View Bid Results For Material Handling System Tenders

We found 1010 Bid Results related to material handling system tenders. You can find Contractor details who won material handling system tenders along with contract details in Bid awards announcements section.

Filters
Stage
701
234
75
Tender Publishing Platform
148
862
State / UT
32
166
100
93
83
78
65
62
51
51
35
35
27
26
20
19
13
13
12
9
9
9
8
5
5
5
3
2
2
1
1
1
1
Contract Value
337
135
274
258
Publish Date
1
1
0
0
0
Sector
31
116
114
107
74
73
71
60
57
56
48
46
35
30
19
18
15
10
9
8
8
6
5
5
5
4
3
3
2
1
1
1
Ownership
6
572
220
124
77
16
1
Within keyword
Active filters:
Showing 1–21 of 1010 tenders matching your filters
1.
Agriculture #11498193 Technical Bid
Tender For Supply Of Instrument Spares-- 1 Instrument Spares 2 Instrumentation/ Instrument Store A/C}Ac Radiator Cleaner(Im0405) 3 {Instrumentation/ Instrument Store A/C}Air Filter Regulator (Ash Handling), Model – Sb60K‐4G‐M7D‐Rglb(Im0056)Air Filter Regulator (Ash Handling)Model – Sb60K-4G-M7D-Rglbmaximum Inlet Pressure :Matel Bowl – 17.5 Kg/Cm²Transparent Bowl – 10.5 Kg/Cm²Sec. Pressure Range – 0.87-8.75 Kg/Cm²Port – ½” Bsp 4 Instrumentation/ Instrument Store A/C}Glycerine Pressure Gauge For Seal Pressure & Vessel Pressure (Ash Handling) Type – Panel Mounting Front Dial Size – 60 Mm, Back Dial Size – 63 Mm, Coler Dial Size – 86 Mm Range – (0 To 10 Kg/Cm²)(Im0110) 5 Instrumentation/ Instrument Store A/C}Lapping Polythene For Wrapping The Instruments(Im0403) 6 {Instrumentation/ Instrument Store A/C}Low Oil Level Switch With Low Oil Level Sensor For Ct Fan- 90~240 Vac(Im0393)Low Oil Level Switch With Low Oil Level Sensor For Ct Fan,Model – Lols,Serial Number – Lols/1084/07/19,Supply – 90 ~ 240 Vac 7 Instrumentation/ Instrument Store A/C}N Type Thermocouple Duplex For Combustion Zone Length - 795 Mm Dia - 14 Mm(Im0283) 8 Instrumentation/ Instrument Store A/C}Power Cylinder For Fd Fan & Sa Fan Bypass Damper Make = Duncan Serial Number = Model Number = Pocc4765 Bore Size = Mm Stroke = Mm Maximum Pressure = 10 Bar(Im0218) 9 Instrumentation/ Instrument Store A/C}Power Cylinder For Fd Fan & Sa Fan Main Damper Make = Duncan Serial Number = Pplr12338/002 Model Number = Pocc4764 Bore Size = 125 Mm Stroke = 300 Mm Maximum Pressure = 10 Bar(Im0284) 10 Instrumentation/ Instrument Store A/C}Power Cylinder For Id Fan Suction Damper Make = Keltron (Pneumatic Actuator) Type = A0612 911294 Serial Number = 1920 2470790 Customer Tag Number = Pcd - 405(Im0286) 11 Instrumentation/ Instrument Store A/C}Quick Exhaust Valve Of Seal Pressure Make = Parker Model Number = Orb25Nb Part – 1 Size = 1/4\ Part – 2 Size = 1/4\ Part – 3 Size = 3/8\ Maximum Pressure = 150 Psi(Im0267) 12 Instrumentation/ Instrument Store A/C}Ss Connector (For Pumps) Push-In Tubing O.D : 8 Mm, Thread Size : Pt, R, Bspt 1/4, Body Material : 316 Stainless Steel, Thread Material : 316 Stainless Steel, Working Pressure : 0∼2.0Mpa / 0∼290 Psi, Working Temperature : -20∼150°C / -4∼302°F, Lock Claw : Stainless Steel (Sus), Applicable Tube : Pu / Pa / Pe / Teflon Tubing(Im0402) 13 Misc. / General Store A/C}Truck Tyre Tubemake = Apollo(Gn0005) 14 Instrumentation/ Instrument Store A/C}Vortex Flow Meters(Im0119)Model – 8600Df030Sa1N1D1M5,Series – 8600,S/N – 13231309,Flange – 3” Asme 150 ( 481) 15 {Instrumentation/ Instrument Store A/C}Smart Positioner (Linear), Make – Rotork, Model – Yt-3300Lsn1521S, Explosion Proof– Non-Explosion, Ingress Protection – Type 4X, Ip66, Input Signal – 4 ~ 20Ma Dc, Operating Temp. – -30 ~ 85°C (-22 ~ 185°F), Supply Pressure – 0.14 ~ 0.7 Mpa (1.4 ~ 7 Bar)(Im0388) 16 {Instrumentation/ Instrument Store A/C}Smart Positioner (Linear), Make – Siemens, Type – Sipart Ps2 Hart Positioner, Model– 6Dr5120-0Nn00-0Aa0, Sw – 5.02.01, Hw – 1.00.03, Iw – 4~20 Ma Dc, P – 1.4 ~ 7 Bar, Max. – 100 Ma, Umax. – 35Vdc, Ta – (-30°C ~ +80°C)(Im0390) 17 Instrumentation/ Instrument Store A/C}Smart Positioner (Rotary),Make – Rotork, Model – Yt-3300 Rsn 5321S, Explosion Proof – Non-Explosion, Ingress Protection – Type 4X, Ip66, Input Signal – 4 ~ 20Ma Dc, Operating Temp. – -30 ~ 85°C (-22 ~ 185°F), Supply Pressure – 0.14 ~ 0.7 Mpa (1.4 ~ 7 Bar)(Im0389) (482) 18 Instrumentation/ Instrument Store A/C}Female Air Connector (Ss) Size – 3/8”(Im0210) 19 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector Size – ¼’’ X 8 Mm(Im0105) 20 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/2\ X 10 Mm, Make – Janatics/Festo(Im0379) 21 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/2\ X 12 Mm, Make – Janatics/Festo(Im0383) 22 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/2\ X 8 Mm, Make – Janatics/Festo(Im0375) 23 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/4\ X 10 Mm, Make – Janatics/Festo(Im0377) 24 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/4\ X 12 Mm, Make – Janatics/Festo(Im0381 25 {Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/8\ X 10 Mm, Make – Janatics/Festo(Im0376) 26 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/8\ X 12 Mm, Make – Janatics/Festo(Im0380) 27 {Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 1/8\ X 8 Mm, Make – Janatics/Festo(Im0373) 28 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 3/8\ X 10 Mm, Make – Janatics/Festo(Im0378) 29 Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 3/8\ X 12 Mm, Make – Janatics/Festo(Im0382) 30 {Instrumentation/ Instrument Store A/C}Pu Tube Female Connector, Size – 3/8\ X 8 Mm, Make – Janatics/Festo(Im0374) 31 {Instrumentation/ Instrument Store A/C}Pu Tube Flow Control Valve, Size – ¼’’ X 10 Mm, Type – Exhaust Control, Make – Janatics/Festo(Im0371) 32 Instrumentation/ Instrument Store A/C}Pu Tube Flow Control Valve, Size – ¼’’ X 12 Mm, Type – Exhaust Control, Make – Janatics/Festo(Im0372) 33 Instrumentation/ Instrument Store A/C}Pu Tube Flow Control Valve, Size – ¼’’ X 8 Mm, Type – Exhaust Control, Make – Janatics/Festo(Im0370) 34 Instrumentation/ Instrument Store A/C}Pu Tube Male Branch Tee- 1/4\ * 10 Mm(Im0395) 35 Instrumentation/ Instrument Store A/C}Pu Tube Male Branch Tee- 1/4\ * 12 Mm(Im0396) 36 Instrumentation/ Instrument Store A/C}Pu Tube Male Branch Tee- 1/4\ * 8 Mm(Im0394) 37 Instrumentation/ Instrument Store A/C}Pu Tube Male Connector Size – ½ ’’ X 8 Mm Make – Janatics/Festo(Im0207) 38 Instrumentation/ Instrument Store A/C}Pu Tube Male Connector, Size – 1/8\ X 8 Mm, Make – Janatics/Festo(Im0384) 39 Building Material/Building Store}Pu Tube Male Connector, Size – 3/8\ X 10 Mm, Make – Janatics/Festo(Im0386) 40 {Instrumentation/ Instrument Store A/C}Pu Tube Male Connector, Size – 3/8\ X 12 Mm, Make – Janatics/Festo(Im0387) 41 {Instrumentation/ Instrument Store A/C}Pu Tube Male Connector, Size – 3/8\ X 8 Mm, Make – Janatics/Festo(Im0385) 42 {Instrumentation/ Instrument Store A/C}Pu Tube Od – 12 Mm Make – Janatics/Festo(Im0205) 43 Instrumentation/ Instrument Store A/C}Ss Tube Diameters: Od – 8 Mm Id – 6 Mm Thickness – 2 Mm(Im0209) 44 Instrumentation/ Instrument Store A/C}Union For 8 Mm Ss-Tube(Im0211) (484) 45 Mechanical Spares}Rubber Seal Kit For Actuator Sr 150(Sp0047)Model No. – R050 46 {Mechanical Spares}Rubber Seal Kit For Actuator Sr 200/250,Model No.R090,Make: Uniflow Control Instrument(Sp0045)Model No. – R090 47 Mechanical Spares}Rubber Seal Kit For Actuator Sr 300(Sp0048)Model No. – R130 48 Mechanical Spares}Rubber Seal Kit For Actuator Sr 50/80,Model No.R012,Make: Uniflow Control Instrument(Sp0044)Model No. – R012 (485) 49 {Instrumentation/ Instrument Store A/C}Donnelly Chute Level Sensor Holder Model – Ki-3015-Bpkg/Ni Make – Ikm Sr-633 Type – Pnp (Conductive) Vtg – 10 To 36 Vdc(Im0229) 50 Instrumentation/ Instrument Store A/C}Lift Sensor Controller Make – Masibus Model – Lc5296H-C-U1-1-N-5 Input Vtg – 85-256 Vac/100-300 Vdc Output – 4 To 20 Ma Range – 0 To 100 % Sr. No. – 2001H1 3896(Im0040) 51 Instrumentation/ Instrument Store A/C}Lift Sensor Make – Banner Model – S18Uia Vtg – (+10 To 30 Vdc) O/P Amp – 4 To 20 Ma(Im0336) 52 Instrumentation/ Instrument Store A/C}Pressure Switch For Fibrizer Oil Pump, Range – 0∼4 Bar(Im0401) (486) 53 Instrumentation/ Instrument Store A/C}Cable For Feedback Sensor Make – Energy-Tech Part Code – Ete-C-0302(Im0327)We Require Cable Length - 05 Mtr 54 {Instrumentation/ Instrument Store A/C}Current Transducer(Im0189)Part Code – Ete-C- 0307 55 {Instrumentation/ Instrument Store A/C}Electro Pneumatic Positioner P-90 Make – Energy-Tech Part Code – Ete-C-0306-Irt(Im0324) 56 Instrumentation/ Instrument Store A/C}Male-Female Connector For Feedback Sensor Make – Energy-Tech Part Code – Ete-C-0301-1(Im0328) 57 {Centrifugal Store A/C}Pid Controller For Centrifugal Machine Model : Btc-9300 Make : Rosh Part Code-Ete-C-0305-Rt(Sp0347) 58 Instrumentation/ Instrument Store A/C}Solenoid Valve For Batch Machine & Refinery, Model Number – 5/2 Poppet Valve K‐412‐D(Im0005)Pressure – 10 Bar,Size – ¼” Bsp (F),Supply – 24Vdc 59 {Instrumentation/ Instrument Store A/C}Solenoid Valve For Batch Machine & Refinery, Model Number – 5/2 Poppet Valve K‐412‐S(Im0091)Pressure – 10 Bar,Size – ¼” Bsp (F),Supply – 24Vdc 60 Instrumentation/ Instrument Store A/C}Solenoid Valve Gang Make – Energy-Tech Part Code – Ete-C-0303(Im0329) 61 Instrumentation/ Instrument Store A/C}Valve Position Feedback Sensor Make – Energy-Tech Part Code – Ete-C-0301(Im0326)(490) 62 Instrumentation/ Instrument Store A/C}Bag – Clamp Rubber Pad & Clamp Make – Hi-Tech Size – (260X40X20) Mm(Im0323) 63 Instrumentation/ Instrument Store A/C}Miniature Level Switch(Im0190)Supply - 24Vdc (491) 64 Mechanical Spares}Rubber Seal Kit For Actuator Sr 100/125(Sp0196)Model No. – R025 (492) 65 Instrumentation/ Instrument Store A/C}Electromagnetic Flow Meter 100Mm(4\), Make:Upc,Model: Upcs Mag 110 ,230Vac,O/P 4.20Ma(Im0244) (493) 66 Instrumentation/ Instrument Store A/C}Compound Gauge Model – En837-1 Dial Size – 6\ (150 Mm) Range – (-760 Mmhg To 1.5 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0048) 67 {Instrumentation/ Instrument Store A/C}Glycerine Pressure Gauge Model – En837-1 Type – Glycerine Filled (Bottom Entry) Dial Size – 6” (150 Mm) Range – (0 To 10 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0015) 68 Instrumentation/ Instrument Store A/C}Glycerine Pressure Gauge Model – En837-1 Type – Glycerine Filled (Bottom Entry) Dial Size – 6” (150 Mm) Range – (0 To 16 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0016) 69 Instrumentation/ Instrument Store A/C}Pressure Gauge Dial Size 6\,(0-100)Kg/Cm2(Im0009)Pressure Gauge,Model – En837-1,Dial Size – 6” (150 Mm),Range – (0 To 100 Kg/Cm²),Thread – ½” Npt (Bottom Entry) 70 {Instrumentation/ Instrument Store A/C}Pressure Gauge Model – En837-1 Dial Size – 6” (150 Mm) Range – (0 To 04 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0006) 71 Instrumentation/ Instrument Store A/C}Pressure Gauge Model – En837-1 Dial Size – 6” (150 Mm) Range – (0 To 06 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0007) 72 {Instrumentation/ Instrument Store A/C}Pressure Gauge Model – En837-1 Dial Size – 6” (150 Mm) Range – (0 To 10 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0018) 73 Instrumentation/ Instrument Store A/C}Pressure Gauge Model – En837-1 Dial Size – 6” (150 Mm) Range – (0 To 16 Kg/Cm²) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0013) 74 Instrumentation/ Instrument Store A/C}Vaccume Gauge Model – En837-1 Dial Size – 6” (150 Mm) Range – (-760 To 0 Mmhg) Make – Mass Thread – ½” Npt (Bottom Entry)(Im0049) (495) 75 Instrumentation/ Instrument Store A/C}Brass Filter For Air Filter Regulator Make – Janatics Model – Frc 136134 Max Press – 10 Bar Port Conn – G ¼” Note – We Don’T Want Complete Afr, We Need Only Brass Filter Of It.(Im0050) 76 Instrumentation/ Instrument Store A/C}Capillary Level Transmitter(Im0113)Model – 2051Cd3A22A1As234M5D4Q4,Serial Number – 08790278,Supply – 10.5 To 42.5 Vdc,Max. W.P. – 285 Psi/19.7 Bar,Cal. – 0 To 10000 Mmh2O,Flange Size – 04” (150 Mm) 77 Instrumentation/ Instrument Store A/C}Coil For Above Sov 24Vdc Make : Rotex,Model -Ip67-Cert,Klpl/Btg/16/05-26(Im0225) 78 Instrumentation/ Instrument Store A/C}Conductivity Sensor Transmitter For Condensate Conductivity Panel. With Sensor Cablemake – Teledyne Analytical Instruments Model – Lxt 330 Part – Lxt 330-10-210-00X Sr. No. – 191643-07 Type – Do Power – 100-240 Vac. 50/60 Hz (4W) Relays – 10A-250 Vac 5 A-30 Vdc(Im0263) 79 Instrumentation/ Instrument Store A/C}Deficator Valve, Valve Specifications : Make – Dembla Valves Ltd. (India), Tag No. – 03.Fcv.140.01, Sr. No. – V2028100-18, Size – 40 Mm, Type – V. Ball, Rating – Ansi-150, Series – 8200Fv, Trim – V. Ball/Eq, Cv – 75Usgpm, Body Moc – Wcb, Ball/Disc Moc – Cf8M, Seat Moc – Ptfe, Air To – Open, Act. Model – Rnpo65Sr40Ca1Gd, Stroke – 0-90, Supply Pressure – 04 Kg/Cm², ^P Shut – 2.026 Kg/Cm², Actuator Specifications : Make – Rotex, Model – Qtf63E-6, Sr.No. – So18202167/02, Max Press. – 8 Bar, Seal – Nbr, Temp. – (-20 To +80) Note:– (Use In Accordance With Rotex Atex Manual) Complete Set Contains Actuator + Gear System + Valve(Im0261) 80 Instrumentation/ Instrument Store A/C}Dial Gauge For Air Filter Regulator Make – Janatics Model – Frc 136134 Max Press – 10 Bar Port Conn – G ¼” Note – We Don’T Want Complete Afr, We Need Only Dial Gauge Of It.(Im0046) 81 Instrumentation/ Instrument Store A/C}Hand Lever Valve For Batch Machine Size-1/4\ Bsp,5/2 Way(Im0392) 82 {Instrumentation/ Instrument Store A/C}Hose/Connecting Pipe For Versatile Brix Transmitter(Im0062) 83 Instrumentation/ Instrument Store A/C}Magnetic Flow Transmitter 3\(Line) Model 8705 Tsa 030C1Wob3,Max Vtg-I/P 40Vdc,O/P 05V,Max Current-I/P 0.5A,O/P 0.2A,Max Power-I/P20W,O/P-1Mvv,Supply-90-250Vac,50/60Hz,O/P 4To20Ma Pulse-10000Hz,Make : Rosemount(Im0247)Magnetic Flow Meter Line Size - 3”Sensor Specification :Make – Rosemount Mumbai India,Model – 8705Tsa030C1W0B3,Sr.No. – 13357254,Max Vtg – I/P – 40 Vdc, O/P – 05 V,Max Current – I/P – 0.5 A, O/P – 0.2 Ma,Max Power – I/P – 20 W, O/P – 01 Mw,Max Process Press @ 100°F/38°C : 285Psig/1.9 Mpa.,Display (Transmitter) Specification :Make – Rosemount Mumbai India,Model – 8732Emt1A1M4,Sr. No. – 13357255,Supply – 90 To 250 Vac, 50/60Hz,O/P – 4 To 20Ma,Pulse – 0 To 10000 Hz 84 {Instrumentation/ Instrument Store A/C}Mud Silo Cylinder Repair Kit Make – Puri Industries Cover – C.I Shell – Ss 304 Seal – Rubber(Im0346) 85 Instrumentation/ Instrument Store A/C}Pressure Transmitter Make – Rosemount Mumbai India Model No. – 2051Gp2A2B21Ab4D4M5Q4 Sr.No. – 08790240 Cal – (0 To 3 Kg/Cm²) Max. Wp – 150 Psi/10.3 Bar Supply – 10.5 To 42 Vdc O/P Hart – 4 To 20 Ma(Im0052) 86 Instrumentation/ Instrument Store A/C}Process Indicator Controllermake = Selecmodel = Pic152(Im0051) 87 Instrumentation/ Instrument Store A/C}Solenoid Valve For Versatile Brix Tx. Cylinder,Make Karma Model-52As-24 Vdc(Im0061) (498) 88 Instrumentation/ Instrument Store A/C}1 Pair X 1.0 Sqmm Shielded Armoured Cable, Make – Polytex Cable(Im0361) 89 Instrumentation/ Instrument Store A/C}1 Triad X 1.0 Sqmm Shielded Armoured Cable, Make – Polytex Cable(Im0368) 90 {Instrumentation/ Instrument Store A/C}3 Core X 2.5 Sqmm Armoured Cable, Make – Polytex Cable(Im0364) 91 Instrumentation/ Instrument Store A/C}7 Core X 1.5 Sqmm Shielded Armoured Cable, Make – Polytex Cable(Im0365) (508) Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 6
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
4.
Power #11435744 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 3808647; 3808647; Service Provider - Engaging J.C.B. Machine/Hydraulic Excavator Including Driver And Fuel Charges Complete For Different Works. , Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Up To 1.5 M. , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications : On W.B.M. @ 0.75 Kg / Sqm . , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumenwith Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications : On Bituminous Surface @ 0.50 Kg / Sqm , 4.0 Cm Premix Carpet Surfacing Including A Tack Coat With Hot Straight Straight Run Bitumen,Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete(Tack Coat To Be Paid For Separately).With Paving Asphalt Grade Vg-10 Heated And Then Mixed With Solvent At The Rate Of 70 Grms Per Kg Of Asphalt. , Providing And Laying Seal Coat Over Prepared Surface Of Road Withbitumen Heated In Bitumen Boiler Fitted With The Spray Set Sprayingusing 98 Kg Of Bitumen Of Grade Vg - 10 And Blinding Surface With0.90 Cum Of Stone Aggregate Of 6.7 Mm Size (Passing 11.2 Mm Sieveand Retained On 2.36 Mm Sieve) Per 100 Sqm Of Road Surface, Includingrolling And Finishing With Power Road Roller All Complete. , 2.5 Cm Premix Carpet Surfacing With 2.25 Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively, Including A Tack Coat With Hot Straight Run Bitumen, Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately).With Paving Asphalt Grade Vg - 10 Heated And Then Mixed With Solvent At The Rate Of 70 Grams Per Kg Of Asphalt . , Providing And Laying In Position Cement Concrete Of Specified Gradeexcluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying 60Mm Thick Faciory Made Cement Concreteinterlocking Paver Block Of M -30 Grade Made By Block Makingmachine With Strong Vibratory Compaction, Of Approved Size, Design& Shape, Laid In Required Colour And Pattern Over And Including 50Mmthick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sandetc. All Complete As Per The Direction Of Engineer-In-Charge , Taking Out Existing Cc Interlocking Paver Blocks From Footpath/ Centralverge, Including Removal Of Rubbish Etc., Disposal Of Unserviceablematerial To The Dumping Ground, For Which Payment Shall Be Madeseparately And Stacking Of Serviceable Material Within 50 Metre Leadas Per Direction Of Engineer-In-Charge , Laying Old Cement Cocrete Interlocking Paver Blocks Of Any Design/Shape Laid In Required Line, Level, Curvature, Colour And Pattern Overand Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling Thejoints With Fine Sand Etc. All Complete As Per The Direction Of Engineer_X0002_In-Charge. (Old Cc Paver Blocks Shall Be Supplied By The Departmentfree Of Cost) , Cartage Of Malwa By Tractor Trolly From Periphery Of Area Cleared Including Cost Of All Labour ,T&P Such As Loading Unloading And Cartage For Proper Completion Of Work. , Supplying And Stacking At Site 53 Mm To 22.4 Mm Size Stone Aggregate , Supplying And Stacking At Site.Moorum. , Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Specifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road / Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density . , Carriage, Laying , Spreading And Compaction Of Coal Boulders From Coal Handling Plant Of Ptpp Including Spreading In Uniform Thickness, Hand Picking, Rolling With Three Wheeled Road /Vibratory Roller 8-10 Tonne In Stages In Proper Grade. , Supplying And Filling In Plinth With Sand Under Floors, Including Watering,Ramming, Consolidating And Dressing Complete. , Providing And Applying 2.5 Mm Thick Road Marking Strips (Retro-Reflective) Of Specified Shade/ Colour Using Hot Thermoplastic Materialby Fully/ Semi Automatic Thermoplastic Paint Applicator Machine Fitted With Profile Shoe, Glass Beads Dispenser, Propane Tank Heater Andprofile Shoe Heater, Driven By Experienced Operator On Road Surfaceincluding Cost Of Material, Labour, T&P, Cleaning The Road Surface Ofall Dirt, Seals, Oil, Grease And Foreign Material Etc. Complete Asper Direction Of Engineer-In-Charge And Accordance With Applicablespecifications. , Providing And Fixing Glow Studs Of Size 100X20 Mm Made Of Heavyduty Body Shall Be Moulded Asa (Acrylic Styrene Acryloretrite ) Orhip (High Impact Polystyrene) Or Abs Having Electronically Weldedmicro- Prismatic Lens With Abrasion Resistant Coating As Approved Byengineer In Charge. The Glow Stud Shall Support A Load Of 13635 Kgtested In Accordance With Astm D4280. The Slope Of Retro- Reflectivesurface Shall Be 35 (+/-5) Degress To Base .The Reflective Panels Onboth Sides With At Least 12 Cm Of Reflective Area Up Each Side. Theluminance Intensity Should Be As Per The Specification And Shall Betested As Described In Astm I: 809 As Recommended In Bs: 873
Contract Date: Ref. Documents Contract Value : 86.83 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
5.
Health and Family Welfare #11430568 Technical Bid
Tender for Pruchase Of Surgical And Sutures Items At Govt Hospital Bundi , Surgical And Sutures , Absorbable Gelatin Sponge Ip 66, Size 80(+-10) Mm X 50 Mm X 10 Mm Should Be Sterlized. , Asepto Syringe With Transparent Bulb Sterile, 60 Ml , Blood Administration Set / Blood Transfusion Set • Sharp And Easy Piercing Spike Suitable For Blood Bags And Standard Blood Containers • Transparent Cylindrical Drip Chamber With Filter.Filter Size Should Be 200+20 Micrometer. • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Transfusion Rate • Should Conform To Is 9824(Part 3):1996 , Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches • Made Of Natural Rubber Latex, Powdered, Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards) , Disposable Sterile Surgical Rubber Gloves Size 7 Inches • Made Of Natural Rubber Latex, Powdered,,Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 7 Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards) , Disposable Sterile Surgical Rubber Gloves Size 7½ Inches • Made Of Natural Rubber Latex, Powdered, Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 7 ½ Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards , Suction Catheter, Sterile. Size: Fg 5 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 6 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 8 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 10 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 12 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 14 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 16 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 18 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 20 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Suction Catheter, Sterile. Size: Fg 22 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 8 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 3- 5 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is 11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size10 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 3- 5 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size20 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Infant Feeding Tube Size:10Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:8Fg, Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:5Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile , Sterile Disposable Perfusion Set With Airway And Needle (Adult Use) • For Gravity Feed Only • Sharp And Easy Piercing Spike With Air Vent • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing • Self Sealing Latex Bulb Which Will Also Act As An Port For Extra Medication • Efficient Roller Clamp To Control And Adjust The Fluid Rate • 21 G Needle • Should Conform To Is 12655 -4 Standard , Sterile Disposable Perfusion Set (Infusion Set) With Airway And Needle (Paediatric Use) • Burette Type Measured Volume Chamber Of 100 Ml • Drop Size Of Approx 60 Drops Per Ml • Injection Port,Latexfree, For Intermittent Medication. • Floating Auto Shut Off Valve (Latex Free) In Burette. • Soft And Kink Resistant Pvc Tubing. • Roller Controller For Flow Control • Tube Length 150 Cm • 23G Needle • Should Conform To Iso 8536-5 , Sterile Disposable Infusion Set With Microdrip (I.V.) • Microdrip Infusion Set With Drop Size Reduced To Approx 60 Drops Per Ml • Sharp And Easy Piercing Spike • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Fluid Rate • Should Conform To Is 12655 - 4 Standard , Insulin Syringe ( 40 Units) With (Fixed) 30 G Needle Shall Conform To Is 12227 , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 16G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. ) Size 18G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 20G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 22G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon/ Ptfe I.V. Cannula Without Port. Size 24G • Suitable For Paediatric & Neonatal Use • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Mucus Extractor Sterile • Clear Transparent Container • Antibacterial Filter • Soft, Kink Resistant Pvc Tubing • Tube Size 10 Fg; Length 40 Cm (Min.) • Capacity 25 Ml , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Adult) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Pediatrics) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Paper Adhesive Plaster 1 X 9.0 Mts (With Cutter) • Non Woven. • Non Allergic & Strong Adhesive But Gentle To Skin. • Painless Removal. • Porous And Breathable. Paper Adhesive Plaster Should Conform To The Standards And Test Prescribed In Applicable Is And Bp Standard. , Paper Adhesive Plaster 2 X 9.0 Mts (With Cutter) • Non Woven. • Non Allergic & Strong Adhesive But Gentle To Skin. • Painless Removal. • Porous And Breathable. Paper Adhesive Plaster Should Conform To The Standards And Test Prescribed In Applicable Is And Bp Standard. , Paper Adhesive Plaster 3 X 9.0 Mts (With Cutter) • Non Woven. • Non Allergic & Strong Adhesive But Gentle To Skin. • Painless Removal. • Porous And Breathable. Paper Adhesive Plaster Should Conform To The Standards And Test Prescribed In Applicable Is And Bp Standard. , Plaster Of Paris Bandages 15Cm X 2.7Mts / Roll Should Conform To Schedule F(Ii) Of Drug And Cosmetic Act 1940 , Plaster Of Paris Bandages 10Cm X 2.7Mts / Roll Should Conform To Schedule F(Ii) Of Drug And Cosmetic Act 1940 , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 10 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 12 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 14 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 16 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 18 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Scalp Vein Set (Disposable): Size 18G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 20G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 22G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Scalp Vein Set (Disposable): Size 24G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 2 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 5 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 10 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 20 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Surgical Blade Sterile, Size 11 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Surgical Blade Sterile, Size 15 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Surgical Blade Sterile, Size 22 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Sterile Disposable Spinal Needle For Single Use 22G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Sterile Disposable Spinal Needle For Single Use 25G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Urine Collecting Bag, Disposable 2000 Ml • Transparent Sheet • Kink Resistant Flexible Tubing Not Less Than 90 Cm In Length • Should Have Non-Return Valve • Top Drainage Outlet • Graduated Bag • Moulded Handle For Easy Handling , Double J Stent, Sterile, Both Ends Open - Size 4F, Length 16 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Double J Stent, Sterile, Both Ends Open, Size 5F, Length 20 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Double J Stent, Sterile, One End Closed - Size 4F, Length 16 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Double J Stent, Sterile, One End Closed, Size 5F, Length 20 Cm • Radio Opaque • Should Be Of Inert Material, Non- Irritant To Tissue , Endotracheal Tube, Plain - Size 2.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 3Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 3.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 4Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 4.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 5.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain With Radio-Opaque Line, Sterile, Single Use - Size 6Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 6.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 7Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 7.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 8Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Plain - Size 8.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile , Endotracheal Tube, Cuffed - Size 4Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 4.5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 6Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 6.5Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 7Mm • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 7.5 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 8 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 8.5 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 9 • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Tracheostomy Tube (Pvc), Plain, Sterile, Single Use - All Sizes • Soft Flexible Flange At For Easy Fixation • 15 Mm Connector At Terminal End Which Can Be Rotated In 360 Degree Direction • Non-Irritant • Radio-Opaque Line , Tracheostomy Tube (Pvc), Cuffed, Sterile, Single Use - All Sizes • Soft Flexible Flange At For Easy Fixation • 15 Mm Connector At Terminal End Which Can Be Rotated In 360 Degree Direction • Non-Irritant • Radio-Opaque Line • Balloon With Non Return Valve , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 24) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 28) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 32) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.5 Cmx 15 Cm Soft To Feel Fast Edges,Slightly Stretchbonding. , Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 Cmx 15 Cm Soft To Feel Fast Edges,Slightly Stretchbonding. , Sterilised Umbilical Cotton Tape Width 3 Mm, Length 75 Cm Should Conform To Schedule F(Iii) Of Drug And Cosmetic Act 1940 , Bone Wax Sterilised , Skin Graft Knife Blade (Sterile) (Disposable ) Skin Grafting Knife Blade (Sterile) Made Of Carbon Steel Or Stainless Steel Material 158 Mm Long Individually Wrapped In Wrapper Corrosion Inhibitor Paper In Single Packet,.In Packs Of 10. The Edge Must Be Sharp Enough To Cut The Skin In A Single Shave And Should Snugly Fit In The Handle Should Conform To Is 3759. 2. Skin Grafting Knife Handle (Watson Modification Of HumbyS Knife ) Stainless Steel, Ce Certified, In Which The Blade Specified In (A) Above Should Fit Snugly. Should Conform To 7980-1976. , K Wire, Length 375 Mm; 1Mm Length Of Wire Should Be Mentioned With Specification. Should Conform To Is 8261 , K Wire, Length 375 Mm;1.6Mm • Length Of Wire Should Be Mentioned With Specification. • Should Conform To Is 8261 , K Wire, Length 375 Mm; Size 1.8Mm • Length Of Wire Should Be Mentioned With Specification. •Should Conform To Is 8261 , Face Mask, Disposable • Should Be Manufactured From Non Woven Poly Prop Fabric • Should Be 3 Ply Construction • Should Have High Bacterial Filtration Efficiency • Should Be Heat Sealed To Keep 3 Layers Together • Standard Size 17.5 X9 Cm • Color Green/Blue • There Should Be A String Each At All Four Corners,Length Of String Should Be 40Cm • Nose Clip Should Be There • No Elastic Band. , Surgical Cap, Disposable (For Surgeons) • Should Be Manufactured From Non Woven Fabric. • Strip For Tying The Cap Stitched On The Back For Proper Grip On The Forhead. • Green Colour • Ultrasonically Stitched • Air Permeable/Breathable • Should Retain Skin And Hair Particle. • Strip For Tying The Cap , Surgical Cap, Disposable ( For Nurses) • Should Be Manufactured From Non Woven Fabric • Blue / Green Colour • Round Upon Wearing, With Elastic • Air Permeable / Breathable • Should Retain Skin And Hair Particles , Foldable Intra Ocular Lense With Injector (Size + 11 D To +17.5 D) Size:6Mm Optics. 12-13Mm Total Diameter 1. Made Of Foldable Acrylic (Hydrophobic) Material 2. Bi-Convex Single Piece Iol With Aspheric Optics 3. Size:6Mm Optics. 12-13Mm Total Diameter. 4. Modified C Loop Haptic 5. Iol Should Have Uv Blocking Capability 6. Iol Should Have 360°Square Edge.. 7. Foldable And Insertion By Injector With Disposable Cartridge Insertable By A Sub 2.8 Mm Incision Size Or Smaller Incision 8. Diopters- + 11 D To +17.5 D At 0.5 D Step. 9. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Foldable Intra Ocular Lense With Injector (Size + 18 D To + 24 D) Size:6Mm Optics. 12-13Mm Total Diameter 1. Made Of Foldable Acrylic (Hydrophobic) Material 2. Bi-Convex Single Piece Iol With Aspheric Optics 3. Size:6Mm Optics. 12-13Mm Total Diameter. 4. Modified C Loop Haptic/Plate Haptics 5. Iol Should Have Uv Blocking Capability 6. Iol Should Have 360°Square Edge.. 7. Foldable And Insertion By Injector With Disposable Cartridge Insertable By A Sub 2.8 Mm Incision Size Or Smaller Incision 8. Diopters- + 18 D To + 24 D At 0.5 D Step. 9. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Foldable Intra Ocular Lense With Injector (Size + 24.5 D To + 28.5 D ) Size:6Mm Optics. 12-13Mm Total Diameter 1. Made Of Foldable Acrylic (Hydrophobic) Material 2. Bi-Convex Single Piece Iol With Aspheric Optics 3. Size:6Mm Optics. 12-13Mm Total Diameter. 4. Modified C Loop Haptic 5. Iol Should Have Uv Blocking Capability 6. Iol Should Have 360°Square Edge.. 7. Foldable And Insertion By Injector With Disposable Cartridge Insertable By A Sub 2.8 Mm Incision Size Or Smaller Incision 8. Diopters- + 24.5 D To + 28.5 D At 0.5 D Step. 9. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Standard Pmma Intra Ocular Lenses (Size + 11 D To +17.5 D) • 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Biconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 11 D To +17.5 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Standard Pmma Intra Ocular Lenses (Size + 18 D To + 24 D) • 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Biconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 18 D To + 24 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Standard Pmma Intra Ocular Lenses (Size + 24.5 D To + 28.5 D ) 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Bioconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 24.5 D To + 28.5 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Disposable Sterile Surgical Rubber Gloves Size 8 Inches • Made Of Natural Rubber Latex Powdered,Without Tear,Properly Folded In A Paper • Should Conform To Is 13422 • Isi Marked/Ce Certified/Fda Approved • Colour Code Marking To Designate Size , Disposable Sterile Surgical Rubber Gloves Size 8 Inches • Made Of Natural Rubber Latex Powder Free,Without Tear,Properly Folded In A Paper • Should Conform To Is 13422 • Isi Marked/Ce Certified/Fda Approved • Colour Code Marking To Designate Size , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Extra Small. Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Small Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Medium Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Large Should Conform To Is 15354 , Pressure Monitoring Line / High Pressure Extension Line • Suitable For High Pressure Monitoring And For Connection Between Syringe Infusion Pump And Patient • Male Luer Lock At One End And Female Luer Lock At Other End ; Should Fit All Standard Equipment. Luer Lock Connectors Should Provide Secure Fitting. • Pressure Upto 800 Psi • Length 200 Cm • Sterile , Urine Collecting Bag For New Born /Paediatric Urine Collection Bag, Capacity 100Ml • Should Have Suitability For Both Male And Female Patients • Should Be Provided With Adhesive For Fixation And Good Grip With Minimal Risk Of Allergy And Injury • Capacity 100 Ml • Sterile , Umbilical Catheter (For New Born) All Sizes • Radio Opaque Line • With Female Flexible Mount • Colour Coded Connector • Open Tip Should Be Soft, Rounded, Atraumatic • Length 40 Cm , Umbilical Cord Clamp • Suitable For Clamping Umbilical Cord Of New Born • Security Lock To Prevent Accidental Opening After Clamping • Grooved Clamping Area , Absorbable Oxidized Regenerated Cellulose Net Size 2X 3 With Surgical Sponge Topical Absorbable Haemostatic Bactericidal Property , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) • Option To Use One Or Two Catheters Simultaneously • Bellow Chamber With Capacity 800 Ml • Bellow Unit With Connector • Graduated Bellow • Connecting Tube With Clamp And YConnector • Curved Needle / Trocar With Catheter • Multiperforated Catheter / Radon Drain With Radio Opaque Line • Catheter 16 Fg , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) • Option To Use One Or Two Catheters Simultaneously • Bellow Chamber With Capacity 800 Ml • Bellow Unit With Connector • Graduated Bellow • Connecting Tube With Clamp And YConnector • Curved Needle / Trocar With Catheter • Multiperforated Catheter / Radon Drain With Radio Opaque Line • Catheter 18 Fg , Bone Cement With Antibiotics,Fast And Slow Setting , Sanitary Napkin, Beltless 1. Covering - Covering Of The Absorbent Filler Shall Be Good Quality Knitted Sleeve Or Non-Woven Fabric Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet The Absorbency Requirements. The Napkins Shall Have A Non Absorbent Barrier On One Side Which Shall Have An Identifying Mark Indicating The Side Of The Barrier. 2. Absorbent Filler - The Filler Material Shall Consist Of Cellulose Pulp/ Wadding, And Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material, Etc. 3. Back Strip - A Back Strip For Sticking The Sanitary Napkin Onto The Underwear Should Be There Using Good Quality Adhesive Material. 4. Size - The Size Of Absorbent Section / Complete Sanitary Napkin Shall Be As Follows: ( In Mm) Absorbent Section Total Pad Length 210 +_ 10 230 +_ 10 Width 60 To 75 70 To 85 Thickness 8 +_ 2 5. Weight : Not More Than 10 Gm . . Instruction For Usage Should Be Mentioned On Every Packet , Sanitary Napkin, Belttype 1. Covering - Covering Of The Absorbent Filler Shall Be Good Quality Knitted Sleeve Or Non-Woven Fabric Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet The Absorbency Requirements. The Napkins Shall Have A Non Absorbent Barrier On One Side Which Shall Have An Identifying Mark Indicating The Side Of The Barrier. 2. Absorbent Filler - The Filler Material Shall Consist Of Cellulose Pulp/ Wadding, And Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material, Etc 3. Size - The Size Of Absorbent Section / Complete Sanitary Napkin Shall Be As Follows: ( In Mm) Absorbent Section Pad Length 220 +_ 10 Width 70 +_ 5 Thickness 17 +_ 3 4. Weight : 12 +_ 3 Gm 5. Pack - Six Napkins In A Pack. 6. Elastic Belt With Loops Shall Be Provided In Each Pack. 7. Absorbency: The Napkin Should Be Able To Absorb Not Less Than 30 Ml Of Normal Saline Or Coloured Water Or Test Fluid When Poured On To The Centre Of The Napkin At The Rate Of 15 Ml Per Minute. .Instruction For Usage Should Be Mentioned On Every Packet. , Oxygen Mask (Adult) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On The Mouth And Nasal Area • Friendly Soft Medical Pvc Material With Comfortable Fitting. • Aluminium Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. , Oxygen Mask (Paediatric) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On The Mouth And Nasal Area • Friendly Soft Medical Pvc Material With Comfortable Fitting. • Aluminium Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. • Mask Connector 4M , Sterile Catheter, Single Use, For Urinary Drainage(Foley Baloon Catheter), 2 Way, Size 14 • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For A Traumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30+- 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Ballon Capacity Should Be Mentioned As Per Is 11497 • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is 11497 , Nelaton - Catheter Size 14 Fg Distal End Is Close And Proximal End Has Female Colour Code Connector • Soft, Kink Resistant Medical Grade Pvc Tube • Length:40 Cm • Individually Packed In Poly And Sterile , Ecg Electrode •Reliable Trace, •High Conductivity,• Easy To Handle , Surgical Blade Sterile, Size 23 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 50 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Urethral Catheter 90 (Fg-14), Made Up Of Medical Grade Pvc , Urethral Catheter 91 (Fg-10), Made Up Of Medical Grade Pvc , Vaccum Suction Set, 2.5 Meter Length, •Suction Handle With Suction Tube •Sterile,• Pyrogenic Free, •Latex Free,• Single Use , Epidural Minipack 18G, 90 Mm, Metal Stylet For Single Use Only, •Sterile, •Epidural Catheter 20G, L 90 Cm, •6 Lateral Holes Closed End, •Borst Adapter •Epidural Catheter Flat Filter 0.2 Micro Meter •Thread Assist Guide•Lor (Loss Of Resistance) Plastic Syringe 6 Ml , Vascular Catheter 16G/5Fr, Double Lumen Length 40Cm.Usfda/ Four Digit Notified Ce Approved, Should Have Two Guide Wire 45Cm & 80Cm Or More (Logline Iv.) Peel-Away Sheath Glide Thru 5Fr*10 Cm, Guide Wire Nitinol 80 Cm, Guide Wire Nitinol 45 Cm Introducer Needle 21 G *7 Cm, Syringe - 10 Ml Tuer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape, 5 Fr Pressure Injectable Picc Line With Blue Flex Tip 40 Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter With Metal Guide Wire, 4Fr Single Lumen, Distalvalve, Saline Flush Only Size 45Cm Or More Usfda/ Four Digit Notified Ce Approved (Logline Iv.) Internal Stylet, Statlock Stabilization Device (Suture Less), Introducer Needle, Micro Introducer With Vessel Dilator, Guide Wire- 50 Cm Nitinol, Safety Scalpel,Suture Wing, End Cap , Vascular Catheter With Metal Guide Wire 3Fr Single Lumen,Micro Introducer,Contrast Media Compatible, Size 45Cm Or More (Logline Iv.) Usfda/ Four Digit Notified Ce Approved Syringe 12 Ml,Internal Stylet,Measuring Tape,Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G, Micro Introducer With Vessel Dilator,Guide Wire-50 Cm Nitinol,Needle Introducer 21 G, Safety Scalpel, End Cap , Vascular Catheter 7Fr-16 Cm With Chlorhexidine, Silver Sulfadiazine Coated Triple Lumen Usfda/Bis With Testing Standard. Introducer Needle 18 G., Spring Guide Wire 45 Cm J Tip, Dilator 8.5 Fr., Raulerson Spring Introduction Syringe 5 Ml , Vascular Catheter 5Fr/16G, Double Lumen Length 50Cm.Usfda/Four Digit Notified Ce Approved. Should Have Two Guide Wire 45 Cm & 80Cm Or More(Logline Iv.) Peel-Away Sheath Glide Thru 5Fr *10 Cm, Guide Wire Nitinol 80 Cm, Guide Wire Nitinol 45 Cm, Introducer Needle 21 G *7 Cm, Syringe-10 Ml Luer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape,5 Fr Pressure Injectable Picc Line With Blue Flex Tip 50 Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter 5Fr/16G, Double Lumen Length 55Cm.Usfda/ Four Digit Notified Ce Approved, Should Have Two Guide Wire 45Cm & 80Cm Or More (Logline Iv.) Peel-Away Sheath Glide Thru 5Fr *10 Cm,Guide Wire Nitinol 80 Cm,Guide Wire Nitinol 45 Cm,Introducer Needle 21 G*7 Cm, Syringe-10 Ml Luer-Lock, Skin Protectant Prep Pad, Second Site Adjustable Hub, Measuring Tape,5 Fr Pressure Injectable Picc Line With Blue Flex Tip 55Cm, Dressing Statloock Stabilization Device (Suture Less) , Vascular Catheter With Metal Guide Wire 5Fr Double Lumen, Introducer Safety Piv Catheter20g, 45Cm Or More (Logline Iv.) Usfda/ Four Digit Notified Ce Approved Syringe 12 Ml, Internal Stylet, Measuring Tape, Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G,Micro Introducer With Vessel Dilator,Guide Wire-50 Cm Nitinol,Needle Introducer 21 G,Safety Scalpel, End Cap , Vascular Catheter With Metal Guide Wire,5Fr Triple Lumen, Size Range 55Cm Or More (Logline Iv:) Usfda/Four Digit Notified Ce Approved Syringe 12 Ml, Internal Stylet, Measuring Tape, Stat Lock Catheter Stabilization Device (Suture Less), Introducer Safety Peripheral Iv Catheter 20G,Micro Introducer With Vessel Dilator, Guide Wire-50 Cm Nitinol, Needle Introducer 21 G, Safety Scalpel,End Cap , 3 Way Stop Cock , Non Pyrogenic & Single Use, Should Be Leak Proof, With Smooth Movements , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 10 Cm (Non Pyrogenic & Single Use) , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 50 Cm (Non Pyrogenic & Single Use) , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 100 Cm (Non Pyrogenic & Single Use) , 3 Way Stop Cock With Extension Tube (Vein -O-Line) Size 150 Cm (Non Pyrogenic & Single Use) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 16) • Graduated Bag, • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 20) • Graduated Bag • Should Have Well Fitting Cap • Soft Drainage Catheter 50 Cm Long, With Radio Opaque Line • Rounded Open Distal End With Smooth Atraumatic Eyes In Catheter • Catheter With Markings At 2 Cm Interval , Nasal Pronge Neonatal (Flexible Medical Grade, 2 Meter Long, Multichannel Kink Resistance Tube , Elastic Adhesive Bandage Bp 1M X 10Cm Adhesive Material Should Have Good Quality Sticking Property, Non-Allergic , Sterile Disposable (Single Use Teflon/Ptfe I.V Cannula With Integrated 3 Way Stop Cock Size 26G · Should Be Packed In Transparent Single Blister Pack · Should Confirm To Is 10555 Standard · (Neonatal Iv Cannula Size 26) , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Large Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Ventilator Without Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Medium Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Ventilator Without Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Large Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Bipap With Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Adult · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads For Adults In Medium Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear. · Should Be Single Use For Bipap With Vent · Non Allergic, Leak Proof, Contour Should Be Maintained , Niv Mask (Noninvasive Ventilation Mask) Paediatric · Should Be Light Weight Silicon Based Full Face & Nasal Mask With Face &Forehead Soft Cushion Pads In Small Size. · Should Be With Ergonomically Designed Clips/Straps For Easy Disengagement Of The Head Gear · Should Be Single Use With Bronchoscopy And Co2 &O2 Port With Chin Support · Non Allergic, Leak Proof, Contour Should Be Maintained , Nebulization Mask Adult , Nebulization Mask Paediatric , Chemotherapy Port &Non-Coring Needles(Adult) · Valved Catheter Need Only Saline Flush, Catheter With Intermediate Size Port With Small Septum And Silicon Filled Suture Holes, Should Be Mri Compatible With Cathlock Radio-Opaque Ring. 8Fr With Silicon Material With Peel Apart Percutaneous Introducer System. · Chemo Port Huber Needle 20G And 22G. , Chemotherapy Port &Non-Coring Needles(Pediatric) Valved Catheter Need Only Saline Flush, Catheter With Intermediate Size Power Port With Large Septum And Silicon Filled Suture Holes, Should Be Mri Compatible With Cathlock Radio-Opaque Ring. 6Fr With Silicon Material With Peel Apart Percutaneous Introducer System Chemo Port Huber Needle 20G And 22G. , Core Biopsy Instrument With Compatible Co-Axial Needle (Automatic Disposable) , Bone Marrow Biospy Needle , Eyelid Occlusion Dressings Use For Eyelid , Eye Pressure Shield , Nonabsorbable Polypropylene Light Weight Macroporous Mesh. Usfda/Ce Certificate With Nnotified Body. , Three Dimensional Monofilament Polyester Composite Mesh With Collagen With Glycerol Anti Adhesive Barrier Visceral Side And Stay Suture In Parietal Side Along With Medial. Circular Usfda/Ce Certificate With Notified Body , Three Dimensional Monofilament Polyester Composite Mesh With Collagen With Glycerol Anti Adhesive Barrier Visceral Side And Stay Suture In Parietal Side Along With Medial. Circular Usfda/Ce Certificate With Notified Body , Absorbable 5 Mm Hernia Mesh Fixation Device 30 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4-5 Mm (Should Not Be More Than 5Mm) Length Along With Flexible Shaft Up To 3 Cm. Circular Usfda/Ce Certificate With Notified Body , Absorbable 5 Mm Hernia Mesh Fixation Device 15 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4-5 Mm (Should Not Be More Than 5Mm) Length Along With Flexible Shaft Up To 3 Cm.Circular Usfda/Ce Certificate With Notified Body , Non Absorbable 5 Mm Hernia Mesh Fixation Device With 30 Helical Shaped Titanium Tacks 3.96 Mm Width And 0.61 Mm Diameter Usfda/Ce Certificate With Notified Body. , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape , Linear Cutter 55Mm With Six Rows, 3D Staple Formation, Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only , Linear Cutter 75Mm With Six Rows, 3D Staple Formation, Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only , Universal Linear Cutter Cartridge 75Mm Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 75Mm.Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only. 6 Rows 3-D Staple Technology. , Universal Linear Cutter Cartridge 55-60 Mm For Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 55-60 Mm.Option Of Closed Staple Height Of 1.5Mm/1.8Mm/2Mm In One Cartridge Only. 6 Rows 3- D Staple Technology. , Curved Cutter Stapler 40 Mm Linear Cutter Or Curved Shaped Radial Stapler Cartridge For Simultaneous Cutting And Stapling , Curved Green Cartridge Having Close Staple Height Of 2.0 Mm, Tactile Feedback On Completion Of Firing Sequence, New Anvil, Knife With Every Catridge , Circular Stapler 33Mm With Controlled Tissue Compression With Adjustable Staple Hight (1.5-2.2 Mm) For Controlled Tissue Compression Longer Staple Leg 5.2 Mm To 5.5Mm , & Non Slip Grip Surface , Laparoscopic Cartridge For Stapler 60 Mm Blue, 1.5 Mm Closed Staple Height With Gripping Surface Technology And Six Rows Compatible With All Range Of Endoscopic Linear Cutter 60Mm , Laparoscopic Cartridge For Stapler 60 Mm Green, 2.0 Mm Closed Staple Height With Gripping Surface Technology And Six Rows Compatible With All Range Of Endoscopic Linear Cutter 60Mm , Procedure For Prolapse And Hemorrhoids Stapler 33Mm - Hemorrhoidal Stapler Kit Consists Of 33Mm Hemorrhoidal Circular Stapler (With Fixed Anvil, Adjustable Closed Staple Height From 0.75 Mm - 1.5 Mm, Staple Open Leg Length Of 4.0Mm - 5.5 Mm), Suture Threade, Circular Anal Dilator, Purse-String Suture Anoscope, Suture For Purse String. , Optically Guided Bladeless Trocar 12Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Optically Guided Bladeless Trocar 12 Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer Length 100Mm. , Facial Closure Device Contain - Optical Bladeless Trocar With Facial Closure Device Comaptible With Clear Cannula Have Two Side Opening Meant For Uniform Port Closure , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Varied Staple Height Reloads/Cartridges For 80 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob(Both Side Firing) ,Linear Cutter Stapler With Integrated Gap Control Technology In 60 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 60 Mm Open Linear Cutter Reloads/Cartridges Purpule And Black , Eea Circular Stapler Purple Colour Medium Thick , Triple Row With Tristaple Technology (Three Row Of Staple Inner To Outer Row 3.0,3.5 And 4.0 Mm With Sloped Cartridges Face In One Stapler) Diameter 31Mm , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob(Both Side Firing) ,Linear Cutter Stapler With Integrated Gap Control Technology In 80 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 80 Mm Open Linear Cutter Reloads/Cartridges Purpule And Black , Wound Protector With Double Ring In Medium 5-9 Cm , Endo Catch Specimen Removal Kit:With Continuous Ring ,Polyurethane Pouch With 34.5 Cm Shaft Length , 10Mm With Leakproof And Impervious Material To Cancer Cells Of 0.5 Microns/ Pretied Purse String On Pouch Usfda Approved , Disposable Laparoscopic Clip Applier Preloaded With 15/16 Clips, 5Mm Diameter With Clip Logic Technology/Over Load Mechanism And Digital Display/Clip Indicator Titanium Alloy Clips- U Shaped. , Laparoscopic Liner Cutter Without Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 45Mm Capable Of Loading All Length Cartridges On Same Gun Only , Laparoscopic Liner Cutter With Or Without Integrated/ Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 60Mm, Capable Of Loading All Colour Coding 60Mm Cartridges On Same Gun. , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device,9Cm Length,16Mm Curved Active Blade With Adaptive Tissue Technology Capable Of Sealing Blood Vessels Up To And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip- Focus 9 , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device,17Cm Length,16Mm Curved Active Blade With Adaptive Tissue Technology Capable Of Sealing Blood Vessels Upto And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip - Focus 17 , Advance Bipolar Hand Activated Probe With 5Mm Shaft Diameter And 35 Cm Shaft Length With 5 Mm Wide Straight Jaw Design With Seal Length Of 20Mm And Cut Length Of 16Mm,Sealing Vessel Upto And Including 7Mm Through Radio Frequency Energy And Having A Temperature Controlled Mechanism Within The Jaw And Having Articulation Of 110 Degree(55 Degrees On Both Sides) And Capable Of 360 Degrees Rotation , Advanced Bipolar Tissue Sealer 37 Cms, With 5Mm Shaft Diameter, 24 Mm Jaw Length, 21.8 Mm Cut Length And 13.4 Mm Jaw Aperture Designed For Use In Laproscopic Surgical Procedures With Curved And Tapered Tip And Uses An Advanced Algorithm For Intelligent And Efficient Energy Delivery. Device To Have Intuitive Design With Separate Seal And Cut Button And 360 Degree Continuous Shaft Rotation , Laparoscopic Shears 5Mm Diameter,36Cm Long, 18Mm Curved Coated Blade And A Clamp Arm With Tissue Pad, Capable Of Cutting,Sealing,Grasping And Coagulating Blood Vessels Up To And Including 7Mm In Diameter, 360 Degrees Rotation, Advance Hemostasis Hand Activation Mode For Sealing Vessels Upto 7Mm In Diameter ,Ergonomic Handle Compatible With Ultrasonic Energy Source, Capable Of Hand And Foot Activation With An Integrated Hand Piece And Transducer. , Connecting Cable For Ultrasonic Harmonic Scalpel For Open Energy Probes Compatible With Focus Plus Shear- Hp Blue , Connecting Cable For Ultrasonic Harmonic Scalpel For Lap Energy Probes Compatible With Ace Plus Shear Hp054 , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Plates - 2 Mm Thickness (2*2 ) Hole Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Plates - 2 Mm Thickness (1*2) Hole Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Plates - 2 Mm Thickness (1*1 ) Hole Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (2 Mm ) Diameter Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (1.5 Mm ) Diameter Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (2.5 Mm ) Diameter Drill Bit Machine With Insertion Tools , Platting For Maxillary Swing And Mandibular Fixation Surgeries (Titanium) Screw- (3 Mm) Diameter Drill Bit Machine With Insertion Tools , Speech Prosthesis For Laryngectomy 22.5Fr (6 Mm) , Speech Prosthesis For Laryngectomy 22.5Fr (8 Mm) , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 2.0,2.5 And 3.0 Mm Staple Heights Row For Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 45 Mm Tan Colour Code For Vascular Applications , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 3.0,3.5 And 4.0 Mm Staple Heights Row For Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 45 Mm Purpule Colour Code For Medium To Thick Tissue , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Black Varied Staple Height Of 4, 4.5 And 5Mm Leg Length , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 2*4Cm Or Size 2-3*5- 6Cm , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 5*10Cm Or Size 5-7*7- 11Cm Or Size 4*8Cm , Disposable 10 Mm Endoscopic Clip Applier With Facility Of Loading Clips Independent Of The Firing Mechanism: Medium/Large Size , Disposable Clip Applier Preloaded With 20 Clips, Superinterlock Security With Clip Design Technology Medium , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) , Urine Collecting Bag, Disposable 2000 Ml With Uroflow Meter , Central Neck Line - Double Lumen (Antimicrobial Coated/ Chlorhexidine , Silver Sulfadiazine Coated) Central Lumen Catheter, Double Lumen) 7 Fr Usfda/Bis With Testing Standard. , Microcatheter For Aneurysm, Two Tip, Outer Diameter-2.1 To 2.4 & 1.7 Fr. Inner Diameter- 0.017 To 0.015. Nitinol Brading, Straight Tip Compatible With 0.014Microwire. It Should Have Radio Opaque Tip & Hydrophilic Coating. , Straight Tip Microcatheter With Four Transtion Zone Proximal Stainless Steel Triple Braid, Distal Segment Stainless Steel With Soft Distal Segment Of 6 Or 10 Cm, Outer Layer Pebax,Inner Layer Of Stainess Steel Braid Coil, Ptfe & Polyolefin Elastomer With Proximal &Distal For Deploying Intracranial Device: Stent Deployment0.027.Id , Straight Tip Microcatheter With Four Transtion Zone Proximal Stainless Steel Triple Braid, Distal Segment Stainless Steel With Soft Distal Segment Of 6 Or 10 Cm, Outer Layer Pebax,Inner Layer Of Stainess Steel Braid Coil, Ptfe & Polyolefin Elastomer With Proximal &Distal For Deploying Flow Divertor Delivery With Single Tip Markar 0.027 Id , Flow Guided Microcatheter Extruded Construction Proximal Size 2.7 F Middle Size 2.4 F Distal Size 1.2 To 1.8 F Working Length 155 To 180. Catheter Endo Hole Diameter 0.009 To 0.13. Compatible With 0.007 To 0.010, It Should Have Radio Opaque Tip & Hydrophilic Coating Compatible With Dmso. , Stinless Steel Hydrophilic Coated 0.14 Neuro Guide Wire With Twister Technology, Microridge Design, Optimized Core Wire Profile 205Cm In Length & Coil Length 5Cm , Aortic Punch 4 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Aortic Punch 4.5 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Aortic Punch 3.6 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Laproscopic Port With Trocar 5Mm Optically Guided Bladeless Trocar 5Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. 14G X 11Cm To 20Cm , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode- Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. (Size 18Gx11cm Or Above) , Programmable Automatic Biopsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode- Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. (Size 18Gx15cm Or Above) , • Incise Drape Made Up Of Polyester Film With An Acryllc Adhesive That Contains A Complex Of Lodoform (N- Vinyl 2 Pyrrolldine) With A Lodine Concentration Of 0.092 Mg Lodine/Cm2. • Film Should Be Breathable And Conformable To Skin, Compatible With Povidone And Chg Skin Preps. • Lodine From The Drape Should Be Present In The Deepest Skin Layers (1000 Microns Depth) Where Hair Follces Exist Apart From Killing Microbes On Skin Layer. • Produst Should Be Registered As A Class ‘D Medical Devise With Cdsco India Since ItS A Antimicroblal Product. • It Should Be Gamma Sterile And Us-Fda Approved. Size Should Be 56Cm 45Cm (Adhoslve Area) , Rem (Return Electrode Monitoring) Single Use, Corded Patient Return Electrodes Conductive Adhesive Hydrogel With Usfda , Surgical Gloves 6.5 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Surgical Gloves 7 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Surgical Gloves 7.5 Non Latex Surgical Gloves Synthetic Polyisoprene Powder Free Overall Length 283Mm With Puncture Indicator Technology Usfda Approved , Ionic Silver Highly Absorbent Multilayer Foam Dressing With Broad Spectrum Antimicrobial , Bactericidal Efficacies And Having A Soft Siliconadhesive Wound Contact Layer , Providing Sustain Release Of Silver Upto 7 Days. Size: 10 Cms X 10 Cms And More , Self-Adherent Moist Wound Foam Dressing Made Up Of Multilayer Matrix With Soft Silicon Adhesive Layer For Pressure Ulcers/Bed Sores At Sacrum 16 Cms X 20 Cms And More , Double/Single Wall Resuscitator With Peep Valve In Adult (Double Wall Resuscitator With Peep Valve In Adult It Should Be Fully Autoclavable Double Wall With Hand Strap It Should Be Supplied With Autoclavable/Eto Reservoir Bag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult Bag Volume: Mark Iv (1300 Ml Or More) Weight: Adult (415 G) And More It Should Be Us-Fda, Ce & Iso Certified Adult , Double Wall Resuscitator With Peep Valve In Paediatrics It Should Be Fully Autoclavable Double Wall With Hand Strap It Should Be Supplied With Autoclavable Reservoir Bag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult & Peadiatric It Should Have Provision To Attach Manometer For Paediatrics Ambu Bag Bag Volume: Mark Iv Baby (300 Ml) Weight: Baby (190 G) It Should Be Us-Fda, Ce & Iso Certified , Single Patient Use Sebs Resuscitator (With Peep Valve In Neonatal 220-300Ml) • It Should Be Single Use Resuscitator Made To Sebs Material Not Pvc. • It Should Have Unique Single-Shutter Valve System For Reliable Functionality & Swivel Between Valve And Mask Permits 360° Positioning In Relation To The Patient • It Should Have Thin-Walled Compression Bag With Hand Strip. • Resuscitator Volume: Neonate(220-300Ml) • (Including Reservoir And Mask) • It Should Be Ce/Iso/ Us Fda Certified. Or As Per Who Specification. , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett • It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector (Iso). • It Should Be Ce/Iso, Us Fda Certified , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett • It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector (Iso). • It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga • It Should Be Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga • It Should Be Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce/Iso, Us Fda Certified , Silicone Pre-Formed Sga • It Should Be Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce/Iso, Us Fda Certified , Offset Connector Cardio Sensor Electrodes • It Should Have High Conductive Wet Gel To Ensure Reliable Traces. • It Should Be Design With Offset Connector To Prevent Artefacts From Disrupting The Readouts • It Should Have High Quality Ag/Agcl Sensor To Ensure Excellent Trace Quality • It Should Have Size Not More Than 72 X 68 Mm • • Sizes -Adult , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Ultrasorbs Ap Disposable Drypads, Dry Pad For Moisture Management, 58.4X90cm, With Breathable Layer, Super Absorbent Core, Aqua Shield Film And Air Permeable Back Sheet, Absorbency Of 1800-2300Gm, Usfda/Ce/Bis Compliant, Iso13485 Compliant , Over-The-Ear Nasal Cannula Over-The-Ear Nasal Cannula With Star Lumen, 50 Tubing, Must Be Flexible Contoured Lip Tab Provides A High Level Of Stability And Patient Comfort. Over-The-Ear Design For A Comfortable And Secure Fit, Crush- And Kink-Resistant Tubing. Usfda/Bis With Testing Standard. , Pediatric Nasal Cannula Pediatric Nasal Cannula Softech With Universal Oxygen Connector, 7 Star-Lumen Tubing Lightweight, Flexible Nasal Cannula With Standard Over-The-Ear Designed That Optimizes Fit And Stability, Soft Nasal Prongs Help Maximize Patient Comfort. Individually Packaged For Convenience And Sterility. Manufacturer Must Be Usfda Registered / Certified With En/Eu Iso 13485 / Applicable 510K & Ce Certification. , Volumetric Incentive Spirometer (Adult) Volumetric Incentive Spirometer (Adult) 4000 Ml And Above With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification , Volumetric Incentive Spirometer (Pediatric) Volumetric Incentive Spirometer (Pediatric) 2500 Ml With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Mask For Tracheostomy Adult Mask For Tracheostomy And Laryngectomy Aerosol Therapy Tubing Connector Must Swivels 360° For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Pardiatric Mask For Tracheostomy Pediatric Mask For Tracheostomy And Laryngectomy Aerosol Therapy Tubing Connector Must Swivels 360° For Ease Of Positioning; 22 Mm Od Connector Accepts 22 Mm, Corrugated Tubing And Nebulizer Tees. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Elongated Aerosol Mask Adult Elongated Aerosol Mask Adult With Under-The-Chin Design For Excellent Fit On Wide Range Of Face Sizes Must Be Clear, Soft Vinyl For Patient Comfort; Adjustable Nose Clip Assures Comfortable Fit; Specifically Designed For Aerosol Therapy; Must Be With Supplied With 6Ft -7Ft. Corr A Flex Corrugated Tubing, Featuring Cuttable Sections Every 6 In. Usfda/Bis With Testing Standard. , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Non-Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Conventional Single Water Trap Adult Conventional Single Water Trap (Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 72 In. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Ventilator Circuit Single Limb Portable Adult Ventilator Circuit With Universal Single Limb. Must Be Complete Kit With Main Circuit Hose, Exhalation Valve Manifold, Aerosol Hose, Patient Elbow Connector, Proximal Airway Pressure Line, Exhalation Valve Line, And Humidifier Limb. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Ventilator Circuit Single Water Trap Adult Conventional Single Water Trap (Non-Heated) Ventilator Circuits Are Available In A Variety Of Different Configurations And Styles.To Incorporate Standard Connectors For Use With A Variety Of Ventilators, Ported Wyes Allow Pressure Sensing And Temperature Monitoring And Include Tethered Caps, All Adult Conventional Circuits With 70-72 Inch. Long, Standard Ventilator Circuit With Straight Connector Inspiratory Limb Water Trap (For Use With Hmes Only). Manufacturer Must Be Us- Fda/ Eu Ce Four Digit Notify/ Iso , Infant Prong Cpap Cannula Infant Prong Cpap Cannula Nasal Size 0 With Designed To Reduce Trauma Associated With Delivery Of Infant Nasal Cpap. Must Be Soft Siliconised, Anatomically Curved Prongs To Enhance Fit. Luer Fitting On Expiratory Connector To Allow Proximal Airway Pressure Monitoring. Each Set To Include, Soft Siliconised Cannula; Inspiratory & Expiratory Elbow Connector; Knit Cap; Two 6 In. Hook And Loop Fastener Sections; Two 10 To 7.5 Mm Adaptors. Manufacturer Must Be Usfda Registered / Certified With En/Eu Iso 13485 / Applicable 510K & Ce Certification. , Fhme Heat And Moisture Exchangers With Bacteria Viral Filters Bacterial Filtration Efficiency≫ 99.99 % And Viral Filtration Efficiency ≫ 99.9999% . Filter Membrane Should Be Of A Hydrophobic Non-Woven Polypropylene Material. Should Be Tailored To Meet The Specific Needs Of Both Anaesthesia And Intensive Care. , Tracheostomy Hme: 1 Heat And Moisture Exchangers For Spontaneously Breathing Tracheotomy Patients. 2 Should Have In Built Oxygen Port. 3 Should Be Compact & Light Wt. 4 Should Be Suitable For Ambulatory Patients, Sampling And Suctioning Can Be Done Without Removing It. 5 The System Should Have Kink Resisting Oxygen Tubing , Double Lumen Endobronchial Tube Left: Size-37Fr Low Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Double Lumen Endobronchial Tube Left: Size-39Fr Low Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Manifold Manifolds In 2, 3, 5 Port With Configuration Of Left-Right Orientation, On-Off Handle, Full-Half Body, 200 Psi-500 Psi Rating And Wide Port Spacing. Should Have Clear Polycarbonate Body To Provide Durability And Visibility, Airless Rotator And Large Bore Inner Lumen Throughout Including Rotator Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard. , High Pressure Tube High Pressure Tubing In 25Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard. , High Pressure Tube High Pressure Tubing In 51Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard , High Pressure Tube High Pressure Tubing In 76Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard , High Pressure Tube High Pressure Tubing In 122,Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi Usfda/Bis With Testing Standard , High Pressure Tube High Pressure Tubing In 183Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda + Ce/ Dgci Or Usfda/Bis With Testing Standard , Torque Device Torque Device For .014 To .038 Standard And Hydrophilic Guide Wires With Squeeze-Load- Release Mechanism.Usfda Approved , Radial Band Radial Hemostatis Band In 24 Cm . Curved Backer Plat With Large Area & Clear Unobstructed Site Visibility, Convinient Tubing Clip With Two Check Valve Options And Device Stickers. Should Be Available With Standard Luer And Specialized Connection Syringe. Us Fda Approved , Radial Band Radial Hemostatis Band In 29 Cm. Curved Backer Plat With Large Area & Clear Unobstructed Site Visibility, Convinient Tubing Clip With Two Check Valve Options And Device Stickers. Should Be Available With Standard Luer And Specialized Connection Syringe. Us Fda Approved , Angiography Needle Angiography Needle In 18G, Length Of 2-9Cm. Should Be Available In Echo Enhanced & Smooth Finish, Ergonomic Hub With Bevel Orientation Point, Silicone Coated Stainless Steel To Reduce Needle Drag And Superior Sharpness To Facilitate Entry Into Tissue And Vessel Wall. Usfda Approved , Angiography Needle Angiography Needle In 20G, Length Of 2-9Cm. Should Be Available In Echo Enhanced & Smooth Finish, Ergonomic Hub With Bevel Orientation Point, Silicone Coated Stainless Steel To Reduce Needle Drag And Superior Sharpness To Facilitate Entry Into Tissue And Vessel Wall. Usfda Approved , Angiography Wire Ptfe Guidewire In .035, .038, In Regular Length. Should Have 3Mm J-Tip, Straight Tip, Pre-Coating For Smooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memory And Packed In Flush Hoop With J Straightener. Should Have Option Of Fixed Core, Movable Core, Heparin Coating, 1.5Mm J-Tip. Usfda Approved , Angiography Wire Long Length Ptfe Guidewire In .035, .038, With Exchange Length. Should Have 3Mm J-Tip, Straight Tip, Pre-Coatting For Smooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memory And Packed In Flush Hoop With J Straightener. Should Have Option Of Fixed Core, Movable Core, Heparin Coating, 1.5Mm J-Tip. Usfda Approved , H10ydrophilic Wire Long Length Hrophilic Guidewire Of .018, .025, .035, .038 In 150-180Cm Length With Straight, Angled Tip. Should Come In Stiff & Standard Configuration, Nitinol Core Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visibility, Hydrated Gel Coating And True 1:1 Torque. Usfda Approved. , Hydrophilic Wire Long Length Hydrophilic Guidewire Of .018, .025, .035, .038 In 220-260Cm Length With Straight, Angled Tip. Should Come In Stiff & Standard Configuration, Nitinol Core Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visibility, Hydrated Gel Coating And True 1:1 Torque. Usfda Approved. , Hydrophillic Braided Sheath Hydrophilic Braided Sheath Introducer In 4F To 7F, Length: 7Cm, 10-11Cm, 15-16Cm, 23-25Cm Or 7-25 Cm With The Option Of .018, .021, .025 Plastic Jacketed And Spring Coil Guidewire. Should Have Ultra-Thin Wall And Flat Wire Braiding Technology To Provide Support And Low Profile.Usfda Approved , Femoral Sheath With Needle Femoral Sheath In 5F To 8F, Length: 11-25Cm With Puncher Needle Of 18G And Guidewire Of .035, .038. Should Have Rotating Suture Ring, Snap-Fit Dilator To Prevent Slipping During Insertion And Holster Pack. Should Be Available In Polypropylene. Usfda Approved , Angiography Radial Catheters Diagnostic Radial Catheter With Radial Ultimate Curve In 4-6F. Lenght Of 100Cm, 110Cm, 125Cm. Should Have Four Type Of Radial Ultimate Curves. Should Have Flat Wire Braiding, Nylon Material, Thin Wall Design For Higher Flow Rates, Radio-Opaque Tip, Strain Relief And Winged Polycarbonate Hub. Us Fda Approved , One Loop & Triple Loop Snare Snare Kit(2-35Mm Diameter, 90-Degree Nitinol & Gold-Plated Tungsten Loop) And Multiloop Snare Kit(2-45Mm Diameter, Three Interlaced Nitinol Loops) For Foreign Body Retrieval, Should Come With Flexible, Reinforced, Strain Relief Hub To Reduce Buckling And Unique Peel Away Insertion Tool. Usfda Approved , Ptca Kit (1) Three Port Manifold With Knobs To TurnRight When Open (2) One Pressure Line, (3) Fluid Connecting Line, (4) Contrast Connecting Line, (5) One Three Way Stop Cock, (6) One Y-Connector Hemoststic Valve With Spring Type Push And Release Mechanism, (7) One Inflation Device With Manometer Upto 30 Atm (Easy To Operate With Luminescent Dial), (8) One Luer Lock Controlled Syringe Of 10 Ml With Finger Grip, (9) Insertion Needle, (10) Torque Device.Usfda Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material.Sizes Are 5Fr. , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes Are 6Fr , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.Separate Y Connectors Available For Different Tubes In The Pack.Catheter Is Made Up Of Medical Grade Silicon Material. Sizes Are 7Fr. , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning. Separate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes 8Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.S Eparate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes Are 10Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning. Separate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes 12Fr. Usfda/ Notified Ce Approved , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3Mm. , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3.5Mm. , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane,Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 5.5Mm , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering. T Size 13Fr . , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering. Sizes 16Fr. , Catheter Mount Double Swivel Connector, It Should Have Bronchoscopy Port . It Sholud Be Approved By Us Fda , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip,Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radiopaque Stripe, Gamma Sterilized Size - 20Fr Length (0.8 - 5.0) , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip,Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radiopaque Stripe, Gamma Sterilized Size - 24Fr Length (0.8 - 5.0) , Percutaneous Endoscopic Gastrostomy (Peg) 24Fr Percutaneous Endoscopic Gastrostomy (Peg) Medical Grade Silicone Construction.External Retention Ring .Universal And Bolus Feeding Port Connectors,Medication Port.Collapsible Internal Retention Bumper.Radiopaque Stripe And Bumper.Tubing Clamp.Eto Sterilized.Sizes - 24Fr , Anti Microbial Gloves 6 , Anti Microbial Gloves 6.5 , Anti Microbial Gloves 7 , Anti Microbial Gloves 7.5 , Anti Microbial Gloves 8 , Anterior Chamber Iol Pmma Material, Single Piece Kelman Multiflex Design5-6 Mm Optic Size With 12-13 Mm Overall Size Biconvex Power Range +12 To +24Should Be Iso Or Ce Certified. , Capsular Tension Ring Standard Capsular Tension Ringpmma Material With One Eyelet Each At Each End 10 Mm To 12 Mm Overall Diameter Sterile Should Be Iso/Ce Certified Mfg. , Neonatal High Flow Nasal Cannula Having 8 Litre Flow. Should Have Soft Tip . , Pur-Xro Catheter 20 Cm, 28G/1Fr Picc Line With Stylet, Splitting Needle With Securing Wings With 8 Cm Extension Tubing (Flow Rate 0.7Ml/Min) , Pur-Xro Catheter 30 Cm, 24G/2Fr Picc Line With Split Cannula And 10Cm Extension Tubing Over Catheter (Flow Rate 4.5Ml/Min) , Long Introducer Sheath (20-30 Cm Long) (Size 5Fr..) Us Fda + Ce/ Dgci Approved·Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath (20-30 Cm Long) (Size 6Fr.) Us Fda + Ce/ Dgci Approved·· Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath (20-30 Cm Long) (Size 7Fr.) Us Fda + Ce/ Dgci Approved·Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 4F Us Fda + Ce/ Dgci Approved·Sizes 4 Fr 10-20 Cm Long· Pack Must Include 18 G,-21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 5F Us Fda + Ce/ Dgci Approved·Sizes 5 Fr 10-20 Cm Long· Pack Must Include 18 G,-21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 6F Us Fda + Ce/ Dgci Approved· Sizes 6 Fr 10-20 Cm Long· Pack Must Include 18 G,-21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce/ Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce/ Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce/ Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Ptfe Coated Diagnostic Guide Wire - (Exchange Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Should Be Available In , 0.035 Inches Size· Should Be 240-300 Cm Long· Should Be Available As Straight Or J-Shaped Tip· Should Be Available Fixed As Well As Movable Core. , Hydrophilic Diagnostic Guide Wire - Radifocus Tarumo Type (Regular Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved·Should Be Available In 0.032 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 120-300 Cm Long , Hydrophilic Diagnostic Guide Wire - Radifocus Tarumo Type (Regular Length, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Should Be Available In 0.035 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 120-300 Cm Long , Radiofocus Miniplastic Guidewire (, Regular Stiffness) Us Fda + Ce/ Dgci Approved· Sould Be Available In 0.035 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 150-180 Cm Long , Judkins Catheter (Jr) Right Judkins Diagnostic Catheters In Various Standard Curves And Lengths. , Judkins Catheter (Jr) Right Judkins Diagnostic Catheters In Various Standard Curves And Lengths. , Judkins Catheter (Jr) Right Judkins Diagnostic Catheters In Various Standard Curves And Lengths. , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved ·Left Judkins Catheters Diagnostic In Various Standard Curves And Lengths. , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved ·Left Judkins Catheters Diagnostic In Various Standard Curves And Lengths. , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved ·Left Judkins Catheters Diagnostic In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Pigtail Us Fda + Ce/ Dgci Approved Left And Right In Various Standard Curves And Lengths. , Multipurpose Catheter Us Fda + Ce/ Dgci Approved Multipurpose Catheters In Various Standard Curves And Lengths. , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Left (Al) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Left (Al) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Left (Al) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheter Us Fda + Ce/ Dgci Approved Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths. · , Internal Mammary Catheter Us Fda + Ce/ Dgci Approved · In Various Standard Curves And Lengths. , Internal Mammary Catheter Us Fda + Ce/ Dgci Approved · In Various Standard Curves And Lengths. , Nternal Mammary Catheter 7Fr Internal Mammary Catheter Us Fda + Ce/ Dgci Approved · In Various Standard Curves And Lengths. , By-Pass Graft Catheter 5Fr By-Pass Graft Catheter Us Fda + Ce/ Dgci Approved, In Various Standard Curves And Lengths , By-Pass Graft Catheter 6Fr By-Pass Graft Catheter Us Fda + Ce/ Dgci Approved, In Various Standard Curves And Lengths , By-Pass Graft Catheter 7Fr By-Pass Graft Catheter Us Fda + Ce/ Dgci Approved, In Various Standard Curves And Lengths. , Transradial Diagnostic Coronary Catheter Tiger Type Diagnostic Coronary Catheters Of Tig Curves And Lengths Dedicated For Trans Radial Coronary Angiography And Brachial Approach Also Us Fda + Ce/ Dgci Approved · , Introducer Sheaths For Pediatric Use (Size 5 Fr.) With J Tip/Straight Introducer Wire Us Fda + Ce/ Dgci Approved· Between 5.5-7.5 Cm Long· 0.021 Inch Straight Introducer Guide Wire· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· With Integral Side Port With Attached 3- Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant· With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· Should Have Smooth And Resistance Free Insertion , Arterial Pressure Monitor Lines (100 Cm Long) Us Fda + Ce/ Dgci Approved·Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Arterial Pressure Monitor Lines (150 Cm Long) Us Fda + Ce/ Dgci Approved· Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Arterial Pressure Monitor Lines (200 Cm Long) Us Fda + Ce/ Dgci Approved· Should Be Soft And Kink Resistant· Should Give Reliable Pressure Measurements· Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End· Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines· Quality Certification Should Be Provided From Authorized Agencies. , Angio.Kit/Ptca Kit (3 Port Many Fold With Attached Tubing One Pressure Line + Two Iv Set Connecting Tube And Two Leurlock Syringe ) Us Fda / Ce/ Approved , Venaseal Closure System For Varicose Veins Usa/Fda Approved N Butyl Based Adhesive Formation 50/90/105/120 Cm 145 Cm(3/4/6/8 F ,014/0.35 Compatible , Bone Marrow Biopsy Needle Size 8G 4 & 6 With Diamond Bevel Tip & Tapered Distal Canula. Disposable Bone Marrow Biopsy Needle Should Have Ergonomic T- Handle Design With Seprate Handle Cap. Should Have Trocar/Diamond Tip For Easy Coring Of Bone. Should Have Triple Crown Cannula Tip With 6 Facets.Should Be Available With Narrow Acquition Cardle With Sample Size Verfication Marking Should Be Available In 8,11,13 Gauze Usfda/Four Digit Ce Approved , Silicone Foleys Catheter With Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheter With Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheter With Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium (Coated Internally & Externally Surfaces) , Silicone Foleys Catheter(18Fr, 2-Way) • Made From 100% Medical-Grade Silicone. • Biocompatible And Non-Reactive, Ideal For Long-Term Catheterization. • 2-Way Foley Catheter (Typically Available); • Smooth, Non-Stick Surface For Easy Insertion And Removal. • Integrated Silicone Balloon For Retention In The Bladder. • Radiopaque Stripe Throughout The Catheter Length For X-Ray Visibility. • Standard (Rounded) Tip. • Available In Sizes Ranging From: 18 Fr). • Follows International Color-Coded System To Identify French Sizes. • Large Symmetrical Drainage Eyes For Effective Urine Flow. • Latex-Free - Suitable For Patients With Latex Allergies. • Universal Funnel-Shaped Connector For Drainage Bag Attachment. , Cutting & Coagulations Device With Tissue Fusion Ligasure Technology Having Maryland Jaw Sealer And Divider With Wide Jaw Aperture 13Mm And Cut Length 18.5Mm With Shaft Rotation Of 350 Degrees And With One Step Sealing Mechanism. Should Have The Manual Cutting Mechanism. And It Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting & Coagulations Device With Tissue Fusion Ligature Technology Have Small Jaw Tissue Sealing System For Open Procedures Vessel Sealing Instrument With Cut Length Of 14.7 Mm, Seal Length Of 16.5Mm, Jaw Angle 28 Degrees. Should Have The Manual Cutting Mechanism.And Its Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligature Technology Laparoscopic Blunt Tipped Vessel Sealer And Divider 37 Cm Long 5Mm Instrument. Wide Jaw Aperture 14.5 Mm With Shaft Rotation Of 180 Degrees ; Multifunctional Laparoscopic Device For Tissue Fusion.And Its Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting & Coagulations Device With Tissue Fusion Vessel Sealing Technology Instrument For Open Surgeries With Instrument Length Between 21-23Cm And Electrode Length Between 17-21Cm Having 22 Degree Curved Jaw With Contoured Tip Activation Both Through Hand Activation And Foot Activation With A Manually Controlled Cutting Mechanism. , Cutting & Coagulations Device With Tissue Fusion Ligasure Technology Have 36Mm Jaw Length, 180 Degree Rotatable Instrument With Curved Blade For Large Volume Tissue. Should Have The Manual Cutting Mechanism. , Cutting & Coagulations Device With Tissue Fusion Vessel Sealing Technology Have Vessel Sealing Instrument For Open Surgeries With Reusable Clamp Length Between 16-23Cm, With 12-40 Degree With Straight / Curved Jaw And Its Should Have Including 7Mm Cutting And Coag With Usfda. , Double Lumen Catheter Size- 12 Frx16 Cm Double Lumen Catheter Size- 12 Frx16 Cm (Double Lumen Catheter With Kit Internal Juglar / Straight (Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter ,Dialator ,Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot)Size- 12 Frx16 Cm With Us Fda / Iso Ce Certified , Double Lumen Catheter Size- 12 Frx13 Cmdouble Lumen Catheter With Kit Internal Juglar / Straight (Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter ,Dialator ,Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot Size- 12 Frx13 Cm Usfda Along With Iso Ce Certified , Long Term Double Lumen Dialysis Catheter Size- 15 Fr X 27 Cm Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided Catheter, Pull Apart Sheath, Dialator, Tunnelling Stylet, Guide Wire J/S, With Disppenser And Injection Caps, Symmetrical Tip Retrograde And Antigrade Size- 15 Fr X 27 Cm Usfda Certification Along With Iso, Ce. , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter,Pull Apart Sheath, Dialator, Tunneling Stylet,Guide Wire J/S,With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter,Pull Apart Sheath, Dialator, Tunneling Stylet,Guide Wire J/S,With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Transperant Surgical Wound Dressing Size- 5X 5.72 Cm Tranparent Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidal Protection And Anti Microbial Property. Provide A Waterproof Sterile Barrier To External Contaminating Including Liquids, Bacteria Anf Viruses , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Proteciton And Anti Microbial Property , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property , Multi-Vent Mask Pediatric, Multi-Vent Mask Pediatric, Air Entrainment Masks, Must Be Safe, Simple Delivery Of Variable Oxygen Concentrations. Each Mask To Includes Color-Coded Diluters: Green For Low Concentration, White For Medium Concentration. Locking Ring To Secure Flow Setting. Must Include Adaptor For High Humidity Entrainment. Complete Kit With 7-Ft Oxygen Tubing. Manufacturer Must Be Us-Fda Registered & Certified With En/Eu Iso 13485 & Applicable 510K & Ce Certification. , Closed Suction Catheter Mdi Port Has Isolated Cleaning Chamber For Cleaning Catheter Tip With Mdi Port. Catheter Is Made Up Of Medical Grade Silicon/Poly Urethane Material, Catheter Has Zigzag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. Size 12-Fr Product Should Be Usfda Approved , Closed Suction Catheter Mdi Port Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip With Mdi Port.Catheter Is Made Up Of Medical Grade Silicon Material,Catheter Has Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. , Closed Suction Catheter Has Isolated Cleaning Chamber 12 Fr. Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material,Catheter Has Zig-Zag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. Size 12 Fr. , Closed Suction Catheter Mdi Port Has Isolated Cleaning Chamber For Cleaning Catheter Tip With Mdi Port. Catheter Is Made Up Of Medical Grade Silicon/Poly Urethane Material, Catheter Has Zigzag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. Size 14-Fr Product Should Be Usfda Approved. , Multifocal Iol Multifocal Iol (Multifocal Iol Biconvex, Single Piece Optic Size 6 Mm, Overall 12-13 Mm Haptics Hydrophobic Single Loop Or Hydrophilic Double Loop Uv Blocking 360 Degrees Square Edge, Sterile Packing Disposable Sterile Injector For Sub 2.8 Mm Incision Power +16 To + 25 D Diffractive Multifocal Design With Near Add +3 To +4 D Iso Or Ce Approved Samples Required For Approval , Glaucoma Drainage Implant (Valved) With Silicon Tube Adult , Glaucoma Drainage Implant (Valved) With Silicon Tube Paediatric , Scleral Fixiated Intraoccular Lense Single Piece Pmma: Optic6-6.5Mm, Overall13.5Mm Haptic With Hole For Suture Fixation , Central Line With Triple Lumen With Y Needle With Syringe And Guide Wire 7Fr To 8.5Fr With 15 Cm To 20 Cm Catheter With Tecoflex/ Polyurathane Material With Usfda Approved. , Post Operative Surgical Cover Dressings Hydrofiber/Foam Dressings With 1.2% W/W Impregnated Ionic Silver & Tripple Hydrocolloid Matrix Dressings With Broad Spectrum Bactricidal Efficacy With Gel Forming Technology, Ce, Iso & Fda Approved , Post Operative Surgical Cover Dressings Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver & Triple Hydrocolloid Matrix Dressings With Broad Spectrum Bactericidal Efficacy With Gel Forming Technology, Ce, Iso & Fda Approved , 2 Pcs Flat Base Ostomy Body Fit 60 Mm Kit 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 60Mm, Elastic Tape In Semi-Circular Shape With Hydrocolloid Adhesive For Extra Security Of Base Plate. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatic Hydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm), Neutral Grey Colour Standerd Size Belt Compatible For Bags Having 4 Ear Hooks , 2 Pcs Convex Base Ostomy Body Fit 60 Mm Kit Two- Piece System 6 Mm Aperture Convex With Integrated Flex Line Base Plate. Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 4 Ears Belt Lock.Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. Audible Click Sound Locking System With Highlighted Colour Lock Button. Coupling With Wave-Shaped Locking Bag. Window On Bag For Inspection 60Mm. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatic Hydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm)Neutral Grey Colour Standerd Size Belt Compatible For Bags Having 4 Ear Hooks , 1 Pcs Trasnparent Colostomy Body Fit 60Mm Kit One- Piece Colostomy Bag- Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.34 N/Mm), Bag Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Neutral Grey Colour Material. Triple Layer Filter With Full Circle Pre Filter And Three Times Fold Velcro Locking Drainage. One Side Transparent For Inspection 60Mm. Adhesive Remover Spray Consists Of Hexamethyldisiloxane And Cyclonentasiloxane Silicone Polymers For Easy Removal Of The Base Plate, Alcohol Free, Sting Free 50 Ml. Cream To Maintain Peristomal Ph Value (5.5) Of Skin Contain Magnesium Citrate, Glycerine, Petrolatum, Citric Acid To Moisturize And Prevent Damage To Skin 60 Ml. Non Alcoholic Ostomy Paste For Filling And Sealing The Peristomal Skin Around The Stoma Contains Polyaliphatic Hydrocarbon , Water Base , Gaur Gum 60 Gm. Ostomy Powder With Natural Ingredients Such As Cmc, Guar Gum And Xanthan Gum For Peristomal Skin Excoriation 25 Gm. Cleanser To Clean Skin Exposed To Intestinal Secretions Consist Of Isopropyl Alcohol, Allantoin, Natural Coconut Oil . Lubricating Deodorant To Neutralize Odour And Provide Lubricating Effect To Ensure Content At The Bottom Not Around Stoma For Easier To Empty Bag 250 Ml. Skin Barrier For Healthy Peristomal Skin Or Risk Of Skin Damage Due To Bady Secretions Or Skin Damage Already Developed Consist Of Polyethylene, Plasticizer, Polyamide, Artificial Resin, Cmc, Sis ( 20Cm*20Cm) , 2 Pcs Flat Base Ostomy Body Fit Bag 60 Mm 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Material .Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. Window On Bag For Inspection 60Mm . With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic. , 2 Pcs Flat Base Ostomy Body Fit Bag 70 Mm 2-Piece System Base Plate With Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock. Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Material .Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. One Side Transparent For Inspection. 70Mm. With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic , 2 Pcs Convex Base Ostomy Body Fit Bag 60 Mm Two-Piece System 6 Mm Aperture Convex With Integrated Flex Line Base Plate. Body Fit Additional Elastic Adhesive Technology (Elastic Modulus-0.18 N/Mm), With 2 To 4 Ears Belt Lock.Colostomy Bag, Consists One Barrier Foil And A Oecotex Certified Water Repellent Textile Material. Triple Layer Filter With Full Circle Pre Filter And Drainage Locking System. . Window On Bag For Inspection 60Mm. With Nursing Care Services And Trained Hospital Staff As Well Stomach Care Clinic , Antimicrobial Transperant Provides Immediate And Continuous Antimicrobial Protection With Integrated Chlorhexidine Gluconate (Chg) Gel Pad, Proven To Reduce Crbsi And Vascular Catheter Colonization, Size 11.5Cm To 8.5Cm, Breathable Film Coating Provides A Barrier To Microbes* And External Contaminants Size 11.5Cm To 8.5Cm, , Sterile Self Adherent With Lipido Colloid Technology / Safetac Layer Sterile Self -Adherent Patented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad, A Superabsorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. Size 13X13 Cm And More , Sterile Self Adherent With Lipido Colloid Technology / Safetac Layer Sterile Self -Adherent Patented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad, A Superabsorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. Size 10X25 Cm , Polysiloxane Or Silicone Gel Sheet For Scar Management. Size 10 * 10 Cm Or 10X18cm , Polysiloxane And Silicone Gel Sheet For Scar Management Size 5 X5 Cm , Triple Layer Antimicrobal Form Dressing For Burn Wound With Silver Sulphate, Silver Content 1.2 Mg/Cm 2 With Active Release Of Silver Upto 7 Days With Soft Silicon Atraumatic Wound Contact Layer For Painless Dressing Change. Product Should Be Ce/Usfda Certified Size 20X20 Cm (45Mm) + 15% Deviation Insize Will Be Acceptable. , Triple Hydrocolloid Skin Barrier Where No Cutting Is Required Comprised Of Pectin, Gelatin And Sodium Carboxy Methyl Cellulose,Elastomeric Polymers Extending Turtlenecking Effect And Rebounding Memory Technology With Audible Click And Flexible Tape Collar. , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0 Mm , Purple Colour Code, Usfda Approved , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0 Mm , Purple Colour Code, Usfda Approved 10Mm , Nasal Haemostatic Sponge Pack With Out Airway 8Cm , Nasal Haemostatic Sponge Pack With Out Airway 10Cm , Nasal Haemostatic Sponge Pack (With Airway) 8Cm , Flexomatlic Tube 3-8.5 With Stylet Reinforce Et Tube With Wiring From Tip To End. It Should Be Usfda/Ce/Bis/Is. , Disposable Transducers For Invasive Pressure Monitoring Compatible With Available System In Cath Lab In Smsh Us Fda + Ce/ Dgci Approved· Disposable Transducers For Invasive Pressure Monitoring· Should Be Compatible With Available System In Cath Lab (Iabp - Data Scope & Cath Lab Transducer) And Iccu At Smsh· Should Meet Highest Medical Industrial Standards· Quality Certification Should Be Provided Form Authorized Agencies , Dialyzer Size 1.3 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.4 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.6 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Dialyzer Size 1.8 Sqm Dialyzer With Blood Tubing Set Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Same Company. , Padiatric Dialyzer Size 0 .6 Sqm Padiatric Dialyzer (Dialyzer Should Be Synthetic Membrane Polysulfon/Polyethersulfon) Other Product Required For Hemodialysis 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector , Padiatric Dialyzer Size 0.8 Sqm Padiatric Dialyzer (Dialyzer Should Be Synthetic Membrane Polysulfon/Polyethersulfon) Other Product Required For Hemodialysis 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (3/8 Cir Rb Needle 40Mm Length 76 Cm)Size 1/0 , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 20Mm Length 76 Cm) Size 3/0 , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 30Mm Length 76 Cm) Size 2/0 , Absorbable Surgical Suture (Sterile Catgut), Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 30Mm Length 76 Cm) Size 1/0 , Absorbable Surgical Suture (Sterile Catgut), Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 40Mm Length 76 Cm)Size 1/0 , Absorbable Surgical Suture (Sterile Catgut), Bp/Usp Needled Suture Chromic (3/8 Rb Needle 30Mm Length 76 Cm) Size 2/0 , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (1/2 Cir Rb Needle 45 Mm Length 100 Cm) Size 1 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Rcutting Needle 26Mm, Length 76 Cm) Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) ½ Cir Rb Needle 20Mm Length 70 Cm Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 1/2 Cir Rb Needle 30Mm Length 90 Cm Size 2/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 1/2 Cir Rb Needle 30Mm Length75- 90 Cm Size 1/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 1/2 Cir Tapercut Needle (Heavy) 35- 40Mm Length 75-90 Cm Size 1 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) ½ Cir Rb Needle40mm Length 90 Cm Size 1 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) (1/2 Cir Conventional 25Mm Length 90 Cm)Undyed Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) (1/2 Cir Rb Needle 20Mm Length 70 Cm) Size 4/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide ) (1/2 Cir Rb Needle 40Mm Length 90 Cm Size 2/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) (1/2 Cir Rb Needle 40Mm Length 90 Cm) Size 1/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 3/8 Circle Cutting Needle 22Mm Length 45 Cm Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide) 3/8 Circle Cutting 16Mm Needle, Suture Length 70Cm Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk (1/2 Cir Rb Needle 20Mm, Length 76 Cm) Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk (3/8Cir Reverse Cutting Needle 26Mm, Length 76 Cm) Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk (3/8Cir Reverse Cutting Needle 45Mm, Length 76 Cm) Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suturepolyamide Monofilament Black (Nylon) (3/8 Cir Micropoint Round Body ,6Mm Length 38 Cm) Size 8/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Conventional Cutting Needle 16 Mm Length 70 Cm)Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Conventional Cutting Needle 19Mm Length 60 Cm.)Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cir Slim Blade Cutting Needle 15Mm Length 70 Cm) Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cir R Cutting Needle 40-45Mm Length 60-70 Cm.)Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cir R Cutting Needle 45Mm Length 70 Cm.)Size 1/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb 13 Mm Needle,Length 75Cm) Double Armsize 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8Cir Rb 16Mm Needle,Length 90 Cm) Size 6/0 , Non Absorbable Surgical Suture,Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8Cir Rb Double 8Mm Needle, Length 60 Cm)Size 7/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8Cir Rb 16 Mm Needle, Length 70 Cm) Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 30Mm Length 90 Cm) Size 1/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Heavy Needle 40- 45Mm Length 75-100 Cm) Size 1 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Double Needle Cutting Size 16-17Mm Length 70-90 Cm) Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Double Needle 17Mm Length 70-90 Cm) Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 25Mm, Length 90 Cm) Double Arm Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 30Mm, Length 90 Cm) Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Needle 17Mm Length 75 Cm) Double Arm Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Tapercut Needle,25 Mm Length 90 Cm) Double Armsize 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue Usp(3/8 Cir Conventional Cutting Pc-3Needle 15Mm Length 60Cm)Size 6/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8 Cir Rb 13Mm Needle, Length 90 Cm Double Armsize Size 6/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 16 Mm Length 70 Cm) Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8 Cir Cutting Needle 25Mm Length 45 Cm)Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Heavy 40Mm, Length 90 Cm) Size 1 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (L/2 Cir Reverse Cutting, 45 Mm Needle Length 100 Cm) Size 1 , Non Absorbable Surgical Suture, ,Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (3/8 Cir Rb , 8Mm Double Needle, Suture Length Of 70Cm) Size 8/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Circle Tapercut 13Mm Double Needle 70Cm)Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Circle cement concrete 13Mm Needle, Suture Length Of 70Cm) Double Arm Size 5/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Circle Tapercut Needle 17Mm Suture Length Of 90Cm) Double Armsize 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polypropylene Blue (1/2 Cir Rb Needle 25Mm, Suture Length Of 75Cm) Double Arm Size 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Polybutylate / Silicon Coated Polyster Braided Green/ Blue (1/2 Cir Tapercut ,17 Mm Double Needle, Length 75 Cm)Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Polybutylate / Silicon Coated Polyster Braided White (1/2 Cir Tapercut ,17 Mm Double Needle, Length 90 Cm) Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Polybutylate / Silicon Coated Polyster Braided Green / Blue (1/2 Cir Tapercut ,17 Mm Double Needle, Length 90 Cm) Size 2/0 , Non Absorbable Surgical Suture Sterilized Surgical Needled Suture Polybutylate / Silicon Coated With Polyster Braided (Green / Blue) 1/2 Circle Taper Cut , 17Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X L.5Mm Size 2/0 , Non Absorbable Surgical Suture Sterilized Surgical Needled Suture Polybutylate / Silicon Coated With Polyster Braided (Green / Blue) *With 1/2 Circle Taper Cut , 25Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X L.5Mm Size 2/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Braided Coated Polyster,Green/White Or Blue/White Coated Polyster Braided (Green / Blue) With 1/2 Circle Tapercut Double Needle 25Mm, Suture Length 90 Cm Size 3/0 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyglecaprone, Monofilament Sutures (1/2 Circle Oval Rb Needle 26Mm Needle, Suture Length Of 70Cm)Size 2/0 , Absorbable Surgical Sutures Polyglecaprone, Monofilament Sutures (L/2 Circle Oval Rb Contrast Needle 26Mm, Suture Length 70Cm) Size 3/0 , Absorbable Surgical Sutures Monofilament Sutures Polyglecaprone /Polyglyconate (L/2 Circle Cutting 16Mm Needle,Suture Length 70Cm)Size 4/0 , Absorbable Surgical Sutures Polyglecaprone / Polyglyconate, Monofilament Sutures (3/8 Circle Cutting24- 26Mm Needle, Suture Length Of 70-90Cm)Size 3/0 , Absorbable Surgical Suture (Synthetic) Sterilised Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Reverse Cutting 40- 50 Mm Length 70- 90Cm) Size 1 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Rb 31Mm Needle, Length 70Cm) Size 2/0 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Rb 30Mm Needle, Length 70Cm) Size 1/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet) 1/2 Circle Ct Round Bodied 40Mm, Gs Needle, Suture Length 90 Cm/ Size 1 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)1/2 Circle Ct Round Bodied 40Mm, Gs Needle, Suture Length 90 Cm Size 1/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet)1/2 Circle Round Bodied 30Mm, Suture Length 90 Cm/ Size 2/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)1/2 Circle Reverse Cutting,Os 40Mm, Suture Length 90 Cm Size 1 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet)1/2 Circle Reverse Cutting 36Mm, Os Needle, Suture Length 90 Cm/ Size 1/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet) 1/2 Circle Round Bodied 20Mm, Suture Length 70 Cm Size 3/0 , Absorbable Surgical Suture (Synthetic) Antibacterial Coated Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)3/8 Circle R Cutting, Ps-1,24Mm, Suture Length 70 Cmsize 3/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyamide Monofilament Black (Nylon) (3/8 Cutting Spatulated Edge Needle, Double Arm Needle 6 Mm, Suture Length 30-42 Cm Size 10/0 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Rcutting Needle 16Mm, Length 76 Cm) Size 5/0 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Cutting Needle 8Mm, Length 35 Cm) Size 6/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk With Needle Silk (3/8 Cir Rb Needle 20Mm, Length 76 Cm) Size 4/0 , Non Absorbable Surgical Suture, Sterilised Surgical Needled Suture Black Braided Silk With Needle Silk (3/8 Cir Rb Needle 16Mm, Size 5/0 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Rcutting Needle 16-19Mm Length 76 Cm) Size 4/0 , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyglyconate, Monofilament Sutures (1/2 Circle Oval Rb Needle 26-30Mm Needle, Suture Length Of 70Cm) Size 2/0 , Absorbable Surgical Suture Polyglyconate, Monofilament Sutures (L/2 Circle Oval Rb Contrast Needle 20-26M M, Suture Length 70Cm) Size 3/0 , Braided E Caprolactone Coated Lactomer 1, 90Cm Gs-25,37-40Mm1/2 Circle Taper Point , Braided E Caprolactone Coated Lactomer 2-0 90Cm Gs-25,3Omm1/2 Circle Taper Point , Braided E Caprolactone Coated Lactomer 1 90Cm Gs-25,37-40Mm1/2 Circle Reverse Cutting , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Taper Point, 90 Cm , Braided E-Caprolactone Coated Lactomer 3-0 75Cm C-14 , Undyed 24Mm 3/8 Circle Reverse Cutting , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,30Mm Needle, Size 2-0, 1/2 Circle Taper Point, 90 Cm , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Reverse Cutting Os Needle, 90Cm , Braided E-Caprolactone Coated Lactomer 0 90Cm Gs-24 , Violet 40Mm 1/2 Circle Taper Point , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,20Mm Needle, Size 3-0, 1/2 Circle Taper Point, 70 Cm , Braided E-Caprolactone Coated Lactomer 1-0 90Cm Gs-25 , Dyed/Undyed 37- 40Mm 1/2 Circle Reverse Cutting , Polyglactin 910 Violet Braided, 1, 35 Cm 1/2 Circle Reverse Cutting (Heavy) 23 Mm -25 Mm Needle , Polyglactin 5-0 Rb Oval ½ Circle 16 Mm 45 Cm , Polyglactin 5-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure Mp, Purest Form Of Triclosan, 26Mm Needle, Size 2-0, 3/8 Circle Cutting, 90 Cm , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone Coated With Purest Form Of Triclosan 97-103% & Above, Violet 1/2 Circle Taper Point, 17-20Mm Needle, Length 70Cm Size 3-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone Coated With Purest Form Of Triclosan 97-103% & Above, Violet 1/2 Circle Taper Point Rb-1, 17 Mm Needle, Length 70Cm Size 4-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 1/2 Circle Taper Point Rb-2, Double Needle, 13 Mm Needle, Length 70Cm Size 5-0 , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 3/8 Circle Taper Point, Bb Single Armed Needle 17 Mm Needle, Length 70Cm Size 5-0 , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 6-0 Rb 17 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 6-0 Rb 11 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 5-0 Rb 11 Mm Needle Length 90 Cm , Absorbable Surgical Suture Sterilized Surgical Single Armed Needled Suture Monofilament Polydiaxanone Violet 5-0 Rb 17 Mm Needle Length 90 Cm , Monofilament Polyglyconate 1 150Cm Gs-25 Loop, Green 48Mm 1/2 Circle Taper Point , Monofilament Polyglyconate 2-0, 75Cm Green 26-30Mm 1/2 Circle Taper Point , Monofilament Polyglyconate 3-0, 75Cm Green 20-26Mm 1/2 Circle Taper Point , Monofilament Polyglyconate 4-0, 75Cm Green 17-20Mm 1/2 Circle Taper Point , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 3-0,70 Cm,1/2 Circle Rb,20 Mm , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 4-0,70 Cm,1/2 Circle Rb,20 Mm , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 5-0,70 Cm,1/2Circle R.B.,13 Mm , Monofilament Glycomer 1 90Cm Gs-21 , Violet 37Mm 1/2 Circle Taper Pont , Monofilament Glycomer 2-0 90Cm Gs-21 , Violet 37Mm 1/2 Circle Taper Pont , Non Absorbable Surgical Suture, Sterilized Surgical Needled Black Braided Silk With Needle 1/2 Circle Round Body 30 Mm Needle , Length 70 Cm Size 2-0 , Braided Coated Non Absorbable Suture Usp 1-0 75 Cm X 2 , Braided Coated Non Absorbable Suture Usp 2-0 75 Cm X 2 , Braided Coated Non Absorbable Suture Usp 3-0 75 Cm X 2 , Silk Reel 4-0 , Braided Polyester Caoted With Silicon 2, 26Mm 1/2 Circle Rc 75Cm , Braided Polyester Caoted With Silicon 5, 55Mm 1/2 Circle Rc 75Cm , Polypropylene Blue Monofilament, 2-0, 90 Cm 1/2 Circle Round Body Double Needle26 Mm , Polypropylene Blue Monofilament Usp 3/0,2,90 Cm,1/2 Circle Taper Point (Double Armed),26 Mm , Polypropylene Blue Monofilament, 4-0, 75 Cm 1/2 Circle Round Body Double Needle 17 Mm , Polypropylene Blue Monofilament Usp 5/0,1,90 Cm,1/2 Circle Taper Point (Double Armed),18 Mm , Polypropylene Blue Monofilament, 6-0, 75 Cm 3/8 Circle Round Body (380 Microns) Double Needle (Cutting) 13 Mm , Non Absorbable Polypropylene Surgical Sutures Size:7-0,3/8 Circle C1 Taper Point Cv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,8 Mm,60 Cm , Monofilament Polybuetester Coated With Polytribiolate 6-0 75Cm 2Xcv-1X36 , Blue 9Mm 3/8 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 4-0 90Cm 2Xcv-23X36 , Blue 17Mm 1/2 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 7-0 60Cm 2Xmv-175-8 , Blue 8Mm 3/8 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 2-0 90Cm 2Xv-20X 36 , Blue 26Mm 1/2 Circle Taper Point , Monofilament Polybuetester Coated With Polytribiolate 3-0 90Cm 2Xv-20X36 , Blue 26Mm 1/2 Circle Taper Point , Non-Absorbable Synthetic Unidrectional Dual Cut Angle Barb With Welded Loop Or Tab End Made Up With Polybeutester Size 1, 37Mm, 30Cm, 1/2 Circle, Taper Point , Synthetic Nonabsorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polybeutester Blue Size 2-0, 1/2 Circle, 37Mm, 30Cm Taper Point , Absorbable Synthetic Unidirectional Dual Cut Angle Barbed With Welded Loop Or Tab End Made Up With Polyglyconate 2-0 26-30 Mm 30 Cm 1/2 Circle Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 1-0, 1/2 Circle, 37Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 2-0, 1/2 Circle, 26Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 3-0, 1/2 Circle, 26Mm, 30Cm Taper Point , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop On End Madeup With Glycomer Blue Size 2-0, 1/2 Circle, 24Mm, 30-45Cm Rc , Polyester Ethylene Terephthalate Nonabsorbable Surgical Braided, Sterile, Surgical Suture Composed Of Poly (Ethylene Terephthalate.) Long-Chain, Linear Polyesters 1 /2 Circle Tapercut 2 X V-5 Double Needle 26 Mm 90 Cm Green Color Size 2-0 , Laproscopic Knotless Pga -Pcl Bidirectional Taper Point Surgical Suture Self Fixation Device With Autolock Mechanism Made Up Of Pga -Pcl Bidirectional Taper Point 17 Mm & 32Cm , Absorbable Antibacterial Polydiaxonone Monofilament Taper Point Surgical Suture Absorbable Antibacterial Suture Made Up Of Polydiaxonone Coated With Triclosan Violet Monofilament 1/2 Circle Taper Point Ct-1 40 Mm Needle 90 Cm Suture Size 1 , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 1-0,90 Cm,1/2 Circle R.B.,30 Mm , Non-Absorbable Surgical Suture Black Braided Silk 1-0 Rc 3/8 Circle 45 Mm 76 Cm , Non-Absorbable Surgical Suture Black Braided Silk 5-0 Rc 3/8 Circle 12 Mm 76 Cm , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 5-0,76 Cm,3/8 Circle R.B,12 Mm , Non-Absorbable Surgical Suture Black Braided Silk 6-0 Rc Mp 3/8 Circle 8 Mm , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 2-0, 1/2 Circle Taperpoint, 36 Mm,100 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 6-0 Rb Micro Point ¼ Circle 8 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 4-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 3-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 5-0 cement concrete 3/8 Circle 16 Mm 45 Cm , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Violet 5-0 Rb Oval 1/2 Circle 16 Mm 45 Cm , Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 26Mm Length 70Cm3-0 , Non Absorbable Surgical Suture Sterilized Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm4-0 , Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm 5-0 , Non Absorbable Polypropylene Surgical Sutures Size:6-0,3/8 Circle 175-6 Taper Point /Rc Bv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm 13 Mm , Non Absorbable Polypropylene Surgical Sutures Size:7-0, Compound Curve ( 1/2 & 3/8 Circle) Circle 175-6 Taper Point Blackmatte Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm , Monofilament Synthetic Absorbable Suture Poliglecaprone 25 - Undyed Ep 3-0,70 Cm,1/2 Circle Oval R.B. J.B. Needle,26 Mm , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 3-0, 3/8 Circle Reverse Cutting,Ps Prime 24 Mm,75 Cm , Gauze Than 120Cm X 9 Mtr (Jk47) , Absorbent Cotton Wool Ip 500 Gm , Cotton 200 Gm (Jk153) , Cotton Bandage 4Inch (4.0419) (10Cm X 9 Mtr ) , Cotton Bandage 6Inch (4.042) (15Cm X 9 Mtr ) , Baby Diaper Small (Pba001) , Disposable Appron / Plastic Appron , Shoe Cover (Jk201) , Disposable Needle 22No , Disposable Needle 23No , Disposable Needle 24 No , Disposable Needle 26 No , Infant Feeding Tube 6G (4.0747) , Spinal Needle With Pencil Point Tip Having Tranparent Grooved Hub And Introducer Needle Size 27G X 3.5Inch (4.1315) , Opthalmic Micro Surgical Crecent Blade , Opthalmic Micro Surgical Knife(Keratom) , Ear Buds , Medical Body Protector Premium , Pure Type 1, Triple Helical, Porous Collagen In Particle Form (Fish Origin) With Mupirocin Usp 2% W/W And Metronidazole Ip 1% W/W, Size- 10Ml , Super Oxidized Solution With Neutral Ph Containing Hypochlorous Acid (0.003%) And Sodium Hypochlorite (0.004%) For Wound Treatment In Spray Bottle Of 500Ml , Advanced Fluid Administration System With Air Stop & Prime Stop With Integrated Back Check Valve Bacterial Retention Air Vent, Transparent Spike Designed In Accordance With Iso 8536-4, Transparent Drip Chamber (Double), 15Micron Fuild Filter In The Chamber Medical Grade , Porus Resorbable Collagen (Pure Type-1) Sheet In Nylon Mesh-Dry Form (Fish Origin)-Size- 10X10cm , Non-Occulusive Wound Contact Layer Consists Of Silver Healing Matrix Made Ofp Polyester Mesh Impregnated With Hydrocolloid Particles( Cmc), Petroleum Jelly, Polymers And Silver Salts With Demonstrated In Vitro Antibacterial Activity Upto 7 Days, Using Lipido- Colloid Technology (Tlc) , Size-10X12cm , Pure Poly Siloxane Based Silicone Scar Management Product In Sheet Form(100% Poly Siloxane And Nylon Polyamide Mesh) -Size- 10X10cm, , G Dress 10.5*25Cm , G Dress 8.5*6.5Cm , Amorphous Hydrogel In Applipak Composing Of 2.3% Carboxymethylcellulose,20.0% Propylene Glycol & Purified Water, Promotes Rapid But Gentle Debridement Of Necrotic Tissue. Size 25Gm , Triple Chambered Nutrition(3 In One) For Periperal Iv Emlusions 1800Ml-2100Ml With 80% Olive /20% Soya Lipid,Amino Acids,Glucose & Electrolytes. Tpn 1Ltr Triple Chamber Bag Should Contain Protein 20-45 Gm/L Lipid 20-40Gm/L Glucose 80-160 Gm/L , Non-Leadradiationprotectiongloves - Bis Certified , Latex Free Disposable Pencil Point Spinal Needle 27G , 127.5 Mm With Grooved Transparent Hub With Centering Protective Plastic Sleeve, Touhy Needle With Black Eye - 18 G (1.3 X 88 Mm). Protrusion Of Spinal Needle Through The Back Eye Of The Epidural Needle. With Epidural Catheter, Filter, Loss Of Resistance Syringe And Separate Locking Device - Docking System. , Electrolysed Non-Toxic, Non-Irritant And Non-Corrosive, Ready To Use Disinfectant Solution With Neutral Ph Containing Sodium Chloride (Na Cl)- )0.023%, Sodium Hypochlorite (Naocl)- 0.005%, Hypo Chlorous Acid (Hocl)- 0.004%, Electrolysed Water- 99.97% In Jerricane Of 5 Litre
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
6.
Defence #11413644 Technical Bid
Tender For Repair And Maintenance Of Chs Alongwith Connected Items At Various Units At Bhimbat,Thasgam & Drass Under Ge Kargil.- 1 Dismantling The Existing Burner Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed. 2 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For De- Carbonization , Descaling And Refractory Cement And Assemble The Same And Testing Complete All As Specified And Directed. 3 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr By Using Brush And Vaccum Cleaner Complete All As Specified And Directed. 4 M&L For Descaling Of Boiler By Circulating The Descaling Chemical Using Circulating Pump Into The Boiler And Kept It For Approx 4 Hours For Descaling And Flushing Off The Chemical After Descaling Of Boiler Complete All As Specified And Directed. 5 M&L For Refractory Cement / Heat Resistance Cement Of Boiler Assembly Of Heating Plant Complete All As Specified And Directed. 6 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 20Mm Complete All As Specified And Directed. 7 Supply And Fixing In Replacement Of Solenoid Valve Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 8 S&F In Repair Of Photo Cell Sensor Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Make - Cofi Complete All As Specified And Directed. 9 S&F In Repair Hydraulic Pressure Gauge Showing Reading 0-20 Bar With Accuracy +/- 2.5% To Be Connected With 15 Mm Dia Gi Pipe Complete With Suitable Size Of Battery Complete All Accessories And Protection Cover. 10 S&F In Repair Digital Temperature Controller (Dtc) Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 11 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 12 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 13 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 14 S&F In Repair Of Nozzel 60 Degree Complete All As Specified And Directed. Make : Danfoss Or Equivalents Make. 15 Replacement Of Old Unserviceable Minor Part For The Control Panel Including Repairing Of Wiring Etc As Per Existing, Complete All As Specified And Directed By Engr-In-Charge. 16 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 17 S&F In Repair Thermostat Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 18 S&Fin Repair Sequence Controller Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 19 S&F In Repair Contactor 25A, 230V/440V Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 20 S&F In Repair Of Contactor 230/ 440V Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 21 S&F In Repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 Hz, 415 Volts Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 22 S&F In Repair Relay 6 - 10 Amps,3 Phase, 50Hz, 415 Volts Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 23 S&F In Repair Diesel Filter Assembly With Drain Port Complete As Per Sample. 24 S&F In Repair Fuel Pipe For Burner As Per Sample. 25 M&L For Complete Rewinding Of Electric Motor Of Capacity 5 Hp 3 Phase 415 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 26 M&L For Complete Rewinding Of Electric Motor Of Capacity 1 Hp Single Phase 230 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 27 All As Per Item No 26 Above But Capacity 0.5 Hp Single Phase 230 Volts. 28 Repair Of Chimney 7Mtr High Complete With Welding Including Iron Pieces, Plates, Outlet Cover And Necessary Modification And Cleaning Complete Removal Of All Kinds Of Dust Both Internal And External Parts And Free From All Kind Of Dust/Dirty Spots Of Chimney, Complete All As Specified And Directed By Engr-In-Charge. 29 M&L For Elastomeric Nitrile Rubber Foam Insulation Sheet For Ducts Having Anti Microbial Properties Having Thickness 10 Mm With Suitable Adhesive Complete All As Specified. 30 Dismantling Of Unserviceable/Damaged Hepa Filters And Supply And Fixing Of Hepa Filters With Al Box And Flange Type Of Size 640 X 460 X 50 Mm With Frame Having Efficiency Of 3 Microns Complete All As Specified. 31 M&L For Cleaning Of Existing Hepa Filters With Pressurized Potable Water By Using Pressure Pump And Water Spray Gun, Dry The Filters With Compressed Air After Cleaning Complete All As Specified. 32 Supply And Topping Up Of Antifreeze (Coolant) Suitable For -35 To -40 Degree Celsius To Be Filled In Reservoir Tank For Central Heating System As Instructed By Engr-In-Charge. 33 S&F Of Threaded Thermometer Having Range -50 To +100 Degree Celsius With Accuracy +/-2.5% To Be Fixed On 15 Mm Dia Gi Pipe Complete With All Accessories. 34 M&L For Rewinding Of Ahu Blower Motor Cap 5 Hp And Testing After Repair Complete All As Specified. 35 M&L Charges For Servicing Of Air Handling Units Including Blower Cleaning, Balancing Of Blower Motor Pully Complete All As Specified. 36 S&F In Replacement Of Supply Air Diffuser Alongwith Collar Damper Of Size 600 X 600, Neck Size 450 X 4550Mm All As Specified. 37 M&L For General Maintenance, Inspection And Servicing Of Chiller Unit By (Make-Bluestar Model No. Xac2S-010R2) Cleaning Of Condenser And Evaporator Coils Of The Chiller Unit By Using Specialized Cleaning Solution And Pressure Washing, Inspections Of The Compressor And Water Pump For Leaks, Noise, And Proper Functionality, Verifying The Integrity Of Electrical Components, Including Wiring, Breakers And Sensors, Parts, Lubrication Of Moving Parts, Checking Of Any Refrigerant Leaks, Checking Performance Testing And Optimization. 38 M&L For Repair/Replacement Of Faulty Components, Fixing Any Refrigerant Leaks And Vaccum Testing And Performance Evaluation After Refilling, Replacement Of Worn Out Gaskets, Seal And O-Rings For Chiller Of Capacity 9.2 Tr Complete All As Specified And Directed. 39 Supply And Charging Of Refrigerant Gas R-407C As Per Existing For Chiller Of Capacity 9.2 Tr And Testing After Charging Complete All As Specified And Directed. 40 Supply And Topping Up Of Compressor Oil As Per Existing Grade Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 41 Supply, Installation, Testing In Replacement Of Hermetic Type Scroll Compressor Unit , Suitable For 9.2 Tr Capacity Chiller Unit (Make-Bluestar Model No. Xac2S-010R2) Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Bluestar/Godrej / Lg Or Equivalent. 42 S&F In Replacement Of Expansion Valve As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 43 S&F In Replacement Of Filters & Driers As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 44 S&F In Replacement Of Pressure Switches As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 45 S&F In Replacement Of Control Relays As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 46 S&F In Replacement Of Fan Motor Of Cooling Tower As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 47 S&F In Replacement Of Temperature Controller As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 48 Dismantling The Existing Burner Assembly Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed By Engr-In-Charge. 49 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 30000 Kcal/ Hr For De- Carbonization And Assemble The Same And Testing Complete All As Specified And Directed By Engr-In-Charge. 50 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity Capacity 30000 Kcal/ Hr By Using Brush And Vaccum Cleaner Or Blower Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Gun Metal Of Size 25Mm Complete All As Specified And Directed By Engr-In-Charge. 52 S&F In Repair Of Photo Cell Sensor Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Repair Dtc Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 54 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 55 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 56 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 57 S&F In Repair Of Nozzel 60 Degree Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 58 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 59 S&F In Repair Thermostat Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 60 S&Fin Repair Sequence Controller Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 61 S&Fin Repair Solenoid Valve Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 62 S&F In Replacement Of Chimney Exhaust Of 6 Inch Dia Made Of Auminium Sheet Including Bends And Outlet Cover Complete All As Specified And Directed By Engr-In-Charge. 63 Dismantling The Existing Radiator Unit Of Capacity From 3000 To 6000 K Cal Per Hour, Taking It To Nearest Workshop Cleaning The Complete Unit With Coil Shine Chemical, Detecting The Leakage Portion By Applying Nitrogen Gas Pressure, Brazing The Leakage Portion, Refixing The Same Unit From Dismantled Location Including Testing On Load Complete All As Directed At Site By Engineer-In- Charge. 64 Supply And Laying 3 Layer (Inner Antimicrobial, Outer Uv Stabilized) Isi Marked Is-15801 Pp-R Pipe And Pp-R Plain Fittings In Walls Or Laying In Floors Complete Of Size Outer Dia 25 Mm Including All Fittings (Surface Remitting Also Included). 65 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 25Mm Complete All As Specified And Directed. 66 S & F In Replacement Thermostat Suitable For 126/165/195/310 Litres Capacity Refrigerators All As Directed. 67 Supply And Charging Of Refrigerant Gas As Per Existing For Refrigerator Of Capacity 126/165/195/310 And Deep Freezer Of Capacity 300/320/400/500 Ltr Capacity Including Testing After Application Of Nitrogen Gas Pressure To Find Out Any Leakage, Brazing And Stopping Of All Leakage Detected, Re-Application Of Nitorgen Pressure To Ensure Leak Proof Gas Circulator System Flushing Out The Nitrogen Gas Complete All As Specified And Directed. 68 S&F In Replacement Of Compressor Unit , Suitable For 165/195 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 69 S&F In Replacement Of Compressor Unit , Suitable For 126 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 70 S&F In Replacement Of Compressor Unit , Suitable For 310 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 71 S&F In Replacement Of Copper Capillary Tube With All Fittings For Refrigerator Of Cap 126/165/310 Ltr Complete All As Specified. 72 Repair To Voltage Stabilizer For Automatic Operation Single Phase Naturally Air Cooled, Indoor Type Designed For Output Variation Between 170 To 250 V With Output Voltage Stablized At 230 V With Accuracy Of +/- 2.5 % And Capacity 1 Kva And Making Connection With Ac Complete All As Specified & Directed. 73 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 50 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 74 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 25 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 75 M&L For Replacement Of Unservicible Inner Shell Made Of Stainless Steel 1.5Mm Thick Suitable For Geyser Inclusive Of Glass Wool As An Insulating Material For Geyser Of Capacity 25-50 Ltrs. 76 M&L For Replacement Of Thermostat For Geyser 0 To 80˚ C Complete All As Specified And As Directed By Engineer-In-Charge. 77 M&L For Flexible Pvc Connection Pipe For Geyser Of Length 1.5 Feet As Per Sample. 78 M&L For Replacement Of Pressure Release Valve For Geyser Of 25 Ltr Having Size 15Mm Dia. 79 M&L For Replacement Of Heating Element For 25 Ltr Geyser Capacity Round Type 1.5 Kw As Per Sample. 80 M&L For Replacement Of Heating Element For 25 Ltr Cap Triangle Type 1.5 Kw As Per Sample. 81 M&L For Replacement Of Geyser Assembly Suitable For 25 Ltr Geyser As Per Sample. 82 Repair And Replacement Of Kerosine Oil Batti Including Blower, Burner For Hammam 500 As Per Sample Complete All As Specified And Directed. 83 S&F Brass Tap Size15/20 Mm For Hamam As Per Sample Complete All As Specified And Directed. 84 M&L For Replacement Of Heating Element As Per Sample Suitable For 500Ltr Hammam As Per Sample. 85 S&F In Repair Of Compressor New Sealed Unit, Suitable For 300/320 Ltr Capacity Deep Freezer And Testing On Full Load Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete In All Respect Complete All As Specified And Directed By Engr-In-Charge.Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 16
Jammu And Kashmir View Result →
7.
Civil Aviation #11410905 AOC
Bids Are invited for Operation Of Bhs Including Supply Of Spares And Decorative Lighting At Mvi Airport Ayodhya Boq Item No. 1 - Operation Of Baggage Handling System ( Both Arrival And Departure ) By Engaging Following Minimum Man Power. A) Electrician Cum Operator/ Technician - Skilled - 04 Nos ( All Days Including Weekly Offs & Holidays).B) Skilled - 01 No. For Data Entry & Other Miscellaneous Work (In General Shift For Six Days In A Week )Note- Contractor Has To Provide Reliever On Weekly Offs / Holidays Of Above Required Staffs Except For Sl. No. B) , Boq Item No. 2 - Supply Of Red Outer Lens For Rwy End Light Suitable For Existing Airfield Ground Lighting System (Agl) Complete As Required .( Existing Light Fixture Is Of Vardhman Make ) , Boq Item No. 3 - Supply Of Green Outer Lens For Rwy Threshold Light Suitable For Existing Airfield Ground Lighting System (Agl) Complete As Required .( Existing Light Fixture Is Of Vardhman Make ) , Boq Item No. 4 - Supply Of Yellow Filter For Runway Edge Light Suitable For Existing Airfield Ground Lighting System (Agl) Complete As Required .( Existing Light Fixture Is Of Vardhman Make ) , Boq Item No. 5 - Supply Of 200W, 6.6/6.6A Halogen L Pk30d(64382 Hlx-C) Make - Osram Or Equivalent Suitable For Existing Agl/ Cat-I Fittings Complete As Required . , Boq Item No. 6 - Supply Of Isolating Transformer Of 200 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required. , Boq Item No. 7 - Supply Of Wind Socks (Cloth) For Wdi(White/Red) Suitable For Existing Sgs Make Wind Sock. , Boq Item No. 8 - Supply Of 360 Degree Outer Clear Lens For Runway Edge Light Fitting Suitable For Existing Light Fixture Of Vardhman Make. , Boq Item No. 9 - Supply Of Clear Spreader Lens For Approach Light Fitting Suitable For Existing Light Fixture Of Vardhman Make. , Boq Item No. 10 - Supply Of Clear Lens For Papi Suitable For Existing Papi System Of Vardhman Make. , Boq Item No. 11 - Supply Of 2Cx 4 Sqmm. Annealed Tinned Copper Conductor Pvc Insulated Pvc Sheathed Unarmoured Flexible Afl Secondary Lead Up To Voltage Garde 1.1 Kv Conforming To Relevant Is Up To Date Ammendment Complete As Required. , Boq Item No. 12 - Supply Of Minimum 9 W Led Type Aviation Obstruction Light In Red Colour Having Die-Cast Aluminum Housing With Red Polycarbonate Dome For Better Illumination, Integral Driver, Ingress Protection - Ip65 (Make- Bajaj Or Equivalent As Approved By Eic) , Boq Item No. 13 - Supply Of 30 W Movable Led Flood Light (Yellow Colour) (Make - Philips , Type - Bvp102 30 Or Equivalent) Complete As Required At Site. , Boq Item No. 14 - Supply Of 150 A, 1000V, 50 Sq. Mm Terminal Block Suitable For Mounting On Din Rail Suitable For Existing Panel Complete As Required At Site. , Boq Item No. 15 - Supply Of Led Driver Of 80W, 25 V Suitable For Existing Airfield Signage Board (Make-Electrosystem) Installed In Operational Area Complete As Required At Site. , Boq Item No. 16 - Supply Of 15 W Led Suitable For Existing Taxiway Light Fitting Of Vardhman Make Complete As Required At Site. , Boq Item No. 17 - Supply Of Electronic Driver Suitable For Existing 15 W Led Taxiway Light Fitting Of Vardhman Make Complete As Required At Site. , Boq Item No. 18 - Supply Of Mnx 70 Type 3 Pole Power Contactor Having Ac-3 Duty, 70A Rating, Ac1 -100 A Rating, Coil Voltage- 230V Ac, Suitable For Lighting Switching Applications, Panel Mounting, Conforming To Conforming To Is/Iec 60947-4-1 Etc. Complete As Required. , Boq Item No. 19 - Supply Of Isi Marked, Heavy Duty, Rigid Pvc Conduit, Size- 25 Mm Dia, Confirming To Is 9537 (Part 3) Complete As Required At Site. , Boq Item No. 20 - Supply Of National Flag Of Size 9144 Mm X 6096 Mm As Per Bis Specification No Is 1-1968 Latest Complete As Required At Site. , Boq Item No. 21 - Supply Of 18 Mtr Length Tri-Colour Led Rope Light Having Transparent Pvc Type Body Material, Ip65 Protection, Smd Led Strip As Per Lm 80/Is16106, Conforming To Is 10322 And Suitable For Operation On 240 V, 50 Hz Single Phase Power Supply Complete As And When Required. (Make-Philips/Halonix/Crompton/Bajaj/Osram) Total Quantity : 2123
Contract Date: Ref. Documents Contract Value : 66.89 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
8.
Defence #11408076 AOC
Bids Are invited for Cleanroom Equipment And Electrostatic Discharge Protection Solutions Ultra-Pure Nitrogen Distribution And Energy Optimization System For Controlled Environments , Contamination-Controlled Garment Storage And Suspension System , Esd-Compliant Ergonomic Seating System With Integrated Armrests For Controlled Environments , Static Dissipative Work Surface Assembly With Bench-Mounted Ionization Module , Integrated Electrostatic Discharge Control And Measurement System For Cleanroom Applications , Controlled Environment Particulate Extraction And Air Displacement Unit , Portable Particle Quantification Unit For Controlled Environments , Cleanroom-Compatible Portable Particle Monitoring System , Lightweight Maintenance And Access Platforms For Controlled Environments , Industrial Weighing And Load Measurement Systems - Platform And Suspended Crane Type , Static Dissipative Storage Container And Bin System For Subsystem Protection And Organization , Air-Tight Cleanroom Access Door With Overhead Closure And Controlled Airflow Interface , Controlled Cleanroom Utility System, Transport, And Cleaning Assembly With Esd Safe , Controlled Environment Protective Wear And Static Dissipative Consumables For Personnel Safety , Electrostatic Discharge Control Accessories And Cleanroom Contamination Control Materials , Footwear Organization And Storage Assembly With Self-Closing Access Mechanism For Cleanroom Applications , Cleanroom Monitoring And Access Control System With Environmental Display , Esd-Safe Cleanroom Consumables For Surface Cleaning, Particle Removal, And Static-Protected Packaging , Electrostatic Discharge Safe Precision Handling And Assembly Tool Kit For Electronic Component , Integrated Differential Pressure Measurement With Silicone-Free Sealing System For Cleanroom Applications , Cleanroom-Compatible Waste Collection Bins With Liner Provision Total Quantity : 2066
Contract Date: Ref. Documents Contract Value : 4.24 Crore
Government Departments No of Bidders 8
10.
Educational and Research Institute #11403991 AOC
Purchase Of Psychology Equipment , Aesthesiometer (Divider Typ) (Two Point, Graduated Aesthesiometer,All Metal Electro Plated) , Colour Mixer (Also Called Colour Wheel) (Electrically Operated. Variable Speed. Used For Study Of Visual Phenomena Of Colour Perception Of Complementary And Non-Compelmentary Colour Development) , Colour Contrast Apparatus (Different Colour Plates Are Used To Show The Phenomenon Of Colour Contrast. An Indispensable Apparatus To Introduce The Said Phenomenon.) , Successive Contrast Or After Image Apparatus: (The Phenomenon O£ After Image Can Be Studied. The Apparatus Is Handy, Well Furnished And Provides All Materials Required For Studying The Said Phenomenon.) , Depth Perception Apparatus:(The Box With 3 Needles Provides Enough Room For Studying The Depth Perception With Electric Bulb.) , Lifted Weights Set (Metal): (A Set Of 12 Metal Tubes With Removable Or Fixed Tops Containing Certain Weights. Fine Finish And Superior Quality. This Is Required In Weight Discrimination Experiments In Psychophysics For Differential Limen (Dl), Upper Differential Limen U Dl), Lower Differential Limen (Ldl) Determination.) , Muller-Lyer Illusion Figure (With Stand & Scale): (A Study And A Handy Set Of Mullerlyer Illusionfigure. Horizontal Type With A Stand To Adjust The Figure To The Desired Eye Level Of The Subjects. Variable Figure Operated By Smooth Sliding Of The Figure (In Front Of The Experiment) On An Attached Mm Scale. Fine Ficish And Superior Quality Of Work (20‘) , Answer Sheets For Muller- Lyer Illusion (A Pkt.Of 100) , Size-Weight Illusion (Collins-Drever Model) (A Set Of 24 Tubes With Two Standard Stimuli Of Different Weights. Fine Finishing And Superior Quality. Supplied In A Wooden Handy Box.) , Vertical Horizontal Illusion. (T And L Forms With Stand And Scale.) , Optical Illusion Chart:(Cloth Bound Showing Fifteen Well-Know A Illusion, Five Each Of Extent, Direction And Perspective.) , Phi-Phenomenon Apparatus: Electronics.(Consists Of Two Lights Holding Small Cabins With Variable Positions And Time Exposures. Requires Marcury Cup Metronome Also, If An Automatic Operation Of The Apparatus Is Desired.) , Perception-Influence Of Set:(Two Sets Of 12 Cards, Each Of Which Contains A Pair Of Geometrical Figures. One Series Introducing A Set And The Other Serving As An Experimental Series Ideal For Studying Influence Of Set) , Visual Space Perception Apparatus:(Consists Of Well Polished Wooden Box(Size: 30X12X L9J. Having Two Fixed Lights And A Third Movable One With Slides In The Box Perpendicular To The Plane Formed By Tbe Two Fixed Uprights. A Fixed Scale On Top Of The Box Enables One To Find Errors. The Inside Of The Box Is Illuminated By Means Of Two Lamps. Viewing Slit Is Provided On The Smaller End.) , Vase And Face Figures. (In 5X 5 Size On Sturdy, Iraported Card Board. , Galton Bar: (It Is One Of The Early But Still Very Popular Psychophysical Experiments To Demonstrate The Problems Of Subjective (Psychological) Equality. , Whipples Weight Box: (Consists Of 2 Standards And 20 Comparison Weights. The Weights Are Made Out Of Light Metal And Not Of Cardboard As Made By Some Foreign Firms. Supplied With An Attractive Box Lined With Velvet To Hold Weights In Individual Compartments) , Shape And Size Discrimination Apparatus:((T.K.K. Japan Model) This Device Examines The Subjects Size Discrimination Ability Relying Upon Visual And Tactile Sensations As Well As Speed Of Shroting. The Subject Inserts 50 Small Discs Or Coins. Which Are Different In Size And Thickness In Five Different Ways, Into The Corresponding Slit Of Holes As Fast As Possible. The Practice Is Allowed Only Five Times And The Test Is Repeated Twice.) , Colour Preference Cards:(A Set Of 8 Cards Of Different Colours.Can Be Exposed Through The Gravity Tachistoscope) , Colour Preference Wheel: Colour Preference Wheel:(Used For Colour Preference. Using Pair-By-Pair Comparison Method Colour Reference Wheel Is Operated.) , Conflict Board:(With Step Down Transform Mer And A Pad Of 84 Sheets Along With Manual For Demonstrating Experimentally The Reactions To (1) Approach-Avoidance, (2) Approach-Approach, (3) Avoidance Avoidance And (4) Double Approach-Avoidance Situations. A) Manual Available) , Card Sorting Square Tray:(A 4X4 Square Tray Has Been Specially Designed To Eliminate Space Error On Changing The Position Of The Tray. The Pigeon-Hole Numbers Can Be Changed Into Four Different Patterns Simply By Changing The Position Of The Movable Plywood Back Of The Tray, Fine Finish And Superior Quality Work.) , Electric Maze (Human Maze ):(Two Desig Ns On The Same Maze (One For The Experimenter And The Other For The Subject Alternately). Teak Wood, Light Or Sound Signals For Count Ing Errors. Impulse Counter Can Also Be Used. Specially Planned According To The Designs Of The Mazes To Plot The Procedure And Progress Of Learning From Trial To Trial. 420 Points. With Manual. (A)Ebonite Stylus (B)Electrically Operated (C)Electrically With 6 Digits Error Counter (D)Electronics With Digital Timer & Counter. (E)Record Blanks.For Mazes 1 And 2, (A Pkt. Of 100) , Electric Maze Witb Stylus (Human Maze):(Finished With Good Polish, Having 219 Contacts And A Binding Post. Supplied With Stylus.) , Learning By Recognition Method:(A Set Of 35 Cards With Instruction Sheets.) , Slot Maze:(Designed Completely Controlled) , Memory Drum:(Electrically Operated, Four Variable Speed, High-Quality) , Immediate Memory Spantest:((English): (A)Form A (A Pad Of 100)(B)Form B (A Pad Of 100 ) (C)Manual) , Mirror Drawing. (Apparatus: Size 15X 12” X 3/4 Folding Type. Plywood Surface With Hard Plastic Base To Assure Smooth Movement Of The Stylus On Which The Metallic Pattern Is Fixed. For The Electrical Operation, Over All Body Is Made Of Plywood. With Manual: (A)Electrically Operated (B)Electrically With 6 Digits Error Counter (C)E1ectronics With Digital Timer & Counter.) , Mirror Drawing Apparatus: (For Hand Operation, With A Wooden Cover And Star Sheets.) , Short-Term-Memory Test By C.B.Dwivedi (English) ((A)Manual (B)Cards Of Ccc Trigrams (A Pkt. Of 15) (C)Cards Of Meaningful Triads (Pkt.Of 15) , Long-Term Memory Test By C.B. Dwivedi (English):((A)Manual (B)List Of Words For Recognition Test (A Pkt. Of 100) , Pyramid Puzzle:(The Pyramid Problem Involves Placing A Series Of Graduated Blocks On One Of Three Posts Such That A Larger Block Is Never Placed Over A Smaller Block. Useful For Demonstration Of Problem Solving. In Sight Learning And Concept Formation. Average Solution Time With New Subject Is About 20 Min. Repeated Trials With The Same Subject Will Produce Successively Shorter Solution Time.) , T-Puzzle:(For Problem Solving Studies. All Made Up Of Plastic, Superior Quality And Fine Finish) , M-Puzzle (For Problem Solving Studies. All Made Up Of Plastic, Superior Quality And Fine Finish.) , Habit Interference Board With Cards. , Conditioned Reflex Apparatus:(A Thick Glass Plate Is Fixed In A Wooden Frame To Which Is Attached A Felt Hammer. The Hammer When Released Will Fly Up And Strike The Glass In Front Of The Eyes Of Subject. This Is Attached To Head Rest And Can Be Adjusted To Any Height. The Apparatus Is Mounted On A Table By Means Of Clamp Supplied With It. Used For Eyelid Conditioning Experiment.) , Pencil Maze:(A Durable Aluminium Maze With A Hard Surface Bottom To Prevent Grooving. Standard 8.5Al1” Paper Placed Under The Maze Produces A Permanent Record Of Subjects Performance. Can Be Used For A Variety Of Learning Problems.Subjects Are Blind Folded When Tracing The Maze. Speed As Well As Accuracy Can Be Studied Witb The Aid Of A Stop Watch Or Clock Timer.) , Human Problem Solving By C.B. Dwivedi (English):)With Instructions,Designof Experiment And Calculation Procedures. May Also Be Used For Studying The Influence Of Set On Problem-Solving. (A)Booklet : (I) 30 Problem Work Sheets (A Pkt. Of 100) (Ii) 6 Problem Sheets For Studying The Influence Of Set (A Pkt. Of 100) (B)Manual , Water-Jar Problem Solving Test By N.K. Jain:(A Series Of 15 Problems Illustrated Jar Wise. This Is Ideal For Studying Problem Solving In Real-Life Setting. Four Problems Introduce The Situation Followed By Difficult Ones. To Be Used For Studying Effect Of Set On Problem Solving (A)Test Booklet (A Pkt. Of 100) (B)Manuai) , Nonsense Syllables Or Meaningless Word Lists (English)(: From 3 To 11 Syllables. Printed On White Paper And Also In List Form (Set Of 3 Pads) , Paired Associates Word Lists (English): (From 2 To 6 Words. Printed On Separate Sheets (Set Of 4 Pads).) , Massons Disc:(Used To Study The Fluctuations Of Attention.) , Span Of Attention Cards.(A Set Of 12 Cards Having Equal Sized Dots (From 3 To 14) Scattered Randomly. With An Instruction Sheet. Ta)Answer Sheet (A Pkt. Of 100) , Doc Figures (Same Dot Figures Are Used In Studying The Phenomenon Of Attention) , Tachistoscope(Jaiota-Gravity Type):( Tachistoscope With Three Different Adjustable Windows. The Tachistoscope When Unfolded Provides An Automatic Screen Between The E And S. All Leak Wood, Fine Gray Paint Or Polish. With Manual) , Tachistoscope(Fall Type):(Can Be Used For The Study Of Span Of Apprehension And Memory. All Teak Plywood Made, Fine Polish Or Gray Paint. Smooth And Comparatively Noiseless Operation Attempted.) , Judging Emotions From Photographs:(A Set Of 12 Photographs.) , Division Of Attention Board Apparatus:(Electrically Operated With Error Counter.) , Colour Preference Cards:(A Set Of 8 Cards Of Different Colours. Can Be Exposed Through Gravity Tachistoscope) , Colour Preference Wheel :(Used For Colour Preference. Using Pair By Pair Comparison Method Colour Preference Wheel Is Operated.) , Vernier Type Chronoscope:(Specially Made Of Heavy Bottom (All Metal) To Prevent Any Accidental Movements.) , R.T. Apparatus:(Giving Choice R.T. Using Two Light Stimuli) , Mental Fatigue Test By N.K. Jain (English):(With Instruction Sheet. (A) Numerical Sheets (A Pad Of 100) (B) Alphabetical Sheets (A Pad Of 100) (C) Instruction Sheet) , Work And Rest Test By M.C. Joshi (English):(A)Alphabetical Sbeets : Form A For Work (A Pkt. Of 100) (C)Numerical Sheets : Form A For Work (A Pkt. Of 100) (C)Manual , Normal Curve Demonstration Apparatus (Laffayate Model)(This Is An Effective Visual Demonstration Device For Showing The Natural Normal Distribution Curve And Illustrating A Graphic Picture Of The Law Of Probability. Marbles Should Be Inserted Through The Hopper To A Preset But Adjustable Position To Produce The Normal Distribution Curve. This Unit Is Ideal Both For Demonstration In Statistics Classes As Well As For Those Experiments Requiriag Assessments Of Normal Probability Phenomena By The Subject. Instruction Manual Is Also Available.) , Teaching Aptitude Scale By Sanjay’ Vohra (English):(This Test Has Ll9 Items. It Measures Aptitude In Eight Areas: Communication, Intelligence,Maturity, Perceptiveness, Persistence, Receptiveness, Social Warmth And Teaching Interest. This Test Is For Teachers And Takes 40 Min To Complete. A) Reusable Booklets (Pkt. Of 25) B) Answer Sheets (Pkt. Of 100)C) Profile Sheets (Pkt. Of 100) D)Scoring Key E) Manual , Duncans Sales Aptitude Test (Indian Adaptation) By Sanjay Vohra (English):(This Test Has Been Designed To Help In Appraising Sales Ability, Potential In Selecting Sales Personel. If Provides An Objective Measure Of One Important Aspect Of Sales Aptitude, Namely Knowledge And Understanding Of Basic Principles Of Selling. This Test Is For 18 Years And Above. 20 Min To Complete. A) Test Booklets (Pfit. Of 25) B) Answer Sheet (Pkt. Of 100) C) Scoring Key D) Manual) , Machanical Aptitude Tests Battery (Matb) By Atmananda Sharma (Hindi/English):(Time 25 Min. Age 13 To 17 Years, Class Viii Io Xii. Test-L: Mechanical Knowledge Measures ‘Knowledge Of Tools Of Children. Non-Verbal And Culture Free. Directions And Examples.Test-Ii: Mechanical Comprehension Measure Factor ‘M’ Of Children. Non-Verbal And Culture Free. Test-Ill: Space Relations- Measures Factors ‘S’ Spatial Visualisation Of Children. Non Verbal And Culture-Free. Test-Iv: Form Relations-Measures Factor ‘P, Perceptual Ability And Inductive Reasoning Of Children. Test-V: Mechanical Adaptability-Measures Background In The Field Of Science, Scientific Applications And Related Activities Of Children) , Multi Factor Interest Questionnaire By Kapoor & Singh (English )(It Provide Scores On Eight Factors- Business, Clerical, Agricultural, Mechanical, Scientific, Outdoor Activities, Aesthesties And Social Meant For 11 To 18 Years.) , Vocational Interest Record By S.P. Kulshrestha (English)(The Present Record Contains 200 Vocations Belonging To Ten Different Vocational Interest Areas - 1. Literary, 2. Scientific, 3. Executive, 4. Commercial, S. Constructive, 6. Artistic, 7. Agriculture, 8.Persuasive, 9. Social, 10. Household. This Test Is Suitable For Delta And Higher Secondary Students, As Well As For The Students Of Colleges And Also For Soung Adults Out Of Schools And Colleges. (A}Test Booklets (A Pit. Of 100) (B)Manual , Educational Interestrecord By S.P. Kulshrestha (English):(The Present Record Contains 98 Edcational Subject/Activities Belonging To Seven Different Education Al Interest Areas. They Are -1. Agriculture, 2. Commerce, 3. Fine Arts, 4. Home Science, S. Humanities,6. Science, 7. Technology.(A)Test Booklets (A Pkt. Of 100) (B)Manuai , Student Teacher Value Inventory By Meenakshi Biswal (English)((A)Test Booklets (A Pkt. Of 100)(B)Manual) , Adjustment Inventory By Nilima Deka (English):((A)Test Booklets (A Pkt. Of 100} Manual) , Bells Adjustment Inventory By Huge M. Bell (English):((A)Tesl Booklets (A Pkl. Of 100) (B)Manual (C}Scoring Key) , Marital Adjustment Questionnaire By P. Kumar & Kanchana Rohtagi (English):(This Is Having 27 Items In Yes Or No Type Scale, And Reliability And Validity Indices Have Been Worked Out. Percentile Norms Are Given. Age Ranging From 28 To 45 Years. (Test Booklets (A Pkt. Of 100) (B)Manual) , Test Of Democratic Values By Alok Gardia (English):(A Reliable & Valid Test Of Democratic Values Which Contains 40 Multiple Choice Items. The Test Measures Six Democratic Values Namely Dignity Of Individual, Liberty, Equality’, Justice. Cooperation & Tolerance. It Can Be Administered On Upper Primary To Higher Secondary Students.The Test Is Also Suitable For Prospective Teachers (B.Ed. Students) And Teachers Of Different Schools. It Can Also Be Administered On Students Of Higher Education. (A)Test Booklets (A Pkt. Of 100) (B Manual) , Personal Adjustment Inventory For Creative Children By C.B. Asaha English):((A)Test Booklets (A Pkt. Of 100) (B)Manual) , A Test For Measuring Decision Making Capacity Of Educational Administrators By A.K.Pandey (English): ((A)Test Booklets (A Pkt. Of 100)(B)Manual) , Prosocial Behaviour Scale By Mahejabin& P.C. Shukla: (New)(This Tool Based On Likert Scale. The Scale Comprises 36 Items, On The Basis Of Six Dimensions. It Can Be Administered On The Secondary And Higher Secondary School Students. Split-Half Reliability Of The Testis 0.77 And Cronbach Alpha Is 0.794. This Test Measures The Level Of Prosociality, Which Indicates High Academic Achievement, Well Adjustment, Healthy Teacher-Taught Relationship And Social Harmony. Therefore, This Test Is Very Helpful To Develop Healthy Adjustment Skill, To Develop Healthy Reiationsbips& Social Harmony. This Tool Can Also Be Used As An Indicator Of Academic Achievement & Healthy Personality.A) Test Booklets (A Pkt. Of 100) B) Manual , Verbal Test Of Intelligence By M. Asthana And K.B. Verma (English):(This Test Covers Eight Areas Of General Mental Ability, Viz, Best Answer, Reasoning, Similar, Opposite, Analogy’, Mathematical Series, Mathematical Instruction And Classification.Norms Have Been Prepared Age-Wise. Age 13 To 21 Years. Time 20 Min No. Of Item100. (A)Resuable Test Booklets (A Pkt. Of 20) (B)Answer Sheets (A Pkt. Of 100) (C)Manual (D)Scoring Key(Stenciltype) , Group Test Of General Mental Ability By S. Jalota (English):(It Is A Point Scale Of General Ability For College-Educated Adults. (A)Resuable Test Booklets (A Pkt. Of 20) (B)Answer Sheet (A Pftt. Of 100)(C)Manual (D)Scoring Key) , The Southend Test Of Intelligence (English)((A)Test Booklets (A Pkt. Of 100) (B)Manual (C)Practice Sheets (A Pkt. Of 100) , On-Verbal Intelligence Test By Atmanand Sharma:(It Measures ‘G’ Of Children Age 11 To 16 Years, Grades Vi To X. Ii Is Culture-Free. Working Time 25 Min. (A)Tesl Booklets (A Pkt. Of 10) , Emotional Intelligence Test (For Adolescents) By Meena Jain & Madhu Jain:((A)Booklets (A Pkt. Of 100) (B)Manual) , Emotional Intelligence Test By Rakesh Pandey(Age Group 18 To 35 Years. The Scale Is Based On The Most Widely Used And Scientifically Validated Ability Model Of Emotional Intelligence Proposed By Mayer And Salovey. It Is A 51-Items Self Report Measure That Provides A Quick Assessment Of The Your Dimensions Of Emotional Intelligence, (A) Perception, Appraisal And Expression Of Emotion, (B) Emotional Facilitation Of Thinking, (C) Understanding And Analyzing Emotions, Employing Emotional Knowledge, (D) Reflective Regulation Of Emotion To Prompt Emotional And Intellectual Growth. The Scale Has Been Validated On A Wide Range Of Population And May Be Administered To Any Age Group Capable Of Comprehending Verbal Expressions. The Authors Have Tried This Scale On Adolescents And Adults Also And Found It Reliable And Valid. The Scale Can Be Used In Clinical Setting As Well As In The Area Of Health Psychology, Educational Psychology’ And Other Areas Of Psychological Investigations That Focus On The Role Of The Ability To Understand, Manage And Utilize Emotions For Personal Growth And Well Being. (A)Test Booklets (A Pkt. Of 100) (Bjmanual) , Emotional Intelligence Scale By Udham Singh &K.Ozha (English): (Age Group 15 To 30 Years. No. Of Item 46. Dimension Measure In This Test Are - Knowing And Managing Our Emotions, Motivatiting Our Self, Knowing Others Emotions, Handling Relationship With Others.A)Test Booklets Qa Pkt. Of 100) (B)Manual) , Social Intelligence Test By S.Mathur (English):(No. Of Item 50. Age Range 14 To 50 Years. A) Test Booklets (A Pkt. Of 100) B) Manual C)Scoring Key) , Culture Fair (Free) Intelligence Scale Indian Print By Kapoor, Rao & Singh/Cattell And Cattell (Indian Adaptation):(Minimise Cultural Bias. These May Be Administered Individually Or In A Group. They May Be Used To Identify Learning Problems Of Individuals And Assess Applicants Potential To Perform Job Relevant Tasks. (A)Scale I (English) (Cfis-I): For 4 To 8 Years And Older Retardates. Time - 25 Min. Norms Mental Age And L.Q. (B)Scaie Ii(English/Hindi) (Cfis-Ii E): For 8 To 14 Years And Average L.Q. Adults. Lt Contains Four Sub Tests Involving Different Perceptual Tasks.Completing Series,Classifying, Solving Matries And Evalua Ting Conditions.Time Taken 15 Min. (C) Scale Iii (English/Hindi) (Cfis-Iii E): For 14 Years And Above, I.E., Senior Secondary, College And High I.Q. Adults. By Employing Four Distinct Tasks, The Composite Intelligence Measure Avoids Reliance On A Single Skill. The Scale Is Recommended When Testing Better Educated Or More Intelligent Individuals, Because Of The Higher Difficulties Level Of Items And A Greater Refinement In The Higher Intelligence Ranges.) , Bhatia Battery Performance Test Of Lntelligence By C.M. Bhatia(Age Ii To 16 Years.) , Alexanders Pass Along Test:(Age L0+ Years Complete Set With Duco Painted Material And Design Cards Contained In A Wooden Or Plastic Box With Record Sheets (Pads Of 50) And Manual.) , Indian Adpatation Of Binet-Simon Scale((1960) By S.P. Kulshrestha) , Cube Construction Test:(Complete Set Witb Duco Painted Material And Models In Wooden Or Plastic Box Witb Record Sheets (Pad Of 50 Each With Manual) , Kohs Block Design Test:(Age 10* Years. Complete Set With Duco Painted Material And 17 Design Cards In Plastic Box With Record Sheets (Pads Of 50 Each) And Manual) , Manikin Test:(Six Pieces Representing Six Major Parts Of The Human Body To Be Fitted Together To Make A Conventionalized Figure Of A Man.) , Dearborn Form Board With Manual:(Contains The Form Board With 12 Designs Of Different Types. Two Wooden Blocks Used As Stimuli Are To Be Placed In Them. Measures Efficiency Skill.) , Pintner-Patterson Five Figures By Rudulf Pintner And Patterson:(With Manual. Contains Eleven Wooden Blocks And Five Figures. The Blocks Are To Be Fitted In Figures. May Be Used To Measure Quick Performance And Learning.) , Pintner-Patterson Short Scale Of Performance Test:(By Rudolf Pintner & Patterson: This Scale Comprises 10 Sub-Tests And Is Useful For Retesting Or Such Other Purposes. Complete With Materials For All 10 Sub-Tests.) , Hanfmann-Kasanin Concept Formation Test:(Consists Of 22 Properly Coloured Wooden Blocks. The Blocks Consist Of 5 Different Colours, 2 Different Heights And Sizes And Six Different Shades. Supplied Witb A Box.) , Reasoning Ability Test (Rat—D)(By L.N. Dube}’ (Englisb): This Test Consists 60 Items. For 12 To 17 Years Students Of Either Sex.) , Rais Concept Formation Test By G.C. Rai (College/Adult Form):(By L.N. Dube}’ (Englisb): This Test Consists 60 Items. For 12 To 17 Years Students Of Either Sex.) , Scientific Thinking Style Questionnaire By P.N. Singh & Ranjana Arora (Hindi/English}(No. Of Item 30. In The Preparation Of The Present Scale All The Six Components, Viz., Amoral, Creative, Developmental, Parsimonious, Testable And Unified Of The Nature Of Scientific Knowledge Have Been Used. Data Collection On The Graduate 1Evel.) , Interview Schedule For Measuring Achievement Oriented Child Rearing Practice By Manju Mehta (English)(: Four Items Related To Each Of The Following Orientation Were Prepared. Activistic-Passivistic-Orientation, Present-Future Orientation, Individualistic-Feministic Orientation. Various Achievement And Independence-Related Demands Were Found To Be Made At Different Age Levels Varying From 2 Years To 15 Years. The Question Used In Second Try Out In The Final Schedule, For Knowing Mothers Standard Of Age For Achievement And Independence Demands. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Pat Anxiety Scale (As- Ck5) By R.B. Cattbbbell, S.K.Krug&I.H.Scheier (English, Indian Print):(This 40 Item Questionnaire Provides A Convenient And Practical Measure Of Anxiety Level. It Is Constituted On The Basis Of 5 Principal 16 P.F. Factors Namely Emotional Instability, Suspiciousness, Guilt Proneness, Low Integration And Tension. It Is Meant For 16 Years And Adults. Approximate Time 15 Min. Standard Scores For Adult, College And High School Population.) , Guidance Need Inventory (Gni) By Sudha Kumari Sharma & Shahwar Fatima Zaidi (English) (No. Of Items 92. Dimensions-Educational, Vocational, Personal, Social, Emotional. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Mental Health Checklist By Pramod Kumar (Hindi/English):(This Check List Consists Of 11 Items. It Measures Mental Health Of Adult Age Range 18-28 Years. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Mental Depression Scale By L.N. Dubey (English):(No. Of Items Are 50. The Age Range 12 To 55 Years. (A)Tesl Booklets (A Pkt. Of 100) (B)Manual (E)Scoring Key) , Suicidal Behaviour Questionnaire By Sheweta Shandilya & Alok Gardia( English):(This Test Measures Four Areas Taps Into Lifetime Suicide Ideation And Or Suicide Attempt, The Frequency Of Suicidal Ideation Over The Past 12 Months, Taps Into The Threat Of Suicidal Attempt, Evaluatesself- Reported Likelihood Of Suicidal Behaviour In The Future. Age Group School And College Students. (A) Test Booklet (A Pit. Of 100)B Manual) , Case Study Test By L.N. Dubey (Hindi/English):((A)Test Booklets (A Pkt. Of 100)(B)Manual) , Medico Psychological Questionnaire By J. Bharat Raj (English)(This Questionnaire Consists Of 50 Items. It Measures Hysteria, Neurasthenia, Anxiety Neurosis, Reaction De Pression, And Obsessive- Compulsivetendency Of Normal And Abnormal Person. It Measures Neurotieism In Terms Of Emotional Adjustment And Emotional Maladjustment. It Is Standardized On College Student Of Both The Sex.) , Introversion-Extraversion Test By M.C. Joshi English):((A)Test Booklets (A Pkt. O£ 100) (B)Instruction And Score Cards (1Pair) , Kundu Introversion- Extroversion Test By R.N. Kundu (English):(A) Test Booklets (A Pkt. Of 100) B)Manual , Personal Efficacy Scale By A.P. Sing & Patiraj Kumari (1991, Hindi/English):(No. Of Items Are 19 For Adult. Norms And Relibaility Are Not Available) , Sex Differentiation Scale By A.P. Singh & Patiraj Kumari (1991, English):(No. Of Items Are 19 For Adult. Norms And Relibaility Are Not Available) , Family I Nvolveoient Inventory By A.P. Singh & Pramila Tiwari (2003, English): (No.Of Items Are 24. Norms Are Not Avalible. For Adults.) , Life Satisfaction Scale Bv A.P. Singh & Pramila Tiwari(2003,Engiish):(No Of Items Are12.Foradults.) , 16 P.F. Test S.D. Kapoor (Hindi/English): Indian Adaplation:(It Has 16 Primary Scales And Other Numerous Derivative Scales. A Test Of Normal Adult Personality The 16 P. F, Form A To E Effectively Measure Levels Of (I) Warmth, (Ii) Intelligence, (Iii) Emotional Maturity, (Iv) Dominance, (V) Impulsivity, (*I) Super Ego Strength, (Vii) Boldness, (Viii) Sensitivity, (Ix) Trust, (X) Imagination, (Xi) Shrewdness, (Xii) Confidence, (Xiii) Radica Alism, (Xiv) Self-Sufficiency, (Xv) Self-Sentiment And (Xvi) Tension. Additional Derived Scales Include Five Second Order Factors— Extraversion, Anxiety, Tough Poise, Independent And Social Control Plus Composite Score For Creativity, Adjustment, Leadership And Numerous Other Criteria Related Scales. Lt Is Widely Used In Industry’And Business For Selection, Placement, Training And Promotion Of Personnel. Lt Also Facilitates Accurate Diagnosis And Effective Treatment. Range 16 Years And Above. Forms A And B Are Equiva Lent Forms Of 187 Items, Untimed, Requires 45-60 Min, Forms C And D Are Equivalent Forms Of 105 Items, Meant For 15+ And Adult, Untiined, Requires 25-30 Min Land Form E Of 128 Items, Is For Low Literates. Manual Also Includes Norms Table. Form A/B/C/D/E (Any One) , Childrens Personality Questionnaire By Porter And Cattell (Cpq-Pc) (English, Indian Print):((The Cpq Measures 14 Primary Traits Useful In Understanding And Evaluating The Course Of Personal, Social And Academic Development, Plus Traits Related To Creativity. Traits Measured By Cpq Include Emotional Stability, Self-Concept Level, Excitability And Apprehension, Scores For Extraversion, Anxietyety And Other Broad Trait Patterns Are Also Obtained As Combination Of The Primary Scales. It Is Meant For Age Groups Between 8-12 Years. Each Form Has 140 Items. Time Required Is 30 To 60 Min Per Form. Minimum Reading Level Is 4Th Standard) , High School Peronality Questionnaire By S.D. Kapoor (English):(Form-A Or B. Jr-Sr. Hspq Measures14 Primary Personality Dimensions -(I) Warmth, (Ii) I Ntelligence, (Iii) Emotional Maturity, (Iv) Excitabilty, (V) Assertiveness, (Vi) Enthusiastic,(Vii) Su Per Ego Strength, (Viii) Venturesome, (Ix) Dependent, (X) Individualistic (Xi) Depressive, (Zii) Self Sufficient, (Xiii) Controlled, (Xiv) Tense. It Contains T42 Iteras Ia Each Form And Is Meant For Age 12-18 Years. Time Required Is 40 Min. (A)Test Booklets (A Pkt. Of 20) (B)Test Profile (A Pkt. Of 100) (C)Manual (D)Answer Sheets (A Pkl. Of 100) (E)Scoring Key) , Adolescent Problems Scale By H.D. Badami (English}(: The Present Problem Inventory Is College Level And Post-Graduate Level. No. Of Items 265. In This Test 9 Areas Measuring- 1. Physical Health And Fitness, 2. Self And Self-Image, 3.Economic And Mate Rial Facilities, 4. Friendship, Sex And Marriage, 5.Family, 6. Social, 7. Educational, 8. Vocational, 9. Custom, Morality & Religion. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Sex-Role Inventory By Madhu Asthana And O.P. Chaudhary (Hindi/English (No. Of Items Are 60. (A)Manual (B)Test Booklets (A Pkt. Of 100) (C)Scoring Key) , Eysenck Personality Inventory By H.J. Eysenck And Sybil B.G. Eysenck (English} (: (A)Test Booklets (A Pkt. Of 100)(B)Manual) , Eysenck Personality Inventory (Epi) By G.P. Thakur (English):(No. Of Items Are 57. (A)Test Booklets (A Pki. Of 100) (B)Manual (C)Scoring Key) , Temperament Scale (For Chidlren) By J.D. Murjani (Hindi/English):)(For Age Group 8 14 Years. No. Of Items 30. Ten Dimensions Are Measuring Sociability, Tolerance, Aggressiveness, Warmth,Responsibility, Impulsivity, Cheerfulness, Vigorous, Co- Operativeness, Persistence. (A)Test Booklets (A Pit. Of 100) (B)Manual) , The Inferiority Questionnaire By G.C. Pati (English)(It Is A 20 Item Test.Validity Coefficient Against ’Self-Rating’ Is 0.717 And Reliability (Test-Retest) Is 0.920. Scheme For Qualitative Interpretation Of Scores Provided. (A)Test Sheets (A Pkt. Of 100) (B}Manual) , Coping Strategies Test (2001) By A.K. Srivastava (Hindi/English):(Age Group 11 To 18 Years. No. Of Item Are 50. Five Major Categories Measure - Behavioural-Approach, Cognitive-Apprroach, Cognitive- Behavioural Approach, Behavioural- Avoidance,Cognitive Avoidance. (A)Test Booklets (A Pkt. Of 100)(B)Manuai) , Aggression Questionnaire By G.C. Pati (Hindi/English):(It Is Composed Of 16 Multiple Alternative Type Of Answer. Its Ratio Is 0.71 And Validity Against External Criterion Is 0.828. Scheme For Qualitative Interpretali On Of Scores Is Provided. The Questionnaire Consists Of 16 Questions. (A)Test Booklets (A Pkt. Of 100} (B)Manual) , The Dependence Proneness Scale By Jai B.P. Sinha (Hindi/Englisb):(There Are Four Areas - Affection- Affiliation, Lack Of Internal Control, Evading Responsibility And Conformity; To Be Rated On A 5 Point Likert Scale. Its Reliability Coefficient Is .94. Individual Administration Is Advised. Validity Has Been Established Against Many Experimental Situations. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Self-Esteem Questionnaire By Minakshi Biswal (English)(No. Of Items 50. Age Group 15-25 Years. It Can Be Used For Any Behavioural Research Concerning Self Esteem, Survey Purpose/For Comparison Of Population. It Gives A Quick Measure Of Self-Esteem For Experimental Purposes. It Is Suitable For Group Administration As Well As For Individual Testing. The Test Is Developed And Standardized On An Indian Sample. (A) Test Booklets (A Pkl. Of 100 B) Manual) (1 Pair) (D)Manual) , The Self-Confidence (S-C) Scale By M. Basavanna (English):(It Is A 100 Item Scale In T & F Type. It Is Designed To Estimate The Level Of Self-Confidence Among Adolescents And Adults. Corrected Split-Half Reliability Is 0.94. Validity In The Form Of Item Validity And Against Other Experimental Indices Is Established. The Test Booktlet Is Reusable. (A)Test Booklets (A Pkt. Of 20) (B)Answer Sheets (A Pkt. Of 100) (C)Scoring Key (1 Pair) (D)Manual) , Self-Esteem For Children By Anand Kumar (English):(A Set For Children Contains 50 Items And The Following 4 Subscales: 1.General Self-Esteem, 2. Social Self- Esteem, 3. Academic Self-Esteem, 4. Parental Self-Es Teem. Age Group 8 To 15 Years. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Self-Concept Inventory (Adults) By Beena Shah (English):(No. Of Items Are 64. Age Group 21 To 50 Years. 10 Dimensions Measured In This Test Are - 1. Social Self Concept, 2. Emotional Self-Concept, 3. Physical Self-Concept, 4. Cognitive Self-Concept, 5. Aesthetic Self-Concept, 6.Political Self-Concept, 7. Job Related Self-Concept, 8. Self-Coafideoce, 9. Beliefs And Traditions, 10. Personality Traits. (A)Test Booklets (A Pkt. Of 100) (B)Manual) , Personality Assessment Ranking Method By N.K.Jain (English)((A}Ranking Sheets (A Pkt. Of 100)(B)Manuai) , Multi-Dimensional Assessment Of Personality Scale (Map Series) By Sanjay Vohra:(Map Is A Series Of Tests Ranging From Children Of Primary Level To Normal Adult Personality. Lt Is Used To Analyze/Report Individual Differences In Personality. The Map Series Has Four Forms For Different Levels (Map Form A, T, C And P) , Sentence Completion Test By L.N. Dubey & Archana Dubey (English):(This Test Consists Of 50 Items. It Maeasures Certain Personality Traits — Sociability, Self Confidence And Ambitions. All The Sentences Are So Framed That They Lead To Reveal The Positive Or Negative Aspects Related To Ones Trait. Age Range 14 To 19 Years. (A)Test Booklets (A Pkt. Of 100)(B)Manual0 , Draw-A-Man Test By Pramila Pathak (Age 2.5 To 16 Years.( , Thematic Apperception Test With Manual By H.A. Murray (Original)(Age 14+ Years): , Indian Adpatation Of Children Apperception Test With Manual:((Cat) By Uma Choudhary. Age 4 To 10 Year.) , Indian Adpatation Of Thematic Apperception Test With Manual (Tat) By Uma Choudhary(: Age 15+ No. Of Cards 14 With One Blank:) , Children Apperception Test By Bellack & Bellack (Original) (Cat):(The Cat Consists Of Ten Pictures Depicting Animals In Various Situations. It Is Used With Children Of Both The Sexes Primarily Between The Ages Of 3 To 10 For Maximal Usefulness. It Is Designed To Facilitate Understanding Of A Childs Relationship To His Most Important Figures And Drives. A) Animal Figure B) Human Figure C) Supplementary) , Rorschach Inkblot Test:(With Psychodiagnostic Plates, Record Blank, Location Chart And Manual By Herman Rorschach.) , Indian Adpatation Of Rosenzweig Picture Frustraction Test (Children) By Udai Pareek:(English)(: For Age Group 4 To 13. (A)Test Booklets (A Pkt. Of 20) (B)Record Sheets (A Pkt. Of 50) (C)Manual) , Peer Pressure Scale By Kusum Tyagi & Nidhi Gupta (English)(: Age Group 12 19 Year. No. Of Items 50. This Test Measures 5 Areas - 1. Interpersonal Relationsbip, 2. Agreeableness, 3. Economic Pressure,4. Academic/Scholastic And 5. Consientioun Sess. (A)Test Booklets (A Pitt. Of 100) (B)Manual) , Tweezer Type Dexterity Test:(Teak Wood Base With Rust Proof Metal Square Top Witb 100 Holes. 100 Needles Provided With A Fine Tweezer.) , Manual Dexterity Test:(Plywood Made With Sockets And 60 Pegs. Painted Or Polished And Fine Finish.) , Finger Dexterity Test :(Box Type.) , Threading Test:(The Device Is Employed In Testing The Speed And Dexterity In Finger Movement. The Time Required To Pass A Thread Through An Eye’ Of 33 Rods, Three In A Row And 11 Rows, Is Measured. The Quality Of Performance Can Also Be Checked Easily.) , Complete Minnesota Dexterity Test:(This Test Measures Simple Hand-Eye Coordination And Gross Motor Skills. It Consists Of A Battery Of Five Tests: Placing, Turning, Displacing, One- Hand Turning And Placing, And Two- Hand Turning And Placing. This Test Comes Complete With Two Folding Pegboards, 60 Blocks.) , Whipples Tapping Board: (This Apparatus Demonstrates One Of The Most Elementary Psychomotor Skills. The Task Is Simply To Tap The Stainless Steel Plates As Rapidly As Possible. Designed For Versatility And Durability, This Unit May Be Used To Demonstrate A Number Of Important Principles) , Hand Coordination Test (Electrically Operated):(Used For Teaming Experiments Of Two Hand Coordination, Consists Of Mechanical Device Permitting Horizontal And Vertical Movements Of A Pin Or A Pencil Through Slot Ted Design. Time And Errors Are Counted. Using Impulse Counter Cumulative Record Of Errors Can Be Assessed. 389. Minnesota Rate Of Placin) , Eye Hand Co-Ordination Test (Drever & Collins Model):(A Semi-Circular Hand Plywood Is Covered On One Side By An Iron Sheet. A Scale Is Mounted On Which The Rider Is Moved On Both The Sides Except The Blind Zones. The Subject Sits With His Chin Resting On Chin Stand. Fine Finish With Pointer And The Rider.) , Speed And Accuracy Test (English):((A)Numerical Sheets (A Pad Of 100)(B)Alphabetical Sheets (A Pad Of 100) (E)Manual) , Social Maturity Scale By J. Bharatraj (English):(For Age Level From 0 To 15 Years. A) Test Booklets (A Pkt. Of 100) B)Manual) , Social Cognition By N.K.Jain (English):((A)Stimulus Material (A Pkt. Of 100)(B)Scoring Template (A Pkt. Of 100) (C)Manual) , Environmental Awareness Questionnaire By Sunita Singh (Hindi/English)(:For Secondary Level To P.G. Level. The Questionnaire Contains 32 Items From Different Areas Related To Measuring Of Environment, Case And Effect Of Pollution And Prevention. It Has High Reliability (0.87). The Validity Has Been Ensured Through Experts Opinion. Percentage Score Norms Have Been Provided. (A) Test Booklets , Inter Personal Attraction By Ripunjay Deo Singh & Vikas Kumar (Hindi/English):(No. Of Items Are 34. Dimension/Factors Are 1. Interactional Factors, 2. Personal Factors, 3. Personality Factors, 4. Physical Factors, 5. Situdational) , Rumour Analysis By N.K.Jain (English)((A)Stimuius Material (A Pkt. Of 100) (B)Scoring Template (A Pkt. Of 100) (C)Manual) , Sociometric Choice Test By Meera Joshi & Jagdish Pandey (English):(This Test Records Interpersonal Attractions Among The Members Of A Group. The Test Should Be Used With A Group Of Persons Who Have Been Together Long Enough To Be Acquainted With One Aaother, Such As In A Class, In A Factory, Club, Etc. Each Individual Is Asked To Choose Five Group Members With Whom He Would Like Most And Also Dislike Most To Study, Play, Sit Or Work, Lunch And Walk. The Names Are To Be Written According To Their Choice Positions. The Choices May Be Interpreted Either In Manner Of A Sociogram Or On The Basis Of Ratings On The Preference Scale Continuum. (A)Test Booklets (A Pkt. Of 100) , Impression Formation By Photographs By Meera Joshi & J. Pandey (Hindi/English):((A)Cards (B)Answer Sheets (A Pkt. Of 100) (C)Manuai) , Aids Awareness Questionnaire By Madhu Asthana (Hindi/English):Lthy Personality. A) Test Booklets (A Pkt. Of 100) B) Manual((A)Manual (B)Test Booklets (A Pkt. Of 100)) , Indian Adaptation Of Hutts Bender Gestalt Test For Adults By C.B. Dwivedi &Subhara Banerjee:(This Adaptation Provides Scoring Instructions For 17 Pathological And For The Adienceabience Scale. It Is Highly Useful For A Quick Understanding And Screening Of Psychopathological Cases. Normative Data Have Been Provided For The Mentioned 17 Pathological And Adolescent-Abience Scale Separately. (A)Manual (B)Test Cards (Per Set) (E)Lndividuai Response Sheet (A Piit. Of 100) (D)Test Booklets (A Pkt. Of 100) , Occupational Role Stress Inventory By Udai Pareek (English):((A)Test Booklets (A Pitt. Of 100)(B)Manuai) , Job Anxiety Scale By M.M. Sinha And A.K. Srivastava (English):(The Scale Comprises 80 Items Which Reveals Employees Anxiety Being Manifested In The Context Of Following Seven Components Of The Job (1) Security- Job Security And Safety, (2) Recognition, (3) Human Relations At Work, (4) Reward And Punishment, (5) Self-Esteem, State Punishment, (6) Self-Esteem, Self-Image, (7) Future Prospects, (8) Capacity To Work. The Scale May Be Administered To The Employees Operating In Production As Well As Non Production Organisations. The Scale May Be Conveniently Used For Research, Survey And Diagnostic Purposes. Split-Half Reliability Is 0.92, And Test-Retest Reliability Is 0.94. The Test Was Validated Against Sinha Anxiety Scale (R-0.54), Sarasons General Anaiety Scale (R-0.56), Taylors Manifest Anxiety Scale (R 0.48). (A)Test Booklets (A Pkt. Of 100) (B)Manual ) , Creative Behaviour Questionnaire By A.P. Singh & L.K. Mishra (2009, English)(No. Of Items Are 13 For Manager) , Intrinsic Work Motivation Questionnaire By A.P. Sngh& L.K. Mishra (2009, English):(No. Of Items Are 12. For Employee.) , Audio Visual Aids Chart Types Of Modern Indian Education . Models Of Teaching History And Development Of Indian Education School Of Psychology Theories Of Personality Theories Of Intelligence Theories Of Learning Major Schools Of Philosophy Schools Of Indian Philosophy Physiological Charts: A Set Of 7 - Eve, Ear, Brain, Skeleton, Nervous System, Human Body, Blood Circulation) , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) David Weehsler , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) H.I Eysenck, , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Kuri Lewin , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Alfred Binet , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Wilhelm Wundt , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Gordon Allpor , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) B.F. Skinner , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Sigmund Freud , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Edward L.Throndihe , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Ivan P. Paxlov , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Jean Piaget, , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Wolfiang Kohler , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Edwin Guthrie , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Carl Gustav’ Jung , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Raymond Bernard Catteii , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) John B. Watson , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Herman Rorschach , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Carl Rogers , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Hermann Ebbinghaus , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Abraham Maslow , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Aristotle , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Erin H. Erikson , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Rollo May , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Albert Bandura , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Lewis Terman , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Henry Murray , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Roberi Pluichik , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Alfred Adler , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Hefimann Von Helinholtze , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) William James , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) John Dewey , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Herbert Spencer , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) John Friedrich Herbart , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Jean Jacques Rousseau , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Johann Heinrich Pestolozzi , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Friedrich Frobel , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Max Wertheimer , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Rene Descartes , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Plato , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Socrates , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Maria Montessori , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) B.Russell , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Francis Galton , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) William Mcdougall , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Edward C. Tolman , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Louis Leon Thurstone , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) William Heard Kilpatrick , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Gastav Theodor Fechner , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Ernst H. Weber , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Charles Robert Darwin , Photographs Of Eminent Foreign Psychologists/Educationists (Coloured Size 11 X 17) Jerome Seymour Bruner , Blind Goggles , Metronome:With Bell (Imported)
Contract Date: Jun 27, 2026 Contract Value : 4.95 Lakh
Local Bodies No of Bidders 5
12.
Chemicals and Fertilizers #11371335 AOC
Bids Are Invited For Spares For Jrs Make Bagging Machine Total Quantity : 117; 1 711803138 PAN SUPPORT BRACKET FOR LOAD CELL ASSEMBLY OF UBM-85 BAGGING MACHINE MAKE : JASUBHAI ENGINEERING PVT. LTD 2 Number 2 075123132 SPARES FOR BAGGING MACHINE Equipment : JRS BAGGING MACHINE Model : UBM-85 Make : JRS Supplier : JASUBHAI MATERIAL HANDLING SYSTEMS PVT LTD Flexible Jaw Connection (Rubber) Area : Bag Holding 30 Number 3 828883910 SWINGING BAFFLE FOR INLET ASSEMBLY (SPOUT ASSEMBLY) OF UBM -85 BAGGING MACHINE MAKE : JASUBHAI ENGINEERING PVT.LTD 3 Number 4 841101004 DIGITAL BAG COUNTER Mounting : Flush panel mounting Panel cut out size: 29mm x 71mm. (+/- 2mm) Display : Digital LED display (Seven segment) Display size : 6 Digit, 0. 3 inch Height Display Colour : Red. Number of input channels: One Input : Potential free contact Range : 999999 Counts. Counting direction : Upward Reset Option : Required i) On front panel. ii) Remote reset ( Via rear terminals) Output : Not required Power Supply : 24 VDC Power Comsumption : 5 VA max. Temperature : 20 to 50 Deg.C Humidity : 95% RH. Housing : Flame retardent Plastic. Protection Level: IP 65 Weight : Approx 110 grams 4 Number Please submit your offer for supply of the following items as per the instructions, technical specifications and other terms and conditions specified herein/ attached. Note: 1. The delivery period mentioned in the BoQ is our indicative requirement. You may offer your earliest delivery period. 2. Please refer our above referred enquiry number in all correspondence. 5 841200142 PNEUMATIC CYLINDER, 40 x 100 STROKE WITH CT(FEMALE)WITH MOUNTING, PISTON ROD END BLOCK AND PISTON ROD END PIN FOR DRIBBLE VALVE, PISTON SHAFT THREAD-NPT 6 Number 6 841200143 PNEUMATIC CYLINDER, 40 x 100 STROKE WITH RC MOUNTING, PISTON ROD END BLOCK AND PISTON ROD END PIN, FOR BOMB PAN DOOR, PISTON SHAFT THREAD-NPT 8 Number 7 841200160 PNEUMATIC CYLINDER, 80 x 60 STROKE WITH CT WITH MOUNTING, PISTON ROD END BLOCK AND PISTON ROD END PIN, FOR BB80, PISTON SHAFT THREAD-NPT 8 Number 8 841200184 REPAIR KIT FOR 80 x 60 CT CYLINDER INCLUDING CUP, GLAND O-RING, GUIDE AND WIPER 10 Set 9 841200201 Relay Board for JASUBHAI JB07 Bagging Machine Controller / Control Panel 5 Number 10 841200202 PLC Relay for JASUBHAI JB07 Bagging Machine Controller / Control Panel 5 Number 11 841200203 Timer for JASUBHAI JB07 Bagging Machine Controller / Control Panel 3 Number 12 841200204 EMI Filter for JASUBHAI JB07 Bagging Machine Controller / Control Panel 3 Number 13 841200241 REPAIR KIT FOR 40 x 100 CT CYLINDER INCLUDING CUP, GLAND O-RING, GUIDE AND WIPER 6 Number 14 841200242 REPAIR KIT FOR 40 x 100 RC CYLINDER INCLUDING CUP, GLAND O-RING, GUIDE AND WIPER 10 Number 15 841200251 Complete Pneumatic BB – 80 Bag Holder Assembly with 2 Nos. Cylinder, Bag Feeler Sensor, Bag Clamp Sensor Assembly Material of construction : SS (for JASUBHAI BAG. MACHINE- UBM 85) 1 Number 16 841200256 Spare OCP indicator for UBM 85 Net weighing/Bagging Machine Make : Jasubhai Engg. Pvt Ltd Model: JB RD 01 4 Number 17 841200257 SS 316 WEIGH PAN with CYLINDERS (for JASUBHAI BAGGING MACHINE-UBM 85) 1 Number 18 841200501 SMPS for JASUBHAI JB07 Bagging Machine Controller / Control Panel 2 Number 19 841467215 INDUCTIVE SLOT SENSOR MAKE : PEPPERL + FUCHS MODEL : SJ 15 - E2 SLOT WIDTH : 15 MM OPERATING VOLTAGE: 10-30 VDC CONNECTION TYPE : 2 METER PVC CABLE PROTECTION : IP 67 6 Numbe
Contract Date: Ref. Documents Contract Value : 10.60 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 2.10 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Maharashtra View Result →
14.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
15.
Housing Urban and Rular Development #11324076 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Replacement Of Damaged/Choked Suction Pipe Line In Septic Ot And Surgery Ot Inside Emergency Ot Of Gmch, Jammu Along With Allied Works. Mhdj/E-Nit 59 Of 2026-27 Dated: 01.06.2026 Due : 10.06.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Replacement Of Damaged/Chokedsuction Pipe Line In Septic Ot And Surgery Ot Inside Emergency Ot Of Gmch, Jammu Along With Allied Works By Way Ofproviding And Laying Of Medical Grade Copper Pipe For Medical Gases (Air, Oxygen And Vacuum) As Per En 13348:2001, (Medical Grade), Solid Drawn, Seamless, De-Oxidized, Non-Arsenical, Half-Hard Fully De-Greased (Designated To R250) Along With All Allied Works Necessary For Installation, Testing And Commissioning Of Pipeline System. It Should Conform And Meet With The Latest Bsen 13348:2001 Standard. Chemical Compositions As Per Cudhp To 1190-1 And Cwo 24A To En 1412. Maximum Total Carbon Content 0.20 Mg/Dms. The Pipes Shall Be Accompanied With Manufactures Test Certificate For The Physical Properties & Chemical Composition. The Copper Pipe Should Be Suitably Embossed With The Manufacturingname/Logo (Make:Mexflow/Mandev/Metalalloy) Specifications Of Medical Copper Pipe Is As Below: - 22Mm Od X 0.9Mm Thick (Payment Shall Be Made As Per Actual Measurement) , Replacement Of Damaged/Chokedsuction Pipe Line In Septic Ot And Surgery Ot Inside Emergency Ot Of Gmch, Jammu Along With Allied Works By Way Ofproviding And Laying Of Medical Grade Copper Pipe For Medical Gases (Air, Oxygen And Vacuum) As Per En 13348:2001, (Medical Grade), Solid Drawn, Seamless, De-Oxidized, Non-Arsenical, Half-Hard Fully De-Greased (Designated To R250) Along With All Allied Works Necessary For Installation, Testing And Commissioning Of Pipeline System. It Should Conform And Meet With The Latest Bsen 13348:2001 Standard. Chemical Compositions As Per Cudhp To 1190-1 And Cwo 24A To En 1412. Maximum Total Carbon Content 0.20 Mg/Dms. The Pipes Shall Be Accompanied With Manufactures Test Certificate For The Physical Properties & Chemical Composition. The Copper Pipe Should Be Suitably Embossed With The Manufacturingname/Logo (Make:Mexflow/Mandev/Metalalloy) Specifications Of Medical Copper Pipe Is As Below: - 15Mm Od X 0.9 Mm Thick (Payment Shall Be Made As Per Actual Measurement) , Replacement Of Damaged Valve By Way Of Providing And Fitting Of Ball Valves With Brass Fitting For Regulation Of Medical Gases (Vacuum) Of Size As Below:- (Complete Job Includes Labour Charges, Transportation Charges, All Kinds Of Taxes Etc. 22Mm , Replacement Of Damaged Medical Gas Terminal Units/Gas Outlet Points (B.S.Type) Septic Ot And Surgery Ot Inside Emergency Ot Of Gmch, Jammu By Way Of Providing & Fitting Of New Gas Outlet Point Of Make Aktiv/Mps/Tri-Tech. The Medical Gas Outlet Point Should Have Proper Colour Coding As Per The Gas Being Used And It Should Also Have Integral Check Valve To Allow Removal Of Housing, Front Fascia And Socket Assembly For Maintenance Without Closing Down The Entire Pipeline And The Medical Gas Outlet Points Should Be Ce Certified And Shall Confirm To Latest Standard Of Health Care Facilities. The Complete Job Includes Cost Of Material, All Handling & Labour Charges. Vacuum , Providing And Fitting Of Suction Jars Of Nationally Reputed Make Aktiv/Mps/Tri-Tech(Complete With Probe & High Pr. Hose) For Emergency Ot Of Gmch, Jammu. It Should Be Duly Ce Certified And Comply With Latest Health Care Standards. Vacuum Collection Jar Should Be Of High Quality Durable Receiver Jars For Suction System, Strong Polycarbonate Material And Autoclavable At 121 Degree Centigrade For 15 Minutes Without Degradation. The Vacuum Regulators Should Have Dial Gauge, On/Off Switch And Valve Control Knob Along With High Pressure Tube And Probe (B.S.Type). Complete Set. The Complete Job Includes Cost Of Material, Skilled Labour Charges, All Unforeseen Items/Jobs Required For The Completion Of Job And All Taxes Etc. Complete Job. Suction Jar Of 2000 Ml Capacity Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
16.
Educational and Research Institute #11318501 Technical Bid
Rate Contract For Supply Of Consumables/Non-Consumables For The Department Of Plastic Surgery , Consumables , Adhesive Hydrocellular Foam Dressing - Size: 12.5 Cm X 12.5 Cm , Adhesive Hydrocellular Foam Sacrum Dressing - Size: 17 Cm X 17 Cm , Adhesion Barrier Film Which Is Translucent And Hydrophilic Adhesion Barrier Made Of Sodium Hyaluronate And Carboxymethylcellulose - Size:5 Inx 6 In , Adhesion Barrier Film Which Is Translucent And Hydrophilic Adhesion Barrier Made Of Sodium Hyaluronate And Carboxymethylcellulose - Size:3 Inx5 In , Barrier Foam Dressing (Sterile) 10Cm X 10Cm , Barrier Gauze Dressing (Sterile) , Centella Asiatica, Silver Oxide And Silk Powder - 50Gm , Centella Asiatica, Silver Oxide And Silk Ointment - 25Gm , Centrifuge Tubes Polypropylene Cap (Sterile) - 15 Ml , Chlorhexidine Gauze Dressing Size 10 X 10Cm , Chlorhexidine Gauze Dressing Size 10 X 30Cm , Cockup Splint , Colloidal Silver Solution - Pre-Cleaning Solution Containing Colloidal Silver - 60 Ml , Compression Bandage , Cotton Crepe Bandage Size - 10Cm X 4M , Cotton Crepe Bandage Size - 15Cm X 4M , Fiber Glass Cast Tape For Limb Splint - Size: 7.5Cm , Fiber Glass Cast Tape For Limb Splint - Size: 10Cm , Fiber Glass Cast Tape For Limb Splint - Size: 15Cm , Finger Splint , G Bone(Modified Hydroxyapatite Granules And Blocks) , Gentamicin In Collagen Base Gel For Wound Healing - 30Gm , Hemostat To Stop Bleeding For Arterial Haemorrhages Comprised Of Agar And Bovine Factor Proteins (Iia, Viia, Xia And Xa) And Acts As A Catalyst In The Clot Formation Process - Pack Size 3Ml Vial , Ionic Silver Solution , Kaolin Impregnated X-Ray Detectable Hemostatic Dressing -Size:10 Cm X 10 Cm , Kaolin Impregnated Vaccum Packed Hemostatic Dressing -Size: 7.5 Cm X 3.7 M, X-Ray Detectable Strip , Kaolin Impregnated Ems Rolled Gauze Hemostatic Dressing -Size:7.5 Cm X 1.2 M , Low Adherent, Absorbent Wound Dressing - Size: 10Cm X 10Cm , Leur Lock Syringe (Disposable) - 2 Ml , Leur Lock Syringe (Disposable) - 5 Ml , Leur Lock Syringe (Disposable) - 20 Ml , Multi-Layered Design Incorporating Hydrocellular Foam With Hyper-Absorbent Lock Away Core Having Five Layers Comprising Of Masking Layer, Silicon Layer,And Polyurethane Breathable Top-Size: 12.9 X 12.9 Cm , Multi-Layered Design Incorporating Hydrocellular Foam With Hyper-Absorbent Lock Away Core Having Five Layers Comprising Of Masking Layer, Silicon Layer,And Polyurethane Breathable Top- Size: 15.4 X 15.4 Cm , Non Adhesive Hydrocellular Foam Dressing - Size: 10Cm X 10Cm , Non-Woven Island Wound Dressing (Non Woven Adhesive Sheet With Absorbent Pad) Size 10Cm X 8Cm , Non-Woven Island Wound Dressing (Non Woven Adhesive Sheet With Absorbent Pad) Size 10Cm X 20Cm , Non-Woven Island Wound Dressing (Non Woven Adhesive Sheet With Absorbent Pad) Size15cm X 8Cm , Orthopaedic Cast Padding-Size 10Cm X 3M , Orthopaedic Cast Padding-Size 15Cm X 3M , Oxidized Regenerated Cellulose, Bactericidal By Ph Action, Absorbable Topicalhemostat - Standard Size: 2 X 3. Approved By Ce , Oxidized Regenerated Cellulose, Bactericidal By Ph Action, Absorbable Topicalhemostat -Size 1 X 2 Fibrillar Form. Approved By Ce , Oxidized Regenerated Cellulose, Bactericidal By Ph Action, Absorbable Topicalhemostat -Size 1 X 1 Woven Form. Approved By Ce , Paraffin Gauze Dressingsize 10 X 10Cm , Paraffin Gauze Dressingsize 15 Cm X 2M , Polyester Wound Contact Layer With Central Cotton Absorbent Layer And Out Hydrophobic Non-Woven Layer. Low Adherent, Absorbent Wound Dressing -Size: 10 Cm X 10 Cm , Polyester Wound Contact Layer With Central Cotton Absorbent Layer And Out Hydrophobic Non-Woven Layer. Low Adherent, Absorbent Wound Dressing -Size: 10 Cm X 20 Cm , Polyester Wound Contact Layer With Central Cotton Absorbent Layer And Out Hydrophobic Non-Woven Layer. Low Adherent, Absorbent Wound Dressing-Size: 50 Cm X 7 Mtr Roll (Unsterile) , Pre-Cut Synthetic Splint System -Size: 10 X 40Cm , Pre-Cut Synthetic Splint System -Size: 12.5 X 76Cm , Pure Type I Bovine Collagen Particles , Rae Endotracheal Tubes (Oral Curved) (Pvc) Cuffed -Size 3.0, 3.5, 4.0, 4.5, 5.0, 5.5 (Set Of All Sizes) (50 Sets) , Rae Endotracheal Tubes (Oral Curved) (Pvc) Non Cuffed - Size 3.0, 3.5, 4.0, 4.5, 5.0, 5.5(Set Of All Sizes) (50 Sets) , Rae Endotracheal Tubes (Oral Curved) (Pvc) Cuffed -Size 6.0, 6.5, 7, 7.5 (Set Of All Sizes) (50 Sets) , Rae Endotracheal Tubes (Oral Curved) (Pvc) Noncuffed - Size 6.0, 6.5, 7, 7.5 (Set Of All Sizes) (50 Sets) , Recombiant Human Epidermal Growth Factor 150Ug/G Gel , Recombiant Human Epidermal Growth Factor 60Ug/G Gel , Silicone Gel In Tubes For Scar Treatment - 10Gm , Sterile Dehydrated Human Amnion Chorion And Polyhexamethylene Biguanide Powder (6Gm) , Sterile Dehydrated Human Umbilical Cord Derived Membrane Allograft-Size:5Cm X 3Cm , Sterile Dehydrated Human Amnion Chorion Membrane With Polyhexamethylene Biguanide- Size: 7Cm X 7Cm , Sterile Dehydrated Human Amnion Chorion Membrane With Polyhexamethylene Biguanide- Size:11M X 7Cm , Skin Marking Pen , Staple Remover , Temporary Biosynthetic Skin Dressingconstructed Of A Silicone Film Bonded To A Cross-Linked Dermal Collagen Coated Nylon Fabric-Size:13 X 13 Cm , Transparent Adhesive Dressing -Size: 60 X 45Cm , Type I Collagen Particles With Mupirocin Ip 2% W/W And Metronidazoleip 1% W/W , Universal Laser Eye Safety Goggles , Varicose Vein Stockings , Wd 40 Lubricant , Pla Reel 1Kg For 3D Printer Medical Grade , Arch Bar For Dental Reconstruction (German Silver/Stainless Steel) , External Fixator Set For Fingers , Hunters Rod (Silicon Rods) For Tendon Repairs , Silicon Block , Tendon Spacer , Nasalimplantdorsal , Chin Implant Adjustable , Cheek Implant (Zygomatic)Left , Cheek Implant (Zygomatic)Right , Round Loop Electrode For Radio Frequency Surgery - Fine Wire , Round Loop Electrode For Radio Frequency Surgery - Regular Wire , Triangularloop Electrode For Radio Frequency Surgery - Fine Wire , Triangular Loop Electrode For Radio Frequency Surgery - Regularwire , Needle Electrode For Radio Frequency Surgery - Fine Wire , Needle Electrode For Radio Frequency Surgery - Superfine Wire , Needle Electrode For Radio Frequency Surgery - Regular Wire , Bipolar Forceps Straight Compatible For Alan And Erbe Diathermy Machinesize 6- 0.2 Mm , Bipolar Forceps Straight Compatible For Alan And Erbe Diathermy Machinesize5 - 0.1 Mm , Bipolar Non-Stick Angled Forceps Compatible For Alan And Erbe Diathermy Machine Size 6 - 0.2 Mm , Bipolar Non-Stick Forceps 4 Fine Tip (1Mm) Compatible For Alan And Erbediathermy Machine , Bipolar Connecting Cable, Vio, Icc, Acc (2-Pin 22 Mm), 4 M For Bipolar Forceps With European Flat Plugcompatible For Alan And Erbe Diathermy , Cable For Bipolar Forceps Compatible For Alan And Erbe , Disposable Adult Patient Plate Compatible For Alan And Erbe Diathermypediatric , Disposable Handswitch Pencil For Monopolar Diathermy Compatible With Alan And Erbe Models , Disposable Neutral Plate - Adult , Disposable Neutral Plate - Pediatric , Ellman Company Radio Frequency Cable , Ellman Company Radio Frequency Plate , Spatula Electrode Compatible For Alan And Erbe Diathermy , Silicon Cord For Insulated Bipolar Forceps (Autoclavable) , Surgical Gloves: Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated Siliconated. Size : 7.5 , Surgical Gloves: Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated Siliconated. Size : 7 , Surgical Gloves: Polyurethane Inner Coating With Textured External Surface And Dark Coloured To Prevent Reflective Glare. Internal Surface Should Have Powder Free, Polymer Coated Siliconated. Size : 6.5 , Eutatic Mixture Of Local Anesthetic (Prilocain + Lignocain) Tubes , Beaver Needle Blade 1.5 Mm Cutting Edge, 3 Per Box , Bd Beaver Mini - Blade Knife- Straight, Sharp All Around 180° Cutting Surface, Double Level Blade , Beaver Mini-Blade Angled 60°, Sharp All Around 180° Cutting Surface, Double Level Blade , Multi Fire Vascular Clip Applicator For Liga Clip (5 Mm) , Cramer Wire - Small2 , Cramer Wire - Medium 3 , Cramer Wire - Large 4 , Cramer Wire- Extra Large 6 , Thermoplastic Perforated Sheet For Preparing Malleable And Strong Splint Size:45Cm X 60Cm X 5 Mm Thickness , Hydrojet Cannula , Dr. Lite Bulb Holder , Bulb 24 V 150 W , Ear Suction Canula (Luer Lock Fitting Blunt Point) With Connector16 G, 17 G& 18 G , Wound Protector / Retractor Device 2-4 Cms , Wound Protector / Retractor Device 2.5-6 Cms , Wound Protector / Retractor Device 5-9 Cms , Alar Retractor , Bone Marrow Aspiration Cannula 16 Gauge , Liposuction Tubings With Adaptor Suitable For Liposuction Model Infusa Plus , Paediatric Cuff For Zimmer Tourniquet Size 8 , Paediatric Cuff For Zimmer Tourniquet Size 12 , Ear Tip For Impedence Suitable For Gsi 38 Auto Tymp , Colorado Needles– 76Mm + 10Mm Tip Length , Colorado Needles– 76Mm + 10Mm Tip + 3Mm 45° Uninsulated Tip Length , Colorado Needles– 178Mm + 10Mm Tip + 3Mm 45° Uninsulated Tip Length , Colorado Micro Dissection Needles –3 Cm Straight (3/32 Sleeve) , Nano Crystaline Silver Gel 0.002% W/W , Hair Growth Serum - 60 Ml , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 5X5 Cm , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 10X10 Cm , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 10X20 Cm , Synthetic Biodegradable Temporizing Tri-Layered Open Cell Foam Matrix Made From Biodegradable Polyurethane. Converts Macro Wounds Into Organised Micro Wounds. Regenerates Neodermis And Neovascularization. Size: 20X40 Cm , Aqua Spray Aerosol ( With Bag-On-Valve Technology) For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate And Sodium Chloride And Purified Water 95.85%. Delivery Mechanism Is Continous Aerosol Creating & Emptying 100% Of Product From Container With No Contamination - 50 Gm , Aqua Spray Aerosol ( With Bag-On-Valve Technology) For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate And Sodium Chloride And Purified Water 95.85%. Delivery Mechanism Is Continous Aerosol Creating & Emptying 100% Of Product From Container With No Contamination - 100 Gm , Dressing Impregnated With Electrochemically Solutionreleasing Active Chlorine Released From Hypochlorous Acid 0.003% At 100 Ppm And Sodium Hypochlorite Solution With Neutral Ph, Non-Toxic, Human Skin Friendly Madefor Bactericidal, Fungicidal Action, Ce Certified & Fda Approved. Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% & Gauze - Size 10* 10 Cm , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 100 Ml Spray , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 250 Ml Spray , Electrochemical Solutionreleasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 250 Ml Cap Bottle , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 500 Ml Cap Bottle , Electrochemical Solutionreleasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 1000Ml Cap Bottle , Electrochemical Solutionreleasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation -500 Ml Irrigation Bag With Closed System (Self Collapsible & 2 Ports For Withdrawal One For Iv Set & 1 For Needle Withdrawal) , Electrochemical Solution Releasing Active Chlorine Released 100 Ppm Active - Hocl (0.003%) Inactive - Naocl + Nacl (­0.1%) Purified Water - 99.9% With Neutral Ph, Non-Toxic, Human Skin Friendly For Wound Care Cleansing & Irrigation - 1000 Ml Irrigation Bag With Closed System (Self Collapsible & 2 Ports For Withdrawal One For Iv Set & 1 For Needle Withdrawal) , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Soresfor Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85% -15 Gm Gel Tube , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Sores For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85% -30 Gm Gel Tube , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Sores For Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85%-50 Gm Gel Tube , Wound Care Gel Tube For Moistening And Debridement Of Acute And Chronic Wounds Such As Stage I-Iv Ulcers, Venous Stasis And Diabetic Ulcerations, Post-Surgery Wounds And Bed Soresfor Bactericidal, Fungicidal Action As Gel, Ce Certified & Fda Approved Containing: Naocl (Sodium Hypochlorite) - 0.05%, Lithium Magnesium Sodium Silicate-(4%) And Sodium Chloride And Purified Water 95.85%-100 Gm Gel Tube , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. Size:7.5X7.5 Cm , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. Size:10X10 Cm , Highly Absorbent Polyurethane Foam Dressing With Soft And Gentle Skin Friendly Silicone Adhesive For Moderate To Highly Exuding Wounds, Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Superior Absorption, Waterproof And Bacteria Proof Semi-Permeable Polyurethane Top Film. Size:12.5X12.5 Cm , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:7.5X7.5 Cm , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:10X10 Cm , Soft And Gentle Silicone Adhesive With Antimicrobial Properties, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteria Proof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size: 12.5X12.5 Cm , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility.Size:5X5 Cm , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility.Size:7.5X7.5 Cm , Thin, Ultra Flexible And Absorbent Polyurethane Foam Dressing With A Semi-Permeable, Bacteria- And Waterproof Top Film And A Soft Silicone Adhesive Layer. Unique 3D Foam Structure Absorbs The Exudate Vertically And Locks The Fluid Away Within Its Structure,Leaving The Wound Moist For Optimal Wound Healing Conditions. The Soft And Thin Foam Pad At Skin Level Makes It Comfortable To Wear And Is Suited For Users That Need Increased Mobility.Size:12.5X12.5Cm , Non Adhesive Antimicrobial, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteriaproof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:10X20cm , Non Adhesive Antimicrobial, Highly Absorbent Foam Dressing With Polyurethane Top Layer Which Is Waterproof And Bacteriaproof Semi-Permeable. Profile Of Ionic Silver Upto 7 Days. Unique 3D Fit Foam Structure (Conforms To The Wound Bed, Absorbs Vertically, Retains Exudate) For Managing High To Moderate Exuding Infected Chronic Wounds. Size:20X20cm , Calcium Alginate Dressing With 65-75 % Guluronic Acid, Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption. For Managing Sloughy Wounds With Cavity.Size:3X44cm Ribbon Cavity , Calcium Alginate Dressing With A Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption And Gel Formation. 5.7%- 6.3% Sodium Zirconium Crystals Contains Silver Which Provide Broad And Continuous Antibacterial Profile For Upto 7 Days And Prevents Microbial Colonisation. For Managing Infected Sloughy Wounds With Cavity And Various Shapes, Sizes And Depths. Comes With Spin Finish To Prevent Fibre Shredding And Has Document Haemostatic Effect.Size:10X10 Cm , Calcium Alginate Dressing With A Unique Structure Of Calcium Alginate And Cmc Molecules Intertwined In Strings Resulting In Local Vertical Absorption And Gel Formation. 5.7%- 6.3% Sodium Zirconium Crystals Contains Silver Which Provide Broad And Continuous Antibacterial Profile For Upto 7 Days And Prevents Microbial Colonisation. For Managing Infected Sloughy Wounds With Cavity And Various Shapes, Sizes And Depths. Comes With Spin Finish To Prevent Fibre Shredding And Has Document Haemostatic Effect.Size:15X15cm , Hydrogel Consisting Of Natural Ingredients Such As Highly Purified Water, Sodium Carboxy-Methylcellulose And Calcium Alginate Without Any Additives. For Effective And Gentle Autolytic Debridement Of Necrotic Tissue, Dry And Sloughy Necrotic Wounds-15 Gm , Non-Invasive Skin Closure Strips With Sterile, Breathable, Non-Woven Rayon Backed Microporous Material Reinforced With Filaments For High Tensile Strength. Contains Hypoallergenic Adhesive To Reduce Skin Trauma. Dimension:12Mm X 100Mm (1/2 X 4 In)(Pack Of 50 Pcs) , Non-Invasive Skin Closure Strips With Sterile, Breathable, Non-Woven Rayon Backed Microporous Material Reinforced With Filaments For High Tensile Strength. Contains Hypoallergenic Adhesive To Reduce Skin Trauma. Dimension:6Mm X 100Mm (1/4 X 4 In) (Pack Of 50 Pcs) , Non-Invasive Skin Closure Strips With Sterile, Breathable, Non-Woven Rayon Backed Microporous Material Reinforced With Filaments For High Tensile Strength. Contains Hypoallergenic Adhesive To Reduce Skin Trauma. Dimension: 25Mm X 125Mm (1 X 5 In)(Pack Of 50 Pcs) , Sterile, Semipermeable, Transparent, Breathable, Water Proof, Bacterial And Viral Barrier Polyurethane Film (That Reduces Chance Of Infection) With Absorbent, Non-Adherent Pad (That Helps Reduce Trauma On Dressing Removal) And Latex Free Hypoallergenic Acrylic Adhesive That Is Gentle To Skin- Size: 9Cm X 10Cm (Pack Of 25 Pcs) , Sterile, Semipermeable, Transparent, Breathable, Water Proof, Bacterial And Viral Barrier Polyurethane Film (That Reduces Chance Of Infection) With Absorbent, Non-Adherent Pad (That Helps Reduce Trauma On Dressing Removal) And Latex Free Hypoallergenic Acrylic Adhesive That Is Gentle To Skin- Size:6Cm X 10Cm(Pack Of 50 Pcs) , Transparent, Semipermeable, Breathable, Water Proof, Bacterial And Viral Barrier, Synthetic Blood Penetration Resistance, Sterile, Polyurethane Film Peripheral Iv Dressing For Adults Reinforced With Soft Cloth Border And Notch. Non-Latex, Hypoallergenic Pattern Coated Acrylic Adhesive With 2 Large Extra Sterile Soft Cloth Tape Strips For Additional Securement And Complies With Iso-10993 Standards For Biocompatibility- Size: 6.5Cm X 7Cm (Pack Of 100 Pcs) , Silicone Gel Sheets For Scar Management - Size: 5 X5 Cm , Silicone Gel Sheets For Scar Management - Size: 10X10 Cm , Silicone Gel Sheets For Scar Management - Size: 20X20 Cm , Sterile Collagen Particles - 2.5Ml , Sterile Collagen Particles - 5Ml , Sterile Collagen Particles - 10Ml , Sterile Collagen Particles - 15Ml , Sterile Medicated Collagen Particles - 5Ml , Sterile Medicated Collagen Particles - 10 Ml , Sterile Medicated Collagen Particles - 15 Ml , Sterile Medicated Collagen Sheets In Dry Form Size: 10X10 Cm , Sterile Medicated Collagen Sheets In Dry Form Size: 10X20 Cm , Sterile Medicated Collagen Sheets In Dry Form Size: 15X30 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Wet Form - Size: 10X20 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Wet Form - Size: 15X30 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Dry Form - Size: 10X20cm , Collagen Sheets Pure Type 1&3 Triple Helical In Dry Form - Size: 15X30 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Meshed Form - Size: 10X20 Cm , Collagen Sheets Pure Type 1&3 Triple Helical In Meshed Form - Size: 15X30 Cm , Sterile Nano Oligosacchride Factor (Nosf) Foam Dressing With Border. Also Impreganted With Carboxy Methly Cellulose And Lipid Particles, Border - Size: 10 Cm X 10 Cm , Sterile Nano Oligosacchride Factor Foam (Nosf) Dressing With Border. Also Impreganted With Carboxy Methly Cellulose And Lipid Particles, Border- Size: 15 Cm X 20 Cm , Sterile Nano Oligosacchride Factor (Nosf) Contract Layer Dressing Impreganated Carboxy Methly Cellulose And Lipid Particles, Contact Layer - Size: 10 Cm X 10 Cm , Sterile Nano Oligosacchride Factor (Nosf) Contract Layer Dressing Impreganated Carboxy Methly Cellulose And Lipid Particles, Contact Layer - Size: 15 Cm X 20 Cm , Sterile Nano Oligosacchride Factor (Nosf) Micro Adhesive Dressingimpreganated Carboxy Methly Cellulose And Lipid Particles, Ma - Size: 10 Cm X 10 Cm , Sterile Nano Oligosacchride Factor (Nosf) Micro Adhesive Dressingimpreganated Carboxy Methly Cellulose And Lipid Particles, Ma - Size: 6 Cm X 6 Cm , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Micro Adhesive. Size 15Cmx 20Cm, European Ce Approved , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Micro Adhesive. Size 10Cmx 10Cm, European Ce Approved , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Micro Adhesive. Size 6Cmx 6Cm, European Ce Approved , Sterile Nano Oligosacchride Sucrose Factor ( Nosf) Healing Matrix, Contact Layer. Size 15 Cmx 20 Cm, European Ce Approved , Hyperoxygenated Glycerides Of Essestial Fatty Acid (Linoleic Acid 60%) With Tecopherol - 99% And Aniseed Pergume 1%, For Pressure Ulcer Prevention-Size 50 Ml , Hyperoxygenated Glycerides Of Essestial Fatty Acid (Linoleic Acid 60%) With Tecopherol - 99% And Aniseed Pergume 1%, For Pressure Ulcer Prevention-Size 20 Ml , Sterile Fish Collagen Type I Collagen Sponge -Size 10 X 10Cm , Occulusive Wound Dressing Non-Resorbable Which Contains Bio Cellulose 100%, Monolaurin 7%In A Sterile Pack-Size: 5 X 5 Cm , Occulusive Wound Dressing Non-Resorbable Which Contains Bio Cellulose 100%, Monolaurin 7%In A Sterile Pack-Size: 10 X 10 Cm , 2 Layer Polyurethane Ester Foam Dressings Size (11 X 8 X 1.8Cm) With Spiral Cut Sheet Use For Instillation (Not Irrigation), 1 Vac Instillation Trac Pad With 5 Lumen Tubing Set, 2 Sheets Of Vac Advanced Drape, 2 Packets Ofcavilon No Sting Barrier Film, 1 Disposable Ruler. With Cdsco And Fda & Ce Certified , 2 Layer Polyurethane Ester Foam Dressings Size (17 X 15 X 1.8Cm) With Spiral Cut Sheet Use For Instillation (Not Irrigation), 1 Vac Instillation Trac Pad Wit 5 Lumen Tubing Set, 2 Sheets Of Vac Advanced Drape, 2 Packets Ofcavilon No Sting Barrier Film,1 Disposable Ruler. With Cdsco And Fda & Ce Certified. , 2 Layer Polyurethane Ester Foam Dressings Size (25 X 15 X 1.6Cm) With Spiral Cut Sheet Use For Instillation (Not Irrigation), 1 Vac Instillation Trac Dual Pad With 5 Lumen Tubing Set, 5 Sheets Of Vac Advanced Drape, 4 Packets Ofcavilon No Sting Barrier Film,1 Disposable Ruler. With Cdsco And Fda & Ce Certified. , 3 Layer Foam Dressing Used For Instillation Therapy Size (25.6 X 15 X 0.8Cm, 25.6 X 15 X 1.6Cm, Contact Layer 25.6 X 15 X 0.8Cm W And 1Cm Circular Holes), 1 Vac Instillation Trac Pad With 5 Lumen Tubing Set, 4 Sheets Ofv.A.C. Advanced Drape, 4 Packets Ofcavilon No Sting Barrier Film,1 Disposable Ruler.With Cdsco And Fda & Ce Certified , 3 Layer Foam Dressings Used For Instillation Theraphy Size (25.6 X 15 X 0.8Cm, 25.6 X 15 X 1.6Cm, Contact Layer 25.6 X 15 X 0.8Cm And 1Cm Circular Holes), 1 Vac Instillation Trac Dual Pad With 5 Lumen Tubing Set, 6 Sheets Of Vac Advanced Drape,5 Packets Of Cavilon No Sting Barrier Film, 1 Disposable Ruler. With With Cdsco And Fda & Ce Certified , 500 Ml Canister (Sterile) Sensing Tracing Pad With 5 Lumen Tubing Set Prevent Leakage And Blockage, With Gel (Containing Sodium Polyacrylate To Covert Exudate Into Gel, So No Cross Contamination) And Clamp And Connector. With Cdsco And Fda & Ce Certified , 300 Ml Canister (Sterile) Sensing Trac Pad With 5 Lumen Tubing Prevent Leakage And Blockage, With Gel (Containing Sodium Polyacrylate To Covert Exudate Into Gel, So No Cross Contamination) Andclamp And Connector. With Cdsco And Fda & Ce Certified , 1000 Ml Canister (Sterile) With Instillation Trac Pad With 5 Lumen Tubing Set For Prevent Leakage And Blockage With Gel (Containing Sodium Polyacrylate To Covert Exudate Into Gel, So No Cross Contamination) And , Clamp And Connector. With Cdsco And Fda & Ce Certified , Foam Dressing (10 X 7.5 X 3.2Cm), 2 Sheets Of Vac Drape, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 300 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connector With Cdsco And Fda & Ce Certified , Foam Dressing (18 X 12.5 X 3.2Cm), 2 Sheets Of Vac Drape, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 500 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connectorwith Cdsco And Fda & Ce Certified , Foam Dressing (26 X 15 X 3.2Cm), 2 Sheets Of Vac Drape, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 1000 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connector With Cdsco And Fda & Ce Certified , Foam Dressing (26 X 15 X 1.6Cm), 2 Sheets Of Vac Drape, 1 Instillation Trac Pad With 5 Lumen Tubing Set With Connector, 1 Disposable Ruler, 5 Lumen Trac Padtechonology With Connector, 1 Disposable Ruler, 1 Canister 300 Ml (Sterile) With 5 Lumentechonologytubing, Clamp And Connector With Cdsco And Fda & Ce Certified , Cassette With Instillation Tubing And 38Mm Spikeable Cap Adaptor. With Cdsco And Fda & Ce Certified , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm - Size: 5 X 5 Cm , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm - Size: 10 X 10 Cm , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm Size Dressing Impregnanted With Silver Ions And Sustained Release Upto 7 Days, Silver Content Of 1.5 Mg/Cm2 - Size: 5 X 5 Cm , An Absorbent, Non Adherent Sterile Dressing With More Than 98% Silk Proteins. Nvtr Rate More Than 900 Kg/M2/24 Hours, Thickness Of Less Than 2Mm Size Dressing Impregnanted With Silver Ions And Sustained Release Upto 7 Days, Silver Content Of 1.5 Mg/Cm2 - Size: 10 X 10 Cm , Anti Biofilm Wound Irrigation Solution With Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 40 Ml , Anti Biofilm Wound Irrigation Solution With Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 350 Ml , Anti Biofilm Wound Irrigation Rinsing Solution With Betaine Surfactant And 01% Polyaminopropyl Biguanide (Polithexanide) 1000 Ml , Anti Biofilm Wound Gel With Glycerol, Hydroxyethylcellulose, Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 30 Mg , Anti Biofilm Wound Gel With Glycerol, Hydroxyethylcellulose, Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 50 Gms , Anti Biofilm Wound Gel With Hydroxyethylcellulose, Glycerol, Betaine Surfactant And 0.1% Polyaminopropyl Biguanide (Polithexanide) 250 Gms , Lipido-Colloid Wound Contact Layer Impregnated With Silver Salts And Poly-Absorbent Fibres - Size: 6X6 Cm , Lipido-Colloid Wound Contact Layer Impregnated With Silver Salts And Poly-Absorbent Fibres - Size: 10X10 Cm , Lipido-Colloid Wound Contact Layer Impregnated With Silver Salts And Poly-Absorbent Fibres - Size: 15X20 Cm , Sterilenon-Occlusivewound Contact Layer Composed Of A Polyester Mesh Impregnatedwithhydrocolloid Particles (Cmc), Cohesion Polymers And Petroleum Jelly Usinglipido-Colloid Technology (Tlc) - Size: 10 X 10Cm , Sterilenon-Occlusivewound Contact Layer Composed Of A Polyester Mesh Impregnatedwithhydrocolloid Particles (Cmc), Cohesion Polymers And Petroleum Jelly Usinglipido-Colloid Technology (Tlc) - Size: 15 X 20 Cm , Sterilenon-Occlusivewound Contact Layer Composed Of A Polyester Mesh Impregnatedwithhydrocolloid Particles (Cmc), Cohesion Polymers And Petroleum Jelly Usinglipido-Colloid Technology (Tlc) - Size: 20 X 30 Cm , Sterilenon-Occlusive Woundcontact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles (Cmc), Petroleum Jelly, Polymers And Silver Salts (Ag) Usinglipido- Colloid Technology (Tlc) - Size: 10 X 10 Cm , Sterilenon-Occlusive Woundcontact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles (Cmc), Petroleum Jelly, Polymers And Silver Salts (Ag) Usinglipido-Colloid Technology (Tlc) - Size: 15 X 20 Cm , Sterile Non-Occulusive Wound Contact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles (Cmc), Petroleum Jelly, Polymers And Silver Salts (Ag) Usinglipido-Colloid Technology (Tlc) - Size: 20 X 30 Cm , Sterile Wound Contact Layer Consists Of Silver Salts, Poly-Absorbent Fibres, Hydrocolloid Particles (Cmc), Petroleum Jelly And Polymers Usinglipido-Colloid Technology (Tlc) - Size: 6 Cm X 10Cm , Sterile Wound Contact Layer Consists Of Silver Salts, Poly-Absorbent Fibres, Hydrocolloid Particles (Cmc), Petroleum Jelly And Polymers Usinglipido-Colloid Technology (Tlc) - Size: 10 Cm X 10 Cm , Sterile Wound Contact Layer Consists Of Silver Salts, Poly-Absorbent Fibres, Hydrocolloid Particles (Cmc), Petroleum Jelly And Polymers Usinglipido-Colloid Technology (Tlc) - Size: 15 Cm X 20 Cm , Sterile Self -Adherent Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad, A Super Absorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing - Size: 8 X 8 Cm , Sterile Self -Adherenttlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad, A Super Absorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing - Size: 13 X 13 Cm , Sterile Self -Adherenttlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad, A Super Absorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing - Size: 10 X 25 Cm , Sterile Non-Woven Pad Composed Of Cohesive And Highly Absorbent Hydro-Desloughing Fibres (Polyacrylate), Combined Withtlc Matrix (Lipido Colloid Technology) Wound Contact Layer To Absorb, Trap And Drainage Of Slough From The Wounds. Sizes: 6X6 Cm , Sterile Non-Woven Pad Composed Of Cohesive And Highly Absorbent Hydro-Desloughing Fibres (Polyacrylate), Combined With Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer To Absorb, Trap And Drainage Of Slough From The Wounds. Sizes: 10X10 Cm , Sterile Non-Woven Pad Composed Of Cohesive And Highly Absorbent Hydro-Desloughing Fibres (Polyacrylate), Combined With Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer To Absorb, Trap And Drainage Of Slough From The Wounds. Sizes: 15X20 Cm , Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver With Edta & Bec, Ce, Iso & Fda Approved - Size:5 X 5Cm , Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver With Edta & Bec, Ce, Iso & Fda Approved - Size: 10 X 10 Cm , Hydrophilic Foam Dressing - Size: 10X10cm , Hydrophilic Foam Dressing - Size: 15X30cm , Hydrophilic Foam Silver Pad Dressing (Non-Adhesive And Antimicrobial) - Size:10X10cm , Hydrophilic Foam Silver Pad Dressing (Non-Adhesive And Antimicrobial) - Size: 15X30cm , Hydrocolloid Dressing With Absorbable Foam Padding (Extra-Thin Dressing) - Size: 10X10cm , Hydrocolloid Dressing With Absorbable Foam Padding- Size: 15X30 Cm , Sterile Human Amnion Chorion And Phmb Powder (3G ) , Sterile Polyhexamethylene Biguanide Coated Dehydrated Human Amnion Chorion Allograft - Size: 5X5 Cm , Sterile Polyhexamethylene Biguanide Coated Dehydrated Human Amnion Chorion Allograft - Size: 8X6 Cm , Sterile Polyhexamethylene Biguanide Coated Dehydrated Human Amnion Chorion Allograft- Size: 12X6 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 6X7 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 8X10 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 10X15 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 10X25 Cm , Film Dressing With Anti-Microbial Pad Using Dtac Technology-Size: 10X35 Cm , Topical Skin Adhesive For Wound Closure - 2-Octyl Cyanoacrylate High Viscosity Formulation For Small Incisions And Lacerations; 0.36 Ml Adhesive Volume , Semipermeable Waterproof Plastic Wound Dressing With Silver - Size: 5 Cm X 7 Cm , Semipermeable Waterproof Plastic Wound Dressing With Silver - Size: 15 Cm X 15 Cm , Semipermeable Adhesive Dressing Clear 6 X 7 Cm , Semipermeable Adhesive Dressingclear 8.5 X 10.5 Cm , Transparent Film Dressings Of A Thin Film Backing With Hypoallergenic, Latex-Free Adhesive - Size 6 Cm X 7 Cm , Transparentsemi Permeable Dressing Frame Style For Neonates Without Pad 10 Cm X 12 Cm Made Of Hypoallergenic, Latex-Free Adhesive , Transparentsemi Permeable Dressing Frame Style For Neonates Without Pad 6 Cm X 7 Cm Made Of Hypoallergenic, Latex-Free Adhesive , Adhesive Bandage Strips For Skin Closure Size 0.25X1.5 (Cost Per Strip Will Be Taken For Comparison Of Price) , Adhesive Bandage Strips For Skin Closure Size 0.25X4 (Cost Per Strip Will Be Taken For Comparison Of Price) , Adhesive Bandage Strips For Skin Closure Size 0.5X2 (Cost Per Strip Will Be Taken For Comparison Of Price) , Adhesive Bandage Strips For Skin Closure Size 0.5X4 (Cost Per Strip Will Be Taken For Comparison Of Price) , Reinforced Adhesive Skin Closures 0.125X3 (Cost Per Strip Will Be Taken For Comparison Of Price) , Reinforced Adhesive Skin Closures 1X5 (Cost Per Strip Will Be Taken For Comparison Of Price) , Silver Dressing With Pu Backing Layer And Absorbant Pad Dressing - Size: Dressing 5 X 7 Cm And Pad 2.5 X 4 Cm , Silver Dressing With Pu Backing Layer And Absorbant Pad Dressing - Size: Dressing 15 X 15 Cm And Pad 10 X 10Cm , Silver Dressing With Pu Backing Layer And Absorbant Pad Dressing - Size: Dressing 9 X 35Cm And Pad 5 X 30Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer - Size: 10 Cm X 10 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer - Size: 10 Cm X 20 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer - Size: 15 Cm X 15 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer (Sacrum) - Size: 17.5 Cm X 17.5 Cm , Super - Absorbant, Polyurethane Foam Dressing With Vertical Absorption With Silicone Wound Contact Layer Heel 2D - Size: 16 Cm X 24 Cm , Super - Absorbant, Bacteria Binding Polyurethane Foam Dressing With Dialkyl Carbamoyl Chloride Layered - Size: 12.5 Cm X 12.5 Cm , Super - Absorbant, Bacteria Binding Polyurethane Foam Dressing With Dialkyl Carbamoyl Chloride Layered- Size: 15 Cm X 15 Cm , Super - Absorbant, Bacteria Binding Polyurethane Foam Dressing With Dialkyl Carbamoyl Chloride Layered - Size:17.5 Cm X 17.5 Cm , Antimicrobial Hydrocellular Foam Dressing. Ag Non Adhesive - Size: 10 Cm X 10 Cm , Antimicrobial Hydrocellular Foam Dressing. Ag Non Adhesive - Size: 12.5 Cm X 12.5 Cm , Antimicrobial Hydrocellular Foam Dressing. Ag Non Adhesive - Size: 15 Cm X 15 Cm , Antimicrobial Silver Dressing With Nano Crystallinewith Sustained Release Of Silver For 7 Days Having Polyster Mesh Size 15 Cm X 15 Cm , Antimicrobial Silver Dressing With Nano Crystallinewith Sustained Release Of Silver For 7 Days Having Polyster Mesh Size 10 Cm X 12.5 Cm , Hydrocellular Foam Dressing With Silicone Adhesive - Size: 10 Cm X 10 Cm , Hydrocellular Foam Dressing With Silicone Adhesive - Size: 10 Cm X 20 Cm , Hydrocellular Foam Sacrumdressing With Silicone Adhesive - Size: 16.8 Cm X 17.1 Cm , Self Adhesive Silicone Gel Sheet - Size: 12 Cm X 6 Cm , Super Oxidized Solution With Hypochlorous Acid 0.003% And Sodium Hypochlorite 0.004% With Neutral Ph - 100Ml , Super Oxidised Solution - Irrigation Solution With Hypochlorous Acid In Oxidized Water Base- 60Ml , Super Oxidized Gel With Hypochlorous Acid 0.008% And Sodium Hypochlorite 0.002%With Neutral Ph - 60Gm , Microbial Antiseptic Solution Poly Hexamethylene Biguanide - 100Ml , Hyaluronicacid Sodium Salt Gel - 50Gm , Phmb Impregnated Antimicrobial Dressing - Size 10X10 Cm And Absorbent Pad 5 X 5 Cm , Phmb Impregnated Antimicrobial Dressing - Size 10X25 Cm And Absorbent Pad 5 X 20 Cm , Antimicrobial Nano Crystaline Silver Dressing. Rayon Polyster Mesh Sandwiched Between Polyethylene Layers Binded With Ultrasonic Welds. Size 10Cm X 10 Cm , Antimicrobial Nano Crystaline Silver Dressing. Rayon Polyster Mesh Sandwiched Between Polyethylene Layers Binded With Ultrasonic Welds. Size 15Cm X 15 Cm , Antimicrobial Nano Crystaline Silver Dressing. Sustained Release Of Silver 70-100 Ppm For 3 Days Should Allow Fewer Dressing Changes. Size 20 Cm X 20 Cm , Antimicrobial Nano Crystaline Silver Dressing. Sustained Release Of Silver 70-100 Ppm For 3 Days Should Allow Fewer Dressing Changes. Size 15 Cm X 15 Cm , Tulle Gras Paraffin Gauze Dressing Medicated 10 Cm X 10 Cm , Tulle Gras Paraffin Gauze Dressing Chlorhexidine Medicated 15 Cm X 30 Cm , Partially-Hydratedamorphous Hydrogel15gms , Amorphous Hydrogel Wound Dressing Antimicrobial Antibacterial Gel With Nano Silver - 15 Gms , Amorphous Hydrogel Wound Dressing Antimicrobial Antibacterialgel With Nano Silver - 50 Gms , Cmc Sodium Wound Dressing Gel-15 Gms , Transparent Polyurethane Surgical Drape Size 40 Cm X 42 Cm , Transparent Polyurethane Surgical Drape Size 30 Cm X 28 Cm , Waterproof & Bacteria Proof Post-Operative Film Dressing For Post Surgical Wounds & Minor Trauma Wounds Size 9.5 Cm X 8.5 Cm , Waterproof & Bacteria Proof Post-Operative Film Dressing For Post Surgical Wounds & Minor Trauma Wounds Size 15.5 Cm X 8.5 Cm , Transparent Film Roll. Thin Waterproof Polyurethane Film With High Mvtr With Low Allergy Water Based Acrylic Adhesive That Minimizes The Risk Of Skin Irritation Or Sensitivity, Film Is Highly Conformable And Extensible To Fit To Awkward Dressing Areas, Unique And Novel Roll Format Enables Rapid And Economical Use- Size:10 Cm X 10 Cm , Stainless Steel Suture 5-0/ 6-0 (Pack Of 12 Nos) , Synthetic Absorbable Sutures (Polyglycolic Acid/Polyglactin 910) -4/0 With 16Mm 5/8 Circle Cutting 45Cm (Pack Of 12 Foils) , Absorbent, Low Adherent Post Operative Dressing With Adhesive Coated Backing Material. - Size: 15 Cm X 8 Cm , Absorbent, Low Adherent Post Operative Dressing With Adhesive Coated Backing Material. - Size: 25 Cm X 10 Cm , Negative Pressure Wound Therapy Dressing. Subatmospheric Pressure Therapy Pu Foam - Size: 10X 10 X 2.8 Cm And 0.4Ltr Fluid Cask With Gel , Negative Pressure Wound Therapy Dressing. Subatmospheric Pressure Therapy Pu Foam - Size: 10X 15 X 2.8 Cm And 0.4Ltr Fluid Cask With Gel , Negative Pressure Wound Therapy Dressing. Subatmospheric Pressure Therapy Pu Foam - Size: 23.8 X 15.8X 2.8 Cm And 1 Ltr Fluid Cask With Gel , Dressing Material For Negative Pressure Wound Therapy Dressing Kit Consister - 500Ml Capacity Large , Dressing Material For Negative Pressure Wound Therapy Dressing Kit Consister - 500Ml Capacity Medium , Dressing Material For Negative Pressure Wound Therapy Dressing Kit Consister - 500Ml Capacity Small , Vinyl Acetate Copolymer 250Ml/1000Mldisposable Exudate Collectionpouch Individually Sealed In Sterile Package, Used With 250Ml / 1000Ml Reusable Containers. The Securely Mounted Pouch Tube Consists Of 3 Active Ventilation Lumens And 1 Exdate Lumen. It Should Have Chemical Filter To Trap Moisture, Odour, To Monitor The Amount Of Infections Fluid Being Removed, To Solidify Infectious Fluid And Should Have Minimum Capacity , Advance Wound Care Dressing, Non-Woven Highly Absorbent, Hemostatic Gelling Fiber Composed Of 100% Natural Biopolymer With A Net Positive Charge, Gamma Sterilized And Moisture Proof Packing, Manufactured In India, Gmp And Iso 13485 Certified. Size: 10X10 Cm , Advance Wound Care Dressing, Non-Woven Highly Absorbent, Hemostatic Gelling Fiber Composed Of 100% Natural Biopolymer With A Net Positive Charge, Gamma Sterilized And Moisture Proof Packing, Manufactured In India, Gmp And Iso 13485 Certified. Size: 15 X 15 Cm , Microsutures Polymide Black Coloured 11/0 Needle Thickness 70-100 Microns Length 3.5 - 5Mm3.8 Circle135 Degreesmicro Taper Point(Pack Of 12 Nos) , Microsutures Polymide Black Coloured10/0 Needle Thickness 70- 100 Microns Length 3.5 - 5Mm3.8 Circle 135 Degrees Micro Taper Point (Pack Of 12 Nos) , Microsutures Polymide Black Coloured9/0 Needle Thickness 100-150 Microns Length 3.5 - 5Mm3.8 Circle 135 Degrees Micro Taper Point (Pack Of 12 Nos) , Microsutures Polymide Black Coloured8/0 Needle Thickness 100-150 Microns Length4 - 7 Mm3.8 Circle 135 Degrees Micro Taper Point (Pack Of 12 Nos) , Hydrophilic Non-Woven Gauze Roll, Impregnated With A Naturally Occurring Inorganic Mineral - Kaolin, Along With A Unique Direct Pressure Adhesive Bandage Packaged In A Foil Pouch For Aseptic Removal - 7.6 Cm X 3.7 Cm , Hemostatic Dressing For External Application, 4 Ply Non-Woven Gauze - Size:4 X 4 Inches, Impregnated With A Naturally Occurring Inorganic Mineral - Kaolin, With A X-Ray Detectable Strip Packaged In A Foil Pouch For Aseptic Removal.Fda & Ce Approved , Patient Pre-Operative Skin Preparation Solution 25 Ml In One-Step Sterile Applicator Container For Single Use With 2% Chg And 70% Ipa With Orange Tint Color For Visibility. Fda Approved. , Patient Pre-Operative Skin Preparation Solution 10 Ml In 0Ne-Step Sterile Applicator Container For Single Use With 2% Chg And 70% Ipa With Orange Tint Color For Visibility. Fda Approved. , Thromboembolism Stocking , Acellular Dermal Matrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (74X52x1mm), Usfda And Dcgi Approved , Acellular Dermal Matrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (74X52x2mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (148X105x1mm) Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (52X37x1mm) , Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, Conformable At Complicated Anatomic Areas, Easy To Use, Handle And Apply. Size (52X37x2mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (74X52x1mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Flexible, More Collagen, Stronger, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (148X105x2mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (74X52x3mm), Usfda And Dcgi Approved , Acellular Dermal Matrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (52X37x1mm) , Usfda And Dcgi Approved , Acellular Dermalmatrix, Fenestrated, Non- Chemical Cross Linked, For High Exudating Wounds, Easy To Use, Handle And Apply. Size (52X37x3mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Single Step Procedure For Dermal Regeneration, Non- Chemical Cross Linked, Room Tempreture Storage, Size(74X52x1mm), Usfda And Dcgi Approved , Acellular Dermalmatrix, Single Step Procedure For Dermal Regeneration, Non- Chemical Cross Linked, Room Tempreture Storage, Size(52X37x1mm), Usfda And Dcgi Approved , Dermal Regeneration Template Bilayer (Bovine Collagen And Glycosaminoglycan (Chondroitin-6- Sulfate) And Silicone Layer - Size: 2In X 2In (5Cmx5cm) , Dermal Regeneration Template Bilayer (Bovine Collagen And Glycosaminoglycan (Chondroitin-6- Sulfate) And Silicone Layer - Size: 4In X 5In (10Cmx12.5Cm) , Dermal Regeneration Template Bilayer (Bovine Collagen And Glycosaminoglycan (Chondroitin-6- Sulfate) And Silicone Layer - Size: 4In X 10In (10Cmx25cm) , Meshed Dermal Regeneration Template Bilayer - Mesh (Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer - Size: 2In X 2In (5Cmx5cm) , Meshed Dermal Regeneration Template Bilayer - Mesh (Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer - Size: 4In X 5In (10Cmx12.5Cm) , Meshed Dermal Regeneration Template Bilayer - Mesh (Bovine Collagen And Glycosaminoglycan (Chondroitin-6-Sulfate) And Silicone Layer - Size: 4In X 10In (10Cmx25cm) , 2 Octyl Cyanoacrylate Adhesive In A Special Aluminium Collapsible Tube Pack ( 2 X 1.75Gm) And Applicator Having Self Puncturing Cap And A Soft Elastomeric Tip (Soft Bristles) For Ease Of Application Along With Curved Mesh Design Of Length 30 Cm Skin Closure System , 2 Octyl Cyanoacrylate Adhesive Having 1 Ml (One Ml)In A Special Aluminium Collapsible Tube Pack And Applicator Having Self Puncturing Cap And A Soft Elastomeric Tip , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Chronic & Acute Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rate Should Be 800 G/M2/24Hr Size - 10X10 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Chronic & Acute Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rate Should Be 800 G/M2/24Hr Size - 15X15 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Infected Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rateshould Be 800 G/M2/24Hr. 4) 7 Days Of Silver Releaseand Silver Content Of 1.5Mg/Cm2size - 5X5 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Infected Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rateshould Be 800 G/M2/24Hr. 4) 7 Days Of Silver Releaseand Silver Content Of 1.5Mg/Cm2 Size - 20X20 Cm , Silk Protein Based Sterile Surgical Wound Dressing Sheet For Infected Wounds. The Silkdressing Should Also Have Below Parameters : 1)Silk Content Should Be More Than 75% 2)Thickness Of Silk Should Be More Than 1.2 Mm 3)Moisturevapor Transmission Rateshould Be 800 G/M2/24Hr. 4) 7 Days Of Silver Releaseand Silver Content Of 1.5Mg/Cm2 Size - 30X30 Cm , Hydrophobic Bacteria And Fungi Binding Wound Dressing Pad,Consists Of A Dacc Coated Wound Contact Layer Combined With An Absorbent Core-Size: 10X10 Cm , Hydrophobic Bacteria And Fungi Binding Wound Dressing Pad,Consists Of A Dacc Coated Wound Contact Layer Combined With An Absorbent Core-Size: 10X20 Cm , Non-Absorbent Bacteria And Fungi Binding Wound Contact Layer,Consists Of A Dacc-Coated 8 Folded Wound Contact Layer. Size: 7X10 Cm , Bacteria And Fungi Binding Absorbent Polyurethane Foam With Super-Absorbent Stripes Which Absorb And Lock Additional Wound Exudate With Wound Contact Surface Consists Of A Dacccoated Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour. Size: 10X10 Cm , Bacteria And Fungi Binding Absorbent Polyurethane Foam With Super-Absorbent Stripes Which Absorb And Lock Additional Wound Exudate With Wound Contact Surface Consists Of Adacccoated Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour. Size: 12.5X12.5 Cm , Bacteria And Fungi Binding Absorbent Polyurethane Foam With Super-Absorbent Stripes Which Absorb And Lock Additional Wound Exudate With Wound Contact Surfaceconsists Of Adacccoated Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour. Size: 15X15 Cm , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 7Cmx9cm Oval , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer With A Silicon Fixation Border And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 12.5Cmx12.5Cm , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 10Cmx10cm , Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size.Size: 10Cmx20cm , Anatomically Heel Shaped Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size. Size: 16Cmx24cm , Anatomically Heel Shaped Silicone Coated Absorbent Polyurethane Foam Dressing That Contains Super-Absorbent Stripes Which Absorb And Lock Wound Exudate. With Perforated Silicone Wound Contact Layer And Water-Repellent Outer Film, Yet Permeable To Oxygen And Vapour And If Necessary The Dressing Can Be Cut To Size And With Two Fixation Strips Are Placed In The Peel Pouch Meant For Fixation Of The Dressing To The Heel. , Knee High Open Toe Gradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long - Extra Large , Knee High Open Toe Gradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long - Large , Knee High Open Toe Gradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long - Medium , Thigh High Open Toegradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long With An Silicon Impregrantedthigh Band- Extra Large , Thigh High Open Toegradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long With An Silicon Impregrantedthigh Band- Large , Thigh High Open Toegradient Compression Stockings With A Decreasing Pressure Gradient From Distal To Proximal With Effective Moisture Wicking Technology Contains 40% Elastane And 60% Polyamide Of Innovative Nilit Aquarius Fibers Wick Away Moisture And Give A Feeling Of Comfort All Day Long With An Silicon Impregrantedthigh Band- Medium , Compression System With Two Components, A Medical Stockingwith 76% Polyamide And A Compression Liner With 79% Polyamide And 5% Silk, Provide A Nominal Compression Of 40 Mmhg* At The Ankle With Decreasing Pressure Gradient From Distal To Proximal -Large , Compression System With Two Components, A Medical Stockingwith 76% Polyamide And A Compression Liner With 79% Polyamide And 5% Silk, Provide A Nominal Compression Of 40 Mmhg* At The Ankle With Decreasing Pressure Gradient From Distal To Proximal - Extra Large , Compression System With Two Components, A Medical Stockingwith 76% Polyamide And A Compression Liner With 79% Polyamide And 5% Silk, Provide A Nominal Compression Of 40 Mmhg* At The Ankle With Decreasing Pressure Gradient From Distal To Proximal - Medium , Leg Wrap Withshort Stretch Adjustable Compression Band System With 50% Overlapping Wraps Contains 82% Polyamide And 18% Elastane Along With Non-Compressive Linerscontains 96% Polyamide And 4% Elastane , Foot Wrap Withshort Stretch Adjustable Compression Band System With 50% Overlapping Wraps Contains 82% Polyamide And 18% Elastanealong With Non-Compressive Linerscontains 96% Polyamide And 4% Elastane , Knee Wrap Withshort Stretch Adjustable Compression Band System With 50% Overlapping Wraps Contains 82% Polyamide And 18% Elastane With Non-Compressive Linerscontains 96% Polyamide And 4% Elastane , Multipurpose Tube Holder For Foley Catheters , Polyurethane Foam Mattress 23 Density 72X36 Mm (In Rolls) , Microcuff Endotracheal Tube (Oral, Curved) Forpediatrics -Size 4 Mm , Laparotomy Drape , Craniotomy Drape , Surgeon Gown (Large Size) Which Is A Fully Wrap Around Variety And Can Be Tied In Front, With Water, Alcohol Resistance. Outer Layer Spun Bound Repellant Layer With Inner Two Layers With Antibacterial Property (Melt Blown), And Innermost Layer For Fabric Strength (Spun Bound) Soft Elastic Wrist Cuff. Adjustable Neck Line Needed. Low Linting. Sample Absolutely Required. Must Meet Or Exceed Enl3795 Standards Or Else Will Not Be Considered. Quote Separately For Tape Covered Double-Stitched Seam Type Gown As Well As The One With Ultrasound Bonded Seam , Endotracheal Tube With Polyurethane Cuff (Size: 5.0, 5.5, 6.0,6.5) (Pack Of 10) , Endotracheal Tube With Polyurethane Cuff (Size: 2.5, 4.5)(Pack Of 10) , Oxygen Mask Without Nebulizer - Adult , Oxygen Mask Without Nebulizer - Pediatrics , Dial Flow (I.V. Infusion Dial Regulator) Flow Rates From 20 To 250Ml / Hr; Stable Flow Rates Upto 72 Hrs; Reliable And Accurate Flow Control; Dial With Ridges For Easy Grippingand Adjustment , Nrbm Face Mask With Reservoir Bag - Adult , Bacterial Filter , Oral Airway , T-Piece Connector , Catheter Mount , Ventilator Circuit , Burette Set , Microscope Cover - Medium Compatible With Leica M525 Mc1 , Microscope Cover - Medium Compatible With Carl Zeiss , Glycolic Acid Peels For Scar Treatment 20% - 100Ml , Glycolic Acid Peels For Scar Treatment 35% - 100Ml , Glycolic Acid Peels For Scar Treatment 50% - 100Ml , Glycolic Acid Peels For Scar Treatment 75% - 100Ml , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Round 150 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes -Round 210 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Round 310 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Round 400Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 170 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 250 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 260 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 300 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Rectangular 350 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Elliptical 150Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Elliptical 250 Cc , Tissue Expanders With Injection Port And Stainless Steel Connector Of Various Sizes And Shapes - Elliptical 125 Cc , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 2H With Gap , Titaniumlow Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H With Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 6H With Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 6H Without Gap , Titanium Low Profile Plates (Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H- L Right , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 4H- L Left , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 1.5 X 5H- L Lt & Rt , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Orbital Plate Short Bar 0.6 Mm Thicknessscrew 1.5 Mm4/6 Holes , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 8 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 12 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 16 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.6 Mm 24 Holed Without Gap , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.8 Mm 10 Holes , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.8 Mm 12 Holes , Titanium Low Profile Plates(Plate Thickness 0.6 Mm Screw Diameter 1.5 Mm)For Craniofaciomaxillary Surgery - Mini Plate 0.8 Mm 16 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Short 1Mm 6 Holes Left , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Short 1Mm 6 Holes Right , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Long1mm6 Holes Right , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle Long 1Mm6 Holes Left , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle1mm Long5 Holes Right , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - L Plate Right Angle1mm Long5 Holes Left , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate4 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 6 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 8 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 12 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate16 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate 20 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate With Bar 2 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate With Bar 4 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Mini Plate With Bar 6 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Y Plate 1 Mm 4 Holes Short , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Y Plate 1 Mm 4 Holes Long , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - Double Y Platebroad 1 Mm6 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - T Plate 1 Mm 4 Holes , Titanium High Profile Plates(Plate Thickness 1.0 Mm Screw Diameter 2.0 Mm) - X Plate 1 Mm5 Holes , Titanium Reconstruction Plates (Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleright 16 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleleft 16 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleright 20 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleleft 20 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleright 24 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate With Angleleft 24 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate - Straight - 16 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate Straight - 20 Holes , Titanium Reconstruction Plates(Plate Thickness 2Mm, Screw Diameter 2Mm) - Reconstruction Plate - Straight - 24 Holes , Titanium Screws For Kls Martin System1.5 X 4Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 6Mm(To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 8Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 10Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System1.5 X 12Mm (To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System 2Mm X 4Mm(To Be Supplied With Screwdriver) , Titanium Screws For Kls Martin System 2Mm X 6Mm(To Be Supplied With Screwdriver) , Titanium Self Drilling Screws 1.5 Mm , Length 4 Mm (Pack Of 1 Unit) , Titanium Self Drilling Screws 1.5 Mm , Length 5 Mm (Pack Of 1 Unit) , Self Drilling Screws 1.5 Mm Length 8 , Self Drilling Screws 2 Mm Length 4 , Self Drilling Screws 2 Mm Length 6 , Self Drilling Screws 2 Mm Length 8 , Titanium Midfacial (Outer Diameter 1.5Mm) Self-Tapping Screw-6 Mm Length (Pack Size - 1 No) , Titanium Mandible (Outer Diameter 2Mm) Self-Tapping Screw-6 Mm Length (Pack Size - 1 No) , Titanium Mandible (Outer Diameter 2Mm) Self-Tapping Screw-8 Mm Length (Pack Size - 1 No) , Titanium Reconstruction (Outer Diameter 2.3/2.4Mm) Self-Tapping Screw-10 Mm Length (Pack Size - 1 No) , Titanium Reconstruction (Outer Diameter 2.3/2.4Mm) Self-Tapping Maxi Screw-12 Mm Length (Pack Size - 1 No) , Breast Implant Insertion Device- Funnel Constructed Of A Flexible, Transparent, Polymeric Filmthat Accommodates A Variety Of Gel Breast Implant Shapes And Sizes , External Mandibular Distractors Unidirectional , External Mandibular Distractors Bidirectional , Intraoral Mini Distractors For Mandible Right 10Mm(Titanium) , Intraoral Mini Distractors For Mandible Right 15Mm (Titanium) , Intraoral Mini Distractors For Mandible Right 20Mm (Titanium) , Intraoral Mini Distractors For Mandible Right 25Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 10Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 15Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 20Mm (Titanium) , Intraoral Mini Distractors For Mandible Left 25Mm (Titanium) , Intraoral Mini Distractors Vertical For Alveolar 2+2 Holes 3+3 Holes (Titanium) , Intraoral Mini Distractors For Maxilla Left (Titanium) , Intraoral Mini Distractors For Maxilla Right (Titanium) , Drill Bits 1.2/1.3 Mm Flute With Stop/Guard - Short , Drill Bits 1.2/1.3 Mm Flute With Stop/Guard - Long , Drill Bits 1.4/1.5 Mm Flute With Stop/Guard - Short , Drill Bits 1.4/1.5 Mm Flute With Stop/Guard - Long , Drill Bits 1.6 Mm Flute With Stop/Guard - Short , Drill Bits 1.6 Mm Flute With Stop/Guard - Long , Drill Bits 1.8 Mm Flute With Stop/Guard - Short , Drill Bits 1.8 Mm Flute With Stop/Guard - Long , Drill Bits 2.3 Mm Flute With Stop/Guard - Short , Drill Bits 2.3 Mm Flute With Stop/Guard - Long , Drill Bits 1.2/1.3 Mm Flute , Drill Bits 1.4/1.5 Mm Flute , Drill Bits 1.6 Mm Flute , Drill Bits 1.8 Mm Flute , Drill Bits 2.3 Mm Flute , Electric Dermatome Blades For Zimmer Dermatome , Acellular Dermal Matrix For Grafting/Implant Size: 2X2cm - Thick , Acellular Dermal Matrix For Grafting/Implant Size: 4X6cm - Thick , Acellular Dermal Matrix For Grafting/Implant Size: 8X16cm - Thick , Microscope Handle Drapes (180 X 330) , Sheathed Microtip Cautery Tips 4 Cm Straight (3/32”) Sleeve , Sheathed Microtip Cautery Tips 3 Cm Straight (3/32”) Sleeve , Bipolar Forceps Curved Type Bend 4 Tip 2 Mm For Bipolar Diathermy , Bipolar Forceps Straight 5 Tip 2Mm For Bipolar Diathermy , Bipolar Forceps Straighttip Bend 6Tip 2Mmfor Bipolar Diathermy , Bipolar Rf Cable For Bipolar Diathermy , Varispeed Battery Pack For Resorbable Implant System Strykar Delta System , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 14 Holes, 1.4 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 21 Holes, 1.4 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 2 X 21 Holes, 1.4 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 2 X 21 Holes, 0.5 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Straight Plate, 3 X 21 Holes, 0.5 Mm Thick , Plates & Meshes For Resorbable Implant System Strykar - Delta System, Ladder Plate, 2X 5 Holes , Plates & Meshes For Resorbable Implant System Strykar - Delta System Resorb Straight Plate 14 Holes , Plates & Meshes For Resorbable Implant System Strykar - Mesh 55 X 55 X 1.0 Mm , Plates & Meshes For Resorbable Implant System Strykar - Mesh 55 X 55 X 1.4 Mm , Plates & Meshes For Resorbable Implant System Strykar - Delta System Mesh- 55 X 55Mm , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- Delta System, 1.7 X 4Mm Screw, Pkg. 10 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- Delta System, 1.7 X 5Mm Screw, Pkg. 10 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 1.7 X 4 Mm, Pkg. 4 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 1.7 X 5 Mm, Pkg. 4 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 1.7 X 6 Mm, Pkg. 4 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.2 X 4 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.2 X 6 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 4 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 6 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 8 Mm, Pkg. 2 , Screws Sizesfor Resorbable Implant System Strykar Delta Implant- 2.6 X 10 Mm, Pkg. 2 , Plate Holders & Cuttersfor Resorbable Implant System Strykar - 1.7 Mm Bone Tap , Plate Holders & Cuttersfor Resorbable Implant System Strykar - 2.2 Mm Bone Tap , Self-Holding Screws Drivers/Driver Bitsfor Resorbable Implant System Strykardelta System - 1.7 Mm Screwdriver Blade, 80 Mm , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 1.7 Mm, 3 & 4 Mm, Dent , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 1.7 Mm, 5 & 6 Mm, Dent , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 2.2 Mm, 4 Mm, Dent , Taps (Ranging From 1.3 Mm To 4 Mm)For Resorbable Implant System Strykar Delta System - Self-Drilling Tap 2.2 Mm, 6 Mm, Dent , K- Wire 0.8 Mm Dia6 Length , K- Wire 1.2 Mm Dia6 Length , K- Wire 1.5 Mm Dia6 Length , K- Wire 1.6 Mm Dia6 Length , K- Wire 1.0 Mm Dia12 Length , K- Wire 1.2 Mm Dia12 Length , K- Wire 1.5 Mm Dia12 Length , Adsons Fine Toothed Forceps With 2Mm Fine Tip (Comfort Of Surgeon For Prolonged Handling Will Be Used As Selection Criteria) , Beaver Handles Round, Knurled, Stainless 10.0 Cm L X 0.50 Cm D , Beaver Handles Round, Knurled, Stainless 13.0 Cm L X 0.50 Cm D , Fine Toothed Forceps , Fine Tip Right Angled Forceps , Kilner Dott Mouth Gag With Three Blades (Set Of 2) - Pediatric Size , Mc Donalds Dissecting Forceps (For Lip) Fine - 1Mm , Skin Graft Blade For Humbys Knife , Ssg Handle (Humbys) , Skin Hook (Single) , Skin Hook - Fine (Single) , Scalpel Blade Remover , Thudiccum Nasal Speculum (All Sizes Each) , Zygoma Elevator , Langenbeck Retractor , Non-Stick Bipolar Cable , Non-Stick Bipolar Forceps Fine Tips - Small , Non-Stick Bipolar Forceps Fine Tips - Medium , Non-Stick Bipolar Forceps Fine Tips - Large , Non-Stick Bipolar Forceps Fine Tips - Angled , Proctoscope - Small , Proctoscope - Medium , Proctoscope - Large , Bayonet Forceps , Dissecting Forceps (Toothed)-12 Cm , Dissecting Forceps (Non-Toothed)-12 Cm , Mosquito Forceps - Straight - 12 Cm , Mosquito Forceps - Curved - 12 Cm , Iris Scissors - Straight -12 Cm , Iris Scissors - Curved -12 Cm , Acrylic -Heat Cure-Clear (Pack 450Gm Powder & 275Ml Liquid) , Acrylic -Heat Cure-Pink (Pack 450Gm Powder & 275Ml Liquid) , Acrylic -Self Cure-Clear (Pack 400Gm Powder & 400Ml Liquid) , Acrylic -Self Cure-Pink (Pack 400Gm Powder & 400Ml Liquid) , Alginate Impression Material (Dustless) Pack Of 750Gm , Carborundum Discs (For Mandrel Mount) - Pack Of 10 , Cold Mount Seal (Pack Of 450Ml) , Dappen Dish (Pack Size - 1 No.) , Dental Stone (Pack Of 3 Kg) , Die Stone (Pack Of 3 Kg) , Disc Mandrel (Pack Size - 1 No.) , Modelling Wax Sheet No.2 (Pack Of 10 Sheets) , Mouth Mirror With Handle (Pack Size - 1 No.) , Plaster Of Paris (Type Ii) (Pack Of 5 Kgs) , Polishing Buff For Dental Lathe (Pack Size - 1 No.) , Pumice Powder For Polishing Dentures (Pack Of 2 Kg) , Sandpaper Mandrel (Pack Size - 1 No.) , Soft Putty Impression Material (Pack Of 450Ml Soft Putty And 180Ml Light Body) , Stainless Steel Wire- 26 Guage (Pack Size - 1 No.) , Stainless Steel Wire- 32 Guage (Pack Size - 1 No.) , Vulcanite Trimmer (Tc) (Pack Size - 1 No.) , Micromotor Straight Handpiece For Use With Surgical Burs And Cutters Should Carry Standard/Ce Certified.Warranty - 2 Years (Pack Size - 1 No.) , Adams Plier (Pack Size - 1 No.) , Cheek Retractor - Clear (Pair Of 2) , Plier Stand - Stainless Steel (Pack Size - 1 No.) , Tweed Loop Forming Plier (Pack Size - 1 No.) , Elastics - Red (Pack Of 1000) , Elastics - 3/16-4.5 Oz. (Pack Of 1000) , Orthodontic Plastic Model Bases (Pack Size - 1 No.) , Orthodontic Stone (3Kg Pack) , Stainless Steel Wire - 0.7Mm (Spool Of 500Gms) , Anodised Aluminium Tray With Mat And Continuous Holders - Dimensions:9X7x1.25 , Micro Jewellers Forcepsstraight - Matte Finish 6 Length(Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Jewellers Forceps Angled - Matte Finish 6 Length, Less Than 5Mm Angled Arm With Less Than 1Mm Tip(Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Jewellers Forcepscurved - Matte Finish 0.2Mm Tip(Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Needle Holder - Curved - 6 Length 0.6 Mm Wide Jaw- Castroveijo Type Without Lock (Comfort Of Surgeon For Prolonged Holding, Ability Of Tip To Hold Both Microneedle And Microsuture Will Be Used As Selection Criteria) , Micro Needle Holder Castroveijo Type Without Lock Straight - 15 Cm , Vessel Clamps (Single Pair) - 2A , Vessel Clamps (Single Pair) - 2V , Vessel Clamps (Single Pair) - 3A , Vessel Clamps (Single Pair) - 3V , Vessel Clamps (Single Pair) - 4A , Vessel Clamps (Single Pair) - 4V , Tenotomy Scissors - 5/6 Curved , Tenotomy Scissors Long - 10-12 Curved , Tenotomy Scissors Long - 8 Curved , Titanium Vessel Dilator, Angled, 0.2Mm Tip , Titanium Vessel Dilator, Straight, 0.2Mm Tip , Titanium Vessel Dilator, Short Model , Micro Ring Forceps, 6 , Micro Vessel Dilator, Long Model, Straight, Matt Finish , Micro Vessel Dilator Forceps, Parallel Flattened With Round Handle, Straight, 5/6 Inch Length 0.6-1Mm Wide Tip (0.2Mm Tip) , Micro Scissors 5/6 , Straight, Blunt Tip, Round Handle Castroviejo Type , Micro Scissors 5/6 , Curved, Blunt Tip, Round Handle Castroviejo Type , Micro Scissors 5/6 , Straight, Sharp Tip, Round Handle Castroviejo Type , Micro Scissors 5/6 , Curved, Sharp Tip, Round Handle Castroviejo Type , Mixter Right Angled Forceps (Set Of 3) , Titanium Micro Forceps With Platform, 15 Cm Long , Sterilizer Box With 1 Silicon Mat , Ss Beaker With Silicon Mat , Orthopedic T-Handle , Insulated Bipolar Forceps, Adson, Fine Tip 5 (Autoclavable And Reusable, Non-Stick) , Insulated Bipolar Forceps, Adson, Fine Tip 6 (Autoclavable And Reusable, Non-Stick) , Insulated Bipolar Forceps, Bayonet, Fine Tip 6 (Autoclavable And Reusable, Non-Stick) , Insulated Bipolar Forceps, Adson, Fine Tip 5 (Autoclavable And Reusable) , Insulated Bipolar Forceps, Fine Tip 6 (Autoclavable And Reusable) , Insulated Bipolar Forceps, Bayonet, Fine Tip 6 (Autoclavable And Reusable) , Debakey Medium Vascular Size Forceps 6 , Bulldog Clamps, Atraugrip Jaws, Straight - 1Mm/2Mm Tip , Bulldog Clamps, Atraugrip Jaws, Angled - 1 Mm/2 Mm Tip , Bulldog Clamps, Atraugrip Jaws, Curved - 1 Mm/2 Mm Tip , Vessel Anastomotic Coupler- 1 Mm , Vessel Anastomotic Coupler- 1.5 Mm , Vessel Anastomotic Coupler- 2 Mm , Vessel Anastomotic Coupler- 2.5 Mm , Vessel Anastomotic Coupler- 3 Mm , Vessel Anastomotic Coupler- 3.5 Mm , Vessel Anastomotic Coupler- 4 Mm , Bulldog Disposable Vascular Clamps-Small , Bulldog Disposable Vascular Clamps-Medium , Liga Clips Micro Clips , Liga Clips Medium , Liga Clips Small , Coupler Forceps , Vessel Measuring Gauge , Fine Suction Nozzle - Size : 2 And 3 , Alar Retractor , Vessel Dilator - 0.2 Mm Tip Straight , Vessel Clamp Applicator , Micro Clamps Applicators (Forceps), 6 Long, Matt Finish (Should Be Compatible With The Vessel Clamps Provided) , Pediatric Mosquito Artery , Needle Holder Medium & Fine Tip (1Mm/2Mm) , Needle Holder Fine -12 Cm , B.P. Handle No. 3 , Head Base Ring Gel Pad - Adult Size , Head Base Ring Gel Pad - Pediatric Size , Head Base Gel Pad- Adult Size , Head Base Gel Pad- Pediatric Size , Head Neck Base Gel Pad- Adult Size , Sacral Pad- Adult Size , Heel Pad- Adult Size , Horseshoe Gel Pad Without Base - Adult Size , Knee/Arm Rest Gel Pad - Adult Size , Knee/Arm Rest Gel Pad - Pediatric Size , Gel Prone Head Rest , Chest Roll Gel Pad (Dome Positioner Prime)- Adult Size , Chest Roll Gel Pad (Dome Positioner Prime)- Pediatric Size , Universal Gel Pillows - Adult Size , Universal Gel Pillows - Pediatric Size , Neonatal Roll - Should Contain Different Sizes , Pediatric Roll- Should Contain Different Sizes , Human Acellular Matrix Preserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Meshed Size (Cm) 2X2cm , Human Acellular Matrix Preserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Meshed Size (Cm) 3X3cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 4X4cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 5X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 6X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 4X8cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Meshed Size (Cm) 5X9cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Unmeshed Size (Cm) 2X2cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Unmeshed Size (Cm) 4X4cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration. Thickness 0.2-1Mm. Unmeshed Size (Cm) 5X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Unmeshed Size (Cm) 6X7cm , Human Acellular Matrixpreserved In Propriety Glycerol Based Solution With More Than 97% Of Donor Dna Removed & Sterility Assurance Level Of 10-6. Facilitating Recipient Cellular Infiltration And Revascularization. Biohospitable & Ready To Use Without Rehydration.Thickness 0.2-1Mm. Unmeshed Size (Cm) 4X8cm , Disposable Negative Pressure Wound Therapy Kit With Multilumen Tubing And Peri Wound Protection Layer- Size: Small 1) Should Contain Hydrophobic Pu Foam Size: 11Cm X 8Cm X 3Cmadhesive Drapes 2) Should Contain Multilumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Disposable Negative Pressure Wound Therapy Kit With Multilumen Tubing And Peri Wound Protection Layer- Size: Medium 1) Should Contain Hydrophobic Pu Foam Size: 17Cm X 15Cm X 3Cm Adhesive Drapes 2) Should Contain Multilumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Disposable Negative Pressure Wound Therapy Kit With Multilumen Tubing And Peri Wound Protection Layer- Size: Large 1) Should Contain Hydrophobic Pu Foam Size: 26Cm X 15Cm X 3Cm Adhesive Drapes 2) Should Contain Multilumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Dressing With Instillation 1) Containing Multilayer Hydrophobic And Hydrocellular Foam Dressings-Size: Small (7.5Cm X 10Cm X 1.6Cm)X1 And (7.5Cm X 10Cm X 1Cm)X1 And Adhesive Drapes 2) Should Contain Multi-Lumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Dressing With Instillation 1) Containing Multilayer Hydrophobic And Hydrocellular Foam Dressings-Size:Medium (12.5 X 18 X 1.6Cm)X1 And (12.5 X 18 X 1Cm)X1 And Adhesive Drapes 2) Should Contain Multi-Lumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Dressing With Instillation 1) Containing Multilayer Hydrophobic And Hydrocellular Foam Dressings-Size: Large ( 26Cm X 15Cm X 1.6Cm)X1 And (26Cm X 15Cm X 1Cm)X1 And Adhesive Drapes 2) Should Contain Multi-Lumen Tubing, Connector, Clamp And Tube Holder 3) Should Contain Repositionable Peri-Wound Protection Layer , Negative Pressure Wound Therapy Cansiter 500Ml And Instillation Head Connector For Instillation Therapy System- 1) Should Contain 500Ml Container With Multilumen Tubing & Clamp 2) Should Contain Instillation Flow Tracker /Irrigation Head/ Casette , Dynamic Incision Management Kit (Size: 4.5Cm X 20Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Incision Management Kit (Size: 4.5Cm X 25Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Incision Management Kit (Size: 4.5Cm X 30Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Incision Management Kit (Size: 4.5Cm X 35Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3)Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4)Should Be Compatible With 100Ml-150Ml Canister , Dynamic Ulcer Management Kit (Size: 14Cm X 12Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3) Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4) Should Be Compatible With 100Ml-150Ml Canister , Dynamic Ulcer Management Kit (Size: 15Cm X 17.5Cm) Compatible With Palm Size Dynamic Incision Management System 1)Should Contain Hydrophobic Pu Foam Peel And Place Dressing 2)Low Adherent Soft Silicon Contact Layer With Additional (Adhesive) Fixation Strips 3) Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 4) Should Be Compatible With 100Ml-150Ml Canister , Container With Gel For Palm Size Dynamic Incision Management System (150Ml) 1) Transparent Container With Gel To Collect Exudate 2) Should Be Compatible With Palm Sized Negative Pressure Incision Wound Management Device (Light Weight Device Upto 200G) With Atleast 4 Pressure Settings (-50Mmhg To -125Mmhg) 3) Should Be Compatible With Dynamic Incision Management Kits , Mini Sagittal Saw Compatible With Stryker Handpiece For Craniotomy , Three Pin Head Rest For Craniotomy , Mayfield Horseshoe Headrest - Adult For Craniotomy , Mandible Bone Holding Reduction Clamp Serrated With Ratchet (Basic Bone Plating Instrument Set) , Straight Cutting Pliers - 6 Length, 2/3 Mm Wide Tip(Basic Bone Plating Instrument Set) , Bone Elevator Hoffmann Type 6 Mm (Basic Bone Plating Instrument Set) , Bone Elevator Hoffmann Type 8 Mm(Basic Bone Plating Instrument Set) , Fine Osteotome - Curved 2 Mm (For Rhinoplasty) , Fine Osteotome - Curved 4 Mm (For Rhinoplasty) , Fine Osteotome - Straight 2 Mm (For Rhinoplasty) , Fine Osteotome - Straight 4 Mm(For Rhinoplasty) , Neiverts Guarded Osteotome - Right (For Rhinoplasty) , Neiverts Guarded Osteotome - Left (For Rhinoplasty) , Guarded Osteotome Straight (For Rhinoplasty) , Guarded Osteotome Curved (For Rhinoplasty) , Joseph Bone Rasp - Cross-Serrated (For Rhinoplasty) , Joseph Bone Rasp - Double Action (For Rhinoplasty) , Cottles Glabella Rasp (For Rhinoplasty) , Mcindoes Double-Ended Periosteal Elevator (For Rhinoplasty) , Aufritch Nasal Dorsal Retractor (For Rhinoplasty) , Aschs Septal Forceps (For Rhinoplasty) , Walshams Nasal Forceps - Adult (For Rhinoplasty) , Walshams Nasal Forceps- Paediatric (For Rhinoplasty) , Tessier Osteotomes Straight 2 Mm(For Osteotomy) , Tessier Osteotomes Straight 5 Mm (For Osteotomy) , Tessier Osteotomes Straight 10Mm (For Osteotomy) , Tessier Osteotomes Straight 15 Mm (For Osteotomy) , Tessier Osteotomes Curved 2 Mm(For Osteotomy) , Tessier Osteotomes Curved 5 Mm(For Osteotomy) , Tessier Osteotomes Curved 10 Mm (For Osteotomy) , Fine Chisels Straight 2 Mm (For Osteotomy) , Fine Chisels Straight 4 Mm (For Osteotomy) , Fine Chisels Straight 6 Mm (For Osteotomy) , Fine Chisels Curved 2 Mm (For Osteotomy) , Fine Chisels Curved 4 Mm (For Osteotomy) , Fine Chisels Curved 6 Mm (For Osteotomy) , Pterygoid Osteotome 5 Mm (For Osteotomy) , Pterygoid Osteotome 10 Mm (For Osteotomy) , Pterygoid Osteotome Curved (Lefort) 1Mm, 2Mm , Bone Cutting Forceps Double Action Curved (For Osteotomy) , Arm Boardcompatible With Dr Lite Model 7000 Sb , Arm Rest For Lateral Position Compatible With Dr Lite Model 7000 Sb , Silicon Head Ring - Adult , Silicon Head Ring - Pediatrics , Fine Tendon Hook , Cats Paw Skin Retractor. , Roberts Artery Forceps , Babcock 6 Tissue Holding Forceps , Pds Plate , Russian Artery Forceps , Microinstrument Set Sterlising Case ( 20 Cm X 12 Cm) , Vessel Loop (Fine) , Micro Clip Applicator
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 34
18.
Power #11314305 Price Bid
Tender for 11 Kv Line Bifercation Amba Panel Industrial In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. (01 No Work) detail project report 71 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Dog Conductor , 11 Kv completion Poly. Pin Insulator , Stay Set , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Vcb Outgoing , Gi X-Arm Angle , 11 Kv Cable Box O/D Type Size 3X120 Sq.Mm , 11 Kv Ht Xlpe Cable 3X120 Sq.Mm. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets, Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works For Proper Completion Of Work As Directed By The Engineer-In-Charge , Grouting And Fixing Of Stay Rod Of Size 20 × 1800 Mm Complete In All Respects, Including Excavation, Providing And Laying Cement Concrete Of Size 0.60 × 0.60 × 0.30 M In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast), Backfilling, Proper Ramming, Fixing, Tightening And Nozzling Of Stay Wire With Stay Rod And Pole To The Required Tension As Per Respo Drawings/Norms, Including Providing And Fixing Stay Clamp Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts, Bolts And Loops, And All Labour, Tools & Plants And Grouting Material As Directed By The Engineer-In-Charge. , Making And Filling Of 11 Kv Xlpe Cable Jointing Kit Suitable For 3 × 120 Sq.Mm Cable, Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Engineer-In-Charge. , Installing, Testing And Commissioning Of 11 Kv Vcb Outgoing Panel Complete In All Respects, Including Mounting, Alignment, Interconnection, Control Wiring, Earthing, Nuts, Bolts, Clamps And All Associated Accessories, Labour, Tools & Plants Required For Proper Installation And Satisfactory Operation As Per Approved Drawings, Departmental Specifications And Directions Of The Engineer-In-Charge , Providing, Fabricating And Fixing Of Side Bracket Made Of M.S. Channel And M.S. Angle, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, Complete In All Respects As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work.. , Erection Of 11 Kv V-Type Cross Arm Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Erection Of 11 Kv Pin Insulator Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Erection Of 11 Kv Disc Insulator With Fittings Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of T-Off Clamp Complete With Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms/Approved Drawings, Including All Labour, Tools & Plants Required For Proper Installation And Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , 33 Kv Line Strengthing In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. (03 No Work) 17,18,19 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Acsr Dog Conductor , Earth Rod , 33 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 11 Mtr. , Stay Set , Stay Wire , Gi Wire 4Mm/8Swg , 33 Kv Cross Arm 100X50 Mm , 33 Kv Cable Box O/D Type Size 3X300 , 33 Kv Xlpe Cable Type Size 3X300 Sq.Mm. , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , 33 Kv completion Poly. Pin Insulator , Stay Wire , Gi Wire 4Mm/8Swg , Erection And Fixing Of Single Plain Cement Concrete Pole, 11 Mtr Long, For 11 Kv Line Complete In All Respects, Including Digging Of Suitable Pit, Positioning, Alignment, Dressing And Fixing Of Requisite Accessories As Per Respo Drawings/Norms, Including Providing And Fixing Of F-Bracket Made Of M.S. Flat Of Size 50 × 6 Mm, Holding Clamps Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts And Bolts, And All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting And Fixing Of Stay Rod Of Size 20 × 1800 Mm Complete In All Respects, Including Excavation, Providing And Laying Cement Concrete Of Size 0.60 × 0.60 × 0.30 M In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) As Per Drawing, Backfilling, Proper Ramming And Allied Civil Works, Including Fixing, Tightening And Nozzling Of Stay Wire With Stay Rod And Pole To The Required Tension As Per Respo Drawings/Norms, Including Providing And Fixing Stay Clamp Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts, Bolts And Loops, And All Grouting Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Earthing Of Supports With M.S. Earth Rod Of Size 20 × 2540 Mm Complete In All Respects, Including Excavation Of Pit, Driving Of M.S. Rod At A Distance Of 3.0 M From The Support And 0.5 M Below Ground Level, And Connection Of Support With Earth Electrode Using Suitable Size G.I. Wire And Earthing Lugs, Including Providing And Fixing Of Proper Size Nuts, Bolts And All Associated Accessories, As Per Respo Drawings/Norms, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting Of Plain Cement Concrete Supports Complete In All Respects With Cement Concrete In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) In Block Size 450 × 450 Mm Up To 1/6Th Of The Full Length Of Support Below Ground Level, Including Providing 300 Mm Plinth Above Ground Level With Cement Concrete In Ratio 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Grit) With Proper Mufting As Per Approved Drawing, Including Backfilling, Proper Ramming And Providing All Required Grouting Materials, Labour, Tools & Plants For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of 6 Inch Dia Class-B G.I. Pipe Over 33 Kv 3 × 300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting On Double Pole Structure, Complete In All Respects, Including Providing And Fixing Of Suitable Clamps, Sealing Of Top And Bottom Ends Of Pipe, Burying One End Of Pipe Approximately 500 Mm Below Ground Level, Mounting And Clamping Of Cable On Double Pole Structure, And Making Connection With Overhead Line At Both Ends, Including All Labour, Tools & Plants And Associated Materials Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Making And Filling Of 33 Kv Xlpe Cable Jointing Kit Suitable For 3 × 300 Sq.Mm Cable Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Erection Of 33 Kv V-Type Cross Arm Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Trenchless Laying Of 200 Mm O/D Pe-80, Pn-4 Grade Uv Stabilized Hdpe Pipe Conforming To Relevant Is Specifications In Standard 6 Mtr Length For Laying Of Underground Cable, Complete In All Respects As Per Respo Norms, Including Cost Of Hdpe Pipe, Jointing, Handling, Labour, Tools & Plants And All Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Laying Of 33 Kv Xlpe Cable Of Size 3 × 300 Sq.Mm Underground Through Hdpe Pipe Complete In All Respects, Including Pulling, Dressing, Alignment And Leaving Spare Cable In Loop Shape At Both Ends As Per Respo Norms, Including All Labour, Tools & Plants And Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Holding Clamp Complete In All Respects, Including Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms/Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Jumpering And Line Energisation Work Complete In All Respects, Including Proper Connection, Tightening, Testing And Commissioning As Per Respo Norms/Approved Drawings, Including All Labour, Tools & Plants And Associated Materials Required For Safe And Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Safe De-Erection And Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , 11 Kv Line Strengthing In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. (11 No Work) detail project report 61,62,63,64,65,66,67,68,69,70,71 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Earth Rod , 11 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 8.5 Mtr. , Plain Cement Concrete Pole 11 Mtr. , Stay Set , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Gi Wire 10Swg , Gi X-Arm Angle , 11 Kv Vtype Steel Cross Arm , 33 Kv Cable Box O/D Type Size 3X300 , 11 Kv Cable Box O/D Type Size 3X120 Sq.Mm , 33 Kv Xlpe Cable Type Size 3X300 Sq.Mm. , 11 Kv Ht Xlpe Cable 3X120 Sq.Mm. , 11 Kv Xlpe Cable 3X300 Sq.Mm. , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Disc Fitting 45 Kn , 11 Kv completion Poly. Pin Insulator , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Gi Wire 10Swg , Gi X-Arm Angle , 33 Kv Xlpe Cable Type Size 3X300 Sq.Mm. , 11 Kv Ht Xlpe Cable 3X120 Sq.Mm. , Erection And Fixing Of Single Plain Cement Concrete Pole, 8.50 Mtr Long, For 11 Kv Line Complete In All Respects, Including Digging Of Suitable Pit, Positioning, Alignment And Fixing Of Requisite Accessories As Per Respo Drawings/Norms, Including Providing And Fixing Of F-Bracket Made Of M.S. Flat Of Size 50 × 6 Mm And Holding Clamps Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts And Bolts, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Weasel Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Rabbit Conductor Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And E-Brackets Wherever Required, As Per Respo/Drawing Norms, Including All Labour, Tools & Plants, Handling, Hoisting And Allied Works Required For Proper Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting And Fixing Of Stay Rod Of Size 20 × 1800 Mm Complete In All Respects, Including Excavation, Providing And Laying Cement Concrete Of Size 0.60 × 0.60 × 0.30 M In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) As Per Approved Drawing, Including Backfilling, Proper Ramming And Allied Works, Fixing, Tightening And Nozzling Of Stay Wire With Stay Rod And Pole To The Required Tension As Per Respo Drawings/Norms, Including Providing And Fixing Stay Clamp Made Of M.S. Flat Of Size 50 × 6 Mm With Suitable Nuts, Bolts And Loops, And All Grouting Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Earthing Of Supports With M.S. Earth Rod Of Size 20 × 2540 Mm Complete In All Respects, Including Excavation Of Pit, Driving Of M.S. Rod At A Distance Of 3.0 M From The Support And 0.5 M Below Ground Level, And Connection Of Support With Earth Electrode Using Suitable Size G.I. Wire And Earthing Lugs, Including Providing And Fixing Of Proper Size Nuts, Bolts And All Associated Accessories, As Per Respo Drawings/Norms, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Grouting Of Plain Cement Concrete Supports Complete In All Respects With Cement Concrete In Ratio 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded 40 Mm Brick Ballast) In Block Size 450 × 450 Mm Up To 1/6Th Of The Full Length Of Support Below Ground Level, Including Providing 300 Mm Plinth Above Ground Level With Cement Concrete In Ratio 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Grit) With Proper Mufting As Per Approved Drawing, Including Backfilling, Proper Ramming And Providing All Required Grouting Materials, Labour, Tools & Plants For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of 6 Inch Dia Class-B G.I. Pipe Over 33 Kv 3 × 300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting On Double Pole Structure, Complete In All Respects, Including Providing And Fixing Of Suitable Clamps, Sealing Of Top And Bottom Ends Of Pipe, Burying One End Of Pipe Approximately 500 Mm Below Ground Level, Mounting And Clamping Of Cable On Double Pole Structure, And Making Connection With Overhead Line At Both Ends, Including All Labour, Tools & Plants And Associated Materials Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Making And Filling Of 33 Kv Xlpe Cable Jointing Kit Suitable For 3 × 300 Sq.Mm Cable Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Making And Filling Of 11 Kv Xlpe Cable Jointing Kit Suitable For 3 × 120 Sq.Mm Cable Complete In All Respects, Including Proper Plumbing And Taping Of Xlpe Cable, Providing, Fixing And Crimping Of Suitable Size Approved Quality Lugs, Including Cost Of Lugs, Tapes And All Jointing Materials, Labour, Tools & Plants Required For Satisfactory Completion Of Work As Per Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Providing, Fabricating And Fixing Of Side Bracket Made Of M.S. Channel And M.S. Angle Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Erection Of 33 Kv V-Type Cross Arm Complete In All Respects, Including Providing And Fixing Of Holding Clamps, Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Trenchless Laying Of 200 Mm O/D Pe-80, Pn-4 Grade Uv Stabilized Hdpe Pipe Conforming To Relevant Is Specifications In Standard 6 Mtr Length For Laying Of Underground Cable, Complete In All Respects As Per Respo Norms, Including Cost Of Hdpe Pipe, Jointing, Handling, Labour, Tools & Plants And All Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying Of 11 Kv Xlpe Cable Of Size 3 × 125 Sq.Mm Underground Through Hdpe Pipe Complete In All Respects, Including Pulling, Dressing, Alignment And Leaving Spare Cable In Loop Shape At Both Ends As Per Respo Norms, Including All Labour, Tools & Plants And Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Laying Of 33 Kv Xlpe Cable Of Size 3 × 300 Sq.Mm Underground Through Hdpe Pipe Complete In All Respects, Including Pulling, Dressing, Alignment And Leaving Spare Cable In Loop Shape At Both Ends As Per Respo Norms, Including All Labour, Tools & Plants And Associated Works Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Danger Board Complete In All Respects, Including Providing And Fixing Of All Required Accessories Such As Suitable Clamps, Nuts, Bolts And Allied Materials, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Stone Pad Of Size 300 × 300 × 75 Mm Complete In All Respects, As Per Respo Norms And Approved Drawings, Including Excavation, Dressing, Leveling, Proper Positioning, Packing And Fixing With All Labour, Tools & Plants And Associated Materials Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of F-Clamp Complete In All Respects, Including Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Of Holding Clamp Complete In All Respects, Including Suitable Nuts, Bolts And All Associated Accessories, As Per Respo Norms And Approved Drawings, Including All Labour, Tools & Plants Required For Satisfactory Completion Of Work As Directed By The Site In-Charge/Engineer-In-Charge. , Providing And Fixing Top Channel Of Approved Make And Required Dimensions Conforming To Respo Norms And Specifications; Work Includes Material Supply, Transport, Unloading, Cutting To Size, Hoisting, Alignment, And Rigidly Securing In Position With Approved Fasteners, Hardware, And Scaffolding At Any Height Or Location, Complete In All Respects As Per The Manufacturers Guidelines And To The Entire Satisfaction And Direction Of The Site In-Charge. , Providing And Fixing G.I. Barbed Wire Fencing Of Approved Make, Weight, And Gauge Conforming Strictly To Respo Norms And Standard Technical Specifications; Work Includes Supplying, Transporting, And Unrolling Required Lines Of Horizontal And Diagonal Strands, Tightly Stretching, Aligning, And Securely Fixing To Concrete/Steel/Stone Posts Using Approved G.I. Staples, Binding Wire, Or Fasteners, Including All Leads, Lifts, Necessary Scaffolding, Tools, Tackles, And Labor Required To Complete The Installation In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Fixing M.S. / G.I. / High-Tensile Nut And Bolt Assemblies Of Approved Make, Grade, And Required Diameters/Lengths Conforming Strictly To Respo Norms And Standard Technical Specifications; Work Includes Supply, Transport, Positioning, Aligning, And Rigidly Tightening To The Specified Torque Using Appropriate Washers (Plain/Spring) And Tools, Including All Necessary Scaffolding, Labor, Leads, And Lifts Required To Complete The Fastening Work In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Erection Of Structural Steel Bracing Sets Of Size 4.3 M X 4.3 M Fabricated From M.S. Angle Sections Of Size 65 Mm X 65 Mm X 6 Mm, Conforming Strictly To Respo Norms And Technical Specifications; Work Includes Hoisting, Lifting, Proper Positioning, Leveling, Aligning, And Rigidly Securing The Assembly Using Approved Holding Clamps, Structural Nuts, Bolts, And Washers Of Required Sizes, Including The Cost Of All Fastening Hardware, Necessary Tools, Tackles, Scaffolding, Staging, Leads, Lifts, And Labor Required To Complete The Installation In All Respects As Per Standard Engineering Practices And Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , 33 Kv Protection Of Sub-Station In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur.(01 No Work) detail project report 39 , Carriage Of 33 Kv Vcb From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Carriage Of 33 Kv Ct Out Door From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , 33 Kv Installation Of Vcb , 33 Kv Installation Of Ct Outdoor , Providing & Making And Fixing Of Side Breckit By Ms. Channel, Ms Angle By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Erecetion Of 11 Kv Disc Insulator With Fitting By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Providing And Fixing Of Copper Control Cable Size 2X2.25 Sq.Mm. , As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing, Installing, Testing, And Commissioning Of Maintenance-Free Water Level Chemical Earthing System Conforming To Is:3043 Specifications For Distribution Transformers And Substations; Scope Includes Boring An Earth Pit Of Required Depth, Inserting A Heavy-Duty Copper-Bonded Steel Electrode Or Gi Pipe (Minimum 3-Meter Length), Backfilling The Pit With Eco-Friendly Moisture-Retaining Earth Enhancement Chemical Compound, Providing A Dedicated Funnel Arrangement With A Perforated Gi Watering Pipe Running To The Root Of The Electrode For Manual Moisture Replenishment, Constructing A Rigid Brick Masonry/Pre-Cast Concrete Inspection Chamber With A Heavy-Duty Removable Cover Plate At Ground Level, And Establishing Secure Structural Connections To The Equipment Earth Grid Using Proper Size Gi/Copper Strips, Inclusive Of All Excavation In Any Soil Strata, Backfilling, Ramming, Hardware, Labor, Tools, Tackles, And Transportation, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Providing And Fixing Of Ms Channel As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Ms Angle As Per Respo/Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo/Norms And As Per Direction Of Site Incharge. , 33 Kv Vcb In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Garh Under Edc Hapur. ( 07 No Work) detail project report 20,21,22,23,24,25,26 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , 33 Kv Ct Outdoor Ctr 200/100/1 , Control Pannel 33 Kv Double T/F , 33 Kv Outdoor Type Vcb , Providing, Fabricating, And Fixing M.S. Side Brackets Of Required Design And Dimensions, Utilizing Approved M.S. Channel And M.S. Angle Sections, Conforming Strictly To Respo Norms And Standard Technical Specifications; Scope Of Work Includes Material Supply, Cutting, Welding, Drilling, Rust-Preventive Primer Coating, Hoisting, Proper Alignment, And Rigidly Securing The Brackets In Position Using Appropriate Holding Clamps, Nuts, Bolts, And Washers, Inclusive Of All Necessary Staging, Scaffolding, Tools, Tackles, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Testing, And Commissioning Of Pvc/Xlpe Insulated, Pvc Sheathed 2 Core X 2.25 Sq.Mm. Copper Control Cable (Armored/Unarmored) Of Approved Make And Grade, Conforming Strictly To Respo Norms And Relevant Is Specifications; Work Includes Supply, Transportation, Storage, Unrolling, Straightening, And Laying Of Cable Through Existing Pipes, Conduits, Cable Trays, Or Trenches, Including Dressing, Clamping, Structural Clipping, Proper Tag Identification, End-Termination Using Required Size Copper Lugs, Glands, Glands-Earthing, And Testing (Insulation Resistance And Continuity Tests), Inclusive Of All Labor, Tools, Tackles, Scaffolding, Leads, And Lifts, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Testing, And Commissioning Of Pvc/Xlpe Insulated, Pvc Sheathed 4 Core X 2.25 Sq.Mm. Copper Control Cable (Armored/Unarmored) Of Approved Make And Grade, Conforming Strictly To Respo Norms And Relevant Engineering Specifications; Work Includes Supply, Transportation, Storage, Unrolling, Straightening, And Laying Of Cable Through Existing Pipes, Conduits, Cable Trays, Or Trenches, Including Systematic Dressing, Clamping, Structural Clipping, Proper Tag Identification, End-Termination Using Required Size Copper Lugs, Glands, Glands-Earthing, And Necessary Testing (Insulation Resistance And Continuity Tests), Inclusive Of All Labor, Tools, Tackles, Scaffolding, Staging, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Construction Of Vacuum Circuit Breaker (Vcb) Plinth Of Size 2.0 M X 2.0 M X 1.5 M Suitable For A 250 Kva Transformer/System, Executed Strictly As Per Approved Structural Drawings And Respo Norms; Work Includes Excavation, Providing And Laying Cement Concrete (Cc) 1:4:8 (1 Cement : 4 Sand : 8 Graded Brick Ballast) In Foundation, Constructing Side Walls Using 1St Class Brickwork In Cement Mortar 1:4 (1 Cement : 4 Fine Sand), Applying 12 Mm Thick Cement Plaster 1:4 (1 Cement : 4 Fine Sand) On Exposed Surfaces, Backfilling Inside The Plinth With Brick Ballast Including Systematic Watering And Heavy Ramming/Compaction, And Casting A Finished Reinforced Cement Concrete (Rcc) Top Slab In 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Including Necessary Reinforcement Steel, Shuttering, Centering, And Curing; Rate Shall Be Fully Inclusive Of All Material Supply, Transport, Machinery, Scaffolding, Labor, Leads, And Lifts, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Testing, And Commissioning Of Pvc/Xlpe Insulated, Pvc Sheathed 6 Core X 2.25 Sq.Mm. Copper Control Cable (Armored/Unarmored) Of Approved Make And Grade, Conforming Strictly To Respo Norms And Relevant Engineering Specifications; Work Includes Supply, Transportation, Storage, Unrolling, Straightening, And Systematic Laying Of Cable Through Existing Pipes, Conduits, Cable Trays, Or Trenches, Including Dressing, Clamping, Structural Clipping, Proper Tag Identification, End-Termination Using Required Size Copper Lugs, Compression Glands, Glands-Earthing, And Mandatory Pre-Commissioning Testing (Insulation Resistance And Continuity Tests), Inclusive Of All Labor, Tools, Tackles, Scaffolding, Staging, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Installation Of 100 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Garh, Under Edc Hapur (No. Of Work 5) 121,122,123,124,128 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Weasel Conductor , Earth Rod , A.B Cable L.T (3X120+1X95+1X16) Sq Mm , D.O Fuse Set , 11 Kv Tpmo Switch , 11 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 8.5 Mtr. , Plain Cement Concrete Pole 11 Mtr. , Stay Set , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Lt Alu. Xlpe Cable 3.5X150 Sq. Mm , Gi Wire 4Mm/8Swg , Gi X-Arm Angle , 100 Kva Transformer , Lt Xlpe Cable 3.5X150 Sq.Mm. , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Disc Fitting 45 Kn , 11 Kv completion Poly. Pin Insulator , Stay Wire , 11 Kv completion Poly. Disc Insulator 45 Kn , Lt Alu. Xlpe Cable 3.5X150 Sq. Mm , Gi Wire 4Mm/8Swg , Gi X-Arm Angle , Lt Xlpe Cable 3.5X150 Sq.Mm. , Erection Of Double Pole (Dp) Structure Utilizing 8.5-Meter Long Plain Cement Concrete Poles, Complete With All Necessary Structural Accessories And Conforming Strictly To Approved Respo Drawings And Norms; Work Includes Excavation, Pole Erection, Alignment, Backfilling, And Fabrication, Supply, And Fixing Of M.S. Top And Dropper Channels, M.S. Tif Angles, And E-Brackets; Installation Of 11 Kv Pin Insulators With Pins And Disc Insulators With Appropriate Hardware/Disc Fittings; Providing And Fixing Structural Stays, Bracings, And Assemblies Fabricated From M.S. Flat Of Size 50 Mm X 6 Mm, Secured Tightly With Proper Size Nuts, Bolts, And Washers; Execution Of Complete Standard Jumpering, Binding, And Pg Clamping Work Using Appropriate Conductors/Accessories To Ensure Electrical Continuity; Rate Shall Be Fully Inclusive Of All Structural Steel, Hardware, Insulation Materials, Machinery, Tools, Tackles, Scaffolding, Labor, Leads, And Lifts At Any Height, Complete In All Respects As Per Standard Engineering Practices Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Erection Of Double Pole (Dp) Structure Utilizing 11-Meter Long Plain Cement Concrete Poles, Complete With All Structural Accessories And Conforming Strictly To Approved Respo Drawings And Norms; Work Includes Excavation, Pole Erection, Leveling, Alignment, And Backfilling; Fabrication, Supply, And Fixing Of M.S. Top And Dropper Channels, M.S. Tf Angles, And E-Brackets; Installation Of 11 Kv Pin Insulators With Pins And Disc Insulators With Appropriate Hardware/Disc Fittings; Providing And Fixing Structural Bracings, Ties, And Support Assemblies Fabricated From M.S. Flat Of Size 50 Mm X 6 Mm, Secured Tightly With Proper Size Nuts, Bolts, And Washers; Execution Of Complete Standard Jumpering, Binding, And Pg Clamping Work Using Appropriate Conductors To Ensure Reliable Electrical Continuity; Rate Shall Be Fully Inclusive Of All Structural Steel Fabrication, Hardware, Insulation Components, Handling Machinery, Tools, Tackles, Scaffolding, Labor, Leads, And Lifts At Any Height, Complete In All Respects As Per Standard Electrical Engineering Practices Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Laying Stone Pad Base Blocks Of Size 300 Mm X 300 Mm X 75 Mm Of Approved Quality And Strength, Conforming Strictly To Respo Drawings And Norms; Work Includes Supply, Transportation, Storage, Necessary Excavation Or Surface Preparation, Leveling, And Dressing Of Soil, Proper Positioning, Rammed Leveling, And Alignment Of The Stone Pads Beneath Poles, Structures, Or Stays To Act As A Solid Bearing Foundation, Including The Cost Of All Materials, Machinery, Tools, Tackles, Handling Labor, Leads, And Lifts At Any Location, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Fixing Heavy-Duty M.S. Holding Clamps Fabricated To Required Profiles And Dimensions, Complete With Matching Nut, Bolt, And Washer Assemblies Of Approved Make And Size, Conforming Strictly To Respo Drawings And Norms; Work Includes Material Supply, Transport, Proper Positioning Around Poles, Structures, Or Machinery, Alignment, And Rigid Fastening/Tightening To Specified Torque, Inclusive Of All Anti-Corrosive Primer/Paint Coatings, Necessary Tools, Tackles, Scaffolding, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing And Fixing Heavy-Duty M.S. Clamps Fabricated To Required Design, Shape, And Dimensions, Complete With Appropriate Size Nut, Bolt, And Washer Assemblies Of Approved Make, Conforming Strictly To Respo Drawings And Norms; Work Includes Material Supply, Transportation, Precise Positioning, Alignment, And Rigid Tightening Around Poles, Structural Members, Or Equipment, Inclusive Of Rust-Preventive Primer And Paint Coatings, All Necessary Tools, Tackles, Scaffolding, Staging, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Safe Handling, Lifting, Positioning, And Installation Of A 100 Kva Distribution Transformer Onto An Existing Lt Sub-Station Double Pole Structure Or Concrete Plinth, Utilizing An Appropriate Capacity Crane, Mechanical Hoists, Or Manual Labor With All Safety Equipment; Work Includes Proper Alignment, Leveling, Structural Securing, And Providing And Crimping Appropriate Sizes Of Heavy-Duty Aluminium Long Barrel Lugs For All Ht (High Tension) And Lt (Low Tension) Terminal Connections To Ensure Low-Resistance Termination, Inclusive Of All Handling Machinery, Rigging Tools, Safety Tackles, Scaffolding, Specialized Labor, Leads, And Lifts At Any Height, Executed Complete In All Respects As Per Standard Electrical Engineering Practices And Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing, Laying, Stringing, Testing, And Commissioning Of Xlpe Insulated Lt Aerial Bunched Cable (Abc) Of Size 3X120 + 1X95 + 1X16 Sq.Mm. (Comprising Three Phase Conductors, One Insulated Messenger Wire, And One Street Light Conductor) Of Approved Make, Conforming Strictly To Respo Norms And Relevant Standard Specifications; Work Includes Unrolling, Straightening, Hoisting, And Tensioning Of The Cable Along Poles/Structures Using Appropriate Sagging Equipment, Providing And Fixing Necessary Hardware Including Suspension Clamps, Dead-End/Anchoring Clamps, I-Hooks, Pole Brackets, Stainless Steel Strapping With Buckles, And Insulation Piercing Connectors (Ipcs) For Jointing Or Tapping; Scope Covers Proper Dressing, Securing, And Mid-Span Clamping To Maintain Standard Clearances, Inclusive Of All Machinery, Winches, Pulling Tackles, Scaffolding, Safety Gear, Labor, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Fuse/Do Fuse Set Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Tf With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Tpmo Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Ms Angle & Ms Channel All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Ms Channel , Ms Angle , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Garh, Under Edc Hapur 117, 118, 119,120, 125, 126, 127 , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Disc Fitting 45 Kn , Acsr Weasel Conductor , Earth Rod , A.B Cable L.T (3X120+1X95+1X16) Sq Mm , D.O Fuse Set , 11 Kv Tpmo Switch , 250 Kva 11/0.4 Kv Transformer New , 11 Kv completion Poly. Pin Insulator , Plain Cement Concrete Pole 8.5 Mtr. , Plain Cement Concrete Pole 11 Mtr. , Stay Set , 11 Kv completion Poly. Disc Insulator 45 Kn , Lt Alu. Xlpe Cable 3.5X400 Sq. Mm , Erection And Fixing Of The Following Materials Complete In All Respects, Including All Required T&P, Labour, Handling, Lifting, Fastening And Allied Works For Proper Installation As Per Departmental Specifications, Respo Norms And Directions Of The Site In-Charge/Engineer-In-Charge. , Disc Fitting 45 Kn , 11 Kv completion Poly. Pin Insulator , 11 Kv completion Poly. Disc Insulator 45 Kn , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 11 Mtr. Long, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Safely Installation Of 250 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth, As Per Direction Of Site Incharge. , Laying Of Lt Alu. Xlpe Cable Al. 3.5X400 Sqmm By Porviding Al Lug And Panching With Cremping Tool Complection Work Properly, As Per Respo/Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm By Providing Suspension Clamp Dead End Clamp, I-Hook Etc And Completion Work Properly, As Per Respo Norms, And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Construction Of Tf Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mt.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Construction Of Safety Fencing (Ms) For Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Anglen-Iron To Be Fitted On Vertical Posts. Pickets (I Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 75X75x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Fuse/Do Fuse Set Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv Tpmo Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Holding Clamp With Nut & Bolt As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Alu. Lug 240 Sq.Mm.(Ls) Off Size As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing, Installing, Testing, And Commissioning Of Heavy-Duty Tail-Less Fuse Units (Lt Distribution/Bushing Bars) Of Approved Make, Rating, And Specifications Conforming Strictly To Respo Norms And Standard Electrical Designs; Work Includes Material Supply, Hoisting, Proper Alignment, Mounting Onto The Distribution Transformer Lt Bushings Or Dp Structure Steelwork, Making Solid, Low-Resistance Direct Connections, And Providing All Necessary Copper/Aluminium Links, Hardware, Nuts, Bolts, And Washers, Inclusive Of All Safety Gear, Specialized Labor, Tools, Tackles, Leads, And Lifts At Any Height, Complete In All Respects Under The Strict Direction And Entire Satisfaction Of The Site In-Charge. , Providing & Fixing Of Ms Angle & Ms Channel All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing, Installing, Testing, And Commissioning Of Maintenance-Free Chemical Earthing System Of Approved Make And Design, Conforming Strictly To Respo Norms, Is 3043, And Ieee 80 Standards; Work Includes Augering/Boring An Earth Pit Of Required Diameter And Depth, Supplying And Lowering A High-Conductivity Copper-Bonded Steel / G.I. Earth Electrode Of Specified Length And Diameter, Completely Backfilling The Surrounding Void With Moisture-Retaining, Non-Corrosive Earth Enhancement Chemical Compound (Bentonite/Carbon Based) Mixed With Water As Per Manufacturer Guidelines, Constructing A Brick Masonry / Pre-Cast Concrete Inspection Chamber With A Heavy-Duty Ci/Concrete Cover Plate On Top, Providing An Integrated Copper/G.I. Terminal Busbar With Required Hardware For Down-Conductor Connectivity, And Conducting Final Earth Resistance Testing To Ensure Values Remain Well Within Permissible Electrical Limits, Inclusive Of All Excavation, Materials, Labor, Tools, And Tackles, Complete Under The Direction And Entire Satisfaction Of The Site In-Charge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
20.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
21.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
22.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
25.
Water Resources and Irrigation #11220406 Price Bid
Tender for Excavation In Dumped Stones Or Malba Including Stacking Of Serviceable And Unserviceable Material Separately And Disposal Of Unserviceable Material, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Material To Be Neatly Dressed. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Supplying Of Good Earth In Rough Excavation, Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks For Filling Up Ground Depresssion Lead Upto 15 Km And Lift Upto 1.50 M. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Finished With A Floating Coat Of Neat Cement Of Mix :1:4 (1 Cement: 4 Fine Sand) , Providing And Laying Class Sn-8 Dwc Structed Wall Polyethylene Piping System (Pipe With Online/Offline Coupler And Elastomeric Sealing Ring) With Non Smooth External Annular Corrugated And Smooth Internal Surface (Double Wall) For Non Pressure Underground Sewerage And Drainage Application As Conforming To Is 16098 (Part-Ii): 2013, This Includes Jointing Of Pipes & Fittings With Solvent Cement,Thermostat Sealing, & Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. 600 Mm Nominal Inner Dia Pipes , Constructing Brick Masonry Road Gully Chamber 45X45x77.5 Cm With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Precast Reinforced Cement Concrete Vertical Grating Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Circular Manhole 1.22 M Internal Dia At Bottom And 0.56 M Dia At Top In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Inside Cement Plaster 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement Foundation Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) And Making Necessary Channel In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement, All Complete As Per Standard Design : 1.68 M Deep With Steel Fibre Reinforced Concrete Cover And Frame (Heavy Duty Hd-20 Grade Designation) 560 Mm Internal Diameter Conforming To I.S. 12592, Total Weight Of Cover And Frame To Be Not Less Than 182 Kg. Fixed In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Centering, Shuttering All Complete. (Excavation, Foot Rests And 12 Mm Thick Cement Plaster At The External Surface Shall Be Paid For Separately) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Laying Non-Pressure Np4 Class (Heavy Duty) Reinforced Cement Concrete Pipes Including Collars / Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete : 1000 Mm Dia. Reinforced Cement Concrete Pipes (Laying By Manual/Mechanical Means). , Providing And Laying Non-Pressure Np2 Class (Light Duty) Reinforced Cement Concrete Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement : 2 Fine Sand) Including Testing Of Joints Etc. Complete :300 Mm Dia. Reinforced Cement Concrete Pipe , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed Plain Cement Concrete, With Cement Content As Per Approved Design Mix And Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Plain Cement Concrete Work, Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying And Curing, Xcluding The Cost Of Centering, Shuttering And Finishing, Including Cost Of Curing, Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer-In-Charge. Note : Excess/Less Cement Used Than Specified In This Item Is Payable/ Recoverable Separately M-10 Grade Plain Cement Concrete (Cement Content Considered @ 220 Kg/Cum) , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For:Foundations,Footings,Bases Of Columns,Etc.Formass Concrete , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For: Walls(Anythickness) Including Attached Pilasters,Butteresses, Plinth And String Courses Etc. , Centering And Shuttering Including Strutting,Propping Etc.And Removal Of Form For:Suspended Floors,Roofs,Landings,Balconies And Access Platform. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately).All Works Upto Plinth Level , Steel Reinforcement For R.C.C.Work Including Straightening,Cutting, Bending,Placing In Position And Bind In Gall Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate)Finished With A Floating Coat Of Neat Cement,Including Cementslurry,But Excluding The Cost Of Nosingofsteps Etc.Complete. 40Mm Thick With 20Mm Nominal Size Stone Aggregate. , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Providing And Laying Rmc Of M-30 Grade By Using Minimum 400 Kg. Of Cement (43 Grade Opc) Per Cum Of Concrete In Roads/Streets Manufactured In Automatic Rmc Plant Using Coarse Sand And Graded Stone Aggregate Of 20 Mm Nominal Size In Appropriate Proportion As Per Approved Design Criteria Including Transportation To Site In Transit Mixer, Including Cost Of Concrete To Improve Workability Wit Out Impairing Strength And Durability As Per Specification Including Spreading And Compacting Mechanically By Using Needle And Surface Vibrators, Leveling To Required Slops And Camber, Finishing By Contractor/ Expansion, Construction Of Cross/ Longitudinal Joints With Approved Joints Filler And Sealants, Etc. Complete As Per Direction Of Engineer-In-Charge(Cost Of Joint Filler & Sealants Shall Be Paid For Separately Under Relevant Item). Note: Cement Content Considered In M-30 Is @400 Kg/Cum. Rc Using Minimum Cement @400 Kg/Cum. Cement Concrete Manufactured In Automatic Batching Plant (Rc Plant) Including Transportation To Site In Transit Mixer. , Preparation And Consolidation Of Sub Grade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Sub Grade And Disposal Ofsurplus Earthwith Lead Upto 50 Metres. , Supplying And Stacking At Site. 90 Mm To 45 Mm Size Stone Aggregate , Supplying And Stacking At Site.63 Mm To 45 Mm Size Stone Aggregate , Supplying And Stacking At Site.53 Mm To 22.4 Mm Size Stone Aggregate , Supplying And Stacking At Site.Moorum , Supplying And Stacking At Site. Stone Screening 13.2 Mm Nominal Size (Typea) , Supplying And Stacking At Site.Stone Screening 11.2 Mm Nominal Size (Type B) , Laying, Spreading And Compacting Stone Aggregate Of Specified Sizes To Wbm Specifications In Uniform Thickness, Hand Picking, Rolling With 3 Wheeled Road/Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening /Binding Material To Fill Up Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density . , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications : On W.B.M. @ 0.75 Kg / Sqm , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specificatons And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Of Grade Vg-30 @ 3.50% (Percentage By Weight Of Total Mix) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity. , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade Vg - 10, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications :On Bituminous Surface @ 0.50 Kg / Sqm , Providing And Laying Bituminous Concrete Using Crushed Stone Aggregates Of Specified Grading, Premixed With Bituminous Binder And Filler, Transporting The Hot Mix To Work Site By Tippers, Laying With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desiredcompaction And Density As Per Specification, Complete And As Per Directions Of Engineer-In-Charge. 40/50 Mm Compacted Thickness With Bitumen Of Grade Vg-30 @ 5.5% (Percentage By Weight Of Total Mix) And Lime Filler @ 3% (Percentage By Weight Of Aggregate) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming Andwatering, Lead Up To 50 And For All Lift. , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
26.
Heavy Industries and Public Enterprises #11214042 AOC
Purchase Of Projection System, Shows And Associated Items. , Purchase Of Projection System, Shows And Associated Items. (Please Enter Rates As Per Annexure-G Of Dnit) , As Per Clause No.: 3.1: Charges For Total Number Of 2D 4K_Uhd Projectors Being Offered Including Cables, Connectors And Other Accessories , As Per Clause No.: 3.1 (A)11: Charges For Total Number Of Professional Customized Fish Lenses Being Offered With Accessories , As Per Clause No.: 3.1 (A)11: Charges For Complete Physical Masking Setup System For Projector Output , As Per Clause No. 3.3: Charges For Complete Computer Hardware System To Be Used As Operator & Maintenance Console, Graphic Handling Includingoperating System, Accessories, Other Applications Etc. , As Per Clause No. 3.5: Charges For Full Dome Show Player Software (For Single User License) , As Per Clause No. 3.5: Charges For Sky-Simulation Software (For Single User License) , As Per Clause No. 3.2: Charges Forcomplete Automatic Blending And Geometry Correction Unit , As Per Clause No. 4.5 : Charges For Staff Training , As Per Clause No. 4.10 : Charges For One Additional Pre-Configured Computer Cpu Ready For Running Shows , As Per Clause No. 4.10 : Charges For One Additional Pre-Configured Projector With Accessories Ready For Running Shows , As Per Clause No. 4.6 : Charges For Pre-Configured Tablet-Pc And Associated Components To Be Used As An Portable Operator’S Interface , As Per Clause No. 4.8: Charges For Dome Cleaning, Replacement Of Exiting Insulation Sheets With Acoustic Sheets Of Poly-Synth Material And Associated Works , As Per Clause No. 4.2 : Charges For Complete Led Cove Lighting System With Dmx System With Accessories , As Per Clause No. 4.3 : Charges For Complete 5.1 Audio System With Accessories , As Per Clause No : 3.9 And 4.4, If Any Modification/Up-Gradation Is Required In The Existing Electrical & Civil Infrastructure, Then Please Mention Such Charges As Per Details Submitted In The Technical Bid , As Per Scope Of Work: Service Charges For Supply, Installation, Testing And Commissioning Of The Whole System As Per Scope Of Work Which Includes Projectors With Calibration, Alignment And Physical Masking , Fish Eye Lenses, Computer Systems (Hardware And Software), Led Lighting And 5.1 Audio Systemetc. , As Per Clause No. 4.9 : Year Wise Charges For Onsite Comprehensive Annual Maintenance Contract (Cmc) Of The Complete System Along With Additional Computer And Projector (After Expiry Of 5 Years Of Purchase Warranty) , 6Th Year , 7Th Year , 8Th Year , 9Th Year , 10Th Year
Contract Date: Jun 02, 2026 Contract Value : 2.42 Crore
Government Departments No of Bidders 2
27.
Power #11209263 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; 3517556; Service Provider - Carriage Of Cmr/Ash By Mechanical Transport Including Loading, Unloading And Stacking Upto 5 Km Distance From Power House Area To Ash Ponds At Ptpp Parichha. Payment To Be Made After Deducting Voids As Per Cpwd Specfication Or As Decided By Engineer In Charge. , Earth/Ash Work In Excavation In Earth Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5M; Disposed Earth To Be Levelled And Neatly Dressed , Placing Of Precast Rcc Planks In Decantation Well Including Its Carrige And Putting It Into Slott Including All Labour T&P Etc. Required For Proper Completion Of Work. , Providing And Laying Empty Cement Plastic Bags Filling The Same With Ash Having Capacity Of 50Kg And Stiching The Same With Sutali, Laying With Ash Pond Area As Per Instruction Of Engineer Incharge. , Engaging Jcb/Hydra Machine On Hire Bases Including Hire Fuel Driver Helper Etc. Complete. , Dry Stone Pitching 22.5/30 Cm Thick Including Supply Of Stones And Preparing Surface Filling From Fly Ash With Watering & Compection Complete Including Carriage From Coal Handling Area.(Boulder Free Of Cost From Chd Area In Plant) , Spreading Of Cmr/Ash/Earth By Opening Of Stack Including Dressing Watering Compaction/Ramming Etc. Complete For Proper Completion Of Work As Per Direction Of Engineer In Charge Of The Work. Payment To Be Made On Compacted Quantity. , Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood,Trees And Saplings Of Girth Upto 30 Cm Measured At A Height Of 1M Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area Cleared , Brick Work With Fly Ash Bricks F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Cement Plaster (In Fine Sand) 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Formation Of Dyke/ Roads Using Approved Materials Including The Preparation Of Borrow Area,Stripping, Watering Of Borrow Area, Excavation Of Approved Quality Of Material From Borrow Area,Using Poclains Or Any Other Mechanical Means,Loading, Unloading, Transporting By Dumpers,Trucks Etc., Surface Watering / Dewatering,Lowering Of Water Level To At Least 0.5 M Belowthe Bottom Of The Working Level, Includingconstruction Of Cofferdams Wherever Required,Depositing The Fill Material On The Dyke,Spreading By Dozers Or Grader In Layers Notexceeding 30 Cm In Compacted Thickness Forforming The Embankment With All Leads, Lifts,Breaking Clods, Watering, Compaction With Min. 10Tone Capacity Vibratory Rollers Or Pneumatictyred Rollers To Achieve A Dry Density Not Lessthan 95% Of Maximum Dry Density (Standardproctor) Forming Extra Width On Edges, Trimmingof Slopes And Slope Compaction With Dozers Orslope Compactors To Obtain The Section As Perconstruction Drawings, With All Incidental Charges, Cost Of Labour, Equipment, Materialsetc. Complete As Per Specifications, Drawings And As Directed By The Engineer. With Ash Available From Inside Ash Dyke Area , Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate,Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Same As Above Item But Steel Shall Be Issued By Department Free Of Cost ( Steel Issued By Department) , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bendin G, Placing In Position And Binding All Complete For Thermo-Mechanically Treated Bars
Contract Date: Ref. Documents Contract Value : 75.62 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
29.
Educational and Research Institute #11191898 Price Bid
Tender for Civil Work , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site Ne , 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.7 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) , 5.22.6 Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or Moree , 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 22.5 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 50.13.1 9 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete , 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding , 11.49.2 Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tiles 600X600 Mm , 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm , 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.20.1 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Light Shade Pigment Using White Cement , 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , 5.30 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.2.2 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) , 9.117.1 Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below (Tolerance ±1 Mm), With Wall Thickness 2.0Mm (±0.2 Mm), Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 48X40 Mm , 9.118.2 Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride (Pvc) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised/Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm (± 0.2 Mm) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic/Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece , 22.23.2 Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerin Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Horizontal Surface One Coat @1.10 Kg Per Sqm. , 13.26 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete , 13.48.1 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Two Or More Coats Applied On Walls @ 1.25 Ltr/10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr /10 Sqm , 13.48.3 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture , 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Od398633/2025-2026 Supplying And Fixing Steel Pressed Single Panelled Door Of Size 120*205Cm With Steel Frames Using Superior Quality Gi Sections Made Of Tata Steel , Od398630/2025-2026 Providing And Fixing Roller Blinds Curtains Using Good Quality Materials, Fitted To The Wall With Necessary Fittings. All Complete As Per Direction Of Engineer In-Charge , Od398632/2025-2026 Providing And Fixing Of Acrylic Name Board With Printed Acrylic Board .All Work As Per The Direction Of Engineer In Charge , Od398631/2025-2026 Supply And Fixing Of Name Board Of Size 3.60*0.60M Made Of Acp Panels Supported Over Gi Frame Work , Furnishing Work , Od398627/2025-2026 Providing And Fixing Staff Table Of Size 2.00X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete.. , Od398625/2025-2026 Providing And Fixing Staff Table Of Size 1.80X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete. , Od398626/2025-2026 Providing And Supplying Staff Revolving Chair , Od398629/2025-2026 Supplying High Back Executive Chair Nylon Base Multi-Function Mechanism, With Cushion And Leather Finish, Including Transporting Charges And All Other Loading And Handling Charges. , Od398628/2025-2026 Supplying Of Public / Waiting Seating: Three Seater. ( 35 Kg - Gw ) Gauge : 14 &Rdquo;, Dimension: 173Cm * 64Cm * 89Cm. Seat Dimension : 43Cm * 51Cm * 49Cm. Seat &Amp; Back: 1.5Mm Perforated Powder Coated. Beam: 2.0Mm Mild Steel Powder Coated , Od398624/2025-2026 Supply Of Godrej Steel Shelf Of Size 1.00 X 0.50 X2.10M, 16 Gauge , Made Of Good Quality Sheet Applying Suitable Paints All Complete As Per The Direction Of Engineer-In Charge , Plumbing And Sanitary Fittings , 17.3.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.7.8 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 , 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend. , 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee , 50.18.9.13.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 12 Kgf/ Cm2- External Work- Exposed On Wall Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mml Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.17.1 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall , 50.18.9.20.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 63 Mm Dia Bendl , 50.18.9.20.5 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement - 63X63x63 Mm Dia Tee , 18.54.4 Providing And Fixing Ptmt Bib Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 90 Mm Long, Weighing Not Less Than 93 Gms , Electrical Works , 90.1.1.1 Supply And Laying Medium Gauge Pvc Conduit Of The Following Sizes Conforming To Is 9537/1983 Part Iii In Roof Slab, Jointing The Pipes With Pvc Solvent Cement, Tying & Fixing The Conduit Firmly With The Re-Inforcement Etc. As Required.20 Mm , 90.2.2.1 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 1.10.2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mmfrls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B , 90.2.2.3 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point Without Ceiling Rose - Short Point , 90.2.2.4 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.2.5 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Call Bell Point With 6 A Bell Push At One End And 6 A, 3 Plate Ceiling Rose At Other End - Short Point , 90.2.2.6 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points , 90.2.2.7 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Independent Plug - Short Points , 90.3.18.2 Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.32 Mm Dia With Hg Company Fabricated Clamps , 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , 90.5.1.3 Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650/1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.10.3.15 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )32A Dp Switch With Indicator) , 90.10.3.14 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A Sp Switch With Indicator , 90.10.3.32 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3 Pin Plug Top With Indicator , 90.10.3.33 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3Pin Shuttered Socket , 90.15.4.2 Supply Conveyance, Installation, Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.16.1.3 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.1.1 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.5.3 Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 2.3.1 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 6 Way, Double Door , 2.3.4 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door , 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , 2.10.3 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole , 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Commissioning Etc. As Required. 40 Amps Amps , 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And , 1.17.2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 1.5 Sq. Mm , 1.17.4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 1.5 Sq. Mm , 1.17.11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 2.5 Sq. Mm , 1.17.13 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 2.5 Sq. Mm , 1.17.20 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 4 Sq. Mm , 1.17.29 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 6 Sq. Mm , 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 annual periodical maintenance Switch , 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 annual periodical maintenance Socket Outlet , 1.26 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.56 Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5/6 A Modular Socket Outlets And 2 Nos. 5/6 A Modular Switches, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , 1.58 Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Od398610/2025-2026 Supply ,Installation Of 32 A Kit Cat Fuse Unit Made By Porcelain/ Ceramic , Od398618/2025-2026 Providing And Fixing Of Service Pipe (32 Mm) , Od398612/2025-2026 Supply And Fixing 200Mm Plastic Shade On Existing Batten/Angle/Pendant/Bracket Fittings As Required , Od398615/2025-2026 Supply And Fixing 9 W Led Bulb On Existing Lamp Holder B22 , Od398613/2025-2026 Supply And Providing Suitable Iron Hook Grouted On The Ceiling For Hooking The Ceiling Fan , Od398622/2025-2026 Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss. -200 Mm, Single Phase Light Duty Exhaust Fan In Plastic Frame ( Light Duty Exhaust Fan) , Od398616/2025-2026 Fabrication, Supply And Installation Of Wall Mounting Powder Coated Open Type Gi Meter Box Of Following Size Suitable For Fixing Single Phase Energy Meter, Kit Cat Fuse, Neutral Link Etc. Hinged Door Construction, Knock Out For Cable Entry Etc. As Required , 90.6.6.2 Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.2.50 Sq Mm , Od398614/2025-2026 Supply Installation Testing And Commissioning Of Single Phase Dol Starters For 0.25 To 3 Hp Motor , Od398617/2025-2026 Supply Installation Testing And Commissioning Of Water Purifier Wit The Following Specifications (12 L Ro + Uv + Tds + Controller) , Od398619/2025-2026 Supply Installation Testing And Commissioning Of Iso / Bis Certified Igbt Technology Based 2.5Kv Online Ups/Inverter With Minimum 3 Years On-Site Waaranty And Having The Following Minimum Specifications. 1. Output:230V+1% 50Hz Sine Wave Single Phase. 2. Input: 170V To 270V Hz Ac 3. Rating: 2.5Kva, 4. Backup Time: Minimum 2 Hrs, On Full Load, 5. Efficiency: 90% Or Higher. 6. Battery Bank: 150Vah/Above(2Nos) Or Higher Tubular Battery With Minimum 3 Years Warranty With Suitable Battery Rack. 7. Protection: Over Load, Short Circuit, Battery Reverse Polarity, Input Voltage Below Or Above The Specified Range Over Discharge Or Charge Of Battery, Accepted Model: Hykon Or Equivalent Brand With Better Specification. , Od398620/2025-2026 Supply, Conveyance, Installation And Testing Of 80Cm(32 Inch) Hd Ready Led Tv Of The Following Sizesusing Standard Accessories Including And Providing Wall Mounting Stands. Screen Resolution 1366X768- Hd And 2 Hdmi &Amp; 1 Usb Ports, Working On 230V/240V Single Phase A/C As Required , Od398611/2025-2026 Supply And Installation Of Set Top Box , Od398623/2025-2026 Earthing With G.I. Earth Pipe 2.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But With Charcoal/ Coke And Salt) As Required , Od398621/2025-2026 Supply &Amp; Installation Of 1200Mm, 20W Led Tube And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire . , Network Wiring And Installation , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 1.27.1 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.53.1 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Od398643/2025-2026 Providing And Fixing Of 16-Port Gigabit Unmanaged Switch.( D-Link Dgs-1016A Or Equivalent ) , Od398639/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398644/2025-2026 Supply Installation Testing And Commissioning Of Following Sizes Of Wall Mount Network Rack. 4U 350D( But Without Server, Switches Cooling Fans Etc.) , Od398636/2025-2026 Supply Installation Testing And Commissioning Of Cat6 Utp 24-Port Network Panel Desktop 19-Inch Rack Integration Server Mounting Shielded.24 Port Laded Patch Panel (D-Link Or Equivalent) As Required. , Od398634/2025-2026 Supply Installation Testing And Commissioning Of Wireless Ac1200, Dual-Band And Ceiling Mount Gigabit Access Point (Tp-Link Eap225 Ac1200 Wireless Mu-Mimo Gigabit Indoor/Outdoor Access Point/ Equivalent) , Od398637/2025-2026 Supply And Stackingg Of Cat-6 Patch Cord -2M , Od398640/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable-1Mtr , Od398642/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable- 0.5 Mtr , Od398641/2025-2026 Supply, Conveyance, Installation And Testing Of Cooling Fan For Incubator, Fan For Computer Server 120 * 120 * 38Mm, 4.7 Inch Black , Od398638/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398635/2025-2026 Supply Conveyance And Installation Of Poe Injector. (Tenda Te-Poe30g-At Gigabit Poe Injector Or Equivalent) N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
30.
Home Affairs #11189992 AOC
Bids Are Invited For Augmentation Of Building- 1 Supplying And Placing In Position Main Table,Eru & Pedestal Of The Following Specifications. The Main Table Shall Be Of Size 3600 Width Mm X 1080 Mm Depth X 750 Mm Height. Top Surface Of The Table Shall Made Up Of Mdf (Medium Density Fibre ) Board Duly Finished With Veneer And Final Coating Of Pu. The Main Desk Should Contain In Smart Case - Space Slides Effortlessly In Style.The Mobile Pedestal Shall Be Of Size 480 Width Mm X 640 Depth Mm X 600 Height Mm. Mobile Pedestal Shall Be Coated Of Mdf (Medium Density Fiber) With Veneer Coating And Pu Coating.The Eru Top Shall Be Of Mdf (Medium Density Fiber) Board Duly Finished With Veneer And Final Pu Coating. Size Of Eru Top 1900 Width Mm X 480 Depth Mm X 550(Not From Ground With Castors).The Main Desk Is Provided Eith The Wire Management System Also There Is Perfect Storage Side Unit . 1 2 Supplying And Placing In Position Back Unit Of The Following Specifications. The Size Of The Back Unit Shall Be 1000 Mm Width X 480 Mm Depth X 2035 Mm Height. The Back Unit Shall Be Made Up Of Mdf Board Duly Finished With Veneer & Final Finish By Pu Coating. The Mobile Unit Can Be Bought In Multiples.Pu Coating Hardness 1.5H. 2 3 Providing, Supplying And Placing Of 3 Seater Sofa. Dimensions W X H X D (Cm)222 X 103 X 89 .Nomenclature & Dimensions (Mm): Tolarence + / - 10 Mm Code Description Specification Code Description Specification A Total Width 2220 B Total Depth 890 C Total Height 1030 D Seating Area Width 1720 E Seating Area Depth 520 F Seating Area Height From Ground 510 G Arm Height 645 H Arm Width 250 I Back Height From Arm 420 J Back Width 2060 K Arm Depth 610 L Leg Height 70 M Back Height From Seat 660 N Lumbar Height From Seat 410 Stitching: Thread : Polyester Pitch :- 4 ( Type Of Thread : Nylon , Polyester) ( Pitch Of Thread I.E. Stitch Per Inch) No. Of Ply In Thread : 3 Stitching Tolarence : 10 Mm Minimum Tex # (Tkt #): 75 Tkt Leather/Pvc/Fabric: (Pu/Pvc/Cotton/ Polyester/ Composite) Pigmented Leather + Pvc Thickness (Mm) :Leather=1.5Mm / Pvc=0.38Mm Weight (Gsm) : Pvc=750Gsm Tensile Strength {Wrap/Weft} (Kg/Cm) : Leather=300Kg/Cm2 + Pvc=100Kg/Cm2 Bursting Strength (Kg/Cm2) : Adhesion (Pvc/Pu Backing) (Kg/Cm) : Colour Fastness To Rubbing {Dry /Wet} (Scale 1-5) : Leather=5 / Pvc=3 Frame Material (Tropical Wood / Pine Wood/ Rubber Wood): Pine Wood Moisture Content ( Recommended 12 – 18 %) :15% Anti – Tremite Treatment (Recommended Borex Powder Treatment) : Kiln Drying : Conventional Thickness Of Plywood Used(Mm) : 3Mm/9Mm/12Mm/18Mm Standard Of Plywood Used: Commercial Plywood Seat Foam: (Density, Type) * Provide Weight Of Recron Filling Used Per Seat* Thickness (Mm) : 127Mm Density (Kg/M3): 27 Kg/M3 + 30 Kg/M3 Type Of Foam (Virgin/Composite/Moulded/ Slabstock) : Virgin * Please Provide Layerwsie Detail Of Foam Used Along With Details Of Density & Thickness* Back Foam: (Density, Type) * Provide Weight Of Recron Filling Used Per Seat* Thickness (Mm) : Recron Filling 1.0Kg /Seat Density (Kg/M3): N/A Type Of Foam (Virgin/Composite/Moulded/ Slabstock) : N/A * Please Provide Layerwsie Detail Of Foam Used Along With Details Of Density & Thickness* Armrest Foam: (Density, Type) * Provide Weight Of Recron Filling Used Per Seat* Thickness (Mm) : 38Mm Density (Kg/M3): 27 Kg/M3 + 30 Kg/M3 Type Of Foam (Virgin/Composite/Moulded/ Slabstock) : Virgin * Please Provide Layerwsie Detail Of Foam Used Along With Details Of Density & Thickness* Belt/ Webbing Material: Width Of Belt (Mm) : N/A. Total Length Of Belt Used (Mm): N/A. Tensile Strength (Kg/Cm) : N/A. Recommended 3-4 Vertical & 3 Horizontal Webbing Mesh & 50 % Stretch While Fixing Spring Details ( S-Spring / Pocket Spring): Thickness Of S-Spring (Mm) : 4.0Mm & 34Mm Width Number Of Springs Used: [4 S-Springs (Zig-Zag Springs) + 1 Tie Rods]/ Seat Length Of S-Spring Used (Mm) : N/A. Number Of Pocket Springs Per Seat: N/A. Thickness Of Pocket Spring (Mm) : N/A. * Provide Details Of Number Of Pocket Springs & Pitch * Leg Material: * Fixing Of Leg : (Self Tapping Screw / Insert With Metric Threading) :- N/A * Material Of Leg : (Plastic / Insert Moulding / Wooden/ Ms + Chrome Plating / Ss) :- N/A * Bush For Leg Bottom : (Pvc Bush / Felt Pad) :- N/A Bonding Solution: * Type Of Glue Used : (Synthetic / Rubber Base/ Water Base/ Solvent Base) : Rubber Base Glue * Material Handling Data Sheet (Msds) For Glue Polyester Fibre Fill : * Denier : 13 * Fiber Hollowness : 100% * Siliconized Fibre * Conjugated Fibre Stapling Pins: * Size Of Pin : (Zinc Plated) Yes * No. Of Pins : Bottom Non-Woven Cloth : * Gsm : 100 Gsm Non Woven Cloth * Colour : Black Colour Metal Under Structure Detail : * Bedstead Size : (In Mm) * Pipe / Tube Section : ( L X B X Thickness) * Mesh Size : ( Thickness & Mesh Square Size) Plating/ Coating : Type Of Plating : Powder Coating Salt Spray Test : (In Hours) Recommended 96 Hrs Of Salt Spray For Plating & 250 Hrs For Coating Mechanism : Manual / Automatic : Manual Mechanism Make : Allstar Warranty Of Mechanism : (Recommended 3 Years Warranty On Mechanism) Actuator Power Rating : Packing Specs: Carton Ply Gsm :- Number Of Ply : Bursting Strength (Kg/M2) : Recommended 22 – 24 Bs 5 Ply Gsm Of Paper : 200-180-180- 180-180 Other Remarks: As Per Specification Or Picture Warranty : 2 Years Warranty For Sofa Upholstery 3 Years Warranty For Recliner Mechanism 4 Providing, Supplying And Placing Of 1 Seater Sofa. 5 Providing, Supplying And Placing Of Coffee Table Overall Size : Width: 100Cm Depth : 65Cm Height : 43Cm 6 Providing, Supplying And Placing Of High Back Chair. Seat Assembly: The Cushioned Seat Inner Is Made Of Injection Moulded Glass Filled Polyamide.Upholstered Seat Sub-Assembly Consists Of Moulded High Resilience (Hr) Polyurethane Foam Of Density 45±2 Kg/M³, And Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression 7 Providing, Supplying And Placing Of Visitor Chair. Chair 8 Supplying And Placing In Position Conference Table Of The Following 9 Providing, Supplying And Placing Of High Back Chair. Seat/Back 10 Providing, Placing And Supplying Of Table 11 Providing, Placing And Supplying Of Wood Chair. 12 Supplying And Placing In Position Main Table,Eru & Pedestal 13 Supplying And Placing In Position Back Unit Total Quantity : 5
Contract Date: Ref. Documents Contract Value : 3.98 Crore
Government Departments No of Bidders 3
Andhra pradesh View Result →
31.
Health and Family Welfare #11180771 Price Bid
Tender For Supply Of Drugs And Medicines- 1 Drugs And Consumables 2 Oxygen (Medicinal Gas) Inhalation 3 Oxygen(Medicinal Gas) Inhalation Should Be Certified For Medical Use Contains Not Less Than 99% V/V Of Oxygen, Contains Not More Than 5Ppm V/V Of Carbanmonooxide, Contains Not More Then 30Ppm V/V Of Carban Dioxide Should Be Free Of Halogens, Oxidising Substances & Water. 4 Halothane Inhalation 250 Ml Bottle 5 Ketamine (As Hydrochloride) Injection 50 Mg /Ml,10 Ml Vial 6 Nitrous Oxide Inhalation 7 Thiopentone Injection Powder 0.5 G 8 Propofol Injection 1% Vial (10 Mg/Ml , 10 Ml Vial) 9 Isoflurane Inhalation 100 Ml Vial 10 Sevoflurane Inhalation 250 Ml 11 Bupivacaine Injection 0.5%, 5Ml Amp. 12 Bupivaccine Heavy 5 Mg With Dextrose Monohydrate 80 Mg/Ml Injection 4 Ml Ampoule 13 Lignocaine Injection 2%, 30 Ml Vial 14 Lignocaine Jelly 2% W/V ( With Seprate Nosal), 30Gm Tube 15 Lignocaine Hydrochloride And Adrenaline Bitartarate Injection 20Mg/Ml And 0.01Mg/Ml Adrenaline, 30 Ml Vial 16 Atropine Injection 0.6 Mg/Ml, 1 Ml Ampoule 17 Glycopyrolate Injection 0.2 Mg/Ml, 1 Ml Ampoule 18 Diazepam Injection 5 Mg/Ml, 2 Ml Ampoule 19 Diazepam Tablet 5 Mg 20 Midazolam Injection 1 Mg/Ml, 5 Ml Vial 21 Midazolam Nasal Spray 1.25 Mg/Spray 22 Diclofenac Supositories 50 Mg 23 Diclofenac Sodium Gastro-Resistant Tablet 50 Mg 24 Diclofenac (Sodium) Injection 25 Mg/Ml ,3Ml Amp. 25 Diclofenac Gel 1%, 30 Gm Tube 26 Diclofenac + Paracetamol Tablet 50Mg+325Mg 27 Ibuprofen Tablet 200Mg 28 Ibuprofen Tablet 400 Mg 29 Ibuprofen Suspension 100 Mg/5 Ml. 60 Ml Bottle 30 Paracetamol Tablet 500 Mg 31 Paracetamol Injection 150 Mg/Ml, 2 Ml Amp. 32 Paracetamol Peaditric 125Mg/5Ml 60 Ml Bottle 33 Paracetamol Paediatric Oral Suspension 150Mg/Ml, 10 Ml Vial With Marked Dropper 34 Paracetamol Infusion 100 Mg/10 Ml, 100 Ml Bottle Ffs Technology - 35 Aceclofenac Tablet 100 Mg 36 Etoricoxilb Tablet 90 Mg 37 Morphine Injection 10 Mg/Ml, 1 Ml Ampoule 38 Morphine Tablet 20 Mg 39 Tramadol Capsule 50 Mg 40 Tramadol Injection 50 Mg/Ml, 2 Ml Ampoule 41 Tramadol Hydrochloride Capsule 100 Mg 42 Pentazocine Injection 30 Mg/ Ml, 1 Ml Ampoule 43 Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule 44 Pethidine Injection 50 Mg/Ml, 1Ml Ampoule 45 Thiocolchicoside Capsule 4 Mg 46 Midazolam Nasal Spray 1.25 Mg/Spray 47 Beclofen Tablet 10 Mg Tablet 48 Allopurinol Tablet 100 Mg 49 Sulfasalazine Tablet 500 Mg 50 Methotrexate Tablet 2.5 Mg 51 Methotrexate Tablet 5 Mg 52 Naxproxen (500Mg)+ Domperidone (10Mg) Tablet 53 Diacerein 50 Mg + Glucosamine Sulphate 750 Mg Tablet - 54 Cetrizine Syrup 5 Mg/5Ml, 60 Ml 55 Chlorpheniramine Tablet 4 Mg 56 Pheniramine Maleate Injection 22.75 Mg/Ml, 2 Ml 57 Hydroxyzine Tablet 10 Mg 58 Dexamethasone Tablet 0.5 Mg 59 Dexamethasone Injection 4Mg/Ml, 2 Ml Ampoule 60 Hydrocortisone ( Sodium Sucinate Powder) Injection 100 Mg Vial, With 2 Ml Distilled Water For Reconstitution 61 Prednisolone Tablet 10 Mg 62 Prednisolone Tablet 20 Mg 63 Methyl Prednisolone Injection 1Gm, 1 Gm Vial With Diluent 64 Adrenaline Injection 1 Mg/Ml, 1:1000, 1 Ml Amp 65 Levocetrizine Tablet 5 Mg 66 Nor Adernaline Injection 4Mg/Ml 67 Cyproheptadine Tablet 4 Mg 68 Monteleukast Tablet 5 Mg 69 Methyl Prednisolone Tablet 8 Mg 70 Antisnake Venom ( Dry Powder For Polyvalent Solution) Injection Vial With 10 Ml Diluent 71 Calcium Gluconate Injection 100 Mg/Ml, 10 Ml Amp 72 Naloxone Injection 400 Mcg/Ml, 1Ml Ampoule 73 Pralidoxime (Pam) Injection 1 Gm Vial 74 Activated Charcoal Tablet 500 Mg 75 Carbamazepine Tablet 200 Mg 76 Carbamazepine Tablet 400 Mg 77 Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle 78 Lorazepam Tablet 1 Mg 79 Lorazepam Tablet 2 Mg 80 Lorazepam Injection 4Mg, 2Ml 81 Magnesium Sulphate Injection 1 Gm /2Ml (50%W/V), 2 Ml Ampoule 82 Magnesium Sulphate Injection 2.5 Gm /5Ml(50%W/V), 5 Ml Ampoule 83 Phenobarbitone Tablet 30 Mg 84 Phenobarbitone Tablet 60 Mg 85 Phenobarbitone Injection 200 Mg/ Ml 86 Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle 87 Phenytoin Tablet 100 Mg 88 Phenytoin Tablet 300 Mg 89 Phenytoin Oral Solution 25 Mg/Ml, 100 Ml Glass Bottle 90 Phenytoin (Sodium) Injection 100Mg, 2Ml Amp. 91 Sodium Valproate/Valproic Acid Enteric Coated Tablet 200 Mg 92 Sodium Valproate/Valproic Acid Enteric Coated Tablet 500 Mg 93 Sodium Valproate/Valproic Acid (Sodium)Controlled Released Tablet 300 Mg 94 Sodium Valproate Injection 100 Mg/Ml 95 Sodium Valproate Suspension 200 Mg/5 Ml, 100 Ml 96 Clobazam Capsule 10 Mg 97 Divalproex Sodium Tablet 500 Mg 98 Levetiracetam Tablet 500 Mg 99 Toperamate Tablet 50 Mg 100 Injection Levetricatum 100 Mg, 3 Ml - 101 Levitiracetam Oral Solution 102 Levitiracetam Oral Solution, 100Mg/Ml, 100Ml Bottle 103 Albendazole Chewable Tablet 400 Mg 104 Albendazole Oral Suspension 200 Mg/5 Ml,10 Ml Bottle 105 Levamasole Tablet 50 Mg 106 Levamasole Tablet 150 Mg 107 Amoxicillin Capsule 250 Mg 108 Amoxicillin Capsule 500 Mg 109 Amoxicillin Oral Suspension 125 Mg/5 Ml, 60 Ml Bottle 110 Amoxicillin + Pottasium Clavulanate Tablet 500 Mg + 125 Mg 111 Amoxicillin + Pottasium Clavulanate Dispersible Tablet 200 Mg +28.5 Mg 112 Amoxicillin + Clavulanic Acid Injection 1.2 Gm , 10 Ml Vial With Diluents 113 Amoxicillin + Clavulanic Acid Injection 250 Mg +50 Mg, Vial With Diluents 114 Ampicillin Sodium Injection 500Mg 2 Ml Vial With Diluent 115 Cefixime Tablet 200 Mg 116 Cefixime Oral Suspension 50 Mg/ 5 Ml, 30 Ml Bottle 117 Cefadroxil Oral Suspension 125 Mg/ 5Ml, 30 Ml Bottle 118 Cefotaxime Injection 250 Mg 119 Cefotaxime Injection 500 Mg 5 Ml Vial With Diluent 120 Cefotaxime Sodium Injection 1 Gm 10 Ml Vial With Diluent 121 Ceftriaxone Injection 250 Mg 2 Ml Vial With Diluent 122 Ceftriaxone Injection 1 G, 10 Ml Vial With Diluents 123 Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent 124 Cefoperazone + Sulbactam (1G+1G) Injection 125 Immipenum Injection 500 Mg 126 Imipenem And Cilastatin Injection (500 Mg+500 Mg) 127 Cefazolin Injection 1 Gm 128 Amikacin Injection 250Mg/ Ml, 2 Ml Vial 129 Amikacin Injection 50 Mg/ Ml, 2 Ml Vial 130 Gentamycin Injection 40 Mg/ Ml, 2 Ml Ampoule 131 Azithromycin Tablet 250 Mg 132 Azithromycin Tablet 500 Mg 133 Azithromycin Oral Suspension 40 Mg/Ml , 15 Ml Bottle 134 Levofloxacin Tablet 500 Mg 135 Ofloxacin Tablet 200 Mg 136 Ciprofloxacin Tablet 250 Mg 137 Ciprofloxacin Tablet 500 Mg 138 Ciprofloxacin Injection 2Mg/Ml, 100 Ml Bottle For Infusion Ffs Technology 139 Doxycycline Capsules 100 Mg 140 Cotrimoxazole (Sulfamethoxazole + Trimethoprim) Tablet 800 Mg + 160 Mg 141 Co-Trimoxazole [Sulphamethoxazole (A) + Trimethoprim (B)] Oral Liquid 200 Mg (A) + 40 Mg (B)/5 Ml 142 Metronidazole Tablet 200 Mg 143 Metronidazole Tablet 400 Mg 144 Metronidazole I.V Infusion 5 Mg/Ml, 100 Ml Bottle For Infusion (Ffs Technology) 145 Metronidazole Suspension 200Mg/5Ml , 60 Ml Bottle 146 Cloxacillin Capsule 500 Mg 147 Nitrofurantoin Capsule 100 Mg 148 Vancomycin Injection 500 Mg 149 Linezolid Tablet 600 Mg 150 Norfloxacin Tablet 400 Mg 151 Fluconazole Tablet 150Mg 10*10 152 Fluconazole Tablet 200 Mg 10*10 153 Griseofulvin Tablet 250 Mg 154 Itraconazole Capsules 200 Mg 155 Amphotericin B Powder For Injection 50 Mg And Vial Has Sodium Deoxychlolate Or Liposomal Complex 156 Terbinafine Tablet 250 Mg 157 Acyclovir Tablet 200 Mg 158 Acyclovir Tablet 400 Mg 159 Acyclovir Tablet 800 Mg 160 Tinidazole Tablet 500 Mg 161 Ivermectin Tablet 6 Mg 162 Diethyl Carbamazine Tablet 100Mg 163 Flunarazine Tablet 10 Mg 164 Propranolol Tablet (Sr) 40 Mg 165 Propranol Tablet 20 Mg 166 Levodopa + Carbidopa Tablet 100 Mg + 10 Mg 167 Trihexyphenidyl Tablet 2 Mg 168 Bromocriptine Tablet 2.5 Mg 169 Ferrous Sulpahte + Folic Acid Syrup 100 Mg + 0.5 Mg/ 5 Ml In A Flavoured Base/Vehicle 50 Ml Bottle, Ropp Cap Bottle With Inert Liner & Bottle To Be Provided With A Dispenser To Dispense To 1 Ml, 1.5Ml And 2 Ml Each Time And Packed In A Mono Carton Note:- For Detailed Specifications Kindly See Below Attached Copy. 170 Elemental Iron 60 Mg +Folic Acid 500 Mcg, Sugar Coated And Red Color Tablet 171 Ferrous (Iron Sucrose) Injection 20 Mg/Ml 172 Folic Acid Tablet 5Mg 173 Hydroxycobalamin Injection 1 Mg/ Ml 174 Warfarin (Sodium) Tablet 2 Mg 175 Heparin Injection 1% 176 Enoxaprin Sodium Injection 60 Mg In Pfs 177 Phytomenadion Injection 1 Mg/0.5 Ml Water Based Single Dose Ampoule 178 Plasma Volume Expander Injection ( Each 100 Ml Contains Polygeline, Polypeptides Of Degaraded Gelatin, Cross Linked Via Urea Bridges 3.5 G ( Equivalent To 0.63 G Of Nitrogen) Nacl Ip 0.85 G, Kcl Ip 0.038 G Cacl2 Ip 0.070G Water For Injection Ip Q.S Electrolytes In M.Mol/Litre, 500 Ml Ffs 179 Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms 180 Glyceryl Trinitrate ( Niroglycerine) Injection 5 Mg/Ml, 5 Ml Ampule 181 Isosorbide Mononitrate Tablet 30 Mg (Sr) 182 Isosorbide Dinitrate Tablet (Sublingual) 5 Mg 183 Metoprolol Tablet 25 Mg 184 Metoprolol Tablet (Sr) 50 Mg 185 Carvediolol Tablet 3.125 Mg 186 Adenosine Injection 3 Mg/ Ml, 1 Ml Ampoule 187 Diltiazem Injection 5 Mg/Ml 188 Diltizem Hydrochloride Tablet 30 Mg (Modified Release), 10*10 189 Amiodarone Tablet 100 Mg 190 Verapamil Tablet 40 Mg 191 Amiodarone Injection 150 Mg/ 3 Ml 192 Atenolol Tablet 50 Mg 193 Amlodipine Tablet 5 Mg 194 Amlodipine Tablet 10 Mg 195 Methyldopa Tablet 250 Mg 196 Methyldopa Tablet 500 Mg 197 Nifedipine Capsule(Sublingual) 5 Mg 198 Nifedipine Tablet Ip Sr/Er 10 Mg 199 Ramipril Tablet 5 Mg 200 Labetalol Tablet 100 Mg 201 Labetolol Injection 5Mg/Ml, 4Ml Amp. 202 Telmisartan Tablet 40 Mg 203 Telmisartan Tablet 80 Mg 204 Losartan + Hydrochlorothiazide Tablet (50 Mg + 12.5 Mg) 205 Olmesartan 20 Mg + Amlodipine 5 Mg + Hydrochlorothiazide 12.5 Tablet 206 Clinidipine Tablet 20 Mg 207 Hydrochlorthiazide Tablet 12.5 Mg 208 Chlorthalidone Tablet 6.25 Mg 209 Nebivalol Tablet 5 Mg 210 Enalapril Tablet 5 Mg 211 Dobutamine Injection 250Mg/5Ml 212 Dopamine Injection 40 Mg/ Ml In 5Ml Ampoule 213 Digoxin Tablet 0.25 Mg 214 Acetylsalicylic Acid Tablet 150 Mg 215 Acetylsalicylic Acid Tablet 75 Mg Gastro-Resistant (Enteric Coated/ Delayed Release) 216 Clopidogrel Tablet 75 Mg 217 Streptokinase Injection Powder 1500000 Iu 218 Atorvastatin Tablet 10 Mg 219 Atorvastatin Tablet 20 Mg 220 Rosuvastatin 10 Mg+ Fenofibrates 160 Mg Tablet 221 Tranexamic Acid Tablet 500 Mg 222 Tranexamic Acid Injection In Water For Injection 100 Mg/Ml, 5 Ml Ampoule 223 Mephentermine Injection 30 Mg/Ml, 1 Ml Amp. 224 Tranexamic Acid 500 Mg + Mefenamic Acid 250 Mg Tablet 225 Citicoline Tablet 500 Mg 226 Clotrimazole Pessaries 200 Mg 227 Clotrimazole Cream 2% W/W, 15 Gm 228 Clotrimazole Mouth Paint 1% W/V In Propylene Glycone Glycerian Base 15 Ml 229 Sertaconazole Cream 2% W/W, 15 Gm 230 Ketaconazole Lotion 2% W/V, 50 Ml 231 Acyclovir Eye Ointment 3% , 4.5 Gm Tube 232 Clindamycin Gel 1% W/W, 10Gm Tube 233 Clobetasol 0.05% + Gentamycin 0.1% Ointment 15 Gm Tube 234 Silver Sulfadiazine Cream 1%, 30 Gm Tube 235 Framycetin Cream 1%, 30 Gm Tube 236 Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle 237 Benzoyl Per Oxide Gel 2.5%, 20 Gm Tube 238 Permethrin Lotion 5%, 50 Ml 239 Permethrin Cream 5%, 30 Gm 240 Betamethasone Dipropionate Cream 0.1% W/W , 5 Gm 241 Fluticasone Cream 0.01 % 10Gm 242 Calamine Lotion Ip-Calamine Ip-15% W/V, Zinc Oxide Ip-5%W/V,Glycerin Ip-5% W/V ,65Ml Bottle 243 Benzyl Benzoate 25% Lotion 100 Ml 244 Podophylline Resin Topical Solution 25% , 10 Ml Bottle 245 Fusidic Acid Cream 2%, 10Gm Tube 246 Coal Tar Solution 5% W/V, 100 Ml Bottle 247 Salicylic Acid Ointment 6%, 15 Gm Tube 248 White Petrolatum Jelly 100 %, 50 Gm Jar 249 Clotriamazole 1%+ Beclomethasone Dipropionate 0.025% Lotion 15 Ml 250 Mometasone Furoate Cream 0.1 % W/W 251 Mometasone Furoate Cream 0.1 % W/W, 10Gm Tube 252 Hydroquinone 2.0% W/W + Tretinoin 0.025% W/W + Mometasone Furoate 0.1% W/W In A Cream Base Q.S 253 Kojic Acid Cream 2 % 254 Hydroquinone 2%/4% + Tretinoin 0.025 % +Fluocinolone Skin Cream 255 Hydroquinone 4%+ Tretinoin 0.05% +Fluocinolone 0.01 % Skin Cream, 15Gm 256 Tacrolimus Ointment 0.03% W/W, 10 Gm 257 Tacrolimus Ointment 0.1% 10Gm Tube 258 Choline Salicylate Solution Bp Equivalent To Choline Salicylate 8.7 % W/W, Benzalkonium Chloride Solution Ip 0.01 % W/W, Lignocaine Hydrochloride Ip 2.0 % W/W Gel Base Q.S., 10 Ml Packing 259 Sunscreen Lotion Spf 26 ,100Ml Bottle 260 Clobetasone Butyrate(0.05 W/W + Miconazole(2.0 W/W) ,15 Gm Cream - 261 Halobetasol Propionate(0.5% W/W + Salicylic Acid (3% W/W) , 10Gm Ointment 262 Minoxidil Solution 5%, 60Ml Bottle 263 Gamma Benzene Hexachloride 1% Lotion,100 Ml 264 Sertaconazole Nitrate 2 % W/W+ Beclomethasone Dipropionate 0.025% W/W, 15Gm Tube 265 Cotrimazole 1%+ Beclomethasone Dipropionate 0.0025% Lotion 15 Ml Lotion 1%, 0.0025%, 15Ml 266 Mupirocin Cream 2% W/W,5Gm Tube 267 Isotretinoin Capsule 20 Mg 268 Methoxsalen Tablet 10 Mg 269 Triamcinolone Injection 20 Mg/ Ml 270 Triamcinolone Injection 40 Mg/Ml 271 Povidone Iodine Solution 5% ,500 Ml 272 Povidone Iodine Ointment 5%,15 Gm 273 Povidone Iodine Scrub (Povidone Iodine Cleansing Solution 7.5 %, W/V With Foaming Agent) 500 Ml 274 Povidine Iodine Scrub 7.5% W/V, 500Ml 275 Hydrogen Peroxide Solution 6%, 400 Ml Bottle 276 Cetrimide Solution 20% Conc. For Dilution, 500 Ml Plastic Bottle 277 Chlorhexidine Solution 5% Conc. For Dilution, 500 Ml 278 Bleaching Powder Containg Not Less Then 30% W/W Of Avialble Chlorine, 1Kg/25 Kg 279 Feracrylum 1% W/W Sterile Solution 100Ml Bottle 280 Feracrylum 3% W/W Gel , 15Gm Tube 281 Tritium Vulgare Extract And Phenoxyethanol Cream,32Gm Tube 282 Glutraldehyde Solution 2% - 2.5%, 1 Litre Pack 283 Potassium Permanganate Crystal For Solution 100 Gm 284 Bleaching Powder Containg Not Less Then 30% W/W Of Available Chlorine Powder - 285 Furosemide Tablet 40 Mg 286 Furosemide Injection 10 Mg/Ml, 2Ml Ampoule 287 Mannitol Intravenous Infusion 20% W/V, 100Ml Ffs Technology 288 Spironolactone Tablet 25 Mg 289 Torasemide Tablet 10 Mg 290 Tamsulosin 0.4 Mg + Dutasteride 0.5 Mg Tablet 291 Disodium Hydrogen Citrate Oral Solution/Syrup 1.38 -1.45 Gm/ 5 Ml, 100 Ml Bottle 292 Sodium Bicarbonate Infusion 7.5% W/V, 10 Ml Ampoule 293 Alkalizer Mb6 500Ml (Potassium Citrate Magnisum Citrate Syrup & Vit B6) 294 Bethanecholchloride Tablet 25 Mg 295 Darifenacin Tablet 7.5 Mg 296 Silodosin Tablet/Capsule 8.0 Mg 297 Mirabegron Tablet 50 Mg 298 Pyridium Tablet 200 Mg 299 Aluminium Hydroxide 240 Mg + Magnesium Hydroxide 100Mg+ Simethicone 25 Mg + Magnesium Carbonate 60 Mg Chewable Tablet 300 Dried Aluminium Hydroxide Gel + Magnesium Hydroxide + Simethicone Oral Suspension 250 Mg+ 250 Mg+ 50 Mg/ 5 Ml, 170 Ml Bottle 301 Ranitidine Injection 25 Mg/Ml, 2 Ml Amp 302 Ranitidine Syrup 150 Mg/10 Ml 303 Ranitidine Tablet 150 Mg, Film Coated 304 Omeprazole Capsule 20 Mg 305 Pantoprazole Injection 40 Mg, Vial With 10 Ml Diluent 306 Pantoprazole + Domperidone Sr (40Mg+30Mg) Capsule 307 Sucralfate 1Gm With Oxetacain 10Mg/10Ml Suspension 308 Simethicone Syrup 40Mg,60 Ml Bottle 309 Domperidone Tablet 10 Mg 310 Domperidone Suspension 1 Mg/Ml, 30 Ml Bottle 311 Cinnarizine Tablet 25 Mg 312 Metoclopramide Tablet 10 Mg 313 Metoclopramide Injection 5 Mg/Ml, 2 Ml Ampoule 314 Ondansetron Tablet 8 Mg 315 Ondansetron Injection 2Mg/Ml ,2Ml Ampoule 316 Ondansetron Oral Liquid 2 Mg/ 5 Ml 317 Ondansetron Oral Liquid 2Mg/5 Ml , 30 Ml Bottle 318 Promethazine Injection 25 Mg/Ml, 2 Ml Amp 319 Promethazine (Hydrochloride) Elixir Or Syrup 5 Mg/5 Ml, 60 Ml Bottle 320 Doxylamine Tablet 10 Mg 321 Prochlorperazine Mouth Dissolving Tablet Flavored Base 5Mg 322 Anti-Haemorrhoidal Containing: Beclomethasone Dipropionate 0.025% W/W, Phenylephrine Hyderochloride 0.10% W/W, Lignocaine Hydrochloride 2.5% W/W In Soft Paraffin Base 20 Gm Tube 323 Dicyclomine Tablet 10 Mg 324 Dicyclomine Oral Solution 10Mg/5Ml 325 Mephenamic Acid + Dicyclomine Tablet 500 Mg +20 Mg 326 Drotaverine Tablet 80 Mg 327 Drotaverine Injection 40 Mg/ 2 Ml 328 Hyoscine Butyl Bromide Tablet 10 Mg 329 Hyoscine Butyl Bromide Injection 20 Mg/ Ml, 1 Ml Amp. 330 Bisacodyl Gastro-Resistant (Enteric Coated/Delayed Release) Tablet 5 Mg 331 Lactulose Solution 10 Gm/ 15 Ml, 60 Ml Bottle 332 Ispaghula Granules/ Husk/ Powder 100 Gm 333 Enema 334 Dioctyl Sulfosuccinate Sodium Liquid,100 Ml 335 Magnesium Hydroxide Liquid 100 Ml 336 Oral Rehydration Salts Powder For 1000 Ml Solution 337 Oral Rehydration Salts Powder For 200 Ml Solution 338 Zinc (Sulphate) Dispersible Tablet 20 Mg 339 Octreotide Injection 100 Mcg/Ml, Single Dose 1 Ml Vial 340 Levosulpride (Sr) 75 Mg + Rabeprazole (Ec) 20 Mg Capsule 341 Saccharomyces Boulardii 5 Cfu Sachets 342 Probiotic Capsule/Syurp (Vizylac/Sporolac) 343 Probiotic Syrup (Streptococus Faecalis 30 Million, Clostridium Butirium 2 Million,Bacillius Mesentiricus 1 Million,Lactic Acid Bacillus 50 Million) Suspension In 5Ml 344 Probiotic Capsule (Lactobacillius Blends) 345 Chymotrypsin+ Trypsin (1:6 ) Tablet 100K Au 346 Cyproheptadine Hcl Ip-2Mg, Tricholine Citrate-275 Mg, Sorbitol Solution (70%)(Non Crystallising) Ip-2 Gm, 200 Ml Bottle 347 Erythropoietin Injection 4000 Units/Ml, Single Dose 1 Ml Vial 348 Insulin (Soluble) Injection 40 Iu/Ml In 10 Ml Vial 349 Intermediate-Acting Insulin (Nph) Injection 40 Iu/Ml In 10 Ml Vial 350 Biphasic Isophane Injection 40 I.U/Ml, (30/70), 10 Ml Vial 351 Lantus Insulin (Insulin Glargine 100 Units/Ml) 352 Metformin Tablet 500 Mg 353 Metformin Tablet 1 Gm 354 Metformin Tablet Sr 500Mg 355 Metformin Tablet Sr 1 Gm 356 Glimipride Tablet 1 Mg 357 Glimipride Tablet 2 Mg 358 Teneligliptin Film Coated Tablet 20 Mg 359 Voglibose 0.3 Mg + Metformin 500Mg+ Glimipride 1 Mg Tablet 360 Vildagliptin Tablet 50 Mg 361 Empagliflozin Tablet 10 Mg 362 Glibenclamide Tablet 5 Mg 363 Clomifene Citrate Tablet 50 Mg 364 Medroxyprogesterone Tablet 10 Mg 365 Norethisterone Tablet 5 Mg 366 Micronized Progesterone Tablet 200 Mg 367 Mifepristone Tablet 200 Mg 368 Mifepristone Tablet 25 Mg 369 Cabergoline Tablet 0.5 Mg 370 Dienogest Tablet 2 Mg 371 α -Hydroxyprogesterone Injection 500 Mg 372 Hcg 5000 Iu(Human Chorionic Gonadotropin) Injection 373 Conjugated Estrogen Tablet 0.625 Mg 374 Ethamsylate Tablet 500 Mg Tablet - 375 Latrazole Tablet 2.5 Mg 376 Thyroxine Tablet 50 Mcg 377 Carbimazole Tablet 5 Mg 378 Ethinyestradiol Tablet 5 Mcg 379 Estrogens Cream 0.625 Mg 380 Ethinylestradiol Tablet (0.03 Mg+ Levonorgestrel (0.15) Tablet 0.03Mg, 0.15 381 Copper Bearing Intra-Uterine Device Iucd 380 A & Iucd 375 - 382 Male Condom - 383 Non Harmonal Ormeloxifene 30Mg Tablet 384 Emergency Contraceptive Pill Levonorgestrel Tablet 1.5 Mg 385 Pregency Testing Kit - 386 Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 150 Mcg/Vial 387 Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 300Mcg/Vial 388 Injection Recombinant Anti-D Immunoglobulin 300Mcg Vial/Pfs 389 Anti Rabies Immunoglobulin Injection (Human) 150 Iu/Ml, 2Ml Vial 390 Hepatitis B Immunoglobulin Injection 1Ml. 391 Hepatitis B Immunoglobulin Injection 100 Iu, 1 Ml Vial - 392 Tetanus Toxoid Injection 0.5 Ml Ampoule 393 Rabies Vaccine Single Dose Rabies Vaccine 2.5 Iu Injection For Human Use Prepared In Chick Embryo/ Vero Cell/ Human Diploid Culture Single Dose With Diluent And Disposable Syringe With Needle 394 Decaravimab+ Miromavimab Injection (600 Iu) 3 Ml 395 Atracurium Besylate Injection 10 Mg/ Ml, 2.5 Ml Amp. 396 Succinyl Choline Injection 50Mg/Ml, 10Ml Vial 397 Neostigmine Injection 500 Mcg/ Ml, 5 Ml Ampoule 398 Vecuronium Injection 10 Mg Vial 399 Ciprofloxacin Eye Drops 0.3%, 10 Ml Plastic Bottle 400 Ciprofloxacin Opthalmic Ointment 0.3 % 5 Gm Tube 401 Tobramycin Opthalmic Solution 0.3% W/V, 5Ml 402 Natamycin Eye Drops 2%, 5 Ml 403 Acylovir Eye Oint 5%,5 Gm 404 Povidone Iodine 5% Eye Drops 405 Prednisolone Sodium Phosphate Eye Drops 1%, 5 Ml 406 Flurbiprofen Eye Drops 0.03%, 10 Ml Vial 407 Flouromethalone Eye Drops 0.1 % W/V,5 Ml Vial 408 Olopatadine 0.1% Eye Drops 5 Ml 409 Acetazolamide Tablet 250 Mg 410 Timolol Eye Drops 0.5%, 5Ml 411 Atropine Drops 1% 412 Homatropine Eye Drops 1% 413 Tropicamide + Phenylepherine Eye Drops 0.8% + 5%, 5 Ml Vial 414 Cyclopentolate Eye Drops 1% W/V 415 Sodium Carboxymethyl Cellulose Eye Drops 0.5% W/V, 10 Ml 416 Hydroxypropyl Methylcellulose Injection 2% , 3 Ml Pfs (Glass Syringe) 417 Hyaluronidase Injection 1500 Iu/Ml 418 Tryptan Blue Dye 0.06% W/V, 1 Ml Vial 419 Moxifloxacin Eye Drops 0.5% W/V ,5Ml 420 Ranibizumab Injection 10Mg/Ml 421 Travoprost 40 Mg/Ml 2.5Ml Vial Eye Drop 422 Xylometazoline Nasal Drops 0.05 %, 10 Ml 423 Xylometazoline Nasal Drops 0.1 %, 10 Ml 424 Saline Nasal Drops 0.65%, 10 Ml 425 Wax Dissolving Ear Drops (Paradichlorbenzene 2% W/V, Benzocain 2.7 % W/V, Chlorbutol 5% W/V, Turpentine Oil 15% Ear Drops ), 10 Ml 426 Clotrimazole 1% W/V + Lignocaine Hydrochloride 2% W/V Ear Drops, 5Ml Bottle 427 Clotrimazole Ear Drops 5 Ml Vial 428 Ichthoimol Glycerine Solution 10 Ml Vial 429 Ciprofloxacin(0.3%)+Dexametasone(0.1%) Ear Drops ,5Ml 430 Antibacterial & Anti Fungal Ear Drop (Beclomethasone 0.025% W/V +Chloramphenicol 5% W/V +Clotrimazole 1% W/V ,Glycerine Base), 10 Ml Ear Drops 431 Fluticasone Furoate Nasal Spray 432 Fluticasone Furoate Nasal Spray 27.5Mcg, 10Ml 433 Boro-Spirit Ear Drops,3% W/V Ear Drops 10 Ml 434 Methyl Ergometrine Tablet 125 Mcg 435 Methyl Ergometrine Injection 200 Mcg In 1 Ml Ampoule 436 Oxytocin Injection 5 Iu In 1 Ml Ampoule 437 Carboprost Injection 250 Mcg In 1 Ml Amp./ Vial 438 Misoprostol Tablet 200 Mcg 439 Misoprostol Tablet 25 Mg 440 Dinoprostone Gel 0.5 Mg, 3 Gm 441 Isoxsuprine Tablet 10 Mg 442 Isoxsuprine Injection 5 Mg/ Ml,2Ml Ampoule 443 Valethamate Injection 8 Mg/Ml 444 Betamethasone Injection 4Mg/Ml 445 Chlorpromazine (Hydrochloride) Tablet 100 Mg 446 Fluphenazine Injection 25 Mg, 1 Ml Ampoule 447 Haloperidol Tablet 5 Mg 448 Haloperidol Injection 5Mg/1 Ml, 1 Ml Amp 449 Haloperidol Injection Long Acting 50 Mg 450 Risperidone Tablet 2 Mg 451 Risperidone Tablet 4 Mg 452 Risperidone Injection Long Acting 25 Mg 453 Quetiapine Tablet 50 Mg 454 Quetiapine Tablet Sr 100 Mg 455 Aripipralzole Tablet 10 Mg 456 Aripiprazole Tablet 15 Mg 457 Aripiprazole Tablet 5 Mg 458 Olanzapine Tablet 20 Mg 459 Olanzapine Tablet 10 Mg 460 Olanzapine Injection 405 Mg 461 Olanzapine Injection 10 Mg 462 Olanzapine Injection 210 Mg Long Acting 463 Olanzapine Injection 300 Mg Long Acting 464 Clozapine Tablet 100 Mg 465 Clozapine Tablet 50 Mg 466 Amitriptyline Tablet 10 Mg 467 Amitriptyline Tablet 25 Mg 468 Fluoxetine Capsule 20 Mg 469 Imipramine Tablet 25 Mg 470 Sertraline Tablet (Sr) 50 Mg 471 Sertraline Tablet 100 Mg 472 Escitalopram Tablet 10 Mg 473 Paroxetine (Cr) Tablet 25 Mg 474 Paroxetine Tablet (Cr) 12.5 Mg 475 Capsule Venalafaxine Extended Release 37.5 Mg 476 Capsule Venalafaxine Extended Release 75 Mg 477 Gabapentin + Nortriptyline (400/10Mg) Tablet 478 Mirtazapine Tablet 15 Mg 479 Dothiepin Tablet 25 Mg 480 Lithium Carbonate Tablet 300 Mg 481 Lithium Tablet 400 Mg Sr 482 Alprazolam Tablet 0.25 Mg 483 Alprazolam Tablet 0.5 Mg 484 Donepezil Tablet 5 Mg 485 Donepezil Tablet 10 Mg 486 Clonazepam Tablet 0.5 Mg 487 Clonazepam Tablet 1 Mg 488 Donepezil Injection 10 Mg 489 Etizolam Tablet 0.50 Mg 490 Duloxetine Tablet 30 Mg 491 Bupropion Tablet 150 Mg 492 Buprinorphine Tablet 2 Mg 493 Buprinorphine Tablet 0.4 Mg 494 Disulfiram Tablet 250 Mg 495 Disulfiram Tablet 500 Mg 496 Nicotin Chewgum 2 Mg 497 Nicotin Chewgum 4 Mg 498 Naltrexone Tablet 50 Mg 499 Amisulpride Tablet 50 Mg 500 Pregablin 75Mg +Methylcobalmin 1500Mg +Nortriptylline 10Mg 501 Methylphenidate Tablet 5 Mg 502 Memantine Tablet 5 Mg 503 Tranylcypromine Tablet 5 Mg 504 Desvenlafaxine Tablet 50 Mg 505 Buprenorphine Transdermal Patch 10 Mcg/Hour 506 Buprenorphine Transdermal Patch 20 Mcg/Hour 507 Lacosamide Tablet 100 Mg 508 Blonanserin Tablet 4 Mg 509 Breviteracetam Tablet 50 Mg 510 Eeg Paste 511 Agomelatine Tablet 25 Mg 512 Vortioxetine Tablet 10 Mg 513 Melatonin Tablet 3 Mg 514 Tadalafil 10 Mg 515 Perampenel 2 Mg 516 Fluvoxamine 150 Mg 517 Ursodeoxycholic Acid Tablet 300 Mg 518 Cariprazine Tablet 1.5 Mg 519 Atomoxitine Capsule 10 Mg 520 Betahistine Tablet 8 Mg 521 Lamotrigine Tablet 25 Mg 522 Salbutamol Tablet 4 Mg 523 Salbutamol Syrup 2 Mg/5 Ml, 100 Ml Bottle 524 Salbutamol Inhaler Areosol 100 Microgram/ Dose, Mdi, Single Packing 525 Salbutamol Nebulizer /Respirator Sol. 2.5Mg, 2.5Ml Respule 526 Etophylline + Theophylline Tablet 231 Mg + 69 Mg (Sr) 527 Etophylline + Theophylline Injection 169.4 Mg + 50.6 Mg/2 Ml Ampoule 528 Budesonide Inhalation 200 Mcg/Dose, 200 Mdi/Dpi 529 Budesonide Nasal Spray 100 Mcg/Dose, Single Unit 530 Budesonide Respirator Solution For Use In Nebulizer 1 Mg, 2Ml Respule 531 Ipratropium Respirator Solution For Use In Nebulizer 250Mcg/ 1Ml, 2 Ml Respule 532 Cough Expectorent (Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg 533 Aminophylline Injection 25 Mg/ Ml, 10 Ml Ampoule 534 Budesonide + Formoterol Inhalation (200 Mcg + 6 Mcg), 120 Mdi 535 Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml Bottle 110 Ml Bottle 536 Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml Bottle - 537 Cough Syrup Ambroxol 15 Mg+ Terbutaline Sulphate 1.25 Mg+ Guaiphenesin 50 Mg+ Menthol 2.5 Mg, 100 Ml Bottle 538 Doxofylline Tablet 400 Mg 539 Dextromethorphan (15Mg/5Ml)+Chlorpheniramine Maleate (2Mg/5Ml) +Phenylephrine Hcl (5Mg/Ml) Oral Syrup, 100 Ml Bottle 540 Caffeine Citrate Injection 20 Mg/Ml (Equivalent To 10 Mg Caffeine Base/Ml) 541 Caffeine Citrate Oral Solution 20 Mg/Ml,3Ml 542 Clarithromycin Tablet 500 Mg 543 N- Acetylcysteine Tablet 600 Mg 544 Glycopyrronium 25 Mcg + Formoterol Fumarate 12 Mcg Rota Caps 545 Oral Glucose 75 Gm 546 Dextrose Intravenous Infusion Ip 5 % W/V , 500 Ml Ffs Bottle 547 Dextrose Intravenus Infusion Ip 10% W/V, 500 Ml Ffs Bottle 548 Dextrose Intravenous Infusion Ip 25% W/V, 100 Ml Ffs Bottle 549 Dextrose 5 % W/V With Sodium Chloride 0.9% W/V For Intravenous Infusion 500 Ml Ffs Bottle 550 Multi Electrolyte Injection (Isolyte P Multiple Electrolyte & Dextrose Injection Type 1 ), 500 Ml Ffs Bottle 551 Potassium Chloride Oral Solution 10%, 100 Ml Bottle 552 Potassium Chloride (Solution) Injectable 15% (150Mg/Ml) , 10 Ml Amp. 553 Ringer Lactate (Solution ) For Injection ( Compound Sodium Lactate) 500 Ml Ffs Bottle 554 Normal Saline (Sodium Chloride) Injection Solution 0.9% Isotonic, 100Ml 555 Normal Saline Injection 3% 556 Normal Saline (Sodium Chloride) Injection 0.9% W/V, 500 Ml Bottle ( Ffs Technology) 557 Water For Injection 5Ml Ampoule 558 Injection Human Albumin 5% Infusion Solution 5% 559 Injection Human Albumin 20% Infusion Solution 20 560 Ascorbic Acid Tablet 500 Mg 561 Pyridoxine Tablet 10 Mg 562 Pyridoxine Tablet 100 Mg 563 Vitamin A Oral Solution 100000 Iu/Ml, 100 Ml 564 B-Complex Tablet 565 Vitamin D3 Drops 400 Iu/Ml 566 Vitamin D3 Tablet (Chewable) 60000Iu 567 Calcium Salts 500 Mg+ Vitamin D3 250 Iu Tablet 568 Thiamine Injection 100 Mg/Ml, 2 Ml Vial 569 Calcium Phosphate Suspension/Syrup:- Each 5Ml Contains: Vit D3 (Cholecatciferol) Ip-200Iu Vitamin B12 (Cyanocobalamin) Ip 2.5Mcg, Calcium- 82Mg (As A Mixture Of Calcium Phosphats Calculated As 0.12G Ca3 (Po4) 2 Suspension/Flavoured Syrupy Base- Q.S. 200Ml Bottle. 570 \Hematinic With Amino Acids Vitamin And Zinc Syrup 200 Ml Bottle, Each 10 Ml Contains: Ferrous Glycine Sulphate-216.50Mg, L-Histidine Hcl-25.0 Mg, Pyridoxine Hydrochloride Ip-1.5 Mg, Nicotinamide Ip-25.0 Mg, Folic Acid Ip-0.5 Mg, Cyanocobalamin Ip-2.5 Mcg, Zinc Ascorbate 50 Mg, Approved Colors Used\ 571 Multi Vitamin Infusion 10 Ml: Each Ml Contains Vitamin A (As Vitamin A Concentrate Oily Form) Lp 1100 Lu, Cholecalciferol Lp 100 Lu, Tocopheryl Acetate Lp 0.5Mg, Nicotinamide Lp 10Mg, Riboflavin Sodium Phosphate Lp 1.4Mg, Pyridoxine Hydrochloride Lp 1.65Mg, Thiamine Hydrochloride Lp 5.0Mg, Ascorbic Acid Ip 50.0Mg, L-Cysteine Hydrochloride Usp 0.2Mg, Benzyl Alcohol (As Preservative) Lp 1.0% V/V, Water For Injections Lp Q.S 572 Methylcobalamin Tablet 1500 Mcg 573 Pregabalin 75 Mg+ Methylcobalamin 1500 Mcg Tablet 574 Alfacalcidol Soft Gelatin Capsule 0.25 Mcg 575 Biotin Tablet 10 Mg 576 Thiamine Tablet 100 Mg 577 10 Essential Amino Acid With Vitamins And Minerals Capsules (10X10) 578 Amino Acid Iv Infusion Minimum 10 Essential Amino Acids, 250Ml Bottle - 579 Artesunate Injection 60 Mg/Ml 580 Chloroquine Phosphate Injection 40 Mg/Ml 581 Chloroquine Phosphate Tablet 250 Mg, Equivalent To 155 Mg Chloroquine Base 582 Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50 Ml Bottle 583 Primaquine Tablet 2.5 Mg 584 Primaquine Tablet 7.5 Mg 585 Primaquine Tablet 15 Mg 586 Quinine Sulphate Tablet 300 Mg 587 Quinine Dihydrochloride Injection 300 Mg/Ml, 2 Ml Ampoule 588 Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg 589 Temphos 50% Ec 5 Liter Pack 590 Malathion Technical 95%, 250 Kg 591 Deltamethrin 2.5% Wp, 25 Kg 592 Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) 593 Bivalent Antigen Based Rapid Diagnostic Kit For Malaria 594 Pyrethrum Extract 2% 595 Dengue Ns1 Antigen Elisa Based Test Kit,96 Test/Kit - 596 Mac Elisa Igm Dengue Kit 597 Sofosbuvir 400 Mg Tablet + Ledipasvir 90 Mg Tablet 598 Sofosbuvir 400 Mg Tablet 599 Daclatasvir 60 Mg Tablet 600 Daclatasvir 30 Mg Tablet 601 Entecavir 1 Mg Tablet 602 Entecavir 0 .5 Mg Tablet 603 Ribavirin Capsules 200 Mg 604 Tenofovir Tablet 300 Mg 605 Sofosbuvir 400Mg+ Velpatasvir 100 Mg Tablet 606 Rtpcr Kits For Quantitative Viral Load Test For Hepatitis B Virus 607 Rtpcr Kits For Quantitative Viral Load Test For Hepatitis C Virus 608 Storage Vial 5 Ml 609 Racked Filter Pipette Micro-Tips(Sterile) 10 Ul 610 Racked Filter Pipette Micro-Tips(Sterile) 20 Ul 611 Racked Filter Pipette Micro-Tips(Sterile) 1000 Ul 612 Racked Filter Pipette Micro-Tips(Sterile) 200 Ul 613 Filter Pipette Micro-Tips (Sterile) 10 Ul 614 Filter Pipette Micro-Tips (Sterile) 20 Ul 615 Filter Pipette Tips (Sterile) 100 Ul 616 Filter Pipette Tips (Sterile) 200 Ul 617 Filter Pipette Tips (Sterile) 1000 Ul 618 Ethanol Imported (20 Bottles Per Bottle) 5 Liter Pack 619 Molecular Biology Grade Water As Per Requirement 620 Screw Capped Storage Vial 2Ml (500 Vials) Per Pack 2 Ml 621 100 Well Micro Tube Storage Box 622 Para Film 623 Blue Nitrile Gloves 624 Single Channel Variable Volume Micropipette 0.5-10 Ul 625 Single Channel Variable Volume Micropipette 02-20 Ul 626 Single Channel Variable Volume Micropipette 05-50 Ul 627 Single Channel Variable Volume Micropipette 10-100 Ul 628 Single Channel Variable Volume Micropipette 20-200 Ul 629 Single Channel Variable Volume Micropipette 100-1000 Ul 630 96 Well Qper Plates With Adhesive Optical Scaling Membrane 631 Individual Pcr Tubes 8-Tube Strips(Clear) 632 Optical Flat 8-Cap Strips 0.2Ml Tube Strips 633 8 Channel Variable Value Micropipette 2-20 Ul 634 Micro Centrifuge Tubes Mctival (Sterile) 2 Ml 635 96 Well Reversible Rack F 0.5 To 2.0Ml Vials 636 Rnase And Dnase Degradation Solution 637 Rnase And Dnase Degradation Solution Wipes 638 Dna Blood Extraction Kit 639 Viral Rna Extraction Kit 640 Purified Freeze €“ Dried Human Coagulation Factor Viii, Virus Inactivated Injection 250 Iu 641 Anti Hemophillic Factor Ix Vial Injection Size 500 Iu 642 Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule 643 Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole 644 Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 500 Iu,Vial/Ampoule 645 Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 1000 Iu,Vial/Ampoule 646 Recombinant Anti Haemophilic Factor Viii (Rf Viii)Standard Half Life Injection 250 Iu 647 Recombinant Anti Haemophilic Factor Viii (Rf Viii)Extended Half Life Injection 500 Iu 648 Recombinant Anti Haemophilic Factor Ix(Rf Ix )Standard Half Life Injection 250 Iu 649 Recombinant Anti Haemophilic Factor Ix (Rf Ix)Extended Half Life 500 Iu 650 Emicizumab-Kxwh Injection 30 Mg/Ml 651 Emicizumab-Kxwh Injection 60 Mg/0.4 Ml 652 Anti Haemophilic Factor Ix Vial Injection 600Iu 653 Leuco Reduction Filter Bed Side For Packed Red Blood Cells - 654 Sanitary Napkin 655 Weekly Iron Folic Acid Tablet Each Tablet Containing 60 Mg Elemental Iron+500 Mcg Folic Acid, Sugar Coated ,Blue Colour 656 Iron And Folic Acid Tablet ( Wifs Junior ) Containing Dried Ferrous Sulphate Ip Equivalent To Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet. Tablet Are Sugar Coated And Pink Coloured Tablets With Only Edible Colours Used Tablet Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet 657 Salt Testing Kit 658 Oseltamivir Tablet 75 Mg 659 Oseltamivir Tablet 45 Mg 660 Oseltamivir Tablet 30 Mg 661 Oseltamivir Syrup (Each 1 Ml Reconstituted Suspension Contain 12 Mg Oseltamivir, 75 Ml Bottle) Syrup 662 Seasonal Influenza Quadrivalent/ Tetravalent Vaccine 663 Deferiprone Tablet 500 Mg 664 Deferasirox Tablet 500 Mg 665 Desferrioxamine Injection 500 Mg 666 Medroxyprogesterone Acetate Injection Ip (Dmpa ) 25 X 1X 1Ml (Contraceptive Injection For Im Use Only) 667 Single Blood Bags 350 Ml 668 Double Blood Bags 350 Ml 669 Triple Blood Bags 450 Ml 670 Quadruple Blood Bags 450 Ml 671 Double Blood Bag 450 Ml 672 Triple Blood Bags 350 Ml 673 Triple Blood Bag With Sagm 350 Ml 674 Triple Blood Bag With Sagm 450 Ml 675 Quadruple Blood Bag With Sagm 350 Ml 676 Quadruple Blood Bag With Sagm 450 Ml 677 Hiv Elisa (96 Test Each) 678 Hbsag Elisa (96 Test Each) 679 Hcv Elisa (96 Test Each) 680 Hiv Rapid (30 Test Each) 681 Hbsag Rapid (30 Test Each) 682 Hcv Rapid (30 Test Each) 683 Rpr/Vdrl (50 Test Each) 684 Reagents Anti-A, Anti-B, Anti-D Sera 685 Reagents Anti-Ab Serum 686 Reagents Antihuman Globulin Serum 687 Reagents Anti-A1 (Lectin) Serum 688 Reagents Bovine Albumin 22% 689 Aprepitant 80Mg (Kit Contains 3 Caps) 690 Aprepitant Kit 120 Mg 691 Bleomycin Injection 15 Mg, 15 Mg/Ml Vial 692 Capecitabine Tablet 500 Mg 693 Capecitabine Tablet 1000 Mg 694 Carboplatin Injection 150 Mg, 10 Mg/Ml Vial 695 Carboplatin Injection 450 Mg, 10Mg/Ml Vial 696 Cisplatin Injection 50 Mg, 1 Mg/Ml Vial 697 Cisplatin Injection 10 Mg 698 Cyclophosphamide Injection 1000Mg, 1.33Mg/Ml Vial 699 Cyclophosphamide Injection 500Mg, 10Mg/Ml Vial 700 Cyclophosphamide Tablet 50 Mg 701 Dacarbazine Injection 200 Mg, 10Mg/Ml Vial 702 Dacarbazine Injection 500 Mg 703 Docitaxel Injection 120 Mg, 20Mg/ 0.5 Ml Vial 704 Doxorubicin (Hydrochloride Powder) Aqueous Solution 10Mg/2Ml 705 Doxorubicin (Hydrochloride Powder) Aqueous Solution 50 Mg/ 2 Ml Vial 706 Epirubicin Injection 50 Mg, 2Mg/Ml Vial 707 Epirubicin Injection 10 Mg, 2Mg/Ml Vial 708 Etoposide Injection 100Mg, 20Mg/Ml Vial 709 Etoposide Capsule 50 Mg 710 5-Fluorouracil Injection 500Mg, 50Mg/Ml Ampules 711 Fluorouracil Injection 1 Mg 712 Filgrastim Injection 300Mcg, 300Mcg/0.5 Ml Prefilled Syringe 713 Peg Filgrastim Injection 6 Mg 714 Geftinib Tablet 250 Mg 715 Gemcitabine Injection 200Mg, 100Mg/Ml Vial 716 Gemcitabine Injection 1000Mg, 10Mg/Ml Vial 717 Imatinib Tablet 400 Mg 718 Isophosphamide Injection 200Mg, 100Mg/Ml Vial 719 Lenalidomide Tablet 10 Mg 720 Letrozole Tablet 2.5 Mg 721 Oxaliplatin Injection 50Mg, 5Mg/Ml Vial 722 Oxaliplatin Injection 100Mg, 5Mg/Ml Vial 723 Paclitaxel Injection 260Mg, 10Mg/1.67 Ml Vial 724 Pemetrexate Injection 500Mg, 25Mg/Ml Vial 725 Tamoxifen Citrate Tablet 20 Mg 726 Tamoxifen Citrate Tablet 10 Mg 727 Vinblastine Injection 10 Mg, 1Mg/Ml Vial 728 Vincristine Injection 1 Mg, 1Mg/Ml Vial 729 Ateplase Injection 20 Mg 730 Ateplase Injection 50 Mg 731 Tenecteplase Injection 20 Mg 732 Rituximab Injection 500 Mg 733 Methotrexate Injection 50 Mg 734 Methotrexate Tablet 50 Mg 735 Zolidronic Acid Injection 4 Mg 736 Actinomycin Injection 0.5 Mg 737 Goserline Injection 10.8 Mg 738 Luperolide Injection 22.5 Mg 739 Degaralix Injection 240 Mg 740 Thalidomide Tablet 100 Mg 741 Exemestene Tablet 1 Mg 742 Sunitinib Tablet 50 Mg 743 Pazopanib Tablet 200 Mg 744 Dexamethasone Tablet 4 Mg 745 Dexamethasone Tablet 8 Mg 746 Erlotinib Tablet 100 Mg 747 Morphine Tablet 10 Mg 748 Morphine Tablet 30 Mg Sr 749 Buprinorphine Patch 5 Mg 750 Buprinorphine Patch 10 Mg 751 Buprinorphine Patch 15 Mg 752 Iohexol Injection 300 Mg 753 Zoledronic Acid Injection 4 Mg 754 Trastuzumab Injection 150 Mg 755 Trastuzumab Injection 450 756 Onco Bcg Injection 757 Onco Bcg 80Mg Injection 758 Mitomycin Injection 40 Mg 759 Granisetron Injection 1 Mg 760 Leucovorin Injection 50 Mg 761 Bortezomib Injection 2 Mg 762 Ifosfamide Injection 1 Gm 763 Mesna Injection 400 Mg 764 Carfilzomib Injection 60 Mg 765 Bicalutamide Tablet 50 Mg 766 Sorafenib Tablet 200 Mg 767 Temozolamide Tablet 100 Mg 768 Temozolamide Tablet 250 Mg 769 Clindipine Tablet 10 Mg 770 Codon Set 771 Codon I/V Set Woth Air Vent & 0.2 Micron Filter 772 Granisetron Injection 3 Mg 773 Reteplase Injection 10.4 U(18.1 Mg) Kit 774 Meropenum Injection 125 Mg 775 Meropenum Injection 500 Mg 776 Piperacillin 1 Gm + Tazobactum 0.12Gm Injection 777 Piperacillin 4 Gm + Tazobactum 0.5Gm Injection,Vial Injection 4 Gm+ 0.5 Gm 778 Netilmycin Injection 25Mg/Ml 779 Ethamsylate Injection 250 Mg/2 Ml 780 Dns ( Sodium Chloride And Dextrose, Each 100 Ml Contains Dextrose 5 Gm, Nacl 0.9 G) 781 Calcium Syrup Each 5 Ml Contains Calcium 250Mg, Vitamin D3 125 Iu 782 Simyl Mct Oil (Medium Chain Triglycerides And Permitted Antioxidants (Tocopherol Accetate) 783 Ecg Electrodes (Neonate) 784 Umbilical Catheter No. 5, (5 Fr Length 37 Cm, -31Ml/Min Pvc 785 Umbilical Catheter No. 6 (6 Fr Length 37 Cm, -31Ml/Min Pvc 786 Oxygen Tubing, Suction Tubing (Different Colours) 787 Triway (Three Way Stop Clock) Lipid Resistant Pyrogen Free, Sterile, Latex Free 788 Bone Narrow Needle For Neonates 18 G 789 Blood Lancets For Glucometer 790 Grip Lock 791 Picc Line 24 G, 28 G 792 Suction Plain Catheter No. 6, Disposable Pyrogen Free 793 Suction Plain Catheter No. , 8 Disposable Pyrogen Free 794 Oxygen Hood For Neonates 795 T- Connector 796 Y- Connector For 8-10 Mm 797 Nasal Prongs Term & Preterm Single Patient Use With Twin Bore Nasal Pronges Sets, Extra Soft Medical Grade Nasal Tips 798 Nasal Prongs Preterm (Pead) 3.0 & 3.7 Mm - 799 Octopus Bi Connector (Length 1-10 Cm 1.5*2.5, 2-10 Cm 1.5*2.8)Pur Vol- 0.57 Ml 800 Q-Way 6 Inches ,Sterlized Using Ethylene Oxide 801 Tegaderm 2, 3/8 Inch*2.3/4 Inch 6*7 Cm Tegaderm Tm Films Iv Transparent Film Iv Transparent Film Dressing Style(Latex Free) 802 Uro Bag (Neonates)- 100 Ml 803 Dyna Plast Adhesive Tape ( 10 Cm Width, 5 Cm Length) 804 Surfactant- Survanta(Synthetic)(25 Mg/1Ml), Exosurf (Bovine) 805 Micro Drip Set 806 Transpore 2\ 807 Transpore 4\ 808 Chest Drain (Adults) 809 Disposable Needle 24 810 Anti Diptheria Serum 811 Td Vaccine 812 Erythromycin Tablet 250 Mg 813 Erythromycin Syrup 125 Mg/5 Ml, 60 Ml 814 Hepatitis B Vaccine (R Dna) I.P. 815 Urine Screening Through Dry Chemistry Rapid Testing Kit/Strips For Multiple Drug Uses:- 1. Morphine/ Opiates 2. Buprenorphine 3. Tramadol 4. D. Propoxyphene 5. Benzodiazepines Test Kit Kit 816 Nicotine Patches 817 1.Nicotine Patches 7Mg 2. Nicotine Patches 14Mg 818 Nicotine Pastilles 2 Mg 819 Nicotine Pastilles 4 Mg 820 Tablet Vareniciline 0.5Mg 821 Tablet Vareniciline 1 Mg 822 Tablet Buspirone 5 Mg 823 Anti Rabies Vaccine Through Id Route, 1 Ml Vials Vaccine 1Ml. 824 Tenofovir 300 Mg+ Lamivudine 300 Mg Tablet 825 Dolutegravir Tablet 50 Mg 826 Dual Kits For Hiv And Syphilis - 827 Levofloxacin Tablet 250 Mg 828 Pyridoxine Tablet 50 Mg 829 Moxifloxacin Tablet 400 Mg 830 Cbnaat Tb Cartridges - 831 Cbnaat-Xdr Cartriges 832 Ethambutol Tablet 100 Mg 833 Ethambutol Tablet 400 Mg 834 Ethambutol Tablet 800 Mg 835 Clofazimine Tablet 100 Mg 836 Clofazimine Tablet 50 Mg 837 Cycloserine Capsule 250Mg 838 Delamanid Tablet 50 Mg 839 Bedaquiline (Bpq) - L Tablet 840 Ethinamide Tablet 250 Mg 841 Isoniazid Tablet 100 Mg 842 Isoniazid Tablet 300 Mg 843 3 Hp Isoniazid Plus Rifapentine Fdc (300Mg/300Mg) Tablet 844 Rifapentine Tablet 150 Mg 845 Rifapentine Tablet 300 Mg 846 Rifampicin Tablet 150 Mg 847 Truenat Mtb Chips Test Kit 848 Truenat (Rip Chips) Test Kit - 849 Bbl Mgit Tubes For Use In Bactec Mgit 960 (7Ml) - 100 Tubes/Pkg Catalouge No 245122 850 Bactec Mgit 960 Supplement Kit (100 Tests, Panta And Oadc Combined) Catalogue No: 245124 Kit - 851 Bactec Mgit 960 Sire Kit. One Kit Is Sufficient For 40 Test Catalogue No: 245123 852 Genotype Mtbdr Si V2.0 96 Test 31796Am. Test Kits Composed Of 31796 A Genotype Mtbdr Si V2.0 - 853 Genotype Mtbdr Plus V2.0 30496 Am. Test Kits Composed Of 30496A Genotype Mtbdr Plus Version 2.0 And 51610 Genolyse - 854 Gt Blot 48 Reagent Kits 855 Genolyse 96 Test 51610 856 2Fdc (P) (H50 & R75) 857 3Fdc Cp (A) (H75, R150 & E275) 858 3Fdc (P) (H50, R75, Z150) 859 4Fdc (A) (H75, R150, Z400 & E275) 860 Tablet Ethambutol 100 Mg 100 Mg 861 Rifampicin Tablet 300 Mg 862 Genolyse 96 Test 51610 - 863 Early Childhood Development (Ecd) Kit For Ashas - 864 Absorbant Cotton Gauze, 90 Cm X 18 Mtrs, Is No: 758:2023, Specification Mentioned Under Mdr-2017 As Amended From Time To Time ( 1X 5 Than) 865 Cotton Bandage Cloth, 15 Cm X 5 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) 866 Cotton Bandage Cloth, 10 Cm X 4 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) 867 Cotton Bandage Cloth, 5 Cm X 4 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) 868 Crape Bandages Bp(1 X 10 Rolls) 10 Cm X 4.5 Mtrs 869 Crape Bandages Bp(1 X 10 Rolls) 15 Cm X 4.5 Mtrs 870 Plaster Of Paris Bandages B.P. (1 X 10 Rolls) 10 Cm X 2.7 Mtrs, (High Strength) 871 Plaster Of Paris Bandages B.P (1 X 10 Rolls) 15 Cm X 2.7 Mtrs, (High Strength) 872 Cotton Wool Ip 100 Gm 873 Cotton Wool Ip 500 Gm 874 Orthopadding Cast/Zigzag Cotton Roll 4\ 875 Orthopadding Cast/Zigzag Cotton Roll 6\ 876 Disposable Syringes 2 Ml, (24G), Ribbon Pack 877 Disposable Syringes 5 Ml, (23G), Ribbon Pack, Reuse Preventable 878 Disposable Syringes 10 Ml. With Needle, Ribbon Pack 879 Disposable Syringes 2 Ml, (23G), Ribbon Pack 880 Disposable Syringes 1 Ml (23G), Ribbon Pack 881 Disposable Insulin Syringe (31G), Ribbon Pack 882 Disposable Syringe 20 Ml With Needle, Ribbon Pack 883 Disposable Syringe 50 Cc With Needle, Ribbon Pack 884 Disposable Syringes 2 Ml, (24G) Reuse Preventable 885 I.V. Canulas 24 With Luer Lock 886 I.V. Canulas 22 With Luer Lock 887 I.V. Canulas 20 With Luer Lock 888 I.V. Canulas 18 With Luer Lock 889 I.V. Canulas 16 With Luer Lock 890 I.V. Canulas 26 With Luer Lock 891 I.V.Sets Disposable With Air Vent 892 Blood Administration Set/Blood Transfusion Set. Transparent Cylindrical Drip Chamber With 200 Micron Filter. 150 Cm Long Smooth Kink Resistant Tubing. 893 Pedeatrics Iv Drip Set With Air Vent 894 Sterile Disposable Spinal Needle For Single Use 23G X 3 1/2 Inch 895 Sterile Disposable Spinal Needle For Single Use 25G X 3 1/2 Inch Clear/ Transparent Hub 896 Sterile Disposable Spinal Needle For Single Use 22 G X 3 1/2 Inch Clear/ Transparent Hub 897 Sterile Disposable Spinal Needle For Single Use 24 G X 3 1/2 Inch Clear/ Transparent Hub 898 Sterile Disposable Spinal Needle For Single Use 26 G X 3 1/2 Inch Clear/ Transparent Hub 899 Sterile Disposable Spinal Needle For Single Use 18 G X 3 1/2 Inch Clear/ Transparent Hub 900 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +17D 901 Endotracheal Tube, Cuffed No. 5.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.0Mm - 902 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +18D 903 Endotracheal Tube, Cuffed No. 6.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 6.0Mm - 904 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +19D 905 Endotracheal Tube, Cuffed No.6.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 6.5Mm - 906 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +20D 907 Endotracheal Tube, Cuffed No. 7.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 7.0Mm - 908 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +21D 909 Endotracheal Tube, Cuffed No. 7.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 7.5Mm - 910 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +22D 911 Endotracheal Tube, Uncuffed No. 4.5 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 4.5Mm - 912 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +23D 913 Endotracheal Tube, Uncuffed No. 2.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 2.5Mm - 914 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +24D 915 Endotracheal Tube, Uncuffed No. 3.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 3.0Mm - 916 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +25D 917 Endotracheal Tube, Uncuffed No. 3.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 3.5Mm - 918 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +17D 919 Endotracheal Tube, Uncuffed No.4.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 4.0Mm - 920 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +18D 921 Endotracheal Tube, Uncuffed No. 5.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.0 Mm - 922 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +19D 923 Endotracheal Tube, Cuffed No. 5.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.5Mm - 924 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +20D 925 Endotracheal Tube, Cuffed No. 8.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 8.0Mm - 926 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +21D 927 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +22D 928 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +23D 929 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +24D 930 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +25D 931 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +17D 932 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +18D 933 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +19D 934 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +20D 935 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +21D 936 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +22D 937 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +23D 938 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +24D 939 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +25D 940 Infant Feeding Tube 4 941 Infant Feeding Tube 5 942 Infant Feeding Tube 7 943 Infant Feeding Tube 9 944 Infant Feeding Tube, Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile, Size: 6Fg 945 Infant Feeding Tube, Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile, Size: 8Fg 946 Infant Feeding Tube:Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile 10 Fg 947 Ryles Tube 8 948 Ryles Tube 10 949 Ryles Tube 12 950 Ryles Tube 14 951 RyleS Tube/ Nasogastric Tube (P.V.C) With Radio Opaque Lining. Size:16, Soft , Kink Resistant Pvc Tubing For Atraumatic Intubation, Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation, Four Lateral Eyes For Greater Efficiency, Radio Opaque Line, Marking At 50, 60, 70 Cm From Tip, Colour Coded Funnel, With Luer Connector/Closure, Length 105 Cm 952 Mucous Suction Trap 953 Foleys Catheter 8 954 Foleys Catheter 10 955 Foleys Catheter 12 956 Foleys Catheter 18 957 Foleys Ballon Catheter 2 Way ( Silicon Elastomer ) Non- Toxic Pyrogen Free Sterile For Single Use Only , Size 14, Single Sterile Packing 958 Foleys Ballon Catheter 2 Way ( Silicon Elastomer ) Non- Toxic Pyrogen Free Sterile For Single Use Only , Size 16, Single Sterile Packing 959 Urine Bag 2000 Ml, Single Unit Packing 960 Disposable Surgical Gloves No. 6.5, Isi Mark 961 Disposable Surgical Gloves No. 7, Isi Mark 962 Disposable Surgical Gloves No. 7.5, Isi Mark 963 Disposable Surgical Gloves No.6 , Isi Mark 964 Examination Gloves (Medium Size), Isi Mark 965 Micropore/Surgical Paper Tape 25Mm X 9.1Mtr. 966 Micropore/Surgical Paper Tape 50Mm X 9.1 Mtr. 967 Micropore/Surgical Paper Tape 75Mm X 9.1 Mtr. 968 Disposable Shoe Cover 969 Disposable Mask 970 Disposable Cap 971 Sterile Cord Clamp Non Toxic, Pyrogen Free Sterile For Single Use Only Single Unit Packing 972 Ecg Electrodes (Disposable Kit) Pack Of 6 973 Ot Sponges With Radio-Opaque Thread (With 8 Layers 30 Cm X 30 Cm ) 974 Carbolic Acid 400 Ml 975 Opsite Eye Drape Sheet With Drain Pouch 70 Cm X 70 Cm 976 Blades For Eye Surgery Crescent 977 Blades For Eye Surgery Side Port 15° 978 Blades For Eye Surgery Keratones 2.8 Mm 979 Blades For Eye Surgery Implant 5.2 Mm 980 Karman/ Mtp Cannula No. 6, Single Unit 981 Karman/ Mtp Cannula No. 7, Single Unit 982 Karman/ Mtp Cannula No. 8, Single Unit 983 Mr Cannula No. 5 984 Mr Cannula No. 6 985 Mr Cannula No. 7 986 Mr Cannula No. 8 987 Disposable Sterile ,Powder Free Gloves For Eye Surgeries Surgical Gloves 6.5 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 6.5 988 Disposable Sterile, Powder Free Gloves For Eye Surgeries Surgical Gloves 7 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 7 989 Disposable Sterile, Powder Free Gloves For Eye Surgeries Surgical Gloves 7.5 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 7.5 990 Ecg Paper 215 Mm*20 Mtr, Roll 991 Ecg Paper 50 Mm*20 Mtr, Roll 992 Ecg Paper 50 Mm*30 Mtr, Roll 993 Ecg Paper 60 Mm* 15 Mtr, Roll 994 Ecg Roll Big 995 Ecg Roll Small 996 Ecg Jelly 200 Ml Bottle 997 Ultrasound Jelly 200 Ml Bottle 998 Absorbable Gelatin Sponge, 80 X 50X 10 Mm, Single Unit 999 Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 6 Cm X 11 Cm (3 To 6 Units Of Mesh In One Box). 1000 Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 15 Cm X 15 Cm (3 To 6 Units Of Mesh In Each Box) 1001 Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) 1002 Multilayer Tissue Separating Mesh With Polypropylene/Polyster And Polydioxanone /Collegen. 15Cm X 15 Cm Square /Circular 1003 Surgical Spirit Bp 500 Ml 1004 Sodium Hypochlorite Solution 10% 1005 Acetone 400 Ml 1006 Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging 1007 Ortho-Phthaldehyde 0.55% W/W Solution For Sterlization, 5 Liter 1008 Potassium Peroxomonosulphate 50% W/W Containig Aldehyde Free Disinfectant , 5 Kg 1009 Dark Eye Glasses 1010 Disposable Eye Patch 1011 I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye) 1012 Surgical Blades11 (Pack Of 100) 1013 Surgical Blades15 (Pack Of 100) 1014 Surgical Blades20 (Pack Of 100) 1015 Surgical Blades23 (Pack Of 100) 1016 Surgical Blades 24 (Pack Of 100) 1017 Oxygen Venti-Mask (Pvc/Disposable)Adult 1018 Oxygen Venti-Mask (Pvc/Disposable)Medium 1019 Oxygen Venti-Mask (Pvc/Disposable)Paed. 1020 Nebulisation Set (Mask With Tubing With Chamber (Adult ) 1021 Nebulisation Set (Mask With Tubing With Chamber (Paediatric ) 1022 Diaper Paediatric (Extra Small Size For Neonates) 1023 Disposable Adhesive Cannula Fixator 1024 Patient Identification Band Mother & Child Size (Different Colours) 1025 Patient Identification Band Adult Size (Different Colours) 1026 Patient Identification Band Paediatric Size (Different Colours) 1027 Suction Catheter No. 10 , Single Unit 1028 Suction Catheter No. 16 , Single Unit 1029 Negative Suction Drain/Closed Round Drain 12 1030 Negative Suction Drain No.14 1031 Negative Suction Drain No. 16 1032 Disposable Plastic Urine Pan 1033 Disposable Plastic Bed Pan 1034 Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm 1035 Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm 1036 Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 6.5 Cm X 5 Cm (Pack Of 100) 1037 Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 15.5 Cm X 8.5Cm (Pack Of 100) 1038 Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 25 Cm X 10 Cm , (Pack Of 100) 1039 Skin Stapler Standard ( Single Unit) 1040 Airway Set Size 2, ( Single Unit) 1041 Airway Set Size 3, ( Single Unit) 1042 Airway Set Size 4, ( Single Unit) 1043 Airway Set Size 5, ( Single Unit) 1044 Ambu Bag Adult, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 7 K Pa ( 70 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 1300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) 1045 Ambu Bag Ped, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 4 K Pa ( 40 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) 1046 Courtery Lead ( Single Unit) 1047 Coutery Pad (Single Unit) 1048 Lega Clip Size Lt 300 (Titanium Ligating Clips Medium Size Having Lateral And Transverse Grooves On The Inner Clips), (Single Unit) 1049 Lega Clip Size Lt 400 (Titanium Ligating Clips Large Size Having Lateral And Transverse Grooves On The Inner Clips), (Single Unit) 1050 Shoulder Immobilizer Standard 1051 Pouch Arm Sling Standard 1052 Centre Line 1053 Cervical Collar Small Size (Soft) 1054 Cervical Collar Medium Size (Soft) 1055 Cervical Collar Large Size (Soft) 1056 Hard Cervical Collar (Universal) Size 1057 Chest Drain Catheter No.12 1058 Chest Drain Catheter No.14 1059 Chest Drain Catheter No.28 1060 Chest Drain Catheter No.32 1061 Chest Tube Drainage With Water Seal Bag No.28 1062 Chest Tube With Water Seal No.32 1063 Dj Stunt 1064 Dj Stunt No.5.5 1065 Dj Stunt No. 6 French End Closed 1066 Dj Stunt No 5/26 Both End Open 1067 Dj Stunt No 6/26 Both End Open 1068 Epidural Set 1069 Guide Wire Teflon Coated J Tip 1070 Guide Wire Teflon Coated V Straight Tip 1071 Spc Set (Suprapubic Catheter Set) 1072 Turp Loop 1073 Skin Traction Set Standard Size 1074 I.V. Flow Regulator Extension Sets 1075 Blades For Eye Surgery Keratones 3.2 Mm 1076 Balance Salt Solution (Bss For Eye Surgery) 500 Ml 1077 Craner Wire Splint 1078 Air Mattress 1079 Bb Splint (Bohler- Braun) 1080 Bed Side Pulley 1081 Skeletal Traction 1082 Disposable Needle 16 1083 Disposable Needle 23 1084 Disposable Needle 26 1085 Pmo Line 1086 Troponin T, Sensitivity:-Not Less Than 95.8%, Direct Whole Blood Test Kit 1087 3D Mesh For Lap Ingunal Hernia A)Right Side B)Left Side - 1088 Partial Absorble (10X6 Cm)Vicryl Mesh For Ipom 1089 Tackers For Mesh Fixation (Non Absorable) 1090 Measured Volume Fluid Infusion Set With 110Ml/150Ml Chamber - 1091 Medical X-Ray Films(1X50) 8\X10\ 1092 Medical X-Ray Films(1X50) 10\X12\ 1093 Medical X-Ray Films(1X50) 12\X15\ 1094 Medical X-Ray Films(1X50) 14\X14\ 1095 Medical X-Ray Films(1X50) 14\X17\ 1096 Agfa Cr Film (Dt2B)(1X100) 8\X10\ 1097 Agfa Cr Film (Dt2B)(1X100) 10\X12\ 1098 Agfa Cr Film (Dt2B)(1X100) 11\X14\ 1099 Agfa Cr Film (Dt2B)(1X100) 14\X17\ 1100 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle 1101 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle 1102 Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 63 Mm, 3/8 Circle (12 Foils In Each Box) Round Body Needle - 1103 Chromic Catgut Absorbable Suture Usp 1,76Cm Length 1/2 Circle 40Mm, Round Body Needle (12 Foils In Each Box) 1104 Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle 1105 Silk Sutupak Usp 1, 75 Cm (12 Foils In Each Box) 1106 Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) 1107 Silk Suture Usp 3-0, 90 Cm X 16 Mm , 3/8 Circle Type Of Needle- Cutting (12 Foils In Each Box) 1108 Polyglactin (Violet) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box)Should Be Antibacterial 1109 Polyglactin (Violet) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) Should Be Antibacterial 1110 Polyglactin (Violet) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box)Should Be Antibacterial 1111 Polyglactin (Plain) Vicryl Usp-1, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle Reverse Cutting - 1112 Polyglactin Synthetic Braided Absorbable Suture, Usp-1, 90Cm Length, Violet 1/2 Circle 40Mm Round Body Needle (12 Foils In Each Box) 1113 Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1114 Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (12 Foils In Each Box) 1115 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (12 Foils In Each Box) 1116 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (12 Foils In Each Box) 1117 Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1118 Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) 1119 Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle.Should Be Antibacterial. 1120 Knotless Control Device Polygecaprone 3/8 Circle Reverse Cutting Needle 24 Mm Spril Unidireectional 30Cm With Antibactreal Triclosan Coated 3/0 - 1121 Knotless Control Device Polygecaprone 1/2 Circle , 40 Mm ,Taper Point,Ct,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 1/0 - 1122 Knotless Control Device Polygecaprone 1/2 Circle , 36 Mm ,Taper Point,Ct,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 1 1123 Knotless Control Device Polygecaprone 1/2 Circle , 26 Mm ,Taper Point,Sh,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 2/0 1124 Silver Alloy Non-Gamma-2 Lathe Cut Alloy 1125 Mercury Pure Triple Distilled 1126 Cavity Varnish 5% Sodium Fluoride 1127 Calcium Hydroxide, Powder 1128 Topical Fluoride Apf Gel 1.25% 1129 Gum Paint 1130 Edta 17 % Paste Form. 1131 Pulp Devitalizer 1132 Rubber Dam Kit 1133 Air- Rotor Diamond Burs No. 1 (Inverted Bur) 1134 Air- Rotor Diamond Burs No. 1 (Straight End Taper) 1135 Air- Rotor Diamond Burs No. 1 (Round) 1136 Air- Rotor Diamond Burs No. 1 (Straight) 1137 Air- Rotor Diamond Burs No. 1 (Flame) 1138 Air- Rotor Diamond Burs No. 2 (Inverted Bur) 1139 Air- Rotor Diamond Burs No. 2 ( Straight End Taper) 1140 Air- Rotor Diamond Burs No. 2 (Round) 1141 Air- Rotor Diamond Burs No. 2 (Straight) 1142 Air- Rotor Diamond Burs No. 2 (Flame) 1143 Air- Rotor Diamond Burs No. 3 (Inverted Bur) 1144 Air- Rotor Diamond Burs No. 3 ( Straight End Taper) 1145 Air- Rotor Diamond Burs No. 3 (Round) 1146 Air- Rotor Diamond Burs No. 3 (Straight) 1147 Air- Rotor Diamond Burs No. 3 (Flame) 1148 K-Files - Size- 15-40 , Length:-21 Mm , Should Have Rubber Stopper 1149 K-Files - Size- 15-40 , Length:-25 Mm , Should Have Rubber Stopper 1150 K- Files Size- 45-80, Length:-25 Mm, Should Have Rubber Stopper 1151 K-Files Size- 6, Length :- 21 Mm , Should Have Rubber Stopper. 1152 K-Files Size- 6, Length :- 25 Mm , Should Have Rubber Stopper. 1153 K-Files Size- 8, Length :- 21 Mm , Should Have Rubber Stopper. 1154 K-Files Size- 8, Length :- 25 Mm , Should Have Rubber Stopper. 1155 K-Files Size- 10, Length :- 21 Mm , Should Have Rubber Stopper. 1156 K-Files Size- 10, Length :- 25 Mm , Should Have Rubber Stopper. 1157 Niti Hand Files (21 Mm) Size- 15-40, For Curved Canals 1158 H-Files , Size-15-40 , Length :-21 Mm, Should Have Rubber Stopper 1159 H-Files , Size-45-80, Length :-25 Mm Should Have Rubber Stopper 1160 Matrix Strips,Made From A Thin, Strong, Flexible, Transparent Material Such As Mylar 1161 Barbed Broaches , Made Of Stainless Steel, Can Be Sterilized Length ‰¥ 21 1162 Articulating Paper Strip, Red Colored With Sufficient Thickness Double Side 1163 Articulating Paper Strip, Blue Colored With Sufficient Thickness Double Side 1164 Matrix Band Retainer , No. 1 1165 Matrix Band Retainer , No.8 1166 Matrix Band , No. 1, Toflemire 1167 Matrix Band , No. 8, Toflemire 1168 Paper Point 25 1169 Paper Point 30 1170 Paper Point 35 1171 Mini Plates Isi/ Iso/Ce/Marked. 1172 Arch Bar Length 1Feet Isi/ Iso/Ce/Marked. 1173 Air Rotor Cartridges (Nsk) Supertorque, Standard Head Isi/ Iso/Ce/Marked. 1174 Composite Finishing Kit- Disc Type 1175 Composite Finishing Kit With 12 To 24 Finishing Point Of Different Shapes. The Durable Abbresive Points Are Autoclavabal And Cost Effective, Comprehensive Selection Of Plain For Finishing And Polishing In One Kit, For Fast And Efficient Finishing The Use Of Conjunction With The Composite Polishing Kit, Average Speed 5000 To 12000 Rpm Kit - 1176 Iopa Film Size 30 Mm X 40 Mm 1177 Iopa Film Size 31 Mm X 41Mm 1178 Formocresol Formalin, Cresol Glycerin ,Formocresol Formalin Bp 20% V/V , Cresol Ip 32% V/V , Glycerin Ip Qs 1179 Dental Chair Covering Sterilized Cling Foil Rolls Isi/ Iso/Ce/Marked. 1180 Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) 1181 Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Pale Yellow Powder & Liquid 15Gm Powder & 10 To 13 Liquid 1182 Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Yellow Brown Powder & Liquid 15Gm Powder & 10 To 13 Liquid 1183 Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Dark Grey Powder & Liquid 15Gm Powder & 10 To 13 Liquid 1184 Pit & Fissure Sealant ( 6 Ml Bottle) Solution With High Flouride Releasing, Low Viscocity, High Retention, Rapid Cure & Low Solubility Liquid 6 Ml 1185 Calcium Hydroxide , Paste System Based And Catalyst -Radiopaque, 4 Gm Paste 4 Gm 1186 Zinc Phosphate Cement , 20 Gm Powder And 10 Ml Liquid Powder & Liquid 20 Gm Powder And 10 Ml Liquid 1187 Glass Ionomer Cement- Type-Ix, High Strenth For Posterior Teeth, Chemical Setting Without Shrinkage, Strontium Based, High Flouride Releasing, 12 To 15 Gm Powder And 5 To 10 Gm Liquid Powder & Liquid 12 To 15 Gm Powder & 5 To 10 Ml Liquid 1188 Hybrid Composite Resin For Anteriors (All Shades), High Strength, Long Lasting Wear Resitance, Great Handling Without Stick, 4 Gm Isi/ Iso/Ce/Marked. 4 Gm 1189 Mineral Trioxide Aggregate, 0.5 Gm Isi/ Iso/Ce/Marked. 0.5 G 1190 Flowable Composite 2 Mg Syringe, Flowable Consistancy Thicsotrophic, Low Shrinkage, Radiopaque, Easily Polishability, Should Be Hybrid, Wear Resistance, Syringe Design To Eleminate Bubbles 2 Mg 1191 Niti Rotory Files 4%, 21 Mm (Pkt Of 6) Refill Pack Of(#15,#20,#25,#30,#35,#40) 21 Mm 1192 Niti Rotory Files 4%, 25 Mm (Pkt Of 6) Refill Pack Of (#15,#20,#25,#30,#35,#40) 25 Mm 1193 Niti Rotory Files 6%, 21 Mm (Pkt Of 6) Refill Pack Of( #15,#20,#25,#30,#35,#40) 21 Mm 1194 Niti Rotory Files 6%, 25 Mm (Pkt Of 6) Refill Pack Of( #15,#20,#25,#30,#35,#40) 25 Mm 1195 Crown Cutting Kit, Set Of 14 Burs - 1196 Adhesive Resin Cement (Dual Lock Composite Resin Cement), 4.5 Gm Isi/Iso/Ce Marked Cement 4.5 Gm 1197 Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution 1198 Root Canal Spreader 15-40, 21 Mm Isi/Iso/Ce Marked 1199 Root Canal Spreader 15-40, 25 Mm Isi/Iso/Ce Marked 1200 Gutta Percha Point No. 20, Isi/Iso/Ce Marked 1201 Gutta Percha Point No. 25, Isi/Iso/Ce Marked 1202 Gutta Percha Point No. 30, Isi/Iso/Ce Marked 1203 Gutta Percha Point No. 15-40, Isi/Iso/Ce Marked 1204 Gutta Percha Point No. 45-80, Isi/Iso/Ce Marked 1205 Absorbent Point No.15-40, Isi/Iso/Ce Marked Packet Of 200 1206 Absorbent Point No.45-80, Isi/Iso/Ce Marked Packet Of 200 1207 Stainless Steel Wire 26G. Soft Isi/Iso/Ce Marked 1208 Gates Glidden Drill No.1 1209 Gates Glidden Drill No.2 1210 Gates Glidden Drill No.3 1211 Pillow Cover Cotton Size:48 X 70 Cm, Color - Violet 1212 Pillow Cover Cotton Size:48 X 70 Cm, Color - Indigo 1213 Pillow Cover Cotton Size:48 X 70 Cm, Color - Blue 1214 Pillow Cover Cotton Size:48 X 70 Cm, Color - Green 1215 Pillow Cover Cotton Size:48 X 70 Cm, Color - Yellow 1216 Pillow Cover Cotton Size:48 X 70 Cm, Color - Orange 1217 Pillow Cover Cotton Size:48 X 70 Cm, Color - Peach 1218 Bed Sheet Size-150 X 240 Cm, Color:Violet 1219 Bed Sheet Size-150 X 240 Cm, Color:Indigo 1220 Bed Sheet Size-150 X 240 Cm, Color:Blue 1221 Bed Sheet Size-150 X 240 Cm, Color:Green 1222 Bed Sheet Size-150 X 240 Cm, Color:Yellow 1223 Bed Sheet Size-150 X 240 Cm, Color:Orange 1224 Bed Sheet Size-150 X 240 Cm, Color:Peach 1225 Ot Linen Poplin- Green Color, Size : 90 X 90 1226 Ot Linen Poplin- Green Color, Size : 90 X 140 1227 Ot Linen Poplin- Green Color, Size : 140 X 210 1228 Ot Linen Poplin- Green Color, Size : 90 X 90 (With Oval) 1229 Ot Linen Poplin- Green Color, Size : 90 X 140 (With Circular Hole Of Size 10€ Diameters In Centers Green Color) 1230 Ot Linen Poplin- Green Color, Size : 130 X 180 (With Circular Hole Of Size 10€ Diameters In Centers Green Color) 1231 Ot Linen Cotton White 88X88 Cm. With Hole Size 9 X 10 Cm. In Centre And Should Be Folded And Stitched So There Are No Loose Ends. 1232 Ot Gown Poplin Length 130 X 135 Cms Arm’S Length 58 X 60 Back Open Type With Provision Of Tying With String At Back Arm Should Have Elasting Cuff Or Cord For Tying At Cuff End. The Inside Of Gown Should Be Inter Lock So That There Are No Loose Threads 1233 Patient Dress Kurta Payjama (Striped Blue) Small. Kurta Length 70 X 80 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1234 Patient Dress Kurta Payjama (Striped Blue) Medium. Kurta Length 80 X 90 Cms Arm Length 22X 24 Cms.V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1235 Patient Dress Kurta Payjama (Striped Blue) Large. Kurta Length 100 X 105 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1236 Doctor Dress Kurta Payjama (Blue) Small. Kurta Length 70 X 80 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1237 Doctor Dress Kurta Payjama (Blue) Medium. Kurta Length 80 X 90 Cms Arm Length 22X 24 Cms.V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1238 Doctor Dress Kurta Payjama (Blue) Large. Kurta Length 100 X 105 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1239 Towel 56 X 115 Cms. White Color 1240 Dental Sheet Green Cotton 45 X 45 Cms. 1241 Aprons (Lab Coats ) (Small) Full Size, Full Sleeves 1242 Aprons (Lab Coats) (Medium) Full Size, Full Sleeves 1243 Aprons (Lab Coats) (Large) Full Size, Full Sleeves 1244 Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed 1245 Drape Sheet For Cssd 2 X2 Mtr. Cotton Cloth Grey Color 1246 Kurta, Petticoat Sets Large Size , Green Strip 1247 Glass Lonomer Silver Reinforced Isi/Iso/Ce Marked 1248 Glass Lonomer Luting Cement Isi/Iso/Ce Marked 1249 Rubber Dam Sheet Isi/Iso/Ce Marked 1250 Sterilization Rolls For Packing Instrument 15Cm X 200Mtrs 1251 Collagen Membrane-Sterile Bioresorbable Gtr Collagen Membrane Isi/Iso/Ce Marked 1252 6% Taper Gutta Percha Size 25 1253 6% Taper Gutta Percha Size 30 1254 6% Taper Gutta Percha Size 35 1255 6% Taper Gutta Percha Size 40 1256 4% Taper Gutta Percha Size 25 1257 Esthetic Fiber Post System 1258 Pre Fabricated Metallic Post ( Cemented) 1259 Pre Fabricate Metallic Post (Threaded) 1260 Rubber Base Impression Material Addition Silicone Putty With Compatible Light Body 600-900Ml Putty With 50 Ml Light Per 300Ml Of Putty Isi/Iso/Ce Marked 1261 Retraction Cord (Assorted Size Isi/Iso/Ce Marked 1262 Bone Graft Material For Dental Purpose Isi/Iso/Ce/Marked 1263 Surgical Bur Straight Fissure Carbide 1 Mm Isi/Iso/Ce/Marked 1264 Surgical Bur Straight Fissure Carbide 1.5 Mm Isi/Iso/Ce/Marked 1265 Surgical Bur Straight Fissure Carbide 2 Mm Isi/Iso/Ce/Marked 1266 Resin Cement Isi/Iso/Ce Marked 1267 Preadjusted Edgewise Stainless Steel Brackets Kit Containing Upper & Lower 2Nd Premolar To 2Nd Premolar Bondable Brackets With Upper Triple And Lower Double Weldable Buccaltubes,With Roth And Mbt Prescription And 0.022€And 0.018€ Slot (Leone/American Orth 1268 Ni Ti Preformed Orthodontic Wire Round - 014 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1269 Ni Ti Preformed Orthodontic Wire Round - 016 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1270 Ni Ti Preformed Orthodontic Wire Round - 018 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1271 Ni Ti Preformed Orthodontic Wire Round - 020 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1272 Ni Ti Preformed Orthodontic Wire Rectangular -016X022 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1273 Ni Ti Preformed Orthodontic Wire Rectangular -017X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1274 Ni Ti Preformed Orthodontic Wire Rectangular -019X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1275 Stainless Steel Preformed Orthodontic Wire Round 014 Inch (Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1276 Stainless Steel Preformed Orthodontic Wire Round 016 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1277 Stainless Steel Preformed Orthodontic Wire Round 018 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1278 Stainless Steel Preformed Orthodontic Wire Round 020 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1279 Stainless Steel Preformed Orthodontic Wire Rectangular 016X022 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1280 Stainless Steel Preformed Orthodontic Wire Rectangular 017X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1281 Stainless Steel Preformed Orthodontic Wire Rectangular 019X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1282 Blue Elastic Separators ( Leone/ American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1283 Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Short Types Isi/Iso/Ce Marked 1284 Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Long Types Isi/Iso/Ce Marked 1285 Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Continous Types Isi/Iso/Ce Marked 1286 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Yellow Isi/Iso/Ce Marked 1287 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Blue Isi/Iso/Ce Marked 1288 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Green Isi/Iso/Ce Marked 1289 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Red Isi/Iso/Ce Marked 1290 Colourless O Rings (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1291 Expansion Screw 3 Pin (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1292 Preformed Molar Bands Without Buccal Tubesisi/Iso/Ce Marked 1293 Bioplast Sheets Proprietary Item 2 Mm Thickness Isi/Iso/Ce Marked 1294 Bioplast Sheets Proprietary Item 3 Mm Thickness Isi/Iso/Ce Marked 1295 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 19 Gauge Isi/Iso/Ce Marked 1296 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 20 Gauge Isi/Iso/Ce Marked 1297 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 21 Gauge Isi/Iso/Ce Marked 1298 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 23 Gauge Isi/Iso/Ce Marked 1299 Tma Wire Lengths Rectangular - 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1300 Tma Wire Lengths Rectangular - 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1301 Tma Wires Preformed Rectangular- 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1302 Tma Wires Preformed Rectangular- 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1303 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 6Mm Isi/Iso/Ce Marked 1304 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 7Mm Isi/Iso/Ce Marked 1305 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 8Mm Isi/Iso/Ce Marked 1306 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 10 Mm Isi/Iso/Ce Marked 1307 Forsus Fatigue Resistant Device( 3 M Unitek ), Proprietary Itemisi/Iso/Ce Marked 1308 Powerscope 2 (American Orthodontics Proprietary Item)Isi/Iso/Ce Marked 1309 Etchant 37% Phosphate Acid In Gel Form 2-4 Gm, Isi/Iso/Ce Marked 1310 Loose Preadjusted Edgewise Mbt Bracket 022 Slot Isi/Iso/Ce Marked Per Bracket 1311 Bondable Buccal Tubes Upper And Lower Right And Left 1St Molars .022€ Mbt With Upper Triple And Lower Double Slot (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1312 Bondable Buccal Tubes Upper And Lower Right And Left 2Nd Molars .022€ Mbt (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1313 Ni-Ti Open Coil Spring0 10€X 030 (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marke 1314 Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 9Mm Isi/Iso/Ce Marked 1315 Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 12Mm Isi/Iso/Ce Marked 1316 Eugenol 110 Ml Isi/Iso/Ce Marked 1317 Zinc Oxide Powder 110 Gram Isi/Iso/Ce Marked 1318 Naoci 5.25% Solution Isi/Iso/Ce Marked 1319 Fiber-Reinforced Splinting Material- Bondable Reinforced Ribbon Fiber-Approx. 2Mm Width Isi/Iso/Ce Marked 1320 Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer Isi/Iso/Ce Marked 1321 Air Rotor Spray Isi/Iso/Ce Marked Bottle 1322 Disposable Patient Drape Sheets Size 1X1 Mtrs. 1323 Single Use Syringes 10 Ml With Needle 23 G. X 1€ Length Sterile Isi/Iso/Ce Marked 1324 Single Use Syringes 5 Ml With Needle 23 G. Sterile 1€ Length Isi/Iso/Ce Marked 1325 Single Use Syringes 2 Ml With Needle 23 G. Sterile 1€ Length Isi/Iso/Ce Marked 1326 Single Use Insulin Syringes With Needle Sterile Isi/Iso/Ce Marked 1327 B.P. Blade Size 11 Isi/Iso/Ce Marked 1328 B.P. Blade Size 15 Isi/Iso/Ce Marked 1329 B.P. Blade Size 23 Isi/Iso/Ce Marked 1330 Silk Suture Material (3-0) 1331 N-95 Respirator Mask(Covid) 1332 Ppe Kit(Covid) 1333 Vtm Media(Covid) 1334 Triple Layer Mask(Covid) 1335 Hydroxy Chloroquine Tablet 200 Mg(Covid) 1336 Lysol(5L)(Covid) 1337 Sodium Hypochlorite(5L)(Covid) 1338 Oxygen Cylinder(Covid) 1339 Real Time Pcr Kit(Covid) 1340 Covid19 Igm/Igm Rapid Test (Wondfo Sars-Cov-2 Antibody Test)(Covid) 1341 Dead Body Cover(Covid) 1342 Rapid Screening Kits For Covid-19 Test(Covid) 1343 Denture Spirit-Surgical Spirit With Methyl Salicylate, Diethyl Phthalate And Caster Oil Dentured Alchol, 500 Ml Bottle(Covid) 1344 Disposable Bed Sheet(Covid) 1345 Thermal Scanner(Covid) 1346 Tab Levocetrizine 5 Mg(Covid) 1347 Spun Bond Non-Woven 3 Ply Face Covers(Covid) 1348 Magna Pure 24 Total Na Isolation Kit, Pack Size-96(Covid) 1349 Magna Pure 24 Processing Cartridge, Pack Size-48(Covid) 1350 Magna Pure 24 Tip Ptark (Comes With Pierecing Tools)Pack Size-48(Covid) 1351 Magna Pure Tip 1000 Ul, Pack Size-3840(Covid) 1352 Framestrips With Flat Caps High Profile, Pack Size-120(Covid) 1353 Magna Pure Sealing Foil,Pack Size-100(Covid) 1354 Mplct Na Isolation Kit- Lysis/ Binding Buffer Refill, Pack Size-100Ml(Covid) 1355 Handsanitizer (500 Ml)(Covid) 1356 Framestrip With Flat Caps-Low Profile(Covid) 1357 Magna Pure 96 External Lysis Buffer(Covid) 1358 Light Cycler -480 Multiwell 11 Plate 96(Covid) 1359 Light Cycler 8-Tube Strip Adapter Plate(Covid) 1360 Manual Rna Extraction Kit-50 Test(Covid) 1361 Oseltamivir 75 Mg 1362 Covid Kavachâ„¢ Anti- Sars Cov-2 Igg Antibody Detection Elisa (96 Micro Well Coated Plate 1363 Tocilizumab Injection 400 Mg/20 Ml(Covid) 1364 Standard Q Covid19,Ag Test(Rapid Antigon Test) 1365 Lc Prep Lysi/Bind Buff Dna,Mbp 1366 Ramdesivir Injection 100Mg 1367 Hydroxychlorine Tablet 400 Mg(Covid) 400 Mg 1368 Dexamethasone 6 Mg Tablet(Covid) 6 Mg 1369 Enoxaparin 40 Mg Injection(Covid) 40 Mg 1370 Favipiravir(Covid) 400 Mg 1371 Coronil Kit Coronil Kit Each Contains(80Tab+80Tab+20Ml) 1372 Ayush Kwath Powder 1373 Amphotericin B Powder For Injection 50 Mg Liposomal Complex,Vial Injection Powder 50Mg/Ml, 10Ml Vial 1374 Tocilizumab 80 Mg 1375 Oxygen Regulator With Humidifier Bottle,Rotameter And Key For B And D Type Cylinders 1376 Disposable Ad Syringes 0.5Ml. 1377 Nitrile Gloves(Large Size),Purple,Powder Free,Box Of 100 Pcs 1378 Nitrile Gloves(Medium Size),Purple,Powder Free,Box Of 100 Pcs 1379 Nitrile Gloves(Small Size),Purple,Powder Free,Box Of 100 Pcs 1380 Tablet Posaconazole 100 Mg 1381 Intravenous Immunoglobulin(Ivig) 10 Gm,100 Ml Bottle 1382 Sars-Cov-2 Sequencing Kits Test Kit Kit 1383 Corbevax Vaccine,10 Ml Vial 1384 Zinc Oxide Cream 10% 10 Gm 1385 Zinc Oxide Powder 100 Gm 1386 Zinc Phosphate Cement , Powder And Liquid 1387 Zinc Sulphate Dispersible Tablet 20 Mg 1388 Zinc Sulphate Syrup 60 Ml 1389 Zoledronic Acid Injection 4 Mg 1390 Balloon Tamponade (Standard Size) 1391 Miracle Mix(Standard Size) 1392 Bonding Agent 1393 Endo Files(Standard Size) 1394 Orafill(Standard Size) 1395 Pain Off(Standard Size) 1396 Composite Syringes A1(Standard Size) 1397 Composite Syringes B1(Standard Size) 1398 Lignocaine Spray 1399 Dycal(Standard Size) 1400 Metapex(Standard Size) 1401 Restoration Bonding Agent 1402 Mixing Pad(Standard Size) 1403 Coe-Pack(Standard Size) 1404 Temephos 50% 1 Ltr 1405 Pyrazinamide 500 Mg Tablet 1406 Pyrazinamide 750Mg Tablet 1407 Rifampicin 150 Mg Capsule 1408 Rifampicin 300 Mg Capsule 1409 Rifampicin 450 Mg Capsule 1410 Isoniazid 300 Mg Tab. 1411 Isoniazid 100 Mg Tab. 1412 Ethanbutol 800 Mg Tab. 1413 Ethanbutonl 400 Mg. Tab. 1414 Ethanbutol 100 Mg Tab. 1415 4 Fdc (A) 1416 3 Fdc (A) 1417 Inj. Streptomycetin 0.75 Gm 1418 3 Fdc Ped. (P) 1419 2 Fdc Ped. (P) 1420 Pas Poder 1421 Iec Jel Pack 1422 Tharmocal Box 1423 Falcon Tube 50 Ml 1424 Tab. Pyridoxin 50 Mg 1425 Inj. Kanamicine 18 M 1426 Tab. Cyclocerin 500 Mg 1427 Tab. Cyclocerin 250 Mg 1428 Tab. Ethonamlde 250 Mg 1429 Tab. Uvezolld 1430 Tab. Clofazimine 100 Mg 1431 Tab. Coprpcomycine 1 Mg 1432 Tab. Delamanid 50 Mg 1433 Tab. Moxifloxacin 400 Mg 1434 Multi Drug Urine Screen Kits 1435 Cotton Bandages(1 X 12 Rolls) 10 Cm X 4 Mtrs 1436 Cotton Bandages(1 X 12 Rolls) 15 Cm X 5 Mtrs 1437 Cotton Bandages(1 X 12 Rolls) 5 Cm X 4 Mtrs 1438 Cotton Gauze Cloth(1 X 5 Than) 90 Cm X 18 Mtrs 1439 Cotton Wool Ip 100 Gm 1440 Cotton Wool Ip 500 Gm (Net) 1441 Cotton Wool Ip 500 Gm 1442 Disposable Cap 1443 Disposable Surgical Gloves No. 6.5, Isi Mark 1444 Disposable Surgical Gloves No. 7, Isi Mark 1445 Disposable Surgical Gloves No. 7.5, Isi Mark 1446 Disposable Surgical Gloves No.6 , Isi Mark 1447 Disposable Syringe 20 Ml With Needle, Ribbon Pack 1448 Disposable Syringe 50 Cc With Needle, Ribbon Pack 1449 Disposable Syringes 1 Ml (23G), Ribbon Pack 1450 Disposable Syringes 10 Ml. With Needle, Ribbon Pack 1451 Disposable Syringes 2 Ml, (23G), Ribbon Pack 1452 Disposable Syringes 2 Ml, (24G), Ribbon Pack 1453 Disposable Syringes 5 Ml, (23G), Ribbon Pack, Reuse Preventable 1454 Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 6.5 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) 1455 Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 7 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) 1456 Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 7.5 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) 1457 Disposable Shoe Cover 1458 Disposable Insulin Syringe (31G), Ribbon Pack 1459 Disposable Mask 1460 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle 1461 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle 1462 Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle 1463 Suture Catgut 3-0No. R.B. Needle 1464 Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle 1465 Suture Silk 2-0No. R.B. Needle 1466 Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1467 Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1468 Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1469 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (12 Foils In Each Box) 1470 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (12 Foils In Each Box) 1471 Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1472 Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) 1473 Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (12 Foils In Each Box) 1474 Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1475 Stadiometer 1476 Wooden Stick (Oral Examination) 1477 Bp Appratus 1478 Weighing Machine (Digital) 1479 Acetic Acid 100% 1480 Swab Sticks For Vig Examanation 1481 Torch 1482 Mouth Mirror 1483 Disttled Water 1484 Wooden Tongue Depressor 1485 Mantoux Test 1486 Albumin (5X50Ml) 1487 Alkline Phosphtase 4X24 + 4X6Ml) 1488 Bilirubin Kit 4X60Ml) 1489 Cholestrol Kit 5X30Ml) 1490 Creatinine Kit (4X60M)L 1491 Ggt (5X6.5Ml) 1492 Glucose Kit (5X60Ml) 1493 Hdl Kit (4X30Ml + 4X10Ml) 1494 High Control For Semi Auto (1X5Ml) 1495 Normal Control For Semi Auto (1X5Ml) 1496 Sgot Kit (4X24Ml + 4X6Ml) 1497 Sgpt Kit (4X24Ml + 4X6Ml) 1498 Total Protein (5X50Ml) 1499 Triglycerides Kit (4X24Ml + 4X6Ml) 1500 Urea Kit (4X24Ml + 4X6Ml) 1501 Uric Acid Kit (4X24Ml + 4X6Ml) 1502 Wash Kit (4X50Ml) 1503 Reagent For Fully Automatic Bio-Chemistry Analyser Bs400 Which Must Be In Liquid State Stable Form 1504 Alkaline Phosphate 8X50 / 8X12.5Ml 1505 Amylase 4 X 20 Ml/ 2 X 10 Ml 1506 Bilirubin Total 8X50 / 8X12.5Ml 1507 Bilirubin Direct 8X50 / 8X12.5Ml 1508 Cholestrol 8X50Ml 1509 Crp Fs 1X20 / 1X10Ml 1510 Ck - Nack 4 X 20 Ml/ 2 X 10 Ml 1511 Cpk - Mb 4 X 20 Ml/ 2 X 10 Ml 1512 Creatinine 8X50 / 8X12.5Ml 1513 D-Dimer 2X12Ml + 1X8Ml 1514 Ferritin 2X20 / 1X10Ml 1515 Glucose 8X50/8X12.5Ml 1516 Hdl 4X20 / 2X10Ml 1517 Hba1C 2X15 / 1X10 / 1X5Ml 1518 Hba1C 3X20/ 2X10 / 1X10Ml 1519 Hemolyzing Solution 500 Ml 1520 Iron Tibc 4X20 / 2X10 1521 Ldh 8X50Ml + 8X12.5Ml 1522 Ldl 4X20 / 2X10Ml 1523 Lipase 4X20 / 2X10Ml 1524 Ra Factor 2X20 / 1X8Ml 1525 Acetec Acid 5% 1526 Tablet Chlorine 1527 Capillary Tubes 1528 Card For Haemo Spot 1529 Centrifuge Tube Stand 15 Ml(10*2) 1530 Centrifuge Tube Stand 50 Ml(15*2) 1531 Conical Flask 500 Ml 1532 Coplin Jars 1533 Covid Elisa Antigen Kit (Icmr Approved) 1534 Crp 50 Test Kit (Qualitative) 1535 Cryo Box With Lid 1536 Cryo Vials 2 Ml 1537 Cup For Bs400 Chemistry Analyzer 1538 Diamond Marking Pencils 1539 Disposable 3 Ply Mask 1540 Disposable Alcohol Swab 1541 Disposable Cap 1542 Disposable Esr Pipette 1543 Disposable Esr Tube (Westergen Method) 1544 Disposable Gown 1545 Disposable Shoe Cover 1546 Distilled Double Dionized Water 5 Ltr 1547 Distilled Triple Dionized Water 5 Ltr 1548 Distilled Dionized Water 5 Ltr 1549 Drums Tube 1550 Ecg Jelly/Usg Jelly 1551 Edta Vial (Non Vacuum) 1552 Edta Vial (Vacuum) 1553 Eppen Drop Vial ( Mct ) 1554 Esr Black Vial (Non Vacuum) 1555 Esr Black Vial (Vacuum) 1556 Esr Stand 1557 Face Shield 1558 Falcon Tube Rack 1559 Falcon Tube (All Size) 1560 Filter Paper 1561 Filter Tip 100 Micro Litre (1*960) 1562 Filter Tip 20 Micro Litre (1*960) 1563 Filter Tip 10 Micro Litre (1*960) 1564 Filter Tip 200 Micro Litre (1*960) 1565 Filter Tip 5 Micro Litre (1*960) 1566 Floride Vial (Non Vacuum) 1567 Floride Vial (Vacuum) 1568 Gel Iec Pack 1569 Glass Bottel Round 1570 Glass Cover Slip 22 Mm 1571 Glass Pipette 10Ml 1572 Glass Pipette 2Ml 1573 Glass Pipette 5Ml 1574 Glass Slide 1575 Glucostix 50 Sticks 1576 Hand Sanitizer 5 Ltr (Ip Base) 1577 Hb Pipette 1578 Hb Tube 1579 Hbsag Card 1580 Hcv Rapid Card 1581 Hiv Rapid Card 1582 Insulated Sample Transportation Box 1583 Lancet (Auto Destroyable/Safety Lancet) 1584 Lancet (Twisted Round) 1585 Leucoreduction Filter 1586 Malaria Antigen Card 1587 Mct Vials 1.5Ml 1588 Mct Vials 2.0Ml 1589 Measuring Cylender 20Ml 1590 Measuring Cylender 100Ml 1591 Measuring Cylender 500Ml 1592 Measuring Cylender 1000Ml 1593 Microscope Cover Glass 22 X 40 Mm 1594 Multistix 1595 N/10 Hcl 500Ml 1596 Parafilm Tape 1597 Pastuer Pipette 1598 Ph Paper 5.0 To 7.5 1599 Plain Vial (Non Vacuum) 1600 Plain Vial (Vacuum) 1601 Ppe Kit (Citra & Drda Approved) 1602 Pregnancy Cards 1603 Ra Factor 50 Test Kits 1604 Reversible Rack Mct 1605 Rubber Teat For Pipette 1606 Slide Storage Rack 1607 Slide Storage Tray Pvc 1608 Sodium Citrate Vials Non Vaccum 1609 Sodium Citrate Vials Vaccum 1610 Sodium Hypochloride 5 % 5 Ltr 1611 Sst Vials Non Vaccum 1612 Sst Vials Vaccum 1613 Steel Rack For Test Tube 48 Hole 1614 Sterile Swab Stick 1615 Sterlum 500Ml 1616 Stickers For Slide (Per Piece) 1617 Test Tube Glass 12*100 1618 Test Tube Glass 12*75 1619 Test Tube Glass 15*150 1620 Test Tube Glass 25*150 1621 Test Tube Stand 1X 10 Slots 1622 Test Tube 1X 30 Slots 1623 Thermocol Box 1624 Thermal Paper Roll 1625 Tissue Paper Roll 20 Meter 1626 Tourniquate 1627 Sample Cup With Label (3 Screw, Sterile)/ Sputum Cup 1628 Uristix 100 Strips 1629 Vaccutainer 1630 Vaccutainer Needle 1631 Vtm Swab Stick (Standard Size) 1632 Washing Brush . For Test Tube (Standard Size) 1633 Widal Kit (Slide Method) 1634 Wipes 1*280 Pc Lab Grade 1635 Yellow Tips 1X1000 Nos 1636 Zip Lock Pouch For 1 Ltr 1637 Anti-D Igg 10 Ml 1638 Anti-D Igm 10 Ml 1639 Copper Sulphate Powder 500Gm 1640 Dpx Mount 1641 Ethanol Absolute 1642 Fouchet Reagent 1643 Giemsa Stain 125 Ml 1644 Glacial Acetic Acid 1645 H & E Stain (Haematoxillin Stain) 1646 J.S.B 1 Stain 1647 J.S.B 2 Stain 1648 Lieshmen Powder 25 Gm 1649 Lugal Iodine 125 Ml 1650 Manual Rna Extraction Kit 50 Test (Icmr Approved) 1651 Mathenol 2.5 Ltrs 1652 Naoh Sodium Hydroxide 1653 Oil Immersion 25Ml 1654 Rapid Pap Stain Kit 1655 Rapid Test Kit Igg, Igm, Ns1 For Dengue 1656 Rtpcr Kits 96 Test For Covid-19 (Icmr Approved) 1657 Siprit 1658 Sodium Chloride 1659 Sodium Dehydrogen Orthophosphate 1660 Sodium Hydrogen Orthophosphate 1661 Sodium Hypochloride 10% 1662 Sulphar Powder 500 Gm 1663 T3 Elisa (96 Test) 1664 T4 Elisa (96 Test) 1665 Tsh Elisa (96 Test) 1666 Xylene 1667 Anti Ab 1668 Anti D ( Igg+ Igm) 1669 Anti Human Sera/ Coombs Sera 1670 Blood Grouping Plate 1671 Bovine Albumin 1672 Single Blood Bag 350 Ml 1673 Triple Blood Bag 450 Ml 1674 Double Blood Bag 350 Ml(Sagm) 1675 Double Blood Bag 350 Ml 1676 H.I.V Elisa 4Th Generation (96 Test) 1677 Hb Strips 1678 Hbsag Elisa 4Th Generation (96 Test) 1679 Hcv Elisa 4Th Generation (96 Test) 1680 Quadraple Blood Bags 450Ml 1681 Single Blood Bag 350Ml 1682 Vdrl Card 1683 Absolute Alcohol 95% (500 Ml) 1684 Acetone (500Ml) 1685 Hiv Tridot Rapid Cards 1686 Biological Indicator 1687 Bunsen Burner 1688 C.L.E.D Agar 500Gm 1689 Carbol Fuchsin Powder (25 Gm) 1690 Carbol Fuchsin (125 Ml) 1691 Carbolic Acid 500Ml 1692 Chemical Indicator 1693 Concave Slide 1694 Conical Flask 500Ml 1695 Crystal Violet (125 Ml) 1696 Cyto Brush With Spatula (100 Piece) 1697 Glucose Broath 1698 Gram Iodine Solution (125 Ml) 1699 Haematoxylene Stain 1700 Hydrogen Peroxide 3% (500Ml) 1701 Indicator Tape For Steam Autoclave Process Verification 1702 KovacS Indole Reagent (100 Ml) 1703 Lactose Monohydrate (500 Gm) 1704 Leucoreduction Filter 1705 Liquid Broath 1706 Mac Conkey Agar 500Gm 1707 Mac Conkey Broth Double Strength 500Gm 1708 Methylene Blue 25 Gram (Powder) 1709 Motility Test Medium 1710 Mr Vp Medium 500Gm 1711 Muller Hinton Agar 500Gm 1712 Ph Strips 1713 Sulphuric Acid 98.9% (500 Ml) 1714 Xld Agar 500 Gm) 1715 Xylose Lysine (100 Gm) 1716 Young Broath Culture 1717 Alp Kit 1718 Aso Kit 1719 Capillary Tubes For Ct(Pkts) 1720 Cover Slip(Pkt.) Large(Pkts.) 1721 Cover Slip Small (Pkts.) 1722 Crp Kit 1723 Diamond Pencil 1724 Edta Vacutainer 1725 Esr Tube 1726 Filter Paper For Bt(Pkts) 1727 Formalin (Ltrs.) 1728 Glass Slide 1729 Glucostrips 1730 GramS Stain 1731 Hemoglobin Strips/Hemoque 1732 Ketac-Molar 1733 LeishmanS Stain 1734 Lens Cleaner 1735 Levolin Respules 1736 LugolS Iodine 1737 Mgg Giemsa Stain 1738 Pap Smear Spectulla & Cyto Brush 1739 Ph Strips(Pkts.) 1740 Plain Vacutainer 1741 Plastic Container For Urine 1742 Pm Kits 1743 Ra Kit 1744 Rapid Pep Stain Kit 1745 S.Albumin Kit 1746 S.Calcium Kit 1747 S.Protein 1748 Semen Diluting Fluid (Bottles) 1749 Sugar Kit 1750 Suture (10.0) F 3719 Nylon 1751 Toluidene Blue(500Ml.) 1752 Torniquet 1753 Tsh Card 1754 Widal Kit 1755 Zn Stain Kit 1756 Micro Tips Large 1757 Orthotoluedine Solution 1758 Uristic 1759 Lq080 10 Ml Cooked M Medium (10 Ml X 25) 1760 Sterile Individual Packed Cotton Swabs 1761 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-10Ul 1762 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-20Ul 1763 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-200Ul 1764 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 100-1000Ul 1765 Skirted Pcr Plate (96 Wells) 1766 Sterile Transparent Sealant For Pcr Plate (96 Well) 1767 Pcr Kits For Covid 19 Testing Compatible With Biorad Pcr 1768 Mac Conkey Both Purple Single Strength W/ Bcp Media M 083 1769 Mac Conkey Both Purple Double Strength W/ Bcp Media M/96 1770 Elisa Ns1 Dengue Kit (96 Test) 1771 Auromine - O (Per Gm) Powder 1772 Broom Stick Stirrer(Pkt 100) 1773 Heparin Lithimum Tube 1774 Pernament Marker Pen Black 1775 Methanol 5Ltr 1776 Zip Lock Bag 20X25 Cm 1777 Hydrochloric Acid (Mw36.46 ) 1778 Slide Box (100 Slide Per Box) 1779 Biohazard Symbol (Red) 1780 Phenol Cristal 1781 Cello Tape (5 Cm) 1782 Potossium Permagnent (Kmno4) Cristal 50 Gm 1783 Spirit Lamp 1784 Spirit Alochloic 1785 Squize Bottle (Small) 1786 Squize Bottle (Big) 1787 Ruber Band 1788 Temp. Humidity Meter 1789 Weighinj Scale Degital 1790 Perafilm 1791 Brosile Zar 5 Ltr 1792 Brosile Zar 3 Ltr 1793 Brosile Zar 500 Ml 1794 Mac Conkey Broth Purple Single Strength W/ Bcp (Hi Media M083 1(500Gm.) 1795 Mac Conkey Broth Purple Double Strength W/Bcp (Hi Media M 796 1(500 Gm.) 1796 Ria- Tubes 1797 Plastic Tube With Cap 2 Ml 1798 Plastic Tube For Calcium Test 1799 Bp Apparatus Digital 1800 Bp Apparatus Marcury 1801 Weighinj Scale For Blood Unit 1802 Stethoscope 1803 Dengue Ns1 Rapid Test Card 1804 Dengue Igm+Igg Combo Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
32.
Housing Urban and Rular Development #11170747 Technical Bid
Tender for Hiring Of 5 Nos. 60 Hp Sewage Submersible Pumps Suitable For Operation On 3-Phase, 50 Hz Ac Power Supply, Including Installation At Site At Depths Up To 5 Metres, Complete With Motor, Starter, And Capable Of Passing Solids Of Minimum 100 Mm Size, Along With All Required Accessories Such As Power Cabling, Control Panels, Connections, Interconnections, Etc., Including Complete Installation, Testing, Commissioning And Maintenance As Required, And Execution Of The Work In Accordance With The Directions Of The Engineer-In-Charge. , Hiring Of 250 Kva Dg Set Without Diesel, But Including All Other Consumables Such As Lubricants, Grease, Mobil Oil, Etc., Complete With Making All Necessary Connections And Interconnections, And Including Installation, Testing, Commissioning And Maintenance As Required, All In Accordance With The Directions Of The Engineer-In-Charge. , Hiring Of 150 Kva Dg Set Without Diesel, But Including All Other Consumables Such As Lubricants, Grease, Mobil Oil, Etc., Complete With Making All Necessary Connections And Interconnections, And Including Installation, Testing, Commissioning And Maintenance As Required, All In Accordance With The Directions Of The Engineer-In-Charge. , Operation Of Three (03) Sewage Submersible Pump Sets By Deployment Of Required Manpower, Including Supply And Handling Of Pol (Diesel) For Operation Of Dg Sets. The Scope Includes Cartage, Safe Storage, And Filling Of Diesel In Tanks, As Well As All Associated Activities Necessary For Smooth And Continuous Operation, Complete In All Respects, As Per Site Requirements And Directions Of The Engineer-In-Charge. , Operation Of Two (02) Sewage Submersible Pump Sets By Deployment Of Required Manpower, Including Supply And Handling Of Pol (Diesel) For Operation Of Dg Sets. The Scope Includes Cartage, Safe Storage, And Filling Of Diesel In Tanks, As Well As All Associated Activities Necessary For Smooth And Continuous Operation, Complete In All Respects, As Per Site Requirements And Directions Of The Engineer-In-Charge. , Providing Mild Steel (Ms) Pipes Up To 400 M Length, Fabricated/Manufactured From Ms Plates Of Steel Grade Fe-410 Conforming To Is 3589:2001 (With Latest Amendments), Or From Hr Coils Of Equivalent Grade, On Hiring Basis. The Pipes Shall Be Coated With One Coat Of Approved Primer And Finished With Anti-Corrosive Bituminous Paint, Including Proper Surface Preparation, Complete In All Respects, As Per Relevant Is Specifications And As Directed By The Engineer-In-Charge. Note: The Pipes Are To Supplied On Hiring Basis. A) 300Mm Internal Nominal Dia., 6Mm Thick. , Providing Mild Steel (Ms) Pipes Up To 1900 M Length, Fabricated/Manufactured From Ms Plates Of Steel Grade Fe-410 Conforming To Is 3589:2001 (With Latest Amendments), Or From Hr Coils Of Equivalent Grade, On Hiring Basis. The Pipes Shall Be Coated With One Coat Of Approved Primer And Finished With Anti-Corrosive Bituminous Paint, Including Proper Surface Preparation, Complete In All Respects, As Per Relevant Is Specifications And As Directed By The Engineer-In-Charge. Note: The Pipes Are To Supplied On Hiring Basis. A) 500Mm Internal Nominal Dia., 6Mm Thick. , Laying And Jointing Of Mild Steel (Ms) Pipes Of 300 Mm Diameter For Lengths Up To 400 M, In The Required Alignment, Levels, And Slope, Including All Necessary Fittings And Fixtures Such As Tees, Bends, Reducers, Air Valves, Reflux (Non-Return) Valves, And Other Appurtenances. The Scope Includes Making Connections At The Outfall Point, Testing, And Ensuring Proper Functioning Of The Pipeline System. The Item Also Includes Dismantling And Removal Of The Ms Pipeline After Completion Of The Work, Including Handling And Stacking, Complete In All Respects, As Per Site Requirements And Directions Of The Engineer-In-Charge. , Laying And Jointing Of Mild Steel (Ms) Pipes Of 500 Mm Diameter For Lengths Up To 1900 M, In The Required Alignment, Levels, And Slope, Including All Necessary Fittings And Fixtures Such As Tees, Bends, Reducers, Air Valves, Reflux (Non-Return) Valves, And Other Appurtenances. The Scope Includes Making Connections At The Outfall Point, Testing, And Ensuring Proper Functioning Of The Pipeline System. The Item Also Includes Dismantling And Removal Of The Ms Pipeline After Completion Of The Work, Including Handling And Stacking, Complete In All Respects, As Per Site Requirements And Directions Of The Engineer-In-Charge. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. A) Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. A) Nominal Concrete 1:4:8 Or Leaner Mix (Including Equivalent Design Mix) , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Up To A Lead Of 1 Kilometre, As Per Direction Of Engineer-In-Charge , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge. All Kinds Of Soil , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , Supplying Cement Bags Filled With Jamuna Sand, Including Filling, Proper Stitching Of Bag Mouths, Handling, Transportation, Stacking, And Placing In Position At Site, Complete In All Respects, As Per Site Requirements And Directions Of The Engineer-In-Charge. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level 1:1%:3 (1 Cement: 1% Coarse Sand (Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Total = Rs.1,67,03,644.05 , Gst Correction Factor @0.973 = Rs.1.62.52.645.66 , Add Cost Index @ 4.99 = Rs.6,54,981.62 , Note:- The Total Duration Of The Work Shall Be 150 Days, Which Includes 30 Days For Setting Up The Pumping Stations, Installation Of Pipeline Arrangements, And Commissioning Of The System From The Date Of Award Of Work. This Shall Be Followed By 90 Days Of Operation And Maintenance As Per The Directions Of The Engineer-In-Charge. The Final 30 Days Shall Be Utilized For Dismantling The Pumping Stations And Pipeline Arrangements, And For Restoring The Dismantled Road And Site To Its Original Condition.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
33.
Power #11168103 Price Bid
Tender for Repairing/Replacement Of Damaged Protection Relays At 18 Nos. 33/11 Kv Substations Under Electricity Distribution Division, Hapur, Including Thorough Inspection, Testing, Calibration, Wiring, And Commissioning Of Relays, And Carrying Out Repair And Maintenance Of 33 Kv Vcbs, Ct/Pt Units, Control Panels, And Associated Equipment; The Work Shall Include Fault Diagnosis, Servicing, Tightening, Replacement Of Minor Defective Components, Cleaning, Oiling/Greasing (Wherever Required), Restoration Of Control Wiring, Testing And Proper Functioning Of All Protection And Control Systems, And All Allied Works Required For Satisfactory Operation Of The Substation. The Rate Shall Be Inclusive Of All Labour, Tools & Plants (T&P), Testing Equipment, Consumables, Minor Materials, Handling, And All Incidental Charges Necessary To Complete The Work In All Respects As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Carriage/Transportation Of Departmental Materials From Electricity Store Center Hapur To Work Site Under The Jurisdiction Of Edc-Hapur, 33/11 Kv Substation Approx. Distance Upto 50 Km. Including Loading, Unloading, Stacking, And Safe Handling At All Stages Of Transit; The Work Shall Be Carried Out For All Types Of Materials With Due Care To Prevent Damage And Shall Include All Labour, Vehicles, Fuel, Tools & Plants (T&P), And All Incidental Charges Required To Complete The Work In All Respects. , 33 Kv Line Isolator 800A , 33 Kv Current Transformer 400/200/1 Or 200/100/1 , 11 Kv Potential Transformer , Acsr / Dog Panthor Conductor , Eraction And Fixing And Making Connection Of 33 Kv Line Isolator 33 Kv (800 Amp.) (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , Erection, Fixing And Replacement Of Defective 33 Kv Current Transformer (Ct) Of Ratio 400/200/1 Including Dismantling Of The Faulty Ct, Supply (If Required), Installation, Alignment, Connection, Testing, Commissioning, And Making The System Operational, Complete In All Respects With All Necessary Labour, Tools & Tackles, And Safety Measures As Per Standard Specifications. , Providing, Fixing And Replacement Of Defective 33 Kv Panel O/C + E/F Idmt Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards And Respo Norms, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective 33 Kv Panel Master Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective 33 Kv Panel Auxiliary Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Closing Coil As Per Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Tripping Coil As Per Pvvnl Standards, Including Dismantling Of The Faulty Unit, Installation Of New Tripping Coil, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Main Contact Block Of Breaker, Including Dismantling Of The Faulty Contact Block, Installation Of New Contact Block, Alignment, Connections, Testing, Commissioning And Making The Breaker Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Tnc (Trip-Neutral-Close) Switch As Per Pvvnl Standards, Including Dismantling Of The Faulty Switch, Installation Of New Tnc Switch, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Control Cable From Panel To Vcb/Ct Chamber Using 2C & 4C × 2.5 Sq.Mm Armoured Cable, Including Dismantling And Removal Of Existing Cable, Supply And Laying Of New Cable, Dressing, Termination With Suitable Lugs And Glands, Ferruling, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Vcb Spring Charging Motor Of Appropriate Make And Rating As Per Pvvnl Standards, Including Dismantling Of The Defective Motor, Installation Of New Motor, Alignment, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective/Burnt Mcb Of Appropriate Make And Rating As Per Pvvnl Standards, Including Dismantling Of The Faulty Mcb, Installation Of New Mcb, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective/Burnt Auxiliary Switch Of Appropriate Rating As Per Pvvnl Standards, Including Dismantling Of The Faulty Switch, Installation Of New Auxiliary Switch, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Anti-Pumping Relay Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation Of New Relay, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Led Indicator As Per Pvvnl Standards, Including Dismantling Of The Faulty Indicator, Installation Of New Led Indicator, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Ammeter, Including Dismantling Of The Faulty Meter, Supply And Installation Of New Ammeter Of Appropriate Rating, Connections, Calibration (If Required), Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Voltmeter, Including Dismantling Of The Faulty Meter, Supply And Installation Of New Voltmeter Of Appropriate Rating, Connections, Calibration (If Required), Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Local/Remote Selector Switch, Including Dismantling Of The Faulty Switch, Supply And Installation Of New Switch Of Appropriate Rating, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Buzzer, Including Dismantling Of The Faulty Unit, Supply And Installation Of New Buzzer Of Appropriate Rating, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Servicing And Maintenance Of Electrical And Mechanical Systems For Proper Opening, Closing And Tripping Of 33 Kv Breakers, Including Servicing Of 33 Kv Panels For Correct Operation Of Tripping, Alarm And Indication Systems, Providing And Rectification Of Internal Wiring With Suitable Control Cables, Lugs, Ferrules Of Appropriate Rating And Colour Coding, And Ensuring Proper Interconnection Between Panels, Dc Charger, 33 Kv Breakers, Cts, Pts And Associated Equipment Such As Power Transformer Oti, Wti, Oil Level Indicator, Buchholz Relay Etc.; Including Maintenance Of Lighting Arrangement In Switchyard And Control Room And Execution Of Other Related Works Of 33/11 Kv Substation, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures., With A Warranty Period Of Six Months, And Proper Marking Of Repair Date On Panel And Entry In Maintenance Register After Rectification Of Fault. , Providing, Fixing And Replacement Of Damaged Heavy-Duty Pg Clamp In Switchyard As Per Pvvnl Standards, Including Dismantling Of The Faulty Clamp, Installation Of New Pg Clamp, Tightening, Proper Connection, Testing And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Damaged Isolator Jaw, Complete As Per Pvvnl Standards, Including Dismantling Of The Defective Jaw, Installation Of New Isolator Jaw, Alignment, Tightening, Proper Contact Setting, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
34.
Power #11168102 Price Bid
Tender for Repairing/Replacement Of Damaged Protection Relays At 19 Nos. 33/11 Kv Substations Under Electricity Distribution Division, Pilkhuwa, Including Thorough Inspection, Testing, Calibration, Wiring, And Commissioning Of Relays, And Carrying Out Repair And Maintenance Of 33 Kv Vcbs, Ct/Pt Units, Control Panels, And Associated Equipment; The Work Shall Include Fault Diagnosis, Servicing, Tightening, Replacement Of Minor Defective Components, Cleaning, Oiling/Greasing (Wherever Required), Restoration Of Control Wiring, Testing And Proper Functioning Of All Protection And Control Systems, And All Allied Works Required For Satisfactory Operation Of The Substation. The Rate Shall Be Inclusive Of All Labour, Tools & Plants (T&P), Testing Equipment, Consumables, Minor Materials, Handling, And All Incidental Charges Necessary To Complete The Work In All Respects As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Carriage/Transportation Of Departmental Materials From Electricity Store Center Hapur To Work Site Under The Jurisdiction Of Edc-Hapur, 33/11 Kv Substation Approx. Distance Upto 50 Km. Including Loading, Unloading, Stacking, And Safe Handling At All Stages Of Transit; The Work Shall Be Carried Out For All Types Of Materials With Due Care To Prevent Damage And Shall Include All Labour, Vehicles, Fuel, Tools & Plants (T&P), And All Incidental Charges Required To Complete The Work In All Respects. , 33 Kv Line Isolator 800A , 33 Kv Current Transformer 400/200/1 Or 200/100/1 , 11 Kv Potential Transformer , Acsr / Dog Panthor Conductor , Eraction And Fixing And Making Connection Of 33 Kv Line Isolator 33 Kv (800 Amp.) (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , Erection, Fixing And Replacement Of Defective 33 Kv Current Transformer (Ct) Of Ratio 400/200/1 Including Dismantling Of The Faulty Ct, Supply (If Required), Installation, Alignment, Connection, Testing, Commissioning, And Making The System Operational, Complete In All Respects With All Necessary Labour, Tools & Tackles, And Safety Measures As Per Standard Specifications. , Providing, Fixing And Replacement Of Defective 33 Kv Panel O/C + E/F Idmt Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards And Respo Norms, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective 33 Kv Panel Master Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective 33 Kv Panel Auxiliary Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Closing Coil As Per Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Tripping Coil As Per Pvvnl Standards, Including Dismantling Of The Faulty Unit, Installation Of New Tripping Coil, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Main Contact Block Of Breaker, Including Dismantling Of The Faulty Contact Block, Installation Of New Contact Block, Alignment, Connections, Testing, Commissioning And Making The Breaker Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Tnc (Trip-Neutral-Close) Switch As Per Pvvnl Standards, Including Dismantling Of The Faulty Switch, Installation Of New Tnc Switch, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Control Cable From Panel To Vcb/Ct Chamber Using 2C & 4C × 2.5 Sq.Mm Armoured Cable, Including Dismantling And Removal Of Existing Cable, Supply And Laying Of New Cable, Dressing, Termination With Suitable Lugs And Glands, Ferruling, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Vcb Spring Charging Motor Of Appropriate Make And Rating As Per Pvvnl Standards, Including Dismantling Of The Defective Motor, Installation Of New Motor, Alignment, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective/Burnt Mcb Of Appropriate Make And Rating As Per Pvvnl Standards, Including Dismantling Of The Faulty Mcb, Installation Of New Mcb, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective/Burnt Auxiliary Switch Of Appropriate Rating As Per Pvvnl Standards, Including Dismantling Of The Faulty Switch, Installation Of New Auxiliary Switch, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Anti-Pumping Relay Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation Of New Relay, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Led Indicator As Per Pvvnl Standards, Including Dismantling Of The Faulty Indicator, Installation Of New Led Indicator, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Ammeter, Including Dismantling Of The Faulty Meter, Supply And Installation Of New Ammeter Of Appropriate Rating, Connections, Calibration (If Required), Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Voltmeter, Including Dismantling Of The Faulty Meter, Supply And Installation Of New Voltmeter Of Appropriate Rating, Connections, Calibration (If Required), Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Local/Remote Selector Switch, Including Dismantling Of The Faulty Switch, Supply And Installation Of New Switch Of Appropriate Rating, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Buzzer, Including Dismantling Of The Faulty Unit, Supply And Installation Of New Buzzer Of Appropriate Rating, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Servicing And Maintenance Of Electrical And Mechanical Systems For Proper Opening, Closing And Tripping Of 33 Kv Breakers, Including Servicing Of 33 Kv Panels For Correct Operation Of Tripping, Alarm And Indication Systems, Providing And Rectification Of Internal Wiring With Suitable Control Cables, Lugs, Ferrules Of Appropriate Rating And Colour Coding, And Ensuring Proper Interconnection Between Panels, Dc Charger, 33 Kv Breakers, Cts, Pts And Associated Equipment Such As Power Transformer Oti, Wti, Oil Level Indicator, Buchholz Relay Etc.; Including Maintenance Of Lighting Arrangement In Switchyard And Control Room And Execution Of Other Related Works Of 33/11 Kv Substation, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures., With A Warranty Period Of Six Months, And Proper Marking Of Repair Date On Panel And Entry In Maintenance Register After Rectification Of Fault. , Providing, Fixing And Replacement Of Damaged Heavy-Duty Pg Clamp In Switchyard As Per Pvvnl Standards, Including Dismantling Of The Faulty Clamp, Installation Of New Pg Clamp, Tightening, Proper Connection, Testing And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Damaged Isolator Jaw, Complete As Per Pvvnl Standards, Including Dismantling Of The Defective Jaw, Installation Of New Isolator Jaw, Alignment, Tightening, Proper Contact Setting, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
35.
Power #11168101 Price Bid
Tender for Repairing/Replacement Of Damaged Protection Relays At 17 Nos. 33/11 Kv Substations Under Electricity Distribution Division, Garhmukteshwar, Including Thorough Inspection, Testing, Calibration, Wiring, And Commissioning Of Relays, And Carrying Out Repair And Maintenance Of 33 Kv Vcbs, Ct/Pt Units, Control Panels, And Associated Equipment; The Work Shall Include Fault Diagnosis, Servicing, Tightening, Replacement Of Minor Defective Components, Cleaning, Oiling/Greasing (Wherever Required), Restoration Of Control Wiring, Testing And Proper Functioning Of All Protection And Control Systems, And All Allied Works Required For Satisfactory Operation Of The Substation. The Rate Shall Be Inclusive Of All Labour, Tools & Plants (T&P), Testing Equipment, Consumables, Minor Materials, Handling, And All Incidental Charges Necessary To Complete The Work In All Respects As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Carriage/Transportation Of Departmental Materials From Electricity Store Center Hapur To Work Site Under The Jurisdiction Of Edc-Hapur, 33/11 Kv Substation Approx. Distance Upto 50 Km. Including Loading, Unloading, Stacking, And Safe Handling At All Stages Of Transit; The Work Shall Be Carried Out For All Types Of Materials With Due Care To Prevent Damage And Shall Include All Labour, Vehicles, Fuel, Tools & Plants (T&P), And All Incidental Charges Required To Complete The Work In All Respects. , 33 Kv Line Isolator 800A , 33 Kv Current Transformer 400/200/1 Or 200/100/1 , 11 Kv Potential Transformer , Acsr / Dog Panthor Conductor , Eraction And Fixing And Making Connection Of 33 Kv Line Isolator 33 Kv (800 Amp.) (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , Erection, Fixing And Replacement Of Defective 33 Kv Current Transformer (Ct) Of Ratio 400/200/1 Including Dismantling Of The Faulty Ct, Supply (If Required), Installation, Alignment, Connection, Testing, Commissioning, And Making The System Operational, Complete In All Respects With All Necessary Labour, Tools & Tackles, And Safety Measures As Per Standard Specifications. , Providing, Fixing And Replacement Of Defective 33 Kv Panel O/C + E/F Idmt Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards And Respo Norms, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective 33 Kv Panel Master Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective 33 Kv Panel Auxiliary Relay With Suitable Retrofitting Arrangement Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Closing Coil As Per Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation, Wiring, Testing, Commissioning And Making The System Fully Operational As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Tripping Coil As Per Pvvnl Standards, Including Dismantling Of The Faulty Unit, Installation Of New Tripping Coil, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Main Contact Block Of Breaker, Including Dismantling Of The Faulty Contact Block, Installation Of New Contact Block, Alignment, Connections, Testing, Commissioning And Making The Breaker Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Tnc (Trip-Neutral-Close) Switch As Per Pvvnl Standards, Including Dismantling Of The Faulty Switch, Installation Of New Tnc Switch, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Control Cable From Panel To Vcb/Ct Chamber Using 2C & 4C × 2.5 Sq.Mm Armoured Cable, Including Dismantling And Removal Of Existing Cable, Supply And Laying Of New Cable, Dressing, Termination With Suitable Lugs And Glands, Ferruling, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Vcb Spring Charging Motor Of Appropriate Make And Rating As Per Pvvnl Standards, Including Dismantling Of The Defective Motor, Installation Of New Motor, Alignment, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective/Burnt Mcb Of Appropriate Make And Rating As Per Pvvnl Standards, Including Dismantling Of The Faulty Mcb, Installation Of New Mcb, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective/Burnt Auxiliary Switch Of Appropriate Rating As Per Pvvnl Standards, Including Dismantling Of The Faulty Switch, Installation Of New Auxiliary Switch, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Anti-Pumping Relay Of Approved Makes Such As Ashida, Schneider, C&S Or Equivalent, Conforming To Pvvnl Standards, Including Dismantling Of The Existing Relay, Installation Of New Relay, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Led Indicator As Per Pvvnl Standards, Including Dismantling Of The Faulty Indicator, Installation Of New Led Indicator, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Ammeter, Including Dismantling Of The Faulty Meter, Supply And Installation Of New Ammeter Of Appropriate Rating, Connections, Calibration (If Required), Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Voltmeter, Including Dismantling Of The Faulty Meter, Supply And Installation Of New Voltmeter Of Appropriate Rating, Connections, Calibration (If Required), Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Local/Remote Selector Switch, Including Dismantling Of The Faulty Switch, Supply And Installation Of New Switch Of Appropriate Rating, Wiring, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Defective Buzzer, Including Dismantling Of The Faulty Unit, Supply And Installation Of New Buzzer Of Appropriate Rating, Connections, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Servicing And Maintenance Of Electrical And Mechanical Systems For Proper Opening, Closing And Tripping Of 33 Kv Breakers, Including Servicing Of 33 Kv Panels For Correct Operation Of Tripping, Alarm And Indication Systems, Providing And Rectification Of Internal Wiring With Suitable Control Cables, Lugs, Ferrules Of Appropriate Rating And Colour Coding, And Ensuring Proper Interconnection Between Panels, Dc Charger, 33 Kv Breakers, Cts, Pts And Associated Equipment Such As Power Transformer Oti, Wti, Oil Level Indicator, Buchholz Relay Etc.; Including Maintenance Of Lighting Arrangement In Switchyard And Control Room And Execution Of Other Related Works Of 33/11 Kv Substation, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures., With A Warranty Period Of Six Months, And Proper Marking Of Repair Date On Panel And Entry In Maintenance Register After Rectification Of Fault. , Providing, Fixing And Replacement Of Damaged Heavy-Duty Pg Clamp In Switchyard As Per Pvvnl Standards, Including Dismantling Of The Faulty Clamp, Installation Of New Pg Clamp, Tightening, Proper Connection, Testing And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures. , Providing, Fixing And Replacement Of Damaged Isolator Jaw, Complete As Per Pvvnl Standards, Including Dismantling Of The Defective Jaw, Installation Of New Isolator Jaw, Alignment, Tightening, Proper Contact Setting, Testing, Commissioning And Making The System Fully Operational, As Per Directions Of The Site In-Charge, Complete In All Respects With Supply Of All Required Nuts, Bolts, Clamps, Lugs, Connectors Etc., Along With All Labour, Tools & Plants (T&P) And Safety Measures.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
36.
Power #11168099 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , St Pole 13 M- Is 410 Sp- 72 , Stay Set 16X1800 , Acsr Dog Conductor , Acsr Weasel Conductor , A.B.Cab. L.T. (3X95)+ (1X70)+ (1X16)Sq.Mm , A.B.Cab. L.T. (3X120) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Earth Rod 2540X20 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Composite Polymer Pin Insulator , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Composite Polymer Pin Insulator , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Ms Channel 100X50 Mm , 33 Kv Cross-Arm 100X50 Mm V-Type , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Gi Wire 5 Mm/6 Swg , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Xlpe Cable Box 3X300 , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , 11 Kv Cable Box O/D 3X185sq.Mm , M.S. Angle 75X75x6 Mm , M.S. Angle 65X65x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , Stay Set 16X1800 , Stay Set Gi 20X1800 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , Ms Channel 100X50 Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Cross-Arm 100X50 Mm V-Type , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Disc Fitting 45 Kn (T&C) , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Composite Polymer Pin Insulator , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , Ms Angle 75X75x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection & Fixing Of Single Pole Structure Of Following Pole Of 11 Kv Line Along With X-Arm And Pin Insulator After Digging Of Suitable Pits Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , St Pole 13 Mtrs , Erection Of 11Kv Double-Pole Structure After Digging Of Suitable Pits On Following Pole With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , Erection Of 33Kv Double-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Tri-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Four-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection & Fixing Of 33Kv St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Grouting Of Following St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Plain Cement Concrete Pole 8.5 , Plain Cement Concrete Pole 11 Mtr. Long , Stp 13 Mtrs Long , Construction Of T/F Plinth Suitable For 160/250/400 Kva T/F (Size 2X2x1.5 Mtr) After Digging Of Earth And Construction With 14 Bag Cement, Fine Sand, Coarse.Sand, Brick Ballast, 1St Class Bricks 6000, Stone Ballast (40Mm), Ms Channel 125X65mm (54 Kg), Ms Twisted Bar 20 Mm (50 Kg) & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100/250 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , 250 Kva Transformer On Plinth , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Providing And Installation Of Maintenance-Free Chemical Earthing System For 250 Kva Distribution Transformer, Comprising Of Supply And Erection Of Approved Make Chemical Earth Electrode (Gi/Copper Bonded, Of Standard Length And Diameter) Installed In Drilled/Bored Hole Of Required Depth In All Types Of Soil, Including Backfilling With Highly Conductive Earthing Compound (Bfc/Graphite Based) To Achieve Low And Stable Earth Resistance; Providing Separate And Distinct Earthing For Transformer Body, Neutral And Lightning Arrester (If Applicable) Using Required Number Of Chemical Electrodes Interconnected Where Necessary; Construction Of Earth Pit Chamber With Brick Masonry, Plastering And Heavy Duty Ci/Rcc Cover With Provision For Watering/Inspection; Providing And Laying Of Gi Strip (E.G., 50×6 Mm) Or Suitable Copper Strip From Transformer Body, Neutral Point And La To Respective Earth Electrodes, Including All Connections With Nuts, Bolts, Washers, Lugs, Clamps And Anti-Corrosive Treatment; Testing Of Earth Resistance To Ensure Values Within Permissible Limits As Per Is/Respo Standards And Ensuring Long-Term Stability Without Frequent Maintenance; The Scope Includes Cost Of All Materials Such As Chemical Electrodes, Backfill Compound, Gi/Copper Strips, Bricks, Cement, Sand, Covers, Water, Etc., And All Labour, Drilling, Installation, Refilling, Carriage, Loading/Unloading, Handling, Testing, Commissioning And All Tools & Plants (T&P) Required For Complete And Satisfactory Execution Of Work As Per Standard Specifications And Direction Of Engineer-In-Charge. , Construction Of Safety Fencing (Ms) Size 3X3x2 Mtr. For Dist. Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle/T-Iron To Be Fitted On Vertical Posts. Pickets (If Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 65X65x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Providing, Installing, Testing And Commissioning Of Tailless Unit Suitable For 250 Kva Distribution Transformer, Including Dismantling Of Existing Tail Connections (If Any), Supply And Fixing Of Required Lt/Ht Connectors, Busbar Arrangements, Insulated Sleeves, And Necessary Termination Accessories; Complete Modification Of Transformer Lt Side To Tailless Configuration Ensuring Proper Phase Segregation, Insulation And Mechanical Strength; Including Providing And Fixing Of Suitable Size Aluminium/Copper Lugs, Glands, Ferrules, Heat Shrink Sleeves, Pvc Insulation Tape, Nut-Bolts, Washers And All Jointing Materials As Required; Making Proper Cable Terminations, Dressing And Clamping Of Cables With Gi Clamps; Providing And Ensuring Effective Earthing Of The Tailless Unit With Gi Strip/Wire And Connecting To Existing Earthing System; Including Painting Of Modified Portion With Suitable Anti-Corrosive Paint; Complete Testing For Continuity, Insulation Resistance And Proper Load Transfer; The Work Shall Be Carried Out As Per Relevant Is Standards, Respo/Departmental Specifications And As Directed By Engineer-In-Charge; The Rate Shall Include Cost Of All Materials, Labour, Tools & Plants (T&P), Handling, Loading/Unloading, Transportation, And All Incidental Works Required To Complete The Job In All Respects. , Providing, Laying, Jointing And Commissioning Of 140/200 Mm Dia (Od) Pn-4, Pe-80 Grade Uv Stabilized Hdpe Pipe In 6.0 Mtr Standard Length By Trenchless (Hdd/Drilling) Method For Underground Cable Protection, Including Excavation Of Suitable Size Launching And Receiving Pits, Alignment And Preparation Of Bore Path, Drilling, Reaming And Insertion/Pulling Of Hdpe Pipe, Jointing By Butt Fusion/Electrofusion With All Necessary Fittings Such As Couplers, Bends And End Caps, Ensuring Proper Alignment And Leak-Proof Joints; Including Providing And Laying Of Warning Tape, Route Markers And Identification System; Complete With All Required Tools & Plants (T&P) Such As Hdd Machine, Drilling Machine, Compressor, Generator, Welding Machine, Including All Consumables, Loading/Unloading, Handling And Safe Stacking At Site; Including Dewatering (If Required), Traffic Control, Barricading And Safety Measures; Also Including Restoration Of Road, Footpath, Drain Or Any Other Surface Under Row (Right Of Way) Conditions To Original Condition And Disposal Of Surplus Earth/Muck; Complete In All Respects As Per Relevant Is Standards, Respo/Departmental Norms And Direction Of Engineer-In-Charge, With All Material, Labour, T&P, Transportation And Incidental Charges Included In The Rate. (Rate Will Be Charge As Per Actual Length Of Work) , 200 Mm Dia For 33 Kv Line , 140 Mm Dia For 11 Kv Line , Laying Of Following Cable Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge.(Rate Will Be Charge As Per Actual Length Of Work) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Manually Digging Excavation Of Trench Of Size 0.50 M Width × 1.00 M Depth In All Types Of Soil Including Dressing, Levelling And Disposal Of Surplus Excavated Earth Within Specified Lead As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Supplying And Laying Of Brick Masonry (Class Designated) In Cement Mortar For Side Protection, Providing And Filling Of Sand Cushioning At Bottom And Around The Laid Cable, Followed By Laying Of Plain Cement Concrete (Plain Cement Concrete) Of Required Grade For Base And Protective Covering Over Trench; Thereafter, Placing And Proper Alignment Of Xlpe Cable Within The Complete Trench, And Covering The Trench With Brick/Cc Slab Protection Including Backfilling With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; The Scope Of Work Includes Cost Of All Labour, Materials (Bricks, Sand, Cement, Aggregates, Water Etc.), Handling, Loading/Unloading, Carriage, And All Tools & Plants (T&P) Required For Excavation, Laying And Finishing Works, With All Safety Precautions, As Per Standard Specifications And Directions Of Site In-Charge. (The Firm Will Be Fully Responsible For This Work And Taking Necessary Permission), As Per Direction Of Site Incharge (Rate Will Be Charge As Per Actual Length Of Work). , Laying And Installation Of 11 Kv Grade, 3 Core × 185 Sq.Mm Xlpe Insulated, Armoured Aluminium Conductor Cable In Underground Trench In Double Circuit Formation, Including Careful Handling, Dressing And Alignment Of Cable Along The Route As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Laying Of Cable Over Prepared Sand Bed, Maintaining Proper Spacing Between Circuits, And Ensuring Identification And Phase Marking; Providing Extra Length Of Cable At Both Ends In Loop Formation For Future Jointing/Termination (Spare Cable To Be Left In Loop Shape At Each End) As Specified; Covering Of Cable With Sand Cushioning, Protective Bricks/Tiles/Cc Slabs And Backfilling Of Trench With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; Including Supply Of All Consumables Such As Sand, Bricks, Cable Markers, Route Indicators, Etc., And All Labour, Loading/Unloading, Carriage, Handling Charges, Testing Prior To Commissioning, And All Tools & Plants (T&P) Required For Safe And Proper Execution Of Work As Per Standard Specifications And Site Instructions. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Dog Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying And Stringing Of Following Lt Aerial Bunched Cable (Abc) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Lt Aerial Bunched Cable (Abc) (3×95 + 1×70 + 1×16 Sq.Mm) , Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 4Mm/ 8 Swg , G.I. Wire 5Mm/ 6 Swg , Grouting & Fixing Of Stay Set (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Stay Set (16X1800) , Stay Set Gi (20X1800) , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Dead & Clamp , Suspension Clamp , F-Bracket With Clamp , Cross Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Fuse Set Complete On 25/63/100 Kva Transformer In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad 300X300x75 Of Approved Quality And Specified Size At Pole/Support Locations, Including Excavation Of Suitable Size Pit, Preparation Of Base, Dressing, Leveling, And Proper Placement In Line And Level As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge, Including Refilling, Ramming And Consolidation To Ensure Stability; The Scope Of Work Includes Cost Of All Labour, Loading/Unloading, Carriage, Alignment And All Incidental Works Required For Complete Execution, And All Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable M.S. Clamp, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site, And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Barbed Wire Of Approved Quality And Specification In Position, Stretched And Secured On Poles/Structures With Suitable Binding Wire, Staples, Clamps Or Other Approved Means, Maintaining Proper Tension, Alignment And Height As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing, Tightening And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Stay Insulator Of Approved Make, Type And Rating In Stay Set Assembly, Including Proper Placement Between Stay Wire Lengths, Making Necessary Connections, Tightening And Ensuring Correct Alignment And Insulation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of I-Bolt Of Approved Size And Quality For Guarding Angle, Complete With Nuts, Bolts, Washers And Necessary Accessories, Including Drilling Of Holes In Angle/Pole As Required, Proper Insertion, Fitting, Tightening And Ensuring Correct Alignment And Rigidity As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Number Plate Of Approved Size, Design And Material With Proper Painting/Printing Of Identification Number And Lettering, To Be Securely Mounted On Pole/Structure At Suitable Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fixing With Suitable Clamps, Nuts, Bolts Or Binding Wire As Required, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Necessary For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Draw Out Fuse Set Of Approved Make And Rating, Complete With All Standard Accessories, Mounted On Pole/Structure With Suitable Clamps, Nuts, Bolts And Connectors, Including Proper Alignment, Tightening And Making Necessary Electrical Connections For Safe And Reliable Operation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Erection, Testing And Commissioning And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment, Tackles And Testing Instruments Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Smc Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable Clamps, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Paint And Carrying Out Painting Of Pole With Approved Quality Paint System, Including Thorough Surface Preparation By Cleaning, Scraping, Wire Brushing And Removal Of Rust, Dirt And Loose Materials, Applying Primer Coat Where Required And Finishing With Two Or More Coats Of Approved Paint Of Specified Shade, Including Marking/Numbering If Directed, Complete In All Respects As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage Of Materials To Site And All Incidental Works Necessary For Satisfactory Completion, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Construction Of Meter Room Of Internal Size 8× 8× 10 Height, Including Setting Out, Excavation Of Foundation In All Types Of Soil, Dressing And Disposal Of Surplus Earth Within Specified Lead; Providing And Laying Plain Cement Concrete Of Required Grade For Foundation Base, Followed By Construction Of Brick Masonry In Cement Mortar Of Approved Class For Foundation And Superstructure Walls Of Required Thickness, Including All Leads And Lifts; Providing Reinforced Cement Concrete Lintel And Roof Slab (Solid Slab) Of Required Thickness Using M-20 Grade Concrete With Centering, Shuttering, Vibration And Curing Complete, Including Reinforcement Steel As Per Design; Providing Internal And External Plastering In Cement Mortar Of Required Thickness, Smooth Finishing, And Curing; Providing Flooring With Cement Concrete Or Ips Finish, Including Base Preparation And Finishing; Supplying And Fixing Of Ms/Steel Door With Frame, Including Holdfasts, Hinges, Locking Arrangement And Painting; Providing Ventilators With Ms Grill, Including Fixing; Complete Internal And External Painting/Whitewashing With Approved Quality Paint; Providing Necessary Provisions For Meter Installation Such As Cable Entry Points, Sleeves, Earthing Arrangement, Foundation Bolts And Fixtures; The Scope Includes Cost Of All Materials Such As Bricks, Cement, Sand, Aggregates, Steel, Doors, Grills, Paint, Water, Etc., And All Labour, Tools & Plants (T&P), Scaffolding, Curing, Carriage, Loading/Unloading, Handling And All Incidental Works Required For Complete Construction As Per Standard Specifications And Direction Of Engineer-In-Charge. , Laying Of Power/Control Cable Of Specified Size In Trench/Duct/On Surface Along Approved Route, Including Excavation Of Trench, Sand Cushioning, Proper Dressing, Alignment, Clamping, Identification Tagging, Protective Covering With Bricks/Tiles (Where Required), Backfilling, Ramming, Leveling, And Disposal Of Surplus Earth; Including Handling, Shifting, Straightening, And Pulling Of Cable With Due Care To Avoid Damage And Maintain Required Bending Radius; Complete In All Respects As Per Standard Specifications And Direction Of Engineer-In-Charge, All Materials, Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
37.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
42.
Power #11131078 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , 11 Kv completion Poly. Disc Insulator 45 Kn , Stay Set 16X1800 , M.S. Angle 65X65x6 Mm , Acsr Dog Conductor , A.B.Cab. L.T. (3X120)+ (1X95)+(1X16) Sq.Mm , Earth Rod 2540X20 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , D.O Fuse Set 11 Kv , Acsr Weasel Conductor , Ms Channel 100X50 Mm , 11 Kv Tpmo , Lt Abc 3X50+1X35+1X16 Sq.Mm , G.I. Wire 6 Swg , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable H.T. Xlpe 3X120 Sq.Mm , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , Ms Channel 100X50 Mm , 11 Kv Composite Polymer Pin Insulator , Lt Abc 3X50+1X35+1X16 Sq.Mm , Disc Fitting 45 Kn (T&C) , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection Of 11 Mtr Double Pole Structure For 11 Kv Line Including Excavation Of Suitable Size Pits, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulators With Pins, Disc Insulators With Complete Fittings, Etc., Strictly As Per Respo Drawings/Standard Norms; Providing And Fixing Of All Necessary Clamps Made Of M.S. Flat 50×6 Mm With Suitable Nuts & Bolts, Stone Pad, Jumpering, Alignment, Tightening And All Allied Works; The Scope Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Erection And Fixing Of Single Pole Structure For Lt Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Grouting Of St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Erection And Fixing Of 11 Kv D.O. Fuse Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Fuse Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Erection And Fixing Of 11 Kv Tpmo Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Tpmo Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Overhead 11 Kv Ht Xlpe Cable (3×120 Sq.Mm) On St/Pcc Poles, Including Proper Hanging And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site, And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Trenchless/Drilling Method For Laying Of Underground 11 Kv Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm Underground Through Hdpe Pipe, Including Pulling, Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm , 11 Kv Ht Xlpe Cable Of Size 3×120 Sq.Mm , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 6 Swg , G.I. Wire 4Mm/ 8 Swg , Grouting & Fixing Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , F-Clamp , Holding Clamp With Nut Bolt , Dead & Clamp , Lt Clamp , X Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Insulators Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Box Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Set Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of J Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Weasel Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Installation Of Maintenance-Free, Multifaceted, Corrosion-Resistant Chemical Earthing Electrode Of Size 80 Mm Dia × 3000 Mm Length, Complete With 50 Kg Backfill Compound And All Required Accessories For Body/Neutral Earthing Of Transformers, Including Providing And Fixing Of M.S. Earth Strip For Connection (The Strip To Be Properly Welded To The Earthing Electrode And Neutral Support), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Excavation, Installation, Welding, Connection, Testing, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Jumpering Of Lt/Ht Lines For Proper Energization, Including Cutting, Dressing, Binding And Fixing Of Jumpers With Suitable Connectors/Clamps, Ensuring Proper Electrical Continuity And Safety, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
43.
Power #11126741 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Drain Line Chocking Rectification Of Ahu /Pump Gland Housing Up To Size Of 50 Nb For Details Refer Boq Item No 1 In Sow And 01 Bid Quantity Is Equal To .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Cleaning Of Ventilation Grill Along With Supply Of Gi Rivets For Details Refer Boq Item No 2 In Sow And 01 Bid Quantity Is Equal To 300 Nos.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Cleaning Of Ventilation Grill Along With Supply Of Self Thread Screw For Details Refer Boq Item No 3 In Sow And 01 Bid Quantity Is Equal To .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Duct/ Small Articles Fabrication With Gi Sheet Of Point 8 Mm Thickness And 1200 Mm X 2500 Mm Size For Details Refer Boq Item No 4 In Sow And 01 Bid Quan.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Repair Of Air Leak/Small Crack In Gi Duct For Details Refer Boq Item No 5 In Sow And 01 Bid Quantity Is Equal To 50 Nos; As Per Scope Of Work And Atc , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Preventive Maintenance Of Air Handling Unit Ahu/Fan/Blower With Belt Drive Having Motor Rating Upto 15Kw For Details Refer Boq Item No6 In Sow And 01 Bi.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Air Handling Unit Ahu/Fan/Blower With Belt Drive Having Motor Rating Upto 15Kw For Details Refer Boq Item No7 In Sow And 01 Bid Quantity.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Preventive Maintenance Of Fan/Pump With Rigid Coupling Having Motor Rating Upto 15Kw For Details Refer Boq Item No8 In Sow And 01 Bid Quantity Is Equal .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Fan/Pump With Rigid Coupling Having Motor Rating Upto 1Kw For Details Refer Boq Item No9 In Sow And 01Bid Quantity Is Equal To 10Nos; As .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Cleaning Of Cooling Coil Fins Of Fm Vault Cooler/Pump Room Cooler/Pc Cooling Coil For Details Refer Boq Item No10 In Sow And 01 Bid Quantity Is Equal To.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Preventive Maintenance Of Fan With Belt Drive Having Motor Rating Above 15Kw & Up To 30 Kw For Details Refer Boq Item No11 In Sow And 01 Bid Quantity Is.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Fan With Belt Drive Having Motor Rating Above 15Kw & Up To 30Kw For Details Refer Boq Item No12 In Sow And 01 Bid Quantity Is Equal To 5N.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Preventive Maintenance Of Fan With Rigid Coupling Having Motor Rating Above 15Kw & Up To 30Kw For Details Refer Boq Item No13 In Sow And 01 Bid Quantity.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Fan With Rigid Coupling Having Motor Rating Above 15Kw & Up To 30Kw For Details Refer Boq Item No14 In Sow And 01 Bid Quantity Is Equal T.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Belt Replacement, Pulley Alignment And Tension Adjustment Of Fan Motor/Ahu Blower-Motor Having Motor Of Rating Upto 30Kw/Damper-Actuator For Details Ref.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; De-Coupling, Alignment And Coupling Of Fan Motor/Pump Motor Having Motor Of Rating Upto 30Kw For Details Refer Boq Item No 16 In Sow And 01 Bid Quantity.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Preventive Maintenance Of Fan Motor Having Motor Rating Of 132Kw For Details Refer Boq Item No17 In Sow And 01 Bid Quantity Is Equal To 8Nos; As Per Sco.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Fan Or Overhauling Of Spare Motor And Replacement Of Motor Rating Of 132Kw For Details Refer Boq Item No18 In Sow And 01 Bid Quantity Is .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Belt Replacement Pulley Alignment And Tension Adjustment Of Fan Motor Having Motor Of Rating 132Kw For Details Refer Boq Item No19 In Sow And 01 Bid Qua.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Air Washer Pumps Suction Strainer Element Cleaning/Replacement Or Valves Gland Packing Replacement For Details Refer Boq Item No20 In Sow And 01 Bid Qua.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Minor Leak Rectification By Tightening In Pump Gland/ Valve Gland/ Flange Joint/ Other Joints Or U Clamp Installation For Details Refer Boq Item No21 In.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement Of P-Seal Side/Top In Dryer3 Rotary Bed Up To Length Of 5 Meter For Details Refer Boq Item No22 In Sow And 01 Bid Quantity Is Equal To 4Nos;.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Inspection & Pm Checks/Rectification Of Jamming/Problem Related With Free Rotation Of Dryer 3 Rotary Bed Mechanism For Details Refer Boq Item No 23 In S.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Maintenance Of Rb Ventilation Doors And Replacement Of Door Seal For Details Refer Boq Item No24 In Sow And 01 Bid Quantity Is Equal To 30Nos; As Per Sc.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Pneumatic Linear/ Quarter Turn Rotary Actuators For Details Refer Boq Item No 25 In Sow And 01 Bid Quantity Is Equal To 100Inch Dia; As P.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Diaphragm Valve/ Butterfly Damper Without Pneumatic Actuator/Manual Butterfly Damper With Gear Box/Gravity Damper For Details Refer Boq I.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Gasket Replacement And Torque Tightening Of Flange Joint For Details Refer Boq Item No27 In Sow And 01 Bid Quantity Is Equal To 300Inch-Dia; As Per Scop.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Pm Checks Of Fusible Bulb Operated Fire Damper/ Flapper Type Damper Up To Size One Sqm For Details Refer Boq Item No28 In Sow And 01 Bid Quantity Is Equ.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Flapper Type Manual/Fire/Air Operated Dampers Of Cross Section Size Below Point25 Sqm Along With Supply Of Neoprene Rubber Foam Gasket Fo.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Flapper Type Manual/Fire/Air Operated Dampers Of Cross Section Size Above Point25 Sqm For Details Refer Boq Item No30 In Sow And 01 Bid Q.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Repair/Replacement Of Polythene Sheet In Vapour Barrier Window Of Maximum Size Of 4 Sqm For Details Refer Boq Item No31 In Sow And 01 Bid Quantity Is Eq.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Blanking And Normalization Of Spectacle Flanges For Testing Of Rb Isolation Damper/ Valves Along With Supply Of Industrial Gasket For Details Refer Boq .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Removal And Installation Of Pulley Of Ahu Blower/ Ahu Motor/Fan/Motor Having Motor Rating Up To 25 Kw For Details Refer Boq Item No 33 In So.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Removal And Installation Of Coupling Of Pump/Fan And Motor And Alignment Having Motor Rating Up To 30 Kw For Details Refer Boq Item No34 In .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Removal And Installation Of Pulley Of Fan/Motor Having Motor Rating From 25Kw To 150Kw For Details Refer Boq Item No35 In Sow And 01 Bid Qua.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Opening And Box Up Of Man- Hole Cover Of Tank/Equipment Housing/Plenum For Details Refer Boq Item No 36 In Sow And 01 Bid Quantity Is Equal To 20Nos; As .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement Of Hepa Filter With New Filter Of Size 602 Mm X 602 Mm X 292 Mm For Details Refer Boq Item No37 In Sow And 01 Bid Quantity Is Equal To 500No.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement Of Hdpe/Felt Filters With New Filters For Details Refer Boq Item No 38 In Sow And 01 Bid Quantity Is Equal To 200Nos; As Per Scope Of Work A.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Removal Cleaning And Installation Of Hdpe/Felt Filters For Details Refer Boq Item No39 In Sow And 01 Bid Quantity Is Equal To 1500Nos; As Per Scope Of W.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement Of Rubber Liner Of Butterfly Damper For Details Refer Boq Item No40 In Sow And 01 Bid Quantity Is Equal To 50Inch-Dia; As Per Scope Of Work .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement Of Pre-Filter Hdpe/Hepa In Pccd/Scrp/Pcfpb System Along With Removal And Installation Of Spool Piece In Upstream Of Pre Filter For Details R.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement Of Combined Hepa Cum Charcoal Filter Along With Supply Of Synthetic Rubber Adhesive Sr 998 In Pack Of Maximum 1Kg For Details Refer Boq Item.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Lubrication Of Fan / Motor/Pump/Damper For Details Refer Boq Item No43 In Sow And 01 Bid Quantity Is Equal To 150Nos; As Per Scope Of Work And Atc , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Drain Line Chocking Rectification Of Ahu/Pump Gland Housing For Details Refer Boq Item No44 In Sow And 01 Bid Quantity Is Equal To 150Nos; As Per Scope .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Cleaning Of Ventilation Grill Along With Supply Of Gi Rivets For Grills 8Nos Per Grill For Details Refer Boq Item No45 In Sow And 01 Bid Qua.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Replacement/Cleaning Of Ventilation Grill Point 25 Sqm Along With Supply Of Self Thread Screw For Grills For Details Refer Boq Item No46 In Sow And 01 B.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Duct/ Small Articles Fabrication With Gi Sheet Of Point 8 Mm Thickness And 1200 Mm X 2500 Mm Size Including Removal Of Old/Damaged Duct Erection And In.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Supply Of Gi Sheet Of Thickness Point8 Mm Cold Insulation Material Expanded Polystyrene Thermocol Slabs Of Thickness 50 Mm Insulation Aluminium Cladding.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Repair Of Air Leak/Small Crack In Gi Duct For Details Refer Boq Item No49 In Sow And 01 Bid Quantity Is Equal To 30Nos; As Per Scope Of Work And Atc , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Preventive Maintenance Of Air Handling Unit Ahu/Fan/Blower With Belt Drive Having Motor Rating Upto 15Kw For Details Refer Boq Item No50 In Sow And 01 B.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site 5 And 6; Overhauling Of Air Handling Unit Ahu/Fan/Blower With Belt
Contract Date: Ref. Documents Contract Value : 1.99 Crore
Boards / Undertakings / PSU No of Bidders 6
44.
Defence #11119298 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Hiring Of Services For Erection Of Metallic Cladding At Gaurav Stambh Naval Dockyard Mumbai; Hiring Of Services For Erection Of Metallic Cladding At Gaurav Stambh Naval .. - Executing Precision Ground Interface Preparation At Specified Locations On Top Of Existing Underground Watertank, Including Setting Out, Controlled Sub-Surface Material Removal, And Base Conditioning To Specified Alignment Tolerances Without Any Disturbance To Structure Of Underground Water Tank.Cope Includes Base Consolidation, Face Stabilization, Subsurface Condition Management, And Handling Of Displaced Material, Ensuring Readiness For Integration With Prefabricated Vertical Frame Systems. , Providing And Installing Auxiliary Prefabricated Subframe System Configured For Installation Of Heritage Stone Facade Along And Base Panels,Including Fabrication, Alignment, And Fixing To Achieve Required Load Transfer, Wind Load And Dimensional Stability. , Supply And Installation Of Base Panels On Both Faces Of The Support Framework, Including Precision Fixing Using Appropriate Anchors Fastners, Joint Alignment, And Surface Continuity To Achieve A Balanced Double-Sided Enclosure. The Assembly Should Be In Level And Seamlessly Fixed Suitable For Fixing Of Heritage Stone Facade As Per Facade Panel Oem Requirement. , Supply And Installation Of Heritage Stone Finished Facade System Using Modular Cladding On Exposed Faces Of Base Panels, Including Surface Preparation, Alignment, And Secure Fixing To Achieve Uniform Finish And Edge Definition, Using Adhesives And Other Hardware As Per Oem Specifications.
Contract Date: Ref. Documents Contract Value : 21.89 Lakh
Government Departments No of Bidders 5
Maharashtra View Result →
45.
Housing Urban and Rular Development #11118160 AOC
Tender For Modular Operation Theatre Items At Sadar Hospital, Jamtara At Jamtara For The Year-2025-26 , Wall And Ceiling Cladding (Approved Makes: Jindal/Tata/Essar) Prefabricated Wall & Ceiling Prefabbicated Modular Operating Theater Using Ppgi Puf Panel (Both Wall & Ceiling) Providing Of Pre-Fabricated Modular Operation Theater With Ppgi Puf Pannel Filled With Puf Of 40 Kg/Cubic Meter (40D) Having Required Mechanical Strength And Better Thermal Insulation Which Saves Energy Construction The Panels Joints Are Properly Cam Locked & Revisited Which Provides A Seamless Sub- Structure Which Again Sanded To A Smooth Finish. Approx. Thickness For Wall 50 Mm, Raiser 40 Mm. And Ceiling 30Mm. , Laminar Air Flow System Supply Installation Testing And Commissioning Of Ceiling Filtration System 2400 X 2400 Mm. The Ceiling Filtration System Shall Be 2.40 Meters X 2.40 Meters And Will Be Integrated With The Adjacent False Ceiling. The Ceiling Shall Be Constructed With A Plenum Box Supplied With Conditioned Air From The Central System Via 8 Nos.Hepa Filters (European Norm En1822:2009; Class H14; Dop 99.97-99.9999% Efficincy For 0.3 Micron Particles) With Pressure Drop Of 300 Pascals At Its Nominal Flow Rates (Supplied With The Plenum), Mounted On The Exit From The Supply Ducting. , Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Weled With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Hermetically Sealed Sliding Door System Fabrication Supply, Installation, Testing & Commissioning Of Sliding Type Hermetically Sealed Ot Door Having High Density Partical Board Cores, High Pressure Laminate Face On Both Sides, Viewing Window 300 X 300Mm. Size:1800 X 2100 Mm.(Wx H). Automatice Doors: Provided With Radar Switch- 2 Nos., Foot Switch Nos. And Photocell Sensors (Anti Crush Feature) & As Per Tech. Specs.Attached. Automatice Doors Size:(1800 X 2100 Mm.) , Peripheral Lights Supply Installation And Commissioning Of 42W Bottom Opening Room Fixture With Ip 65, Led Make Should Be Nichia/Seoul5 Sdcm, Own Make Bis Certified Islocated Driver, Flicker Free, Class2 Selv Driver, Operating Temperature:-100C To 450C Operating Voltage Range:140-270V, Surge Protecction 3.5 Kv, High Effciency Driver:80-85%, Low Voltage Cut Off Below 130V, Output Short Circuit Protction, Fixture Made Up Of Ms Power Coated White After Phosphochromate Treatment Provided As Standard With Sheet Thickness Of 1.2 Mm. Diffuser Of High Impact Polycarbonate Opal Diffuser With Thickness 1.5Mm For Glare Freeuniform Light Distribution, Power Coating: 60Microns, Lamp Source: High Efficiency Long Life Led Package In Integral Module To Ensure Better Uniformity, Average Life L70b50: 50000 Hours,Thd10%,95, System Efficacy 95-100 Lm/W, Cri80, Ip65, Ik05 Impact Rating, Dimension Will Be , Surgeon Control Panel Supply, Installation, Testing & Commissioning Of Operation Theatre Control Panel Membrane Type: Time Day Clock Time Elapse Clock General And Rgb Lighting System Conntrol (Peripheral Lights And Plenum Lights With Dimming) Medical Gas Alarm Panel 5 Gas- Low, Normal And High Pressure With Sequencing As Per Htm 02 01 Hand Free Telephone Set With Speaker Temperature & Humidity Indicator With Controller Hepa Filter Status Module Room Pressure Indicator/ Differential Pressure Indicator , X-Ray View Screen Supply Installation, Testing & Commissioning Of Twin Plate Led Xray Viewing Screen: Size:940 X 640 X 50 Mm. Approx With Viewing Area, Two Plate X-Ray View Screen (120W), Led Based Technology With Colour Temperature6000k And Lamp Life50,000 Hrs And Brightness In Excess Of 4000 Lux. , Writing White Board Supplying & Fixing Of Sturdy Writing Operating List Board: Made Of Ceramic Surface Having Magnetic Properties And Should Be Flushed To The Wall Of The Operating Room Size 940Mmx 640Mmx 50Mm , Surgeon Pendant Providing & Fixing Of Ceiling Mounted Single Arm Pendant Systems For Surgeon: The Weight Carrying Capacity Of The Arm Should Not Be Less Than 180 Kgs. Load. There Should Be 5 Or 6 Nos. Equipment Loading Shelves. Double Column Of 1000Mm. Single Arm Pivot Range Minimum 900 Mm. Or Above. The Brake (Electromagnetic) Supplied With Indian Origin Multipin 6/16 Annual Periodical Maintenance Electrical Switch+Socket-5Nos. It Should Have 2 No. Rj 45 Data Socket. It Should Have Provision For 06 Gas Outlet Points 2 Oxygen 1 Sa7 1Co2 1 Vacuum Capable Of 340 Degrees Of Rotation. Medical Gas Terminal Units Shall Be Provded By The Mgps Vendor And Shall Be Installed In The Pendant. Usfda , Anesthesia Pendant Ceiling Mounted Rigid Pendant Systems For Anaesthesia: Single Arm Motorized Type Pendants Made Of Aluminum, Powder Coate Dimensions: Double Vertical Column 1200 Mm. Vertical Lift:600 Mm. Horizontal Arms- Total 1000 Mm. Pendant Should Be Prepiped Provided With 5 Nos. Medical Gas Outlets. Outlets Shall Be Connected To Dual Circuit Being Provisioned For All Ozygen 2 Outlets. Nitrous Oxide 1 Outlets Vacuum 1 Outlets. Medical Air 1 Outlets Agss 1 Outlet Colour Coded High Pressure Tubing For Each Gas With Nist Connectors At Ceiling Provided With Prewired 10 Nos 6/16 Amps Sockets And Two Data Sockets Rj45 Instrument Loanding Capacity 180 Kgs. Shelves: Two With Handle And Two Rail Each With Capacity Of 40 Kgs. Drawers One With Handle And Twe Rails Load Capacity 40 Kgs. Swiveling Stainless Steel Vertical Pole , Air Conditioning System: Ahu Supply, Installation & Commissioning Of Air Handling Unit Make: Vts (8.5Tr) (Out Door Unit Make: Blue Star / Carrier) , Aluminum Duction 22 Gauge With Curves & Bends Where Indicated For Easy Flow Of Air Tight By Applying Silicon Sealant After Fabrication. Hangers Will Be Provided To Ducts & Will Be Suspended Be Means Of G.I. Coated Rod & These With Not Be More Than 2.5 Mtr. Apart. Thermal Insulation With 19Mm. Xpe With Aluminum Foil For Supply & 13Mm. Xpe Return Air Ducts. Joints Will Be Lapped With Nitrile Tape For Better Insulation. (Laminar To Ahu & Return Air In All Four Corners) Ahu To Be Placed Near Ot, Not More Than 6 Meters. , Dustbin (Trio) , Storge Unit: Storge Unit: 1 Mm. Thick Stainless Sheet 304. The Storge Unit Should Be Divided 4 Equal Parts And Eachpart Should Have Indivdual Swing 8 Mm. Toughened Glass Door With Quality Stanless Steel Self- Closing Hinges Capable Of 180 Degree Swing Out And Secure Locking System. Each Part Will Be Provided With Removable Stainless Steel Racks Made From½ Circular ( Outer Diameter) Seamless Stniless Steel 304 Tubes Of 1 Mm. Thickness Placed At Intervals Of 1.5 Center To Center. The Overall Dimension Of The Stroge Unit Shall Be 1500 Mm. (Width) X 2100 Mm. (Height) 350 Mm. Depth Being Variable To Suit Architectural Layout. , Supplying, Installation, Testing & Commissioning Of F Floor Mounted, Scrub Station: Compact Surgical 2 Bay Scrub Sink Designed For Use In Ot Complex. Each Fixture Fabricated From Heavy Gauge 1 Mm. Thick Type 304 Stainless Steel Of Seamless Welded Construction, Polished To A Smooth Finish With A Front Access Panel Which Should Include, Stoppers And Strainers. Hands Free Operation Should Include Infra-Red Sensors With Built-In Range Of Adjustment. Thermostatic Mixing, Valve Control Should Be Located Behind The Access Panel And Maintain Constant Water Temperature. User Defined Setting Of Approximately 1 To 3 Min Should Be Available. (Size 1500Mm. X 675Mm. X 1105Mm. For 2 Persons , Electrical Db Supply Installation Testing And Commissioning Of Electrical Distribution Board: Should The Trandformers, If Any, Mains Failure Relays, Electrical Distrition Equipment And Circuit Protection Equipment For All Circuits Within The Operating Theatre. All Internal Wiring Should Terminate In Connectore With Screw And Clamp Spring Connections Of The Clip-On Type Mounted, On A Din Rail And Labelled With Indelible Propritary Lables, Individual Fuses Or Miniature Circuit Breakers Should Protect All Internal Circuits. , Pressure Relief Damper Supply, Installation, Testing & Commissioning Of Ss Fabricated Cascade Pressure Relief Dampers: Suitably Sized Air Pressure Relief Damper Should Be Placed Endabling Differential Room Pressure To Be Maintained.Counter-Weight Balancing System Should Be Prvided In The Prd To Maintain Positive Pressure Inside The Operation Room , C-9001 Supreme, Sliding Top Electric Table , C-9001 Supreme, Sliding Top Electric Table Led Operating Light Led Operating Light Having Following Specifications:- Maximum Luminance (1M): 160,000+160,000 Lux At 1 M Distance, Electrical Power: 150+90W, Power Consumption 2 X 11 A, Fitting: Ceiling Anchoring Ring Ceiling Pendant With 2 Brackets And 2 Spring Arms, Range Of Movement: 1 X 3600/ 1 X 3300, Recommended Room Height At Least 2.45 M, Max. Ceiling Load: 2X 218 Nm/650 N, Light Body Weight 9.2 + 7.5 Kgs, Light Body Depth: 1 X 130 Cm / 1 X 140 Cm, Air Shielding Surface 2 X 330 Cm2 Transformers: 2 X 450Va/ 230V/26V, Brightness Regulator 2 X 20- 500Va (Primary Voltage), Provided With 2 Sterilisable Handles With Each Done Easy Positioning By Sterilisable Handle, Focus Adjustable By Sterilisable Handle, Life Time Of Bulbs: , Uv System: Uv Rays Are Very Effective In Killing A Large Number Of Pathogenic Organisms Of Bacterial, Viral And Fungi Commonly Seen In Operating Theaters Such As Pseudomonas, Clostridium Difficile, Mrsa And Vre , De- Fumigation System: Fumigation In Operation Theatre Is A Process Of Gaseous Sterillization That Is Used For The Killing Of Micro-Organisms And Prevention Of Micro-Organisms And Prevention Of Microbial Grwth In The Air, The Surface Of The Wall, Or The Floor1.000 De-Fumigation Control Panel Is Installed Outside The Operation Theatre To Monitor The Room Pressure And To Start The De- Fumigation System From Outside The Operation Theatre, It Will De-Fumigation The Theatre In A Given Time And Will Switch-Om The Ahu To Increase Operation Theatre Pressure Without Operating The Surgeon Control Panel , Ot Corridor Area & Ot Complex With Per And Post Area Conductive Seamless Flooring With Coving On All Corners Supply Installation Testing And Commissioning Of Operation Theatre Flooring (Antistaic Conductive):2 Mm. Full Body Conductive Vinyl, Laid On A Semiconductive Adhesive Base. The Floor Finish Sholuld Terminate At The Room Perimeter Passing Over A Concealed Cove Former And Continuing Up The Wall For 100Mm. All Joints Should Be Welded With Electrodes Of The Same Compatible Material To Provide A Continuous Sealed Surface , Antibacterial / Antifungal Paint Providing And Applying Antibacterial Paint The Internal Surface Of The Room Walls Will Be Sprayed With Water Based Liquid Plastic Wall Glaze Or Equivalent Anti- Bacterial Paint, Approved By The Architect To A Mimnimum Dry Film Thickness Of 300 Microns. The Plastic Coating Will Overlap The Floor Covering Ceiling System And Doorframes By 25 Mm. To Provde A Continuous Sealed Surface. The Plastice Coating Will Be Non- Reflective And The Colour Will Be Submitted To The Architect For Approval. , Add 18% Gst (In Basic Rate Must Fill 0.18) , Add 1% Labour Cess (In Basic Rate Must Fill 0.01)
Contract Date: Jun 15, 2026 Contract Value : 1.21 Crore
Government Departments No of Bidders 4
46.
Health and Family Welfare #11114831 Technical Bid
Procurement Of Disposable And Implants Items For Ctvs Department Rgssh , Part-01 , Oxygenatormembrane(Adult) With Hard Shell Reservoir: 1. Shouldhaveamicroporoushollowfibre Membrane Oxygenator 2. Should Have Open Circuit Configuration 3. Should Have Hard Shell Venous Reservoir Of Capacity More Than 4000Ml. With Built Of Cardiotomy Reservoir With 30? Filter Capacity. 4. Shouldhavebloodflowrange0.5Ltrto7 Ltr/Min. 5. Should Have Priming Volume Less Than 220Ml 6. Should Have High Efficiency Heat Exchanger. 7. Venous Return Port ½” With Rotating Facility. 8. Should Have An Auto Vent Facility. 9. Port Size : Arterial Outlet, Venous Outlet 3/8” Venous Inlet ½” 10. Should Have Sampling Port. , Oxygenator Membrane (Semi-Adult) With Hard Shell Reservoir: 1. Shouldhaveamicroporoushollowfiber Membrane Oxygenator 2. Should Have Open Circuit Configuration 3. Should Have Hard Shell Venous Reservoir Of Capacity More Than 3000Ml. With Built Of Cardiotomy Reservoir With 30? Filter Capacity. 4. Should Have Blood Flow Range 0.5 Ltr To 3.5 Ltr/Min. 5. Should Have Priming Volume Less Than 180Ml 6. Should Have High Efficiency Heat Exchanger 7. Venous Return Port 3/8” With Rotating Facility. 8. Should Have An Auto Vent Facility. 9. Port Size : Arterial Outlet, Venous Outlet 3/8” Venous Inlet 3/8” 10. Should Have Sampling Port. , Oxygenator Membrane (Paed.) With Hard Shell Reservoir: 1. Should Have A Microporus Hollow Fiber Membrane Oxygenator 2. Should Have Open Circuit Configuration 3. Should Have Hard Shell Venous Reservoir Of Capacity More Than 1000Ml. With Built Of Cardiotomy Reservoir With 30? Filter Capacity. 4. Should Have Blood Flow Upto 2.8 Ltr/Min. 5. Should Have Priming Volume Less Than 140Ml 6. Should Have High Efficiency Heat Exchanger. 7. Venous Return Port 3/8” With Rotating Facility And Redurs 8. Should Have An Auto Vent Facility. 9. Port Size : Arterial Outlet 1/4”, Venous Inlet 3/8” With Redurs , Oxygenator Membrane (Neonatal): 1. Should Have Venous Inlet ¼”. 2. Arterial Outlet Port ¼” Tubing Size. 3. It Should Have Least Priming Volume Less Than 70Ml. 4. Arterial Flow Upto 1.2 Ltr/Minute. 5. Approximate Reservoir Capacity Should Not Be 600Ml. 6. Should Have Redurs. 7. Blood Inlet And Outlet Port Size ¼” Redu Able To 3/16”. , Pre-Connected Tubing Pack Adult With Arterial Line Filter: 1. Circuit Diagram Attached. 2. Tubing Should Have Transparent, Medical Implant Grade Pvc Of Class Vi Usp, Marked. , Pre-Connected Tubing Pack Paed. With Arterial Line Filter: 1. Circuit Diagram Attached 2. Tubing Should Have Transparent ,Medical Implant Grade Pvc Of Class Vi Usp, Marked , Pre-Connected Tubing Pack Paediatric Small. With Arterial Line Filter: 1. Circuit Diagram Attached 2. Tubing Should Have Transparent ,Medical Implant Grade Pvc Of Class Vi Usp, Marked , Pre-Connected Tubing Pack Neonatal. With Arterial Line Filter: 1. Circuit Diagram Attached. 2. It Should Have A Good Quality Arterial Filter Pore Size Should Have 35-40 Micron. 3. Tubing Should Have Transparent Medical Implant Grade Pvc Of Class Vi Usp,Marked. , Onlineblood Cardioplegia Delivery System: 1. Should Have In Built High Efficiency Heat Exchanger Of Metallic For Fast Cooling & Re- Warming. 2. Should Have Priming Volume Less Than 80Ml. 3. Should Have Max Flow Rate 1 Ltr/Min 4. Should Have Pressure Drop Not More Than 13Mmhg 500Ml/Min 5. Should Have Blood To Crystalloid Ratio Of 4:1 With Bride Connection Facilities And Interchangeable Tubing Ratio. 6. Should Have Auto-Vent Line System On Accidental Bock Of Cardioplegia Deliver Liner. 7. Pvc Tubing Should Have Medical Implant Grade Of Class Vi ,Usp,Marked. , Ante- Grade Root Cardioplegia Cannula With Side Arm: 1. Should Have Size 12Fr,14 Fr. & 16 Fr. 2. Should Have Regular Tip Stilate With Side Arm For Vent With Flange 3. Selection Strictly On Quality Basis. , Ante- Grade Root Cardioplegia Cannula Without Side Arm: 1. Should Have Size 12Fr, 14 Fr. & 16 Fr. 2. Should Have Regular Tip Stilate With Flange 3. Selection Strictly On Quality Basis. 4. Iso Certification , Coronary Ostial Cannula: 1. Should Have Malleable Shaft, Female Luer Lock, Radio Opaque Flower Tip Selection Strictly On Quality Basis. 2. Size 14, Fr ,12 Fr & 10 Fr , Coronary Ostial Cannula: 1. Should Have Flexible Silicon Pvc Tubing, Female Luer Lock, Radio Opaque Ball Tip Selection Strictly On Quality Basis. 2. Size 12Fr To 20Fr, 14, Fr ,10 Fr 3. Iso Certification , Retrogradecardioplegia Cannula: 1. It Should Auto Inflatable Balloon. 2. Itshouldhavepressuremeasuringline With 3 Way Connector. 3. It Should With Malleable Stilate. 4. Iso Certification , Vent Catheter (Adult): 1. Shouldhaveflexiblewithmalleablestilateand Multiple Side Hole At The Tip Of Cannula 2. The Proximal Part Should Have Memory For Easy Insertion 3. Iso Certification , Ventcatheter (Pead.): 1. Shouldhaveflexiblewithmalleablestilateand Multiple Side Hole At The Tip Of Cannula 2. The Proximal Part Should Have Memory For Easy Insertion 3. Size – 10,13,15, 16 Fr 4. Iso Certification , Rightanglevenouscannula With Wire Re-In-Ford: 1. Shouldhaveflexiblewiringreinforwith Plastic/Metallic Angled Tip. 2. Should Have Depth Marking Assist With Positing. 3. Iso Certification 4. Size : 10,12,14,16,18,20,22,24,26,28,30 Fr. , Singlestagevenouscannula With Wire Re-In-Ford: 1. Should Have Flexible Wire Reinfor, Multiple Side Hole With Smooth Tip. 2. Should Have Depth Marking Assist With Positing. 3. Iso Certification 4. Size : 10,12,14,16,18,20,22,24,26,28,30,32,34, 36 Fr , Two Stage Singlevenous Cannula With Wire Re-In-Ford: 1. Should Have Flexible Wire Reinfor, Multiple Side Hole With Smooth Tip With Side Hole And Stilate. 2. Should Have Depth Marking Assist With Positing. 3. Iso Certification 4. Size 51 X 36Fr, 32 X 40 Fr,34 X 46 Fr, Etc. , Two Stage Single Venous Cannula Flat With Wire Re-In- Ford: 1. Shouldhaveflexiblewirereinfor,Multipleside Hole With Smooth Tip With Side Hole And Stilate. 2. Should Have Flat In Middle 3. Should Have Depth Marking Assist With Positing. 4. Iso Certification 5. Size 51 X 36Fr, 32 X 40 Fr,34 X 46 Fr, Etc. , Clear View Blower: 1. Should Have Malleable Tip With Air Filter 2. Iso Certification , Intra Coronaryshunt: 1. Should Be Flexible. 2. Size 1, 1.25, 1.5, 1.75, 2.0 , 2.25, 2.5Mm 3. Iso Certification , Intra Carotid Shunts: A. Flexible All Sizes 1. It Should Have Inflatable Balloon In Both Ends Of The Lumen (Shunts) 2. Iso Certification , Coronary Artery Epicardial Retraction Clip.: 1. It Should Have Malleable Wire For Better Exposure. 2. Size- 3Mm ,4Mm,5Mm. , Connectors Straight: 1. It Should Be Sterile And Transparent 2. Size Required: ½X ½” , ½ X 3/8” , 3/8 X 3/8” , 3/8 X ¼” . ¼ X ¼” , Connector With Luer Lock: 1. It Should Be Sterile And Transparent 2. Sizes - ½ X ½” , 3/8 X 3/8” 3. Sizes-1/4X14. 3/8X38. 1/4X1/4X1/4 , Y- Connectors: 1. It Should Be Sterile And Transparent. 2. Size : ½X 3/8 X 3/8 , 3/8 X 3/8 X 3/8 ,3/8 X3/8X¼ ,¼X ¼ X 3/8;¼ X ¼ X ¼ , Femoral Venous (Perfusion) Cannula: 1. Should Have Flexible With Wire-Re-In Fordbuilt In Connector With Dilator. 2. Size-10,12,14,16, 18,20,22 & 24 Fr 3. Should Have Iso Certification , Femoral Arterio- Venous (Perfusion) Cannula Kit For Percutaneous Insertion: 1. Arterio -Venous Kit With Dilator And Insertion Kit For Minimal Invasive Cardiac Surgery. 2. All Sizes 3. Kit Should Have Two Seldinger Style Needles. Four Dilators To Guide Wire Length More Than 140Cm Scalpel Blade. 4. Should Have Iso Certification , Femoral-Arterial(Perfusion) Cannula: 1. Should Have Flexible With Wire-Re-In Ford Built In Connector With Dilators. 2. Size- 10,12,14,16,18,20,22 & 24 Fr 3. Iso Approved. , Tieband: Nil , Aortic Cannula With Curve Tip: Should Have Wire Reinford, Side Flange With Curved Tip Size: 16,18, 20, 22, 24 Fr , Aortic Cannula With Curve Tip: Should Have Wire Transparent Reinford, Side Flange With Curvedtip Size: 16,18, 20, 22, 24 Fr , Aortic Cannula With Straight Tip: 1. Size: 10,12,14,16,18,20,22,24 Fr. 2. Shouldhavestraighttipwithsideflangefor Fixation With Auto Venting Facilities. , Paediatric Aortic Cannula.: 1. Should Have Wire Reinford Built In Connector Straight Tip With Movable Auto Venting Stilate For Easy Cannulation. 2. It Should Have / Certification. Size : 8,10,12,14,16 Fr , Arterial Filterpaediatric: 1. Priming Volume Should Not More Than 70Ml Filter Size Should Be 35 To 40? 2. Attached 3/8” Dia. Tubing Loop 3. It Should Have Approved , Sterile Packing Tubing Pvc: 1. Size: (A)½” Dia. Of 10 Feet Length Tubing. (B)3/8” Dia. Of 10 Feet Length Tubing. (C) ¼”Dia. Of 10Feet Length Tubing. 2. Tubing Should Have Medical Implant Grade Of Class Vi Pvc, Usp,Marked. , Cardioplegia Cannula Paed.: 1. Should Be With Stilate And Side Flange For Fixation. 2. Size 18 G Length Of Approx. 6.5Cm , Cardioplegia Cannula Paed.: 1. Should Be With Stilate And Side Flange For Fixation. 2. Size 18 G Length Of Approx. 16Cm , Cononary Ostial Cannula Of Silicon Or Pvc With Side Bulb: 1. Paed & Neonatal With All Sizes , Artriotomy Cannula: 1. Should Have A Polyurethane Tube With Bulb With Female Luer Lock 2. Sizes 2Mm To 6Mm Tip , Ima Cannula With Ball Tip: All Sizes , Double Lumen Venous (Perfusion Cannula): 1. For Veno- Venous Ecmo Support. 2. Shouldhavebloodinletandoutletportwith Connector Certified. 3. All Sizes , Haemoconcentrator Adult: A. It Should Have High Efficiency Haemoconcentrator With Material Of Polysulphone / Polypropylene B. It Should Have Membrane Surfa Area Of 1.0M2 Or Variable To ± 1. C. Primary Volume Of Should Be Less Than 90Ml D. Transmembrane Pressure Should Have Not More Than 500 Mmhg. E. It Should Bewith Tubing Attached/Separate For In And Out Port & Bag. , Haemoconcentrator Peadiatric: A. It Should Have High Efficiency Haemoconcentrator With Material Of Polysulphone / Polypropylene. B. It Should Have Membrane Surfaarea Of 0.7 M2 Or Variable To ± 1. C. Primary Volume Of Should Be Less Than 70Ml. D. Tran Membrane Pressure Should Not Be More Than 500 Mmhg. E.It Should Be Withtubing Attached/Separate For In, Outport& Bag , Haemoconcentrator Neonatal: A. It Should Have High Efficiency Haemoconcentrator With Material Of Polysulphone / Polypropylene. B. It Should Have Membrane Surfa Area Of 0.2 M2 Or Variable To ± 1. C. Primary Volumeshould Not Be More Than 30Ml D. Transmembrane Pressure Should Not Be More Than 500 Mmhg. E. It Should Be With Tubing Attached/Separate For In And Out Port & Bag. , Adult Cardiac Sucker: 1. It Should Be Plastic Bullet Tip With Handle Compatible In ¼”Tubing. 2. Tip Size-5Cm ± 0.5Cm , Paediatric Cardiac Sucker: 1. Itshouldsmallinsize,Plasticbullettipwith Handle Compatible In ¼”Tubing 2. Tip Size-2.5Cm ± 0.5Cm , Pericardial/ Intracardial Sumps: 1. Shouldhaveflutedtipencasedstainlesssteel Sprig. 2. Tip Is Attached To Soft Flexible Tubing Ending With Connector. 3. Sizes 12 Fr To 20 Fr. , Disposable Pressure Transducer Kit.: 1. Kit Should Bewith Disposable Transdur 2 Three Way Stop Cock. 2. Test Port Provision 3. Gold Plated Connector Wires 4. Shouldbecompatiblewiththepresentsetof Monitors. 5. Should Have Integrated Flushing Devi. 6. Shouldhavedifferentcolorcodingforarterial ,Cvp And Pa. 7. Requireinbothsingletransdurkitpackand Double Transdur Kit Pack. 8. Put Arm Strap Provision , Pressure Transducer Kit For Close Blood Sampling.: 1. Kit Should Bewith Disposable Transdur Setwith All Acssory And Cable. 2. Shouldbecompatiblewiththepresentsetof Monitors. 3. Should Have Plated Connected Wires & Provision For Arm Strap 4. Should Have Auto Flushing Devi With Reservoir . 5. It Should Have Self Iling Test Port For Close Blood Sampling To Prevent Blood Loss And Infection. 6. It Should Be Certified. , Leukocyte Reducing Arterial Blood Filter For Extracorporeal Servi.: A. Should Have The Following Specification. B. Leukocyte Reducing 40Micron Surfa Modified Polyster Media To Remove Activated Neutrophils. C. 220 Ml Prime Volume And Flow Rate Of 6L/Min. D. Automatic Air Venting With Dedicated Air Vent E.Marked With 3/8 Inch Barbed Inlet And Outlet Ports And With Bypass Loop. , Bloodcardioplegia Filter With Leukocyte Reduction: A. Should Have The Following Specification. B. Leukocyte Reducing 40Micron Surfa Modified Polyster Media To Remove Activated Neutrophils C. 95Ml Prime Volume And Flow Rate Upto 350Ml/Min D.Marked With 1/4 Inch Connectors. , Pre-Bypassfilterforcbp Circuit: A. 0.2Micron Filter For Priming And Should Have The Following Specification. B. Recirculation Phase. C. Removes Particulate Debris And Microbial Contaminants From Extracorporeal Circuit. D.Markedwith3/8In.Inletand½in.Outlet Ports. E. 220Ml Prime Volume. , Arterial Line Filter For Paediatric Use: A. Should Have The Following Specification. B. 40Micron Lock Woven Polyster Screen. C. Prime Volume Less Then 30Ml With Upto 3L/Min Of Flow Rate. D. Port Design To Allow ¼ Inch. Tubing. , Leukocyteremovalfilterfor Red Blood Transfusion: 1. Should Have The Following Specification. 2. High Efficiency Leucocyte Removal Filter, Polyster Media, For One Unit Of Whole Blood Or Packed Ll. 3. Filter Hold Up Volume Of 20Ml After Recovery And Leucocyte Residual Averaging Less Than 2X 105/Unit. 4. Primes Directly With Red Lls And With Self Levelling Drip Chamber. 5. Marked. , Microaggregatefilter(B.T. Filter): A. Should Have The Following Specification. B. 40Micronfiltertoremovemicroaggregate, Debris And Clots From Stored Or Salvaged Blood. C. Hold Up Volume Of 20Ml. D. Gravity Prime. , Disposable Centrifugal Pump. Adult And Paediatric.: 1. Compatiblewith Sarns Centrifugal Pump. 2. Should Have Iso Certification. , Disposable Centrifugal Pump. Adult And Paediatric: 1. Compatible With Medtronic Centrifugal Pump Adult And Paediatric. 2. Should Have Iso Certification. , Disposable Flow Connector/Sensor For Centrifugal Pump: 1. For3/8”Tubingand¼”Tubingcompatibleto Medtronic Flow Probe. 2. Should Have Iso Certification. , Aortic Punch: 1. Size -3,3.5,4,4.5, 5 Mm 2. Should Have Iso Certification. , Cautryplate Withcordand Connector For Compatibility.: Patented Safety Ring Technology With Cord For Adult And Paediatric As Universal Size ,Disposable Grounding Plates For Electro Surgical Use, With Thin Conformable, Tear Resistant, Fluid Resistant, Occlusive, Polypropylene Backing, Coated With Thick And Soft Hydrophilic Conductive Adhesive Gel. Plate Design To Have Handling Tabs. , Neonatal Triple Lumen: Neonatal Tripple Lumen Radio Opaque Polyurathane Tripple Lumen Catheter 20, 23, 23G, Dilator 5 Fr, Introdur Needle 21G Kit For Injecting Orinfusingdifferentsolutionandmedications. Ntimetermarkingfrom5to12cmguidewire Should Be Nitinol (Kink-Resistant J Guide Wire.) Size- 4.5 Fr- Length-8Cm, 10Cm. Us / Rtified. , Four Lumen Catheter: Pur Four Lumen Intravenous Catheter Trey Presentation Should Contain Only 4 Lumen Catheter 8.5 Fr , 16, 20Cm Length With Lumen Size 16,14,18. 18G Introdur , 1Graduated J Guide Wire , 1 Dilator 1 Secondary Fixation Wing 3 Injection Caps And 1 Scalpel . , Femoralarterialcannula (Adult): Femoral Arterial Cannula (Adult) Seldinger Technique Polyethylene With Radio Opaque Line And Anti-Kink Collar And Wing Hub For Skin Fixation. Size- 1. 20G- Length 8Cm. One Transparent Catheter (Polyethylene), One Introdur Needle, Should One Straight Guide Wire With Flexible Tip. Size- 2. 18G- Length 10Cm. One Transparent Catheter (Polyethylene), One Introdur Needle, Should One Straight Guide Wire With Flexible Tip. Size- 3. 16G- Length 15 & 20Cm. One Polyurethane With 5 To 20 Cm Marking On Catheter, One Introdur Needle, J Guide Wire- Advanr. Us Approved , Femoralarterialcannula (Paed): Femoral Arterial Cannula (Paed) Polyurathane With Radio Opaque Line Introdud By Seldinger Technique With Integral Polyurathane Extension Tube Length 4.5Cm With Fixation Wing. Presented In A Peel-Pack. One Polyurathane Catheter, One Introdurneedle, One Straight Guide Wire With Flexible Tip, One 50 X 50 Cm Drape Sheet. Size- 22G- Length 4, 6, 8, 20Cm. Usapproved , Spirallacto(Polyethylene) Tubing: 1. Spirallycoiledtubing(Polyethylene)Fordrug Infusion. 2. Size- 100, 150, 200, 300 & 400Cm Us/ Rtified , Polyethylene Pressure Extension Tube: 1. Polyethylene High Pressure Extension Tube 2. Size- 11, 30, 50, 100, 150 & 200Cm. Us / Rtified , Anti-Microbial Impregnated Triple Lumen Catheter: 1. Impregnated With Anti-Microbial Agents With Nitinol Kink-Resistant J Guide Wire. A. Adult Size- 7.5 Fr- Length 16 & 20Cm B. Paedsize-4.5Fr-Length6&12.5Cmus Approved , Pur Iv Acss Devi: 1. Polyurathane Iv Acss Devi 2. Size- 16G, 18G, 20G & 22G , Dressing(Film): A. Ultraresistant Thick Drape Used In Under The Retractor, Ultra Absorbent Pad Keeps Surgical Site Dry, Containing Modified Llulose For Good Hemostatic Action, Bactericide Action With Total Incision Covering. Size : 50X50cm, 38.15.10, 38.30.15, 38.45.45, 38.45.60, 3591, 6X7cm Sizes Variable To ± 5Cm B. Absorbent Clear Acrylic Dressings - Transparent Wound Dressing Consisting Of A Clear, Conformable, Absorbent Pad With A Acrylic Polymer Pad Technology Enclosed Between An Outer Low Friction, Breathable, Waterproof, Viral & Bacterial Barrier Film . Perforated Wound Contact Layer Coated With Moist Skin Adhesive .Pad Size Should Be Slightly Short Then The Dressing Size Variable To ± 2Cm 1. Dressing Size: 6 Cm X 5 Cm, 2. Dressing Size: 9Cm X 6.5Cm, 3. Dressing Size: 7.5Cm X 9.5Cm, 4. Dressing Size: 11 Cm X 12.5Cm, 5. Dressing Size: 15Cm X 15Cm, 6. Dressing Size: 14.5Cm X 15.5Cm, 7. Dressing Size 8.5Cm X 10.7Cm, 8. Dressing Size: 20Cm X 10Cm, 9. Dressing Size: 17Cm X 19Cm , Surgical Brush And Povidone Iodine: With Sponge Impregnated 12% Povidone – Iodine In A 15Ml Solution Of Teepol, P.E.G. And Water Supplied With Nail Cleaner , Surgical Brush And Chlorohexidine: With Sponge Impregnated 20% Chlorohexidine – Iodine In A 15Ml Solution Of Iso Propyle- Alcohol And Water Supplied With Nail Cleaner. Us Approved , Polyurathane Long Cannula: Size- 16G, 18G, 20G, 22G & 24G Us Approved , Anti Uav Extension Line: 1. Anti Uav Extension Line For Light Sensitive Drugs 2. Size- 100, 150, 200Cm 3. Us Approved , Thermodilution Catheter 5 Lumen With Insertion Kit: 1. Catheter Should Have Five Lumen 2. Percutaneous Insertion Kit Separately With All Acssory 3. Iso Certification , Triple Lumen Cvp Kit Paed.: 1. Lumen Size- 18/20/18 G 2. Material Polyurathine, J Type Preferable Nitinol Guide Wire For Anti Kink. Needle Dilator . 5Ml Syringe Inside The Kit 3. It Should Be Approved Size-5.5 Fr. 8Cm , Etoandplasmasterilizer Indicator.: Nil , Chest Drainage Catheter: (Iso/): 1. Thoracic Drainage Catheter. 2. Extra Soft Catheter Is Gentle To The Body Tissues & Most Suitable For Thoracic Drainage. 3. Distalendisopenwithsupersmoothlarge Eyes To Maximize The Drainage From The Chest. 4. Proximal End Is Fitted With Specially Designed Tapered Tongue To Provide Exllent Forpsgrip And Non- Traumatic Insertion. 5. Catheters Are Marked At Every 2Cm From The Last Eye To Asrtain The Depth Of Plament. 6. Sterile, Double Packed In Peelable Pouch Pack. 7. Should Be /Iso Approved , Angled Chest Drainage Catheter: (Iso/): 1. Thoracic Drainage Catheter With Angle. 2. Extra Soft Catheter Is Gentle To The Body Tissues & Most Suitable For Thoracic Drainage. 3. Distalendisopenwithsupersmoothlarge Eyes To Maximize The Drainage From The Chest. 4. Proximal End Is Fitted With Specially Designed Tapered Tonguetoprovide Exllentforpsgrip And Non- Traumatic Insertion. 5. Catheters Are Marked At Every 2Cm From The Last Eye To Asrtain The Depth Of Plament. 6. Sterile, Double Packed In Peelable Pouch Pack. All Sizes 7.Should Be /Iso Approved , Under Water Seal Bottle (Chest Drainage Bottle). (Iso/): 1. Double Chamber Compact Unit Has2ltr Capacity Making It Suitable For All Cardiac And Thoracic Produres. 2. Easy To Read Graduation Help To Determine The Drainage Volume Precisely. 3. Clearly Marked Initial Level Ensures The Under Water Seal. 4. Separate Suction Port Is Providedfor Connection With Suction Unit. 5. Kink Resistant Large Bore Tubing Facilitates Unrestricted Flow. 6. Unit Is Provided With Metal Hangers And Floor Stand. , Snugger Set: Adult And Paediatric , Embolectomycatheter: Size 4,5,6 Fr Usa / Rtified , Tenckhoff Catheter Adult: For Peritoneal Dialysis Should Have Usa / Rtified Size Adult , Tenckhoff Catheter Pediatric: For Peritoneal Dialysis Should Have Usa / Rtified Size Pead , Tenckhoff Catheter Neonatal: For Peritoneal Dialysis Should Have Usa / Rtified Size Neonatal , Graft Embolectomycatheter: Size 4,5,6,7 Fr , Anti Microbial Incise Drape Size 34X35 Cm, 56X45 Cm: 1. Incise Drape Comprise Of Polyester, Thin, Breathable Low Memory Idophor, Impregnated Film. 2. Drape Should Be Coated With Pressure Sensitive Acrylate Adhesive , Antimicrobial Drape For Minimally Invasive Surgery Size 26X20 Cm: Polyester Film Idophor Coated With Hypo Allergic Adhesive Incise Drape Differentiated By A Frame Delivery System For One Person Application. , Reinford Disposable Gown: Made Non-Woven Fabric With 100% Polyester Cuffs, Latex Free, Sleeves And Set-In-Sleeves Seams Are Ultrasonic Welded, Double Layered With Reinforment Layer On Chest And Forehand Area, Fluid Repellant, Fire Resistant, Eto Sterilized,Packed With 2 Hand Towel. , Sterile Disp. Drape Kit For Open Heart Surgery: A. Cabg Pack - Sterile Wrap Size : 115Cm X 115Cm, Back Table Cover, Reinford 152Cm X 230Cm-1Pc, Tape Strips 10Cm X 55Cm -2Pcs, Suture Bags-2Pcs, Back Table Cover, Reinford 140Cm X 190Cm- 1Pc, Utility Drape With Tape 75Cm X 75Cm-1Pc, Perineal Drape 188Cm X 242Cm With Split 45Cm X 95Cm & Positioning Tape &Control Plus Fabric Reinforment- 1Pc, Cv Split Drape 320Cm X 224Cm X 295Cm With Positioning Tape & Control Plus Fabric Reinforment -1Pc. Bar Drape 193Cm X 239Cm With Positioning Tape & Tube Holders & Control Plus Fabricreinforment- 1Pc. Size Variable To ± 2Cm. It Should Have / Rtified. B. Valve Replament Drape - Drape With Size 264Cm X 364Cm X 194Cm, Size Variable To ± 2Cm With Pouches Control Plus Fabric Reinforment, Tube Holders With One Utility Drape Sheet. It Should Have Iso Certification C. Cardiac Produre Drape With Adhesive Incise Area On Chest & Legs - One Drapewith Armboard Covers 108 Inch. X 80 Inch. X 126 Inch, 12 Inch. X 15 Inch. Chest Adhesive Incise Area, 22 Inch. X 38 Inch. Leg Adhesive Incise Area, Heavy Duty Fabric, Control Plus Fabric Reinforment, Longitudinal Flaps, Tube Holders. It Should Have / Approved , Act Tubes: Compatible With Actalyte Act Machine , Act Cartridge: Compatible Withmedtronic Act Machine , Vascular Graft Eptee: Size 3, 3.5, 4, 4.5 ,5 ,6, 8 Mm X 10Cm Size 6,7,8Mm X 30,40,50,60,70,80,90Cm Should Have/ Rtified , Vascular Graft Eptee With Thin Wall: Size 3, 3.5, 4, 4.5 ,5 ,6, 8 Mm X 10Cm Size 6,7,8Mm X 30,40,50,60,70,80,90Cm Should Have/ Rtified , Vascular Graft Eptee With Thin Wall And Carbon Coated: Size 3, 3.5, 4, 4.5 ,5 ,6, 8 Mm X 10Cm Should Have/ Rtified , Vascular Graft Eptfe: Size 16,18,19,20,22 Mm X 20,30,40 Cm Length Should Have/ Rtified , Dacron Swage Graft: Size 7Mm An8 Mm Length 10Cm Or More , Soft Cloth Reinforment Dressing: A. Central Venous Catheter Dressing With Effective Antimicrobial Action. Polyurethane Film With Reinforment Of Soft Cloth 8.5Cm X 11.5Cm & Size: 7 Cm X 8.5Cm . Single, Sterile, Transparent, Semi-Permeable, Water And Bacteria Proof, Thin Conformable Polyurethane Film With One Half Laminated With Soft Cloth Breathable Backing For Enhand Grip On Challenging And Cvc Applications. Has A Long Slit To Conform Around The Civ And & Micro- Porous Label. Has Two Extra Secural Tape For Added Strength & Better Securement. With Unique Paper Window Frame Delivery Design. B. Iv Kit With Transparentdressingfor Peripheral Inserted Catheters : Single Pack Single, Sterile, Transparent, Semi-Permeable, Water And Bacteria Proof, Thin Conformable Polyurethane Film With One Half Laminated With Soft Cloth Breathable Backing For Enhand Grip On Challenging And Cvc Applications. Has A Long Slit To Conform Around The Piv And & Micro-Porous Label. Has Two Extra Secural Tape For Added Strength & Better Securement. With Unique Paper Window Frame Delivery Design Wipe Impregnated With 2% Chlorhexidine Gluconate And 70% Isopropyl Achohol, Synthetic Polyisoprene Based Textured Surfa Material Oftourniquet (Latexfree) Sterile Gauze Pie. , Transparentdressingforpost Opp.: Single Sterile Non-Adherent Absorbent Pad (Compressed Rayon Fiber) Bonded To A Larger Soft Cloth Macro-Porous, Stretchable, Rounded Corners Backing, Coated With A Border Of Hypoallergenic, Water-Resistant Pressure Sensitive Hypo-Allergic Adhesive. 6X8cm, 9X15cm, 9X20cm, 9X25cm, 9X30cm Size Variable To ± 2Cm. , Transparent / Soft Cloth Dress. With Abs. Pad: Single, Sterile,Transparent,Semi-Permeable, Water And Bacteria Proof, Thin Conformable, Polyurethane Film Coated With Water Repellant Acrylate Hypoallergenic Adhesive With Paper Window Frame Delivery And Having A Non Adherent Absorbent Pad (Compressed Rayon Fiber) For Very Good Absorbent And Strike Through Effect. 5X7cm, 8X10cm,9X15cm, 9X25cm, 9X35cm Size Variable To ± 2Cm. , On Line Cardiac Output Monitoring Transdur & Kit: Compatible With Edward Monitor. , Eptfe Cardiovascular Patch: Thickness – 0.6 Mm/0.4 Mm Size-Inches 50 X 75 Mm , Eptfe Cardiovascular Membrane: Thickness – 0.1 Mm Size-Inches 50 X 75 Mm , Eptfe Felt Soft & Hard: Sizes-5 X 7.5Cm & 4” X 4” , Dacron Cardiovascular Patch.: 4 X 4 “ , Dacron Cardiovascular Patch.: 2 X 2 Inches , Closed Circuit Suction Set: Nil , Multi Vessel Perfusion Adaptor: Should Have Four Arm With Pinch Clamp , Disposable Tubing Organizer.: Should Have Port For Multi Sized Perfusion Tubing. E.G. 3/16, ¼, 3/8,1/2,Inch Tubing. , Double Lumen Endobronchial Tube: All Sizes Both Side (Rt. & Lt) Usa / Rtified. Should Have With Endobronchial Blocker , Bifurcated Rapid Priming Set: Should Have 1/4” Bifurcated With “Y” Connector Should Have Spike In Both Ends , Pressure Dome P 20 Red: Should Have Sterile With Male Luer Lock. , Linear Cutter 75Mm Tlc 75 (Ref): Should Have Sterile. , Linear Stapler: Should Have Sterile. , Blade Sternalsaw: Compatible For Sarns Sterna Saw , Monopolar Hand Cautery Pencil (Disposable): It Should Have Universal Three Pin Connector For All Kinds Of Major Cautery Machines. , Tip Cleaner (Disposable) For Monopolar Hand Cautery Pencil: Tipcleanershouldbeintheseparatesterile Packing. , Monopolar Hand Cautery Pencil (Disposable) Cautery With Pencil Tip Cleaner (Disposable): It Should Be Sterile And Supplied In Sterile Packing With Cautery Pencil Tip Cleaner. , Cautery Switch With Polyurethane Coated Surgical Tip: Button Switch Pencil With Polytetrafluoroethylene Coated Electrosurgical Tip. , Cautery Tip: Polytetrafluoroethylene Coated Electrosurgical Ball Tip, Size – 5 Cm , Male To Male Connector: It Should Have Male Luer Lock In Both Ends. It Should Have Iso Certification , Vial Adapter: For Withdrawal Of Sterile Solution From Sterile Vial To Maintain Sterility It Should Have Iso Certification , Eye Shield Fog Free Mask With Visor: 1. It Should Be Consisted Fog-Free Multilayer With Visor. 2. It Should Be Made Of Pleat-Styple With Ties. 3. It Should Have High Fuild Resistan Capability. 4. It Should Have Particular Filtration Efficiency More Than 99%. 5. It Should Have Baterial Filtration Efficiency More Than 99%. 6. It Should Have Iso Certification. , Fluid Shield Fog Free Mask: 1. It Should Be Consisted Fog-Free Multilayer. 2. It Should Be Made Of Pleat-Styple With Ties. 3. It Should Have High Fuild Resistan Capability. 4. It Should Have Particular Filtration Efficiency More Than 99%. 5. It Should Have Baterial Filtration Efficiency More Than 99%. 6. It Should Have Iso Certification. , Microbial Sealant: 1. It Should Have Antibacterial Properties. 2. It Should Be Made Of Cyanoacrylate Technology. 3. Itshouldbecapabletosealand Immobilizes Dangerous Pathogens/Mrsa. 4. Itshouldbeeasy-To-Useapplicator, Polymerized In Less Time. Size:(A) Approximatecoverage:25Cmx 25Cm, (B) Approximate Coverage: 25Cm X 50Cm 5. It Should Have Iso Certification. , Long Cardiopleagia Cannula (Forminimal Invasive Surgical Produres): 1. It Should Have A Length Of More Than 30Cm With Luer Connection. 2. It Should Be Supplied With A Stainless Steel Introdur Needle. 3. It Should Be In Following Sizes 12 Ga/9Fr. 12Ga/9Fr. 4. It Should Have Iso Certification , Disposable Soft Tissue Retractor(Protector) For Minimal Invasive Cardiac Surgery: 1. It Should Be Mode Of Latex Free Silicone Rubber 2. It Should Have High Flexibility For Easy Insert In Situ. 3. It Should Be Capable For Self Holding, For Incision From 7 To 12Cm. 4. It Should Have Iso Certification. , Disposable Coronary Arteriotomy Knife: 1. It Should Be Sterile With, In Builthandle. 2. It Should Have Straight Sharp Pointed Tip For Arteriotomy. 3. Tip Size Should Not Be More Than 1Mm. 4. Shouldbeabletomakeaclearincised Arteriotomy Of Arteries <1Mm In Size. 5. Should Have / Approved. , Disposable Vascular Clamp Inserts: Forbetter Grip And Minimizing Trauma , Suture Organiser Disposable For Valve Surgery: 1. Shouldbe Ableto Stabilizesuturesforvalve Surgery. 2. Should Not Damage The Sutures. 3. Suture Should Not Get Entangled. 4. Capable Of Holding 10-20 Sutures 5. Should Have Sticking In The Bottom So It Adheres To Drapes , Compression Adhesive Bandage For Leg/Arms: 1. It Should Have Medical Grade Bio- Compatible, Pressure Sensitive And Trauma Free Adhesive. 2. It Should Be Breathable Latex Free. 3. It Should Have Maximum Pressure Compression For Legs Or Arms Of Harvested Veins And Arteries For Coronary Grafting. Sizes Variable To ± 1 Meter Long A. 10 Cm X 4,5,6 Meter Long. B.05 Cm X 4,5,6 Meter Long , Silver Mesh Dressing: 1.It Should Have Antimicrobial Cotton, Non Woven Gauze. 2.It Should Have Soft Comfortable Impregnated With Silver Sulphate. 3.It Should Have Various Sizes And Sizes Variable To± 02 Cm. Sizes Variable To ± 1 Meter Long A. 10 Cm X 10Cm B.05 Cm X 05 Cm C. 10Cmx 20Cm D 20Cm X 20 Cm , Vsd Ring: Cloth Bases , Sterile, 2 Circular Cloth With Ntral Hole , The Lower Cloth Should Be Bigger Than The Upper One, 2 Cloths Stitched At 12,3,6 And 9O Clock Positions , Part-02 , Intra Aortic Balloon Catheter.: 1. Should Have Membrane For Improved Abrasion Resistan. 2. Should Have A Small Profile Of7 Fr To 7.5 Fr. 3. Should Be Available In Volume Of 34Cc, 40Cc & 50Cc. 4. Balloon Diameter At 2Psi Should Be 15Mm. 5. Insertable Length Should Not Exed 725Mm. 6. Insertion Kit Should Be Provided Separately. 7. It Should Have Isoapproved. Sizes 34, 40 , 50 Cc Catheter Compatible With Datascope Iabp , Annuloplastyring,Rigidfor Mitral Valve: 1. Constructed Of Titanium Alloy With A Silicone Rubber Sewing Ring. 2. Closed Ring For Stable Remodelling. 3. Restores The Natural Size(3:4) & Shape In Systolic Position Ratio. 4. Marking Sutures For Accurate Plament. 5. Preferable Saddle Shaped. 6.Iso Approved. Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm. , Annuloplasty Ring, Mitral Valve For Ischemic Mr: ?Rigid Ring For Durable Repair ? Complete Ring For Stable Remodelling ?Asymmetrical Designfor Asymmetrical Dilation P2-P3 Region ?Increased Sewing Ring Margin In P2-P3 Region. ?Dippedp3regiontoaccommodate Stress From Downward Lv Displament ?Iso Approved ? Sizes : Even No.24Mm To 34Mm. ?Odd No. 25Mm To35mm. , Annuloplastyring,Semi Flexible For Mitral Valve: Three Dimensional Design To Suit The Annulus Normal Of The Mitral Valve. Semi Flexible In Nature. Isoapproved. Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm. , Annuloplasty Ring, Flexible For Mitral Valve: Barium Impregnated Silicone Strip With Polyester Fabric For X-Ray Visibility. Flexible Design To Allow Dynamic Motion . Isoapproved. Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm. , Annuloplastyringsemirigid With Double Saddle Shape: 1. For The Use Of Mitral Valve Repair 2. It Should Be Semi Rigid Double Saddle Shaped Ring Design Specially For Mitral Position For Helping Stable Remodelling. 3. It Should Havespeciallycraftedsewingcuff Has Visible Ledge That Permits Plament Of Sutures. 4. Iso Approved. 5. Sizes : Even No.24Mm To 40Mm. , Annuloplastyrings3drigid For Tricuspid Valve: Annuloplasty Ring With Three Dimensional Shapes With Incomplete Ring Shape To Avoid The Sensitive Conduction System Anatomy And Downward Angle In Septal Region To Help Redu The Stress On Sutures And The Risk Of Ring Dehisn. Iso Approved Sizes : Even No.24Mm To 34Mm. Oddno. 25Mm To35mm , Annuloplasty Ring, Flexible For Tricuspid Valve: 1. Flexible Design To Allow Dynamic Annular Motion. 2. Open At Annuloseptal Commissure To Avoid Conduction System. 3.Iso Approved , Annuloplastyringsemi Flexible For Tricuspid Valve: 1.Semiflexibledesigntoallowdynamic Annular Motion. 2. Open At Annuloseptal Commissure To Avoid Conduction Syatem. 3.Iso Approved. , Prosthetic Heart Valve Bileaflet Mitral: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radioopaque Disc To Be Visualized On X- Ray & Fluoroscopy And Disc Should Be Mri Compatible. 3. Should Be Of Lowprofile& Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Wide Range Of Sizes For Mitral 23 To 35 Mm. 6. Easy Torque Rotation And Intraoperative Adjustment Should Be Possible. 7. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 8. Valve To Be &Iso Approved. , Prosthetic Heart Valve Bileaflet Aortic & Mitral Valve.: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radioopaque Disc To Be Visualized On X- Ray & Fluoroscopy And Disc Should Be Mri Compatible. 3. Should Be Of Low Profile & Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Wide Range Of Sizes For Aortic 17 To 31 Mm. 6. Easytorquerotationandintraoperative Adjustment Should Be Possible. 7. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 8. Valve To Be &Iso Approved. , Prostheticheartvalvemono Leaflet Mitral & Aortic: 1. It Should Superior Hemodynamic. 2. It Should Be Rotatable Within The Swing Ring. 3. It Should Have Rigid Tilting Disc Single Leaflet Heart Valve. 4. It Should Have In Various Sizes From 17Mm To 25 Mm For Aortic Position And Size 23Mm To 31Mm For Mitral Position. 5. Should Have Approval For Imported Valve. No / Approval Require For Indigenous Made Heart Valve. Indigenous Valve Doesn’T Require /Approval , Prostheticheart Valve Bileaflet Aortic With Conduit: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radioopaque Disc To Be Visualized On X- Ray & Fluoroscopy And Disc Should Be Mri Compatible. 3. Should Be Of Low Profile & Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Wide Range Of Sizes For Aoritc 19 To31 Mm. 6. Easytorquerotationandintra-Operative Adjustment Should Be Possible. 7. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 8. Valve To Be & Approved. 9. Valveshouldbeattachedwithknittedlow Porosity Coated Graft. All Size.Should Have Iso Approved , Low Profile Prostheticheart Valve Bileaflet Aortic: 1. Bileaflet Pyrolytic Carbon Disc Valve 2. Radio-Opaque Disc To Be Visualized On X- Ray & Fluoroscopyanddiscshouldbemri Compatible. 3. Should Be Of Low Profile & Thromboresistan Characteristics. 4. Opening Angle Should Be 800-900 5. Easytorquerotationandintra-Operative Adjustment Should Be Possible. 6. Sewing Cuff Should Contain Suture Marker For Accurate Plament. 7. Valve To Be & Approved. 8. Sewingringshouldbethinnerandmore Pliable 9. Should Provide Extra Eoa Than Standard Valves 10. 17Mm To 23 Mm 11. Should Have Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral: Specification , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Stent–Less Porcine Tissue Aortic Valve): A. All The Sizes Should Be Available B. Should Be In Clinical Use With Long Term Good Results C. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Stent-Less Pericardial Tissue Aortic Valve): A. All The Sizes Should Be Available B. Should Be In Clinical Use With Long Term Good Results C. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Mitral Valve): A. All The Sizes Should Be Available B. Second Generation Valve With Xenologix Treatment C. Should Have Long Term Good Results Available In Literature And More Than 15 Years Durability In Vivo D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Mitral Valve): A. All The Sizes Should Be Available B. Low Profile Third Generation Valve With Thermafix Fixation C. Should Have Long Term Good Results Available In Literature D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Aortic Valve): A. All The Sizes Should Be Available B. Second Generation With Xenologix Treatment C. Should Have Long Term Good Results Available In Literature And More Than 15 Years Durability In Vivo D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Aortic Valve [Low Profile With Grater Eoa]): A. All The Sizes Should Be Available B. Low Profile Third Generation With Thermafix Treatment C. Should Have Long Term Good Results Available In Literature D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pericardial Stented Tissue Aortic Valve With Pericardial Covered Stent): A. All The Sizes Should Be Available B. Third Generation Pericardial Stented Valve With Stunts Covered With Pericardium And Treated With Links Technology C. Should Have Good Long Term In Vitro Results Available In Literature. D. Us Andappoved E. Aortic Valve Delivered Larger Eoas, Exllent Hemodynamic With Single- Digit Pressure Gradients F. Elimination Of Tacking Suture At Loupe Of Commissure Redud Risk Of Tearing G. High Strength Titanium Stunts Andquick Click In Handle Attachment , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Porcinebioprostheticlow Profile Mitral And Aortic Valves): A. Second Generation With Anti Calcification Treatment By Linx Technology B. Low Pressure Fixation C. Results Studied In Acss Of More Than 20 Years D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Porcine Bioprosthetic Low Profile And Aortic Valves): A. Second Generation With Anti Calcification Treatment By Linx Technology B. Low Pressure Fixation C. Results Studied In Acss Of More Than 20 Years D. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Porcinebioprostheticlow Profile Mitral And Aortic Valves): A. Third Generation With Amino- Olic Acid Anti Calcification Treatment With Covalent Bonding With Glutraldehyde . B. Physiologic Pressure Fixation C. Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Bovinejugularvein Pulmonary Valve Conduit): (All Sizes ) Isoapproved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Pulmonary Bioprosthesis Conduit): (All Sizes ) Isoapproved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Bovine Pericardium): Pericardium Patch Iso Approved , Bioprostheticheartvalve& Pericardium Aortic & Mitral (Bioprostheticaortic Valve (Suture Less)): Trated Valve To Redu Calcification. Shouls Have Self Expending And Elastic Alloy Stent. Should Have Covered With Film Of Carbofilm For Biocompatibility . Isoapproved , Heart Stabilizing System: 1. Tissue Stabilizing System With Malleable Pods For Better Grip And Anastomosis. 2. It Should Be Compatible With Various Cardiothoracic Retractors. 3. It Should Be Suction Based. 4. Should Be Trislot Design Of Pods For Better Visualization 5. Pods Should Have Low Profile Design For Easy Acss To Any Visibility Of Surgical Field With 1800 C Rotations. 6. It Should Have Iso Certification. , Heart Stabilizing System (Fortheuseofminimal Invasive Cardiac Produre).: 1. It Should Have Low Profile Pods. 2. It Should Have Iso Certification. 3. Suitalbe For Minimally Invasive Cardiac Surgery. , Heart Positioner (Cup Shaped) Archin Variety: 1. Should Be Suction Based. 2. It Should Be Based Low Profile Suction Cup 3. It Should Be Compatible With Various Vogue Cardiothoracic Retractors. 4. It Should Have Low Profile Arm Designed For Better Visualization. 5. It Should Have Iso Certification. , Heart Positioner Starfish Variety: 1. Should Be On Suction Based. 2. It Should Be Based Low Profile 3. It Should Be Compatible With Various Vogue Cardiothoracic Retractors. 4. It Should Have Low Profile Arm Designed For Better Visualization. 5. It Should Have Iso Certification. , Heart Positioner (Fortheuseofminimal Invasive Cardiac Produre).: 1. It Should Be Suction Based 2. It Should Have Low Profile Arm Designed For Better Visualization Micas. 3. It Should Have Iso Certification. , Vascular Graft For Aortic Arch Gelatin / Collagen Coated: 1. It Should Be Coatedwithgelatinor Collagen With Multiple Branches For Arch And Perfusion. 2. Graft Material Should Have Low Porosity Dacron (Fabric) 3. Should Be Provided With Various Sizes 4. It Should Have Iso Certification , Vascular Graft Y Type Gelatin / Collagen Coated: 1. Itshouldbecoatedwithgelatinor Collagen. 2. Graft Material Should Have Low Porosity Dacron (Fabric) 3. Should Be Provided In Sizes Of 16X8mm & 14X7mm. , Vascular Graft Straight Woven: 1. Itshouldbecoatedwithgelatinor Collagen. 2. Graft Material Should Have Low Porosity Dacron (Fabric). 3. Should Be Provided In Various Sizes And Lengths. , Axilo Femoral Ring Graftptfe: 1.Material Should Have Eptfe. 2.It Should Have Rings Forkink Resistan. 3Size-6,7,8Mmx20cm,To 90 Cm , Axilo Femoral Ring Graft Ptfe, Thin Wall.: 1. It Should Be In Various Sizes And Length. 2. Material Should Have Thin Wall Ptfe. 3. It Should Have Rings Forkink Resistan. , Axilo Femoral Ring Graft Ptfe,Thin Wall Coated With Carbon.: 1. It Should Be In Various Sizes And Length. 2. Material Should Have Thin Wall With Carbon Coated Ptfe. 3. It Should Have Rings Forkink Resistan. , Disposable Arrhythmia Ablation Kit: 1. Should Be Based On Radio Frequency 2. It Should Have Separate Pack For Monopolar Pen And Bipolar Devi 3. It Should Have/ Approved , Right Angled Venous Cannula: Singlestagecannulawith90degreeplastictub With Side Holes Size 12-28 Fr , E Ptfesuture Cv0,Cv (2-7) , Fibrin Glue: 2- Polyethylene Glycol Synthetic Sealent 2Ml , Asepto Syringe , Tmouth Piece With Tubing And Chamber: , La Line Central Catheter Size 7.5 Fr Length , Teflon Felt Size 2”*2” , E-Ptfecardiovascularpatch (10*5*0.6) , Double Pressure Transdur: 2 Disposable Pressure Transdur With 2 Flush Devis With Stop Cock With 48”+12” Pressure Tubings
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 12
48.
Railways #11107857 AOC
Supply Of supply, installation and commissioning of set of items for gect/ngld , ns-1: providing and laying synthetic acrylic multi-layer cushioned sports flooring system suit able for outdoor basketball and tennis courts, over prepared base, complete in all respects, comprising the ollowing layers and operations: 1. surface preparation, cleaning and repairs as required 2. application of on e coat of acrylic primer 3. application of one coat of acrylic resurfacer 4.application of three coats of acrylic cushion layer to achieve uniform shock absorption 5.application of two coats of textured base coat for skid resistance 6.application of one coat of non-textured top finish coat of approved make 7.line marking for ba sketball and tennis courts as per international standards with all contractors manpower, materials, machine ry, consumables, tools & plant, staff uniforms etc as per the special conditions and directions of engineer in charge [ warranty period: 30 months after the date of delivery ] ] , ns-2: indoor wooden sports flooring ? badminton court supply, installation, testing and com missioning of world badminton federation (bwf) approved indoor wooden sports flooring system for badmi nton court, complete in all respects, consisting of: 1. top playing surface: 20 mm thick hardwood / teak woo d planks 2.sub-structure: 38 mm thick pine/spruce runners / sleepers 3.shock absorption layer: rubber sho ck pads of approved thickness 4.moisture barrier: polyethylene vapour barrier sheet 5.overall system thick ness: approx. 75?80 mm the flooring shall conform to relevant standards such as en 14904, din 18032-2 a nd bwf international elite grade requirements for shock absorption, friction, vertical deformation and ball bounce. includes fixing, leveling, anchoring, finishing, line marking for badminton court, testing and handin g over complete with all contractors manpower, materials, machinery, consumables, tools & plant, staff uni forms etc as per the special conditions and directions of engineer in charge [ warranty period: 30 month s after the date of delivery ] ] , ns-3 supply and installation of bwf approved high-density pvc badminton sports mat floori ng, movable type, consisting of: a multi-layer pvc with fiberglass mesh reinforcement, double foam backi ng for shock absorption with minimum thickness: approx. 5 mm and surface finish: anti-slip crystal/sand e mbossing with performance characteristics: shock absorption, ball bounce, abrasion resistance, slip resista nce includes rolling, jointing, edge finishing, alignment, court line marking, handling and placing in position complete with all contractors manpower, materials, machinery, consumables, tools & plant, staff uniforms e tc as per the special conditions and directions of engineer in charge [ warranty period: 30 months after t he date of delivery ] ] , b). supplying providing and fixing of movable badminton poles of height 1.55m to 2.24m (adj ustable) with base diameter 30-40 cm made of steel with a weight of 15-25kg [ warranty period: 30 mont hs after the date of delivery ] ] , c)supplying providing and fixing of fixed basketball poles with 20mm acrylic board, ring and net (standard quality 6 round pipe in 3mm thick) [ warranty period: 30 months after the date of delivery ] ] , d) supplying, providing and fixing of tennis court accessories net poles with internal winding with sleeves, indian tennis net, center tape with hook, water removing roller (360 rft), referee stand etc., as per the instructions of engineer in charge [ warranty period: 30 months after the date of delivery ] ] , ns-4 providing and installing artificial polyethylene cricket turf system for box cricket area, c omplete in all respects, comprising: a cricket turf carpet of pile height approx. 15 mm made of pe monofila ment yarn, with pp primary backing and latex secondary backing with the specifications composition pe, st ructure monofilament curl, dtex pe8000, tape thickness 130μm?15μm, tape width 0.8-1.0mm, pile height 15mm?1mm, gauge 3/16 inch, stitches per 10cm 34?1, stitches per m2 71400 ?100, total yarn weight 186 0g/sqm ?10%, primary backing pp + polyester fiber short-staple +, mesh scrim inlay, secondary backing latex, total carpet weight 3100g/sqm ?10%. turf installation using seam tape and pu adhesive suitable for outdoor use includes base preparation, fixing, anchoring, finishing and handing over with all contractors ma npower, materials, machinery, consumables, tools & plant etc as per the special conditions and directions o f engineer in charge [ warranty period: 30 months after the date of delivery ] ] , b)court line marking [ warranty period: 30 months after the date of delivery ] ] , c) side and top safety nets made of uv-resistant polyethylene netting of approved mesh size and thickness, including tying ropes and fixing arrangements [ warranty period: 30 months after the dat e of delivery ] ]
Contract Date: May 19, 2026 Contract Value : 31.79 Lakh
Government Departments No of Bidders 1
50.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
TenderDetail
Loading tenders