 190 Mm (With Unilin/Tongue-Groove Locking Arrangement) Having 0.2Mm Thick Top Abrasive Layer Over A Decorative Layer Followed By A High-Density Fibreboard (Hdf) Having Density > 850 Kg/M3 Substrate Core Over A Resin Saturated Backing Layer And Installing Through Unilin Or Tongue- Groove System (Having Locking Strength Not Less Than 1000 Kg/M) Over A 2 Mm Thick Under Layer Polyurethane Foam On Polythene Sheet 250 Micron, Over A Smooth, Flat, Hard Subfloor Free From Moisture (< 8%), Grease Etc. Complete In All Respect With Requisite Accessories Like End Profile, Transition Profile, Reducer T Profile Etc. Wherever Required And Preparation Of Base Including All Other Incidental Works As Per Direction & Satisfaction Of Engineer In Charge. Cost Of Laminate Floor Accessories Only (Skirting ,End Edge, T- Moulding, Reducer) Shall Have To Be Added Separately, Wherever Required As Directed By Engineer In Charge In Approved Shade & Colour As Per Drawing Specification ( Including All Lead And Lift )(Basic Rate :-Rs 180/- Per Sft) , Supplying Laminate Floor Accessories (Skirting, End Edge, T Moulding Reducer ) To 8Mm Thick Laminated Wooden Flooring Work Conforming To En13329:2006 With Plank Size Not Iess Than 1200Mmx 190 Mm (With Unilin/Tongue-Groove Locking Arrangement) Having 0.2Mm Thick Top Abrasive Layer Over A Decorative Layer Followed By A High-Density Fiberboard (Hdf) Having Density > 840 Kg/M3 Substrate Core Over A Rasin Saturated Backing Layer And Installing Through Unilin Or Tongue- Groove System (Having Locking Strength Not Less Than 1000 Kg/M) Over A 2 Mm Thk Under Layer Polyurethane Foam On Polythene Sheet 250 , Providing And Fixing Wall Panelling With Wpc Luvar Or Fluter Panel With 12 Mm Thick , Approved Colour , Pattern , Design , Shade, Fixing With Required 12 Mm Ply For Support As Per Required Area And As Per Direction Of Site In Charge , Providing And Fixing 15 Mm Thick Densified Tegular Edged Eco Friendly Light Weight Calcium Silicate False Ceiling Tiles Of Approved Texture Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections (Galvanising @ 120 Grams Per Sqm Including Both Side) Consisting Of Main T Runner Suitably Spaced At Joints To Get Required Length And Of Size 24X38 Mm Made From 0.33 Mm Thick (Minimum) Sheet, Spaced 1200 Mm Centre To Centre, And Cross T Of Size 24X28 Mm Made Out Of 0.33 Mm (Minimum) Sheet, 1200 Mm Long Spaced Between Maint At 600 Mm Centre To Centre To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24 X28 Mm Made Of 0.33 Mm Thick (Minimum) Sheet To Be Inter Locked At Middle Of The 1200X 600 Mm Panel To From Grid Of Size 600X600 Mm, Resting On Periphery Walls /Partitions On A Perimeter Wall Angle Pre-Coated Steel Of Size(24X24x3000 Mm Made Of 0.40 Mm Thick (Minimum) Sheet With The Help Of Rawl Plugs At 450 Mm Centre To Centre With 25 Mm Long Dry Wall Screws @ 230 Mm Interval And Laying 15 Mm Thick Densified Edges Calcium Silicate Ceiling Tiles Of Approved Texture In The Grid, Including, Cutting/ Making Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc., Wherever Required. , Providing And Fixing Electrical Work For Conference Room Including Wiring Inside Room Floor And Provision For Ac And Celling Light 600 X 600 Roof 36 Watt With Switches And Socket Power , And Underground Wiring With In Room As Per Required Including 2.5 To 6Mm Copper Wire As Where Required , Modular Switches And Power Socket With 4 Nos Wall Fan , Electrical Wiring With Room Complete As Per Direction Of Site In Charge , Providing And Fixing Cupboard Shutter With 19 Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2 Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges (Hydraulic Type) Etc. Complete As Per Direction Of Engineer-In-Charge. (Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately) , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. , Providing And Fixing 18 Mm Thick Plywood For Extended Floor Area As Per Required Size With Proper Fixing With Nails And Fastner On Floor Or Wall As Per Direction , Providing And Fixing Computer Table For Lab Using 19 Mm Thick Hdmr Board With 1 Mm Thick Top Laminate With Required Lenth 5X.075X0.9 Mtr With Partiton Every 900 Mm Both Side 1Mm Laminate , With Wooden Stand For Foot Rest, And Fixing With Fastner, Nail , Edge Bending 19Mm Tape Matching Colour , Rawl,Plug, Stright With Proper Fixing As Per Direction Of Site In Charge, , Removing And Re Fixing Wooden Door As Per Required Size With Change Of Ss Hinges Fixing 35Mm Thick Screw With Fixig Margin As Per Required Area As Per Direction Of Site In Charge , Any Other Work Paid As Per Civil 2023 Dsr Actual Rate .. And As Per Cpwd Rule,Note: The Payment Of Dsr23 Items (Which Are Inclusive Of Gst) Shall Beregulated As Below:Rate Of Dsr23 Items & 27.0 Additional Miscellaneousitems I/C Gst = X
Contract Date: Ref. Documents Contract Value : 39.65 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Jun 17, 2026 Contract Value : 8.13 Lakh
Local Bodies No of Bidders 2
26.
Communications and Information Technology  #11297723 AOC
Bids Are Invited For SITC of LT Panel having 2 nos 250A 4pole MCCBs as incomers and 8 nos 100A 4pole MCCBs for outgoings , SITC of LT Panel having 2 nos 100 A 4 pole MCCBs as incomers or outgoings , Point wiring with 1.5 sq mm FRLS PVC insulated Cu cond single core cable in steel conduit with modular switch plate and modular GI _Group C , Wiring for circuit or submain wiring with the 2 x 1.5 sq mm plus 1 x 1.5 sq mm earth wire , Wiring for circuit or submain wiring with the 4 x 1.5 sq mm plus 2 x 1.5 sq mm earth wire , Wiring for circuit or submain wiring with the 6 x 1.5 sq mm plus 3 x 1.5 sq mm earth wire , Wiring for circuit or submain wiring with the 2 x 2 .5 sq mm plus 1 x 2.5 sq mm earth wire , Wiring for circuit or submain wiring with the 4 x 2.5 sq mm plus 2 x 2.5 sq mm earth wire , Wiring for circuit or submain wiring with the 2 x 6 sq mm plus 1 x 6 sq mm earth wire , Wiring for light or power plug with the 2 x 4 sq mm alongwith 1 x 4 sq mm earth wire , Wiring for light or power plug with the 4 x 4 sq mm alongwith 2 x 4 sq mm earth wire , S and F 20 mm steel conduit , S and F 25 mm steel conduit , S and D of 1 x 1.5 sq mm FRLS PVC insulated Cu conductor , S and D of 2 x 1.5 sq mm FRLS PVC insulated Cu conductor , S and D of 3 x 1.5 sq mm FRLS PVC insulated Cu conductor , S and D of 2 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 3 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 6 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 9 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 12 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 24 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 36 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 48 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 54 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 3 x 4 sq mm FRLS PVC insulated Cu conductor , S and D of 6 x 4 sq mm FRLS PVC insulated Cu conductor , Sand F of GI box with modular plate and cover including P and F modular 3 pin 5 or 6 amps socket outlet and 5 or 6 amps switch , S and F of GI box with modular plate and cover including P and F modular 6 pin 5 or 6 and 15 or 16 amps socket outlet and 15 or 16 amps switch , S and F of 5 or 6 Amp modular switch , S and F of 3 pin 5 or 6 Amp modular socket outlet , S and F of 15 or 16 Amp modular switch , S and F of 6 pin 15 or 16 Amp modular socket outlet , S and F of RJ 45 Computer Socket Cat 6 , S and F of 4 Module or 125mm x 75mm size modules GI box with base and cover plate , S and F of 8 Module or 125mm x 125mm size modules GI box with base and cover plate , S and F of 3 Module or 100mm x 75mm size modules GI box with base and cover plate , S and F of 1 or 2 Module or 75mm x 75mm size modules GI box with base and cover plate , S and D of 1 Run of UTP 4 pair CAT 6 LAN cable , S and D of 2 Run of UTP 4 pair CAT 6 LAN cable , S and D of 3 Run of UTP 4 pair CAT 6 LAN cable , S and D of 4 Run of UTP 4 pair CAT 6 LAN cable , S and D of 6 Run of UTP 4 pair CAT 6 LAN cable , S and D of 8 Run of UTP 4 pair CAT 6 LAN cable , S and D of 16 Run of UTP 4 pair CAT 6 LAN cable , S and D of 20 Run of UTP 4 pair CAT 6 LAN cable , S and M end termination with RJ45 plug , S and F modular blanking plate , S and F of 450mm heavy duty exhaust fan along with louver shutters , S and F of 225mm heavy duty exhaust fan along with louver shutters , SITC of recess mounting type 36W LED Cool White luminaire of 2 Ft x 2 Ft size modular fitting , S and installation of 22 watt LED batten, 4 feet light fitting , S and F two module stepped type electronic fan regulator on the existing modular plate switch box , ITC of ceiling Fan including wiring the down rod , SITC of 1 phase 400 mm sweep, High speed wall mounted BLDC Motor fan , SITC of Round LED down lighter recess mounting Fitting of 15W, 230 volts, 50 Hz , S and F of control contactor for emergency lighting of rating 4 Amp, having coil voltage 230 volts, 50 Hz, with 2NO plus 2NC contacts , S and L of 75mm x 38 mm size One Compartment GI raceway , S and L of coupler for 75mm x 38 mm size GI raceway , S and F of JB 150mm x 150mm x 50m mm with 50_70 mm size GI height adjustable junction box with base and cover plate , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray bend , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray TEE , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray CROSS MEMBER , S and F of 8 way 4plus24 ways Double door horizontal type TPN sheet steel MCB DB_415V , S and F of 8 way Double door vertical type 415V TPN sheet steel MCB DB suitable for mounting MCCB as incomer 8 plus 8 plus 8 ways for outgoings , S and F of 8 way Double door SPN sheet steel MCB DB_240V , P and F of 100 A 4 pole MCCB , S and F of SP 5 amps to 32 amps rating 240 V C curve MCB , S and F of SPN 5 amps to 32 amps rating 240 V C curve MCB , S and F of TP 5 amps to 32 amps rating 415 V C curve MCB , S and F of TPN 5 amps to 32 amps rating 415 V C curve MCB , S and F single pole blanking plate in the existing MCB DB , P and F 6 SWG dia GI wire along with existing surface or recessed conduit or submain wiring or cable , P and F 4 mm dia Cu bare wire along with existing surface or recessed conduit or submain wiring or cable , Supplying of 4 core 35 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable , Supplying of 3.5 core 95 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable , Laying and fixing of one number upto 35 sq. mm size cable on wall surface , Laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on wall surface , Laying and fixing of one number upto 35 sq. mm size cable on cable tray , Laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on cable tray , S and M end termination with brass compression gland and aluminium lugs for 4 x 35 sq. mm size Al cond cable , S and M end termination with brass compression gland and aluminium lugs for 3.5 x 95 sq. mm size Al cond cable , S and L of 2 x 1.5 sq mm Cu conductor armoured cable for fire alarm , S and F metal box of 75 mm x 75 mm x 60 mm deep nominal size , S and F 25 mm dia MS flexible pipe with PVC coating , ITC of Photo electric smoke detector , Dismantling of existing Fluorescent fittings _Cables_Wiring_MCB DBs , S and F of Double sided Exit sign Board with Green Super Bright LED , S and F of ISI marked ready to use CO2 type 4 point 5 Kg capacity fire extinguisher , S and L of of 1m x 2m size electrical insulation anti-skid rubber matting of 6mm thickness , Pvdg and installing of 24 port unmanaged Gigabit LAN switch 2 Layer supported , S and installing of 4U wall mounting rack for housing 24 port LAN switch , SITC of 30 Watt PDC housed LED street light fitting having IP66 protection , S and F of 3pin 5A ceiling rose on the existing junction box or wooden block , S and F of various sizes of MS boxes made out of 16 SWG MS sheet , SITC of Type_II TVSS unit as per UL 1449 standards for 3 phase 4wire plus Total Quantity :
Contract Date: Ref. Documents Contract Value : 14.99 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 10.44 Lakh
Government Departments No of Bidders 13
Maharashtra View Result →
28.
Civil Aviation #11297332 AOC
Bids Are invited for Annual Maintenance Contract of Fire Hydrant including all pumps, panels, cables, piping , Hydrants etc. , intelligent type analogue addressable Fire Alarm system and Sprinkler system including all pumps, panels, cables, piping, sprinklers etc. at Aurangabad Airport for all preventive maintenance and checks as per manufacturers manual including attending to complaints/ Faults/ break down and taking rectification action, ensuring serviceability/ satisfactory working conditions of the system, maintenance of all records, documentation etc. as per the detailed specifications, terms & conditions covered under this contract on all days including sundays and holidays as per requirements of AAI. , Annual maintenance contract of Kirloskar make DG pump set (with specification mentioned under (A)) i/c engine control panel and other accessories of DG pump set.Job includes monthly visits for carrying out preventive maintenance, attending any number of breakdown calls when required, carrying out B and C check, minor repairs etc. as per manufacturers recommendations / standard practice and as per the scope of work, complete as required. A) Engine type - 6R1080, Rating - 79 hp, RPM - 1500, governing class - M2. , Supplying, installation, testing & commissioning of Conventional Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of addressable Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required. (Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of Conventional Multi Sensor detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) , Supplying, installation, testing & commissioning of conventional manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc.complying to relevant IS etc. as required.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complying to relevant IS etc. as required. (Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional fire alarm panel , 16 X 2 dotmatrix LCD display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189, complying relevant national fire alarm code for local fire alarm system with mimic diagram for allarea/zone covered, complete with all connections. The panel shall have input of 240 volts AC power supply, automatic battery charger, 24 volts, 2 X 12 volts, 12 Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL listed & FM approved and shall be hookup with PA system and along with auto dialer facility etc. as required. (Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions along with battery stand as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS etc. as per specification, complete as required.(Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.(Approved Makes : CMI/ KEI/ BONTON/ POLYCAB/BATRA HENLAY/ RR CABLE/ WAREXHAM). , Supply of 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with necessary male and female gun metal / SS couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , Supply of standard short sized branch pipe constructed from SS material of 63mm dia.and be complete with male instantaneous spring lock type coupling for connection to the end of hose pipe,Externally threaded to receive nozzle,conforming to IS:903 etc. complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , supply of nozzle,20mm inner diamter,made of SS,screw threads at the inlet connection to match with the threading of 63mm dia branch pipe with inlet end of hexagonal head to facilitate screwing conforming to IS 903 etc. as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).
Contract Date: Ref. Documents Contract Value : 13.35 Lakh
Boards / Undertakings / PSU No of Bidders 11
Daman and Diu View Result →
29.
Educational and Research Institute #11294681 Technical Bid
Tender for Purchase Of Trainer Kits And Function Generator , Trainer Kits And Function Generator , Function Generator Frequency Range : 0.11 Hz To 3.33 Mhz Waveforms: Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Duty Cycle Control And Variable Dc Offset Control -20Db * 2 And Variable Attenuator. Waveform Types Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Ttl Output Range 4Vpp - 20Vpp 4.8Vpp Sine Wave Distortion 0.11 Hz-100: Max 0.5 % 0.1 Mhz - 0.3 Mhz Max 1.5% 0.3 Mhz - 3Mhz Max 3% Square Wave Rise /Fall Time Overshoot Duty Cycle ≤ 60Ns ≤ 7.5% 50% Pulse Wave Pulsewidth Range Rise /Fall Time 15 % To 85 % ≤ 60Ns Ttl Output Level Amplitude Fan-Out Rise /Fall Time ≥4.8Vpp 10Ttl Load ≤ 60Ns The Display Shows Function And Frequency On The 16*2 Lcd Display Amplitude We Get From 1.5 V Pp To 20 V Pp And Varies As Per The Different Frequency Range Amplitude Distortion Without Load Wave 1 Mhz 2Mhz Sin 20 Vpp 18 Vpp Square 20 Vpp 20 Vpp Triangle 20 Vpp 16 Vpp Pulses 20 Vpp 18 Vpp Ttl 5 Vpp 5 Vpp Dc Varies From 0 ± 5V Dc Function Generator Frequency Range : 0.11 Hz To 3.33 Mhz Waveforms: Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Duty Cycle Control And Variable Dc Offset Control -20Db * 2 And Variable Attenuator. Waveform Types Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Ttl Output Range 4Vpp - 20Vpp 4.8Vpp Sine Wave Distortion 0.11 Hz-100: Max 0.5 % 0.1 Mhz - 0.3 Mhz Max 1.5% 0.3 Mhz - 3Mhz Max 3% Square Wave Rise /Fall Time Overshoot Duty Cycle ≤ 60Ns ≤ 7.5% 50% Pulse Wave Pulsewidth Range Rise /Fall Time 15 % To 85 % ≤ 60Ns Ttl Output Level Amplitude Fan-Out Rise /Fall Time ≥4.8Vpp 10Ttl Load ≤ 60Ns The Display Shows Function And Frequency On The 16*2 Lcd Display Amplitude We Get From 1.5 V Pp To 20 V Pp And Varies As Per The Different Frequency Range Amplitude Distortion Without Load Wave 1 Mhz 2Mhz Sin 20 Vpp 18 Vpp Square 20 Vpp 20 Vpp Triangle 20 Vpp 16 Vpp Pulses 20 Vpp 18 Vpp Ttl 5 Vpp 5 Vpp Dc Varies From 0 ± 5V Dc 1. Equipped With 16 High-Visibility Leds For Monitoring Experimental Outputs And Logic Status Indication. 2. Dedicated Driver Circuitry Provided For Reliable Operation And Protection Of All 16 Leds During Experimentation. 3. All 16 Driver Input Lines Are Terminated Through Banana Connectors For Flexible And Easy External Interfacing. 4. Includes 16 Spdt Toggle Switches For Generating Manual Logic Input Conditions In Digital Electronics Experiments. 5. Additional 16 Leds Provided To Display The Real-Time Status Of Individual Switch Operations. 6. One Terminal Of Each Spdt Switch Is Externally Accessible Through Banana Sockets For Convenient Circuit Connections. 7. Built-In Variable Clock Generator Enables Pulse Generation For Sequential And Timing-Based 8. Digital Experiments. 9. Frequency Adjustment Provided Through Potentiometer And Rotary Switch Combination For Precise Clock Selection. 10. Clock Output Is Terminated Through Banana Connectors For Quick Integration With External Circuits And Trainer Modules. 11. Features Dual 7-Segment Led Display With 7447 Decoder/Driver Ic For Bcd To Display 12. Conversion Experiments. 13. Inputs Of The 7447 Drivers Are Terminated At Banana Connectors For Direct Digital Logic Interfacing. 14. Includes Solderless Breadboard For Rapid Circuit Prototyping And Reusable Experimental Setup Development. , Strain Gauge Study Trainer This Trainer Shall Consists Of Cantilever Jig And Strain Gauge Bonded On The Cantilever, A Signal Conditioner For The Strain Gauge, Instrumentation Power Supply, 3½ Digit Digital Indicator Display The Strain. * Cantilever Beam Of Maximum Weight Upto 1Kg. * A Pan With Slotted Weights To Vary The Strain. * Built In Instrumentation Power Supply * Signal Conditioning Card For The Strain Gauge * 3½ Digit Digital Display For Displaying The Strain * Offset And Gain Variable Provision * Logical Diagram With Panel. * Mounted In Sleek Cabinet. 1) On Board Carrier And Modulating Signal Generator With Amplitude And Frequency Adjustable 2) Carrier And Modulating Signals Are Provided In The Unit With Frequency Variable. 3) In-Built Regulated Power Supply 4) On Board Envelope Detector 5) Schematic Diagram Provided In The Front Panel Modulating Signal Frequency : (300Hz-3 Khz) Amplitude : (0-5) V Carrier Signal Carrier Signal Frequency : 10 Khz - 50 Khz Amplitude : (0-15) V Type Of Modulator : 1. Ring Modulator 2. Transistor Based Modulator Method Of Modulation : 1. Under Modulation 2. Critical Modulation 3. Over Modulation , Load Cell Study Trainer This Module Shall Consists Of A 5Kg Load Cell Sensor, Weights, Signal Conditioner And 3½ Digit Digital Indicators To Display The Load. * Strain Gauge Based Load Cell Sensor Of 5Kg Capacity * A Pan Provision For Placing The Standard Weights Signal Conditioner For Load Cell (Output 0-5V) * Built In Instrumentation Power Supply * Zero Calibration Provision. * 3½ Digit Digital Indicator To Display The Applied Load. * Mounted In A Elegant Powder Coated Cabinet With Mimic Diagram 1) On Board Sine Wave Generator 2) Provision To Study Modulation & Demodulation In The Same Unit 3) Test Points To Study Different Waveforms 4) In-Built Audio Power Amplifier 5) Mic Pre Amplifier 6) Built-In Power Supply 7) Sine Wave Generator : Frequency - 100Hz To 1.2 Khz With Amplitude Adjustable, (0-5V) 8) Fm Modulator : Direct Fm 9) Carrier Frequency : 20 Khz (Low), 367 Khz(High) 10) Fm Demodulator : Pll Detector, Quadrature Detector, Foster Seelay Discriminator / Phase Discriminator, Ratio Detector Are Provided. 11) Audio Power Amplifier : Gain 100 12) Mic Pre Amplifier : Gain 20 , Lvdt Study Trainer It Shall Consists Of A Lvdt Sensor, Signal Conditioner And A Digital Indicator To Display The Displacement Cantilever Jig With Micrometer. * Lvdt Sensor With Micrometer (Range: 0-25Mm) * Signal Conditioner For Lvdt * Displacement Calibrated Range From (-10Mm To + 10Mm) * Output Voltage (-5V To +5V) * Built In Instrumentation Power Supply * A 3½ Digit Digital Indicator To Display The Displacement * Mounted In A Elegant Powder Coated Cabinet. * Logical Diagram In The Panel Detailed Documentation , Thermistor Study Trainer  One Negative Temperature Co- Efficient Type Thermistor Sensor Is Used As A Temperature Sensor.  Signal Conditioner For Thermistor Transducer: Output 5-0V  Built In Instrumentation Power Supply  A 3½ Digit Digital Indicator Is Used For Voltage Display  Zero Calibration Provision  Water Bath Is Used As A Heat Source.  Thermometer Is Provided To Monitor The Actual Temperature.  Mounted In An Elegant Cabinet , Thermo Couple Study Trainer * One J Type Thermocouple Is Used As A Temperature Sensor * One Ad590 Sensor Is Used For Cold Junction Compensation * Signal Conditioner For J Type Thermocouple Output: (0-5V) * Built In Instrumentation Power Supply * 3½ Digit Digital Indicator To Display The Temperature. * Water Bath Is Used As A Heat Source * Zero Calibration Provision * Thermometer Provided To Monitor The Temperature * Mounted In A Elegant Powder Coated Cabinet * Logical Diagram In The Panel Detailed Documentation , Rtd Study Trainer * Pt100 Type Rtd Is Used As A Temperature Sensor * 3 Wire Configurations Is Provided Signal Conditioner For Rtd Output Is (0-5V) * Built-In Instrumentation Power Supply * A 3½ Digit Digital Indicator To Display The Temperature * Water Bath Is Used As A Heat Source. * Thermometer Provided To Monitor The Actual Temperature * Mounted In A Closed Cabinet. Detailed Documentation. , Piezo Electric Transducer Study Trainer This Trainer System Shall Consists Of Vibration / Acceleration Sensor Of Piezo Electric Type, Signal Conditioner, Regulated Power Supply, 3½ Digit Digital Indicator Etc Provided To Study The Characteristics Of Piezo Electric Sensor * Vibration Sensor Of Piezo Electric Type Mounted In The Base Plate To Sense The Vibration Of The Material. * Precision Rectifier Circuit For Above Sensor. * Signal Conditioner Of (0-10)Vdc * Ic Regulated Power Supply * 3½ Digit Digital Indicator To Display The Voltage. * Logical Diagram In The Panel * Mounted In A Powder Coated Closed Cabinet. Vibrator Exciter  One Mechanical Setup Provided  One Vibration Motor To Vibrate The Mechanical Setup # I/P : 230V Ac/50 Hz # Power : Max: 0.5 Hp One Auto Transformer Is To Vary The Input Voltage For Mechanical Setup , Schrings Bridge * 4 Arms With Suitable Connectors. * Provision To Connect The Unknown Capacitance At One Arm * Two Potentiometers Provided At Two Arms To Obtain The Bridge Balance Condition. * Input Of The Bridge Is Taken From A 1Khz Fixed Amplitude Oscillator. * One Audio Amplifier With Miniature Speaker Is Provided To Detect The Bridge Balance Condition Acoustically. * Measuring Range : 0.001Uf - 2.0Uf * Sensitivity : +0.1Uf * Tolerance : +5% * All Are Housed In A Metal Cabinet * Detailed Documentation * Required Patch Chords Are Provided Decade Capacitance Box Dial 1 :0-0.01Mfd In Steps Of 0.001Mfd Dial 2 :0-0.1Mfd In Steps Of 0.01Mfd Dial 3 :0-1Mfd In Steps Of 0.1Mfd Dial 4 :10Mfd In Steps Of 1Mfd Total Range : 0-11.11Mfd , Maxwells Inductance Bridge * Four Arms Are Provided With Suitable Connectors * One Arm With Provisions To Detect The Nearest Range Of Unknown Inductance. * Two Arms With Variable Potentiometers Given To Balance The Bridge In Null Condition * One 1 Khz Oscillator Of Fixed Amplitude To Feed The Input To The Bridge. * One Audio Amplifier With Speaker To Detect The Bridge Balancing Conditions. * Measurement Range: 15Mh - 200Mh * Tolerance : +5% * Built-In Power Supply * Connector Facility Given To View The Output Of The Bridge Externally By Cro * All Are Housed In A Powder-Coated Cabinet With Logical Diagram. * Required Patch Chords Are Provided Decade Inductance Box Dial 1 :0-9Mh In Steps Of 1Mh Dial 2 :0-90Mh In Steps Of 10Mh Dial 3 :0-900Mh In Steps Of 100Mh Total Range :0-999Mh , Voltmeter Desk Top Analog Voltmeter (0-1V Dc, 0-10V Dc, 0-30V Dc, 0-5V Dc) Each 5 Nos , Ammeter Desk Top Analog Ammeter (0-10Ma Dc, 0- 50Ma Dc, 0-100Ma Dc, 0-500Microa Dc) Each 5 Nos , Digital Trainer Kit * 16 LedS Are Provided To Indicate The Status/Outputs Of An Experiment. * Drivers Provided To Drive The 16 LedS * All The 16 Inputs Of The Driver Are Terminated At Banana Termination For Easy Wiring Of Any Experimental Setup. Input Switches : * 16 Spdt Switches As Logical Inputs Are Provided. * 16 LedS Provided To Display The Status Of The Switches. One End Of Each Spdt Switch Is Terminated At A Banana Termination For Easy Wiring. , Ic Tester It Is The Latest Microcontroller Based Universal Ic Tester. It Functionally Tests A Wide Variety Of Analog/Linear Ics Including Adc,Dac,Dpm Ics, Op Amps, Transistor Arrays, Waveform Generators And Digital Ics Including Microprocessors, Microcontrollers, Eproms, Rams, Peripheral Devices Apart From 74 Series Of Ttl Ics And 40/45 Series Of Cmos Ics
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
30.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2.12 Lakh
Boards / Undertakings / PSU No of Bidders 5
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 84,000
Government Departments No of Bidders 14
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 63,000
Boards / Undertakings / PSU No of Bidders 4
Contract Date: Ref. Documents Contract Value : 1.84 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Contract Date: Ref. Documents Contract Value : 3.35 Lakh
Boards / Undertakings / PSU No of Bidders 11
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 35.64 Lakh
Government Departments No of Bidders 5
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 4.84 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 8,436
Statutory Bodies & Commissions/Committees No of Bidders 5
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 1.52 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 6.90 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
44.
Banking and Finance #11236945 AOC
Bids Are invited for Loss Prevention Active And Passive Fire Protection Systems Fire Door - Providing, Fixing, Testing And Commissioning Of Two Hour Fire-Rated Single/Double Panel Door & Door Frame According To Approved Design & Shop Drawing Door Frame Made Using 1.2 Mm Thick Galvanized Steel Sheet Conforming Is 277 For Formed To Single Rebate Profile Of Size 100Mmx50mm & With Maximum Bending Radius Of 1.4 Mm. Door Frame With Mitred Joints To Have 40Mm Width All Around The Lobby Side. Frame To Be Provided With Back Plate Bracket For Installation Using Anchors. The Frame To Be Fixed Using 8Mm Expansion Anchors (Hilti/Equivalent) As Per Approved Design. Rate To Also Include Providing, Erecting & Fixing Single/Double Leaf Minimum 44Mm Thick Metal Finish Door Shutter Constructed From 0.8Mm Thick Galvanized Steel (Gpsp) Sheet Conforming Is 277, Fully Flush, Double Skin Door Shell With Lock Seam Joints And Stile Edges, Internal Reinforcements Provided At Top, Bottom & Stile Edges For Fire Rating. The Internal Construction Of The Door Should Be A Resin-Bonded Specially Designed Honeycomb Structure With Reinforcements At Top, Bottom & Stile Surrounds. Doors Shall Be Factory Prepped For Receiving Specified Hardware. Vision Panel, Where Specified, Shall Be 6Mm Thick Clear 2 Hour Fire Rated Glass. The Door Assembly Shall Be Fire Rated For 120 Minutes , A - Double Door , B - Single Door , Fire Rated Paint - Fire Rated Paints For All Partition Wall Are Specialized Intumescent Coating That Swell When Exposed To High Heat, Forming A Thick, Char-Like Barrier For 30 To Over 120 Minutes. Ensure The Paint Complies With Local Fire Safety Codes, Such As Bs 476, Din En 13501,Or Astm. Varies By Product With Some Providing 10-12 Sq.M/Ltr. , Fire Suppression System - Supplying, Installation, Testing And Commissioning Of 58.5Kg Cylinder/Valve Assembly. , B - Supplying, Installation, Testing And Commissioning Of Novec 1230 - Agent Filled In The Above Cylinder. , C - Supplying, Installation, Testing And Commissioning Of Master Valve With Automatic Cum Manual Actuator, Including Trim Complete With All Accessories. , D - Supplying, Installation, Testing And Commissioning Of Slave Valve With Actuator, Including Trim Complete With All Accessories. , E - Supplying, Installation, Testing And Commissioning Of Actuation Hose , F - Supplying, Installation, Testing And Commissioning Of Discharge Hose , G - Supplying, Installation, Testing And Commissioning Of Nrv , H - Supplying, Installation, Testing And Commissioning Of 58.5 Kg Cylinder Strap. , I - Supplying, Installation, Testing And Commissioning Of Nozzles , J - Supplying, Installation, Testing And Commissioning Of Warning Sign Stickers. , K - Supplying, Installation, Testing And Commissioning Of Astm Schedule 40(Seamless Pipe) (A106 Grade B) , K I - I) 25Mm (6.2 Mm) , K Ii - Ii) 32Mm (Header) (8 Mm Minimum) , Fire Alarm And Detectors - Supply, Installation, Testing & Commissioning Of 1 Zone Gas Release Panel (Control Panel) , B - Supply, Installation, Testing & Commissioning Of Smoke Detector , C - Supply, Installation, Testing & Commissioning Of Abort Switch. , D - Supply, Installation, Testing & Commissioning Of Manula Call Points. , E - Supply, Installation, Testing & Commissioning Of Electronic Strobe With Hooter. , F - Supply And Laying Of Frls Armoured Cable 2Cx1.5 Sqmm , Portable Fire Extinguishers - Supply And Installing Isi Marked As Per 15683 Fire Extinguisher, Carbon-Di-Oxide Type Capacity 4.5 Kgs Complete In All Respect. , B - Supply And Installing Abc (Powder Type) Fire Extinguisher Mild Steel Cylinders Isi Complete Confirming To Is 15683. , C - 6 Kgs. , D - 2 Kgs. , E - Supply, Installation, Testing And Commissioning Of Exit Sinage Of Photo Luminescent On Aluminium Sheet Of 1.0 Mm Containing Lumigen-Iii As Base Chemical, Covered With Uv Stabilized Coating Size 450 X 200. Total Quantity : 1003
Contract Date: Ref. Documents Contract Value : 8.71 Lakh
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 80,000
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 89,000
Government Departments No of Bidders 3
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Himachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 4.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
49.
Defence #11213485 AOC
Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon.; 1 Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering all as specified and directed. 2 Dismantling timber in fillets rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work 3 S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 4 S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Eaves boards, fixed with self tapping screws as specified 5 S & F Rolled Mild Steelroof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete. 6 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering.doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening andfixing complete (Eaves board fixing ) 7 S & F 6mm thick asbestos cement plain building boards fixed to steel frameowrk with screws all as specified and directed ( For Eaves Board). 8 S &F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-w (Gde E-250 quality A) all as specified and directed. 9 M & L for Preparation of newsteel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paintover red oxide primer for material and labour complete all as specified. 10 M & LPCC B1 1:2:4 (12.5mm graded aggregate) for in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. (Note :- Bed boxes and Coping on wall to fill up the gap) 11 Demolition of Brickwork or stone/boulder masonry/PCC bloack masanory,built in cement motar all as specified and directed. 12 S & F brick work with fly ash bricks,straight or cuved on plan exc 6m mean radius built in CM 1:4all as specified and directed. (Note : 1. For filling the Gap between sheet and wall 2. Clsoing of ventilaots ) 13 Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge 14 Material and labour for suspended false ceiling usinganodized aluminum snap grid frame work.Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete. Perforated particle board/tiles for insulation and acoustic purposes, 60 x 60 cm size, fixed on snap grid 12mm thick confirming to IS 2095, 2995 Part I fixed with 25mm dry wall screws @ 230 mm C/C with screw driver to match surface attachment. Finally board have to be joined and finished to have a flush look using jointing compound/tape as per manufacturer instruction. With Designing as per direction in two steps complete all as specified and directed by Engineer in Charge. 15 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:4and is to be finished even and smooth with out using extra cement complete all asspecified directed 16 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 17 M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed. 18 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out hard dense soil 19 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting poin 20 Hard coare of broken stone aggregate, of gauge n.exc 60 mm 21 M&L for cement concrete Type D -2 1:4:8 (40 mm graded agg) in foundation fillig/path and mass concrete 22 Formwork to sides of flat concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter 23 M&L Forming Contraction (Dummy) joints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade A in plinth protection 24 Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) 25 S &F 605 x 605 mm Anodised aluminium snap grid frame work for false ceiling all as specified 26 Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified 27 Dismantling boarding, any description, fixed in any position with nail 28 Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete 29 M&L rendering 15mm thick on surface of concrete surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 30 Demolition of stone / block masonry built in CM 1:4 31 M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) and set in CM (1:6). 32 Preparing new wall surface, providing and applyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of oil emulsion 33 Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners withholdfasts and brackets, complete 34 S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 35 S&F Sheet glass 5.5 mm thick ordinary quality and glazing fixedin aluminium doors squareexc 0.5 sq. m in each pane 36 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers 37 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 38 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats 39 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) 40 M & L for 100mm thick PCC type B-2 (1:2:4) using 40mm graded aggbnas in flooring finshed even and smooth w/o using extra cement. 41 M & L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded agg finished even and smooth w/o using extr cement. 42 M & L for nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectamgular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors (Superior/ Premium quality), set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15mm thick screed bed in CM (1:6) complete all specified and directed. 43 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in Charge. 44 M & L fire resistant paint on steel surface over a coat of primer complete alll as specified (Note: The primer is of same material of 1:1 dilution application) 45 S & F of mineral fibre reinforced false ceiling tiles (all height)of size 595X595 mm of approved texture, design and pattern. The tiles should have humidity risistance RH of 99%, Light resistance greater than 85% , thermal conductivity K=0.052-0.057 W/mK, Fire performnce As per (BS476 Pt-6&7) in true horizontallevel suspended on interlocking T-grid of hot dipped all around ganvanisedIron Section of 0.33mm thick (galvanised @ 120GSM)bcomprising of main T runner of 15 X32 mm of length 3000mm, cross T of size 15X32 mm of length 600mm to form grid module of size 600X600 mm suspended from ceiling using galvanised Mild steel item ( galvanised @ 80GSM) 50mm long 8mm outer dia M-6 Dash Fastner, 6mm diameter fully threaded hanger rod upto 1000mm length and L-shped level adjuster of size 85X25X2mm, spaced at 1200 mm center to center along main T, the system should rest on perpfery walls/ partition with the help of GI perimeter wall angle of size 24X24X300mm made of 0.40mm thick sheet, to be fixed to the wall with the help of the plastic rawl plug at 450mm center to center & 40mm long drywall S.S screws. The exposed bottom portion of all y- Sectionused in false ceiling support system shall be prepainted with polyster baked paints, for sll heigth. the work shall be carried outas per specification drawing adn as per the direction of the Engr-in-charge with 16mm thick Bevelled traingular Mineral Fibre faalse ceiling (NRC 0.5 to 0.6)) 46 Taking down and of chowkats or frames exc 1.5 sqm n exc 4 sqm each 47 S & F Anodised aluminium frame powder coated to (minimun thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 48 S & F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,ruber neoprene packing, handk=les 2 Nos in each door, hinges, anodises aluminium snap beading screws etc. complete all as specified. 49 Cuting holes exc 150 sqcm but not exc 400 Sqcm into or through brick walls built in cement mortar of any description and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-I as required 50 m&L two coats or Oil Bound distemper on Cement concrete surface over a coat of primer as per the shed directed by the engineer-ncharge, complete all as specified. 51 M&L for treating small articles such as ends of posts, holdfasts etc with tar or coal tar black paint; area exc 0.1 Sqm but n exc 0.5 Sqm each 52 S&F sheet in repairs glass 4.8 mm thick exc 0.5 sqm area ordinary quality and glazing with oil putty/rubber gasket fittings all as specified and directed. 53 M & L in repairs for 12mm Prelaminated particle board, interior grade, prilaminated both side with decorative choice lamination fixed with screws to timber/Aluminium frame work complete all as specified and directed. 54 S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I 55 S & F in repairs 20 mmBrass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed 56 S&Fbib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap). 57 S&F GI tubingof 15 mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 58 S&F GI tubingof 20mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 59 S&F GI tubingof 25mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 60 S&F25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 61 S&F20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 62 Dismantling wrought iron or mild steel work of any description not otherwise provided for. 63 S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 all as specified and directed.(Eaves Baords) 64 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 65 Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed 66 M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified 67 M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified 68 M&L for reinforced cement concrete M 20 using 20mm crushed stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. 69 M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. 70 M&L for preperation of new concrete /plastered surface of any description, two coat of plastic emulsion paint over a coat of primer complete all as specified and as directed complete all as specified and as directed. 71 M&L for Powder Coated (Minimum thickness of powdercoating 50 micron)Anodised aluminium frame of standerd section for doors, windows, ventilators and partitions withdoublerebates including joining cleat for fixing etc. complete all as specified 72 S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (For sliding window ) 73 M&L sheet glass 4.0mm thick figured glass, pin head type and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed 74 M&L for vetrified ceramic tiles 10mm thick full body(Dark shade/Ultra Charged/Double charged ) (square/rectangular) polished, area of each tilesexc 1.00 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 75 M&L for vetrified ceramic tiles 10mm thick full body(lightshade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 76 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediatechannel at 457 mm centre to centre and including Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified 77 S&F for 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish(Frame work for ceiling shall be measured and paid separately) 78 Removal of existing Rifle racks including all fixing stell bolts and cement work all as specified work 79 M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified 80 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 81 M & L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. 82 M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 83 M&L for machine cut mirror polish kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 84 Fixing and grouting of new steel Rifle racks on the floor including necessary fixing bolts and necessary arrangements of grouting and grouting material all as specified. 85 M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 86 S&F for Mild steel ,plain black sheet of minimum 0.8mm thickness for Hoods cover for Rolling shutters;cladding to door shutters/Hangar doors ; water tank platforms etc with plain 40mm lap joints or welded/riveted seams including ,bending, turning up, mitred angles , stopped ends,outlets,etc. as required all as sprcified and directed by Engr-in Charge. 87 M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. 88 Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. including sorting out serviceable and unserviceable light fitting and keep serviceable fitting in safe guard for reuse as required on site. 89 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 90 Taking down cearfully byunscrewingthe unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts etc all as directed. 91 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and capingwith all fittings/fixture etc andsurface typePVC box, cover plate all as specified and directed by Engr-In-Charge.(a) Onelight point controlled by one switch. 92 (b) One 3 pin socket 5 A on independent board. 93 (c) One 3 pin socket 5 A on same board. 94 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,with all fittings/fixture etc andsurface typeModular , PVC box cover plate, frame all as specified and ndirected by Engr-In-Charge. 95 S & F Sub Main Wiringwith FRLS PVC Insulatedmultistranded copper conductorwires ofsize2x6.0 sq. mm + 1x6.0 sq. mm earth wire in casing caping complete as directed.Note : for Item No 95 One run of phase wire one run of Neutral wire and one run of Earth wireand one run of casing and capping shall be meassured and as one length. 96 S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps.including fixing concealed in wall and making good the disturbed surfacecomplete all as directed 97 Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 98 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed 99 S&F MCB SP 240 volt 6 to 32 A C series complete 100 S &F for MCB SPN 40-63 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. 101 Supply and fix Modular switch 1 way 6A, 1 module 102 Supply and fixmodular Socket, 6A - 2/3 pin combined 2 moduler 103 Supply and fixModular switch 1 way 16A, 1 module 104 Supply and fixmodolar Socket 6A/16A - 2/3 pin combined2 module, 105 Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm 106 S & F Modular white cover plate with frame 2 Module 107 S & F Modular white cover plate with frame 3 Module 108 S & F Modular white cover plate with frame4 Module 109 S & F Modular white cover plate with frame 6 Module 110 S & F Modular white cover plate with frame 8 Module 111 Supply, Fixing , Testing and Commissioning of Single phase isolation transformer to be installed at input power supply of L-2 switch,via 16 Amps MCB and with power earthing point specification as follows 1Ph, Capacity 1KVA, Input 230V AC ±10%,Output 230V±10%,50 Hz,cooper wire,work efficiency more than 95%,potential between earth to neutral less than 1 Volt with all standard fitting as per direction of Engineer in charge 112 Supply, Fixing , Testing and Commissioning ofIsolation transformer of capacity 5 KVA, single phase ,50 Hz , Copper wound , Air cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 240+-5% and output voltage range 240+-5% ,Ratio 1:1 , indoor , efficiency more than 95 % , Potential difference between neutral to earth less than one volt with all standard fittingsas per direction of Engineer in charge 113 Supply, Fixing , Testing and Commissioningof Three Phase Surge Protector Device to be installed at input power supply of L-2 switch all as specified and directed by Engr-In-Charge 114 S&F wall mounted Industrial grade metal enclosure box made from 3mm thick CRCA sheet consist of following Items:-(a) Panel mounting Industrial grade socket/plug outlet 16 A,IP44(b) SPD ,1.5kv,320A,20kA - 1 Nos(c ) MCB SP 16 A- 1 Nos 115 S&F Vertical double door Distribution board TPN 4 way 125 A rated busbarconsisting ofMCCB. 63 A 18KA - 1 Noincluding fixing on wallsurface and making good the disturbed surfacemaking all nacessary incomming and out going connections using proper size copper thimblescompleteall as required on site all as directed 116 Supply and fixing in replacement sheet metal enclosure with DBs ( grouted in walls) double door type for MCBs 12 ways with 200 Amps 240 volts rated bus bar incl taking down old DB all as specified. 117 Material and labour for taking down serviceable Fire Alarm panel from one location and re-install the same at same /another location including fixing brackets/nut bolts incl testing and commessioning of the same all as specified and directed 118 Material and labour for taking down serviceable Smoke / Heat / Fire detector from one location and re-install the same at same /another location including necessery cable upto Fire alarm panelincl testing and commessioning of the same all as specified and directed 119 Supply and fix adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 all as specified. 120 Supply, install, testing and comissioning of adessable break glass manual call pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. 121 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade. 122 Material and labour for taking down serviceable split AC of capaicty upto 2.0 TR from one location and re-install the same at same /another another location including fixing brackets, gas charging, brazing and additional required copper piping incl testing and commessioning of the same all as specified and directed 123 Supply, Install testing and commessioning Single pole and neutral enclosure 240 Volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed 124 Material and labour for providing point wiring with two runs of 4 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,ISI Marked complet for housing one 15 to 20 A Switch / socketscomplete 125 Supply, Install , Testing and Commissioning of wall mounted enclosure box made from 3mm thick CRCA sheet enclosure consist of following items for 3 Phase 2 AC timer & Controller of Auto switching timer unit suitable for operate 8.75 TR package type AC:-(a) Timer - 1 No(b) Contactor 32 amps - 2 No(c ) Indication lamp - 1 No
Contract Date: Jan 09, 2026 Contract Value : 44.46 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 3.89 Lakh
Government Departments No of Bidders 4
TenderDetail
Loading tenders