View Bid Results For Mafron Gas Tenders

We found 76 Bid Results related to mafron gas tenders. You can find Contractor details who won mafron gas tenders along with contract details in Bid awards announcements section.

Filters
Stage
74
2
Tender Publishing Platform
39
37
State / UT
17
21
9
6
5
5
4
4
4
3
3
3
2
2
2
1
1
1
Contract Value
32
24
20
Publish Date
1
0
0
0
0
Sector
11
27
19
18
4
2
1
1
1
1
1
1
Ownership
3
33
28
15
Within keyword
Active filters:
Showing 1–2 of 76 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 1.83 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 26,096
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
8.
Railways #11227717 AOC
Supply Of 1.Non-Cfc Refrigerant R-32 Gas, Difluoromethane (Ch2f2), Categorized Non Toxicity, Belong To Hfc Family Refrigerant Lower Global Warming Potential (Wgp 675) In Compliance With El No.517/2014, Suitable For Inverter Type Split Ac Units , Supply In Sealed 8Kgs Capacity Cylinders On Returnable Basis. Makes: Floron, Dupoint, Mafron Or Similar. 2.Refrigerant Gas R-22 Conforming To Is: 5610/1993, Reafirmed- 2006 Or Latest Should Be Supply In 10Kg Sealed Cylinder On Returnable Basis, Make: Floron, Mefron, Duupoint Or Similar. 3.Non Cfc Refrigerant R-410A Gas, Azeotropic Mixture Of Difluoromethane (Ch2f2) And Pentafluoro Ethane (C2hf5), Should Be Supplied In 9 Kgs Sealed Cylinders On Returnable Basis, Make: Floron, Dupoint, Mafron Or Similar1.Non-Cfc Refrigerant R-32 Gas, Difluoromethane (Ch2f2), Categorized Non Toxicity, Belong To Hfc Family Refrigerant Lower Global Warming Potential (Wgp 675) In Compliance With El No.517/2014, Suitable For Inverter Type Split Ac Units , Supply In Sealed 8Kgs Capacity Cylinders On Returnable Basis. Makes: Floron, Dupoint, Mafron Or Similar. 2.Refrigerant Gas R-22 Conforming To Is: 5610/1993, Reafirmed- 2006 Or Latest Should Be Supply In 10Kg Sealed Cylinder On Returnable Basis, Make: Floron, Mefron, Duupoint Or Similar. 3.Non Cfc Refrigerant R-410A Gas, Azeotropic Mixture Of Difluoromethane (Ch2f2) And Pentafluoro Ethane (C2hf5), Should Be Supplied In 9 Kgs Sealed Cylinders On Returnable Basis, Make: Floron, Dupoint, Mafron Or Similar,Non Cfc Refrigerant R-410A Gas, Azeotropic Mixture Of Difluoromethane (Ch2f2) And Pentafl Uoro Ethane (C2hf5), Should Be Supplied In 9 Kgs Sealed Cylinders On Returnable Basis, Make: Floron, Dup Oint, Mafron Or Similar [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Refrigerant Gas R-22 Conforming To Is: 5610/1993, Reafirmed- 2006 Or Latest Shoul D Be Supply In 10Kg Sealed Cylinder On Returnable Basis, Make: Floron, Mefron, Duupoint Or Similar. [ Warranty Period: 30 Months After The Dat
Contract Date: Jun 05, 2026 Contract Value : 2.47 Lakh
Government Departments No of Bidders 1
Andhra Pradesh View Result →
Contract Date: Jun 19, 2026 Contract Value : 2.11 Lakh
Government Departments No of Bidders 2
13.
Petroleum and Natural Gas #9738524 AOC
Bids Are Invited For Mafron Gas Total Quantity : 1525
Contract Date: Ref. Documents Contract Value : 12.66 Lakh
Boards / Undertakings / PSU No of Bidders 4
Contract Date: Ref. Documents Contract Value : 16,795
Statutory Bodies & Commissions/Committees No of Bidders 3
15.
Defence #9638857 AOC
Tender For Repairs/Maintenance Of Summer Appliances And Certain Misc Air Conditioning Works In West Wing Tech Area And Domestic Area Of Af Station Gwalior- 1 Repair, maint and making the continuity of cooling effect of Split AC / Window AC / cassette AC / Tower AC complete by replacement of defective parts such as PCB, compressor, condenser, capacitor, fan blade, fan motor, Refrigerant topping up, water leakage, leak test, blower motor, blower us, cleaning of indoor and outdoor unit, electric wiring, control wiring, inverter PCB, thermostate, no supply and other similar AC spare parts etc. complete all as specified and directed by Engineer-in-Charge Note :- (i) Any accessories found unserviceable that shall be replaced under respective items of this Sch.(ii) Contractor has to provide sufficient manpower minimum 02 AC Technician and 02 helper alongwith necessary tools for repair of AC daily including sunday / holidays for resolving timely complaints and rates shall be included in the quoted rates.(ii)The replacement of defective / nonfunctional parts except compressors during repair work shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (iii)Necessary transportation arrangement for attending day to day AC complaint and taking down unserviceable ACs from user site to workshop & civil area included in the quoted rates.(iv)Recovery of Rs 500 per day will be recovered for non attending of complaint within 24 hours daily till its serviceability except leak test, compressor replacement, condenser replacement, indoor unit replacement, inverter PCB, shifting of ACs 2 Supply only following items ofAir conditioning split/windowtype AC of capacity 1.5/2/3TRof any make/model/ capacity including checking of defects and rectified. (a) Supply only in replacement with new Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC supply. Make M/s Asian / M/s Unistar / M/s Epcos / M/s Electro complete all as specified and as directed. 3 Supply only in replacement with new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply complete all as specified and as directed. 4 Supply only in replacement with new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ ACsupply complete all as specified and as directed. 5 Supply only in replacement with new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply complete all as specified and as directed. 6 Supply only in replacement with new Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC supply.complete all as specified and as directed. 7 Supply only in replacement with new Running capcitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC supply complete all as specified and as directed. 8 Supply only in replacement with new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC supply complete all as specified and as directed. 9 Supply only in replacement with new PVC braded drain pipe of size 15 mm inner dia 10 Supply only in replacement with new PVC braded drain pipe of size 20 mm inner dia 11 Supply only in replacement with new PVC braded drain pipe of size 40 mm inner dia 12 Supply only in replacement with new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unitsuitable for Split AC/Window AC1.5/2.0 TR of capacity, model and make as per existing all as directed. 13 Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC/window AC upto3.0 TR inverter type as per existing make and model. 14 Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR capacity Non inverter type, model and make as per existing all as directed. 15 Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR cassete type of any model and make as per existing all as directed. 16 Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing all as directed. 17 Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR complete all as specified and directed. 18 Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR complete all as specified and directed. 19 Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 3TR complete all as specified and directed. 20 Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type Cassete AC 3TR including complete all as specified and directed. 21 Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase non inverter type complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site 22 Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR/3 TR split AC Single Phaseinverter type complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site 23 Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase complete all as specified and directed at site. 24 Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site 25 Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Three Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site 26 Supply only in replacement with new capillary tube of size as per sample suitable for split AC 1.5TR/2TR/3TR and window type AC of any make complete all as specified and directed. 27 Supply only in replacement with new Liquid line copper filter as per sample suitable for 1.5/2 TR split/window AC. 28 Supply only in replacement with new Liquid line copper filter as per sample suitable 3 TR split AC. 29 Supply only in replacement with new Over load Relay as per sample suitable for any type split type 1.5/2 TR Capacity. 30 Supply only in replacement with new Over load Relay as per sample suitable for any type split type 3 TR Capacity. 31 Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeACs of Capacity 1.5/2 TR. 32 Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeACs of Capacity 3 TR. 33 Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split ACs any make as existing. 34 Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5 /2 TR Capacity as per existing make and model. 35 Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TR Capacity as per existing make and model. 36 Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5/2 TRcapacity inverter type as per existing make and model. 37 Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TRcapacity inverter type as per existing make and model. 38 Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 1.5 / 2 TR Capacity. 39 Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 3 TR Capacity. 40 Supply only in replacement with new flapper suitable for Split AC as per sample for capacity 1.5 to 3 TR 41 Supply only in replacement with new PVC Grills as per sample and for any make window AC. 42 Supply only in replacement with new Thermostate switch with knob 230 volts for Window AC 43 Supply only in replacement with new Check valve any dia for upto 3 TR capacity Split ACs as per sample. 44 Supply only in replacement with new Expansion valve complete set as per sample suitable for 1.5 / 2 TR Spllit AC. 45 Supply only in replacement with new Expansion valve complete set as per sample suitable for 3 TR Spllit AC. 46 Supply only in replacement with new Ventury as per sample made of thermo-coal insulationsuitable for Window AC . 47 Supply only in replacement with new Pre-air filter made up of PVC for indoor unit as per sample of split AC suitable for any capacity make and description complete 48 Supply only in replacement with new Brass service valve of 5/8 dia with flare unit as per sample for split type AC as per existing model and shape. 49 Supply only in replacement with new Brass service valve of 3/8 dia with flare unit as per sample for split type ACas per existing model and shape. 50 Supply only in replacement with new Brass service valve of 1/2 dia with flare unit as per sample for split type ACas per existing model and shape. 51 Supply only in replacement with new Brass service valve of 1/4 dia with flare unit as per sample for split type ACas per existing model and shape. 52 Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacityand reassembling, fixing and testing the dismantled AC in new position after making necessary cutting/openingand making good in window frame complete all as specified and directed.Note- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A. 53 Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packings etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid seperatly under appropriate item of schedule A 54 Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 3/8 bore. 55 Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 5/8 bore 56 Supply and fixing in replacement with new copper tubing of special annealed pressure copperof size 1/4 bore 57 Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/2 bore 58 Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 3/8 bore 59 Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 5/8 bore 60 Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 1/4 bore 61 Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 1/2 bore 62 Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed. 63 Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 3 TR split AC complete all as specified and directed . 64 Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per samplecomplete suitable for 1.5 TR Split Acs 230 volts of existing make, vaccumising and pressure testing is inclusive in the quoted rates. 65 Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed and suitable for 2 TR Split Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 66 Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed and suitable for 3 TR Split AC Single Phase 230 volts of existing make. vaccumising and pressure testing is inclusive in the quoted rates. . 67 Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed andsuitable for 3 TR Three Phase Split Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 68 Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per samplecomplete all as directed andsuitable for 1.5 TR Single Phase Window Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 69 Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per sample complete all as directed andsuitable for 2 TR Single Phase Window Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 70 Supply and fixing in replacement with new Rotary compressor as per sample complete and suitable for 1.5 TR Split AC Single phase 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 71 Supply and fixing in replacement with newRotary compressor as per sample complete all as directed and suitable for 2 TR Split AC Single phase 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 72 Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed and suitable for 3 TR Split AC Single phase 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. 73 Supply and fixing in replacement with newRotary compressor as per sample and suitable for 3 TR Split AC Three phase 230 volts of existing make. complete all as directed vaccumising and pressure testing is inclusive in the quoted rates. 74 Supply and fixing in replacement with newRotary compressor as per sample and suitable for 1.5/2.0 TR Inverter Split AC Single phase 230 volts of existing make and model. complete all as directed vaccumising and pressure testing is inclusive in the quoted rates. 75 Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB. 76 S & F in replacement with new Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps. 77 Supply and fixing in replacement with new 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. 78 Supply and fixing in replacement with new SPN 40 to 63 amp rating 240V, 10KA C curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning. 79 Supply and fixing in replacement with new TPN / FP 32 Amp 415V 10KA B curve miniature circuit breaker (MCB)and current carrying capacity in the DB complete with connection testing and commissioning. 80 Supply and fixing in replacement with new power contactor single phase, 2 pole, AC 220 Volt, short circuit 5 kA RMS, AC-8a as per existing make and model complete all as specified and directed. 81 S&F in replacement of terminal plate for 8 incoming and outgoing connection alongwith suitable size copper lugs suitable for outdoor unit of split AC 1.5/2.0/3.0 TR single / three phase AC complete all as specified and directed. 82 M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed. 83 M & L for water jet / foam servicing of indoor /outdoor unit of split / window AC any capacity complete including covering with suitable size water proof cover for prevention of water leakage during servicing and necessary C-Sine or equivalent chemical for cleaning of cooling / condenser coil all as specified and directed 84 Supply of Refrigerant gas (R-22) Monochloro Difluoro Methane (CHCLF2) (Make :- Mafron-22/Refron-22/Floron 22) duly filled in factory sealed cylinder complete all as specified and directed.Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas. 85 Supply of Refrigerant gas (R-410)(Non CFC) duly filled in factory sealed cylindercomplete all as specified and directed. Make :- Mafron/Floron Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas. 86 Supply of Refrigerant gas (R-32)(Non CFC) duly filled in factory sealed cylindercomplete all as specified and directed. Make :- Mafron/Floron Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas. 87 S & F in repair Voltage Monitor three phase protection device for three phase system having protection against High, Low Voltage , Single Phasing and Reverse phase sequence as per sample 88 Repair of any type PCB of any type AC (Inverter / Non Inverter) as per Sample suitable for1.5 / 2/ 3 TR split / window / cassette / tower AC complete all as specified and directed by Engr - in - Charge. 89 Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 5.0 KVAcomplete all as specified and directed 90 Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed 91 Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed 92 S&F PVC insulated & sheathed copper round cable 1100 volts of size 4.0 sqmm 3 core incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. 93 All as per item No 92 but of Size 4.0 sqmm 4 core 94 All as per item No 92 but of Size 4.0 sqmm 5 core 95 All as per item No 92 but of Size 6.0 sqmm 3 core 96 All as per item No 92 but of Size 10 sqmm 3 core 97 Supply and fix in replacement Heavy Duty Air Conditioner Outdoor AC Stand for 1.0 to 3.0 TonShelf Bracket(Steel) complete with fixing accessories. 98 M & L for wirting SM/MES No in indoor unit of Split / Window AC/ Refrigerator / Water cooler/ Deep freezer etc any capacity with approved colour of synthetic enamel paint complete all as specified and directed. 99 M & L for replacement of outdoor MS wire mesh for protection of fan blade including fixing arrangement in existing AC complete all as specified and directed. 100 M & L for spray painting of outdoor unit of Split AC any capacity with approved colour including filling of cavity and repair of damaged portion of outdoor unit complete all as specified and directed. 101 S&F in replacement of wall mounting type AC timer havingDelay Time Facility, Auto & manual switch ,Suitable for window ,split type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals all as specified and directed by Engineer-in-Charge.
Contract Date: Feb 21, 2026 Contract Value : 34.29 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
17.
New and Renewable Energy #9044036 Technical Bid
Supply Of Refrigerants For Different Cooling Systems , Supply Of Refrigerants For Different Cooling Systems , Brand New High Grade Steel Typer22gas Cylinderalong With 10 Kgs Of R22-Gas ( Tolerable Limit Of + / - 1% In Weight ) , Brass Typetop Valve / Adopter & Guardand Standard Length Of Good Quality Ofhose With Pressure Guage , Cylinder Key And Hardware Kit . Make:Floron / Stallion / Dupont / Refron / Mafron / Equivalent In All Other Brands. ( Note: Bidder Shall Submit Their Quote By Considering Ofthe Cost Of Cylinder , Gas& All Accessories. ) , Brand New High Grade Steel Typer22gas Cylinderalong With 61 Kgs Of R22-Gas ( Tolerable Limit Of + / - 1% In Weight ) , Brass Typetop Valve / Adopter & Guardand Standard Length Of Good Quality Ofhose With Pressure Guage , Cylinder Key And Hardware Kit .Make:Floron / Stallion / Dupont / Refron / Mafron / Equivalent In All Other Brands. ( Note: Bidder Shall Submit Their Quote By Considering Ofthe Cost Of Cylinder , Gas& All Accessories. , Brand New High Grade Steel Typer32gas Cylinderalong With 08 Kgs Of R32-Gas ( Tolerable Limit Of + / - 1% In Weight ) , Brass Typetop Valve / Adopter & Guardand Standard Length Of Good Quality Ofhose With Pressure Guage , Cylinder Key And Hardware Kit .Make:Floron / Stallion / Dupont / Refron / Mafron / Equivalent In All Other Brands. ( Note: Bidder Shall Submit Their Quote By Considering Ofthe Cost Of Cylinder , Gas& All Accessories. , Brand New High Grade Steel Typer134agas Cylinderalong With 10 Kgs Of R134a-Gas ( Tolerable Limit Of + / - 1% In Weight ) , Brass Typetop Valve / Adopter & Guardand Standard Length Of Good Quality Ofhose With Pressure Guage , Cylinder Key And Hardware Kit . Make:Floron / Stallion / Dupont / Refron / Mafron / Equivalent In All Other Brands. ( Note: Bidder Shall Submit Their Quote By Considering Ofthe Cost Of Cylinder , Gas& All Accessories. , Brand New High Grade Steel Type07 Cubic Metersize Nitrogengas Cylinderalong With Full Capacity Of Nitrogen Gas ( Tolerable Limit Of + / - 1% In Weight ) , Brass Typetop Valve / Adopter & Guardand Standard Length Of Good Quality Ofhose With Pressure Guage , Cylinder Key And Hardware Kit .Make:Floron / Stallion / Dupont / Refron / Mafron / Equivalent In All Other Brands. ( Note: Bidder Shall Submit Their Quote By Considering Ofthe Cost Of Cylinder , Gas& All Accessories. , Suitable Brass Type Top Valve / Adopter For Above Application Purpose. , Standard Good Quality Of Hose Pipe Alongwith Connectors And Pressure Guagefor The Application Of Top Up / Transfer Of Refrigerants. , Suitable Good Quailty Of Heavy Duty Type Shifting Trolley For The Application Of Shifting Of 10-Kg Gas Filled Cylinders ( For Si.No:01 ) . , Suitablegood Quality Ofheavy Duty Type Shifting Trolley For The Application Of Shifting Of 61-Kg Gas Filled Cylinders. ( For Si.No:02 )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 10,965
Statutory Bodies & Commissions/Committees No of Bidders 2
Contract Date: Ref. Documents Contract Value : 15,781
Statutory Bodies & Commissions/Committees No of Bidders 6
Contract Date: Ref. Documents Contract Value : 39.04 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 2.44 Lakh
Boards / Undertakings / PSU No of Bidders 6
Contract Date: Ref. Documents Contract Value : 10.79 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 54,445
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 20,921
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 71.26 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 22.15 Lakh
Boards / Undertakings / PSU No of Bidders 2
Chhattisgarh View Result →
36.
Educational and Research Institute #7140266 AOC
Tender For Rate Contract For Supply Of Material Required For Day To Day Maintenance Of Split , Window Ac And Water Coolers Of Different Capacities Installed In Institutional Buildings For The Year 2024-25 In M.D.U. Rohtak-- 1 Capacitor 1.5 Mfd MakeEpcos/ GC/ Tibcon 2 Capacitor 4 Mfd MakeEpcos/ GC/ Tibcon 3 Capacitor 6 Mfd MakeEpcos/ GC/ Tibcon 4 Running capacitor Aluminium cap 36 Mfd. Epcos/ GC/ Tibcon make 5 Running capacitor Aluminium cap 45 Mfd. Epcos/ GC/ Tibcon make 6 Running capacitor Aluminium cap 45+6 Mfd. Epcos/ GC/ Tibcon make 7 Running capacitor Aluminium cap 50 Mfd. Epcos/ GC/ Tibcon make 8 Running capacitor Aluminium cap 50+6 Mfd. Epcos/ GC/ Tibcon make 9 Running capacitor Aluminium cap 60 Mfd. Epcos/ GC/ Tibcon make 10 Running capacitor Aluminium cap 60+6 Mfd. Epcos/ GC/ Tibcon make 11 Starting capacitor Aluminium cap 100-120 Mfd. Epcos/ GC/ Tibcon make 12 New fan motor for window AC 1.5 ton copper wound make and model as per existing installed AC with one year guarantee. 13 New fan motor for window AC 2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 14 New fan motor Outdoor for Split AC 1.5 ton copper wound make and model as per existing installed AC with one year guarantee. 15 New fan motor Outdoor for Split AC 2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 16 Bearing for AC fan motor ‘NBC’ / ‘SKF’ make as per requirement of existing installed AC. 17 Connector 32 Amp for AC voltage stabilizer three pin in bakelite. 18 Copper pipe heavy 1/4” ‘Mandev’ make. 19 Copper pipe heavy1/2” ‘Mandev’ make 20 Copper pipe heavy 3/8” ‘Mandev’ make 21 Copper pipe heavy 5/8” ‘Mandev’ make 22 Insulation rubber pipe for covering for copper pipe 5/8 ‘Malayasia’ make 23 Dead nut for Suction Valve brass ¼” 24 Dead nutfor Discharge Valve brasbrass 1/2” 25 Dead nutfor Suction Valve brasbrass 5/8” 26 Flair nut brass 1/4” 27 Flair nut brass 1/2” 28 Flair nut brass 3/8” 29 Flair nut brass 5/8” 30 Silver coated Copper thimble 32 Amp (100 piece in one Pkt.) 31 Fan blower for Window AC 1.5 make and model as per requirement of existing installed AC. 32 Fan blower for Window AC 2.0 ton make and model as per requirement of existing installed AC. 33 Fan Blade for Window AC 1.5 make and model as per requirement of existing installed AC. 34 Fan Blade for Window AC 2.0 ton make and model as per requirement of existing installed AC. 35 Fan blower for Split AC indoor 1.5 ton make and model as per requirement of existing installed AC. 36 Fan blower for Split AC indoor 2.0 ton make and model as per requirement of existing installed AC. 37 Fan blade Split AC 1.5 Ton Outdoor, make and Model, as per requirement of existing installed AC. 38 Fan blade Split AC 2.0 Ton Outdoor, make and Model, as per requirement of existing installed AC. 39 Capilary Pipe Copper Size 55 No. 40 Capilary Pipe Copper Size 60 No. 41 Filter Copper 2 Way 42 Filter Copper 3 Way 43 Pencil valve Copper 1/4 44 Brass Valve 1/4” brass 45 Brass Valve 3/8” brass 46 Brass Valve 1/2” brass 47 Brass Valve 5/8” brass 48 Copper cooling coilBlue Fins for window AC 1.5 ton as per requirement of existing installed AC. 49 Copper cooling coil Blue Fins for window AC 2.0 ton as per requirement of existing installed AC. 50 Copper cooling coil Blue Fins for split AC 1.5 ton as per requirement of existing installed AC. 51 Copper cooling coil Blue Fins for split AC 2.0 ton as per requirement of existing installed AC. 52 Copper condenser coil Blue Fins for split AC 1.5 ton outdoor unit as per requirement of existing installed AC. 53 Copper condenser coil Blue Fins for split AC 2.0 ton outdoor unit as per requirement of existing installed AC. 54 Coil Sensor. Make and model as per existing installed AC 55 Temperature Sensor. Make and model as per existing installed AC 56 New PCB for indoor split AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 57 New PCB for indoor split AC 2.0 ton with Display and Remotet as per requirement of existing installed AC. 58 New PCB for Window AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 59 New PCB for Window AC 2.0 ton with Display and Remotet as per requirement of existing installed AC. 60 New PCB for Inverter Indoor Split AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 61 New PCB for Inverter Indoor Split AC 2.0 ton with Display and Remote as per requirement of existing installed AC. 62 New PCB for Inverter Outdoor Split AC 1.5 ton with Display and Remote as per requirement of existing installed AC. 63 New PCB for Inverter Outdoor Split AC 2.0 ton with Display and Remote as per requirement of existing installed AC. 64 New PCB for Inverter Outdoor Split AC 1.5 ton(Hot and Cold) with Display and Remote as per requirement of existing installed AC. 65 New PCB for Inverter Outdoor Split AC 2.0 ton(Hot and Cold) with Display and Remote as per requirement of existing installed AC. 66 New compressor rotary 1.5 ton GMCC/ ‘Highly’ / ‘Hitachi’’ make with one year guarantee. 67 New compressor rotary 2.0 ton GMCC/‘Highly’ / ‘Hitachi’ make with one year guarantee. 68 New compressor rotary 1.5 ton Scroll make with one year guarantee. 69 New compressor rotary 2.0 ton Scroll make with one year guarantee. 70 New compressor 1.5 ton invertor AC make as per requirement. 71 Newcompressor 2 ton invertor AC make as per requirement. 72 Refilling of R22 gas Mafron, Floron make in existing cylinder provided by the department. 73 Refilling of R32 gas Mafron, Floron make in existing cylinder provided by the department. 74 Refilling of R410 gas Mafron, Floron make in existing cylinder provided by the department. 75 Refilling of Nitrogen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 76 Refilling of Oxygen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 77 New DC fan motor for window AC 1.5/2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 78 New DC fan motor for split ACindoor 1.5/2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 79 New DC fan motor for split AC Outdoor 1.5/2.0 ton copper wound make and model as per existing installed AC with one year guarantee. 80 PVC Drain tray for Window AC 19x22x27 81 Split AC Outdoor Safety Guard 2x2 82 LPG can portable gas cartridge 83 Packing tape 2 size (50 Meter per roll) 84 Drain pipe PVC Flexible (Length6 Feet Each) 85 Drain pipe PVC 25 mm Dia. Length 10 Foot) Make - Prince 86 PVC 25 mm (1) Saddle with 2 Nails 87 PVC 25 mm Tee (1)(Make -Prince) 88 PVC 25 mm Elbow (1) (Make -Prince) 89 PVC Drain Pipe for Indoor Split AC (1.5 Foot) 90 Teflon TapeMake -3M 91 Fevi Bond Tube 92 Steel Screw for Window AC/ Split AC Outdoor 93 Rubber gutka and rubber ring / rubber ring iron clamp model as per requirement for holding fan motor (12+12+12 ) 94 Rubber gutka, rubber ring and Stud for 1.5 Ton/2.0 Ton Compressor for window/ Split AC model as per requirement. 95 Fan Motor Bush ofGun Metal and Shaft of Steel 96 Welding Rod Copper 97 3 Pin Top 16 Amp. 98 AC Plug and Socket Metal Clad Protected 20 Amp 2 Pole (Plug and Socket Set) 99 SPN 40 Amp. Make L &T/Havells/Indoasian 100 TPN 63 Amp. Make L &T/Havells/Indoasian 101 TP 63 Amp. Make L &T/Havells/Indoasian 102 25 Amp Contactor Single Phase Make : L & T 103 Cap Case Batton 50 mm50 mm X 1.5 mm x 2 m Make Precision (L= 6 Feet) 104 PVC Gitti 6 mm. (50 Pcs per Pkt.) 105 Black Screw 1.5 106 Split AC Outdoor Stand 107 Fastener for Split AC Outdoor 8 mm 108 Four Core Wire 2.5 mm. (90 Meter) Make: Havells 109 Single Core 2.5 mm (90 Meter) Make: Havells 110 Remote for existing 1.5 / 2.0 ton window / split AC make ‘Blue Star’ / ‘Hitachi’ / ‘Voltas’ / .Samsung’ 111 M Seal (1 Kg, Each Packet) 112 Cable Tie 75 mm 113 Pencil Cell Type: AAA Make: Duracell 114 PVC TapeMake- Steelgrip,Anchor, Girish 115 New compressor reciprocating 1.1 ton Kirlosker, ‘copeland’ Make with one year guarantee. Old scrapcompressor should not be retained by department. So rates will be quoted by discounting the cost of old compressor. Model No. KCG-513 116 Refilling of R22 gas Mafron, Floron make in existing cylinder provided by the department. 117 R 134 A Gas Mafron, Floron make in existing cylinder provided by the department. 118 Thermostat Copper Make Godrej, Anapurna 119 Capilary Pipe Copper Size 50 No. 120 Filter Copper 3 Way MakeVijay 121 Running capacitor Aluminium cap 45 Mfd. Epcos/ GC/ Tibcon make 122 Running capacitor Aluminium cap 36 Mfd. Epcos/ GC/ Tibcon make 123 Capacitor 4 Mfd MakeEpcos/ GC/ Tibcon 124 Starting capacitor Aluminium cap 100-120 Mfd. Epcos/ GC/ Tibcon make 125 Box Type Relay32 Amp. 126 New fan motor for water cooler 150 Ltrs. copper wound make and model as per existing installedwater cooler with one year guarantee.Old scrap of Motor should not be retained by department. So rates will be quoted by discounting the cost of old Motor. 127 Fan Blade Aluminium 128 Welding Rod Copper 129 LPG can portable gas cartridge 130 Fan Motorrubber ring 131 Fan Motor stand 132 Copper condenser coilfor water cooler 150 Ltrs.as per requirement of existing installed water cooler. Old scrap Coil should not be retained by department. So rates will be quoted by discounting the cost of old condenser coil. 133 Copper pipe heavy 1/4” ‘Mandev’ make. 134 Copper pipe heavy1/2” ‘Mandev’ make 135 Copper pipe heavy 3/8” ‘Mandev’ make 136 Silver coated Copper thimble 32 Amp (100 piece in one Pkt.) 137 Steel Screw for water cooler body 138 Cable Tie 75 mm 139 Drain pipe PVC Flexible of 1.25 Dia. (Length6 Feet Each) 140 Drain Pipe Ring (Dia-1.25) 141 3 Core x 2.5 mm sq copper cable (100 Mtr.) 142 Refilling of Nitrogen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 143 Refilling of Oxygen gas in existing cylinder provided by the department.(capacity of existing cylinder is 7 cubic meter) 144 Pencil valve Copper 1/4 145 PVC TapeMake- Steelgrip,Anchor, Girish
Contract Date: Mar 24, 2025 Contract Value : 21.47 Lakh
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : 10.27 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.60 Lakh
Government Departments No of Bidders 4
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 16.98 Lakh
Government Departments No of Bidders 5
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 50,752
Government Departments No of Bidders 7
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 55,759
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 11,682
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 22,040
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu And Kashmir View Result →
TenderDetail
Loading tenders