View Bid Results For Local Area Network Tenders

We found 741 Bid Results related to local area network tenders. You can find Contractor details who won local area network tenders along with contract details in Bid awards announcements section.

Filters
Stage
601
97
43
Tender Publishing Platform
230
511
State / UT
32
156
104
83
71
38
37
37
23
19
17
13
13
12
12
12
11
11
10
9
8
8
7
7
5
4
4
3
2
2
1
1
1
Contract Value
203
288
177
71
Publish Date
1
0
0
0
0
Sector
29
204
130
67
56
55
45
32
19
18
15
13
12
11
9
9
7
6
5
5
5
5
4
3
1
1
1
1
1
1
Ownership
6
426
147
114
47
6
1
Within keyword
Active filters:
Showing 1–15 of 741 tenders matching your filters
3.
Defence #11370439 AOC
Bids Are invited for Analog Goggles Skyzone Cobra Sd Analog Goggles With Battery - The Skyzone Cobra Sd Analog Fpv Goggles Feature Versatile Power Options, They Can Be Powered Using A Single 18650 Li-Ion Battery, A 2S To 6S Lipo Battery Or A Usb-C Power Bank With High Efficiency , Rj 45 Connector - The Rj45 Registered Jack Is The Standardized 8-Position, 8-Conductor Physical Interface Used For Terminating Ethernet And Networking Cables, Pairs 4 Twisted Pairs Of Wire To Transmit Data And Power Across Local Area Networks , Hi Focas 4G Router - The Hi-Focus 4G Lte Wi-Fi Router Is A Plug-And-Play Solution Designed To Deliver Wireless Internet Using A Standard 4G Sim Card Internet For Offices, For Fixed Broadband , Sata Cable - Sata Cables Are The Primary Interface Used To Connect Internal Storage Drives Like Hdds And Ssds To A Computers Motherboard , Epson Colour Ink Set 001 - The Hepson Colour Ink Set 001 Bk,C,M,Y Is A Highyield Original Ink Set For Epson Printer L6270 For Highvolume Office Environments Professional Quality Text And Graphics. , Electric Battery Heated Sock Foot Warmer - Electric Heated Socks Provide Targeted, Battery Powered Warmth For Outdoor Activities Or Poor Circulation Standard Models Utilize Takes Approximately 3 To 6 Hours For A Full Charge Via A Usb-C Or Wall Adapter Ultra Thin Carbon Fiber Or Alloy Wire Heating Panels , Electric Battery Heating Gloves - Electric Heating Gloves Feature Built-In Carbon Fiber Or Metal Wire Heating Elements Powered By Rechargeable Batteries Or A Usb Connection Touchscreen Compatible , Hp Cd Writer - Hp Cd Writer Such As The Ide-Scsi Cd Writer Series From The Late With Exact Model Number Up To 24X For Cd-R Rw, Up To 8X For Dvdr , E1t1 Card - An E1-T1 Card Acts As An Interface To Connect Digital Telephone Lines To A Server Or Router, Specific Manufacturer, Hardware Models Shairing Universal Parameters , Exchange Cpu - Microsoft Exchange Server They Require Robust 64-Bit Multi-Core Architectures To Handle Heavy Email Routing, Indexing, And Mailbox Databases Total Quantity : 57
Contract Date: Ref. Documents Contract Value : 1.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 39.99 Lakh
Government Departments No of Bidders 11
7.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 26.03 Lakh
Boards / Undertakings / PSU No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 7.75 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 2.55 Lakh
Government Departments No of Bidders 3
14.
Educational and Research Institute #11233758 AOC
Bids Are Invited For Optical Fiber Cable As Per Technical Specifications , Hdpe Pipe As Per Technical Specifications , Trenching Reinstatement As Per Technical Specifications , Liu Accessories , Fiber Splicing Termination As Per Specifications , Ofc Testing Commissioning With Otdr And Power Testing , Route Survey Documentation As-Built Drawings , Indoor Wi-Fi Access Points As Per Technical Specifications , Outdoor Wi-Fi Access Points As Per Specifications , Network Switches Poe As Per Specifications , Network Switches Non Poe As Per Specifications , Structured Cabling As Per Specifications , Casing Capping As Per Specifications , Wi-Fi Controller Nms As Per Specifications , Network Racks 42U As Per Specifications , Network Rack 28U As Per Specifications , Patch Cords As Per Technical Specifications , Local Area Networking As Per Technical Specifications , Server With Windows Server Latest Os As Per Technical Specifications , Dedicated Database Server With Sql Server As Per Technical Specifications , Storage San Or Nas As Per Technical Specifications , Storage Network L3 Core Switch As Per Technical Specifications , Security Firewall With 3Years Of Licence And 1500 Concurrent Users , Management Workstation Accessories As Per Specifications , Digital Signage Display Or Equivalent 75Inches As Per Technical Specifications , Management Laptop Accessories As Per Specifications , Patch Chords Machine Crimped As Per Technical Specifications , Table And Chairs 2 Nos As Per Specifications , Dc Control Accessories As Per Technical Specifications , 4Mp Ip Dome Camera Night Color Vision As Per Technical Specifications , 4Mp Ip Bullet Camera With Audio As Per Technical Specifications , Storage System For Cctv 45 Days Backup 300Tb Nas Orsan , Central Monitoring Software Licenses Vms , Camera Mounting Alignment Network Central Control Room Setup , 98-Inch Led Smart Interactive Display Android Based , High Resolution Auto-Focus Video Conferencing Camera With Essential Items , Computer Integrated Projector As Per Technical Specifications Total Quantity : 34749
Contract Date: Ref. Documents Contract Value : 3.94 Crore
Local Bodies No of Bidders 4
Contract Date: Ref. Documents Contract Value : 5.72 Lakh
Government Departments No of Bidders 7
Madhya Pradesh View Result →
Contract Date: Jun 15, 2026 Contract Value : 69,485
Government Departments No of Bidders 4
Contract Date: Jun 24, 2026 Contract Value : 88,870
Government Departments No of Bidders 3
20.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
21.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
22.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
23.
Educational and Research Institute #11047682 AOC
Supply Of It And Lab Equipment= 2 Computer Notebook Processor Make Intel/Amdprocessor Generation Min Intel 14Th Gen Core I5 / Amd Ryzen 5 8000 G Seriesnumber Of Cores Per Processor Min 4 Coreschipset Series Any Valuegraphics Type Integratedoperating System (Factory Pre-Loaded) Windows 11 Professional Type Of Ram Ddr5Ram Size (Gb) 8 Gb Minimumram Speed (Mhz) Min. 3200 Or Higherram Expandability Up To (Using Spare Dimm Slots In Gb) Min. 32 Gbcapacity Of Ssd (Gb) Min 512 Gb Ssdwireless Connectivity Integrated Gigabit Ethernetwi-Fi 6 Or Higher With Bluetooth Enabled 5.0 Or Higherled Backlight Monitor Size (Inches) Min 14 Inch With Integrated Cameradisplay Resolution (Pixels) Min. 1920 X 1080Panel Technology Ips/Tn/Wva Speaker, Wireless Connectivity, Ethernet Port 1 Qty, Bluetooth, Usb Port 2 Qty, Hdmi Port 1 Qty, Battery Warranty 5 Year, Web Camera Yeson-Site Oem Warranty 5 Year Onsite Oem Warrantyoem For Desktop Should Be Among The Listed Products In Gartner Magic Quadrant Or In Idc India Report During The Last 5 Years (In All Quarters) 3 Desktop Computer Processor Make Intel/Amdprocessor Generation Min Intel 14Th Gen Core I7 / Amd Ryzen 7 8000 G Seriesnumber Of Cores Per Processor Min 8 Coreschipset Series Compatible To The Required Configurationslots And Ports Minimum Requirement , Bidders Can Offer More As Per Their Product Designone Ethernet Rj-45One Display Portone Hdmione Audio Line Out3 Nos Usb 2.0 Ports4 Nos Usb 3.2 Ports (Including Type C)1 Pci Express X161 Pci Express X 11 M.2 Slots For Storagegraphics Type Integratedoperating System (Factory Pre-Loaded) Windows 11 Professional (Oem Declaration Regarding Genuine Activated Preloaded Windows 11 Professional) Type Of Ram Ddr5Ram Size (Gb) 16 Gb Minimumram Speed (Mhz) Min. 4800 Or Higherram Expandability Up To (Using Spare Dimm Slots In Gb) Min. 64 Gbcapacity Of Ssd (Gb) Min 512 Gb Ssdwireless Connectivity Integrated Gigabit Ethernetwi-Fi 6 Or Higher With Bluetooth Enabled 5.0 Or Highermonitor Size (Inches) Min. 23.8 Inch Or Higher And Should Be Same Oem For Which Desktop Is Offered, With Tco Certifieddisplay Resolution (Pixels) Min. 1920 X 1080Panel Technology Ips/Ledmouse Connectivity Wired Keyboard Connectivity Wired On-Site Oem Warranty 3 Year Onsite Oem Warrantycertification Bis, Ul, Rohs, Bee/Energy Star, Epr, Iso: 9001,Additional Requirement Bidder To Supply Factory Pre-Loaded Windows 11 Professional And Ms Office Academic Edition 2021 Along With Antivirus License Valid For 5 Years From Date Of Activation.Note: Licenses Of Software Shall Be Valid Till 5 Years Warranty. Bidder To Submit Confirmation From Microsoft To Supply Genuine License Software For All The Systems.Oem For Desktop Should Be Among The Listed Products In Gartner Magic Quadrant Or In Idc India Report During The Last 5 Years (In All Quarters)Audio With Built In Speaker In Monitor/Desktop 4 Computer Notebook Processor Make Intel/Amdprocessor Generation Min Intel 14Th Gen Core I7 / Amd Ryzen 7 8000 G Seriesnumber Of Cores Per Processor Min 8 Coreschipset Series Any Valuegraphics Type Integratedoperating System (Factory Pre-Loaded) Windows 11 Professional Type Of Ram Ddr5Ram Size (Gb) 16 Gb Minimumram Speed (Mhz) Min. 4800 Or Higherram Expandability Up To (Using Spare Dimm Slots In Gb) Min. 64 Gbcapacity Of Ssd (Gb) Min 512 Gb Ssdwireless Connectivity Integrated Gigabit Ethernetwi-Fi 6 Or Higher With Bluetooth Enabled 5.0 Or Higherled Backlight Monitor Size (Inches) Min 14 Inch With Integrated Cameradisplay Resolution (Pixels) Min. 1920 X 1080Panel Technology Ips/Tn/Wva Speaker, Wireless Connectivity, Ethernet Port 1 Qty, Bluetooth, Usb Port 2 Qty, Hdmi Port 1 Qty, Battery Warranty 5 Year, Web Camera Yeson-Site Oem Warranty 5 Year Onsite Oem Warrantyoem For Desktop Should Be Among The Listed Products In Gartner Magic Quadrant Or In Idc India Report During The Last 5 Years (In All Quarters) 5 Audio Visual Equipment Audio Visual Equipment In A Language Lab Enriching, Language Learning By Providing Engaging, Interactive, And Multi Sensory Experience 6 Recording Devices Recording Devices In A Language Lab Provide Valuable Opportunities For Listening, Speaking, Assessment, And Self Directed Learning They Enhance Language Acquisition By Offering Practice, Feedback, And Exposure To Authentic Language Content 7 Lcd Projector Type Of Display Poly Silicon Tft Active Matrixresolution 1024 × 768 Pixels (Xga) / 1280 × 800 Pixels (Wxga)Lens F= 1.80,Focal Length: 3.71 Mmcolor Reproduction Full Color, 16.77 Million Colorsbrightness Normal Power Consumption Mode:White Light Output 3100 Lumens (Iso 21118 Standard)Color Light Output 3100 Lumenseco Power Consumption Mode:White Light Output 1800 Lumens (Iso 21118 Standard)Contrast Ratio 3000 To 1 With Auto Iris On And Normal Power Consumption Modeimage Size 55.9 To 93.2 Inches (1.42 To 2.37 M)/ 60 To 100 Inches (1.52 To 2.54 M)Projection Distance 13.7 To 23.5 Inches (0.35 To 0.60 M)Projection Methods Front, Wall Or Ceiling-Mountedoptical Aspect Ratio(Width-To-Height) 4:3 Or Better Focus Adjustment Manualzoom Adjustment Digitalzoom Ratio(Tele-To-Wide) 1:1.35Internal Sound System 16 W Monauralnoise Level 35 Db (Normal Power Consumption Mode)28 Db (Eco Power Consumption Mode)Keystone Correction Angle Vertical: ± 5ºhorizontal: ± 5ºusb-B Port Compatibility Usb 1.1 And 2.0 Compliant For Usb Display Or External Mouseusb-A Port Compatibility One Usb 1.1 And 2.0 Compliant Port For Usb Device Input Or Epson Document Camera Display 8 Acoustic Panel1 Unit Type Piece2 Product Unit 100 Piece3 Color Black And White4 Product Type 3D Acoustic Wall Panel5 Application Floors & Roofs, Walls, Columns & Beams 9 Headphone, Microphone And Speaker Item Dimensions L Into W Into H7 Point 6 Into 4 Into 25 Point 8 Centimetresconnectivity Technology Wired 3 Point 5 Mmcolorblack 10 Upstechnical Specification Item Description Of Minimum Requirementrating In Kva (Kva) 2.0 Kvatechnology Igbt-Pwm With Or Without Inbuilt Isolation Transformerinput Power Single Phase 160V - 260V Signwave 50Hzinput Frequency Range 50 Hz +/- 6% Hzoutput Power Single Phase 230V +/-1%Output Frequency Range 50 Hz +/- 6% Hzout Wave Form Pure Signwavebackup Time (Minutes) Min. 60 Minutes On Full Loadminimum Vah (Vah) Min. Vah 3200Noise Level (1 Meter Distance Fro Ups) /=90%50% Overload Limit For Minimum 1 Minutes Yestotal Harmonic Distortion (Thd) (%) Maximum 3% 11 Multifunctional Laser Printer Printing Technology Lasercartridge Technology Cartridge Technology: Composite/ Separate Drum & Tonertype Of Printing Mono (Black Only), Duplexpaper Size A4/Legalduplexing Feature Yes For Both Print And Scanprint-Speed (A4) - Mono (Ppm) Min. 29 Ppm Or Higherscanning Feature Yesscan Auto Document Feeder Capacity Min. 30 Sheets Or Highermemory/Ram Size (Mb) Min. 256 Mb Or Highernetwork Connectivity Yestype Of Network Interface Ethernet 10/100Wireless Connectivity Yesno Of Paper Tray Min. 1Paper Tray Capacity Min. 150 Duty Cycle/Month (No Of Prints) Min. 20,000 Or Higher 12 Notice Board 3*4 Size Pinup Board 13 Sinewave Invertor 3 Kva With 150 Amp Tubular Battery With 2 Hr Backup Time Min 14 Led Screen 6X3 For Indoor 15 Led Screen 6X4 For Indoor 16 Digital Electronic Display Size 6*1.5 17 Bench Top Single Beam Uv Spectrophotometer 340-999 - Covers 190To 1100 Nm 4 Position Cuvette Holder Automatic Wavelength Selection 128X64 Graphical Lcd Printer Interface Usb Computer Interface With Professional Scanning Software Specifications : Wavelength Range : 190 - 1100Nm, Spectral Band Width : 18 Orbital Shaking Incubator: Size 580* 600 Mm Shaking Speed Range 20 To 250 Rpm Voltage 220-240V External Dimensions 800*1150*1300 Mm Chamber Volume 215 Ltrs 19 Manual Baby Mini Power Pack: Manual Bio World11 X 10 X 6 Cm (L X W X H)50 V100Ma 20 Mini Horizontal Gel Electrophoresis System: 1 Microtome Dimensions2. 300-400Mm3. Alloy Steel4. Min. 1Micron5. External Size 6.450Mm-350Mm 7.Thickness8.Max.60 Micron9.Trimming Thickness Range 10.10Um-40Um11.Vertical Stroke 21 Advance Rotary Microtomy (Latest Spencer ‘820’ Type ) (With Razer): 1. Microtome Dimensions2. 300-400Mm3. Alloy Steel4. Min. 1Micron5. External Size 6.450Mm-350Mm 7.Thickness8.Max.60 Micron9.Trimming Thickness 22 Compound Microscope: Type: Compound Microscopes.Head: Trinocular 30º. 360º Rotating. 48-75Mm Interpupilar. +/- 5Mm Diopter On Left Tube.Objective Magnification: Semi Plan 4X/0.10, 10X/0.25, S40X/0.65, Oil Immersion Objectives. 23 Laboratory Hot Air Oven: 1. Inner Size (Wxdxh)2.Heat Load3.0.75 Kw, 1.50 Kw, 2.25 Kw4.No. Of Shelves 2 5.Temperature Range 6.50Oc - 200Oc+/-2Oc 7.Insulation8.Mineral Wool9.Safety Device 10.Thermostat 11.Temperature Controller 12.Temperature Display13.By L-Shaped Glass Thermometer 14. Electrical Supply15. 220/230V Ac, 50/60Hz 24 Laboratory Eggs Incubator (Capacity 80 Lit):1.Temperature Range Ambient +5 To +90°C 2.Temperature Uniformity + / - 0.35°C At 37°C 3.Temperature Control Thermostat4.Display Thermometer5.Door Solid Door W/ Glass Window & Lock6.Exterior Ms Painted7.Interior Aluminum8.Safety Features Over-Temperature Thermostat9.Shelves Aluminum10.Power Supply 220 Volts 11. Optional - Caster Wheels12.Digital Timer 13.Fluorescent Lamp14. Incubation Of Co2 Air Mixture15.Combined Digital Temperature & Humidity Controller 25 Ph Meter (Digital) :1. Range Ph : 0 To 14Ph2. Mv Measurement : 0+/-1999 Mv3. Resolution Ph : 0.014. Accuracy Ph : 0.015. Calibration :Three Point Calibration6. Display : 4 Digit Led Display7. Power Supply: 230V Ac 50Hz +/- 10% 8.Temperature Range : 0 To 100 Degree C9. Standard Buffer Capsules : 4,7 &9.2Ph Buffer 4,7 &9.2 Supplied10. Operating Manual : Operating Manual 11.Electrode :1 Set Of Electrode, Stand & Clamp 26 Conical Flask 200 Ml :Insufficient Number Available 27 Electronic Balance : 1.Kern Pcb 6000-0Feature2.Ce Compliant Material3.Stainless Steel Platform4.Ac/Dc Input5.100 - 240 V Ac, Universal Plug Set 28 Gel Electrophoresis Assembly With Digital Power Pack :Dimension : 19.5Cm(L)X28.5Cm(B)X6.5Cm(H) Number Of Samples : 52Buffer Volume : 600Mlnumber Of Casting Tray :7X5Cm,13X6Cm,13X10Cm (1 No. Each) Number Of Combs : Multichannel Pipette Compatible Combs Height Adjustable Combs26-Wells 1.5Mm Thickness Comb (Well Width-3Mm,Interspace- 1.5Mm) (2 Nos.)No. Of Platinum Electrodes : Positive And Negative (Each One) Buffer Chamber With Safety Lid : 1 No.Gel Caster : 1 No. 29 Thermal Cycler :1.Europlug2.220-240 V, Europlug Feature3.Ce Compliant Usb Interface4.Eppendorf® 53840000125.Temp Measuring Range Accuracy: ±0.5 °C (At 20-45 °C) Parameter 6.24-100 °C Temp. Range7.300–1,500 Rpm Speed (Mixing)8. W × D × H 20.6 Cm × 30.4 Cm × 17.0 Cm9. Capacity 10 Holds 1 Block10.Stirrer Diam. 3 Mm Weight 6.3 Kg 30 Cooling Centrifuge :230 V Ac, Uk Plug Featurece Compliant To Hold 24 1.5/2.0 Ml Micro-Centrifuge Tubes Corning 6767-Hs Parameter 13300 Rpm16300 × G Technique(S) Centrifugation: Suitable L × W × H 23.5 Cm × 29.3 Cm × 21.6 Cm Weight 31 Gel Documentation Unit With Computer :64 Mega Pixel Camera 32 Micropipette :12 Channel10-100 Ltwelve Channel Variable Micropipette 0.5 Ml 33 Tips Of Micropipette :Round Polypropylene Tip100-1000Hl C3 Variable Volume Single Channel Micropipette Mechanical (02 Each) 34 Eppendorf Tubes :Safe Lock Tubes With Lid& Latch With Graduation Material Polypropylene(02 Each) 35 Pcr Tubes:Micro-Centrifuge Tube 0.2 Ml With Cap , Transparent , Pack Size - 1000 Pcs Thin-Wall Polypropylene Pcr Tubes With Attached Flip Caps For Labeling, Full-Height Wells. The Thin-Walled Polypropylene Tubes And Caps Have Tight Seals And Can Therefore Be Used For Low Reaction Volumes. 36 Deep Freezer: 1. Capacity Cooling (Ltrs) 5502.Temperature Range -18 Degree To -24 Degree C 3.Electrical Power Supply4.Electrical Power Supply Na5.Packing Delivery& Taxes 6.Capacity:527Liters. 7.Dimensions(Mm):920 8.Height X 1425 Width X 690 Depth 37 Laminar Air Flow :Material : Stainless Steel 38 Ph Meter1.Ph Range -2.00 To 16.00Ph.2.Big Screen & Large Lcd Display.3.With White Backlight.4.Memory - Up To 100 Readings.5.Usb Interface.6.0.01Ph Resolution.6. 3 Points Calibration 39 Soxhlet Apparatus With Heating Mantle:Item Weight 9 Kg 500 Gpackage Dimensions 67 X 34 X 31 Cm; 9.5 Kg 40 Autoclave :Surgical Sterilizer Aluminum Portable Auto Clave - 12X14 =24 Lt 41 Bottle Top Dispenser With Dual Inte Technology :Bottle Top Dispenser- Volume Range 0.5- 5 Ml Type Of Product : Ultimus Bottle Top Dispenser Coefficient Of Variation ±Ml 0.01 ±Mlambient Temperature : 20°C Increment : 0.1 Ml 42 Centrifuge :Item Weight 3 Kg 810 Gproduct Dimensions 20 X 21 X 26 Cm; 3.81 Kg Item Part Number Centfitem Height 26 Centimeters Item Width 21 Centimeters Wattage 150.00 43 Digital Chemical Balance :Surplus External Two Pan Laboratory Balance Weighing Scale Type- Bench Scale Material-Steelproduct Type Digital Analytical Balance Weighing Machine Monitor Display-Digitalpower Supply-Electric 44 Double Door Refrigerator :Net Total(Liter)322Net Width(Mm)600 Mmnet Case Height With Hinge(Mm)1715 Mmnet Depth With Door Handle(Mm)672 Mm Net Weight(Kg)59 Kg 45 D.O. Meter :Net Total(Liter)322Net Width(Mm)600 Mmnet Case Height With Temperature Range -5.0 To 50.0°C (23.0 To 122.0°F)Temperature Resolution 0.1°C (1°F)Temperature Accuracy ±0.2°C (±1°F) (Excluding Probe Error) Do Probe Hi 76407 With 4 M (13) Cable (Included)Automatic Shut-Off After Approx. 8 Minutesbattery Type/Life 1.5V Aa (4) / Approx. 500 Hours Of Use Environment 0 To 50°C (32 To 122°F); Rh Max 100% Dimensions 196 X 80 X 60 Mm (7.7 X 3.1 X 2.4 In.)Weight 500 G (1.1 Lb.) 46 Digital Ph Meter With Electrode (Lcd Display):1. Range Ph : 0 To 14 Ph2. Mv Measurement : 0+/-1999 Mv3. Calibration* :Three Point Calibration4. Buffer Recognition : Manual& Automatic5. Display : 4 Digit Led Display6. Parameters Displayed : Ph & Mv7. Power Supply : 230V Ac 50Hz +/- 10%8. Standard Buffer Capsules : 4,7 &9.2Ph Buffer 4,7 &9.2 Supplied9.Electrode :1 Set Of Electrode, Stand& Clamp 47 Digital Photoelectric Colorimeter :Type : Digital Photo Colorimeter Resolution : 0.01 Aabsorbance : 0- 1.99Aphoto Detector : Silicon Photodiode / Photo Cell Display : 2 Digit Led 48 Digital Potentiometer :Technical Specifications : Range 0 To  199.9 Mv 0 To  1999 Mv Resolution 0.1 Mv Repeatability  1 Mv Accuracy  1 Mv  1 Digit Operating Temperature 10 C To 45 C Display 3 Digit 0.5 Seven Segment Led Display With Auto Polarity Indication Power 230Vâ 10% Ac, 50 Hz. Dimensions 275 190 78Mm Weight2.5 Kg. (Approx) Standard Accessories Platinum Electrode : 1 No. Reference Electrode : 49 Distillation Apparatus:Spinning Band Typesteflon - Operates Up To 225 °C Stainless Steel – Operates Above 225 °C High Efficiency And High Temperature Bands Maximum Theoretical Plates Optional: 4 Place Or 8 Place Automatically Collect Fractions According To Vapor Temperature Vacuum Operation Optional Vacuum System 100-1 Mmhg Range Other Ranges Availableautomatic Control Of Vacuum Level. Vacuum Reduces Boiling Points. Ideal For Thermally Sensitive Samples Or High Boiling Materials Automatic Controller Provides Automatic Control Of The Entire Distillation Process Start The Distillation And Walk Away Pc Optional Control From Pc Perform A Distillation From A Pc Analyze Distillation Results Using Our “Data View” Program. Safety Marks Ce Marked Listed To Ul 6101.1 By Etl Listed To Csa C22.2 1010.1 By Etl C Tick (Australia/Nz)Safe For Laboratory Use Power (Distillation Unit Only) 1-22 Liter (115 V) 15 Amps 1-22 Liter (220 V) 8 Amps50 Liter (220V) 15 Amps Configured For Local Power Requirements And With Local Power Plug, 115 Or 220 V, 50/60Hz 50 Dryer And Temperature Controller :Applicationair Dryer & Freezers. General Specificationstemperature Range -50°C To 99°C.230Vac Standard. Other Models With 12Vdc, 24Vdc, 110Vac On Request. Panel Cutout: 29 X 71 Mm. Screw Terminals: Admit 1X2.5 Mm2 Wires. 51 Blower :Item Weight: 850 Gitem Dimensions Lxwxh: 20 X 40 X 20 Centimetres Net Quantity: 1 Countgeneric Name: Electric Air Blower 52 Chemical Thermometer :Included Components Thermometer Outer Material Glassspecification Met Ce Display Type Analogitem Length 30 Centimetersupper Temperature Rating 300 Degrees Celsius Response Time 500 Millisecondsreusability Reusableimmersion Depth 30 Centimeters 53 Calorie Meter Working (Operating) Temperature 15-70°Cresults Per Hour 10 Samples Per Hour Using 2 Oxygen Bomb Vesselsmeasuring Range Max 99Mj, 99,000,00 Joules Working Temperature Min 1°Cworking Temperature Max 50°C Oxygen Operating Pressure Max 40 Barbalance/Scale Interface Rs232, 1200 To 38400 Baud (Settable) 54 Beaker- 50Ml, 100Ml, 250Ml, 500Ml, And 1000Ml, Catering To Various Volume Crafted From High-Quality 3.3 Borosilicate Glass, The Low- Form Design With A Wide Base And Tapered Spout. 55 Funnel :A 125Mm Length Stem. Stem Has Diameter Measuring 16Mm. 56 Pipette :Laboratory Application Area, India Country Of Origin, 915 Mm Overall Length, Twisted Galvanized Iron Wire Material, 1 Pc Pack Of, Hard Nylon Bristles, 150X25 Mm Head Size. 57 Burette :Accuracy As Per Din Iso 385 Standardglass Key, 50 Ml Burette, Borosilicate Glass 3.3 Class-A, White Graduation 58 Burette Stand :Dimension Of Base: 300X150X30Mm. Rod: 700X10Mm. 59 Mortar Pestel:125Ml Capacity And Is 85 Mm In Diameter. The Pestle Is 95 Mm Long 60 Electronic Balance :Single Pan Balance 5 Weighing Capacity: 220 Gm Or More 6 Pan Size: 90 Mm In Diameter Or More 7 Display Readability : 0.1 Mg Or Less 8 Weighing Repeatability: +/- Transparent Three Door Draft Shield- Top As Well As Sides Sliding 17 Input Power Supply Requirements: 240 V 61 Burette Brush :915 Mm Overall Length, Twisted Galvanized Iron Wire Material, 1 Pc Pack Of, Hard Nylon Bristles, 150X25 Mm Head Size 62 Test Tube Brush :High Quality - Made Of Stainless Steel And Nylon Bristles Due To Which Easy To Clean, Will Not Rust. Durable, Strong But Soft Nylon Bristles For Cleaning. This Test Tube Brush Is Specialized Designed For Cleaning Bottle Neck Flasks. 63 Conical Flask :High Quality, Borosilicate 3.3 Glass Conical Flasks Lab Grade & Tested Glass 50 Ml Capacity 64 Volumetric Flask : Capacity Sg-100: 100Ml Sg-250: 250Ml Sg-500: 500Ml Sg-1000: 1,000Mlmaterial Glass Heat Resistance With Graduation 65 Wire Gauze: 120Mm*120Mm 66 Round Bottomed Flask Borosilicate Glass Is Type Of Glass With Silica And Boron Trioxide. Capacity 100 Ml Non Toxic 67 Periodic Table (Poster)140*100Cm 68 Gas Connection And Fitting In New Lab 250 Ft Gas Pipe Line With Rubber Pipe-100 Metre, Burner Brass- 48, Brass Gas Top Two Way 24, Copper Pipe-24 Copper Hos Pins- 24 Brass Line Volwes All With Isi Mark & Installation 69 Water Bath Digital :Water Bath With Selectable Openings 304 Stainless Steel 0.01.Resolution Electric Constant Temperature Water Bath For Lab Commerical.110V - 220V Lxt Panda Lxt Panda Digital Lab Water Bath, Thermostatic Water Bath With Selectable Openings 304 Stainless Steel 0.01.Resolution Electric Constant Temperature Water Bath For Lab Commerical.110V - 220Vless 70 Digital Ph Meter Range 015 Calibration-Ph Ut To 3 Pointtemperature Range 0 To 100C 71 Digital Blood Pressure Machine 1. A Digital Automatic Blood Pressure Monitor, Designed For Accurate And Convenient Monitoring Of Blood Pressure Levels At Home Or In A Clinical Setting.2. The Monitor Features A Large, Easy-To-Read Digital Display Screen That Shows Blood Pressure Readings. 72 Blower :Item Weight: 850 Gitem Dimensions Lxwxh: 20 X 40 X 20 Centimeters Net Quantity: 1 Countgeneric Name: Electric Air Blower 73 Single Needle Lock Stitch Sewing Machine : A3B Needle – Db×1 11-18# Auto Cutter – Yes Auto Reverse – Yes Thread Number – 2 Stitch Length (Mm) – 5 Height Of Pressure Foot – 5-13 Sewing Speed – 5000 Spm (Stitch Per Minute) A/M – Yes Volume (Mm) – 671 X 248 X 550 Power Consumption – 220 V Lubrication – Fully Automatic Lubrication 74 Over Lock /Inter Lock Sewing Machine :1.Application : Suitable For Light To Medium Fabric2.Stitch Type : Chain Stitch3.Needle Light : Led Type-3 Step 4.Differential Feed Ratio : 0.7 ~2.05.Needle System / Size : Dcx1# 9~146.Nos Of Loopers : 27.Nos Of Thread : 4 8.Lubrication Type : Automatic9.Stitch Length : 3.6 Mm10.Stitch Width : 4/6 Mm11.Feed Type : Differential 12.Pressure Foot Height : 5 Mm13.Up / Down Needle Position : Yes14.Sewing Speed Adjustments : Yes
Contract Date: May 18, 2026 Contract Value : 1.46 Crore
Local Bodies No of Bidders 4
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 4.87 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 8
29.
Educational and Research Institute #10815224 Price Bid
Procurement, Installation And Maintenance Of Infrastructure And Communication Technology (Ict) Equipment And Consumables Procurement, Installation And Maintenance Of Infrastructure And Communication Technology (Ict) Equipment And Consumablesprabodhini College, Porvorim, Goa. , Category 2: Ict Equipment’S Estimated Cost:59,88,000 /- , Digital Metal Podium Powder-Coated Metal Cabinet, Free-Standing, With Lockable Caster Wheels For Mobility; Crca Steel ~1.6 Mm Thick; Metal Top; Locking Security System; Storage Space For Cpu, Keyboard & Mouse, Laptop Trays, Side Shelf, 21.5? Interactive Touch Monitor; Motorised Tiltable Monitor Mechanism; Scratch-Resistant, Anti-Glare Screen; Full Hd (1920×1080) Resolution; Supports Finger & Stylus Input; Annotation Software Capabilities, Built-In 120 W Rms Amplifier; Two 30 W Wall Speakers; Two Gooseneck Microphones; One Wireless Handheld Mic; One Wireless Collar Mic; The Usual Av Input/Output (Vga, Hdmi, Usb, Aux, Xlr, Etc., Cpu: Intel I5; Ram 8 Gb; Storage: 500Gb Hdd; Wifi And Bluetooth; Includes Keyboard & Mouse., Vga, Hdmi, Usb, Aux, Xlr; Rj-45 Lan Port; Vga/Hdmi Switcher; Front Panel “Source” Control; Power Sockets Etc., Dimensions: 28? X 22? X 47? (L × W × H) ; Weight ~ 80 Kg, Minimum 1 Year Warranty , Smartboards Preffered Make:Viewsonic/Samsung/Solitaire Panel Size: 75,Type/Tech: Ips Type,Display Area (Mm): Minimum 1650.24(H) × 928.26(V),Aspect Ratio: 16:9,Native Resolution: 4K60hz,Colours: 10 Bits,Brightness: Minimum 450 Nits Or Higher,Contrast Ratio: 1200:1 (Typ) 5000:1 (Dcr) Or More,Response Time: 8Ms Or Better,Viewing Angles: H = 178, V = 178 Typ.,Backlight Life: Minimum 50,000Hr Of Higher Surface Treatment: Hardness: 9H Or Higher,Thickness: 4Mm,Orientation: Landscape,Processor: Octa Core Arm Cortex-A73*4 + A53 * 4 Or Higher,Android 11.0 And Upgarade To 13,Ram: 8Gb Ddr4 Or More,Storage: 64Gb Or More Type/ Tech: Ir Recognition/ P-Cap,Touch Point: 40 Points Or Higher,Hdmi In: Minimum 3,Rs232: X1,Ops: 1 Audio Out: 3.5Mm X1,Spdif: X1, Rj45: X2,Type A: Usb 2.0 X2, Usb 3.0 X4 “Smartport Usb” To All Channels,Type B: X2, For Touch,Type C: X1 (Dp 1.2, Usb2.0, Pd65w, Ethernet 100M),Speakers: 12W X 2 + 16W X 1 Or More Light Sensor : Yes,Power Consumption: 140W Or Less,Eye Care Certification Like Low Blue Light & Flicker Free Certifications: Tuv, Fcc, Energy Star 8, Emc/Ce, Cb, Rohs & Doc, Reach Test Report, Weee Test Report, Bis, Epat Software Features: Entity Management & Device Manager To Manage Ifp Remotely Without Lan, Also To Share Content & Broadcast Messages Remotely Onto Ifps,Same Whiteboard Software For Windows, Android & Browser,Live Webcast Directly From Interactive Whiteboard Software To Youtube And Facebook, Screen Recording,Artificial Intelligence Pen,Wireless Casting On Ifp From Mobile & Laptop,Drag And Drop Youtube Videos, Direct Images From Google Search,Handwriting Recognition Text To Speech Inbuilt In Whiteboard Software (Male Or Female Voice),Create Online Quiz With Time Limit From Whiteboard Software,Auto Grading Of Answers,Download Results As Excel Sheets,Sign In Directly From Qr Code On Interactive Whiteboard Software And Link Cloud Storages (Google Drive, Microsoft One Drive, Box Or Drop Box),4K Ops Module With Intel Core I5 Or Better, 8 Th Generation Or Better, 8 Gb Ram 256Gb Ssd Or Better. Ops Secification: 4K Ops Module With Intel Core I5 Or Better, 8 Th Generation Or Better, 8 Gb Ram 256Gb Ssd Or Better. Additional: Latest Microsoft Office And Ups , Video Conferencing Equipment- Webcamera Along With Wireless Speaker And Bluetooth Dongle Microphones For Large Classroom Setup- Evota Ultra-Wide 4K Resolution Camera For High-Definition Video Capture, Hd Support, Built In Microphone, And Microphone Wireless Speaker Phone With Bluetooth Dongle, Speaker Output, Ai Noise Reduction, 8 Mic Array, Built In Dsp,High-Quality Audio Output Suitable For Conference Or Meeting Rooms,Plug-And-Play Support , Camera And Lens- Preffered Make:Canon, Nikon Sensor: 24.2Mp Full-Frame Cmos Sensor,Processor: Digic X,Iso Range: 100–102,400 (Expandable To 50–204,800) Autofocus: Dual Pixel Cmos Af Ii With Up To 1,053 Af Points,Continuous Shooting: Up To 40 Fps With Electronic Shutter,Viewfinder: 2.36M-Dot Oled Evf,Display: 3.0 Vari-Angle Touchscreen Lcd With 1.62M Dots,Video: 4K Uhd At 60P, 10-Bit 4:2:2, Connectivity: Wi-Fi, Bluetooth, Uvc/Uac For Webcam Use Lens Format: Full-Frame,Focal Length: 24–105Mm,Aperture: F/4–7.1,Image Stabilization: Up To 5 Stops,Autofocus: Stm Stepping Motor For Smooth And Quiet Focusing,Macro Capabilities: Center Focus Macro With 0.5X Magnification,Minimum Focusing Distance: 0.66 Ft (0.20 M) In Autofocus; 0.43 Ft (0.13 M) In Macro Mode,Filter Size: 67 Mm , Dual-Channel Wireless Microphone System System Type: Dual-Channel Wireless Microphone System With One Receiver And Two Transmitters. Microphone Type: Built-In Omnidirectional Microphones In Each Transmitter; Supports External Lavalier Microphones Via 3.5Mm Trs Input. Transmission Technology: Series Iv 2.4Ghz Digital Transmission With 128-Bit Encryption. Transmission Range: Up To 200 Meters (Line Of Sight). Frequency Response: 50Hz – 20Khz. Maximum Spl: 100 Db Spl (1Khz @ 1M). Battery Life: Up To 7 Hours On A Full Charge. Charging Port: Usb Type-C. , Wireless Connectivity- Wifi Routers Wifi Routers- Tplink Archer C6 Dual Band Router,Dual-Band Wi-Fi: Supports Both 2.4 Ghz And 5 Ghz Frequencies , All In One Pcs Preffered Make: Hp / Dell /Lenovo I5- 13Th Gen 1355U Or Above,8 Gb ,512 Gb ,23.8 Diagonal, Fhd (1920 X 1080), Ips, Anti-Glare, Wled-Backlit, 250 Nits, 72% Ntsc,Win 11 Pro,Intel® Uhd Graphics; Intel® Iris® X? Graphics; Intel® Graphics,Wired,Microsoft Office 21 Or Above 3 -Years , Video Camcorder- Preffered Make:Canon, Sony 4K Uhd Recording,1/2.3 Cmos Sensor,Digic Dv 6,Mp4 And Xf-Avc (Mxf),4K Uhd (3840 X 2160) At Up To 30 Fps,Full Hd 1080P At Up To 60 Fpsuhd 4K Camcorder, Xf-Avc: Up To 160 Mbps,Mp4: Up To 150 Mbps,Iso/Gain: 0 To 24 Db,F/1.8 To F/2.8,Up To 800X,5-Axis Dynamic Is (Optical + Digital),2 X Xlr Terminals (With Phantom Power),3.5Mm Stereo Mini-Jack,16-Bit/48Khz Linear Pcm And Aac,Headphone Output, Lcd Screen,Touchscreen, Usb-C: Supports Uvc For Livestreaming,Hdmi Output: Mini-Hdmi 2.0, Recording Media: Dual Sd/Sdhc/Sdxc Uhs-I Slotsheavy Duty Tripod Stand For Video Camera , Drone- Weight: < 249 G Flight Time: Min 34–45 Minutes Camera: 1/1.3 Cmos, 48 Mp, 24 Mm F/1.7 Lens Video: 4K Up To 100 Fps, 1080P Slow-Motion Up To 200 Fps, 150 Mbps Bitrate Photo Formats: Jpeg, Raw (Dng) | Video Formats: Mp4, H.264/H.265, Supports Vertical Video Capture, Panorama Modes: Sphere, 180°, Wide Angle, Vertical, Remote Controller- 5.5-Inch Fhd Screen With A Resolution Of 1920×1080 Pixels, 60Hz Refresh Rate, And 700 Nits Brightness. Supports 10-Point Multi-Touch,Up To 1080P/60Fps Live Feed When The Aircraft Is In Photo Or Video Mode,4 Antennas, 2T4r (Two Transmitters, Four Receivers), Two Built-In Antennas And Two External Antennas With Manual Angle Adjustments For Optimal Video Transmission,Supports Quick Charging , Copier Machine: Preffered Make: Canon, Xerox, Ricoh Main Unit -Machine Type-A3 Monochrome Laser Multifunctional; Core Functions-Print, Copy, Scan, Send And Optional Fax; Processor Speed 1.6Ghz Dual Core Processor; Control Panel Standard: 7 Inch Tft Lcd Wvga Colour Touch Panel; Memory Standard: 2.0Gb Ram; Storage Standard: 64Gb Emmc,Optional: 256Gb Ssd; Interface Connection- Network Standard: 1000Base-T/100Base-Tx/10-Base-T, Wireless Lan (Ieee 802.11 B/G/N), Wi-Fi Direct Connection Others Standard: Usb 2.0 (Host) X2, Usb 2.0 (Device) X1; Paper Input (Standard); Paper Supply Capacity (A4, 80 Gsm)-Standard: 1,200 Sheets Maximum: 2,300 Sheets (With Cassette Feeding Unit-Aw1); Paper Output Capacity (A4, 80 Gsm)-Standard: 250 Sheets Maximum: 645 Sheets (With Inner Finisher-L1 And Copy Tray-T2); Finishing Capabilities -Collate, Group, Offset, Staple, Hole Punch, Eco Staple, Staple On Demand; Supported Media Types- Main Body Cassette (Upper/Lower): Thin, Plain, Recycled, Color, Heavy, Bond, Pre-Punched, Letterhead, Postcard Multi-Purpose Tray:Thin, Plain, Recycled, Color, Heavy2, Bond, Pre-Punched, Letterhead, Postcard, Labels, Coated, Tracing;Supported Media Sizes-Upper Cassette: Standard Size: A4, A5, A5r, A6r, B5custom Size: 105.0 X 148.0 Mm To 297.0 X 215.9 Mm Lower Cassette: Standard Size: A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r, Com 10 No. 10*, Monarch*, Dl* Custom Size: 105 X 148 Mm To 304.8 X 457.2 Mm; Supported Media Weights -Main Body Cassette (Upper/Lower): 52 To 256 Gsm Multi-Purpose Tray: 52 To 300 Gsm Duplex: 52 To 220 Gsm; Warm-Up Time -4 Seconds Or Less From Sleep Mode: 10 Seconds Or Less From Power On: 10 Seconds Or Less; Dimensions (W X D X H)- 565 X 687 X 891 Mm; Installation Space (W X D)-1,286 X 1,116 Mm (With Dadf-Ba1 + Inner Finisher Tray Max Extended + Copy Tray-T2 Max Extended + Paper Cassette Opened; Weight -Approx. 66 Kg Print Specifications-Print Speed:Up To 45 Ppm (A4, A5, A5r, A6r), Up To 22 Ppm (A3), Up To 32 Ppm (A4r),Print Resolution (Dpi):Up To 1200 X 1200;Page Description Languages;Standard: Ufrii, Pcl6, Optional: Adobe Postscript 3Tm; Double-Sided Printing: Yes; Direct Print: Pdf, Eps, Tiff/Jpeg, Xps; Mobile / Cloud Printing: Airprint, Mopria, Canon Print Business, Uniflow Online And Universal Print By Microsoft; Fonts : Ps Fonts: 136 Roman Pcl Fonts: 93 Roman, 10 Bitmap Fonts, 2 Ocr Fonts, Andalé Mono Wt J/K/S/T (Japanese, Korean, Simplified And Traditional Chinese) , Barcode Fonts Print Features: Secure Print, Secure Watermark, Header/Footer, Page Layout, Duplex Printing, Mixed Paper Sizes/ Orientations, Toner Reduction, Poster Printing, Forced Hold Printing, Print Date, Scheduled Printing, Printing Using A Virtual Printer Operating Systems :Ufrii: Windows 10/11/Server2012/Server2012 R2/Server2016/Server2019/Server2022, Mac Os X (10.13 Or Later) Pcl: Windows 10/11/Server2012/Server2012 R2/Server2016/Server2019/Server2022 Ps: Windows 10/11/Server2012/Server2012 R2/Server2016/Server2019/Server2022, Mac Os X (10.13 Or Later) Ppd: Windows 10/11, Mac Os X (10.13 Or Later) Copy Specifications :Copy Speed Up To 45 Ppm (A4, A5, A5r, A6r), Up To 22 Ppm (A3), Up To 32 Ppm (A4r),First-Copy-Out Time:5.3 Seconds; Copy Resolution (Dpi):600 X 600; Multiple Copies: Up To 999 Copies; Copy Density: Automatic Or Manual (9 Levels); Magnification:25% - 400% (1% Increments); Preset Reductions: 25%, 50%, 70%, 100% (1:1), 141%, 200%, 400%; Preset Enlargements:25%, 50%, 70%, 100% (1:1), 141%, 200%, 400%; Basic Copy Features: Preset R/E Ratios By Area, Two-Sided, Density Adjustment, Original Type Selection, Interrupt Mode, Book To Two Pages, Two-Sided Original, Sort, Job Build, N On 1, Different Size Originals, Sharpness, Erase Frame, Copy Id Card, Skip Blank Pages, Free Size Original, Color Mode, Reserved Copy, Copy Sample; Scan Specifications:Type: Color Scanner; Pull Scan Specifications: Colour Network Scangear2. For Both Twain And Wia Supported Os: Windows 10/11/Server2012/Server2012 R2/Server 2016/Server 2019/Server2022; Scan Resolution (Dpi): Scan For Copy: 600 X 600 Scan For Send: (Push) 600 X 600 (Smb/Ftp/Webdav/Ifax), (Pull) 600 X 600 Scan For Fax: 600 X 600; Document Feeder Paper Capacity (80 Gsm): Up To 100 Sheets; Acceptable Originals/Weights: Platen: Sheet, Book, 3-Dimensional Objects Document Feeder Sheet Media Weight : 1-Sided Scanning: 38 To 128 Gsm (Bw), 64 To 128 Gsm (Cl) 2-Sided Scanning: 50 To 128 Gsm (Bw), 64 To 128 Gsm (Cl); Supported Media Sizes: Platen: Max. Scanning Size: 297.0 X 431.8 Mm Dadf: A3, A4, A4r, A5, A5r, B4, B5, B5r, B6, Custom Size: 139.7 X 128.0 Mm To 297.0 X 431.8 Mm; Scan Method:Push Scan, Pull Scan, Scan To Network, Scan To Usb Memory Key, Scan To Mobile Device, Scan To Cloud-Based Services (Uniflow Online); Scan Speed:1-Sided Scanning: 70/70 (300 X 300 Dpi, Send), 51 /51 (600 X 600 Dpi, Copy) 2-Sided Scanning: 35/35 (300 X 300 Dpi, Send), 25.5 /25.5 (600 X 600 Dpi, Copy); Double-Sided Scanning: Yes;Supported Media Sizes: Platen: Max. Scanning Size: 297.0 X 431.8 Mm Dadf: A3, A4, A4r, A5, A5r, B4, B5, B5r, B6, Custom Size: 139.7 X 128.0 Mm To 297.0 X 431.8 Mm; Scan Method:Push Scan, Pull Scan, Scan To Network, Scan To Usb Memory Key, Scan To Mobile Device, Scan To Cloud-Based Services (Uniflow Online); Scan Speed:1-Sided Scanning: 70/70 (300 X 300 Dpi, Send), 51 /51 (600 X 600 Dpi, Copy) 2-Sided Scanning: 35/35 (300 X 300 Dpi, Send), 25.5 /25.5 (600 X 600 Dpi, Copy); Double-Sided Scanning: Yes; Send Specifications- Optional / Standard-Destination: Standard: E-Mail/Internet Fax (Smtp), Smb3.1.1, Ftp, Webdav,Optional: Super G3 Fax;Address Book / Speed Dials: Ldap (2,000)/ Local (1,600) /Speed Dial (200); Send Resolution (Dpi):Push: Up To 600 X 600 Pull: Up To 600 X 600; Communication Protocol: Ftp (Tcp/Ip), Smb3.1.1 (Tcp/Ip), Webdav Email/Ifax: Smtp(Send), Pop3(Receive); File Format: Standard: Tiff (Mmr), Jpeg Pdf (Compact, Searchable, Pdf/A-1B, Encrypted), Xps(Compact, Searchable), Pdf/Xps (Device Signature, Office Open Xml (Powerpoint, Word) Optional: Pdf (Trace & Smooth), Pdf/Xps (User Signature); Universal Send Features:Original Type Selection, Two-Sided Original, Book To Two Pages, Different-Size Originals, Density Adjustment, Sharpness, Erase Frame, Job Build, Delayed Send, Preview, Job Done Notice, File Name, Subject/Message, Reply-To, E-Mail Priority, Tx Report, Original Content Orientation; Fax Specifications- Optional; Modem Speed: Super G3: 33.6 Kbps G3: 14.4 Kbps; Compression Method: Mh, Mr, Mmr, Jbig; Resolution (Dpi):200X100dpi (Standard), 200X200dpi (Fine), 200X400 Dpi (Super Fine), 400X400 Dpi (Ultra Fine); Sending/Receiving Size: Sending: A3, A4, A4r, A5*1, A5r*1, B4, B5*2, B5r*1 Receiving: A3, A4, A4r, A5r, B4, B5, B5r *1 Sent As A4. *2 Sent As B4 Short.; Fax Memory: Up To 30,000 Pages (2,000 Jobs); Fax Features:Senders Name (Tti), Selecting The Telephone Line (When Sending Fax), Direct Send, Delayed Send, Preview, Finished Stamp, Job Done Notice, Tx Report, Interrupt Transmission, Sequential Broadcasting, Password/Sub-Address Sending, Confidential Mailbox Store Specifications- Memory Media: Standard: Usb Memory, Security Specifications; Authentication & Access Control: User Authentication(Picture Login, Picture And Pin Login, Username And Password Login, Function Level Login, Mobile Login), Department Id Authentication(Depertment Id And Pin Login, Function Level Login), Uniflow Online (Pin Login, Picture Login, Picture And Pin Login, Card Login, Card And Pin Login, Username And Password Login, Depertment Id And Pin Login, Function Level Login), Access Management System(Access Control);Network Security:Tls 1.3, Ipsec, Ieee802.1X Authentication, Snmpv3, Firewall, Functionality(Ip/Mac Address Filtering), Wpa3 Support (Wi-Fi), Dual Network Support(Wired Lan/Wireless Lan, Wired Lan/Wired Lan), Enabling/Disabling(Network Applications, Remote Ui, Usb Interface), G3 Fax Separation From Lan, Usb Port Separation From Lan, Scan And Send -Virus Concerns For E-Mail Reception Document Security -Print Security(Secure Print, Encrypted Secureprint, Forced Hold Printing, Uniflow Secure Print 1),Receive Data Security(Confidential Fax Inbox Forwarding Received Documents Automatically), Scan Security (Encrypted Pdf, Device Signature Pdf/Xps, User Signature Pdf/Xps112), Send Data Security(Setting For Requesting Password Input Per Transmission, Restricted E-Mail/File Send Functions, Confirming Fax Number, Allow/Restrict Fax Driver Transmissions, Allow/Restrict Sending From History, S/Mime Support) Environmental Specifications- Operating Environment: Temperature: 10 To 30 °C (50 To 86 °F);Humidity: 20 To 80 % Rh (Relative Humidity); Power Source: Eur: 220-240V 50/60Hz 10A; Power Consumption: Maximum: Approx. 1,500W,Copying (With Dadf Continuous Scan): Approx. 666W (220-240V)*1,Standby: Approx. 28.1W (220-240V)*1,Sleep Mode: Approx. 0.8W*2,* 0.8W Is Not Available In All Circumstances Due To Certain Settings.,*1 Reference Value: Measured One Unit,*2 0.8W Is Not Available In All Circumstances Due To Certain Settings.,Typical Electricity Consumption (Tec): 0.48 Kwh*,*As Per Energy Star Version 3.0 Software & Printer Management- Tracking & Reporting: Uniflow Online; Remote Management Tools: Iw Enterprise Management Console Emaintenance Content Delivery System; Scanning Software: Network Scangear;Toner Cartridge/S: Toner C-Exv 67 Black; Toner Estimated Yield:33,000 Pages (A4), (Estimated @ 6% Coverage); Cassette Feeding Unit:Cassette Feeding Unit-Aw1: Paper Capacity: 550 Sheets X 2 (1,100 Sheets) (80 Gsm), Paper Type: Thin, Plain, Recycled, Color, Heavy, Bond, Transparency, Pre-Punched, Letterhead Paper Size: A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r,Custom Size: 105.0 X 148.0 Mm To 304.8 X 457.2 Mm,Paper Weight: 52 To 256 Gsm,Power Source: From The Main Unit Dimensions (W X D X H): 565 X 635 X 248 Mm,Weight: Approx. 16.0 Kg Output Options- Copy Tray: Check For Impacted Products.; Copy Tray:Inner 2Way Tray-M1:Tray Capacity (With 80 Gsm Paper):Upper Tray: Sra3, A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r: 100 Sheets,Lower Tray (Standard Tray): A4, A5, A5r, A6r, B5, B5r: Up To 250 Sheets,Sra3, A3, A4r, B4: Up To 100 Sheets Paper Weight: 52 To 300 Gsm, Dimensions (W X D X H): 428 X 405 X 88 Mm,Weight: Approx. 0.7 Kg, Inner 2-Way Tray-Copy Tray-T2:Capacity (80Gsm Paper):A4, A5r, B5, B5r: 100 Sheets,A3, A4r, B4: 65 Sheets,Dimensions (W X D X H): 444 × 373 × 176 Mm (Attached To The Main Unit, When The Extension Tray Is Extended),Weight: 0.5 Kg, Inner Finisher - Inner Finisher-L1:Upper Tray: Sra3, A3, A4, A4r, A5, A5r, A6r, B4, B5, B5r: Approx. 45 Sheets,Lower Tray: A4, A5, A5r, B5: Approx. 500 Sheets Sra3, A3, A4r, B4, B5r: 250 Sheets,A6r: 30 Sheets,Envelope: 10 Sheets Paper Weight: 52 To 300 Gsm,Staple Position: Corner, Double,Staple Capacity: A4, B5: 50 Sheets (52 To 90 Gsm),A4r: 40 Sheets (52 To 90 Gsm),A3, B4: 30 Sheets (52 To 90 Gsm),Eco Staple: A3, A4, B4, B5: 10 Sheets (52 To 64 Gsm)/8 Sheets (65 To 81.4 Gsm)/6 Sheets (82 To 105 Gsm),Staple On Demand: Approx. 40 Sheets (80 Gsm) Dimensions (W X D X H): 727 × 525 × 225 Mm (Attached To The Main Unit, When The Extension Tray Is Extended),Weight: Approx. 9.1 Kg Hardware Accessories- Card Readers: Ic Card Reader Attachment-B4 Attachment Kit For Reader-A2; Print Accessories- Pcl International Font Set-A Ps Printer Kit-Bt1; Send Options: Universal Send Trace & Smooth Pdf Kit-A1 Universal Send Digital User Signature Kit-C1; Barcode Printing: Barcode Printing Kit-D1; , Audio Accessories-Ahuja Wired Mikes , Audio Accessories-Ahuja Cordless Mikes , Audio Accessories-Mike Stand (Tall And Small), , Audio Accessories-Cordless Mike Holder Cap, , Audio Accessories-Wired Mike Holder Cap , Audio Accessories-Jack To Jack Wired , Audio Accessories-3 Pin Xlr Male To Xlr Female , Audio Accessories-Universal Aaa And Aa Battery Recharger Adapter , Audio Accessories-Aa Recharge Batteries, Aaa Recharge Batteries , Audio Accessories-Mains Power Cable Cords
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 3
30.
Health and Family Welfare #10796649 AOC
Tender for Tender For The Supply, Installation, Testing And Commissioning Of Unified Treat Management System (Utm) Firewall (Upgradation) And Implementation Of Advanced Anti-Virus Software In The Local Area Network In Mcc (Pgiosr) , Rate For The Supply, Installation, Testing And Commissioning Of Unified Treat Management System (Utm) Firewall With More Than 1000 User Capacity Including 3 Year Warranty (Upgrading Existing Utm Firewall) , Camc Of Unified Treat Management System (Utm) Firewall With More Than 1000 User Capacity Including Subscription, License, Upgradation Charges-4Th Year , Camc Of Unified Treat Management System (Utm) Firewall With More Than 1000 User Capacity Including Subscription, License, Upgradation Charges-5Th Year , Rate For The Supply, Installation, Testing And Commissioning Of Advanced Antivirus Software For Desktop/Laptop/Workstations (Including 3 Year Warranty) , Camc Of Advanced Antivirus Software For Desktop/Laptop/Workstations Including Subscription, License, Upgradation Charges-4Th Year , Camc Of Advanced Antivirus Software For Desktop/Laptop/Workstations Including Subscription, License, Upgradation Charges-5Th Year , Rate For The Supply, Installation, Testing And Commissioning Of Advanced Antivirus Software For Server Machines (Including 3 Year Warranty) , Camc Of Advanced Antivirus Software For Server Machines Including Subscription, License, Upgradation Charges-4Th Year , Camc Of Advanced Antivirus Software For Server Machines Including Subscription, License, Upgradation Charges-5Th Year
Contract Date: Mar 12, 2026 Contract Value : 43.51 Lakh
Private Organizations No of Bidders 2
Contract Date: Feb 20, 2026 Contract Value : 1.36 Lakh
Government Departments No of Bidders 2
32.
Public Administrative Department #10774531 Price Bid
Tender for e-library work in the old Panchayat building in village Khedli. - Supply, Installation, Testing And Commissioning Work Of Establishment Of Digital Library In Selected Schools Of Alwar District Area , Supply, Installation, Testing And Commissioning Of Master Desktop Having Feature Of Processor: Intel Core I5 12Th Generation 12500 Or Higher/ Amd Ryzen 5 5000 Series Or Higher, 6 Cores, Minimum 2.5Ghz Base Frequency; Chipset: Oem Compatible Chipset; Graphics: Integrated Hd Graphics; Memory (Ram): 16 Gb Ddr4 Ram 3200 Mhz Expandable Up To 64 Gb With Min 2 Dimm Slots; Storage: 1Tb Ssd Or Higher; Ports: 6 Usb Ports (Minimum 2 X Usb 3.0 Ports) Or Better, Hdmi Port, Display Port, Rj45, Universal Audio Jack, 4 X Sata Ports, 3 X Pci/ Pcie Slots; Wireless: Wi-Fi, Bluetooth; Audio: High- Definition Audio; Display: 21.5 Led Display With 1920 X 1080 Resolution Or Better, Tco 8.0 Or Higher (Same Make As Pc); Keyboard & Mouse: Oem Usb Keyboard & Oem Optical Scroll Mouse (Same Make As Pc); Form Factor: Small Form Factor With Tool Less Chassis Not More Than 10 Liters; Operating System: Pre- Loaded Windows 11, Certified From Supplied Os (Bid Specific Maf Require On The Name Of Oem For Preloading Windows); Security: Product Supplied Should Be With Tpm 2.0; Other , Supply, Installation, Testing And Commissioning Of Desktop Having Feature Of Processor: Intel Core I3 12Th Generation 12100 Or Higher/ Amd Ryzen 3 5000 Series Or Higher; Chipset: Oem Compatible Chipset; Graphics: Integrated Hd Graphics; Memory (Ram): 8 Gb Ddr4 Ram 3200 Mhz Expandable Up To 64 Gb With Min 2 Dimm Slots; Storage: 512Gb Ssd Or Higher; Ports: 6 Usb Ports (Minimum 2 X Usb 3.0 Ports) Or Better, Hdmi Port, Display Port, Rj45, Universal Audio Jack, 4 X Sata Ports, 3 X Pci/ Pcie Slots; Wireless: Wi-Fi, Bluetooth; Audio: High-Definition Audio; Display: 21.5 Led Display With 1920 X 1080 Resolution Or Better, Tco 8.0 Or Higher (Same Make As Pc); Keyboard & Mouse: Oem Usb Keyboard & Oem Optical Scroll Mouse (Same Make As Pc); Form Factor: Small Form Factor With Tool Less Chassis Not More Than 10 Liters; Operating System: Pre-Loaded Windows 11, Certified From Supplied Os (Bid Specific Maf Require On The Name Of Oem For Preloading Windows); Security: Product Supplied Should Be With Tpm 2.0; Other Items: Compatible Headphone With Microphone; , Supply, Installation, Testing And Commissioning Of Digital Application With E-Content Having Features Of Main Interface On Server: Main Page Shall Show Various Types Of Contents Available On The Stand-Alone Server; Offline Connectivity To Client Devices: Should Work On Lan, Create Local Wi-Fi To Access The Content; Devices And Content Support: Should Be Able To Deliver Contents Like Audio, Video, Text, Image To Desktop And Laptop; Min Concurrent Users: 15 In Each Lab; Software Features: Can Easily Be Customized By Changing Department/ School Logos, Header Etc. Supplier/ Selected Bidder Shall Not Use Third Party Branding/ Logo Of Individuals; Other Functionalities: Digital Library Should Be Provided With Preloaded Software And Gor Should Not Have To Buy Licenses For Any Application To Use The Solution In Offline Mode. The Digital Library Application Should Work In Server-Client Mode Offline With No Dependency On Internet And Have Offline Applications For Windows Os; Admin Console: Console To Manage Users & Dashboard. This Dashboard Should Be Able To Reflect All Relevant Reports Related To The , Supply, Installation, Testing And Commissioning Of Multi- Function Printer Having Features Of Functions: Print, Scan, Copy; Technology: Ink-Tank; Printing Method: Color & Mono; Paper Size: A4 Or Higher; Print Speed (Minimum): 20 Ppm (Mono) & 10 Ppm (Color) Or Higher; Print Resolution: 600 X 600 Dpi Or Higher; Auto Duplex: Yes; Memory: 256Mb Or Higher; Connectivity: Usb, Ethernet, Wi-Fi; Duty Cycle (Monthly): 5000 Pages Or Higher; Copy Resolution: 600 X 600 Dpi Or Higher; Scan Type & Capacity: 30 Sheets Capacity Adf (Auto Document Feeder); Scan File Format: Pdf, Jpeg, Tiff, Bmp, Etc.; Scan Resolution: 600 X 600 Dpi Or Higher; Input Paper Tray Capacity: 100 Pages Or Higher; Display: Color Lcd Touch Screen; Yield: Pre Installed Boundary Wall & Color Ink Bottle/ Cartridge With Minimum 5000 Pages As Yield (Same Has To Be Mentioned In Oem Maf); Additional Toner Cartridge/ Bottle: Oem Should Supply 1 Company Packed Additional Ink Bottle/ Cartridge With 5000 Pages Yield Each Along With Printer (Same Has To Be Mentioned In Oem Maf); Compatible Operating Systems: Windows And , Supply, Installation, Testing And Commissioning Of Network Switch Having Features Of Type: Unmanaged Network Switch; Network Ports: 16 X 10/100/1000 Mbps Auto-Sensing Utp Rj- 45 Ports; Switching Capacity: 30 Gbps Or Higher; Data Transfer: The Switch Supports Data Transfer At An Average Of 200Mbps Per Port In Full Duplex Mode; Compliance: Ieee 802.3 10Base- T Ethernet, Ieee 802.3U 100Base-Tx Fast Ethernet, Ieee 802.3Ab 1000Base-T Gigabit Ethernet, Ieee802.3X, Ieee802.3Az Standards; Performance: Mac Address Database: 4K, Buffer Memory: 256K Byte, Supports Mdi/Mdi-X Auto Crossover; Power Source: Oem Power Adapter Operating At 230 Volts; Rack: Wall Mount 2U Rack For Switch With Power Strip And Cable Manager; Authorization: Bid Specific Oem Maf Required , Supply, Installation, Testing And Commissioning Of Ups Having Features Of Capacity: 3Kva/ 2.4Kw; Design: True Online Double Conversion; Nominal Input Voltage: 230V; Frequency: 50Hz; Power Factor: 0.99; Type Of Rectifier: Igbt Based Pwm; Voltage Range: 110Vac To 300Vac; Input Frequency Range: 40-70Hz; Charging Method: Constant Voltage Constant Current (Cvcc); Charging Current Capacity: Settable 1/2/4/6; Type Of Batteries: Smf Vrla, Li-Ion, Tubular; Number Of Batteries: 6; Back-Up: Minimum 4680 Vah; Nominal Output Voltage: 208/220/230/240Vac Settable; Output Frequency Range (Batt. Mode): 50 Hz ± 0.1 Hz; Waveform: Pure Sine Wave; Total Harmonic Distortion: Less Than 3% For Linear Load And Less Than 6% For Rcd Load; Inverter: Igbt Based Pwm With Instantaneous Sine Wave Control; Crest Factor: 3:1; Automatic Bypass: In-Built; Overall Efficiency: 90%; Other Features: Intelligent Fan Speed Control, Auto Restart Function; Noise Level: Less Than 58Db @ 1 Meter; Ip Rating: Ip20; Cooling: Forced Air; Fault Indicated On Digital Display Alarms: Led Indication , Supply, Installation, Testing And Commissioning Of Basic Networking, Earthing And Electrification Work Should Be Done To Setup And Run The Digital Library Including All Networking/ Hardware/ Consumables Items, Properly And Safely. Standard Norms Of Computer Lab Setup To Be Accomplished. It Also Includes Supply And Installation Of Network, Work-Group Creation, Configuration With Testing For Smooth Working With All Clients/ System , Supply, Installation, Testing And Commissioning Of Furniture Items Including Table For Teacher - One Unit: Computer Table For Standard Use To Put Computer System, Speakers, Small Accessories, Size (W X D X H): - 1200Mm X 600Mm X 750Mm; Material: Particle Board 18Mm; Lockable Drawers To Keep Important Accessories; Chair For Teacher - One Unit: Non-Revolving And Non-Tilting Chair With Armrest; Backrest Type: Padded; Shoe/ Studs Material: Pvc; Colour Of Seat & Backrest Cover: Maroon/ Blue/ Black; Seat Size (D X W X H) (± 5 Mm): 450 Mm X 480 Mm X 455 Mm; Backrest (W X H) (± 5 Mm): 450 Mm X 420 Mm; Table For Students - Seven Unit: Student Table With Key Board Drawer And Tabletop With Following Features: - Material: Particle Board; Wire Management For Electric & Network Switch: Below Tabletop By Cable Trays; Foot Edge Of Tabletop: Flat With Pvc Lipping; Plain Edge Banded With: 1Mm Pvc Tape; Construction Of Drawer Unit: Wooden Front With Pvc Lipping; Construction Of Pedestal: Free Standing Low Height With Castor; Work Top , Providing And Fixing Of Required All Type Of Cables Like Hdmi/ Vga/ Display, Usb Or Any Other Cables, Connectors, Switches With Pvc Conduit/Casing, Etc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Andaman And Nicobar Islands View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Andaman And Nicobar Islands View Result →
40.
Housing Urban and Rular Development #10647707 Price Bid
Operation And Maintenance Work Of Water Supply Scheme At Industrial Areasarbuda , Growth Centre Phase-I , Phase-Ii , Ambaji And H/C Ambaji , Aburoad Wss , Regular Operation And Maintenance Of Existing Water Supply System Of Industrial Areas As Under- 1 . Operation Of Booster Pumps To Lift Water From Source To Cwr To Sr ( As Per Requirement And To Maintain Hydraulic Head . 2 . Ensure Uninterrupted Regular Water Supply ( As Per Direction Engineer In-Charge ) To Industrial Units Residential Areas , Daily Or Alternatively As Per Decided Or Direction Issued By Engineer In-Charge . 3 . Regular Supervision Or Maintenance Of Clear Water Reservoir , Service Reservoir , And All Pipe ( Rising Or Distribution ) Network Pump Room , Switch Room , Electrical Motor And Complete System To Ensure Adequate Storage Of Row Water For Proper Supply Of Water . 4 . All Minor Materials Like Nut Bolts , Washers , Gland Packing , Socket , Making Thread Etc . Required For Fitting Of G . I . Pipes To Pumps Have To Be Arranged By The Contractor With Labour Charge For The Same . 5 . Local Transportation Of All Types Of Material Required For Repairing Or Replacement Of Pipe Lines , Cables From Riico Office Store Room Or Engineering Shop Or Electrical Shop For All Lead And Lift . 6 . In Case Of Burning Of Motor ( Mono Block And Submersible Pump And Motor ) , Contractor Will Make Immediate Rewinding Or Maintenance Of Electrical Motor And Rectification Of Electrical Fault On His Own Cost As Well As , At Site Must Have Every Time Available Standby Arrangement Of Electrical Motor Of Suitable Power And Capacity . Agency Has To Resolve All Electrical Problems Related Of Jdvvnl Line Etc . In Any Case Water Supply Must Be Resumed Within 24 Hrs Without Assigning Any Reason . 7 . Regular Maintenance Of Pipelines Of Industrial Area For Rising Main Line , Distribution Line , Sluice Valve Or Nrv Etc . Of Complete Water Supply Scheme By Removing Of Leakage As And When Required Without Jointing Material . 8 . Contractor Has To Add Or Mix The Required Quantity Of Alum Or Bleaching Powder Or Disinfectant Materials . The Supply For This Item Will Be Made By The Corporation , But The Contractor Will Intimate Well In Advance About Stoke Position Of Item . 9 . Contractor Will Also Maintain Residual Chlorine In Consumption No Lapse Due To Bleaching Powder Gone Out Of Stoke Will Be Entertained . 10 . Regular Watch And Ward For 24 Hrs . Of Water Supply Campus Contractor Will Be Complete Responsible For Safety And Security Of These Areas As Well As For The Network And System Of Pipeline . ( Raising Main And Distribution Pipe Line Etc . ) 11 . Contractor Will Be Responsible For Timely Collection And Deposition Of Electrical Bill Of Areas Each Month . 12 . Contractor Will Also Have To Execute Connection Or Disconnection Of Water Connection As Directed By Engineer In Charge . Dead Plugs For Disconnection Will Be Arranged By Contractor . No Extra Payment Will Be Made For This Work . 13 . Contractor Or Agency Will Be Solely Responsible For Any Type Of Mishappening Or Accident During The Awarded Work Of Wss , Riico Will Be Not Responsible Or Involved For Any Matter Either Legal Dispute Or Other Matter . 14 . At The Time Of Completion Of The Work Contractor Will Hand Over The Water System Completely In Proper Order And In Running Condition Along With Details Of Inventory . 15 . Contractor Will Maintain The Daily Log Book For Water Supply In The Prescribed Format As Provided By The Engineer In Charge . At The End Of Month Contractor Will Have To Submit Photocopy Of Log Book Of Concerned Month Duly Signed And Certified By Him Along With Bill , Only After Due Verification Of This Log Book And Recommendation Of Satisfactory Performance Of Agency During The Billing Period , Monthly Payment Will Be Released . 16 . Every Major Problem Or Fault In Operation Of Water Supply Scheme For The Concerned Industrial Area Must Be Intimated In Written To The Concerned Engineer In Charge Along With Expected Time Period Desired By The Agency Or Contractor To Resolve The Problem Or Fault . 17 . Any Type Of Complain Must Be Attainted Or Resolved Within 24 Hours By The Agency Or Contractor And In No Case Water Supply Will Be Closed Or Stopped For More Than 24 Hours . 18 . The Labor Cost Of Lowering Or Unlowering From Tube Well Or Open Well Will Be Bear By Contractor . 19 . Contractor Will Provide All Details Of Deputed Staff With Their Id Proof And Mobile No . 20 . All T And P Will Be Provided By The Contractor Including All Safety Measure . 21 . In Case Fails To Comply The Above Terms And Conditions By The Agency Or Contractor A Daily Penalty Of Rs . 1000 Will Be Imposed Or Recovered From His Bill Without Assigning Any Reason . 22 . The Corporation Reserve Full Rights To Reject The Contract Any Time If Services Not Found Satisfactory Or Without Assigning Any Reason . For Industrial Area Gc-Iind , 1 Tube Well , 3 Open Well , 4 Pump Room , 2 Pump House , 2 Cwr , 2 Sr . , Regular Operation And Maintenance Of Existing Water Supply System Of Industrial Areas As Under- 1 . Operation Of Booster Pumps To Lift Water From Source To Cwr To Sr ( As Per Requirement And To Maintain Hydraulic Head . 2 . Ensure Uninterrupted Regular Water Supply ( As Per Direction Engineer In-Charge ) To Industrial Units Residential Areas , Daily Or Alternatively As Per Decided Or Direction Issued By Engineer In-Charge . 3 . Regular Supervision Or Maintenance Of Clear Water Reservoir , Service Reservoir , And All Pipe ( Rising Or Distribution ) Network Pump Room , Switch Room , Electrical Motor And Complete System To Ensure Adequate Storage Of Row Water For Proper Supply Of Water . 4 . All Minor Materials Like Nut Bolts , Washers , Gland Packing , Socket , Making Thread Etc . Required For Fitting Of G . I . Pipes To Pumps Have To Be Arranged By The Contractor With Labour Charge For The Same . 5 . Local Transportation Of All Types Of Material Required For Repairing Or Replacement Of Pipe Lines , Cables From Riico Office Store Room Or Engineering Shop Or Electrical Shop For All Lead And Lift . 6 . In Case Of Burning Of Motor ( Mono Block And Submersible Pump And Motor ) , Contractor Will Make Immediate Rewinding Or Maintenance Of Electrical Motor And Rectification Of Electrical Fault On His Own Cost As Well As , At Site Must Have Every Time Available Standby Arrangement Of Electrical Motor Of Suitable Power And Capacity . Agency Has To Resolve All Electrical Problems Related Of Jdvvnl Line Etc . In Any Case Water Supply Must Be Resumed Within 24 Hrs Without Assigning Any Reason . 7 . Regular Maintenance Of Pipelines Of Industrial Area For Rising Main Line , Distribution Line , Sluice Valve Or Nrv Etc . Of Complete Water Supply Scheme By Removing Of Leakage As And When Required Without Jointing Material . 8 . Contractor Has To Add Or Mix The Required Quantity Of Alum Or Bleaching Powder Or Disinfectant Materials . The Supply For This Item Will Be Made By The Corporation , But The Contractor Will Intimate Well In Advance About Stoke Position Of Item . 9 . Contractor Will Also Maintain Residual Chlorine In Consumption No Lapse Due To Bleaching Powder Gone Out Of Stoke Will Be Entertained . 10 . Regular Watch And Ward For 24 Hrs . Of Water Supply Campus Contractor Will Be Complete Responsible For Safety And Security Of These Areas As Well As For The Network And System Of Pipeline . ( Raising Main And Distribution Pipe Line Etc . ) 11 . Contractor Will Be Responsible For Timely Collection And Deposition Of Electrical Bill Of Areas Each Month . 12 . Contractor Will Also Have To Execute Connection Or Disconnection Of Water Connection As Directed By Engineer In Charge . Dead Plugs For Disconnection Will Be Arranged By Contractor . No Extra Payment Will Be Made For This Work . 13 . Contractor Or Agency Will Be Solely Responsible For Any Ty
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
41.
Housing Urban and Rular Development #10647702 Price Bid
Operation And Maintenance Of Water Supply Scheme At Industrial Areasarneshwar , Sheoganj And Sheoganj Ext , Dist . Sirohi Wss , Regular Operation And Maintenance Of Existing Water Supply System Of Industrial Areas As Under- 1 . Operation Of Booster Pumps To Lift Water From Source To Cwr To Sr ( As Per Requirement And To Maintain Hydraulic Head . 2 . Ensure Uninterrupted Regular Water Supply ( As Per Direction Engineer In-Charge ) To Industrial Units Residential Areas , Daily Or Alternatively As Per Decided Or Direction Issued By Engineer In-Charge . 3 . Regular Supervision Or Maintenance Of Clear Water Reservoir , Service Reservoir , And All Pipe ( Rising Or Distribution ) Network Pump Room , Switch Room , Electrical Motor And Complete System To Ensure Adequate Storage Of Row Water For Proper Supply Of Water . 4 . All Minor Materials Like Nut Bolts , Washers , Gland Packing , Socket , Making Thread Etc . Required For Fitting Of G . I . Pipes To Pumps Have To Be Arranged By The Contractor With Labour Charge For The Same . 5 . Local Transportation Of All Types Of Material Required For Repairing Or Replacement Of Pipe Lines , Cables From Riico Office Store Room Or Engineering Shop Or Electrical Shop For All Lead And Lift . 6 . In Case Of Burning Of Motor ( Mono Block And Submersible Pump And Motor ) , Contractor Will Make Immediate Rewinding Or Maintenance Of Electrical Motor And Rectification Of Electrical Fault On His Own Cost As Well As , At Site Must Have Every Time Available Standby Arrangement Of Electrical Motor Of Suitable Power And Capacity . Agency Has To Resolve All Electrical Problems Related Of Jdvvnl Line Etc . In Any Case Water Supply Must Be Resumed Within 24 Hrs Without Assigning Any Reason . 7 . Regular Maintenance Of Pipelines Of Industrial Area For Rising Main Line , Distribution Line , Sluice Valve Or Nrv Etc . Of Complete Water Supply Scheme By Removing Of Leakage As And When Required Without Jointing Material . 8 . Contractor Has To Add Or Mix The Required Quantity Of Alum Or Bleaching Powder Or Disinfectant Materials . The Supply For This Item Will Be Made By The Corporation , But The Contractor Will Intimate Well In Advance About Stoke Position Of Item . 9 . Contractor Will Also Maintain Residual Chlorine In Consumption No Lapse Due To Bleaching Powder Gone Out Of Stoke Will Be Entertained . 10 . Regular Watch And Ward For 24 Hrs . Of Water Supply Campus Contractor Will Be Complete Responsible For Safety And Security Of These Areas As Well As For The Network And System Of Pipeline . ( Raising Main And Distribution Pipe Line Etc . ) 11 . Contractor Will Be Responsible For Timely Collection And Deposition Of Electrical Bill Of Areas Each Month . 12 . Contractor Will Also Have To Execute Connection Or Disconnection Of Water Connection As Directed By Engineer In Charge . Dead Plugs For Disconnection Will Be Arranged By Contractor . No Extra Payment Will Be Made For This Work . 13 . Contractor Or Agency Will Be Solely Responsible For Any Type Of Mishappening Or Accident During The Awarded Work Of Wss , Riico Will Be Not Responsible Or Involved For Any Matter Either Legal Dispute Or Other Matter . 14 . At The Time Of Completion Of The Work Contractor Will Hand Over The Water System Completely In Proper Order And In Running Condition Along With Details Of Inventory . 15 . Contractor Will Maintain The Daily Log Book For Water Supply In The Prescribed Format As Provided By The Engineer In Charge . At The End Of Month Contractor Will Have To Submit Photocopy Of Log Book Of Concerned Month Duly Signed And Certified By Him Along With Bill , Only After Due Verification Of This Log Book And Recommendation Of Satisfactory Performance Of Agency During The Billing Period , Monthly Payment Will Be Released . 16 . Every Major Problem Or Fault In Operation Of Water Supply Scheme For The Concerned Industrial Area Must Be Intimated In Written To The Concerned Engineer In Charge Along With Expected Time Period Desired By The Agency Or Contractor To Resolve The Problem Or Fault . 17 . Any Type Of Complain Must Be Attainted Or Resolved Within 24 Hours By The Agency Or Contractor And In No Case Water Supply Will Be Closed Or Stopped For More Than 24 Hours . 18 . The Labor Cost Of Lowering Or Unlowering From Tube Well Or Open Well Will Be Bear By Contractor . 19 . Contractor Will Provide All Details Of Deputed Staff With Their Id Proof And Mobile No . 20 . All T And P Will Be Provided By The Contractor Including All Safety Measure . 21 . In Case Fails To Comply The Above Terms And Conditions By The Agency Or Contractor A Daily Penalty Of Rs . 1000 Will Be Imposed Or Recovered From His Bill Without Assigning Any Reason . 22 . The Corporation Reserve Full Rights To Reject The Contract Any Time If Services Not Found Satisfactory Or Without Assigning Any Reason . For Industrial Area Sarneshwar , 1 Pump House , 1 Cwr , 1 Sr . , Regular Operation And Maintenance Of Existing Water Supply System Of Industrial Areas As Under- 1 . Operation Of Booster Pumps To Lift Water From Source To Cwr To Sr ( As Per Requirement And To Maintain Hydraulic Head . 2 . Ensure Uninterrupted Regular Water Supply ( As Per Direction Engineer In-Charge ) To Industrial Units Residential Areas , Daily Or Alternatively As Per Decided Or Direction Issued By Engineer In-Charge . 3 . Regular Supervision Or Maintenance Of Clear Water Reservoir , Service Reservoir , And All Pipe ( Rising Or Distribution ) Network Pump Room , Switch Room , Electrical Motor And Complete System To Ensure Adequate Storage Of Row Water For Proper Supply Of Water . 4 . All Minor Materials Like Nut Bolts , Washers , Gland Packing , Socket , Making Thread Etc . Required For Fitting Of G . I . Pipes To Pumps Have To Be Arranged By The Contractor With Labour Charge For The Same . 5 . Local Transportation Of All Types Of Material Required For Repairing Or Replacement Of Pipe Lines , Cables From Riico Office Store Room Or Engineering Shop Or Electrical Shop For All Lead And Lift . 6 . In Case Of Burning Of Motor ( Mono Block And Submersible Pump And Motor ) , Contractor Will Make Immediate Rewinding Or Maintenance Of Electrical Motor And Rectification Of Electrical Fault On His Own Cost As Well As , At Site Must Have Every Time Available Standby Arrangement Of Electrical Motor Of Suitable Power And Capacity . Agency Has To Resolve All Electrical Problems Related Of Jdvvnl Line Etc . In Any Case Water Supply Must Be Resumed Within 24 Hrs Without Assigning Any Reason . 7 . Regular Maintenance Of Pipelines Of Industrial Area For Rising Main Line , Distribution Line , Sluice Valve Or Nrv Etc . Of Complete Water Supply Scheme By Removing Of Leakage As And When Required Without Jointing Material . 8 . Contractor Has To Add Or Mix The Required Quantity Of Alum Or Bleaching Powder Or Disinfectant Materials . The Supply For This Item Will Be Made By The Corporation , But The Contractor Will Intimate Well In Advance About Stoke Position Of Item . 9 . Contractor Will Also Maintain Residual Chlorine In Consumption No Lapse Due To Bleaching Powder Gone Out Of Stoke Will Be Entertained . 10 . Regular Watch And Ward For 24 Hrs . Of Water Supply Campus Contractor Will Be Complete Responsible For Safety And Security Of These Areas As Well As For The Network And System Of Pipeline . ( Raising Main And Distribution Pipe Line Etc . ) 11 . Contractor Will Be Responsible For Timely Collection And Deposition Of Electrical Bill Of Areas Each Month . 12 . Contractor Will Also Have To Execute Connection Or Disconnection Of Water Connection As Directed By Engineer In Charge . Dead Plugs For Disconnection Will Be Arranged By Contractor . No Extra Payment Will Be Made For This Work . 13 . Contractor Or Agency Will Be Solely Responsible For Any Type Of Mishappening Or Accident During The Awarded Work Of Wss , Riico Will B
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
49.
Health and Family Welfare #10430067 Price Bid
Tender For Design, Supply, Installation, Testing And Commissioning Of State-Of-The-Art Ip Based Surveillance System For Hbch Sangrur. (Electronic Surveillance System (Cctv)); 1 SITC OF IP Bullet/Dome FIX LENS CAMERA 5MPIP Camera with following featuresVideo Standard NTSC / PAL Scanning System Progressive, Image Sensor -1/2.8” CMOS ,Sensor Size (H x V)- 5.184 mm x 3.888 mm Number Of Pixels(H x V) -2592 x 1944 Minimum Illumination (Color/BW)- 0.007 Lux/F2.0 (Color,30 IRE), 0 Lux/F2.0 (IR ON)S/N Ratio-50 dB, Electronic Shutter Speed-1/8 ~ 1/32,000, IR Distance- up to 40/50+A1 m IR Light Control Smart IR (Auto/Manual)/OFF, IR Light Number- 4 no., Day/Night- Auto (ICR) / Color / BW, Backlight Compensation- WDR,BLC,HLC, White Balance- Auto/Tungsten/ Fluorescent/ Daylight/ Shadow/Manual, Gain Control- 0-100%, Wide Dynamic Range-120 dB, Noise Reduction-2D/3D DNR, Lens-2.8mm, Fixed Iris, F2.0, Angle Of View- H:88°, V:65° , Privacy Masking- Off / On (4 Areas), Defog- Supported, Local Storage- Micro SD (up to 256 GB), Alarm Inputs/Outputs-1 In / 1 Out, Video Compression- H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution-1st: 2592 x 1944 / 2592 x 1520 /1920 x 1080 / 1280 x 720 2nd: 704 x 576(PAL) / 704 x 480(NTSC) / 640 x 480 / 352 x 288(PAL) / 352 x 240(NTSC) 3rd: 1920 x 1080 (MAX 12 fps) / 640 x 480 / 352 x 288(PAL) / 352 x 240(NTSC) / 320 x 240, Number of Video Streams-3 (2 for encryption), Frame Rate- MAX 30 fps, Bit Rate-100K~12 Mbps, Audio Compression- G.711A/G.711U, Audio Stream-2-Way, Full duplex, Audio Interface- Line In/Out, Ethernet-10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers- Chrome/Edge, Supported OS- Microsoft Windows 10, Protocols- IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability- ONVIF Profile G/S/T, Maximum Users Access-10 Users, Security- User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH/ Telnet closed, PCI-DSS compliance, Built-in Video Analytics- People Counter, Multi Loitering, Intru- sion, Tampering, Smart Motion Detection (SMD), Motion Detection, Event Type- Video motion detection, Alarm input, Recording notification, Tampering, Event Linkage- Event notification using digital output, Email and MicroSD card, Region Of Interest-8, Power Supply- DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption- MAX 6W, Body Material- Die-cast aluminium housing, Operating Temperature- -40°C ~ 60°C (-40°F ~ 140°F), Relative Humidity- Less than 90 %, non-condensing, Ingress Protection- IP67, Bullet Casing-IK10, Emissions- FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity- CE(EN 50130-4), Complies with RCM and UKCA, Safety- UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs- CE(EN 63000),UAE(Cabinet Decree No.10 of 2017) complete in all respect as desired by the engineer in charge at site. 2 Supply OF IP Bullet Vari-focal LENS CAMERA 5MPIP Camera with following featuresVideo Standard NTSC / PAL Scanning System Progressive, Image Sensor -1/2.8” CMOS ,Sensor Size (H x V)- 5.184 mm x 3.888 mm Number Of Pixels(H x V) -2592 x 1944 Minimum Illumination (Color/BW)- 0.005 Lux/F1.6 (Color,30 IRE), 0 Lux/F1.6 (IR ON)S/N Ratio-50 dB, Electronic Shutter Speed-1/8 ~ 1/32,000, IR Distance- up to 60 m IR Light Control Smart IR (Auto/Manual)/OFF, IR Light Number- 4 no., Day/Night- Auto (ICR) / Color / BW, Backlight Compensation- WDR,BLC,HLC, White Balance- Auto/Tungsten/ Fluorescent/ Daylight/ Shadow/Manual, Gain Control- 0-100%, Wide Dynamic Range-120 dB, Noise Reduction-2D/3D DNR, Lens-2.7-13.5mm, DC Iris, F1.6-3.3,MFZ Angle Of View- H:88°-26°, V:65°-20° , Privacy Masking- Off / On (4 Areas), Defog- Supported, Local Storage- Micro SD (up to 256 GB), Alarm Inputs/Outputs-1 In / 1 Out, Video Compression- H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution-1st: 2592 x 1944 / 2592 x 1520 /1920 x 1080 / 1280 x 720 2nd: 704 x 576(PAL) / 704 x 480(NTSC) / 640 x 480 / 352 x 288(PAL) / 352 x 240(NTSC) 3rd: 1920 x 1080 (MAX 12 fps) / 640 x 480 / 352 x 288(PAL) / 352 x 240(NTSC) / 320 x 240, Number of Video Streams-3 (2 for encryption), Frame Rate- MAX 30 fps, Bit Rate- HC35WB5R3: 100K~12 Mbps, Audio Compression- G.711A/G.711U, Audio Stream-2-Way, Full duplex, Audio Interface- Line In/Out, Ethernet-10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers- Chrome/Edge, Supported OS- Microsoft Windows 10, Protocols- IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability- ONVIF Profile G/S/T, Maximum Users Access-10 Users, Security- User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH/ Telnet closed, PCI-DSS compliance, , Built-in Video Analytics- People Counter, Multi Loitering, Intrusion, Tampering, Smart Motion Detection (SMD), Motion Detection, Event Type- Video motion detection, Alarm input, Recording notification, Tampering, Event Linkage- Event notification using digital output, Email and MicroSD card, Region Of Interest-8, Power Supply- DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption- MAX 6W, Body Material- Die-cast aluminium housing, Operating Temperature- -40°C ~ 60°C (-40°F ~ 140°F), Relative Humidity- Less than 90 %, non-condensing, Ingress Protection- IP67, Bullet Casing-IK10, Emissions- FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity- CE(EN 50130-4), Complies with RCM and UKCA, Safety- UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs- CE(EN 63000),UAE(Cabinet Decree No.10 of 2017) complete in all respect as desired by the engineer in charge at site 3 SITCOF 64 Channel IP INPUTNVR 4Kwith 4 HDD Slots having following featuressupport 16 channels simultaneously with synchronized real-time playback Up to 8 MP (4K) resolution live view and playback. Supports H.265 HEVC, H.264, Smart Codec. Notify on triggering built-in video analytic alarms from 35S cameras: Crowd, Multi Loitering, Intrusion, Tampering, Motion and Smart Motion Detection (SMD). Two-way audio/push notification. Supports up to 16 alarm input channels and 6 alarm relay output channels. (8 SATA).Maximum incoming bandwidth is 400 Mbps,and Maximum outgoing bandwidth is 400 Mbps.* Supports people counter feature to accurately automate the gathering of data relating to people entering and exiting a certain area. Global P2P/TUTK service with reliable connection and mobile apps for both Apple® and Android™ devices for anytime, anywhere access. P2P integration to manage remote configuration and firmware updating, Internal storage supports 4 HDDs expandable up to 40 TB (4 bays) of internal storage. Store video clips and snapshots to external storage, such as USB device on local side or PC client on web side. Supports RAID*** 1/5/6 storage options, For use as part of video systems which comply with NDAA Section 889, The TPM (Trusted Platform Module) provides end-to-end stream and command encryption through integrated cryptographic keys, Dual network ports, making it easy to connect local IPCs and remote control, Main Processor- ARM Processor, Security- Encrypted streaming and control, Audio Input/ Output-3.5 mm Line in x1 3.5 mm Line out x1, Two-way Communication-Supported, Interface- HDMI 1 (4K Max), HDMI 2 (1080P), VGA x1 (1080P), PTZ Operation- Direction control, Home, Iris, Preset, Patrol (group), Focus +/- Zoom+/-,Compression- H.265/H.264, Recording Throughput- upto 400mbps, RAID- RAID* 1/5/6, Sync Playback- 16 channels, Ethernet-10/100/1000 Mbps Ethernet (RJ-45) x 2,Supported Protocols- IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, SMTP, FTP, DHCP, NTP (Secure), DNS, DDNS, IP Filter, P2P, SNMP, Maximum Number Of Users-16, USB Ports- 3 No. Power Supply-100-240V AC, 50/60 Hz, Power Consumption-200 Watt, Operating Temperature--10°C ~ 55°C (14°F ~ 131°F), Emissions- FCC Part 15, CE (EN 55032, EN 61000-3-2, EN 61000-3-3, EN 61000-6-4),ICES-003, Comply with UKCA and RCM, Immunity- CE (EN 50130-4, EN 55035) Comply with UKCA and RCM, Safety- UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Comply with UKCA and RCM, RoHS- CE(EN 63000), UAE (Cabinet Decree No.10 of 2017) complete in all respect as desired by the engineer in charge at site. 4 SITCof 8000GB Audio VideoSurvillance HDD for NVRrecording and playback complete in all respect as desired by the engineer in charge at site. 5 SITC of 8 Port POE 120+ Watts Hardware managed 10/100/1000 MbpsData switch IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet with 02 No. 10/100/1000 Mbps copper Port. 6 SITC of 8 Port POE 65+ Watts Hardware managed 10/100/1000 MbpsData switch IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet with 1 No.10/100/1000 Mbps SFP Port. 7 SITC of 16 Port POE 150+ Watts Hardware managed 10/100/1000 MbpsData switch IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet with 2 No.10/100/1000 Mbps SFP Port. 8 SITC of 24 Port POE 193+ Watts Hardware managed 10/100/1000 MbpsData switch IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet with 4 No.10/100/1000 Mbps SFP Port. 9 SITC of 24SFP Port 10/100/1000 Mbps Managed L2 Data switch and 2 No. Copper Port 10/100/1000 Mbps SFP Portshaving IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet, Switching capacity 40 Gbps, HOL blocking prevention, 802.1p priority based, hardware queues, priority queuing and Weighted Round-Robin (WRR) Jumbo frame,VLAN support, Spanning Tree Protocol (STP), advanced threat protection, Standard 802.1d Spanning Tree support Fast convergence using 802.1w (Rapid Spanning Tree [RSTP]), enabled by default Multiple Spanning Tree instances using 802.1s (MSTP); 8 instances are supported, Per-VLAN Spanning Tree Plus (PVST+) and Rapid PVST+ (RPVST+); 126 instances are supportedIPv6 first-hop security, Support for up to 4,094 VLANs simultaneously Port-based and 802.1Q tag-based VLANs; MAC-based VLAN; protocol-based VLAN; IP subnet-based VLAN, Management VLAN, Wire speed routing of IPv4 packets Up to 990 static routes and up to 128 IP interfaces ,Configuration of Layer 3 interface on physical port, Link Aggregation (LAG), VLAN interface, or loopback interface ,Switch functions as an IPv4 DHCP server serving IP addresses for multiple DHCP pools/scopes, Support for DHCP options ,USB Type-A slot on the front panel of the switch for easy file and image management, Reset button, UL (UL 62368), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A, Operating temperature 23° to 122°F (-5° to 50°C)quality of service (QoS), dynamic routing Smart Managed Data switchhaving IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet, Switching capacity 100 Gbps,Flash 256MB,DRAM 512, Processor 800Mhz,HOL blocking prevention, 802.1p priority based, hardware queues, priority queuing and Weighted Round-Robin (WRR) Jumbo frame. Console port . 10 SITC of 55” COMMERCIAL LED PANNEL with 2 HDMI Port, VGA Input, in built speaker, min. 50000 hours panel life, computer input, TV INPUT , 4K UHD ,Network Port,complete in all respect as desired by the engineer in charge at site. 11 SITCof 2 meter 4K long superior qualityHDMI Cable complete in all respect as desired by the engineer in charge at site. Make 12 SITCof RJ-45 Male connector complete in all respect as desired by the engineer in charge at site. 13 SITC of 24U Floor mount 19’’ Rack with glass door,lock & key facility 400mmdepth with CPD & Fan. 14 SITC of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400mmdepth with CPD & Fan. 15 SITC of 9U Outdoor Wall mount 19’’ Rack with glass door,lock & key facility 400mmdepth with CPD & Fan. 16 SITC of 3KVA Online UPS with required no. SMF batteries, connecting cables and Rack having Minimum 15 Minutes backup time. 17 SITC of 1KVA LIT UPS having in-built SMF batteries having 15 Minutes backup time. 18 SITCofCAT6 UTP Networking Cable of 10/100/1000Mbps DCC in existing PVC conduit complete in all respect as desired by the engineer in charge at site. 19 SITCofCAT6 UTP Outdoor armound Networking Cable of 10/100/1000Mbps DCC in existing PVC conduit complete in all respect as desired by the engineer in charge at site. 20 SITCof 6 Core Optical Fiber Cable of 10/100/1000/10000 Mbps DCC in existing PVC conduit complete in all respect as desired by the engineer in charge at site. 21 SITC of Camera mounting Pole fabricated out of G.I.Pipe17 Feet Height above ground and 3 feet below earth level inconcrete muff, Diameter 4 inches, Muff, Provision for Rack Mounting, with installation, grouting ,with earthing, Camera Mounting Disk for 1 to 4 cameras on top complete in all respect. with installation complete in all respect. 22 SITC of fiber termination box with 01 No. Fiber adaptor,1 No. SFP Module TX-RX Type, Single Mode,1 No. LC-LC type Fiber Patch cord,06 No. LC Type Fiber Pig Tail including Fiber Splicing. 23 SITC of fiber termination LIU with 01 No. Fiber Adaptor1 No. SFP Module TX-RX Type, Single Mode,1 No. LC-LC type Fiber Patch cord,06 No. LC Type Fiber Pig Tail including Fiber Splicing. 24 SITC of computer of custom Builti5 11th Gen. or above Intel Core Processor/16GB DDR4 RAM/512GB SSD/4GB Dedicated Graphic Card/OEM Windows10 /500 Watts SMPS Power SITC with 32 inches HDMI Monitor, Keyboard and Mouse, 5 Mtr HDMI Cable for maintenance of IP Cameras complete in all respectas per site Requirement. 25 SITC 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination, ID Plate PC transparent color with paper, Panel: SPCC,1.5mm thickness with black color painted, RJ45 Jack- Housing: P B T + g la ss fiber, UL-94V-0 Contact Brackets: PBT + glass fiber, UL-94V-0, RJ45 Jack Contact- Material: Phosphor bronze with nickel plated Finish: 50 micro-inches Gold plated on plug contact area, IDC Housing: PC, UL 94V-0 Terminal: phosphor bronze with tin plated, e ANSI/TIA/EIA 568C.2 & ISO/IEC 11801 standard. 26 SITC 12 Port Fully loaded Patch Panel, Rack Mountable for cable termination, ID Plate PC transparent color with paper, Panel: SPCC,1.5mm thickness with black color painted, RJ45 Jack- Housing: P B T + g la ss fiber, UL-94V-0 Contact Brackets: PBT + glass fiber, UL-94V-0, RJ45 Jack Contact- Material: Phosphor bronze with nickel plated Finish: 50 micro-inches Gold plated on plug contact area, IDC Housing: PC, UL 94V-0 Terminal: phosphor bronze with tin plated, e ANSI/TIA/EIA 568C.2 & ISO/IEC 11801 standard. 27 SITC of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps Conductor: 24 AWG, Multi-strands Conductor Metal: Bare Copper Insulation Material: HD-PE Material: FR-PVC s TIA/EIA 568C.2 standard ISO/IEC 11801 Class EA. Gold Plated: 50U° Contact Blade: Copper Alloy Dielectric withstanding voltage: 1000V DC/min, 500M Ù, 1000V DC/min UL Applications: PC UL94-V-0 28 SITC of 25mm PVC Pipe Heavy with allied accessories bend junction etc complete in all respect 29 SITC of Information outlet CAT6 with 3 x3 inches polycarbonate sheet with Back Box. 30 SITC of camera mounting Box 4 x4 inches PVC Heavy 31 SITC GI Wire for Cable installation In KG 32 Supply, Laying and fixing of GI Raceway 100 X 50 MM with cover , anchoring with 8mm thread Rod and bullet fastner 33 CAMC FOR 2 YEARS AFTER THE MINIMUM DLP PERIOD OF 2 YEARSFROM THE DATE OF HANDOVER OF the Project
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
TenderDetail
Loading tenders