View Bid Results For Megger Tenders

We found 1262 Bid Results related to megger tenders. You can find Contractor details who won megger tenders along with contract details in Bid awards announcements section.

Filters
Stage
1063
126
73
Tender Publishing Platform
546
716
State / UT
37
157
122
111
95
81
79
76
69
55
51
45
41
37
34
34
27
24
24
20
17
15
11
6
6
4
3
3
2
2
2
2
2
1
1
1
1
1
Contract Value
402
480
328
48
Publish Date
3
0
0
0
0
Sector
26
305
221
203
122
120
60
45
28
24
22
19
18
14
11
11
10
10
5
5
3
1
1
1
1
1
1
Ownership
7
832
203
153
52
16
3
3
Within keyword
Active filters:
Showing 1–26 of 1262 tenders matching your filters
6.
Railways #11358092 AOC
Supply Of angle grinders , supply of analog earth tester; metal body with four spikes testing kit; conforming to is-9223- 1986;range 0 to 100 mohms; hand driven generator type with test & warranty certificate. make: shanti/w aco/cie/megger. [ warranty period: 30 months after the date of delivery ] ] , cordless small angle grinders, power 220-240v ac, 50/60 hz, specification battery voltage 2 0 v no load speed 6600 rpm rated input power 1000 watt power supply 220-240v ac, 50/60 hz disc dia meter 150 millimeter tool type cordless batteries included yes warranty 1 year. [ warranty period: 30 months after the date of delivery ] ] , angle portable hand grinder suitable for 230 v ac 50 hz [ warranty period: 30 m onths after the date of delivery ] ] , 5-angle grinder specification:no load speed 10500 rpm spindle thread size 3/8 inch - 16 r ated input power 670 watt power supply 220-240v ac, 50/60 hz noise level 65 decibel disc diameter 100 millimeter grinding spindle thread m10 tool type corded item small angle grinder height 12 centimeter l ength 30 centimeter width 9.2 centimeter weight 1.72 kilogram [ warranty period: 60 months after the date of delivery ] ] , small angle grinder as per specification attached. [ warranty period: 30 months after the d ate of delivery ] ] , rotary hammer drill machine with drill bit 30 cm is designed for punching ofholes in har d material through the use of firing machnism working on single phase 230 v ac 50 hz supply [ warranty period: 30 months after the date of delivery ] ] , light weight heavy duty electric portable drill machine having capacity 6 mm di a in ms sheet and compreg sheet, with input power 350-500 w rated voltage - 110 v input (ful l load),no load rpm in between 0-3400 rpm with veriable speed, drill torque 3.5 nm nature o f supply 110 v, 50 hz, total weight 1.5 kgs. (minimum) body of the machine should be made of high strength polymide (nylon-66) with 150 kilojules per sq. mtrs. with auto cut-off carbon brush and spare one set carbon brush one set of chuck and key with each set of machine to is: 4665/1984 of bosch/hitachi/fein/milwakee make preferably. [ warranty period: 30 months afte r the date of delivery ] ] , angle grinder gws 800 watt ,100 mmdisc [ warranty period: 30 months after the date of delivery ] ] , angle grinder gws 800 watt ,100 mmdisc [ warranty period: 30 months after the date of delivery ] ] , angle grinder gws 800 watt ,100 mmdisc [ warranty period: 30 months after the date of delivery ] ] , corded brushless electric drill 600watt, power supply- 220-240 v, 50hz +/- 10, power rating - 600 watt, maximum speed (rpm) 2600 rpm (variable speed), make:- bosch, dewalt, tiger, velmoc, msi, stanley, foster, hitachi. [ warranty period: 30 months after the date of delivery ] ] , portable hand grinder as per specification attached. [ warranty period: 30 months aft er the date of delivery ] ] , electric hand tool kit includes drill machine, drill bits,hammer, screw spanner,measuring ta pe,various types of screw bits,pliers,screw drivers as image attached, [ warranty period: 30 months after the date of delivery ] ]
Contract Date: Jun 25, 2026 Contract Value : 2.15 Lakh
Government Departments No of Bidders 1
9.
Educational and Research Institute #11330304 AOC
Supply Of Electrical Items For Repairs Of Core Block Wards, Nims, Punjagutta-500.00 35Mm Screws 1000.00 Chromium Plated Saddles With Base 500.00 25Mm Pvc Junction Boxes Normal. 500.00 25Mm Dia 1.5Mm Thick Pvc Bends. 500.00 25Mm Pvc Pipe. 3000.00 U Nails. 120.00 Fan Hook 400.00 25Mm Casing And Caping. 80.00 3 Module Box. 60.00 6 Module Box. 150.00 9 Module Box 220.00 12 Module Box 80.00 3 Modular Cover Frame. 60.00 6 Modular Cover Frame. 150.00 9 Modular Cover Frame. 220.00 12 Modular Cover Frame. 500.00 3 Plate Jumbo Ceiling Rose. 1100.00 6A / 10A 1 Way Modular Switch. 700.00 6A Modular Socket 600.00 16A / 20A 1 Way 1 Module Switch. 600.00 16A / 6A Socket Modular Socket 80.00 Dp / Tp / Fp Metal Enclosure 80.00 6-32A 10Ka Dp Mcb 7000.00 22 / 0.3Mm ( 1.5 Sqmm ) Frls 4000.00 36 / 0.3Mm ( 2.5 Sqmm ) Frls 6000.00 56 / 0.3Mm ( 4.0 Sqmm ) Frls 1500.00 84 / 0.3Mm ( 6.0 Sqmm ) Frls 1000.00 140 / 0.3Mm ( 10.0 Sqmm ) Pvc Frls 20.00 4 Way Tpn Db 20.00 63A Fp Isolator . 200.00 6-32A 10Ka Sp Mcb 20.00 Gi Earthing 10.00 Copper Earthing 400.00 G.I. Strip / Plate / Wire ( Per K. G ) . 100.00 Copper Plate / Copper Strip ( Per K.G ) . 20.00 23 / 0060 Twin Core Twisted 60.00 No.8 Screws Of 35 / 38Mm. 200.00 Rawl Plugs. 0.00 22W Led Light 20.00 36W , 2 X 2 ( 600Mm X 600Mm ) Led 60.00 Bh / Sbh 60.00 5 W Led Lamp 60.00 48 ( 1200Mm ) Ceiling Fan 10.00 Geysor 25 Ltrs 120.00 19 / 20Mm Steel Tube Down Rod 20.00 12 ( 300Mm ) Isi, 900 Rpm Exhaust Fan 20.00 Louver Shutter Including Gi Mesh 10.00 2 Pair, 0.5Mm Telephone 1500.00 U Nails. 1500.00 Cement. 20.00 Modular Socket Type Telephone Jack 10.00 20 Pair Telephone Distribution Box 10.00 No.8 Screws Of 63 / 75Mm. 1.00 Dewalt 880 Impact Wrench 3.00 Karigar Drill Machines 3.00 Dewalt Cutting Machine 2.00 King Toni Box Bit 6 To 32 Mm 2.00 Flat Spanner 6 To 32 1.00 Hydrallic Cripping Tool 3.00 Blowers Heavy Duty With Speed Controller 4.00 Clamp Meters 600 Amps 1.00 Megger 1000 Volts With Battery Operated 3.00 Ac Service Pumps With Indoor Covers 2.00 Ac Vaccum Pump 2.00 Double Guage Manifolds 1.00 Fulcrum Hydrallic Trolley 3000 Kg 3.00 R 22;410;32 Gas Cylinders Havy Duty 3Kg 4.00 Pipe Bender ( 5 / 8;1 / 4;1 / 2 ; 3 / 8 ) 2.00 Brazing Sets 3.00 Alluminium Ladders Heavy ( 5Feets ) 3.00 Alluminium Ladders Heavy ( 8Feets ) 1.00 Unforeseeen Items
Contract Date: Ref. Documents Contract Value : 24.91 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 1
13.
Water Resources and Irrigation #11299055 Technical Bid
Tender for Repairs To 400Kva Electrical Transformer At Lis Ratti Bhakta. , Repairs To 400 Kva Transformer Installed At Lis Ratti Bakhta By Disconnecting The Electric Transformer From The Input And Output Power Connections, Lifting Of Electric Transformer From Its Installed Position By Using Manual Labour And A Hydra And Then Shifting It To Workshop By Using Carriage Vehicle. Completely Dismantling The 400 Kva Transformer At The Workshop By Way Of Extracting Out The Damaged Coils, Lt Bushes, Ht Bushes, Rubber Gasket, Nuts And Bolts. Rewinding Of Ht Coils On One Damaged Transformer Leg With Standard Copper Winding Gauge And Proper Insulation & Taping. Reconditioning Of 3 Nos. Lt Leg Coils Using Quality Insulation Material. Repairs To Core Of Transformer By Replacing The Flashed Core Material. Heating Of Assembled Coils In An Oven For Proper Hot Air Process And To Obtained The Required Megger Value. Repairs To The Oil Tank By Welding To Make The Oil Tank Leak Proof And Air Tight. Properly Cleaning The Oil Tank With Scrubbers To Remove All Carbon Deposits. Lowering Of The Coils Inside The Sump Of The Transformer. Providing And Fitting Of Lt And Ht Bush Rod Sets, New Insulator, New Nuts And Bolts. Filling The Existing Transformer Oil In The Sump After Giving Heat Treatment/Reconditioning To Make It Moisture Free. Job Further Includes Providing And Filling 100 Liters Of Fresh Transformer Oil For Topping Up The Transformer. Refitting Of The Top Cover Of Transformer By Providing And Fitting Of New Top Gasket Sheets, Nuts And Bolts Of Appropriate Sizes. Testing The Continuity Of Each Phase And Securing All Connections. Shifting Back The Repaired Electric Transformer To The Site, Unloading And Installing At Site With The Help Of Hydra, Manual Labour, Connecting Of Ht And Lt Power Connections. Testing Of Transformer On No Load And Full Load. The Estimate Has Been Framed After Deducting The Rebate On Old Damaged Copper Coils .The Job Includes The Cost Of Materials, (Skilled/Unskilled) Labour Charges, Hydra Charges, Loading, Unloading, And Transportation Charges To & Fro, Testing And Installation, Tools And Tackles Used During The Execution Of The Job. Complete Job. Note: The Firm Should Offer Rebate On Old Material/Parts Except Damaged Copper Coils. The Tenderers Are Requested To Visit The Site And Quote The Rates As Per Site Conditions. Any Modifications/ Alterations Of The Job, Absolutely Necessary If Required At The Time Of Execution May Be Done As Per Actual Site Conditions. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
18.
Power #11272331 Technical Bid
Tender for Rate Contract For Supply Of Material Required For Repair/Maintenance /Restoration Of 33Kv Lines And 33/11Kv Receiving Stations In Respect Of Std-Iv Kalakote, For The Year 2026-27 Or Till Next Contract. , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 120 Mm2 , R) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 185 Mm2 , S) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 240 Mm2 , T) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 300 Mm2 , U) Cable Kits 11 Kv 3 Core (Straight Through Joint), Heat Shrinkable 400 Mm2 , V) Cable Kits 11 Kv Single Core (Straight Through Joint), Heat Shrinkable 630 Mm2 , W) Cable Kits 33 Kv Single Core (Straight Through Joint), Heat Shrinkable 630 Mm2 , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5 , Iii) 600/300/5-5 , Iv) 400/200/5-5 , V) 300/150/5-5 , Vi) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 1.6 Mva 33/11 Kv Transformer (Kg) , C) Breather For 3.15 Mva 33/11 Kv Transformer (Kg) , D) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , E) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , F) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , G) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , H) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , I) 12 Mm Copper Bush Rod Assembly For 33/11 Kv, 6.3 Mva Power Transformer With Oil Seal , J) Silica Gel , K) Oil Seal For 33/11 Kv Power Transformer , L) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Relays A) Numerical Relay (24-50 V) 3 O/C And 1 E/F Relay Of Different Make .(Scada Compatible) , B) Numerical Relay (24-50 V) 3 O/C And 1 E/F Relay Of Different Make.(Non-Scada Compatible) , C) Master Trip Relay 24-50 V ,Of Different Make , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , I) 11 Kv Disc Insulator (B & S Type) 120 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) Shackle Insulator , P) 11 Kv Guy Insulator , Q) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal (Isi Standard) , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape( Isi Standard) , Empire Tape , Para Plast Compound , Earth Wire 7/22 , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Gi Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Light Chargable Is Standard , Led Light (30/60 W) With Bracket And Fitting Complete (Is Standard) , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots Is Specification , Search Light / Dragon Light With In Built Charging System , Hand Gloves 33 Kv (Is Specification) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Earth Tester Heavy Duty Is Specifications , Megger 5000 V 10000 Meg Ohm Is Specifications , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , annual periodical maintenance Meter 0-400 A , Voltmeter 0-300V , Drill Machine With Stand Heavy Duty Is Standard , I/C Switch 200 annual periodical maintenance , Fire Extinguisher Cylinder For Electrical Sub Stations Of Relevant Is Specifications(6Kg) , Fire Buckets , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 33 Kv Hgf Set , 11 Kv H G Set , 11 Kv D O Set , 11 Kv G O Set , 11 Kv Link Set , Steel Tublar Pole 13 Mtr Long(St-410, Sp-69) , Steel Tublar Pole 13 Mtr Long(St410, Sp-56) , Steel Tublar Pole 13 Mtr Long(St410, Sp-33) , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories Make: Exide/Amaron , B) 36 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 36V Lead Acid Battery (Vrla) Bank Comprising Of 18 Nos Of 2 Volt Cells Of 100 Ah Capacity Make: Exide/Amaron Or Equally Reputed Make , D) 36 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 36Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Cell 2 Volt Is Specification Make: Exide/Amaron Or Equally Reputed Make , Lightening Arrestors (10 Ka, Make Oblum Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 11 Kv L.A. Set (Station Type) Polymer , B) 33 Kv L.A. Set (Station Type) Polymer , C) 11 Kv L.A. Set (Station Type) Porcelain , D) 33 Kv L.A. Set (Station Type) Porcelain , Control Cable A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle Of Different Make(G.E.C.,Crompton Greaves,Alstrom,Bhel Etc , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 , B) 11 Kv Single-Core Xlpe Cable 630 Mm2 , C) 11 Kv 3-Core Xlpe Cable 400 Mm2 , D) 11 Kv 3-Core Xlpe Cable 300 Mm2 , E) 11 Kv 3-Core Xlpe Cable 240 Mm2 , F) 11 Kv 3-Core Xlpe Cable 185 Mm2 , G) 11 Kv 3-Core Xlpe Cable 120 Mm2 , H) 11 Kv 3-Core Xlpe Cable 95 Mm2 , I) Pvc Cable 2-Core 12 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured 35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , Chemical Earthing Complete , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb(Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firms Conforming To Relevant Is With Latest Amendments). , 33 Kv C&R Transformer Panel With Differential Protection(Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firms Conforming To Relevant Is With Latest Amendments). , 33 Kv C&R Line Panel(Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firmsconforming To Relevant Is With Latest Amendments). , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Panther Conductor , Tarpin Oil , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Welding Set 3 Phase Heavy Duty Is Specification , Welding Set Single Phase Heavy Duty Is Specification , Led Bulb Is Standard 6/9 Watt , Led Bulb Is Standard 15/20/30 Watt , Cfl 30/60 Watt Is Standard , Led Flood Light 50 Watt Complete Is Specification , Laptop For Office Use Of Reputed Make , Ratched For Dog Conductor/Cable Puller , Comelong Clamp For Dog/Wolf Conductor , Wire Cutter 24 To 36 ( Heavy Duty) , Telescopic Running Saw Length 11 Mtr (Branch Cutter) , Cable Fault Locator (Digital) Is Speciation , Telescopic (Range 4Km To 5Km) , Discharge Rod/Earthing Rod 11Kv , Aluminium Ladder (Telescopic Type, 20 Feet) Is Standard , 11Kv Vcb Incomer Panel (Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firmsconforming To Relevant Is With Latest Amendments). , 11Kv Vcb Outgoing Panel (Siemens, Schinder, Easun Reyroll, Abb, Electric Field , S&S Or Equally Reputed Firms Conforming To Relevant Is With Latest Amendments). , Lifting Pulley Machine (5-8Mt) , Lifting Pulley Machine (3-5Mt) , Chequered Plate 5Mm To 10Mm , Oil Testing Machine Of Reputed Make , Multimeter Digital Of Reputed Make , Log Book For Receiving Stations , Discharge Rod/Earthing Rod 33Kv , 33Vcb Bottle Of Reputed Make , Galvanised Channel Iron Cross Arm 10Feet Long (10X50x6) , Galvanised Channel Iron Cross Arm 8Feet Long (10X50x6) , Galvanised Angle Iron Brace Arm 10Feet Long (50X6) , Galvanised Angle Iron Brace Arm 8Feet Long (50X6) , Galvanised Angle Iron Brace Arm 6Feet Long (50X6) , Galvanised Cross Clamps Of Sorts , Galvanised Guy Rod Assembly Complete , Ms Channel Iron Cross Arm 10Feet Long (10X50x6) , Ms Channel Iron Cross Arm 8Feet Long (10X50x6) , Ms Angle Iron Brace Arm 10Feet Long (50X6) , Ms Angle Iron Brace Arm 8Feet Long (50X6) , Ms Angle Iron Brace Arm 6Feet Long (50X6) , Ms Cross Clamps Of Sorts , Ms Guy Rod Assembly Complete , 11Kv Pt Of Reputed Make , Vacuum Interrupter Testing Kit Of Reputed Make , Relay Testing Kit Of Reputed Make , Primary Injection Set Of Reputed Make , Professional Electric Iron Cutting Machine With Handle (Rated Voltage 2 Kw To 2.5Kw) , Turn Ratiometer Of Reputed Make , 11Kv Vcb Tripping / Closing Coil , 33Kv Vcb Tripping / Closing Coil , Petrol Chainsaw Tree Cutter 18 40Cc , Petrol Chainsaw Tree Cutter 18 50Cc , Electrical Rescue Rod Frp Hv 6 Feet Length , 11Kv Vcb Trolly Suitable For Cg, Abb, Electric Field Etc. , Magnetic Drill Machine (Hd) , Bits Suitable For Magnetic Drill Mc Complete Set , Digital Insulation Tester 5Kv , Welding Set Portable Modern Type , Petrol Chainsaw Tree Cutter 18 50Cc , Petrol Chainsaw Tree Cutter 20 40Cc , Petrol Chainsaw Tree Cutter 20 50Cc
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
19.
Power #11267487 Technical Bid
Tender for Rate Contract For Procurement Of Material In Respect Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized , Procurement Of Material In Respect Of Std Ganderbal For The Year 2025-26 Or Till Next Stage Contract Is Finalized , 11 Kv Horn Gap Fuse Set 3 Phase 200A , 11Kv Link Rods For 11Kv Link Set 22 Feet Long With Insulating Bottom Grip Bamboo/Carbon Fibre , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 11 Kv Isolator, Double Break,3-Pole, 600Amp, Horizontal Mounting Type, With Earth Switch Complete Including Clamps And Fittings , 11 Kv 3-Core Current Transformer 800-400/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 750-375/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 600-300/5-5 A, ( Metering, Protection, Differential Core) , 11 Kv 2-Core Current Transformer 600-300/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 400-200/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 100-50/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 50-25/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 20-10/5-5 A, ( Metering, Protection) , 11 Kv Potential Transformer 110V, Accuracy Class 0.5 , Tension Fittings For 0.1 Acsr Conductor 70Kn , Tension Fittings For 0.15 Acsr Conductor 70 Kn , Tension Fittings For 0.2 Acsr Conductor 120 Kn , 185 Sqmm, 3Core , 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 3 Core ,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core, 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 240 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 120 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 120 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 11 Kv 630 Mm² Single Core Xlpe Cable Armoured, Frls (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , Tripping And Closing Coils Must Have Burden Between 250 To 350 Watts At 30V Dc With Housing , Tripping Coil Of 11Kv Alind Make Vcb , Tripping Coil Of 11 Kv Er/Vijai Make Vcb , Tripping Coil Of 11Kv Electric Field Make Vcb , Tripping Coil Of 11Kv Abb Make Vcb , Tripping Coil Of 11Kv Crompton Make Vcb , Tripping Coil Of 11Kv Stelmac Make Vcb , Tripping Coil Of 11Kv Sudhir/Schneider Make Vcb , Tripping Coil Of 11Kv Pascal Make Vcb , Closing Coil Of 11Kv Alind Make Vcb , Closing Coil Of 11 Kv Er/Vijai Make Vcb , Closing Coil Of 11Kv Electric Field Make Vcb , Closing Coil Of 11Kv Abb Make Vcb , Closing Coil Of 11Kv Crompton Make Vcb , Closing Coil Of 11Kv Stelmac Make Vcb , Closing Coil Of 11Kv Sudhir/Schneider Make Vcb , Closing Coil Of 11Kv Pascal Make Vcb , 33 Kv Link Set Heavy Duty- Post Type, 800A Complete , 33Kv Link Rods Fibre/Bamboo Oil Impregnated With Insulated Bottom Grip 30 Feet Long , 33Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm. , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type A , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type B For 0.2 Acsr Conductor , 30 Kv Lightening Arrestor Set, 10 Ka, Station Class, Zno, Polymer Gap Less (Set Consists Of 03 No.) With All Accessories Required For Installation. , 33 Kv Isolator Without Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Isolator With Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Current Transformer (33 Kv, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. Per Φ) 3-Core, 0.5 5P10, Ps-Class 3 Core- With All Accessories Required For Installation , 400-200/5-5 A (Metering, Protection And Differential Core ) , 250-125/5-5 A (Metering, Protection And Differential Core ) , 33 Kv Voltage Transformer (33 Kv/110 V, 1Φ, Multi-Core, Outdoor), (1No. Per Φ) With All Accessories Required For Installation , Tripping Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb) , Closing Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb, Stelmac Etc ) , 33 Kv Polymer Post Insulator 36Kv,170Kv Impulse, Creepage Distance 1224M , Earthing Complete (Spike Earthing Rod 20Mm,2.5 Mtr Long) , Galvanised Earthing Strips 50X6 Mm/ 25X3mm , Galvanised Nuts & Bolts Of Different Sizes And Sorts , Pg Clamps For 0.1 Acsr Conductor 400A Pressure Di-Cast , Pg Clamps For 0.15 Acsr Conductor 500A Pressure Di-Cast , Pg Clamps For 0.2 Acsr Conductor 630A Pressure Di-Cast , Prefabricated Galvanised Channel Iron/ Angle Iron Of Different Sorts As Required , Prefabricated Galvanised Flat Iron Of Sorts 50/25 8/6Mm Thick , Instrument, Tools And Other Equipments , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick With Sliding Mechanism , Bamboo Ladder 25 Long , 12V/7Ah Led Handheld Searchlight (Andslite/Philipls/Microtech,Fos) , Tool Kit Of Suitable Size With Tools ( Stanley / Taparia/Jon/Jk/ Make) Comprising Of :- Double End Spanners With Increases Or Decreased Sized Ends And D/Ring Type Following Sizes And Numbers Spanners 6-0, 7-8, 9-9-10, 10-11, 11-12, 12-13, 14-15, 16-17, 18-19, 20-21, 20-22, 24-27, 25-28, 30-32, Complete Set Cushion Grip, Pipe Wrench 12 Inch 1 No. 24 Inch 1 No., 12 Adjustable Chrome Plated Wrench, 8 Combination Plier Line Man Plier, 8 Long Nose Plier Length Nose Plier, 9 Crimping Plier Set, 230Mm-, 7 Length Cutting Plier, Hex Key(Ln Key) Set 11Pc Metric (1.5, 2, 2.5, 3, 4, 5,5.5, 6, 8, 10Mm 12Mm), 27Pc-1/2 Sq. Dr 12Pt Socket Set ( Comprising Of ) 20 Pc :- 1/2 Drive 12 Point Sockets: 10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,30,32Mm 6 Pc :- 1/2 Drive Accessories : 2 Pc Extension Bar: 5 And 10(125 And 250Mm) Universal Joint, 1 Pc :- Spark Plug Socket 6 Point 13/16, 1 Pc Sliding T-Bar 10(254Mm); 1 Pc Flip-Drive Rachet., 1/4 Torque Rench, 914Mm , 36 Inch Bolt Cutter (Taparia Make, 12 Hacksaw Frame With 12 No. Spare Blades, Steel Body Retactable Utility Knife With 12 No. Spare Knives, 12H 340Gms Ball Pien Hammer Wooden Handle, 16 900Gms Ball Pien Hammer Wooden Handle, 5 Mtr Measuring Tape, Cold Chesel 7/8 (22Mm), Centre Punch 8Mm (15/16 )X 115Mm(4 1/2 ), Good Quality Multi Meter ( Fluke, Motwane, Meggar Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. 24 Magnetic Torpedo/ Beam Level (3Vails) 300Mm -1 No. & 600Mm -1No., Files Flat/Round Type 8-12 Inch Long, Srew Driver Set Comprising Of 12 No.S Long Shank Having Star/Flat Type Tips With Heavy Duty Tefon Grips , Hv Detectors For All Voltages. (With Fiber Rod Telescopic) , Pliers (Make-Taparia/Stanley) , 11 Kv Hand Gloves ( Make 3M/ Crystal) , Earth Resistivity Tester (0-1000 Ohms) (Make-Motwane/Megger/ Fluke/Markoni) With Auto-Manual Options , Digital Insulation Resistance Tester 5000V (Make-Sonel/Megger/ Fluke/Equivalent) , 10 Feet A Type Ladder , Portable Welding Set , Portable Blue Lamp(Gas) , Portable Blue Lamp (Kerosene) , Insulation Tester And Continuity Tester 2.5 Kv Withvarious Kits (Make- Fluke/ Megger/Equivalent) , Clamp Meter/ Multi Meter ( Fluke, Motwane, Meggar/Meeca Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. , Heavy Duty Pulling & Lifting Machine 5 Mt , Control Relays With 3Oc+1Ef 2 Element Based Digital Of Following Make. , Mit- 114/104 (Er) Make. , Lnt M314a , Schneider , Simens 7Sr , Crompton 14C , Crompton 14Cn , Ashida 131A , Ashida 141 A/B , Ashida Adr241a , Ashida Adr242b , Abb Ref 615 , High Speed Master Relay With 12-63Vdc, 12-220 Vac Coil And 4 No+4Nc Driver Contacts , Battery Bank 30 V,100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type,High Impact Polyprophelene Copolymer Container,Flame Retardant (Exide/Amaron/Shoto/Hbl Make) , Battery Bank 36 V, 150 Ah Ultra Low Maintenance Tubular Battery Bank Compromising Of 3 No. Batteries Each Of 12 Volt (Hbl/Exide/Amaron/Luminous) , Battery Charger 36V, 40/60A With Full Wave Power Diode/Scr Based Recetification And Ripple Filtration. Avr Based Semi Digital With Inbuilt Autotransformer/Variant And Auto Manual Mode Having Digtal Precision Type/ Measuring Instruments, Led Type Indication, Inbuilt Buzzer/ Hoter Alarm During Technical Snags. The Charger Operating Ranges Must Be From 110V To 260 Vac Input Without Attoring Dc Output Through Smps , 7.5 Kva Servo Stablizer Copper Wound With Input Voltage Range 90V To 260V , Distilled Water For Batteries , Power Diodes P-Type/ N-Type ( 40 To 100 A) With Heat Shink , Charger Coil 240/36V Ac , Avr Card Compatile With Existing Chargers , Dc Volt Meter ( 0-60V) , Dimmer/Variac 110V To 260Vac , Power Transformer Equipments , Winding Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes Lv (Make-(Emco/Yoca/Excel) , Oil Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes (Make-(Emco/Yoca/Excel) , Power Oil Conforming To Is:335 Standards , 33 Kv Bushing For 10 Mva Power Transformer , 33 Kv Bushing For 6.3 Mva Power Transformer , 33 Kv Bushing For 5/4/3.15 Mva Power Transformer , 33 Kv Bush Rods For 10 Mva Power Transformer , 33 Kv Bush Rods For 6.3 Mva Power Transformer , 33 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11 Kv Bushing For 10 Mva Power Transformer , 11 Kv Bushing For 6.3 Mva Power Transformer , 11 Kv Bushing For 5/4/3.15 Mva Power Transformer , 11 Kv Bush Rods For 10 Mva Power Transformer , 11 Kv Bush Rods For 6.3 Mva Power Transformer , 11 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11Kv Outdoor Breaker Bushing , Oil Sealing For 33/11Kv Bushing Suitable For 1.0/3.15/2.5/6.3/10Mva , Miscellanous Items , Aluminum Thimble 120 Sqmm 3Mm Thick , Aluminum Thimble 185 Sqmm 3Mm Thick , Aluminum Thimble 240 Sqmm 3Mm Thick , Aluminum Thimble 300 Sqmm 3Mm Thick , Aluminum Thimble 400 Sqmm 3Mm Thick , Aluminum Thimble 630 Sqmm 4Mm Thick , Flexible Insulated Copper Bus/ Braid , Copper Bus Bars 12 Mm Thick , Aluminum Bus Bars 12 Mm Thick , T-Clamps For 0.1 Acsr 400A Presure Di-Cast , T-Clamps For 0.15 Acsr 500A Presure Di-Cast , T-Clamps For 0.20 Acsr 630A Presure Di-Cast , Isolator Pad Clamps 630A Presure Di-Cast , Single Phase Water Pump Motor, Power: 1 Hp , Led Lamp 15 Watt, B-22 Type (Make-Syska/Havells/Wipro/Surya/Ce/Gm) , 50 Watt Led Street Light With Fitting Complete (Make-Syska/Havells/Wipro/Surya/Ce/Gm) Ip-67 , Automatic Voltage Stablizer 5 Kva Copper Wound , 1.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 2.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 4 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 16 annual periodical maintenance Top (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Switch (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Socket (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Combine (Socket/Switch) (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Extension Board With 5 Socket With Fuse And Switch (Make-Anchor/Havells/Crompton/Equivalent) , Pvc Flexible Pipe 1/2 Dia , Ppr Pipe 0.75 Dia , Ppr Pipe 0.5 Dia , Poly Propline Rope-20-30 Mm , Motorized Wood Cutter (58Cc 3.5Hpchain Saw With 22 Inch Cutter Bar Power Full Engine) , Pt Clamps , 33Kv La Clamps 6Mm Thick , Pad Clamps (Aluminuim /Bi Metalic 600A)Presure Di-Cost , Baby Insulators With Nuts & Bolts , 33Kv Ct Clamps ( Threaded And Band Type Cu Made) Tin Coated , Crimping Tool Xple Cable ( Hydraulic Type Upto 120 Sqmm To 630 Sqmm) , Korean Mink Blanket 220X240 Cm 4Kg Weight.Rate Be Quoted Per Kg , Pvc Insulated Copper Bus Bar (50 Mm X 12 Mm) Including Nuts And Bolts 1250A , 11 Kv Vacuum Interrupters (800A/600A) Suitable For Vijai, Er, S&S, Alind, Crompton, Electric Field, Abb, Stelmac, Pascal. Indoor/Outdoor Breakers. , 11 Kv Vacuum Interrupters (800A/600A) Suitable For L&T, Schneider, Sudhir Etc. , 11 Kv Vacuum Interrupters Housing Of Below Mentioned Make. , Vijai And Easun Reyrolle (Per Phase) , Alind (Assembly Upper Set/ Lower Set). , Abb/Electric Field/Crompton/S&S ( Per Phase) , Sudhir And Schneider (Per Phase) , Outdoor Type Pcvcb Upper And Lower Part(Per Phase) , 11 Kv Vcb Equipments Below (Make-Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Voltmeter 11Kv/110V , Ampere Meter , Selector Switch- 16 Amps Vss/Ass , Led Panel Indicators , Push Button With 2No+2Nc , Master Tripping Relay With 4No+4Nc , Hrc Fuse With Base -16 Amps , Connecting Ribs , Auxilary Switch With 8No+8Nc Complete With Bracket And Lever , Auxilary Switch With 12No+12Nc Complete With Bracket Lever , Auxilary Relay -30 A , Trip Circuit Supervision Relay , Bell/Buzzer , Arching Chamber , Tripping Mechanism , Re-Setting Links , Operating Shaft , Shower Contact , Isolating Sockets , Brass Chamber , Lifting Rods , Rollers , Closing Shaft , Contact Bar , Aluminum Chamber , Spring Tension Rod , Gear Assembly , Bmr Mechanism Complete , 33 Kv C&R Panel Equipments (Make Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Bucholz Relay , Winding Temperature Relay , Oil Temperature Relay , Tripping Relay , Alarm Relay , Master Tripping Relay With 4No+4Nc , Tnc Switch 25 Amp. , Energy Meter Of Secure Make With Latest Series Premier 500 Of 11Kv Level And 33Kv Level With 5A Secondary. 11Kv/110V-5A / 33Kv/110V-5A , Electronic Hooter , Ampere Meter With Selector Switch , Voltmeter With Selector Switch , Hrc Fuse With Base , Bell/Buzzer , 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls , 12 Core . , 8 Core , 6 Core , 4 Core , 2 Core , 33 Kv Vcb Equipments (Make : Electricfield/Crompton/Abb/Bhel/Sudhir/Pascal/Beeco Lawrie/Megawin) , 33 Kv Vacuum Interrupter 1250A , 33 Kv Porcelain Post Insulator (Msli 1200+) , Operating Rods , Tripping/Closing Coils , Motor Charging 240, 1Cb, 0.1 Kv , Gasket , Operating Shaft , Mechanism Housing , Gear Assembly , Vacuum/Gas Charging Valve , Input/Output Housing Terminal Pads Din Pail Mounted Type , Xlpe Lt Cable 3.5 Core, Armoured, Fire Resistant Of Sizes , 95 Sq.Mm , 120 Sq.Mm , 185 Sq.Mm , 240 Sq.Mm , 300 Sq.Mm , 400 Sq.Mm , 2Mva/1Mva/630Kva/400Kva/250Kva/100Kva ,33/0.433 Kv, 3-Phase Distribution Transformers Eqiments: , 1600 annual periodical maintenance 4P Acb Drawal Type , Breaking Capacity 50Ka With Enclosure , Mccb ‐ 630 Amps , 36 Ka, 4P With Box Ics=100% Icu At 415 (Ka Rms) , Mccb ‐ 400 Amps , 36 Ka, 4P With Box , Mccb ‐ 250 Amps , 36 Ka, 4P With Box , Mccb ‐ 160 Amps , 36 Ka, 4P With Box , Mccb ‐ 1200 Amps , 36 Ka, 4P With Box , 120 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 240 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 400 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 630 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 33/0.433 Kv Transformer Lv Bushing Suitable For 100Kva To 2 Mva: , 33/0.433 Kv Transformer Lv Bush Rods Suitable For 100Kva To 2 Mva: , Safety Equipments , Safety Helmets Make-3M/Akamgo/ Hilson) , 33Kv Hand Gloves (3M/Crystal/Honeywell/Meeco/Jyot) , Safety Shoes Valcanised Rubber Made (Make-Allen/ Hillson/ Gasoline/Liberty/Acme/Bata/Neosafe/Honetwell) , Safety Belts Shock Absorber Type (Make-3M/Neo) , Safety Glasses (Make-Stanley/ 3M / Allen) , Safety Jackets (Make-Allen/ Hillson/ Gasoline) , Rain Protective Suit Complete- Pant And Jacket Ip-67 Protected , Fire Extingiusher Co₂ Type Of 6.5 Kg Capacity For Control Room , Fire Extingiusher Abc/Dpc Type Of 9 Kg Capacity For Control Room , Refilling Of Empty/Expred Fireextinguishers , Rubber Mat 1Mx2m 19Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
20.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
21.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Jun 09, 2026 Contract Value : 83,638
Government Departments No of Bidders 1
West Bengal View Result →
24.
Agriculture #11246518 Technical Bid
Tender For Supply Of General Electrical Goods- 2 Copper Cable Lugs Dowells Make 3 16 Mm 4 25 Mm 5 50 Mm 6 70 Mm 7 95 Mm 8 Aluminium Cable Lugs Dowells Make 9 35 Mm 10 50 Mm 11 70 Mm 12 95 Mm 13 120 Mm 14 185 Mm 15 240 Mm 16 300 Mm 17 400 Mm 18 Condensor Ancap Make 19 2.5 Mfd 20 3.15 Mfd 21 4.00 Mfd 22 6.00 Mfd 23 8.00 Mfd 24 10.00 Mfd 25 Heavy Duty Battery Make Eveready 9 Volt 26 Eveready Pencil Cell 1.5 Voltsize Aa 27 Led Rechargable Tourch Light Eveready Make 28 Foot Switch Element Make Bch 29 Puch Button & Element Make Teknic Red 30 Puch Button & Element Make Teknic Green 31 Push Button Element -E1 Cat No Se-06 Teknic Make 32 Led Tube Light 12 Watt Length 2 Feet Make Bajaj 33 Led Tube Light 12 Watt Length 2 Feet Make Orient 34 Led Tube Light 12 Watt Length 2 Feet Make Surya 35 Finned Type Air Heater 1000 Watt 220 Volt 36 Finned Type Air Heater 2000 Watt 220 Volt 37 Complete Electric Coil Heater 1500 Watt 38 Heater Element 1500 Watt 39 Slipring Holder Mounting For 7.5 Hp Motor 40 Slipring Carbom Holder For 7.5 Hp Motor 41 Slipring For 7.5 Hp Motor Id 65 Mm Od 118 Mm L 84 Mm 42 Pt Bult 100 Watt 240 Volt Make Bajaj 43 Pt Holder Bakelite Make Anchor Make 44 Pt Button Holder Anchor Make 45 Pt Bulb 100 Watt 24 Volt Anchor Make 46 Electronic Fan Regulator Anchor Make 47 Metal Exhaust Fan Blade 18\ With Hub 48 Metal Exhaust Fan Blade 12\ With Hub 49 Double Tail Carbon Brush Size 22X32X40 Mm 50 Double Tail Carbon Brush Size 16X32X38 Mm 51 Double Tail Carbon Brush Size 50X25X50 Mm 52 Double Tail Carbon Brush Size 50X25X65 Mm 53 Double Tail Carbon Brush Size 16X18X38 Mm 54 Soldring Iron 25 Watt Make Tony 55 Soldring Iron 35 Watt Make Tony 56 Soldring Waire 1 Mm 250 Gram Roll 57 Angle Grinder 5\ Make Bosch 58 Metal Drill Bit Set Size 10 Mm Make Bosch 59 Wall Drill Bit Size 6.5 Mm 60 Had Driver Megger 500V Make Waco 61 Tong Tester Clamp Meter Make Meco 62 Contineuty Tester Make Taparia 63 Screw Driver 4&2 Way 12\ Make Taparia 64 Line Tester Make Taparia 65 Insulated Pliers Make Taparia 66 D Spaner Set 6X7 To 30X32Mm 67 Ring Spaner Set 6X7 To 30X32Mm 68 Allen Key 1.5 Mm To 10 Mm 69 Led Flood Light 50 Watt Make Bajaj 70 Led Flood Light 50 Watt Make Orient 71 Led Flood Light 50 Watt Make Surya 72 Led Flood Light 100 Watt Make Bajaj 73 Led Flood Light 100 Watt Makeorient 74 Led Flood Light 100 Watt Make Surya 75 Led Flood Light 200 Watt Make Bajaj 76 Led Flood Light 200 Watt Make Orient 77 Led Flood Light 200 Watt Make Surya 78 Led Bulb 9 Watt Make Bajaj 79 Led Bulb 12 Watt Make Bajaj 80 Led Tube Light 20 Watt Make Bajaj 81 Led Tube Light 20 Watt Make Surya 82 Led Tube Light 20 Watt Make Orient 83 Piano Type Switch 6 Amp Make Anchor 84 3 Pin Socket 6 Amp Make Anchor 85 Combined Switch With Box Anchor 16 Amp 86 3 Pin Top Make Anchor 6 Amp 87 Steel Grip Pvc Tape 88 Empire Tape 1 \ 89 Crc 2-26 90 Loc Tite 641 50 Ml 91 Plycab Make Ceiling Fan 1200 Mm White 92 Crompton Ceiling Fan 1200 Mm White 93 Bajaj Make Ciling Fan 1200 Mm White
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
27.
Water Resources and Irrigation #11223260 Price Bid
Tender for Repair Of Control Panel And Providing/Fitting Of Foot Valve Of Priming Pump Along With Allied Works At Lis Khawas Khan. , Repair And Reconditioning Of Existing 125 annual periodical maintenance Lt Control Panel Of 415 Volts, Ac 3 Phase, 50 Hz At Lift Irrigation Station Khawas Khan Serving 2 Nos. Motors Of 20 Hp Each By Way Of Replacement Of Faulty/Non-Functional Multispan Mpd 192 (Or Equivalent Isi Standard Make) Motor Protection Device/Fault Analyzer After Extracting The Old Damaged One By Way Of Disconnecting All The Existing Wiring Connections At Its Terminals And Removing It From The Panel Enclosure. providing and Fixing Of New Multispan Mpd 192 Or Equivalent Protection Relay In Its Place And Reconnecting All The Control Wiring As Per The Original Wiring Scheme. Setting/Configuration Of The New Protection Device For 20 Hp Motor Parameters Including Overload Threshold, Underload/Dry Run Detection Level, Over/Under Voltage Limits, Phase Unbalance And Earth Leakage Settings As Per Motor Nameplate Data. Replacement Of 3 Nos. Existing L&T Mnx 25 (25 Amp) Air Break Contactors Of The Star Delta Starter Of Motor No. 1 Which Are Undersized For 20 Hp Motor Rating With 3 Nos. New L&T Mnx 40 (40 Amp) Or Equivalent Isi Standard Make Air Break Contactors Comprising Of 2 Nos. 40 annual periodical maintenance Contactors For Main And Delta Duty And 01 No. 40 Contactor For Star Duty After Extracting The Old Undersized Contactors By Way Of Disconnecting The Power Cables And Control Wiring And Removing The Old Contactors From Their Mounting Arrangement. Reconnecting All Power Cables Of Adequate Current Carrying Capacity And Control Wiring To Appropriate Terminals Of The New Contactors As Per The Star Delta Circuit Including Interlocking Connections Between Star And Delta Contactors To Complete The Star Delta Starting Circuit Of Motor No. 01. Replacement Of Any Faulty Led Indicator With A New Led Indicator Of Equivalent Rating, Colour Coding And Size After Extracting The Old One By Way Of Disconnecting The Existing Wiring Connections And Making Proper Connections To The New Indicator. providing and Fixing Of 1 No. New Reset/Selector Switch In Place Of The Existing Faulty Small Black Reset Switch After Extracting The Old Damaged Switch By Way Of Disconnecting The Existing Wiring Connections, Removing The Old Switch Fitting The New Switch Of Equivalent Type Its Place. Reconnecting The Control Wiring To The New Switch To Restore The Manual Reset Function Of The Motor Protection Relay After A Protection Trip Event. Complete Inspection Of All Internal Control Wiring Of The Panel By Way Of Checking The Insulation Condition Of Flexible Copper Cables, Tightness Of All Crimp/Ferrule Terminations At Terminal Blocks, Contactor Coil Terminals, Push Button Terminals, Indicator Lamp Terminals And Protection Relay Terminals. Replacement Of Any Damaged Or Deteriorated Wiring As Per Actual Site Requirement. Verification Of Correct Phase Sequence Of Incoming Supply Using Phase Sequence Meter Before Energization Of The Panel. Testing And Commissioning Of The Repaired/Upgraded Panel On Full Load By Way Of Energizing The Panel After Completion Of All Repair Works, Verifying Healthiness Of All Three Phase Indicator Lamps At Incoming Section, Checking Voltmeter And Ammeter Readings On All Phases Using Selector Switches, Testing Start/Stop Operation Of Both Motors, Verifying Correct Star To Delta Changeover Of Motor No. 1 Starter, Verifying Display And Protection Functions Of The Motor Protection Devices On All Phases And Recording The Full Load Running Current Of Both Motors. Underground Laying Of Aluminum Cable From From Pump Room To The 100 Kva Distribution Transformer Approximately 20 Feet Apart, By Way Of Excavation Of A Trench Of 9 To 12 Inches Depth And 20 Feet In Length Using Manual Labour With Tools And Tackles. Inspection Of Cable And Insulation Of All Joints And Any Other Locations Found Requiring Insulation During Inspection By Way Of Proper Wrapping With Good Quality Pvc Insulation Tape In Multiple Overlapping Layers So As To Ensure A Moisture Proof And Mechanically Sound Insulation At All Such Points Along The Cable Run. Laying Of The Cable In The Excavated Trench In A Neat And Orderly Manner With Adequate Slack Provided At Both Ends To Facilitate Making Of Electrical Connections. The Cable To Be Laid Without Kinks, Twists Or Sharp Bends So As To Avoid Mechanical Damage To The Cable Insulation. Filling Of The Trench With Excavated Earth With Proper Compaction Using Manual Labour Along With Requisite Tools And Tackles. Removal Of The Old/Damaged Foot Valve Of Priming Pump Of 2 Hp From The Suction Pipe By Way Of Cutting The Rust Nuts And Bolts. providing and Fixing Of 01 No. New 2.5 Inch Foot Valve Of Standard Make With Appropriate Size Of Flange, New Nuts And Bolts Of Appropriate Size Along With Rubber Gaskets/Packing Of Suitable Thickness So As To Ensure A Leak Proof Joint. The Job Also Involves Cutting Of Rusted/Damaged Flange From The Suction Pipe Piece End And Providing And Welding Of New Flange Of Requisite Size To The End Of Suction Pipe Piece. Lowering Of The Suction Pipe Assembly Along With The Newly Fitted Foot Valve Back Into The Canal To Its Original Position Using And Manual Labour. Securing Of The Pipe In Its Correct Position As Per Original Installation. Testing And Commissioning Of The Priming Pump With The New Foot Valve By Way Of Priming The Pump And Running It On Full Load To Verify Proper Suction, Absence Of Air Leakage At The Foot Valve And Correct Pumping Action. Rewinding Of 2 Hp, 3-Phase, 415V, 50 Hz Priming Pump Motor At Lis Khawas Khan By Way Of Dismantling Of Motor Assembly From Pump Set Using Tools And Tackles And Carriage To Workshop. Stripping Of Old Burnt/Damaged Stator Winding From Stator Slots And Cleaning Of Stator Core And Slots. Rewinding Of Stator With New Standard Copper Winding Wire Of Appropriate Gauge In Same Winding Configuration As Original With New Slot Insulation Liner Paper Of Appropriate Class. providing and Fixing Of New Connecting Leads And Terminal Connections Of Appropriate Size. Impregnation Of Completed Winding With Class B/F Insulating Varnish By Way Of Dipping And Oven Baking. Reassembly Of Motor And Replacement Of Bearings If Found Defective. Fabrication And providing and Fixing Of New Terminal Plate In Place Of Existing Worn Out/Damaged Terminal Plate Of Priming Pump Motor By Way Of Removal Of Old Terminal Plate And Fabrication Of New Terminal Plate From Bakelite Sheet Of Appropriate Size And Thickness. providing and Fixing Of New Isi Standard Brass Terminal Studs, Nuts And Washers Of Appropriate Size And Current Rating. Proper Insulation Of Terminal Connections By Way Of Pvc Sleeving And Ferrules Of Appropriate Size. Reconnecting Motor Winding Leads To New Terminals And Testing For Proper Insulation Resistance And Contact Continuity Using Megger. Back Shifting Of Rewound Motor To Site, Fitment And Testing On Full Load. Complete Job Includes Cost Of All Materials, Consumables Including Rebate On Old/Damaged Components, Carriage Of Material To Site, Labour Charges Of Skilled As Well As Semi-Skilled Labour, Testing And Commissioning Charges At Lis Khawas Khan. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
28.
Power #11223257 Technical Bid
Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
29.
Public Administrative Department #11218095 AOC
Bids Are invited for Crimping Tool - 16 sq mm to 95 sq mm , Wire Cutter and Stripper - 150 mm , Contactor and auxiliary contacts - 3 phase 415 volt 32 Amp with 2 NOand 2 NC , Hydrometer - good quality , Hand Drill Machine - 0 to 6 mm capacity , Knife Switch DPDT - 16 Amp , Knife Switch TPDT - 16 Amp 440 V , Earth Plate - 60cm X 60cm X 3.15mm CopperPlate 60cm X 60cm X 6mm GI Plate , Earth Electrode - Primary Electrode 2100x28x3.25mmSecondary Cu Strip 20x5mm , MCCB - 100Amps Triple pole , ELCB - 25Amps double pole and In 30 mA , RCCB - 25Amps and double pole , Rheostat Sliding type - 2 Amp 0 to 1 Ohm , Various type lamp - Halogen Incandescent Lamp Fluorescent tube HP mercury vapor Lamp High-pressure sodium Lamp Low-pressure sodium Lamp LED Lamps , Bus bar with brackets - 1 mtr each , Rubber mat - 2 mtr x 4 mtr x 1 inch size , Digital Multi Meter - DC 200mv to 1000v 0 to 10A and AC200mv to 750v 0 to 10A resistance 0 to 20M and 3.5 digit , Milli Voltmeter - entre zero analog portable box type housed in Bakelitecase 100 to 0 to 100 mV , Ammeter MC analog - 0 to 500 mA 0to5 A 0to25 A , AC Ammeter MI - zero to 1 A zero to 5 A zero to 25 A , Digital Wattmeter - 230 V 1 KW 50 Hz , Power Factor Meter Digital - 440 V 20 A Three Phase portablebox type , Magnetic Flux Meter - 0 to 500 tesla , Tachometer - Analog Type 10000 RPM , Megger - Analog 500 V , 3 point DC Starter - For 2.5 KW DC motor , 4 point D.C. Starter - For 2.5 KW DC motor , AC Starters - Resistance type starter star delta soft starter , Function Generator - 2 to 200 KHz Sine SquareTriangular 220 V 50 Hz Single Phase , Soldering Iron - Temperature controlled 50 Watt 230 Volt , Discrete Component Trainer - Discrete Component for diode andtransistor circuit with regulatedpower supply +5 0- 5 V +12 0-12 V , Smart Meter - 1 Phase Smart Energy Meter 3 Phase Smart Energy Meter , Measuring Steel Tape - 5 meter , Combination Plier Insulated - 200 mm , Screwdriver Insulated - 4mm X 150 mm Diamond Head , Screwdriver Insulated - 6mm X 150 mm , Electrician screwdriver - thin steminsulated handle 4mm X 100 mm , Heavy Duty Screwdriver insulated - 5mm X 200 mm , Electrician Screwdriver - thin steminsulated handle 4mm X 250 mm , Punch Centre - 9mm X 150 mm , Knife Double Bladed Electrician - 100 mm , Neon Tester - 500 V , Steel Rule - Graduated both in Metricand English Unit 300 mm with precision of 1/4 mm , Hammer cross peen with handle - 250 grams , Scissors - 25 cm , Garment Hangers - good quality , Seam Ripper - good quality , Tailor s Card Scale Triangular - good quality , Tailors Square - Plastic , French Curve - Set of three , Thread Cutter - 24 INCH , Scale plastic - good quality , MEASURING TAPE - 150CM , Multi meter - 0 to 5 100 200 500 milli-amperes0 to 150 300 600 V AC or DC , Ammeter Mi - 0 to 30 Amp panel board , Ammeter MC - 0 to 500 mA , Solid State Solar Based Single Phase Energy Meter Bidirectional - 5 to 30 Amps 240 Volts , Ammeter MI - 0 to 5Amp Panel board type , Ammeter MI - 0 to 10 Amp panel board mounting type , Ammeter MC Centre zero - 5 to 0 to 5 Amp , Magnetic Flux Meter - 0 to 500 tesla , Lux meter - lux meter LCD read out 0.05 to 7000lumens with battery , Hydrometer - good quality , Hydraulic crimping tool - for UG cablecrimping with bits 20 Sq mm to 250 sq mm , Bar magnet - good quality , Small crimping tools assorted - 10 to 100 mm 5 Nos , Rubber matting - 2 meter x 1 meter x 9 mm , Set of Wall jumper octagonal - 37mm X 450mm and 37 X 600mm , Pliers round nose insulated - 200 mm , Firmer chisel - 1 inch , Gauge wire - imperial stainless steelmarked in SWG and mm Wire Gauge Metric , File flat - 300 mm rough , Pipe vice - Cast Iron with hardenedjaw open type 100 mm , Insulators including hardware fitting - Pin Type and shackle type and egg type andsuspension type , Knife Switch DPDT - 16 Amp , Knife Switch TPDT - 16 Amp 440 V , Bus bar with brackets - 1 mtr each , Electrician Helmet - Yellow Colour , Safety belt - with provision forkeeping tools , Solar Street Light - 12V 75Ah battery 75 Wp solar panel12V 10A dusk to dawn chargecontroller 60 W LED lights and 9 mheight pole all dismountable , Solar Traffic Light - 12V 75Ah battery 75 Wp solar panel12V 10A dusk to dawn chargecontroller 15 W LED lights with suitablecolors and 9 m height pole alldismountable , Solar DC pump - 24V 1 HP , Lead Acid battery 75Ah - 12 V , Solar street light lamp set - 12 V 18 or 24 watts , Steel rule - 300 mm , Terminal screw Driver - 75 mm Connector , Knife Electrician - DB , Hammer Ball peen - 0.25 Kg , Plumb bob - 115 grams , Combination pliers insulated - 200 mm , Try square - 200 mm , Spanner set DE - Set of 6 from 6x7 to 16x7 , Screw driver set set of 5 - 100 to 300 mm , File round 2nd cut - 150 mm , Soldering iron - 60 W 230 V , Steel measuring tape - Pocket type , Bradawl - 150 mm x 6mm square pointed , Set of Rowel punch - 8 10 mm , wooden mallet - 1 kg 75mm x 15mm , Wheostone bridge - good quality , Belt Tensioner gauge - good quality , Different type of Engine Bearing model - good quality , Different type of piston model - good quality , Drill twist various sizes - 1.5 mm to 15 mm by0.5 mm , Growler - good quality , Hacksaw frame - Adjustable 20 to 30 cm , Hammer Mallet - good quality , Hand vice - Up to 37 mm , Injector testing set Hand tester - good quality , Left cut snips - 250mm , Oil Stone - 15 cm x 5 cm x 2.5 cm , Oscilloscope - 20MHz , Dividers with spring - 15 cm , Pliers combination - 20 cm , Spindle key - good quality , Hammer sledge - double faced 4 kg , SS tape - 5 meters flexible in case , Multiangle magnetic clamp set - Metal base 18x10x10 cm , Vernier caliper - 150 mm , Drill twist Taper shank - 8 mm to 20 mm by 0.5 mmHSS , Taps and dies complete set - 5 6 8 10 and 12mm set of 5 , File feather edge smooth - 150 mm , File triangular smooth - 200 mm , File square second cut - 250 mm , File triangular second cut - 200 mm , File half round second cut - 250 mm , File half round bastard - 250 mm , File round bastard - 250 mm , File hand second cut - 150 mm , File card Wire Brush - 3 inch x5 inch size brass or steelwire , Pliers combination insulated - 150 mm , Clamp C - 200 mm , Scraper flat - 150 mm , Scraper triangular - 150 mm , Scraper half round - 150 mm , Power tools for fastening - Capacity 10 to 18mm , Different Profile gauges - Plate type Fordemonstration Metric standard , Knurling tool - Diamond straight andDiagonal good quality , Indexable boring bar with inserts - 1 inch shank , Standard Tap screws - M3 M4 M5 M6 M8 M10 M12 M14 M16 , Lapping plate - Dia 6 inch , Drill gauges - Letter drill gauge A to Z Number drill gauge 1 to 60Metric drill gauge 1.5mm to12.5mm 30 holes , Cast Iron Globe Valve Flanged type - 150NB Class 150 FlangeANSI12 B16.1 , CI Sluice Gate valve flanged type - 150NB Class 150 Flange ANSI125 B16.1 , Stop cock - 25NB 2 way Threaded end , Slip on Forged steel Flange - 150NB ANSI B16.5 Class 150 , Pulleys for V-belt or Flat belt - to fit on 50mm dia Shaftwith key slot , Hollow punch - Straight Shank Hollow PunchSets 5 to 12mm , Bearing extractor - Universal gear puller 2 or 3jaws adjustable , Pulley extractor - good quality , Flat headed hammers with handle. - good quality , Planishing hammer. - good quality , Snip bent Left Cut - 250 mm , Stake hatchet with Leg - 300 X 200 X 20 mm , Arm strong type tool bit holder - Left hand , Arm strong type tool bit holder - Straight , Try Square - 150 mm blade , Scriber - 150 mm , File flat second cut - 250 mm , Hacksaw frame fixed type - 300 mm Total Quantity : 1092
Contract Date: Ref. Documents Contract Value : 6.99 Lakh
Government Departments No of Bidders 10
Contract Date: Ref. Documents Contract Value : 4.70 Lakh
Boards / Undertakings / PSU No of Bidders 1
31.
Power #11206303 Price Bid
Tender for Contract For Supply Of Key Materials Required For Maintenance Of 33/11Kv Receiving Stations Along With Their Lines Under The Jurisdiction Of Std Bijbehara During The Year 2026-27 , Electrical Store/Workshop Items/: As Per Is Standards , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Incommer) As Per Technical Specifications Of Rec Std , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Outgoing) As Per Technical Specifications Of Rec Std , 33 Kv Vcb (36 Kv, 1250A, 26.2 Ka, Outdoor Type) As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Out Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv Isolator With Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Isolator Without Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Outdoor, Oil Cooled, Live Tank, Single Phase , 3 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection,0.5 For Metering & Ps For Differential With Ratio 800-400/5-5-5A ,600-300/5-5-5A , 500-250/5-5-5A, 400-200/5-5-5A (Per Set Of 3 Pieces) , 33 Kv Outdoor, Oil Cooled, Copper Wound , Single Phase , Pt Set With Rated Primary Voltage 33000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 (Per Set Of 3 Pieces). , 33 Kv Lightening Arrestors (30 Kv, 10Ka, Station Class, Zno, Porcelain/Polymer) Gap Less(Per Set Of 3 Pieces). , 33 Kv Post Insulator (Polymer/Porcelain 36Kv, 170Kv Impulse) , Galvanised Steel Structures(6 G I Pipe With Top,Base & Grouting Bolts) As Per Rec , 11Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 2.5 Sqmm 2 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 4 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 6 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 8 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , L T Cable 3 1/2 16 Sq.Mm Core Armored , Al Conductor Sheathed Pvc Insulated (Std Make) , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Or Raychem Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 120Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 120Qmm , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 11 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb, Electric Field, Sudhir Or The Like , 11 Kv Indoor Type,Dry,Resin Cast, Single Phase , 2 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection & 0.5 For Metering Preferably Of Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make Having) With Ratio 800-400/5/5,600-300/5-5,400-200/5-5 (Per Set Of 3 Pieces). , 11 Kv Indoor ,Dry, Copper Wound , Three Phase , Pt Set In Ms Enclosure With Rated Primary Voltage 11000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 , 11 Kv Lightening Arrestor Set( Station Type),Outdoor, Metal Oxide Gapless As Per Isi Specifications.(Per Set Of 3 Pieces). , Digital Protection Relay Non-Communicable Model Type 141A (Ashida/Er Make) 3 O/C +1 E/F For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make . Auxillary Voltage 30V Ac/Dc Confirming To Iso 9001:2008 Standards. , Master Trip Relay 24-50V For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make. , 36V , 200Ah Battery Bank (Comprising Of 3 No Batteries Of 12 V Each) Conforming To Iec60896-21/22, Lead Acid Type Of Exide Make , 36 V,200 Ah , Float-Cum-Boost Battery Charger,Copper Wound,Air Cooled, With Full Wave Rectification With Heat Sink & 40A Diodes, Ae Make Measuring Instruments, 16Swg Steel Body Sheet, For 15A,220 V, 1Phase, 50 Hz Ac Input Supply Along With Ac/Dc Terminal & Earthing Slot, Correction Time 10Sec, Std Make , 5Kva Servo Motor Control Voltage Stablizer With Input 100V & Output 220V,Air Cooled,50 Hz,16Swg Steel Body, Copper Wound , Correction Time 10 Sec, Std Make , Auxillary Switch Suitable For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Panel Bush For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Bush(Bus Bar Spout) For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Interruptor Housing For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Limit Switch For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Contact/Female Contact For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make , 36V Tripping Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field, Sudhir Or The Like , 36V Closing Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Sudhir Or The Like , Digital Ammeter/Voltmeter (Programmable)For 11Kv Vcb Panels , Panel Indicators , Ammeter Selector Switch Of 11Kv Vcb , Tnc Switch Of 11Kv Vcb , Spring Charging Motor Of 11Kv Vcb Breaker , Spring Charging Motor Of 33Kv Vcb Breaker , Gears For 11Kv Vcb Of Different Make(Big) , Gears For 11Kv Vcb Of Different Make(Small) , Dc Delco Motor For 33 Kv Vcb , Dc Delco Motor For 11 Kv Vcb , Transormer Oil As Per Is For Power Transformers,Cts,Pts Etc , Distilled Water For Battery Bank , Almunium Alloy Clamps Of Sizes Like Ct,Pt,Pad,Isolator,La,T Etc For 100/200Mmsq Acsr , 33 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250 Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb,Megawin,Sudhir Or The Like , 33K Vcb Bushe Complete Assembly Confirming To Is:2099 Standard , 33Kv /11 Kv Bushes Of Power Transformers Complete Assembly Confirming To Is:2099 Standards , 11Kv/ Lv Bushes Along With Bush Rods Of Auxillary Transformers Complete Confirming To Is: 2099 Standards , 33Kv P.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bush Rod , 33Kv Isolator Grovees(Knife/Tubular Type) Complete , Almunium Tubular Bus Bar As Per Rec , 11Kv G.O Set 400 Amps , 11Kv Isolator, Double Break,3-Pole, 600Amp, Horizental Mounting Type, With Earth Switch. , 11Kv Link Set,Copper Knife(50X6x450)Mm,400 Ampers, Complete With Clamps , 33Kv Link Set,Copper Knife (50X8x600)Mm,800 Ampers, Complete With Clamps Heavy Duty , 33Kv Do / Fuse Set , Distribution Panel (30V, Dc) With 1 No.10Amp. Mccb. Double Pole For Battery Incoming Supply With Dp Mcbs & Indicating Lamps Etc. , Distribution Panel (415 V, Ac) Complete With Ckt. Breakers, Indicating Lamps Etc. , Led Lamps Of Control Room Building ( 9-15 Watts) , Led Lights For Yard( 50 Watts) , Almunium Paint , Red Oxide Paint , Almunium Thimbles Of Sizes(120-600 Sqmm) , 11 Mtr Long S.T Poles (410Sp- 56) Complete With Base And Cap As Per Rec Standard And Specifications , 9 Mtr Long S.T Poles (410Sp- 33) Complete With Base And Cap As Per Rec Standard And Specifications , 13 Mtr Long S.T Poles (410Sp- 69) Complete With Base And Cap As Per Rec Standard And Specifications , 0.2 Acsr (Panther) Conductor , 0.15 Acsr (Wolf) Conductor , 0.1 Acsr (Dog) Conductor , 0.05 Acsr (Rabbit) Conductor , Fabricated Galvanised V -Type Channel Iron X-Arm,6-10 Long Ch Iron,Channel Iron Top,Angle Iron Belts, Clamps & Flat Braces Etc As Per Rec Standard For 33/11Kv Lines. , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm , 33 Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Suitable For 0.1 Acsr Conductor , P G Clamps For 200/150/100Mm Sq Acsr , 33 Kv Danger Plates With Clamps , Anticlimbing Devices With Clamps , Gal Nuts & Bolts With Washers , Earthing Complete By G I Pipe 40Mm Or G I Rod 20Mm 2.5 Mtr Long Through G I Strip As Per Rec Standard , Galvanised Stay Set With 50X8mm Stay Clamps,Guy Insulator,Anchor Plat(300X300x8)Mm,Nuts/Bolts ,Turn Buckle,1.8 Mt Long 20Mm Dia Sold Gs Stay Rod & 7/4.0Mm Dia Gi Std Wire Complete , Guard Netting As Per Rec Standard , Galvanised Spiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard , Porceline 70 Kn Disc Insulator , Porceline 45 Kn Disc Insulator , Porceline 33Kv Insulators (10 Kn) , 33Kv G.I Pins With All Accessories Weighing 2700 Gms , 33Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , 11Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , Electrical Insulating Rubber Mat 6Mm Thickness(1Mrx2mtr). , 63 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , 100 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , Digital Three Phase Voltmeter , Porceline 11Kv Insulators , 11 Kv G.I Pins With All Accessories , Coper Bus Bar , Drill Bilts Of Sizes 3/4 And 1 , Hexa Blade , Round Hexa Blade , Welding Rods , Bush Rods For 10Mva, 6.3 Mva , Monoplastic Tape Rolls , 11Kv Pannel Hrc Fuses , Ac/Dc Mccb Of Different Ratings , Oil Temperature Indicator Of Reputed Make For 33/11-6.6Kv Power Transformers , Winding Temperature Indicator Of Reputed Makefor 33/11-6.6Kv Power Transformers , Standard Quality Silica Gel For Various Capacity 33/11Kv Power Transformers , Breaker Mechanism Of Reputed Make , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Sauitable For 0.15/0.2Acsr , 2.5 Sqmm 12 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 33Kv Grade, 1 Core Heat Shrinkable Jointing Kit, Including Required Size Of Lugs/Thimbles, As Per Relevent Is Specification 7098 (Part-Ii) 3M/ Raychem Suitable For 630/400/300Sqmm , Buchholz Relay For 33/11-6.6Kv Transformer Protection , Twin Bimettalic Clamps Aaac Equivalent 8 Bolt Type With Four Outputs As Per Relevant Is Standard Suitable For 01/0.2Acsr , Ht Tape Roll As Per Is Standard With Latest Ammendments , Indication Lamps Suitable For 33/11Kv Panel Board Ike Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir / Pascal/Hartek Make , Monoplast Tape As Per Is Standard With Latest Ammendments , Lt Insulation Tape As Per Is Standard With Latest Ammendments , Old Sarees , Earthing Electrodes As Per Is Standard With Latest Ammendments , 11Kv Auxillary Relays. , Al Alloy Tension Fittings Suitable For 50/100/150/200 Sqmm Acsr As Per Rec , Almunium Folded Ladder , Bus Bar Type Clamp For Connecting Ic Cable Outdoor , Water/Snow Resistant Shoes (Tsf Make Or Any Equivalent Brand) , Rain Coat Long Size Over Coat Type (Size 4Xl) , Umberlla Big Size , Safety/ Industrial Helmet With Straps Isi Mark, With Head Lamp Bracket And Detachable And Interchangeable Led Headlamp Alongwith Charger/Charging Facility(Color:- White , Blue And Yellow ) , Chainsaw Cutter Heavy Duty 1800-2500 W , Chainsaw Cutter Heavy Duty (Portable) 1000-1500W , Searchlight Heavyduty (Eveready, Panasonic/Philips Or Equivalent) , Heat/Flame Gun Metallic For Cable Kit Shrinking With Portable Butane Gas Can 225G Of 01No. , Butane Gas Cartridges/Canisters, Refill Fuel For Welding Torch, 225G , Electric Heat Gun For Cable Kit Shrinking 1000-200 Watt , Heavy Duty Tool Kit (Flat/Round Spanner Set, Plier, Screw Driver Set, Wire/Cutter/Striper, File With Torque Spanners Set Etc Complete Set) , Al. Ladder Foldable 2X20 Ft. Telescopic Portable Ladder , Digital Megger 5 Kv , Digital Megger 2.5 Kv , Cork Sheet 4Mm , 2V Battery 100Ah Vrla Type Of Standard Make , 2V Battery 200Ah Vrla Type Of Standard Make , 12V Battery 200Ah Lead Acid Type Of Standard Make , 33 Kv Current Transformer Outgoing/Incomer (33 Kv, 1Φ, Multi Ratio Multi Core 600-300/1A, Indoor Type) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted At Pahalgam , 11 Kv Current Transformer Outgoing (11 Kv, 1Φ, Multi Ratio Multi Core 200-400/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted (Pahalgam) , 11 Kv Current Transformer Incommer (11 Kv, 1Φ, Multi Ratio Multi Core 900-600/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station (Pahalgam) , 33 Kv Single Core Indoor Cable Kit ( Plug In Tremination Type And Screened Seperable Connectors ) For 400 Mmsq Cable For Gis Compatible Substaion (Brand:- Euromold, Nexans, Raychem Etc) , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 33Kv 1Corex400nmsq,Nndia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 11Kv 1Corex 400Mmsq,Ins Dia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Inner Core Plug In Termination Kit To Suit Size-3-Lcx630mmsq 12/20(24Kv) installation Dia: 34.0-45.06 Complete Set With All Accessories Per Set Of 3Nos Of Standard Make Gis Compatible Substation , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,630 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 11Kv 3 Core Cable Jointing Kit Of Sizes 185/240/300/400 Sqmm , 11Kv 1 Core Cable Jointing Kit Of Sizes 185/240/300/400/630 Sqmm , ⁠630 Mmsq Hydrolyic Crimping Tool , ⁠Electric Grinder 700 To 1000 W Of Standard Make , Electric Digital Welding Machines (Portable Of 100 - 250 Amps , 11Kv Cable Jointing Kit , Oil Pump Manual Of Standard Make For Transformers , Foam Spray Sealant Tins Of 450Ml , Vaseline/Grease , 11Kv Cts Of Different Ratios And Make Like Electricfield, Pasxcal, Sudhir, Stelmac Etc.) , T Clamps For Acsr 200Mmsq , Retaining Pins, Lock Nuts Of Sizes, External Retaining Rings(Rotor Clips, E Clips, C Clipso/S, Split Pins/Cotter Pins O/S , Single Phase 1 Hp Water Motor Of Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 39.37 Lakh
Boards / Undertakings / PSU No of Bidders 5
36.
Agriculture #11180321 Technical Bid
Tender for Supply Of The Electric Miscellenious Material , Empire Tape 1 , P.V.C. Tape ¾ Steel Grip Make , Glass Tape Size 1 , Cotton Tape 1 , Black Insulation Tape 1 Johnson & Johnson Make , Fiber Glass Sleeve 1 Mm , 10 Mm , 18 Mm , Film Paper 7 Mile/ 10 Mile , Nomax Paper 7 Mile/ 10 Mile , Plastic Coated Leatherized Paper 7 Mile/ 10 Mile , Fiber Glass Pipe ½ X 4 To 1 X 4 , Condensor 2.5 Mfd , 3.15 Mfd , 4.0 Mfd , 6.0 Mfd , 8.0 Mfd , 10.0 Mfd , 30.0 Mfd , 36.0 Mfd , 100.00 Mfd , 120.00 Mfd , Exhaust Fan Three Phase 415 Volt, 50 Hz Isi Mark, Size-18 , Size-24 , Exhaust Fan Blade Size-15 , Size-18 , Size-24 , Auxilary Contact Block 3Ta61,220 Volt, 4No+4Nc , Auxilary Contact Block 3Ta24/28 , Heater Rod 1000 Watt 12 Long , 1500 Watt 12 Long , Petrolium Jally 50Gm Pack , Alluminium/Copper Crimpling Lugs (Dowells Make/ Svs Make) , Lug Punching Machine Upto 400 Sqmm Crimpling Dia R4 To R14 , Crimpling Die R-4 To R-14 , Phase Tester Taparia Make , C.R.C 226 , Hot Air Blower , Benzene , Insulating Plier 8 Taparia Make , Thinner Dr.Beak L1 Twenty Litre Pack , Air Dry Varnish Dr.Beak Make Elmo Luft 1A - 21 Litre Pack , Becktol Red/Grey Dr.Beak - 4 Kg Tin , Motor Connection Plate For Bbl/Ke/Siemense/Crompton Make Motor 7.5 Hp , 10 Hp , 15 Hp , 25 Hp , 40 Hp , Screw Driver Set Taparia Make , Proximettry Switch Ps 18 Dbpo 5-30 Vdc , H.B.C./Hrc Fuse Link 250Amp. Tkf 250, 660 Vac, 80 Kag G.E.Power Controls, Isi Mark , Volt Meter 144 X 144Mm, 0-600V, Ae Make , Square Type Volt Meter, 96 X 96, 0-600V , Pedistal Type annual periodical maintenance Meter 0-200 Ctr 200/5 , 0-300 Ctr 300/5 , 0-400 Ctr 400/5 , 0-600 Ctr 600/5 , Flash Mounting Digital Frequency Meter 94 X 94Mm, 45-55Hz , 144X144mm, 45-55Hz , Soldering Rod , Soldering Iron , Soldering Flux Eyre No.7 , Soldering Wire 60% + 40% , Megger Upto 1000 Volt (Hand Operated) , Megger Upto 1000 Volt (Mechanical Operated) , Bakelite Sheet 1/16 X 2 X 4 To 3/8 X 2 X 4 , Bakelite Rod 2 , Potentio-Meter Pankaj Make 500 Ohm 3 Watt , 5K Ohm 1 Watt , 600 Ohm 3 Watt , 10K Ohm 1 Watt , Diode 15K Kitron Forward , Diode 15K Kitron Reverse , Power Diodes For T.G.Set 321 Umr 100 Reverse , Power Diodes For T.G.Set 321 Umr 100 Forward , Diode 12 Hr 40/U.S.R. 120-40 Usha 40 Amp. Normal Polarity , Reverse Polarity , Brass Holder For Fibrizer 400 Hp Slipring Motor , Brass Holder For Cane Unloader Carbon Brush Size- 40 X 40 X 20 , Brass Holder For Cane Unloader Carbon Brush Size- 25 X 25 X 100 , Carbon Holder Spring For Above Holder Size- 40 X 40 X 20 , Carbon Holder Spring For Above Holder Size- 25 X 25 X 100 , Copper Carbon Brush M-15 E Quality (A) With Pig Tail 8 X 18 X 30 , 10 X 30 X 40 , 16 X 32 X 42 , Fibrizer Motor 22 X 32 X 45 , Cane Cutter Motor 20 X 40 X 50 , 25 X 25 X 40 , 25 X 25 X 50 , 1500 Kw Alternator 25 X 40 X 55 , (B) Without Pig Tail (Cane Unloader) 25 X 40 X 40 , 20 X 20 X 96/100 , 25 X 25 X 100 , ( C ) Graphited Carbon Brush With Double Pig Tail For Centrifugal Machine 12X32x45 , 10X30x40 , Copper Carbon Brush M-15 E Quality With Double Pig Tail 25 X 32 X 50 , 25 X 40 X 50 , 32.5 X 32.5 X 12.5 (Eg-224) , Copper Carbon Brush M-15 E Quality For 1500 Kw Alternator Rotor Size 25 X 40 X 55 , Carbon Holder For 15Kw Exciter Jyoti Make , Tension Spring For Above , D.C.Volt Meter 65X65, 0-100 Amp. Panel Mounting , Push Button Element Vaisno Make 1No+1Nc , Rectifier 200Amp + Base (Usha) , Semi Conductor Fuse Gsg 1000/350, 600 Volt Ac, 350Amp (Bussmann Make) , Fuse Kit Kat 20 Amp. Ee Make , Fuse Kit Kat 32 Amp. Sm-32 Ee Make , Fuse Kit Kat 63 Amp. Sm-63 Ee Make , C.T.Operated Flash Mounting annual periodical maintenance Meter 96X96mm 0-200Amp Ctr 200/5 , 0-300Amp Ctr 300/5 , 0-400Amp Ctr 400/5 , 0-500Amp Ctr 500/5 , 0-600Amp Ctr 600/5 , 0-800Amp Ctr 800/5 , 0-3000Amp Ctr 3000/5 , But Volt Meter 0-600 V , Current Transformer Ae 50/5,100/5,200/5,400/5,600/5 , Plastic Cooling Fan For Ke/Bbl/Ngef Make Motor 3Hp , 7.5Hp , 30 Hp , Flush Type Synchronius Timer 2 Delay 5-120Sec. Em 1000 Gec , Crane Duty Motor Sq Cage Duty S-4 (Crompton/Gec/Bbl/Siemense Make) All Size/Type , Squarrel Cage Induction Motor (Crompton/Gec/Bbl/Siemense Make) All Size/Type , Allumminium Bus Bar 1/4X1 1/2 , D.C.Amp.Meter 96 X 96 Mm, 0-600 Amp. , 144 X 144Mm, 0-400 Amp. , 65 X 65, 0-15 Panalmount , Digital Multimeter 3½ Digit Model 9A Mico Make , Digital Tong Tester (Clic Amp.Meter) , Digital Amp.Meter 0 To 600 Amp. , Diode 2-4 Amp. Range , Mashroom Push Button (Vaishno) Red/Green , Push Button Element 1No+1Nc 10A 500Volt , Sc Type Indicating Lamp 220 Volt Red/Green , Push Button Station Complete 1No+1Nc Element , L.C.R. Meter Htc 4070 , Synchronous Timer Gec Make Panel Mounted Consisting 2 Delayed 2 Inst.Contact Time Range 180Sec. , Timer special repair 102, Timer Range 180Sec. Ge Make , Thyristor Skkt 330/16E For Des-80 Drive C/F Machine , Digital Rpm Meter 10Vdc, 0-1500 Rpm Ae , Semi Conductor Fuse Type Ktk-R-25 For D-412 C/F Machine , Timer Model 101 Xc Supply (Al-A2), 230 Vac, 50Hz , Bus Bar Insulator For Resistance Box , Glass Fuse 2Amp To 16Amp , Slipring For 7.5Hp, 960Rpm Motor, Bore 40Mm, Length 68.5, Ring Width 12Mm , Slipring Holder Set For 7.5Hp Crompton Make Motor , Carbon Brush For Above , Shakle Insulator , Slipring For 150 Hp Motor , Slipring For Fiberizer Motor 400 Hp, Open Ring Type (Kirlosker Make) , Carbon Brush Double Pig Tale For 400 Hp Motor, Size 32 X 22 X 50, Ec Grade , Slipring For Injuction Motor 250 Hp, 960 Rpm , Carbon Brush For Above 150Hp Slipring Motor , Carbon Brush Holder Brass For Above 150Hp Slipring Motor , Copper Transformer 415 Volt To 220 Volt, 5Amp , Gi Earthing Strip 50 X 6Mm , Change Over Switch, 4 Pol, 630 Amp. (Havells Make) , M.S. Fan Cover For Motor (Kirlosker, Ngef, Siemens & Bbl Make) :- (I) 10 Hp , (Ii) 15 Hp , (Iii) 25 Hp , (Iv) 30 Hp , (V) 40 Hp , (Vi) 50 Hp , (Vii) 75 Hp , (Viii) 90 Hp Chief Engineer
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 5
Uttarakhand View Result →
39.
Power #11176094 Price Bid
Tender for Supply Of Electrical Items And Stores Hardware Items For Sub-Transmission Division-Ii, Jpdcl, Jammmu For The Year 2026-27 , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Termination Connector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks. A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocb Bicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocb Crompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , J) Male Contact For Ocb Mei Make (With Silver Coating) , K) Female Contact For 11 Kv Ocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kv Ocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) annual rate contract Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45....65 Hz, With Rs485 Output, Aux Voltage: 1260V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5-5 , Iii) 600/300/5-5-5 , Iv) 600/300/5-5-5 , V) 400/200/5-5 , Vi) 300/150/5-5 , Vii) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One) With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 annual periodical maintenance , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based (Abc Type) 4 Kg. , C) Power Based (Abc Type) 6 Kg. , D) Power Based (Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories , 30V, 25A Battery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( detail project report 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make, Model: 30V Dc Dcps, Smps Based Dc Power System. , Main Control Card Suitbale For Use In - Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dc Boost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 Mω (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banks Apfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/√3/110V/√3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain) , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 11Kv Pt Indoor Type Resin Cast 11 Kv/110V (3 Nos) , 11Kv Pt Draw Out Type Along With Housing 11 Kv/110V (1 Complete Set) , 11 Kv Vaccum Interrupter Type Vge4 Abb Make For Pascal Vcb , 11 Kv Vaccum Interrupter Stelmac Make , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Electricfield , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Pascal , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Stelmac , Spring Charge Motor For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Stelmac , Micom Alstrom P14n Relay With 61850 Scada Compatibale Port , Ashida Make Relay Adr 241B With 61850 Scada Compatible Port , Ashida Make Relay Adr 241A Non Scada , Ashida Realy Adr 141C , Master Trip Relay Alstrom Make , Led Indicator 36 V Dc , Ethylene Propylene Rubber (Epr) Self Amalgamating Tape 38Mmx9mtr Scapa/3M , Ampere Selector Switch , 66 Kv Disc Insulator B&S Type Polymer , 66 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , Battery Charger Automatic Float-Cum-Boost Charger Input 190-230 V Ac 1Ph, Output 30 V Dc 25 annual periodical maintenance With Full Wave Rectification, Output Float Voltage: 33.0 Vdc Output Boost Voltage: 35.0 Vdc With Test Report. , Frp Extendable Ladder Of 10M , Polywater® Powerpatch® Transformer Seal And Pilc Cable Repair Allow For The Repair Of Active Leaks In The Field , Wrist Type High Voltage Detector , Hydraulic Crimping Tool Upto 630 Sq Mm Size , Digital Earth Clamp Tester , 60 Kv Motorised Oil Bdv Kit , Switch Disconneter Fuse 160 A , Mcbs 63A , 9 Mtr. St Poles , 11 Mtr. St Poles , 13 Mtr. Poles , Gaskets Of Of All Sorts For Power Transformer , 33 Kv Frp Crossarm , Frp Channels Of (100X50x6) Mm , Frp Angles Of (65X6)Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
40.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
41.
Tourism #11175186 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Supplying And Filling In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. Moorum , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-30 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. I.Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing : In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing And Fixing Exposed Laterite Stone Of 100 Mm Thk For Dado ,Laid On Cement Mortar Paste 1:4 (1 Cement : 4 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Stone Including Rubbing Including Applying Acrylic Varnish Etc Complete. As Per Designs And The Directions Of The Engineer-In-Charge. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete. 600X 600 Mm Dark Shades , Providing And Laying Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Lakha Red , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid . Plain White Makrana Slab 25Mm Thick , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : White Makrana Marble , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete). , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 30 Cm Lx 40 Cm H X 15 Cm T , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Steel Bars & Disposal Of Unserviceable Within 50 , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. 12 Mm Cement Plaster 1 :3 ( 1 Cement : 3 Sand) , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surfaces Etc. 50 X 12 Mm , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 250 X 16X 5Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete , Providing And Applying Decorative Plastering For A Window Sorrounding, Using 1:4 Morter Mixture With Bricks Chips,Featuring A 300Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer. (The Job Involves Applying A Decorative Finish Over Underlying Structure, Incorporation Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Double Piller At The Corner (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center For Hall(Ht 2.10 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 200Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Arch Of Span Of 3Mt., Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering Ofr Cornice At Ceiling In Hall Of Ht 0.40Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Construction And Installation 6Mt Height Replica Of Shree Suptakoteswar Stumb Using Sadhahalli Grey Granite Stone With Intricate Carvings, Moulding As Per Drawing. The Structure Should Have 6Mt Ht. With 2.5 X2.5X0.70 Mt Ht At Base And Stumb Of 1.50X1.50X5.25 Mt Height At Top As Per Details Drawings And Direction By The Engineer. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A 150Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Padma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Cornice ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Adhopadma For Sajja), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Electrical Works , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 1/2 Core 70Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 70 Sq. Mm. , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(K) 12 Way (8+36), Double Door, Horizontal Type Cat B , Supplying And Fixing 40 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C -- With Cat B Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.A) 20 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.B) 25 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Requiredd) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Requireda) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredb) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(C) 6 Module (200Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredsitc Of Wall Fan,600 Mm Sweep, With All Accessories. , Supply Installation Testing And Commissioning Of 8-10 W Spot Light Cob Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supply Installation Testing And Commissioning Of W 80W Flood Light Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =600X1500(H),Lamp Base- G9, Wattage- 7X42w Max, Complete With All Accessories. , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =1200X1500(H),Lamp Base- G9, Wattage- 12X42w Max, Complete With All Accessories. , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineerincharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately). , Supply Installation Testing and Commissioning of 12W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 12W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 400Mm. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 80W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo Separate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of High Quality Multi Color Neon Flexible Light, Protection Rating : Ip65, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 12W, Cct : Rgb/Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of Aluminium Profile For Neon Flex , Supply Installation Testing and Commissioning of Dc Power Driver For The Above Lights, Power : 200W, Input : Ac 110-240V Ac, 50Hz, Output : Dc 12/24V, Protection Rating, Ip67, Surge Protection : Ll 4Kv, Le 6Kv , Supply Installation Testing and Commissioning of High Quality Dmx Decoder, Power Input : Dc 24V , Supply Installation Testing and Commissioning of Pvc Insulated Multi Core Electrical Un Armoured Flexible 5C X 0.5Sq Mm Power Cable Having Less Electrical Losses. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 5 Core Dmx Cable Comprises Twisted Pairs With Shield Support For Carrying Of Data. Dmx512 Cable Is Used For Connecting All Light Consoles That Use Dmx 512 Standard Data Transmission. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete For Both Power And Dmx. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of Ip65 I Power Connectors Having 3/4 Pole Cable Connector, Chuck Type Strain Relief, Current Rating 20 A Rms Continuous, Easy And Extremely Precise Locking System Quick Lock High Impact Materials - Long-Lasting And Reliable , Supply Installation Testing and Commissioning of Ip65 I Dmx Connectors Having 3/5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Male Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Female Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options. - 12 Nos Of 6/10A Sp Outgoing Mcbs. - 1No Of 32A Tpn Incoming Mcb. , Supply Installation Testing and Commissioning of Ip Driver Box Made Up Of Pvc / Upvc And Ivory Connectors For The Internal Terminations And External Outgoing Connecting Points, Fiber / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. , Supply Installation Testing and Commissioning of Dmx Isolator Or Splitter Provides Isolated Optical Dmx Splitter Provides 8 Outputs From A 1 Input And Input Voltage: Ac 110 To 220 V, 50 Hz, Product Features: Group 1 & Group 8 Dmx Signal Change. , Supply Installation Testing and Commissioning of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory.Usb Connection • 1024 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. , Supply Installation Testing and Commissioning of Programming Charges , Supply Installation Testing and Commissioning of Additional Accessories For Installing The Lights As Per The Final Drawing/Site Condition Consisting Of Clamps, Brackets, Angles, Conduits, Joints, Hardwares Like Fasteners, Nut & Bolts Etc., , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panel, Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 100A Tpn Mcb As Incommer And 11 Nos Of Tpn Mcb As Outgoing With 3 Numbers Of Microcontoller Based Programmable Digital Almac Timer As Directed By Engineer In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
42.
Petroleum and Natural Gas #11172751 AOC
Bids Are invited for SIEVES - GI IS Test Sieves IS 460 Sieve set of internal dia 450 mmAperture size mm 100 80 63 40 20 16 12.5 10 4.75 2.36 lid and pan , SIEVES - GI IS Test Sieves IS 460 Sieve set of internal dia 200 mmAperture size mm 10 4.75 2.36 1.18Aperture size micron 600 300 150 75 lid and pan , SIEVES - Electric Sieve Shaker with timer capable of shaking sieve size of 200 mm to 450 mm diameter , Weighing Balance - Weighing Balance Electronic Capacity 50 kg Accuracy 2 gm , Weighing Balance - Weighing Balance Electronic Capacity 02 kg Accuracy 0.1 gm , Concrete Slump Test Apparatu - Concrete Slump Test Apparatus Slump Cone Steel Plate Tamping Rod Steel Scale Scoop , Compression Testing Machine - Compression Testing Machine 2000 kN Electrically Operated , Steel Cubes - Steel Cubes 150 mm for Concrete , Density Measurement - Apparatus for Density Measurement by Sand Replacement Method , Core Cutting Testing Apparatus - Core Cutting Testing Apparatus for Density Measurement 2 cores , Digital Moisture Meter , Thermometer - Thermometer 0 deg C to 100 deg C , Graduated Measuring Cylinder - Graduated Measuring Cylinder Each of 100 ml 250 ml 500 ml 1000 ml , Enamel Trays - Enamel Trays mm Approx 600 X 450 X 50 , Enamel Trays - Enamel Trays mm Approx 450 X 300 X 40 , Enamel Trays - Enamel Trays mm Approx 300 X 250 X 40 , Enamel Trays - Enamel Trays mm Approx Circular 250 , Vernier Calliper - Vernier Calliper Least Count 0.1 mm , Micro meter Screw Gauge Least Count 0.02 mm - Micrometer Screw Gauge Least Count 0.02 mm , Wire Gauge , Steel Tape - Steel Tape 30 m , Steel Tape - Steel Tape 15 m , Steel Tape - Steel Tape 5 m , Steel Tape - Steel Tape 3 m , Steel Scale - Steel Scale 1000 mm , Steel Scale - Steel Scale 30 mm , Steel Tape - Steel Tape 50 m , Allen key mm and inch , Electrical Testeing Rod - Electrical Tester , Megger , Auto Digital AC Clamp Meter , Dial Indicator for Pump and Motor Alignment , Vibration Tester , Photometer or Lux Meter , Stopwatch , Elco Meter , Roughness Meter , Lazer Distance Meter , Dew Point Measuring Instrument , Spirit Level , Plumb Bob , Screwdrivers , Handheld Mirror , Seam Paper , Long Nylon and Cotton Thread 200 M Long , Magnifying Glass , Ball Peen Hammer , Tool Box , Infrared Thermometer Gun - Infrared Thermometer Gun upto 300 degree Centigrade , Autolevel Total Quantity : 96
Contract Date: Ref. Documents Contract Value : 4.71 Lakh
Boards / Undertakings / PSU No of Bidders 7
Uttar Pradesh View Result →
44.
Housing Urban and Rular Development #11162283 AOC
Providing the manpower for electrical preventive and breakdown maintenance Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033for the period of 12 months.- 1 Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033 2 Skill Electrician: 03 Nos per day 3 Semi-Skill Electrician: 03 Nos per day 4 Un-Skill Electrician: 02 Nos. per day 5 Semi-Skill (Lift Operatror cum Attendent): 02 Nos. per day 6 SCOPE OF WORK:-1. The Scope of maintenance of electrical installation includes Routine, Preventive and Corrective Maintenance of L.T. Distribution lines to each floor of all the buildings/ blocks, entire wirings, BDB, PDB, VTPN, LT panels, Feeder Pillar Box, power & distribution cables, fittings & fixtures, Switch Boards, Power and Computer Points, Power outlet of all sorts of Air-conditioning Systems,resetting/ Switching off of Fire detection system during normal operation/ malfunctioning etc., Operation, configuration & repair / replacement of Timers for AC / Compound light, Compound Lighting including high mast, all glow sign and metal sign boards in the campus, Electrical Installations/ distribution up to Switch Board/ Panel of Lift Machine Room & Pump Room and / or Kiosk of Pump for Water Supply system, in the premises of above mentioned site. 7 2. Cleaning & checking of all the fittings & fixtures, Panels, TPN & SPN DBs, SFUs & other Electrical Installations, as well as the Compound Light installations in a regular interval to keep them in a tip-top condition at the cost of the agency and the same must be recorded in log book.3. The checking & repairing of the different types of light fittings, ceiling fans, exhaust fans etc. has to be done by the agency at his own cost (except rewinding of ceiling fans and exhaust fans) including dismantling and re-fixing of the same. (Major materials to be supplied by department). Especially, all the ceiling fans of entire worksite are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut etc. to prevent unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency. Split Pin, once taken out from the installation should not be re-used under any circumstances. Required number of Split Pin and Jam nut should be provided by the agency at their own cost. Building wise Fan register should be maintained as per Performa provided by the department, wherein each and every details of checking, replacement of spares, repairing etc. should be recorded against individual fan and every record should be signed by the attending Electrician / responsible person of the agency, duly countersigned by the concerned J.E. and A.E. 8 4. Measuring of various electrical parameters e.g. Current, Voltage, Temperature of different L.T. panel board, BDBs, Main switches etc., test of Insulation Resistance, Earth Resistance etc. are to be carried out every month and test results are to be recorded in Log book (preventive maintenance). Thermal Imaging Scanner should be used for measuring temperature of electrical equipment regularly to find out any abnormalities and printout of thermal image with date and time stamp should be provided to the concerned J.E. and A.E. In case, any abnormal reading is noticed, the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions in consultation with concerned AE&JE. Thermal image should also be taken after rectification. The engaged agency will supervision overall maintenance works and examine Logbooks for any abnormality and sign the Logbook accordingly5. Switching On/Off of the common service lighting e.g. compound, corridors, staircases etc. and AC machines, Light, Fan etc in closed room like Library, Store, OPD, OT or these are not run beyond Office hours or off day will be the responsibility of the agency. 6.Cleaning of Sub-station rooms,LT Panel rooms,operation of HT switch gear & resetting the protective rekeys in case of any fault occurred will be the responsoibilty by the agency . 9 7. Operation of DG sets & checking and maintenance of AMF panel, Checking of Battery, checking of fuel level of DG Set, Lubricating oil etc, carrying & pouring of Fuel if necessary and maintaining separate log book for DG Set as per given Proforma. For Operation of DG Sets, experienced and skilled operator should be provided8.Llift operation cum attendent including regular cleaning of lifts etc as per direction of EIC.9. Regular dusting and cleaning of fire detection sensors and others parts including reset of fire alarms. 10 TERMS & CONDITIONS:-1. The agency has to depute manpower as directed by the EIC carrying out the maintenance work smoothly with due regard to the safety.Category of Staff:- i) Skilled Electrician --03 (Three) Nos per day ii) Semi-Skill Electrician--03(Three) Nos. per day iii) Un-Skill Electrician: 02 Nos. per dayiv) Semi-Skill (Lift Operatror cum Attendent): 02 Nos per day 11 2. The Maintenance Personnel, deputed by the agency havingvalid Voter Identity/ Adhaar Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Category of Maintenance Personnel Mandatory Requirementa. Skilled Electrician Having Electrical/ Workman Permit i(b), ii & iv issued by Directorate of Electricity, West Bengal.b. Semi-Skilled Electrician Workman Permit i(b) and (ii) issued by Directorate of Electricity, West Bengal.c. Un-skilled Personnel/ Helper Basic knowledge of Electrical works.Also the Superviser of the company should have valid SCC Parts 1,2,3,4,5,6A,7A,7B ,9,11,12. 12 3. Agency must have to submit mandatorily the list of staff mentioning their Name, contact Mobile No., category, along with photo copy Valid Workman Permit, proper identity and address proof etc, in writing to the concerned JE & AE before commencing the work. All the photocopy should be attested and authenticated by the Agency.4) The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the Maintenance Staffs deployed including substitutes.They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE.5) The agency will maintain shift wise attendance register at call center to record the attendance of the staffs on duty which will be authenticated/ verified by the concerned Junior Engineer/ Officer- in-charge. 13 6) The agency shall have to prepare a Duty Roster of the Maintenance Staffs at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE and one copy should be available at the call centre.7)The agency will have to provide proper uniform for his maintenance staff at his own cost and clour of the dress will be decided by the EIC. No staff will be allowed for performing duty without proper uniform. 8) The agency, and all the electricians deputed at worksite must have Mobile Nos. and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay. 14 9) The agency has to provide one GPS activated smart phone dedicated for call center. The cost of the handset and running cost i.e. phone bills have to be borne by the agency. No claim of payment against any telephone bill will be entertained by this department.10) The agency should have a close watch on the attendance of the Maintenance Staffs. In case of absence of any Maintenance Staffs, the agency shall have to arrange for suitable alternative within an Hour, failing which, the charges for that day will be deducted from the bill of the agency on pro-rata basis.The Executive Engineer,Electrical Constrution Division ,P.W.D. reserves the right to terminate the contract in case of absence of Maintenance Staffs for more than three consecutive days, without showing further reason. 15 11) In case of any Accident and or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. Minimum wages as per existing Labor Act should be paid to the Electrician(s) and Helper(s)12) The agency shall have to provide 500V Megger, Digital Multi meter, Earth tester and all other requisite tools and tackles sufficient for checking, testing and recording of health of all electrical installations. Other tools & tackles e.g. Crimping Machine, Line Tester, Screw Driver, Pliers, Stripper, Sockets of some common sizes etc. should also be available at site, in sufficient quantities, free of cost, under disposal of their maintenance staff.Deployed employee by the agency should have sufficient knowledge to operate The Thermal imaging Scanner or to be used by the direction of Assistant Engineer/ Junior Engineer.13) The space for sitting accommodation for the staffs of the agency inside worksite premises will be provided by the competent authority. 16 14) All the maintenance staff of the contractor should have proper & constant vigilance and check that, there is no sign of heating-up, burning smell, discoloration or sparking at any of BDBs, panel boards, rising main etc. due to overloading or loose termination. Care should be taken to check any highly unbalance in loading at any point.15) In case of power failure or development of any unfavorable situation the agency will have to communicate with the concerned Power Supply Company authority and extend help or cooperation to said authority in restoration of power supply. Meanwhile the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supplies at important locations by monitoring and/ or restricting electrical loads in consultation with the concerned Junior Engineers & Assistant Engineer.16) Routine checking and preventive maintenance and breakdown maintenanceof the electrical installations has to be carried out by the agency maintaining a register under signature of respective Junior Engineer and Assistant Engineer with a view to ensure uninterrupted power supply within worksite campus. 17 17) Materials required as replacement during maintenance of electrical installations e.g. Lamps, SFUs, SPNDB, TPNDB, Cables etc. will be supplied by the Department for which requisition of Materials, signed by the authorized representative of the agency, should be submitted to the concerned JE (Electrical) well in advance. A separate material stock register should be maintained by the agency where entries related to Issue, Consumption & present stock position of Materials should be made. However auxiliary items like fuse wires, screws, nuts, bolts, washers, insulating tape, Split pins of Ceiling Fans, dusters etc. will have to be supplied by the agency at his/ their own expense.18) The agency shall have to deposit all dismantled unserviceable materials such as fused lamps, defective condensers, starters, and timers, MCBs etc. to the concerned Section Office or any other locations within worksite premises by the agency by its own laborers / arrangements / tools and tackles as per the direction of the Assistant Engineer/ JE concerned. Fresh materials will be issued against respective defective materials. No materials should be taken out of the maintenance site without the permission and necessary challan of the site-in-charge/JE 18 19) Any major shut down or fault should be brought to the notice of JE/AE immediately in writing and over telephone for further course of action. The agency will also have to attend emergency calls immediately at the site with staff, tools etc. on demand. 19 20) In case of any breakdown caused by cable fault etc., if situation demands the agency will have to restore the power supply temporarily either with the materials available with this department or arranging the same temporarily and safely at his own cost till completion of original restoration work.21) Building wise Log book is to be maintained for Preventive Maintenance & Cleaning and Corrective Maintenance of Electrical equipment except Fan as per direction of E.I.C. Separate Building wise Register is to be maintained for Ceiling Fans. The daily record of the Log book is to be signed by the responsible person and verified & signed by concerned JE & AE and photocopy of the same should be sent to the Executive Engineer concerned through proper channel at the time of submission of bills. The Logbooks should be available at Call center and should be produced on demand. 20 21) The agency should be responsible for any damage in the installation due to mishandling or mal- operation by its staff and shall be liable for rectification / replacement, as the case may be, of the damaged installation/ equipment within time frame to be fixed by concerned A.E., failing which the said rectification/ replacement of affected equipment/ installation would be executed by external agency and the cost thereof would be recovered from the bill and the accused staff should be replaced immediately.22) Bills should be submitted quarterly with the certification of satisfactory performance of the concerned JE and AE. Photocopy of Logbook and Attendance Register should also accompany the Bill. Payment should be made as per PWD norms. 21 23) Any fault of electrical installations starting from LT supply end (except the installations of Power Supply Company) to light, fan, call bell, plug points etc. i.e. LT cables and all sub-panels, distribution boards, main switches, earthing attachments, compound lights etc. has to be detected, attended and restored by the agency by its own man power with the help of the materials(cables, main switches, DBs, wires, HRC fuses etc.) available from this department or as per the terms & conditions of this contract. 24) If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions causing inconveniences to public service, is subject to unilateral penalty, be it detected on the spot or thereafter (even after payment). This Department also reserves the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge for any shortfall in observing above T&C. In that case, the above- said contract may be terminated without issuing any notice and Stringent & punishable action may be taken against the contractor. 22 25) The technitian of the agency should capable of Casing -caping /rigid conduit wiring to overcome the emergent situation .25) The contract may be terminated with one months’ notice on either side (both agency and tender awarding authority) . 26) At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .27) Any upcoming / Ongoing project, which will be completed within stipulated period of Maintenance contract, automatically will come under maintenance contract .28) All the log-books should be available at the call center and to be produced to the Office of the AE/ JE on demand. 29) This Maintenance contract covers all the buildings, blocks, outdoor electrical gadgets within the premises ofTechnician Studio, Kolkata-700033 23 TERMS & CONDITIONS FOR OPERATION OF LIFTS:- 24 1. The agency has to depute manpower as directed by the EIC carrying out the lift operation smoothly with due regard to the safety.Category of Staff:- Semi-Skill (Lift Operatror cum Attendent): 02 Nos. 25 2. Day to day Attendent -cum -operation of passenger lift foras directed by the EIC.3. The lift operator/attendant should have a sound knowledge with valid lift operator license issued by the Licensing Board, Govt. of West Bengal.4. The operator/attendant should be obliging dutiful and polite to all while on duty. In case any irregularities of duty or complain against the operator/attendant if noticed, would be withdrawn forthwith and shall be replaced by new operator.5. The report is to be submitted periodically about the working of lift incl. all safety devices and Governor to the concerned JE/AE. 26 6. Agency must have to produce the list of the staff mentioning their Name, contact Mobile No.in writing with proper identity and address proof & their Valid lift operator license issued by the Licensing Board, Govt. of West Bengal along with photo copy to the concerned JE & AE before commencing the work. This should be treated as mandatory.7. The agency will have to provide proper dress for his staff and color of the dress will be decided by this department. No staff will be allowed for performing duty without proper dress.8. The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the operation Staffs deployed including substitutes. They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE 27 9. The agency shall have to prepare a Duty Roster of the operation Staff at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE.10. The agency must have separate contact telephone numbers with Mobile Nos. for his office and Supervisor deputed at worksite so that the agency may be communicated in case of any urgency and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay.11. The lift enclosure to be kept clean (not sweepers works) regularly by the operator 28 12. The operational work of the lift is to be supervised directly under the supervision of technical staff of the contractors under the direct control of JE/AE concerned. The contractor shall be responsible for any damage to the lift due to mishandling; loss will be recovered from the contractors bill as per direction of EIC.13. The Log Book recording regarding functioning and breakdown of the lift is to be maintained at site by the contractor under supervisions of JE concerned. If any kind of trouble arises, it should be brought to the notice of JE, AE concerned immediately. The JE/AE would put their signature on log book making note on performance. 29 14. In case of any absence of operator, the lift is to be made operative within 2 hours by placing the new operator. In case of absence prorate deduction will be made from the contractors bill and the contract may be terminated if it exceeds 3 (three) days. In this respect Executive Engineer’s decision will be final.15. This department would not be held responsibility for any accident of the liftman on duty for any reasons. The contractor or their lift operators on duty would not claim any compensation in any shape from this department for such accident. 30 16. The Executive Engineer,Electrical ConstructionDivision, P.W.Dte. would have sole authority to cancel the contract without assigning any reason with a notice of one month only.17. Any conditional quotation offered would not be accepted.18. Any quotation offered with price variation clause would not be accepted.19. The payment will be made monthly/quarterly on submission of bill in triplicate by the agency with satisfactory report regarding performance by the concerned JE/AE. Copy of log book has to be enclosed with the bill. 31 20. Persons entrusted by the agency for operation of lift should wear photo Identity Card during duty hours.21. Documentary evidence in support of payment of minimum wages as per Labour Act to be produced to the Principal Employer i.e. Executive Engineer, Electrical Construction Division, P.W.Dte. in-charge of works.22. Rescue operation is in the scope of agency in case of exigency arises out of lifts getting stopped in between landing floors with passengers inside cage.23. No claim towards cost of uniform, PPE e.g. Hand Gloves, Mask, Goggles, protective body- ware etc. for the maintenance staffs should be entertained by this department. However, if any such equipment/ dress is available from the Hospital Authority for their statutory requirement, the same would be provided. BUT IN NO CASE IT SHOULD BE ENTERTAINED AS MANDATORY CLAIM.24.At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .
Contract Date: Mar 09, 2026 Contract Value : 14.46 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
45.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: May 22, 2026 Contract Value : 15.90 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 2.11 Lakh
Government Departments No of Bidders 11
Andhra Pradesh View Result →
50.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
TenderDetail
Loading tenders