View Bid Results For Mass Flow Controller Tenders

We found 400 Bid Results related to mass flow controller tenders. You can find Contractor details who won mass flow controller tenders along with contract details in Bid awards announcements section.

Filters
Stage
337
45
18
Tender Publishing Platform
244
156
State / UT
30
44
42
40
34
31
30
19
16
15
15
14
14
13
10
9
8
8
6
6
5
5
4
3
2
2
1
1
1
1
1
Contract Value
81
203
89
27
Publish Date
0
0
0
0
0
Sector
22
112
47
47
46
30
22
17
15
11
9
8
6
5
5
4
3
3
2
2
2
1
1
Ownership
6
203
69
59
55
6
6
Within keyword
Active filters:
Showing 1–8 of 400 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 2.95 Lakh
Boards / Undertakings / PSU No of Bidders 1
Uttar Pradesh View Result →
2.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 3.49 Lakh
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 2.86 Lakh
Government Departments No of Bidders 3
5.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 3.63 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
7.
Educational and Research Institute #11126923 AOC
Bids Are Invited For Mass Flow Controllers (Q3) Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 1.43 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 6.10 Lakh
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 14.74 Lakh
Government Departments No of Bidders 4
13.
Public Administrative Department #10499862 Price Bid
Tender For Repair Maintenance Of Central Laboratory. Sub Work :- Supply Installation And Commissioning Of Scientific / Civil Engineering Lab Equipments. -Providing, Supplying, Commissioning And Demonstration Of Gi Frame Test Sieves 18” Dia Size:Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 2 50 Mm 3 25 Mm 4 31.5 Mm 5 16.0 Mm 6 12.5 Mm 7 10.0 Mm 8 6.3 Mm 9 Lid & Pan 10 Providing, Supplying, Commissioning And Demonstration Of Brass Frame Test Sieves 200Mm Dia. Size: 90 Mic. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 11 Providing, Supplying, Commissioning And Demonstration Of Brass Frame Test Sieves 200Mm Dia. Size: 500 Mic Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 12 Providing, Supplying, Commissioning And Demonstration Of Shrinkage Bar Mould Single Gang Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 13 Providing, Supplying, Commissioning And Demonstration Of Le Chatelier Mould, ( Set Of 6Pc ) Standards:Is 269, 712, 5514, 1727 , 2645, 6932 ( Part Ix ) Bs 6463Specification: It Consists Of A Small Split Cylinder Forming A Mould. On Either Side Of The Split Cylinder. Two Parallel Indicating Arms With Pointed Ends Are Attached. Supplied Complete With Two Glass Plates And A Lead Weight. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 14 Providing, Supplying, Commissioning And Demonstration Of Le Chatelier Water Bath Double Walled Inner Chamber In Stainless Steel Outer Chamber In Mild Steel Temperature Range Ambient To 100°C Controlled By Capillary Thermostat. Accuracy ± 1°C Operated On 230V A.C. Single Phase. These Baths Are Suitable For Washing Marshall Specimen. Lid Is Made Up Of Stainless Steel With A Hole For Glass Thermometer To Penetrate. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 15 Providing, Supplying, Commissioning And Demonstration Of Vicat Needle Apparatus With Dashpot With Mtcspecification:The Apparatus Consists Of A Metallic Frame Bearing A Freely Movable And With A Cap At Top, One Vicat Mould And Glass Base Plate And One Set Of Needles One Each Initial Needle, Final Needle And Consistency Plunger. It Comes With A Dashpot Which Facilities Gentle Lowering Of The Needles. Accessories : Mild Steel Base Plate 5 Inches X 5 Inches. Fulcrum Mould , Brass , 80 Mm I.D. Base Dia X 70 Mm I.D. Top Dia , 40 Mm Height. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 16 Providing, Supplying, Commissioning And Demonstration Of Specific Gravity And Water Absorption Of Aggregates Model With Nablcalibration Certificate Standards: Is 2386 ( Part Iii ) & Bs 812Specification: The Buoyancy Balance System Consists Of A Rigid Support Frame, Incorporating A Water Tank Mounted On A Platform. A Mechanical Lifting Device Is Used To Raise The Water Tank Through The Frame Height Immersing The Specimen Suspended Below The Balance. The Balance Supplied May Also Be Used As A Standard Weighing Device, Thus Providing A Versatile And Comprehensive Weighing System In The Laboratoryspecification:The Outfit Comprises Of• Electronic Balance, Capacity 15 Kg. Least Count 0.5Gm, Provision Is Made In This Balance To Suspend Density Basket Under Material Pan. This Balance Is Mounted On An Angle Iron Frame Stand. 1 No• Density Basket. 1 No• Air Tight Container To Suspend Density Basket. 1 No• Gi Tray Of Area Not Less Than 650 Cm Sq. 1 No.• Absorbent Cloths 75Cm X 45Cm. 2 Nos. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 17 Providing, Supplying, Commissioning And Demonstration Oflos Angeles Abrasion Testing Machine With Nablcalibration Certificate Standards: Is 2386 ( Part Iv ) Astm C 131, Aashto T-96Specification:The Machine Consists Of A Hollow Cylinder Mounted Horizontally On A Study Frame On Ball Bearings. There Is An Opening Which Can Be Closed With A Dust Tight Cover To Facilitate Charging And Discharging The Drum With The Material Under Test. A Detachable Shelf Which Extends Throughout The Inside Length Of The Drum Which Catches The Abrasive Charge And Does Not Allow It To Fall On The Cover. The Drum Is Rotated By An Electric Motor Through A Heavy Reduction Gear At A Speed Of 30-33 R.P.M. A Revolution Counter Is Fitted To The Frame. A Tray Is Supplied For Collection Of The Material At The End Of The Test. Complete With Abrasive Charge Consisting Of A Set Of Twelve Hardened Steel Balls, Approximately 48Mm Dia. Suitable For Operation On 440 V, 3 Phase, 50 Cycles, A.C. Supply Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 18 Providing, Supplying, Commissioning And Demonstration Of Electrical Oven Doublewall For Soil Inside Chamber In Ss Outside Mild Steel With Digital Temperaturecontroller Along Withblower With Circulation The Airambient Temperature With Two Tray 2500Csize: 18”X18”X18” With Nablcalibrationmake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 19 Providing, Supplying, Commissioning And Demonstration Of Digital Double Door Oven Zi Model No : 9014225 Liter Cap. , Temp. Amb. To 250 Degree C Or Equivallent Specificationthis Range Of Ovens Is Designed For Drying Large Quantities Of Soil And Aggregate Samples And Maintains Temperature In Accordance With Most B.S. And Astm Requirements.The 225 Lts. Are Economy Models Constructed With Coated Mild Steel Exterior And Stainless Steel Coated Interior Chamber, Which Is Both Durable And Corrosion Resistant.These Units Meet The Requirements Of Bs 1377 And Are Ideal For On-Site Laboratories And General Soil And Aggregate Testing. Options And Accessories:• Dial Thermometer With Collar Fixing For Door• Heavy Duty Shelves ( On Request At An Extra Price ) • Color Of The Oven ( Only On Qty. Greater Than 3 Units ) Specifications:• The Larger Soil Drying Ovens Are Constructed With Mild Steel And Powder Coated Exterior And Stainless Steel Coated Chamber Which Is Both Durable And Corrosion Resistant.• All Sizes Of Oven Are Fitted With A ( Pid Controller ) Having A Microprocessor Digital Control As Standard.• All Units Comes With Mcb Tripping Device In Cases Of Any Short Circuit, Overloading Of Voltage And Low Voltage Cut Off. Wiring Of Heaters Can Be Connected / Dis-Connected Removing The Side Panels Of The Oven. 20 • Caster Wheels With Locking Arrangement Are Fitted Below The Oven For Easy Movability Of The Unit From One Place To Another. Door Locking Arrangement Is Very Easy Convenient With Lever To Lock Unlock With Half Turn Lever• A Safety Thermostat Is Fitted Inside The Oven For Safety Purpose. Incase Of The Failure Of The Pid Controller The Safety Thermostat Will Serve As The Temperature Controller.• A High / Low Switch Is Fitted On The Panel Of The Oven For Heaters. This Feature Allows Heaters To Burn All Together Or Half Of Them.• The Least Count Division For Viewing / Setting The Temperature Is 0.1º C Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 21 Providing, Supplying, Commissioning And Demonstration Of Standard Compaction Test ( Is ) Standards: Is 2720 ( Part-Vii ) Specification: Instrument Consists The Apparatus Consists One Each Of Compaction Mould Mild Steel, 100 Mm I.D. X 127.3Mm Height X 1000 Cc Volume, Complete With Collar And Base Plate.Compaction Rammer Is 2.6 Kgs In Weight X 310Mm Controlledfall Make Aimil / Lawrence & Mayo / Lynx / Enkay / Zeal International Enterprises. 22 Providing, Supplying, Commissioning And Demonstration Of Heavy Compaction Test ( Is ) Standards: Is 2720 ( Part-Viii Specification:Instrument Consists One Each Of Compaction Mould Mild Steel 150 Mm I.D. X 127.3Mm Height Volume 225°C. Complete With Collar And Base Plate. Compaction Rammer Is 4.89 Kgs. In Weight X 450 Mm Controlled Fall. Note : Instead Of Steel Moulds, Gunmetal Mould Are Also Available Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 23 Providing, Supplying, Commissioning And Demonstration Of Sand Pouring Cylinder – Is, Standards: Is 2720 ( Part Xxviii ) 1966Specification: This Apparatus Is Used For The In Place Determination Of The Dry Density Of Compact, Line And Medium Grained Soils And For Layers Not Exceeding 500Mm Thickness. The Complete Apparatus Consists One Each Of Small Sand Pouring Cylinder, 3 Litre Capacity Fitted With Conical Funnel And Shutter. Cylindercalibrating Container, Internal Dia 100Mm And 150Mm Height.Accessories:Metal Tray, 300Mm Square And 40Mm Deep With Hole Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 24 Providing, Supplying, Commissioning And Demonstration Of Liquid Limit Apparatus Hand Operated With Mtcspecification:Casagrande Method In Mechanical Form Is Known As Liquid Limit Method And Has Been In Use For Soil Mechanics For A Number Of Decades. The Liquid Limit Data Of Soils Is Useful To Correlate Mechanical Properties Of Soil, Such As Compressibility And Lower Shear Strength. Liquid Limit Is The Water Content At Which Soil Passes From Zero Strength To An Infinite Strength, Hence The True Value Of Liquid Limit Cannot Be Determined. For Determination Purpose Liquid Limit Is That Water Content At Which A Part Of Soil, Cut By A Groove Of Standard Dimensions, Will Flow Together For A Distance Of 1.25Cm Under An Impact Of 25 Blows In A Standard Liquid Limit Apparatus. The Soil At The Water Content Has Some Strength Which Is About0.17N / Cm. Sq. ( 17Gms / Sq.Cm. ) . At This Water Content Soil Just Passes From Liquid State To Plastic State.It Consists On A Brass Cup Held On An Adjustable Bracket.The Cup Can Be Adjusted For A Fall Of 1 Cm And Can Be Raised An Dropped On A Rubber Base Of Standard Hardness By Cam Action. Complete With One Casagrande Grooving Tool, One Astm Grooving Tool And A Height Gauge Block. A Counter To Register The Number Of Blows.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 25 Providing, Supplying, Commissioning And Demonstration Of Aggregate Impact Test Machine With Counter, Mould And Steel Rod 16 Mm Dia. 26 Providing, Supplying, Commissioning And Demonstration Of Plastic Limit Set Model Is 2720 ( Part-Vii ) Astmd-42, Bs 1377 Aashto T 90Moisture Contents At Which Soil Has Smallest Plasticity Is Called Limit. For Determination Purpose Plastic Limit Is Defined As The Water Content At Which A Soil Will Just Begin To Crumble When Rolled In To A Thread Of 3Mm Dia.Specification:The Complete Set Consists Of One Each :1. Glass Plate 20Cm X 15Cm Having Round Ends2. Brass Or Stainless Steel Rod 3Mm Dia X 150Mm Long3. Flexible Spatula 15 Cm4. Set Of 6 Moisture Containers5. Porcelain Basin 150Mm Dia6. Plastic Wash Bottle 500Ml Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 27 Providing, Supplying, Commissioning And Demonstration Of Digital California Bearing Ratio Test Apparatus ( Cbr ) Standards: Is 9669, Is: 2720 ( Part Xvi ) With Nablcalibration Certificate The Lab Test Is Designed For Performing Laboratory Evaluation Of The Cbr Value Of Highway Sub Bases And Sub Grade And For The Determination Of Strength Of Cohesive Materials Which Have Maximum Particle Sizes Less Than 19 Mm ( 3 / 4” ) . The Machine Is Designed To Be Mounted On A Suitable Bench And Comprises Of A Robust And Compact Two Column Frame With Adjustable Upper Cross Beam. The Frame Is 50 Kn Capacity. Three Test Speeds Are Provided 1.25 Mm / Min, 1.50 Mm / Min & 2.5 Mm / Min Tests. This Main Feature Allows The User To Perform Tests. Laboratory California Bearing Ratio Apparatus With Software & Pc Interface. Zi 3066A Three Speed Load Frame, 50Kn ( 5000 Kgf ) Capacityzi 3066B Mould 150Mm Id X 175Mm Highzi 3066C Perforated Base Plate For Zi3074- 2 Mouldzi 3066D Extension Collar, 150Mm Id X 50Mm Highzi 3066E Penetration Piston, 50Mm Face Diazi 3066F Adjustable Bracket, For Penetration Dial Gaugezi 3066G Circular Metal Spacer Disc. With Detachable Handle 148 Mm Dia X 47.7 Mm High Time.Zi 3066H Annular Metal Weight, 2.5Kg, 147Mm Dia With 53 Mm Dia Central Hole 28 Zi 3066I Perforated Metal Weight 2.5 Kg. 147Mm Dia, With 53Mm Dia Softzi 3066J Perforated Plate, 148Mm Dia, With Adjustable Stem And Lock Nutzi 3066K Metal Tripod For Dial Gaugezi 3066L Cutting Collarzi 3066O S Type Load Cellcapacity 50 Knzi 3066P Lvdt, 25 Mm Travel, 0.01Mm Least Count Optional Extras:Salient Features:-• No Need Of Separate Observation On Dial Gauge And Proving Ring.• Facility To Readout Rate Of Loading In Mm / Minute.• Tare System To Nullify Initial Load The Digital Lcd Display Will Retain The Peak Value Until It Is Cleared.• Flow Value And Load On A Single Screen.• Flow Value With A Least Count Of 0.01 Mm With Accuracy Of 1%.• Load Value With A Least Count Of 0.1 Kg / 0.001 Kn With Accuracy Of 1%.• Back Light Facility To Observe The Readings Even In The Dark.• Two Line Readout Showing Load, Flow, And Speed.• Software Interface To Pc And Plot Live Graph. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises 29 Providing, Supplying, Commissioning And Demonstration Of Shrinkage Limit Set Standards:Is 2720 ( Part-V ) Astm D 427, Bs 1377, Aashto T 92.Specification:Shrinkage Limit Is The Maximum Water Content At Which A Reduction In Water Content Does Not Cause An Appreciable Reduction In Volume Of The Soil Mass. At Shrinkage Limit, On Further Reduction In Water, Air Enters In To The Voids Of Soils And Thus Keeps The Volume Constant.The Apparatus Can Be Used To Determine Shrinkage Limit And To Calculate Other Shrinkage Ratio, Shrinkage Index And Volumetric Shrinkageset Consists Of One Each:1.Porcelain Evaporating Dish2.Shrinkage Dish3.Glass Cup4.Perspex Plate With Three Metal Prongs5.Flexible Spatula 100Mm6.Glass Cylinder7.25Ml X 1Ml, Supplied Without Mercury8.Plastic Wash Bottle 500Mlmake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 30 Providing, Supplying, Commissioning And Demonstration Of Enamel Tray Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 31 Enamel Tray 10 X12” 32 Enamel Tray 12” X18” 33 Enamel Tray 18” X24” 34 Providing, Supplying, Commissioning And Demonstration Of Triaxial Test Apparatus Electrical With 10 Kn Load Cell And 25 Mm X 0.01 Lvdt , 2 Channel Data Acquisition System And Software Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. ( Rates Included Sub Head A To D ) 35 Providing, Supplying, Commissioning And Demonstration Of Load Frame, Motorised, 3 Speeds With Dial Gauge Features: · Two Pillar Type ·Detachable Frame ·Enclosed Motor And Gear System · Jewel Lamps Indicating Direction Of Motion · Operational Ease · Useful For Triaxial And Cbr Tests The Load Frame Consists Of A Cabinet Which Houses The Gear System And Motor With Sturdy Angle Iron Frame. The Loading Is Done Through The Bottom Loading Platen, Which Is Carried On A Lead Screw, Which Advances Upwards. The Top Load Bracket, Which Slides Over Two Upright Pillars, Can Be Positioned At Any Desired Height And Locked. It Carries A Screw Adapter For Standard Proving Rings And Load Cells. The Loading Part Of The Unit Is Detachable From The Main Unit For Ease Of Transport And To Avoid Damage To The Tension Rods. Rates Of Strain: 6 Fixed Speeds 1.25, 1.50, 2.50 Mm / Min. Suitable For Operation On 230 V, 50 Hz, Single Phase, Ac Supply Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 36 Providing, Supplying, Commissioning And Demonstration Of Lateral Pressure Assembly 10Kg / Cm² It Is Designed For Application Of Cell Pressure Upto 10Kg / Cm2 On A Triaxial Specimen In The Triaxial Cell. The Unit Is Mostly Used In Routine Tests Which Last For About 10 To 15 Minutes Wherein The Variations Of Cell Pressure Can Be Tolerated.Specification :The Apparatus Consists Of A Pressure Chamber Which Has A Flanged Top Cap Fitted With A 10 Kg / Cm2. Pressure Gauge And A Valve For Pumping In Air. Water Inlet And Drain Cock Are Fitted To The Chamber. The Foot Pump Supplied Easily Develops A Pressure Of 10 Kg / Cm2 Complete With Connecting Pressure Hose.Note: Also Available 20Kg / Cm2 Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 37 Providing, Supplying, Commissioning And Demonstration Of Triaxial Cell For 38 Mm Dia The Accessories & Foot Pump Specification:The Cell Is Useful For Testing 38Mm Dia X 76Mm High Soil Specimen. Transparent Perspex Chamber With Anvil And Loading Plunger, The Cell Is Easily Opened By Releasing Four Nuts Of The Tie Rods. It Is Leak Proof Up To 10Kg / Cm.Sq. Fluid Pressure. An Oil Plug Which Can Also Be Used As An Air Vent Is Provided For Introducing A Thin Layer Of Oil Over Water. This Provides Effective Sealing At The Plunger For Long Duration Tests. The Cell Is Fitted With Four Sleeve Packed Valves Of No Volume Change Type On The Base. These Valves Are Used For Cell Pressure, Pore Water Pressure, Drainage Or Back Pressure. The Loading Plunger Of The Cell Has Dial Gauge Rest.•Loading Pad Made Of Perspex For 38Mm Dia Specimens.•Pair Of Plain Discs Made Of Perspex 38Mm Dia 6Mm Thick.•Pair Of Porous Stones 38Mm Dia Specimen.•Split Sand Former For 38Mm Dia Specimen.•Sheath Stretcher For 38Mm Dia Specimen.•One Dozen Rubber Sheaths For 38Mm Dia Samples.•For Synthetic Rubber ‘O’ Rings For 38Mm Dia Specimen.•One Plastic Drainage Tube. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 38 Providing, Supplying, Commissioning And Demonstration Of Pore Pressure Apparatus 10 Kg / Cm² Specification: The Apparatus Consists Of A Panel For Wall Mounting On Which Are Fitted 1.0 To 10Kgmanom / Cm Sq X 0.1Kg Cm. Sq. A Pressure Gauge, Bourdon Tube Type 15 Cm Diameter: Glass U-Tube Manometer For Measuring Low Positive Pore Pressures Negative Pore Measures And Checking Zero Error Of Pressure Gauge. It Is Provided With A Mercury Trap ( Mercury Supplied At Extra Cost. ) Null Indicator Made Out Of Clear Transparent Perspex With Mercury Trap And Cursor To Indicate The Mercury Level. Burette: 50Ml Burette For Measuring The Volume Change In The Soil Specimen. Pressure Pump Fitted With Four Sleeve Packed Valves, Operated By Means Of A Hand Wheel On The End Of The Piston Rod Which Is Threaded Through The Pump Cap And Gives A Smooth, Fine Adjustment Of Pressure. Copper Coil And Water Reservoir Is Fitted On Board With Complete Stand Assembly. The Unit Is Tested Against Leaks Up To 10Kg / Cm Sq.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 39 Providing, Supplying, Commissioning And Demonstration Of Ring & Ball Apparatus ( Semi Automatic ) Model No. Zi 4003Ref. Standards - Is:1205, Astm D 36, E 28, Ip 198, Ip 58, Aashto T53, Bs:2000, En 1427 With Nablcalibration Certificate For Determining The Temperature At Which A Sample Of Bituminous Material Loaded By A 9.5 Mm Dia Steel Ball, Drops A Specified Distance When Heated Under Specified Conditions.Ring And Ball Apparatusthe New Design Of Ring And Ball Apparatus Is Compact User Friendly And Has Better Aesthetics. It Has Magnetic Stirrer With Heating Facility And Digital Display Of Temperature, The Heating Can Be Adjusted Through Knob.Suitable For Operation On 220 V, 50 Hz, Single Phase, Ac Supply. Each Unit Is Supplied With A Bath Of Heat Resistant Glass And Thefollowing:Zi 4003-A Tapered Rings 2 Nos.Zi 4003-B Ball Centering Guide 2 Nos.Zi 4003-C Steel Balls Of 9.5 Mm Dia 2 Nos.Zi 4003-D Ring Holder 1 No.Zi 4003-E Electric Heater ( Hot Plate ) 1 Nos. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 40 Providing, Supplying, Commissioning And Demonstration Of Marshall Stability Test Apapratus Model No : Zi – 4022 Or Equivalentastm : D 1559 T-62 Bs 598-107 With Nablcalibration Certificate Marshall Apparatus Consists Of:• Robust Construction• 50Kn Capacity• Rate Of Travel 50.8Mm / Min• Safety Cut-Off Switchit Consists Of Body Housing, A Geared Screw Jack And Motor Drive Mechanism Suitable For Operation On 230 V, 50Hz, Single Phase, A.C. Supply.Zi 4022-A Marshall Load Frame 1 No.Zi 4022-B Breaking Head Stability Mould, 100Mm Mm With A Dial Gauge ( Having 25Mm Travel And 0.01Mmleast Count ) , For Flow Measurement 1 No.Zi 4022-C Compaction Mould, Steel Cylindrical 100Mm3 Nos.Zi 4022-D Base Plate 3 Nos.Zi 4022-E Extension Collar 3 Nos.Zi 4022-F Compaction Pedestal, 100Mmmanual Operation, Comprising A Steel Plate Capped On A Wooden Post. A Mould Clamp Is Fitted To The Top Of The Plate . 1 No.Zi 4022-G Compaction Hammer, 100Mmsatisfies Bs 598. The Hammer Has A 4535 G Sliding Weight With A Free Fall Of 457 Mm 2 Nos.Zi 4022-H Load Transfer Bar 1 No.Zi 4022-I Paper Discs, Non Absorbent, 11 Cm Diameter Pack Of 100 No. 1 Pkt.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 41 Providing, Supplying, Commissioning And Demonstration Of Marshall Mould Complete With Collar & Base Plate 100Mm Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 42 Providing, Supplying, Commissioning And Demonstration Of Centrifuge Extractor Motorised, Zi 4014 Or Equivalentstandards:Astm D2172 Aashto T-58, T-164Specification:Centrifuge Extractor, Electrical Operation, Capacity 1500G, With A Dimmer Stat For Speed Control From 2, 400 To 3, 600 Rpm. Suitable For Operation On 230 V, 50 Hz, Single Phase, A.C. Supply Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 43 Providing, Supplying, Commissioning And Demonstration Of Ductility Testing Apparatusdigital Aimil Type Model No. Zi – 4025Or Equivalent With Nabl Calibration Certificatestandards:Is 1208-1058, Astm D 113, Ip32, 55, Aashto T 51Specification:Designed To Test Three Specimens Simultaneously. The Machine Consists Of A Carriage Moving Over A Lead Screw. An Electric Motor Driven Reduction Gear Unit Ensures Smooth Constant Speed And Continuous Operation. The Entire Assembly Is Mounted With A Stainless Steel Lined Water Bath Completely Encased In Metal Bound Hardwood. It Is Equipped With An Electric Pump Circulator And Heater. The Temperature Is Controlled Thermostatically. Two Rates Of Travel I.E. 50 Mm / Min And 10 Mm / Min Are Provided. Suitable For Operation On 230 V, 50 Hz, Single Phase, A.C. Supply. Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 44 Providing, Supplying, Commissioning And Demonstration Of Standard Digital Penetrometer ( Made In Italy ) Used To Determine The Consistency Of A Bituminous Sample Under Fixed Conditions Of Load, Time And Temperature. The Penetration Is Expressed In Distance Of Tenths Of Millimeters Vertically Penetrated By A Standard Needle. The Standard Penetrometer Is Ruggedly Constructed, With An Aluminium Base Table With Levelling Screws, Platedvertical Rod, “Micrometric Vertical Adjustment Device”.The Slider Is Brass Made With Free Fall.The Digital Readout Of The Penetration Values Has Readings In Mm And Inch, With 0.01 Mm Resolution, Lcd 5 Digits Display, With Zero Set In Any Position.Power: 1.5V Battery.The Penetrometer Is Supplied With Stop And Release Push Button, Automatic Zero Set, Micrometer Adjustment, Set Of Weights 50 And 100 G Penetration Needle, Brass Sample Cups Diameter 55X35 Mm And 70X45 Mm.Dimensions: 220X170x410 Mmweight: 11 Kg Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 45 Providing, Supplying, Commissioning And Demonstration Of Digital Penetrometer Zi 4008 Or Equvalentstandards: Is 310, 1203, 1448, Ip 60, 49, 50 Astm D5, 217, D637, Bs 2000-49Specification: Same As Zi 4007 But The Unit Is Compact With Timer To Control Duration Of Penetration. The Instrument Is Provided With Lead Screw Gear Arrangement, Leveling Screws, Spirit Level And A Digital Preset Timer Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 46 Providing, Supplying, Commissioning And Demonstration Ofstripping Value Apparatus, Zi 4012 Or Equivalent Make With Standards: Specification:A Circular Tray Rotates In A Vertical Plane At A Rate Of Approximately 100 R.P.M. By An Electrical Geared Motor. 4 Bottles Of Approximately 400 Cc Are Mounted On This Circular Tray At An Angle Of 900. To Each Other With Their Mouth Towards Center Of The Tray. A Time Switch Is Provided. Suitable For Operation On 230 V A.C. Single Phase.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 47 Providing, Supplying, Commissioning And Demonstration Of Core Cutting / Core Drilling Machine ( Petrol ) Model Nozi 6001 With 100Mm Core Bit Or Equivqlent Makespecification:Suitable To Cut / Drill Cores Of Concrete, Rocks, Stones, Tiles Or The Similar Materials. The Machine Is Suitable For Core Samples Of Size Upto 150Mm Diameter With The Help Of Thin Walled Diamond Bits Which Are At Extra Cost. The Machine Has Sturdy Base With Pillar Support In Which Rack And Pinion Is Provided For Adjustment In Height And Penetration Assembly. The Leveling Screws Are Provided At The Base. For Gripping The Sample In Position Suitable Grips Are Provided. A Suitable Petrol Engine Is Fitted In The Machine With Cooling Arrangement With Water. The Base Frame Is Also Fitted With Wheels For Ease Of Transportation.Dimension Approx, Are As Under:Height: 1300 Mmbase: 625 X 900 Mmhead Travel On Rack: 500Mmdrill Speeds : 900 R.P.M. For Soft Samples And 350 R.P.M. For Hard Sampleswater Swivel : Built In The Machines.Accessories: ( 1 ) Thin Wall Diamond Bits. ( 2 ) Core Barrel. ( 3 ) Petrol Engine Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 48 Providing & Supplying Core Bit 4 Made In Germany : Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 49 Providing & Supplying Core Bit 6 Made In Germany : Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 50 Providing, Supplying, Commissioning And Demonstration Of Absolute Viscometer Bath Zi 4017 Or Equivalentspecification:This Bath Is Designed And Developed Under The Strict Supervision Of Our Experienced Professionals In Accordance With The International Quality Standards. Our Offered Bath Is Thoroughly Checked On Various Parametersto Ensure Zero-Defect. This Bath Is Widely Used In National Laboratories And Pharmaceutical Industries.Features:•Intelligent Signal Sampling For Accurate Data Measuring And Parameter Reading•Accurate Viscometer For Improving Experimental Efficiency•High Precision Digital Display•Ideal For Controlling The Temperature Accuracy•Durable Glass Bath For Optimum Heat Preservation•Desktop Based All-In-One Design For Easy Operations And Portability•Electric Stirrer For Ensuring Uniform Temperature Of Bath•Easy Cleaning And Drying Of Viscometer Tubesother Information:The Accompanying Absolute Kinematic Viscosity Bath Are Utilized To Measure Supreme Thickness Of Consistency Reviewed Clearing Bitumen ( Is:73:2006 ) At 160°C As Per Is:1206 ( Part Ii ) ( Like Astm D 2171 ) , Which Utilizes A Vacuum Slender Viscometer. Complete Absolute Viscosity Testing Equipment Adjusting To Is: 1206 ( Part Ii ) Method For Testing Tar And Bitumen Materials: 51 Determination Of Absolute Viscosity With The Accompanying Segments:Consistent Temperature Bath – A Suitable Shower For Drenching Of No Less Than 2 Vacuum Fine Viscometer Tubes With A Computerized Temperature Controller. The Precision Of The Temperature In The Shower Will Be + 0.1Oc All Through The Showermake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 52 Providing, Supplying, Viscosity Tube For Absolute Viscometer Bath With Calibration Certificate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 53 Providing, Supplying, Commissioning And Demonstration Of Flash Point ( Closed ) Pensky-Martens Apparatusspecification:For Determining The Flash Point Of Fuels Oil And Lubricating Oil, Bitumen Other Than Cutback Bitumen And Suspension Of Solids In Liquids, Having A Flash Point Above 49ºc.Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 54 Providing, Supplying, Commissioning And Demonstration Of Standard Tar Viscometer Specification:For Determining The Viscosity Of Cut Back Bitumen And Road Oil. The Viscometer Consists Of A Chrome Plated Copper Bath, With A Drain Valve And A Central Tube To Receive The Test Cup And To Position The Stirrer, And Is Mounted On A Stand With Levelling Feet. Stirrer Has A Curved Shield And Is Provided With An Insulated Handle, Thermometer Socket And Swivel Support For The Valve Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 55 Providing, Supplying, Commissioning And Demonstration Of Temperature Controller With Nablcalibration Certificate Size : 16X12x10”Standards Specification:Double Walled Inner Chamber In Stainless Steel Outer Chamber In Mild Steel Temperature Range Ambient To 100° C Controlled By The Capillary Thermostat. Accuracy ± 2° C, Least Count ±0.1° C.& Fhp Motor Cum Stirrer. Operated On 230V A.C. Single Phase. Heaters Are Provided According To The Size Of The Chamber. A Control Panel In Which The Digital Controller, Switches For Mains, Fhp Stirrer, A Regulator For The Stirrer Is Fit Is By The Side. These Baths Are Suitable For Washing Marshall Specimen. The Lid Is Made Up Of Stainless Steel With A Hole For Glass Thermometer To Penetrate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 56 Providing, Supplying, Commissioning And Demonstration Of Tile Abrasion Testing Machine Is 1237 This Is Used For Determination Of Resistance To Wear For Cement Concrete Flooring Tiles. Tiles Specimen Of Size 7.06 Cm X 7.06 Cm Is Pressed Face-Wise Under Specific Load On A Grinding Path And Abrasive Powder Is Evenly Spread On The Rotating Grinding Disc The Second Parallel Side Of The Tile Is Subjected To Wear For Similar Number Of Rotations. The Wear Of The Tile Is Measured On A Thickness Gauge Specifically Made For The Purpose. The Machine Consists Of A Disc Rotating At A Speed Of 30 R.P.M. In A Circular Tray. A Bracket Is Provided To Hold The Specimen. A Counter Balance Lever Loads The Specimen. Load Applied Is 30 Kgf. A Funnel Is Fitted To Evenly Spread Abrasive Powder On The Grinding Path. A Pre-Set Counter Automatically Stops The Machine After 22 Revolutions. This Counter Is Re-Adjustable. The Machine Works On 440 V A.C. Three Phase Electrical Supply. On Request Machine To Operate On 230 V A. C. Supply Can Also Be Suppliedmake Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 57 Providing, Supplying, Commissioning And Demonstration Of Hot Plate ( Rectangular ) Rectangular Hot Plate With Outer M.S. Sheet Body Duly Powder Coated Stove Painted To Work On 230 V Ac Supply. Useful For Continuous Heating Up To 300° C. Heavy Duty Cast Iron Top With Heat Resistant Paint. Hot Plate Size Rating 12 X 14 X 6Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 58 Providing, Supplying, Commissioning And Demonstration Of Digital Thermometer With Nablcalibration Certificate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 59 Providing, Supplying, Commissioning And Demonstration Of Infrared Thermometer With Nablcalibration Certificate Make Aimil / Lawrence & Mayo / Lynx / En Kay / Zeal International Enterprises. 60 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 600 Gm Capacity Accuracy 0.01 Gmdual Display Battery Cum Electrically Operated With Calibration Certificate. 61 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 1000 Gm Capacity Accuracy 0.01 Gmdual Display Battery Cum Electrically Operated With Calibration Certificate. 62 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 5 Kg Capacity Accuracy 0.1 Gm Dual Display Battery Cum Electrically Operated With Calibration Certificate. 63 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 30 Kg Capacity Accuracy 2 Gm Dual Display Battery Cum Electrically Operated With Calibration Certificate . 64 Providing, Supplying, Commissioning And Demonstration Of Electronic Balance Upto 100 Kg Capacity Accuracy 10 Gm Dual Display Battery Cum Electrically Operated With Calibration Certificate. 65 Providing, Supplying, Zi 4014-A Filter Paper Discs, Set Of 25 66 Providing, Supplying, Commissioning And Demonstration Of Laboratory Cement Autoclave Zi 1016 Or Equivallentstandards:Is 4031-1968, Is 1624-1960 & Astm C 151, C 141Specification:The Autoclave Is Suitable For Conducting Accelerated Soundness Tests On Cements Or The Autoclave Expansion Test Requiring Constant Steam Pressure With The Correspondent Constant Pressure. It Consists Of A Stainless Steel Cylinder With A Welded Heat Insulated Metal Housing Attractively Finished. The Attached Control Unit Encloses A Sensitive Pressure Regulator And Pressure Gauge. Power Switches And Pilot Lights For Controlling The Electric Heating Units. Inside Chamber Dimensions 15.0 Cm Diameter X 40.5Cm Height Suitable For Operation On 230 V, 50 Hz Single Phase A. C. Supply. Supplied Complete With Test Bar Holder, Special Rack To Hold Specimens Above Water Level In The Autoclave And In A Vertical Position To Expose Them In The Same Manner. A Digital Pid Controller Is Fitted For Controlling The Desired Temperature. 67 Providing, Supplying, Auto Clave Mould 282 X25x25 Mm As Per Is Or Equviallent Make. 68 Providing, Supplying, Zi 2027A50 Mm Plastic Abs Cube Mould 69 Providing, Supplying, Zi 2027B70.6 Mm Plastic Abs Cube Mould 70 Providing, Supplying, Zi 2024B Cube Mould ( Cast Iron - For Mortar ) 50Mm, Three Gang As Per Is Or Equviallent Make. 71 Providing, Supplying, Zi 2024C Cube Mould ( Mild Steel - For Cement ) 70.6Mm, With Loose Base Plate As Per Is Or Equviallent Make. 72 Providing, Supplying, Commissioning And Demonstration Ofaccelerated Curing Tank With Cooling Arrangement Zi 2045B Or Equvallentstandards:Specification:Curing Tank Or Concrete Curing Tank Is Used For The Curing Of Concrete Samples For At Least 8 Hours. The Purpose Of Curing Is To Ensure That All Concrete Samples Are Similar With Regards To Quality And Strength.24 Hour Cycle From Time Of Mixing.Controlled 35° C Or 100° C ± 2° C Curing Temperature For Concrete.Controlled 27° C ± 2° C Curing Temperature For Grey Cement.This Curing Tank Has Been Designed To Accommodate 150Mm / 70.6Mm Cube Moulds And Upto 12 / 24Cube Mould Can Be Cured In One Go. The Tank Is Fully Insulated, Comes Complete With A Hinged Lid, Heater, Thermostat And Re-Circulated Pump. Provision Of Two Removable Racks Allows Free Circulation Of Water Around Each Mould. The Pump, Drain Valves And Electrical Equipment Are Housed In A Compartment Located At One End Of The Tank. The Tank Is Heated By An Immersion Heater Under Normal Conditions And Refrigeration System For Grey Cement The Temperature Is Controlled At 35° C Or 100° C ± 2° C / 27° C +2° C, Expect For The 15 Minutes After Immersion Of The Freshly Made Specimens. Accelerated Curing Tank With Cooling Arrangement Is Also Available. 73 Providing, Supplying, Commissioning Of Fridge 407L 3 Star Frost-Free Digital Inverter Double Door Refrigeratorconvertibleof Make Samsung / Lg / Whirlfool Etc 74 Carriage Of Materials From Chennai Port To Port Blair Central Lab ( As The Quottation Given By Zeal Internatiol Up To Chennai Port )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Andaman And Nicobar Islands View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
15.
Communications and Information Technology  #10457552 Price Bid
Supply Installation Testing Commissioning And Equipment For Gold Ornament Cluster Supply, Installation, Testing, Commissioning And Trail Run Of Machinery And Equipment For Gold Ornament Cluster Under Mse Cdp Scheme. , Gold Cluster Ornament , Supply And Installation Of Faceting And Milling Machine (Cnc Machine) For Bangles And Wedding Bands Double Head With Variable Speed Control, Computerizes Six Axis System. Specification: Number Of Head Horizontal & Vertical 02. Type Of Main Centre Universal 03. Number Of Axis (5+2) ‘X Longitude, ‘W D-Tilting, ‘Z Vertical For Depth, ‘R 360° Horizontal Rotary For Angular Position & Machining, ‘H Horizontal Spindle, ‘V Vertical Spindle, 04. Travel Of Axis ‘X Longitude 60 Mm, ? Rotating For Job - Continuous Rotary/Index, 2 To 400 Divisions, ‘W Tilting (Semi Rotary) Degree -40° To 90°, 05. Type Of Optional Accessories For Optimum Operation. Optional Accessories Can Be Fitted For Flat And Half Round Bangles And, Bands (Rings) 06 Milling Spindle Speed Horizontal (Servo Motor) Vertical (Hf Ac Built-In Motor With Pneumatic Tool Change Water Cooled Spindle). Min. 1000 Rpm To Max. 9000 Rpm, Min. 10,000 Rpm To Max. 60,000 Rpm ‘? Rotary,07. Spindle Motor Power Vertical, Horizontal, 1.5 Kw, 0.4 Kw,08. Electrical Supply 220V Ac / 50 Hz, 09. Total Required Electrical Load 3 Kva, 10. Air (Pneumatic) Supply Dry And Oil Free Air With 6 Bar / 87 Psi And 4 Cfm /120 Lpm Flow Rate, 11. Dimension (L X W X H) 94 X 97 X 156 Cm. 37 X 38 X 61 Inch.12 Floor Space Required (L X W X H) 155 X 161.5 X 156 Cm. 61 X 63.5 X 61 Inch,13 Net Weight With Standard Accessories 327 Kg Approx., 15 Shipping Dimension With Standard Accessories (L X W X H) Box-1 - 75 X 92 X 120 Cm. 29.5 X 36 X 47 Inch, Box-2 - 119 X 122 X 181 Cm. 47 X 48 X 71 Inch., Box-3 - 32 X 63 X 42 Cm. 12.5 X 25 X 16.5 Inch. To Include Additional Supporting Machine Tools And Materials. Fully Automatic And To Include Software Installation, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Udh - 701 Vekaria Make Or Its Equivalent. , Supply And Installation Of Bangle And Ring Turning Machine Specification: 1.5 To 3 Specification: Bangle Turning Machine (Without Any Accessories)- With Standard Inside Bangle Turning Socket - 1 Pc.- With Standard Outside Bangle Turning Mandrel - 1 Pc.- Bangle Turning Tool Holder - 1 Pc. Bangle Nylon Collets Set- Set Of 33 Inside Turning Collets (Size From 2” To 3”) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Or Its Equivalent. , Supply And Installation Of Bangle And Ring Profiling Machine 2 To 3 No.S 17 To No. 49 With Bangle Stretcher /Pep Tools. Specification: Combined Double Head (Horizontal And Vertical) *Simple To Calculate Divisions Up To 120 Parts*Robust Base With Mounting Holes For Hassle Free Operating*Dual Motor (1 For Each Head) (0.17 Hp/ 2800 Rpm)*Spindles (Rpm) - Horizontal – 5600 / Vertical – 6500* Motor 0.25 Hp* Machine Dimension 76X76x82 Cm, Bangle Nylon Collets With 1 Bangle Holder For Diamond Cut Faceting, Ring Nylon Collets With 1 Ring Holder For Diamond Cut Faceting, Ball Attachment, Half Ball Collets Set Of 6, Chain Attachment And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Model Sku: 16.0701 (Bangle Ring Turning Machine) Or Its Equivalent. , Supply And Installation Of Laser Engraving Machine 12000Mm/Sec, Cooling Systemspecification: Platform - Safety Enclosure, Operating Mode - Mopa Pulse Fiber Laser, Wave Length - 1064 Nm, Pulse Frequency - Upto 2000 Khz, Output Power - 20 Watt Mopa Pulse Fibre Engine, Focusing Optics (Nm) - 100, 163, 254, Cooling Capacity - Fully Air Cooled, Heat Sink, Profile Laser (Optional) - Visible, Red Beam Pilot Laser, Laser Safety Compliance - Fda (Cdrh), Csa, Ce.With High Speed Fiber Laser Marking Technology Marking/Deep Engraving /Cutting On Precious Metals, With Dust / Fumes Collection Unit.Pulse Fiber Laser (Mopa Engines) And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: 3802 Series Laser Marker With Rotary & Laptop Of Laser Star Make From Italy Or Its Equivalent. , Supply And Installation Of Cnc Router Machine With 3D Printer With Supporting Printing Material Specification: Jewelers Engraving 3-4 Axis With Zczb Wax Printer/ Stablizer /Struller/ Chemical /Computer Set /Heater Cleaning Tools/Back Up Ups. Molding Method - Mjp, Molding Size - 294*211*144 Mm, Printing Mode - Xhd:1200*1200*1600 Dpi:16, Dimension Accuracy - + 0.04 Mm/20 Mm, Power Supply - Ac 220-240 V, 50 Hz, 3 Kw, Overall Size - 1415*790*1160 Mm, Overall, Weight - 380 Kg, Package Size - 1700 *1000*1400 Mm, Application Software - 3D Print Data Support Format - .Stl/.Slc, Operation Environment - 18-28 ° C / 30-70 % Humidity And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. , Supply And Installation Of Digital Weighing Machine - Set Of 10 Machines With Calibration Set Up Specification: Weighing Capacity: 62 G, Resolution: 0.1 Mg, Calibration: External, Display Type: Clear Reverse Backlit Lcd Display, Standard Interface: Rs -232 C Repeatability: 0.1 Mg, Weighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: A&D Japan Or Its Equivalent. , Supply And Installation Of Ball Making Machine With Full Set Of Sheet Drawing Of Pipe Making, Soldering, Sheet Striping Machine, Hammering With All Standard Accessories Specification: Power: Single Phase, 220 V, Weight: 158 Kg, Dimensions: 45 X 76 X 106 Cm Suitable For Production Of Small To Large Sized Round, Long Oval, Long Barrel Shaped Balls From Strip Or Tube By Changing Dies, Size: 1.8Mm - 8 Mm, Ac Power 2 Hp Motor, 80-100 Balls Per Minute With Oil Pump, Weight 350Kg, Material Die Steel, Suitable For Production Of Balls Or Other Shapes Chain In Small Dimensions By Changing Dies From 0.60Mm Up To 2.00Mm, Ac Power 1 Hp Motor, 80-100 Links Per Minute With Oil Pump, Weight 300Kg. (Approx), High Grade Die Steel Material. With Separate Sheet Metal Drawing Machine Setup, To Manufacture Hallow And Solid Gold Ball Shapes, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Laser Welding Machine 130 Joule Capacity With 150 Joule Cap.Specification: Source Type - Nd: Yag (Flashlamp), Wavelength - 1064 Nm Output Power (Watts) - 60 W /80 W, Maximum Peak Power - 11 Kw, Pulse Frequency - 0.5 - 50 Hz, Beam Diameter - 0.05 - 2.00 Mm, Burst /Speed Welding - Optimized To Energy Values, Max Pulse Energy - 180 J, Pulse Performance Profile Technology - Exclusive Integrated Software, Soft Touch Resonator Technology - Beam Profile Technology (Optional), Supply Circuit - 120 V Or 230 V (+ 10 %)50/60 Hzfunctionality: 1. Automatic Energy Save Mode, 2. Integrated Preventive Maintenance Alerts, 3. Multi Language System Display, 4. 99 Memory Settings, 5. Preprogrammed Application Parameters Ceramic Cavity New Technology, 6. Inbuilt Cooling System Specially Designed For Jewelry Industry, And 7. Less Maintenance And More Efficient Power Supply Technology., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Workmake/Model: Laser Star Brand Pedistal/Stablizer Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. 10 Mm (3/8 Inch) Letter & Number Punch Set (0 To 9) & 27 Letters, Type Of Product: Punch, Weight: 995 G, Size: 10 Mm, Material: Carbon Steel, Usage: Professional I.E., On Gold And Silverand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries / Kravetto Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. Material Stainless Steel, Model Name/Number Devi: Embossing Dies, Weight 50 Gm Gross Weight 70 Gm, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/ Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes)Pattern Dimensions 3Mm - 50Mm, Material D2 D3, Usage/Application Bangle Ring Jewellery Making As Per Required Designs Quantity - 400 Pieces And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern Type: Round, Pattern Dimensions: As Per Requirements, Usage/Application: Coin Making, Material Stainless Steel, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polished, Hardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Ofgold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern: Type Square, Pattern Dimensions: As Per Requirements, Usage /Application: Coin Making, Material: Bronze And Hard Ss, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polishedhardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply And Installation Of Digital Vacuum Pressure Casting Gold Melting Machine Capacity: 2.4Kg, With Digital Display And Cooling System.Fully Automatic Casting Machine Brand/ Reiacetech Wax Mono Endura / Indigenous Furnace 6 To 8 Flask Capacity/Matrix Investment Mixer 5 Flask/ Steam Machine /Ultra / De-Waxing/Water Jet/Manual Wax Injector/ Tools /Materials For Casting/ Cylinders Powder / Stabilizer Set For All The Machine And Support Materials. Specification:Power: 11 .0 Kw, Frequency: 6 Khz, Ac Line, (50/60 Hz), 3 Phase:400 V + 10%, Melting Temperature (Max): 1300 ° C, Crucible Capacity: 3 Kg Au, Crucible Volume: 208 Cm3, Flask Size (Min): 87 Mm X 127 Mm, Flask Size (Max): 120 Mm X 300 Mm, Vacuum Pump: Included , Weight: 290 Kg (639.3 Lb), Dimensions: 70 Cm X 101 Cm X 135 Cm, Inlet Water Temperature: 35 ° Cfunctionality: Vacuum Casting Machine With Auto/Manual Technology Operating Process With High Pressure Vacuum Motor. Add On Machines For Pre Casting And Post Casting: Reiacetech Wax Injector From Italy Or Its Equivalent. Ingenious Furnace 6 To 8 Flask Capacity With 4 Side Heating Capacity. Indeginous Investment Mixer 5 Flask Capacity. Steam Machine For Gold Tree Cleaning, Manual Wax Injector Ultra Sonaic Machine, Steam De-Waxing Machine, Tool And Consumables For Casting Unit, Stabilizer Set, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Melting Machine With Digital Display And Cooling System Capacity: 2Kg With Digital Display And Cooling System, Two Models With Chiller From 50 Gm To 2 Kg, Melting Capacity / Rio Grande Melting Machine With Digital Display With Graphite Crucible Sets And 50 Gm To 500 Gm Capacity (2 Or 3 Qty Required) Specification: With Ceramic Based Crucible With Digital Thermocouple Heating Sensor Display Screen, Power - 440 V 3 Phase, Water Cooler - 35 Littre (In Built), Weight - 120 Kg, Dimensions - 36 X 30 X 45 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Refinery Machine 2Kg Charged Up To 6 Kg Per Day With Digital Display And Cooling System Should Have Excellent Thermal Insulation To Prevent Loss. Specification: Gold Refining Unit, Power Supply: 400 V / 3 Phase, Power: 0.3 Kw, Dimension In Mm: 1200 X 670 X 1120, Weight: 80 Kgs. To Have Low Running Costs, Fully Automated Process With Process Control And With Fumes Filter & Exhaust Filter And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Koras Refining Unit With Auto Stirrer Set Up With Acrylic Material Or Its Equivalent. , Supply And Installation Of Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed Specification: Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: High Pressure Hydraulic Die Cutting Machine From Hk Brand Or Its Equivalent. , Supply And Installation Of Mesh Chain Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of Box Chain Making Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of V-Chain Making Machine With Standard Accessories Specification: Motor: 0.50 Hp Pmdc Motor & Drive Speed Control Rpm 0 – 1500. 180 Wt. 1 Year All India Warranty. Table: Machine Cabinet Steel Mattel & Weight 49Kg. Electronic Panel: Dc Drive Full Electronic Panel• Sensor (Auto Cut)• Heater (37 Wt., Temperature 800O). Features: Automatic Machine For Venetian Chains, Variable Speed Controller, Forced Lubrications System With Oil Tank And Electronic Brake Sensor, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Best Indian Heavy Duty Machine/ Vekaria Brand Or Its Equivalent. , Supply And Installation Of 12 Pass Wire Drawing Machine With Full Set Of Standard Accessories Specification:Max. Wire Diameter (Guage/Mm) = 20/0.91 To 18/1.22.•Min. Wire Diameter (Guage/Mm) = 36/0.91 To 36/0.19.•Main Motor = 1.5 To 2 Hp.•Cooling Motor = 0.25 Hp.•Machine Weight =225 To 345 Kg. Heavy Duty Sturdy Metal Frame That Holds The Motor.•Transmission Drive.•Speed Control Drive.•Cooling Liquid Tank And Sprayer.•The Unwinding Reel.•The Motorized Winding Reel With Adjustable Clutch.•Steel Palermo For Longer Durability Of Machine. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent. , Supply And Installation Of Sheet And Wire Drawing Machine With Standard Accessories With Heavy Duty Motor Capacity And Auto Stopper Technology Specification: Wire & Sheet Rolling Mill For Gold & Silver • Roller Length 200 Mm X 100 Mm. • Heavy Duty Machine • Bronze Bushings • 5 Hp Electric Motor • Three Phase Power Supply • Hardened Ground Steel • Roller Mouth Openness: 20 Mm. • Weight 800 Kg, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent , Supply And Installation Of Laser Marking Machine Specification: Karat Mark: Laser Marker (20 / 30 W Power) Specification: Laser Power: 20 W-30 W, Laser Wavelength: 1064 Nm, Frequency Range: 20 - 120 Khz 1-600 Khz, Beam Diamter: 7+1 7 + 0.5, Format Supported: All Vector Files And Image Files (Bmp, Jpg, Gif, Tga, Png, Tif, Ai, Dxf, Dst, Plt), Scan Field: 100 X 100 Mm Scan Speed <<7000 Mm/S, Power Regulating Range: 10 -100 %, Cooling Method: Air Cooling, Operating Environment - 0° C - 40 ° C (Non -Condensing), Electricity Demand - 220 V (110 V)/50 Hz (60 Hz), Size & Weight - Around 24 X 17 X 15 In, Gross Weight Around 22 Kgs, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make /Model: Alpha Laser Marker (20/30 W Power) , Supply And Installation Of Xrf Machinemistral Sdd, Item Note: Xrf Karat Meter (Sdd) Stabilizer / Support Specification:Intended Use: Energy Dispersive X-Ray Measuring Instrument (Edxrf) To Determine Thin Coatings, Trace Elements And Alloys. Element Range Aluminium (13) To Uranium U (92) - Up To 24 Elements Simultaneously. Designs Bench Top Unit With Upward Opening Hood, Measurement Direction: From Bottom To Top, X-Ray Source, X-Ray Tube Micro Focus Tube With Tungsten Target And Beryllium Window, High Voltage Three Steps: 10 Kv, 30 Kv, 50 Kv, Aperture (Collimator) 4X Changeable: 00.2 Mm (7,9 Mils), Ø 0.6 Mm (23.6 Mils), Ø1 Mm (39.4 Mils). Primary Filter: 6X Changeable: Ni, Free, Al 1000 ?M (39.4 Mils). Al 500 ?M (19.7 Mils). Al 100 ?M (3.9 Mils), Mylar 100 Um (3.9Mils)Measurement Spot Depending On The Measuring Distance And On The Aperture In Use, The Actual Measurement Spot Size Is Shown In The Video Image. Smallest Measurement Spot Approx. 0.3 Mm (11.8 Mils) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Fisher Xrf Sdd Brand Or Its Equivalent. , Supply And Installation Of Assay Balance: 0.001 Mg Accuracy With Mettler Toledo Scale Je3002 G/M Gold Scale 3.200 With Digital Display. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232 C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Analytical Balance Machine With Digital Display With All Standard Accessories. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Precision Balance Machine With Digital Display With All Standard Accessories. Specification:Weighing Capacity: 62 Gresolution: 0.1 Mgcalibration: Externaldisplay Type: Clear Reverse Backlit Lcd Displaystandard Interface: Rs -232 Crepeatability: 0.1 Mgweighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of 50Gm, 100Gm, 200Gm, E2 Class Wire Weight With Display Attachment Item Note: 50Mg. E-2 Class Wire Weight With Nabl Calibration Certificate. Specification: Calibration Units With Stainless Steel Measuring Exact Weight Standards For Weighing Machines Block. Weights Intended To Ensure Traceability Between National Mass Standards (With Values Derived From The International Prototype Of The Kilogram) And Weights Of Class E2 And Lower. Class E1 Weights Or Weight Sets Shall Be Accompanied By A Calibration Certificate, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Tools And Equipment For Sampling Balling Pliers, Couplers, Scraping Tools, Tongs, Forceps, Rolling Mill Etc. For Complete Assay Set Up Please The Link As Provided Below, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Furnaces, Scrubbers, Parting Tray Etc. Item Note: For Hallmarking Full Setup Center Required. (3 Phase Power, Pollution Clearance Certificate Bis Approval Fee, And All Things) Specification: Annealing Furnace With 220V / Single Phase Along With Supporting Materials. Assay Supplies: Assay Laboratory Spare Parts And Consumables, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work For Complete Assay Set Up Please The Link As Provided Above Against Item No. 29 , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements..I)Cctv Cameras With Night Vision2 Megapixel Ip Cameras With Motorized Verifocal& Pixel Zoom ; Progressive Scan Cmos 1/2.8 Or 1/3Format; Focal Length 2.8 To 12Mm; Zoom Range – 4.2X Varifocal; Multiple Simultaneous Stream; Streams First Stream : Full Hd, 1~30Fps; 1280X720, 1~30 Fps; 704X576, 1-30Fps, Second Stream 704X576, 1~30Fps; 352X288 10~30Fps; Video Compression 32 Kbps ~ 16 Mbps, Support Cbr/Vbr; H.264 Version 3, High Profile Encoding And Motion Jpeg Format Support; 1920(W) X 1080(H) Or Higher Active Pixels; Built-In Ir With 2 Or More Epled; Sw Supported Digital Wdr ; Auto Blc; Sd Memory Slot Upto 32Gb Class 10; Minimum Illumination Icr Colour 0.1 Lux (F1.2 Agc On) B/W 0.001 Lux (F2 Agc On); Shutter Speed 1/25-1/10,000S ; Multiple Resolution 4Cif(704X576), Cif (352X288); 12Vdc / 24Vac / Ieee802.3Af Poe (Rj-45) Support; Supporting All Network Protocols (List The Supporting Protocols); 10/100 Base-T, I/O Audio Support, Audio Compression G.711; Multi-Level User Access With Password Protection; Ip Address Filtering; Https Encrypted Data Transmission; Ieee 802.1X Port-Based Authentication For Network Protection; Ip Address Filtering Https Encrypted Data Transmission; Operating Temperature -10 Deg C To +55Deg C,Onvif Compliant, 36 Months Comprehensive Warranty. Ce, Fcc, Emc & Rohs Certification; And Ul Certification For Core Adaptor Are Mandatory; Onvif Complaint Make: Cp-Plus/Cp-Unc-Tb21zl6s-Vmds27125/Panasonic/Pi-Spw 201Dl/Bosch/ Nti 50022-A3s. Integration Of Cctv System To The Central Server Unified Command Centre Solution Platform (Uccs) At District Police Headquarters Command Center(Dphcc) In Coordination With The Police Department / Designated Agencyand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of 32 Channel Network Video Recorder(Nvr) : Supply, Installation, Testing And Commissioning Of 32Ch Embedded 4K Nvr 4Sata Expandable Up To 40Tb, Audio Input & Output, Two Way Communication Supported, G7.11 Audio Format Support, 320Mb Recording Throughput, 16 Alarm Inputs & 4 Outputs, Rs485, Esata And Rs232 To Be Supported With Maximum 16 Users, Op. Temp -10 To 50 Deg. C, Ndaa Compliant, Ul/Ce/Fcc Certified, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Cp-Plus/Panasonic/Pi-Spw 201Dl/Bosch/ Octavision/Hikvision. , Supply And Installation Of Wallmounting Network Rack Supplyand Fixing Of 6 U Wallmounting Network Rack With Power Spike Including All Accessories Etc., Complete. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make:Hcl / Vall , Supply And Installation Of 8Port Poe Switch Supply & Fixing Of Small Business 8 Port Gigabit Poe Managed Switch, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. Make:Netgear/Dlink , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Lan Cable Cat -6 Utp Cable And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : D Link / Amp / Molex / Legrand / Krone, , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Hard Disk 8 Tb And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : Segate/ Sv-35/Toshiba. , Supply And Installation Of Air Conditioner A/C 2.0 Tonne A/C With Low Power Drive Module.Supply And Transportation Of Inverter Model Cool Type Split Ac Unitwith High Wall Mounted Single Split 100% Copper Indoor And Outdoor Condencing Unit Hermetically Sealed Compressor Suitable For Operation On 230V, 50Hz, 1Phase Ac Supply Capable Of Performing Heat Cool Dehumidifying Air Circulating And Filtering With Cooling And Condensing Units With 3.0 Mts Of Copper Piping, Insulation Kit And 4 Mts Of 4 Core Copper Flexible Chord (Voltage Range 160- 264 Volts) And Cordless Remote Control With Warranty Of Compressor For 5 Years And Comprehensive Maintenance For 2 Years2.0 / 1.8 Tr 5 Star Capable Of Delivering 21600 Btu/Hr And Above With Operating On Refrigerant R-32 / R-410 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Daikin / Toshibha / Carrier / Blue Star / Hitachi Or Equivalent , Supply And Installation Of Computers: Core-I7 10Th Gen Processor, 8Gb Ram, 1Tb Hdd, Windows 10 Pro. Specification: General :Wired Usb Keyboard & Optical Scroll Mouse 1 X Ps/2 Combo Port 2 X Usb 3.2 Gen 1 Ports 6 X Usb2.0 Ports 1 X Rj-45 Port 1 X Hdmi Port 1 X Vga Port 1 X Audio Port (Line Out/Line In/Mic In) 1 X Pci Express X16 Gen 3.0 Slot 1 X Pci Express X1 Gen 2.0 Slot 1 X Audio Port (Line Out/Line In/Mic In) 450W 19V/0.84A 80Mm X 310Mm X 395Mm 510Mm X 360Mm X 182Mm 12.5 Kg (Total Pc) Ce, Rohs Table Top 3 Years Warranty Cpu, Monitor, Keyboard & Mouse, User Manual, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Ups 10 Kva System (8 Kwatt ) Specification:Input Voltage 80 / 400 / 415 Vac; 3 Phase, Ninput Voltage Range ± 15%Input Frequency 50 / 60 Hzinput Frequency Range ± 10%Input Power Factor > 0,85Output Power Factor 0,8Output Voltage 380 / 400 / 415 Vac; 3 Phase, Noutput Frequency 50 Hz / 60 Hz (Selectable)Battery Type No Maintenance Batterybattery Unit 30Charge Voltage 405 Vdcbattery Charge Time 8 Hours To 90% Capacity After Deep Dischargebattery Test Automatic And Manuel Battery Test Systemover Load Capacity 100% ~ 125% Load 10 Minutes; 125% ~ 150% Load 1 Minute; > 150% Load On The Bypassdimension Wxhxd (Mm) 490 X 1200 X 680Weight ~ 240 Kg., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Generator (20Kva Dg Set) Specification: Power: 20 Kva (16Kw) Fuel Consumption (At 100% Load): 5.09 Ltrs/Hr Fuel Tank Capacity: 63 Ltrs Phase: 3 Phase Dry Weight (Kg): 720 Frequency: 50 Hz Engine: 2 Cylinder, In-Line 4 Stroke, Radiator Cooled Engine, Electrical Starter Motor With Soft Start Engagement Feature, Battery Charging Alternator. 1 X 12 V Dc Battery, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
17.
Power #10410528 Price Bid
Tender For Smp-Nilakkal-Development Of Core Area At Nilakkal (Re-Tender)- 1 1Site DevelopmentClearing and Grubbing Road LandClearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.(II) By Mechanical Means(A) In area of non-thorny jungle 2 Excavation in Soil with Dozer with lead upto 100 mExcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. 3 Compacting Original Ground(ii) Compacting original ground supporting subgradeLoosening of the ground upto a level of 300 mm below the subgrade level, watered, graded andcompacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as perTechnical Specification Clause 303.5.2. 4 Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.(ii)Using Gravel mix soil. 5 Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.By Mechanical Means with 1 km lead 6 Turfing with SodsFurnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309. 7 2Retaining Wall and step Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 8 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 9 3Paving the walk way with Grass Pavers, Krishnasila Granite stone, Buffalo grass etc. Providing and fixing of precast concrete interlocking Grass PaversM 30 grade300x300x120mm size of (Brand : Basant Betonswith modelART LINE or similar) having surface drainage of28.6%,manufactured from fully computerized automatic stationery hydraulic vibratepressed machine and fully computerized automatic batching plant.Interlocking paver block to be fixed on the bed compacted into 75mm thick coarse sand zone III or similar approved specification and filling the joints with the sand of approved type and quality or as specified and as directed by Engineer-in-charge. The rate should include the cost of providing a sand bed and filling the joints with fine sand (Fine sand zone IV OR SIMILAR), compacting and proper embedding /laying of interlocking paver blocks into the sand bedding, layer through vibratory compaction by using Plate Compactor, filling the joints with sand and cutting of paver blocks as per design, finishing and removing extra sand etc. complete as per direction of Engineer-in-Charge. 10 Providing and fixing KRISHNASILA black granite 90x60x5 cm Flamed surface on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 11 Providing and fixing 60x30x2 cm Granite stone block ( K WHITE) Flamed surface on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 12 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge 13 Providing and laying curb stone(12.50x22.50x30cm size)(sadarhally) thick stone slab over 50 mm (average) thick base of sand etc. all complete as specified and as directed by the Engineer in- Charge 14 Grassing with buffalo grass including watering and maintanence of the lawn till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, in rows 5cm apart in both directions. (watering & maintanance till the completion of project work and handing over to client) 15 Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 16 4Annadanapura (1 Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 17 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 18 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 19 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 20 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers. 21 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 22 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 23 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 24 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 25 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain) /manual) etc. complete. 26 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 27 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 28 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 29 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 30 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 31 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 32 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 33 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 34 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 35 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 36 5 Resting Pavilion -Type 1 (4 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 37 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 38 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 39 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 40 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 41 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 42 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 43 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 44 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 45 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 46 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 47 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 48 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 49 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 50 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 51 12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand) 52 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 53 6Water kiosk - (2 Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 54 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 55 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 56 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 57 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 58 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 59 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level 60 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 61 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 62 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 63 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 64 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 65 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 66 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 67 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 68 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 69 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 70 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 71 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 72 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 73 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm 74 7Resting Pavilion -Type 2 (2 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 75 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 76 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 77 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 78 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 79 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 80 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 81 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 82 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 83 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 84 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 85 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 86 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 87 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 88 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 89 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 90 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 91 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 92 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 93 8 Resting Pavilion-Type 3 (6 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 94 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 95 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 96 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 97 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 98 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 99 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 100 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 101 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 102 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 103 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 104 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 105 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 106 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 107 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 108 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 109 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 110 9 Resting Pavilion- Type 4 (15 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 111 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 112 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 113 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 114 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 115 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 116 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 117 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 118 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 119 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 120 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 121 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 122 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 123 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 124 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 125 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 126 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 25 mm thick 127 10 Resting Pavilion-Type 5 (2 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 128 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 129 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 130 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 131 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 132 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 133 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 134 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 135 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 136 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 137 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 138 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 139 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 140 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 141 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 142 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 143 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 144 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 145 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 146 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 147 11 Entrance PavilionEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 148 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 149 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 150 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 151 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 152 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 153 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 154 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 155 Exposed Laterite masonry with neatly dressed laterite stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two level including all cost of materials, labor charges etc. 156 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 157 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 158 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 159 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 160 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 161 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 162 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 163 12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand) 164 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 25 mm thick 165 12Information / Aid post (4 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 166 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 167 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 168 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 169 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 170 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 171 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 172 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 173 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 174 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 175 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 176 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 177 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 178 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 179 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 180 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick. 181 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm 182 13Stone Bridge Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 183 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 184 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 185 Stone work plain ashlar in arches in superstructure upto floor V level in cement morter 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with and admixture of pigment matching the stone shade. One face dressed Coursed rubble 186 14 DrainageEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 187 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 188 Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 189 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 190 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 191 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 192 15 Handrailing work Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 193 16Resting Pavilion-Type 6 (1 Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 194 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 195 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 196 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 197 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 198 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 199 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 200 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 201 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 202 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 203 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 204 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 205 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ). 206 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 207 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 208 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 209 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 210 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 211 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 212 17Resting Pavilion-Type 7 (4Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 213 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 214 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 215 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 216 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 217 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 218 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 219 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 220 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 222 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 223 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 224 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 225 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 226 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 227 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 228 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 229 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 230 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 231 18 Resting Pavilion-Type 8 (4Nos)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 232 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 233 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 234 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 235 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 236 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 237 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 238 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 239 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 240 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 241 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 242 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 243 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 244 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 245 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 246 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 247 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 248 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 249 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 250 19 Providing granite pillars and Kalvilakku Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 251 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 252 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete 253 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 254 Supplying and fixing truncated natural stone Kalvilakku with 9 vilakku thattu of 5.5mtr height, 200cm base width, the design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 255 Supplying fixing truncated square natural stone pillar of 4.5mtr height, 60cm base width,60cm top width, 90cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 256 20 Connecting bridge from Core area to Devi templeEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil 257 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Hard rock (blasting prohibited 258 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 259 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) 260 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 261 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level 262 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 263 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. G.I. pipes 264 21 Approach Road Below Connecting bridge from core area to Devi temple Excavation in Soil with Dozer with lead upto 100 mExcavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. 265 Compacting Original Ground(ii) Compacting original ground supporting subgradeLoosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2. 266 Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.(ii)Using Gravel mix soil. 267 22 Administrative block Unit-1 (2Nos) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 268 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 269 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 270 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 271 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 272 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 273 Centering and shuttering including strutting, etc. and removal of form for: Stairs, (excluding landings ) except spiral - staircases) 274 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 275 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 276 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 277 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 278 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete 279 Exposed Laterite masonry with neatly dressed laterite stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two level including all cost of materials, labor charges etc. 280 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading ( using Mechinery( crain)/manual) etc complete. 281 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes 282 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 283 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 284 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 285 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 286 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 287 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 288 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 289 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 290 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 291 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 292 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. 293 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 294 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 295 Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood35 mm thick shutters 296 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Second class teak wood 297 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc. 298 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. G.I. pipes 299 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 300 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 301 23 Administrative Block Unit-2 (1 No)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil 302 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 303 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand) 304 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 305 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers 306 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 307 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 308 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work upto plinth level 309 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 310 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more 311 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 312 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete 313 Exposed Laterite masonry with neatly dressed laterite stone of size 30X20X20cm or nearest size in cement mortar 1:6 for superstructure above plinth level up to floor two level including all cost of materials, labor charges etc. 314 Supplying and fixing truncated square natural stone pillar of 2.5mtr height, 28cm base width,20cm top width, 30cm capital width and intermediate design as shown in the architectural drawing. Cost of conveying, loading & unloading (using Machinery (crain)/manual) etc. complete. 315 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 316 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 317 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 318 Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). 319 Providing & fixing on roof pressed clay ceiling tiles 30x25mm size of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). 320 Providing and fixing good quality Teak wood eve board 20 cm wide 2.5 cm thick including all charges etc. complete. 321 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 322 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 323 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 324 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 325 Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick 326 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. 327 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 328 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 329 Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood35 mm thick shutters 330 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Second class teak wood 331 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc. 332 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. G.I. pipes 333 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 334 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 335 1 Planting of Trees and ShrubsDigging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 336 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 337 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through the sieve of I.S. designation 20 mm 338 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-incharge (excluding cost of earth and manure) 339 Supplying and stacking at site Neem Cake from approved source, including carriage upto 5 km lead complete (Neem cake measured in 50 kg gunny bags will be reduced by 1 kg per bag for payment) 340 Supplying of trees (Ficus microcarpa) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 341 Supplying of trees(Ficus racemosa) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 342 Supplying of trees (Ficus relegiosa) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 343 Supplying of trees(Ficus benghalensis) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 344 Supplying of trees(Cassia Fistula) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 345 Supplying of trees(Mimusops elengi) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 346 Supplying of trees(Saraca asoca) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 347 Supplying of trees(Azadirachta indica) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 348 Supplying of trees(Strobilanthes kunthiana) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 349 Supplying of trees(Ocimum tenuiflorum) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 350 Supplying of trees(Nyctanthes arbor tristis) with multi branches, disease free, healthy in big poly bags of size 30 cm with a girth of 10 cm as per direction of the officer-in-charge. 351 Planting of trees including watering providing required support ,dressing of surface etc complete as per the direction of officer in charge. (excluding cost of plant) 352 Planting of shrubs including watering providing required support ,dressing of surface etc complete as per the direction of officer in charge. (excluding cost of plant) 353 Complete maintenance of trees & Shrubs for 1 Year (Outside garden features), jobs like making of basin at regular interval i/c watering, weed free site & pruning and replacing the dead trees with same specification and height as per direction of officer in charge. Water arrangements to the plantation site need to be done by Contractor. 354 Providing and fixing M. S. tree guard 45 cm square in plan, height 1.20 metre above ground level and 0.40 metre below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x3 mm, 1.6 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical mambers shall be welded to 4 nos. 25x6 mm M. S. flats placed horizontally around the vertical member of the cage. One name plate of 1mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/ PWD/ any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer, completein all respect. 355 2 SignagesEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 356 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 357 Providing and fixing stone slab of Sectional Dimension 600mm x 1500mm ,Thickness 100mm ,cutted to required dimension and shape with fine dressed surface, including the all lead ,lift loading, unloading and transportation etc complete. 358 Providing and fixing signage board made up of 1mm thick, 304 grade stainless steel sheet brushed finish of required dimensions as per the drawing with given information etched on it, and made in given profile as shown in dwg including cost of all Labours and Materials etc complete. 359 1ElectrificationWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 360 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 361 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm 362 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 363 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 364 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 365 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 366 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 367 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 368 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 369 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm 370 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) 371 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp 372 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 373 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.4 core 6 sq mm with factory made clamp 374 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 376 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 377 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 378 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 379 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) 380 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor (8 SWG) 381 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 382 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 383 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) 384 Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. 385 Supply and providing heavy duty A section neoprene gasket in the panel boardA section neoprene beeding suitable for 1.60/ 2.00 mm sheet 386 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) 387 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 388 Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber,suitable size nut & bolt, providng heat shrink sleeves etc. as required. 389 Supply and providing copper earth bus in the panel board 390 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 391 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 392 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps 393 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 394 Supply Conveyance Installation Testing and commissioning of Philips make or equivalent BGP 300 LED 528 757 PSU 35W GI Post Top Lantern fittings having efficiency of 100 and above LM/W, Diffused optic 440V Driver P2P protection high cut off @ 325V +_ 15V auto restart with in built surge protection 7KV with pressure Die cast aluminium housing 4000K with IP 68 protection in position and giving connections etc. as required. 395 Supply Conveyance Installation Testing and commissioning of Wipro make or equivalent Arcus Step Light LT51-750-XXX-30-XX Compact non corrosive Aluminium body with high lumen output of 7W LED 3000K in position and giving Connections etc. as required. 396 Supply Conveyance Installation Testing and commissioning of Philips make or equivalent BGP 150LED 520WW 8W LED Spike Light with Robust diffuser IP design 65/IK06 protection housing with Die cast aluminium with tempered glass for precise light distribution in position and giving connections etc. as required 397 Supply Conveyance Installation Testing and commissioning of Philips make or equivalent BCP151 LED NW PSU 220-240V 7043 17W Bollard light having efficiency of 53 LM/W housing by pressure Die cast Aluminium IP65 protection with mounting wall bracket dimension of 177X395X700mm with surge protection 4KV THD<10% conforming to IEC60598 in position and giving connections etc. as required. 398 Supply Conveyance, installation, testing and commissioning of Philips make or equivalent Tango BVP 483 LED 185CW SWB PSU GR Flood light best in class lens design and optical integration with single die-cast ceramic base high power LED with 10KV SPD is provisional inside luminaire dimmable option 1- 10V integrated flood optics to ensure uniform distribution, maintenance free system ideal for area lighting in position and giving connections etc.as required. 399 Supply Conveyance Installation Testing and commissioning of 4M Decorative Lamp Poles of Crompton Make BRASSO Lamp Poles in position and necessary nut and bolts etc. as required. 400 Supply and Providing Hensel make Junction Box size 93X93X62MM with insulation voltage 690V AC/DC made with Thermo Plastic with IP65 protection in accordance with IEC60670- 22 knock out for cable Entry/Exit as required. 401 Supply and Providing Hensel make Junction Box size 104X104X70MM with insulation voltage 690V AC/DC made with Thermo Plastic with IP65 protection in accordance with IEC60670- 22 knock out for cable Entry/Exit as required. 402 Supply and Providing Hensel make Junction Box size 130X130X77MM with insulation voltage 690V AC/DC made with Thermo Plastic with IP65 protection in accordance with IEC60670- 22 knock out for cable Entry/Exit as required. 403 Supply Fabrication of Feeder Pillar Box of size 1.5M H X1.2M WX0.30M in position as directed by Engineer in charge ( The Fabrication details specified in the Fabrication Item. 404 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. 405 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size 406 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 407 Supply and providing the 25 x3 mm brass bolt and nut with washers on the existing MS box /Container/earth bus etc. as required including drilling necessary holes as required. 408 Supply and providing the 25 x 6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 409 PLUMBING, SANITARY & IRRIGATION 1 SEWAGE & DRAIN SYSTEM INTERNAL AND EXTERNAL Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2 410 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 411 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 412 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 413 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 414 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 415 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall 416 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall 417 Providing , fixing , testing and commissioning pvc multy inlet (110x75x50x50x50) floor trap of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required 418 Providing , fixing , testing and commissioning pvc P trap with multy inlet or single inlet connection of required sizes of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required 419 Providing, fixing, testing and commissioning at site 100x100 mm square C.P.cast brass or stainless steel Grating Cover with protection from cockroaches of matching size of multi inlet or P trap complete in all respects. 420 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 421 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 422 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow 423 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 424 Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling 425 Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Y 426 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap 427 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 428 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow 429 2 CP AND SANITARY FIXTURESProviding and fixing of Floor Mounted European type W.C. pan with seat cover and external Flush tank with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:Make: Hindware/Jaquar/Equivalent 430 Providing and fixing of Wall Mounted European type W.C. pan with seat cover and external flush tank with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: Make : Jaquar/Hindware/Parryware/Equivalent 431 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 432 Supplying,fixing & testing of Concealed Stop Cock with Over Head Shower including all accessories ,cutting and making good the walls wherever required Make : Jaquar/Hindware/Parryware/Equivalent 433 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap 434 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collar and bush approved quality and colour .15 mm nominal bore with 45 cm length 435 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 436 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 437 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighting not less than 190 gms 438 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of430x260x350 mm or 340x410x265 mm sizes respectively. 439 Supplying and Fixing of C.P. Urinal push cock of approved quality. Make : Jaquar/ Hindware/ Parryware/ Equivalent 440 Supplying and Fixing of Urinal Partition of approved quality. Make : Jaquar/ Hind ware/ Parry ware/ Equivalent 441 Supplying and Fixing CP Robe Hook of approved Quality Make : Jaquar/ Hind ware/ Parry ware/ Equivalent 442 Supplying and Fixing CP Soap Dish of approved Quality Make : Jaquar/ Hind ware/ Parry ware/ Equivalent 443 Supplying & fixing of 4 nos of Grab bar and 1 no of Folding type Grab bar with necessary fittings at both side of commode for physically challend persons all complete as directed. Make :Jaquar/Hindware/Parryware/Equivalent 444 3INTERNAL WATER SUPPLYProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 445 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 446 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost ofcutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes 447 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm nominal outer dia pipes 448 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm nominal outer dia pipes 449 Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreVertical 450 Providing and fixing Y Strainer of approved quality of following sizes. Make: Zoloto / SKS/ Leader/ Equivalent 100mm dia 451 Providing and fixing CI Butterfly valve of approved quality as per IS 13095 of following sizes. Make: Zoloto/SKS/Cim/Equivalent 65mm dia 452 Providing and fixing CI Butterfly valve of approved quality as per IS 13095 of following sizes. Make: Zoloto/SKS/Cim/Equivalent 100mm dia 453 4 IRRIGATION-PVC PIPING WORKS Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2 454 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 455 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 456 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 457 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 458 Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2 459 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 10 Kgf/ cm2 460 5DRIP AND ACCESSORIESSupply, Fixing & Commissioning of flexible,kink resistant 16mm Blank tubing and resistance to UV damage and algae growth brown in colour and wall thickness 1.2mm, pressure rating 0.58 to 4.1Bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 461 Supply, Fixing & Commissioning of Xeri bug emitter pressure compensating with self flushing emitter, and selfpiercing barbs,flow rates 1 GPH UV resistant colour coded with working pressure 1.0 to 3.5bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 462 Supply,Fixing & commissioning of 3 Large Capacity Disc Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar), Maximum Temperature Up to 140ºF (60ºC). 463 Supply,Fixing & commissioning of 21/2 Large Capacity Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 464 Supply,Fixing & commissioning of 63mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 465 Supply, Fixing & commissioning of 40mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 466 Supply, Fixing & commissioning of 32mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 467 Supply,Fixing & commissioning of 25mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 468 Supply,Fixing & commissioning of 20mm Y Type Disc / Screen Filters for submain filteration Have High Flow & Low Maintenance With a Solid Build,Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 469 Supply,Fixing & commissioning of self-closing flushing valves that are installed at the end of the irrigation line for effecting flushing of the line at the beginning of every irrigation cycle, thus avoiding the clogging of the emitters /sprinklers through removal of particles, sediments and other impurities from the water. 470 Supply, Fixing & commissioning of 9 - Gauge Galvanized Steal Rod Comes Sharp tips provide easy connection into all soil types, Staple Distribution Tubing , XF Drip Line or XBS Tubing to Finished Grade. Notched Sides. Corrosion -Resistant of TIE DOWN STAKE etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 471 Supply, Fixing & commissioning of Gromatetake off Connects XF Series Drip Line and Blank Tubing to PVC Mainlines at Low Pressures. 16mm GTO 472 Supply,Fixing & commissioning of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm Tee . etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 473 Supply,Fixing & commissioning of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm COUPLING. etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 474 Supply,Fixing & commissioning of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm ELBOW. etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 475 Supply,Fixing & commissioning of 17mm End cap S Type for dripline closure at the end of the dripline etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 476 6 SPRINKLERS AND ACCESSORIES Supply, Fixing & commissioning of Pop up spray head Spray bodies, with Rotary nozzle having mutilple stream MPR spray having Co-moulded wiper seal is molded into the cap and features an encased plastic cage to provide unmatched resistence to grit, nozzle having capable of covering 5.2-7.2m at 1.4 - 3.8 Bars pressure, True flushing mechanism,Thick streams and large water content & Low precipitation rate and the enviroment. Additionally, the pressure-activated, multi-function seal design assures a positive seal without excessflow-bywhich enables more heads to be installed on the same valve, Two-piece ratchet mechanism, Features is Precision controlled flush at pop-down clears debris from unit, Construction of time-proven UV_resitant plastic. Pop spray body shall with stand upto 4.8 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures.etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 477 Supply, Fixing & commissioning of 1/2 Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. Flex pipe textured for wet conditions.The fittings shall be made of UV resistant thermo plastic etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge..SA Series. 478 Supply, Fixing & commissioning of PVC service saddle of varying size upto 63mm dia with pressure rating of PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 479 7VALVES AND ACCESSORIESSupply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 75mm with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 480 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 63mm with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 481 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 40mm. with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 482 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 32mm. with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 483 Supply,Fixing & commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 25mm. with pressure rating PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 484 Supply,Fixing & commissioning of a double acting air and vaccum release 1/2 Air release valve . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Only for Drip Irrigation etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 485 Supply,Fixing & commissioning of 18 Jumbo Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & Having Dimensions @ Top Opening 10 Dia & Bottom Opening 12 13/16 Dia etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 486 Supply,Fixing & commissioning of 12 Rectangular Standard Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:18 1/4 L X 13 W & bottom opening :21 1/4 L X 15 15/16W X 12 H etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. PVB/VB 487 Supply,Fixing & commissioning of 3/4th Quick coupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 3RC 488 Supply,Fixing & commissioning of 3/4th Key threads into top of QCV to provide water access etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. 489 Supply,Fixing & commissioning of 3/4th Hose Swivel Made up of Solid Brass Swivels up to 360 degrees to allows hose to be pulled in any direction & Also to prevent Hose Damage etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. SH-0 490 8PUMPING ACCESSORIES Supply,Fixing & commissioning of Pressure release valve 2 with pressure setting from 0 to 7 Bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge 491 9AUTOMATION EQUIPMENTSupply,Fixing & Commissioning of Direct burial14 Awg x 2 Maxi cable with PVC insulated UL stndard 493 with impregnated polyethene jacket and soft annealed tin coated copper confirming to ASTM B-33 for two way communication between decoder controller and decoders complete. 492 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 493 Supplying ,fixing & commissioningdirect bury -on wire Connector with strain relief UL486D Certified with water proof silicon sealent,fits wire from 22ga to 66ga asper specification complete DBRY 494 Supply,Fixing & Commissoning of ASTM Station Modular Controller UV resistant,wall mount case,with LCD display ,non volatile memory for 100years,10KV surge protectionwith removable front panel and programmable under battery in office,total run time calculator ,short detect errors,one touch watering,wityh contract default programe s,slow closing valve removable battery with sensor terminals Work has to be executed as per the approved drawings and/or as per the directions of the engineer-incharge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. 495 Supply,Fixing & commissioning of 63mm Solenoid globe angle inlet Valves with fabric reinforced Nitrile diaphram Material and rugged PVC durable glass -filled nylon construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10.4 KSC and maximum flow of 150GPM ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance30ohm with provision to attach PRS-Dial PGA Pressure Regulation Optional PRS-D 496 Supply,Fixing & commissioning of Automatic rain shut off Device,latching hinge with multiple rain fall setting 5mm to 20mm UL CUL listed and CE approved RSD BEX
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
19.
Drinking Water Supply and Sanitation #10398718 Price Bid
Supply, Installation And Demonstration Of New Instruments Required For Different Water Testing Laboratories Situated Across The State Related To Water Quality Monitoring And Surveillance Activities Under Public Health Engineering Department, Gov. , Supply, Delivery, Installationof Uv-Visible Dual Beam, Programmable, Scanning & Suitable For Water Quality Analysis Spectrophotometer Having 1.8 Nm Band Width,Wavelength Range:190 To 1100 Nm, Accuracy: ±1.0 Nm; Measuring Methods: Absorbance, % Transmittance, Concentration; Detector: Dual Silicon Photodiodes; Connectivity: Usb Type. Light Source: Xenon Lcell Holders: 3 Cell Holder-One Adjustable Holder For 13 Mm To 25 Mm Round Vials, One Holder For Up To 50 Mm Rectangular Vials And One Holder For 10 Mm Square Vials & One 6 Cell Holderfor Multi-Sample Measurements In 10 Mm Square Vials. , Supply, Delivery & Demonstration Of Vertical Autoclave, Double Walled, Radial Locking Arrangement, Working Chamber Ss, Lid & Ring-Ss, Outer Wall Covered With Ss Sheet, Complete With Automatic Pressure Cut Off Facility, Steam Release Valve, Low Water Level Cut-Off Device, Pressure Gauge, Safety Valve. Size: 20 X 12.Relitech/Obromax/Nsw , Supply, Delivery, Installation Of Microprocessor Based Analytical Balance, 210 Gm Capacity, 0.1 Mg Redability, With Internal Calibration Facility, Air-Shield, Ss Pan, Spirit Level Indicator & As Per Direction Of Eic..Shimadzu/Sartorius/Mettler/Equiv , Supply, Delivery, & Demonstration Of Hot Air Oven Working Chamber Size (Medium Size) : 16Xi6Xi6_Ss Working Chamber, Temperature Controlled By Thermostat &: Indicated By In- Built L-Shapcd Thermometer. The Supplies To Be As Per Specification In Notice & Direction Of Eic Relitech/Obromax/Nsw , Supply, Delivery & Installation Of Sample Storage Refrigerated Chamber, 200 Lit Capacity, 1 To 10 Deg C Range, 3 Shelves Suitable For Sample Storage, Static Type Refrigeration. Glass Viewing Door For Sample Inspection, Forced Air Circulation System To Maintain Uniform Temperature Throughout The Chamber. Data Recorder Indicates The Temperature Of The Working Chamber Of The System With Printable Data Download Facilities Should Be Available. , Supply, Delivery, Installation Ofbasic Ion Meter Ph Ion 7320/ Stara 214/Ab250 Ph/Ion Meter Withfluoride Ion Selective Electrode Ionplus Combination/F800 For Fluoride Ion Meter & As Per Specification In Notice & Direction Of E.I.C. Thermo-Orion-Fisher/Wtw. The Scope Of Supply Includes Training Of Calibration & Measurement Of Fluorie Analysis In Drinking Waterby The Supplied Ion Meter. , Supply, Delivery & Demonstration Of Incubator,Working Chamber Size (Medium Size) : 16X16X18. Ss Working Chamber,Double Walled Unit With Outer Body Made Of Ms Sheet,Rust Proof Duly Powder Coated And Inner Chamber Made Of Stainless Steel (304 Grade) Sheet. Provided With Adjustable Stainless Steel Perforated Shelves. The Double Walled Door Shall Be Fitted With Glass Window To Facilitate Viewing Inside Chamber Without Disturbing The Inner Temperature And Shall Have Synthetic Rubber/ Fiber Gasket. Temperature Control By Micro Processor Based (Pid) Digital Temperature Indicator-Cum-Controller (With Display For Set Value And Present Value) For Temperature Control From +5º C Ambient To 70ºc, ± 0.5ºc At 50ºc. Fitted With Air Circulating Fan. To Be Fitted With Beaded Heating Elements Placed In Ribs, At Bottom And Sides For Uniform Heat Distribution.To Work On 220/230 Volts Ac Supply. The Supplies To Be As Per Specification In Notice & Direction Of E.I.C. , Supply, Installation & Demonstration Of Basic Salinity -Conductivity-Tds Meter Cond 7110/Stara-212 With Cell Tetracon 325-Duraprobe 4 Electrode Conductivity Cell & As Per Specification In Notice & Direction Of E.I.C. Thermo-Orion/Wtw/Equivalent , Magnetic Stirrer, With A Fractional Horse Power Motor Mounted In A Sheet Metal Housing, Fitted With Speed Regulator, Max. Speed 1200 Rpm. Top Plate Shall Be Of Stainless Steel, Cap 1 To 2 Litre, Supplied With Ptfe Coated Stirring Bar. The Supplies To Be As Per Specification In Notice & Direction Of E.I.C. , Supply, Lnstallation. Demonstration Of Software Controlled Vp100 Continuous Flow Vapour Generation System (For The Analysis Of As With Detection Limit 5Microgm/Lit,Se, Sb, Te, Bi And Sn In Trace Level) & Should Be Set With Existing System Of Ice 3300. The Vp100 Continuous Flow Vapour System Shall Perform Hydride And Mercury Vapour Measurements With Significant Sensitivity Improvement. An Air/Acetylene Flame Or An Electrically Heated Cell Shall Beused For Atomization. The Vp100 Unit Shall Incorporate The Reagent Reservoirs, A Variable Speed 4 Channel Peristaltic Pumps, Control Electronics And Gas Liquid Separator. An Integrated Mass Flow Controller Shall Be Fitted Which Will Allow The Carrier Gas Flow To Be Controlled And Monitored Through The System Software And The Continuous Flow Principle Eliminates The Need To Clean The Reaction Vessel After Each Sample. The Vp100 Operates Automatically Under Data Station Control.Solution Transport: Variable Speed, 4 Channel Peristaltic Pump Using Continuous Flow Principle. The System Shall Befully Automatic And Controlled By The Data Station And Control Software Should Be That Of Flame System. Suitable For 220/240V And 110/120V Operation. The Material Shall Be Supplied With: 2 T-Cells (Open Ended, Silica, 120 Mm Long), Pump Tubing, Reagent Bottles, Glass Bead , Supply, Installation, Commissioning Of Ultrapure Water Generation System, Electrically Opearted (240V) For Type-I Water: Ultrapure Water Generator-Suitable For Icp-Oes /Aas Spectrometer, Desktop Module, Constructed With Pigment-Free Materials, Conical Bottom Outlet Allows For Complete Draining And Efficient Cleaning And Disinfection. Inorganics (Resistivity @ 25°C): Up To 18.2 M?-Cm. Organics (Toc): 1-3 Ppb . Bacteria: , < 1Cfu/Ml . Flow Rate: 1.0 Lit/Min. The System Should Be Complete With Feed-Water Purification Unit Which Should Produce Water Of Type-Iii Feed Water & Suitable For Ultra Pure Water Generator System.The Suitable Feed Water Unit System,Feed Water Reservoir Etc. To Be Provided With Ultrapure Water Generation System And Shall Be As Per Satisfaction Of Engineer-In-Charge. Elga/Xylem-Evaqua/Thermo/Millipore , Purulia
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
20.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
21.
Educational and Research Institute #10363836 Price Bid
Tender For Pem Electrolyzer Unit; A The PEM Electrolyzer Unit must contain: PEM Electrolyzer Unit (as shown in figure) PEM electrolyzer unit with end plates as Galvanized steel, platinum and iridium catalyst, flow plates with serpentine flow path, silicon sealing, Teflon insulator, GDL membrane with catalyst, 5 stackable cells can be stacked in 1,2,3,4 or 5 numbers based on output flow requirement with following specifications for each cell: MEA Size - 25cm2 Cell Voltage - 1.9-2.5 V Cell Current - 30 A End Plate Size - 85*75*8 Hydrogen Production - 140 ml/min Max. Pressure - 5 bars Water intake Flow rate - 0.12 ml/min Operating Temperature - 40 to 60 deg. C Water Requirement – Purified Water with conductivity <1μS/cm (Recommended) Water Manifold – for cell stacking along with MICA heater and a temperature controller Water Tank: 10L Polypropylene Tank for storing distilled water with water heater Water Distiller: Water Distiller with purified water output: 1L/hr along with a handheld water conductivity meter Water Pump: Rotary Peristaltic pump Water Pressure – 1 bar Max. Flow Rate – 50ml/hr Variable DC Power Supply for Electrolyzer: Voltage Range: 0-10 V Max. Current: 50 Amp. Gas Water separator: Gas Water Separator for Hydrogen; 5bar Gas Water Separator for Oxygen; 5bar Gas Drying Unit: Desiccant based three stages drying for Hydrogen Desiccant based three stages drying for Hydrogen Gas Collection Unit: Gas collection unit consist of: Pressure Guage with Pressure Controller for Hydrogen; 0-5 bar Pressure Guage with Pressure Controller for Oxygen; 0-5 bar Non-Returning Valve for Hydrogen;0-5 bar Non-Returning Valve for Oxygen;0-5 bar Mass flow Controller with PC communication for Hydrogen; 0-8LPH Mass flow Controller with PC communication for Oxygen; 0-8LPH Three Way Manifold for Hydrogen with double stage pressure gauge Three Way Manifold for Oxygen with double stage pressure gauge Hydrogen Cylinder; Type 1 – 10L water capacity Oxygen Cylinder; Type 1 – 10L water capacity Safety Unit: Safety Unit consists of 2 Hydrogen Leak detectors with alarm placed over manifold and cylinder with solenoid valves placed after electrolyzer. Relays for automatic Shutdown operation Safety Actions: Auto Shutdown of equipment, Loud Alarm, and gas shutoff at critical points. Warranty Period: The product/system is covered under warranty for a period of 36 months from the date of successful installation and commissioning.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Madhya Pradesh View Result →
22.
Health and Family Welfare #10350409 Price Bid
Tender For supply of Digital Pet Ct Scanner As Per The Specification Except The Following , Advanced Dedicated Work Station For Pet-Ct With Oncology, Cardiology & Neurology Packages , Dual Head Injector , Dry Laser Imager , Full System Ups , Lead Glass , Additional Workstation With 1 Tb Storage Capacity , Dose Calibrator For Pet , Portable Survey Meter For Pet , Contamination Monitor For Pet , Personal Pocket Dosimeter , Tungsten Vial Shield For Carrying Isotopes , Syringe Shields For 2 & 5 Ml , Shielded Waste Decay Drum For Pet Radionuclide , L Bench With Lead Glass For Pet , Lead Lined Storage Cabinet , Interlocking Lead Bricks Including Corner Blocks , Shield Lead Carrier For Pet Doses , Light Weight Vinyl Lead Apron Of 0.5Mm Lead Equivalent , Foot Operayive Waste Bin For Pet , Dose Calibrator Shileding Ring For Pet , Dose Dispensing Unit , Decontamination Kit , Tongs 12, 18 And 24 Inch , Transport Container (Biodex Or Equivalent) , Cushioned Sofa Seats , Icu Trolley , Water Purifier (Hot And Cold) , Televisions 42 , Office Table , Dining Table With 10 Chair , Rubco Chairs , Modular Book Shelf With Glass Doors , Library Chair , Library Table , Jefferson Chair , Projector And Screen , Sound System With Fixed Mic And Wireless Mic , Pharma Refrigerator 400L , Induction Cooker , Non Revolving Chair , Refrigerator 260L , Emergency Trolley , External Lasers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 2.31Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 50.5.33.1Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M- 20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note: Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Up To Plinth Level , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.2Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , Providing And Fixing Gi Chicken Wire Mesh 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes Including Cement Slurry And Pegs/Nails With Nailing Machine As Required Before Plastering Etc. Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 13.12- 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand )And A Top Layer 6 Mm Thick Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand) Finished Rough With Sponge. , 22.5Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.81Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand/Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P/S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , 18.7.2 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes , 18.7.3Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes , 18.8.2Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes , 18.8.3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 25 Mm Nominal Outer Dia Pipes , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Switches & Sockets: Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20/25 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 20/25 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Ceiling, Wall And Exhaust Fans: Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With 16/0.20Mm Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep -5Star Rated Bldc Ceiling Fan Complete With 300Mm Down Rod , Canopies, Shackles And Blades Working On 230V/240V Single Phase A/C , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Db Mcb Switch Gear: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required 100 Amp, 30 Ka 4 Pole , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Cable Supply Laying And Termination: Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc.As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 300 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Earthing & La: Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads 40Mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.00 Mm Copper Conductor ( 14 Swg) , Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube,Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Fixing Of Lightning Conductor Finial (Single Prong) With Base Plate Including Holes Etc. Complete As Required , Jointing Copper / G.I. Tape (With Another Copper/ G I Tape, Base Of The Finial Or Any Other Metallic Object) By Riveting / Nut Bolting/ Sweating And Soldering Etc As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. , Providing And Laying G.L. Tape 32 Mm X 6 Mm From Earth. Electrode Directly In Ground As Required , Laying Copper/ G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Led Fixtures S&F: Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Supplying And Fixing Of Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Supplying And Fixing Ofrecess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Supply Of 18W Led Downlighter With A Nominal System Lumen Output Of Minimu 500 Lumens. System Wattage Should Not Exceed 18W. The Luminaire Shall Have A Rated System Lifetime Of 50,000 Burning Hours. The Luminaire Should Have A Color Temperature Of 5700K And Cri>80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.95. Housing Shall Be Crca Powder Coated With Pmma Diffuser.Driver Shall Have 85% Efficiency. Similar To Wipro Make Ld06-221-Xxx-57-Xxor Eqivalent , Supply Of 12W Led Downlight, High Efficiency With A Nominal System Lumen Output Of 760 Lumens. Luminaire Wattage Should Not Exceed 12W. The Luminaire Should Have Acri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Slim Led Batten In Aluminium Housing And Decorative End Caps. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Mirror Led Light Fixture Of 4000 K,Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. Simialr To Model Number Ld07- 131-060-40-Wh Of Wipro Make Or Equivalent. , Fire Alarm, Fire Extinguisher & Safety: Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Supplying, Installing, Testing And Commissioning Ofconventionalsingle Action Manual Call Point , Supplying, Installing, Testing And Commissioning Of Conventional Hooter With Builtin Flasher Lightwith Base Ul/En Listed. , Supplying, Installing, Testing And Commissioning Of 2 Core X 1.5 Sqmm Fr Pvc,Multistrand Copper Cu Ar Cable Confirming To Is Standards And Specifications. Make: Polycab / Century , Providing Installating, Connecting, Testing And Commissioning Heat Detectors Type With Mounting Base, Blinking Ledas Required Complete And Integration , Supplying, Installation, Testing And Commissioning Ofconventional Photoelectric Smoke Detectorsas Required To Connect With Existing System , Providing And Fixing Of Response Indicator As Required , Conventional Single -Zone Fire Panel With Batteries, Battery Charger Mimic Diagram Etc , Supply And Providing2/3 Mm Thick Sythetic Type And 1 M Wide Electrical Grade Chequered Type Rubber Mat To Withstand 3.3 Kv Dielectric Strength Conforming To Is 5429/1969. , Supply And Providing Laminated First Aid Chart Duly Framed And Placed In A Conspicuous Location For Clear Vision. , Numbering & Lettering: Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Hvac Works: Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230V Ac , Ssb And Ups Panel:Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Statutory Approvals: Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , Elv: Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 32Mm , Supplying And Laying Of Following Pair Armoured Telephone Cable Through Wall/Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge/Consultant And Making Good All Damages Made For Installation. 5 Pair , Kronebox-Supply,Erection,Testingandcommissioningoffollowingpairkronewithbox Including Mounting Frame, Enclosure Of Isi Grade With Lockable Front Cover With All Accessories Required For For Complete Installation In Wall As Directed By The Engineer In Charge. 10Pair , Supply, Installation, Testing And Commissioning Of Basic User Phone With Necessary Connection As Required For Complete Installation As Directed By The Engineer In Charge. , Supplying And Drawing Of 6 Core Sm Armoured Optical Fibre Cable (Ofc) Through Wall / Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge / Consultant And Making Good All Damages Made For Installation. , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Drawn Of Utp 4 Pair Cat 6A Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6A Rj 45 Computer Jack Modular Socket Outlet , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 9U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Dismantling Works : Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Cctv & Public Addressing System: Supply, Installation, Testing And Commissioning Of Ip Based 3.6 Mm Fixed Lens, 2Mp Resolution, H.264 / H.265, 1/2.8 Progressive Scan Cmos Day/Night, Ir Dome Poe Enabled Camera,20 To 30 Meters Ir Range, 120 Db Digital Wdr With All Connectors And Necessary Accessories For Mounting In False Ceiling As Required For Complete Installation As Directed By Engineer In Charge. , Ceiling Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Ceiling Mount Metal Grille Speakers With Inbuilt Line Matching Transformer With Power 6W With All Accessories Required For Complete Instllation As Required. , Wall Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Wall Mounted Speakers With Inbuilt Line Matching Transformer With Power 9Wwith A Volume Controller To Adjust The Volume Individually As Per The Requirement With All Accessories Including Wall Mounting Kit Required For Complete Instllation. The Volume Controller Shall Be Fixed Separately As Per The Site Condition For Individual Control. Cost Inclusive Of Necessary Interconnection Including Conduit, Connection Wire Etc , Mechanical Ventillation System: Axial Fans: Supply, Installation, Testing And Commissioning Direct Driven Axial Flow Fans Suitable Formountingonwallorductinstandardgalvanized/Powdercoatedsteelconstructionwith Requiredrating,Static,Singlemotorandflexibleconnectiontoconnectwithducting/Plenum, Louvers With Birdscreen. The Cost Inclusive Of Ducts Required As Per The Layout. 50 - 250 Cfm , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
23.
Heavy Industries and Public Enterprises #10233116 Price Bid
Design, manufacturing, supply, installation & Commissioning of Skid Mounted Single Tube Reactor test set-up , Gas Connection Line Of Co2 Complete With Ball Valve, Filter, Inline Pressure Regulating Valve With Inlet Outlet Pressure Gauge, Pressure Safety Valve, Mass Flow Controller And Non-Return Valve. , Gas Connection Line Of H2 Complete With Ball Valve, Filter, Inline Pressure Regulating Valve With Inlet Outlet Pressure Gauge, Pressure Safety Valve, Mass Flow Controller And Non-Return Valve. , Gas Connection Line Of Co Complete With Ball Valve, Filter, Inline Pressure Regulating Valve With Inlet Outlet Pressure Gauge, Pressure Safety Valve, Mass Flow Controller And Non-Return Valve. , Gas Connection Line Of N2 Complete With Ball Valve, Filter, Inline Pressure Regulating Valve With Inlet Outlet Pressure Gauge, Pressure Safety Valve, Mass Flow Controller And Non-Return Valve. , Gas Manifold For Connecting 4 Co2 Cylinders Along With Necessary Isolation Valves. Pt With Low Pressure Alarm , Gas Manifold For Connecting 8 H2 Cylinders Along With Necessary Isolation Valves. Pt With Low Pressure Alarm , Gas Manifold For Connecting 4 Co Cylinders Along With Necessary Isolation Valves. Pt With Low Pressure Alarm , Gas Manifold For Connecting 4 N2 Cylinders Along With Necessary Isolation Valves. Pt With Low Pressure Alarm , Feed Tank-01 43A-Tt-01 Complete With Manual Feeding Option, Pressure Gauge, Level Transmitter, Temperature Element, Provisions Of N2 Blanketing And Necessary Accessories Viz. Isolation Valve, Pressure Safety Valve, Tubing/Hose, Drain Nozzle With Double Valve Systemetc. , Dosing Pumps 43A-Pa-01 Complete With Inlet/Outlet Isolation Valves For Transfer Of Liquid Feed, Tubing/Hoses, Strainers Etc. , Static Mixture (43A-Sm-01) , Auto Sample Handling And Switchover System With Necessary Accessories As Mentioned In Annexure T1 To T3 , Manual Sampling Handling System With Necessary Accessories As Mentioned In Annexure T1 To T3 , Feed Heater 43A-Fh-01: As Mentioned In Annexure T1 To T3 , Reactor 1 43A-Re-01: As Mentioned In Annexure T1 To T3 , Reactor 2 43A-Re-02: As Mentioned In Annexure T1 To T3 , Thermosyphon Loop: As Mentioned In Annexure T1 To T3 , Product Cooler 43A-Ee-01: As Mentioned In Annexure T1 To T3 , Water Chiller 43A-Wc-01: As Mentioned In Annexure T1 To T3 , Gas-Liquid Separator 43A-Vv-01: As Mentioned In Annexure T1 To T3 , Product Storage Tank-02 43A-Tt-02: As Mentioned In Annexure T1 To T3 , Skid For Single Tube Reactor Unit , All Tubing, Fittings, Valves, Tubing Work: As Mentioned In Annexure T1 To T3 , All Miscellaneous E&I Items: As Mentioned In Annexure T1 To T3 , Power And Control Panel, With Plc & Required Hardware, Software, Cables, Field Equipment And Overall Electrical Work As Mentioned In Annexure T1 To T3 , Installation, Testing And Commissioning Work: As Mentioned In Annexure T1 To T3 , Spares As Mentioned In Section K , Gas Detectors As Mentioned In Annexure – T1 To T3. , Line Heaters As Mentioned In Annexure – T1 To T3
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 3
Maharashtra View Result →
24.
Agriculture #10131578 Price Bid
Supply Of Veterinary Instruments / Equipments / Chemicals / Reagents / Media For The Year 2021-22-2 100 Ml Pp Bottle With Rubber Bung & Aluminium Cap- Sterilized, Round / Rectangular Shape, Rubber Bung And Aluminium Cap To Fit The Bottle 3 300 Ml Pp Bottle With Rubber Bunk & Aluminium Cap Sterilized, Roundshape, Rubber Bung And Aluminium Cap To Fit The Bottle 4 Adsons Tissue Forceps Stainless Steel, Size-6 5 Ai Gun Auto Ss Lock Mini Compatible With 0.25 Ml French Mini Straw With Container Made Up Ofpvc 6 Ai Gun With Container Container Made Up Ofpvc / Pp To Pack Ai Gun, About 19” Ai Gun For Goat Length - 10 Inch Device Used For Depositing Of Semen Via 0.25 Ml Straw, Make - 304 Stainless Steel Easy To Use Lock And Unlock Sheath To Accommodate French Mini Straw 0.25Ml, Diameter - 0.15 Cm Diameter Match With Artificial Insemination. 7 Ai Gun For Goat Length - 10 Inch Device Used For Depositing Of Semen Via 0.25 Ml Straw, Make - 304 Stainless Steel Easy To Use Lock And Unlock Sheath To Accommodate French Mini Straw 0.25Ml, Diameter - 0.15 Cm Diameter Match With Artificial Insemination. 8 Ai Sheath Container Made From Pvc, Size- 19 Inch Length Inner Día Is 46 Mm 9 Ai Sheath For Goat Sterile, Individually Wrapped Outer Plastic Shells Which Fit Over The Gun Providing A Secure Seat For The Straw. Packs Of 50 Pieces. 10 Ai Straw Cutter Stainless Steel Made From Pvc, Non-Corrosive Plastic With A Stainless Steel Blade Which Cuts Off The Proper Length With A Push Of The Button 11 Allis Tissue Forceps 6, Ss 12 Artery Forceps 6 Curved Ss 13 Artery Forceps 6 Straight, Ss 14 Av Cone A Latex Director Cone With Rolled Ends For Use In An Artificial Vagina For Bulls. Approx. 270 Mm. 10-1 / 2 In. L X 2-1 / 2 In. Dia. At Opening, 5 / 8 In. Dia. At Tip, 9 Inch Long 15 Av Hose 10 Inches Long, 2.5” Dia Approx Fitted With Good Quality Brass Valve For Pouring Hot Water. The Brass Valve Should Be Leak Proof For Air And Water. The Rubber Body Should Be Slightly Pliable. Both The Edges Should Be Rounded, Smooth And Elevated To Hold The Rubber Liner. 16 Av Liner Made From Natural Latex Material, Washable And Reusable, Ample Length To Fit Over Ends Of Vagina And Also Provide Rubber Bands, 12 Inch Long 17 Babcock Tissue Forceps, Ss, 6 ( Each ) 18 Biohazard Bag, Hdpe, , 12X24 With Thickness 50Μm 19 Bio-Medical Waste Bin Plastic Waste Bin With Foot Pedal, Colour-Blue, White, Red, Yellow, 20Ltr Capacity 20 Bone Curette, 8, Ss 21 Bp Blade No.10-Ss, Sterile Individually Packed, For Handle No. 3 22 Bp Blade No.24-Ss, Sterile Individually Packed, For Handle No. 4 23 Bp Blade No.12-Ss, Sterile Individually Packed, For Handle No. 3 24 Bp Blade No.23-Ss, Sterile Individually Packed, For Handle No. 4 25 Bp Handle No.4 ( Approxm. 130 Mm ) Stainless Steel 26 Bp Handle No.3 Approxm.125 Mm. ) Stainless Steel 27 Breeder Thermometer Material - Glass, Accuracy - 0.1 Degree Celsius 28 Casting Rope Cotton 1 / 2 X 15 Yards 29 Casting Rope Cotton 1 X 15 Yards 30 Catgut No-1-0 , Chromic Catgut, Suture Length-76Cm 31 Catgut No-2-0 , Chromic Catgut, Suture Length-76Cm 32 Cell / Tissue Homogenizer • Ideal Homogenizer For Extraction From Samples Like Bacterial / Yeast Cells, Plant Tissues, Animal Tissues And Other Tough Samples • Accommodates Wide Range Of Screw Cap Homogenizing Tubes Sizing 3X2ml • Powerful Motor – Homogenizes The Most Challenging Samples • Designed To Generate Lesser Heat And Convenient Loading Capacity – 3X2ml Speed Range – 2800 To 4000 Rpm Run Time – 3 Second To 180 Second Pulse Mode On / Off Timer - 3 Second To 99 Second Operating Condition - 40C To 450C Weight – 2.8 Kgs Dimensions ( Lxwxh ) – 235 X 158 X 140 Mm 33 Chizzle Forceps 10, Ss 34 Cotton Apron , Brown For Vet Asst., Size- Xxl ( Each ) 35 Cotton Apron, Sky Blue For Vets, Size-Xl 36 Cotton Apron, Sky Blue For Vets, Size-Xxl 37 Cotton Apron, Sky Blue For Vets, Size- L 38 Cryo Box Polycarbonate, Autoclavable To Old 81 Cryo Vials Of 1.8 Ml And 4.5Ml Numbers Moulded Into Grid System In The Box Corresponds To Number Printed In The Lid. 39 Cryo Container 1.5Lt. Capacity 1.5 Liter Of Liquid Nitrogen .This Metal Container Is Meant For Doorstep Ai By Private Ai Practitioners And Should Be Sturdy 40 Cryo Container 100Lt. / Jumbo 12 Metal Liquid Nitrogen Storage Container 41 Cryo Container 35Lt. High-Strength Aluminium Alloy Liquid Nitrogen Container, Neck Diameter: About 50Mm, Loss Mass:0.29Liter / Day, Static Holding Time:123 Days 42 Cryo Container 3Lt. Capacity 3-4 Liters Of Liquid Nitrogen With Static Evaporation Loss Rate Of 0.135 Liters Per Day At Stp, Six Canisters With Od 38Mm, Height 120Mm. The Level Of Liquid Nitrogen From Bottom Should Be About 20Cms. The Neck Diameter Should Be 50Mm. This Container Is Meant For Doorstep Ai By Private Ai Practitioners And Should Be Sturdy. 43 Cryo Container 50Lt. Liquid Nitrogen Container 50 Liter, Neck Diameter:50Mm External:Diameter 500Mm, High 790Mm, Loss Mass:0.37Liter / Day Static Holding Time:134 Days 44 Cryo Gloves For Liquid Nitrogen Handling, Can With Stand Up To-170.C Temperature, Length - Upto 45 Cm 45 Cryo Gloves For Liquid Nitrogen Handling, Can With Stand Up To -170.C Temperature, Length-Upto 45Cm 46 Cryovessel With Wide Mouth For Storage Of Frozen Semen Straw 550 Ltrs With 80-100 Canisters For Storage Of Frozen Semen Straw 47 Crystoscope Set Of Light With Glass Slides For Observing Fern Pattern 48 Digital Ph Meter Ph Range -0-14, Resolution : 0.001 Ph, Temperature Range : 0.0 To 100ºc ( Manual Compensation ) Display : 31 / 2 Digit Led Display Power Supply : 230Vac ±10%, 50 Hz Calibration Check Facility & Calibration Error Indication For 7.00 & 4.00 Ph 49 Dip Stick For Measuring Liquid Nitrogen Made From Styrene, About 4 Ft In Length With Graduations In Inches For Measuring Liquid Nitrogen Manually 50 Disposable 3 Ply Face Mask Disposable 3 Ply Face Mask, Melt-Blown Cloth & Non-Woven Material, Blue With Adjustable Nose Strip ( Pe Wire, Metal Free ) , Flat / Round Elastic Ear Loop, Hypoallergenic / Non-Irritating Fibre Glass Free Fabric, Inner Layer Made Up Of White Soft Facial Tissue, Bacteria Filtration Efficiency ≥95%, Low Breathing Resistance-Delta P < 29, 4 Pa 51 Disposable Head Cap Surgeon’S Head Cap, Cotton, Green Colour 52 Douch Can E.I. Can With 2 Meter Long Rubber / Polythene Tube ( 1.5Cm Diam. ) With Blunt Ends And Controlled Nozzle 53 Dressing Forceps 6, Ss ( 2 Nos ) 54 Egg Incubator Electrically Operated, 500 No. Eggs Capacity For Incubation Of Eggs For Vaccine Production Without Brooder. Power-Dc 12V;Ac110 / 220V, Humidity Range-0~99%Rh 55 Empty French Mini Straw Pvc Straw Of Different Colours.Pack Of 2000 Straws ( 0.25Ml ) 56 Eye Hook ( Large ) Ss With Blunt Ends 57 Eye Hook ( Small ) Ss With Blunt Ends 58 First Aid Box General 59 Flexible Sivl Cryocan Filling Hose Stainless Steel Braided Transfer Hose, Material Grade- Ss316, 4-5Mts. Long 60 Forceps Specimen Holder Ss10 Length 61 Frozen Semen Straw Lifter Stainless Steel, L-Shaped. Designed To Lift Semen Straws With Vertical Serrations Made At Tip ( 10” ) 62 Full Hand Disposable Gloves Polythene Make, 36 Inch 63 Gel Pack / Ice Pack 1 Pkt ( 100Gm ) 64 Gel Pack / Ice Pack 1 Pkt ( 450 Gm ) 65 Glass Slides, Microscopic-Optically Clear, Distortion Free Surface 66 Gloves Latex- Disposable, ( Large And Medium Size ) 67 Gloves Nitrile- Disposable ( Large / Medium ) 68 Goblet ( 35Mm ) Pvc, Plastic Goblets 35 Mm Diameter, 118Mm Long For French Mini Straws, Should Be Made From Virgin Plastic Compound, Should Withstand Repeated Cooling To -196 Degree Centigrade And Thawing To Ambient Temperature. The Goblets Should Be Compatible With The Imported Make Straw Counting And Filling Machine 69 Goblet ( 65Mm ) Pvc, Plastic Goblets 65 Mm Diameter, 118Mm Long For French Mini Straws, Should Be Made From Virgin Plastic Compound, Should Withstand Repeated Cooling To -196 Degree Centrigrade And Thawing To Ambient Temperature. The Goblets Should Be Compatible With The Imported Make Straw Counting And Filling Machine. 70 Gum Boots Full Size ( In Pair ) Sizes-8, Should Be Of Lightweight, Made Of Rubber / Synthetic Rubber With Cloth Lining Inner Side. Height – 14” 71 Gum Boots Full Size ( In Pair ) Sizes-9, Should Be Of Lightweight, Made Of Rubber / Synthetic Rubber With Cloth Lining Inner Side. Height – 14” 72 Gum Boots Full Size ) ( In Pair ) Sizes-10, Should Be Of Lightweight, Made Of Rubber / Synthetic Rubber With Cloth Lining Inner Side. Height – 14” 73 Gynaecology Aprons Size: M And L, Full Length Made Of Synthetic Material And Provided With Braided Cotton Ends For Tying With Pockets. 74 Haemocytometer ( Neubauers ) Thick Crystal Slide With The Size Of Glass Slide ( 30 X70 Mm And 4 Mm Thickness ) Double Improved Neubauer Counting Chamber, Leucocyte Pipette ( White Bulb ) , Erythrocyte Pipette ( Red Bulb ) , 16 Cm Transparent Silicone Tubing ( Colour Coded For Each Pipette ) , 0.4 Mm Glass Coverslip 75 Haemoglobinometer ( Sahlis ) Consist Of Comparator Box Which Has Brown Colored Glass On Either Side, Hb Pipette Which Is Marked Upto 20Mm3 ( 0.02Ml Blood ) , Tube With Markings Of Hb On One Side , Glass Rod , Dropper 76 Head Light Neutral Light Led, Compact And Lightweight, 90 Degree Adjustable Light Beam, Powered By A Single Aa Alkaline Battery, Hm23 Light Outputs 77 Hoof Cutter Made Of Carbon Steel Alloy And Has A Sharp Cut And Is Durable, 78 Hot Air Oven 0°C To 250°C Temperature, Uniform Air Circulation Across Chamber, Digital Temperature Controller Cum Indicator, Excellent Uniformity At High Temperature, Stainless Steel Inner Chamber, Corrosion Resistant Exterior, Fume Ventilation Points On Both Sides, Steel Wire Mesh Cable Trays, Over Temperature Protection, Toughened Glass Window, Power Supply- 220 Volts / 50 Hz, Single Phase 79 Hot Water Bath Stainless Steel Double Walled With 304 Grade. Temperature Should Be Controlled By Micro Processor Based On Digital Temp. Controller. Auto Water Low Level Water Cut Off. Temp. Range: 5 Deg. C Above Ambient To 95 Deg. C.Temperature Measurement / Control Accuracy Not Higher Than + / - 1°C. 80 I / V Saline Set Saline Set Meant For Intra Vinous Infusion Of Fluids 81 Insemination Gloves- Full Arm Length 82 Mastitis Detector Digital / Electronic With 4 Cups With Reading For 4 Quarter 83 Mastitis Kit Mastitis 4 Cup Padel, With Solution 500Ml ( 2 Kit Unit ) 84 Mayo Scissors , Ss, Straight, 6 85 Mayo Scissors Ss, Curved, 6 86 Mayo Scissors Ss, Straight, 8 87 Mayo Scissors Ss, Curved, 8 88 Metal Detector For Bovines The Machine Will Visually And Acoustically Indicate If There Is Any Type Of Metallic Foreign Body Inside The Stomach 89 Mosquito Artery Forceps 4Curved, Ss 90 Mosquito Artery Forceps 4Straight, Ss 91 Mouth Gag Large Ruminants, Ss 92 Mouth Gag Small Ruminants, For Dog, Ss 93 N-95 Mask 5 Layers With Nose Clips And Elastic Strip, Filters Out At Least 95% Of Very Small ( 0.3-Micron ) Particles When Properly Fitted And Donned, Minimal Leakage Occurs Around Edges Of The Respirator When User Inhales, 94 Needle Holder Ss, 6 95 Non Invasive Multiplexed Biomass Sensor System Automated, Continuous, Real Time Multi-Vessel Biomass / Od Monitoring With Working Volume Done To 10Ml, Biomass Sensitive Range-<0.01 To >600 Od Units, 12Mm Diameters, 96 Nylon Suture Coarse Fiber, In Hank Of 100 Threads ( Pkt ) 97 Olsen-Hegar Needle Holder, 6 With Cutting Edge 98 Peristaltic Pump-201V Notor-Stepper With Motor Torque-10Kg, Rpm-1 To 200, Tube Size- 1 To 8Mm, Flow Rate-0.8 To 1800Ml / Min, Discharge Pressure-2 Bar, Maximum Discharge Height-10Liters, Dimension- ( L-325Xw-170Xh-250 ) Mm 99 Peristaltic Pump-401V Notor-Stepper With Motor Torque-1 / 6Th Hp, Rpm-20 To 240, Tube Size- 8 To 19Mm, Flow Rate-250 To 20000Ml / Min, Discharge Pressure-3 Bar, Maximum Discharge Height-30Liters, Dimension- ( L-500Xw-250Xh-400 ) Mm 100 Petridsih Borosillicate Glass, 100Mm, 150Mm 101 Ph Meter, Bench Top Digital Ph Meter With Led / Lcddisplay, Range 0-14 Ph With 0.01 Resolution, Auto / Manual Calibration, Temperature Range 00-100°C Electrically Operated With Electrode And Electrode Holder. 102 Polydiaxonone Suture No.1-0 ( Pack Of 12 ) 103 Polydiaxonone Suture No.2-0 ( Pack Of 12 ) 104 Polyglactin Suture No-1-0 ( Pack Of 12 ) 105 Polyglactin Suture No-2-0 ( Pack Of 12 ) 106 Ppe Kit A ) Dangri- Disposable, Free Size Full Sleeve, Polypropylene Material 90 Gsm B ) House Gloves: Disposable, Isi Mark, 10 Nos C ) Shoe Cover: Disposable With Thick Padded Foot Base D ) Face Mask With Hepa Filter E ) Disposable Protective Glasses 107 Probang Metal 108 Rat Toothed Forceps 6, Ss 109 Rat Toothed Forceps, 8, Ss 110 Safety Goggles / Protective Eye Wear Moulded Of Soft Flexible Polyvinyl Chloride Covering Eyes , Nose And Have Vents To Reduce Fogging . The Front Lenses Is Made In Clear Acetate And Can Be Worn Over Regular Eye Glasses 111 Scalp Vein Set Sterile Butterfly Wing Luer Lock, 20G Pouch Pack / Blister Pack Set 112 Scalp Vein Set Sterile Butterfly Wing Luer Lock , 22G Pouch Pack / Blister Pack Set 113 Scissor Blunt 8, Ss 114 Scissors Straight Ss, 10 115 Single Pack Ai Sheath Single Pack , Sterilized To Fit 0.25 Ml Straw 116 Slide Warmer Temperature Range Ambient Temp. To 70° C I.E. Below The Melting Point Of Wax. The Temperature Is Thermostatically Controlled. The Body Is Made Out Of Thick Mild Steel Duly Finished In White Stoving Enamel / Powder Coated Paint With Mat Finished Color Combinations And Top Is Made Of Highly Polished Stainless Steel Sheet. To Work On 220V Ac 50 Hz Single Phase. Length X Width: A ) 30 X 25 Cm B ) 40 X 25 Cm 117 Spirit Lamp Spirit Lamp With Cap Made From Stainless Steel Supplied With Wick 118 Sponge Holding Forceps 10, Ss 119 Ss 316 Storage Tank, Capacity-200Liters, With Accessories •M.O.C Of All Contact Parts : Ss 316 •M.O.C Of All Non‐Contact Parts : Ss 304 Type Of Tank : Torispherical Dish End Vertical Tank •Dia: 700Ø / Shell Ht.: 550 Mm •Shell / Dish Thickness: 4 Mm Steam Heating Jacketed Tank Dia.800Mm X 4Mm Thk. •Shell Thickness: 4 Mm ‐ Ss 304 •Tank With Heat Insulation Jacket With Rockwool Insulation ‐ Dia. 900 Mm •Shell Thickness : 2 Mm ‐ Ss 304 •Tank Internal Surface Mirror Polished. Accessories •Temperature Sensor - 1 No. •Steam Inlet Valve3 / 4 - 1 No. •Steam Trap Assembly3 / 4 - 1 No. •Steam Safety Valve With Pr. Gauge 1 No. •Control Panel- 1 No. •Ss 316 Diaphragm Valve, Size:1 -2 Nos •Vent Filter With Electrical Heating, 10 Long 0.2 Micron P7 Pp Cartridge-1 No. •Sight Glass Assembly3- 2 Nos •1 Tc Compound Pr. Gauge With 4 Dial, ‐1 To 10 Bar Pressure- 1 No. 120 Ss Tray Stainless Steel, 18 X 12 121 Sterilizing Drum / Dressing Bin Made Of Stainless Steel ( Grade: Ss 304 Or Ss-Ln ) , Sets Of Perforation On Drum Body, Slotted Belt With Clamp For Loosening Or Tightening Of Belt To Open Or Close The Perforations On The Body, The Clip When Clamped Will Keep The Belt In Fair Tension, Sizes- Dia × Height ( Inch ) - 9 X 9, Thickness: Heavy Gauge ( 0.6 To 0.7Mm ) , Shape-Round, Finish : Polished 122 Storage Rack For Cold Cabinet Detachable With Adjustable Heights, 6 Ft Length X 2 Ft Wide X 8 Ft Height, Light Class, 2 Mm Thickness, 304 L Grade Ss 123 Straw Cutter Made From Pvc, Non-Corrosive Plastic With A Stainless Steel Blade Which Cuts Off The Proper Length With A Push Of The Button, Easy To Disassemble And Wash Without Tools. 124 Surgical Tray With Cover Stainless Steel, Size- 12 X 10 125 Suturing Needle Size 7, Taper Point, 3 / 8 Circle, 50Mm Long, Ss 126 Suturing Needle Round Shaft, Straight, Taper Point With No Cutting Edge, Ss, 4 Long 127 Suturing Needle Size 10, Cutting Edge, 1 / 2 Circle, 55Mm Long, Ss 128 Suturing Needle Triangular Point With Cutting Edge On The Inner Curvature And Precision-Honed For Added Sharpness’S, 4 Long 129 Table Top Incubator ( Incubator Mini ) Temperature Range 5⁰ C To 60⁰ C With Powerful Fan To Circulate Air For Maintaining Uniform Temperature Inside Chamber, Double-Walled With Puff Insulation. The Inner Chamber Should Be Made By Non-Corrosive, Non-Magnetic Stainless Steel. The Outer Door Should Be Of Powder Coated Crca Steel, Double Door ( Plexi Glass Inner Door To Observe The Sample And Outer Door Powder Coated Crca Steel ) , The Compressor Should Have Cfc Free Refrigerant With Time Delay Switch-On, Digital Led Display Of Temperature. Safety Thermostat To Prevent Overheating With Audio-Visual Alarm Warning Of Temperature Variation, High Temperature Safety Cut Off & Alarms For High / Low Set Parameters, Electrical Requirement: 220-240 V With High Voltage Safety Cut-Off. 130 Tamponing Forceps Made Of Stainless Steel, Length-18 Inch The Tip Should Have Grooves To Grip. 131 Teat Surgery Instruments Teat Surgery Set Containing All Following Items In Dust Proof Cover With Zipper :- Furstenberg’S Teat Siphonwith Round Head And Side Openings , 9 Cms Length Nickel Platedof Diameter 2Mm Along Withstillet. 2 Pc. .2.5Mm Dia2pc. 3.0 Mm Dia1pc. 2.Hug’S Teat Tumor Extractorstainless Steel12.5 Cms Length X 4Mm Dia2pc. 3.Teat Dilator With Screw Action 17 Cms1pc 4.Teat Slitterwith Screw And 2 Blades Danish Pattern 19Cms Length , 3Mm Dia Nickel Plated1 Pc 5. Teat Slitter Swiss Model9.5Cms Length , 4 Mm Dia 1 Pc 6.Lichty Teat Knife With Sharp Point Made Of Stainless Steelto Cut The Extra Growth In Teat Canal. Total Length With Handle18 Cm. Made Of Stainless Steel Material 132 Teat Syphon Stainless Steel, Self-Retreating , Adjustable, 2Mm Outer Diam. 133 Tenaculum 6 Ss 134 Thaw Monitor Should Be Made Up Of Liquid Crystal Temperature Indicating ( 32 0C- 400C ) Device With Triple Laminated And Water Resistant 135 Thermometer, Digital Digital Display, Waterproof, With Alarm And Memory. 32ºc-43ºc In A Strong Plastic Case 136 Thermometer, Oval Oval- Mercurythermometer, Transparent, Range-35ºc-42ºc With 0.1ºc Increment 137 Towel Clip, Ss, 8Cm 138 Trocar Cannula Stainless Steel, 6 Inch Trocar With A Sharp Triangular Point And Handle, Inside The Hollow Tube ( Cannula Or Sleeve ) To Fit The Trocar, For Large Animals, 139 Trocar Cannula Stainless Steel, 4 Inch Trocar With A Sharp Triangular Point And Handle, Inside The Hollow Tube ( Cannula Or Sleeve ) To Fit The Trocar, For Smallanimals, 140 Tweezer Ss, Straight With Serrated Tips, 8 141 Vaccutainer With Needle & Needle Holder 10 Ml Capacity With Edta And Without Edta 142 Vaginal Speculum For Goat Ai Measurement: Length Of The Blades - 16 Cm, Maximum Opening - 8Cm, Working Diameter -4 Cm. Technical Specifications : Material - Stainless Steel, Rust Prevention Procedure -Passivation, Ultrasonic Cleaned - Yes, Lubricate - Yes, Usage - Both Hand, Test Performed - Boil Test, Performance Test, Shape Test, Packing - Individually Packed. 143 Wire Saw Ss, 1.5 M Length With 2 Handles 144 Chemicals Reagents Media 145 Alum ( Potassium Aluminium Sulphate ) Lr 146 10X Tae Buffer Molecular Grade 147 6 X Gel Loading Buffer Molecular Grade 148 Agarose Molecular Grade 149 Anthrax Rapid Test Kit 150 Avian Influenza Antibody Multi Valent Test Poultry Kit Detection Elisa Kit 151 Avian Influenza Virus Antigen Test ( Poultry ) Rapid Test Kit 152 Blood Genomic Dna Purification Kit 153 Blood Genomic Rna Purification Kit 154 Bq Rapid Test Kit 155 Cedar Wood Oil ( R.I. 0 To 1.5 ) Lr 156 D-256 Liq ( Microgen ) Lr 157 Dextrose Ar 158 Dna Ladder 100Bp 100Bp Dna Ladder 159 Dnase &Rnase Free Molecular Grade Water Molecular Grade 160 Dpx Mountant Lr 161 Early Pregnancy Detection Kit Enzyme Linked Immune Assay For Detection Of Early Preganancy-Associated Glycoproteins In Serum Or Plasma / Can Be Used From 28 Days Post Breeding 162 Edta Ar 163 Elisa Kit For Diagnosis Of, Goat Pox, , Rd, Ibd ( Antigen Detection ) Kit 164 Falcon Tube With Graduation 50 Ml Tube 165 Formalin / Formal Dehyde ( 37-41% W / V ) Ar 166 Glycerol-98%W / V Ar 167 Goat Pox Virus Antigen Rapid Test Kit Kit 168 Hand Sanitizer Lr 169 High Clean Liquid Soap Lr 170 High Clean Liquid Soap Lr 171 Hi-Sybr Master 2X Molecular Grade 172 Hs Rapid Test Kit Kit 173 Ibd Virus Antigen Detection Rapid Kit Kit 174 Iddex Biochemical Kit For Serum-Glucose Estimation Kit 175 Iddexbiochemical Kit For Serum-Albumin Estimation Kit 176 Iddexbiochemical Kit For Serum-Albumin Estimation Kit 177 Iddex Biochemical Kit For Serum-Calcium Estimation Kit 178 Iddexbiochemical Kit For Serum-Calcium Estimation Kit 179 Iddexbiochemical Kit For Serum-Cholesterol Estimation Kit 180 Iddexbiochemical Kit For Serum-Cholesterol Estimation Kit 181 Iddexbiochemical Kit For Serum-Creatinine Estimation Kit 182 Iddexbiochemical Kit For Serum-Creatinine Estimation Kit 183 Iddexbiochemical Kit For Serum-Magnesium Estimation Kit 184 Iddexbiochemical Kit For Serum-Magnesium Estimation Kit 185 Iddexbiochemical Kit For Serum-Urea Estimation Kit 186 Iddexbiochemical Kit For Serum-Urea Estimation Kit 187 Lubricant For Vaginal Speculum Non-Spermicidal, Sterile Lubricant Used For The Lubrication Of The Vaginal Speculum Prior To Its Insertion ( 50Gmpack ) 188 Lysol 500 Ml 189 Mb Grade Water Molecular Grade 190 Methanol / Methyl Alcohol ( Acetone Free ) Lr 191 N / 10 Hcl Lr 192 Phenyl Mercuric Nitrate ( Pmn ) Lr 193 Phosphate Buffer Saline ( Ph 7.2 ) Ar 194 Potassium Iodide Lr 195 Ppr Virus Antigen Detection Rapid Test Kit Kit 196 Probe Based Animal Theileria Detection Pcr Kit Kit 197 Qiaamp Viral Rna Minikit Cat No 52904 Kit 198 Rd Virus Antigen Detection Rapid Kit- Kit 199 Rectified Spirit Lr 200 Rnase Jap Kit 201 Rotheras Mixture Lr 202 Sabrauods Dextrose Agar Bacteriological Grade 203 Sabrauods Dextrose Broth Bacteriological Grade 204 Silvicide / Peroxide Silver Ar 205 Sodium Chloride Ar 206 Sodium Hydroxide ( Pellets ) Ar 207 Sodium Nitropruside ( Dehydrated ) Lr 208 Standard Nutrientbroth For Hsv Subculture Bacteriological Grade 209 Steri Sweep Molecular Grade 210 Sterile Swab 100 Per Pkt 211 Sulphric Acid ( Conc ) Lr 212 Super Script™ Iii Platinum™ One-Step Qrt-Pcr Kit Catalog Number:11732020 Molecular Grade 213 Taq Pcr Master Mix Molecular Grade 214 Teepol Molecular Grade 215 Thioglycollate Broth With Liver Extract ( Bqv Subculture ) Bacteriological Grade 216 Tissue Genomic Dna Purification Kit Molecular Grade 217 Tissue Genomic Rna Purification Kit Molecular Grade 218 Tris Buffer Ar 219 Trypsin ( Bovine ) Ar 220 Trypsin ( Porcine ) Ar 221 Urine Test Stripsfor Idexx Vetlab Ua Analyzer 1Pk 222 Wide Mouth Sterile Sample Collection Bottle 30-50 Ml Capacity 223 Xylene Ar 224 Amc ( Only The Cost Of Amc To Be Mentioned ) 225 Cell / Tissue Homogenizer • Ideal Homogenizer For Extraction From Samples Like Bacterial / Yeast Cells, Plant Tissues, Animal Tissues And Other Tough Samples • Accommodates Wide Range Of Screw Cap Homogenizing Tubes Sizing 3X2ml • Powerful Motor – Homogenizes The Most Challenging Samples • Designed To Generate Lesser Heat And Convenient Loading Capacity – 3X2ml Speed Range – 2800 To 4000 Rpm Run Time – 3 Second To 180 Second Pulse Mode On / Off Timer - 3 Second To 99 Second Operating Condition - 40C To 450C Weight – 2.8 Kgs Dimensions ( Lxwxh ) – 235 X 158 X 140 Mm 226 Cryovessel With Wide Mouth For Storage Of Frozen Semen Straw 550 Ltrs With 80-100 Canisters For Storage Of Frozen Semen Straw 227 Non Invasive Multiplexed Biomass Sensor System Automated, Continuous, Real Time Multi-Vessel Biomass / Od Monitoring With Working Volume Done To 10Ml, Biomass Sensitive Range-<0.01 To >600 Od Units, 12Mm Diameters, 228 Peristaltic Pump-201V Notor-Stepper With Motor Torque-10Kg, Rpm-1 To 200, Tube Size- 1 To 8Mm, Flow Rate-0.8 To 1800Ml / Min, Discharge Pressure-2 Bar, Maximum Discharge Height-10Liters, Dimension- ( L-325Xw-170Xh-250 ) Mm 229 Peristaltic Pump-401V Notor-Stepper With Motor Torque-1 / 6Th Hp, Rpm-20 To 240, Tube Size- 8 To 19Mm, Flow Rate-250 To 20000Ml / Min, Discharge Pressure-3 Bar, Maximum Discharge Height-30Liters, Dimension- ( L-500Xw-250Xh-400 ) Mm 230 Ss 316 Storage Tank, Capacity-200Liters, With Accessories •M.O.C Of All Contact Parts : Ss 316 •M.O.C Of All Non‐Contact Parts : Ss 304 Type Of Tank : Torispherical Dish End Vertical Tank •Dia: 700Ø / Shell Ht.: 550 Mm •Shell / Dish Thickness: 4 Mm Steam Heating Jacketed Tank Dia.800Mm X 4Mm Thk. •Shell Thickness: 4 Mm ‐ Ss 304 •Tank With Heat Insulation Jacket With Rockwool Insulation ‐ Dia. 900 Mm •Shell Thickness : 2 Mm ‐ Ss 304 •Tank Internal Surface Mirror Polished. Accessories •Temperature Sensor - 1 No. •Steam Inlet Valve3 / 4 - 1 No. •Steam Trap Assembly3 / 4 - 1 No. •Steam Safety Valve With Pr. Gauge 1 No. •Control Panel- 1 No. •Ss 316 Diaphragm Valve, Size:1 -2 Nos •Vent Filter With Electrical Heating, 10 Long 0.2 Micron P7 Pp Cartridge-1 No. •Sight Glass Assembly3- 2 Nos •1 Tc Compound Pr. Gauge With 4 Dial, ‐1 To 10 Bar Pressure- 1 No.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 11
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttarakhand View Result →
27.
Environment and Forests #10074658 Price Bid
Supply , Installation And Commissioning Of Various Scientific Instruments / Equipments In Cpcb- 1 Digital Burette 2 Portable Combustion / Flue Gas Analyzer For O2, Co And With Data Recorder 3 Portable Toc / Hc Analyzer 4 Cod Analyzer ( Closed Reflux ) 5 Laboratory Glassware Washer & Dryer 6 Ion Chromatograph 7 Rotatory Evaporator With Vacuum Pump & Chiller 8 Water Purification System 9 Gas Chromatograph –High Resolution Mass Spectrometer ( Gc-Hrms ) 10 Gas Chromatograph -Ecd Fpo 11 Ultra High Perfomance Liquid Chromatograph ( Uhpld ) With Dad / Pda 12 Portable Ndir / Nduv And Chemiluminscence Analyzer With Sampling Probe Conditioning System 13 Gc-Ms-Atd 14 Ph Meter ( Bench Top ) Display Upto 3 Decimal Place 15 Multi Channel Aerosol Speciation Sampler 16 Low Flow Pump 17 Aerosol Monitor For Indoor Air Quality Measurement 18 Indoor Air Quality Measuring Instrument 19 Mass Flow Controllers With Control Unit ( 08 ) 20 Co / Hc Analyzer 21 Smoke Meter 22 Dispensers Of Different Range 23 Puf Sampler 24 Spe Unit With Accessories 25 Recirculating Chillers 26 Icp-Ms 27 Gc-Ms-Ecd 28 Digital Microscope Dslr Mounted 29 Tclp Extraction System 30 Handheld Geiger Counter 31 Gas Chromatograph ( Fid-Ecd ) 32 Atomic Absorption Spectrophotometer ( Aas ) - Gta / Vga 33 Compact Weather Station ( Portable Meteorology Station ) 34 Prefilled And Preconditioned Thermal Desorption Tubes For Voc 35 Sampling Assembly For Carbonyls Consisting Of Following Pump :- Pump Battery Charger, Twin Port Sampler, Cartridge Adaptor, Male Fitting, Female Fitting, Male Coupler, Female Coupler, Clips, Male Luer Plugs, Female Luer Plugs And Flow Calibrator ( 1-6000 Ml Per Minute ) With Charger 36 Portable Flow Meter 37 Mercury Analyzer 38 Toc Analyzer 39 Turbidity Meter 40 High Volume Sampler 41 Digital Thermo-Hygrometer 42 Platinum Crucible, 3 Ml 43 Cod Digestion System ( 30 Sample Position ) 44 Moisture Analyzer 45 Heating Assembly For Soxhlet Extraction 46 Vaccum Filtration Assembly 47 Laminar Flow System 48 Isokinetic Stack Sampling Assembly With Heated Prob ( Stack Monitoring Kit Suitable For Epa Method 5, 17, 23A, 29 Etc ) 49 Handheld Gps Receiver 50 Digital Barometer
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 35
Contract Date: Ref. Documents Contract Value : 6.21 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : 10.85 Lakh
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
30.
Water Resources and Irrigation #9943546 Technical Bid
Tender For Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge. All Kinds Of Soil , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Electric Resistance Or Induction Butt Welded Tubes , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate , 12 Mm Cement Plaster :1:4 (1 Cement : 4 Coarse Sand)With A Floating Coat Of Neat Cement Punning. , Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing And Fixing At Or Near Ground Level Precast Cement Concrete In Kerbs, Edgings Etc. As Per Approved Pattern And Setting In Position With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including The Cost Of Required Centering, Shuttering Complete. 1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Supplying Of Earth In Rough Excavation, Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks For Filling Up Ground Depresssion Lead Upto 15 Km And Lift Upto 1.50 M. , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:4 (1 Cement : 4 Coarse Sand , Providing And Laying Cement Concrete In Retaining Walls, Return Walls,Walls (Any Thickness) Including Attached Pilasters, Columns, Piers,Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets,Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering,Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Washed Stone Grit Plaster On Exterior Walls Height Upto 10Metre Above Ground Level,In Two Layers,Under Layer12Mm Cement Plaster 1:4 (1 Cement : 4 Coarse Sand ), Furrowing The Under Layer With Scratching Tool,Applying Cement Slurry On The Under Layer @ 2 Kg Of Cement Per Square Metre, Toplayer 15Mm Cement Plaster 1: 1/2:2 (1Cement: 1/2 Coarse Sand : 2 Stone Chipping 10Mm Nominal Size), Inpanels With Groove All Around As Per Approved Pattern,Including Scrubbing And Washing The To Player With Brushes And Water To Expose The Stone Chippings,Complete As Per Specification And Direction Of Engineer-In- Charge (Payment For Providing Grooves Shall Be Made Separately). , Extra For Washed Grit Plaster On Exterior Walls Of Height More Than 10 M From Ground Level For Every Additional Height Of 3 M Or Part Thereof. , Forming Groove Of Uniform Size In The Top Layer Of Washed Stone Grit Plaster As Per Approved Pattern Using Wooden Battens, Nailed To The Under Layer, Including Removal Of Wooden Battens, Repair To The Edges Of Panels And Finishing The Groove Complete As Per Specifications And Direction Of The Engineer-In-Charge :20 Mm Wide And 15 Mm Deep Groove , Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M), Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Of Wall With Existing Angle Iron Y Shaped Placed 2.4 M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape(R.B.T.) / Spring Core (2.5Mm Thick) Wire Of High Tensile Strength Of 165 Kg/ Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/ Metre (Cost Of M.S. Angle, Cement Concrete Blocks Shall Be Paid Separately) , Constructing Brick Masonry Road Gully Chamber 50X45X60 Cm With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including 500X450 Mm Pre-Cast Reinforced Cement Concrete Horizontal Grating With Frame Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Plain Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana/Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is:9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering And Finishing As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Minimum Specified Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level : Concrete Of M10 Grade With Minimum Cement Content Of 220 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Fixing In Position Pre-Cast Reinforced Cement Concrete Manhole Cover And Frame Of Required Shape And Approved Quality Ehd - 35 Circular Shape 560 Mm Internal Dia , Providing And Laying Neelgiri/Mexican Grass Turf With Earth 50Mm To 60Mm Thickness Of Existing Ground Prepared With Proper Level And Ramming With Tools Wooden (Dhurmos) And Than Rolling The Surface With Light Roller Make The Surface Smoothen And Light Waterning With Sprinkler And Maintenance For 30 Days Or More Till The Grass Establish Properly, As Per Direction Of Officer-In-Charge. , Digging Holes In Ordinary Soil And Refilling The Same With The Excavated Earth Mixed With Manure Or Sludge In The Ratio Of 2:1 By Volume (2 Parts Of Stacked Volume Of Earth After Reduction By 20% : 1 Part Of Stacked Volume Of Manure After Reduction By 8%) Flooding With Water, Dressing Including Removal Of Rubbish And Surplus Earth, If Any, With All Leads And Lifts (Cost Of Manure, Sludge Or Extra Good Earth If Needed To Be Paid For Separately) : Holes 90 Cm Dia, And 90 Cm Deep , Preparation Of Beds For Hedging And Shrubbery By Excavating 60 Cm Deep And Trenching The Excavated Base To A Further Depth Of 30 Cm, Refilling The Excavated Earth After Breaking Clods And Mixing With Sludge Or Manure In The Ratio Of 8:1 (8 Parts Of Stacked Volume Of Earth After Reduction By 20% : One Part Of Stacked Volume Of Sludge Or Manure After Reduction By 8%), Flooding With Water, Filling With Earth If Necessary, Watering And Finally Fine Dressing, Leveling Etc. Including Stacking And Disposal Of Materials Declared Unserviceable And Surplus Earth By Spreading And Leveling As Directed, Within A Lead Of 50 M, Lift Up To 1.5 M Complete (Cost Of Sludge, Manure Or Extra Earth To Be Paid For Separately) , Supplying And Stacking Of Well Decayed Cattle Manure At Site Including Royalty And Carriage Upto 5 K.M. Lead Complete (Cattle Manure Measured In Stacks Will Reduced By 8% For Payment). , Filling Mixture Of Earth And Sludge Or Manure In The Desired Proportion In Trenches, Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing And Fixing M. S. Tree Guard 45 Cm Square In Plan, Height 1.20 Metre Above Ground Level And 0.40 Metre Below Ground Level. The Vertical Members Shall Consist Of Four Nos. Angle Iron Of Size 25X25X3 Mm, 1.6 M Long, One At Each Corner And 8 Nos Flat Iron Of Size 25X3 Mm, 1.2 M Long. The Vertical Members Shall Be Welded To 4 Nos. 25X6 Mm M. S. Flats Placed Horizontally Around The Vertical Member Of The Cage. One Name Plate Of 1 Mm Thick M.S. Sheet Of Size 250X100 Mm Shall Be Welded To The Tree Guard Near The Middle Height And Lettered Cpwd/ Pwd/ Any Other Approved Name. The Tree Guard Shall Be Fixed To The Ground By Making Suitable Holes And By Embedding Four Corners Leg In The Ground, Including Refilling The Earth, Compaction Etc. Complete. The Tree Guard Shall Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Approved Brand And Manufacture Over A Coat Of Primer, Complete In All Respect. , Tree Plants Of Height 5-6 Such As Sevel/ Alestonia Big Poly Bag Including Cartage , Loading Unloading And Planting The Plant At Site . , Tree Plants Of Height 6-7 Such As Molsri 10 E. Pot Including Cartage , Loading Unloading And Planting The Plant At Site . , Ficuss Panda 2.5-3 In 10E.Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Shrubs 4-5 Height Such As Peli Kanier In 10 Earthen Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Chandni (Variegated) Of 2 To 2.5 Height 10E/Pots Well Grown.Including Cartage , Loading Unloading And Planting The Plant At Site . , Boganvillia Named Variety 2 To 3 In 10 E.Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Ashok Pendula 8-9 Height In 12 E. Pot Including Cartage , Loading Unloading And Planting The Plant At Site . , Ficus Benjamina 3 To 4 In 10 E.Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Plumaria Alba Round Leaves Well Grown 3-4 Branches 4-5 Height In 12 E. Pot Including Cartage , Loading Unloading And Planting The Plant At Site . , Hedges 1-2 Height Such As Putranjiva, Poly Bag.Including Cartage , Loading Unloading And Planting The Plant At Site . , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge.( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Manufacturing, Supplying Fixing Retro Reflective Overhead Signage Boards & Removing Of Existing Damaged Retro Reflective Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineer-In- Charge.(Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage, , Stone Tile (Polished) Work For Wall Lining Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Cement Slurry @ 3.3 Kg/Sqm Including Pointing In White Cement Complete 8Mm Thickgranite Of Any Colour And Shade , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:5:10 (1 Cement : 5 Coarse Sand (Zone-Iii): 10 Graded Stone Aggregate 40 Mm Nominal Size). , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , Providing And Laying Gang Saw Cut 18 Mm Thick, Mirror Polished Pre Moulded And Pre Polished Machine Cut Granite Stone Of Required Size And Shape Of Approved Shade, Colour And Texture In Footpath, Flooring Cut Granite Stone Of Required Size And Shape Of Approved Shade, Colour And Texture In Footpath, Flooring In Road Side Plazas And Similar Locations, Laid Over 20Mm Thick Base Of Cement Mortar 1:4 (1Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement Mixed With Matching Pigment, Epoxy Touch Ups Etc. Complete As Per Direction Of Engineer-In-Charge. With Granite Stone Of Area Less Than 0.50 Sqm. , Providing And Fixing Bolts Including Nuts And Washers Complete. , Designing, Fabricating, Testing, Installing And Fixing In Position Curtain Wall With Aluminium Composite Panel Cladding, With Open Grooves For Linear As Well As Curvilinear Portions Of The Building , For All Heights And All Levels Etc. Including: (A) Structural Analysis & Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design. (B) Providing, Fabricating And Supplying And Fixing Panels Of Aluminium Composite Panel Cladding In Pan Shape In Metalic Colour Of Approved Shades Made Out Of 4Mm Thick Aluminium Composite Panel Material Consisting Of 3Mm Thick Fr Grade Mineral Core Sandwiched Between Two Aluminium Sheets (Each 0.5Mm Thick). The Aluminium Composite Panel Cladding Sheet Shall Be Coil Coated, With Kynar 500 Based Pvdf / Lumiflon Based Fluoropolymer Resin Coating Of Approved Colour And Shade On Face # 1 And Polymer (Service) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc (C) The Fastening Brackets Of Aluminium Alloy 6005 T5 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing The Item Includes Cost Of All Material & Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminium Composite Panel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminium Composite Panel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work For Acp Cladding Is Payable Under The Relevant Aluminium Item.S The Contractor Shall Provide Curtain Wall With Aluminium Composite Panel Cladding, Having All The Performance Characteristics All Complete , As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer-In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Composite Panel Cladding (Including Width Of Groove) Shall Be Measured In Sqm. Up To Two Decimal Places. , Providing & Fixing Backlit Signage Of Size 80 Ft X 3Ft Made Out Of Acp Of 3Mm Thickness With Ms Framework With 3D Cut Letters On The Acp. Having Ip 68 Rated Samsung Chip Leds Of 10000K With 140Lumens Per Feet For Brightness & Uniform Illumination With No Hotspots Including Material, Labour Charges, Freight Charges Etc Complete With 1 Year Warrenrty On Complete Product And Per Direction Of Engineer-In-Charge. , Supplying And Installation Testing And Commossioning Of 40 Watts Smart Intergarated All In One Solar Light Of Highty Effeciency Solar Panel Led Light And Long Lite Po4 Battery With High Effieciency Micriprocessor-Based Charge Controller Per Motion Sensor And Compact In Size Complete Etc As Required Make Bajaj /Volmont/Phillips/Lysaght/Havells). , Supplying And Installation Led Wall Light , Energy Saving, Decorative Ip 66 Led Up-Down Luminaire With Wall Surface Mounting Using Cob Led As Light Source As Required Make Bajaj /Volmont/Phillips/Lysaght/Havells). , Supply Of 150 Led Luminaire For Flood Light With Warranty For Free Replacement 1 Year 140 To 270 Volts Ac At 50 Hz+/-2 Hz With Auto Cutt Off At Below 120V, Including All Wiring, Circuity, Switch & Installation (Make For Led Street Light Bajaj, Cropton, Orient Or Equivalent). , Providing, Fixing Erection And Testing Of 3G.I. Pole Decorative Street Light Of 6 Mtr. Hight Having Base Plate Welded On Bottom Of Pipe Of Suitable Thickness With Foundation Including Excvation Shuttering And Cement Concrete Complete Etc As Required And As Per Direciton Of The Engineer-In-Charge At Site. , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications ,Duplex Maps D01 As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Combination Set 3 In 1,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Frp Wave Slide 2.1 Mtr., As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Toddler Swing, As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Standard Swing,,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Circular Swing,Simply Go Round,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Half Round Net,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Std. See-Saw (Double),As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Spring Rider Jumboas Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil. Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia , Supplying And Filling In Plinth With Sand Under Floors Including, Watering, Ramming Consolidating And Dressing Complete. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Ill) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , (74) Centring And Shuttering Including Strutting, Propping Etc. And Removal Of Form For (74.I) Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. , (74.Ii) Suspended Floors, Roofs, Landings, Balconies And Access Platform. , (74.Iii) Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , (74.Iv) Columns, Pillars, Piers, Abutments, Posts And Struts , Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide , Weather Shade, Chajjas, Corbels Etc., Including Edges. , Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc., Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.5 M, For Every Additional Height Of 1 Metre Or Part Thereof (Plan Area To Be Measured). Suspended Floors, Roofs, Landing, Beams And Balconies (Plan Area To Be Measured) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo -Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying Damp-Proof Course 50 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Lll) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Of Colour Black, Cherry/Ruby Red Or Equivalent , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Stone Slab Of All Colour And Texture Except Black, Cherry/Ruby Red Area Of Slab Upto 0.50 Sqm , Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide Pa 6 Grade Sleeve, Including Drilling Of Hole In Frame , Concrete/ Masonry, Etc. As Per Direction Of Engineer-In-Charge.10 X 120 Mm , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings /Wooden Frames With Rawl Plugs Screws Etc. , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Oarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sgm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To 1S: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) : 100X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) : 125 Mm , Providing And Fixing Is : 12817 Marked Stainless Steel Butt Hinges With Stainless Steel Screws Etc. Complete : 125X64X1.90 Mm , Providing And Fixing Aluminium Sliding Door Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc. Complete :250X16 Mm , (90) Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : (90.I) 150X10 Mm , (90.Ii) 100X10 Mm , (91) Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : (91.I) For Fixed Portion Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately).Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item) :With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On Both Sides. , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors, Including Cost Of Cutting Floors, Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mmthickness , Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia,3.0 Mm Thick & 2100 Mm Long With Ss Screws Etc .Complete As Perdirection Of Engineer-In-Charge.Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar , Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations:(E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge:With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : In 75X75Mm Deep Chase , Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1Mx1Mx400Micron, Finished With 12Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement Rounding The Edge Sand Making And Finishing The Outlet Complete. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion.(I) Single Socketed Pipes.110 Mm Diameter , (101) Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion. (101.I) Coupler 110 Mm , Single Tee With Door 110X110X110 Mm , Bend 87.5° 110 Mm Bend , Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete 110 Mm , Providing And Fixing Rectangular High Density Polyethylene Water Storage Loft Tank With Cover, Conforming To Isi : 12701, Colour Of Opaque White Or As Approved By Engineer-In-Charge. The Rate Includes Making Necessary Holes For Inlet, Outlet & Over Flow Pipes. The Base Support Including Fittings & Fixtures For Tank Shall Be Paid Separately. , (104) Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge Internal Work - Exposed On Wall (104..I) 15 Mm Nominal Dia Pipes , 20 Mm Nominal Dia Pipes , 25 Mm Nominal Dia Pipes , (105) Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. (105.I) 15 Mm Nominal Dia Pipes , (105.Ii) 20 Mm Nominal Dia Pipes , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :Range Of Three Urinal Basins With 10 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible 40 Mm Dia , Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms , Providing And Fixing Ptmt Shelf 440 Mm Long, 124 Mm Width And 36 Mm Height Of Approved Quality And Colour, Weighing Not Less Than 300 Gms , (114) Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) : (114.I) 25 Mm Nominal Bore , (114.Ii) 20 Mm Nominal Bore , (115) Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : (115.I) 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length 15 Mm Nominal Bore , (117) Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) (117.I) 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Ptmt Stop Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 86Mm Long. Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt, Push Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 98Mm Long. Weighing Not Less Than 75 Gms. , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 : 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15Mm Nominal Bore , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement : 6 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix 1:4 (1Cement: 4 Fine Sand). , 6 Mm Cement Plaster Of Mix : 1:3 (1 Cement: 3 Fine Sand) , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour :New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) , Glassfibre Reinforced Concrete For Cladding And Jali (Polished And Machine Cut) Of Thickness 12 Mm For Wall Lining (Veneer Work) Backing Filled With A Grout Of 12Mm Thick Average In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Marble Dust) With An Admixture Of Pigment To Match The Granite Shade (To To Be Secured To The Backing By Means Of Fastners Which Shall Be Paid For Seprately). Granite Flamed Finish Of Any Colour And Shade Area Of Slab Above 0.50 Sqm , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sqm. Mm F.R. L.S. Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet Suitable Size ;M.S. Box And Earthing The Point With 1.5 Sq.Mm Fr L.S. Pvc Insulated Copper Conductor Single Core Cable As Required (Group C). , Wiring For Circuit/Sub Main Wiring Along With Earth Wire With The Following Sizes Of Fr L.S. Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Steel Conduit As Required. A) 2X2.5 Sq.Mm + 1X2.5 Sq. Mm Earth Wire. , B) 2X6 Sq. Mm + 1X6 Sq. Mm Earth Wire , Wiring For Light /Power Plug With 2X4 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit Along With 1 No. 4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Supplying And Fixing Metal Box Of 150Mm X75Mmx60 Mm Deep (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 3 Pin 5/6 & 15/16 Amps Socket Outlet And 5/6 Amps Piano Type Switch, Connection, Painting Etc. As Required For Light Plugs To Be Used In Non Residential Building. , Earthing With G.I. Earth Pipe 4.5 Metre Long 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/Coke And Salt As Required. , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Single Pole & Neutral , Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. 200 Mm X 250 Mm X 60 Mm Deep , Supplying & Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts On Surface/Recess, Complete With Tinned Copper Bus Bar, Earth Bus Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Power Painted Including Earthing Etc. As Required (But Without Mcb/Rccb/Isolator) 12 Way, Double Door.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
31.
Educational and Research Institute #9854990 AOC
Tender For Mass Flow Controller / Gas Flow Controller
Contract Date: Mar 21, 2026 Contract Value : 3.39 Lakh
Government Departments No of Bidders 3
Uttarakhand View Result →
32.
Educational and Research Institute #9692021 AOC
Bids Are Invited For Mass Flow Controllers (Q3) Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 1.48 Lakh
Government Departments No of Bidders 4
33.
Educational and Research Institute #9692019 AOC
Bids Are Invited For Mass Flow Controllers (Q3) Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 1.48 Lakh
Government Departments No of Bidders 4
34.
Educational and Research Institute #9680996 AOC
Bids Are Invited For Trainer On Basic Digital Electronics I E Logic Gates , Trainer On Power Suppliers Half Wave Rectifier , Scr Driven Or Controlled Power Supply Trainer , Potentiometer Or Thermocouple Test Set , Auto Transformer , Calibration Test Bench For Ac And Dc Voltmeter , Bourdon Tube Type Gauges Of Various Ranges , Dead Weight Tester And Comparator , Differential Pressure Transmitter Electronic- Hart Or Field Bus Type , Pressure Transducers Training Kits , Experimental Set Up For Pressure Measurement , Hart Device Communicator And Calibrator , Pneumatic Calibrator , Pressure Switches Of Various Ranges , P To I Converter And I To P Converter , Vacuum Tester With Pump , Simple Tank Quantity Meter , Impeller Type Flow Meter , Helical And Turbine Flow Meter , Magnetic Flow Meter , Vortex Flow Meter , Flow Control Loop Set With Flow Controller Recorder , Experiment Closed Loop Set Up Solid Flow Measurement And Control , Corioils Mass Flow Meter , Flow Nozzle , Static Pressure And Air Type Purge Type Level Indicator , Level Transmitter Interface Hart Compatible , Level Control Set Up With Transmitter And Level Recorder , Level Measurement Eequipments For Solid , Experimental Set Up For Measuring And Controlling Of Temperature , Paper Less Lcd Or Led Recorder Setup , Real Pid Controller Trainig Kit , Programmable Logic Controller , Hart Or Filed Devices , Hydrauilc Actuators , Different Type Of Control Valves Such As Gate Valves , Valve Positioner , Hart Or Filed Bus Final Control Elements , Data Acquisiton Syastem , Adc To Dac Cards , Digital I Or O Cards , Conductivity Meter And Tds Meter , Experimental Set Up For Online Conductivity Measurement , Experimental Set Up For Online Ph Measurement , Experimental Set Up For Online Dissolved Oxygen Measurement Total Quantity : 114
Contract Date: Ref. Documents Contract Value : 1.84 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
35.
Housing Urban and Rular Development #9668223 Technical Bid
Tender For Supply, Installation, Testing And Commissioning Of Board Room And Conference Room Equipments At New Admin Building Sector -96 Noida With 3 Year Warranty , Supply, Installation, Testing And Commissioning Of 108-Inch Full Hd (1920×1080) Cob Led All-In-One Display Engineered For High-Performance Av Applications. Should Offers A 16:9 Aspect Ratio, 800 Cd/M² Adjustable Brightness, 3840 Hz Refresh Rate, And A 25,000:1 Contrast Ratio, Delivering Vibrant Visuals With 170° Wide Viewing Angles. Constructed With A Die-Cast Aluminum Frame And Front-Access Maintenance, Should Supports Wall-Mount, Mobile Stand, And Ceiling Installations. The System Should Runs On Minimum Android 13.0 With An Octa-Core Processor, 8Gb Ram, And 64Gb Storage, Featuring Dual-Band Wifi 5/6 And A Comprehensive Set Of Input/Output Ports Including Hdmi, Usb, Lan, And Spdif. Should Have Built-In 12W×2 Speakers And A Rated Lifespan Exceeding 100,000 Hours Make It Suitable For Long-Term, Scalable Deployments In Professional Environments.Cpu Octacore : Cortex A73*4+A53*4,Input Ports-Hdmi In*2,Spdif*1,Usb2.0*1,Usb 3.0*3,Usb-B*1,Lan*1,Output Audio Out*1,Lan*1, Wifi 5+ Wifi 6 (Dual Wifi).Bluetooth 5.0, Certifications: Copy Of Valid Bis To Attach. Make - Delta / Barco / Samsung, Item - Led Video Wall , Supply, Installation, Testing And Commissioning Of Screen Size (Diagnoal) 75 Inch,Brightness (Cd/M²) Typical 700 Nits Or Higher,Response Time (Ms) 8 Ms Or Lower,Display Resolution (H X V Pixels) 3840 * 2160,Backlight Type Direct Led,Viewing Angle (Right/Left/Up/Down),Operating System (Built In) 178 Degree,Operating System (Built In) Android ,Hdr Compatibility Hdr10,Hlg,Dolby Vision, On-Board Storage (Gb) 32 Gb Or More,Haze % 45 % Or Higher,Color Gamut (Dci-P3) 92% Or Higher,Wi-Fi Direct, Wi-Fi Certified & Wireless Lan Yes,Chromecast & Apple Airplay Built In Yes,Hdcp2.3,Hdcp Ports And Connectivity Hdmi (4), Digital Audio Out (1), Usb (2), Ethernet (1),Power Consumption Not More Than 300 W,Weight Without Stand. Certifications: Copy Of Valid Bis To Attach. Make - Samsung / Panasonic / Sony, Item - Led Display , Supply, Installation, Testing And Commissioning Of Motorized Retractable Monitor Lift Should Feature An Integrated 15.6-Inch Led Ips Touchscreen Housed In A Full Aluminum Alloy Enclosure With A Minimum 5Mm Brushed Panel For Durability And Premium Finish. The Display Should Support Full Hd Resolution (1920×1080) In A 16:9 Format, With Wide Viewing Angles Of At Least 170° Horizontal And 160° Vertical. It Should Deliver 16.7 Million Colors (10-Bit), A Brightness Of 300 Cd/M², Contrast Ratio Of 1100:1, And A Response Time Of 16 Ms At 60Hz. Touch Functionality Should Be Included To Enable Interactive Control And Seamless User Engagement. The Screen Tilt Should Be Electrically Adjustable Between 0 To 30 Degrees For Ergonomic Viewing. The Unit Should Provide Hdmi, Usb, And Rs232 Installation Of Connectivity For Integration With Av Control Systems. It Should Operate At Noise Levels Below 15 Db And Support A Service Life Exceeding 20,000 Cycles. Available Finishes Should Include Brushed Aluminum Silver Or Matte Black. Power Consumption Should Not Exceed 170W. Etc Complete As Per Specification Make - Albiral/ Solvision / Soltec, Item - Motorized Retractable Monitor Lift , Supply, Installation, Testing And Commissioning Of 7.5 -Inch Dual Side Display In Horizontal Orientation. Resolution Of Display Should Be 480 X 800 ( H X W). Connectivity - Ble5.2. Builtin Battery Life Should Not Be Less Than 2 Years With Minimum 4 Changes Per Day With Standard Table Top Accessories. Make - Televic / Panasonic / Brahler, Item - Electronic Name Plate , Central Conferenec Engine With Recording Capabilities. Integrated Dynamics Processor With Programmable Threshold, Ratio, Attack And Release Of Noise Gate, Agc And Limiter Functions. The Engine Should Support Following Microphone Mode: › Direct Speak. › Request. › Group Discussion. › Operator. › Hands-Free. Unit Should Have On/Off Power Botton And Volume Dial To Adjust System Volume. Dlp Switch To Enable And Disable Power To Conference Ports. Browser Based Configuration And Monitoring Software Included. 2 X Power Connectors, 4 X Conference Network Ports, 1 X Usb 2.0, 1 X Lan Port, 1 X Balanced Xlr Audio Input, 1 X Balanced Xlr Audio Output, 2 X Unbalanced Cinch Audio Inputs, 2 X Unbalanced Cinch Audio Outputs. Should Have 2 Redundant Dante Ports. Recording Capabilities: Internal (8Gb) Or External Storage Usb 2.0 (Upto 500Gb) And File Download (Mp3) With Single Push Button To Start Or Stop Recordings And Indicator Led. Audio Routing, Network Monitoring, Built-In Diagnostics Application And Camera Control (Look At Me) Capability. The Engine Should Be Capable Of Shielded Network Loop (Non-Propietory) Cabling, Maximum 80 M Between Two Conference Device And Single Loop Permits A Total Cable Length Of 400 M Or More And Automatic Redundance Using Additional Controller. It Shall Have Flexibility To Attach Wireless Conference Units As Well If Required In Future. Unit Should Support Voting & Interpretaion. For Interpretation, Default Of 11 Languages + Floor (Can Be Extended To 63 + Floor Compatibility). Option To Add Dante Network Card For Audio Over Ip In Case Required For Future Seamless Integartion. 19 Rack Mountable. 48V/5.62A Power Supply Included. Certification: Ce Make - Bosch/Televic/ Braheler, Item - Audio Conference Engine/ Controller , Integrated Flush Mount Delegate Conference Unit With Speaker Built-In And With Removable Microphone Capability. Tactile Microphone Push Button With Integrated Led. Built-In High-Quality Loudspeaker, Minimum 1W Or Better. Frequency Response: 200-20,000 Hz Or Better. Speaker Shall Automatically Muted When The Microphone Is Active, To Prevent Acoustic Feedback. Available In Custom Colors, Lengths, Finishes. Construction :Steel 3.5 Mm Stereo Jack Sockets For Headphone Connectivity. Connectivity: › 2 X Rj 45 Ethernet Port (In/Out - Interchangeable). › Loop Through, Daisy-Chain Cabling (Non-Proprietary). Usb C Push & Lock Socket To Connect A Removable Microphone. Microphone Input: › Dynamic Range : 90 Db Or Better › Frequency Response: 20-20,000 Hz Or Better › Thd: 0.1% Or Better Certification: Ce; Bis Make - Bosch/Televic/ Braheler, Item - Delegate Audio Conference Unit , Integrated Flush Mount Chairman Conference Unit With Speaker Built-In And With Removable Microphone Capability. Unit With Priority And Next-In-Line Configuration. Priority Button Silences All Delegate Microphones And Allows Only The Chairperson To Speak. Next-In-Line Button Gives The Floor To The Next Speaker In A Waiting List Of Speakers Who Requested To Speak. Tactile Microphone Push Button With Integrated Led. Built-In High-Quality Loudspeaker, Minimum 1W Or Better. Frequency Response: 200-20,000 Hz Or Better. Speaker Shall Automatically Muted When The Microphone Is Active, To Prevent Acoustic Feedback. Available In Custom Colors, Lengths, Finishes. Construction :Steel 3.5 Mm Stereo Jack Sockets For Headphone Connectivity. Connectivity: › 2 X Rj 45 Ethernet Port (In/Out - Interchangeable). › Loop Through, Daisy-Chain Cabling (Non-Proprietary). Usb C Push & Lock Socket To Connect A Removable Microphone. Microphone Input: › Dynamic Range : 90 Db Or Better › Frequency Response: 20-20,000 Hz Or Better › Thd: 0.1% Or Better Certification: Ce; Bis Make - Bosch/Televic/ Braheler, Item - Chairman Audio Conference Unit , Short Stem Removable 98Mm Microphone Is Equipped With Usb C-Based Push And Lock Connector Microphone Length: 97 × 33 × 33 Mm. Polar Pattern: Cardioid. Max Special @ 1Khz: 105 Db Special Or Better. Signal-To-Noise Ratio Referred To 1 Pa: 74 Db Or Better. Sensitivity @ 1 Khz : -35 Dbv/Pa Or Better. Frequency Response: 125 To 15000 Hz Or Better. Microphone With Ring Indicator To Light Up Red When Active And Green When In Request. Usb-C-Based Microphone Connector. Connection: Push & Lock. Certification: Ce Make - Bosch/Televic/ Braheler, Item - Removable Microphone , Supply, Installation, Testing And Commissioning Addtional Power Supply For Conference Units, Output Should Have 200W Or More Must Have Short Circuit Protection,Over Voltage Protection,Over Power Protection ,Over Temperature Protection , Must Have Bis Certifications.Oem Must Have Presence In India , Need To Submit The Incorporation Certifications During Technical Bid. Make - Bosch/Televic/ Braheler, Item - Additional Power Supply Unit For Microphone Controller , Supply, Installation, Testing And Commissioning Of Audio Routing Software It Allows You To Create Custom Configurations, Manage Inputs Outputs And Switch Between Configurations For Dante Channel Create New Custom Configurations ,Activate A Prepared Audio Configuration Edit, Duplicate And Delete A Configuration ,Switch Between Existing Configurations Visualize The Various Routing Groups As A Matrix ,Set Routing Options Manage All Inputs And Outputs (Auxiliary And Dante Levels) ,Set Mix Minus And Number Of Mix Minus Groups ,Route Translation Channels To Dante Select Microphones Or Loudspeakers As Always Active For User Input And Output Groups In Customs Configurations.Oem Must Have Presence In India , Need To Submit The Incorporation Certifications During Technical Bid As Per Specification. Make - Bosch/Televic/ Braheler, Item - All Required Softwares For Conference System , Supply, Installation, Testing And Commissioning Of Ceiling Speaker A) Driver: Two Way Driver Size: 6.5 Coaxial B) Rms Power: Not Less Than 70 Watt Or More C) Nominal Impedance: 8 Ohm Or 12 Ohm, 16 Ohm D) Transformer Taps: 60W/ 30W / 15W E) Frequency Range : Range (-10 Db) 75 Hz -19 Khz F) Dispersion - 110 Degree Or Better G) Sensitivity: Minimum 89 Db & Special 109 Db H) Certification Ce , En, Rohs /Ul Required Make - Jbl/ Qsc/ Bose, Item - Ceiling Speaker , Supply, Installation, Testing And Commissioning Of Four Channel Power Sharing Amplifier With Inbuilt Dsp And Dante. A) No. Of Channel: 4-Channel B) Wattage: Not Less Than 125 Watt Power Amplifier@ 8 Ohms. C) Class : Class D Type D) Dsp : Should Have Rj45 Connectivity. E) Power Output : Minimum 4X 125W @ 8 Ohms ,1 X 500 W @ 8 Ohms Better 1 X 550W , 1X500 @ 4 Ohms Or Better . F) Signal To Noise Ratio : 104 Db , 113 Db Dante Or Better, G) Frequency Response : 20 Hz To 20 Khz H) Input Impedance: 20 K? Balanced (+/- 5%) I) Protection: Thermal And Dc Protection. J) Thd +N .1%. Make - Crown/ Qsc/ Bose, Item - Power Amplifier , Supply, Installation, Testing And Commissioning Of Active Self Powered Column Speaker : A) System Type: Active Self Powered Colum Loudspeaker Array B) Driver Size: Min. 10 X 4 Driver Or Better C) Rms: 8X40 W @ 4 Ohms D) Nominal Impedance: 4 Ohms E) Special Peak: Not Less Than 89 Db F) Frequency Range: 130Hz - 18Khz G) Sensitivity: Not Less Than 89 Db I) Enclosure: Oem Mounting Bracket Included, Construction : Aluminium, Ce Certification Or More. It Is Inclusive Of Detailed Conditions, Re- Doing Till The Satisfaction, Getting The Desired Functionality Complete. Make - Jbl/ Qsc/ Bose, Item - Active Self Powered Column Speaker , Supply Of Loudspeaker Shall Be A 32-Inch (800 Mm) Slim Column Design With Wide 160° Horizontal And 60° Vertical Coverage, Incorporating A Built-In 10° Down-Tilt For Optimal Listening Area Coverage When Mounted Flush To A Wall. It Shall House Four 5 In × 2.25 In (125 Mm × 55 Mm) Racetrack Woofers And Two 0.8 In (20 Mm) Tweeters, Delivering A Frequency Response Of 85 Hz - 20 Khz, Peak Special Of 116 Db, And Continuous Power Handling Of 150 W (600 W Peak, 2 Hrs) With 300 W Program Rating. The Unit Shall Include A 60 W Multi-Tap Transformer For 70 V/100 V Operation With Taps At 60 W, 30 W, 15 W (Plus 7.5 W At 70 V) And An 8 O Bypass Mode. Etc Complete As Per Specification. Make - Jbl/ Qsc/ Bose, Item - Loudspeaker , Supply, Installation, Testing And Commissioning Of 19 1Ru Processor Mainframe With Sixteen User-Configured Card Slots . Selectable 48 & And 96Khz Sampling Rates. Integrated License-Activated Aec. Dual-Core Processing 40-Bit Floating Dsp. Rear Panel Includes An Ethernet Module With An Rj45 Connector And Dante Channel 64X64 Installation Of Channels Of Dante Network Audio. 1 Rj45 Dante And Single Rj45 Ethernet Connectors. 12 Mic/Line Inputs, 8 Line Output . 32-Bit Digital To Analog Converters , Rs 232 Port, Usb Audio Port For Software Vc Application As Required As Per Specification. Make - Solaro/Xilica/ Bss/ Biamp, Item - Digital Signal Processor , Supply, Installation, Testing And Commissioning Of Wireless Digital Handheld Microphone With 18 Or More Channel, Rf Output 100Mw Or More, Super Cardiod Pickup Pattern, Frequency Range : 1880 To 1930 Mhz, Connectivity : Rj-45, 256-Bit Aes Encryption (Specifications Includes Single Microphone Set Of Transmitter And Receiver) With Charging Tray Etc. Complete As Required. Make - Sennheiser/ Shure/ Bosch, Item - Wireless Handheld Microphone , Supply, Installation, Testing And Commissioning Of A Compact, Modular Android-Based Video Conferencing Codec Powered Exclusively Via Poe+ (Ieee 802.3At Class 4) To Ensure Simplified Rack Or Display Mounting Without External Power Supplies. The System Must Support Native 4K Ultra Hd (3840 X 2160) Resolution On Dual Displays And Utilize H.264 Avc And H.265 Hevc Video Compression Standards. Integrated Hardware Interfaces Shall Include One Hdmi Video Input, Two Hdmi Video Outputs, One Usb Type-C Port Supporting Displayport Alt Mode And Usb Device Mode, One Usb 3.0 Type-A Port, And A Dedicated Link-Local Network (Lln) Rj45 Port For The Direct Connection Of Ip-Based Audiovisual Peripherals. The Unit Must Feature Built-In Wi-Fi 6 (802.11Ax) And Bluetooth 5.2 Connectivity, Support Enterprise-Grade Security Protocols Including 802.1X And Aes 128/256 Encryption, And Provide Management Capabilities Via Cloud-Based Platforms And Standard Rest Apis. And Comes With A 3-Year Oem Warranty. Make - Hp-Poly / Avaya / Cisco, Item - Video Conference Codec System , Supply, Installation, Testing And Commissioning Of A Professional 4K Ptz Camera Featuring A High-Sensitivity 1/2.3-Inch Type Cmos Sensor And An Advanced Image Processor Capable Of Delivering 4K Uhd Resolution At 30Fps And Full Hd At 60Fps With 4:2:2 10-Bit Color Sampling. The Unit Shall Be Equipped With A Built-In Lens Offering A Minimum 20X Optical Zoom (Approx. 29.3 Mm To 601 Mm Equivalent) And Must Utilize A Hybrid Auto Focus System And Optical Image Stabilization To Ensure Image Stability And Clarity. The Pan-Tilt Mechanism Shall Provide Precise Movement With A Pan Range Of At Least ±170° And A Tilt Range Of -30° To +100°. For Connectivity, The Camera Must Support Simultaneous Video Output Via Hdmi, Ip, And Usb-C (Uvc Standard) To Facilitate Web Conferencing. The System Should Have Native Support For Advanced Streaming Protocols Including Ndi|Hx, Srt, Rtmp/Rtmps, And Rtsp, As Well As Standard Serial And Ip Control Protocols. The Device Shall Include A 3.5 Mm Microphone Jack For Audio Embedding And Must Support Power Delivery Via Poe+ (Ieee 802.3At) For Single-Cable Installation. Etc Complete As Per Required. Make - Aver / Canon / Sony, Item - Ptz Camera , Supply, Installation, Testing And Commissioning Of Multicamera Speaker Tracking Station With Operation System Embedded Linux. Device Should Be Able To Process Four Network Camera Source And Two Physical Content Sources. Device Must Have Video Input Interface Such As 2 X Hdmi/Vga, 4 X Full Hd Network Camera With Resolution Range (Inputs) Hdmi : 480I~1080P60 Vga : 480I~1080P60 Rtp/ Rtmp/ Rtsp, Max. 1080P ,Device Must Have Video Output 1 X Hdmi 1080P60, 1 X Vga 1080P60.Device Must Support Overlay Images Multiple For User Defined. Device Must Support Video Output Layout - Multiple Layouts For Pre-Defined, Including Full Screen / Picture-In-Picture / Picture-By Picture / Multi-Channel Split Screen, Should Support Camera Control Visca/ Pelco-D/ Pelco-P/ Onvif Profile S/ Visca Over Ip.It Should Support Mouse Device Through Usb Interface Connection ,It Should Support Rs-232 Port And Tcp Api Command For System Integration.It Should Have A Provision Of Output Switching According To The Setting Of Push-To-Talk Buttons With Compatible Conference Microphone System ,It Should Have Built-In Web-Based Admin Backstage. Sending Control Command Through Tcp Api Etc Complete As Per Required. Make - Arec/ Amx/Ordain, Item - Multicamera Tracking Device , Supply, Installation, Testing And Commissioning Of 4K Hdmi To Usb Capture Card , Hdmi 2.0 Support - Hdmi Video Input Supports Resolutions Up To 4096×2160P@60 4:4:4, Hdr, And 10-Bit Per Channel Deep Color ,Usb 3.0 Capture - Uvc Video Output Supports Resolutions Up To 3840×2160P@30Fps ,Audio Input Embedded - Audio Input Support Includes Analog Stereo Audio And Hdmi Embedded Audio Support For Popular Os Platforms - Windows 10 (64-Bit), Macos (10.12 Or Newer) Uvc Software Compatible - Supports Zoom, Teams, Webex, Skype, Slack, Discord, Bluejeans, Gotomeeting, Vlc, And More As Per Specification. Make - Kramer/ Blustream/Amx, Item - Hdmi To Usb Capture Card , Supply, Installation, Testing And Commissioning Of All-In-One Conferencing And Collaboration Engine Shall Be A Compact, Windows-Based Unit Designed For Continuous Operation, Supporting Popular Uc Platforms Such As Microsoft Teams, Zoom, And Webex Without Additional Hardware. It Shall Feature Wireless Content Sharing Via Airplay And Miracast, Built-In Document Viewing, And Access To Network Drives For Local Or Remote Content Retrieval. Hardware Specifications Shall Include An Intel® I5 Processor Or Higher, Minimum 8 Gb Ram Or More, 256Gb Ssd Storage Or More, Hdmi Output Supporting Up To 4K @ 60 Hz, Multiple Usb-A And Usb-C Ports, And Gigabit Ethernet. The Unit Shall Integrate Seamlessly With Cameras, Microphones, Dsps, Offering Quick Boot, Wake-On-Lan, And Auto Power-On Functions.Supply Along With Wireless Keyboard & Mouse Etc Complete Required As Per Specifications. Make - Intel/ Dell/ Ordain, Item - Soft Vc Codec Mini Pc , Supplying, Installation, Testing & Commissioning Of Of Cabling Cubby With 2 Power 4 Pass Through Cable Manager With 1 Hdmi, 1 Usb C, 1 Lan Cable And Usb Charging With 18W & 65 W Etc. Make - Extron / Amx/ Kramer, Item - Cable Cubby , Supply, Installation, Testing And Commissioning Of 4K60 4:4:4 Video Over Ip Encoder, Wall Plate With Poe Support, Should Have Hdmi 2.0 & Hdcp 2.2 & Edid Management, Shall Have Hdr10+, Should Have Minimum 1X Hdmi And 1X Usb-C Input And A Usb-C Input Must Support Both Audio, Video And Usb 2.0 Transport Of Full-Bandwidth Usb 2.0 Signals On A Single Connector, Support Embedded Audio On Hdmi, Usb-C Or Analog Stereo, 8Ch Pcm And Stereo 2-Channel Analog Audio Formats , Latency Should Be Less Then 17-Ms At 60 Fps, Must Have High Security Network Support Including Multicast, Vlan Tagging And Qos, Encoder Should Support Poe/Poe+ Standards And Low-Power Mode For Energy Savings, Should Have Open Standard Control Api. Regulatory Compliance Ul, Fcc, Jitc And Ce. Make- Extron/ /Amx /Lightware, Item - Encoder , Supply, Installation, Testing And Commissioning Of 4K60 4:4:4 Video Over Ip Decoder, Wall Plate With Poe, Should Have Hdmi 2.0 & Hdcp 2.2 & Edid Management And Decoder Must Have Built-In Scaler To Up-Scale And Downscale Encoder Streams To Support Display Resolution Natively, Shall Have Hdr10+, Should Have Minimum 1X Hdmi Output Port, And 2 X Usb 2.0 Ports For Hid And Usb Peripheral Support, Should Have Built-In 1 X Ir And 1 X Rs232 Control Ports, Should Have Analog Stereo, 8Ch Pcm And Stereo 2-Channel Analog Audio Port, Latency Should Be Less Then 17-Ms At 60 Fps, Must Have High Security Network Support Including Multicast, Vlan Tagging And Qos, Decoder Should Support Poe/Poe+ Standards And Low-Power Mode For Energy Savings, Should Have Open Standard Control Api. Regulatory Compliance Ul, Fcc, Jitc And Ce. Make - Extron/ /Amx /Lightware, Item - Decoder , Supply, Installation, Testing And Commissioning Of A/V Controller, Controller Must Have Minimum 1 X Rs232/Rs422/Rs485 Serial Port, 3 X Rs232 Serial Ports, 4 X Ir/One-Way Serial Ports, 4 X Relay Ports, 4 X Gpio Ports, Controller Must Have One Lan Port For 10/100 Base-T For Ethernet Communication, Controller Must Have Dual Lan Ports To Create An Isolated Network For Av Controlled Devices. Controller Must Have Minimum 4Gb Of On-Board Ddr3 Ram, It Must Have A Commercial Grade 8Gb Emmc Non-Volatile Memory Storage Chip, Providing Reliability In High-Access 24/7 Environment, Controller Must Have A Usb-A Host Port Available For Use With Mass Storage Devices For Convenient Logging Capabilities As Well As To Connect Other Devices Such As The Ir Receiver To Add Ir Controls As An Input To The System, Controller Must Supports Ipv6, Must Have 802.1X And Https Security, Controllers Without Support Of Ipv6 And Advanced Security Integration Will Not Be Accepted, Controller Must Support Unlimited Number Of Scripts Simultaneously, Standard And Flexible Programming, Supporting Advance Scripting In Multi Standard Languages, Also Natively Support A Flow-Based Programming Environment Like Low-Code/ No-Code Environment, Controllers Lacking The Standard Architecture, Lacking Flexibility Of Programming Will Not Be Accepted, Controller Must Support Harsh Operating Temperature 0° C To 50° C (32° F To 122° F) To Avoid Hanging And Failures, Controller Not Meeting The Operating Temperature Requirement Will Not Be Accepted,Controller Must Have Regulatory Compliance : Ices 003, Ce En 55032, Aus/Nz Cispr 32, Ce En 55035, Ce En 62368-1, Iec 62368-1, Ul 62368-1, Vcci Cispr 32, Rohs / Weee Compliant And Jitc. Make - Extron/ Lightware/Amx, Item - Av System Master Controller / Processor , Supply, Installation, Testing And Commissioning Of Wireless Touch Panel Minimum 10 Inch Size Having 64 Gb Inbuilt Menory With Wifi. All Complete With Required Docking Station And Software License For 3Rd Party Integeration. Make - Apple / Samsung / Amx, Item - Touch Panel , Supplying, Installation, Testing & Commissioning Of Wireless Presentation System. Should Have Support For Operating System Windows 10 And Higher Macos 11 (Bigsur) And Higher Android V9 And Higher Ios 12 And Higher,Video Outputs 4K Uhd (3840*2160) @ 30Hz. Hdmi 1.4B Or Usb-C Displayport 1.2 (Only Gen2) Audio Output Hdmi Usb 1 X Usb-A, 1 X Usb-C Or 2 App Desktop & Mobile Native Protocols Airplay, Google Cast, Miracast* Maximum Number Of Simultaneous Connections (With Buttons And/Or App) 32 Noise Level Max. 25Dba @ 0-30°C Max. 30Dba @ 30-40°C Authentication Protocol Wpa2-Psk In Stand Alone Mode Wpa2-Psk Or Ieee 802.1X Using The Network Integration Mode Wireless Transmission Protocol Ieee 802.11 A/G/N/Ac And Ieee 802.15.1 Reach Adjustable With Signal Strength Modulation; Max. 30M (100 Ft) Between Button And Base Unit Frequency Band 2.4 Ghz And 5 Ghz Frequency Band 2.4 Ghz And 5 Ghz (Dfs Channels Supported In Select Number Of Countries) Connections 1X Ethernet Lan 1Gbit 1X Usb-C 2.0 (Front); 1X Usb-A 2.0 (Front) - Only Gen2: 1X Usb-C 3.0 (Front); 1X Usb-A 3.0 (Front) (Peripheral Support) No Local View Yes Network Connection Lan & Wifi Etc Complete Required As Per Specifications. Make- Barco / Kramer / Wolflvision, Item - Wireless Presentation Device , Supplying, Installation, Testing & Commissioning Of Of 48 # 1G Base-T Copper Poe+ Ports ,04 # 1/10G Base-X Fiber Sfp+.Ethernet: Out-Of-Band 1G Port ,Console: Usb-C ,Storage: 2 X Usb-A ,Half-Width 1 Or 2-Unit 1U Rack Mount ,Cpu: Quad-Core Cortex-A57 Armv8 1.8Ghz 64-Bit Ram: 2 Gb Ddr4 ,Packet Buffer Memory: 16 Mb ,Flash: 512Mb Nand 8-Bit Ecc ,236W (Base) Poe Budget With Internal Psu ,Up To 1440W Poe Budget With 3 Psus(1 Internal + 2 Modular Psu) In Eps Mode ,Stack Height: 8 Switches Switching Fabric: 176 Gbps Line-Rate (Non Blocking Fabric) ,Throughput: 130.94 Mpps ,Forwarding Mode: Store-And-Forward Address Database Size: 16,000 Mac Addresses (48-Bit Mac Address), Network Switch Should Be Compitable With Av Over Ip Protocol. Etc As Per Specification. Make - Cisco/ Netgear/ Hp, Item - Layer 3/2 For Networking And Av Over Ip Switch , Supplying, Installation, Testing & Commissioning Of Dual-Band Wi-Fi 6 Router Delivers Speeds Up To 1500 Mbps Across The 2.4 Ghz And 5 Ghz Bands, Making It Ideal For Smart Homes And Small Offices. It Features Four High-Gain External Antennas For Extended Coverage Up To 2500 Sq. Ft., Along With One Gigabit Wan Port And Three Gigabit Lan Ports For Reliable Wired Connections. Advanced Security Protocols Like Wpa3 Ensure Safe Browsing, While Ai-Powered Features Such As Mesh Optimization, Traffic Management, And Parental Controls Enhance Performance And Usability. The Router Is Easy To Set Up Via A Dedicated Mobile App And Runs On A 12V/1A Power Adapter. Dual-Band Wi-Fi 6 Router Delivers Speeds Up To 1500 Mbps Across The 2.4 Ghz And 5 Ghz Bands, Making It Ideal For Smart Homes And Small Offices. It Features Four High-Gain External Antennas For Extended Coverage Up To 2500 Sq. Ft., Along With One Gigabit Wan Port And Three Gigabit Lan Ports For Reliable Wired Connections. Advanced Security Protocols Like Wpa3 Ensure Safe Browsing, While Ai-Powered Features Such As Mesh Optimization, Traffic Management, And Parental Controls Enhance Performance And Usability. The Router Is Easy To Set Up Via A Dedicated Mobile App And Runs On A 12V/1A Power Adapter. Make - D-Link/ Tplink/ Netgear, Item - Wireless Router , Supplying, Installation, Testing & Commissioning Of Hdcp Compliant Gold- Plated 1.8 Mtrs. Hdmi Cable Patch Cord Etc. Complete As Reqd. Make - Lintek/ Kramer/ Tasker, Item - Hdmi Cable , Supplying, Installation, Testing & Commissioning Of Type C To Type A Usb Cable 10 Mtr. As Per Specification. Make- Lintek/ Kramer/ Tasker, Item - Usb Cable , Supplying, Installation, Testing & Commissioning Of 2X16 Awg Twisted Loudspeaker Cable, Flame Retardant Pvc Avml Sheath, O.F.C. As Per Specification. Make - Kramer/ Tasker/ Belden, Item - Speaker Cable , Supply Of 2X0,35 Mm² (22Awg) Low Capacitance Supreme Microphone Balanced Cable ,Braided Shielding O.F.C. Tinned Copper Covering 90%. Operative Temperature -15/+70°C Etc Complete Required As Per Specifications. Make- Kramer/ Tasker/ Belden, Item - Microphone Cable , Supplying, Installation, Testing & Commissioning Of Cat-6 A Cable As Per Specification. Make - Legrand/ Commscope/ D-Link/ Derwiser, Item - Cat6/ Cat6a Cable, I/Os, Patch Panel, Face Plate, Panel Rack , Supplying, Installation, Testing & Commissioning Of Of 32 U Equipment Rack With Locking Wheel, Cooling Fan , Cable Manager Tray, Power Strip Etc As Per Specification. Make - Valrack/ D-Link/ Rtech/ Dynamic/Ordain, Item - Networking Rack , Skilled Manpower For Three Years Operation , Supplying And Fixing Of Acoustic Panel/Tile With Taper Edge Having Sizes 600X600/600X1200mm And Thickness Of 25 Mm Insulating Material Made From Fibers Of Glass Arranged Using A Binder Into A Texture Similar To Wool. The Process Traps Many Small Pockets Of Air Between The Glass, And These Small Air Pockets Result In High Thermal Insulation And Sound Absorption Properties. Panel Installed System Should Provide Absorption Coefficient Of A 0.94 @ 4000 Hz As Per Is:8225-1987 (Equivalent To Iso: 354-1985 & Astm 423-90). To Be Installed Direclty On Existing Gypsum Ceiing With Hidden Aluminium H Profile. Make - Baux, Himalyan Acoustics, Armstrong, Knauf, Item - Acoustics Panels/Tiles , Providing And Fixing Of Stretch Fabric Simple System With 600X1200x25mm Tile Made With Wood Fibre 1Mm Width Cement Composites Tile. Fabric Colour As Per Consultant/Client Choice. Acoustical Infill Of 300 Gsm Absorb Wool Thickness 10Mm Which Is Adhered To The Acoustical Panel On The Front Side. Then 12Mm Vinyl Tracks Are Screw Fixed On The 8 Mm Thick And 50Mm Wide Ply Strips. Then The Fabric Is Stretched Over The Vinyl Tracks. The Installed System Should Provide Nrc Of 0.74. Should Have Complied With Anti Bacterial Test As Per Jis-Z2801-2010. To Be Installed Directly On Walls Covered With Veneer And Ply. Make - Baux, Himalyan Acoustics, Armstrong, Knauf, Item - Stretch Fabric Panels
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2.70 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 5.35 Lakh
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : 4.35 Lakh
Government Departments No of Bidders 6
40.
Educational and Research Institute #9547414 AOC
Bids Are Invited For Mass Flow Controllers (Q3) Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 7.54 Lakh
Government Departments No of Bidders 1
41.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
42.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
43.
Agriculture #9519259 Technical Bid
Tender For Construction Of Divisional Office Building Vellore At Fsd Sevur Tamil Nadu Region (Recall).; 1 Civil ( S.No.1-96) Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as directed by Engineer-in-Charge. a) All kind of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Supplying and filling in plinth withsand under floors, including watering, ramming,consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Treatment of soil using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1)concrete of m30 grade withminimum cementcontent of 350 kg /cuma) All works upto plinth level 9 b)All works above plinth level upto floor V level 10 Centering and shuttering including strutting, propping etc. and removal of form for all heights.a) Foundations, footings, bases of columns. etc. for mass concrete 11 b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 c) Suspended floors, roofs, landings, balconies and access platform 13 d) Columns, Pillars, Piers, Abutments, Posts and Struts 14 Stairs, (excluding landings) except spiral-staircases 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a)Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a)Cement mortar 1:4 (1 cement :4 coarse sand) 19 12 mm cement plaster a) 1:6(1 cement: 6 fine sand) 20 15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:4 (1 cement: 4 fine sand) 21 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 22 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of the tile 600x600 mm 24 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved brand & manufacturer, in all colours & shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement & matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size b) Size of Tile 600x600 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a)Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 27 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 28 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.a) On steel work 29 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 30 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/ wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 33 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 34 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 35 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 37 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified 38 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof Silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately.Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3(ii)Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 39 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class Acategorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a)Frame size 50 x 125 mm 40 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) a)35 mm thick 41 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 42 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 43 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only 44 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters. 45 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 46 Providng & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes 47 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure ation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for cupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and formation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for ualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a ssure range 50 kpa to 240 kpa (35psi) upto 2000 mlNote:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 48 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 50 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 51 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 52 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.a)200 mm 53 Providing and fixing Godrej Stainless Steel Glass to Glass Round Lock 7780 complete as per direction of Engineer-incharge. 54 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 56 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and pair of lever handles of approved quality with necessary screws etc. complete. 57 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 58 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 59 Full ht. 75 mm. thk Solid Partitions/Semi Glazed Partitions with both side 12mm commercial plywood and 1mm thick Laminate & Providing Aluminium frame of size 50x50x1.8 mm thk (finished) comprising of horizontals and verticals at, 600 mm c/c ,vertically and horizontally fixed firmly to walls / floors / RCC roof etc. Alternate vertical members to go upto RCC ceiling and firmly fixed. Providing 8 mm thk. ISI grade plywood of approved make , finished / fixed with 1 mm thick laminate of approved make & shade fixed with adhesive , fixed on both sides of the partition framework. The laminate to be fixed with adhesive on both sides of the partition upto False ceiling level. 60 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer ofplaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 61 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 62 Providing & applying patterened texture work on extrenal wall with birla or equivalent brand putty on plastered surface as approved by Engineer-in-Charge, 63 Providing and fixing of FRP Security Cabin in Size of 2.5x2.5x2.5m with M.S frame structure and covered by FRP Pannel and FRP Pyramid shape Plane Roof. FRP Door thick - 20mm (6x2) With, ALdrop, Handel, & 3 Nos. SS Ingies.Inside & Outside writing Counter, Size- L-4x W-11Electrical Point- Inside &Outside Bulb Point, 1plug, 3 Switch,Cloth Hanger- 01Nos as per Engineer in Charge. 64 PLUMBING Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : A) W.C. pan with ISI marked white solid plastic seat and lid 65 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 225 mm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (Size 600x450x200 mm) 67 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 68 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 69 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 70 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 71 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions) 72 Providing and fixing toilet paper holder : C.P. brass 73 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Sand cast iron S&S as per IS-1729 74 Providing and fixing soil,waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 75mm dia 75 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Hubles centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 76 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 78 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal Inner dia Pipes 79 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes 80 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes 81 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 82 Providing and placing on terrace (at all floor levels) polythylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 83 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 84 EXTERNAL INFRASTRUCTUREConstruction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge. a)With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 85 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 86 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size of 100x0.375x0.20 87 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 88 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm 89 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 90 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 91 Fine dressing of the ground 92 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 93 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 94 Providing and stacking of Plumeria acutifolia of height 120-135 cm. with 2-3 branches in HDPE bag of size 30 cm as per direction of the officer-in-charge. 95 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 96 Washingtonia filifea palm stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bag 97 Electrical ( S.No.97-211) Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work3 1/2 X 120 Sq.mm 98 3 1/2 X 70 Sq.mm 99 4 X 25 Sq.mm 100 4 X 10 Sq.mm 101 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 102 150 mm width X 50 mm depth X 1.6 mm thickness 103 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 104 150 mm width X 50 mm depth X 1.6 mm thickness 105 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 106 150 mm width X 50 mm depth X 1.6 mm thickness 107 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 108 Supplying and fixing of light class G.I. pipe of 100 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective coveringUpto 35 sq. mm 110 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185sq. mm 111 Up to 35 Sq mm 112 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 113 Upto 35 sq. mm (clamped with 1mm thick saddle) 114 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as requiredAbove 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 115 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 116 Upto 35 sq. mm (clamped with 1mm thick saddle) 117 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) 118 3½ X 70 sq. mm (38mm) 119 4 X 25 sq. mm (28mm) 120 4 X 10sq. mm (25mm) 121 Supplying and fixing hot press molded SMC box of size 140x140x95 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of 3 way connectors of suitable rating ,providing and fixing 6A C curve MCB, terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required 122 Supplying and fixing of follwing way sueface / recess mounting vertical type , 415 V , TPN MCB distribution board of sheet steel, dust protected , duly painted , inclusive of 200 A tinned copper bus bar , common neutral link , earth bar , for mounting MCBs (but without MCBs and incomer ) as required4 way ( 4 + 12 ) , Double door 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 124 6 way (4 + 18), Double door 125 4 way (4 + 12 ), Double door 126 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 127 Triple pole 128 Supplying and fixing following rating, four pole, 415V isolator in the existing MCB DB complete with connection , testing and commissioning etc. as required 40A 129 63 A 130 Providing and fixing following rating and breaking capacity and pole MCCb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections , etc as required100 A, 30 KA, FP MCCB 131 Supplying & fixing suitable size GI box with modular plate and cover in fornt on surface or in recess including providing and fixing 25A modular socketoutlet and 25A modular SP MCB , Ccurve includingconnections , painting etc , as required . 132 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 136 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 137 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 138 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 3pin 5/6 A modular socket outlet and 5/6 modular swith connections etc.as required . 139 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 6pin 5/6 A & 15/16 modular socket outlet and 5/6 modular swith connections etc.as required . 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 141 3 pin 5/6 A socket outlet 142 15/16 A switch 143 6 pin 15/16 A socket outlet 144 Telephone socket outlet 145 RJ45 computer socket cat 6 146 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mm X 125mm) 147 6 Module (200mm X 75mm) 148 1 or 2 Module (75mm X 75mm) 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 150 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 151 2 run of cable 152 3 run of cable 153 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair 154 2 Pair 155 Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 156 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 157 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess For connections etc. as required. 158 Providing and fixing 6 SWG dia G.I. wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 159 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 160 Providing and fixing 4.00 mm dia copper wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 161 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick . base plate including holes etc. complete as required. 162 Jointing copper / G.I tape (with another copper / G.I tape, base of the final or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required 163 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required (For horizontal run) 164 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required(For vertical run) 165 Providing and fixing testing joint , made of 20 mm X 3 mm thick G.I. strip , 125mm long , with 4 Each. of G.I bolts, nuts, chuck nuts and spring washers etc. complete as required. 166 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required . 167 Supplying, installation, Testing and commissioning of 90W LED Street light fittingmade up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 in the existing streetlight pole with suitable clamps and nut bolts including giving connection etc., at site of work as required 168 Supplying, installation, Testing and commissioning of 36 watt 2X2 LED flat panel recess mounting luminaire with high brightness LED as light source, suitable for Armstrong/Grid ceiling and fixing on ceiling with suitable hanging chains, clamps and nut bolts including giving connection testing etc., at site of work as required 169 Supplying, installation, Testing and commissioning of 12 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 170 Supplying, installation, Testing and commissioning of 18 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 171 Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with Al body, PC diffuser and inbuilt driver along with Highly robust box type luminare suitable for single T8 LED tube and fixing on wall/ceiling by using necessary clamps etc., at the site of work as required 172 Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for single T8 LED tubelight and fixing on wall/truss by using necessary clamps etc. as required 173 Supply and fixing of7W LED surface mounted LED mirror light luminarie complete and fixing on wall by using necessary clamps etc., at the site of work as required 174 Supplying, installation, Testing and commissioning of 24 watt square surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 175 Supplying, installation, Testing and commissioning of 40 watt LED 5700K Post top lantern IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required 176 Supply and fixing of 10W pressure die cast aluminium housing Bulk Head LED fitting with IP66 protected withPVC unsheathed copper leads from terminals to the fitting and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 177 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR Item for BEE 5 star rated Ceiling fan with Brush Less Direct Current (BLDC) motor 178 Supplying and fixing of single phase, 230V,50Hz, 1800 rpm, 200mm dia sweep, 5 blade Exhaust fan with bird screen for protection against birds & Foreign material and fixing on the wall surface including giving connections etc. at site of work as required 179 Supply of 6 mtr high hot dipped galvanised octagonal poles with 130 mm bottom dia and 70 mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x16 mm thick along with 4 nos of M20x600 mm high J type 8 EN grade foundation bolts along with template to fix the pole to the foundation and supply of 1 mtr long hot dipped galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70 mm dia for mounting the street light fixture 180 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregrate 40mm nominal size) foundation including excavation and refliing etc. as required 181 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.2 TR 182 2.0 TR 183 2.8 TR 184 Supply, Installation, Testing and Commissioning of 1.5 Ton/4500 Kcal/hr, 5 Star Rating Inverter technology High wall split type Air Conditioner with minimum of 3 metre length of copper Refrigerant piping with insulation and electrical cable complete with indoor unit (IDU), Outdoor unit (ODU) suitable For 230V +10% of 50 Hz, single phase AC supply and Fixing on the wall surface including giving connections etc. at site of work as required 185 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 186 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required19 mm dia (OD) (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation 187 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 188 Supply and fixing of FP sheet enclosure on surface/recess along with 63A FP C curve MCB complete with connections, testing and commissioning etc. as required 189 Design, Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable For 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity For Phases & neutral (min. of 250A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. 190 Design, Fabrication, Supplying, Installation, Testing and commissioning of 315A near by control box with 4 pole 315 A MCCB switch with front handleDust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral (min. of 250 A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge 191 Design, Fabrication, Supply, installation, testing and commissioning of 30KVAR Automatic power factor correction panel (APFC) with 6steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment For each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 6 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. capacStart, Stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus For the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., complete 192 Supply, Erection, testing and commisioning of 82.5KVA/66 KW Diesel Generating Set (as per the latest CPCB IV+ norms) comprising of Water Cooled, 4 cylinder Diesel engine developing minimum of 102 BHP with electric start compression ignition 4 stroke designed to run continuously at at 1500 RPM. Coupled to Alternator rated at 1500 rpm, 415 Volts, 0.8 power factor, 50 Hz, three phase supply, self-excited and self-regulated, brushless, floor mounted with ball or bearings on end shields and fuel Tank of minimum 150 Ltrs capacity with Standard Control Panel with Breaker, Batteries and Acoustic Enclosure including Transportation, loading-Unloading, UG cable laying from generator to panel, earth strips connections etc., at the site of work as required (Model should have minimum 2 year warranty) 193 Supply, Installation, Testing and Commissioning of 15kVA DOUBLE CONVERSION 3 phase input,3 phase output True Sinewave ONLINE UPS with 0.99 power factor including stand along with supply and erection of 12V/26AH SMF Batteries (30mis back up) of 30 nos.including providing necessary connections etc. complete as required 194 Supplying, fixing and testing of CO2 fire extinguisher of 4.5 kg capacity with hose and horn confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 195 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 10 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 196 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 6 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 197 Supplying and fixing of MS angle fire bucket stand with 03 Each fire buckets of 10 litre capacity, at the site of work as required. 198 Supplying, installation, testing and commissioning ofsmoke detection system with minimum of 36 Each conventional type photo-electric smoke detectors, 2x1.5 sq.mm fire resistant armoured cable(red colour), 6 Each Manual Call points, 6 Each Hooters complete with 2 zone fire alarm panel etc at site of work as required 199 Supply, Installation, Testing and commissioning of 16 channel 4 SATA NVR, with 4T Hard Disk Drive 1 Each, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface For HDD connection, Support upto 10TB capacity For each HDD, Smart search For efficient playback. and smart playback to improve the playback efficiency, Supports VCA search For fire/ship/temperature /temperature difference detection triggered video files, POS inFormation overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect For easy network management, 2 Gigabit Ethernet network interfaces 200 Supply ,Testing and Commissioning of 4MP Infra Red Dom Camera and fixing the same on wall/ceiling including providing necessary connections etc. complete as required 201 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse 202 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3Each m) USB -3Each n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37) 203 Supply, laying and termination of high quality Un- Armoured Optical Fiber (48 Fibers) along with the all accessories connectors, switches etc complete as required 204 Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer 205 Supply, fixing and termination of high quality floor mounted type 24U floor mountable powder coated Rack with 3x5A Power Manager, 1 position fan, min 1 nos of shelf, Front Glass double door with Lock & key with suitable network port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer in charge 206 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with followingcomponents complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 207 Supply, Erection, Testing and Commissioning of new 160 kVA, 11kV/433V, 3-Phase, 50 Hz, ONAN Cooled, Copper wound Transformer with Energy Efficient level-I, Dyn11 vector group, first fill of oil, Bushing on HT side & Cable box on LT side, off circuit tappings of +5% to -10% in steps of 2.5% with standard fittings confirming to IS 1180, including transportation of the machine from OEM factory to site, mechanized mounting of transformer in the DT structure, providing necessary cable end terminations (LV side), connection of 4 SWG copper down conductor (HV side), body and neutral earth connections, insulation resistance testing and certification of the same etc. as required 208 Providing new service connection to the Divisional Office building by preparation of drawings, coordinating with EB, deposit amount/ statutory charges to be paid to EB for supply and fixing of poles/DT structures, overhead ACSR conductors, associated accessories, including any additional works as per the instruction of EB/FCI engineer-incharge etc. as required. (Deposit Amount/Statutory Fees will be paid by FCI as per actual only) 209 Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conForming to IS: 694in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 210 Supply,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 211 Supply of 2m x 1m x 3mm thick corrugated rubber mat as required conforming to relevant ISI specification suitable for electrical application
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
45.
Public Administrative Department #9493970 Technical Bid
Tender For Place making work from Naja Market Novelty Square to Municipal Corporation office in Hazratganj - DISMANTLING WORK 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 3 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (in cement mortar) 5 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 6 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (BITUMINOUS ROAD) 7 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 8 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 9 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge 10 CIVIL WORK 11 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 12 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. 13 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc for mass concrete 15 Providing & Laying Designer Pavers 100mm x 100mm with thickness ranging from 70-90mm of approved shape and complete as per direction of Engineer-in- Charge. including transport ,loading ,unloading and conveyance of material from available source to work site, including labour charges for fixing and pointing etc., complete 16 Sand FillingFilling in foundation trenches as per drawing and technical specifications clause 305.3.9 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 19 Cement mortar 1:3 (1 cement :3 coarse sand) 20 12 mm cement plaster of mix : 21 1:4 (1 cement: 4 coarse sand) 22 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 23 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 24 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 25 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand): 25mm thick 26 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 27 Supply and installation of 60 L: AUX Waste Bin of material Stainless Style with Contemporary Mounting: Root fixed, Surface/baseplate fixed, wall/post mounted with Features: Ashtray, complete with foundation as per the direction of the Engineer in charge 28 Providing and laying drain gratings on both sides of the road anlong with tree grating wherever required. 29 Drain Grating - FRP GRATING (DRAIN)SIZE: 366 x 1001 x 30 H MMTHICKNESS: 6/7 MM 30 Tree Grating - SIZE: 800 x 800 x 400 (Inner Dia’) MMTHICKNESS: 30 MM 31 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mm 32 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia 34 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications 35 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 36 Centering and shuttering including strutting, propping etc. and removal of form for : Walls 37 Steel in kg 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 39 For vertical surface two coats @ 0.70 kg per sqm per coat 40 For horizontal surface one coat @1.10 kg per sqm. 41 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineerin-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately). 12 mm thick one side Pre-laminated particle board (decorative lamination on oneside and other sides balancing lamination) grade -1, medium density flat pressed,three layer particle board FPT - I or graded wood particle board FPT-1 conformingto IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 andpre-laminated conforming to IS : 12823, Grade -1, Type II marked 42 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia 43 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate 44 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia 45 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness5.40 mm 46 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 47 brick ballast 40 mm class 150 48 brick ballast 40 mm class 150 49 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications including, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge 50 Supply and fixing of Bollard made from mid steel with CNC machine finishingwith 140mm outer diameter , thickness of 3mm r and 1100mm Height . Expose height 900mm from above Ground level and fixed the remaining 200mm below the GL. three number of circular rib of R06mm radius are provided at the top . The whole product is power coated black colour as per standard recommendation of Engineer. For fixing the Bollards with M10 cement concrete footing of minimum dimension 20cmx20cmx20cm,with base plate, anchor rods complete. 51 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 52 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applyingHeat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee Support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge. 53 Mandatory/ Regulatory sign boards of 900 mm diametrewith support length of 3750 mm 54 Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size, PSR 55 Signage-A Informative Signage of Sandstone/Marble of size (1200x2100)MMvisibly from both side, PSR 56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab except colour of Black, Cherry/Ruby Red or equivalent 57 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 58 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 59 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 60 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 61 Supplying, fixing and commissioning of Hydraulic (Retractable) Bollards as per specification 62 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 63 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 64 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 65 Labour rate for the mentioned item. Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundationbolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. 66 Providing & fixing ofConcrete Drain Covers Sandstone Colour550X750X50MM Colour: Sandstone Ultra High Performance Pigmented Concrete With Steel Fiber Reinforcement Load Capacity Suitable for 10 Tonne Pigmented Concrete Bayferrox Lanxess Fe203 Colour Index 77491.0000etc all complete in direction of engineer in charge 67 Providing & fixing of Concrete drain cover Concrete Drain Covers Sandstone Colour 550X750X50MM Ultra High Performance Pigmented Concrete With Steel Fiber Reinforcement Load Capacity Suitable for 40 Tonne Vehicle Passing Bayferrox Lanxess Fe203 Colour Index 77491.0000 etc all complete in direction of engineer in charge 68 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastenersat both ends. The work shall be executed as perdrawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 69 PLUMBING OF AREA- HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT 70 SANITARY FIXTURES & ACCESSORIES 71 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 72 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White 73 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require 74 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 75 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 76 32 mm dia (for wash basin) 77 Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 78 Providing & fixingtoilet paper holder. C.P. Brass 79 WATER SUPPLY PIPES AND FITTINGS 80 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 81 Internal work exposed on wall 82 40mm nominal outer dia pipes 83 50mm nominal outer dia pipes 84 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 85 Concealed work including cutting chase and making good the wall etc. 86 15mm nominal outer dia pipes 87 20mm nominal outer dia pipes 88 25mm nominal outer dia pipes 89 32mm nominal outer dia pipes 90 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 91 40 mm nominal bore 92 50 mm nominal bore 93 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions.45 cm length: 15mm nominal bore 94 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 95 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. 96 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 97 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. 98 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 99 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 100 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 101 150 x 100 mm. size P type 102 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 103 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 104 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 105 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 106 PN - 10 Pipe, 50 mm OD (SDR-11) 107 PN - 10 Pipe, 75 mm OD (SDR-11) 108 PN - 10 Pipe, 110 mm OD (SDR-11) 109 TOTAL ( SCHEDULED ITEM ) 110 PART B(NON SCHEDULED ITEMS - AS PER MARKET RATES) 111 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 112 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) 113 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 114 P-Trap type Floor Trap 110 x 75 mm 115 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 116 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 117 C. INTERNAL ELECTRICAL WORKS -HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT 118 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 119 Group A 120 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required 121 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 122 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 123 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 124 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 125 Supply and drawing co-axal TV cable RG-6 Grade, 07 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PCV sheath in the axisting surface/recessed steel/PVC conduite as required. 126 1 Pair, 0.5mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, Telephone cable 127 Supplying and fixing following Suitable size GI Box with Moudular plate and cover infront on surface or recess, including providing and fixing 2 nos 3 pin 5/6 A moduler socket outlet and 2 nos. 5/6 A moduler switch, connection etc. as required. ( for light pluges to be used in non residentions, painting etc. as required. 128 Supplying and fixing following Suitable size GI Box with Moudular plat and cover infront on surface or recess, including providing and fixing 25 A moduler socket outlet and 25 A moduler SP MCB C Curve including connections, painting etc. as required. 129 Supplying and fixing PVC batten/ angle holder including connections etc as required. 130 Supply and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 131 5/6 A Switch 132 2 way 5/6 A switch 133 Telephone socket outlet 134 TV Antenna socket outlet 135 Bell Push 136 Supplying and fixing following size/ modules, GI box along withmodular base & cover plate for modular switches in recess etc as required. 137 1 or 2 Module (75mmX75mm) 138 3 Module 100mmX75mm) 139 4 Module 125mmX75mm) 140 6 Module 200mmX75mm) 141 8 Module 125mmX125mm) 142 12 Module 200mmX150mm) 143 Supplying and fixing following modular base & cover plate on existing moduler metal boxes etc. as required. 144 1 or 2 Module 145 3 Module 146 4 Module 147 6 Module 148 8 Module 149 12 Module 150 Supplying and fixing of following sizes of pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 151 25mm 152 32mm 153 Supply, installation, testing and commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with brush less direct current (BLDC) Motor, class of insulation: B, 3 nos. Blades 30cm long down rod, 2 nos, canopies shackle kit, safety rope, copper winding, power factor not less than 0.9 service value (CM/M/W) Minimum 6.00, air delivery minimus 210 cm/min 350 rpm (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washer, temperaure rise = 75Degree C (max.), insulation resistance more than 2 mega ohm, Suitable for 230 V, 50Hz single phase AC supply, earthing etc. Complete as required. 154 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as 155 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. asrequired. 156 Supply and fixing call bell/Buzzer suitable for single phase,230V, Complete as required. 157 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 158 Supplying and fixing following way, Horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 159 4 way(4+12) , Double door 160 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 161 16 way , Double door 162 Supply andfixing following rating, double pole, 240 V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 163 40 A 164 Supply andfixing following rating, four pole, 415 V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 165 63 A 166 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 167 Single Pole 168 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 169 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe et 170 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as 171 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 172 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 173 PART B - NON - SCHEDULED ITEMS (AS PER MARKET RATES ) 174 Supply & erection of AC 230/250 volts 50 hz Exhaust fans including provding nut bolts mounting frame and other accessories including connection etc complete as required as per direction of E /I make:- Havells / Cromption / USHA 175 300 mm Sweep 900 RPM 176 Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA 177 Supply & fixing of following Telephone outlet 178 Supply & installation of CCTV / Suvillance system. (Honeywell 20 channel NVR full HD IP based- 01 nos, IP Honeywell dome camera 2MP with night vision- 8 nos., IP Honeywell 2 MP HD Bullet camera with night vision- 8 nos.) 179 Supply of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, including tube on surface complete in all respect. 180 1 X 22 W 181 Supply ofrecess/Surface/Pendent mounting round 12 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. (Make: Wipro) 182 LED Fancy Gate Light, Aluminium, 12 W 183 Earth work in excavation bymechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.All kinds of soil 184 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5kmalso includingrammingandwateringoftheearthinlayersnot exceeding20cmintrenches,plinth,sidesoffoundationetc.complete. 185 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 186 Providingandlayinginpositioncementconcreteofspecified grade excluding the cost of centering and shuttering - All work uptoplinthlevel:1:3:6(1Cement:3coarsesand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 187 Brick work with common burnt clay F.P.S. (non modular) bricks of class -150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 188 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. M-25 Grade Concrete 189 SteelreinforcementforR.C.C.workincludingstraightening, cutting,bending,placinginpositionandbindingallcomplete Thermo-Mechanically Treated bars of grade Fe-500D or more 190 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 191 Providingandapplyingwhitecementbasedputtyofaverage thickness1 mm, of approved brandand manufacturer,over the plasteredwallsurfacetopreparethesurfaceevenandsmooth 192 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm 193 ProvidingandlayingfactorymadechamferededgeCement Concretepaverblocksin footpath, parks,lawns, driveways or light trafficparking etc,of requiredstrength, thickness& size/ shape, made by table vibratory method using PU mould, laid in requiredcolour&patternover50mmthickcompactedbedof sand, compacting and proper embedding/laying of inter locking paverblocksintothesandbeddinglayerthroughvibratory compactionby usingplatevibrator,fillingthe jointswithsand andcuttingofpaverblocksasperrequiredsizeandpattern, finishing and sweeping extra sand. complete all as per directionof Engineer-in-Charge. 194 60mm thick cement concrete paver block of M-35 gradewith approved colour, design & pattern (Square and Rectangular shape) 195 80mmthickC.C.paverblockofM-35gradewithapproved color design and pattern.(Square and Rectangular shape) 196 Providing and laying matt finished vitrified tile of size 100x100x16mmhavingwaterabsorptionlessthan0.5%and conformingtoIS:15622ofapprovedmakeinallcoloursand shadesinoutdoorfloorssuchasfootpath,courtyardmulti modelsetc.,laidon20mmthickbaseofcementmortar1:4 (1cement:4coarsesand)inallshapes&patternsincluding groutingthejointswithwhitecementmixedwithmatching pigments etc. complete as direction of Engineer-in-Charge. 197 Providingandlayinginpositonreadymixedorsitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate and aggregate derived from natural sources,PortlandPozzolana/OrdinaryPortland/PortlandSlag cement,admixtures in recommended proportons as per IS:9103 to accelerate / retard sieving of concrete, to improve durability and workabilitywithoutimpairingstrength;includingpumpingof concretetositeoflaying,curing,carriageforallleads;but excludingthecostofcentering,shufering,fnishing andreinforcementasperdirectonoftheengineer-in-charge;for the following grades of concrete.Note: Extra cement up to 10% of the minimumspecified cement content in design mix shall be payableseparately.Incasethecementcontentindesignmix ismore than 110% of the specified minimum cementcontent, the contractor shall have discreton to eitherre-design the mix or bear the costofextracementConcreteofM25gradewithminimum cement contentof 330 kg /cumOne CubicMetreConcrete of M30 grade with minimum cement contentof 350 kg /cumOne CubicMetreConcrete of M35 grade with minimum cement contentof370kg/cumOneCubicMetreConcreteofM40grade with minimum cement contentof 390 kg /cumOne CubicMetreConcrete of M50 198 Concrete of M30 grade with minimum cement contentof 350 kg 199 Applying stamping finsh of the top surface of freshlylaid plain / reinforced cement concrete of specifedgrade in portco, side walks, drive ways, pool decks andopen yard as per directon of the Engineer-in-Charge.* The concrete shall be placed and screened to thefnished grade and •oated to the uniform surface byusing standard fnishing techniques. approved colorhardener @2.7 kg/sqm shall be applied evenly to thesurface of the fresh concrete by the dry shake methodby sprinkling in twoor more shakes foated aer eachshake and trowel only after final coating. The approved released agent @ 0.113 Kg/Sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the fexiblepolyurethene stamp moulds of approved design and inrequired sizes to achieve fnal stamping pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufcient size and weight to leave properstamp marks and the process repeated for the remaining concrete surface till the whole surface to bestamped is completed within the time while the concrete is in plastic stage of setting.After stamping, the curing shall be done as permanufacturers specifcatons. After inital curing theimprinted joints shall be grouted using cement slurrymixed with color hardener as per the requirement. Thesurface shall be sealed by applying acrylic based sealernot less than 0.167 litre/Sqm on fnished surf The constructon joints shall be provided by grovecutting of size 4 mm x 20 mm in panel size 3 m x 3 m orlesser as per the site conditons and flling the samewith 10 mm baker rod and providing & laying (PU)Polyurethane based joint sealer of approved make asper manufacturer’s specifcatons and fnished byapplying polyurethene resin based topprotectve clearcoat of minimum 80 micron applied with rollers onproperly cured and dry clean surface. (The cost ofconcrete for flooring is not included in the item, whichshall be paid for seperately).One SquareMetreSupplying and laying of Uni-Axial Woven PolysterGeogrid conforming to MORTH 3100 and IRC113, as soilreinforcement/basal reinforcement includingaccessories like te-strips, nuts & bolts and loops/lugsfor joining reinforcing elements with the facia pannels,overlaps and other protectve elements for synthetcgeo-grids and all other actvites required for reinforcedsoil walls, slopes etc complete as per designrequirements, manufacturer specifcatons and as perdirecton of engineer-in- charge.Uni Axial Woven polyster geogrid of minimum tensilestrength 40KN/m in the Longitudinal directon and 20KN/m in the Transverse directon.One SquareMetre 200 62mmthickcementconcreteflooringwithconcretehardener topping,underlayer50mmthickcementconcrete1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)andtoplayer12mmthickcementhardenerconsistingof mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 201 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 202 Supplying & Laying of Precast Saucer Drain 150 thick 300 mm wideinluding sand bed etc all complete in direction of engineer in charge 203 Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 204 Providing, laying and making kerbchannel 30cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the topsmoothetc.completeandasperdirectionofEngineer-in- 205 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and fillingwith150mmthickjamunasand,includingspreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. 206 Providing andfixing10x10x10cmGranitestoneblockhandcut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mmwidefilledwithsamemortarincludingruledpointingetc. complete as per direction of engineer-in-charge. 207 Providing and laying Polished Granite stone flooring in required design and patterns,inlinearas wellas curvilinearportionsof the building all complete as per the architectural drawings with 18mmthickstoneslabover20mm(average)thickbaseof cementmortar1:4(1cement:4coarsesand)laidandjointed with cement slurry and pointing with white cement slurry admixedwithpigmentofmatchingshadeincludingrubbing, curingandpolishingetc. all completeas specified andas directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 208 ProvidingandlayingflamedfinishGranitestoneflooringin requireddesignandpatterns,inlinearaswellascurvilinear portionsofthebuildingallcompleteasperthearchitectural drawingswith18mmthickstoneslabover20mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith cementslurry and pointing withwhite cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirectedbytheEngineer-in-Charge:Flamedfinishgranite stoneslabJetBlack,CherryRed,EliteBrown,CatEyeor equivalent 209 Painting runway/taxi track/apron marking with adequatenos of coats to give uniform finish with road marking paint of superior makeasapprovedbytheEngineer-in-charge,i/ccleaningthe surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats) 210 Layingoldcementcocreteinterlockingpaverblocksofany design/shapelaidin requiredline,level,curvature,colourand pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocksshall be supplied by the department free of cost). 211 Layingatorneargroundleveloldkerbstonesofalltypesin positiontotherequiredline,levelandcurvature,jointedwith cement mortar 1:3 (1 cement : 3 coarse sand), including making jointswithorwithoutgrooves(thicknessofjoints,exceptat sharpcurve,shallnotbemorethan5mm),includingmaking drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shallbemeasuredforpayment).(Oldkerbstonesshallbe supplied by the department free of cost) 212 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastenersat both ends. The work shall be executed as perdrawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 213 Centeringandshutteringincludingstrutting,proppingetc.andremoval of form for 214 Walls(anythickness)includingattachedpilasters,butteresses,plinth and string courses etc. 215 Providing&fixingofcementconcreteBollardsM-30GradeR.C.C.150mmdiaincludinggoutinginfoundation750mm height including all necessary T&P etc all complete in directio of 216 Repairing of Existing Canopy including PPGL Sheet & necessarymember &Screw,nut, bolts,washer ,including paintingpolishingetcallcompleteindirectionofengineerin charge. 217 Boring/drillingborewellofrequireddia for casing/ strainer pipe, by suitable methodprescribedinIS:2800(partI), including collecting samples from different strata, preparing and submitting stratachart/borelog,includinghire& running charges of all equipments, tools, plants&machineriesrequiredforthe job, all complete as per direction of Engineer-in-charge,upto90metredepth below ground level. 218 300 mm dia 219 Supplying, assembling, lowering and fixinginverticalpositioninborewell, unplasticizedPVCmediumwellcasing (CM) pipe of required dia, conforming to IS:12818,includingrequiredhireand labourcharges,fittings&accessories etc.allcomplete,foralldepths,asper direction of Engineer -in-charge. 220 150 mm nominal size dia 221 Supplying, assembling, lowering and fixinginverticalpositioninborewell unplasticizedPVCmediumwellscreen (RMS) pipes with ribs, conforming to IS: 12818, includinghire & labour charges, fittings&accessoriesetc.allcomplete, for all depths, as per direction ofEngineer-in-charge. 222 150 mm nominal size dia 223 Gravelpackingintubewellconstruction inaccordancewithIS:4097,including providing gravel fine/ medium/ coarse, in requiredgrading&sizesasperactual requirement,allcompleteasper direction of Engineer-in-charge. 224 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) 225 withrequiredcapacityaircompressor, running the compressor for required timetill wellis fullydeveloped, measuringyieldofwellby“V”notch methodorany otherapprovedmethod, measuring static level & draw down etc. bystepdrawdownmethod,collecting water samples & getting tested in approvedlaboratory,i/cdisinfectionof tubewell,allcomplete,includinghire& labourchargesofaircompressor,tools & accessories etc., all as per requirement and direction of Engineer-incharge. 226 Providingandfixingsuitablesize threadedmildsteelcaporspotwelded platetothetopofborewellhousing/ casing pipe, removable as per requirement, all complete for borewell of 227 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm 228 ProvidingandfixingBailplug/Bottom plug of required dia to the bottom of pipe assemblyoftubewellasperIS:2800 (part I). 150 mm dia. 229 Supplyofsubmersiblepumpofmake KSB / Crompton / kirloskar 7.5HP with control panel, support wire etc. 230 Supply and laying of aluminium conductorPVCinsulatedarmoured served sheathed cables 1100 Volts grade ata depth of 750 mm below groundleveloveracushionof75mm. thick sand all around and protectedwithburntbricksonsidesandontop. Onsurfacethecablerunshallbe fixed onM.S.clampsetc.ofsuitablesizeor asdirectedbytheEngineer-Incharge, complete in allrespect. The armouring of the cable shallbeproperly connectedwiththe earthonductor by clamps etc.submersibble cable from pump panel to 231 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. 32 mm dia nominal bore 232 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 233 Supply of 100mm dia Johnson screen. 234 Providing and stacking of Nyctanthes arbor- tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer- 235 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 236 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of 237 Providing and stacking of Ficus panda of height 90-105cm.with10-12branchesandhealthy foliage,wellformedincementpotsofsize30 cm as per direction of the officer-in-charge.. 238 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer- 239 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 240 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 241 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size ofPoly bags & as per direction of the officer-in- 242 Providing and stacking of Asparagus sprengeri of height 15 cm to 20 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 243 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 244 Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer- 245 Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed withrivetscompleteinallrespectsincluding painting inside and outside of tree guard with: Two or more coats of synthetic enamel paint of approved quality shade over a priming coat 246 Trenching in ordinary soil up to required depth includingremovalandstackingofserviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clodsetc.andmakingthetrenchedareawith designedmounds,pathsandsittingspacesetc. toproperlevelsbyfillingwithearthorearth mixed with manure and properly watering completeworkinrequiredtopographyasperdrawing & specifications. 247 Supplyingandstackingofgoodearthatsite includingroyaltybutincludingcarriage 20 km (earthmeasusredinstackswillbereducedby 248 Supplyingandstackingatsitedumpmanure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 249 Mixing earth and manure in specified proportion or as directed. 250 Roughdressingthetrenchedgroundincluding breaking the clods. 251 Fine dressing the ground 252 Spreadingof mixedgoodearthandmanurein specifiedproportionsasaboveandinrequired thickness. 253 Providing&layingSelectionno.1grassturf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothenandlightwateringthesame,asperdirection of officer in charge 254 Preparation of mounds of various size and shape by available excavated / supplied earth in layers notexceeding20cmindepth,breakingclods, wateringofeachlayer,dressing etc.,leadupto 50meterandliftupto1.5mcompleteasper direction of Officer-in-charge. 255 Excavating,supplying andfilling oflocal earth (including royalty) by mechanical transport upto a lead of 5km alsoincluding rammingand watering of the earth in layers not exceeding 20 cm in trenches, plinth, 256 Providing & Laying reinforced cement concrete pipe NP3 for Planter 600mm height and 300 mm depth in ground including excavation, protection work, backfilling, concrete and masonary works all complete in direction of engineer in charge. 257 Fabrication , supply and installation of Stainless steel 304 grade canopy around the existing tree guard with laser cut SS -304 grade fins with satin finish and 10mm thick polycarbonate multiwall sheet on roof from sabic plastic products or equivalent complete in all respect along with it aluminum fittings . SS-304 grade tree grate with laser cut design cutout patterns for waterpenetration will be fixed at the center and 18mm thick gang saw cut mirror polished granite/wood plastic composite wooden planks will be fixed ontop of the existing masionary in a curve shape 258 Cement Concrete Planter 259 D & E .( HORTICULTURE AND EXTERNAL ELECTRICAL WORK)-HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT BILL OF QUANTITY 260 Part G (Horticulture Work) 261 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 262 Supplying and stacking of good earth at site including royalty and carriage upto 20 km lead complete (earth measured in stacks will be reduced by 20% for payment). Analysed Rate. 263 Extra For levelling and neatly dressing of disposed soil completely as per the engineer in charge DSR2023; 2.36 264 Supply and laying of bi axial extruded high modulus polypropylene geo grid conforming to MORTH specifications for base/sub base reinforcement having minimum tensile strength 40 Kn.m IN THE LONGITUDNAL AND TRANSEVERSE DIRESTION, WITH 14 Kn/ M AND 28 Kn/M AND 28 Kn/M TENSILE STRENTGH at 2% and 5 % strain respectively in the longitudnal and transverse direstion, junction eficiency not less than 95% and with 38 mmx 38 mm mesh opening psrLDA Approved 265 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).DSR Horticulture 2020; 2.25 266 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 267 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).DSR Horticulture 2020; 2.8 268 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, byspreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).DSR Horticulture 2020; 2.1 269 Rough dressing the trenched ground including breaking clods.DSR Horticulture 2020; 2.6 270 Fine dressing of the ground., DSR Horticulture 2020; 2.7 271 Providing & laying Selection no. 1 doob grass turf with earth 50mm to60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge DSR Horticulture 2020; 2.34 272 Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately): In rows 5 cm apart in both directions DSR Horticulture 2020/ 2.10.1 273 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 60 cm dia, and 60 cm deep. DSR Horticulture 2020; 2.14.4 274 Holes 45 cm dia, and 45 cm deep., DSR Horticulture 2020; 2.14.5 275 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal ofunserveiceable material’s as per direction of officer in charge (excludingcast of plant & water). DSR Horticulture 2020; 2.57 276 Trees Plant, 2.57.1 277 Shrubs Plant, 2.57.2 278 Hedge Plant, 2.57.3 279 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge., DSR Horticulture 2020; 6.7 280 Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge., DSR Horticulture 2020; 5.3 281 Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge., DSR Horticulture 2020; 8.30 282 Providing and stacking Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. DSR Horticulture 2020; 9.8 283 Providing and stacking of Belamcanda chinensis of height 45-60 cm. branched in earthen pots of size 20 cm as per direction of the officer-in-charge. (Lepord lily), PSR LALBATTI 284 Providing and Displaying of Spathiphyllum (peace lily), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cmof Earthen pot/plastic pot as per direction of officer-in-charge. DSR Horticulture 2020; 3.90 285 Providing and stacking of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliagein Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge., DSR Horticulture 2020; 6.25 286 Shrubs/TREE Plant 287 Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.(DAR 2020 Hort - 8.32) based 288 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12branches and healthy foliage, well formed in cement pots of size 30 cm asper direction of the officer-in-charge. (DAR 2020 Hort - 8.28) based 289 Trees Plant 290 Providing and stacking of Jacaranda mimosifolia of height 10-12 feetin big poly bags of size 18 as per direction of the officer-in-charge.PSR 291 Providing and stacking of Butea frondosa (Flame of Forest) healthy and multi branches of height 4-6 feet in big poly bags of size 18 as per direction of the officer-in-charge.PSR 292 Providing and stacking of Lagerstroemia Flaush (jarool) healthy and multi branches of ht.10-12 feet in Earthen pots of size 12 as per direction of the officer-in-charge. PSR 293 Providing and stacking of Tabebiua (Dolne smith) healthy and multi branches of ht.12-14 feet in Earthen pots of size 18 as per direction of the officer-in-charge. PSR 294 Providing and stacking of Terminalia Mentali healthy and multi branches of height 10-12. in big polybags of size 18 as per direction of the officer-in-charge. PSR 295 Providing and stacking of Plumeria alba healthy and multi branches of height 10-12 feet in big poly bags of size 18 as per direction of the officer-in-charge.PSR 296 Providing and stacking Nicodia of height6-8 feet with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.PSR 297 Providing and stacking Cassia Gluca of height 8-10 feetwith bushy healthy plant in 14 bags & as per direction of the officer-in-charge. PSR 298 Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.PSR 299 Supply and installation ofBamboo of Height 10-12 feet. In all work complete. Market RatePSR 300 (Irrigation) 301 Trenching and Back Filling. Sanctioned Rate. 302 Supply, Installation, laying & commissioning of 90 mm outer dia 6Kg/cm2 HDPE pipe. 33.01 (Jal Nigam Varanasi SOR) 303 Supply, Installation, laying & commissioning of 63 mm outer dia 6Kg/cm2 HDPE pipe. 33.01 (Jal Nigam Varanasi SOR) 304 Supply, Installation, laying & commissioning of HDPE Flange with tail piece, packing & nut bolt complete in all respect. Sanctioned rate 305 Supply, Installation, laying & commissioning Of reducer 90 mm to 63 mm outer dia 6Kg/cm2 HDPE pipe. Sanctioned rate 306 Supply, Installation, laying & commissioning Of ELBOW JOINT 90 DEGREE FOR 90 mm HDPE pipe. Sanctioned rate 307 Supply, Installation, laying & commissioning Of ELBOW JOINT 90 DEGREE FOR 63 mm HDPE pipe. Sanctioned rate 308 Supply, Installation, laying & commissioning Of TEE JOINT90 DEGREE FOR 90 mm HDPE pipe. Sanctioned rate 309 Supply, Installation, laying & commissioning Of TEE JOINT90 DEGREE FOR 63 mm HDPE pipe. Sanctioned rate 310 Supply, Installation, laying & commissioning Offor 63 mm TAIL PIECES. Market Rate 311 Supply, Installation, laying & commissioning of for 90 mm TAIL PIECES HDPE PIPES. Market Rate 312 Supply, Installation, laying & commissioning Of PRESSURE Gauge 2.5 size (Gyceryne). Market Rate 313 3 disc filter. Market Rate 314 2 disc filter. Market Rate 315 Thermos Temperature Controller wuth switch and socket .2 mm cable. Market Rate 316 Butt velding electric heating plate. Market Rate 317 3 CIbutterfly valve. Market Rate 318 2 CIbutterfly valve. Market Rate 319 SPRINKLERS 320 Supply, Installation, laying & commissioning of Service Saddle 3 inch x 1.25 inch. Sanctioned rate with bush 321 Supply, Installation, laying & commissioning of Service Saddle 2 inch x 1.25 inch. Sanctioned rate with bush 322 Supply, Installation, laying & commissioning of Swing Joint for 10 - 12 meter range 360 degree popup. Market Rate 323 Supply, Installation, laying & commissioning of Swing Joint for 3 - 4 meter range 360 degree popup. Market Rate 324 Supply, Installation, laying & commissioning of 25 mm outer dia 6Kg/cm2 CPVC pipe. Market Rate 325 Supply, Installation, laying & commissioning Of Ball Valve for 25 mm pipes. Market Rate 326 Supply, Installation & commissioning of pop sprinkler plastic make material with 3 - 4 meter range 360 degreesMR 327 Supply, Installation & commissioning of pop sprinkler plastic make material with 10- 12meter range 360 degrees. Market Rate 328 Engagement of Plumber for required work etc all complete as per direction of Engineer in charge. PWD SOR 2020-21/Labour Rates Chapter.Rs. 420.00+10%CP 329 Engagement of Labour for required work etc all complete as per direction of Engineer in charge. PWD SOR 2020-21/Labour Rates Chapter.Rs. 335.00+10%CP 330 4 - BORING 331 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate 332 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.3.3 333 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.10.3 334 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 335 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for bore well of: 200 mm dia. DAR No. 23.13.3 336 Providing & Fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS 2800 part - 1 including necessary bolts & nuts of required size complete. 200 mm clamp. DAR No. 23.14.3 337 Supply and fixing of pump set & composite electric panel for submersible kirloskar/ sons/ crompton openwell pumpset greeves make three phases 380-440 v 50 cycles supply with fountain bolts and 3 core 2.5 mm flat PVC flexible copper conductor double insulated submersible cable and 4 core 1.5 mm form fountain pool to fountain electric panel etc fountain pool to fountain electric panel etc. complete with internal wiring lighting system. 338 7.5 HP pump 339 Electric Panel Box 340 Supply and fixing of 3 HP single phase open well submersible pump set of 50 mm x 50 mm pipe size complete with all material, labour T&P etc all as per direction of Engineer in charge. (make kirloskar/ crompton/ KSB 341 Supply and fixing of 2.5 sqmm 3 core PVC insulated PVC shethed flate submersible cable pump with bare bunched copper conductor for submersible pump motor with 1100 volt grade ISI marked all complete as per direction of Engineer in charge.Sanctioned Rate 342 Arrangement of Plumber for 1 year maintenance. PWD SOR 2020-21 343 Horticulture Maintenance 24 months 344 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide will be provided by the Department & lawn mover and brush cutter with fuel , other T & P material/articles shall be provided by the contractor.) Play grounds / Public parks Per Sqm (as per yard stick 1Mali =2.00Acre).DSR (Hort) 2020/2.40.5 345 Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/ edge bed watering, manureing & apply insecticides & fungicides etc. (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.DSR20202.2.36 346 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 05 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment). DSR 2020 horti - 2.25 347 Supplying and stacking of good earth at site including royalty and carriage upto 15 km complete (earth measured in stacks will be reduced by 20% for payment). Analysed Rate. 348 Supply & stacking Urea 40% Nitrogen @160 kg per acre (as per yard stick of CPWD LDA SOR 2018-19/11.1 349 Supply & stacking DAP 50 kg per acre/year. LDA SOR 2018-19/11.2 350 Supply & Stacking Bone Meal/ Oil Cake(LDA SOR Horti 2018-19/11.3) 50 kg per acre/Year 351 Removal of garden waste by TATA 407 or equivalent including loading and unloading and carriage upto 1 km lead, complete disposal upto designated place as per direction of Officer in charge. DSR Horticulture 2020/2.60 based (Analysis Rate attached) 352 Part H (Electrical) 353 PART (X) 354 FOUNTAIN 355 SITC of Spray comprises of a Calyx Aerating in center flanked with Foam Jets on 4 corners of waterbody.Manifold/Pipework are made from Galvanised steel, B-class, make Jindal, ISI Mark with necessary accessories like flanges, sockets, stands etc. made of steel- galvanized. High quality rubber gaskets, nuts & bolts along with gunmetal control valves to adjust flow pressure.Proper completion of workAs per direction of E/IcFOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 356 SITC of In Calyx Aerating Spray, water is sprayed in an inverted cone pattern withasmallcenterjet.Calyxnozzlemadeofaluminiumalloy– epoxycoated/StainlessSteel,centerjetnozzlemadeofbrass– chromeplated.Approx.heightofwatereffects:Calyx–1.25m heightX4.5mdia,CenterJet–3mheight. Proper completion of workAs per direction of E/Ic,FOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 357 SITC of Foam jet nozzle, on ball joint, of1.25” orifice size. Nozzle made ofBrass- Chrome plated. Approx. height of water effects: 1.2m. Proper completion of workAs per direction of E/Ic, FOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 358 Supply,Installation,TestingandCommissioningofLuminaries comprise of 12V LED lights (RGB). Complete light body made of Stainless steel 304 grade, total 27watt power leds. Toughened glass with seal.Stainless steel 304 grade cable gland. All external nuts and bolts are of Stainless steel 304 grade. Adjustable mounting bracket is made of Stainless steel 304 grade. IP 68 compliant. All in pool connections shall be fully waterproof. Make of Luminaries As per direction of E/Ic,FOR A 6 METER DIA WATERBODYPSR 359 SITCofMonoblocktypesubmersiblepumpset whit stainer/ filter ofFollowing Capacity(Threephase,50Hz,415-380VAC)propercompletion ofworkasperdirectionofE/Ic. Kirloskar/Crompton Greaves/KSB/Texmo. Suction filter for pump: Filter body & filter mesh made from AISI 304 standard stainless steel. As per direction of E/Ic 360 3 HP PSR 361 SITC of 1.1 kV grade double insulated copper flexible cable 2.5 sq.mm x 3 core for pumps,As per direction of E/IcPSR 362 SITC of 1.1 kV grade double insulated copper flexible cable 1.5 sq.mm x 4 core for lights, As per direction of E/Ic PSR 363 PSR Supply, Installation, Testing and commissioning of specialised Outdoor type Electric panel for fountain which include control arrangement for fountain, pumpset andRGB Sequencing lighting comprises of :1. Contactor 25 Amp- 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)2. DOL Starter - 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)3. Single Phase Preventer- 01 Nos (Make: Bentex/ Selec/ GIC or equivalent)4. Incomer Main Switch 20 Amp- 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)5. Overload Relay 6-12 Amp- 01 Nos (Make: L&T/ Schneider/ ABB/ BCH or equivalent)6. Fuse for motor 32 Amp- 03 Nos (Make: GE/ L&T or equivalent)7. MCB for Lights 6 Amp -01 Nos (Plaza/ Anchor/ ABB/ Havells/ Legrand or equivalent)8. Push Button On/ Off switches (Red/ Green)- 02 Nos. 9. Overload Indicator - 01 Nos (Make: Eaton/ Siemen or equivalent)10. Single Phase Indicator- 01 Nos (Make: Eaton/ Siemen or equivalent)11. 3 Phase indicator RGB- 01 Nos (Make: Eaton/ Siemen or equivalent)12.Voltmeter- 01 Nos. (Make: Motwane, Innova, Fluke or equivalent)13. Ampere Meter- 01 Nos (Make: Motwane, Innova, Fluke or equivalent)14. SMPS/ Transformer for lights- 01 Nos (Make: Meanwell/ Pheonix/ Omron or equivalent)15. RGB Lights controller- 01 Nos. (Make: Wet Design/Fontana/A.M. Irrigation System/Bharat engineers)16. Internal Wiringsteel sheet 16 gauge paint finish enclosure with hinged front door with provision for incoming & outgoing cable entry. Outgoing ampere 10, size of panel - 3ft X 2ft X 1ft depth.As per direction of E/Ic PSR (36/G20/CE/23) 364 Supply of 4000mm Extruded Square aluminum pole (grade 6063) Sq. 150 x 3mm thickness with IP68 Connector.Bespoke laser cutting design of length 1400mm with 50W In-Built LED with controlled downward light emission options (customized) with SS fasteners, Pre treated epdm black gaskets. Die-cast aluminum mounting plate Sq.250 x 12mm thick with 4 elongated holes 38 x 19 to suit M16 bolts at PCD 180 with pure polyester powder coating. Fixed with Hot dip galvanized foundation bolt. Mechanical resistance should be minimum IK06. The Pole should be undergone pure polyester powder coating process & Acid treatment to ensure high corrosion resistance. On the top of the pole there will be built-in Spot Lights of 2 x 18W LED are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Inbuilt Surge protection 6KV. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Colour Temperature LED 3000K, 230-240Vac, CRI >80, MacAdam step 3. The driver should be inbuilt in the pole itself and maintenance can be done from the junction box itself. PDC aluminum service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable,6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Any other internal cables and connections shall not be covered in the scope of supply. The manufacturer should have Inhouse NABL accredited lab to check and provide correct photometry of the product. The make should be as per K-Lite Verbena Spot KL-4583/Wipro/Ligman 365 Supply and fixing of 3500mmsteel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . POLES BPTH SIDE OF THE ROADS AT 10 METER CC DISTANCE. PSR - BEGUM HAZRAT MAHAL PARK 366 Supply and fixing of OVER 600mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore, K LITEor equivalent repuateted make Quotation rates 367 S/E of G.I. wire on 8 to 4 SWG on pole/service bracket including binding etc. complete in all respects SI.No. 628/18. 368 S/W of submain with two Nos. of 2.5 Sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material Labour and T&P required for proper completion of the work as directed at site by E/I. SI. No. 289/18. 369 S/Fof40ATPNofAutomaticstreetlightcubiclecontrolpanelpaintedwithanti corrosivealkaliandacidproofpaintconsistingoftimeswitchTSO100serieswith contractors,HRCfuses,isolatingswitchmeteringinstrument& instrumentbox with CTs etc, in case of TPN, complete in all respect as per direction of Engineer-in-charge. SI. No. 807/18 e(ii). 370 S/L of following cable Al conductor P.V.C. insulated armoured served sheathed cable 1100V grade at a depth of 750mm. Below ground level over a cushion of 75mm with DWC Pipeapproved makeUPPPCL as per direction of E/I. complete in all respects. 501/2018. Approved Makes:- Gloster/ Polycab/ KEI/ SCI/ Havells PWD SOR 501 371 10 sq. mm 4 core 372 (a) 35 Sq.mm 3.5Core 373 (b) 16 Sq.mm 4 Core 374 (c) 70 Sq.mm 3.5 core 375 S/F of following size palm or pin type copper tin plated cable socket (Lug) to the cable leadinsulatingwithtapeandmakingconnectionscompleteinallrespectsasper direction of E/I.SI.No.504/SOR-18. 376 10 sq. mm 4 core 377 (a) 25 sq.mm. 378 (b) 50 sq.mm 379 (c) 16 sq.mm 380 S/B of earth rod 20mm dia into 2.5mtr long including G.I. wire 7/16 SWG to connect earth rod to earth clamp on pole 3.00 mtr long steel conduit to carry earth wire along the pole. A.R. Bond No.87/CE/EE(E/M)2021, Dated 09-11-2021 381 S/Fof6Ampto32Amp.SPMCB(10KA)Ccurvecompleteinallrespectasper direction of Engineer-in-charge. SI No. 1002/18. CAT-A. 382 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountendon non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. ( Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TNP-2 Nos. Cat. B. Cubicle TypePWD SI No : 802 (a) 383 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PWD SI No :725 (A) 384 Supply and Laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. DSR E&M 2022/14.161 385 Supply, Installation, testing & commissioning of Servo Stabilizerwith Isolation transformer 100KVA,3-phase servo voltage stabilizer with isolation transformer , oil cooled, Input 300-470 VAC, 4 Wire, 50 Hz, output: 400+/-1% with oil,suitable for UNBALANCED LOAD with automatic operation (outdoor type-IP 64).The stabilizer shall comply with the following requirement:: Regulation : +/- 10 %.: Over load & Short circuit protection.: Protection cut-off against Over/Under Voltage.: Single phase protection.: 3 nos. phase indication lamps. 386 PLINTH AREA RATES CPWD 2023, Supply installation , testing and commissioning of IP based CCTV system for building security comprising of PTZ/FIXED CAMERA, CABLING , RECORDING , DISPLAY SYSTEM HARDWARE SOFTWARE SUPPORT,FOR EXTERNAL SURVILLANCE 6.10.2 , FOR PLAZA AREA ONLY 387 Operation and maintenance for 1 years 388 PART (Y) 389 LFkkfir dh x;h ykbZVksa ds vuqj{k.k ,oa lapkyu dk dk;ZA 390 Providing of Trained Electricion With Tool Kit (As per PWD SOR/2020-202. For 18 months after DLP 391 Providing ofHelper Technicion (As per PWD SOR/2020-2021.For 18 months after DLP 392 PART-Z 393 H.T./L.T. work 394 S/Fofdoublepolestructurewith2nosS.T.poleforS/S 410SP-55 11 Mtr. longin1:3:6CC foundation 1/6 of pole length below G.I. and 30cm above G.I. 20cm thick around the pole with 2 nos. channel 125mmx75 mm one No. Chennel cross arm of 75mmX 40mm 2 No. 50X50X6mm sngle iron bracings with necessary nut bolts & packing pieces complete with painting as per direction of E/I.(PSR Bond No. 490/CE/2024) 395 S/F of 11 KV Pin insulator with G.I. Bolt /spindle nut etc. complete in all respects. (PSR Bond No. 490/CE/2024) 396 S/Fof11KVDiscinsulatorincludinggunfittingoncrossarm/clampsfixedonpole complete in all respects. (PSR Bond No. 490/CE/2024) 397 S/E of over head line with A.C.S.R. conductor on pole/service bracket including binding etc. complete in all respects. S.I.No-627/18. Racoon/Dog(PSR Bond No. 490/CE/2024) 398 S/F of M.S. Channel 75mmX40mm Vshape crossd arm for two No. pin insulator proper completion of work. (PSR Bond No. 490/CE/2024) 399 S/E of 11 K.V L.A. set of 3 wire. suitable for mounting on steel support complete in all respect as perdirection of E/I.(PSR Bond No. 490/CE/2024) 400 S/Eof11K.V.T.P.M.O.switchonpoleincludinghandlerodetc.completeinall respects as per direction of E/Ich.(PSR Bond No. 490/CE/2024) 401 S/E of 11 K.V. D.O. fuse set on pole complete in all respect as per direction of E/I.(PSR Bond No. 490/CE/2024) 402 Supply and laying of70 Sqmm 3 core 11 KV standered aluminium conductor XLPE(Cross linked polyethylene)insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connectedwith earth conductor by clamps etc. PWD SOR No : 506 (d) (PSR Bond No. 490/CE/2024) 403 S/F of 70 Sq.mm size 3 core XLPE 11 KV outdoor type jointing kitproper completion of work as per direction of E/I A.R. Make: Raycheme, Mahindra. (PSR Bond No. 490/CE/2024) 404 S/F of level 2 following capacity 11/0.433 K.V. Al’ wound conventional 50Hz 3 phase oil immersed naturally cooled distribution T/F confirming and with amendments there of, havinglosses as per BEE standered with all standard fittings, including first filling of oil complete in all respects, of make UPPCL/KESCO Approved (PSR Bond No. 490/CE/2024)(a) 63 KVA (A.R.) 405 Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra)Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.S.I.No-726 B/18. 406 S/Lof25mmx3mmGIstripfromearthelectrodedirectlyinthegroundasrequired complete in all respect Item No 716 SOR-2018 407 Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion ofwork. PWD SI No : 1142 408 S/L of followingsize G.I.B classpipe ata depthof 750mmbelow groundlevel as cable carrier as direction of E/Inch. (PSR Bond - 490/CE/2024)(a) 80 mm dia
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Uttar Pradesh View Result →
46.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
47.
Housing Urban and Rular Development #9468305 Technical Bid
Tender For Rates For Material/Equipment Regarding Medical Gas Pile Line System And Modular Operation Theatre For Estimate Preparation. - Rates for Material/Equipmentregarding Medical Gas Pile Line System and Modular Operation Theatre for estimate preparation. 2 Medical Gas Pipe Line (Part-A) 3 Oxygen Manifold 4 SITC of 10 + 10 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. as per specification (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 5 Certifications: ISO 13485:2016,ISO 9001:2015, CE 6 Fully Automatic Oxygen Gas Control System 7 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 8 Oxygen Flowmeter with Humidifier 9 Essentia medical gas flowmeters are designed to measure and regulate flow.These are calibrated to specific gas & flow range. Oxygen flowmeter is intended for use with various delivery system when bubble/ micro bubble humidifier is attached downstream. These flowmeters are widely used in home care, health centers, district/ general/ regional hospitals, tertiary care, emergency vehicles etc. for administration of supplemental oxygen through nasal cannula, simple face mask,partial rebreathing mask, non re-breather mask, resuscitation mask etc. A passive process to humidify dry therapeutic gas (Category 3 Humidification) Micro Bubble Humidifier for Respiratory Therapy Patient connection port : Tapered hose barb suitable for 6 mm inner diameter plastic tubingMicro bubbles through humidifier for efficient humidificationPossible to integrate into an oxygen concentrator, sleep apnoea therapy equipmentOptimal RH achievable at various flow settingsAutoclavable at 121°C (249.8°F) for 5 minutes (Minimum 5 autoclave cycles)Over pressure safety valveNon-heated and reusableInlet connection port : DISS female adapter with chrome plated Brass nut embedded in ABS for hand-tighteningFlow : Up to 15 lpm @ 4 bar (58 psi)Construction material: Polycarbonate - shatter resistantCapacity - 240ml at max water level (Jar 450ml)Make- Altos/Aktiv or Equivalent 10 Emergency Oxygen Manifold 11 The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 6 cylinders in each Bank (means 6+6) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Make- Altos/Aktivor Equivalent 12 Fully Automatic Oxygen Gas Control System 13 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 14 MEDICAL NITROUS OXIDE SYSTEM 15 Nitrous Oxide Manifold 16 SITC of 4 + 4 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders.. as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 17 Fully Automatic Nitrous Oxide Gas Control System 18 SITC of Fully Automatic Control Panel for Nitrous Oxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel. It should fully complies and meets with the requirements of the NFPA-99 standards. It should be UL or ETL Listed. The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 19 Emergency N2O System 20 SITC of 2 Cylinder Emergency Nitrous Oxide manifold with All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders using a high flow Preset Pressure Regulator as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 21 MEDICAL CARBON DIOXIDE SYSTEM 22 CARBON DIOXIDE SYSTEM 23 The CO2 cylinder manifold should comprise of two cylinder Banks which can accommodate 4 cylinders in each Bank (means 4+4) for cylinder valves conforming to IS 3234 (CO2@ service) complete with copper tail pipes with fittings. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Nitrous Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves.High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Each manifold should be provided with one terminal header and a NPT connection for the Automatic control panel. Make- Altos/Aktiv or Equivalent 24 Certifications: ISO 13485:2016,ISO 9001:2015, CE 25 Fully Automatic Carbon DioxideGas Control System 26 SITC of Fully Automatic Control Panel for Carbon dioxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel.The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Micro processor controlled switch-over is accomplished automaticallyAutomatically resets itself for next cycle when depleted bank is replenished. No manual resetting requiredDigital pressure indication for accurate readingPressure unit options: bar, psi & kg/cm Status indicatorsPressure Stabilizer for stable discharge pressure & flowVisual & Audible signalDesigned to suit CO2 for gas specific usageOptimized residual gasMake-Altos/Aktiv or Equivalent 27 Emergency CO2 System 28 The Emergency supply manifold shouldbe connected to downstream of the manifold control panel.The assemblyshould consist of 2 (two) cylinders connection supplying a manually adjusted regulator via a common header assembly. The delivery system is isolated from the main system by an isolation valve. Pressure gauges should indicate cylinder and delivery pressure & valves conforming to ISO 13485Make- Altos/Aktiv or Equivalent 29 MEDICAL VACUUM SYSTEM 30 SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION 31 Vacuum Pump : The arrangement should consist of 2 nos. of oil lubricated imported rotary vane vacuum pump. Each vacuum pump should have capacity of 5000 lpm with IEC Motor rating of minimum 10 HP @ 50 Hz or above. Vacuum pumps shall comprise of air cooled, oil lubricated rotary vane vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525 mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed. The Vacuum Pump should be air cooled and oil lubricated rotary vane vacuum pumps designed for use in the field of high quality vacuum. It should be a robust construction, reliable operation, highly resilient carbon composite fiber vanes, Gas ballast valve. The pump should be having a 4 barriers system that avoids any oil leaks by doubling the 2 lip / shaft seals. Pump vanes shall be lubricated by a fully re-circulated and filtered lubricant supply. Also Pump design should include a lubricant separation system integral to the pump exhaust box consisting of no less than four stages of internally installed lubricant and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, lubricant mist elimination, smoke elimination, synthetic lubricant baffle, and shall be capable of removing 99.9 percent of all lubricant and smoke particles from the exhaust gas stream. The unit should have extremely low vibration as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- multitech/hitachi/Anistaiwata or Equivalent 32 Vacuum Tank of 5000 liters water capacity.Make- multitech/hitachi or Equivalent 33 Bacterial Filter:Vacuum Filter (Bacteria Filter) of 100 cfm to 105 cfm – 3” Filter housing with drain flask.: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards.The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplest, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969. The Vacuum filtration efficiency should be in excess of 99.9999% as per HTM0201 & AS 2896 standards. The high efficiency medical grade filter element should have custom engineered filter media and deep pleat element technology provides minimal pressure loss and filtration efficiencies. It should have advanced filtration technology for Low pressure loss borosilicate glass microfiber-media and open cell reticulated foam pre-filtration layer captures particulates, bacteria and liquid aerosols reducing energy consumption and overall system costs. It should have corrosion protection Internal and external electrophoretic painting followed by a tough exterior polyester powder coating.It should have easily removable sterilisable drain flask and differential pressure monitor gauge. It should have push fit element design for quick and easy maintenance with unique push fit element design. It should have element end cap color black. It should have maximum temperature 60 degree centigrade (140 degree F). It should have element of E31140MV grade. It should have pipe size connection 1” = 105scfm and 180nm3/hr FAA. It should have pressure loss clean & dry = < 3kPa (30m/bar/0.44psig). It should have maximum working pressure 0.5barg(7psig. It should have manual drain valves and 250ml sterilisable glass drain flasks.(Maximum tolearance allowed will be only 10%).Smooth mobility.Sturdy trolley mounted on 5 castor base wheels.Operational when connected to centralized vacuum.Fast connection to the vacuum source.Various Vacuum Connector options.Controllable & Stable vacuum for procedure.Step-less vacuum regulation within the range.Gauge needle with anticlockwise movement .Vacuum trap with bacterial filter in series to protect.system networkDisposable hydrophobic filter element.Quick hassle-free replacement of bacterial filter.Switch toselect collection jar & quicksuction shut-off.Easy access to selector switch.90 degree angular interface connectors to push-fit catheters.Autoclavable Polycarbonate collection jars.Overflow prevention trap on each collection jar.Make- Tridentor Equivalent 34 Ward Vacuum Unit with Regulator, Collection Jar of 1000 ml with Bracket.Make- Altos/Aktiv or Equivalent 35 Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 4000 ml Polycarbonate.Make- Altos/Aktiv or Equivalent 36 Bacteria Filter (Plastic) for 100 ml Safety Trap before Vacuum RegulatorMake- Altos/Aktiv or Equivalent 37 COMPRESSED AIR SYSTEM 38 SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION 39 Oil Free Scroll Air Compressor: The arrangement should consist of 2 nos.oil free scroll air compressor. It should be rated for 50 Hz, 3 Phase, 415 VAC power supply. Motor rating of each compressor should be 22 Kw & 30 Hp. Each scroll compressor should have a flow capacity of minimum 73 cfm (2070 LPM). The scroll air compressors shall be air cooled. Compressors shall be oil free scroll compressors suitable for both continuous and frequent start/stop operation having outlet pressure control range of 800 to 1000 kPa (8 to 10 bar). Each compressor shall have at least two individual scroll elements. The air quality shall be 100% oil free, certified ISO8573-1. The compressor shall have a sound insulating enclosure. Each scroll air Compressor should have an element consists of a fixed scroll shaped housing and a scroll shaped rotor. Air enters the compressor element through inlet opening. Once the air is drawn in, the orbiting scroll seals the inlet opening and forces the air into a continuously decreasing space. As scroll keeps orbiting, this process of compression is constantly repeated, resulting in discharging of oil free compressed air through outlet opening. Air is drawn through air filter and should be compressed by the compressor element of each compressor module. The compressed air is discharged via the check valve and a common air cooler. The cooling air is blown over the compressor element via a duct. A separate electric fan provides cooling air for the common air cooler. Each set of compressor modules has its own common aftercooler with an electric fan. The separator on compressors without integrated dryer has an automatic condensate outlet and a manual drain valve. The air compressors with integrated dryer, the dryer is equipped with a trap with an automatic condensate outlet and a manual drain valve. Each compressor element is protected by a sensor in the outlet pipe. The sensor is connected to the electronic regulator. Make- multitech/hitachi/Anistaiwata or Equivalent 40 Air Receiver of 5000 Liter Water Capacity (designed to withstand pressure of 10 Bar) with Auto Drain ValveMake-multitech/ hitachi or Equivalent 41 Medical Breathing Air Dryer- 375 SCFM - Medical air dryer heatless with purification modules are intended to provide a continuous supply of medical quality air conforming to the European Pharmacopoeia medicinal air monograph (ref. 1238), for respiratory use in healthcare facilities. The system shall be duplex such that the supply is maintained in single fault condition. Medical compressors shall be provided such that the specified volumetric flow is achieved without standby or backup systems running. Purification Module : The duplexed filter and dryer module shall incorporate high efficiency oil coalescing filters, heatless regenerative desiccant dryers, activated carbon filters and bacterial filters. The performance of the filters shall be according to below specifications: Oil coalescing high efficiency filter: mass efficiency of 99,92%, tested according to ISO 8573-2 & ISO 12500-1; Activated carbon filter: max remaining total oil content of 0,003 mg/m³, tested according to ISO 8573-5 & ISO12500-2;Bacterial filter: particle count efficiency of 99,98% at MPPS=0.06μm, tested according to ISO 12500-3. Dryer Purge Control : The dryer control system shall incorporate a Purge Saver Energy Management system that freezes the regeneration of the desiccant once adequate dew point is reached in the inactive tower. Only when the dewpoint level in the active tower deteriorates to an unacceptable level will the intelligent controller switch towers.Coarse coalescing filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of red color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 1 micron. It should have maximum particle size class 2 micron as per ISO 8573-1: 2010 . It should have maximum oil content 3 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68 degree F (20degree centigrade) = 0.3ppm (0.3mg/m3). It should have pressure loss clean & dry = 0.8psi (55m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). 42 Fine coalescing filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of blue color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.01ppm (0.01mg/m3). It should have pressure loss clean & dry = 1.2psi (85m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). Activated Carbon Filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of black color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.003ppm (0.003mg/m3). It should have pressure loss clean & dry = 1.7psi (115m/bar). 43 Fine Dust Filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element blue color end caps for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have pressure loss clean & dry = 1.5psi (100m/bar). Make- Trident or Equivalent 44 Pressure Reducing Station for 4 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 4 bar for medical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 4 bar stations - 5.5 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 10000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 45 Pressure Reducing Station for 7 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 7 bar for surgical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 7 bar stations - 9 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 4000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 46 SITC of Medical Gas Outlets- 47 Probes are crucial for gas specific and stable connection. These are used to connect medical gases and vacuum devices to outlets / terminal units of MGPS distribution network.Make- Altos/Altos/Aktiv or Equivalent 48 FeaturesSmooth quiet action.Safe keying configurations.Gas specific ISO 32 colour coding.Firm locking of connector / probe.Strong, positive and secure connection.Corrosion-free and material compatibility.Reliable and safe dispense of gases & vacuum.Pipe stub end flared to align drop pipe and to avoid butt joint. 49 Oxygen 50 Air-4 51 Air-7 52 N2O 53 AGSS 54 Vacuum 55 CO2 56 Certifications:ISO 13485:2016 – Medical devices,ISO 9001:2015 57 MISCELLANEOUS ITEMS 58 SITC of Common Electrical Control Panel for Compressed Air System, Vacuum System & AGSS as per requirementcomplete with plant room wiring. 59 SITC of Degreased Medical Grade Copper Pipe as per EN 13348 :2018. BSI Kite Mark certified. CE Certified. Third Party Inspection by TUV or Lloyds Registrara AsiaMake- Altos/Altos/Aktiv or Equivalent 60 Installation of piping should be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards should be used . Pipe fixing clamps for upto 28mm diameter. Pipes should be non ferrous suitable for the diameter of the pipe. For the pipes of the sized above 28mm rigid metallic hanging or cemented supports to be used. 61 The main lines to the building to be taken overhead through metallic poles or through underground ductswith inspection removable slabs,All pipe joints should be made using inert gas fluxless brazing method.Alljoints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation ofcopper oxide on the inside surface of the joint.All pipes should be installed without springing or forcing.All pipes shouldprotected against mechanical injury in a manner satisfactory to authorities havingjurisdiction. 62 Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas.Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours. 63 Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per international standards.All concealed pipes to have gas identification bands / labels at appropriate distance.Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. 64 Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS: EN 13348. 65 All copper pipes will beUL certified for medical use before dispatch and the pipe will be delivered plugged or capped at both ends. 66 108 mm OD X 1.5 mm thick 67 76 mm OD x 1.5 mm thick 68 54 mm OD x 1.2 mm thick 69 42 mm OD x 1.2 mm thick 70 35mm OD x 1.2mm thick 71 28 mm OD x 1 mm thick 72 22 mm OD x 1 mm thick 73 15 mm OD x 1 mm thick 74 12 mm OD x 0.7 mm thick 75 SITC of Medical Gas Digital Area Alarm System 76 Microprocessor based digital LCD alarmHighly visible 7 (178 mm) LCD screenPressure sensing through piezoresistive sensing technologyAlarms can be monitored audio-visualTouch screen operationComprehensive monitoring of all the medical gas alarm panelsData display at a central monitoring station Features-Alarm status will be visible through ethernet port on master alarmPressure Equipment Directive 2014/68/EUDigital Flow Care Alarm Management of Medical Gas Pipeline SystemReal time updating of statusOperational parameters i.e. high and low level canbe set “in-situ” to suit requirement in an area 2Programmable pressure unit display (bar, kg/cm & mmHg)Audio mute optionDesigned to serve 2, 3, 4, 5 & 6 gases including VacuumNIST connection for Gas inputPowered by 220V AC to 24V DC external adapterMake-Altos/Aktivor Equivalent 77 Conforms to: IS / ISO 7396 - 1 : 2016 + A1 : 2017HTM 02-01 Part A, IS / ISO IEC 60601 - 1 : 2015 + A1 : 2020Certifications:ISO 13485:2016 – Medical devices – Quality Management SystemsISO 9001:2015 - Quality Management Systems 78 6 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar, Vacuum & CO2) 79 5 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar & Vacuum) 80 4 - Gas (O2, N2O, Med Air-4 Bar & Vacuum) 81 3 - Gas (O2, Med Air-4 Bar & Vacuum) 82 2 - Gas (O2 & Vacuum) 83 SITC Of Area Valve Service Unit with Valve & Gauge 84 The importance of full bore ball valves is to reduce pressure drop to almost negligible in the pipeline distribution system so that the designed pressure is available at the outlet point. Ball Valves are used to start or stop a flow. In Medical Gas Pipeline System (MGPS), the valves are normally kept open i.e. allow the gas to flow unless it is required to shut-off the gas supply for scheduled maintenance or emergency situation 85 Features-Operational parameters can be set in-situDigital pressure unit display options -psi / bar or kg/cmDigital & illuminated LED display of “Normal”, “High” & “Low”Microprocessor based moduleHighly accurate “Heavy Duty” pressure transducerPowder coated aesthetically designed enclosureEnclosure separable from the base for ease of installationReusable lock assemblyAudio mute optionPED: 2014/68/EU certified full port Ball Valve (PN 30)Long extension copper pipes to connect MGPS networkFront door opens up vertically for comfortable accessDesigned to serve 2, 3, 4 & 5 gas moduleSuitable for all medical Gases & VacuumMake- Altos/Aktiv or Equivalent 86 6 Gas Service (O2, N2O, Med Air-4 Bar,Air-7 Bar, Vacuum & CO2) 87 5 Gas Service(O2, N2O, Med Air-4 Bar, Air-7 Bar & Vacuum) 88 4 Gas Service(O2, N2O, Med Air-4 Bar & Vacuum) 89 3 Gas Service (O2, Med Air-4 Bar & Vacuum) 90 2 Gas Service(O2 & Vacuum) 91 SITC of Degreased Medical Lockable Ball Valve with Pipe line assembly 92 Pre piped single port) for size upto 2 (for 54mm copper pipe): Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It shouldbe blow-out proof stem. It should be lockable valve. The Valve shall be 3 piece ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton for 1/2” - 4” valves. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa].Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Valves shall be designed in such a manner that it can be “swung-out” during installation so as to prevent damage due to heat transfer during the brazing operation. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation.Make- Altos/Aktiv or Equivalent 93 12mm 94 15 mm 95 22 mm 96 28 mm 97 35mm 98 42 mm 99 54 mm 100 108mm 101 SITC of Bed Head Panel aluminum powder coated with mininum 3 channel and 3 duct with separate partition rows and built in aluminum railMake- Altos/Aktiv or Equivalent 102 Bedhead panel for Low Equity Ward Areas, 1500mm length, with provision of Gas outlets & provided with electrical sockets & accessories complete 103 Horizontal Bed Head Panel – For 2 Gas Service (Oxygen & Vacuum) 104 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, Med Air-4 Bar & Vacuum) 105 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, N2O & Vacuum) 106 Horizontal Bed Head Panel – For 4 Gas Service (Oxygen, N2O, Med Air-4 Bar & Vacuum) 107 Special FeaturesInnovative design – Efficient, simple & accessibleVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outlet 108 Application AreasInnovative design – Efficient, simple & accessiblityVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outletAdult in-patient wards/ General WardsResuscitation RoomsPost-anaesthesia areaEmergency Admission WardsDialysis Stations 109 Configuration : 5 Outlets & 6 Multi Standard 220V AC sockets, 1 each RJ11 Telephone socket & RJ45 Data Socket and provision of protective earth (Earthing) 110 Modular Operation Theatre (Part-B) 111 WALL AND CEILING MODULAR PUF PANEL 112 The panels shall be made of durable and uniform material that shall be easy to clean and extremely hygienic. Operation theatre shall not have any sharp edges, corners and shall not support bacteriological or fungicidal growth and shall be resistant to most chemicals, commonly used in Hospital Departments. Joints in the panels in the operation theatre shall be sealed. The function of sealing shall assure an airtight environment in the room and eliminate services to prevent dust accumulation.PUF Panel with an overall thickness of 50 mm for wall and 30 mm for ceiling, made of 0.8mm (make-Tata/jindal)GI Front sheet and 0.6mm PPGI back wall with infill of PUF at 40 kg/m3 (40D)which is necessary for mechanical strength. Panels shall be mounted on a structure made of galvanized steel and shall enable the distribution of medical gases, electricity, sewerage inside the wall.PUF Panel as above has better thermal efficiency and thus saving on energy cost. Proposed system shall be installed at site without any welding.The partitions shall not have corners; adjacent surfaces shall be molded flush.Upper wall element shall have sufficient height to reach the lower edge of the prefabricated ceiling. All the sharp edges and corners should be chamfered to avoid bacterial contamination.The individual ceiling panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed,provides a seamless sub-structure, which is then sanded smooth finished with Metal Putty and then painted using imported anti-fungal paint to give a smooth, non-porous seamless finish and without corners by providing coving on floor as per standard.It is resistant to chemicals used in Operation Room for moping and fumigation repeatedly.Make-Jindal/Tata or Equivalent 113 WALL AND CEILING MODULAR PUF PANEL-SS304 114 The prefabricated Operating Room should be of SS Sandwich as per its latest standards. SS Sandwich : It should have at least min. 0.8 mm 304 Grade Stainless Steel on front side and 0.5mm PPGI back side . The sandwich panel shall have a core consisting of rigid polyurethane foam, injected under high pressure, with a minimum density of 40 kg/m3. Cladding structure insulated stainless steel wall panels with total panel thickness 50 mm for wall and 30mm for ceiling.The individual wall panels shall use tha tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler and sanded flush. Stainless steel plate finished to fine grain surface, treated properly to take antifungal paint panelingshould be easy to maintain, durable, antistatic / conductive and fire retardant. Clearance between inner panel and outer wall should be sufficient to allow the maintenance personnelfor service. This closed space should be flushed continuously to eliminate dust and bacterial accumulation.It should have minimum number of junctions. The junction should be seamless and should be sealed with suitable sealants. Third party test certificate for SS from material testing lab. (Govt. authorized)required.Make-Jindal/Tata or Equivalent 115 ANTI-FUNGAL PAINTING 116 Anti microbial Paint for Different Areas antibacterial Paint on wall and ceiling panels Inside OT work.Anti-Microbial Protection: These product hygiene coatings start the biocidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years.Minimum three coats of Anti Fungal/Bacterial Paint, glaze or equivalent to a minimum dry thickness of 300 microns to give smooth , non-porous finish without any corners.It will also be resistant to the chemicals used in Operation Room for Moping & Fumigation repeatedly. This Hygiene coating are independently tested by leading universities to demonstrate resistance.Make-SKK/ Jotun or Equivalent 117 PLENUM LAMINAR AIR-FLOW 118 Supply and installation of Plenum LAMINAR FLOW- Plenum Box Ceiling mounted systemwith unidirectional airflow, SPECIFICATIONS-PLENUM UNIT - The complete unit factory designed and manufactured with proper air-sealing. It seamlessly integrates with OT ceiling mounted equipment.Plenum size- 2400 x 2400mm with aluminium material.Diffusers are made of SS304 punched/perforated sheet for unidirectional diffusion air. The complete unit factory designed and manufactured with proper air-sealing.It seamlessly integrates with OT ceiling mounted equipment.The material used is non-corossive as per standard guidelines such as Aluminium.Make-Jindal/Tata or Equivalent 119 Hepa Filters- 120 The filter hosing on either side houses provided with HEPA minipleate H13/H14 filters.The system has a reliable filter efficiency, filters are designed to remove particles and germs with the use of H13/H14 filters retaining 99.97 % of the particles and germs.Frame : Aluminium Mini Pleat Size- 610x610x125mmMOC of the Media : Micro Fibre Glass micro drawn grid Separators : continuous Gasket: Food GradeMPPS average efficiency: > 99.95% 3 Micron D Efficiency: 99.97% down to 0.3µ.Maximum Operating Temp : 60 degree CelsiusMake- Thermadyne or Equivalent 121 ANTI-STATIC VINYL FLOORING: 122 SupplyandinstallationofImportedVinylFloor:SeamlessantistaticconductiveESDvinylflooringsystem,2mmthick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting.SPECIFICATIONS:- Flooringinoperationtheaterroomwii beseamless withperfectly curvedflash-covings,resistance tomechanicalstressanddynamicloadsandhavingESD/EMI(Conductive)protectioncharacteristics,2mmthick, washablevinyl.Flooring is a static-conductive,flexible homogeneousvinyl floor covering withan electricalresistance of 5x10^4 123 SELF LEVELLING MATERIAL. 124 The SLC should be of Portland cement-based, It should be self-leveling underlayment formulated with a special blend of polymersusedtolevelandsmoothinteriorconcrete,terrazzo,ceramicandquarrytile,epoxycoatingsystems,metal andnon-watersolubleadhesiveresidueonconcretepriortotheinstallationoffinishedflooring–on,aboveorbelow grade.TheSLCshouldprovideadurable,flat,smoothfloor surfacewithminimumlabor andinstallationtime.Itshould be pourable or pump-able when mixed with water and should seek its own level to produce a smooth, flat, hard surface. 125 OPERATION THEATRE CONTROL PANEL: 126 Supply and installation of Membrane type 6 services OT control panel , with distribution box mounted flush in the theatre wall, comprising of the following:The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations.The room Surgeon’s control panel should be modifiable with changing technology& equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose.he panel should be “Membrane” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance membrane with sterilization feature.The Panel should contain 6 or 9 service tiles as below:1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System.4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller.7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters.Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digitaltype & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre.The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures.A hand free set Telephone System should be incorporated in the panel with memory type card.The control panel should be designed for front- access only. All internal wires should beMake- Altos/DGline or Equivalent 127 Distribution Board outside OT 128 Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house the operating transformers, light control relays, electrical distribution equipment and circuit protection equipment for all circuits withinthe operating theatre. All internal wiring should terminate in connectors with screw mounted, on a DIN rail. Individual miniature circuit breakers will protect all internal circuits. All high voltage equipment should be installed in a separate enclosure.All internal wiring should terminate in connectors with screw & clamp springConnections of the clip- on type mounted, on a CE/ / ICMED9001/ ICMED13485 approved rail & labeled with indelible proprietary labels.Individual fuses or miniature circuit breakers should protect all internal circuits. 129 LED PERIPHERAL/GENERAL LIGHTS: 130 Recess mounted sealed IP54 Protocol, non-hygroscopic peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED, with optical anti- glare system for individually adjustable light distribution.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated steel frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Control equipment for the general lighting and the light dimming should be provided in the theatre Control Panel.Make-Altos/DGline or Equivalent 131 LED X-RAY VIEW PANEL: 132 TwoPlateX-RayViewScreenwithflickerfreeilluminationhavingimportedLEDsystemforuniformilluminationand operated by X-ray film .Thesystemhavingelectricalsafetycodesforhigh&Lowvoltagesystem.Itshouldbedesignedtoprovideflickerfree luminance for the film viewing purpose.It should be installed flushed with the theatre wall for hygiene and ease of cleaning.Make-Altos/DGline or Equivalent 133 MAGNETIC LISTING WRITING BOARD: 134 MagneticWritingBoard of size940x 640x50mmcomprisesof aflushmounted,1.50mmthick,whitelaminate board, bonded toa 10 mm high density fibreboard sheet for additional rigidity.The writing unit should comprise of flush mounted white laminate board, be opened to create a wall mounted writing surface within the operating room. The white board should be constructed from white laminate board.Make- Altos/Dgline or Equivalent 135 AUTOMATIC HERMETICALLY SEALING SLIDING DOOR -1500mmX2100mm 136 Automaticoperated Hermettically Slidingdoor with High Pressure Laminate on both side, Door size (1500mm wide2100mmheight)completewithdoubletoughnedglassvisionwindowof300mmx300mm withinanaluminum extrusionhighqualityframecompletewithrequiredaccessories.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings that are adjustable during installation to ensure sealing.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door HandleMake-Metaflex/Doormedor Equivalent 137 HERMETICALLY SEALING HING DOOR-900mmX2100mm 138 Manually operated Hermettically Semi- sealed Hing door with HighPressure Laminateon bothside, Door size (900mm wide x 2100mm height) complete with double toughned glass vision window of300mm x300mm andsmooth effortless doorcompletewithrequiredaccessories,fixedfirmlytothewall.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be hinge mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door Handle. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door.Make-Metaflex/Doormed or Equivalent 139 CORNER GRILLS 140 Aluminium corner grills are used to air exhaust at all four corners.size of grill will be 600mmX400mm.Duly powder coated extruded aluminium linear horizontalfixed bar with normal 15 deg. blade having pitch of 13 mm.Exhaust Gril for return air-The exhaust air cabinets should be openable and cleanable. These cabinets should have suction from bottom.Distribution of exhaust air volume should be divided between fluff strainers to maintain the required pressure within the theatre without causing turbulence.The Exhaust air cabinet should be manufactured and supplied by the supplier of wall and ceiling system supplies. Also it should match perfectly with the ceiling system aesthetically.Make-conair/Bala ji engineering or Equivalent 141 ALUMINIUM DUCTING: 142 Aluminium Ducting ( 22 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication.Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart.Thermal insulation with 9/13mm XPE with aluminium foil for supply & return air ducts.Joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 6 meter.SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc.Make-Hindalco/Virgo or Equivalent 143 AIR HANDLING UNIT 144 AHU System & Condensing Unit with consistingDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GI Frame Work Hollow Extruded AL Profile Thickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material ofDrain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base Channel DX COIL: Make Of Coil ZECO Coil Casing / Blank offs GI Material Of Tube Copper (IGT) Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material Copper Thickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12 FILTERS: Media of Filters Synthetic (non woven type) Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron FAN & MOTOR: Fan make Nicotra Motor make CG Motor type TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor VFD: VFD make DELTA DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE:(WITH 25MM THICK PANEL) ◻ Mixing box with manually operated FA & RA damper in GI constructionDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GIFrame Work Hollow Extruded AL ProfileThickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material of Drain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base ChannelDX COIL: Dx type coils having suitable number of distributors for connecting expansion valve with condensing unitsMake-Zeco//VTS or Equivalent 145 Make Of Coil Casing / Blank offs GI Material Of Tube Copper (IGT)Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material CopperThickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12FILTERS: Media of Filters Synthetic (non woven type)Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron VFD: DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE: (WITH 25MM THICK PANEL)Mixing box with manually operated FA & RA damper in GI constructions.Filter section with 50 mm thick (EU-4) box type pre filter with 305 mm thick (EU-5) bag type fine filter mounted on common filter frameCoil section with 6 row deep DX cooling coil with suitable distributor. Heater Section with GI strip Heater.Fan section with SISWbackward curved plug fan & Motor (IE-2). Manually operated SA damper in GI construction.Tonnage TR 8.5 Air Qty (CFM) 3500SP (mm wg) 125 UnitFan Type Plug Fan-355Fan model RLC E6-3135-23-19 Fan RPM 3400Motor RPM 2880Shaft Absorbing Power 3.2 Motor Rating (kw) 3.7 Motor pole 2Coil area (Sq.Ft.) 7.0 DX Cooling Coil RD 6 Distributor 1Heater KW3Filter area (Sq.Ft.) 8.0 Length (mm) 2500Width (mm) 1400 Height (mm) 945 146 AIRCONDITIONING: (8.5 T AC ) 147 Nominal Cooling Capacity-8.5tr,102000Btu/hr,29894watt Nominal Air Quantity-6250CFMPower Supply (V-ph-Hz)-400 ± 10% -3-5 Fan-PropellerDischarge-HorizontalFan Motor-Permanent Split Capacitor Type Power (watt)-470Control Type-LED DisplayOverall dimensions (mm)-982 X 610 X 1100 mm- Compressor- Scroll CompressorRefrigerant-R-410A (5.6) Liquid Line-5/8Suction Line-1-1/8Make- Carrier or Equivalent 148 ELECTRICAL WIRING INSIDE THE OT 149 Electrical Wiring as per requirement of OT, Wiring With OT distribution electrical Panel. ( Power cable at OT with Main distribution Panel will be provided by customer) Operation theatre shall be installed in the remote cabinet.All electrical wiring should be terminated to the connectors mounted on DIN/CE approved rail and labeled with indelible labels.Individual fuse and miniature circuit breakers should protect all internal circuits.Complete schematic diagram drawing description should be enclosed with the equipment. Makes:Scheinder/PolyCab/ Schematic.Supply, Installation, Testing and Commisnoing of Electrical Distribution Board with required MCB : It should be installed in a separate enclosure.Transformers,Mains,Relays,Circuitprotectiveequipment,forallcircuitsofOperationtheatreshallbeinstalledinthe remote cabinet. 150 MEDICAL GAS PIPE-LINE SYSTEM INSIDE OT 151 Medical Gas Pipe Line inside the OT above ceiling as required, complete with valve box and other required fitings. Medical Gas copper pipeline inside the OT and the Provision to connect to Pendant Systems (inside OT only).It should be confirm and meets with BS:EN:13348:2008 copper pipes.All medical grade degreased copper pipes must be inspected and duly Third Party Certified by Lloyd’s Registered Asia. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW024A (Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2008 & 250 or 290 (Half hard).Degreasing of pipe shall be such that there is less than 20 mg/m2(0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS:EN:13348:2008.Make- Altos/Aktiv/Mandev tubes/Mehta tubes or Equivalent 152 PASS BOX SIZE-2FTX2FTX2FT 153 Pass Box to remove the waste materials from the Operation Room to the Dirty Linen Area. Each box is equipped with two doors and the door should be operated electronically.. It is designed in such a way that only one door can be opened at one time. UV light is so installed that it is kept on while both the doors are closed and turned off automatically when the doors are opened. Indicators on both side of the Operation Room for Door Open/Close status. It is made of SS-304 Grade.Make- Jindal/Tata or Equivalent 154 STORAGE UNIT 155 Storage Unit of size 850x1600x350 mm has made of 1.6mm galvanised steel sheet. The exterior glass doors has lockable with magnetic push-button for easy opening. Removable toughened glass shelves of thickness 5 mm will be provided with the storage units.Make- Jindal/Tata or Equivalent 156 Pressure Relief Dampers 157 Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areasCounter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room.Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance.The PRD should remain closed at pressure below the set pressure and should open fully at a pressure only fractionally above the threshold pressure.The body of PRD sleeve and Grill should be epoxy powder coated as per standard High grade SS304 Stainless steel plate should be used for body and for bladesMake- Jindal/Tata or Equivalent 158 OT Pendant –Single Arm Anesthesia(Modular) 159 Anesthesia Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.Make- Altos/Aktiv or Equivalent 160 The Pendant Service Heads / column should be supplied with medical gas terminal units. The medicalgas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard. 161 Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 2 no, Air (4 Bar) – 2 no, Vac – 2 nos, AGSS – 1 no. Medical rail with brake buttons fitted. - 1 No.Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its lengt 162 OT Pendant -SURGICAL PENDANT : 163 Surgon Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.The Pendant Service Heads / column should be supplied with medical gas terminal units. The medical gas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard.Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 1 no, Air (4 Bar) – 1 no, Vac – 2 nos.Medical rail with brake buttons fitted. - 1 No.Make- Altos/Aktiv or Equivalent 164 Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its length. 165 UV LIGHT INSDIE OT FOR CLEAN/STERILIZE PERPOSE SIZE-2FTX1FT 166 Recess mounted sealed IP54 Protocol, non-hygroscopic UV peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED. Ultraviolet (UV) lamps are commonly used in operation theatres for disinfection.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Make- Altos/Dgline or Equivalent 167 Surgical Scrub Station – Two Bay 168 Compact surgical scrub sink should be designed for use in OT complex providing for pre – OT scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel and should be seamless welded construction, polished to a satin finish.The washing faucet shall be made of Chrome plated brass hand. The station shall be equipped with soap dispensers made of SS 304 grade.The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers.Hands free operation should include infra red sensors with built-in range of adjustment.The scrub station shall be made of high-grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971.Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of 1,3,6 & 10 min should be available. This timing should be adjustable to meet individual application requirements.All units should have reduced anti- splash fronts.The scrub stations control system shall be based on advanced microprocessorThe scrub station shall be sensor-activated 24VAC and should have the provision to operate it manually in case of power failure by using foot switch or knee switchimported thermostatic mixing valve for Hot & Cold water, Strainers, Spouts & manual foot operated valve system.Make- Jindal/Tata or Equivalent 169 AUTOMATIC PHASE SEQUENCE CONTROLLER 170 PMC Based (Pre magnetic Contractor)63A Double interlock & time Delay systemAuto/Manual Operation Sie- 140 x 275 x 320 mm Smooth and fasr Switchingworks well even at high & low voltages. Wide Current rnge.Voltage Range-130-280Vac Temperature- 55 Degree Celsius Auto mode Selector switchDigital micro Control relay for sequence management.LED Indicator for complete status of power.Make- Subtech or Equivalent 171 Operation Theatre Light - LED type, Camera Ready (Triple Arm) 172 Operating Room Surgical Lighting system should provde an ideal combination of broghtness, maneuverability, and shadow resolution without sacrificing color accuracy throuh a consistent LED technology. Such Lighting System should have the following technical specifications: 173 a. Number of light heads : Two per suspensionb. Colour Temperature range : 3800k-5000 (±10%) - Variable color temperature. c. Field Size Diameter : 20 to 28 cm (+/- 10%)d. Working range : 750 to 11100 mm (+/- 10 %)e. Illumination Level : 160000Lux (major Dome & Minor dome )f. Rotation : 360 - 330 degree g. Sterilizable Handle : 02 Nos h. Mounting type : Ceiling i. Supply Voltage : 230 VAC 50 Hz j. Bulb Type : LEDk. Dimming Range : 50% - 100%l. Operating / Storage Humidity : 10 - 95 %m. Life of Light source : > 40,000 Hrs n. Should be provision to mount the camera in 1 dome . o. Surgical Light System Should be compliant with relevant European CE / US FDA standardsMake- HillRom/Steris orEquivalent 174 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
48.
Housing Urban and Rular Development #9456640 Technical Bid
Tender For Tourists Facilitation Cenre Near Kalinjer Fort Banda, District Banda (U.P.), 1 Tourists Facilitation Cenre Near Kalinjer Fort Banda, District Banda (U.P.) 2 CIVIL WORK 3 Earth work in excavation by mechanical means(Hydraulicexcavator)/manualmeans over areas (exceeding 30cm in depth. 1.5m in widthaswellas10Sqmonplan)including disposal of excavated earth, lead upto 50m and liftupto1.5m,disposedearthtobelevelled and neatly dressed. 4 Fillingavailableexcavated earth(excluding rock)intrenches,plinth,sidesoffoundations etc.inlayersnotexceeding20cmindepth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport uptoaleadof5kmalsoincludingramming and watering of the earth in layers not exceeding20cmintrenches,plinth,sidesof foundation etc. complete. 6 Providing and laying inposition cement concrete of specified grade excluding the cost ofcenteringandshuttering-Allworkupto plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 8 Treatmentofsoilunderexistingfloorsusing chemicalemulsion@onelitreperhole,300 mmapartincludingdrilling12mmdiameter holes and plugging with cement mortar 1:2 (1 cement:2coarsesand)tomatchtheexisting floor. WithChlorpyriphos/ Linadane E.C. 20% with 1% concentration. 9 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping chargesLintel. Ground Floor 10 First Floor 11 Second Floor 12 Terrace Floor 13 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Slab Ground Floor 14 First Floor 15 Second Floor 16 Terrace Floor 17 Ready mix concrete M 25 = 1.00 cum. i/cplacing of concrete, vibrating, leveling etc5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCCGround Floor Tie Beam 18 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Slab BeamGround Flooor 19 First Floor 20 Second Floor 21 Terrace Floor 22 Ready mix concrete M 25 = 1.00 cum. i/cplacing of concrete, vibrating, leveling etc5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC. Raft Foundation 23 Ready mix concrete M 25 = 1.00 cum. i/cplacing of concrete, vibrating, leveling etc5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC. Column Ground Floor upto plinth level 24 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Column Ground Floor 25 First Floor 26 Second Floor 27 Terrace Floor 28 BrickworkwithcommonburntclayF.P.S. (nonmodular)bricksofclassdesignation7.5 in foundation and plinth in:Cement mortar 1:6(1 cement : 6 coarse sand) 29 Providingandlayingdamp-proofcourse40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5 mm nominal size). 30 Paintingon D.P.C. withtwocoatsof airblown bitumen 85/50 or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any. 31 BrickworkwithcommonburntclayF.P.S. (nonmodular)bricksofclassdesignation7.5 in superstructure above plinth level up to floor Vlevelinallshapesandsizesin:Cement mortar 1:6 (1 cement : 6 coarse sand) Ground Floor 32 First Floor 33 Second Floor 34 Terrace Floor 35 HalfbrickmasonrywithcommonburntclayF.P.S. (non modular) bricks of class designation7.5 insuperstructureabove plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) Ground Floor 36 First Floor 37 Second Floor 38 Terrace Floor 39 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionandbindingallcompleteuptoplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. Ground Floor 40 First Floor 41 Second Floor 42 Terrace Floor 43 15 mm cement plaster on rough side of single orhalfbrickwallofmix:1:4(1cement:4coarse sand). 44 15 mm cement plaster on rough side of single orhalfbrickwallofmix:1:6(1cement:6coarse sand) Ground Floor 45 First Floor 46 Second Floor 47 Terrace Floor 48 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) Ground Floor 49 First Floor 50 Second Floor 51 Terrace Floor 52 ProvidingandlayingMoroccan floortilesin different sizes (thickness to be specified by the lasa brand ) withwater absorptionless than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with greycement [email protected]/sqmincludinggroutingthe jointswithwhitecementandmatching pigmentsetc.,complete.SizeofTile300x300 mm Ground Floor 53 First Floor 54 Second Floor 55 Terrace Floor 56 Providing and laying Moroccan tiles in different sizes (thicknessto be specified by manufacturer), with water absorption less than0.08 % and conforming to I.S. 15622, of approvedmake,inallcolours&shade,in skirting,riser of steps,over12mmthick bed of cement mortar1:3 (1 cement:3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement& matching pigments etc. complete.Size of Tile 300x300 mm Ground Floor 57 First Floor 58 Second Floor 59 Terrace Floor 60 Providing and fixing 18mm thick gang saw cut mirrorpolishedpremouldedandprepolished) machine cut for kitchen platforms, vanity counters,windowsills ,faciasand similar locationsofrequiredsizeofapprovedshade, colour andtexture laidover 20mmthick base cementmortar 1:4(1cement: 4coarse sand) withjointstreatedwithwhitecement,mixed with matching pigment, epoxy touch ups, includingrubbing,curing,mouldingand polishing to edges to give high gloss finish etc. completeatalllevels.Graniteofanycolour and shade. Ground Floor 61 First Floor 62 Second Floor 63 Terrace Floor 64 Providingandfixing18mmthickgangsaw cut, mirror polished,premoulded and prepolished,machinecutforkitchen platforms,vanitycounters,windowsills, facias and similar locations of required size, approvedshade,colourandtexturelaid over20 mm thick base cementmortar 1:4 (1 cement:4coarsesand),jointstreatedwith whitecement,mixedwithmatchingpigment, epoxytouchups,includingrubbing, curing,moulding andpolishing to edges to give high gloss finish etc. completeat all levels.Graniteofanycolour and shade. Ground Floor 65 First Floor 66 Second Floor 67 Terrace Floor 68 Providing and laying Ceramic glazed floor tilesofsize300x300mm(thicknesstobe specifiedbythemanufacturer)of1stquality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing thejointswithwhitecementandmatching pigment etc., complete. Ground Floor 69 First Floor 70 Second Floor 71 Terrace Floor 72 Providing and fixing Ist quality ceramic glazed walltilesconformingtoIS:15622(thickness tobespecifiedby the anufacturer),of approvedmake,inallcolours,shadesexcept burgundy,bottlegreen,blackofanysizeas approvedbyEngineer-in-Charge,inskirting, risersofstepsanddados,over12mmthick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing withgrey cementslurry @ 3.3kgpersqm,includingpointinginwhite cement mixed with pigment of matching shade complete. Ground Floor 73 First Floor 74 Second Floor 75 Terrace Floor 76 Kota stone slab flooring over 20 mm (average) thickbaselaidoverandjointed withgrey cementslurrymixedwithpigmenttomatch theshadeoftheslab,includingrubbingand polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick Ground Floor 77 First Floor 78 Second Floor 79 Terrace Floor 80 Kotastoneslabs20mmthickinrisersof steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarsesand)and jointedwith greycement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete. Ground Floor 81 First Floor 82 Second Floor 83 Terrace Floor 84 Making plinth protection 50mm thick of cementconcrete1:3:6(1cement:3coarse sand (zone-III) derived from natural sources : 6 gradedstoneaggregate20mmnominalsize derived from natural sources) over 75mm thick bedof dry brick ballast40mmnominalsize, wellrammedandconsolidatedandgrouted withfinesand,includingnecessary excavation,levelling&dressing&finishing the top smooth. 85 ProvidingandfixingISImarkedflushdoor shutters conforming to IS : 2202(Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering withverticalgrainsorcrossbandsandface veneers on both faces of shutters: (a)35mmthickincludingISImarked Stainless Steel butt hinges with necessaryscrews. Single leaf. 86 (b) Double leaf 87 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. Theprofile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frameshall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastner with necesary stainless steelscrews, all complete as per direction of Engineer-in-charge 88 Specifications for cupboard shutter, lipping in pelmet, teak wood lipping, uPVC casement/sliding window & door and Fire resistant glazed doors, windows & partition have been incorporated have been added. The specification Clauseshiftedto Sub Head 8 (cladding work) under clause No. 8.15. Specification of Nickel plated M.S. Pipe curtain roads, M.S. grills in frames of window, Bamboo Jaffery/ fencing, wooden moulded corner beading, magnetic catchers, powder coated telescopic drawer channel, slidling arrangement in racks/ cupboards/ cabinets shutter, hardware fittings for uPVC door/ windows, prelaminated medium density fibre board and stainless handles have been incorporated. 89 Providing and fixing factory made door frame (single rebate) made out of single piece extrudedsolidPVCfoamprofilewith homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement,includingfixingtheframetowall withsuitabledia&lengthanchorfasteneras permanufacturersspecificationand irection of Engineer-in-charge. 90 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Ground Floor 91 First Floor 92 Second Floor 93 Terrace Floor 94 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 116.90 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqmGround Floor 95 First Floor 96 Second Floor 97 Terrace Floor 98 Providingandapplyingwhitecementbased putty of average thickness 1 mm, of approved brandandmanufacturer,overtheplastered wallsurfaceto preparethe surfaceevenand smooth complete. Ground Floor 99 First Floor 100 Second Floor 101 Terrace Floor 102 Providingandfixing150mmbrightfinished floor brass door stopper with rubber cushion, necessarybrassscrewsetc.to suitshutter thickness complete. 103 Providing&fixingStainlesssteelslidingdoor bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 104 Providingand fixing stainless steel towerbolts (barreltype)withnecessaryscrewsetc.complete (a) 300 mm x 10mm 105 (b) 200 x 10mm 106 Providing and fixing stainless steelhandles with screws etc. complete (a) 125 mm 107 Providing & fixing glass planes with putty and glazingclipsinsteeldoors,windows, clerestorywindows,allcompletewith:4.0mm thick glass panes 108 Construction of drain alongwith apron. 109 Chequerredprecastcementconcretetiles22 mm thick in footpath & courtyard, jointed with neat cement slurrymixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4(1cement: 4coarse sand).Ordinary cement without any pigment 110 Fitting of cast iron railing 111 Extra for openable side / top hung vision glass panels (IGUs)includingproviding and supplying at site all accessories and hardwares for the openable panels as specified and of the approvedmakesuchasheavydutystainless steelfrictionhinges,min4-pointcremone lockingsetswithstainlesssteelplates, handles,buffersetc.includingnecessary stainlesssteelscrews/fasteners,nuts,bolts, washersetc.allcompleteasperthe Architecturaldrawings,aspertheapproved shop drawings, as specified and as directed by the Engineer- in- Charge. 112 Providing and applying 12 mm thick (average) premixed formulatedone coat gypsum lightweight plaster having additives and light weightaggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part- 1 & II) 1976, applied on hacked / uneven background such as bare brick/block/ RCC work on walls & ceiling at all floors and locations, finished insmooth line and level etc. complete. sqm 468.90 113 Shingles roof tilesThe cement-mortar ratio for tile roofing is typically 1:3, which means 1 part cement and 3 parts sand. This ratio is suitable for most types of tile installation, including ceramic and porcelain tiles. The thickness of the mortar bed for tile flooring should be at least 3/8 inch, but no more than 3/4 inch 114 Planting and greenery with installation as per given details 115 ELECTRICAL WORK 116 Wiring for the light points with following size PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in existing concealed or surface mounted 25 mm dia 16 gaugeMS black enamelled Conduit including wire connectors complete in all respect. 2 x 2.5sq.mm +1 x 2.5sq.mm (DB to Keypad switch) 117 2 x 2.5sq.mm +1 x 2.5sq.mm (DB to switch board) 118 2 x 1.5sq.mm + 1 x 1.5 sq.mm(Switch board to Light First Point) 119 2 x 2.5sq.mm +1 x 2.5sq.mm(2way Switch board to 2way Switch board) 120 Wiring for the power points with following size PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in existing concealed or surface mounted 25 mm dia 16 gaugeMS Conduit complete in all respect. (for power points) 2 x 4.0sq.mm +1 x 4.0 sq.mm (DB to 16A socket) 121 2 x 4.0sq.mm +1 x 4.0 sq.mm (16A to 16A socket) 122 2 x 2.5sq.mm +1 x 2.5 sq.mm (16A to 6A socket) 123 2 x 2.5sq.mm +1 x 2.5 sq.mm(DB to 6A socket) 124 2 x 2.5sq.mm +1 x 2.5 sq.mm(6A to 6A socket) 125 2 x 6.0sq.mm +1 x 6.0 sq.mm (DB to 25A socket) 126 Supply & fixing of following size/module GI Box along with modular base & cover plate for modular switch sockets as required. 1/2MODULE BOX 127 3 MODULE BOX 128 4 MODULE BOX 129 6 MODULE BOX 130 8 MODULE BOX 131 Supplying & fixing of following modular switch, socket on existing modular cover plate & switch box including connection but excluding modular plate etc. as required. 16A SP SOCKET 132 16A SP SWITCH 133 32A SP SWITCH 134 25A SP SOCKET 135 USB 136 Supply,Shifting, storing, Installation, testing & Commissioning of the following lighting fixtures with all fixing accessories etc. as required.28WATT LED LIGHT 137 32 WATT PANEL LIGHT 138 9 WATT LED DOWN LIGHTER 139 7 WATT LED DOWN LIGHTER 140 36 WATT (600X600) LED LIGHT FIXTURE 141 WALL WASHER LIGHT 142 READING LIGHT(3WATT) 143 FLOOR LAMP 144 NIGHT LIGHT POINT 145 MIRROR LIGHT (5WATT) 146 WALL BRACKET LIGHT-A(3 WATT) 147 BOUNDRY BRACKET LIGHT 148 LED COVE LIGHT 149 Supply and fixing of following sizes perforated type Hot dipped GI cable trays including support, nut bolts, bend, tee, reducers etc. & hanging arrangement as required. Thickness of Cable Tray upto size 300mm-1.6mm thicknessThickness of Cable Tray above 300mm - 2mm thickness50X50MM 150 75X50MM 151 100X50MM 152 150X50MM 153 200X50MM 154 Supplying , laying & Commissioning of following 1100 volt grade XLPE insulated PVC sheathed aluminium /copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped includes anchor fasteners wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. 3.5CX120 Sqmm Al.. Ar. XLPE cable 155 3.5CX150 Sqmm Al.. Ar. XLPE cable 156 Cable end termination of the following XLPE insulatedPVC sheathed aluminium / copper conductor armoured cables of 1100 volt grade including supplying and fixing of crimping aluminium/copper lugs, double compression glands with earthing facility at both ends of cables etc. complete as required. 3.5CX120 Sqmm Al.. Ar. XLPE cable 157 3.5CX150 Sqmm Al.. Ar. XLPE cable 158 DISTRIBUTION BOARD Supply, unloading, shifting, installation, testing & commissioningof following Distribution Boards with IP 42 along with copper bus-bar, neutral links and earth terminals all enclosed in MS box complete with hinges, metal covers, interconnections bonding to earth:- Make : Schneider / Legrand RDB-1 First & SecondDB (12 WAY SPN DB) 159 LPDB-1PANEL ROOM (8WAY TPN DB ) Incomer- 1 No.40A 4P MCB (10KA ) 3 No. 40A DP RCCB 30mA at each incomer Outgoing- 7 Nos. 16A DP MCB (10KA) 160 LPDB-2(12WAY TPN DB ) Incomer- 1 No.40A 4P MCB (10KA ) 3 No. 40A DP RCCB 30mA at each incomer Outgoing- 16 Nos. 16A DP MCB (10KA) 14 Nos. 6A SP MCB (10KA) 161 Supply, installation, testing and commissioning of flush / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shall / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shallDust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover should be provided to protect jack wiring. Quoted priceshall be inclusive of 1.6 mm thick GI Boxes. Single outlet faceplate with RJ-45 jack 162 Supply, Laying, of Cat-6 cables in existing conduit. 163 Single outlet faceplate with RJ-11 jack 164 Supply, Laying, of Cat-6 cables in existing conduit. 165 Supply and fixing ofPVC conduits in following sizes including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware. 25 mm Dia PVC Conduit 1.6 mm wall thickness. 166 LV side works (WIFI ) Containment Only Supply, installation, testing and commissioning of flush / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shall / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shallDust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover should be provided to protect jack wiring. Quoted priceshall be inclusive of 1.6 mm thick GI Boxes. Single outlet faceplate with RJ-45 jack 167 Supply, Laying, of Cat-6 cables in existing conduit. 168 LV side works (TV ) Containment Only Supply, installation, testing and commissioning of flush / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shall / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shallDust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover should be provided to protect jack wiring. Quoted priceshall be inclusive of 1.6 mm thick GI Boxes. Single outlet faceplate with RJ-45 jack 169 Supply, Laying, of CO-AXIAL cables in existing conduit. 170 Cameras Dome Fixed lens camera 2 MP - Supply, Installation, Testing & Commissioning ofIP Network TDN Low-Light IR Dome Camera, 1/2.7 CMOS, 2 MP @ 25fps or better, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 × 1080, 2.8 mm lens, BLC, HLC, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 15m IR distance, inbuilt mic , Audio support, 128GB SD card support, PoE, IP66, IK10 H.265, PoE Class 3 and 12V DC, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. 171 Bullet camera 2 MP - Supply, Installation, Testing & Commissioning ofIP Network TDN Low-Light IR Dome Camera, 1/2.7 CMOS, 2 MP @ 25fps or better, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 × 1080, 2.8 mm lens, BLC, HLC, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 15m IR distance, inbuilt mic , Audio support, 128GB SD card support, PoE, IP66, IK10 H.265, PoE Class 3 and 12V DC, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. 172 Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Vedio Recorder), for recording upto 64CH @ 1080P with 08 nos. SATA HDDs minimum 64TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 30 days),H.265/H.264/MJPEG/MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone; iPad; Android based Mobile clients, Video Export feature on USB, Search Mode: Time/Date; Alarm; Motion Detection (MD); Exact Search (accurate to a second); Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (6 nos.), 16 POE Ports,eSATA Device, 320Mbps each Incoiming & Outgping throughput, Operating Temperature –10°C to 55°CCertification : CE, FCC & UL including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. 173 Supply, installation & testing of 12 Port Layer 2 POE switchwith 12 Port LIU. 174 Supply, installation & testing of 32 Monitor Screen complete as required. 175 Supply, installation & testing of CAT-6 cable with all termination, crimping etc. 176 Supply, installation & testing of 25mm PVC FRLS1.6mm thick Conduit. 177 UPS SYSTEM Supply, storing, shifting to location of installation, installation, testing & commissioning of following ratings UPS as per Specification, Technical Data sheet & IS. 178 Supply, Installation, Testing and Commissioning of (3 phase, 4 wire IN & 3 phase, 4 wire OUT) 7.5KVA online UPS system suitable for input and output parameters strictly as per specifications with built in isolation transformer. The UPS shall be provided in powder coated fan cooled enclosure painted in colour as per specifications. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode.The system be expandable in such a manner that addition of another UPS of similar capacity can double the system output with common by-pass. The UPS shall have a microprocessor based display and control panel.UPS shall have enclosed batteries with rack, having 30 minute back-up.Make: APC / Numeric-Legrand / Emerson Input voltage : 380V to 480V,3ph+N+PE±10% Output voltage : 415 V,3 phase ±2% Battery charger Auto / Manual float cum Boost .The rate shall include overvoltage cut-off , undervoltage trip. 30 KVA Online UPS System with 30 minutes battery back-up. 179 PUBLIC ADDRESS SYSTEMSupplying, installing, testing and commissioning of 1.5W ceiling mounted type speakers with multi-tapping capable to produce minimum sound level of 75db at 3m distance. (Ceiling Speakers) 180 Supply, installing, testing and commissioning of 2c x1.5 sq. mm, PVC insulated FRLS copper armoured cable (screen shielded) confirming to IS standards and specifications. Complete as required as per technical specification. 181 25 mm Dia recessed PVC FRLS conduit to be used for Speakers for better connectivity and terminations to all speakers 182 LT Panels Supply , installation, testing & commissioning of Main LT panel/ Capacitor Panel/ Main distribution panels/ sub- distribution panelsfabricated out of 2 mm thickCRCA sheet steel in cubicle formation, compartmentalized, from 3b construction, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and/ or flats wherever necessary. 1.6 mm thick CRCA sheet steel shall be used for final distribution panels. 3 mm thick cable gland plates shall be provided on top as well as at the bottom ofthe panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 No. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire,50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings beforefabrication. Panel shall be with IP-55 protection. MAIN LT PANEL ( FOR DETAIL REFER ELETRICAL SLD) 183 CAPACITOR PANEL ( FOR DETAIL REFER ELETRICAL SLD) 184 HVAC PANEL ( FOR DETAIL REFER ELETRICAL SLD) 185 GROUND FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 186 FIRST FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 187 SECOND FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 188 TERRACE FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 189 PLUMBING PANEL( FOR DETAIL REFER ELETRICAL SLD) 190 UPS PANEL( FOR DETAIL REFER ELETRICAL SLD) 191 DG SET (100 KVA DG) Supplying, installation, testing and commissioning of silent type DG set, AMF panel, bus ducting/cable for DG sets to essentials panels synchronizing panel where required, DG sets enclouser room sound insulation/ventilation/smoke exhaust as required, earthing of DG sets system, control cabling, fule tank/piping, DG sets exhaust piping/exhaust chimney as per CPCB norms, Civil work connected with DG sets including foundation as required. 192 HT CABLES The rates under this section shall also include the following: Providing and fixing approved cable supports and grouting the same as required. Effecting proper connections at terminations. Providing all, fixing accessories such as clamping devices, nuts and bolts etc. Clamping to supports where laid in trenches. Providing proper supports for cable terminals as called for. Wherever cables cross walls provide proper sleeves at the time of civil work. Supplying , laying & commissioning of11 KV grade XLPE aluminium conductor armoured cables laid in trench. 1R x 3 C x 35 sq.mm 11 kV XLPE HT cable ( HT Metering to CSS HT Panel)(Note: Actual Length shall be checked at site) 193 Supplying and making cable end terminations for11 KV grade, XLPE aluminium conductor armoured cable including termination kit complete heat shrinkable sleeve etc. 1RX3 C x 35 sq.mm11 kV XLPE HT cable 194 PLUMBING WORK 195 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 196 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 197 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap 198 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia 199 Providing and fixing 100 mm sand cast Iron grating for gully trap. 200 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia 201 25 mm dia 202 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32mm dia 203 40mm dia 204 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end):. 32mm dia 32mm dia 205 40mm dia 206 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore 207 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore 208 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore 209 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 210 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 211 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 212 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 213 Providing and fixing 600x450 mm beveled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 214 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore 215 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm 216 Providing and fixing C.P. brass angle valve for Basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 217 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 218 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 219 Providing and fixing CP Brass Single lever wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia 220 DRAINAGE WORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 221 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 222 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 223 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 224 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 225 Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 226 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. 227 Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500D or more. 228 WATER SUPPLY WORK Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layersnot exceeding 20 cm in depth, including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 229 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329: 100 mm dia Ductile Iron Class K-9 pipes 230 150 mm dia Ductile Iron Class K-9 pipes 231 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : 100 mm diameter pipe@ 5.0mc/c 232 150 mm diameter pipe@ 5.0mc/c 233 Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class) Up to 300 mm dia 234 Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS : 13382 Up to 300 mm dia 235 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 236 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testingof joints complete as per direction of Engineer in Charge. External work 20mm nominal outer dia pipes 237 25mm nominal outer dia pipes 238 50mm nominal inner dia pipes 239 40mm nominal inner dia pipes 240 80 mm nominal dia Pipes 241 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20mm nominal bore 242 25mm nominal bore 243 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end): 25mm nomiinal bore 244 32mm nomiinal bore 245 50mm nomiinal bore 246 40mm nomiinal bore 247 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :50 mm dia 248 80 mm dia 249 Provideing and fixing C.I. Sluice Valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separtely): 100mm diameter Class II 250 150mm diameter Class II 251 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 252 SEWERAGE WORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 253 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 254 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming to IS : 4885 255 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With Sewer bricks conforming IS : 4885 256 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885 257 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With Sewer bricks conforming IS : 4885 258 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 259 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 260 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. 261 SEPTIC TANK & SOAK PIT 262 Earthwork inexcavationoverareas includingdisposalofexcavatedearth,leadupto50m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m depth 263 In all kind of soil upto 1.5m to 3.0m. depth 264 Providingandlayingofcementconcretein base excluding the cost ofcentring and shuttering by 1:2:4 (1 cement : 2 coarse sand :4 gradded stone aggregae 20mm nominal size) 265 Brick work with brick of class designation 150 infoundationandplinthincementmortar(1cement : 4 coarse sand) 266 Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Column 267 Reinforcement for R.C.C. work including, straightening, cutting bending binding andplacing in position complete. 268 Centringandshutteringincludingstruting,proping etc and removal of form for slab. 269 15mm cement plaster on rough side of mix 1:4(1 cement : 4 course sand) 270 Providing M.S.footrestincluding fixing with 20x20x10cm.cementconcrete block1:3:6(1 cement : 3 coarse sand : 6 gradded aggregate of nominalsize20mm)asperstandarddesignwith 20x20mm sq bars. 271 ProvidingandfixingC.I.teeattheinletand outlet of septic tank. 272 Providing & fixing 75mm dia vent pipes. 273 Providing&fixingof 75mmdiacastironterminal guard. 274 ProvidingandfixinginpositionprecastRCC manhole cover and frame of required shape and approved quality. M.D. -10- Circularshape 500mm internaldiameter 275 L.D. -2.5- Circular shape 450mm internaldiameter 276 Making soak pit 2.5 m diameter 3.0 metre deep with45x45cmdrybrickhoneycombshaft withbricksofclassdesignation75andS.W. drain pipe 100 mm diameter, 1.8m longcomplete as per standard design. With F.P.S. bricks 277 RAIN WATER HARVESTING 278 Earth work In excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as per as 10 sq.m on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil 279 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m. 280 Extra for every additional lift of 1.5 m or part there of in: All kinds of soil. 281 Centring and shuttering including strutting, proppintg etc. and removal of form for: Suspended floors,roofs, landings, balconies and access platform. 282 Small lintels not exceeding 1.5m clear span, moulding as in cornices, windowsills,string courses, bands, copings, bed plates, anchor blocks and the like. 283 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 284 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg/Cum 285 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in Cement mortar 1:6 (1 cement : 6sand) 286 12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand). 287 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete:200 mm diameter 288 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityL D- 2.5 Rectangular shape 600x450mm internal dimensions 289 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 Sq.M on plan) including dressing of sides and ramming ob bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, withen a lead of 50m.All kinds of soil 290 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil 291 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m. 292 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg/Cum 293 Centring and shuttering including strutting, proppintg etc. and removal of form for: Suspended floors,roofs, landings, balconies and access platform. 294 Edges of slabs and breaks in floors and walls, Under 20 cm wide 295 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.(TMT) 296 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 297 12 mm thick cement plaster of mix1:4 (1 cement : 4 fine sand). 298 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete:200 mm diameter 299 Boring/drilling bore well of required dia for Casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia. 300 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia. 301 Supplying, filling, spreading and leveling gravels of size range 5 mm to 20 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge 302 Supplying, filling, spreading and leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer-in-charge. 303 ProvidingandfixingfactorymadeprecastRCCperforateddrain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four no longitudinal and 9 nos crosssectionalT.M.T.hoopbars,includingproviding 50mmdia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mmx1.6 mm complete, all as per direction of Engineer-in-charge. 304 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 305 ProvidingandlayingbelowgroundunplasticisedPVCpipeto withstand workingpressure of4kglcm2 soildwastepipes confirmingto IS:13592 and IS:4985 includingjointing with seal ringconfirmingtoIS :5282leaving 1Ommgapforthermal expansionallnecessary fittingsetc. complete.Excavationto be paid seperataly. 160 mm diameter OD 306 Providing and fixing unplasticised PVC moulded fittings/accessoriesforunplasticisedRigidPVCsoilandwastepipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm 307 Bend 87.5° 110 mm bend 308 BOUNDARY WALL 309 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as wellas10Sqmonplan)includingdisposalof excavatedearth,lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 310 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 311 Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8(1Cement: 4coarsesand: 8gradedstoneaggregate 40mm nominal size) 312 Reinforcedcementconcreteworkinbeams,suspendedfloors,roofs havingslopeupto15°landings,balconies,shelves,chajjas,lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Beam 313 Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Footing 314 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Column 315 BrickworkwithcommonburntclayF.P.S.(nonmodular)bricksof class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarsesand) 316 HalfbrickmasonrywithcommonburntclayF.P.S.(nonmodular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 317 SteelreinforcementforR.C.C.work includingstraightening, cutting, bending,placinginpositionandbindingallcompleteuptoplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 319 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 320 Painting withsyntheticenamelpaintof approvedbrandand manufactureofrequiredcolourtogiveanevenshade.Twoormore coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture : (M.S. works). 321 Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 116.90Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 322 Providingandapplyingwhitecementbased putty of average thickness 1 mm, of approved brandandmanufacturer,overtheplastered wallsurfaceto preparethe surfaceevenand smooth complete. 323 C.C. ROAD 324 Earthworkinexcavationbymechanicalmeans (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to belevelled andneatly dressed. (D.S.R. 2.6.1) 325 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 326 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1Cement:4coarsesand:8gradedstone aggregate 40 mm nominal size) (D.S.R. 4.1.8) 327 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine 328 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. 329 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 330 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, j ointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making j oints with or without grooves (thickness of j oints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 331 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 332 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionandbindingallcompleteuptoplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.(D.S.R-5.22.6) 333 FIRE FIGHTING SYSTEM 334 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required MAKE-ALLIED ENGINEERS/MAK ENGINEERS/CPRI APPROVED INCOMING250A, 50kA4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTsetc. LED type RYB phase indicating lamps, ON, OFF, tripindicating lampsSet of CopperBus Bar 300A OUTGOING( Note : All outgoing feeders for pumps should havedigital Ammeter with selector switches, and LED typeON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fullyautomatic Star/Delta starter suitable for 60 HP pumpwith overload protection, current sensing type singlephase preventor complete with all acceessories andinternal wiring required for automatic operation,selector switch for local/remote, aut Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitableHP fully automatic Star/Delta starter with overloadprotection, current sensing type single phase preventorcomplete with all acceessories and internal wiringrequired for automatic operation, selector switch forlocal/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL Control for diesel engine comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, HighWater Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boostand trickle selector switch, 0-30 V DC volt meter, and 020 A DC Ammeter All standard relays and accessories for automatic operation of diesel engineSystem Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 335 Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air releasevalve on top and flanged connection to riser, drainarrangement with 25 mm dia gun metal wheel valvewith required accessories, pressure gauge andpaintingwith synthetic enamel paint of approved shadeas required. 336 Supply, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 150MM DIAMAKE- TYCO/MINIMAX/CEASEFIRE. (Pressure etc. to complete the system as required) 337 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel Make - NEW AGE / MINIMAX 338 Supplying and fixing first-aid 30 mtr Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. Make EWAGE/CEASEFIRE/MINIMAX 339 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Gun Metal Make NEWAGE/CEASEFIRE/MINIMAX 340 Providing and fixing Fire FHC Door 5 mm thick glass door (with M.S. frame) of size 2.1 m x 0.9 m with center opening for fire hose cabinet. Suitably marked on the outside with the letters FIRE HOSE including locking arrangement. All M.S. work to be in Red P.O. colour over appropriate primer. 341 Supply, laying, testing & commissioning of C class heavyduty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint of required shade complete as required :. Make TATA/SAIL/JINDAL 150 mm dia 342 100 mm dia 343 80 mm dia 344 50 mm dia 345 32 mm dia 346 25 mm dia 347 Providing and fixing forged brass ball valve with forged brass ball of the followingsizeincluding providing necessary union / flange. 25mm 348 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required Make CASTLE/C&R/ADVANCE/KIRLOSKAR 150 mm dia 349 100mm dia 350 80 mm dia 351 Supply, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Make : CASTLE/C&R/ADVANCE/KIRLOSKAR 150 mm dia 352 100mm dia 353 80 mm dia 354 65 mm dia 355 Supply, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.Make : DS ENGG/SANT/EMERALD 150 mm 356 100 mm 357 Providing & fixing double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required. 150mm dia 358 100mm dia 359 Supply fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories. Make Newage/Tyco/MINIMAX Pendent sprinkler 360 upright sprinkler 361 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 100 mm dia 362 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required- 4 WAY 150mm diaMake NEWAGE/CEASEFIRE/MINIMAX 363 Supplying, installation, testing & commissioning ofsprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of875 PSI (Burst) with branch line (Inlet) 25mm NPTmale thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete asrequired. For 700mm Length 364 For 1000mm Length 365 Supply and fixing of fire extinguisher, ABC Type 4.00kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 366 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 367 Supply and fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained amd locked, initially filledwith fine river sand, water as per direction of Engineer-in-charge. 368 Supplying, installation, testing & commissioningof Smoke detector complete with mounting base complete as required. 369 Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. 370 Supplying,installation,testing&commissioningresponseindicatoronsurface/ recess MS box having two LEDs metallic cover complete with all connections etc. as required. 371 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 372 Supplying, installation, testing & commissioning fire alarm sounder with facility to makeannouncement,mountedinM.S.box(16 SWG)withhingedcoverplate& suitable for operation with amplifier i/c line matching transformer etc. complete as required. 373 Supplying, installation, testing & commissioning of addresable fire control module complete as required. 374 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 375 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 376 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 377 Supplying,installation,testing&commissioningofaddressablephonecontrol module complete as required. 378 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required. 379 Supplying and drawingof cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm 380 Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 381 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protectedwith burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly onnected with the earth conductor by clamps etc.70 sq. mm 3-1/2 core 382 35 sq. mm 3-1/2 core 383 25 sq. mm 3-1/2 core 384 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 385 Supply & fixing of pressure switch in M.S. pipe line including connection etc. as required. 386 Supply & fixing flow switch in following sizes M.S. pipe including connection etc as required.-100 mm dia 387 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 388 M.S. GATE 389 Earth work in excavation by mechanical means (Hydraulic excavator)/manualmeansoverareas(exceeding30cmindepth. 1.5minwidthaswellas10Sqmonplan)includingdisposalof excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (D.S.R. 2.6.1) 390 Fillingavailableexcavated earth (excludingrock) in trenches, plinth,sidesoffoundationsetc.inlayersnotexceeding20cmin depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (D.S.R. 2.25) 391 Providing and laying in position cement concrete of specified grade excludingthecostofcenteringandshuttering-Allworkupto plinthlevel:1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size)(D.S.R. 4.1.8) 392 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plainwindowsills,staircasesandspiralstaircasesabove plinthlevel uptofloor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Beam (D.S.R 5.33.1.1) 393 Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:Raft Foundation(D.S.R 5.33.1.1) 394 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Column (D.S.R=5.33.2.1) 395 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinthlevel.Thermo-MechanicallyTreatedbarsofgradeFe-500D or more. (D.S.R. 5.22.6) 396 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) (D.S.R. 13.4.2) 397 Finishingwallswith water-proofing on cementpaint of approvedmakesuch as super snowcem,durrocem,robiacem,guttucem on undecorated wall surfaces(two coat) overone andincludingonecoatwhite cementprimertogiveaneven shade after thoroughly brushing the surface to powdered materialsincluding curing and cost of all materials.(D.S.R.-13.44.1) 398 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinthlevel.Thermo-MechanicallyTreatedbarsofgradeFe-500D or more. (D.S.R. 10.25.2) 399 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coatsonnewworkoveranundercoatofsuitableshadewith ordinary paint of approved brand and manufacture : (M.S. works). (D.S.R. 13.62.1) 400 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Uttar Pradesh View Result →
49.
Public Administrative Department #9449825 Technical Bid
Tender for the work of auditorium landscaping, HVAC and PA system in the convention center under construction in sector-8 of Ram Ganga Awasiya Yojana, 1 WALL PANELING & FALSE CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete forall heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. Make: Armstrong/ Sant GobainD.S.R. Item No. 12.52.2 2 Providing and installation of acoustical wall panelling wood finish Slats made out of MDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), backlined with black acoustical fleece, tongue-groove edge for a seamless look, FR grade, of lineal dimension size 128mm x 2440mm x 16mm thick having density 1000Kg /m3, weight12.8Kgs/m2 installed by using GI strut system. The GI strut system includes GI Cross channel having thickness 0.45mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centers. Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts both ways. Make. Armstrong / Sant GobainAs per Ref. BOQ Item No. 1.27 3 Providing and fixing in position Auditorium High Back chairs of inner side size width (W1)490X480X1020 with push back mechanism having seat assembly made of polyuret lane oam mou ded with M.S. tubular frame insert which is upholstered with fabric. The structural should be as per technical specification as mentioned below :- Back :- Back of chair shall be 470mmX730mmX130mm upholstered constructed with 19mm thick ply having proper curvature for lumber support with PIT. moulded foam having density 40±51:g/cum, upholstered chair back to have plastic back shall duly embossed, bend and Formed by ABS. The back of chair should have provision of seat number and same will be provided by the chair supplier. Seat Chair seat size to be 480X490 with thickness of minimum 130mm with 19mm plywood this should be covered with minimum 120mm in P.U. foam, fully upholstered with P.U. moulded foam having density 45±5kg/cum.Side panels :- All side panel to be of 12mm thick plywood covered with fabric and fused with 25mm thick loam, side panel to cover all exposed metal part. The end panel of row should have provision of row number indicator with LED light. Arm rest:- 2nd class teak wood melamine Polished arm rest of size 425X.65X40mm of approved design will be fixed above side panels. Fabric :- The Fabric shall be inherent Fire Resistant Fabric, 100% Polyester Stretchable Circular knit. Fabric, of approved make , shade and design of minimum 400 GSM, quilted with foam bonded fabric of 5.0mm thick. (The shade and quality is to be finalized by Engineer-in-charge as well as by the client department.)Push back :- (A) 1. A metal sheet mechanism duly embossed of size 450X440X1.6mm. 2. Block to be 2 triangular blocks duly embossed — 300X300mm with 4 of 9mm holes. . 3. Longitudinal tubes of size 40x20x490 mm of 1.6mm thickness- with 2 tubes each and 4 longitudinal tube of size 20x6 mm duly bent in shape to shape Riveted/Welded & approximately 350 mm long. 4. Seal back Bracket interconnected/Riveted/Welded and Back Bracket to be 200X60X1.6mm. 5. Seat Bracket to have stopper cup with 5 rivets and approximately 170X340X1.5mm — 2pairs for Seat/Back. 6. All rivets to be with nylon washers and pneumatic machine only. 7. Rollers to withstand temperatures up to 200 degree and oi sizes 22mm width & 38mm Dia, duly riveted and welded supported by metal sheet of size 30mmX120mm- I Pair. 8. All stopper material to be reinforced by nylon tubes of size 30mm. 9. Metal stand to be 300X300X3mm duly bent in 1 piece supported by 3 structures 20X40X270mm each. (B ) All exposed Metal parts shall be Powder Coated with 7 Tank process of minimum 50 Microns. Rigid PVC civic shall be used to hide all dashfasteners withy Nut bolts used in chair. The chair shall be installed using suitable anchor fasteners. The sample of chair shall be got approved from Engineer-incharge as well as by client department also before making mass production. (Nu additional time shall he given for this activity.) Any minor rectification/changes in above nomenclature of auditorium chair as required by Engineer-in-charge as well as client department, the same will be accepted and adopted for execution at site of work which includes in the rate of above item. Nothing extra will be paid on this account.acceptable Make : Godrej, Mars Slider High Back W/o Desklet with PU Armtop Azure Blue Main Chair Make: Godrej Interio Market Rate 4 Providing and fixing in Auditorium Flooring and Steps - Woven vinyl carpet floorings of vinyl woven series with roll dimensions of 1.8/2mtr meters width and length of 20 meters or Tiles size as per company standard should be approved by architect. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding. This work will be inclusive of all Labour, Raw Material, Hardware, adhesive etc. complete. Carpet will be provided as per approved shade and colour in Approved Makes- Vibrant Floors/Armstrong Flooring/MAC ,as per the satisfaction of the Architect and Engg. Incharge.Market Rate 5 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.D.S.R electrical Item No. 1.35make:Schneider/Northwest 6 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. make:Schneider/NorthwestD.S.R electrical Item No. 1.49 7 Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.D.S.R electrical Item No. 14.15 8 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.D.S.R electrical Item No. 19.1make: Bajaj/Havells/Crompton 9 2 thick Slotted Wood Finish Wall Panel system on Masonry: Providing and fixing wall panelling on existing masonry with 50mm x 50mm Aluminium section framework of size 600mmx600mm grids and filled with acoustical insulation of 50 mm thickness 1000 gsm density from Star Insulation or Prime Insulation. The framework and acoustical infill is to be concealed behind the 15mm Slotted finish fire rated wood finish MDF panels from Topakustik, Wood Fit, Armstrong, Sound Slats, RPG or equivalent approved vendors. The perforated wood finish panels must have a minimum perforation area of 12% or higher and is to be supplied with black RP Tissue or equivalent of approved quality. This should be completed as per details and diagrams provided. Rate shall be inclusive of installation on the frame work arrangements. Works will be inclusive of scaffolding and staging at all levels. Rate shall include the preparation of detailed shop drawings as per site conditions, which shall be approved beforecommencement of worksMake : Armstrong/ Saint GobainAs per Ref. BOQ Item No. 1.26 10 ACOUSTIC DOOR WITH CHOWKHAT FOR DOOR OPENING SIZE 1.50M X 2.1M:Providing, Supplying, Installation, Testing and fixing in position a 65 mm thick acoustic door with chowkhat. Door should have a 150 mm x 300 mm vision panel of6.0 mm thick toughened glass. Both Shutters shall be made with 100mm x 50mm thick hardwood outer frame with 50 mm x 50 mm hardwood ribs at 500 mm c/cbothways. All woodwork shall be treated with anti-termite treatment. The door shutter shall have 6 mm thick BWP grade plywood fixed on its both sides. All the cavities inside the door shall be filled with high NRC acoustic insulation materials (rockwook of 60 kg/m3 density) Insides of the door will be lined with 3mm thick MLV Sheet of minimum 1700 kg/m3 density. Periphery of the the shutter shall be covered with 12mm thick teakwood lipping matching with the door frame. The external faces of the door shutter will be finished with 1mm thick laminate on both sides. Teakwood lipping will be melamine polished. Weather seal of Rehau make shall be fixed on the door frame to fill the gap of shutter and wooden frame. Drop down seal to be fixed in shutter to block the gap with floor when the door is closed. The cost shall include all hardware fittings like heavy duty SS Hinges ( 4inch long - 5 per door) , 1ft long D type SS 304 Handles of Godrej/Hettich/Dorma make ( both inside and outside).Make: GodrejAs per Ref. BOQ Item No. 1.19 11 Providing and fixing Godrej Kaditala 275 mm ChromeMake: GodrejAs per Ref. BOQ Item No. 1.20 12 Providing and fixing hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, for door weight upto 80 kg to 100 kg and door width from 750 mm to 900 mm), with double speed adjustment with necessary accessories and screws etc. complete.Make: GodrejAs per Ref. BOQ Item No. 1.21 13 Providing and Supplying factory made Podium table 8ft long x 2ft deep x 2.5ft high made with 25mm thick prelaminated HDF Board (all full round edges) with full Vanity panel on three sides and 3 internal vertical division panels of 1ft x 2.5ft for seating 3 persons on the TABLE. The design and color of the table will be as approved by the authorities.The table will have provision for fixing electrical points.The table will have provision for 8 Way LEGRAND POP-UP Box forDATA/HDMI/ELEC. points. Make : Legrand/SchneiderAs per Ref. BOQ Item No. 3.02 14 Providing and Supplying Podium Chairs ( Mid Back without wheels) of design and color approved by college authorities Make: Godrej/ Featherlite/ Geeken/ Durian MakeAs per Ref. BOQ Item No. 3.03 15 Providing and Fixing PVC Wall Paneling with all complete fitting Make : Armstrong/GyprocMarket Rate 16 Supplying of following LED fitting on recess/surface made of metallic CRCA powder coated steel / aluminium body, minimum system efficacy 100 Lumens/watt. Electronic in buit driver, PF>0.9, suitable for 220V-240V 50Hz A.C. supply, in the existing false ceiling with S.S. chain hanging arrangements/ on surface as per site condition including making connections with 3x1.5sq.mm FRLS copper conductor cable in steel flexible pipe, testing and commissioning etc. required.SITC of Step light Colour: Anthracite grey Material Aluminum Dimensions 201 x 91 x 35 Lamp Base LED IntegratedWattage 5W ( (Equivalent to Philips Model No. B07LH1FXLR)As per Ref. BOQ Item No. 2.26 17 Supplying of following dimmable LED fitting on recess/surface made of metallic CRCA powder coated steel / aluminium body, minimum system efficacy 100 Lumens/watt. Electronic in buit driver, PF>0.9, suitable for 220V-240V 50Hz A.C. supply, in the existing false ceiling with S.S. chain hanging arrangements/ on surface as per site condition including making connections with 3x1.5sq.mm FRLS copper conductor cable in steel flexible pipe, testing and commissioning etc. required. SITC of Recessed mounted 24 watt LED down lighter made up of high pressure die cast aluminium housing complete as required. (Equivalent to Lighting Technologies,MAke : Philips,Bajaj ) As per Ref. BOQ Item No. 2.25 18 Supplying of following LED fitting on recess/surface made of metallic CRCA powder coated steel / aluminium body, minimum system efficacy 100 Lumens/watt. Electronic in buit driver, PF>0.9, suitable for 220V-240V 50Hz A.C. supply, in the existing false ceiling with S.S. chain hanging arrangements/ on surface as per site condition including making connections with 3x1.5sq.mm FRLS copper conductor cable in steel flexible pipe, testing and commissioning etc. required. Supply of 1200 mm long 20 watt LED luminiare (Make : Philips,Bajaj, Havelles LUMILINEPLUSBS20WLED865SPCSS)As per Ref. BOQ Item No. 2.27 19 Installation, Testing and Commissioning of BAJAJ single LED Signage BESL 03 LED SSD WBB GREEN above the exit doors of the auditorium including providing fixing neccassry base plate , point wiring, fitting fixture etc. complete.MAke : Philips/Bajaj As per Ref. BOQ Item No. 2.28 20 Supply installation testing of LEGRAND 8 WAY Conference Table POP UP BOX, with power , Lan , HDMI, Audio ,CGA & USB including all necessary associated hardware . Make : Legrand/SchneiderAs per Ref. BOQ Item No. 2.29 21 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).2.1 (dsr hort. 2020) 22 Supplying and stacking of good earth at site including royalty and carriageupto 5 km lead complete (earth measured in stacks will be reduced by20% for payment).2.2 (dsr hort. 2020) 23 Supplying and stacking sludge at site including royalty and carriage upto 5km lead complete (sludge measured in stacks will be reduced by 8% forpayment).2.3 (dsr hort. 2020) 24 Supplying and stacking at site dump manure from approved source,including carriage upto 5 km lead complete (manure measured in stackswill be reduced by 8% for payment) :2.4.1 (dsr hort. 2020) Screened through sieve of I.S. designation 20 mm 25 Supply & plantation of Trees upto 8ft to 10ft height well settled, all indigenous varieties (local) as per listed below, location and quantities shall be as per drawingMangifera Indica (Mango), Bacopa Monnieri (Brahmi), Terminalia Tomentosa (Asna), Azadirachta Indica (Neem) & Bambusa Bambos (Baans)Terminalia Arjuna (Arjun), Tectoria Grandis (Sagaun), Shorea Robusta (Saal), Stereospermum Tetragonum (Padal), Anogeissus Latifolia (Bakli), Madhuca Longifolia (Mahua) & Diospyros Malabarica (Gaub) Saraca asoca (ashok), Ficus religiosa (peepal), Ficus benghalensis (bargad), Aegle marmelos (bel) & Phyllanthus emblica (aonla) Pterocarpus Santalinus (rakta chandan), Butea monosperma (dhaak), Artocarpus altilis (kathal) & Santalum album (chandan) Saraca Asoka (Sita Ashok), True Cinnamon (Nag Kesar), Mangolia Champaca (Champa) & Mimusops Elengi (Maulsari) Saussurea Ggossypiphora (Mratyusanjeevani), Azadirachta Indiac (Neem) & Adiantum Venustum (Hansraj) 26 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted [email protected] litresolutionpersqmlawnorbedarea. (two application) i/c cost of chemical) and as per direction of officer-in-charge.and as per directionof officer-in-charge.2.56 (dsr hort. 2020) 27 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.2.33 (dsr hort. 2020) 28 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 2.13(dsr hort. 2020) 29 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).2.25 (dsr hort. 2020) 30 Providing and stacking of plant Mogra of height 25 to 30 cm., 2 to 3 branch in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. 4.88(dsr hort. 2020) 31 Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge. 4.91(dsr hort. 2020) 32 Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 5.13(dsr hort. 2020) 33 Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge. 5.17(dsr hort. 2020) 34 Providing and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy ,in 35 cm Cement Pot as per direction of the officer-in-charge. 5.28(dsr hort. 2020) 35 Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.1 (dsr hort. 2020) 36 Providing and stacking of Asparagus marrie, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.3 (dsr hort. 2020) 37 Providing and stacking of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.10 (dsr hort. 2020) 38 Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.6.14 (dsr hort. 2020) 39 Providing and stacking of Ophiopogon jaburan (variegated) ,full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 6.21 (dsr hort. 2020) 40 Providing and stacking of Alstonia scholaris of height 150-165 cm. in bagof size 25 cm as per direction of the officer-in-charge. 7.4 (dsr hort. 2020) 41 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.8 (dsr hort. 2020) 42 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.7.13 (dsr hort. 2020) 43 Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.17(dsr hort. 2020) 44 Providing and stacking of lotus flower of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. Mr 45 Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.2(dsr hort. 2020) 46 Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.8.7(dsr hort. 2020) 47 Providing and stacking of Cassia laevigata of height 45-60 cm. in earthenpots of size 20 cm as per direction of the officer-in-charge. 8.11(dsr hort. 2020) 48 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.14(dsr hort. 2020) 49 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 8.54(dsr hort. 2020) 50 Providing and stacking of Allamanda violacea of height 30 cm to 45 cm. in poly bag of size 20 cm as per direction of the officer-in-charge. 9.2(dsr hort. 2020) 51 Providing and stacking of Clerodendrum thomsoniae of height 30 cm.to 45 cm in 20 cm size of poly bag & as per direction of the officer-in-charge.9.6(dsr hort. 2020) 52 Providing and stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 9.14(dsr hort. 2020) 53 Providing and Stacking of Anjeer of height 75-90 cm. in poly bagsof size 25 cm as perdirection of the officer-in-charge. 11.1(dsr hort. 2020) 54 Providing and Stacking of Satavari, well developed in earthen pot of size 20 cm as per direction of theofficer-in-charge. 11.6(dsr hort. 2020) 55 Providing and Stacking of Sarpgandha well developed in poly bag of size 20 cm as per direction of theofficer-in-charge.11.14(dsr hort. 2020) 56 Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge.11.17(dsr hort. 2020) 57 Providing and Stacking of Aprajita White well developed in poly bag of size 20 cm as per direction of the officer-in-charge.11.18(dsr hort. 2020) 58 IRRIGATION SYSTEMDRIP IRRIGATION SYSTEM FOR PLANTATION - ASYSTEM HEAD UNIT SNAD FILTER + BACKWASH ASSLY 2.5Make : Astral/FinolexP.S. 59 SCREEN FILTER 2.5Make : Astral/FinolexP.S. 60 ASSLY FOR FILTER 2.5Make : Astral/FinolexP.S. 61 PRESSURE GAUGE + STOP COCKMake : Astral/FinolexP.S. 62 PRV Make : Astral/FinolexP.S. 63 NRV Make : Astral/FinolexP.S. 64 NETWORK- FINOLEX HDPE & PVC PIPESMake : Astral/FinolexHDPE PIPE 75 MM PN4 (TANK TO PLOT)P.S. 65 PVC PIPE 75 MM 4KG/CM2Make : Astral/FinolexP.S. 66 PVC PIPE 63 MM 4KG/CM2Make : Astral/FinolexP.S. 67 EMITTING SYSTEMMake : Astral/FinolexFINOGOL PLAIN LATERAL 16 MMP.S. 68 DRIPPER 8 LPH Make : Astral/FinolexP.S. 69 START TO END SET FOR DRIP LINE 16 MMMake : Astral/FinolexP.S. 70 BARBED COUPLER 16 MMMake : Astral/FinolexP.S. 71 TEE 16 MMMake : Astral/FinolexP.S. 72 ELBOW 16 MMMake : Astral/FinolexP.S.. 73 ELBOW 16 MMMake : Astral/FinolexP.S.. 74 BALL VALVE 63 MMMake : Astral/FinolexP.S. 75 FLUSH VALVE 63 MMMake : Astral/FinolexP.S. 76 VALVE BOX 12Make : Astral/FinolexP.S. 77 Pump: Crompton Greaves 10.00 Hp pumpwith necessary accessories.(Market Rate) P.S. 78 Providing and fixing H.D.P. container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destinatin hoisting and fixing of accessories such as inlet,outlet over flow of all tanks capacity above 1000 to 20,000 litresMake : Astral/FinolexD.S.R. 18.48 79 Water tank platform& ShedExcavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. By Manual Means. (with prior permission of S.E.)D.S.R. Item No. 2.2.1) 80 Providing & laying cement concrete1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)D.S.R. Item No. 4.1.8 81 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)D.S.R. 4.20.1.2 82 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)D.S.R.4.20.1.3 83 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.D.S.R. Item No. 5.22.1 84 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)D.S.R. 7.1.1 85 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)D.S.R. 7.2.1 86 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :13.33.1 Flush/ Ruled pointing sqm 87 Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.SHS 60x60x3 Column (5.34Kg/mtr)ISA 40X40X3 (1.83 Kg/mtr)Cleat ( 35X35X3)Base Plate ( 200x200x6)(7850 Kg/Cum)Top Plate ( 200x200x6)D.S.R. 10.20 88 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),D.S.R. Item No. 12.1.1 89 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete asrequired. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.1 (Electrical) 90 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.2 (Electrical) 91 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.3 (Electrical) 92 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.4 (Electrical) 93 Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.5 (Electrical) 94 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt ACsupply complete as required. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.6 (Electrical) 95 Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.7 (Electrical) 96 Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.8 (Electrical) 97 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.Make: Bose/D&B AudiotechnikD.S.R. Item No. 17.3.9 (Electrical) 98 Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm).Make : Astral/FinolexD.S.R. Item No. 17.4.1 (Electrical) 99 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.D.S.R. Item No. 17.5.1 (Electrical) 100 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.D.S.R. Item No. 17.5.2 (Electrical) 101 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessedsteel conduit of following pairs, cores and size including connections and interconnections etc. as required.Speaker cable Single pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.1 (Electrical) 102 Speaker cable Two pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.2 (Electrical) 103 Speaker cable Three pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.3 (Electrical) 104 Speaker cable Four pair, 2-core, 1.5 sqmmD.S.R. Item No. 17.5.3.4 (Electrical) 105 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupleretc. as required.D.S.R. Item No. 17.5.4 (Electrical) 106 AUDIO , VIDEO & LIGHTING WORKSSITC of Main FOH speaker having 12 inch woofer or better, min. 1.5-inch Compression driver ; Frequency Response : 82Hz-18kHz or better; Nominal Dispersion : 90° H x 60° V or better ; Power handling capacity : 250W or better; Nominal Impedance : 8O; Max SPL: 125 dB or better; Polyproylene enclosure, powder-coated finish; complete with all standard accessories as required.Make: Philips, Sony or JVRRate as per Ref. BOQ Item No. 6.01 107 SITC of Mounting/ Hanging arrangement of speaker complete with all standard accessories as required. Heavy duty Powder coated MS frame /Bracket fixed with SS Dash Fasteners of HILTI / FISHER MakeMake: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.02 108 SITC of Active Subwoofer having 18 single driver; Frequency Response : 47Hz- 105Hz or better; Max SPL (Peak) : 132dB or better; Power handing capacity : 1200W or better; complete with all standard accessories as requiredMake:Philips, Sony or JVRRate as per Ref. BOQ Item No. 6.03 109 SITC of Active Stage Monitor Speaker System having 12 single driver; Frequency Response : 65Hz - 18kHz orbetter; Max SPL (Peak) : 126dB or better; Power handingcapacity : 1000W or better; complete with all standardaccessories as required.Make: Philips, Sony or JVRRate as per Ref. BOQ Item No. 6.04 110 SITC of Dual-channel professional amplifier with 2 inputchannel, should have power output of 2x 350W @8O and2 x 660W @4O or better; Should have power outputBridged mode 2000W @4O Should have Frequencyresponse: 10Hz- 21kHz or better; Total harmonicdistortion (THD): =0.05% or better; Channelsperation(Crosstalk): = -80 dB or better, S/N ratio >104dB or better, Built-in DSP feature complete with allstandard accessories as required. (Dynacord/Bose/Powersoft)Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.05 111 SITC of Loudspeaker Management System 2 x 6 loudspeaker management system having 2x line inputs, 6x balanced outputs, input impedance > 50k O or better, CMRR: >45dB or better, Max. output level +22dBu or better, A/D performance Dynamic range >112dB Aweighted and D/A performance- Dynamic range 110dB Un- weighted or better complete with standard accessories as required.Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.06 112 SITC of 16 channel analog mixer with 8 mic/line input or better & 2 stereo output or better; 2 or better group buses; 3 or better AUX / FX send, Frequency response : 20Hz- 20kHz or better; Phantom power : 48V or better; THD : 0.03% or better; complete with all standard accessories.Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.07 113 SITC of Wireless Handheld microphone with Frequency response : 60Hz - 14kHz or better; Bandwidth: 24MHz; Total harmonic distortion (THD) : < 0.9%; Signal to noise ratio : > 103 dB; Pattern : Cardioid; Microphone type: dynamic; RF Power : 10mW or better; Operating time : 8 hours or better complete with all standard accessories.Make: Bose/D&B AudiotechnikRate as per Ref. BOQ Item No. 6.08 114 SITC of Wireless Lavalier microphone with Frequency response : 60Hz - 14kHz or better; Bandwidth: 24MHz; Total harmonic distortion (THD) : < 0.9%; Signal to noise ratio : > 103 dB; Pattern : Omnidirectional; Microphone type: Condenser; RF Power :10mW or better; Operating time : 8 hours or better complete with all standard accessories. Make: Bose/D&B Audiotechnik(Shure /Sennheiser/ Clock Audio / ElectroVoice)Rate as per Ref. BOQ Item No. 6.09 115 SITC of Wired handheld microphone with Frequency response : 50Hz - 16kHz or better; Pattern : Cardioid; Microphone type: Dynamic; Rugged metal housing; Sensitivity : 2.7mV/Pa or better, complete with all standard accessories. Make: Bose/D&B Audiotechnik(Shure /Sennheiser/ Clock Audio / ElectroVoice)Rate as per Ref. BOQ Item No. 6.10 116 SITC of CD player complete with all standard accessories(Gemini/LG/Panasonic/Sony)Rate as per Ref. BOQ Item No. 6.11 117 SITC of 4 Point XLR Junction Box complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.12 118 SITC of 2 core 2.5 sqmm Speaker Cable complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.13 119 SITC of 2 core PVC insulated Microphone Cable complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.14 120 SITC of Connector & Patch Cords complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.15 121 SITC of 9U Equipment Rack for housing all rack mountable equipments with internal wiring, front glass door; heat dessipation fans; movement wheels, power distributionunits etc. complete with all standard accessoriesRate as per Ref. BOQ Item No. 6.16 122 SITC of 6000 lumens laser Projector with 0.67 DMD technology or better; Contrast ratio (Native): 2,000:1 or better; Resolution : WUXGA or better; Inputs : 2 x HDMI or better, 1 x VGA or better, 1 x HDBaseT or better, 2x Audio in, 1x Mic in, 1x Audio out(3.5mm jack). Should have Horizontal & Vertical Keystone correction ±30°; should have 10-bit color display; Control : RS232 etc. complete.Make: PanasonicRate as per Ref. BOQ Item No. 6.17 123 SITC of Mounting/hanging arrangement of Projector complete with all standardaccessories.Rate as per Ref. BOQ Item No. 6.18 124 SITC of 150 motorized projection screen with 16:10 aspect ratio complete with all standard accessories (Somfy motor)Rate as per Ref. BOQ Item No. 6.19 125 SITC of Wall Plate type transmitter & Receiver extender with 1 x HDMI or better, 1 x VGA with audio input (Tx) or better, 1 x Twisted Pair output (Tx) or better; 1 x Twisted Pair Input (Rx) or better, 1x HDMI output(Rx) or better; transmission range :70 meter or better; Auto-switching between inputs; Supports computer and video resolutions up to 4K or better; Max Data rate : 10.2 Gbps or better; HDCP 1.4 or better compliant; complete with all standard accessories.Make :Extron/Crestron/Lightware / Liberty AV)Rate as per Ref. BOQ Item No. 6.20 126 SITC of 1.8 meter HDMI-HDMI Cable complete with all standard accessories.(Make: Belden/ Kramer / Liberty AV)Rate as per Ref. BOQ Item No. 6.21 127 SITC of 1.8 meter VGA-VGA with audio Cable complete with all standard accessories.(Make: Belden/ Kramer / Liberty AV)Rate as per Ref. BOQ Item No. 6.22 128 SITC of of Twisted Pair Cable complete with all standard accessories6.23 129 SITC of 100W High Quality LED Parcan Light complete with, Lamp source 3200K CCT Colour temperature CRI & TLCI Values above 95 COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) DmX 512 dimming with 3 channel control Beam Angle of 9° / 25° / 45° Total Power Consumption of 165W High quality output replacing 1000W Halogen Par Flicker Free 100% for Tv & Film Cameras 11.7KHz Refresh Rate, Linear Dimming 0 ~ 100% Fuse and Internal safety protections Strobe option Adjustable 1~25 times/Sec Variable Fixture provided with Yoke of Manual Adjustment5 Pin XLR for DmX , Black powder coated body. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 CE Certification compliant to EN60598-1:2015,EN61437-2-13:2014 LM79 Certificates from NABL Acrediated laboratory. Brand embosed impact on the light body for genuine product.(Make: Bajaj/Leksa Lighting / Kenson Solace / Aultra Lighting / Canara)Rate as per Ref. BOQ Item No. 6.24 130 SITC of 200W LED Profile Spot 19 Degree Light complete with, 3200K CCT Colour Temperature COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) CRI & TLCI above 95, Strobe option Adjustable 1 ~ 25 times/Sec 4 Kinds of dimming curves, Black finish housing, Manual Focus with 4 Beam shaping cutters Efficient and well-designed Lamp reflector Efficient Copper tube based Heat Sink for Heat Dissipation Sleek and Unique Designed Light weight body Fixture provided with Yoke of Manual Adjustment DmX512 dimming with 1 or 3 Channel modes IP20 protection having Lux @ 3 Mtrs above 12040 suitable to illuminate the keypresentor or talent on stage. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 . CE Certificationcompliant to EN60598-1:2015, EN61437-2-13:2014 LM79 Certificates from NABL Acrediated laboratory. Brand embosed impact on the light body for genuine product (eksa Lighting / Kenson Solace / Aultra Lighting / Canara)SITC of 200W LED Profile Spot 19 Degree Light complete with, 3200K CCT ColourTemperature COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) CRI & TLCI above 95, Strobe option Adjustable 1 ~ 25 times/ Sec 4 Kinds of dimming curves, Black finish housing, Manual Focus with 4 Beam shaping cutters Efficient and well-designed Lamp reflector Efficient Copper tube based Heat Sink for Heat Dissipation Sleek and Unique Designed Light weight body Fixture provided with Yoke of Manual Adjustment DmX512 dimming with 1 or 3 Channel modes IP20 protection having Lux @ 3 Mtrs above 12040 suitable to illuminate the keypresentor or talent on stage. RDM Control options with latest technology (RDM ID to be specified)Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 . CE Certificationcompliant to EN60598-1:2015, EN61437-2-13:2014LM79 Certificates from NABL Acrediated laboratory.Brand embosed impact on the light body for genuine product(Make: Bajaj /Philips/ eksa Lighting / Kenson Solace / Aultra Lighting / Canara)Rate as per Ref. BOQ Item No. 6.25 131 SITC of 54 x 3W LED Par Light RGBW, Beam Angle 25° complete with LED source from Lumiled / Seoul / Nichia or reputed make (LM80 to be provided) (Leksa Lighting / Kenson Solace / Aultra Lighting / Canara) RGBW 3W Lamp source x 54 Pcs DmX 512 dimming with 8 Channel High Bright Red, Green, Blue, White LED’s Source Unlimited Color Mixing through DmX 0 ~ 100% Linear dimming , In built presets for different colors Strobe Mode 20 times/Sec Data DmX through 3 / 5 PinXLR’s 65dB ~ 130dB Sound sensing capacity Power In and Out Connections High precision colors, IP20 protectionPowder coated Black finish housing Having Sound Control & Master Slave Auto Run Mode Illuminate the Indoor stage with unlimited colour effects Rigidly built pressure die-casted Aluminium body.RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1):2012 CE Certification compliant to EN60598-1:2015, EN61437-2-13:2014 LM79 Certificates from NABLAcrediated laboratory. Brand embosed impact on the light body for genuine product. Make: Bajaj/PhilipsRate as per Ref. BOQ Item No. 6.26 132 SITC of Light fixture mouting clamp Customized for suspending on fixed bars on stage Made up of Aluminium Die casted MS threaded T bolt with yellow passivation finish Complete with black powder coating matt black finish. Safeworking load 150 KG Suitable to Batten of size 30 OD to 60 OD (Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara)Rate as per Ref. BOQ Item No. 6.27 133 SITC of Light Fixture dual safety Chain made up of GI wire rope Bundled and twisted together Having load bearing capacity above 200 Kgs Sleve on the rope. CarabinerClip(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.28 134 SITC of Fixed on stage Lighting bar/winch of 6 Mtr length constructed with an single contruction light bar Made out of 48mm Outer Dai, 40 Nominal Bore, Mild Steel Pip It shall be hanged from the roof to accommodate various type of stage light fittings. It should hang from the roof with MS angle which is suspended from the fish plate of 5mm thickness which is fixed on the rcc roof with 4 anchor fastners of 10mm.Each fastnerMade out of 48mm Outer Dai, 40 Nominal Bore Material for the light bar shall be of Mild Steel Pipe Dual Barrel Arrangement and an additional End Caps on the Pipe end Powder coated with Matt black Texture Fixing Through Suspenders as per site conditions.Suspender prices are included(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.29 135 SITC of Power Distribution Electrical panel having a Individual MCB control for 6 outgoing circuits Made up of MS Sheet metal fabricated housing Black powder coated Ivery connectors for the internal terminations and external outgoing connecting points, Fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Custom built as per specification and project requirement.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.30 136 SITC of High quality power junction box 4 way made up of MS Sheet metal fabricated housing. Snap fit fixing /15 (1.5mm ) Total Max Rating 10A, 250V A.C 20°C to +70°C Operating Temp Moldings: Nylon, Flammability Rating UL94V-0 Blackpowder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A. Clamp arrangement for fixing or Raul plug arrangement for wall / floorfixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.31 137 SITC of High quality power junction box 2 way made up of MS Sheet metal fabricated housing. Snap fit fixing /15 (1.5mm ), Total Max Rating 10A, 250V A.C 20°C to +70°C Operating Temp Moldings: Nylon, Flammability Rating UL94V-0 Black powder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A. Clamp arrangement for fixing or Raul plug arrangement for wall/floor fixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.32 138 SITC of High quality Dimming In junction box 1 way made up of MS Sheet metal fabricated housing High temperature resistant insulator material All metal housing offers best overall RF protection & electromagnetic shielding Black powder coated,fibre glands of suitable size fitted with 5 Pin DmX XLR Male socket Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.33 139 SITC of DmX Loop Junction Box having 1 No. of DmX 5 Pin XLR Female Socket & 1 No. DmX XLR Male Socket fitted on to a sheet metal fabricated compact Junction box powder coated with matt black texture finish paint. High temperature resistantinsulator material All metal housing offers best overall RF protection & electromagnetic shielding. Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.34 140 SITC of Internal Earthing System with copper bare conductors all along the cable trays, metal parts and Installation HardwaresRate as per Ref. BOQ Item No. 6.35 141 SITC of Black Powder coated cable trays made out of MS Sheet fabricated for a size of 40 x 75 x 40mm & 1.6 mm thickness undergone through 7 tank process with various chemical treatment to keep them rust free with perforation for heatdessipation provided with lid.Rate as per Ref. BOQ Item No. 6.36 142 SITC of DmX Male Female Connectors 5 Pin having rubber sheeth protection forCross connecting DmX wiring connections.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.37 143 SITC of DmX Male Termination Connector 5 Pin soldered with required capacity of resistor for signal deframing.(Make : Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.38 144 SITC of DmX Controller 12 Faders to control atleast 12 channels with Master control fader ,12 Set Scene saving options Master Fader Enabled Controller , LCD display access,Eeasy access key pads 12 Physical Fader unit for direct access Incremental Channel Up & Down Buttons DmX 512 protocol.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.39 145 SITC of DmX Controller 12 Faders to control atleast 12 channels with Master control fader ,12 Set Scene saving options Master Fader Enabled Controller , LCD display access,Eeasy access key pads 12 Physical Fader unit for direct access Incremental Channel Up & Down Buttons DmX 512 protocol.(Make: Leksa Lighting / Kenson Solace / Aultra Lighting / Canara )Rate as per Ref. BOQ Item No. 6.40 146 SITC of FRLS Copper unarmoured Flexible cable IS694 having 3 Core each of 1.5 Sq mm size.Rate as per Ref. BOQ Item No. 6.41 147 SITC of 5 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmit DmX signalRate as per Ref. BOQ Item No. 6.42 148 38 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X38) Make: Daikin/Mitsubishi Electric 149 36 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X36) Make: Daikin/Mitsubishi Electric 150 34 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X34) Make: Daikin/Mitsubishi Electric 151 12 HP(As per DSR_VRF/VRV _2019_1.1) (Rate=16415X12) Make: Daikin/Mitsubishi Electric 152 Indoor Unit Cassette TypeSupply, Installation, Testing & Commissioning of following minimum capacity 4-way flow VRF/VRF Cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolator, cordess remote control etc., suitable for operation on single phase 230V + 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system or fire panel of the building. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Make: Daikin/Mitsubishi Electric3.2 TR 4 Way VRV/VRF Cassette Unit(As per DSR_VRF/VRV _2019_2.8) 153 2.0 TR 4 Way VRV/VRF Cassette Unit(As per DSR_VRF/VRV _2019_2.5) Make: Daikin/Mitsubishi Electric 154 0.8TR(As per DSR_VRF/VRV _2019_3.2)Make: Daikin/Mitsubishi Electric 155 1TR(As per DSR_VRF/VRV _2019_3.3) Make: Daikin/Mitsubishi Electric 156 1.3TR(As per DSR_VRF/VRV _2019_3.4) Make: Daikin/Mitsubishi Electric 157 1.65TR(As per DSR_VRF/VRV _2019_3.6) Make: Daikin/Mitsubishi Electric 158 2.0 TR(As per DSR_VRF/VRV _2019_3.7) Make: Daikin/Mitsubishi Electric 159 Indoor Unit Ductable TypeSupply, Installation, Testing & Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V + 10%, 50Hz, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system or fire panel of the building. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Mid Static Ductable Units (Minimum 45 Pascal External Static Pressure) Make: Daikin/Mitsubishi Electric4.0 TR(As per DSR_VRF/VRV _2019_4.16) 160 High Static Ductable Units (Minimum 110 Pascal External Static Pressure) Make: Daikin/Mitsubishi Electric5.5 TR(As per DSR_VRF/VRV _2019_4.17) 161 7.1 TR(As per DSR_VRF/VRV _2019_4.18) Make: Daikin/Mitsubishi Electric 162 8.0 TR(As per DSR_VRF/VRV _2019_4.19) Make: Daikin/Mitsubishi Electric 163 4.0 TR(As per DSR_VRF/VRV _2019_4.16) Make: Daikin/Mitsubishi Electric 164 11.0 TR (Market Rate) Make: Daikin/Mitsubishi Electric 165 15.0 TR (Market Rate) Make: Daikin/Mitsubishi Electric 166 17.0 TR (Market Rate) Make: Daikin/Mitsubishi Electric 167 Supply Installation, testing & commissioningof Y-joints for various size of Refrigerant pipe including insulation. (As per MR-1)(Rate=4123/1.18) 168 Centralized controllerSupply Installation, testing & commissioningofMainIntelligenttouch screen centralcontroller systemincluding all the accessoriessuitableto operate, monitor, on/off, temperature setting of all the indoor units individually complete as required and as specified. (As per MR-2) (Rate=80703/1.18) 169 Copper Refrigerant PipingSupply, Installation, Testing & Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with with Class-O closed cell elastometric nitrile rubber insulation of specified thickness as given below for Suction and Liquid lines, exposed piping shall be protected with UV & water protective coating, all accessories as per specifications etc. as required:6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation (As per DSR_VRF/VRV _2019_5.1) 170 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.2) 171 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.3) 172 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.4) 173 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.5) 174 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.6) 175 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.8) 176 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.10) 177 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation(As per DSR_VRF/VRV _2019_5.12) 178 Drain PipingSupplying & fixing of UPVC drain piping with all fitting such as bends, tees etc. necessary clamps, adequate support duly insulate with 9 mm nitrile rubber insulation complete as per technical specifications, requirement, standardard and drawings complete as required.50 mm dia(As per MR-3)(Rate=298/1.18) 179 40 mm dia(As per MR-3) (Rate=204/1.18) 180 32 mm dia(As per MR-3) (Rate=157/1.18) 181 25 mm dia (As per MR-3) (Rate=121/1.18) 182 Inline FansSupply, Installation, testing and commissioning circular direct driven / cabinet inline fans of G.I. construction complete with centrifugal fan with motor, accoustically lined, canvass connection at inlet and outlet complete with electric panel with MCB and relays, with 5 Rm cabling and earthing complete as per standards, requirement and drawings. 3300 cfm 20 mmwg S.P(As per MR-4)(Rate=45163/1.18)Make: Daikin/Mitsubishi Electric 183 800 cfm 15 mmwg S.P(As per MR-4) (Rate=23520/1.18) Make: Daikin/Mitsubishi Electric 184 550 cfm 15 mmwg S.P(As per MR-4) (Rate=17064/1.18) Make: Daikin/Mitsubishi Electric 185 500 cfm 15 mmwg S.P(As per MR-4) (Rate=17064/1.18) Make: Daikin/Mitsubishi Electric 186 450 cfm 15 mmwg S.P(As per MR-4) (Rate=15743/1.18) Make: Daikin/Mitsubishi Electric 187 400 cfm 15 mmwg S.P(As per MR-4)(Rate=15743/1.18) Make: Daikin/Mitsubishi Electric 188 350 cfm 15 mmwg S.P(As per MR-4)(Rate=15743/1.18) Make: Daikin/Mitsubishi Electric 189 300 cfm 15 mmwg S.P(As per MR-4) (Rate=14056/1.18) Make: Daikin/Mitsubishi Electric 190 250 cfm 15 mmwg S.P(As per MR-4) (Rate=13102/1.18) Make: Daikin/Mitsubishi Electric 191 200 cfm 15 mmwg S.P(As per MR-4) (Rate=13102/1.18) Make: Daikin/Mitsubishi Electric 192 150 cfm 15 mmwg S.P(As per MR-4) (Rate=12662/1.18) Make: Daikin/Mitsubishi Electric 193 100 cfm 15 mmwg S.P(As per MR-4) (Rate=12662/1.18) Make: Daikin/Mitsubishi Electric 194 Propeller Type FanSupply, installation, testing and commissoning of propeller type fan for exhaust air complete with in and out gravity louvers, 3 pin socket with 5RM cabling complete as per specifications, requirement, standard and drawings.Make: Daikin/Mitsubishi Electric200 mm dia,5 mmwg S.P. (As per MR-5)(Rate=13039/1.18) 195 Exposed Copper Pipe CoatingSupplying and fixing of UV/fire/water, thermal protective coating, with canvas/glass fibre cloth, coating on copper pipe insulation by wrapping canvas/glass fibre cloth dipped instarbond/polybond30-36completeasperspecificationsanddrawings.(Thepriceshouldbequotedconsideringminimum3coatsof30-36chemical). (AsperMR-6) (Rate=587/1.18) 196 Packaged Type AirwasherSupply, installation, testing and commissioning of floor mounted CELLULOSE FILL AIR-WASHER complete with double skin construction fabricated out of extruded aluminium sections with 0.8 mm thick pre-plasticised GI sheet on out side and 0.8 mm thick plane GI sheet inside with 25 mm thick insulation, 40 Kg / m3 density PUF insulation in between. The unit shall comprise of supply fan sections with DIDW backward curve fans (efficiency not less than 75%) suitable for static pressure as required,belt drivepackage with TEFC drive motor of efficiency class IE3suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply, giving 95% adiabatic saturation efficiency at 500 FPM air velocity across pads, factory assembled and complete with 16 gauge GI casing for Air washer section, 18G SS-304 water tank, Cellulose fill, water distribution header, PVC piping, butterfly valves, for quick fill, isolation of tank, pumps and brass strainers, Y strainers, fire rated flexible duct connections & aluminium volume control damper at blower discharge and necessary fittings, belt drive package, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. The fan and motor shall be mounted on aluminium extruded section.The unit shall also include provision of GSS partitions duly reinforced at intake side of air washer and GSS louvers with bird-screen synthetic washable filters and four bend PVC drift eliminators and horizontal monoblock pumps of suitable rating, factory mounted on mild steel channel base with electric motor for circulation of water. Pumps shall be aligned and suitable for 415±10% volts, 50 cycles 3 phase power supply. One No. 3 phase isolator switch in weather proof enclosure shall be provided near motor complete as required confirming to specification. Make: Daikin/Mitsubishi Electric3,000 CFM, 50 mmwg Static Pressure (As per MR-7)(Rate=205427/1.18) 197 Exhaust ScrubberSupply, installation, testing & commissioning of double skin exhaust scrubber of 0.6 mm inner and outer skin construction fabricated from precoated sheet blower housing with DIDW backward curved centrifugal blower with fan motorand belt drive arrangement with totally enclosed fan cooled class F insulation, with IP 55 protection, TEFC high efficiency motor type IE-3 suitable for 415+-10% volts, 50 HZ, 3 Phase A.C. supply, all accessories like common base frame, fan, motor pulley, belts, fire proof canvass connection, vibration isolator, prefilters, wet scrubber section, spray, nozzels, filters, M.S. frame for supports etc.complete as per specifications, requirement, standardard and drawings.Make: Daikin/Mitsubishi Electric4,000 CFM, 65 mmwg Static Pressure (As per MR-8) (Rate=220100/1.18) 198 DuctingSupply, installation, balancing and commissioning of factory fabricatedGSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.G.I. Sheet Metal Ducting (Rectangular)Thickness 0.63 mm sheet (As per DSR_E&M _2022_16.12.1.1)(Rate=1080/1.12) 199 Thickness 0.80 mm sheet (As per DSR_E&M _2022_16.12.1.2)(Rate=1263/1.12) 200 Thickness 1.0 mm sheet (As per DSR_E&M _2022_16.12.1.3)(Rate=1381/1.12) 201 Thickness 1.25 mm sheet (As per DSR_E&M _2022_16.12.1.4)(Rate=1836/1.12) 202 Grilles / DiffuserSupply, installation, testing and commissioning of Aluminium extruted powder coated supplyand returnairgrilles/ diffusers as per specifications and drawings (Approval of colour shall be taken from Architects/Consultants).Supplying&fixingofpowdercoatedextrudedaluminiumSupplyAirGrillswithaluminiumvolumecontroldampersasperspecifications.(AsperDSR_E&M_2022_16.15)(Rate=9105/1.12) 203 Supplying&fixingofpowdercoatedextrudedaluminiumReturnAirGrillswithlouversbutwithoutvolumecontroldamperscompleteasrequired.(AsperDSR_E&M_2022_16.16)(Rate=5910/1.12) 204 Supply, fixing, testing & commissioning of Return air diffussers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.(As perDSR_E&M _2022_16.18)(Rate=8121/1.12) 205 LouversSupply and fixing of Fresh / Exhaust air Aluminium extruded with bird screen, damper adjustable louvers as per specifications and drawings.(As per MR-9)(Rate=12986/1.18) 206 Volume Control DamperSupply, installation,testing andcommissioning ofGIvolumecontrol duct damper completewith neoprenerubber gaskets, nuts, bolts, screws linkages,flanges etc, as per specifications. (As per DSR_E&M _2022_16.13)(Rate=7046/1.12) 207 Flexible DuctSupply of 25 mm glass wool insulated double lamination of metalize polister film parmantely bounded to a coated spring wire, helix and resistant construction of tear and pincture branch and collor where ever suitable of following sizes. Connected at both ends with necessary jublie clamps150 MM Dia(As per MR-10)(Rate=404/1.18) 208 IsolatorSupplying & installation of weather proof isolator with suitable rating near each outdoor unit and complete as required. 63 Amps(As per MR-11)(Rate=5136/1.18) 209 40 Amps(As per MR-11)(Rate=5136/1.18) 210 Control & Transmission WiringSupplying & fixing control cum transmission wiring of copper in heavy duty conduits PVC conduits between indoorand out door unit. (As per MR-12)(Rate=113/1.18) 211 Sub Panel For KitchenSupply, installation,testing & commissioning of sub panel board cubical compartmentalised, weather proof Floor/ Wall mounted made of 2.0 mm thick steel sheet duly painted completewithvoltmeter,ammeter,indicatinglightsforselectorswitch,incoming/outgoingfeeders,NO/NC contactors,CTScontactorscompleteasperspecificationsand requirement1 No. 32 Amps TPN incoming MCB1 set 40 Amps TPN Aluminium conductor bus bar duly sleeved.2 Nos. 25 Amps MCB outgoing along with 2 Nos. DOL starter for Scrubber Motor (5.5 kw) (1 No Spare). 2 Nos. 16 Amps MCB outgoing along with 2 Nos. DOL starter for Airwasher Motor (3.7 kw) (1 No Spare).3 Nos. 6 Amps SPN MCB outgoing for Airwsher & Scrubber Pump.(0.37 / 0.55 kw) (1 No. Spare).(As per MR-13)(Rate=124723/1.18) 212 Power CablingSupply & fixing of PVC sheathed Aluminium / Copper cables for various equipments through walls/ceiling with appropriate clamps & fixing arrangement as per specifications and drawings.3C - 4 sqmm (Aluminium) for Airwasher & Scrubber(As per MR-14)(Rate=126/1.18) 213 3C - 2.5 sqmm (Aluminium) for Airwasher & Scrubber pump(As per MR-14)(Rate=117/1.18) 214 4C - 16 sqmm (Copper) (As per MR-14)(Rate=1102/1.18) 215 4C - 10 sqmm (Copper) (As per MR-14)(Rate=753/1.18) 216 Cable TraySupplying and installation of following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.2)(Rate=604/1.12) 217 300 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.4)(Rate=777/1.12) 218 450 mm width X 50 mm depth X 1.6 mm thickness(As per DSR_E&M _2022_4.1.6)(Rate=1137/1.12) 219 EarthingProviding and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (As per DSR_E&M _2022_5.15)(Rate=244/1.12) 220 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.(As per DSR_E&M _2022_5.16)(Rate=70/1.12) 221 Ductable Split UnitSupplying,installation,testing & commissioning of ductable type split unit air-conditioners with evaporator with coil, fan and fan motor, aircooled condenser with hermatically sealed scroll compressor, condenser coil, propeller fans controls, mounting stand for ODU, control panel, corded remote, canvass connection as per standards, requirement and drawings.Make: Daikin/Mitsubishi Electric3.0 Tons(1 Working & 1 Standby) for Server Room(As per MR-15)(Rate=88040/1.18) 222 Refrigerant Piping (For Split)Supplying & installation copper soft/hard refrigerant piping along (Circuit length) with control cabling and earthing should be insulated with 9 mm thick pipe section of nitrile rubber complete in all respect.3.0 Tons Ductable Split Unit(As per MR-16)(Rate=1981/1.18)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
50.
Housing Urban and Rular Development #9443236 Technical Bid
Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction of Chakrateertha Kund Complex and Other Truism Development work at Naimisharanaya, District- Sitapur (U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil l (1.5m to 3.0m) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 6 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centring and shuttering including strutting,propping etc. and removal of form for 11 Foundations, footings, bases of columns etc. for mass concrete. 12 Suspended floors, roots, landings, balcnies and access platform. 13 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 14 Columns,Pillars, Piers, Abutments, Posts and Struts 15 Stairs,(excluding landings) except spiral-staircaces. 16 Weather shade,Chajjas, corbels etc. including edges 17 Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of deshutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roots, laning, beams and balconies (Plan area to be measured) 18 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement contant of 330 kg/cum All works upto plinth level 20 Concrete of M25 grade with minimum cement content of 330 kg /cum 21 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap 22 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap 23 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 26 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 27 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 28 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red 29 Area of slab upto 0.50 sqm 30 Area of Slab over 0.50sqm 31 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. 32 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 33 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 34 Providing and fixing 12 mm toughened glass partition with neccessary fittings and Applying clear silicon on joints complete in all respect. 35 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edge 37 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square. 38 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 39 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 40 Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain)toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor = 0.45, U-Value = (W/sq.m-K) 5.7W /M2K, Visible light transmittance = 0.30) 41 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 42 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock with key cylinder fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 43 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 44 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 45 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 46 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 47 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. 48 Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 49 Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 50 Providing and fixing approved brand and manufacture SS 304 grade Center Patch Lock wih Cylinder complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 51 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness 52 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 53 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 54 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 55 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 10 mm 56 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : White sand stone - exposed face fine dressed with rough backing 30 mm thick 57 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 58 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases 59 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 60 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 61 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm 62 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 63 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm 64 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 65 Providing and laying 18 mm thick leather finish steel grey granite stone flooring in required design and patterns, in linear as well as curvilinear portions in building flooring, footpath etc. all complete as per the architectural drawings with over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 66 Providing and fixing machine cut, mirror/ eggshell 18mm thick leather finish steel grey granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 67 Applying breathable, non-reactive,antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 68 Supply, fabricating, transporting, hoisting and fixing in position good quality durable Mirzapur sand stone/ any other type of sand stone in various elements for all level all height.Stone shall be free from cracks, lines, stains, white spots of efflorescence and even in shade for each elements. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with differant process ofi.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The drawings provided are vary preliminary and amount of carving will be more then what is shown on the drawings. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 69 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. White sand stone 70 Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. 71 Providing and fixing 40mm thick cladding comprising of Wooden framework using 25mx50mm sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 4mm thk. veneer on one sidepasted and pressed with adhesive to give a uniform and smooth finish, including4mm thk. S.S. strip framework on all sides of veneer panels with wooden member surround, top moldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms. No extra shall be paid for making of openings, door / window frames and for making provisions for electric conduits. etc. all complete as per direction of Engineer-in-charge. 72 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 73 Providing and fixing Granite stone gang saw cut (polished and machine cut) of thickness 18mm for wall lining, backing filled with a grout of average 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar with an admixture of pigment to match the granite shadeetc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 74 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) 75 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) 76 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) 77 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 78 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 79 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 80 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 81 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats on new work 82 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 83 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 84 Two or more coats on new work 85 Melamine polishing on wood work (one or more coat) 86 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 87 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) 88 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 89 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron) 90 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness of powder coating 50 micron) 91 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 10 mm depth and 10 mm width 92 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 93 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm 94 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 95 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 96 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 97 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab. 98 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 99 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 100 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 101 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 102 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 103 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 104 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 105 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 106 Supplying and stacking at site dump manure screening by 4.75 mm sievefrom approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : 107 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 108 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 109 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 110 Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 111 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPEbag as per direction of the officer-in-charge. 112 Providing and displaying of Dracaena margineta plant, having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 113 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e lawn trees,shrubs, hedge, flower beds,foliages,creepers etc including hoeing, weeding pruning replacement of plants, gap filling, watering,mowing of lawn,grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecting sites,pesticide and fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office in charge. (cost of good earth,menure, fertilizers, insecticide , pesticide,lawn mover and brush cutter with fuel will be provided by the department and other T/P material/articles shall be provided by the contractor. Open spaces (1Mali for 3.00 Acre). 114 Providing and fixing watercloset squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, including wall hung cistern & installation kit with duel flush fitting (2.0/4.0 lts. per flushing), conforming to IS 7231, with all fittings & fixtures complete including cutting and making good the walls and floors wherever required.( MAKE-1 : JAQUAR, MODEL NO. INDIAN WC : ECS-WHT-453LE & CISTERN : WHC-WHT-184BTTG OREQUIVALENT.) White vitreous china Orissa pattern WC pan of size 415 x 515 x 255mm . 115 Providing and fixing white vitreouschina extended wall mountedwater closet of size 350 X 545 X 380mm of approved shape including providing and fixingof concealed cistern with duel flush fitting (2.0/4.0 lts. per flushing), including sheet cover, and cistern fittings, nut bolt gasket,chair etc complete. ( MAKE-1: JAQUAR, MODEL NO. WALL MOUNTED WC : FLS-WHT-5953 & CISTERN & FACE PLATE :JCS-WHT-2400SG & JCP-CHR-152415 OREQUIVALENT.) 116 Providing and fixing white vitreous china flat back half stall urinal of size 370 x 315 x 620mm with urinal valve auto closing system (0.75 lts. per flushing) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :. ( MAKE-1: JAQUAR, MODEL NO. URINAL : URS-WHT-132530 & URINAL VALVE AUTO CLOSING :PRS-CHR-077G OREQUIVALENT.) 117 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with15 mm C.P. brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & BASIN MIXER :FLR-CHR-5001BG & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15mm CP Brass single hole basin mixer with flow rate 2.5 litre per minute at 3 bar . 118 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 119 510x1040 mm bowl depth 250 mm 120 Providing and fixing hand shower (Health faucet)with 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor withflow rate 6 litre per minute at 3 bar in chrome finish and wall hook. ( MAKE-1: JAQUAR, MODEL NO. HEALTH FAUCET : ALD-CHR-573GA OREQUIVALENT.) 121 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ( MAKE-1: JAQUAR, MODEL NO. BOTTLE TRAP : ALD-CHR-769L300X190 OREQUIVALENT.) 122 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. For physically handicap person consisting of; 123 Wall mounted WC Pan-01 no. withbuilt in Jet of Cera CAT no.S1046105 124 Concealed Cistern Cistern-01 no.of Cera CAT no. B1110108 & Knob B1120118 125 Soft Close Seat Cover -01 no of Cera CAT no.B1520106 126 Wall hung Wash Basin -01 no of Cera CAT no.S2040147 127 Spatula Single leverCera CAT no F9030451 128 Wall mounted Grab bar 600 mm long - 2 nos of Cera CAT no.B2210106 129 Wall mounted Hinged hand rail 750 x 100-01 no Cera CAT no B2210108 130 Bottle Trap Cera CAT no F8060403 131 Waste Coupling Cera CAT no F8050101 132 Stainless soap dish Cera CAT no F5007106 133 Tissue paper holder Cera CAT no F5007110 134 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete40mm Dia 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing & fixing toilet paper holder C.P. brass 137 Providing and fixingof fully automatic NO TOUCH durable & shock proof hand drier of approved make & manufacture suitable to operate on 220 volts, single phase 50 hz, A.C. power supply, 1500 Wattand directly plugged to power point complete in ABS plastic body having drying time 20-30 seconds complete as per direction of Engineer in Charge. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. 138 Providing, Fixing of CP brass Towel Rack 600mm long without hanger with 3 hooks and CP brass screws complete as required. 139 Providing & fixing glass urinal partition of Height: 900mm,Width: 450mm &Frosted Safety Glass: 8 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required. 140 Providing and fixing soil waste and vent pipesHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75 mm dia. 141 Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. 142 For 100mm dia pipe 143 Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete 144 100 mm dia 145 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 146 75 mm dia 147 Providing and fixing plain bend of required degree: 148 100 mm dia 149 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 150 75 mm dia 151 100 mm 152 SS 304 grade coupling with EPDM rubber gasket 153 75 mm 154 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 155 100mm 156 Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 157 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. 158 Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) 159 Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes) 160 Providing & fixing Nickel Chromium Platedliquid soap container/ dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. ( MAKE-1 : JAQUAR, MODEL NO. - ACN-CHR-1137N OR EQUIVALENT. 161 Providing, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RING : ACN-CHR-1121N OREQUIVALENT.) 162 Providing & fixing soap dish holder of approved design.( MAKE-1: JAQUAR, MODEL NO. SOAP DISH : ACN-CHR-1131N OREQUIVALENT.) 163 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with 15 mm C.P. brass pillar tap of auto closing type of approved quality and make with, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & PILLAR TAP :PRS-031G & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) 164 White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15 mm C.P. brass pillar tap auto closing type of approved make with flow rate 2.5 litre per minute at 3 bar . 165 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. ( MAKE-1: JAQUAR, MODEL NO. SINK MIXER : FLR-CHR-5163GD OREQUIVALENT.) 166 Providing , Fixing of CP Brass Shower Mixer with provision of overhead shower with 115mm long bend pipe, in built spout, spout/shower selector with flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. ( MAKE-1: JAQUAR, MODEL NO. SHOWER MIXER : FLR-CHR-5273UPRGD OREQUIVALENT.) 167 Providing,Fixing wall mounted Double Coat hookon door complete. ( MAKE-1: JAQUAR, MODEL NO. COAT HOOK : AKP-CHR-35761P OREQUIVALENT.) 168 Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. ( MAKE-1: JAQUAR, MODEL NO. GRAB BAR : AKP-CHR-35701PS OREQUIVALENT.) 169 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. ( MAKE-1: JAQUAR, MODEL NO. 2 WAY BIB COCK : FLR-CHR-5041NG OREQUIVALENT.) 170 Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector. 171 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required. (MAKE-ModiGuard Sparkle Mirror ) 172 Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe. 173 Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect.100 mm dia 174 Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes andsockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge. 175 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge.Circular Type 125 mm nominal dia with 25 mm waste hole 176 Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 177 Capacity 15 litres size 448X448X345mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : ELENA OREQUIVALENT.) 178 Capacity 35 litres size 875X400mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : VERSA HORIZONTAL MANUAL OREQUIVALENT.) 179 Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC Plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and spcified (In Terrace & Shaft- Hot Water Supply) 180 (Note: Ball Valve and union will be charged extra and does not comes under Accessories) In internal Wall - Exposed on Wall 181 20 mm OD 182 25 mm OD 183 32mm OD 184 40 mm OD 185 Providing and fixing GI pipes(IS:1239 Heavy Class) complete with GI fittings and clamps, i/c cutting and making good the walls etc.(In Terrace & Shaft- Cold & Flushing Water Supply) 186 Internal work - Exposed on Wall 187 25 mm nominal bore 188 32 mm nominal bore 189 50 mm nominal bore 190 Providing and fixing G.I. pipes(IS:1239 Heavy Class) complete with G.I. fittings including trenching and refilling etc.(For External Riser Pipe) 191 External Work 192 25mm nominalnominal bore 193 32mm nominalnominal bore 194 40mm nominalnominal bore 195 50mm nominalnominal bore 196 65 mm nominal nominal bore 197 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 198 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 199 25mm nominal bore 200 32mm nominal bore 201 50mm nominal bore 202 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 203 20 mm nominal bore 204 25mm nominal bore 205 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with brass unions : 45 cm length 206 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 207 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 208 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 209 25mm diameter pipe 210 32mm diameter pipe 211 50mm diameter pipe 212 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 213 25mm diameter pipe 214 32mm diameter pipe 215 40mm diameter pipe 216 50mm diameter pipe 217 65mm diameter pipe 218 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 219 25mm diameter pipe 220 32mm diameter pipe 221 40mm diameter pipe 222 50 mm diameter pipe 223 65 mm diameter pipe 224 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 225 15 mm nominal bore 226 20 mm nominal bore 227 25 mm nominal bore 228 32 mm nominal bore 229 40 mm nominal bore 230 50 mm nominal bore 231 65 mm nominal bore 232 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 233 Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS:8931 with flow rate 2.5 litre per minute at 3 bar: (MAKE-1: JAQUAR, MODEL NO. SHORT BODY BIB COCK : FLR-CHR-5037NG OREQUIVALENT.) 15mm nominal bore 234 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms with flow rate 2.5 litre per minute at 3 bar. (MAKE-1: JAQUAR, MODEL NO. LONG BODY BIB COCK : FLR-CHR-5047NG OREQUIVALENT.) 15mm nominal bore 235 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. (MAKE-1: JAQUAR, MODEL NO. ANGLE VALVE : AQT-CHR-3057 OREQUIVALENT.) 236 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 237 50 mm dia 238 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 239 Internal work - Exposed on Wall 240 65 mm diameter pipe 241 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 242 65 mm diameter pipe 243 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 244 65mm dia. 245 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 246 65mm dia. 247 Providing, laying and joining in position HDPE pipes with slipon flange, High density Poly Ethylene pipe and conforming to I.S. 4984-1995 of required grade / class, 16kg/sq.cm pressure and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. 248 110 mm dia. (OD) (16.0 kgf/sq cm.) 249 160 mm dia. (OD) (16.0 kgf/sq cm.) 250 Providing and fixing motorised butterfly valve with Control Panel & Float Type Magnetic Level Sensors suitable for 220-230 volts AC to operate valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box (upto 6 mt qty approx.) etc., complete. 32 mm dia 251 Supply installation, testing and commissioning of self-contained Drinking water cooler with inbuilt RO confirming to IS: 1475 with amendment no. 1 to 7, suitable for operation on 230 volts ± 10%, 50 Hz, single phase A.C. supply. The two tank inbuilt (hot & cold) and body casing of the water cooler shall be made out of stainless steel. The water cooler will be of following capacities with two numbers faucets / stop cocks (1 no Normal water & 1 no of hot water): Nominal Storage Capacity - 40 Ltrs. Hot water Storage Capacity - 40 Ltrs. 252 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 253 200 mm diameter S.W. pipe 254 250 mm diameter S.W. pipe 255 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 256 200 mm diameter S.W. pipe / RCC pipe 257 250 mm diameter S.W. pipe / RCC pipe 258 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 259 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 260 300mm dia RCC pipe 261 450mm dia RCC pipe 262 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 263 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 264 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 265 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 Extra for depth for manholes: Size 90 x 80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 268 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 269 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 350 to 450 mm diameter 270 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 271 Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 272 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 273 Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 274 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 275 Ordinary Rock 276 Hard Rock(requiring blasting) 277 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 278 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). 279 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia. 280 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia. 281 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. 282 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 283 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 284 Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 285 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 286 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 287 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. 80 mm dia. 288 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 289 80 mm dia. 290 Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings. 291 Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase. 292 Providing & fixing cable 6 sq.mm. From submersible pump to panel board. 293 Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet. 294 Earth work in excavation by mechanical means (Hydraulicexcavator) / manualmeansoverareas(exceeding30cmindepth.1.5minwidthas well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 295 All kinds of soil 296 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 297 Extraforeveryadditionalliftof1.5morpartthereofinexcavation /banking excavated or stacked materials. 298 All kinds of soil 299 Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shttering - All work up to plinth level 300 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate40mm nominal size) 301 Centering & shuttering including strutting, propping etc. and removal ofform work for: 302 Foundations, footings, bases of columns etc. for mass concrete. 303 Lintels, beams, plinth beams, girders, bressumers and cantilevers 304 Suspended floors, roofs, landings, balconies and access platform. 305 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 306 SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete upto plinth level. 307 Thermo-Mechanically Treated bars. 308 Providingandlayinginpositionmachinebatchedandmachinemixed design mix M-25 grade cement concrete for reinforced cement concrete work,usingcementcontentasperapproveddesignmix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishingandreinforcement,includingadmixturesin recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,improveworkabilitywithoutimpairingstrengthanddurability as per direction of Engineer-in-charge. 309 All works upto plinth level 310 6mmcementplaster1:3(1cement:3finesand)onceiling/R.C.C. Beams etc. 311 Neat cement punning. 312 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 313 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 314 150 mm dia. R.C.C. pipe 315 Providing and fixing soil, waste and vent pipes 316 100 mm dia 317 Sand cast iron S&S pipe as per IS: 1729 318 Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989 319 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786,havingminimumcrosssectionas23mmx25mmandoverall minimum length 263 mm and width as 165 mm with minimum 112 mm spacebetweenprotrudedlegshaving2mmtreadontopsurfaceby ribbing or chequering besides necessary and adequate anchoring projectionsontaillengthon138mmasperstandarddrawingand suitabletowithstandthebendtestandchemicalresistancetestasper specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cmcementconcreteblock1:3:6(1cement:3coarsesand:6graded stone aggregate 20 mm nominal size) complete as per design. 320 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 321 Rectangular shape 600x450 mm internal dimensions 322 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 323 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 324 Constructingsoakpit1.20x1.20x1.20mfilledwithbrickbatsincluding S.W.drainpipe100mmdiameterand1.20mlongcompleteasper standard design. 325 Constructingbrickmasonrycircularmanhole1.22minternaldiaatbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand)insidecementplaster12mmthickwithcementmortar1:3(1 cement:3coarsesand)finishedwithafloatingcoatofneatcement foundationconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 40 mm nominal size) and making necessary channel in cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)finishedwithafloatingcoatofneatcement,all complete as per standard design : 326 1.68mdeepwithSFRCCoverandframe(heavydutyHD-20gradedesignation)560mminternaldiameterconformingtoI.S.12592,total weightofcoverandframetobenot lessthan 182kg. fixedin cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)includingcentering,shutteringallcomplete. (Excavation,footrestsand12mmthickcementplasterattheexternal surface shall be paid for separately) : 327 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 328 Extradepthforcirculartypemanhole1.22minternaldia(atbottom)beyond 1.68 m to 2.29 m : 329 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 330 Excavatingtrenchesofrequiredwidthforpipes,cable,etc including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soilasrequired,inlayersnotexceeding20cmindepthincluding consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 331 All kinds of soil 332 Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia. 333 Providing, layingandjointingglazed stone warepipes grade class SP-1with stiffmixtureofcementmortarin theproportionof1:1 (1cement :1 fine sand) including testing of joints etc complete. 150 mm diameter 334 Providingandlayingcementconcrete 1 : 5 : 10 (1 cement : 5 coarsesand : 10 gradded stoneaggregate40 mm nominal size) alround S.W. Pipesincludingbed concrete as per standard design. 150 mm diameter S.W.Pipe 335 Earthwork in excavation by mechanical means ( Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, with in a lead of 50m. All kind of soil 336 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials 337 All kinds of soil 338 Qty for 1.5-3.0 M depth RWH & Desilt Chamber 339 Qty for 3.0-4.5 M depth RWH-Rate 2 Times 340 Qty for 4.5-5.75M depth-RWH -Rate-3 Times 341 Providingorange color safety foot rest of minimum 6mm thickplasticencapsulated as per IS : 10910 on12mm dia steelbar conformingto IS :1786 having minimum cross section as 23mm x 25mm and over allminimum length 263mm andwidth as 165mmwith minimum 112mm space between protrude legshaving2mm tread on top surface by ribbing or chequering besides necessary andadequate anchoring projections on tail length on 138mmas per standard drawing and suitable to with dtand the bendtest andchemical resistancetest as per specifications and havingmanufacturespermanent identification make to be visible even afterfixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 342 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 343 12 mm cement plaster finished with a floating coat of neat cement of mix : 344 1:3 (1 cement: 3 fine sand) 345 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 346 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 347 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 348 Cement mortar 1:6 (1 cement :6 coarse sand) 349 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 350 All types of soil 351 300 mm dia 352 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 353 200 mm nominal size dia 354 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 355 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 356 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 357 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 358 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge 359 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 360 Centering and shuttering including strutting, propping etc. and removal of form for 361 Suspended floors, roofs, landings, balconies and access platform 362 Edges of slabs and breaks in floors and walls 363 Under 20 cm wide 364 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 365 TMTsteel bars 366 Providing, fixing, commissioing, testing and of open well submersible pump for each pump IP 58 protected electric enclosure comprising of 2 Nos. Electrical Driven Horizontal pumps with all accessories coupled to motor suitable for operation on 200-240 volts, 1 phase 2900 RPM. motor with SS 304 body all accessories such as NRVs, valves, common delivery header complete in all repsects. Pumps shall be suitable for 200-240volts 1 phase 50 Hz A.C supply & shall be having the following specifications. Moc of pump -Impeller- CI, csing - CI , shaft- SS 410. Delivery header including all GI pipes, CI valves, CI NRV, bourden type Pressure gauge & accessories complete. 367 All accessories for running two pumps with dry running protection etc. 368 FOR DOMESTIC TRANSFER PUMP 369 No. ofPumps: 2 (1 Working + 1 Stand by ) 370 Capacity:120 LPM 371 Head :30m 372 FOR GARDEN IRRIGATION PUMP 373 No. ofPumps: 2 (1 Working + 1 Stand by ) 374 Capacity:140 LPM 375 Head :30m 376 Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connectedto TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect 377 SUBMERSIBLE UNDER GROUND FOR BOREWELL 378 No. ofPumps: 1 (1 Working ) 379 Capacity:160 LPM 380 Head :60 m 381 SUBMERSIBLE UNDER GROUND FOR BOREWELL 382 No. ofPumps: 1 (1 Working ) 383 Capacity:160 LPM 384 Head :60 m 385 Supply installation testing and commissioning of filtration plant for kund cap. 50cum/hr. including pumps, filters, piping , valves and pumps complete in all respect. 386 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level. 387 All Types of Soil 388 300mm dia 389 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All Types of Soil 300mm dia 390 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 391 200 mm nominal size dia 392 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 393 200 mm nominal size dia 394 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 395 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 396 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 397 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 398 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 399 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch modular plate suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 400 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 401 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 402 Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 403 Wiring for light plug points / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 404 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 405 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 406 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 407 2x10 sq. mm + 1x6 sq. mm earth wire 408 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 409 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 410 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 411 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. 412 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 413 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 414 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 415 Supplying and fixing brass batten/ angle holder including connection etc. as required. 416 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 417 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 418 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 419 SITC of Input power : 20W LED, compact and minimilist surface mounted designed for ceiling & pendant mount. Beam angle 110°(Fixed). Luminaire made of extruded anodised aluminium (grade 6063) of high corrosion resistance, polycarbonate end caps and non corrosive stainless steel fasteners. Polycarbonate diffuser. Protection class IP20. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM = 3 MacAdam. K-Lite LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor>0.95, THD<10%, Surge protection 3KV. Luminaire dimension : 1200mm length x 43mm width x 52mm height. CE & BIS Certified. Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 420 SITC of Input power : 18W led, ceiling mounted compact downlight. Beam angle 15° / 25° / 40°. Luminaire made of extruded aluminium, pressure die-cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Gravity die cast aluminium plate for surface mounting on ceiling. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 100mm diameter x 150mm height. CE & BIS Certified. Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 421 Supply, installation, testing & commissioning of 595mm/600mm mm long surface mounting type LED fitting with diffuser having a lumen output not less than 1100 lumens, CCT 4000K and LED efficacy better than 110 lumen/ watt with opal diffuser in polycarbonate complete with CRCA / Pressure Die Cast Aluminium Housing and life of 50K burning hours (L 70) at 30 deg , THD =10%, CRI better than 80 with inbuilt protection against short circuit, over voltage protection and surge protection of up to 2 KV including connections etc. as reqd. 422 Supplying and fixing of 250 mm sweep Exhaust fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required. 423 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 424 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 425 6 way , Double door 426 12 way, Double door 427 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 428 8 Way (4+24), Double Door 429 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 430 For 6 way, Double door SPN MCBDB 431 For 14 way, Double door SPN MCBDB 432 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. 433 For 8 way, Double door TPN MCBDB 434 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 435 Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 436 25 Amp DP MCB 437 40 Amp DP MCB 438 Supplying and fixing of following rating, 240/415 volts, C curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amp FP MCB 439 Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 100 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 440 25 Amps 441 40 Amp 442 63 Amp 443 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 444 Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitablesize wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. 445 The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. 446 All Main Distribution board / Sub Distribution board / Meter boards which are located inside various blocks shall be partially Type Tested assemblies (PTTA) as per conforming to IEC-61439-1 447 The Moulded Case Circuit Breaker shall have a minimum fault breaking capacity (Ics) of not less than 35 KA & 25KA RMS for one second at 415 volts for MDB / SDB respectively. MCCB‘s above 63A should be provided with Copper & procader terminals. Incomer of Meter Board shall have a minimum short circuit breaking capacity (Ics) of 25KA for one second at 415volt. 448 ELECTRICAL PANEL 449 INCOMING 450 1 No. 125 Amp FP Moulded Case Circuit Breaker. 451 1 Set of phase indicating lamps with MCB. 452 1 Set of ON/OFF indicating lamps with MCB. 453 1 No. Digital MFM with CTs. 454 BUSBAR 455 150 Amp TPNaluminium busbar with coloured heat shrinkable sleeve. 456 OUTGOING 457 9 Nos. 40 / 63 Amp TPN Miniature Circuit Breaker. 458 3 Nos. 25 / 40 Amp DP Miniature Circuit Breaker. 459 Panel described as above 460 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 461 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 462 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 463 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 464 Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required. 465 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 466 Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum ConductorFRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. 467 3.5 core,50 sq.mm. 468 4 core,4 sq.mm. 469 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 470 Upto 35 sq. mm 471 Above 35 sq. mm and upto 95 sq. mm 472 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 473 3½ X 50 sq. mm (35mm) 474 4 X 10 sq. mm (25mm) (Also Used for 4 X 6 sq.mm) 475 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia 476 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness 477 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 478 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 479 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 480 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 481 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 482 Extra for depth beyond 45 cm of brick masonry chamberFor 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 483 Extra for depth beyond 45 cm of brick masonry chamberFor 600x850 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 484 SITC ofIn-Ground 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Input power : 9W led DimensionØ173 x 220 mm Beam Angle : 40° (Tiltable 20°) Electronic driver ON/OFF CE and BIS, IP rating IP67 Die-Cast aluminium alloy housing (grade ADC12 with test certificate). 316 grade stainless steel front ring. Silicone seal gasket. SS fasteners. Mechanical resistance IK09. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. ABS plastic installation housing for preparing the recess opening in ground. The luminaire are fixed in recess installation housing by stainless steel screws. Clear toughened glass diffuser with controlled upward light emission. Lamp fixed position This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >80%, power factor >0.90, THD <15%, Surge protection 2KV.Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 485 SITC ofInput power : 18W,surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 160mm length x 100mm width x 154mm height. CE & BIS Certified. Inhouse NABL accredited lab Make :- K-Lite /Ligman/ Unilamp 486 SITC of Flexible LED Strip 3000K, 4000K, 6000K24Vdc CRI >80 MacAdam step 3 Input power : 12W led Dimension1000 x 12 mm Beam angle : 120° Electronic driver ON/OFF (External driver) CE and BIS, IP rating IP67. Copper coated flexible strip, Silicone moulded diffuser, End cap . Silicone moulded diffuser This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >10,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV.Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 487 FEEDER PILLAR(OUTDOOR TYPE) 488 Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust, vermin & weather proofFloor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thickCRCA sheet complete with followingequipments, includingdigital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CTs, internal wiring with suitablesize wires / cable, MS Angle stand for installation, RCC foundation, interconnection, painting complete as per specification & drawing. 489 INCOMING 490 1 No. 40 Amp FP Moulded Case Circuit Breaker. 491 1 No. 0 to 500 Volt digital voltmeter with inbuilt selector switch. 492 1 No. 40 Amp digital ammeter with inbuilt selector switch and CTs. 493 1 Set of phase indicating lamps with Single Pole MCB. 494 1 Set of ON / OFFindicating lamps with Single Pole MCB. 495 BUS BARS 496 100 Amp TPNaluminium busbar. 497 OUTGOING 498 1 Set 24 Hrs TSQ Timer 499 1 Set 40 Amp, TP Contactor & A/M switch and Push Button. 500 8 Nos. 20 Amp TP MCB, 10 KA breaking capacity. 501 Panel described as above 502 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 503 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fiat user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 504 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end. Approved Makes:Derwiser/Nexans/Siemon/Systimax 505 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 506 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 507 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 508 Supply, Installation, Testing & Commissioning of 15Uwall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Approved Makes: Derwiser/MTS/Rittal/APC/APW 509 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 510 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for camera at user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 511 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 512 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity. Approved Makes:Derwiser/Nexans/Siemon/Systimax 513 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 514 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 515 Supply, Installation, Testing & Commissioning of L2+ managed industrial PoE fiber switch with 24*10/100/1000M RJ45 ports and 4*1//10G SFP slot ports, Port 1-24 can support IEEE802.3af/at PoE.Switching capaticy of128Gbps, forwarding Rate 95.23 Mpps, having24 x 10/100/1000BASE-T PoE-plus(RJ45) with maximum PoE output power is 400W, 1 RS232 Console port.32K MAC address. Should have Static Routing ,system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP),and IPv6 features from day 1, Security Feature: Port Isolation, VLAN, MAC, Spanning tree, Multicast, DDM, ACL, QoS: 802.1p (COS), DSCP, SP, WRR, Classification based on source IP, destination IP, and port number etc.Approved Make :Cisco/ Impulse / Juniper / Nexxus 516 Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5 SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest.Approved Makes: HP / DELL / IBM / LENOVO 517 Supply, Installation, Testing & Commissioning of 8TB Surviellance Hard Disk. Approved Makes: WD /segate /Toshiba/HP 518 Supply, Installation, Testing and Commissioning of Full HD 55 LED Professional Display Panel.Approved Makes: Panasonic / LG/ Sony/ Samsung 519 Supply, Installation, Testing & Commissioning of Pure IP at core server Based voice solution with04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,28 IP users License ,01 Nos. IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode.Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 520 Supply, Installation, Testing & Commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE .Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 521 Supply, Installation, Testing & Commissioning of 24 Port PoE Access Switches with switching capaticy of 300 Gbps, forwarding performance 240 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 720W and 4x 10G SFP+ uplink ports . Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address, 8K Multicast Routes, Should have static Routes from day 1.Approved make - Cisco / Juniper /Impulse / Nexxus/Arista 522 Supply, installation, testing and commissioning of 5 MP Bulletcamera ,ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Quad stream support,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : Shutter speed :1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support up to 256GB, frame rate : Main stream should support 25 fps@5MP , Edge analytics : Customer Flow staistics,Cross Count Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 30 meters , IP 66 , POE. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 523 Supply, installation, testing and commissioning of32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out : 16chin / 4chout , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , 1x3.0 USBfor backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR .Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000,A.I maximum captured quantity200,000. UL,CE,FCC certified. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 524 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
TenderDetail
Loading tenders