View Bid Results For Load Flow Analysis Tenders

We found 134 Bid Results related to load flow analysis tenders. You can find Contractor details who won load flow analysis tenders along with contract details in Bid awards announcements section.

Filters
Stage
100
24
10
Tender Publishing Platform
10
124
State / UT
22
23
22
18
11
7
5
5
5
5
4
4
4
4
3
3
3
2
2
1
1
1
1
Contract Value
38
11
51
33
Publish Date
0
0
0
0
0
Sector
15
34
20
15
15
14
9
8
6
4
2
2
2
1
1
1
Ownership
4
81
24
18
11
Within keyword
Active filters:
Showing 1–3 of 134 tenders matching your filters
1.
Educational and Research Institute #11291088 AOC
Tender for Purchase Of Integrated Electric Motor Drive With Realtime Data Acquisition , Specifications , • Should Have An Inbuilt Controller With Ram And Flash Memory • Interfaces And Features O Voltage Sensor:  Rating: +/- 1000V  Bandwidth: Dc To 250 Khz  Adc: Delta Sigma A/D  Resolution: 16 Bits  Sample Rate: Up To 1 Msps/Ch O Current Sensor  Rating: +/- 80A Peak To Peak, 25A Rms  Bandwidth: Dc To 250 Khz  Adc: Delta Sigma A/D  Resolution: 16 Bits  Sample Rate: Up To 1 Msps/Ch O Should Provide Pwms Of 5V To The Driver Along With Fault Feedback, Reset Function And Dynamic Short Circuit Protection. O Should Have Two Encoder Channel Interface For Speed Measurement And Position Estimation Which Can Be Connected To Motors Encoder And Position Sensors. O Should Have An Inbuilt Lc Filter For The Buck And Boost Operation. O Should Have An Inbuilt Inductor Rating Of 5Mh, 15A. O Should Have Inbuilt Power Capacitors Of Rating Not Less Than 3300Μf With Voltage Rating Not Less Than 400V O Should Have Appropriate Dc Link Capacitors With Dc Voltage Rating Of 350V/600V. O The System Should Be Provided With Single-Phase/Three-Phase Mcb With 16A Protection. O Should Have An Inbuilt Three Phase Uncontrolled Rectifier With Three-Phase Input Voltage Of 415V Ac L-L, And Output Of 600V Dc Should Be Included. O Should Have An Inbuilt Igbt-Based Converter Of 600V Dc Not Less Than 5Kva Capacity For Relevant Drive Operations. • Pwm Generator O The Pwm Generator Should Be Of User Configurable Type. O Carrier Wave Type: Positive Ramp Positive, Negative Ramp, Triangular Wave, Inverse Triangular Wave. O High And Low Threshold Values Should Be Of User Configurable. O Switching Frequency Capability Up To 1Mhz. O Should Have Pwm Short Circuit Protection With Master Trip And Error Flag Indication. • Protections/ Safety O User Configurable Threshold Limits For Over Voltage Protection (Definitive & Instantaneous) O User Configurable Threshold Limits For Under Voltage Protection (Definitive & Instantaneous) O User Configurable Threshold Limits For Over Current Protection (Definitive & Instantaneous) O User Configurable Threshold Limits For Under Current (Definitive & Instantaneous) O User Configurable Threshold Limits For Over Threshold (Definitive & Instantaneous) O Under Threshold And Sensor Error O Should Have Dedicated Indicators • Inbuilt Pc With Touch Screen For The Measurement And Analysis With Following Software Features: O I5 Processor With 8Gb Ram, 128Gb Ssd Sdd, Wifi, Bluetooth, Usb Port, Minimum 15 Inches Industrial Touch Panel Pc And Bluetooth Mouse. • Input / Output Registers O Adequate Number Of Input And Output Registers For Run Time Control Commands And Online Tuning Of User Selected Control Parameters. • Real-Time Storage O Storage Of Real-Time Data For Post Analysis And Data Export Provision To Picture And Data File Format. • Time Plot O Plot Signals Vs Time O Line Plot, Dot Plot O Save Data And Save Figure Options O Offline Analysis (Pause & Analyze) O Time Cursor, Amplitude Cursor O Should Have Up To 16 Number Of Plots O Should Have Up To 8 Signals Per Plot O Individual Y-Axis Per Signal Or Common Y-Axis O Own Window Or Dashboard Widget Option • General Plot O X Vs Y Plot O Line Plot, Dot Plot O Save Data And Save Figure Options O Should Have Up To 16 Number Of Plots O Should Have Up To 8 Signals Per Plot O Individual Y-Axis Per Signal Or Common Y-Axis O Should Have Own Window Or Dashboard Widget Option O Should Highlight The Current Value • Fft Panel To Display Or Measure O Fundamental Frequency O Total Harmonic Distortion (Thd) O Distortion Factor O Harmonic Components Of Signal (Rms, Peak) O Up To 50Th Order Harmonics Report • Power Panel Should Have O A Time-Based Power Measurement. O Measurement Configuration: Single-Phase 2-Wire, Two-Phase 3-Wire, Three-Phase 3-Wire, Three-Phase 4-Wire And Four-Phase. O Output Signals: Active Power (P), Reactive Power (Q), Apparent Power (S), Power Factor (Pf) And Instantaneous Power (Pinst). O Output Table: Rms, Avg, Max And Min Values For Inputs Signals O The Capability To View, Plot And Save Output Signals. O The Provision For Power Vector Diagram. • Should Have Not Less Than 8 User Configurable Dashboards. • Should Provide 64 Probe Panels. • Should Provide Dashboard Arrangement For Experiment Setups. • Should Support Popular Software Package For Captured Data Analysis. • Should Provide View And Analysis Feature Of Instantaneous Pwm Signals, Speed, Position Signals, Input Voltages, Output Voltages, Input Currents And Output Currents Over A Time Plot. • Should Have Provision For Rms, Average, Maximum And Minimum Value Measurement Of Input Voltage, Output Voltages, Input Current And Output Current. • Should Have Provision For Measurement And Analysis Of Instantaneous Input Active Power, Output Active Power, Reactive Power, Instantaneous Output Reactive Power, Instantaneous Input Apparent Power, Instantaneous Output Apparent Power, Input Power Factor And Output Power Factor. • Should Have Provision For Buzzer And Fault Indication On The Display. • Should Have Model Development Flow Through Popular Software Package: Modelling To Binary Generation Within The Software Environment, Generated Binary Must Run On A Higher End Processor Natively With Io Interfacing And Protection Function. • Ability To Generate Pwm Signals Independent Of Control Function Sample Time • Controller Device Library Should Be Provided For A Popular Software Package Environment Should Support The Following List Of Experiments And Must Supply The Source Codes In A Popular Software Package 1. Open Loop Speed Control Of Three Phase Induction Motor Of 1Kw With Mechanical Loading And 1024 Ppr Encoder That Can Be Interfaced With The Above Controller. 2. Clore Loop Speed Control Of Three Phase Induction Motor Of 1Kw With Mechanical Loading And 1024 Ppr Encoder That Can Be Interfaced With The Above Controller. 3. Open Loop Speed Control Of Bldc Motor Of 1Kw With Mechanical Loading And 1024 Ppr Encoder That Can Be Interfaced With The Above Controller. 4. Close Loop Speed Control Of Bldc Motor Of 1Kw With Mechanical Loading And 1024 Ppr Encoder That Can Be Interfaced With The Above Controller. 5. Open Loop Speed Control Of Pmsm Of 1Kw With Mechanical Loading And 1024 Ppr Encoder That Can Be Interfaced With The Above Controller. 6. Close Loop Speed Control Of Pmsm Of 1Kw With Mechanical Loading And 1024 Ppr Encoder That Can Be Interfaced With The Above Controller. 7. Study Of Open Loop And Closed Loop Control Of Single-Phase Inverter Operation With R-Load. 8. Study Of Open Loop And Closed Loop Control Of Three Phase Inverter Operation With R-Load. 9. Study Of Open Loop And Closed Loop Control Of Dc-Dc Buck Converter Operation With R-Load. 10. Study Of Open Loop And Closed Loop Control Of Dc-Dc Boost Converter Operation With R-Load.
Contract Date: Jun 25, 2026 Contract Value : 9.96 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
2.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
3.
Educational and Research Institute #10967168 AOC
Equipment For Civil Lab Equipment For Civil Lab, Basic Civil Lab, Transport And Highway Lab, Advance Structural Lab , Equipment For Basic Civil Engineering Laboratory (Sheet 1) , Equipment For Advanced Structural Testing Laboratory(Sheet 2) , Equipment For Transportation & Highway Laboratory (Sheet 3) , Service(Sheet 4)-1 1 Concrete Mixer, Pan Type 2 Mould, Cast Iron, for 150mm Cube with ISI marked and NABL calibration Certificate 3 Beam Mould, 100mm x 100mm x 500mm 4 Beam Mould, 150mm x 150mm x 700mm 5 Cylindrical Mould, Cast Iron, Split Lengthwise 150 mm diameter x 300mm high 6 Mould, Steel, for 70.6mm cube with ISI Mark and NABL calibration Certificate 7 Tamping Rod 8 Vibrating Table 9 Slump Test Apparatus 10 Consistometer (Vee Bee Consistometer) 11 Flow Table, Motorized 12 Compaction Factor Apparatus 13 Concrete Penetrometer, Spring Type 14 Air Entrainment Meter Capacity 0.005m3 (5 liters) suitable for aggregate size up to 38mm 15 Curing Tank for 6/24moulds of 150mm/70.6mm size with NABL Calibration Certificates 16 Accelerated Curing Tank for 6 moulds of 150mm size with NABL Calibration Certificates 17 Capping Set, Vertical, for capping 150mm dia cylinders and cores 18 Concrete Permeability Apparatus 19 Compressor for Permeability Apparatus 20 Air Permeability Apparatus (Blaine type) 21 Vicat Apparatus 22 Le-Chatelier Mould 23 Le-Chatelier Water Bath with Controller 24 Le-Chatelier Flask 25 Shrinkage Bar Mould with NABL Calibration Certificate 26 Cement Autoclave 27 Length Comparator, Digital 28 Flow Table, Electric Operated 29 Automatic/Manual Digi Mortar Mixer Capacity 4.75litre 30 Vibration Machine, with built-in Digital Timer, NABL Calibrated 31 Gauging Trowel 32 Gauging Trowel 33 Sieves Set (Course) 34 Sieves Set (Fine) 35 Concrete test Hammer 36 Automatic Compression Testing Machine 37 Flexure Test Attachment 38 RCPT (4 CELL MODEL) 39 Drying Shrinkage 40 Carbonation Test Chamber 41 1000kN Beam Testing Set Up 42 Pycnometer 43 Pull off tester 44 Hot Air Oven 45 Sieve shaker (Motorized) 46 Sieve shaker (Motorized) 47 Electronic Weighing Balance with Legal Metrology Test Certificate 48 Electronic Weighing Balance with Legal Metrology Test Certificate. 49 Electronic Weighing Balance with Legal Metrology Test Certificate. 50 Electronic Weighing Balance with Legal Metrology Test Certificate. 51 Electronic Weighing Balance with Legal Metrology Test Certificate. 52 Impact of Jet on Vanes Apparatus 53 Orifice Meter Apparatus 54 Flow Over Notch Apparatus 55 Friction in Pipelines Apparatus 56 Venturimeter Apparatus 57 Orifice & Mouthpiece Apparatus Bernoullis Theorem Apparatus 59 Reynolds Apparatus60 Metacentric Height Apparatus 61 Study of Pipe Fittings, Sudden Enlargement & Contraction Apparatus 62 Force Vortex Apparatus 63 Pelton Wheel Turbine Test Rig 64 Francis Turbine Test Rig 65 Reciprocating Pump Test Rig 66 Standard Penetration Test (SPT) 67 `A Drill Rod, 1m long complete with adaptor 68 Dynamic Cone Penetration Test Apparatus (DCPT) 69 `A Drill Rod, 1m long complete with adaptor 70 Hand Operated Extractor 38mm mm dia specimen 71 Sampleject-5000, Hydraulic sample extruder, Electronic cum hand operated 72 Speedy Moisture Meter, Range 0-25% (Gauge Div.:0.5%) with digital weighing balance 73 Infra-Red Moisture Meter 74 Liquid Limit Device, motorised, with Casagrande grooving tools and gauge block 75 Liquid Limit Device, Hand Operated, with Casagrande grooving tools and gauge block. 76 Plastic Limit set comprising of glass plate, Brass rod, Spatula, Moisture Tin & Porcelain Dish. 77 Shrinkage Limit Set 78 Universal Penetrometer 79 Penetration Test Cone 80 Penetration Test Cup, 55 mm dia x 50 mm deep 81 Pycnometer 82 Andreasen Pipette Stand 83 High Speed Stirrer New Model 84 Hydrometer, Range: 0.995 to 1 Measuring specific gravity of liquid against buoyancy. Used for particle size analysis of fine grain soil less than 75-micron size 85 Plummet Balance 86 Unconfined Compression Tester for load measurement 87 Digital Direct Shear Test Apparatus, 2kN 88 Compaction Test Apparatus, Manual -Light Compaction made of Mild Steel 89 Compaction Test Apparatus, Manual-Heavy Compaction made of Mild Steel 90 Universal Automatic Compactor with Mild Steel compaction mould 91 Relative Density Apparatus 92 Soil Permeability Apparatus 93 Overhead Tank, made of steel, approx., 37.5cm dia x 1m high 94 Grooved M.S. Plate, 30cm x 30cm square x 25mm thicks + Plate bearing Apparatus with Load Truss of 500kN 95 (Plate Bearing Apparatus) 96 Core Cutter 97 Triaxial Shear Test Apparatus 98 Sand Replacement Method Apparatus 99 Van Shear apparatus 100 Electronic Three Gang Bench Type Consolidometer Front Loading 101 Hot Air Oven 102 Sieve shaker (Motorized) 103 Field CBR Test Apparatus with Proving Ring and Dial Gauge 104 BOD Incubator 105 Turbidity Meter 106 pH Meter 107 Conductivity meter 108 Portable UV Visible Spectrophotometer 109 Dissolved Oxygen meter 110 Portable COD meter 111 TSS analyser 112 TDS Analyzers 113 Particulate Matter Sampler 114 Hot Air Oven 115 Muffle Furnace 116 Digital Colony Counter 117 Water bath 118 Open Reflux COD Digester 119 Electronic Weighing Balance 120 Electronic Weighing Balance 121 Infrared thermometer 122 Microscope 123 Magnetic Stirrer with hot plate 124 Jar Test Apparatus Flocculator 125 Test tube 126 BOD Bottle 127 Porcelain dish 128 Measuring cylinder 129 Filter Paper 130 Burette 131 Burette stand with rod, clamp & boss head 132 Needle Vibrator 133 Vibratory hammer 134 Concrete specimen cutter 135 Curing Tank 136 Accelerated Curing Tank 137 Compressor with Nozzle 138 Deep Refrigerator 139 Refrigerator 1 Thickness Gauge 2 Length Gauge 3 Aggregate Impact Tester 4 Crushing Value Apparatus 5 Los Angeles Abrasion testing machine with counter 6 Density Basket 7 Buoyancy Balance 8 Universal Penetrometer 9 Penetration Cone 10 Bitumen Penetration Kit 11 Ring and Ball Apparatus 12 Thermometer IP 60C 13 Thermometer IP 61C 14 Thermometer IP 8C, Range 0°C to 45°C 15 Thermometer IP 9C, Range 40°C to 85°C 16 Thermometer IP 10C, Range 76°C to 122°C 17 Cannon Manning cum Cannon Fenske Viscometer bath with Vacuum Pump 18 Cannon Manning Vacuum Viscometer Tube, Size 6 19 Cannon Manning Vacuum Viscometer Tube, Size 7 20 Cannon Manning Vacuum Viscometer Tube, Size 12 21 Cannon Manning Vacuum Viscometer Tube, Size 13 22 Thin Film Oven/Loss on Heating Oven 23 Rolling Thin Film Oven 24 Flash Point (Closed) Pensky-Martens Apparatus 25 Thermometer IP 15C Range 5°C to +110°C 26 Thermometer IP 16C Range 90°C to +370°C 27 Flash Point (Open) and Fire Point, PenskyMartens Apparatus 28 Thermometer IP 15C Range 5°C to +110°C 29 Thermometer IP 16C Range 90°C to +370°C 30 Specific Gravity Bottle 31 Ductility Testing Machine with Digital Temperature Indicator 32 Centrifuge Extractor with NABL Calibration Certificate. 33 Marshall Apparatus, 50kN Single Speed 4 Diameter Sample 34 Pavement Core Drilling Machine 35 Diamond Core Bit 36 Asphalt Mixer, 5 L Capacity 37 Skid Resistance Tester 38 Asphalt Mixer Theoretical Density Meter 39 Modified Roughness Indicating Machine (MERLIN) 40 Bump Integrator with pre-set facility and CRRI calibration certificate 41 Pavement Dynamic Cone Penetrometer 42 Film Stripping Device 43 Saybolt Viscometer 44 Mastic Asphalt Tester 45 Serological Water Bath, Double Walled, with Digital Controller Cum Indicator and Stirring Arrangement 46 Brookfiled Viscometer 47 Thin Film Oven 48 Ignition Oven Asphalt Content Tester with IRC Accreditation. 49 Marshal Automatic Compactor 50 Roughometer (wireless) 51 Radar Gun 52 Helium Pycnometer 53 Laboratory Hot Plate 54 Sieve shaker (Motorized) 55 Sieve shaker (Motorized) 1 SCHMIDT Live N 2 Rebound Hammer Sensor Kit (For Rock) Ultrasonic Pulse Velocity 4 Profometer Rebar Detection & Cover Meter with 5 yrs. software subscription 5 Diamond Core Drilling Machine for Concrete 7 Structure Scan Mini LXT for Concrete Scanning 8 Pile Integrity Test 9 PIT-W Professional Software 10 Impact Echo 11 Light Weight Deflect meter 12 Falling Weight Deflectometer 13 Non-nuclear density gauge (for Soil) 14 Non-Nuclear Asphalt Density Gauge 15 Resistivity Meter (1-D) 16 Electrical Resistivity Imaging system & IP-System 17 Single channel & Multichannel Seismograph 18 Ground penetrating Radar (GPR) 19 Microtremor (Passive Seismic monitoring 20 Pneumatic Adhesion Tensile Strength Testing Instrument (PATTI 21 Electronic Weighing Balance with Legal Metrology Test Certificate. 22 Electronic Weighing Balance with Legal Metrology Test Certificate.
Contract Date: May 05, 2026 Contract Value : 7.71 Crore
Government Departments No of Bidders 1
5.
Health and Family Welfare #10894980 AOC
Tender For Medicine/ Consumble/Minor Equipment/Lab Reagents/Dental Items/Surgical & Other Instrument , 2 Fdc (Ped) (Rifampicin-75Mg+Isoniazid-50Mg) , 3 Fdc (Adult) (Rifampicin-150Mg+Isoniazid-75Mg+Pyrizinamide-400Mg) , 3 Fdc (Ped) (Rifampicin-75Mg+Isoniazid-50Mg+Pyridoxine-150Mg) , 3% Ns 100Ml , 3% Ns Respule , 3-0 Mesh For Lap Inguinal Hernia A) Right Side B) Left Side , 4 Fdc (Adult) (Rifampicin-150Mg+Isoniazid-75Mg+Ethambutol-275Mg+Pyrizinamide-400Mg) , 5-Fluorouracil Injection 500Mg, 50Mg/Ml Ampules , 7% Ns Respule , Abdominal Drain 28 No , Abdominal Drain 30 No , Abdominal Drain 32 No , Absorbable Gelatin Sponge, Single Unit, Size - 80*50*10Mm , Aceclofenac Tablet 100 Mg , Acetazolamide Tablet 250 Mg , Acetylsalicylic Acid 75 Mg+Clopidogrel 75 Mg Tablet , Acetylsalicylic Acid Tablet 150 Mg , Acetylsalicylic Acid Tablet 75 Mg , Actinomycin Injection 0.5 Mg , Acyclovir Eye Ointment 3% , 4.5 Gm Tube , Acyclovir Tablet 200 Mg , Acyclovir Tablet 400 Mg , Acyclovir Tablet 800 Mg , Adenosine Injection 3 Mg/ Ml, 1 Ml Ampoule , Adrenaline Injection 1 Mg/Ml, 1:1000, 1 Ml Annual Periodical Maintenance , Adrenaline Intracameral Injection For Eye , Agfa Cr Film (Dt2B)(1X100) 10X12 , Agfa Cr Film (Dt2B)(1X100) 8X10 , Agomelatine Tablet 25 Mg , Airway Set Size 2, ( Single Unit) , Airway Set Size 3, ( Single Unit) , Airway Set Size 4, ( Single Unit) , Airway Set Size 5, ( Single Unit) , Albendazole Chewable Tablet 400 Mg , Albendazole Oral Suspension 200 Mg/5 Ml,10 Ml Bottle , Alfacalcidol Soft Gelatin Capsule 0.25 Mcg , Alkalizer Mb6 500Ml (Potassium Citrate Magnisum Citrate Syrup & Vit B6) , Allopurinol Tablet 100 Mg , Alprazolam Tablet 0.25 Mg , Alprazolam Tablet 0.5 Mg , Aluminium Hydroxide 240 Mg + Magnesium Hydroxide 100Mg+ Simethicone 25 Mg + Magnesium Carbonate 60 Mg Chewable Tablet , Ambu Bag Adult, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 7 K Pa ( 70 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 1300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Ambu Bag Ped, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 4 K Pa ( 40 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Amikacin Injection 250Mg/ Ml, 2 Ml Vial (500Mg) , Amikacin Injection 50 Mg/ Ml, 2 Ml Vial (100Mg) , Amino Acid Iv Infusion Minimum 10 Essential Amino Acids, 200Ml Bottle , Aminophylline Injection 25 Mg/ Ml, 10 Ml Ampoule , Amiodarone 50Ml /Ml 3Ml Vail Inj. , Amiodarone Tablet 100 Mg , Amisulpride Tablet 50 Mg , Amitriptyline Tablet 10 Mg , Amitriptyline Tablet 25 Mg , Amlodipine Tablet 10 Mg , Amlodipine Tablet 5 Mg , Amoxicillin + Clavulanic Acid Injection 1.2 Gm , 10 Ml Vial , Amoxicillin + Clavulanic Acid Injection 250 Mg +50 Mg, Vial , Amoxicillin + Pottasium Clavulanate Dispersible Tablet 200 Mg +28.5 Mg , Amoxicillin + Pottasium Clavulanate Tablet 500 Mg + 125 Mg , Amoxicillin Capsule 250 Mg , Amoxicillin Capsule 500 Mg , Amoxicillin Oral Suspension 125 Mg/5 Ml, 30 Ml Bottle , Amoxicillin Oral Suspension 125 Mg/5 Ml, 60 Ml Bottle , Amphotericin B Powder For Injection 50 Mg And Vial Has Sodium Deoxychlolate Or Liposomal Complex , Ampicillin Sodium Injection 500Mg 2 Ml Vial , Anterior Chamber Kellmann Multi Flex 4 Point Fixation Type Optical Diameter 6Mm,Overall Length 12.5 Mm, Dioptric Range 10D To 30 D , Anterior Chamber Pmma Iol Optical Diameter 5.25Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D , Anterior Chamber Pmma Iol Optical Diameter 6 Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D , Anti Hemophillic Factor Ix Vial Injection Size 500 /600 Iu , Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule , Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole , Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 500 Iu,Vial/Ampoule , Anti Rabies Immunoglobulin (Monoclonal) Injection (Equine) 100 Iu/2.5Ml, 2.5Ml Vial , Anti Rabies Immunoglobulin (Monoclonal) Injection (Human) 100 Iu/2.5Ml, 2.5Ml Vial , Anti Rabies Immunoglobulin Injection (Equine) 150 Iu/5Ml, 1500Iu, 5Ml Vial , Anti Rabies Immunoglobulin Injection (Human) 150 Iu/Ml, 2Ml Vial , Anti Rabies Vaccine Single Dose Rabies Vaccine 2.5 Iu Injection, 0.5Ml , Anti Rabies Vaccine Through Id Route, 1 Ml Vials Vaccine 1Ml. , Anticold Drop , Anti-Haemorrhoidal Cream For Piles 20 Gm Tube , Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 150 Mcg/Vial , Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 300Mcg/Vial , Antisnake Venom ( Dry Powder For Polyvalent Solution) Injection Vial With 10 Ml ) , Antisnake Venom ( Dry Powder For Polyvalent Solution) Injection Vial With 10 Ml ) (Bharat Serum) , Aprepitant 120 Mg Tablet/Capsule , Aprepitant 80Mg Tablet/Capsule , Aprons (Lab Coats ) (Small) Full Sleeves , Aprons (Lab Coats ) (Small) Half Sleeves , Aprons (Lab Coats) (Large) Full Sleeves , Aprons (Lab Coats) (Large) Half Sleeves , Aprons (Lab Coats) (Medium) Full Sleeves , Aprons (Lab Coats) (Medium) Half Sleeves , Aripiprazole Tablet 10 Mg , Aripiprazole Tablet 5 Mg , Artesunate 60 Mg Inj. , Artesunate Lumefantrine80Mg/480Mg Tab. , Ascorbic Acid Tablet 500 Mg , Atenolol Tablet 50 Mg , Ateplase Injection 20 Mg , Ateplase Injection 50 Mg , Atomoxitine Capsule 10 Mg , Atorvastatin 10Mg+Acetylsalicylic Acid 75 Mg+Ramipril 5Mg Tablet , Atorvastatin Tablet 10 Mg , Atorvastatin Tablet 20 Mg , Atracurium Besylate Injection 10 Mg/ Ml, 2.5 Ml Amp. , Atropine Eye Drops 1%, 5Ml , Atropine Eye Ointment 1%, 5G , Atropine Injection 0.6 Mg/Ml, 1 Ml Ampoule , Azithromycin 500 Mg Injection , Azithromycin Oral Suspension 20 Mg/Ml , 15 Ml Bottle , Azithromycin Oral Suspension 40 Mg/Ml , 15 Ml Bottle , Azithromycin Tablet 250 Mg , Azithromycin Tablet 500 Mg , Balance Salt Solution (Bss For Eye) , Balance Salt Solution (Bss Solution) - Clearsol , Bandage Contact Lens (Bcl) , B-Complex Tablet , Beclofen Tablet 20 Mg , Beclomethasone +Chloramphenical+Clotimazole+Lignocaine 5 Ml Ear Drops , Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With , Benzoyl Per Oxide Gel 2.5%, 20 Gm Tube , Betahistine Tablet 16 Mg , Betahistine Tablet 8 Mg , Betamethasone Dipropionate Cream 0.1% W/W , 5 Gm , Betamethasone Injection 4Mg/Ml , Bethanecholchloride Tablet 25 Mg , Bicalutamide Tablet 50 Mg , Bimatoprost Eye Drops , Bio Waste Poly Bag Hd/Ldpe Bag As Per Bmw Rules 2016 Thickness More Than 50 Micron/200 Gz, Non-Chlorinate ,Ist Quality/Fresh Material With Printing Bio Hazard Logo,Hospital Use And Haryana Govt Supply Not For Sale (Different Colours) Size-14X17/19X26/25X38/24X24 (Rate Per Kg) , Biotin Tablet 10 Mg , Biphasic Isophane Injection 300 I.U/3Ml, (30/70), 3 Ml Prefilled Syringe (Insulin) , Biphasic Isophane Injection 40 I.U/Ml, (30/70), 10 Ml Vial (Insulin) , Bisacodyl Gastro-Resistant (Enteric Coated/Delayed Release) Tablet 5 Mg , Bisoprolol 5Mg Tablet , Blades For Eye Surgery 2.2 Mm (Crescent) , Blades For Eye Surgery 2.8 Mm (Keratome) , Blades For Eye Surgery 3.0 Mm , Blades For Eye Surgery 3.2 Mm , Blades For Eye Surgery Crescent , Blades For Eye Surgery Implant 5.2 Mm , Blades For Eye Surgery Keratones 3.2 Mm , Blades For Eye Surgery Side Port 15° , Bleaching Powder 1 Kg Packing , Bleaching Powder 25 Kg Packing , Bleomycin Injection 15 Mg, 15 Mg/Ml Vial , Blonanserin Tablet 4 Mg , Bone Cement , Bone Narrow Needle For Neonates 18 G , Bone Tap 3.5 , Bone Tap 4.5 , Bone Tap 6.5 , Bortezomib Injection 2 Mg , Bovine Lipid Extract Surfactant Suspension 5Ml (Cipla/Abbott) , Brain Circuit , Breviteracetam Tablet 50 Mg , Brimonidine+Timolol Eye Drops , Bromocriptine Tablet 2.5 Mg , Brown Tape 2 , Budesonide + Formoterol Inhalation (200 Mcg + 6 Mcg), 120 Mdi , Budesonide Inhalation 200 Mcg/Dose, 200 Mdi/Dpi , Budesonide Nasal Spray 100 Mcg/Dose, Single Unit , Budesonide Respirator Solution For Use In Nebulizer 0.5 Mg, 2Ml Respule , Budesonide Respirator Solution For Use In Nebulizer 1 Mg, 2Ml Respule , Bupivacaine Injection 0.5%, 20Ml Vial (Neon) , Bupivacaine Injection 0.5%, 5Ml Amp.(Neon) , Bupivaccine Heavy 5 Mg With Dextrose Monohydrate 80 Mg/Ml Injection 4 Ml Ampoule (Neon) , Buprinorphine Patch 10 Mg , Buprinorphine Patch 15 Mg , Buprinorphine Patch 5 Mg , Buprinorphine Tablet 0.4 Mg , Buprinorphine Tablet 2 Mg , Bupropion Tablet 150 Mg , Buspirone 5 Mg Tablet , Cabergoline Tablet 0.5 Mg , Caffeine Citrate Injection 20 Mg/Ml (Equivalent To 10 Mg Caffeine Base/Ml) , Caffeine Citrate Oral Sol. 1Ml , Caffeine Citrate Oral Sol. 2Ml , Calamine Lotion 100 Ml Bottle , Calcium Gluconate Injection 100 Mg/Ml, 10 Ml Annual Periodical Maintenance , Calcium Salts 500 Mg+ Vitamin D3 250 Iu Tablet , Calcium Syrup Each 5 Ml Contains Calcium 250Mg, Vitamin D3 125 Iu , Capecitabine Tablet 1000 Mg , Capecitabine Tablet 500 Mg , Carbachol 3 % Opthalmic Solution , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Carbamazepine Tablet 200 Mg , Carbamazepine Tablet 400 Mg , Carbimazole Tablet 5 Mg , Carbolic Acid (Phenol) 400G Anhydrous Form , Carboplatin Injection 150 Mg, 10 Mg/Ml Vial , Carboplatin Injection 450 Mg, 10Mg/Ml Vial , Carboprost Injection 250 Mcg In 1 Ml Amp./ Vial , Carfilzomib Injection 60 Mg , Cariprazine Tablet 1.5 Mg , Carvediolol Tablet 3.125 Mg , Cefadroxil Oral Suspension 125 Mg/ 5Ml, 30 Ml Bottle , Cefepime + Tazobactum 1.125Gm Inj. , Cefixime Oral Suspension 50 Mg/ 5 Ml, 30 Ml Bottle , Cefixime Tablet 200 Mg , Cefoperazone + Sulbactam (1G+1G) Injection , Cefotaxime Injection 250 Mg , Cefotaxime Injection 500 Mg 5 Ml Vial , Cefotaxime Sodium Injection 1 Gm 10 Ml Vial , Cefpodoxime Cv 325 Tab. , Ceftazidime 250Mg Injection , Ceftriaxone Injection 1 G, 10 Ml Vial , Ceftriaxone Injection 250 Mg 2 Ml Vial , Centre Line , Cervical Collar Large Size (Soft) , Cervical Collar Medium Size (Soft) , Cervical Collar Small Size (Soft) , Cetrimide Solution 20% Concrete For Dilution, 500 Ml Plastic Bottle , Cetrizine Syrup 5 Mg/5Ml, 60 Ml , Chest Drain (Adults) , Chest Drain Catheter No. 12 , Chest Drain Catheter No. 14 , Chest Drain Catheter No. 28 , Chest Drain Catheter No. 32 , Chest Tube Drainage With Trocar And Cannula , Chest Tube With Underseal Bag 32 , Chlorhexidine Mouth Wash 0.2% W/V, 100Ml , Chlorhexidine Solution 5% Concrete For Dilution, 500 Ml , Chlorine Pillets/Tablet (Drinkwell) (Rate Per Tablet) , Chloroquine Phosphate Injection 40 Mg/Ml , Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50 Ml Bottle , Chloroquine Phosphate Tablet 250 Mg, Equivalent To 155 Mg Chloroquine Base , Chlorpheniramine Tablet 4 Mg , Chlorpromazine (Hydrochloride) Tablet 100 Mg , Chlorthalidone Tablet 6.25 Mg , Chymotrypsin+ Trypsin (1:6 ) Tablet 100K Au , Cilnidipine Tablet 10 Mg , Cinnarizine Tablet 25 Mg , Ciprofloxacin Eye Drops 0.3%, 10 Ml Plastic Bottle , Ciprofloxacin Eye Drops 0.3%, 5 Ml Plastic Bottle , Ciprofloxacin Injection 2Mg/Ml, 100 Ml Bottle For Infusion Ffs Technology , Ciprofloxacin Opthalmic Ointment 0.3 % 5 Gm Tube , Ciprofloxacin Tablet 250 Mg , Ciprofloxacin Tablet 500 Mg , Ciproflox-D Ear Drops , Cisplatin Injection 10 Mg , Cisplatin Injection 50 Mg, 1 Mg/Ml Vial , Citicoline Tablet 500 Mg , Clanidine 0.2Mg Tab. , Clarithromycin Tablet 500 Mg , Clindamycin 600Mg Inj. , Clindamycin Gel 1% W/W, 10Gm Tube , Clindamycine 300Mg Tab. , Clindipine Tablet 10 Mg , Clinidipine Tablet 20 Mg , Clobazam Capsule 10 Mg , Clobetasol 0.05% + Gentamycin 0.1% Ointment 15 Gm Tube , Clofazimine 100Mg Tablet , Clofazimine 50Mg Tablet , Clomifene Citrate Tablet 50 Mg , Clonazepam Tablet 0.5 Mg , Clonazepam Tablet 1 Mg , Clonidine 0.2Mg Tab. , Clonidine 1Mg/100Mcg Tablet , Clopidogrel Tablet 75 Mg , Clotrimazole 1% W/V + Lignocaine Hydrochloride 2% W/V Ear Drops 5 Ml Vial , Clotrimazole Cream 2% W/W, 15 Gm , Clotrimazole Ear Drops 5 Ml Vial , Clotrimazole Mouth Paint 1% W/V In Propylene Glycone Glycerian Base 15 Ml , Clotrimazole Pessaries 200 Mg , Cloxacillin Capsule 500 Mg , Clozapine Tablet 100 Mg , Clozapine Tablet 50 Mg , Codon Set , Colistimethate Sodium Phosphate 4.5Miu Inj. , Conjugated Estrogen 0.625Mg Tablet , Corugated Drain Sheet , Cotrimazole 1 % + Betamethasone 0.0025% Lotion 15 Ml , Cotrimoxazole (Sulfamethoxazole + Trimethoprim) Tablet 800 Mg + 160 Mg , Co-Trimoxazole (Sulphamethoxazole 200Mg + Trimethoprim 40Mg Per 5 Ml) Oral Liquid, 50Ml , Cotton Bandages 10 Cm X 4 Mtrs , Cotton Bandages 15 Cm X 5 Mtrs , Cotton Bandages 5 Cm X 4 Mtrs , Cotton Gauze Cloth 90 Cm X 18 Mtrs (Min. Wt. 450Gm.) , Cotton Pad 4 Packed , Cotton Pad 6 Packed , Cotton Wool Absorbable Ip 100 Gm (Net Weight) , Cotton Wool Absorbable Ip 30 Gm (Net Weight) , Cotton Wool Absorbable Ip 500 Gm (Net Weight) , Cotton Wool Absorbable Ip 70 Gm (Net Weight) , Cough Expectorent (Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg, 100Ml Bottle , Cough Syrup Ambroxol 15 Mg+ Terbutaline Sulphate 1.25 Mg+ Guaiphenesin 50 Mg+ Menthol 2.5 Mg, 100 Ml Bottle , Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml , Courtery Lead ( Single Unit) , Coutery Pad (Single Unit) , Craner Wire Splint , Crape Bandages Bp 10 Cm X 3.5-4.0 Mtrs , Crape Bandages Bp 15 Cm X 3.5-4.0 Mtrs , Cyano Acrylate Glue , Cyclopentolate Eye Drops 1% W/V , Cyclophosphamide Injection 1000Mg, 1.33Mg/Ml Vial , Cyclophosphamide Injection 500Mg, 10Mg/Ml Vial , Cyclophosphamide Tablet 50 Mg , Cycloscerine 250Mg Tablet , Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) , Cyproheptadine Tablet 4 Mg , Dacarbazine Injection 200 Mg, 10Mg/Ml Vial , Dacarbazine Injection 500 Mg , Daclatasvir 30 Mg Tablet , Daclatasvir 60 Mg Tablet , Dapaglifilozin 10Mg Tablet , Dapaglifilozin 10Mg+Metformin 1000Mg Tablet , Dapaglifilozin 10Mg+Sitagliptin 100Mg+Metformin 1000Mg Tablet , Darifenacin Tablet 7.5 Mg , Dark Eye Glasses , Deferasirox Tablet 500 Mg , Degaralix Injection 240 Mg , Deltamethrin 2.5% Wp Per Kg , Desferrioxamine Injection 500 Mg , Desvenlafaxine Tablet 50 Mg , Developer For X-Ray To Make 13.5 Ltr. Solution , Dexamethasone Injection 4Mg/Ml, 2 Ml Ampoule , Dexamethasone Tablet 0.5 Mg , Dexamethasone Tablet 4 Mg , Dexamethasone Tablet 8 Mg , Dextrose 5 % W/V With Sodium Chloride 0.9% W/V For Intravenous Infusion 500 Ml Ffs Bottle (Dns) , Dextrose Intravenous Infusion Ip 25% W/V, 100 Ml Ffs Bottle , Dextrose Intravenous Infusion Ip 5 % W/V , 500 Ml Ffs Bottle , Dextrose Intravenus Infusion Ip 10% W/V, 500 Ml Ffs Bottle , Diacerein 50 Mg + Glucosamine Sulphate 500 Mg Tablet , Diazepam Injection 5 Mg/Ml, 2 Ml Ampoule , Diclofenac + Paracetamol Tablet 50Mg+325Mg , Diclofenac Gel 1%, 30 Gm Tube , Diclofenac Sodium Gastro-Resistant Tablet 50 Mg , Diclofenac Sodium Injection 25 Mg/Ml, 3Ml Amp. , Diclofenac Supositories 50 Mg , Dicyclomine Oral Solution 10Mg/5Ml , Dicyclomine Tablet 10 Mg , Didecyidimethyl Amonium Chloride And Benzyl C12C16 Alkyl Methyl Chloride Solution Presaturated Wipes , Dienogest Tablet 2 Mg , Digoxin Tablet 0.25 Mg , Dill Oil 0.005Ml+ Fennal Oil 0.0007Ml+Simethicone- 40 Mg 30 Ml Drops , Diltiazem 5Mg/Ml Inj. , Diltiazem Injection 5 Mg/Ml , Diltizem Hydrochloride Tablet 30 Mg (Modified Release), 10*10 , Dilzam Cd90Mg Tab. , Dinoprostone Gel 0.5 Mg, 3 Gm , Disodium Hydrogen Citrate Oral Solution 1.38 -1.45 Gm/ 5 Ml, 100 Ml Bottle , Disposable Adhesive Cannula Fixator , Disposable Air Injection Cannula , Disposable Bed Sheet , Disposable Cap With Elastic , Disposable Drape Sheet/Under Pad/Mollinea Sheet , Disposable Dropper 10 Ml , Disposable Dropper 3 Ml , Disposable Dropper 5 Ml , Disposable Eye Patch , Disposable Eye Sticking Pad (Attached Multilayered) , Disposable Insulin Syringe (Needle 31G) , Disposable Mask With Strings (Triple Layer) , Disposable Needle 16G X 1.5 (1.6 X 38 Mm) , Disposable Needle 18G X 1.5 (1.25 X 38 Mm) , Disposable Needle 21G X 1.5 (0.8 X 38 Mm) , Disposable Needle No. 16 , Disposable Needle No. 21 No. Short 1/2 , Disposable Needle No. 23/24 , Disposable Needle No. 26 , Disposable Needle No.22G X 1 (0.7 X 25/32Mm) , Disposable Ot Apron (Blue/Black Color) , Disposable Ot Table Sheet Plastic , Disposable Shoe Cover , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 6.5 (Isi Mark) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 6.5 (Romson/Healthium/Surgicare) (Isi Mark) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 7 (Isi Mark) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 7 (Romson/Healthium/Surgicare)(Isi Mark) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 7.5 (Isi Mark) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 7.5 (Romson/Healthium/Surgicare)(Isi Mark) , Disposable Sterilized Eye Trolley Sheet (Towel) 120Cm*100Cm , Disposable Surgical Gloves 6 No.(Isi Mark) , Disposable Surgical Gloves 6 No.(Romson/Healthium/Surgicare)(Isi Mark) , Disposable Surgical Gloves 6.5 No.(Isi Mark) , Disposable Surgical Gloves 6.5 No.(Romson/Healthium/Surgicare)(Isi Mark) , Disposable Surgical Gloves 7 No.(Isi Mark) , Disposable Surgical Gloves 7 No.(Romson/Healthium/Surgicare)(Isi Mark) , Disposable Surgical Gloves 7.5 No.(Isi Mark) , Disposable Surgical Gloves 7.5 No.(Romson/Healthium/Surgicare)(Isi Mark) , Disposable Syringe 20 Ml With Needle , Disposable Syringe 50 Cement Concrete With Needle , Disposable Syringes 1 Ml With 26 No. Needle , Disposable Syringes 10 Ml. With Needle , Disposable Syringes 2 Ml With 23/24 No. Needle , Disposable Syringes 2 Ml With 23/24 No. Needle (Dispovan/Romsons) , Disposable Syringes 3 Ml With 23/24 No. Needle , Disposable Syringes 3 Ml With 23/24 No. Needle (Dispovan/Romsons) , Disposable Syringes 5 Ml With 23/24 No. Needle , Disposable Syringes 5 Ml With 23/24 No. Needle (Dispovan/Romsons) , Disulfiram Tablet 250 Mg , Disulfiram Tablet 500 Mg , Divalproex Sodium Tablet 500 Mg , Dobutamine Injection 250Mg/5Ml , Docitaxel Injection 120 Mg, 20Mg/ 0.5 Ml Vial , Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging , Dolutegravir Tablet 50 Mg , Domperidone Suspension 1 Mg/Ml, 30 Ml Bottle , Domperidone Tablet 10 Mg , Donepezil Injection 10 Mg , Donepezil Tablet 10 Mg , Donepezil Tablet 5 Mg , Dopamine Injection 40 Mg/ Ml In 5Ml Ampoule , Dorzolamide Eye Drops , Dothiepin Tablet 25 Mg , Doxofylline Tablet 400 Mg , Doxorubicin (Hydrochloride Powder) Aqueous Solution 10Mg/2Ml , Doxorubicin (Hydrochloride Powder) Aqueous Solution 50 Mg/ 2 Ml Vial , Doxycycline Capsules 100 Mg , Doxylamine Tablet 10 Mg , Drape Sheet For Cssd 2 X2 Mtr. Cotton Cloth Grey Color , Drapes With Drainage Bag 100X80 Cm Double Layered Pre Cut , Draw Sheet/ Ot Sheet, 2 Mtr , Dried Aluminium Hydroxide Gel + Magnesium Hydroxide + Simethicone Oral Suspension 250 Mg+ 250 Mg+ 50 Mg/ 5 Ml, 170 Ml Bottle , Drotaverine Injection 40 Mg/ 2 Ml , Drotaverine Tablet 80 Mg , Duloxetine Tablet 30 Mg , Dyna Plast Adhesive Tape Roll (10 Cm*4Mtr) , Ecg Electrodes (Adult) , Ecg Electrodes (Disposable Kit) , Ecg Electrodes (Neonate) , Ecg Jelly 200Ml Bottle , Ecg Paper 215 Mm*20 Mtr, Roll , Ecg Paper 50 Mm*20 Mtr, Roll , Ecg Paper 60 Mm* 15 Mtr, Roll , Ecg Paper 80Mm*20 Mtr Roll , Ecg Paper A4 Size (Edan Machine) , Elemental Iron 60 Mg +Folic Acid 500 Mcg, Sugar Coated And Red Color Tablet , Eltrombopag 25 Mg Tab. , Eltrombopag 50Mg Tab. , Empagliflozin Tablet 10 Mg , Endotrocheal Tube 2 Cuffed , Endotrocheal Tube 2 Uncuffed , Endotrocheal Tube 2.5 Cuffed , Endotrocheal Tube 2.5 Uncuffed , Endotrocheal Tube 3 Cuffed , Endotrocheal Tube 3 Uncuffed , Endotrocheal Tube 6.5 Cuffed , Endotrocheal Tube 6.5 Uncuffed , Endotrocheal Tube 7 Cuffed , Endotrocheal Tube 7 Uncuffed , Endotrocheal Tube 7.5 Cuffed , Endotrocheal Tube 7.5 Uncuffed , Endotrocheal Tube No. 3.5 Cuffed , Endotrocheal Tube No. 3.5 Uncuffed , Endotrocheal Tube No. 4 Cuffed , Endotrocheal Tube No. 4 Uncuffed , Endotrocheal Tube No. 4.5 Cuffed , Endotrocheal Tube No. 4.5 Uncuffed , Endotrocheal Tube No. 5 Cuffed , Endotrocheal Tube No. 5 Uncuffed , Endotrocheal Tube No. 5.5 Cuffed , Endotrocheal Tube No. 5.5 Uncuffed , Endotrocheal Tube No. 6 Cuffed , Endotrocheal Tube No. 6 Uncuffed , Endotrocheal Tube No. 8 Cuffed , Endotrocheal Tube No. 8 Uncuffed , Enema , Enoxaprin Sodium Injection 40 Mg In Pfs , Enoxaprin Sodium Injection 60 Mg In Pfs , Entecavir 0 .5 Mg Tablet , Entecavir 1 Mg Tablet , Epidural Set Caudal , Epidural Set Interlaminar , Epidural Set Transforaminal , Epirubicin Injection 10 Mg, 2Mg/Ml Vial , Epirubicin Injection 50 Mg, 2Mg/Ml Vial , Erlotinib Tablet 100 Mg , Erythromycin Syrup 125 Mg/5 Ml, 60 Ml , Erythromycin Tablet 250 Mg , Erythropoietin Injection 4000 Units/Ml, Single Dose 1 Ml Vial , Erythropoietin Injection 40000 Units/Ml, Single Dose 1 Ml Vial , Escitalopram Tablet 10 Mg , Estrogens Cream 0.625 Mg , Ethambutol 100Mg Tablet , Ethambutol 400Mg Tablet , Ethambutol 800Mg Tablet , Ethamsylate Injection 250 Mg/2 Ml , Ethinyestradiol Tablet 5 Mcg , Ethionamide 250Mg Tablet , Etizolam Tablet 0.50 Mg , Etophylline + Theophylline Injection 169.4 Mg + 50.6 Mg/2 Ml Ampoule , Etophylline + Theophylline Tablet 231 Mg + 69 Mg (Sr) , Etoposide Capsule 50 Mg , Etoposide Injection 100Mg, 20Mg/Ml Vial , Etoricoxilb Tablet 90 Mg , Eustachian Tube Cathetor , Examination Gloves M/L/Xl , Exemestene Tablet 1 Mg , Eye Drapes (Sheet) 80X70 Cm Pre Cut , Eye Drapes (Sheet)100X80 Cm Pre- Cut , Eye Wipes (Sterilized) , Faropenem 300Mg Tab. , Faropenem 200Mg Tab. , Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule , Ferrous (Iron Sucrose) Injection 20 Mg/Ml, 5Ml Annual Periodical Maintenance , Ferrous Sulpahte + Folic Acid Syrup 100 Mg + 0.5 Mg/ 5 Ml, 50 Ml Bottle, Ropp Cap Bottle With Inert Liner & Bottle To Be Provided With A Dispenser To Dispense To 1 Ml Each Time And Packed In A Mono Carton , Filgrastim Injection 300Mcg, 300Mcg/0.5 Ml Prefilled Syringe , Fixer For X-Ray To Make 13.5 Ltr. Solution , Flouromethalone Eye Drops 0.1 % W/V,5 Ml Vial , Fluconazole 2Mg/Ml, 100Ml Infusion , Fluconazole Tablet 150Mg , Fluconazole Tablet 200 Mg , Flunarazine Tablet 10 Mg , Fluorescein Strips For Eye , Fluorouracil Injection 500Mg, 50Mg/Ml Ampule, 10 Ml , Fluoxetine Capsule 20 Mg , Fluphenazine Injection 25 Mg, 1 Ml Ampoule , Flurbiprofen Eye Drops 0.03%, 10 Ml Vial , Fluticasone Cream 0.01 % 10Gm , Fluticasone Furoate Nasal Spray , Fluticasone Furoate (100Mcg) + Umeclidinium (62.5Mcg) + Vilanterol (25Mcg) , Fluvoxamine 150 Mg Tablet , Foleys Catheter 10 , Foleys Catheter 12 , Foleys Catheter 14 , Foleys Catheter 16 , Foleys Catheter 18 , Foleys Catheter 8 , Folic Acid Tablet 5Mg , Formaldehyde Tablet , Formalin Solution / Formaldehyde Solution 5 Ltr. , Framycetin Cream 1%, 30 Gm Tube , Formoterol Fumarate 20Mcg +Budesonide 0.5Mg Respules , Fuji Cr Cassettes 10X12 , Fuji Cr Cassettes 14X17 , Fuji Cr Film (Dt2B)(1X100) 10X12 , Fuji Cr Film (Dt2B)(1X100) 8X10 , Furosemide Injection 10 Mg/Ml, 2Ml Ampoule , Furosemide Tablet 40 Mg , Fusidic Acid Cream 2%, 10Gm Tube , Gabapentin + Nortriptyline (400/10Mg) Tablet , Ganciclovir Eye Ointment , Gattifloxacin Eye Drops , Gattiquin-P Eye Drops , Geftinib Tablet 250 Mg , Gemcitabine Injection 1000Mg, 10Mg/Ml Vial , Gemcitabine Injection 200Mg, 100Mg/Ml Vial , Gentamycin Injection 40 Mg/ Ml, 2 Ml Ampoule , Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle , Glimipride 1Mg+Voglibose 0.3Mg+Metformin 500Mg Tablet , Glimipride 2Mg+Metformin 1000Mg+Sitagliptin 50Mg Tablet , Glimipride 2Mg+Voglibose 0.2Mg+Metformin 1000Mg Tablet , Glimipride Tablet 1 Mg , Glimipride Tablet 2 Mg , Glutraldehyde Solution 2% - 2.5%, 1 Litre Pack , Glutraldehyde Solution 2% - 2.5%, 5 Litre Pack , Glyceryl Trinitrate ( Niroglycerine) Injection 5 Mg/Ml, 5 Ml Ampule , Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms , Glycopyrolate Injection 0.2 Mg/Ml, 1 Ml Ampoule , Glycopyrronium +Formoterol Fumarate Rota Caps , Goserline Injection 10.8 Mg , Granisetron Injection 1 Mg , Granisetron Injection 3 Mg , Green Blade 45 Degree , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 15.5 Cm X 8.5Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 25 Cm X 10 Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 6.5 Cm X 5 Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 15.5 Cm X 8.5Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 25 Cm X 10 Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 6.5 Cm X 5 Cm , Grip Lock , Griseofulvin Tablet 250 Mg , Gum Paint 15 Ml , Haemocogulase (Botrophase) 1Ml Inj. , Halobetasol Propionate + Salicylic Acid 3% Ointment, 20G , Haloperidol Injection 5Mg/1 Ml, 1 Ml Annual Periodical Maintenance , Haloperidol Injection Long Acting 50 Mg , Haloperidol Tablet 5 Mg , Halothane Inhalation 250 Ml Bottle , Halothane Inhalation 30 Ml Bottle , Hand Sanitizer 500 Ml , Hand Wash Solution 5 Ltr , Hand Wash Solution 500Ml , Hard Cervical Collar (Universal) Size , Hcg 5000 Iu(Human Chorionic Gonadotropin) Injection , Hemocoagulase 1Cu, 1Ml Inj (Botropase Type) , Hemocure Hb301 Microcuvetters , Heparin Injection 1%, 5Ml Vial , Hepatitis B Immunoglobulin 100Iu Injection 1Ml. , Hiv Safe Kit , Homatropine Eye Drops 1%, 5Ml , Homide Eye Drops , Hospital Blanket, Red/Blue- Size 60X90 (Rate Per Kilogram) , Human Albumin 20%, 100Ml , Human Milk Fortifier Cashet 1Gm , Human Normal Immunogobin 5% 5Gm , Hyaluronidase Injection 1500 Iu/Ml , Hydro Dissection Cannula 26 No , Hydro Dissection Cannula 27 No , Hydrochlorthiazide Tablet 12.5 Mg , Hydrocortisone (Sodium Sucinate Powder) Injection 100 Mg Vial , Hydrodisection Cannula , Hydrogen Peroxide Solution 6%, 400 Ml Bottle , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +17D To + 25D , Hydroquinone 2%/4% + Tretinoin 0.025 % +Fluocinolone Skin Cream , Hydroquinone 2.0% W/W + Tretinoin 0.025% W/W + Mometasone Furoate 0.1% W/W In A Cream Base Q.S , Hydroxy Propyl Methyl Cellulose Gel 10G , Hydroxychloroquine 200Mg Tab. , Hydroxycobalamin Injection 1 Mg/ Ml, 1Ml Amp. , Hydroxymethyl Starch 6%, 130/0.4 In 0.9% Sodium Chloride Injection 500Ml (Plasma Volume Expander 500Ml) , Hydroxyprogesterone Injection 500 Mg , Hydroxypropyl Methylcellulose Injection 2% , 3 Ml Pfs (Glass Syringe) , Hydroxyzine Hydrochloride Drops 15 Ml Drops , Hydroxyzine Tablet 10 Mg , Hyoscine Butyl Bromide Injection 20 Mg/ Ml, 1 Ml Amp. , Hyoscine Butyl Bromide Tablet 10 Mg , I & A Simcoe 2 Way Cannula , I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye) , I.V. Cannula 18 , I.V. Cannula 20 , I.V. Cannula 22 , I.V. Cannula 24 , I.V. Cannula 26 , I.V. Flow Regulator Extension Sets , I.V.Sets Disposable Adult (Non Air Vent) , I.V.Sets Disposable Adult (With Air Vent) , I.V.Sets Pediatric (With Air Vent) , I.V.Sets Pediatric With Measuring Cylinder , Ibuprofen Oral Solution 100 Mg/5 Ml. 60 Ml Bottle , Ibuprofen Tablet 200Mg , Ibuprofen Tablet 400 Mg , Ichthoimol Glycerine Solution 10 Ml Vial , Ifosfamide Injection 1 Gm , Imatinib Tablet 400 Mg , Imipenem And Cilastatin Injection (500 Mg+500 Mg) , Imipramine Tablet 25 Mg , Immipenum Injection 500 Mg , Infant Feeding Tube 4 , Infant Feeding Tube 5 , Infant Feeding Tube 6 , Infant Feeding Tube 7 , Infant Feeding Tube 8 , Infant Feeding Tube 9 , Infant Formula For Low Birth Weight 400Gm , Infant Formula Lactose Free 400Gm , Infant Formula Milk Std.-I, 200Gm , Insulin (Soluble) Injection 40 Iu/Ml In 10 Ml Vial , Insulin Glargine 100 Iu/Ml, 10Ml , Insulin Glargine 100 Iu/Ml, 3Ml , Intermediate-Acting Insulin (Nph) Injection 40 Iu/Ml In 10 Ml Vial , Intracameral Lignocaine 1% 2Ml Inj , Intracameral Phenylephrine Inj. , Iohexol Injection 300 Mg , Iopar Special Repair Capsule , Ipratropium Respirator Solution For Use In Nebulizer 250Mcg/ 1Ml, 2 Ml Respule , Ipratropium + Levosalbutamol 1.25Mg Respules , Iron Drop , Irrigator Wire For Eye , Isoflurane Inhalation 100 Ml Vial , Isoflurane Inhalation 30 Ml Vial , Isoniazide 100Mg Tablet , Isoniazide 300Mg Tablet , Isophosphamide Injection 200Mg, 100Mg/Ml Vial , Isosorbide Dinitrate Tablet (Sublingual) 5 Mg , Isosorbide Mononitrate Tablet 30 Mg (Sr) , Isotretinoin Capsule 20 Mg , Isoxsuprine Injection 5 Mg/ Ml,2Ml Ampoule , Isoxsuprine Tablet 10 Mg , Ispaghula Granules/ Husk/ Powder 100 Gm , Itraconazole Capsules 200 Mg , Ivabradine 5 Mg Tab. , Ivermectin Tablet 6 Mg , K-90 Catheter , Karman/ Mtp Cannula No. 6, Single Unit , Karman/ Mtp Cannula No. 7, Single Unit , Karman/ Mtp Cannula No. 8, Single Unit , Kellys Pad , Ketaconazole Lotion 2% W/V, 50 Ml , Ketamine (As Hydrochloride) Injection 50 Mg /Ml,10 Ml Vial , Kojic Acid Cream 2 % , Labetalol Tablet 100 Mg , Labetolol Injection 5Mg/Ml, 4Ml Amp. , Lacosamide Tablet 100 Mg , Lacrymal Cannula , Lactase Enzyme Drops , Lactulose Solution 10 Gm/ 15 Ml, 60 Ml Bottle , Lance Tip 15 Degree Blade , Lantus Insulin (Insulin Glargine 100 Units/Ml) , Lantus Insuline Inj. , Latanoprost Eye Drops 0.005 % W/V, 5 Ml , Lenalidomide Tablet 10 Mg , Letrozole Tablet 2.5 Mg , Leucovorin Injection 50 Mg , Levamasole Tablet 150 Mg , Levamasole Tablet 50 Mg , Levetiracetam Tablet 500 Mg , Levitiracetam Inj. 500Mg/5Ml , Levitiracetam Oral Solution , Levocetrizine Tablet 5 Mg , Levodopa + Carbidopa Tablet 100 Mg + 10 Mg , Levofloxacin Tablet 250 Mg , Levofloxacin Tablet 500 Mg , Levosalbutamol Respules 0.31Mg, 2.5Ml , Levosalbutamol Respules 0.63Mg, 2.5Ml , Levosulpride (Sr) 75 Mg + Rabeprazole (Ec) 20 Mg Capsule , Lignocaine 2% Spray , Lignocaine Hydrochloride And Adrenaline Bitartarate Injection 20Mg/Ml And 0.01Mg/Ml Adrenaline, 30 Ml Vial , Lignocaine Hydrochloride And Adrenaline Bitartarate Injection 20Mg/Ml And 0.01Mg/Ml Adrenaline, 30 Ml Vial (Neon) , Lignocaine Injection 2%, 30 Ml Vial , Lignocaine Injection 2%, 30 Ml Vial (Neon) , Lignocaine Jelly 2% W/V (With Seprate Nosal), 30Gm Tube , Linagliptin 5Mg Tablet , Linezolid Inj. 300Ml Infusion , Linezolid Tablet 600 Mg , Lithium Carbonate Tablet 300 Mg , Lithium Tablet 400 Mg Special Repair , Lorazepam Injection 4Mg, 2Ml , Lorazepam Tablet 1 Mg , Lorazepam Tablet 2 Mg , L-Ornithine L-Aspartate 10 Ml Inj. , Losartan-Hz Tablet (50 Mg + 12.5 Mg) , Loteprednol Eye Drops , Lotion/Oint Sumag 75Gm , Loxicard 2%, 50Ml Inj. , Luperolide Injection 22.5 Mg , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 15 Cm X 15 Cm , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 6 Cm X 11 Cm , Magnesium Sulphate Injection 1 Gm /2Ml (50%W/V), 2 Ml Ampoule , Magnesium Sulphate Injection 2.5 Gm /5Ml(50%W/V), 5 Ml Ampoule , Malathion Technical 95%, Per Kg , Mannitol Intravenous Infusion 20% W/V, 100Ml Ffs Technology , Mcs Kit (Meril) , Mdi Tiotropium , Medical X-Ray Films(1X50) 10X12 , Medical X-Ray Films(1X50) 12X15 , Medical X-Ray Films(1X50) 8X10 , Medroxyprogesterone Tablet 10 Mg , Mekentosh Rubber Rate Per Meter , Melatonin Tablet 3 Mg , Memantine Tablet 5 Mg , Mephenamic Acid + Dicyclomine Tablet 500 Mg +20 Mg , Mephentramine Injection 10Ml , Mephentramine Injection 30 Mg/Ml, 1 Ml Amp. , Merocel Nasal Dressing 10 Cement Concrete , Merocel Nasal Dressing 8 Cement Concrete , Merocel Spears For Eye , Meropenum Injection 125 Mg , Meropenum Injection 1Gm , Meropenum Injection 500 Mg , Mesna Injection 400 Mg , Metformin 500Mg+Glimipride 4Mg Tablet , Metformin Tablet 1 Gm , Metformin Tablet 500 Mg , Metformin Tablet Special Repair 1 Gm , Metformin Tablet Special Repair 500Mg , Methotrexate 10Mg Tab. , Methotrexate 5 Mg Tab , Methotrexate Injection 50 Mg , Methotrexate Tablet 2.5 Mg , Methotrexate Tablet 50 Mg , Methoxsalen Tablet 10 Mg , Methyl Ergometrine Injection 200 Mcg In 1 Ml Ampoule , Methyl Ergometrine Tablet 125 Mcg , Methyl Prednisolone Injection 1Gm, 1 Gm Vial With , Methylcobalamin Tablet 1500 Mcg , Methylcobalamine Inj. , Methyldopa Tablet 250 Mg , Methyldopa Tablet 500 Mg , Methylphenidate Tablet 5 Mg , Metoclopramide Injection 5 Mg/Ml, 2 Ml Ampoule , Metoclopramide Tablet 10 Mg , Metoprolol Tablet (Sr) 50 Mg , Metronidazole I.V Infusion 5 Mg/Ml, 100 Ml Bottle For Infusion (Ffs Technology) , Metronidazole Suspension 200Mg/5Ml , 60 Ml Bottle , Metronidazole Tablet 200 Mg , Metronidazole Tablet 400 Mg , Micro Drip Set , Micronized Progesterone Tablet 200 Mg , Micropore/Surgical Paper Tape 25Mm X 9.1Mtr. , Micropore/Surgical Paper Tape 50Mm X 9.1 Mtr. , Micropore/Surgical Paper Tape 75Mm X 9.1 Mtr. , Microsucrion Tip 5-7 Cm Working Length ( 1 Mm To 3 Mm) , Midazolam Injection 1 Mg/Ml, 5 Ml Vial , Mifepristone Tablet 200 Mg , Mifepristone Tablet 25 Mg , Minoxidil Solution 5% , Mirabegron Tablet 50 Mg , Mirtazapine Tablet 15 Mg , Misoprostol Tablet 200 Mcg , Misoprostol Tablet 25 Mcg , Mitomycin Injection 40 Mg , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm , Mometasone + Terbinafine Ointment , Mometasone Furoate Cream 0.1 % W/W , Monteleukast Tablet 5 Mg , Morphine Injection 10 Mg/Ml, 1 Ml Ampoule , Morphine Tablet 10 Mg , Morphine Tablet 20 Mg , Morphine Tablet 30 Mg Special Repair , Mouth Ulcer Gel, 10 Ml Packing , Moxiflocacin 400Mg Tablet , Moxifloxacin + Ketorlac Ear Drops 5 Ml , Moxifloxacin Eye Drops , Moxifloxacin Eye Ointment , Moxiflur Intracameral Inj. For Eye , Moxonidine 0.3Mg Tab. , Mr Cannula No. 5,6,7,8 , Mucous Suction Trap/Mucus Extractor , Multi Electrolyte Injection (Isolyte P Multiple Electrolyte & Dextrose Injection Type 1 ), 500 Ml Ffs Bottle , Multi Vitamin Injection 10 Ml , Multi Vitamin Syrup With Trace Elements 100Ml , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 15Cm X 15 Cm Square (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Multivitamine Drops , Mupirocin Ointment 2% W/W, 22 Gm Tube , N- Acetyl Cysteine Taurine Tab. , N- Acetylcysteine Tablet 600 Mg , N-95 Masks , Naloxone Injection 400 Mcg/Ml, 1Ml Ampoule , Naltrexone Tablet 50 Mg , Nasal Prongs (Adult) , Nasal Prongs (Neonantal) , Nasal Prongs (Ped.) , Nasal Suction Lip Size-1-4 (Working Length -15 Cm) , Natamycin Eye Drops 2%, 5 Ml , Nebivalol Tablet 5 Mg , Nebulisation Set (Mask With Tubing With Chamber (Adult ) , Nebulisation Set (Mask With Tubing With Chamber (Paediatric ) , Negative Suction Catheter , Negative Suction Drain No. 16 , Negative Suction Drain No.14 , Neosporin Eye Ointment , Neostigmine Injection 500 Mcg/ Ml, 5 Ml Ampoule , Nepafenac Eye Drops , Netilmycin Injection 25Mg/Ml , Nicorandil 5Mg Tab. , Nicotin Chewgum 2 Mg , Nicotin Chewgum 4 Mg , Nicotine Pastilles 2 Mg , Nicotine Pastilles 4 Mg , Nicotine Patches , Nifedipine Capsule (Sublingual) 5 Mg (Depin) , Nifedipine Tablet Ip Sr/Er 10 Mg , Nitrile Gloves Blue/White/Black/Grey (M/L/Xl Size) , Nitrofurantoin Capsule 100 Mg , Nitroglycerine 2.6Mg Tab. , Nitrous Oxide Inhalation , Nor Adernaline Injection 4Mg/Ml , Norethisterone Tablet 5 Mg , Normal Saline (Sodium Chloride) Injection 0.9% W/V, 500 Ml Bottle ( Ffs Technology) , Normal Saline (Sodium Chloride) Injection Solution 0.9% Isotonic, 100Ml , Normal Saline Injection 3% 100Ml , Nrm Mask , Octopus Arc-Biannual Rate Contract Connector (Length 1-10 Cm 1.5*2.5, 2-10 Cm 1.5*2.8)Pur Vol- 0.57 Ml , Octreotide Injection 100 Mcg/Ml, Single Dose 1 Ml Vial , Ofloxacin Tablet 200 Mg , Oint Rashfree/Zinc Oxide 20% Ointment , Oint Thrombophob 20Gm , Olanzapine Injection 10 Mg , Olanzapine Injection 210 Mg Long Acting , Olanzapine Injection 300 Mg Long Acting , Olanzapine Injection 405 Mg , Olanzapine Tablet 10 Mg , Olanzapine Tablet 20 Mg , Olmesartan 20 Mg + Amlodipine 5 Mg + Hydrochlorothiazide 12.5 Tablet , Olopatadine 0.1% Eye Drops 5 Ml , Omeprazole Capsule 20 Mg , Ondansetron Injection 2Mg/Ml ,2Ml Ampoule , Ondansetron Oral Liquid 2 Mg/ 5 Ml , Ondansetron Tablet 8 Mg , Opsite Eye Drape Sheet 70 Cm X 70 Cm , Optical Flat 8-Cap Strips 0.2Ml Tube Strips , Oral Glucose 75 Gm , Oral Rehydration Salts Powder For 1000 Ml Solution , Oral Rehydration Salts Powder For 200 Ml Solution , Oranin O 25Gm , Ortho Toludine Reagent 500Ml (O.T. Solution) , Orthopadding Cast/Zigzag Cotton Roll 4 , Orthopadding Cast/Zigzag Cotton Roll 6 , Oseltamivir Syrup (Each 1 Ml Reconstituted Suspension Contain 12 Mg Oseltamivir, 75 Ml Bottle) Syrup , Oseltamivir Tablet 30 Mg , Oseltamivir Tablet 45 Mg , Oseltamivir Tablet 75 Mg , Ot Apron Cloth With Front Plastic Sheet , Ot Gown Poplin Length 130 X 135 Cms Arms Length 58 X 60 Back Open Type With Provision Of Tying With String At Back Arm Should Have Elasting Cuff Or Cord For Tying At Cuff End. The Inside Of Gown Should Be Inter Lock So That There Are No Loose Threads , Ot Sponges With Radio-Opaque Thread (With 8 Layers 30 Cm X 30 Cm ) , Oxaliplatin Injection 100Mg, 5Mg/Ml Vial , Oxaliplatin Injection 50Mg, 5Mg/Ml Vial , Oxygen Connector Both Side Open , Oxygen Hood For Neonates , Oxygen Mask Adult , Oxygen Mask Ped. , Oxygen Tubing, Suction Tubing (Different Colours) , Oxytocin Injection 5 Iu In 1 Ml Ampoule , Paclitaxel Injection 260Mg, 10Mg/1.67 Ml Vial , Paediatric Eye Band , Pantoprazole + Domperidone Special Repair (40Mg+30Mg) Capsule , Pantoprazole Injection 40 Mg, Vial , Paracetamol Drops 150Mg/Ml, 10 Ml Vial With Marked Dropper , Paracetamol Infusion 100 Mg/ 10 Ml, 100Ml Pack , Paracetamol Injection 150 Mg/Ml, 2 Ml Amp. , Paracetamol Peadiatric Syrup 125Mg/ 5Ml, 60 Ml Bottle , Paracetamol Tablet 500 Mg , Paraffin Wax Per Kg. , Paroxetine (Cr) Tablet 25 Mg , Paroxetine Tablet (Cr) 12.5 Mg , Partial Absorble (10X6 Cm)Vicryl Mesh For Ipom , Patient Identification Band Adult Size (Different Colours) , Patient Identification Band Mother & Child Size (Different Colours) , Patient Identification Band Paediatric Size (Different Colours) , Pazopanib Tablet 200 Mg , Peg Filgrastim Injection 6 Mg , Pemetrexate Injection 500Mg, 25Mg/Ml Vial , Pentazocine Injection 30 Mg/ Ml, 1 Ml Ampoule , Perampenel 2 Mg Tablet , Permethrin Cream 5%, 30 Gm , Permethrin Lotion 5%, 50 Ml , Pethidine Injection 50 Mg/Ml, 1Ml Ampoule , Pheniramine Maleate Injection 22.75 Mg/Ml, 2 Ml , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Phenobarbitone Tablet 30 Mg , Phenobarbitone Tablet 60 Mg , Phenobarbitone/Phenobarbital Injection 200 Mg/ Ml , Phenytoin (Sodium) Injection 100Mg, 2Ml Amp. , Phenytoin Oral Solution 25 Mg/Ml, 100 Ml Glass Bottle , Phenytoin Tablet 100 Mg , Phenytoin Tablet 300 Mg , Phytomenadion Injection 1 Mg/0.5 Ml Water Based Single Dose Ampoule , Picc Line 24 G , Picc Line 28 G , Pillow Cover Cotton Size:48 X 70 Cm, Color - (Violet,Indigo, Blue,Green,Yellow,Orange,Peach) , Pilocarpine (Hydrochloride Or Nitrate) Eye Drops 2 %, 5 Ml Squeeze Vial , Piperacillin + Tazobactum 4.5 Gm Injection , Piperacillin 1 Gm + Tazobactum 0.12Gm Injection , Plasma Volume Expander Injection ( Each 100 Ml Contains Polygeline, Polypeptides Of Degaraded Gelatin, Cross Linked Via Urea Bridges 3.5 G ( Equivalent To 0.63 G Of Nitrogen) Nacl Ip 0.85 G, Kcl Ip 0.038 G Cacl2 Ip 0.070G Water For Injection Ip Q.S Electrolytes In M.Mol/Litre, 500 Ml Ffs ( Haemaccel) , Plaster Of Paris Bandages 10 Cm X 2.7 Mtrs , Plaster Of Paris Bandages 15 Cm X 2.7 Mtrs , Plastic Apron For Ot & Labour Room , Pmo Line 200Cm , Pmo Line 50Cm , Podophylline Resin Topical Solution 25% , 10 Ml Bottle , Polyester Green Non Absorable Suture No. 5 Cutting Needle (645) , Polyglactin (Vicryl) 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle(Healthium) (2317) , Polyglactin (Vicryl) 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle (2317) , Polyglactin (Vicryl) 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle (Meril/Relyon/Lotus/B.Braun) (2317) , Polyglactin (Plain) Vicryl Usp 10-0 Spatulated , Polyglactin (Plain) Vicryl Usp 8-0 Spatulated , Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (2346) , Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (Healthium) (2346) , Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (Meril/Relyon/Lotus/B.Braun) (2346) , Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (2347) , Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (Healthium) (2347) , Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (Meril/Relyon/Lotus/B.Braun) (2347) , Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (2437) , Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (Healthium) (2437) , Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (Meril/Relyon/Lotus/B.Braun) (2437) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (Healthium) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (Meril/Relyon/Lotus/B.Braun) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (Healthium) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (Meril/Relyon/Lotus/B.Braun) , Polymide Monofilament Suture 2-0 Cutting Needle (Code 3336) , Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied , Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (Healthium) , Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (Meril/Relyon/Lotus/B.Braun) , Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting , Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (Healthium) , Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (Meril/Relyon/Lotus/B.Braun) , Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied , Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (Healthium) , Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (Meril/Relyon/Lotus/B.Braun) , Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied , Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (Healthium) , Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (Meril/Relyon/Lotus/B.Braun) , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D , Potassium Chloride (Solution) Injectable 15% (150Mg/Ml) , 10 Ml Amp. , Potassium Chloride Oral Solution 10%, 100 Ml Bottle , Potassium Permanganate Crystal For Solution 100 Gm , Pottasium Chloride Syrup , Povidone Iodine 5% Eye Drops , Povidone Iodine Ointment 5%,15 Gm , Povidone Iodine Scrub (Povidone Iodine Cleansing Solution 7.5 %, W/V With Foaming Agent) 500 Ml , Povidone Iodine Solution 10% ,500 Ml , Povidone Iodine Solution 5% ,500 Ml , Pralidoxime (Pam) Injection 1 Gm Vial , Prazosin 5Mg Tab. , Prebiotic Tab. , Prednisolone Sodium Phosphate Eye Drops 1%, 5 Ml , Prednisolone Tablet 10 Mg , Prednisolone Tablet 20 Mg , Pregabalin 75 Mg+ Methylcobalamin 750 Mcg Tablet , Primaquine Tablet 15 Mg , Primaquine Tablet 2.5 Mg , Primaquine Tablet 7.5 Mg , Probiotic Capsule/Tablet (Vizylac/Sporolac)-Lactic Acid Bacilli Spore Not Less Than 300 Million Per Tab/Cap , Prochlorperazine Mouth Dissolving Tablet Flavored Base 5Mg , Prolene Mesh 3X6 , Prolene Mesh 4X6 , Prolene Mesh 6X6 , Promethazine (Hydrochloride) Elixir Or Syrup 5 Mg/5 Ml, 60 Ml Bottle , Promethazine Injection 25 Mg/Ml, 2 Ml Annual Periodical Maintenance , Proparacaine Eye Drops 5 Ml (Paracaine) , Propofol Injection 1% Vial (10 Mg/Ml , 10 Ml Vial) , Propranol Tablet 20 Mg , Propranolol Tablet (Sr) 40 Mg , Protein Powder 400G , Purified Freeze Dried Human Coagulation Factor Viii, Virus Inactivated Injection 250 Iu , Pyrazinamide 750 Mg Tablet , Pyrazinamide 500 Mg Tablet , Pyrethrum Extract 2% (Per Kg) , Pyridium Tablet 200 Mg , Pyridoxine Tablet 10 Mg , Pyridoxine Tablet 100 Mg , Quetiapine Tablet 50 Mg , Quetiapine Tablet Special Repair 100 Mg , Quinine Dihydrochloride Injection 300 Mg/Ml, 2 Ml Ampoule , Quinine Sulphate Tablet 300 Mg , Q-Way 6 Inches ,Sterlized Using Ethylene Oxide , Racecadrotil 100 Mg Tab. , Ramipril Tablet 5 Mg , Ranitidine Injection 25 Mg/Ml, 2 Ml Annual Periodical Maintenance , Ranitidine Syrup 150 Mg/10 Ml , Ranitidine Tablet 150 Mg, Film Coated , Ranolazine 500 Tab. , Ribavirin Capsules 200 Mg , Rifamapicin 150 Mg , Rifamapicin 300 Mg , Rifamapicin 450 Mg , Rifaximin 550Mg Tab. , Ringer Lactate (Solution ) For Injection ( Compound Sodium Lactate) 500 Ml Ffs Bottle , Risperidone Injection Long Acting 25 Mg , Risperidone Tablet 2 Mg , Risperidone Tablet 4 Mg , Rosuvastatin 10 Mg+ Fenofibrates 160 Mg Tablet , Rust Remover From Instruments 1 Ltr Pack , Rust Remover From Instruments 5 Ltr Pack , Ryles Tube 10 , Ryles Tube 12 , Ryles Tube 14 , Ryles Tube 16 , Ryles Tube 8 , Saccharomyces Boulardii 5 Cfu Sachets , Sacubitrol 24 Mg + Vasuram 26 Mg Tab. , Salbutamol Inhaler Areosol 100 Microgram/ Dose, Mdi, Single Packing , Salbutamol Nebulizer /Respirator Sol. 2.5Mg, 2.5Ml Respule , Salbutamol Syrup 2 Mg/5 Ml, 100 Ml Bottle , Salbutamol Tablet 4 Mg , Salicylic Acid Ointment 6%, 15 Gm Tube , Saline Nasal Drops 0.65%, 10 Ml , Sanitary Napkin , Scalp Vein Set No. 22 , Scalp Vein Set No. 23/24 , Scalp Vein Set No. 26 , Septiloc Lotion , Seroglitazar 4Mg Tablet , Sertaconazole Cream 2% W/W, 15 Gm , Sertraline Tablet (Sr) 50 Mg , Sertraline Tablet 100 Mg , Sevelamer 400Mg Tablet , Sevelamer 800Mg Tablet , Sevoflurane Inhalation 250 Ml , Shoulder Immobilizer Standard , Side Port 15 Degree (Antiglare) Green Blade , Side Port 45 Degree (Antiglare) Green Blade , Silk Sutupak Usp 1, 75 Cm , Silk Sutupak Usp 1, 75 Cm (Healthium) , Silk Sutupak Usp 1, 75 Cm (Meril/Relyon/Lotus/B.Braun) , Silk Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle (5036) , Silk Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle (Meril/Relyon/Lotus/B.Braun) (5036) , Silk Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle(Healthium) (5036) , Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting (5037) , Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting (Healthium) (5037) , Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting (Meril/Relyon/Lotus/B.Braun) (5037) , Silk Suture Usp 3-0, 76 Cm X 26 Mm , 3/8 Circle Type Of Needle- Cutting (5028) , Silk Suture Usp 3-0, 76 Cm X 26 Mm , 3/8 Circle Type Of Needle- Cutting (Healthium) (5028) , Silk Suture Usp 3-0, 76 Cm X 26 Mm , 3/8 Circle Type Of Needle- Cutting (Meril/Relyon/Lotus/B.Braun) (5028) , Silk Usp 4-0, With Cutting Needle , Silodosin Tablet 8.0 Mg , Silver Sulfadiazine Cream 1%, 250 Gm Jar , Silver Sulfadiazine Cream 1%, 30 Gm Tube , Simethicone Syrup , Simyl Mct Oil (Medium Chain Triglycerides And Permitted Antioxidants (Tocopherol Accetate) 100Ml , Sitagliptin 100Mg Tablet , Sitagliptin 50Mg Tablet , Skin Traction Set Standard Size , Sodium Bicarbonate 1000Mg Tab. , Sodium Bicarbonate 500Mg Tab. , Sodium Bicarbonate Infusion 7.5% W/V, 10 Ml Ampoule , Sodium Carboxymethyl Cellulose Eye Drops 0.5% W/V, 10 Ml , Sodium Chloride Topical Eye Drops 6% W/W, 5 Ml , Sodium Hypochloride 5% Solution 5 Ltr , Sodium Hypochlorite Solution 10% 5 Ltr , Sodium Valproate Injection 100 Mg/Ml , Sodium Valproate Suspension 200 Mg/5 Ml, 100 Ml , Sodium Valproate/Valproic Acid (Sodium)Controlled Released Tablet 300 Mg , Sodium Valproate/Valproic Acid Enteric Coated Tablet 200 Mg , Sodium Valproate/Valproic Acid Enteric Coated Tablet 500 Mg , Sofosbuvir 400 Mg Tablet , Sofosbuvir 400 Mg Tablet + Ledipasvir 90 Mg Tablet , Sofosbuvir 400Mg+ Velpatasvir 100 Mg Tablet , Soft Roll Dressing (Cast Padding) 4 , Soft Roll Dressing (Cast Padding) 6 , Sorafenib Tablet 200 Mg , Spc Set (Suprapubic Catheter Set) , Spironolactone Tablet 25 Mg , Sterile Cord Clamp Non Toxic, Pyrogen Free Sterile For Single Use Only Single Unit Packing , Sterile Disposable Spinal Needle For Single Use 18 G X 3 1/2 Inch Clear/ Transparent Hub (Dispovan/Romsons/Bd) , Sterile Disposable Spinal Needle For Single Use 22 G X 3 1/2 Inch Clear/ Transparent Hub (Dispovan/Romsons/Bd) , Sterile Disposable Spinal Needle For Single Use 23G X 3 1/2 Inch Clear/ Transparent Hub (Dispovan/Romsons/Bd) , Sterile Disposable Spinal Needle For Single Use 24 G X 3 1/2 Inch Clear/ Transparent Hub (Dispovan/Romsons/Bd) , Sterile Disposable Spinal Needle For Single Use 25 G X 3 1/2 Inch Clear/ Transparent Hub (Dispovan/Romsons/Bd) , Sterile Disposable Spinal Needle For Single Use 26 G X 3 1/2 Inch Clear/ Transparent Hub (Dispovan/Romsons/Bd) , Sterilization Rolls For Packing Instrument 10Cm X 200 Mtrs. (Livral) , Sterilization Rolls For Packing Instrument 15Cm X 200Mtrs (Livral) , Streptokinase Injection Powder 1500000 Iu , Streptomycin Inj 0.75 Gm , Streptomycin Inj 1 Gm , Succinyl Choline Injection 50Mg/Ml, 10Ml Vial , Sucralfate 1Gm With Oxetacain 10Mg/10Ml Suspension , Suction Catheter No. 10 , Single Unit , Suction Catheter No. 16 , Single Unit , Suction Cathetor No. 12 , Suction Cathetor No. 14 , Suction Plain Catheter No. , 8 Disposable Pyrogen Free , Suction Plain Catheter No. 6, Disposable Pyrogen Free , Suction Set/Yankur Set , Suction Tips (Different Sizes No: 2, 3, 4) , Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg , Sulfasalazine Tablet 500 Mg , Sunitinib Tablet 50 Mg , Surgical Blades11 , Surgical Blades15 , Surgical Blades20 , Surgical Blades23 , Surgical Blades24 , Surgical Spirit 500Ml , Surgical Spirit 5Ltr , Surgical Stiching Needle All Sizes (Doctor) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R. Needle (4241) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R. Needle (Meril/Relyon/Lotus/B.Braun) (4241) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R. Needle(Healthium) (4241) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R. Needle (4242) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R. Needle (Meril/Relyon/Lotus/B.Braun) (4242) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R. Needle(Healthium) (4242) , Suture Absorbable Surgical Suture Usp Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 40 Mm, 1/2 Circle Bodied (Healthium) (4259) , Suture Absorbable Surgical Suture Usp Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 40 Mm, 1/2 Circle Bodied (4259) , Suture Absorbable Surgical Suture Usp Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 40 Mm, 1/2 Circle Bodied (Meril/Relyon/Lotus/B.Braun) (4259) , Suture Non-Absorbable Surgical Suture Coated Polyester No. 5 , T- Connector , Tacrolimus Ointment 0.03% W/W, 10 Gm , Tacrolimus Ointment 0.1% , Tamoxifen Citrate Tablet 10 Mg , Tamoxifen Citrate Tablet 20 Mg , Tamsulosin 0.4 Mg + Dutasteride 0.5 Mg Tablet , Tegaderm 2, 3/8 Inch*2.3/4 Inch 6*7 Cm Tegaderm Tm Films Iv Transparent Film Iv Transparent Film Dressing Style(Latex Free) , Telmisartan Tablet 40 Mg , Telmisartan Tablet 80 Mg , Temephos 50% Larvicide Per Litre , Temozolamide Tablet 100 Mg , Temozolamide Tablet 250 Mg , Tenecteplase Injection 20 Mg , Teneligliptin Film Coated Tablet 20 Mg , Tenofovir 300 Mg+ Lamivudine 300 Mg Tablet , Tenofovir Tablet 300 Mg , Terbinafine Tablet 250 Mg , Terlipressin 10Ml Inj. , Test Tube Glass 12X75Mm , Tetanus Toxoid Injection 0.5 Ml Ampoule , Thalidomide Tablet 100 Mg , Thiamine Injection 100 Mg/Ml, 2 Ml Vial , Thiamine Tablet 100 Mg , Thiocolchicoside Capsule 4 Mg , Thiopentone Injection Powder 0.5 G , Thyroxine Tablet 50 Mcg , Timolol Eye Drops 0.5%, 5Ml , Tinidazole Tablet 500 Mg , Tobramycin Eye Drops 0.3% W/V, 5Ml , Toleperisone 150Mg + Diclofenac 50Mg Tablet , Toperamate Tablet 50 Mg , Torasemide Tablet 10 Mg , Tramadol Capsule/Tablet 50 Mg , Tramadol Hydrochloride Capsule/Tablet 100 Mg , Tramadol Injection 50 Mg/Ml, 2 Ml Ampoule , Tranexamic Acid 500 Mg + Mefenamic Acid 250 Mg Tablet , Tranexamic Acid Injection In Water For Injection 100 Mg/Ml, 5 Ml Ampoule , Tranexamic Acid Tablet 500 Mg , Tranylcypromine Tablet 5 Mg , Trastuzumab Injection 150 Mg , Trastuzumab Injection 450 Mg , Traveprost Eye Drops , Tri Luman Cathetor , Triamcinolone Injection 20 Mg/ Ml , Triamcinolone Injection 40 Mg/Ml , Tricholine Citrate 275Mg + Cyproheptadine Hcl 2Mg/5Ml Syrup, 100Ml , Trihexyphenidyl Tablet 2 Mg , Triway (Three Way Stop Clock) Lipid Resistant Pyrogen Free, Sterile, Latex Free , Tropicamide + Phenylepherine Eye Drops 0.8% + 5%, 5 Ml Vial , Tryptan Blue Dye 0.06% W/V, 1 Ml Vial , Ultrasound Jelly 200 Ml Bottle , Umbilical Catheter No. 5, (5 Fr Length 37 Cm, -31Ml/Min Pvc , Umbilical Catheter No. 6 (6 Fr Length 37 Cm, -31Ml/Min Pvc , Urine Bag 2000Ml , Uro Bag (Neonates)- 100 Ml , Ursodeoxycholic Acid Tablet 150 Mg , Ursodeoxycholic Acid Tablet 300 Mg , Valacyclovir 1000Mg Tablet , Valethamate Injection 8 Mg/Ml , Vancomycin Injection 500 Mg , Vancomycine 1Gm Inj. , Vareniciline 0.5Mg Tablet , Vareniciline 1 Mg Tablet , Vecuronium Injection 10 Mg Vial , Venalafaxine Tablet 37.5 Mg , Venalafaxine Tablet 75 Mg , Ventuary Mask , Verapamil Tablet 40 Mg , Vildagliptin Tablet 50 Mg , Vinblastine Injection 10 Mg, 1Mg/Ml Vial , Vincristine Injection 1 Mg, 1Mg/Ml Vial , Viscoelastic 5Ml Vial (Appavisc) , Vitamin A Oral Solution 100000 Iu/Ml, 100 Ml , Vitamin D3 Drops 400 Iu/Ml , Vitamin D3 Tablet (Chewable) 60000Iu , Voglibose 0.3Mg Tablet , Voriconazole Eye Drops , Vortioxetine Tablet 10 Mg , Warfarin (Sodium) Tablet 2 Mg , Water For Injection 5Ml Ampoule , Wax Dissolving Ear Drops, 10 Ml , White Petroleium Jelly 20 Gm , Xylometazoline Nasal Drops 0.05 %, 10 Ml , Xylometazoline Nasal Drops 0.1 %, 10 Ml , Y- Connector For 8-10 Mm , Zinc Sulphate Dispersible Tablet 20 Mg , Zip Lock Poly Bag Different Size Rate Per Kg , Zoledronic Acid Injection 4 Mg , 100 Well Micro Tube Storage Box , 96 Well Reversible Rack F 0.5 To 2.0Ml Vials , Abg Analizer (I Stat) , Abg Card Cg-4 , Abg Card Eg-7 , Absorbent Point No. 15-40 (Dpi/ Dentsply/Gc) , Absorbent Point No. 45-80 (Dpi/ Dentsply/Gc) , Access Opening Kit (Dentsply) , Acetic Acid 2.5Ltr (Nice) , Acetic Acid 500 Ml (Nice) , Acetic Acid 500Ml , Acetone 500 Ml , Acrylic - Trimming Stone/ Bur , Scrubcheck (Tulip) , Scrubcheck (Medsource Ozone) , Drug Abuse Card 6.1 (Tulip) , Pyrocheck (Tulip) , Ada Mtb (Tulip) , Paramax Malaria Card (Tulip) , Hiv+Syphilis Combi (Tulip) , Red Spot Pe Pre-Eclampsia Card (Tulip) , Agar Agar Type 1 (Himedia) 500Gm , Ah Plus (Dpi/ Dentsply/Gc) , Air Rotor Cartridges (Nsk) Supertorque, Standard Head Isi/ Iso/Ce/Marked. , Air- Rotor Diamond Burs No. 1,2,3 (Inverted Bur,Round,Straight,Flame)(Dpi/ Dentsply/Gc) , Air Rotor Spray Bottle , Albumin Kit 5X50Ml (Erba) , Albumin Kit 5X50Ml (J. Mitra) , Albumin Kit 5X50Ml (Tulip) , Alkaline Bile Salt Agar (Himedia) 100Gm , Alkaline Phosphatase Kit Liquix-M 6X6 Ml (Erba) , Alkaline Phosphatase Kit Liquix-M 6X6 Ml (J. Mitra) , Alkaline Phosphatase Kit Liquix-M 6X6 Ml (Tulip) , Amalgam Finishing Kit (Dentsply/Dpi/Gc/Mani) , Amh (Clia) 2*100T (Mindray) , Amh (Clia) 2*50T (Mindray) , Amylase Kit 6*6Ml (Erba) , Analgesic Antiseptic Solution For Dental 20Ml (Pain Off Solution Type) , Anti Ab 1 X 10Ml (Arkray) , Anti Ab 1 X 10Ml (Medsource Ozone) , Anti Ab 1 X 10Ml (Tulip) , Anti Ahg 5 Ml (Arkray) , Anti Ahg 5 Ml(J. Mitra) , Anti Ahg 5 Ml(Tulip) , Anti D 10 Ml (Medsource Ozone) , Anti D 10 Ml (Tulip) , Anti D Blend (Arkray) , Anti D Blend (Tulip) , Anti D Igg/Igm 1 X 10Ml (Arkray) , Anti D Igg/Igm 1 X 10Ml (Tulip) , Anti H 5 Ml (Arkray) , Anti H 5 Ml (Tulip) , Anti H Lectin 1 X 5Ml (Arkray) , Anti H Lectin 1 X 5Ml (Tulip) , Anti Lectin A1 (Arkray) , Anti Lectin A1 (Tulip) , Antibiotic Disc - Cefepime -Tazobactum (Himedia) , Antibiotic Disc - Cefixime - Calvulanic Acid (Himedia) , Antibiotic Disc - Cefoparazone - Sulbactum (Himedia) , Antibiotic Disc - Colistin (Himedia) , Antibiotic Disc - Polymyxin B (Himedia) , Anti-Tg (2*100 T/Kit) (Mindray) , Anti-Tg (2*50 T/Kit) (Mindray) , Anti-Tg Calibrator 3*2Ml Mindrey , Anti-Thyroid Antibodies Control (H)3*2Ml Mindrey , Anti-Thyroid Antibodies Control (L)3*2Ml Mindrey , Anti-Tpo (2*100 T/Kit) (Mindray) , Anti-Tpo (2*50 T/Kit) (Mindray) , Anti-Tpo Calibrator 3*2Ml Mindrey , Apex Elevator (Left) , Apex Elevator (Right) , Arch Bar Length 1Feet Isi/ Iso/Ce/Marked. , Articulating Paper Strip,Red/ Blue Colored With Sufficient Thickness Double Side , Aso Kit (Athenese-Dx) , Aso Kit (Erba) , Aso Kit (J. Mitra) , Aso Kit (Oscar) , Aso Kit (Tulip) , Aso Test Card (Erba) , Aso Test Card (J. Mitra) , Aso Test Card (Tulip) , Auramin-O Dye , Auto Disable Lancet , Automated Extraction Kits (For Thermo Scientifix For Kingfisher Flex Automated Extraction System ,96 Well) Rt-Pcr Lab , Avience Bio Cleaner For Cbc (Mindrey) , Avience Bio Diluent For Cbc (Mindrey) , Avience Bio Lyse For Cbc (Mindrey) , Baindaid Round Per Pc (Hansaplast) , Baindaid Round Per Pc (Peerless) , Ball Burnisher , Band Aid (Regular) , Band Aid (Round) , Bar Code Print Label Roll 50Mm X 25Mm X 100Metres , Basic Fuchsin 25Gm (Nice) , Basic Fuchsin Dye , Bb Splint (Bohler- Braun) , Bc 3D High/Normal/Low( Mindray) , Beaker Glass 1000 Ml , Beaker Glass 2 Ltr , Beaker Glass 250 Ml , Beaker Glass 500 Ml , Bilirubin Kit 60Mlx4 (Erba) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Bioline) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Erba) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Meril) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Oscar) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Ozone) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Sd) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria (Tulip) , Bloating Paper , Blood Agar (Himedia) 100Gm , Blood Agar (Himedia) 200Gm , Blood Agar (Himedia) 500Gm , Blood Bag Double 350 Ml (Hll/Mitra) , Blood Bag Double 350 Ml With Sagm (Hll/Mitra) , Blood Bag Double 450 Ml (Hll/Mitra) , Blood Bag Double 450 Ml With Sagm (Hll/Mitra) , Blood Bag Paed. 100Ml , Blood Bag Quadruple 450 Ml (Hll/Mitra) , Blood Bag Quadruple With Sagm 450 Ml (Hll/Mitra) , Blood Bag Quadruple With Sagm 350 Ml (Hll/Mitra) , Blood Bag Single 350 Ml (Hll/Mitra) , Blood Bag Triple 350 Ml (Hll/Mitra) , Blood Bag Triple 450 Ml (Hll/Mitra) , Blood Bag Triple With Sagm 350 Ml (Hll/Mitra) , Blood Bag Triple With Sagm 450 Ml (Hll/Mitra) , Blood Bag/Cpda Bag 350Ml (Hll/Mitra) , Blood Cell Counter Menual (Alco) , Blood Clotting Time Test Capillary Tube Pack Of 100 , Blood Collecting Safety Syringe , Blood Collecting Safety Syringe (Dispovan/Romsons) , Blood Culture Bottle 20Ml-Glucose Broth ((Himedia) , Blood Culture Bottle 50Ml-Glucose Broth ((Himedia) , Blood Culture Bottle 5Ml-Glucose Broth ((Himedia) , Blood Filter Set , Blood Filter Set With Air Vent , Blood Glucose Kit 2X200Ml (Erba) , Blood Lancets For Glucometer , Blood Urea Kit 20Mlx5 (Athenese-Dx) , Blood Urea Kit 20Mlx5 (Erba) , Bnp (2*100 T/Kit) (Mindray) , Bnp (2*50 T/Kit) (Mindray) , Bnp Calibrator 3*2Ml Mindrey , Bonding Agent For Composite One Bottle Total Etch System (Bottle With Primer +Adhesive) Isi/Iso/Ce Marked , Borosil Reagent Bottle 500Ml , Borosilicate Glass 3 Ltr , Borosilicate Glass 5Ltr. , Brain-Heart Infusion Agar (Himedia) 100Gm , Brain-Heart Infusion Agar (Himedia) 200Gm , Brain-Heart Infusion Agar (Himedia) 500Gm , Brain-Heart Infusion Broth (Himedia) 100Gm , Brain-Heart Infusion Broth (Himedia) 200 Gm , Brain-Heart Infusion Broth (Himedia) 500Gm , Bunsen Burner , C2:1×1.0 Ml Mindrey , Ca125 (2*100 T/Kit) (Mindray) , Ca125 (2*50 T/Kit) (Mindray) , Ca125 Calibrator 3*2Ml Mindrey , Ca15-3 (2*100 T/Kit) (Mindray) , Ca15-3 (2*50 T/Kit) (Mindray) , Ca15-3 Calibrator 3*2Ml Mindrey , Ca19-9 (2*100 T/Kit) (Mindray) , Ca19-9 (2*50 T/Kit) (Mindray) , Ca19-9 Calibrator 3*2Ml Mindrey , Ca72-4 (2*100 T/Kit) (Mindray) , Ca72-4 (2*50 T/Kit) (Mindray) , Ca72-4 Calibrator 3*2Ml Mindrey , Calcium Hydroxide , Paste System Based And Catalyst -Radiopaque (Dentsply/Dpi/Gc) , Calcium Hydroxide + Iodoform Paste For Root Canal Treatment (Meta Biomed/ Pervest/Spetodont) , Calcium Hydroxide Paste In Syringe Isi/Iso/Ce Marked , Calcium Hydroxide, Powder (Dentsply/ Prevest) , Carbol Fuschin Stain/ Zeihl Neelson Stain (Nice) , Cardiac Marker Multi Control (H)3*2Ml Mindrey , Cardiac Marker Multi Control (L)3*2Ml Mindrey , Cassette Holding Tray (20-25 Cassette Holding Capacity) , Catalase Reagent (3% H2O2) 100Ml , Cavity Varnish 5% Sodium Fluoride (Dpi/ Dentsply/ Gc) , Cbnaat Tb Cartridges , Cea (2*100 T/Kit) (Mindray) , Cea (2*50 T/Kit) (Mindray) , Cea Calibrator 3*2Ml Mindrey , Cedar Wood Oil 100Ml , Cefazolin (Himedia) , Cell Counter Paper Roll 57Mm , Cell Counting Chamber / Neubaeur Counting Chamber , Celquant-5 Celquant-5 Detergent 100Ml (Meril) , Celquant-5 Control Level-1, 2.5Ml (Meril) , Celquant-5 Control Level-2, 2.5Ml (Meril) , Celquant-5 Control Level-3, 2.5Ml (Meril) , Celquant-5 Diluent 5Pda, 20Ltr , Celquant-5 Fbh Lyse, 500Ml , Celquant-5 Fdoi Lyse 500Ml (Meril) , Celquant-5 Fdti Lyse 200Ml (Meril) , Cement Plugger (Ss) , Cement Spatula (Ss) , Cement Spreader (Ss) , Centrifuse Digital 12 Tube (Peerless) , Centrifuse Digital 24 Tube (Peerless) , Ceramic Finishing Kit (Dpi/ Dentsply/ Gc/Shofu) , Chloramphenicol (Himedia) , Chocolate Agar (Himedia) 200Gm , Chocolate Agar (Himedia) 500Gm , Chocolate Agar (Himedia) 100Gm , Cholestrol Kit 5 X 20Ml (Athenese-Dx) , Cholestrol Kit 5 X 20Ml (Erba) , Citrate Agar (Himedia) 100Gm , Citrate Agar (Himedia) 200Gm , Citrate Agar (Himedia) 500Gm , Ck-Mb (2*100 T/Kit) (Mindray) , Ck-Mb (2*50 T/Kit) (Mindray) , Ck-Mb Calibrator 3*2Ml Mindrey , Cl-900Ireaction Cuvettes21*2*88=3696 Mindray , Cleaner For Cell Counter Erba H-360, 50Ml. , Cleaner For H-580 , Cleaner For Hematology Analyzer Bc-20S , Cleaner For Rapid-3200, 100Ml , Cleaning Solution Kit For Easylyte Na/K/Cl/Ck , Cled Medium (Himedia) 100Gm , Cled Medium (Himedia) 200Gm , Cled Medium (Himedia) 500Gm , Combiquik Card (Tulip) , Composite Material Syringe (B1, A1, A2) {3M} , Composite Nanohybrid Kit (Dpi/ Dentsply/ Gc) , Conical Flask 1000 Ml , Conical Flask 250 Ml , Conical Flask 250Ml (Borosil) , Conical Flask 500 Ml , Coplin Jar , Coplin Staining Jar (Glass) , Coplin Staining Jar (Plastic) , Copper Sulphate 500Gm , Cortisol (2*100 T/Kit) (Mindray) , Cortisol (2*50 T/Kit) (Mindray) , Cortisol Calibrator 3*2Ml Mindrey , Cotton 400 Gm , Cotton Holder For Dental , Coverslip Size 18*18Mm (1 Unit = 20 Boxes Each 10Gm) Rate Per Unit , Coverslip Size: 22 X 22 Mm (1 Unit = 20 Boxes Each 10Gm) Rate Per Unit , Coverslip Size: 22 X 50 Mm (1 Unit = 20 Boxes Each 10Gm) Rate Per Unit , Coverslip Size: 22 X 60 Mm (1 Unit = 20 Boxes Each 10Gm) Rate Per Unit , Coverslip Size: 24 X 50 Mm (1 Unit = 20 Boxes Each 10Gm) Rate Per Unit , Coverslip Size: 24 X 60 Mm (1 Unit = 20 Boxes Each 10Gm) Rate Per Unit , C-Peptide (2*100 T/Kit) (Mindray) , C-Peptide (2*50 T/Kit) (Mindray) , C-Peptide Calibrator 3*2Ml Mindrey , Cpkmb Kit (Athenese-Dx) , Cpkmb Kit (Erba) , Creatinine Kit 4X60Ml (Erba) , Crom Agar (Himedia) 100Gm , Crom Agar (Himedia) 200Gm , Crom Agar (Himedia) 500Gm , Crp Kit (Erba) , Crp Rapid Card (Athenese - Dx) , Crp Rapid Card (Oscar) , Crp Rapid Card (Tulip) , Cryo Box (Moxcare) , Cryo Box (Tarson) , Cryo Marker , Cryo Tags (Moxcare) , Cryo Tags (Tarson) , Cryo Vial 1.8Ml (Moxcare) , Cryo Vial 1.8Ml (Tarson) , Ct (2*100 T/Kit) (Mindray) , Ct (2*50 T/Kit) (Mindray) , Ct Calibrator 3*2Ml Mindrey , Cyfra21-1 (2*100 T/Kit) (Mindray) , Cyfra21-1 Calibrator 3*2Ml Mindrey , Cyfra21-1V (2*100 T/Kit) (Mindray) , Cyto Fixative , D-Dimer Calibrator Kit For Tulip Turbosmart , D-Dimer Calibrator Kit For Tulip Turbosmart (Athenese -Dx) , D-Dimer Control Kit For Ecl 412 , D-Dimer Control Kit For Tulip Turbosmart , D-Dimer Kit For Tulip Turbosmart , Decalcifying Reagent , Dengue Card Ns1+Ig+Igm Combo (Medsource Ozone) , Dengue Card Ns1+Ig+Igm Combo (Erba) , Dengue Card Ns1+Ig+Igm Combo (Tulip) , Dengue Elisa Kit 96 Test , Dengue Elisa Kit 96 Test (Medsource Ozone) , Dengue Elisa Kit 96 Test (Athenese-Dx) , Dengue Elisa Kit 96 Test (Erba) , Dengue Elisa Kit 96 Test (Meril) , Dengue Elisa Kit 96 Test (Oscar) , Dengue Elisa Kit 96 Test (Sd) , Dengue Elisa Kit 96 Test (Tulip) , Dengue Rapid Test Card , Dengue Rapid Test Card (Bioline) , Dengue Rapid Test Card (Erba) , Dengue Rapid Test Card (Meril) , Dengue Rapid Test Card (Oscar) , Dengue Rapid Test Card (Ozone) , Dengue Rapid Test Card (Sd Biosensor) , Dengue Rapid Test Card (Tulip) , Dental Chair Covering Sterilized Cling Foil Rolls Isi/ Iso/Ce/Marked. , Dental Rvg Sensor Holder/Positioner , Dental Sheet Green Cotton 45 X 45 Cms. , Dental X Ray Machine With 2 Year Warranty And 2 Year Cmc Rate Freezed On 5 % Of Basic Cost , Detergent 1 L/Bottle Mindray , Dhea-S (2*100 T/Kit) (Mindray) , Dhea-S (2*50 T/Kit) (Mindray) , Dhea-S Calibrator 3*2Ml Mindrey , Diamond Marker , Diamond Pencil For Slide Marking , Diluent For Cell Counter Erba H-360, 20Ltr. , Diluent For Hematology Analyzer Bc-20S , Diluent For Rapid-3200, 20Ltr , Disposable Esr Pipette , Disposable Pap Smear Test Sterile Kit , Dna Blood Extraction Kit , Doxycycline (Himedia) , Dropping Bottle 100Ml , Dropping Bottle 250Ml , Dual Cure Resin Cement (Dpi/ Dentsply/ Gc/ Mani) , E2 (2*100 T/Kit) (Mindray) , E2 (2*50 T/Kit) (Mindray) , E2 Calibrator 3*2Ml Mindrey , E3 (2*100 T/Kit) (Mindray) , E3 (2*50 T/Kit) (Mindray) , E3 Calibrator 3*2Ml Mindrey , Eastlyte Tri Level Control , Ecg Gel 1000 Ml , Ecg Gel 250 Ml , Edta 17 % Paste Form (Dpi/ Dentsply/ Gc/ Mani) , Elisa Printing Paper , Elite H 580 Calibrator , Elite H Clean 50Ml , Elite H5 Con H (3Ml) , Elite H5 Con L (3Ml) , Elite H5 Con N (3Ml) , Elite H580 , Diluent 20 Litres , Elite H580 Lyse 1, 500Ml , Elite H580 Lyse 2, 500Ml , Elite H580 Lyse 3, 1Litres , Embedded O Rings 20Pieces , Endo Ice (Dpi/ Dentsply/Gc) , Endo Rotary Files Assorted Pack (Hi Flex) , Endomethasone Paste , Enoxacin (Himedia) , Enteroscreen Typhoid (Tulip) , Erba 4 Channel Ise Cleaning Solution - 5421;6 X 12 Ml , Erba 4 Channel Ise Module Reagent Pack @ 35 Spd;Cal A - 520 Ml / Cal B - 190 Ml (Total 710 Ml) , Erba Ada Cali;1 X 1 Ml , Erba Ada Control;1 X 1 Ml , Erba Ada;1 X 20 Ml /1 X 10 Ml , Erba Albumin Small System Pack;5 X 22 Ml , Erba Albumin;10 X 44 Ml , Erba Alkaline Phosphatase Small System Pack;5 X 22 Ml / 5 X 6.8 Ml , Erba Alkaline Phosphatase;2 X 44 Ml / 2 X 11 Ml , Erba Amylase Small System Pack;5 X 11 Ml , Erba Amylase;5 X 22 Ml , Erba Bilirubin Direct Plus (Dca);6 X 44 Ml / 6 X 12.3 Ml , Erba Bilirubin Direct Small System Pack;5 X 22 Ml / 5 X 6.8 Ml , Erba Bilirubin Direct;6 X 44 Ml / 6 X 12.3 Ml , Erba Bilirubin Total Plus (Dca);6 X 44 Ml / 6 X 12.3 Ml , Erba Bilirubin Total Small System Pack;5 X 22 Ml / 5 X 6.8 Ml , Erba Calcium (A) Small System Pack;5 X 6 Ml , Erba Calcium (A);10 X 12 Ml , Erba Chloride;10 X 12 Ml , Erba Cholesterol Small System Pack;5 X 11 Ml , Erba Cholesterol;10 X 44 Ml , Erba Ck Mb ;2 X 44 Ml / 2 X 11 Ml , Erba Ck Mb Small System Pack;2 X 12 Ml / 2 X 3 Ml , Erba Control H (Aso/Rf/Crp);1 X 1 Ml , Erba Control L (Aso/Rf/Crp);1 X 1 Ml , Erba Creatinine - Enzymatic;5 X 30 Ml / 5 X 10 Ml , Erba Creatinine - Jaffe;5 X 44 Ml / 5 X 11 Ml , Erba Erba Norm;1 X 5 Ml , Erba Erba Norm;4 X 5 Ml , Erba Erba Path;1 X 5 Ml , Erba Erba Path;4 X 5 Ml , Erba Fe 125;R1- 4 X 25 Ml, R2- 2 X 12.5 Ml, Calibrator: 2 X 2 Ml , Erba Ferritin Calibrator;1 X 1 Ml , Erba Ferritin Control High;1 X 1 Ml , Erba Ferritin Control Low;1 X 1 Ml , Erba Ferritin;2 X 14.5/ 2 X 7.7 Ml , Erba Gamma Gt Small System Pack;2 X 22 Ml / 2 X 6.8 Ml , Erba Gamma Gt;2 X 44 Ml / 2 X 11 Ml , Erba Glucose ( God - Pod);10 X 44 Ml , Erba Glucose Hexokinase - Uv;5 X 44 Ml / 5 X 12.5 Ml , Erba Hba1C Cali Set;5 X 0.5 Ml , Erba Hba1C Con H;1 X 0.5 Ml , Erba Hba1C Con L;1 X 0.5 Ml , Erba Hdl Cholesterol With Calibrator;4 X 30 Ml / 4 X 10 Ml , Erba Hdl Kit For Semi Analyser 5X , Erba Ldh - P ;2 X 44 Ml / 2 X 11 Ml , Erba Ldh - P Small System Pack;5 X 11 Ml / 5 X 4 Ml , Erba Ldl Cholesterol With Calibrator;2 X 30 Ml / 2 X 10 Ml , Erba Ldl Kit For Semi Analyser 5X , Erba Lipase Xl (Small System Pack);1 X 44 Ml / 1 X 11 Ml , Erba Lipase Xl;2 X 44 Ml / 2 X 11 Ml , Erba Magnesium;2 X 44 Ml , Erba Micro Albumin Control;1 X 1 Ml , Erba Micro Albumin With Cal;1 X 5 Ml / 2 X 25 Ml , Erba Microprotein With Cal Small System Pack;5 X 6 Ml , Erba Microprotein With Cal;10 X 12 Ml , Erba Phosphorus Small System Pack;5 X 6 Ml , Erba Phosphorus;10 X 12 Ml , Erba Sgot - El Mini;2 X 22 Ml / 2 X 6.9 Ml , Erba Sgot - El;6 X 44 Ml / 6 X 12.5 Ml , Erba Sgot - Hl ;4 X 35 Ml / 4 X 18.1 Ml , Erba Sgot- Hl Small System Pack;5 X 22 Ml / 5 X 11.7 Ml , Erba Sgpt - El Mini;2 X 22 Ml / 2 X 6.9 Ml , Erba Sgpt - El;6 X 44 Ml / 6 X 12.5 Ml , Erba Sgpt - Hl ;4 X 35 Ml / 4 X 18.1 Ml , Erba Sgpt -Hl Small System Pack;5 X 22 Ml / 5 X 11.7 Ml , Erba Total Protein (Two Reagents);4 X 34 Ml / 4 X 17 Ml , Erba Total Protein Small System Pack;5 X 6 Ml , Erba Total Protein;10 X 44 Ml , Erba Triglycerides - Small System Pack;5 X 11 Ml / 5 X 4 Ml , Erba Triglycerides;5 X 44 Ml / 5 X 11 Ml , Erba Uibc 125;R1- 4 X 25 Ml, R2- 2 X 12.5 Ml, Calibrator: 2X 2 Ml , Erba Urea;5 X 44 Ml / 5 X 11 Ml , Erba Uric Acid Small System Pack;5 X 11 Ml / 5 X 4 Ml , Erba Uric Acid;5 X 44 Ml / 5 X 11 Ml , Erba Xl - Aso - Turbilatex With Alibrator (Ita);1 X 22 Ml / 1 X 5.5 Ml , Erba Xl - Autowash Ac/Al Kit;5 X 44 Ml / 5 X 44 Ml , Erba Xl - Multical;4 X 3 Ml , Erba Xl - Rf - Turbilatex With Calibrator (Ita);1 X 22 Ml / 1 X 5.5 Ml , Erba Xl - Rf - Turbilatex With Calibrator (Ita);1 X 22 Ml / 1 X 5.5 Ml (Oscar) , Erba Xl -Crp - Turbilatex With Calibrator (Ita);2 X 22 Ml / 2 X 6.7 Ml , Erba Xl -Crp - Turbilatex With Calibrator (Ita);2 X 22 Ml / 2 X 6.7 Ml (Oscar) , Erba Xl Hba1C With Cali Set;2 X 15 Ml / 2 X 5 Ml , Erba Actime Aptt Kit For Ecl 105 , Erba Actime Aptt Kit For Ecl 412 , Erba Am Kit For Chem-5X , Erba Am Kit For D.I. (Distt. Water) Plant , Erba Am Kit For Em-200 , Erba Am Kit For Em-360/Xl-360 , Erba Autowash - System Pack;10 X 100 Ml , Erba Calcium Chloride For Ecl 105 , Erba Calcium Chloride For Ecl 412 , Erba Chem- 5 (Pm Kit) , Erba D-Dimer Calibrator Kit For Ecl 105 , Erba D-Dimer Calibrator Kit For Ecl 412 , Erba D-Dimer Kit For Ecl 105 , Erba D-Dimer Kit For Ecl 412 , Erba H3 Control Trilevel , Erba Pm Kit For Em-200 , Erba Pm Kit For Em-360/Xl-360 , Erba Protime Ls Control For Ecl 412 , Erba Protime Ls For Ecl 105 , Erba Protime Ls For Ecl 412 , Erba Single Reaction Cuvettes (1000Tests) For Ecl 105 , Erba Single Reaction Cuvettes (1000Tests)For Ecl 412 , Erba Wash For Erba H-360 , Eryscreen 3 X 12Ml (J.Mitra) , Eryscreen 3 X 12Ml (Tulip) , Eryscreen 3 X 5Ml (J.Mitra) , Eryscreen 3 X 5Ml (Tulip) , Eryscreen 4 X 12Ml (J.Mitra) , Eryscreen 4 X 12Ml (Tulip) , Esr Analyser (Erba) , Esr Tube Disposable , Esr Tube Glass (Merienfield) , Esthetic Fiber Post System (Dpi/ Dentsply/ Gc/ Mani) , Etachant Paste (Phosphoric Acid 37%) , Ethanol Absolute 500Ml (Nice) , Ethanol Imported 5 Liter Pack (Nice) , Ethanol Imported 500Ml Pack (Nice) , Eugenol , Explorer -17/23 , Extraction Forceps (Pedo) Lower Anterior , Extraction Forceps (Pedo) Lower Molarmolar , Extraction Forceps (Pedo) Upper Anterior , Extraction Forceps (Pedo) Upper Molar(Left) , Extraction Forceps (Pedo) Upper Molar(Right) , Extraction Forceps Upper Anterior , Extraction Forceps(Adult) Lower Anterior , Extraction Forceps(Adult) Lower Molar , Extraction Forceps(Adult) Lower Premolar , Extraction Forceps(Adult) Upper Anterior , Extraction Forceps(Adult) Upper Cowhorn Anterior , Extraction Forceps(Adult) Upper Molar(Left) , Extraction Forceps(Adult) Upper Molar(Right) , Extraction Forceps(Adult) Upper Premolar , Extraction Forceps(Adult) Upper Root Forceps(Anterior) , Extraction Forceps(Adult) Upper Root Forceps(Posterior)Forceps(Anterior) , Extraction Forceps(Adult) Upper Third Molar , Extraction Forceps(Pedo) Upper Root Forceps(Posterior) , Ferritin (2*100 T/Kit) (Mindray) , Ferritin (2*50 T/Kit) (Mindray) , Ferritin Calibrator 3*2Ml Mindrey , Fiber- Reinforced Splinting Material- Bondable Reinforced Ribben Fiber-Approx 2Mm Width , Fields Stain Solution A Bottle 125 Ml (Nice) , Fields Stain Solution B Bottle 125 Ml (Nice) , Filter Pipette Micro-Tips (Sterile) 10 Ul , Filter Pipette Micro-Tips (Sterile) 20 Ul , Filter Pipette Tips (Sterile) 100 Ul , Filter Pipette Tips (Sterile) 1000 Ul , Filter Pipette Tips (Sterile) 200 Ul , Flowable Composite (Dpi/ Dentsply/ Gc/ Mani) , Fnac Plunger , Fobt Card (Tulip) , Folate (1*100 T/Kit) (Mindray) , Folate (1*50 T/Kit) (Mindray) , Folate Calibrator 3*2Ml Mindrey , Forward And Reverse Grouping Card With Subgrouping In Gel Card (Octopus) (24 Card) 24 Test (Tulip) , Forward And Reverse Grouping Gel Card With Auto Control, (24 Card) 24 Test (Tulip) , Fpsa (2*100 T/Kit) (Mindray) , Fpsa (2*50 T/Kit) (Mindray) , Fpsa Calibrator 3*2Ml Mindrey , Friction Grip Carbide Burs For Cutting (Different Shapes) Isi/Iso/Ce Marked , Friction Grip Carbide Burs For Finishing (Different Shapes) Isi/Iso/Ce Marked , Friction Grip Diamond Burs (Different Shapes) Isi/Iso/Ce Marked , Fsh (2*100 T/Kit) (Mindray) , Fsh (2*50 T/Kit) (Mindray) , Fsh Calibrator 3*2Ml Mindrey , Ft3 (2*100 T/Kit) (Mindray) , Ft3 (2*50 T/Kit) (Mindray) , Ft3 Calibrator 3*2Ml Mindray , Ft4 (2*100 T/Kit) (Mindray) , Ft4 (2*50 T/Kit) (Mindray) , Ft4 Calibrator 3*2Ml (Mindray) , Funnel 3 Inch , Gates Glidden Drill No. 1,2,3 (Dpi/ Dentsply/ Gc/ Mani) , Geimsas Stain Solution Bottle (Nice) , Gel Ball , Gel Bottle (1 Jar) , Glacial Acetic Acid Solution , Glass Ionomer Cement- Type-Ix. 15 Gm Powder+Liquied (Dpi/ Dentsply/ Gc/ Mani) , Glass Jars For Storage Of Specimens With Fixative (1000Ml Capacity) , Glass Jars For Storage Of Specimens With Fixative (100Ml Capacity) , Glass Jars For Storage Of Specimens With Fixative (200Ml Capacity) , Glass Jars For Storage Of Specimens With Fixative (500Ml Capacity) , Glass Jars For Storage Of Specimens With Fixative (50Ml Capacity) , Glass Slab For Mixing Cement 3*5 Inch , Glass Slide Cabinet (1000 Slide Storage Capacity) , Glass Slide For Microscope , Glass Slide Microscope 76Mm X 26Mm , Glass Slide With Concavity (Rate Per Pc) , Gluco Strips -1 Glucometer Free With 1000 Strips , Gluco Strips (Oncall) -1 Glucometer Free With 1000 Strips , Gluco Strips (Kosh-Bio) -1 Glucometer Free With 1000 Strips , Gluco Strips (Ozone) -1 Glucometer Free With 1000 Strips , Gluco Strips (Sd Biosensor) -1 Glucometer Free With 1000 Strips , Gluco Strips (Accusure) -1 Glucometer Free With 1000 Strips , Glucometer , Glucometer (Oncall) , Glucometer (Kosh-Bio) , Glucometer (Ozone) , Glucometer (Sd Biosensor) , Glucometer (Accusure) , Gluquant A1C Hpldbt-01 Kit (400 Test) Rate Per Kit (Meril) , Gluquant A1C Hpldbt-01 Kit (800 Test) Rate Per Kit (Meril) , Graduated Glass Measuring Cylinder 1000Ml , Graduated Glass Measuring Cylinder 500Ml , Gram Stain 100Ml , Gram Stain Kit (Himedia) , Guttapercha Point No. 15-40 (Dpi/ Dentsply/ Gc/ Mani) , Guttapercha Point No. 45-80 (Dpi/ Dentsply/ Gc/ Mani) , H & E Stain (Harris) Powder , Haemoglobin Meter (Round) , Haemoglobin Meter (Sqaure) , Haemoglobin Meter Glass Tube (Round) , Haemoglobin Meter Glass Tube (Sqaure) , Hemostar Coagulometar Xf 1.0 (Tulip) , Hemostar Coagulometar Xf 2.0 (Tulip) , Hemostar 4Ca Coagulometar Automation (Tulip) , Hav Card (Erba) , Hav Card (Tulip) , Hb Cuvett , Hb Meter Digital With One Year Replacement Warranty (Ozone) , Hb Meter Digital With One Year Replacement Warranty (Peerless) , Hb Meter Digital With One Year Replacement Warranty (True Hb) , Hb Meter Digital With One Year Replacement Warranty (Tulip) , Hb Meter Digital With One Year Replacement Warranty (Accusure) , Hb Pipette (Marienfield) , Hb Strips (Ozone) , Hb Strips (Peerless) , Hb Strips (True Hb) , Hb Strips (Tulip) , Hb Strips (Accusure) , Hba1C Kit For C-311 (Roche) , Hba1C Turbosmart Tulip , Hbsag Card For Whole Blood Test , Hbsag Elisa 96 Test , Hbsag Elisa 96 Test (Athenese-Dx) , Hbsag Elisa 96 Test (Medsource Ozone) , Hbsag Elisa 96 Test (Erba) , Hbsag Elisa 96 Test (J.Mitra) , Hbsag Elisa 96 Test (Meril) , Hbsag Elisa 96 Test (Oscar) , Hbsag Elisa 96 Test (Tulip) , Hbsag Rapid Card , Hbsag Rapid Card (Kosh Bio) , Hbsag Rapid Card (Ozone) , Hbsag Rapid Card (Peerless) , Hbsag Rapid Card (Tulip) , Hbsag Rapid Card (Athenese-Dx) , Hbsag Rapid Card (Erba) , Hbsag Rapid Card (J. Mitra) , Hbsag Rapid Card (Meril) , Hbsag Rapid Card (Oscar) , Hbsag Rapid Card (Sd Biosensor) , Hbsag Tridot (Bioline) , Hbsag Tridot (Erba) , Hbsag Tridot (J.Mitra) , Hbsag Tridot (Meril) , Hbsag Tridot (Tulip) , Hcg (2*100 T/Kit) (Mindray) , Hcg (2*50 T/Kit) (Mindray) , Hcg Calibrator 3*2Ml Mindrey , Hcl Concentrated 2.5 Ltr , Hcv Card For Whole Blood Test , Hcv Elisa Kit 96Test , Hcv Elisa Kit 96Test (Athenese-Dx) , Hcv Elisa Kit 96Test (Erba) , Hcv Elisa Kit 96Test (J. Mitra) , Hcv Elisa Kit 96Test (Meril) , Hcv Elisa Kit 96Test (Oscar) , Hcv Elisa Kit 96Test (Medsource Ozone) , Hcv Elisa Kit 96Test (Sd) , Hcv Elisa Kit 96Test (Tulip) , Hcv Rapid (Single Test Card) , Hcv Rapid (Single Test Card ) (Kosh Bio) , Hcv Rapid (Single Test Card ) (Erba) , Hcv Rapid (Single Test Card ) (Meril) , Hcv Rapid (Single Test Card ) (Peerless) , Hcv Rapid (Single Test Card ) (Tulip) , Hcv Rapid (Single Test Card ) Ozone) , Hcv Rapid (Single Test Card) (J.Mitra) , Hcv Rapid (Single Test Card) (Sd) , Hcv Rapid Card (Oscar) , Hcv Tridot (Bioline) , Hcv Tridot (Meril) , Hcv Tridot (Oscar) , Hcv Tridot (Sd Biosensor) , Hcv Tridot (Tulip) , Hepatitis A 96 Test Elisa , Hepatitis A 96 Test Elisa (Athenese-Dx) , Hepatitis A 96 Test Elisa (Erba) , Hepatitis A 96 Test Elisa (J. Mitra) , Hepatitis A 96 Test Elisa (Meril) , Hepatitis A 96 Test Elisa (Oscar) , Hepatitis A 96 Test Elisa (Tulip) , Hepatitis E 96 Test Elisa , Hepatitis E 96 Test Elisa (Erba) , Hepatitis E 96 Test Elisa (Meril) , Hepatitis E 96 Test Elisa (Tulip) , Hev Card , Hev Card (Athenese-Dx) , Hev Card (Medsource Ozone) , Hev Card (Erba) , Hev Card (J. Mitra) , Hev Card (Tulip) , H-Files , Size-15-40 , Length :-21 Mm, Should Have Rubber Stopper (Dpi/ Dentsply/ Gc/ Mani) , H-Files , Size-45-80, Length :-25 Mm Should Have Rubber Stopper (Dpi/ Dentsply/ Gc/ Mani) , Hiv Tridot (Erba) , Hiv Tridot (J.Mitra) , Hiv Tridot (Sd Biosensor) , Hiv Tridot (Tulip) , Hiv 1&2 Card , Hiv 1&2 Card (Athenese-Dx) , Hiv 1&2 Card (Erba) , Hiv 1&2 Card (Meril) , Hiv 1&2 Card (Oscar) , Hiv 1&2 Card (Peerless) , Hiv 1&2 Card (Kosh Bio) , Hiv 1&2 Card (Sd) , Hiv 1&2 Card (Tulip) , Hiv 96 Test Elisa , Hiv 96 Test Elisa (Athenese-Dx) , Hiv 96 Test Elisa (Erba) , Hiv 96 Test Elisa (J.Mitra) , Hiv 96 Test Elisa (Oscar) , Hiv 96 Test Elisa (Ozone) , Hiv 96 Test Elisa (Tulip) , Hiv Card (Ozone) , Hiv Card For Whole Blood Test , Hiv Comb 1+2Immunodot Test Kit 96 Test (Arkery) , Hiv Elisa Kit 96Test Gen-4 (Medsource Ozone) , Hiv Elisa Kit 96Test Gen-4 (Erba) , Hiv Elisa Kit 96Test (Erba) , Hiv Elisa Kit 96Test (Meril) , Hiv Elisa Kit 96Test (Sd) , Hiv Elisa Kit 96Test (Tulip) , Hiv Tridot (J.Mitra) , Hiv Tridot (Meril) , Hiv Tridot (Oscar) , Hybrid Composite Resin For Anteriors Isi/ Iso/Ce/Marked. , Ice-Gel (Cool) Pack (Small) , Immersion Oil For Microscopy, 100X Lens (Himedia)/Nice) , Immunoassay Multi Control (H3*2Ml Mindrey , Immunoassay Multi Control (L)3*2Ml Mindrey , Impression Tray Dentulous U0-U4 L0- L4 , Individual Pcr Tubes 8-Tube Strips(Clear) , Influenza (H1N1) Real Time Pcr Kit (Rate Per Rxn) , Influenza (H1N1) Real Time Pcr Kit (Rate Per Rxn) (3 B-Black Bio) , Influenza (H1N1) Real Time Pcr Kit (Rate Per Rxn) (Altona) , Influenza (H1N1) Real Time Pcr Kit (Rate Per Rxn) (Thermo Fisher) , Inoculating Straight Wire (Nichrome) , Inoculum Loop (Himedia) 1Pc , Inoculum Straight Wire (Himedia) , Insulin (2*100 T/Kit) (Mindray) , Insulin (2*50 T/Kit) (Mindray) , Insulin Calibrator 3*2Ml Mindrey , Internal Filling Solution Kit For Easylyte Na/K/Ck , Iopa Film Size 30 Mm X 40 Mm , Iopa Film Size 31 Mm X 41Mm , Iron Kit For Erba 5X Semi Analyser , Iron Kit (Erba) For Erba Em-360/Em-200 , Iron Profile (Coral) , Jsb Stain I 250Ml (Nice) , K- Files Size- 45-80, Length:-25 Mm, Should Have Rubber Stopper (Dpi/ Dentsply/ Gc/ Mani) , K-Files - Size- 15-40 , Length:-21 Mm , Should Have Rubber Stopper (Dpi/ Dentsply/ Gc/ Mani) , K-Files - Size- 15-40 , Length:-25 Mm , Should Have Rubber Stopper (Dpi/ Dentsply/ Gc/ Mani) , K-Files Size- 6,8,10 Length :- 21 Mm , Should Have Rubber Stopper. (Dpi/ Dentsply/ Gc/ Mani)Pack Of 6 , K-Files Size- 6,8,10 Length :- 25 Mm , Should Have Rubber Stopper. (Dpi/ Dentsply/ Gc/ Mani)Pack Of 6 , Kimberlay Clark Tissue Paper , Kovacs Indole Reagent 3%, 100Ml , Lead & Colour Pencil For Tissue Labeling , Lecrons Wax Carver , Leishman Stain (Modified) Solution 250 Ml (Nice) , Leishman Stain Solution 250 Ml (Nice) , Lentulo Spiral Filler Packet Of 4 (Dpi/ Dentsply/ Gc/ Mani) , Leucoreduced Filter Set (Leukocyte Reduction Filter Set) , Lh (2*100 T/Kit) (Mindray) , Lh (2*50 T/Kit) (Mindray) , Lh Calibrator 3*2Ml Mindrey , Light Cure Ca(Oh)2 Paste (Metabio Med/ Pervest/ Spetodont) , Light Cure Composite Resin-Packable Isi/Iso/Ce Marked , Liquid Paraffin Oil , Liss Solution (Tulip) , Lomefloxacin (Himedia) , Loop Holder (Himedia) 1Pc , Low Profile And High-Profile Disposable Tissue Blades , Low Profile Pcr Cap Strips (12*8*8 Clear) (Bio-Rad) , Low Profile Pcr Tube Strips (12*8*8 Clear) (Bio-Rad) , Lowenstein-Jensen Medium (Lj Medium) (Himedia) , Lpcb Stain (Himedia) , Lugols Iodine 5% 500Ml , Lyse For Cell Counter Erba H-360, 250Ml , Lyse For Cell Counter Erba H-360, 500Ml , Lyse For Hematology Analyzer Bc-20S , Lyse For Rapid-3200, 500Ml , M-20 Cfl Lyse 500Ml Mindray , M20D Mindray , M20P Probe Cleaner Mindray , M-30 Cfl Lyse 500Ml Mindray , M30D Mindray , M30P Probe Cleaner Mindray , M-6 Dr 1000Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Ds 20 Litres , M-6 Fd Dye 12Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Fn Dye 12Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Fr Dye 12Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Ld Lyse 1000Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Lh Lyse 1000Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Ln Lyse 1000Ml For Aspen/Bc 6200 Fully Automatic Cbc Analyser , M-6 Quality Control For Aspen Bc 6200 Fully Automatic Cbc Analyser (Low,High & Normal) , M-68 Ds 20000Ml (Mindray) , M-68 Fd Dye 12Ml (Mindray) , M-68 Lb Lyse 1000Ml (Mindray) , M-68 Ld Lyse 1000Ml (Mindray) , M-68 Lh Lyse 1000Ml (Mindray) , M-68 Probe Cleaner (Mindray) , M-68 Quality Control For Aspen Bc 6800 Fully Automatic Cbc Analyser (Low,High & Normal) , Macconkey Broth (Purple) (Himedia) , Macconkey Broth Purple W/Bcps (Himedia) , Macconky Agar (Himedia) 100Gm , Macconky Agar (Himedia) 200Gm , Macconky Agar (Himedia) 500Gm , Malaria Pan Elisa 96 Test (Erba) , Malaria Pan Elisa 96 Test (J.Mitra) , Malaria Pan Elisa 96 Test (Meril) , Malaria Pan Elisa 96 Test (Tulip) , Manual Dna Extraction Kit (Rate Per Rxn) (Qiagen) , Manual Rna Extraction Kit (Rate Per Rxn) (Qiagen) , Manual Rna Extraction Kit (Size 50 Rxn) (Qiagen) , Matrix 2 Liss 250 Ml , Matrix 2400 Warmer (Erba) , Matrix 2400 Warmer (J.Mitra) , Matrix 2400 Warmer (Tulip) , Matrix Ahg Coombs Test Gel Card Packs (1 X 6 X 24 Card Kit) (Erba) , Matrix Ahg Coombs Test Gel Card Packs (1 X 6 X 24 Card Kit) (J.Mitra) , Matrix Ahg Coombs Test Gel Card Packs (1 X 6 X 24 Card Kit) (Tulip) , Matrix Band , No. 1,8 Toflemire (Dpi/ Dentsply/ Gc/ Mani) , Matrix Band Retainer , No. 1,8 (Dpi/ Dentsply/ Gc/ Mani) , Matrix Cement Concrete 2400 Centrifuge (Erba) , Matrix Cement Concrete 2400 Centrifuge (J. Mitra) , Matrix Cement Concrete 2400 Centrifuge (Tulip) , Matrix Cement Concrete 800 Centrifuge (Erba) , Matrix Cement Concrete 800 Centrifuge (J. Mitra) , Matrix Cement Concrete 800 Centrifuge (Tulip) , Matrix Card Reader (Tulip) , Matrix Liquipap 5 Ml , Matrix Strips,Made From A Thin, Strong, Flexible, Transparent Material Such As Mylar (Dentsply/Dpi/Gc) , May Grunwald Stain Solution Bottle (Nice) , Mct Rack (Tarson) , Mct Tube (Conical Bottom) 1.5Ml (Tarson) , Measuring Scoop For Lab. Salt , Mecillinam (Himedia) , Mercury Pure Triple Distilled , Metabolic Multi Control (H)3*2Ml Mindrey , Metabolic Multi Control (L)3*2Ml Mindrey , Methanol 5 Ltr. (Nice) , Methanol 500Ml (Nice) , Methylene Blue Alkaline (Lofflers) (Nice) , Methylene Blue Dye , Mgg Stain , Micro Centrifuge Tube 1.5Ml , Micro Centrifuge Tube 1.5Ml (Round Bottom) (Moxcare) , Micro Centrifuge Tube 1.5Ml (Round Bottom) (Tarson) , Micro Centrifuge Tube 2Ml (Round Bottom) (Moxcare) , Micro Centrifuge Tube 2Ml (Round Bottom) (Tarson) , Microscope Cover Glass 18Mm, 10 Gms ; English Glass; (Blue Star) , Microscope Cover Glass 18Mm, 10 Gms ; English Glass; (Borosil) , Microscope Cover Glass 18Mm, 10 Gms ; English Glass; (Gem) , Microscope Oil , Microscope Optical Lens Cleaning Solution , Microseal B Adhesive Seal (Pcr Seal) Biorad , Microtips 0 - 200 Microliters (Small) , Microtips 20 - 1000 Microliters (Large) , Microtips Box (2 Ul-200 Ul) , Microtips Box (200 Ul-1000 Ul) , Mineral Trioxide Aggregate Isi/ Iso/Ce/Marked. , Mini Plates Isi/ Iso/Ce/Marked. , Molecular Biology Grade Water As Per Requirement (Distilled Water) 5 Ltr , Molecular Biology Grade Water Zero Tds, 5 Ltr For Laboratory Use , Mouth Mirrors With Ss Handle (Ss) , Muellar Hilton Agar (Himedia) 100Gm , Muellar Hilton Agar (Himedia) 200Gm , Muellar Hilton Agar (Himedia) 500Gm , Multichannel Pipette (12 Channal) Erba , Multichannel Pipette (12 Channal) Thromofisher , Multichannel Pipette (8 Channal) Erba , Multichannel Pipette (8 Channal) Thromofisher , Multidrug Card 10 Parameter , Multi-Sample Vacutainer Blood Collection Needle Single Use (Bd) , Multi-Sample Vacutainer Blood Collection Needle Single Use (Hmd Vaku-8) , Multi-Sample Vacutainer Blood Collection Needle Single Use (Polymed) , Multi-Sample Vacutainer Luer-Lok Access Adapters , Myo (2*100 T/Kit) (Mindray) , Myo (2*50 T/Kit) (Mindray) , Myo Calibrator 3*2Ml Mindrey , N/10 Hcl 500Ml , Netillin (Himedia) , Neubaeur Counting Chamber , Niti Hand Files (21 Mm) Size- 15-40, For Curved Canals (Dentsply/Dpi/Gc) , Niti Root Canal Files K- No 15,20,25 (21 Mm) Pack Of 6 Pcs (Dentsply/Dpi/Gc/Mani) , Niti Root Canal Files K- No 15,20,25 (25 Mm) Pack Of 6 Pcs (Dentsply/Dpi/Gc/Mani) , Nse (2*100 T/Kit) (Mindray) , Nse (2*50 T/Kit) (Mindray) , Nse Calibrator 3*2Ml Mindrey , Nse Control (H)3*2Ml Mindrey , Nse Control (L)3*2Ml Mindrey , Nutrient Agar (Himedia) 200Gm , Nutrient Agar (Himedia) 500 Gm , Nutrient Broth (Himedia) 100Gm , Nutrient Broth (Himedia) 500Gm , Nuclease Free Water 100Ml Koh 10% , Nuclease Free Water 100Ml Koh 20% , Nuclease Free Water 100Ml Koh 40% , Octoplus Complete Grouping Card 24C (Tulip) , Objective (Oil Immersions 100X)(Labo ) , Objective (Oil Immersions 100X)(Olympus ) , Objective (Oil Immersions 10X)(Labo ) , Objective (Oil Immersions 10X)(Olympus ) , Objective (Oil Immersions 40X)(Labo ) , Objective (Oil Immersions 40X)(Olympus ) , Ohp Marker For Slide , Ohp Marker For Slide (Doms) , Ohp Marker For Slide (Luxor) , Oramin O (Nice) , Orthodontics Pliers -Universal , Paraffin Block Cabinet (500 Block Storage Capacity) , Paraffin Wax 500Gm Each (Nice) , Paraffin Wax Small Cubes , Parafilm 2 Inch , Paraldehyde Solution For Sterlization , Path Finder File , Pcr Plates Plastic Case Hard Mounted (Bio-Rad) , Pcs/Box Mindray , Pct (2*100 T/Kit) (Mindray) , Pct (2*50 T/Kit) (Mindray) , Pct Calibratorc0:1×1.2 Ml C1:1×1.0 Ml Mindrey , Pct Control (H)3*2Ml Mindrey , Pct Control (L)3*2Ml Mindrey , Pen For Lancet , Peptone Water (Himedia) 100Gm , Peptone Water (Himedia) 200Gm , Peptone Water (Himedia) 500Gm , Petri Dish 10Cm/100Mm Diameter (Borocil) , Petri Dish 15Cm/150Mm Diameter (Borocil) , Petri Dish 9Cm/90Mm Diameter , Petri Dish 9Cm/90Mm Diameter (Borocil) , Ph Paper , Pipette Shaker , Pit & Fissure Sealant Light Cure, Low Viscosity, Fluoride Releasing Isi/ Iso/Ce/Marked (Dentsply/Dpi/Gc/Mani) , Plaintube 18*150 Mm, 27 Ml (Borosil) , Plastic Container For Storing Buffered Formalin 5Litres , Plasticine , Platlet Diluting Fluid (Nice Comp.) , Pm Kit + Measuring Cell With Refernce Electrode For E-411 (Roche) , Pm Kit For D.I. (Distt. Water) Plant , Pm Kit For Erba H-360 Cell Counter 3 Part , Pm Kit For Erba H-580 Cell Counter 5 Part , Pm Kit For Roche Cobas C311 Fully Automatic Biochemistry Analyzer , Post Extraction Dressing (Prevest/Setodont) , Post Extraction Dressing For Dry Socket (Septodont/Prevest) , Ppa Media (Himedia) , Pre Fabricate Metallic Post (Threaded) (Dentsply/Dpi/Gc/Mani) , Pre Fabricated Metallic Post ( Cemented) (Dentsply/Dpi/Gc/Mani) , Pregnancy Card (Aspen) , Pregnancy Card (Erba) , Pregnancy Card (J.Mitra) , Pregnancy Card (Oscar) , Pregnancy Card (Sd) , Pregnancy Card (Tulip) , Preterm Infant Formula ( 3.41 Gm Protein/100Kcal ) 400Gm , Prl Calibrator 3*2Ml (Mindrey) , Probe Cleanser For Elite H580 Fully Automatic Cbc Analyser, 100 Ml , Probe Cleanser For Fully Automatic Cbc Analyser, 100 Ml , Probe Cleanser For Fully Automatic Cbc Analyser, 1000 Ml , Probe Cleanser For Fully Automatic Cbc Analyser, 50 Ml , Probe Cleanser For Fully Automatic Cbc Analyser, 500 Ml , Prog Calibrator 3*2Ml Mindrey , Progesterone (2*100 T/Kit) (Mindray) , Progesterone (2*50 T/Kit) (Mindray) , Prokan (Pe 6000) Rapid Cbc Analyzer Diluent 20Ltr , Prokan (Pe 6000) Rapid Cbc Analyzer Lyse 500Ml , Prokan (Pe 6000) Rapid Cbc Analyzer Probe Cleaner (Pe1)100Ml , Prokan (Pe 6000) Rapid Cbc Analyzer Probe Cleaner (Pe2)100Ml , Prokan (Pe 6000) Rapid Cbc Analyzer Rinse 10Ltr , Prolactin (2*100 T/Kit) (Mindray) , Prolactin (2*50 T/Kit) (Mindray) , Protaper Gp [F1F2F3] (Dentsply/Dpi/Gc/Mani) , Protaper Hand Files Sx-F3 (Dentsply/Dpi/Gc/Mani) , Protaper Manual Endo Files 21 Mm , Protaper Manual Endo Files 23 Mm , Pth (2*100 T/Kit) (Mindray) , Pth (2*50 T/Kit) (Mindray) , Pth Calibrator 3*2Ml (Mindrey) , Pti Quality Control (Erba) , Pulp Devitalizer (Dentsply/Dpi/Gc/Mani) , Pyrocheck Card, Malaria+ Dengue+Typhoid Combo Card (Tulip) , Quadro Hiv 1-2 Test Ab (Meril) , Quality Control Norm Kit (For Semi Automatic Auto Analyser Erba) , Quality Control Path Kit (For Semi Automatic Auto Analyser Erba) , R.O. Filter Blue (Pre Filter) For Di Plant , Ra Factor Kit Quantitative (Erba) For Erba Em-360/Em-200 , Ra Factor Kit Quantitative (Erba) For Erba H-360 , Ra Factor Kit Quantitative Erba 5X Semi Analyser , Ra Factor Kits , Ra Factor Kits (Athenese-Dx) , Ra Factor Kits (Erba) , Ra Factor Kits (Oscar) , Ra Factor Kits (Tulip) , Ra Factor Rapid Card , Ra Factor Rapid Card (Athenese-Dx) , Ra Factor Rapid Card (Erba) , Ra Factor Rapid Card (J.Mitra) , Ra Factor Rapid Card (Oscar) , Ra Factor Rapid Card (Tulip) , Rack For Elisa Testing (96 Tubes) , Racked Sterile Filtered Microtips(Low Retention) 1000Ul Moxcare , Racked Sterile Filtered Microtips(Low Retention) 1000Ul Tarson , Racked Sterile Filtered Microtips(Low Retention) 100Ul Moxcare , Racked Sterile Filtered Microtips(Low Retention) 100Ul Tarson , Racked Sterile Filtered Microtips(Low Retention) 10Ul Moxcare , Racked Sterile Filtered Microtips(Low Retention) 10Ul Tarson , Racked Sterile Filtered Microtips(Low Retention) 200Ul Moxcare , Racked Sterile Filtered Microtips(Low Retention) 200Ul Tarson , Racked Sterile Filtered Microtips(Low Retention) 20Ul Moxcare , Racked Sterile Filtered Microtips(Low Retention) 20Ul Tarson , Rapid Afb Stain Kit(Erba) , Rapid Afb Stain Kit(J.Mitra) , Rapid Afb Stain Kit(Tulip) , Rapid Antigen Test Card (Covid) , Rapid Cytochrome/Modified Rapid Leishman Stain , Rapid Geimsa Stain Kit , Rapid H & E Stain Kit (Biolab) , Rapid Malaria Stain Kit , Rapid Pap Stain Kit , Rbc Diluting Fluid (Jmitra) , Rbc Diluting Fluid (Nice) , Rbc Folate (2*50 Ml) (Mindray) , Rc Broaches , Reagents Anti-A, Anti- Anti- D Sera 10Ml (Arkery) , Reagents Anti-A, Anti- Anti- D Sera 10Ml (J. Mitra) , Reagents Anti-A, Anti-B, Anti-D Sera (Blood Group Kit) 10Ml (Meril) , Reagents Anti-A, Anti-B, Anti-D Sera (Blood Group Kit) 10Ml (Oscar) , Reagents Anti-A, Anti-B, Anti-D Sera (Blood Group Kit) 10Ml (Tulip) , Reagents Anti-A, Anti-B, Anti-D Sera (Blood Group Kit) 5Ml Arkery) , Reagents Anti-A, Anti-B, Anti-D Sera (Blood Group Kit) 5Ml (Tulip) , Reagents Anti-A1 (Lectin) Serum (Arkary Health Care) , Reagents Anti-A1 (Lectin) Serum (Tulip) , Reagents Anti-Ab Serum (Arkary Health Care) , Reagents Anti-Ab Serum (Tulip) , Reagents Antihuman Globulin Serum (Arkary Health Care) , Reagents Antihuman Globulin Serum (Tulip) , Reagents Bovine Albumin 22% , Redspot Pe Card , Reproductive Multi Control (H)3*2Ml Mindrey , Reproductive Multi Control (L)3*2Ml Mindrey , Resin Bonded Zinc Oxide-Eugenol Cement Isi/Iso/Ce Marked , Restroative Cement Type - Ii - (Powder & Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Shade :- Dark Grey, Pale Yellow, Yellow Brown (Dentsply, Sirona/ Gc/P.D./Dpi) 15 Gm , Rh Phenotype With Anti- K (24 Card) 24 Test (Tulip) , Rifampicin (Himedia) , Rnase And Dnase Degradation Solution , Rnase And Dnase Degradation Solution Wipes , Robertson Cooked Meat Broth (Himedia) 100Gm , Robertson Cooked Meat Broth (Himedia) 200Gm , Robertson Cooked Meat Broth (Himedia) 500Gm , Root Canal Files H- 45-80, 21 Mm Pkt Of Six Isi/Iso/Ce Marked , Root Canal Files H- No. 15,20 (21 Mm) Pkt Of Six Isi/Iso/Ce Marked , Root Canal Files H- No. 15,20 (25 Mm) Pkt Of Six Isi/Iso/Ce Marked , Root Canal Spreader 15-40, 21 Mm (Dentsply/Dpi/Gc/Mani) , Root Canal Spreader 15-40, 25 Mm (Dentsply/Dpi/Gc/Mani) , Rpr Dilution Kit , Rpr/Vdrl Card (50 Test Each) (J Mitra) , Rpr/Vdrl Card (50 Test Each) (Tulip) , Rpr/Vdrl Strips (50 Test Each) (J Mitra) , Rpr/Vdrl Strips (50 Test Each) (Tulip) , Rtpcr Kits For Quantitative Viral Load Test For Hepatitis B Virus (Rate Per Rxn) (Altona) , Rtpcr Kits For Quantitative Viral Load Test For Hepatitis C Virus (Rate Per Rxn) (Altona) , Rubber Dam Kit (Dentsply/Dpi/Gc/Mani) , Rubber Dam Sheet Isi/Iso/Ce Marked , S. Calcium Kit , S. Calcium Kit (Athenese-Dx) , S. Calcium Kit (Erba) , S. Calcium Kit (J. Mitra) , S. Cholesterol Kit (Erba) , S. Cholesterol Kit (J. Mitra) , S. Phosphorus Kit , S. Phosphorus Kit (Athenese-Dx) , S. Phosphorus Kit (Erba) , S. Phosphorus Kit (J. Mitra) , S. Protein Kit 5X50 (Erba) , S. Protein Kit 5X50 (J.Mitra) , Salt Testing Kit , Sample (Auto) 2*30 Ml/Box (Mindray) , Sample (Manual) 6*8 Ml/Box (Mindray) , Sample Cups (Hitachi) , Sample Cups Paediatrics , Saturated Picric Acid Solution , Screw Capped Storage Vial 2Ml (500 Vials) Per Pack 2 Ml , Sd000-1Vl-Ampicillin (Himedia) , Sd013-1Vl-Erythromycin (Himedia) , Sd016-1Vl-Gentamycin (Himedia) , Sd023-1Vl-Nitrofurantoin (Himedia) , Sd028-1Vl-Pencillin-G (Himedia) , Sd035-1Vl-Amikacin (Himedia) , Sd040-1Vl-Cefotaxime (Himedia) , Sd041-1Vl-Cefoxitin (Himedia) , Sd045-1Vl-Vancomycin (Himedia) , Sd057-1Vl-Norfloxacin (Himedia) , Sd060-1Vl-Ciprofloxacin (Himedia) , Sd061-1Vl-Cefuroxime (Himedia) , Sd062-1Vl-Ceftazidime (Himedia) , Sd063-1Vl-Amoxicillin And Clavulanic Acid (Himedia) , Sd065-1Vl-Ceftriaxone (Himedia) , Sd072-1Vl-Cefoparazone (Himedia) , Sd073-1Vl-Imipenem (Himedia) , Sd112-1Vl-Ampicillin/Salbatum (Himedia) , Sd164-1Vl-Clindamycin (Himedia) , Sd204-1Vl-Azithromycin (Himedia) , Sd205-1Vl-Fosfomycin (Himedia) , Sd210-1Vl-Pipercillin/Tazobactum (Himedia) , Sd211-1Vl-Cefixime (Himedia) , Sd212-1Vl-Aztreonam (Himedia) , Sd215-1Vl-Linezolid (Himedia) , Sd216-1Vl-Levofloxacin (Himedia) , Sd219-1Vl-Cefepime (Himedia) , Sd283-1Vl-Doripenam (Himedia) , Sd727-1Vl-Meropenem (Himedia) , Sda Agar (Himedia) 100Gm , Sda Agar (Himedia) 200Gm , Sda Agar (Himedia) 500Gm , Self Polymerizing Acrylic Liquid Isi/Iso/Ce Marked , Self Polymerizing Acrylic Powder Isi/Iso/Ce Marked Pink , Semen Diluting Fluid (Nice) , Semi Auto Analyser Erba Chem 5X , Serum Calcium Kit For Semi Autoanalyser (Erba) , Serum Crp Qualitative Test Kit For Semi Autoanalyser , Serum Crp Qualitative Test Kit For Semi Autoanalyser (Athenese-Dx) , Serum Crp Qualitative Test Kit For Semi Autoanalyser (Erba) , Serum Crp Qualitative Test Kit For Semi Autoanalyser (Oscar) , Serum Crp Quantitative Test Kit For Semi Autoanalyser , Serum Crp Quantitative Test Kit For Semi Autoanalyser (Athenese-Dx) , Serum Crp Quantitative Test Kit For Semi Autoanalyser (Erba) , Serum Crp Quantitative Test Kit For Semi Autoanalyser (Oscar) , Serum Glucose Kit For Semi Autoanalyser , Serum Glucose Kit For Semi Autoanalyser (Athenese-Dx) , Serum Glucose Kit For Semi Autoanalyser (Erba) , Serum Pti Kit (Tulip) , Serum Ra Qualitative Test Kit For Semi Autoanalyser , Serum Ra Qualitative Test Kit For Semi Autoanalyser (Athenese-Dx) , Serum Ra Qualitative Test Kit For Semi Autoanalyser (Erba) , Serum Ra Qualitative Test Kit For Semi Autoanalyser (Oscar) , Serum Separate Tube , Serum Total Protein Kit For Semi Autoanalyser (Athenese-Dx) , Serum Total Protein Kit For Semi Autoanalyser (Erba) , Sgot Kit 5*20Ml (Erba) , Sgot Kit 5*20Ml (J.Mitra) , Sgot Kit 5*20Ml (Tulip) , Sgpt Kit 5*20Ml (Erba) , Sgpt Kit 5*20Ml (J.Mitra) , Sgpt Kit 5*20Ml (Tulip) , Sharp Contener 2 Ltr , Sharp Contener 5 Ltr , Sickle Cell Rapid Test Kit , Sickle Cell Rapid Test Kit (Erba) , Silver Diamine Fluoride 38% Sdf 5Ml , Single Channel Variable Volume Micropipette 0.5-10 Ul (Erba) , Single Channel Variable Volume Micropipette 0.5-10 Ul (Tarson) , Single Channel Variable Volume Micropipette 0.5-10 Ul (Thermo Scientific) , Single Channel Variable Volume Micropipette 02-20 Ul (Erba) , Single Channel Variable Volume Micropipette 02-20 Ul (Tarson) , Single Channel Variable Volume Micropipette 02-20 Ul (Thermo Scientific) , Single Channel Variable Volume Micropipette 05-50 Ul (Tarson) , Single Channel Variable Volume Micropipette 05-50 Ul (Thermo Scientific) , Single Channel Variable Volume Micropipette 05-50 Ul(Erba) , Single Channel Variable Volume Micropipette 100-1000 Ul (Erba) , Single Channel Variable Volume Micropipette 100-1000 Ul (Tarson) , Single Channel Variable Volume Micropipette 100-1000 Ul (Thermo Scientific) , Single Channel Variable Volume Micropipette 10-100 Ul (Tarson) , Single Channel Variable Volume Micropipette 10-100 Ul (Erba) , Single Channel Variable Volume Micropipette 10-100 Ul (Thermo Scientific) , Single Channel Variable Volume Micropipette 20-200 Ul (Erba) , Single Channel Variable Volume Micropipette 20-200 Ul (Tarson) , Single Channel Variable Volume Micropipette 20-200 Ul (Thermo Scientific) , Slide Box , Slide Carrying Tray (20 Slide Capacity) , Slide Labelling Tape Roll , Slide Mountant Dpx , Slide Rack Of Staining Turf , Slide Staining Racks , Slide Storage Box (50 Slide Capacity) , Slide Tissue Adhesive(Hydophillic Slides) (Egg Albumin) , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) , Small Inverted Cone , Small Straight Fissure Bur , Sodium Citrate 3.8%, 500Ml Solution , Sodium Hylanuranate 1.8 % In 1 Ml Pfs , Sodium Hypochlorite (1%) For Dental/Endodntic Irregation 500Ml , Sodium Hypochlorite (3%) For Dental/Endodntic Irregation 500Ml , Sodium Phosphate Dibasic (Na2Hpo4) Buffer , Sodium Phosphate Monobasic (Nah2Po4) Buffer , Solution Pack For Easylyte Na/K/Cl , Spectacle Acetate (Frame With English White Glass Different Colours With Cover) , Spoon Excavator , Sputum Cup With Sticker , Squeaze Bottle 500Ml , Ss Moulds (For Paraffin Embedding) , Sst Gel Tube , Staining Turf With Lid , Sterile Cotton Swab Stick For Culture Sample , Sterile Sample Collection Container , Sterilizable Plastic Box For Endodontic , Storage Vial 5 Ml , Substrate Solution 115 Ml * 4 Mindray , Substrate Solution 75 Ml * 4 Mindray , Sulphuric Acid Con. 2.50 Ltr (Nice) , Sulphuric Acid Con. 500 Ml (Nice) , Supragingival Scaler Set , Surfactant (Synthetic)(25 Mg/1Ml), 1.5Ml , Surfactant (Synthetic)(25 Mg/1Ml), 3 Ml , Surfactant (Synthetic)(25 Mg/1Ml), 5Ml , Syphilis Card Whole Blood (J. Mitra) , Syphilis Card Whole Blood (Oscar) , Syphilis Card Whole Blood (Tulip) , Syphilis Ppha Vdrl Card (Erba) , Syphilis Ppha Vdrl Card (J.Mitra) , Syphilis Ppha Vdrl Card (Ozone) , Syphilis Ppha Vdrl Card (Tulip) , T3 (2*100 T/Kit) (Mindray) , T3 (2*50 T/Kit) (Mindray) , T3 Calibrator 3*2Ml Mindray , T4 (2*100 T/Kit) (Mindray) , T4 (2*50 T/Kit) (Mindray) , T4 Calibrator 3*2Ml Mindray , Tamparary Restorative Material (3M/ Dpi/ Prevest) , Tcbs Agar (Himedia) 100Gm , Tcbs Agar (Himedia) 200Gm , Teicoplanin (Himedia) , Temporary Feeling 30 Gm (Amdent/Orafil -G) , Term Infant Formula ( 70% Whey , L. Reutri ) 200Gm , Term Infant Formula ( 70% Whey , L. Reutri ) 400Gm , Test Tube Glass 12 X75Mm , Test Tube Glass 15X75Mm , Test Tube Plastic , Test Tube Rack 18 Hole (Plastic) , Test Tubes Brush , Testo Calibrator 3*2Ml Mindrey , Testosterone (2*100 T/Kit) (Mindray) , Testosterone (2*50 T/Kit) (Mindray) , Tetracycline (Himedia) , Tg (2*100 T/Kit) , Tg (2*100 T/Kit) (Mindray) , Tg (2*100 T/Kit) (Athenese-Dx) , Tg (2*50 T/Kit) , Tg (2*50 T/Kit) (Mindray) , Tg (2*50 T/Kit) (Athenese-Dx) , Tg Calibrator 3*2Ml Mindrey , Thphoid (Igg + Igm) Card (Erba) , Thphoid (Igg + Igm) Card (Tulip) , Thphoid (Igm) Card (Erba) , Thphoid (Igm) Card (Oscar) , Thphoid (Igm) Card (Ozone) , Thphoid (Igm) Card (Tulip) , Three Part Analyser Erba H-360 , Thyroid Function Multi Control (H)3*5Ml Mindrey , Thyroid Function Multi Control (H)6*5Ml Mindrey , Thyroid Function Multi Control (L)3*5Ml Mindrey , Thyroid Function Multi Control (L)6*5Ml Mindrey , Tibc Kit For Erba 5X Semi Analyser , Tina Hcg (Tulip) , Tissue Block Holders For Microtome , Tissue Cutting/Slicing Plastic Board , Tissue Embedding Cassettes (Size: 40X27X7Mm) 3 Colour , Tissue Embedding Moulds (All Sizes) And L-Moulds , Tissue Marking Ink (India Ink)100Ml , Tissue Paper Roll , Tissue Rings , Toffle Matrix Retainer Standard , Tongue Depressor , Tooth Stain Remover 100Ml , Topical Fluoride Apf Gel 1.25% (Dentsply/Dpi/Gc/Mani) , Tourniquet Big Size , Towel 56 X 115 Cms. White Color , Tpsa (2*100 T/Kit) (Mindray) , Tpsa (2*50 T/Kit) (Mindray) , Tpsa Calibrator 3*2Ml Mindrey , Tracheostomy Tubes - Jacksons , Size 28 (Mettalic) , Tracheostomy Tubes - Jacksons , Size 30 (Mettalic) , Tracheostomy Tubes - Jacksons , Size 32 (Mettalic) , Triglyceride Kit 5*20Ml (Erba) , Triglyceride Kit 5*6.5Ml (Erba) , Triple Sugar Iron Test (Tsi) (Himedia) 100Gm , Triple Sugar Iron Test (Tsi) (Himedia) 200Gm , Triple Sugar Iron Test (Tsi) (Himedia) 500Gm , Trop I Kit (Ctk) , Trop I Kit (Oscar) , Trop I Kit (Tulip) , Trop I Kit For Erba Em-200/Em-360 (Medsource Ozone) , Trop I Kit For Erba Em-200/Em-360 (Erba) , Trop T Kit For Erba Em-200/Em-360 (Medsource Ozone) , Trop T Kit For Erba Em-200/Em-360 (Erba) , Tropinin 1 (Erba) , Tropinin 1 (Tulip) , Troponin I (2*100 T/Kit) (Mindray) , Troponin I (2*50 T/Kit) (Mindray) , Troponin I Calibrator 3*2Ml Mindrey , Tsh (2*100 T/Kit) (Mindray) , Tsh (2*50 T/Kit) (Mindray) , Tsh Calibrator 3*2Ml Mindray , Tumor Marker Multi Control (H)3*5Ml Mindrey , Tumor Marker Multi Control (H)6*5Ml Mindrey , Tumor Marker Multi Control (L)3*5Ml Mindrey , Tumor Marker Multi Control (L)6*5Ml Mindrey , Typhidot Rapid Test , Uibc Kit For Erba Em-360/Em-200 , Ultrasound Gel 1000 Ml , Ultrasound Gel 250 Ml , Urease Medium (Himedia) 100Gm , Urease Medium (Himedia) 200Gm , Urease Medium (Himedia) 500Gm , Uric Acid Kit 5 X 50Ml (Erba) , Uric Acid Kit 5 X 50Ml (J. Mitra) , Urine Containers With Sticker (50Ml Capacity) , Urine Containers With Sticker 30Ml , Urine Droppers 5 Ml , Urine Screening Through Dry Chemistry Rapid Testing Kit/Strips For Multiple Drug Uses:- 1. Morphine/ Opiates 2. Buprenorphine 3. Tramadol 4. D. Propoxyphene 5. Benzodiazepines Test Kit , Urinorm Controls (High, Low, Normal) For Erba Laura Urine Analyzer , Uristix (10 Parameter) , Uristix (10 Parameter) (J.Mitra) , Uristix (10 Parameter) (Oscar) , Uristix (10 Parameter) Erba (Dekha Phan Laura) , Uristix For Albumin And Sugar Test , Uristix For Albumin And Sugar Test (J.Mitra) , Uristix For Albumin And Sugar Test(Oscar) , Vaccuatiner Racks For 100 Vials , Vaccuatiner Racks For 25 Vials , Vaccutainer Gel (Yellow Cap) , Vaccutainer Needle , Vaccutainer Needle Holder , Vaccutainer Sample Tubes (Vaccum Based) Blue Cap, 1.8 Ml , Vaccutainer Sample Tubes (Vaccum Based) Blue Cap, 2.7 Ml , Vaccutainer Sample Tubes (Vaccum Based) Purple Cap, 0.5Ml, K2 Edta , Vaccutainer Sample Tubes (Vaccum Based) Purple Cap, 1.0Ml, K2 Edta , Vaccutainer Sample Tubes (Vaccum Based) Red Cap, 0.5Ml , Vaccutainer Sample Tubes (Vaccum Based) Red Cap, 1.0Ml , Vaccutainer Sodium Fluoride Sample Tubes (Vaccum Based) Grey Cap, 2.0 Ml , Vaccutainers Edta 4Ml (Non -Vaccum) Purple Cap, K3 Edta , Vaccutainers Edta 4Ml (Vaccum Tubes) Purple Cap, K3 Edta , Vaccutainers Edta 6Ml (Vaccum Tubes) Bd , Vaccutainers Edta 4Ml (Non -Vaccum) Purple Cap, K2 Edta , Vaccutainers Edta 4Ml (Vaccum Tubes) Purple Cap, K2 Edta , Vaccutainers Red Top 4Ml ( Vaccum Clot Tube) , Vaccutainers Red Top 4Ml (Non - Vaccum Clot Tube) , Vaccutainers Red Top 6Ml (Vaccum Clot Tube) Bd , Vaccutainers Sodium Citrate (Vaccum Tubes, ) (For Esr 1.6 Ml)( Black Top) , Vaccutainers Sodium Citrate 3.2% Blue Top (Non - Vaccum) , Vaccutainers Sodium Citrate 3.2% Blue Top(Vaccum Tubes) , Vaccutainers Sodium Citrate 3.8% For Esr (Black Top) Tube (Vaccume) , Vaccutainers Sodium Citrate 3.8% For Esr (Black Top) Tube (Non - Vaccume) , Vaccutainers Sodium Citrate 3.8% For Esr (Black Top) Tube (Vaccume) 1.28Ml*8X120Mm , Vb12 (2*100 T/Kit) (Mindray) , Vb12 (2*50 T/Kit) (Mindray) , Vb12 Calibrator 3*2Ml Mindrey , Vdrl (Syphilis Kit Elisa 96 Test) , Vdrl (Syphilis Kit Elisa 96 Test) (Athenese-Dx) , Vdrl (Syphilis Kit Elisa 96 Test) (Erba) , Vdrl (Syphilis Kit Elisa 96 Test) (J. Mitra) , Vdrl (Syphilis Kit Elisa 96 Test) (Oscar) , Vdrl (Syphilis Kit Elisa 96 Test) (Tulip) , Vdrl Card (Bioline) , Vdrl Card (Erba) , Vdrl Card (J.Mitra) , Vdrl Card (Meril) , Vdrl Card (Oscar) , Vdrl Card (Ozone) , Vdrl Card (Tulip) , Vd-T (1*100 T/Kit) (Mindray) , Vd-T (1*50 T/Kit) (Mindray) , Vd-T Calibrator 3*2Ml Mindrey , Vtm Kit With Oral And Nasal Swab Pair , Vtm Vial Rack , Wash Bottles , Wash Buffer 10 L/Tank Mindray , Washing Bursh Test Tube , Waste Tank Transparent Plastic For Liquid Waste 20 Ltr , Waste Tank Transparent Plastic For Liquid Waste 40 Ltr , Water Test Kit For Faecial Condemination , Wax Ribbon 100Mm X 100Metres Ink Out , Wbc Diluting Fluid (Nice) 100 Ml , Weekly Maintenace Tray For E-411 (Roche) , Whatman Filter Paper 110Mm , Whatman Filter Paper 125Mm , Whatman Filter Paper 55Mm , Whatman Filter Paper 90Mm , Widal Kit 2+2 X 5Ml (Arkery) , Widal Kit 2+2 X 5Ml (Oscar) , Widal Kit 2+2 X 5Ml (Tulip) , Widal Kit 5X4 Ml (Arkery) , Widal Kit 5X4 Ml (J. Mitra) , Widal Kit 5X4 Ml (Oscar) , Widal Kit 5X4 Ml (Tulip) , Widal Tube Agglutination Test Kit , Xylene 2500Ml (Nice) , Zinc Oxide Powder (Dentsply/Dpi/Gc/Mani) , Zinc Phosphate Cement , Powder And Liquid 100 Gm(Harward) (Dentsply/Dpi/Gc/Mani) , Air Mattress , Adenoid Curvatte With Guard , Adult Weighing Scale Digital With One Year Replacement Warranty , Adult Weighing Scale Digital With One Year Replacement Warranty (Accusure) , Agfa Complete X Ray Cassette With I.P Size 10X12 , Agfa Complete X Ray Cassette With I.P Size 14X17 , Agfa X-Ray Cassette Without I.P 10X12 , Agfa X-Ray Cassette Without I.P 14X17 , Allis Forcep 8 (Tissue Forcep) Ss304 , Allis Forceps 6 (Ss/304 Min.) , Amalgam Carver (Ss/304 Min.) , Amalgam Condensor (Ss/304 Min.) , Ankle Exerciser , Artery Forceps Straight 6 (Ss/304 Min.) , Artery Forceps Straight 9 (Ss/304 Min.) , Aural Spaculam , Aurolab Aqueous Drainage Implant , Autoclave Heating Element Size 1.5 (6Kw) , Autoclave Heating Element Size 2.0 (9Kw) , Autoclave 1000 Voltage 10 Litre , Autoclave 1000 Voltage 12 Litre , Autoclave 1000 Voltage 15 Litre , Autoclave Drum Large (Steel Grade 304) (11*9) , Autoclave Drum Medium (Steel Grade 304) (10*12) , Autoclave Drum Medium (Steel Grade 304) (12*15) , Autoclave Drum Small (Steel Grade 304) (8*10) , Autoclave Rubber Gasket , Autoclave Tape 19Mm X 50Mtr. , Babcock (8 Long)(Ss/304 Min.) , Baby Weighing Scale Digital With One Year Replacement Warranty , Bath Soap 75Gm , Bed Sheet Size-150 X 240 Cm, Color (Violet,Indigo, Blue,Green,Yellow,Orange,Peach) , Bed Side Pulley , Bench Top Centrifuge (Table Top Centrifuge) Machine , Big Bowl / Tray ( For Placenta)(Ss) , Bio Medical Dust Bin 10 Ltr Plastic (First) Body (Blue Black Yellow) , Bio Medical Dust Bin 10 Ltr Plastic (First) Body (Blue Black Yellow) Foot Operated , Bio Medical Dust Bin 20 Ltr Plastic (First) Body (Blue Black Yellow) , Bio Medical Dust Bin 20 Ltr Plastic (First) Body (Blue Black Yellow) Foot Operated , Biopsy Punch (Set) (Ss, Cylindrical With 0.5,0.8 & 1Cm)(Ss/304 Min.) , Blade Holding Forcep, Ss 304 , Blakesley Strough Cut Forceps Straight Angled (Ss/304 Min.) , Blood Bag Weighing Scale Manual With One Year Replacement Warranty , Blood Collection Moniter With Blood Bag Scale With 2 Year Warranty And 2 Year Cmc 5% On Basic Construction , Blood Tube Roller Mixer With One Year Replacement Warranty , Boyle Devis Mouth Gag With Different Size Blade , Bone Chisel Complete Set , Bone Chisel Complete Set (Nebula) , Bone Chisel Complete Set (Genius) , Bone Chisel Complete Set (Sythes / Ao) , Pelvic Clamp Compelete Set , Pelvic Clamp Compelete Set (Nebula) , Pelvic Clamp Compelete Set (Genius) , Pelvic Clamp Compelete Set (Sythes / Ao) , Patella Bone Holding Clamp , Patella Bone Holding Clamp (Nebula) , Patella Bone Holding Clamp (Genius) , Patella Bone Holding Clamp (Sythes/Ao) , Plier Compelete Set , Plier Compelete Set (Nebula) , Plier Compelete Set (Genius) , Plier Compelete Set (Sythes/Ao) , Bone Lever (Medium) , Bone Lever (Medium) (Nebula) , Bone Lever (Medium) (Genius) , Bone Lever (Medium) (Sythes/Ao) , Bone Lever (Large) , Bone Lever (Large)(Nebula) , Bone Lever (Large) (Genius) , Bone Lever (Large) (Sythes/Ao) , Bone Lever (Cobra) , Bone Lever (Cobra)(Nebula) , Bone Lever (Cobra) (Genius) , Bone Lever (Cobra) (Sythes/Ao) , Reduction Clamp Compelete Set , Reduction Clamp Compelete Set (Nebula) , Reduction Clamp Compelete Set (Genius) , Reduction Clamp Compelete Set (Sythes/Ao) , Bone Nibbler Compelete Set , Bone Nibbler Compelete Set (Nebula) , Bone Nibbler Compelete Set (Genius) , Bone Nibbler Compelete Set (Sythes/Ao) , Bone Cutter , Bone Cutter (Nebula) , Bone Cutter (Genius) , Bone Cutter (Sythes/Ao) , Tissue Protecting Sleeve , Tissue Protecting Sleeve(Nebula) , Tissue Protecting Sleeve (Genius) , Tissue Protecting Sleeve (Sythes/Ao) , Curette Compelete Set , Curette Compelete Set (Nebula) , Curette Compelete Set (Genius) , Curette Compelete Set (Sythes/Ao) , Bone Spike Compelete Set , Bone Spike Compelete Set (Nebula) , Bone Spike Compelete Set (Genius) , Bone Spike Compelete Set (Sythes/Ao) , Plate Holder Compelete Set , Plate Holder Compelete Set (Nebula) , Plate Holder Compelete Set (Genius) , Plate Holder Compelete Set (Sythes/Ao) , T Handle + Key , T Handle + Key(Nebula) , T Handle + Key (Genius) , T Handle + Key (Sythes/Ao) , Bone Hook , Bone Hook(Nebula) , Bone Hook (Genius) , Bone Hook (Sythes/Ao) , Periosteal Elevator Straight Compelete Set , Periosteal Elevator Straight Compelete Set (Nebula) , Periosteal Elevator Straight Compelete Set (Genius) , Periosteal Elevator Straight Compelete Set (Sythes/Ao) , Periosteal Elevator Curved Compelete Set , Periosteal Elevator Curved Compelete Set (Nebula) , Periosteal Elevator Curved Compelete Set (Genius) , Periosteal Elevator Curved Compelete Set (Sythes/Ao) , Bone Saw Compelete Set , Bone Saw Compelete Set (Nebula) , Bone Saw Compelete Set (Genius) , Bone Saw Compelete Set (Sythes/Ao) , Extraction Bolt , Extraction Bolt(Nebula) , Extraction Bolt (Genius) , Extraction Bolt (Sythes/ Ao) , Gigly Saw Hook , Gigly Saw Hook(Nebula) , Gigly Saw Hook (Genius) , Gigly Saw Hook (Sythes/ Ao) , Bone Rasp/ File , Bone Rasp/ File(Nebula) , Bone Rasp/File (Genius) , Bone Rasp/File (Sythes/ Ao) , Broad Osteotome , Broad Osteotome(Nebula) , Broad Osteotome (Genius) , Broad Osteotome (Sythes/Ao) , Charnley Retractor , Charnley Retractor(Nebula) , Charnley Retractor (Genius) , Charnley Retractor (Sythes/Ao) , Lamina Spreader , Lamina Spreader(Nebula) , Lamina Spreader (Genius) , Lamina Spreader (Sythes/Ao) , Universal Drill Sleeve , Universal Drill Sleeve(Nebula) , Universal Drill Sleeve (Genius) , Universal Drill Sleeve (Sythes/Ao) , Surgical Gown Disposable , Surgical Gown Disposable (Surgiwear) , Surgical Gown Disposable (Bio Flex) , Surgiwear C Arm Cover , Half Gown , Half Gown (Surgiwear) , Polydrape , Polydrape (Surgiwear) , Ioban Large , Ioban Large (Surgiwear) , Hip U Drape , Surgiwear Hip U Drape , Tkr Knee Drape , Tkr Knee Drape (Surgiwear) , Primapore 10 X 25 Size , Pulse Lavage , Tricofix Stockinnette , Stapler Remover Complete Set , Stapler Remover Complete Set (Nebula) , Stapler Remover Complete Set (Genius) , Stapler Remover Complete Set (Sythes/Ao) , Cautery Lead , Normal Saline 3 Ltr. , Cling Roll , Bone Holding Forcep Complete Set , Bone Holding Forcep Complete Set (Nebula) , Bone Holding Forcep Complete Set (Genius) , Bone Holding Forcep Complete Set (Sythes/Ao) , Plate Holding Forcep Complete Set , Plate Holding Forcep Complete Set (Nebula) , Plate Holding Forcep Complete Set (Genius) , Plate Holding Forcep Complete Set (Sythes/Ao) , Reduction Forcep Complete Set , Reduction Forcep Complete Set (Nebula) , Reduction Forcep Complete Set (Genius) , Reduction Forcep Complete Set (Sythes/Ao) , Bone Cutting Forcep Complete Set , Bone Cutting Forcep Complete Set (Nebula) , Bone Cutting Forcep Complete Set (Genius) , Bone Cutting Forcep Complete Set (Sythes/Ao) , Osteotome Complete Set , Osteotome Complete Set (Nebula) , Osteotome Complete Set (Genius) , Osteotome Complete Set (Sythes/Ao) , Self Retaining Retractor Complete Set , Self Retaining Retractor Complete Set (Nebula) , Self Retaining Retractor Complete Set (Genius) , Self Retaining Retractor Complete Set (Sythes/Ao) , Periosteal Elevator Complete Set , Periosteal Elevator Complete Set (Nebula) , Periosteal Elevator Complete Set (Genius) , Periosteal Elevator Complete Set (Sythes/Ao) , Bone Lever Complete Set , Bone Lever Complete Set (Nebula) , Bone Lever Complete Set (Genius) , Bone Lever Complete Set (Sythes/Ao) , Bone Currette Complete Set , Bone Currette Complete Set (Nebula) , Bone Currette Complete Set (Genius) , Bone Currette Complete Set (Sythes/Ao) , Bone Hook Complete Set , Bone Hook Complete Set (Nebula) , Bone Hook Complete Set (Genius) , Bone Hook Complete Set (Sythes/Ao) , Hammer Complete Set , Hammer Complete Set (Nebula) , Hammer Complete Set (Genius) , Hammer Complete Set (Sythes/Ao) , Plate Bending Press , Plate Bending Press (Nebula) , Plate Bending Press (Genius) , Plate Bending Press (Sythes/Ao) , Depthgauge Complete Set , Depthgauge Complete Set (Nebula) , Depthgauge Complete Set (Genius) , Depthgauge Complete Set (Sythes/Ao) , Wire Cutter , Wire Cutter (Nebula) , Wire Cutter (Genius) , Wire Cutter (Sythes/Ao) , Tissue Protection Sleeve , Tissue Protection Sleeve (Nebula) , Tissue Protection Sleeve (Genius) , Tissue Protection Sleeve (Sythes/Ao) , Rasp Complete Set , Rasp Complete Set(Nebula) , Rasp Complete Set (Genius) , Rasp Complete Set (Sythes/Ao) , Angle Blade Plate , Endo Button , Shoulder Hemiarthroplasty , Vicryl Cutting Needle (Double) , Ethibond No. 5 , Portabel Ot Light Led Based One Lakh Lux , Bohlr Broun Frame , Clutch Wire , Clutch Wire (Nebula) , Clutch Wire (Genius) , Clutch Wire(Sythes/Ao) , Flexible Power Reamer Completet Set , Flexible Power Reamer Completet Set (Nebula) , Flexible Power Reamer Completet Set (Genius) , Flexible Power Reamer Completet Set(Sythes/Ao) , Beaded Guide Wire , Beaded Guide Wire (Nebula) , Beaded Guide Wire (Genius) , Beaded Guide Wire (Sythes/Ao) , Bone & Plate Hoding Forcep For Mini Plate , Bone & Plate Hoding Forcep For Mini Plate (Nebula) , Bone & Plate Hoding Forcep For Mini Plate (Genius) , Bone & Plate Hoding Forcep For Mini Plate (Sythes/Ao) , Fergusson (Fibula) Bone Holding Forcep , Fergusson (Fibula) Bone Holding Forcep (Nebula) , Fergusson (Fibula) Bone Holding Forcep (Genius) , Fergusson (Fibula) Bone Holding Forcep(Sythes/Ao) , Lowman Bone Clamp , Lowman Bone Clamp (Nebula) , Lowman Bone Clamp (Genius) , Lowman Bone Clamp (Sythes/Ao) , Wire Tensioner , Wire Tensioner (Nebula) , Wire Tensioner (Genius) , Wire Tensioner (Sythes/Ao) , Wire Passer , Wire Passer (Nebula) , Wire Passer (Genius) , Wire Passer(Sythes/Ao) , Charnley Retractor , Charnley Retractor (Nebula) , Charnley Retractor (Genius) , Charnley Retractor(Sythes/Ao) , Bone Curette , Bone Curette (Nebula) , Bone Curette (Genius) , Bone Curette (Sythes/Ao) , Czerney Retractor , Czerney Retractor (Nebula) , Czerney Retractor (Genius) , Czerney Retractor (Sythes/Ao) , Bosch Drill Machine , Colinear Clamp , Colinear Clamp (Nebula) , Colinear Clamp (Genius) , Colinear Clamp(Sythes/Ao) , Broken Screw Removal Set , Broken Screw Removal Set (Nebula) , Broken Screw Removal Set (Genius) , Broken Screw Removal Set(Sythes/Ao) , Spanner (Complete Set) , Spanner (Complete Set) (Nebula) , Spanner (Complete Set) (Genius) , Spanner (Complete Set) (Sythes/Ao) , Femur Entry Reamer , Femur Entry Reamer (Nebula) , Femur Entry Reamer (Genius) , Femur Entry Reamer(Sythes/Ao) , Graft Awl , Graft Awl (Nebula) , Graft Awl (Genius) , Graft Awl(Sythes/Ao) , K Wire Cutter , K Wire Cutter (Nebula) , K Wire Cutter (Genius) , K Wire Cutter(Sythes/Ao) , Ankle Spreader , Ankle Spreader (Nebula) , Ankle Spreader (Genius) , Ankle Spreader(Sythes/Ao) , Hip Cement Removal Set , Hip Cement Removal Set (Nebula) , Hip Cement Removal Set (Genius) , Hip Cement Removal Set(Sythes/Ao) , Corticotome Osteotomes Fiber Handle , Corticotome Osteotomes Fiber Handle (Nebula) , Corticotome Osteotomes Fiber Handle (Genius) , Corticotome Osteotomes Fiber Handle(Sythes/Ao) , Bone Gouge Curved , Bone Gouge Curved (Nebula) , Bone Gouge Curved (Genius) , Bone Gouge Curved(Sythes/Ao) , Drill Bits Complete Set , Drill Bits Complete Set (Nebula) , Drill Bits Complete Set (Genius) , Drill Bits Complete Set(Sythes/Ao) , Stratafix , Bp Apparatus Clock Model (Diamond) , Bp Apparatus Clock Model (Pagoda) , Bp Apparatus Clock Model (Novaphone) , Bp Apparatus Digital Led/Lcd Type (Diamond) , Bp Apparatus Digital Led/Lcd Type (Pagoda) , Bp Apparatus Digital Led/Lcd Type (Novaphone) , Bp Apparatus Digital Led/Lcd Type (Accusure) , Bp Apparatus Electronic With Charger (Omron) , Bp Handle - For Blade , Brode Locking Plate , Broomstick Long Per Kg , Bulb For Bp Appartus , Cancellous Full Thread 6.5 , Cannulatedcanvellous Screw 4Mm , Capsular Tension Ring (Morcher 14) , Capsulorhexis Ultrafine Forceps , Castroviejo Caliper Graduated , Centrifuge Machine Digital Without Carbon With 2 Year Warranty And 2 Year Cmc 5% On Basic Construction , Cheatle Forceps-Large (Ss/304 Min.) , Cheatle Forceps-Small(Ss/304 Min.) , Cheek Retractor - Adult Type(Ss/304 Min.) , Chip Bowler , Chiropractic Table , Circular Knife(Ss/304 Min.) , Clavical Locking Plate , Colour Vision Book For Eye Opd , Continous Passive Motion Unit , Contrast Bath Unit , Corneoscleral Scissor 4.5 Inch (Ss/304 Min.) , Corocodile Forcep 14 Cm (Ss/304 Min.) , Cortical Screw 3.5 , Cortical Screw 4.5 , Cpm (Continous Passive Movement) For Elbow Joint With 3 Year Warranty , Cpm (Continous Passive Movement) For Knee Joint With 3 Year Warranty , Cricoid Hook Retractor , Cross Bar/Winters Elevator , Cryer Elevator(Left) , Cryer Elevator(Right) , Cuff Bladder For Bp Appartus , Cuff Cloth For Bp Appartus , Cuff, Bladder Complete Set Compatible With Omron Electronic Bp Appartus , Curette With Sharp Ends 10Mm Wide (Ss/304 Min.) , Curette With Sharp Ends 5Mmwide (Ss/304 Min.) , Curreter 5Mm Wide (Ss 304) , Curved Artery Forceps 6 Ss (Ss/304 Min.) , Curved Artery Forceps 9/10 (Ss/304 Min.) , Curved Spatula (Ss/304 Min.) , Cusco Speculum (Medium) Ss 304 (Tuft) , Cutting Scissor (Blunt End ) Ss304- 8 (Tuft) , Dappen Dish , Delivery Kit (All Instruments) Ss 412 , Depth Gauze , Dhs/Dcp Plate , Di-Electric Tube Sealer With 2 Year Warranty And 2 Year Cmc 5% On Basic Construction , Digital Balance Board With Tab , Digital Thermometer Six Month Replacement Warranty (Dr Morepen/Saracare/Bpl) , Digital Timer For Laboratory , Digital Weighing Scale (Measurement In Milligram And Gram) , Digital Weighing Scale (Measurement In Milligram To 10 Kg) , Disposable Plastic Bed Pan , Disposable Plastic Urine Pot , Dissecting Forceps (Ss/304 Min.) , Distal End Radius T Plate And T , Distal Femur Locking Plate , Distal Fibia Locking Plate , Distal Humerous D/L With Support Locking Plate , Distal Humerous Metaphyseal Locking Plate , Distant Vision Chart For Eye Opd , Dj Stunt , Dj Stunt No 5/26 Both End Open , Dj Stunt No 6/26 Both End Open , Dj Stunt No. 6 French End Closed , Dj Stunt No.5.5 , Donor Couch , Doyens Retractor Ss304 , Drill Bit 2.5 , Drill Bit 2.7 , Drill Bit 2.8 , Drill Bit 3.2 , Drill Bit 4.0 , Drill Bit 4.3 , Dumble Iron With Cart , Ear Parking Forceps , Ecg Machine 12 Channel Lead -Patient Cable , Ecg Machine 12 Channel With 2 Year Warranty And 2 Year Cmc Rate Freezed On 5% Of Basic Cost , Ecg Machine Chest Electrode (Bulb) , Ecg Machine Chest Electrode (Metal Clamp) , Erba Transponder , Ec Cartridge 250 Test , Ec Cartridge 500 Test , Ec Cartridge 1000 Test , Ec Cartridge 2000 Test , Electrical Muscle Stimulator Diagnostic & Therapeutic , Enlarger 3.2 (Antiglare) , Enlarger 5.2 (Antiglare) , Enlarger 5.5 (Antiglare) , Episiotomy Scissor 6 Ss 304 , Exercise Sponge Ball , Expert Tibia Nail , External Fixator Set In Schanl Pin , Fetal Doppler Portable With Rechargable Battery And Adapter/Charger And With One Year Replacement Warranty (Bpl Company) , Femoral Distractor , Fibula Locking Plate , Finger Ladder Bar , Fire Extinguisher (Abc) 5 Kg Isi Mark , Fire Extinguisher (Co2) 4.5 Kg Isi Mark , Floor Duster 1X1Mt Superior Quality , Focus Lamp , Fogger Machine , Foot Rest (Ss) , Fumigation Chamber 3 Tray For Instruments , Fumigator Machine For Operation Theatre (Ss) , Genio Meter , Gigli Saw , Gonadal Shield , Graft Pressor Forceps , Granulation (Cup) Ear Forceps , Guide Wire Teflon Coated V Straight Tip , Gulde Wire For Interlocking/Dhs , Haemostatic Tournique , Hammer Ss Handle , Hand Duster 22 X 22Cm , Hard Shell Plates , Heating Element For Sterilizer , Heavy Periosteal Elevator , Hip Circumductor , Histrectomy Clamps 8 Long Box Joint, With Cross Serration Of Jaws With Good Strong Grip , Hohmann Retractor Small , Hohmann Retractor Medium , Hohmann Retractor Large , Hospital Bed Iron (Semi Fowler) , Hub Cutter (Electrical) With Six Month Replacement Warranty , Hub Cutter (Mannual) , Hub Cutter (Mannual) With Ss Stand 1.5 Ltr. , Hub Cutter (Mannual) With Ss Stand 2 Ltr. , Hub Cutter (Mannual) With Ss Stand 3 Ltr. , Hub Cutter (Mannual) With Ss Stand 5 Ltr. , Hydrocolatral Pad Single Pc , Hypophanyngoscope , Instrument Tray With Lid(12X 10) (Steel Grade 304) , Instrument Tray With Lid(12X 18) (Steel Grade 304) , Instrument Tray With Lid(12X 8) (Steel Grade 304) , Instrument Trolly With Wheel (Ss304) , Inter Francial Therapy , Interlocking Bolt 3.5 , Interlocking Bolt 4.9 , Iris Hooks , Iso-Kinetic Exercise Equipment For Knee, Elbow And All Parts Of Body , Iv Stand Ss 304 With Wheel , Jumbo Cutter , K Wire Sterile/ Non Sterile , Kellys Punch , Kidney Tray Small (Steel Grade 304) , Kidney Tray (Big) Ss304 , Kidney Tray (Small) Ss304 , Kidney Tray Big (Steel Grade 304) , Knee Exerciser , Kocher Forcep Ss 304 8 , Kurta, Petticoat Sets Large Size , Green Strip , Labour Table Ss , Langenbeck Retractor Right Angle Ss 304 , Laryngoscope Blade No. 00 (Prenatal) , Laryngoscope Direct Led Adult , Laryngoscope Direct Led Pead. , Laser Unit/ Electro Therapy , Lateral Tibia Locking Plate , Leg Hip Screw , Legaclip Size Lt 300 , Legaclip Size Lt 400 , Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed , Locking Cancellous 3.5 , Locking Cancellous 6.5 (16Mm Thread) , Locking Cancellous 6.5 (32Mm Thread) , Locking Plate , Locking Screw 2.7 , Locking Screw 5Mm , Long Pfn , Magnetic Peg Board , Malicoat Catheter 4 Wings , Malleus Head Nipper , Mattress Hospital With Rexin Cover 72*36*4 Inch 40 Density 3 Year Warranty , Mayos Scissors 8 Long But Blades Are Only With Sharp Edges Curved, With Tip Only 2Mm Broad ( Ss/304 Min.) , Mayos Scissors Straight 6 Ss (Ss/304 Min.) , Mectronic Class 4 Laser Upto 20W With Dual Wave Length , Micro Ear Currette (Ss/304 Min.) , Micro Motor Unit For Drilling (Hand Piece, Foot Switch, Motor) , Microscope (Binocular) With Led (Alco) With 3 Year Warranty , Microscope (Binocular) With Led (Labomed) With 3 Year Warranty , Microscope (Binocular) With Led (Olympus) With 3 Year Warranty , Microwave Diathermy , Mini Cryotherapy Unit For Physiotherapy , Mini-Shaker For Immunology , Multi Para Monitor Spo2 Probe (Make Contac) , Mini Plate With Screw Box , Multipara Monitor (3 Parameter) With 2 Year Warranty And 2 Year Cmc Freezed On 5% Of Basic Cost , Multipara Monitor (5 Parameter) With 2 Year Warranty And 2 Year Cmc Freezed On 5% Of Basic Cost , Muscle Strength Tester , Narrow Loking Plate , Near Vision Chart For Eye Opd , Nebulizers With Six Month Replacement Warranty , Needle Holder 10 With Tungsten Carbide Blades Ss , Needle Holder 8 With Tungsten Carbide Blades Ss , Needle Holder Hegars Pattern 10 Tungsten Carbide Ss 304 , Non Toothed Dissecting Forceps ( 9 Long) , Nose Plier , Nsv Set , O T Light Bulb (Mirchi Type) , Almirah Office Size Height - 78 X Width - 36 X Depth - 19 Manufactured From 20 Guage For Body And 18 Guage For Doors Having 04 Selves Making 5 Compartments Rate Per Kg , Oertli Vitreous Cutter , Oesophagoscope Adult , Oesophagoscope Pead. , Oil Filled Room Heater 12 Fin One Year Replacement Warranty , Ophthalmic Trial Frame , Ophthalmic Trial Lens Set With Box , Ophthalmoscope Head , Opthalmoscope , Oxygen Cylinder B Tybe With Isi Standard Is7285 And Certified By Bisand Also Approved By Ccoe And With One Year Replacement Warranty And (Medicinal Gas Filling With Transport Charges) , Oxygen Cylinder D Type With Isi Standard Is7285 And Certified By Bisand Also Approved By Ccoe With One Year Replacement Warranty And (Medicinal Gas Filling With Transport Charges) , Oxygen Flowmeter With Humidifier Bottle , Patella Double Prong With Bolt Tip Curved , Pen Nail , Pen Screw 6Mm , Pen Screw 8Mm , Periosteal Elevator Ss , Periosteal Elevator Round Shape , Periosteal Elevator Square Shape , Pfn Drill Bit , Pfn Guide Wire , Phaco Chopper Sharp , Phaco Slive , Phaco Speculum Self Retaining , Phaco Tubing , Phenyl Liquid For Floor Cleaning 5Ltr. , Philos Locking Plate , Phototherapy Machine Led With 2 Year Warranty And 2 Year Cmc Freezed Rate Upto 5% Of Basic Cost , Planter Pressure System , Plaster Bowl , Plaster Knife , Plaster Spatula , Plate Bending Press , Palate & Bone Holding Forcep With Tap & Drill Sleeve , Polishing Brush , Polishing Cup , Portable Autoclave With One Year Replacement Warranty , Postural Training Mirror , Ppiucd Kit (Copper-T Set) , Probe Double Ended (Ss) , Probe For Ctg Machine (Life Plus) , Probe Single Ended (Ss) , Proximal Femoral Locking Plate , Pulse Electro Magnetic Field (Pemf) , Pulse Oxymeter (Finger Tip) With Isi Marked And One Year Replacement Warranty , Quardicep Board , Quardicep Table , Radiant Warmer With 2 Year Warranty And 2 Year Cmc Rate Freezed On 5% Of Basic Cost , Recon Plate , Refractometer , Refrigerator Tempemprature Graph (Round Figure) (Small Size) , Refrigerator Temperature Graph (Round Figure) (Big Size) , Rubber Slipper (Different Sizes) For O.T. , Scissors 9 (Long Straight Blade) (Ss/304 Min.) , Scleral Loop Depresser For Rop Screening , Sealer, Stripper And Cutter For Blood Bag Tubing , Self Retaining Long Bladed Nasal Spaculum (Killian) , Serafine Bulldog Clamp , Set Of Knifes & Forceps For Cutting Tissues (All Sizes) , Self Retaining Forceps , Sharp Bio Waste Container With Lid 1Ltr (White/Blue) , Sharp Bio Waste Container With Lid 5Ltr (White/Blue) , Shaving Blade , Shock Wave Diathermy , Shock Wave With Dual Probe , Short Pfn , Short Wave Diathermy 400 Watt With 3 Year Warranty , Shoulder Cum Elbow Cycle , Shoulder Pulley (Wall Mounted) , Shoulder Wheel (Wall Mounting) , Sickle Knife (Ss/304 Min.) , Sim Speculum (Long And Broad) Ss304 , Simple Bipolar , Sims Speculum ( Narrow) (Ss/304 Min.) , Skeletal Traction , Skin Grafting Handle , Skin Grafting Blade , Skin Hook Retractor , Skin Stapler Standard ( Single Unit) , Skin Traction Set Small Size , Small Bowl 50 Ml Capacity Ss , Small Locking Plate , Spine Analysis System Portable , Sponge Ball (Rubber) , Sponge Holding Forcep 9/10 Ss 304 , Spunch Holder (Box Joint 8) , Square Abdominal Retractor With Frame And Two Sets Of Retractor Blades Of Four Each One Set For Thin And Other Obese Patient , Staining Trough , Stainless Steel Probe , Stalion 3 & 2 Packed , Steamer , Steel Embedding Mould Large , Steel Embedding Mould Medium , Stemin Pin/Sterllie Pin Sterille , Stenlizing Case With Matts , Sterile Blopolar , Sterlizer 12 Inch (Ss304) , Sterlizer 16 Inch (Ss304) , Sterlizer 8 Inch (Ss304) , Stethoscope (Adult) (Diamond/Pagoda/Novaphone) , Stethoscope (Ped) (Diamond/Pagoda/Novaphone) , Stethoscope Neonate (Diamond/Pagoda/Novaphone) , Suction Elevator , Suction Machine (Foot Operated) , Suction Machine Electrical With One Year Replacement Warranty , Suction Jar Plastic With Lead 1500Ml , Supinator & Pronator Unit (Zig-Zag Type) , Suture Tying Forceps , T Handle With Chuck , Temporal Nasal Speculum , Tens Nail , Thera Bands With Different Power Grades , Thermometer For Refrigerator (Digital) , Thermometer For Room Temperature (Digital) , Thick Allis , Thudicum Nasal Speculum , Tilley Aurap Forcep , Tibia Reduction Clamp , Tip Of Applanation Tonometer , Tonsellar Dirsector , Tonsillar Shair , Tooth Forcep 6 (Ss304) , Toothed Dissecting Forceps (7 Long - Teeth 4X5) , Towel Clips Box Joint 4 , Tracheal Dilator , Traction Table Four Fold , Transcuteneous Electrical Nerve Stumination/ Tens With 3 Year Warranty , Trimming Stones (Assorted) , Tubular Plate 1/3 , Turp Loop , Tweezer (Ss) , Ultra Sonic Therapy Dual Frequency Unit With 3 Year Warranty , Universal Femur Nail , Universal Tibia Nail , Urine Ketone Test Strip , Uterine Sound , Vaginal Retractor (With Flat Blade 1.5 Broad And 1.5 Long) , Vaccum Cup / Ventose Cup For Delivery , Vasculum Forcep , Vdrl Shaker (Rotator) , Vein Scanner/Finder Paed. , Ventilator Circuit , Vertical Autoclave (Size 12*20) And Ss304 With One Year Replacement Warranty , Vertical Autoclave Tripple Valve (Size 16*24) With 2 Year Warranty And 2 Year Cmc Rate Freezed On 5 % Of Basic Cost , Wall Ladder , Water Bath (Serological) , Wax Knife , Wax Spatula , Weight Caff , Wheelchair Folding Type , Wire Loop , Wire Passer , Wire Speculum (Screw) , Wire Speculum Plain , Wire Vectis For Eye , Wrist Circumductor , X Ray View Box (Regular Led Type ) 18 X 24 Inch
Contract Date: May 06, 2026 Contract Value : 1.62 Crore
Government Departments No of Bidders 10
6.
Educational and Research Institute #10625357 Price Bid
Supply Of Instruments / Equipments=1.00 Flow Meter 1.01 Size : 40- 100 Mm 1.02 Flow Range : 25- 250Ml / Mnt 1.03 Volume Per Revolution : 0.309L 1.04 Greatest Pressure : 2.5 Mpa 1.05 Accuracy : ±0.2% 1.06 Repeatability : ≤0.05% 1.07 Standard Unit : Rise 2.00 Co2 Probe 2.01 Exact Application : Measurement Of Dissolved Co2 In Microalgae Culture 2.02 Measurement Range : 10 To 1000 Mbar Co2 2.03 Accuracy : ± ( 10 % Of The Reading + 10 Mbar ) 2.04 Operating Temperature :0 To 60 °C ( 32 To 140 °F ) 2.05 Mechanical Temperature Resistance : – 20 To 130°C ( – 4 To 266 °F ) 2.06 Operating Pressure : 0.2 To 2 Bar ( 3 To 30 Psia ) 2.07 Mechanical Pressure Resistance Max. : 3 Bar ( 42 Psia ) At 25 °C ( 77 °F ) 2.08 Response Time T90 : At 25 °C ( 77 °F ) < 120S 2.09 Steam Sterilizable And Autoclavable : Yes 2.10 Cable Connection : Ak 9 2.11 O2 Selective Membrane Material : Ptfe / Silicone 2.12 Shaft Diameter : 12 Mm 2.13 Available Lengths : 220- 320 Mm 2.14 Distance Between Sensor And Transmitter : 40Mm 2.15 Blind Transmitter : Ok 3.00 Palletizer Machine 3.01 Body Material : Hardened Mild Steel 3.02 Output Capacity : 20 To 50 Kg / Hr 3.03 Pallete Size Die : 8Mm To 10Mm 3.04 Motor Power Capacity : 3 To 5 Hp 3.05 Roller : 1 Set 3.06 Palletizer Mill Weight : 90 Kg 3.07 Palletizer Mill Size ( H X L X W ) : 36 X 48 X 24 3.08 Movement Of Palletizer Mill : Trolley On Wheels 3.09 Shape Of Hopper : Round 4.00 Shredder Machine 4.01 Cutting Mechanism : Twin Shaft 4.02 Shred Chamber ( Mm ) : 310×310 4.03 Shred Size ( Mm ) : 8×50-100 4.04 Shred Capacity : 200-300 Kg / Hr 4.05 Voltage : 415V 4.06 Power : 3 Hp 4.07 Hopper Volume ( Liters ) : 60 L 4.08 Waste Volume ( Liters ) : 180 L 4.09 Weight : 275 Kg 4.10 Running Cycle : Continuous 5.00 Soxhlet Appratus 5.01 Automatic Pc Compatible Solvent Extraction System ( Digital ) 5.02 • Fully Automatic Programmable Six Place Auto Sequencing Pc Compatible Solvent Extraction System 5.03 • Tft Graphic Touch Screen Display With Unique Wireless Mouse To Operate Directly Without Connecting To Pc. 5.04 • Icons To Represent Output Of Heating Process In Touch Screen Display 5.05 • Selectable Programs ( Customizable ) : Integrated Auto Sequencing Features With Intelligent Memory Programs Minimum 50 Programme With 10 Sequencing Steps With Inbuilt Datagger With User Id, Channel Name, Scan Rate, File Browse Feature To Download Stored Data With Inbuilt Software For Usable Csv And Excel Format 5.06 • Data Logger With Real Time Clock With Memory Stick For Data Storage With Separate Port In Mother Board Apart From Pc Port 5.07 • The Advanced Superior Pc Chart Software Performs Live Graphical Representation Of Time / Temperature Gradient On Touch Screen Display Directly. 5.08 • Temperature Range: 35°C ( Ambient ) To 300°C, Temperature Accuracy / Precision : + 0.5° C 5.09 • Temperature Controller Should Be Isolated Separately In A Control Tower To Protect Electronics From Solvent Area & Heat Zone For Safe Operation 5.10 • Measuring Range: 0.1 To 100% Fat / Oil 5.11 • Repeatability: + 1% Or Better 5.12 • Speed Of Extraction: 40 To 60 Minutes Depending On Application 5.13 • Auto Phase Change Of Extraction Includes Boiling, Condensation, Rinsing, Solvent Recovery & Predrying 5.14 • Inbuilt Airpump, Ss Manifold, Automatic Collection Of Recovered Solvent, Versatile Sizes Of Thimble ( Extra Thimble Should Be Provided ) 5.15 • Upgradeable Remote Control Module For Wireless Data Monitoring, Control And Transfer To Pc At A Distance Of 5-10 Feet. The Entire Display Screen Of Controller Should Wirelessly Appear In The Pc / Laptop Of User, To Monitor & Control From His Work Table. 5.16 • Electrical Requirement:230V / 50Hz. Ac Mains. 5.17 Refrigerated Water Cooling Circulating System 5.18 • Refrigerated Water Cooling Circulating System With Digital Display Of Temperature, 5.19 • Microprocessor Based Pid Temp. Controller, Temperature Range: 10°Cto 20ºc. 5.20 • Inbuilt Safety Features With Ce Certification To Fulfil All Statutory Requirement Of Good Laboratory Practice. Auto Over Temperature Protection / Auto Error Indication / Auto Sensor Break Protection, Over Load Protection. 5.21 • Ss Tank, Submergible Pump For Recirculation, Ms Powder Coating Housing 5.22 • The Instrument Should Be Approved Registered Brand & Shall Strictly Confirm To The Specifications With Relevant Brochure & Photograph As Per Specification. 6.00 Recirculating Chiller 6.01 Temperature Range: -10~100ºc 6.02 Precision:±0.2 6.03 Cooling Capacity At 20°C -800W 6.04 Interior Dimensions:150X160x150mm 6.05 Chamber Volume:4.5L 6.06 Electrical Requirement:220V 50Hz 6.07 Pump Flux:8L / Min 6.08 Power Consumption : 2300W 6.09 Microprocessor Temperature Controller 6.10 Audible And Visible Alarm For Temperature And Water Level 6.11 R134a Refrigerant, Imported Compressor With Interface To External Water Bath 6.12 Rs485 Connector To Connect Computer To Record The Parameters And The Variations Of Temperature. 7.00 Portable Gas Analyser ( Syn-Gas ) 7.01 Method Of Detection : Ndir Infrared Sensor For Co, Co2 And Ch4 Electrochemical Sensor For O2 & H2 7.02 Ranges Available O2 0-25.0%, 0-50.0%, 0-100.0% Co 0-10.0%, 0-50.0%, 0-100.0% Co2 0-10.0%, 0-50.0%, 0-100.0% Ch4 0-50.0%, 0-100.0% H2 0-5.0% 7.03 Resolution : 0.1% For All Gases 7.04 Accuracy & Repeatability : ± 2% Of Reading For All Gases 7.05 Drift : Less Than 2% Of Full Scale Per Month 7.06 Response Time ( T-90 ) : 20-30 Seconds To 90% Step Change 7.07 Ambient Temperature Range : 4 To 50°C 7.08 Power : 12V / 24V Dc Adaptor 7.09 Output Options : Rs 232 Interface For Data Logging 8.00 Sieve Shaker With Sieve 8.01 Heavy Duty ( Improved Model ) For 8 Inch Test Sieve 8.02 The Sieve Shaker Is Durable Constructed And Is Run By ¼ H.P. Electric Motor 220 Volts A.C. Through Reduction Gear. 8.03 Designed To Carry Upto 6 / 7 Test Sieve Of 200Mm Dia ( 8 Inch ) With One Set Lid & Pan. 8.04 It Produces Circular And Hammering Motion Is Given At Top. 8.05 It Reproduce Circular ( Revolution Approx.: 280 To 320 R.P.M And Tapping Approx.: 140 To 160 R.P.M. 8.06 No Foundation Required. 8.07 7 Nos. Of Test Sieve ( Dia 8 Inch ) Made-Up Of Brass With Different Sizes Such As 106 Μm, 150 Μm, 212 Μm, 250 Μm, 300 Μm, 500 Μm, 850Μm. 8.09 One Set Lid And Pan With Above Specification. 9.00 Moisture Analyser 9.01 Max. Capacity : 50 G 9.02 Readability ( Weight ) : 0.1 Mg 9.03 Readability Moisture : 0.0001% 9.04 Repeatability ( Sample 2G ) ( Sd ) : 0.05% 9.05 Repeatability ( Sample 10G ) ( Sd ) : 0.02% 9.06 Units Of Measurements : %M, %D, %R ( Ratio ) , Gm / Lt, %M Atro, %D Atro 9.07 Statistics : Method Wise For Each Individual 40 Methods Or Batch Wise For Each Individual 100 Batches For Last 999 Results 9.08 Technology : Infra Red Halogen 9.09 Temperature Range : Max. To 175°C ( Optional To 250ºc ) 9.10 Temperature Increment : Interval 1ºc 9.11 Heating Profile : Standard, Gentle, Rapid, Steps, High Temperature 9.12 Switch Off Criteria : Auto, Manual 9.13 Auto Method Development : Intelligent 9.14 Method Memory : 40 And Batch Memory : 100 9.15 Method Designation : Alpha Numeric 9.16 Serial Number : Yes 9.17 Compile : Yes ( Method Linking ) 9.18 Operating Temperature : 15ºc To 35ºc 9.19 Display : Graphical Lcd Display With Led Backlite 10.00 Filter Vacuum Pump 10.01 Wetted Parts 304 Stainless Steel, Free Air Capacity ( Lpm ) ≥28 Max Flow Rate ( Cfm ) ≥ 0.99 Max Flow Rate ( Litters / Min ) ≥28 Max Pressure ( Psi ) ≥ 60 Max Pressure ( Bar ) ≥4.14 Max Vacuum ( Mbar ) ≥ 500 Noise Level ( Db ) ≥ 68 Port Size ¼ Npt ( F ) 3 / 4 Hose Barb On Gauges Noise Level : 50.00 Db 10.02 Filtration Unit 10.03 Material Type: Glass Diameter: 50Mm Capacity: Upper Chamber-500 Ml, 1000Ml, Lower Chamber-500Ml Sintered Crucible Nylon 66 Membrane & Filter, Filterpaper Nontoxic, Unbreakable Polysulfone Funnel Is Used In Microbial And Particulate Analysis. Funnels Do Not Leak After Repeated Autoclaving Removal Membrane Support Plate Is Designed To Provide Maximum Flow Rate And Through Put. Filtration Assembly Made Of Borosilicate Glass With Fritted Glass Filter Base The Base Design Has An Integral Vacuum Connection Located Above The Filtrate Drip To Prevent Contamination Of The Vacuum Line From Droplets The Filtration Base Has A Silicon Stopper, Anodized Aluminum Spring Clamp Facilitates Analysis Of Particulate Or Biological Contamination Of Vacuum Filtering Liquid The Scaled Funnels Simplify Dosing And Analysis 11.00 Lambda 365 Double Beam Uv Spectrophotometer Compatible Accessories Kit 11.01 50 Mm Trans / Reflect Sphere High Sens Used For Measuring The Diffuse Reflectance ( Sce ) , Total Transmittance, Diffuse Transmittance And Performing Color Analysis. It Has A Spectral Range Of 230-1100 Nm ( Uv And Visible ) . Its Port Size Is 10.00 Mm And The Spectral Bandwidth Is 20Nm. 11.02 Powder Sampling Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 9
7.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
8.
Housing Urban and Rular Development #10427022 Price Bid
Construction Of Sump Well Pump Room And Sitc Of Rotary Lobe Pump Sets Along With Related Eandm Equipments At Rahim Khan Road Nizamuddin East New Delhi Under Ser-1 Civil And Electrical Work-SH-I Pump Set WorkSupplying, installation, testing and commissioning of Positive displacement Rotary Lobe Pump for draining/dewatering of storm water/sewer water compatiblefor VFD (variable frequency drive) having minimum discharge 500 m3 /hr at 68Hz and 170 m3/hr at 25 Hz for 10 mtr. head and 5 mtr. suction Lift capacity complete withGeared Motorwith minimum power 45 kW/60 HP, 4 Pole suitable for operation on 415 Volt 50 Hzas per additional specification etc. as required. 2 Supplying, fabrication & installation of45KW VFD AUTO CONTROL PANEL made out of CRCA sheet steel of thickness 2mm for load bearing members, 1.6mm for non load bearing section with necessary stiffeners as required. 3 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 4 250 m.m dia 5 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required: 6 250 m.m dia 7 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 8 40 mm dia 9 80 mm dia 10 250 mm dia (wall thickness 6.3 mm) 11 450 mm dia (wall thickness 7.0 mm) 12 Fabrication, Supplying, Installation Testing & commissioning of automatic motorised Mechanical Coarse Bar Screen Suitable for channel dimension:i) Channel width: 1000mmii) Channel Depth: 3500 mmiii) Water Depth: 1500 mmiv) Bar Spacing: 20 mmv) Bar size : 12X6X50 mm vi) Angle: 75 Degreevii) MOC: SS304 Peak Flow/ Screen: 27MLDi/c Supplying, Installation, Testing & commissioning of 1No relay based control panel made out of 2mm thick CRCA sheet for 2Nos. Mechanical Coarse Bar Screen & 1No.Belt Conveyor etc. complete as required. - 13 Supplying, Installation, Testing & commissioning of Differential Level Sensorcomprises of Two Ultrasonic Level Sensors and One Differential Transmitter for Mechanical coarse bar screenetc. complete as required. 14 Supplying, Installation Testing & commissioning ofBelt Conveyor of size 600 mm width and2000mm Length i/c accessories for screen etc. complete as required. 15 Supplying, Installation Testing & commissioning of Gate Assy FG A101 Cast Iron Side Wall Embedded Oen Channel Gate (101) Size: 1000(W) X 1000 (H) mm Suitable for 1.75 m Seating water head (From invert Level) , Flush Bottom Closure Arrangement , Manually operated, Close Top Frame Gate etc. complete as required. 16 Supplying, Installation Testing & commissioning of Ultrasonic Level Transmitter with 4 ANSI PP Flange etc. complete as required. 17 Supplying, Installation Testing & commissioning of Local Control Stations for Pump Motors having following accessories i/c making connections etc. complete as required:a)DP MCB, 10kA, C-Curve for Control, 6A;: 1 No.b)Ampere meter, SIF-96, CI-1, Aux Supply 230V AC; 4-20mA I/P;1 No.c)Indicating Light-RED for ON;1 No.d)Indicating Light-AMBER for TRIP;1 No.e)Push Button with 1 NO contact - GREEN for VFD START;1 No.f)Push Button with 1 NC contact - RED for VFD STOP;1 No.g)Push Button with 1 NC contact - Mushroom head RED;1 No.h)Thermistor Relay 252 PMTG;1 No.i)Control Terminals, 2.5 sqmm; 6A;22 Nos. 18 SH-II Diesel Generator SetSupply, installation, testing and commissioning of Silent Type, CPCB IV + emission compliants Diesel Generating set having Prime Power Rating of 200 KVA, at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 Phase system & for 0.85 Load Factor with all necessary equipments and accessories and consisting of followings :(a)Diesel EngineDiesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50 % RH & at 1000 meterMSL and conforming to BS 5514, BS 649, IS 10000(amended upto date), capable of taking 10 % overloading for 1 hourafter12hourofcontinuousoperation.Theenginewillbefittedcompletewithall accessories as per specifications .(b)Enginemountedinstrumentpanelfittedwithandhavingdigitaldisplayforthe following :-(i) Start stop switch with Key (ii) Water temperature indication (iii) lubrication oiltemperatureindication(iv)lubricationoilpressureindication(v) Batterycharging indication (vi) RPM indication (vii) Over speed indication (viii)Low lube oil trip indication(ix) Engine hour indication. 19 (c)AlternatorSynchronous alternator rated at 200 KVA, 415V, at 1500 RPM, 3 Phase, 50Hz, AC Supply with 0.8 lagging power factor at 40 Degree C, 50% Relative Humidity & at 1000m above MSL. The alternator shallbehavingSPDPenclosure,brushless,continuousduty,self-excitedandself-regulatedthrough AVR, confirming to IS: 4722 /BS : 2613suitable for tropical conditions and withF/H insulation.(d) Base Frame &foundation: Both the Engine & alternator shall be mounted on suitable baseframemadeofMSchannelwithnecessaryreinforcementwhichshallbeinstalledon suitablecementconcretefoundationandvibrationisolationarrangementasper recommendations of manufacturer.(e) Fuel Tank : Daily service fuel tank ofminimum 385 Ltr capacity fabricated out of 3mm thick MS sheet complete with all standard accessories and fuel piping between fuel tank & diesel engine with MS class C Pipe of suitable dia complete with valves, level indicators, and accessories as required as per specification.(f) Exhaust System : Dry exhaust manifold withsuitable exhaust residential gradesilencer . 20 (g) Starting system : 24V DC starting system comprising of starter motors, voltage regulator and arrangementforinitialexcitation,completewith suitableno. of batteries(25Plates,180 AmpsHour Capacitylead acid type) as required as per specification.(h) Acoustic Enclosure : Acoustic and weather proof enclosure with arrangement for fresh airintakeforcoolingoftheengineandalternator,extractiondischargeofhotairinto atmosphere as per specifications. 21 AMF Panel(i) Fabricating,Installation, Testing & Commissioningofautomaticmainsfailurecontrolincludingautobypasspanel,suitable for 200 KVAsilenttypeDGsetcompletewithrelays,timers,setofCTs,formeteringand protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH& Provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to Diesel Engine and elsewhere, if required, all complete and interlocking including the following :-(a) 3 nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release.(b)Auto / manual /test/off selector switch.(c) 2 nos. over voltage relay, 2 nos. reverse power relay and 2 nos. under voltage relay.(d)1 no. Auto mains failure relay(e) 3 sets of current transformer15P 10 accuracy for protection andclass 1, 15VA class-Ifor metering and. AMF Relay.(f) Energy analyzer unit to indicate current, voltage, frequency power factor and KWH.(g) Indicating lamps for load on mains and load on set.(h) Fuse for instruments.(i) Battery charger, complete with all accessoriesand Ammeter,voltmeter etc. 22 (j) Supply failure& restoration timer(k) Main supply failure monitor(l) Control unit with three impulse automatic engine start/stop and failure to start lock out.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator.(o)Aux. contactor 2NO+2NC(p) Audio/Video annunciation for :(i) High water temperature.(ii) Low lubricating oil pressure.(iii) Engine over speed(iv) Engine fails to start.(v) Full load/ Maximum load warning. 23 Main LT PanelSupplying, installation, testing & commissioning of LT panel of minimum front area 3.15 sq. mtr. and depth not less than 45 cm, made out ofCRCA Sheet Steel 2mm for section with necessary stiffeners as required. Free standing, self supported, floor mounting, single front, indoorinstallation, non draw out and compartmented. ISMC-100 fabricated channel frame with undrilled holes.Bottom with undrilled detachable 3mm gland plate as per order .Welding will be carried out with no external deposition of welded material in particular places and there will not be any gap between the welded materials.Siemens Grey RAL 7032CRCA Structures shall be pre-treated in seven tank chemical process, heated in baking oven.Minimum 60 micron of approved shade (RAL-7032).230V AC for Main LT Panel and Other Panels415+/- 5% , 50Hz+/-5%, 3 Phase 4 Wire 50KA – 1 Sec TPN Aluminum Electrolytic Grade ( E-91E) busbar shall be provided as per suitable sze, duly supported on SMC/DMC, busbar supports & insulated with color coded heat shrinkable sleeve. Power wiring will be through Vertical Bus -Bar and 1.1 KV grade PVC multistrand copper flexible cable . All control wiring will be done by 1.5 sq mm copper flexible PVC multi strand wire. CT wiring shall be carried out with 2.5 sq mm copper flexible PVC multistrand wire.1. All R,Y,B,N phases will be Red, Yellow , Blue & Black 2.All control wiring will be Grey colour. Earthing shall 24 be be with Green color wire.3.C.T. - Wiring through Red, Yellow, Blue, Black coloured wiring with shorting link type terminals.EPDM gasket provided at all joints, doors & covers to make panels dust & vermin proof (IP-52)Section-I(a) INCOMER :-1No. 4nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release. Ics=100%Icu i/c extended rotary handle and spreaders and all required accessaries Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch & back up HRC fuses/MCBs … complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set(b) 400 AOnload Change over SwitchIcs=100%Icu i/c extended rotary handle and spreaders and all required accessories- 1setIndicating lamp On, OFF, TRIP /R/Y/B/Ready to close complete 1set(c) OUT GOINGS:- 4Nos. 100A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etc complete as reqd. 25 Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch etc complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set3 Nos. 63A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etcwith indicating Lamps complete as reqd. 26 SH-III EI Work Supplying & Laying of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following size on cable tray as required. 27 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable (clamped with 40x3mm MS flat clamp) 28 3 X 50 sq mm (clamped with 25x3mm MS flat clamp) 29 Supplying, Laying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cableof 1.1 KV grade of following sizes on wall surface etc. as required. 30 4X25 Sq. mm. (clamped with 1mm thick saddle) 31 Supplying & Laying and fixing of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following sizedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 32 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable 33 Supplying and Laying of XLPE insulated and PVC sheathed Copper conductor armoured Power Cable of 1.1 KV grade of following size on cable tray as required. 34 4x4 Sq.mm. 35 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 36 3½ X 240 sq. mm (62mm) 37 3 X 50 sq. mm (32mm) 38 4 X 25 sq. mm (28mm) 39 Supplying and drawing following size of PVC insulated copper conductor multicore cable of following size on cable tray as required. 40 10 core 1.5 sq.mm 41 24 core 0.5 sq.mm 42 4 core 0.5 sq.mm 43 2 core 1.5 sq.mm 44 6 core 0.5 sq.mm 45 3 core 0.75 sq.mm 46 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 450 mm width X 50 mm depth X 2.0 mm thickness 49 EarthingEarthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 50 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 51 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithbrassnut,bolt,spring,washerexcavationandre-fillingetc.as required. 52 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 53 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithG.I.nut,bolt,spring,washerexcavationandre-fillingetc.as required. 54 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. asrequired. 55 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 56 Group C 57 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 58 3 x 4 sq. mm 59 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 60 25 mm 61 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 62 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 63 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 64 4 way (4 + 12), Double door 65 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 66 Single pole 67 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 68 63 amps 69 Supplying, Installation, testing & commissioning of weather proof LED Corrosion resistant battentype LED fitting of following wattagewith IP65 body made out of polycarbonate housing & opal diffuser with better thermal managementCCT-5700°KLumen Efficacy ≥110 Lm/W Power Factor≥ 0.95, CRI≥70, with constant current driver etc. complete as reqd. 70 36 Watt (4 feet ) 71 SITC of 450 mm heavy duty Exhaust Fan 1400 RPMsingle phase 240 Volt 50 Hz in the existing opening, complete with heavy duty louver/ shutter i/c making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning & earthing etc. as required 72 SITC of 600mmwall mounted fan having 3 nos. of blades, 1440RPM etc complete as reqd. 73 SH-IV AMCAMC for pump sets, Motor control panel and other accessories starting after satisfactory completion defect liability period from date of completion and commissioning of the pumping system.Annual Comprehensive maintenance for all 3 Nos. Pump sets, Motor, VFD Auto control panel, Mechanical Course Bar Screen, Differential Level sensor, Ultra Sonic Level Transmeter, Belt conveyor, Gate assembly including all accessories and consumables etc. all complete and as per site requirement as per Engineer-in-charge. 74 For 1st Year (Free Maintenance period) 75 For 2nd Year 76 For 3rd Year 77 Comprehensive maintenance of 200 KVA Silent type DG Set with AMF Panel. Annual Comprehensive maintenance of 200 KVA DG set and its accessories with AMF Panel i/c repairing, servicing, cleaning, checking and Descaling with replacment of following consumable parts i.e oil filter, fuel filter, air filters, coolant, lube oil, coolant filter, battery water, V Belts and batteries etc. complete and as per site requirement as per Engineer-in-charge. 78 For 1st Year (Free Maintenance period) 79 For 2nd Year 80 For 3rd Year 81 Civil WorkDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 82 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 83 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. 84 All kind of soil. 85 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 86 Providing and laying in position ready mixed or site batched design mix cement concrete for plai plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads: but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 87 Concrete of M10 grade with minimum cement content of 220 kg /cum 88 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 89 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 90 Suspended floors, roofs, landings, balconies and access platform 91 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 92 Edges of slabs and breaks in floors and wallsAbove 20 cm wide 93 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana / Ordinary Portland /Portland Slagcement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade withminimum cement content of 330 kg /cum 94 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 95 Thermo-Mechanically Treated bars of grade Fe-500D or more. 96 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 97 Cement mortar 1:4 (1 cement : 4 coarse sand) 98 12mm cement plaster of mix 1:4 (1cement:4 fine sand). 99 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 100 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 101 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 102 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 103 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Ordinary roack 104 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 105 Providing and fixing soil, waste and vent pipes : 100 mm dia. : 106 Sand cast iron S&S pipe as per IS: 1729. 107 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 108 Circular shape 450 mm dia 109 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 110 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 111 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 112 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 113 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm : 114 Sand cast iron S&S as per IS - 1729 115 Providing and fixing plain bend of required degree : 100 mm 116 Sand cast iron S&S as per IS - 1729 117 Providing and fixing single equal plain junction of required degree: 100x100x100mm, 118 Sand cast iron S&S as per IS-1729. 119 Providing and fixing terminal guard: 100mm : 120 Sand cast iron S&S as per IS:1729. 121 Providing and fixing collar:100mm : 122 Sand cast iron S&S as per IS:1729. 123 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 124 100mm : 125 Providing and fixing trap of self cleanising design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet and 100mm outlet : 126 Sand cast iron S&S as per IS:3989. 127 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 128 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 129 25mm dia nominal bore. 130 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tees including cutting andthreading the pipe etc. complete : 131 25 to 40mm nominal bore. 132 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 133 32mm dia nominal bore. 134 Providing and fixing C.P. brass bib cock of approved quality confirming to IS :8931 : 135 15mm nominal bore. 136 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS:8931 : 137 15mm nominal bore. 138 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 139 25mm nominal bore. 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure with plastic floats : 141 25mm nominal bore. 142 Providing and fixing brass ferrule C.I. mouth cover including boring and taping the main : 143 25mm nominal bore. 144 Providing and fixing unplasticised PVC connection pipe with brass unions : 45cm length : 145 15mm nominal bore. 146 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 147 Providing and fixing PTMT grating of approved quality and colour : Circular type : 148 100mm nominal dia. 149 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer : E.R.W. tubes. 150 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 151 Size of tile600x600mm. 152 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.Single socketed pipes : 153 110mm diameter. 154 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Bend 87. 5° : 155 110mm bend. 156 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Shoe (Plain) : 157 110mm Shoe. 158 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 159 Two or more coats on new work. 160 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : 161 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 162 Providing and laying in position ready mixedor site batched design mix cement concrete for plain cement concrete work;usingcoarse aggregateandfine aggregate derived from natural sources and usingrecycled concrete aggregate (RCA)as coarse aggregate and fine aggregate within thepermissible utilization,PortlandPozzolana / Ordinary Portland/Portland Slag cement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concreteto improvedurability andworkabilitywithout impairing strength;including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishingas per direction of the engineer-in-charge; for thefollowing grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level 163 Concrete of M25 grade with minimum cement content of 300 kg /cum.(Note: The permissible utilization of Recycled Concrete Aggregate (RCA) as coarse aggregate and fine aggregate is 25% each). 164 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 165 With 20x20 mm square bar 166 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 167 450 mm dia Ductile Iron Class K-9 pipes. *For use of bigger dia. pipes other than 450mm, net difference in basic rate as per applicable DSR shall be reimbursed to the contractor. 168 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 169 (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.Using rough kota stone. 170 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 171 Using rough Kota stone 172 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 173 Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : 174 Red sand stone slab40 to 50 mm thick 175 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 176 40 to 50 mm thick 177 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 178 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 179 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 180 Made of G.I. wire of dia 4 mm 181 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 182 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) 183 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 Modified estimated cost after using correction factor on DSR-2023 on account of GST @0.973 vide O.M. dated 08.08.2024.(i.e. 9720555 *0.973 = 9458100 185 Carrying out structural analysis and design of all civil work, Design of all E&M works, foundation and superstructure of work such as pump-room, UGT and Delivery line upto Barapullah Drainage etc. all complete and submission of input data, check print structural drawing, 6 Nos. prints with soft copy of analysis and drawings as per direction of Engineer-in-Charge by approved structural consultant agency. The profile of structural consultant shall be got approved from NIT approving authority. The structural design shall be comprehensive to enable easy servicing of pumps and other heavy equipment’s etc. possible. The Hydrological data shall be provided to the consultant for drainage design.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
9.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
10.
Health and Family Welfare #10357309 Price Bid
Tender For Who-Gmp Certified Medicine And Isi/Iso/Ce Certified Material, Pathological Items And Equipments , Name Of Items , Tab 5-Fluro Uracil500 Mg , Tab Abacavir 300 Mg , Tab Aceclofenac + Paracetamol + Serrapeptidase 100 + 325 +10Mg , Tab Aceclofenec 100Mg , Tab Acetazolamide 250 Mg , Tab Acetylsalicylic Acid (Aspirin) 25 Mg , Tab Acetylsalicylic Acid 150 Mg , Tab Acyclovir 200 Mg , Tab Acyclovir 800 Mg , Tab Albendazole 400 Mg , Tab Allopurinol300 Mg , Tab Allopurinol 100 Mg , Tab Alprazolam 0.25 Mg , Tab Amiodarone 100 Mg , Tab Amlodipine + Atenolol , Tab Amlodipine 10 Mg , Tab Amlodipine 5 Mg , Tab Amoxycillin+Clavulanic Acid (Amoxycillin 500 + Clavulanic Acid 125Mg) , Tab Artemether (A) + Lumefantrine (B) 20 Mg (A) + 120 Mg (B)1X6 , Tab Artemether (A) + Lumefantrine (B) 80 Mg (A) + 480 Mg (B) , Tab Artemether (A) + Lumefantrine (B)Oral Liquid 80 Mg (A) + 480 Mg (B)/5 M , Tab Ascorbic Acid (Vitamin C)100 Mg 100 Mg , Tab Aspirin 75 Mg , Tab Atenolol 50 Mg , Tab Atenolol100 Mg , Tab Atorvastatin 10 Mg , Tab Atorvastatin 40 Mg , Tab Azithromycin 250 Mg , Tab Azithromycin 500 Mg , Tab Baclofenbaclofen 40 Mg , Tab Betahistine 8 Mg , Tab Betamethasone 0.5 Mg , Tab Bicalutamide 50 Mg , Tab Bisacodyl 5Mg , Tab Bisacodylsuppositories 5 Mg , Tab Calcium Carbonate . 500 Mg , Tab Calcium Leucovorin50mg , Tab Calcium With Vitamin D3calcium Equivalent To 500 Mg & Vit. D3 250 Iu , Tab Capeciine500 Mg , Tab Carbamazepine 200 Mg , Tab Carbamazepine 200 Mg , Tab Carbimazole 10 Mg10strip , Tab Carboplatin450 Mg , Tab Cefixime 200 Mg , Tab Cefixime 50 Mg , Tab Cefpodoxime + Clavunate 200+125Mg , Tab Cefpodoxime- 200 Mg , Tab Cetirizine 10 Mg , Tab Cefadroxil 250 Mg , Tab Cefadroxil 500 Mg , Tab. Cefuroxime( 250 Mg) , Tab. Cefuroxime( 500 Mg) , Tab. Cefuroxime 500Mg + Clavunate 125Mg , Tab Chloroquine 250 Mg , Tab Chlorpromazine 100 Mg , Tab Chlorthalidone12.5Mg , Tab Chlorthalidone25mg , Tab Cinnarizine 25 Mg , Tab Ciprofloxacin 250 Mg , Tab Ciprofloxacin 500 Mg , Tab Ciprofloxacin + Tinidazole(250 Mg + 300 Mg) , Tab Ciprofloxacin+ Tinidazole (500Mg & 500Mg) , Tab Ciprofloxacin + Tinidazole(500Mg+600Mg) , Tab Cisplatin50 Mg , Tab Clarithromycin 250 Mg , Tab Clarithromycin 500 Mg , Tab Clofazimine 100 Mg , Tab Clofazimine 50 Mg 4 , Tab Clomiphene Citrate50 Mg , Tab Clonazepam 0.5 Mg , Tab Clopidogrel 75 Mg , Tab Clotrimazole (Vaginal )Pessary 500 Mg (With Applicator)Single , Tab Clozapine 25 Mg , Tab Clozapine 50 Mg , Tab Cyclophosphamide500 Mg , Tab Dapsone 100 Mg , Tab Deferasirox 250Mg , Tab Deferasirox 500 Mg30 , Tab Deferiprone500mg , Tab Deriphylline Sr 300 Mg , Tab Dexamethasone 0.5 Mg , Tab Diazepam 5 Mg , Tab Diclofenac 50 Mg , Tab Diclofenac 100Mg(Sr Tablet) , Tab Diclofenac 50Mg +Paracetamol 325Mg+Chlorzoxazone 500Mg , Tab Diclofenac 50Mg + Paracetamol 500Mg + Chlorzoxazone 250Mg(50Mg+500Mg+250Mg) , Tab Diclofenac Sodium + Paracetamol +Serratiopeptidase(50 Mg +325 Mg + 10 Mg) , Tab Dicyclomine 500 Mg , Tab Dicyclomine Hydrochloride 20 Mg , Tab Diethylcarbamazine 100 Mg , Tab Digoxin 0.25 Mg , Tab Digoxin 250 Mg , Tab Diloxanide Furoate 500 Mg , Tab Diltiazem 60 Mgl , Tab Diltiazemsr90 Mg , Tab Diltizem 30 Mg , Tab Diphenylhydantoin 30 Mg , Tab Dispersablehydroxyurea100 Mg , Tab Disulfiram 250 Mg , Tab Docetaxel120 Mg , Tab Domperidone 10 Mg , Tab Donepezil 5 Mg , Tab Doxorubicin50 Mg , Tab Drotaverine 40 Mg , Tab Empagliflozin25 Mg , Tab Enalapril Maleate 10 Mg , Tab Epirubicin100 Mg , Tab Erlotinib 150 Mg , Tab Escitalopram 10 Mg , Tab Ethamsylate250 Mg , Tab Ethinylestradiol (A) + Levonorgestrel (B) 0.03 Mg (A) + 0.15 Mg (B) , Tab Ethinylestradiol 0.01 Mg , Tab Ethinylestradiol 0.05 Mg , Tab Etophylline+Theophylline 100 Mg (Etophylline 77+Theophylline 23 )Mg , Tab Etoposide100 Mg , Tab Exemestine 25 Mg , Tab Ferric Carboxymaltose250mg , Tab Ferrous Ascorbate(100Mg. Elemental Iron+Folic Acid 1.5 Mg) , Tab Finofibrate160 Mg , Tab Finofibrate 40 Mg , Tab Fluconazole 150 Mg , Tab Flunarizine 5 Mg , Tab Fluoxetinecapsule 20Mg , Tab Folic Acid 5Mg , Tab Furazolidone 100 Mg , Tab Furusemide 40 Mg , Tab Gefitnib 250 Mg , Tab Gemciine1.4 Mg , Tab Glibenclamide 5 Mg , Tab Gliclazide 80 Mg , Tab Glimeperide 1 Mg , Tab Glimeperide 2 Mg , Tab Gutta Percha (Gp)30/Bottel , Tab Haloperidol 5 Mg , Tab Hydrochlorothiazid 12.5 Mg , Tab Hydrochlorothiazid 50 Mg , Tab Hydrochlorothiazide 25 Mg , Tab Hydroxychloroquine 200 Mg , Tab Hydroxyzine25 Mg , Tab Ibuprofen 400Mg , Tab Imatinib Mesylate400 Mg , Tab Imipramine 25 Mg , Tab Iron & Folic Acid Sugar Coatediron And Folic Acid Sugar Coateddried Ferrous Sulphate Ip Eq. To 45 Mg Ferrous Iron And 400 Mcg Folic Acid Ip (Pink Colored ) - , Tab Iron & Folic Acid Sugar Coatediron Folic Acid Sugar Coated (Blue ) Ferrous Sulphate Ip Equivalent To60 Mg Elemental Iron & 500 Mcg Folic Acid Ip , Tab Iron & Folic Acid Sugar Coatediron Folic Acid Sugar Coated (Red ) Ferrous Sulphate Ip Equivalent To60 Mg Elemental Iron & 500 Mcg Folic Acid Ip , Tab Isosorbide -5-Mononitrate 20 Mg , Tab Isosorbide Dinitrate 5 Mg , Tab Itraconazole/Capsule 100 Mg , Tab Ivermectin 12 Mg , Tab Ketorolac10 Mg , Tab Labetalol 100 Mg , Tab Lenalidomide 25 Mg , Tab Letrozole 2.5Mg , Tab Levetiracetam 250 Mg , Tab Levodopa (A) + Carbidopa (B) 100 Mg (A) + 10 Mg (B) Cr , Tab Levodopa (A) + Carbidopa (B) 100 Mg (A) + 25 Mg (B) Cr , Tab Levodopa (A) + Carbidopa (B) 250 Mg (A) + 25 Mg (B) , Tab Levofloxacin 250 Mg , Tab Levofloxacin 500 Mg , Tab Levonorgestrel 0.75 Mg , Tab Levocetirizine Tab 5Mg , Tab Levocetirizine + Monteleukast(5 Mg + 10 Mg) , Tab Levocetrizine 10 Mg, Montelucost 20 Mg , Tab Levocetrizine Hcl 5Mg + Ambroxol Hcl 75 Mg , Tab Levothyroxine 100 Mcg100per Bottle , Tab Levothyroxine 50 Mcg100per Bottle , Tab Linezolid 600 Mg , Tab Lithium Carbonate 300 Mg , Tab Loperamide 2 Mg , Tab Lorazepam 1 Mg , Tab Losartan10 Mg , Tab Mebeverine 200 Mg10 X 15 , Tab Medroxy- Progesterone 10 Mg , Tab Mefenamic Acid 250Mg + Drotaverine 80Mg , Tab Metformin + Gliclazide 500+80Mg , Tab Metformin 500 Mg , Tab Metformin-Sr1000mg10x15 , Tab Methotraxate50 Mg , Tab Methyl Ergometrine Maleate 0.125 Mg , Tab Methyldopa 250 Mg , Tab Methylprednisolone 16 Mg , Tab Methylprednisolone 4 Mg , Tab Metoclopramide 10 Mg , Tab Metoprololsr25 Mg , Tab Metoprololsr/Plain50 Mg , Tab Metronidazole 400 Mg , Tab Mifepristone 200 Mg1 Per Pack , Tab Misoprostal 100Mcg , Tab Misoprostal 200 Mcg4in 1 Pack , Tab Misoprostol 200Mcg (Oral/ Vaginal) , Tab Montelukast 5 Mg , Tab Morphine 10 Mg , Tab Morphine+I469sr/30 Mg , Tab Multivitamin Sugar Coated Nfi Formula Sugar Coated Vit A 2500 Iu , Vit C 50Mg, Calcium Pantothenate- 1Mg,Vit B1 2 Mg Vit B6 0.5 Mg Vit D3 200 Iu Vit , Tab Nicotinamide 50 Mg7 , Tab Nifedipine 10 Mg , Tab Nitroglycerine (Glyceryl Tri Nitrate)Sub-Lingual0.5 Mg10 , Tab Norfloxacin 400 Mg , Tab Norfloxacindispersible100mg , Tab Ofloxacin200 Mg , Tab Ofloxacin400mg , Tab Ofloxacin + Ornidazole(200Mg And 500Mg , Tab Ofloxacin 200Mg +Tinidazole 600Mg(Tab) , Tab Olanzapine 5 Mg , Tab Olanzapine10 Mg , Tab Ondansetron 4 Mg , Tab Ormeloxifene 30 Mg , Tab Oxaliplatin100 Mg , Tab Paclitaxel260 Mg , Tab Paracetamol 500Mg , Tab Paracetamol 650Mg , Tab Penicillin V (Phenoxymethyl Penicillin)250 Mg , Tab Phenobarbitone 30 Mg , Tab Phenobarbitone 60Mg , Tab Phenytoin/ Diphenylhydantoin 100Mg , Tab Povidone Iodinevaginal Pessary 200Mg10 X 10 , Tab Prednisolone 10Mg , Tab Prednisolone 20 Mg , Tab Prednisolone 20Mg , Tab Prednisolone 30Mg , Tab Prednisolone 40Mg , Tab Pregabalin 150 Mg , Tab Primaquine 15 Mg , Tab Primaquine 2.5 Mg , Tab Primaquine 7.5 Mg , Tab Propranolol 10 Mg , Tab Pyridoxine 10 Mg , Tab Pyridoxine 100 Mg , Tab Pyridoxine 40 Mg , Tab Quinine 300 Mg , Tab Rabeprazole 20 Mg , Tab Ramipril 2.5 Mg , Tab Ranitidine 150 Mg , Tab Riboflavin 5 Mg7 , Tab Risperidone 2 Mg , Tab Salbutamol 4 Mg , Tab Sitagliptin 50 Mg , Tab Sodium Valproate 500 Mg , Tab Sorafenib 200Mg , Tab Spironolactone 25 Mg , Tab Sucralfate 20 Mg , Tab Sulfamethoxazole And Trimethoprim800mg +160Mg , Tab Sulfamethoxazole+ Trimethoprim (Pediatric S) 400 Mg+80 Mg , Tab Sulfamethoxazole+Trimethoprim200mg +40 Mg , Tab Sulfasalazine 500 Mg , Tab Sumatriptan 25 Mg , Tab Sunitinib/Capsule50 Mg , Tab Sitagliptin 50 Mg +Metformine500mgs , Tab. Deferiprone 500Iu , Tab Tamoxifen 10 Mg3 , Tab Tamoxifen20 Mg , Tab Tapentadol 100 Mg , Tab Telmisartan 40 Mg , Tab Temozolamide 250 Mg , Tab Thiamine 100 Mg7 , Tab Thinylestradiol (A) + Levonorgestrel (B) 0.03 Mg (A) + 0.15 Mg (B) With Ferrous , Tab Tinidazole 300 Mg , Tab Tramadol 50Mg , Tab Tranexamic Acid 500Mg , Tab Trihexyphenidyl 2 Mg , Tropicacyl Plus Eye Drop , Tab Verapamil 40 Mg , Tab Vincristin1 Mg , Tab Vitamin. B Complex Nfi (Prophylactic) B1 2 Mg, B2 2Mg, B6 0.5 Mg, Niacinamide 25 Mg, Calcium Pantothenate 1 Mg , Tab Warfarin 1 Mg , Tab Warfarin 2 Mg , Tab Warfarin 5 Mg , Tab Zinc Sulphate Dispersible 10Mg , Tab Zinc Sulphate Dispersible 20Mg10 X 10 , Tab Zoledronic Acid4 Mg , Tab Zolpidem10 Mg , Cap Amoxycillin 250 Mg10 X 10 , Cap Amoxycillin 500 Mg10 X 10 , Cap Ampicillin 250 Mg10 X 10 , Cap Ampicillin 500 Mg10 X 10 , Cap Cephalexin 250 Mg10 X 10 , Cap Cephalexin 500 Mg10 X 10 , Cap Clindamycin 150 Mg10 X 10 , Cap Cloxacillin 125 Mg10 X 10 , Cap Cloxacillin 500 Mg10 X 10 , Cap Cycloserine 125 Mg10 X 10 , Cap Doxycycline 100Mg10x10 , Cap Hydroxyurea 500 Mg , Cap Nifedipine 5 Mg10 X 10 , Cap Pomalidomide 2 Mg , Cap Rifampicin 150Mg , Cap Rifampicin 300Mg , Cap Rifampicin 450Mg , Cap Rifampicin 600Mg , Inj Acyclovirinj 250 Mg/Vialvial , Inj Adenosineinj 3 Mg/ Ml -2 Ml Amp , Inj Adrenalineinj 1 Mg/ Ml1 Ml Amp , Inj Amikacininj 100 Mg/2 Ml2 Ml Vial , Inj Amikacininj 500 Mg/2 Ml Vial2 Ml Vial , Inj Aminophylline Inj 25 Mg/ Ml10 Ml Vial , Inj Amiodaroneinj 50 Mg/ Ml3 Ml Amp , Inj Amoxycillin+Clavulanic Acid (Amoxycillin 500 + Clavulanic Acid 100 Mg)/ , Inj Amphotericin B 50 Mgvial/Ampoules , Inj Ampicillininj 500 Mg/Vialvial , Inj Anti D Immunoglobulin For Iv/Im Use (Monoclonal)Inj 150Mcg1 Ml Vial , Inj Anti D Immunoglobulin For Iv/Im Use (Monoclonal)Inj 300Mcgpfs/Vial , Inj Anti Snake Venominj Polyvalent 10 Ml (Lyophilized)10 Ml Vial , Inj Antitetanus Immunoglobulinsinj 250 Iu/Vialvial , Inj Artesunateinj 60 Mg /Vialvial , Inj Artesunatepowder For Injection 120 Mg , Inj Atracurium 10 Mg/ Ml2.5 Ml Amp , Inj Atropine 0.6 Mg/ Ml2 Ml Amp , Inj Bendamustineinj 100 Mg , Inj Benzathine Penicilline12 Lakh Iu/Vialvial , Inj Benzathine Penicilline6 Lakh Iu/Vialvial , Inj Betamethasone 4 Mg/Ml1 Ml Amp , Inj Betamethasone Sodium Phosphateinj 4 Mg/ Ml1 Ml Amp , Inj Biphasic Isophane Insulininsulin Biphasic Aspart 30:70 100 Iu/Ml (Firm Has To Supply Compatible Pen Along With Cartridges As And When Required Without Any , Inj Bleomycininj 15 Mg , Inj Bortezomib 2 Mg , Inj Bupivacaine Hcl 0.5% 20 Ml Vial , Inj Caffeine Citrateinj 20 Mg/ Ml3 Ml Vial , Inj Calcium Gluconateinj 10%10 Ml Vial , Inj Carboprost (15-Methyl Pgf2a)Inj 250Mcg1 Ml Amp , Inj Cefotaximeinj 1Gm/Vialvial , Inj Cefotaximeinj 250 Mg/Vialvial , Inj Cefotaximeinj 500 Mg/Vialvial , Inj Ceftazidimepowder For Injection 1Gm , Inj Ceftazidimepowder For Injection 250 Mg , Inj Ceftriaxoneinj 1 Gm/Vialvial , Inj Ceftriaxoneinj 250 Mg/Vialvial , Inj Ceftriaxoneinj 500 Mg/Vialvial , Inj Chloroquineinj 40 Mg/ Ml5 Ml Amp , Inj Chlorpheniramineinj 10 Mg/ Ml10 Ml Vial , Inj Ciprofloxacininj 200 Mg/100 Ml100 Ml Ffs Bottle , Inj D-10 (Dextrose 10%)Iv Fluid (Dextrose 10%)500 Ml Ffs Bottle , Inj D-25 Injection (Dextrose)Iv Fluid (Dextrose 25%)100 Ml Bottle , Inj D-25 Injection (Dextrose)Iv Fluid (Dextrose 25%)500 Ml Bottle , Inj Decarbazine 200 Mg10 Mg /Ml , Inj Desferrioxamineinjection 500 Mgvial , Inj Dexamethasoneinj 8 Mg/2 Ml2 Ml Vial , Inj Dextrose 5%Iv Fluid(Dextrose 5%)500 Ml Ffs Bottle , Inj Dextrose With Salinei/V Fluid (Dextrose 5% + Saline 0.9%)500 Ml Ffs Bottle , Inj Diazepam 5 Mg/ Ml2 Ml Amp , Inj Diclofenac 25 Mg/ Ml3 Ml Amp , Inj Dicyclomine Hydrochloride 10 Mg/ Ml2 Ml Amp , Inj Diltiazeminjection 5 Mg/Ml , Inj Dobutamineinj 50 Mg/ Ml5 Ml Amp , Inj Dopamineinj 40 Mg/ Ml5 Ml Amp , Inj Doxorubicininj 50 Mg , Inj Drotaverine 40 Mg/2 Ml2 Ml Amp , Inj Drotaverineinj 40 Mg/2 Ml2 Ml Amp , Inj Duvadilan 5Mgvial , Inj Enoxaparin Inj 40 Mg Equivalent To-4000 Iuvial/Pfs , Inj Erythropoietininjection 10000 Iu/Ml , Inj Erythropoietininjection 2000 Iu/Ml , Inj Esmolol 10 Mg/Ml , Inj Etophylline +Theophylline 220 Mg/2 Ml (169.4+50.6 Mg)2 Ml Amp , Inj Fentanyl50 Microgram/Ml2 Ml Amp , Inj Ferric Carboxymaltose50mg/Ml20 Ml Vial , Inj Fluphenazineinjection 25Mg1ml Vial/ Ampoules , Inj Fulvestrantinj 500 Mg , Eye Drop Flurbiprofen+Methylcellulose , Inj Furusemideinj 10 Mg/ Ml2 Ml Amp , Inj Gentamicininj 40 Mg/ Ml2 Ml Amp , Inj Glucose (A) + Sodium Chloride (B)Injection 5% (A) + 0.9% (B)500Ml Ffs , Inj Glycopyrolate 0.2 Mg/ Ml1 Ml Amp , Inj Haloperidolinj 5 Mg/ Ml1 Ml Amp , Inj Heparin Inj 1000 Iu5 Ml Vial , Inj Hepatitis B Immunoglobulin100 Iu/Vialvial , Inj Human Chorionic Gonadotropininjection 10000 Iuvial Of 1 Ml Injection , Inj Human Chorionic Gonadotropininjection 5000 Iuvial Of 2 Ml Injection , Inj Hyaluronidase 1500Iu , Inj Hydrocortisoneinj 100 Mg/Vialdry Powder 100Mg/Vial , Inj Hydroxyethyl(6% Saline Solution For Infusion)Starch 6%Ip , Inj Hyoscine Butylbromide20mg /Ml1 Ml Vial/Amp , Inj Ifosfamideinj 1 Gm , Inj. Deferoxamine500mg/Vial , Inj Insulin Solubleinj 40 Iu/ Ml10 Ml Vial , Inj Irinotecaninj 100 Mg , Inj Iron Sucroseinj 100 Mg/5 Ml5 Ml Amp , Inj Iv Human Immunoglobin 5% Iv Ig(5Mg/100Ml Each), , Inj Ketamine 10 Mg/ Ml10 Ml Vial , Inj Labetalolinj 20 Mg/4 Ml4 Ml Amp , Inj Labetalolinjection 5 Mg/Ml , Inj Lignocaine 2% 30 Ml Vial , Inj Lignocaine+Adrenaline 2% + 0.005 Mg/ Ml30 Ml Vial , Inj Lorazepaminj 2 Mg/ Ml1 Ml Vial , Inj Magnesium Sulphate 500 Mg/Ml , Inj Mannitolinj 20%100 Ml Ffsbottle / 350 Ml Ffs Bottle , Inj Medroxy- Progesteroneacetateinjection 150 Mg1 Ml / Vial , Inj Mephentermine 30 Ml Vial Mg/Ml10 Ml Vial , Inj Meropenem500 Mgvial , Inj Methyl Ergometrine Maleate 0.2 Mg/ Ml1 Ml Amp , Inj Methylprednisoloneinjection 1000 Mg/Mlvial , Inj Methylprednisoloneinjection 500 Mgvial Of 4 Ml , Inj Metoclopramideinj 5 Mg/ Ml2 Ml Amp , Inj Metronidazole 500 Mg/100 Ml100 Ml Ffs Bottle , Inj Midazolam 1 Mg/ Ml 5 Ml Amp/ 10Ml Vial , Inj Morphine 10 Mg/ Ml1 Ml Amp , Inj Morphineinjection 15 Mg/Mlvial , Inj Naloxoneinj 0.4 Mg/ Ml1 Ml Amp , Inj Neostigmine 0.5 Mg/ Ml1 Ml Amp , Inj Nitroglycerine (Glyceryl Tri Nitrate)Inj 25 Mg/5 Ml5 Ml Amp , Inj Noradrenalineinj 2 Mg Base/2 Ml Amp.2 Ml Amp , Inj Ondansetroninj 2 Mg/ Ml2 Ml Amp , Inj Oxytocin Injection 5Iu/Mlinjection 5 Iu/Ml1 Ml Ampule , Inj Pantoprazoleinj 40 Mg/Vialvial , Inj Paracetamol150 Mg/ Ml2 Ml Amp , Inj Pemetrexedinj 500 Mg , Inj Pentazocine 30Mg/Ml1 Ml Ampule , Inj Pheniramineinjection 22.75 Mg/Ml2 Ml Vial , Inj Phenobarbitoneinj 200 Mg1 Ml Amp , Inj Phenytoininj 50 Mg/ Ml2 Ml Amp , Inj Phytomenadione 10 Mg/Ml10 Mg Ampule , Inj Pioglitazone15mg , Inj Piperacillin +Tazobactam 4.5 Gm/Vialvial , Inj Pralidoxime (Pam)Inj 25 Mg/ Ml20 Ml Amp , Inj Premix Insulin30:70 Injection (Regular:Nph)2 , Inj Premix Insulin30:70 Injection 40 Iu/Ml , Inj Promethazine 10 Mg/Mlone Injection 1 Vial , Inj Promethazine 50 Mg (25Mg/ Ml)2Ml Vial/Ampoules , Inj Propofal 10 Mg/Ml1 Ml /Vial , Inj Protamine 50 Mg/5 Ml , Inj Quinineinj 300 Mg/ Ml2 Ml Amp , Inj Rabies Immunoglobulin300 Iu/2 Ml2 Ml Vial , Inj Rabies Vaccine (Cell Culture) Id/Iminj 2.5 Iu/ Ml1 Ml Vial , Inj Ranitidineinj 50 Mg/2 Ml2 Ml Amp , Inj Ringer Lactatei/V 0.24 % V/V Of Lactic Acid ( Eq. To 0.32% W/V Of Sodium Lactate), 0.6 % W/V Sodiumloride, 0.04 % W/V Potassium Chloride And 0.027 % , Inj Risperidone50 Mgvial Of 2 Ml , Inj Rituximabinj 500 Mg , Inj Sodium Bicarbonate Inj7.5% W/V10 Ml Amp , Inj Sodium Chloride - Hypotonicinj N/2(0.45%)500 Ml Ffs Bottle , Inj Sodium Chloride - Isotonicinj 0.9% Isotonic(Equivalent To Na+154 M Mol/L, Cl+154 M Mol/L)100 Ml Ffs , Inj Sodium Chloride - Isotonicinj 0.9% Isotonic(Equivalent To Na+154 M Mol/L, Cl+154 M Mol/L)500 Ml Ffs , Inj Streptokinaseinjection 15 Lac/Vialvial , Inj Succinyl Choline 50 Mg/ Ml10 Ml Vial , Inj Surfactant Suspension 25 Mg/Ml100 Ml Vial , Inj Thiamineinjection 100 Mg/Ml1 Ml/Vial , Inj Thiopentone 0.5Gm Powder/Vial20 Ml Vial , Inj Topotecaninj 4 Mg , Inj Tramadol 50 Mg/ Ml2 Ml Amp , Inj Tranexamic Acid 500 Mg/5 Ml.5 Ml Amp , Eye Drop Tropicamide And Phenyephrine , Inj Trastuzumabinj 440 Mg , Inj Urokinase(5 Laciu)Vial , Inj Vancomycinpowder For 1 G , Inj Vancomycinpowder For Injection 250 Mg , Vvancomycinpowder For Injection 500 Mg , Inj Vecuronium 2 Mg/ Ml2 Ml Amp , Inj Verapamil 5 Mg/2 Ml , Inj Vinblastininj 10 Mg , Inj Vinorelbineinj 10 Mg , Inj Vitamin B12 ,Injection500 Mcg/Ml(30 Ml Amp/ Vial) , Inj Vitamin K11 Mg/0.5 Ml0.5 Ml Amp , Inj Water For 2 Ml Amp , Inj Water For 5 Ml Amp , Drop Atropine1% Eye Drops5 Ml Vial , Drop Boro-Spirit Ear Drops-0.183 Gm Boric Acid In 2.08 Ml Of Alcohol , Drop Carboxy Methyl Celluslose 10 Ml , Drop Carboxymethyl-Cellulosedrops 0.5%10 Ml/Vial , Drop Ciprofloxacineye / Ear Drop 0.3%5 Ml Vial , Drop Combo Ear Drop- Chloramphenicol 5% W/V+Clotrimazole 1%+Lignocainehydrochloride 2%Combo Ear Drop- Chloramphenicol 5% , Drop Dexamethasonedrop(0.1%, 5Ml),Eye 5Ml Eye Drop , Drop Fluconazoleeye3 Mg/Ml(10 Mlvial),Eye Drop10 Ml , Drop Gentamicin Ear(0.3%)5 Ml Vial , Drop Homatropine 2% , Drop Lantanoprost0.005%(5Ml),Eye 5Ml , Drop Moxifloxacin0.5% W/V(5 Ml),Eye 5Ml , Drop Moxifloxacin+Prednisolone Eye Drop , Drop Moxifloxacin+Dexamethasone Eye Drop , Drop Normal Salinenasal Drops: Sodium Chloride Drops 0.05% W/V , Drop Paracetamol- 125Mg/Ml15 Ml Bottle With Dropper , Drop Pilocarpine 4%5 Ml Bottel , Drop Pilocarpinedrops 1%5 Ml Bottel , Drop Pilocarpinedrops 2%5 Ml Bottel , Drop Phenyl Mercuric Nitrate And Sodium Chloride 5 , Drop Phenyl Mercuric Nitrate And Sodium Chloride 6 , Drop Gatifloxacin(0.3% ), Eye Drop , Drop Prednisolonedrops 1%10 Ml Bottel , Drop Sodium Aminosalicylate Granules10 Gm , Drop Timolol0.5% Eye Drops5 Ml Vial , Drop Tropicamidedrops 1%5 Ml Drop , Drop Wax Solvent Ear Benzocaine2.7% W/V10 Ml Bottel Drop , Drop Wax Solvent Ear Drops: Paradichloro- Benzene2 % W/V10 Ml Bottel , Drop Xylometazolinenasal Drops 0.05 %, , Drop Xylometazolinenasal Drops: Adult (0.1%) , Inhaler Halothane 250 Ml Bottle , Inhaler Isoflurane 250 Ml Bottle , Inhaler Oxygen , Inhaler Ipratropium Inhalation (Mdi/Dpi)20 Mcg/Dose Ipratropium Respirator Solution , Inhaler Tiotropium Inhalation(Dpi) 18 Mcg/Dose , Inhaler Tiotropium Inhalation(Dpi) 9 Mcg/Dose , Inhaler Salbutamol Inhaler 100Mcg/Dosemetered Dose Container , Ointment Hydrocortisone 0.5% , Ointment Hydrocortisone 1% , Ointment Povidone Iodine5% Ointment15 Gram Tube , Ointment Acyclovir3% -5Gm Tube , Ointment Gum Paint Tannic Acid 2% , Ointment Betamethasone 0.05% 15 Gm , Ointment Aceclofanac + Linsed Oil + Methyl Salicylate + Menthol 30Gm , Syp Dextromethorphan 10 Mg/5 Ml100 Ml Pack Bottle , Syp Albendazole200mg/5 Ml10 Ml Bottle , Syp Ambroxol Hcl 15Mg + Terbutaline Sulphate 1.25Mg + Guaiphenesin 50Mg 5Ml ((Additional Composition Of Menthol Also Acceptable) 100Ml Bottle), Syrup , Syp Ambroxol Hcl 15Mg + Terbutaline Sulphate 1.25Mg + Guaiphenesin 50Mg , Syp Amoxycillin+Clavulanic Acid (Amoxicillin 200Mg+ Clavulanic Acid , Syp Azithromycinsyp 200Mg/5Ml15 Ml Bottle , Syp Bromhexine Syp 4Mg/5Ml50 Ml Bottle , Syp Caffeine Oral Liquid 20 Mg/Ml , Syp Carbamazepine Oral Liquid 100 Mg/5 Ml , Syp Cefixime + Clavunate 50+31.25Mg , Syp Cefixime Oral Suspension 100Mg/5Ml10 Ml Bottle , Syp Cefpodoxime + Clavunate 30Ml , Syp Cephalexinsyp 125Mg/5Ml30 Ml Bottle , Syp Cetirizinesyp 5Mg/5Ml30 Ml Bottle , Syp Chloroquinesyp 160Mg /10Ml(50Mg/5Ml Base)60 Ml Bottle , Syp Chlorpheniramine Maleate (Paracetamol 125Mg + Phenylpherine 5Mg + Cpm 0.5Mg + Sodiym Citrate 60Mg + Menthol 1Mg) , Syp Codeineoral Solution 15 Mg/5 Ml60 Ml Bottle , Syp Diphenhydramine 100Ml , Syp Diethylcarbamazine Oral Liquid 120 Mg/5 Ml , Syp Domperidone1mg Per 1Ml Suspension30 Ml Bottle , Syp Doxycyclinedry50 Mg/5 Ml , Syp Gum Paint (Tannic Acid)2% W/V15 Ml Bottle , Syp Hydroxyzine 10 Mg/5 Ml , Syp Iron & Folic Acidsyp Iron Each 1 Ml Contains 20Mg Elemental Iron+Folic Acid , Syp Lactulosesolution 10 Gm /15 Ml100 Ml Bottle , Syp Levosalbutamol50mcg/Dose , Syp Levosulbutamol 100 Mcg , Syp Levocetirizine + Monteleukast((2.5 Mg + 4 Mg) / 5 Ml, 30 Ml Bottle) , Syp Levocetirizine + Monteleukast 2.5 Mg + 4 Mg / 5 Ml(60 Ml Bottle,Suspension),Suspension , Syp Metronidazoleoral Suspension 200 Mg/5Ml60 Ml Bottle , Tab. Isoniazid 150Mg , Tab. Isoniazid 300Mg , Tab. Pyrazinamide 500Mg , Tab. Pyrazinamide 400Mg , Tab. Pyrazinamide 500Mg , Tab. Pyrazinamide 750Mg , Syp Montelukast Syrup60 Ml Bottle , Syp Multivitamin With Protein 200 Ml , Syp Ondansetronsyp 2Mg/5 Ml30 Ml Bottle , Syp Ofloxacin + Ornidazole (50 Mg + 125 Mg) / 5Ml 30 Ml Bottle(30 Ml),Suspension , Syp Paracetamol 125Mg/5 Ml60 Ml Bottle , Syp Pediatric Solution Like Isolyte P, N/2 & N/5Pediatric Solution Like Isolyte P, N/2 , Syp Potassium Chlorideoral Solution 100Mg/Ml200 Ml Bottle , Syp Promethazinesyp 5Mg/ 5Ml60 Ml Bottle , Syp Salbutamol Syp 2Mg/5Ml60 Ml Bottle , Syp Sodium Valproate Each 5Ml Contains 200Mg200 Ml Bottle , Syp Sucralfate 1Gm/5Ml100ml Bottle , Syp Sulfamethoxazole+Trimethoprimoral Liquid ( 200Mg +40 Mg) / 5 Ml50 Ml Bottle , Syp Vitamin A 100000 Iu/Ml With Marked Spoon For 1Ml &2Ml100 Ml Bottle , Tube Atropine1% Eye Ointment3 Gram , Tube Atropinesulphate 1%, , 3 Gm , Tubebenzoyl Peroxidegel 5% , Tube Betamethasone Dipropionateointment 0.05%15 Gram , Tube Chloramphenicoleye Ointment 0.5%4G/5G , Tube Ciprofloxacineye Ointment 0.3%3/3.5 Gram , Tube Clotrimazole Cream2%W/W15 Gram , Tube Diclofenac 0.01 , Tube Diclogenac + Linseed Oil 3% + Methyl Salicylate 10% + Menthol 5% , Tube Duvadilan10 Mg10x50 , Tube Framycetin Sulphate1% Cream30 Gram , Tube Fusidic Acidcream/Ointment 2%5 Gram , Tube Lignocaine 2% 30 Gram , Tube Miconazolecream 2% W/W15 Gram , Tube Mupirocincream/Ointment 2%5 Gram , Tube Povidine-Iodine Germicidegargle 20% W/V , Tube Salicylic Acidointment 6% 30 Gm , Tube Silver Sulphadiazine Cream Usp 1% 25 Gram , Tab / Cap. Cycloserine 100Mg , Tab. Linozolid 600Mg , Protin Powder , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine (Age Group 15 Or Above)Tab Artesunate 200 Mg(3Tab) + Sulphadoxine 750 Mg(2Tablets) + Pyrimethamine , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine (Age Group 9 To 14 Years)Tab Artesunate 150Mg (3Tab)+ Sulphadoxine 500Mg (2 Tab)+Pyrimethamine 25Mg , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine(Age Group Between 1-4 Years)Tab Artesunate 50 Mg (3 Tab) + Sulphadoxine 500 Mg(1 Tab) + Pyrimethamine 25 Mg , Combo Pack With Mifepristone + Misoprostol(1 Tablet Of Mifepristone 200 Mg And 4 Tablets Of Misoprostol 200Mcg)Combi Pack , Budesonide Nebulising Suspension Containing Budesonide 0.5 Mg/2 Ml2 Ml , Jelly Glycerin Oral Liquid , Oral Suspension Amoxycillin125 Mg/5 Ml30 Ml Bottle , Oral Suspension Chlorpheniramineoral Liquid 2 Mg/5 Ml , Oral Suspension Ibuprofen 100Mg/5Ml60 Ml Bottle , Oral Suspension Valproateoral Solution 200Mg/5Ml100 Ml Bottle , Bleaching Powder Containing Not Less Than 30% W/W Of Available Chlorine (As Per I.P)Containing Not Less Than 30% W/W Of Available Chlorine (As Per I.P) , Glucose Packet 75 Mg For Ogtt Testglucose Packet 75 Mg For Ogtt , Reduced Osmolarity Ors Pkt. Who Formulao.R.S. Glucose- 75Meq,Sodium- 75M Eq Or M Mol /L,Chloride - 65Meq Or M Mol/L, Potassium- 20Meq Or M Mol/L , Citrate- 10M Mol/L Osmolarity -245M Osm/L,Dextrose 13.5G/L Sodium Chloride 2.6G/L Potassium , Hydrogen Peroxide Solution 6% , Povidone Iodine Solution 5%,100 Ml Bottle , Adult Brief Daiper Set- Made Of Ultra Absorbent Material With Leakage Barrier & Having Soft, Flexible Leg Elastic. With Wetness Indicator. Made Up Of Woodpulp, Sap, Absorbent Nonwooven Fabric. The Set Contatin Two Pcs Of Medium Daiper {Nominal Size 81Cm-111Cm} For Waist Size 31-44 & Three Pcs Of Large Daiper {Normal Size 85Cm-128Cm} For Waist Size 34-50 , A V Fistula Sterilized Twin Needle(17 G (Two Needle Pack)),Consumable , A.V Fistula Needle - 16 No , A.V Fistula Needle - 17 G , A.V. Blood Line (Post Haemodialysis Tubing) , A.V. Blood Line (Post Haemodialysis Tubing) , A.V. Blood Line (Post Haemodialysis Tubing) High Quality , A.V. Blood Line (Post Haemodialysis Tubing) High Quality , Abdominal Belt(32 Inch Each),Consumable , Abdominal Belt(34 Inch Each),Consumable , Abdominal Belt(36 Inch Each),Consumable , Abdominal Belt(38 Inch Each),Consumable , Abdominal Drain Set 28 No , Abdominal Drain Set 32 No , Abdonel Belt Lsstandard Quality , Absolute Alcohol (Ethanol)(1X500 Ml = 500 Ml),Consumable , Absorable Surgical Suture Rb Needle Size No 1-0,30 Mm Length -70 Cm , 12 Foils Per Packet , Polyglycolic Acid (Pga) , Absorbable Gelatine Sponge Ip 80Mm X 50Mm X 10Mm , Absorbable Surgical Suture Braided Polyglycolic Acid 3/8 Circle Reverse Cuttingg(12Mm 45 Cmspatulated Needle),Consumable , Absorbent Cotton Roll 100 Gm Each Consumable , Absorbent Cotton Wool Ip 500 Grms (Each)(Roll),Consumable , Acetic Acid - Solution(3% 100 Ml Bottle),Consumable , Acetone Detection Kit , Acetone Detection Kit(100 Gm),Powder , Acetone Solution Pack Of 2.5 Ltr , Acralic Board (Sainaj Board Acralic Sheet) , Acralic Board (Sainaj Board Acralic Sheet) , Ad Syringe(0.1 Ml),For Vaccine , Ad Syringe(0.5 Ml),For Vaccine , Adhesive Plaster Usp 7.5 Cm X 10 Mts/Roll Cloth Based , Adhesive Plaster Usp 7.5 Cm X 5 Mts/Roll Cloth Based , Adhesive Roll 1 Inch X 5 M / Roll Cloth Based , Adhesive Tape 7.5Cm X10(Mtr/Roll),Consumable , Advanced Rf Energy Hand Instruments Of 12Mm Shaft Diameter For Open Procedureswith Shaft Lengths(22Cm And Should Be Both Hand & Foot Activated),Consumable , Advanced Rf Energy Hand Instruments Of 5Mm Shaft Diameter For Laparoscopic Procedures With Shaft Lengths (35Cm And Should Be Both Hand & Foot Activated With Curved Tip),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Laparoscopic Procedure With Shaft Length 35Cm With 55Degree Articulation And Should Be Both Hand(Foot Activated),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Laparoscopic Procedure With Shaft Length 45Cm And Should Be Both Hand(Foot Activated With Curved Tip),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Open Procedure With Shaft Length 14Cm And Should Be Both Hand And( Foot Activated),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Open Procedure With Shaft Length 25Cm And Should Be Both Hand And(Foot Activated),Consumable , Advanced Rfenergy Hand Instrument Of 5Mm Shaft Diameter For Open Procedure With Shaft Length 35Cm And Should Be Both Hand And(Foot Activated),Consumable , Albumin600 Ml(Model Ba 400 System (Mfg Bybio System)),Consumable , Albumin600 Ml(Model Ba 400 System ,Consumable , Alchlol Absouite 500Ml (Ethanol) 99.9% , Alcohal Based Hand Sanitizer(500Ml Bottle With Dispenser),Consumable , Alcohal Based Hand Sanitizer(500Ml Bottle With Dispenser),Consumable , Alkaline Phosphatase (Alp) Dea 300 Ml(Model Ba 400 System (Mfg Bybio System)),Consumable , Alkaline Phosphatase Kit (Kinetic) 10X2.2Ml 44 Test/Kit Consumable , Alkaline Phosphate Kinetic 2*25 Ml(Semi Auto End Point),Consumable , Alkaline Phosphate(100 Ml (5 X 20)),Consumable , All Human (Bovine Aprotinin Free) Fibrin Sealant(1 Ml),Consumable , All Human (Bovine Aprotinin Free) Fibrin Sealant(2 Ml),Consumable , All Out Refill , All Out With Refill , Almehra Iron 6X3x1.5”, 22 Gauge , Alphacypermetherin 5% Wdp , Alt/Gpt 600 Ml , Alumeium Bartan , Aluminium Potassim Sulphate (Each),Consumable , Ambu Bag / Adult Each -1700Ml, With Oxygen Connecting Tube ,Should Be Supplied With A Carry Pouch , Ambu Bag Should Be Complete With Required Autoclavable Valves And Other Accessories,(Should Have Silicon Rubber Bellow To Withstand Autoclave At 134 Deg.C),Consumable , Ambu Bag / Resuscitator Silicon 200-250 Ml Infant Size-Each, With Oxygen Connecting Tube ,Should Be Supplied With A Carry Pouch , Ambu Bag Should Be Complete With Required Autoclavable Valves And Other Accessories,(Should Have Silicon Rubber Bellow To Withstand Autoclave At 134 Deg.C) Should Be Multiple Times Autoclavable), Consumable , Aminoacid (Essential) Infusion(10% 100Ml Ffs Bottle),Bottle , Ammonium Sulphate (Analar (Gr/Ar) (1X500 Gm = 500Gm), Consumable , Anc Table 6X3x3 Of Iron , Anteriar Veginal Wall Retractor , Anti A Sera Igm(10 Vial),Consumable , Anti Abd Grouping Serum 3X10mlconsumable , Anti B Sera Igm(10 Vial),Consumable , Anti Malaria Larva Oil Harbal Based , Anti-D (Polyvalent)(1X10 Ml),Consumable , Antiseptic Concentrate For Floor Clening Pack Of 50 Litt. Can , Apit(2X4 Ml),Consumable , Apo-A(100 Tests),Consumable , Apo-B(100 Tests),Consumable , Asdesive Lable For Sputam Container , Aso Kit(25 Test/Packet),Consumable , Ast/Got 600 Ml , Attandent Bed Powder Coted 84Lx24Wx18H , Auramine O , Auto Clave (Poratable) Single Drum Aluminum Seamless Construction Made Of Albminium Alloy With Turning On Lid Highly Polished. It Comes With One Stop Cock (Continus Bleeding Valve) Safety Valve And Pressure Guage Size 12X12X12X20 , Auto Cleanser For Cbc Machine(2 Liter),Consumable , Auto Dill Solution For Cbc Machine(20 Liter),Consumable , Auto Lyser Solution For Cbc Machine(500Ml),Consumable , Auto Pippets Fixed Volume 10 Micro Liters Each Syring , Auto Pippets Fixed Volume 10 Micro Liters Each Syring , Auto Pippets Fixed Volume 1000 Micro Liters Eachsyring , Auto Pippets Fixed Volume 1000 Micro Liters Eachsyring , Auto Pippets Fixed Volume 20 Micro Liters Each , Auto Pippets Fixed Volume 20 Micro Liters Each Syring , Autoclave Ss , Double Walled Size (12X22) With Stand (Manual) Isi Marked , Autoclave Ss , Double Walled Size (16X24) With Stand (Manual)Isi Marked , Autoclave Ss , Electric Operated Size (12X14)With Stand , Autoclave Ss , Electric Operated Size (12X20) With Stand , Autoclave Ss , Eletric Operated Size (12X22)With Stand , A-V Blood Lines With Av Pressure Transducer Protector For All Machines Types And Dialysers (Acceptable For Fitting To All Standard Dialysers), Set , A-V Blood Lines With Av Pressure Transducer(Acceptable For Fitting To All Standard Dialyzers ) With Side Tubing- (For Heparinization And Av Pressure Monitoring) Ce And Iso Certificate Essential With Protector For All Machines Types And Dialysers(Post-Pump Tubing Sets Options Medical Grade Clear Tubing Guarded Access Ports For Reduced Infection Risks Parts Of Superior Quality, Each),Consumable , A-V Blood Lines With Av Pressure Transducer(Acceptable For Fitting To All Standard Dialyzers ) With Side Tubing- (For Heparinization And Av Pressure Monitoring) Ce And Iso Certificate Essential With Protector For All Machines Types And Dialysers(Post-Pump Tubing Sets Options Medical Grade Clear Tubing Guarded Access Ports For Reduced Infection Risks Parts Of Superior Quality, Each),Consumable , Axjust Cooler Plastic Body Standard Size , B.B Silk (12 Foils/Pkt)(3/8 Rcut Needle 45 Mm Length 76 Cm, Size 2/0)),Consumable , B.B Silk Size-3/0 (12 Foils/Pkt)(3/8Cir Rcut Needle 26Mm Length 76 Cm),Needle , B.B Silk With 1/2 Cir Rb Needle Size:1/0 20 Mm Length 75 Cm Non Absorbable Surgical Sutures Usp Surgical Material , B.B Silk With 1/2 Cir Rb Needle Size:2/0 30 Mm Length 75 Cmsurgical Material , B.B. Silk 6 Reels X 25 Mts Length 25 Mts. Black Braided Silk Without Needle In Reels Non Absorbable Surgical Sutures Usp 3-0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels),Consumable , B.B. Silk 6 Reels X 25 Mts Length 25 Mts.Black Braided Silk Without Needle In Reels Non Absorbable Surgical Sutures Usp-, 2-0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels ),Surgical Material , B.B. Silk 6 Reels X 25 Mts Size:1/0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels),Surgical Material , Babcock- Laparoscopic 10Mm A Traumatic Babcock, Straight 360 Degree Rotating With Insulated Shaft, A Traumatic Jaws With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable , Babcock- Laparoscopic 5Mm A Traumatic Babcock, Straight 360 Degree Rotating With Insulated Shaft, A Traumatic Jaws With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable , Baby Diapers Small (10 Diaper Per Pkt) Standard Company , Baby Feeding Spoon , Baby Feeding Spoon Feeding Of Milk , Baby Oxygen Maskall Sizes , Baby Shuit , Baby Towile , Baby Tray Ss 15X18Of Ss With Cover Pack Of Of Ss With Cover , Bag Cayring (Bag) , Bag For Carrying Kit/Material During Home Visit , Balanced Salt Solution 500 Mlbottle(Each),Consumable , Barium Chloride 10% (500 Ml Bottle) , Barraquer Wire Speculum, Large(Num),Consumable , Basic Carbol Fuchsin For Afb Staining 25 Gm/Pkt , Basic Fuchine 25Gm (Dye Content 85% To 88%) , Basic Fuchisin(Sep.Chemical Name: Pararosaniline Hydrochloride,Chemical Structure: C20h20c1n3 Mol Wt:337.86, Dye Content: Approx 85%-88% &Dye Content Must Be Mentioned) Colour Metallic Green. , Battery 70D 26 Rmf For Vehicle , Bed Pan Female With Cover (Made Of Stainless Steel) , Bed Pan Male With Cover (Made Of Stainless Steel) , Bed Side Bench , Bed Side Locker Ss , Bedside Locker Standard Size Ss Top , Benedicts Qualitative Reagent(1X5 Lit),Consumable , Bilirubin (Direct) As 300 Ml ,Consumable , Bilirubin (Total) 600 Ml,Consumable , Bilrubin Total & Direct Auto 3X100ml (Span/Tulip/Erba) , Bio Hazard Labels , Bio Metric Attance Machin Menul Operated , Bio Metric Attance Machine Online Operated , Biochemistry Calibrator 5X5 Ml Consumable , Biochemistry Control Serum L1 5X5 Ml , Biochemistry Control Serum L2 5X5 Ml (Consumable , Biomedical Waste Collection Plastic Bag(Yellow)(450X450 Mm 55 Micron 100/Pkt),Consumable , Biomedical Waste Collection Plstic Bag(Black 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Black 900 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Blue 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Blue 900 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Red 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Red 900 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Yellow 750 X 900 Mm 55 Micron 100/Pkt),Bag , Biomedical Waste Collection Plstic Bag(Yellow 900 X 900 Mm 55 Micron 100/Pkt),Bag , Bio-Membrane( ),Consumable , Black Disinfectant Fluid90% Pure Pack Of 20 Litt , Black-Braided Silk With 1/2 Cir Cutting Needle 30Mm Length 75 Cm(1/0 12 Foils/Pkt),Consumable , Black-Braided Silk With 1/2 Cir Rb Needle 20 Mm Length 75 Cm 1/0 13 Foils/Pkt , Black-Braided Silk With 1/2 Cir Rb Needle 30 Mm Length 75 Cm 2/0 12 Foils/Pkt , Blanket For Baby , Blankets For Neonates , Bleaching Powder 25Kg Bag , Bleaching Powder Gr-Ii Is 1065/1989 With Upto Datepacked In 25 Kg Hdpe Bags Isi Marked Stable Consumable , Blood Culture Media Mycobacterium Spp(Bact/Alert Mp (Plastic)),Each , Bowelss Size 20 , Blood Administrations Set Adult , Blood Bag Refrigerator For 150 Bags Isi Mark Standard Company , Blood Bag Refrigerator For 300 Bags Isi Mark Standard Company , Blood Bag Refrigerator For 60 Bags Isi Mark Standard Company , Blood Bag Warmer , Blood Bag With Acd/Cpd Solution (Disposable Sterilised) With Needle(100 Ml),Bag , Blood Bag With Acd/Cpd Solution (Disposable Sterilised) With Needle(350 Ml),Bag , Blood Bank Refrigerator , Blood Cell Counter Key(Key),Consumable , Blood Culture Media Aerobic For Adult(Bact/Alert Fa Plus),Each , Blood Culture Media Aerobic For Pediatric(Bact/Alert Pf Plus),Each , Blood Culture Media Fungus- Bottles Per Year, Fungus Can Be Tested By All Quoted Bottles. In The Same Bottle Bacteria And Fungus Can Be Tested.; Fungus Can Be Tested By All Quoted Bottles. In The Same Bottle Bacteria And Fungus Can Be Tested.(-),Consumable , Blood Gluose (God/Pod) Semi Auto End Point(1000 Ml),Consumable , Blood Grouping Anti Sera A Monoclonal(10 Ml Vial),Consumable , Blood Grouping Anti Sera B Monoclonal : Antisera Should Be Transparent With More Than One Year Shelf Life At 2-6 C , It Should Give +++ Agglutination At 1.256 Dilution In 3-4 Sec With B Positive Cells 10 Ml , Blood Grouping Anti Sera B Monoclonal(10 Ml Vial),Consumable , Blood Grouping Anti Sera D Monoclonal :-Antisera Should Be Transparent With More Than One Year Shelf Life At 2-6 C, It Should Give +++ Agglutination At 1.256 Dilution In 3-4 Sec With D Antigen Positive Cells. 10Ml Vail (Eryclone Anti-D Igm) , Blood Grouping Anti Sera D Monoclonal(10 Ml Vial ,Consumable , Blood Transfusion Chair , Blood Urea (Bun) Uv(1000 Ml),Consumable , Blood Urea Reagent Kit(200Ml (2X100ml)),Consumable , Blood Urea(Arba),Consumable , Blood Vessel Introducers Needles 16G, Sterilized, Set , Bloting Paper(Paper),Consumable , Boiling Flask 2Lt , Boiling Flask 5Lt , Bottel Plastic 2Lt , Bovine Albumin (22% W/V)(1X5=5 Ml),Consumable , Bowel Baual Ss Size 8 Powder Coated , Bowl Plastic 50X30 , Bp Stument Cell , Bp Stument Marcury Isi Mark , Brain Thromboplastin For Prothrombin Time (Pt Reagent) 5Ml (Liquiplastin) , Broom Stick For Sputum Smear Prepration (8 Inches) , Brown Tap (2 Inches) , Bubble Cpap Machine , Bucket Brackets (For Hanging Set Of Single Fire Buckets) With Out Fire Bucket , Bucket Brackets (For Hanging Set Of Three Fire Buckets) With Out Fire Bucket , Burn Cage (Bed Cradle) , Cabinate Plain (Cr Sheet 1.00 Mm) Size 1675X840x480 Mm (Iron) , Cabinate Plain (Cr Sheet 1.00 Mm) Size 1980X915x480 Mm (Iron) , Cabinet Full Size (78X3619) Sheet Gauge 20 (Iron) , Calcium Arsenazo 600 Ml,Consumable , Capillary Tube 100 Piecesconsumable , Capillary Tube Biluribin Pack Of 100 Pieces , Carbol Fuchsin For Zn Stain (500Ml Bottle) (Becon) , Carbol Fuchsin For Zn Stain (500Ml Bottle) (Ranbaxy) , Carbol Fuchsin For Zn Stain (500Ml Bottle) (Star) , Carbolic Acid (Phenol) - Spc. Chemical Structure C6h50h, Molecular Wt: 94.11, Melting Point : 40 Digree C 2, Purity : 99.5% , Carbondioxide Gas In Medium Size Cylinder(B Type),Miscellaneous , Carbondioxide Gas In Small Size Cylinder(A Type),Miscellaneous , C-Arm Macchine , Cartain Complete(Cloth Silk With Ring And Stiching) , Catgut Chromic Size:2/0 Length 150 Cm , Catgut Chromic With 1/2 Cir Rb Needle 30 Mm Length 70Cm No. 1 -0, 12 Foils Per Packet , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 75Cm No. 1 Consumable , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 75Cm No. 2 Consumable(Each),Consumable , Cathetor Tray Ss With Cover 16X3 , Cassette(14 Inch X 17 Inch),Consumable For X-Ray , Cassette(8 Inch X 10 Inch),Consumable For X-Ray , Cc Camera 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera 2 Way Audio. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:-Cc-31/Bma-231/Hevs-209-3G/Hl110/Va- 2W380/Al-Col-106/Vaccs 200 , Cc Camera, 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera With Supply. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:-Cc-30/Bmc-430/Hev 20 01 /Hl109/Va-Ccs- Tvl2380/Al-Col-105A/Vaccs380s , Cc Camera, 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:- Cc-72/Bmc-429/Dy-3723 Lph/Hl108/Va-Tvl380/Al-Col-104/Vaccs380 , Cc Camera, 10.1 Mega Pixle Cmos Sensor, Integreated Cleaning System, 2.5 Lcd Screen With 230K Pixle, 1600 Viewing Angle, High-Precision 9 Point Af System, Picture Style Image Processing Parameters, Digic Ii Image Processor With 0.2 Sec Start Up - (Each) , Cc Camera, 16 Channel Color Digital Video Recorder, 500 Gm Hdd, Full Triplex, Real Time Display (30 Frame Per Second) Make:- Impex/Sparsh/Grovers/Hinum/Vvantage/Alpha/Vision. Model:-Dv-62/Mcd-62/Dvr-29- Hk/Hl205dvr/Va-Hd500/Al-4C/B2616v , Cc Camera, 16 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cctv Cable, 3 Core + Coaxialfor 2 Way/Silent Camera, Make:- Impex/Sparsh/Grovers/Hinum/Vvantage/Alpha/Vision/Isi Model:-C-32/Cc-3/Alc-3C/Isi , Cd/Dvd Player , Ceiling Shadowless Lamp Double Dome Isi Marked , Ceiling Shadowless Lamp Single Domeisi Marked , Cell Clean For 5-Part Hematology Analyser All Model Consumable , Cell Pack For 5-Part Hematology Analyser All Model,Consumable , Cell Pack, Reagent Pack For Cell Counter((Erma And Mindrug) Complete Set),Consumable All Instement , Centeral Oxygen Supply For 10 Bedcomplete Fitting , Centeral Oxygen Supply For 30 Bedcomplete Fitting , Centeral Oxygen Supply For 5 Bed Complete Fitting , Central Venous Catheter Kit Single Lumen 18 G , Central Venous Catheter Kit(Single Lumen),Kit , Centrifuge Machine -12 Tube With Digital Display & Timer & Rpm , Centrifuge Machine -8 Tube With Digital Display & Timer & Rpm , Cervical Collar/Each-Soft, Medium Sized , Cervical Cotter , Chair Cushion Foam Thickness 3 With Cotton Cover Box Type , Chikungunya Card Test 1 Gg + 1 Gm (25 Test/Kit) , Chikungunya Card Test 1 Gg + 1 Gm (30 Test/Kit) , Children Toys 1- Jsvy] /Kkxs Ls [Khpus Okys F[Kyksus 2- Fcfymax Cykwdl] 3- Ckwdj Lcth ,Oa Qyksa Ds Vkdkj Okys Iykflvd F[Kyksus Vkfn 4- >Qu&>Qu 5- Iykflvd Ckwy , Chloroquine Solution 4 % Pack Of 5Ltr , Cholesterol600 Ml Consumable , Cholesterol Hdl Direct 160 Ml,Consumable , Cholesterol Kit End Point Enzymatic Kit 50 Test/Kit , Cholesterol Kit End Point Enzymatic Kit 5X20ml 200 Test/Kit , Cholestreol Kit Pack Of 10X10ml (Span/Tulip/Erba) , Chromic Catgut (12 Foils/Pkt)(Size:1/0 Length 150 Cm),Consumable , Chromic Catgut No 1.0 Round Dody, 40 Mm 12 Foils/Pkt , Chromic Size - 1, (12 Foils/Pkt)(1/2 Cir Rb Needle 40 Mm, Length 76 Cm),Needle , Chromic Size - 1, 12 Foils/Pkt(1/2 Cir Rb Needle 45 Mm, Length 100 Cm),Needle , Chromic Size - 1/0 (12 Foils/Pkt)(3/8 Cir Rb Needle 40 Mm, Suture Length 76 Cm),Needle , Chromic With 1/2 Cir Rb Needle 30 Mm Length 76Cm, 2-0 Usp, Absorbable Surgical Suture Surgical Material 12 Foils/Box , Chromic With 1/2 Cir Rb Needle 40 Mm Length 76 Cm (With Needle) ) Absorbable Surgical Sutures Usp,(Size 1, 12 Foils/Pkt),Surgical Material , Chromic With 1/2 Cir Rb Needle Size:1/0, 30 Mm Length 76Cm Absorbable Surgical Suture Surgical Material , Chromic With Cd Rb Needle 30 Mm Length 76 Cm Size:2/0 Absorbable Surgical Suture Surgical Usp, 12 Foils/Boxmaterial , Chromic With Cd.Rb Needle Absorbable Surgical Suture (12 Foils/Pkt)(40 Mm Length 76 Cm Size:1/0),Surgical Material , Chromic With St Rb Needle (12 Foils/Pkt)(60 Mm Length 76 Cm Size:2/0),Consumable , Cidex – 5Lter (2% Glutaldyhide) , Cidex Tray 10X5x3 , Cidex Tray 17X5x39 , Cidex Tray 26X53 , Cidex Tray 36X5x3 , Citric Acid Analar/Gr/Ar (1X500 Gm = 500Gm),Consumable , Cleanac-3 4000 Pack Size 5L(Cell Counter (Model No- Mek-6420P-Japan)),Consumable , Close Wound Drainage Device Under Negative Pressure(Closed Wound Suction Unit) Size 200 Ml(Catheter Size 18, Each),Consumable , Coagulometre Single Chanel , Coline 500Ml , Collagen Drysheet(20X40cm Sheet),Consumable , Collagen Drysheet(10X10cm Sheet),Consumable , Collagen Drysheet(15X30cm Sheet),Consumable , Collagen Wet(6X6 Cm),Sheet , Collection Vail 2Ml Pack 100 , Collection Vail 5Ml Pack 100 , Colorometre Digital , Colour Vision Chart , Complete Delivery Kit-1Plastic Desposable Gown (Non Woven Plastic Laminated,Leak Proof)-2(4*4),(2).Disposable Goggles For Protection Of Eyes-2 (Free Size),(3).Face Mask-2 Free Size,(4).Plastic Disposable Cap(Non Woven Plastic Laminated,Leak Proof)(1Pair,(5).Long Gloves Elbow Length-2Pairs(6 1/2 And 7),(6)Disposable Shoe Covers,Till Calf(Plastic)-2Pair(Free Size)As Per Attached Specification),Consumable [987797] , Computer Table (Size 4X2.6) With All The Fitting Of Parts , Computer Table 4’X2’ With All Fitting Of Parts , Con. (Hno3) Nitric Acid (2.5 Liter),Consumable , Conc Hcl (1X500 Ml = 500 Ml),Consumable , Conc Washing Solution500 Ml All Model Consumable , Conical Flask 2.5 Ltr , Conical Flask Cap. Of500ml Flat Bottal , Conical Flask Cap. Of 100Ml Flat Bottal , Conical Flask Cap. Of 2.5 Lit Falt Bottal , Coombs Ahg Sera 5Ml(Each),Consumable , Coombs Serum (Anti Human Globulin) (Polyvalent)(1X5=5 Ml),Consumable , Corrugated Drainage Sheet, Sterile, Multichannel, Single Use(2 Inch X 6 Inch (Pvc)-Piece),Consumable , Cotton Based Crape Bandage 10Cm X 4M (Box Of 10 Bandages) , Cotton Based Crape Bandage 15Cm X 4M (Box Of 10 Bandages) , Cotton Delivery Belt , Cover Slip With Isi Marked Size:18X18mm(+/- 1.00Mm),Thikness 0.13.. To 0.17Mm(Pkt Of 50 Pieces),Consumable , Cpap Machine , Cpk-Mb Kit (Kinetic) 25 Test/Kit , Cpk-Mb Kit (Kinetic) 25 Test/Kit , Creatinin Kit , Creatinine600 Ml(Model Ba 400 System),Consumable , Creatinine Calorimeter For Semi Auto Kinetic 4X60ml 480Test/Kit , Creatinine Kinetic Pack 2X50ml (Span/Tulip/Erba) , Cresent Knife(1 Each),Consumable , Crp (Hs)(100 Tests),Consumable , Crp Test Kit (Latex/Card) (25 Test/Kit) , Curved Scissors- Laparoscopic 5Mm Size, 360 Degree Rotating With Insulated Shaft, Non Ratchet , Plastic Grip(36 Cms Length, Monopolar Pin Provision For Usage With Electro Surgical Unit, Independently Moving Jaws),Consumable , Cushined Chair With Out Arm Size 865X410x450x500 Mm , Cushioned Chair With Arm Size 900X455x500x560 Mm , Cushioned Chair Without Arm Size 865X410x450x500 Mm , Cut Needle 48 Mm Stainless Steel Length(45 Cm Size 6),Needle 1/2 Ccs , Cvp Line Complete Set , Cvp Line Complete Set , Cyanemeth Solution For Hb 5 Litre , Cyanemeth Solution For Hb(Mfg By Beacon Diagnostic)(5 Lit Can),Consumable , Cylinder Brush , Cytochrome Stain With Buffer (500 Ml),Consumable [710030] , Cytoplasam Stain A&B Rapid Pap Pack Of 500Ml , D-Dimer(10X3 Ml),Consumable , D-Dimer(10X3 Ml),Consumable , Deaver Retractor Abdominal Central Oxygen Supply Complete Per Mtr , Dead Body Cover Standarad Quality , Defbrillator Biphasic, Features : Offers Variable Energy Level Selection, (2,3,5,7,10,20,30,50,70,100,150,200 Joules), Battery Capacity - 50 Shocks On Single Charge. Adult &Pediatric Paddles Support, Compact & Ligh Weight : Approx 5.0Kgs Max, Ecg Through Paddle , Dengurapid Test Card-Single Test , Dengu Card- Antigen(25 Card/Pkt),Consumable , Dengue Card Test 100 Test Kit , Dengue Card Test 100 Test Kit , Dental X-Ray Film Digital 1X150 , Dental X-Ray Film Size 31 X 41 Mm (150 Films / Pkt) , Desert Cooler 24” Exhaust Fan All Body Gi Sheet 22 Gauge , Desirepoly Bag Colour Sutable Forapprox 35Ltr Dustbeen , Desire Poly Bag Colour Sutable Forapprox 10Ltr Dustbeen , Desire Poly Bag Colour Sutable Forapprox 60Ltr Dustbeen , Desired Bio Hezard Poly Bag Capacity Of 30 Ltr , Desired Bio Hezard Poly Bag Capacity Of 50 Lit / 30 Lit. , Desired Bio Hezard Poly Bag Capacity Of 50 Ltr , Developer Powder (22.5 Ltr) For X-Ray , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life - (5 Ltr Can To Make 22.5 Liters Working Solution) , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life-2 Lit Can( To Make 9 Liters Working Solution) (Bromodex Mp Developer Concentrate) 9Ltr Packing , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life-3 Lit Can( To Make 13.5 Liters Working Solution) (Bromodex Mp Developer Concentrate) 13.5 Ltr Packing , Diagnostic Strips For Urine Sugar/Albmin Packing: 100 Strip/Pkt , Dialysis Starting Kit Disposable:A)Sterile Tray With Top(Disposable),Size Not Less Than 30X30cm B) Sterile Drape Size Not Less Than 45X45 Cm 1No C) Cotton Ball 6 No D)(D) Cotton Gauze Pieces 1,E) Artery Forceps-1 No (Disposable)),Consumable , Dialysis Starting Kit Disposable:A)Sterile Tray With Top(Disposable),Size Not Less Than 30X30cm B) Sterile Drape Size Not Less Than 45X45 Cm 1No C) Cotton Ball 6 No D)Cotton Gauze Pieces 1 , Diamond Marke Pencil , Digital Ball Watch Standard Company , Digital Thermometer , Digital Wrist Watch , Digital X Ray Film (Pack Of 100)),Film Size4 Inch X 17 Inch D , Digital X Ray Film -10X12 (150 Films/Pkt) , Digital X Ray Film -11X14 (150 Films/Pkt) , Digital X Ray Film -8X10 (150 Films/Pkt) , Digital X-Ray Film Size 14 X 17((100 Sheet Per Packet)),Film , Digital X Ray Film(Dihl(Pack Of 150)),Film 10 Inchx 12 Inch , Digital X-Ray Filimdigital X Ray Film(Dihl(Pack Of 150)),Size Of Film 8 Inch X 10 Inch , Digtital Thrmometer , Digtital Wrist Watch , Dim/.Wt. W215xh285xd150 Mm/2.85Kg Protable Pa Amplifier Systems Wa 320Dpr 20 Watts (Power Output 25 W Max Input – 2Xmic 2.5Mv,1Xaux 125Mv Tone Controls Bass + 4Db At 200 Hz, Treble+ 5Db At 10Khz Power Supply : Ac Mains, Dc 12V Car Battery,Dry Cells (8Xum-1) , Dimension W200xh240xd145mm , Dionised Water 5 Ltr Cane(Each),Consumable , Disinfectant Renaclean Cold Sterilant (5 Ltr Can) , Disinfectant Renasteril Hot Disinfectant (5 Ltr Can) , Disposable Appronpvcconsumable Full Size , Disposable Bed Sheet 60X90 , Disposable Cresent Knife(2.2Mm),Consumable , Disposable Cup For Urine-Sputum 30Ml 80 To 90 Mm Diameter 100/Pkt , Disposable Dust Mask - Jl246c Equivalent To N-95 Mask , Disposable Examination Gloves Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile Medium , Disposable Examination Gloves Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile Small , Disposable Examination Gloves Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile, Size:- Large , Disposable Keratom Knife(2.8Mm),Consumable , Disposable Keratom Knife(3.2Mm),Consumable , Disposable Needle, 24G Surgical Material , Disposable Needles 22Gconsumable , Disposable Needles 23 No , Disposable Needles 26G X 1/2Consumable , Disposable Paper Gloves Size 7 Inches Consumable , Disposable Paper Gloves Size 7,1/2 Inches Consumable , Disposable Pricking Lancet (Pkt Of 200 Units)(Packet),Consumable , Disposable Pricking Lancet 100 Unitsconsumable , Disposable Scalp Vein Set Size 20 No , Disposable Scalp Vein Set Size 22 No(Each),Consumable , Disposable Sharp Collection Containers 1.5 L , Disposable Sharp Collection Containers 5 Ltr , Disposable Sideport Knife(Num),Consumable , Disposable Spinal (L.P.) Needle(25G),Surgical Material , Disposable Spinal Needle 18 No. , Disposable Spinal Needle 22 No. , Disposable Spinal Needle 23 No. , Disposable Sterile Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 6 Inch / Pair(Pair),Surgical Material , Disposable Sterile Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 7 Inch / Pair , Disposable Sterile Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized6.5 Inch / Pair(Pair),Consumable , Disposable Sterile Gloves Bis Specification Gloves, Surgical Rubber,Made Of Hypoallergic Latex 100%,Electronically Tested Sterilize No 7Inch/Pair(Pair),Consumable , Disposable Sterile Gloves Isi Marked Surgical Rubber Hypoallergenic Latex 100% Powder Free 7 1/2 Inc , Disposable Sterile Gloves Isi Marked Surgical Rubber Latex 100% Powder Free 6 Inches , Disposable Sterile Gloves Isi Marked Surgical Rubber Made Of Hypoallergenic Latex 100% Powder Free 7 Inches , Disposable Sterile Hypodermic Syringe 10Ml(Each),Consumable , Disposable Suction Catheter Assorted Covering All Sizes 10,12,14,16,18Consumable , Disposable Surgeon Cap(Box Of 100 Caps) , Disposable Syringe (For Vitamin K Inj)(1Ml With Needle 26G),Consumable , Disposable Syringe With Needle(20Ml Each),Needle , Disposable Syringe With Needle(2Ml Each),Syrings , Disposable Syringe With Needle(3Ml Each),Syrings , Disposable Syringe With Needle(5Ml Each),Needle , Disposable Three Layer Surgical Mask(Box Of 100 Mask) , Distilled Water (1X5 Lit),Consumable , Dialyzers Multiple Use Made Of Polysulphone Or Polyethersulfone Low/Middle Flux, Hi Performance Dialyser Performance Enhanced Technology With Hi Biocompatibility Housed In Medical Grade Polycarbonate Openable Ends For Easy Cleaning Caps(For Dialysate Inlet Utlet For Safer Storage Openable Caps(Red And Blue)Hi Quality Sterilisation Procedure Using Gamma Radiation And Should Meetings Standards Of European Ce/Iso13485:2003Sterlised),Consumable , Dj Stent For Ureter 6 Fr , Dj Stent For Ureter 8 Fr , Dm Water Pack Of 5 Litt Can , Domestic Hut 8.5 X 6 X 13 , Domestic Hut 8.5 X 6 X 13 , Door Matte Big Size Jooth (Sandard Quality) , Door Matte Big Size Plastic (Sandard Quality) , Door Matte Medium Jooth (Sandard Quality) , Door Matte Medium Plastic (Sandard Quality) , Double Blood Bag 450 Ml Cpda(Each),Consumable , Double Lumen Hoemodialysis Catheter With Pur Ext Tube , Double Lumen Polyurethane Cvp Catheter 4 To 5 Fr(Length 8 To 13 Cm, Each),Consumable , Dpx(1 X 250 Lit),Consumable , Dpx(1 X 250 Lit),Consumable , Drabkin Solution For Hb (1X5 Lit),Consumable , Drabkin Solution For Hb (1X5 Lit),Consumable , Draw Sheet Bleach 45 X 45 , Dressing Drum (Made Of Ss) (Size:-11X9) Standard Qualtiy , Dressing Drum (Made Of Ss) (Size:-9X9) Standard Qualtiy , Dressing Drum Ss Size 11X15 Standard Qualtiy , Dressing Drum Ss Size 6X6 Standard Qualtiy , Dressing Drum Ss Size 9X11 Standard Qualtiy , Dressing Trolley - Frame Work Made Of 1 Vertical M.S Pipe , Two S.S Shelves Over With S.S Railling On All Four Sides , The Trolley Fitted S.S Bucket And Bowl And Mounted On 4 Dia Castors.Over All Size 30Lx18Wx32H, Finish Pre Treated And Epoxy Powder Coated, Also Available In Complete S.S , Drop Bottle Plastic 500Ml , Droper 2Ml , Dura Patch (G.Patch)(10X12),Consumable , Dura Patch (G.Patch)(8X10),Consumable , Dustbin Foot Operated Plastic, Size 10Ltr, Isi Mark , Dustbin Without Foot Operated ,Size 5 Ltr,.Isi Mark , Dusting Powder, 10 Gm ( Neomycin Sulphate 5 Mg, Baccitracin 250 Unit, Sulphacetamide Sodium 60 Mg) , E.D.T.A. Vacunater With Needle(3 Ml),Consumable , Ea- 50 (Modified) (For Cytology)(1X125 Ml),Consumable , Ecg Paper (Chemical Coated)(80Mmx 20 Mtr Each),Consumable , Ecg Paper(Chemical Coated) 50Mm X 30 Mtr. Roll , Ecg Paper(Wax Coated) (50Mm X 30 Mtr, Roll),Consumable , Ecg Paper(Wax Coated) Heavy Quality 50Mm X 30 Mtr/ Roll , Economical & Compact , Edta K3 Vial Each , Edta Powder(250 Gm),Consumable , Edta Solutions K3 (150 Ml) , Edta Solutions K3 (500 Ml) , Edta Vial With Safty Cap (2Ml.) Capsule , Edta Vial With Safty Cap (2Ml.) Capsule , Ehrilichs Aidehyde Reagen (2X250 Ml),Consumable , Ehrilichs Aidehyde Reagen (2X250 Ml),Consumable , Electolyte Analyzer 3 P-Ise Based Technology Easy Selection Through Fuction Icon Of Key 100 Result Memory And Quality Contorol Option , Electric Geyser 10 Ltr Capacity Isi Marked , Electric Geyser 15 Ltr Capacity Isi Marked , Electric Led Troch Chargable , Electrolyte Solution A 250 Ml (250Ml) , Electrolyte Solution A 250Ml(250Ml),Consumable , Electronic Baby Weighing Machine Capacity 20Kg Resolution : 10 Gm Pan/Platform : 550Mmx300mm (Min) , Elisa Reader - 0.000-3.5 Abs Mesurent Range, 500 Test Programe & 10000 Result Store, Bichromatic Optic System With Plate Shaker, External Mouse For Easy Handing Large Touch Screen, Whole Plate Reading In Just 5 Sec , Elisa Reader & Washer Printer , Elisa Washer - 48 User Programmable Wash Protocoles, 8 Way/12 Way Manifold, Auto Calibration, Washes Flat Round & V-Bottom Well, Well Depth Detection , Emergency Cart , Emergency Drug Trolley/Crash Cart , Emergency Light Big Size , Empty Bottel 500Ml With Cap , Empty Bottle Droping 150 Ml , Endotracheal Tube Internal With Radioopaque Line(Dia 2.5 Mm To 5 Mm, Each),Consumable , Endotracheal Tube No 5.5(Uncuffed),Each , Endotracheal Tube No 6.0(Uncuffed),Each , Endotracheal Tube, Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Standard 15 Mm Connector Sterile, Single Use Curved Shaped Blister Pack-Suiting The Shape Of Product(Size 4 , Each),Tube , Endotracheal Tube,Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Standard 15 Mm Connector Sterile, Single Use Curved Shaped Blister Pack-Suiting The Shape Of Product(Size 3),Tube , Endotracheal Tubes Size 7 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each),Consumable , Endotracheal Tubes Size 8 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each),Consumable , Endotracheal Tubes Size 9 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each),Consumable , Endotreheal Tube Size 4 Cuffed -Piece, Should Have Silicon Tube With Radio Opaque Blue Line , Enema 100 Ml (Sodium Acid Phosphate 10 Gm, Sodium Phosphate 8 Gm / 100 Ml) , Enema Appratus 1000 Ml Stainless Steel And Rubber Connection Tube Standard Qualtiy , Environmental Desontamintation System , Eosin 2% Solution (1X250 Ml),Consumable , Esbachs Reagent (125 Ml),Consumable , Ethanol (Abosolute Alcohol 99.9% (500Ml) , Eye Drape Disposable Towel (Size-70*70Cm Area 08*08),Consumable , Face Shield Protector Safaqi( ),Consumable , Factor Ix Deficient Plasma (Less Than 1%)(10X1 Ml),Consumable , Factor Vii Deficient Plasma ( Less Than 1%)(10X30 Ml),Consumable , Falcon Tube Plastic Contianers With Air Tight Cap , Fauchets Reagents (125 Ml),Consumable , Fdp Kit(4 Ml),Consumable , Feeding Tube (Catheter)(10 G, Each),Consumable , Female Reprodective System Complete , Femoral Catheters Single Lumen Set Adult(Size - 6F To 8F, Length 13 Cm To 15 Cm, Each),Consumable , Femoral Catheters Single Lumen Set Pediatric(Size - 3F To 4F, Length 13 Cm To 15 Cm Or Less),Consumable , Femoral Catheters Single Lumen Size Adult (Set Of 12 Different Sizes), Set , Femoral Catheters Single Lumen Size Size Pediatrics((Set Of 12 Different Sizes), Set),Consumable , Field Stain A 500Ml [5410005] , Field Stain B 500Ml [5410023] , Filter For Complete Pulmonary Function Testing (Including Dlco) With Body Box(100 Filters Per Pack, Consumable , Filter For Complete Pulmonary Function Testing (Including Dlco) With Body Box(100 Filters Per Pack, Make- Medisoft Sa),Consumable , Filter Paper No.1 Whatman , Filter Paper Sheet((Whatmann No 01) Pack Of 100 Sheets , Finish- Pre Treated And Epoxy Powder Coated , Finite Pump , Finite Pump , Fire Exjesting Cylander Abcd Type 5 Kg Complete , Fire Exjesting Cylander Refling For 5 Kg , Fistula 16G, Single Sterilizedsingle Needle Packing , Fistula 17G, Single Sterilizedsingle Needle Packing , Fistula Sterilized Twin Needle(16 G (Two Needle Pack)),Consumable , Fixer Powder (Bromex Acid Fixer With Hardner) ( 22.5 Ltr/Pkt) , Fixer: It Shall Be Powder Fixer To Produce Clean Radiographs Available In Pack Size Size:- 13.5 Ltr , Fixer: It Shall Be Powder Fixer To Produce Clean Radiographs Available In Pack Size Size:- 9 Ltr , Flask Glass Flat Bottam 1000Ml , Flask Glass Flat Bottam 500Ml , Flask Pyrex 500Ml , Flask White Glass Borosil 1000Ml , Flask White Glass Borosil 500Mg , Floor Cleaning 1000 Ml Isi Mark , Floor Cleaning Liquid Cleaning 5 Lit , Floride Vial With Sp Pack Of 100 , Flouride Solution (Pot.Oxalate 5% Flouride 1%) Pack Of 150Ml , Flow Regulator (Dial Flow)(Each),Consumable , Foetal Stethoscope Of Sk Sheal , Foldable Iol Sterile Lens Pc+14D(Lens-2),Pc+16D(Lens-3),Pc+18D(Lens-5),Pc+19D(Lens- 5),Pc+19.5D(Lens-5),Pc+20D(Lens-15),Pc+20.5(Lens-15),Pc+21D(Lens-13),Pc+21.5D(Lens- 11),Pc+22D(Lens-11),Pc+22.5D(Lens-5),Pc+23D(Lens-5),Pc+24D(Lens-3),Pc+26D(Lens-2)(100 Lens Per Box),Lens , Foleys Catheter Size 12-2 Way Consumable , Foleys Catheter Size 14-2 Way , Foleys Catheter Size 14-3 Way , Foleys Catheter Size 16-2 Way(11 Each),Consumable , Foleys Catheter Size 18- 2 Way , Foleys Catheter Size 20-2 Way(12 Each),Consumable , Foleys Catheter Size 22-2 Way(13 Each),Consumable , Foleys Catheter Size 24-2 Way(14 Each),Consumable , Foleys Urinary Catheter 2 Way Size 8 , Foleys Urinary Catheter 3 Way Size 16 , Foleys Urinary Catheter 3 Way Size 18 , Foleys Urinary Catheter 3 Way Size 20 , Foleys Urinary Catheter 3 Way Size 22 , Foleys Urinary Catheter Pediatrics Size 10 , Foleys Urinary Catheter Silkolatex 2 Way Sterile, Non Toxic Size 10 , Foleys Urinary Catheter Silkolatex 2 Way Sterile, Non Toxic Size 10 , Foleys Urinary Catheter Size 16 2 Way , Foleys Urinary Catheter(3 Way Size 12),Surgical Material , Foot Operated Sanitizer , Foot Sanitizer , Foot Step Double Steel Iron Standard Qualtiy , Forcepartery Sp Wells Cvd. 20 Cm/8” Standard Qualtiy , Forcepkocher Artery Cvd 8 “ Standard Qualtiy , Forcepkocher Artery Str 8 “ Standard Qualtiy , Forcep Allis Tissue 4 ?5Th20 Cm/8” Standard Qualtiy , Forcep Artery Mosquito Cvd 12.5Cm/5” Standard Qualtiy , Forcep Artery Sp Wells Cvd. 15 Cm/6” Standard Qualtiy , Forcep Dis Sectionplain Ss 17.5 Cm Standard Qualtiy , Forcep Dis Section Plain Ss 20 Cm Standard Qualtiy , Forcep Hysterectomystandard Qualtiy , Forcep Intestinalsize 16 Cm Standard Qualtiy , Forcep Intestinal Size 12.5 Cm Standard Qualtiy , Forcep Mousquito Str+Cvdsize: 12.5 Cm , Forceps Teeth Size 12.5 For Dressings.Steel , Forcepsplain Size 10 For Dressing S.Steel , Forcepsplain Size 12.5 For Dressings.Steel , Forcepsplain Size 17.5 For Dressings.Steel , Forcepsplain Size 25For Dressings.Steel , Forcepsteeth Size 10 For Dressings.Steel , Forcepsteeth Size 15 For Dressings.Steel , Forcepsteeth Size 25 For Dressings.Steel Standard Quality , Forceps Plain Size 15 For Dressings.Steel , Forceps Plain Size 20For Dressings.Steel , Forceps Teeth Size 17.5 For Dressing S.Steel , Forceps Teeth Size 20 For Dressings.Steel , Formaldehyde (Formalin)34% Acq 450 Ml Bottle , Formaldehyde 40% (Conc. Formaline)(1 X 30 Lit),Consumable , Formalin Chamber Internal Trays Sterdization Size 21X8X8.5Standard Quality , Formoline Solution 450Ml , Fouchets Reagent (100 Ml Bottle) , Fram Work Made Of Aluminum Tubes , Freedge 165 Litre , Freedge 220 Litre , Freq Resp.100-10 00Hz + 3Db , Full Bio Chemistry Analizer -200 Test/Hour, Staff Function, 60 Sample Positin With Refrigeration , On Board Wash Saction , 8 Interference Filters And 2 Position For Aptional, Photometric Range 0-3 Abs , Funnel , Funnel , G6pd Deficiency Test Kit - 10 Test , G-6Pdh (Quantitative Uv Kinetic (Liquistat Pack Of 15X1.1Ml (Span/ Tulip/ Erba) , Gauze Swab/Pad 4 Layer 10Cmx10cm , Gauze Swab/Pad 6 Layer 10 Cmx 10 Cm , Gauze Swab/Pad 6 Layer 20 Cmx 20Cm , Gentian Violet (Gram Stain) 100Ml Bottle , Giemsa Stain (Merck / Span) (125 Ml),Consumable , Glacial Acetic Acid (2.5 Liter),Consumable , Glass Beaker Cap.1000Ml , Glass Beaker Cap.500Ml , Glass Rod Size 12 Inch. , Glass Slide 75Mm X 25Mm 1.1 Mm [6120086] , Glass Slide 75Mm X 25Mm 1.35 Mm [987700] , Glass Slide With Isi Mark-At Least 75Mm X 25 Mm- Thickness At Least 1.1Mm,Detail Specifications-I-With Smooth Edges, Without Any Scrathtches. Ii-Glazed Glass.Iii-No Visual Or Chromatic Abbretions(50 Slides/Packet),Consumable , Glass Test Tube 12 X 100 (Medium Size) Heavy Quality 100/Pkt , Glass Test Tube 12 X 75(Small Size) Heavy Quality 100/Pkt , Glass Test Tube 5 Without Edge [987879] , Gloter Aldhiygde Solution Packge 1 Ltr , Gloves Latex Autoclavable 8 No (Pair) Made Of Natural Latex Micro Rough Finish For Better Grip , Gloy Size Board , Glucometer , Glucometer Cell , Glucometer Sprips (1X100) , Glucometer Strip (1X100) , Glucometer Strips 1 Should Be Able To Use Capillary Blood Samples 2 Should Have Expiry As Printed On The Label Of The Supplied Box(3 All Strips Should Have At Least One Year Expiry Date From The Date Of Supply 1 Glucometer Free With Each 1 Thousand Strips Rate Should Be Quoted For ,Consumable , Glucose600 Ml(Model Ba 400 System Consumable , Glucose Kit (God/Pod)(350Ml),Digonstic , Glutaraldehyde Solution 2% In 5 Litre Can (2 Strips/Vials Per Each Can)(5 Litre Can),Consumable [700591] , Gold Chloride (1X1 Gm),Consumable [710056] , Goods Carrying Vehicle. (Size 48X24X24) Four Wheeler , Gpt (Ast) Kinetic (Liquistat) Pack Of 10X10ml , Gram Iodine (Gram Stain) (100Ml Bottle)(Bottle),Consumable , Gram Iodine (Gram Stain) 125 Ml , Gram Staining Kit (Crystal)(125Ml X 4),Consumable , Grasper- Laparoscopic 5Mm Straight 360 Degree Rotating With Insulated Shaft, Toothed A Traumatic Grasper With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable [720068] , Gynec Sheet 80 X 48 Standard Pvc Quality , Gypsona 4” , Gypsona 6” , Haby Gum Boot , Haematoxyline Solution (Harris)(1X125 Ml),Consumable , Haemoglobi Pippate(Pippate),Consumable , Haemoglobin Tube(Tube),Consumable , Haemoglobino Meter (Sahilmathard) , Half Volume Pt And Aptt Testing , Hand Sanitizer With Pump(500Ml),Bottle , Hand Wash Liquid Cleaning Standard Company , Handpiece(Blue),Consumable , Handpiece(Transducer),Each , Hb Colour Scal Book , Hb Electrophoresis(200 Test),Consumable , Hba 1 C (Glycosylated Hb)(100 Tests),Consumable , Hba Ag Elisa 96 Kit 1X96(Each),Consumable , Hba Ag Rapid Card Test(Each),Consumable , Hbnc Kit Complete - , Hbs Antigeng Kit Card(Pack Of 10 Card Test With 10 Dropper, 1 Buffer Solution, 10 Pricking Lancet And 10 Alcohol Swab),Digonstic , Hbsaganigine Kit Card(Pack Of 10 Card Test With 10 Dropper, 1 Buffer Solution 10 Pricking Lancet And 10 Alcohol Swab) J Mitra/ Span/ Tulip , Hbv Elisa Test Kit Pack Size : 96 Wells Per Kit(Rate Should Be Quoted For 1Kit Containing 96 Wells),Consumable , Hbv Rapid Test Kit Quantity Is In No. Of Test Card Only(And Rate Should Be Quoted For One Test Card),Consumable , Hcl N/10 (500 Ml Bottle) , Hcv Kit Card Test(25 Test / Kit),Digonstic , Hcv Rapid Test Card Single Test (J Mitra/ Span/ Tulip) , Hdl Kit 50 Test [987882] , Hdl Kit Ppt(2X50ml 200 Test/Kit),Consumable [987760] , Hdl/Ldl Standard(1X1 Ml),Consumable [710063] , Hdpe Jar 5 Litt With Cap , Heamstrips (Oc , Hematology Cell Counter Reagents Dilutent (20 Ltr) , Hematology Cell Counter Reagents Rinse Solution (20 Ltr) , Hemoostasi Analyzer , Hemotocyto Meter,Consumable , Hiv 1&2 Test Cards , Hiv 1+2 (Rapid) Per Card (J Mitra/ Span/Tulip) , Hiv 1+2 (Rapid) Per Card J Mitra , Hiv Rapid Test Card Single Test (J Mitra/ Span/ Tulip) , Hospital Bed Ss With Mattress , Hot Air Oven 14X14X14 , Hot Water Bagstandard Company , House Hold Referigerator Double Door Isi 265 Litt , Hub Cutter- Non Electric Lockable Safety Portable Box For Disposal Of Hypodemic Needles.Consumable , Human Albumin 20%(50 Ml Vial Ffs Glass Bottle),Bottle , Hydrochlorid Acid(Hcl) N/10 (500 Ml Bottle) , Hydrogen Peroxide (Conc.) H2o2 (500 Ml),Consumable , I.V Stand 4 Legs Base , I.V. Cannula With Injection Valve(Size 24 G),Consumable , Ice Gel Pack (200&500Gm) , Id Wrist Band(Identification For Mother/Child Specific Colour)(Wrist Band/No),Consumable , Immersion Oil (Refractive Index Of 1.48. It Should Be Colourless,Odourless, Transparent, Free From Fluorescence In Day Light With Realtive Density Of 0.827 To 0.890, Visosity Of 110To Gravity Of 76-0.78 At 15.5 C , Immersion Oil Lens (All Type) , Incubater B.O.D , Incubator , Incubator Digital Microbiological , Indicator Sol, For Ph (Litmus Sol) (1X500 Ml = 500 Ml),Consumable , Infant Feeding Tube (Catheter) Size: 3G , Infant Feeding Tube (Catheter) Size: 4G , Infant Feeding Tube (Catheter) Size: 8G(Each),Consumable , Infant Feeding Tube Size: 5G , Infant Feeding Tube Size: 6G , Infant Feeding Tube(10 G Each Piece, Each),Consumable , Infant Feeding Tube(7G Each Piece, Each),Consumable , Infant Mucus Extractor Sterile Pvc(Each),Surgical Material , Infant Weing Scal With Bag , Infantometer , Infusion Pump Features :- Front Load Of Yringe , Automatic Detection Of Syring, Bolus And Purge Facilty , Self Illutrative Contorl Panel , Syring Capacity , 10Ml-300Ml/Hr.20Ml-500Ml/Hr , Input – Mic-1:3Mv, Mic-2:3Mv, Aux: 100Mv 800Mv Rec. Output 800Mv Tone Controls Bass : + 6Db At 80Hz, Treble :+ 6Db At 8Khz Power Req. 220-240V Ac 50/60Hz, 12V Car Battery 12V.3.5Ah Rechargeable Battery Dim/.Wt. W215xh285xd150 Mm/4.65Kg , Input Channels : Built –In Microphone , Instrument Tray Ss With Cover 10X8 Standard Company , Instrument Tray Ss With Cover 15X12 Standard Company , Instrument Trays With Cover Ss Size: 10 X 12 Standard Company , Instrument Trays With Cover Ss Size: 7 X 11 Standard Company , Instrument Wash 500Ml With Spray Pump , Insulated Container , Insulin Syringe(Each),Consumable , Intra Venous Set (Adult) With Airway And Needle Standard Company , Intra Venous Set (Child) With Airway And Needle Standard Company , Intracath Cannula For Single Use (Intravascular Catheters) Bis(Gauze 22, Length 25),Consumable , Inverter Battery 500 Watt 150 Ah Isi Mark , Inverter With Battery 1000 Va [One Battery Required]Isi Mark Standard Companywith Installation , Inverter With Battery 1500 Va [Two Battery Required]Isi Mark Standard Companywith Installation , Invertor Batteryisi Mark 150 Vah , Iol - Made By Repated Company, Eto Sterlized, Powernon Foldable Iol Sterile Lens Pc+14D (2), Pc+16D (3) Pc+18D (5), Pc+19.5D (5), Pc+20D (15), Pc+20.5D(15), Pc+21D (13), Pc+21.5D (10), Pc+22D (10), Pc+22.5D (5), Pc+23D(5), Pc+24D(3), Pc+26D (2), Ac+19D (2) (No), Single Price(Standard Company) , Iron Bed Size 5X2.6 , Iron Box 5’X2.5’X2.5’’ , Iron Box 6’X3’X3’’ , Iron Stand With Belding Work , Isoflurane(250 Ml Amber Color Bottle),Inhalation , Isopropyl Alcohol (Propanol)(1 X 2.5 Lit),Consumable , Iv Cannula Size With Inj.Valve (Port)(18G ), Consumable , Iv Cannula Size With Inj.Valve (Port)(22G ), Consumable , Iv Cannula With Inj Valve(18G),Consumable , Iv Cannula With Inj Valve(20G),Consumable , K Wire(Length 375Mm Size:1.6Mm Roll),Consumable , K Wire(Length 375Mm Size:1.8Mm Roll),Consumable , K3 Blood Vaccutainer Edta-100 Tubes/Pkt , Keratome 3.2 Keratome Round Stock 3.2Mm Full Handle Knives E.T.O. Sterile Angled Bevel Up 45 Deg( ),Consumable , Knife Blade All No Pack Of 100 , Kit For Total Protein (Including Albumin And Total Protein) 100Ml Bottle , Lab Coat , Labour Room Tray 12”X10” , Labour Room Tray 15”X12” , Labour Table 3 Fold Ss With Foam Mattress, , Labour Table Manul , L-Alanyl L-Glutamine Solution For Infusion (20%W/V)(Each),Consumable , Larrynoscope Set With Four Blades (Adult) , Larrynoscope Set With Four Blades (Infant) , Larrynoscope Set With Four Blades (Paediatric) , Latex Based Baloon Capacity (30-50Ml) Foleys Catheter(Size 14-3 Way),Consumable , Latex Based Baloon Capacity (30-50Ml) Foleys Catheter(Size 16- 2 Way Each),Consumable , Latex Based Baloon Capacity (30-50Ml) Foleys Catheter(Size 18- 2 Way, Each),Consumabl , Latex Based Baloon Capacity (3Ml) Foleys Urinary Catheter Peadiatrics(2 Way Size 8, Each),Consumable , Latex Based Baloon Capacity (3Ml) Foleys Urinary Catheter Peadiatrics(Size 10 , Each),Consumable , Latex Examination Gloves (Large) (100/Pkt)(Packet),Consumable , Latex Examination Gloves (Small) (100/Pkt)(Packet),Consumable , Latex Examination Gloves(Medium),Consumable , Lcd Projecter , Ldh Kit Pack (50 Ml Bottle),Consumable [700603] , Lead Letter 0-9 Sets (100 Clips/Pkt) , Leishman Stain (500 Ml Bottle),Consumable , Leishmann Stain Sol With Buffer Tablet Ph (1X5 Lit),Consumable , Lens Cleaning Paper , Lenstip(1 Each),Consumable , Lenstip(1 Each),Consumable , Life Boy Soap , Life Boy Soap 100Gm , Light Weight Composite Mesh : Polypropylene Andpolyglycolic Acid Partially Absorbable Composite Mesh With Large Pore Size 6 X 11 Cm , Liquid Hand Wash , Liquid Hand Wash Solution With Dispenser Consumable(500 Ml),Consumable , Liquid Paraffin 50Ml(Bottle ),Consumable , Liquid Senitzed (Hand Antiseptic) , Liquor Ammonia (500 Ml),Consumable , Long Body Suit -Non Woven Fabrie , Long Line Silicon Catheter, G-24, Fr-2, L-30Cm , Low-Profile Titenium Chemo Port With Cilicon Catheter (9.6 Fr, 6.6Fr, 3.9Fr,) Length -60Cm,Guide Wire, Peel-Away Desilet,Hubsite Needle(22G*20Mm) , Lugols Iodine Pack Of 100Ml , M-30-D-Diluent(20Ltr),Consumable , M-30-R-Rinse(20Ltr),Consumable , Macconckeys Agar(500Grm),Consumable , Macconckeys Agar(500Grm),Consumable , Mackintosh Double Colour Water Proof Rubber Marked Isi Hospital Rubber Sheeting Is:4135-1974 Packing And Making : As Per Clause No 4.1 And 4.3 / Mtr , Macro Porous Tissue Separating Multi Layered Partially Absorbablemesh With Oxidized Regenerated Cellulose, Polydioxanone And Soft Polypropylene Mesh(Size 15 Cm X 15 Cm),Consumable , Macro Porous Tissue Separating Multi Layered Partially Absorbablemesh With Oxidized Regenerated Cellulose, Polydioxanone And Soft Polypropylene Mesh(Size 15 Cm X 20 Cm),Consumabl , Malaria Antigen Pv/Pf Single Test , Malaria Rapid Stain Kit (Jsb I&Ii) One Minute Stain For Blood Parasite) Pack Of 2X500ml , Male Reprodective System Complete Standard Company , Malleable Splirls (X-Ray Through The Splints Fixing Of Splint Is By Zipper Or Belt Distal End Left Open To Expose Toes Should Be Washable And Reusable) , Mammanatallie Standard Company , Manometer And Flo Meter For Oxygen Cylinder , Maryland Dissector- Laparoscopic 5Mm Curved Maryland Dissector With Tapering End, 360 Degree Rotating With Insulated Shaft, Non Ratchet , Plastic Grip(36 Cms Length, Monopolar Pin Provision For Usage With Electro Surgical Unit, Independently Moving),Consumable , Masson Trichrome Staining Kits(100 Test),Consumable , Match Box , Mattres Cover Complete Size L.6.5Fxw3.5Fxt5.5F Inch , Mattress Coir With Foam Topping Plain Cloth Cover Size 72X36x4 Thik With Ragzine Cover , Medical Nitrous Oxide Gas In Jambo Size Cylinder(D Type),Miscellaneous , Medical Nitrous Oxide Gas In Medium Size Cylinder(B Type),Miscellaneous , Medical Nitrous Oxide Gas In Small Size Cylinder(A Type),Miscellaneous , Medical Oxygensteel /Aluminium Cylinder (10 Litres Water Cap) With Gas Specific Pin System(10 Liters),Inhalation , Medical Oxygen Gas Ip In Jambo Size Cylinder(D Type),Miscellaneous , Medical Oxygen Gas Ip In Medium Size Cylinder(B Type),Miscellaneous , Medical Oxygen Gas Ip In Small Size Cylinder(A Type),Miscellaneous , Medical X-Ray Film-Polyester Based Imaging Film 30.5 Cm X 30.5Cm (12X12) Size:- 50 Sheets In One Packet , Medical X-Ray Film-Polyester Based Imaging Film 35.6 Cm X 43.2Cm (14X17) Size:- 50 Sheets In One Packe , Medical X-Ray Film-Polyester Based Imaging Film 35.6Cm X 35.6Cm (14X14) Size:- 50 Sheets In One Packet , Medigard Hand Scrub [987893] , Messuring Cylinder 1Ltr With Spout , Mesuring Cylinder Pack Of 100Ml , Mesuring Cylinder Pack Of 1Lit With Spout , Mesuring Cylinder Pack Of 500Ml , Methanol(Acetone Free) For Leishman Staining (1X2.5Lit) , Methanol Pack Of 5Ltr , Methylaled Spirit , Methylate Spirit (Sep.Chemical Name Ethanol Denatured+5% Isopropyl Alcohol+5%Methanol, Molecular Structure : C2h50h Molecular Wt: 46.07 Purity : 90% , Methylene Blue 25Gm Dye Content 82% , Methylene Blue Pack Of 500Ml/Gram (Dye Content+42% Sepc.Chemical Name: Methylthionine Chloride, Chemical Structure: C16h18c1n3s,Molecular Wt: 319.9, Dye Content: Approx 82% (Should Be Available On The Container) , Metresses 3X6 With Raxine Cover 4 Densit , Micro Drip Set , Micro Pipet 1000 Fix And Variable Each , Micro Tips Big Pack Of 1000 Pices , Micro Tips Big Pack Of 500 Pices , Micro Volume Drip Set , Microalbumin Urine(100 Tests),Consumable , Micronthik Bag 10 Lit. , Micronthik Bag 30 Lit. , Micronthik Bag 5 Lit. , Micronthik Bag 50 Lit. , Micropiptte 100-1000 , Microscope With Digital Display And Having Magnification , Microsurgery Speciality Gloves(Size 6.5),Lens , Microtips (2-200 Ul) 1X1000(Each),Consumable , Milkiwhitegel Based Sanitizer1.Ethinol (Cas-64-17-5) 58-62% 2. Benzoil Coline Chloride 0.52% 1 % 3. Ph Neutral Contact Time 15 Sec 4.(Pack Size L& 500 Ml With Dispensor),Consumable , Mindray Bc 5300, Auto Hematology Analyzer Part -5(M- 53Diluent),Consumable , Mindray Bc 5300, Auto Hematology Analyzer Part -5(M- 53Leo (Ii) Lyes),Consumable , Mindray Bc 5300, Auto Hematology Analyzer Part -5(M- 53Lh Lyes),Consumable , Mixed Oxidant Disinefction Genration System , Mixi Isi Mark , Mobile Operatinglight Single Dom , Mobile Operating Light Double Dom , Mobile Operating Light Four Dom , Mobile Operating Light Three Dom , Modular Automitic Blood Culture System , Mopping Pad , Motorcycle Pa Amplifier Set (Mpa-40S) (Spc. Power Output16 W Rms At 10% Thd/22W Rms Max, , Motorized Ot Table With Chair For Ophthalmology , Mtp Cannulas Standard Company , Mva Kit (Mannual Vaccum Aspiration Kit) , Mva Kit (Mannual Vaccum Aspiration Kit) Consumable , N-95 3M Disposable Raspirator(Without Valve Ffp2),Consumable , N-95 3M Inv Disposable Raspirator(With Valve Ffp2),Consumable , Nah2 Po4 (Anhydrous) Analar / Gr/Ar (1X500 Gm = 500Gm),Consumable , Nasal Catheters Child Size Disposable Nasal Prongs , Nebulization Mask - Kit (Pediatrics) , Nebulization Mask-Kit (Adult) , Nebulize Compressor. Piston Model, Fitted With Small Fan, Nices Less 60 Decible, Nebulizer Chamber Autoclave, Particle Size Between 0.5 To 5 Micron Suitable For Adult And Pediatric Patient. Resptrable Particle Above 60, Tor 300 Mg/Min , Needle And Syringe Destroyer Electrically Operated , Needle And Syringe Destroyer Manually Operated , Needle Holder Laparoscopic 5Mm Straight Reusable Needle Holder With Ratchet Mechanism With High Quality Tungsten Plated Jaws For Enhanced Needle Grip(36 Cms Metal Shaft),Consumable , Needle Hypodermic Size 23 G , Needle Hypodermic Size 24G , Needle Hypodermic0insulin (Metallic Non0sterile) Needle , Neomycin And Sulfacetamide Sprinkling Powder 5 Gm(Each),Consumable , Neonatal Infant Weighing Scal With Sling , Neonatal Urine Collector Bag 50 Ml , Neubauers Chamber(Each),Consumable , Nibp (Non Invasive Blood Pressure) Multi Channel Monitor) , Nitrous Oxide Cyilnder , Non -Contact Rapid Temperature Measurment System-Screen 2.8 Inch Tft Screen, Infrared Resolution Size 160X120, Frame Rate 9Hz, Temperature Measurment Range 30 Dig.C-45Dig.C, Accuracy + 0.5Dig.C, Distance 1M. Measuring , Storage - Take And Store Photos To Sd Card , Software Pc Analysis Software, Battery - Rechargeable 3.7V/5000Mah Lithium Battery. 22650 Single Cell, Battery Working Hrs- Up To 6Hrs.To Escort Your Continucous Work, Weather Proof, Nycocard Reader -Up To 2M, Tripod Mounting Hole 1/4 Inch, Hba1c, Microabumin, D-Dimer, C-Reactive Proteins , Non -Invasive Ventilaor (Sponteneous And Timed) , Non Tuch Thermo Meter , Nuclear Stain Rapid Pap Pack Of 500Ml , Nutrient Agar(500 Grm),Consumable , Nylon Suture Spatulated Micropoint Reverse Cutting Needle, Double Armed Suture Size 9-0(12 Foils/Pkt),Suture , Obsteric Labour Talbe Mechacally :- Sep- Frame Work Made Of Heavy Ms Crca Tubular Pipe.Stainless Steel Top In Two Section , Back Rest Section Adjustable On Retched System, Trendleburg Position Adjustable On Screw Mechanism By Handle. Supplied With Waste Collecting , S.S Bowl On S.S Bracket And I.V Rod , Height Adjustable A Pair Of Leg Holders With Straps, Complete With Self Locking Traction Handle I.V Rod , Overall Size 72 Lx27Wx30H Cms.Finish Pre Treated And Epoxy Powder Coated.Also Available In Complete S.S , Occult Blood Test Kit (Haem Test Kit) (1 X 100 Strips),Consumable , Og6 (For Cytology)(1X125 Ml),Consumable , Operating Microscope For Ent (Imported) , Ophthalmo Scope Direct , Ophthalmo Scope In Direct , Orthopaedic Speciality Gloves(Size 7),Consumable , Orthopaedic Speciality Gloves(Size 7),Consumable , Overall Size 48Lx24Wx24H , Oxalic Acid , Oxidisedcellulose Absorbable Hemostate( 2X3),Consumable , Oxidisedcellulose Absorbable Hemostate(2X14),Consumable , Oxidisedcellulose Absorbable Hemostate(4X8),Consumable , Oxidised Regenerated Cellulose Absorbable Hemostate(1X2),Consumable , Oxidised Regenerated Cellulose Absorbable Hemostate(2X4),Consumable , Oxidised Regenerated Cellulose Absorbable Hemostate(4*4),Consumable , Oxygen Conentrator , Oxygen Cylinder (It Should Be A Standard ‘J’ Type Molybdenum Steel Cylinder To Fill Medical Oxygen The Capacity Should Be Of 5000 To 6000 Liters (5To6m3) At A Pressure Of 1800-2000Ibs/Inch2, A Pressure Regulator Capable Of Reducing The Pressure To Appropriate Level To Run Either A Ventilator Or Provide Oxygen Therapy With A Flow Meter Should Be Provided , Oxygen Cylinder Flow Meter , Oxygen Cylinder Gauze-1 , Oxygen Cylinder Gauze-2 , Oxygen Cylinder Gawge Valum , Oxygen Cylinder Jumbo Size Complete Set , Oxygen Cylinder With Instrument Set For Oxygen Delivery B Type,Make-Everest Kanto Cylinder Limited;(Model- Everest;Country Of Origin-India),Consumable [75001] , Oxygen Cylinder With Instrument Set For Oxygen Delivery D Type,Make-Everest Kanto Cylinder Limited;(Model- Everest;Country Of Origin-India),Consumable [75002] , Oxygen Humidifier , Oxygen Inhelation Mddial Oxygen Steel Aluminium Cylinder 10 Ltr( ),Consumable , Oxygen Mask Adult (Standard Size) Standarad Company , Oxygen Mask Paediatric (Standard Size) Standarad Company , Oxygen Nasal Cannula(Neonatal),Consumable , Oxygen Nasal Canula (Neonatal) 7 White Colour Tubing And Threaded Nut(25 Pcs/Pkt),Consumable , P.P.T 1.5 Tu Tubercullin Vial 5 Ml , P.P.T 10 Tu Tubercullin Vial 5 Ml , P.P.T 2 Tu Tubercullin Vial 5 Ml , P.P.T 5 Tu Tubercullin Vial 5 Ml , Paediatric - Double Lumen Catheter Set 6.5 F - 8.5 Fr, 13Cm (Curved), Kit , Paediatric - Double Lumen Catheter Set 6.5 F - 8.5 Fr, 13Cm (Straight), Set , Paediatric Drip Set(Set),Digonstic , Paediatric Epidural Set(19G Needle, Metal Stylet,22G Catheter,0.22Micron Epidural Catheter Lor Syringe , Paper Adhesive Microporous Surgical Tape 3 Inch X 5 M / Roll (10 Roll/Pkt)(3 Inch X 5 M / Roll (10 Roll/Pkt)),Consumable , Paper Adhesive Plaster 1 X 9.0Mts , Paper Adhesive Plaster 1/2 X 9.0Mts , Paper Adhesive Plaster Microporous Surgical Tape 1 Inch X 9 M / Roll , Paper Adhesive Plaster Microporous Surgical Tape 2 Inch X 5M /Roll , Paper Adhesive Plaster Microporous Surgical Tape 4 Inch X 9 M / Roll , Paper Adhesive Plaster Microporous Surgical Tape 6 Inch X 10 M / Roll , Paper Adhesive Plaster Microporous Surgical Tape 6 Inch X 5M /Roll , Para Film Sealing Film (Parafilm 100Mm Widht, 58M Length, For Use Between 40 Dgree C To 50Dgree C , Paraffin Strips , Patch Buprenorphine(10Mcg),Consumable , Patch Buprenorphine(20Mcg),Consumable , Patented Ball Method Technology For Extermely Reproducible And Realiable Result , Patented Ball Method Technology For Extermely Reproducible And Realiable Result , Patient Bed Powder Coted Size 84Lx36Wx24H , Patient Gown Standard Size , Patient Stool , Paracaine Eye Drop , Pediatric Chamber Set 100 Ml , Peledi , Ph Meter Digital For Water , Phenol Crystal 500Ml Purity 99.5% , Phenyal 40% /Phanolic Solution 40% , Phenyl - As Per Schedule O (Grade 1) 10 Lt Jar(Isi Marked),Consumable , Phenyl 40% , Photo Therapi Unit Double Surface , Photo Therapi Unit Single Surface , Pipete Graduated 0.2Ml , Pipett Graduated 2.0 Ml To 10Ml , Pistol Grip Curved Coagulating Shears With Ergonomic Handle In The Following Shaft Lengths 23 Cm. Can Seal Blood Vessels Upto And Including(5Mm In Diameter),Consumable , Pistol Grip Curved Coagulating Shears With Ergonomic Handle In The(Folloeing Shaft Lengths 36 Cm Can Seal Blood Vessels Upto And Including 5 Mm In Diameter),Consumable , Plain Disposable Vial 3Ml(Each),Consumable , Plain Vial With Screw Cap (12X75),Consumable , Plain Vial With Screw Cap(12 X 75),Consumable , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr / Roll(Roll),Bandage , Plaster Of Paris Bandage Bp 10 Cm X 2.7 Mts/Roll Standard Company , Plaster Of Paris Bandage Bp 15 Cm X 2.7 Mts/Roll Standard Company , Plaster Of Paris Pack Of 5Kg , Plastic Bottle(300Ml),Consumab Empty With Cap , Plastic Bottle(500 Ml),Consumable Empty With Cap , Plastic Box 9X3.5’X3’’ , Plastic Box 9X6’X6’’ , Plastic Box Supirior Quality 10X7x4 , Plastic Box Supirior Quality 9X6x4 , Plastic Bucket Black 20 Ltr , Plastic Container With 2Lt Cap , Plastic Tanki 500 Ltr. For Water (3 Layerd, Standard Quality, Manu.By Reputed Company) , Plastic Thaila 18 Lengthx 16 Widex 8 Thickness , Platelet Dilution Fluid (100 Ml Bottle) [700193] , Poliglactinsuture1-90Cm (Vicryl) , Poliglactin Suture1-110Cm (Vicryl) , Poly Bag Black 16X18’’ , Poly Propylene Mono Filament Sterile Precut With 1/2 Cir Rb(Needle 30 Mm Length 70 Cm Non Absorbable Surgical Sutures Usp Size 1/0),Surgical Material , Polycarbonate Goggle- Material Plastic(Uv-Protection, Lens Thickness 1-2 Mm, Weight-40-50G),Consumable , Polyethylene High Pressure Extension Tube, Length - 100Cm , Polyethylene High Pressure Extension Tube, Length - 150Cm , Polyethylene High Pressure Extension Tube, Length - 200Cm , Polyglactin 30 Mm 1/2 Circle Round Body 90 Cm Size 1/0(12 Foils/ Pkt),Consumable , Polyglyconic Suture 110 Cm Vicryl No.2-0 Pack Of 12 Foils , Polyglyconic Suture 190 Cm Vicryl No.1 Pack Of 12 Foils , Polyglyconic Suture 190 Cm Vicryl No.1-0 Pack Of 12 Foils , Polypropylene Size - 1, (12 Foils/Pkt)(1/2 Cir Rb Needle 45 Mm, Length 90 Cm ),Needle , Polypropylene Size-2/0 (12 Foils/Pkt)(1/2 Cir Rb Needle 25Mm, Length 45 Cm),Needle , Polythine Whit Standard Quality(Weghting Capicty 500Gm To 20Kg) , Poocha Long Cloth Standar Size , Popete Stand Glass Large Size , Post Operative Bag With Window Size 100 Mm(1 Each),Consumable , Post Operative Bag With Window Size 70 Mm(1 Each),Consumable , Postmartem Gloves , Postmartem Set , Potassium Permanaganate , Powder Developer Suitable For Processing Medical X-Ray Films. One Developer Box Shall Contain Part A And Part B Which Are Mixed At The Time Of Preparation Of Solution Of Specific Capacity Size:- 13.5 Ltr , Powder Developer Suitable For Processing Medical X-Ray Films. One Developer Box Shall Contain Part A And Part B Which Are Mixed At The Time Of Preparation Of Solution Of Specific Capacity Size:- 9.0 Ltr , Ppe (Personal Protective Equipment)(Full Body Suit With Shoe Cover Free Size, Gloves, Face Sheeled, Goggle Consumable , Ppe Kit Consumable , Pregnancy Detection Kit Ce Marked/Isi Marked 30 Test/ Kit , Pregnancy Test Card For Urine Test Single Cared , Pregnancy Test Card(10 Card Pack,Consumable , Pregnancy Test Strips For Urine Pack Of 100 Strips , Pregnant Stage And Reprodective Dumy , Presure Cukker 05Lrt , Presure Cukker 07Rt , Presure Cukker 10Lrt , Prinking Needle Pack Of 100 Pices , Prinking Needle Pack Of 200 Pices , Procedure Table , Protable Pa Amplifier Systems Wa 620 Dpr 25 Watts (Power Output 25 W Max Input – Mic-1:3Mv, Mic- 2:3Mv, Aux: 100Mv 800Mv Rec. Output 800Mv Tone Controls Bass : + 6Db At 80Hz, Treble :+ 6Db At 8Khz Power Req. 220-240V Ac 50/60Hz, 12V Car Battery 12V.3.5Ah Rechargeable Battery , Protable Pa Amplifier Systems Wa 625Dpr 25 Watts (Power Output 25 W Max , Protection Suit And Gloves( ),Consumable , Protein (Total) 600 Ml(Model Ba 400 System Consumable , Protein Electrophorosis In Blood (Serum) ,Urine ,Csf(200 Test),Consumable , Protien& Albumine (Total) Biuret And Bcg , Protien (Urine) Ba 400 Biosystems Diagnostics Pvt Ltd(240 Ml),Consumable , Pt Kit (Time) (Ist 1.00 - 1.20)(2X4 Ml),Consumable , Ptah Staining Kits(100 Test),Consumable , Public Addressing System , Pulse Oximeter Finger Tip , Pulse Oximeter Table Top , Purified /Distilled Water- Laboratory Grade , Pyrethrum Extract 2%(25 Litre Drum) , Quick Diff Staining Kits For Pap Smear(100 Test),Consumable , Ra Factor 50 Test Kit Qualicative [987764] , Rapid Ra 25 Test , Rbc Dialuation Fluid (500 Ml Bottle),Consumable , Reaction Rotor 10 Pc(Model Ba 400 System Consumable , Reagent Bottel Glass 5Lit , Reagent For Hdl Cholestrol Test(100 Ml (4 X 25)),Consumable , Refling Oxygen Cylande Jumbo Large , Refling Oxygen Cylander Medium , Refling Oxygen Cylander Small A Type , Refrigerant Compressor (Copeland Usa Maneurop ) , Refrigeratedwater Bath , Refrigerated Chillers With Cooling Tank System (2 Tr, Air Cooled Water Chiller) , Reseant Bottle 1000Ml Empty , Reseant Bottle 500Ml Empty , Resusciatation Set With Infant & Neonatal Mask , Retinoscope , Revolving Computer Chair , Revolving Stool 4 Leg , Ria Vail 12X75mm Pack Of 100 , Rib Belt Large(Mfg By - Precious Life Care),Each , Rib Belt Medium(Mfg By - Precious Life Care),Each , Rib Belt Small(Mfg By - Precious Life Care),Each , Rna Extraction Kit - Icmr Certified Kit(250 Test),Consumable , Rolled Bandage 7.5Cm Ͻ 5M , Rolled Bandaze 10 Cm X 5 Mtr. , Rolled Bandaze 15 Cm X 5 Mtr. , Rolled Bandaze 5 Cm X 5 Mtr. , Rolled Bandaze 7.5 Cm X 5 Mtr. , Room Coolersize-21X19X36Isi Mark 16 Fan & Pump With Gi Sheet Body , Room Heater Hot Air Blower 2 Kw , Rpr Rapid Card Test Kit (50 Test/Pkt) , Rpr Test Kit(100 Test),Kit , Rpr Test Kit(100 Test),Kit , Rubber Bands All Assorted Sizes , Ryles Tube (Pvc) Size : Adult16-18 ) , Ryles Tube (Pvc) Size : Children: 10-12 , Ryles Tube(Size 14 Each Piece),Consumable , S Direct Billirubin(1000 Ml),Consumable , Salt Testing Kit(As Per Attached Specification , Kit),Consumable , Sanitary Napkins ,Consumable , Scessior Stainless Steel 8: , Scessior Stainless Steel 9: , Schiotz Tonometer , Schirmer Strip For Ophthalmic Use , Scissor Dressing Str/Cur Ss 12.5 Cm , Scissor Dressing Str/Cur Ss 15 Cm , Scissor Dressing Str/Cur Ss 17.5 Cm , Scissor Mayo Str/Cur Ss 16 Cm , Scissor With Round Trap , Scissors Mayo Fine. Cvs 16.5 Cm/6.5” , Scissors Mayo Fine. Str 16.5 Cm/6.5” , Scissors Str + Cvd Size 10 Cm Cutical , Seenk Jhadoo (Standard Size) , Self Adhesive Drainable Stoma Bag For Colostomy & Illeostomyâ - Double Layered Self Adhesive With Flex Patern, Transparent Drainable Stoma Bag With Built In Filter And Velcro Outlet(Size 76 Mm),Consumable 1-Pc , Seman Diluting Fluid 100 Ml. , Semi Auto Analyzer Ce Certified Minimum 1 Year Free Service Warrenty Remi/Erba/ Ranbaxy , Sencer Senitizer , Senior Executive Chair Foam With Leather Standard Company , Senstivity Disk , Serological Water Bath With Digital Temprature Display Size 605X300x150mm , Serum Amylase(100 Ml),Consumable , Serum Creatinine (100 Ml Bottle (2 X 50 Ml))(Consumable),Consumable , Serum Electrolite Na+ K+ Kit Analizer(50 Test Per Kit),Consumable , Serum T3 Kit, Elisa(96 Test Kit Each),Consumable , Serum T4 Kit, Elisa(96 Test Kit Each),Consumable , Serum Tsh Kit, Elisa(96 / Pkt),Consumable , Sessior 8 Inch Steal , Sevoflurane 20Cc(Each),Consumable , Sgot Kit (Kinetic) 5X20ml 200 Test/Kit , Sgot(25 Ml),Consumable , Sgpt Kit Lyphozyme 5X20 Ml , Sgpt Test Kit Reagent , Sgpt(100 Ml (4 X 25)),Consumable , Shadowlessceiling Light: 28 Dome With Seven Reflector Each Fitted With A Halogen Bulbe And Spherical Filter Glass Ensuring Shadow Free Corrected And Cool Light With A High Intensity Of Illumination (Major Ligh Of 1,20,000 Lux And Satelite Of 75000 Lux , Shadowless Lamp Microsope , Shallis Hemoglobinometer , Sics Blade-Cresent(15 Degree),Consumable , Sics Blade-Sideport(Sideport Entry Knife),Consumable , Silent Disel Generator 15Kvax12kv Dg Set , Silent Disel Generator 20Kvax16kv Dg Set , Siliver Foil , Silk No 1 Cutting Needle 1X12(1X12),Consumable , Simcoe I/A Cannula,Direct,(Num),Consumable , Single Umbilical Catheter With Leur Lock(Fr-3 To Fr 3.5 , L-40 Cm),Consumable , Single Umbilical Catheter With Luer Lock Stopcock Fr-2, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-3, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-4, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-5, L-40 Cm , Slide Box Plastic Cap 100 Slide , Slide Box Plastic Cap 50 Slide , Slide Box Wooden Cap 50 Slide , Slide Holder (Made For Metal) , Slide Rack (Metal) For 25 Slides , Slide Stain Horigontal Cap 50 Slide , Slide Stain Vertical Cap 50 Slide , Slides For Microscopes. (Sep.Glass Slides Plain Size = 76Mmx26mmx1.3Mm, Clean, Scratch Free With Smooth Edges, Uniform Refractive Index, Pack Of 50 , Slit Lamp With Stand , Snellens Vision Box Roted , Sodium Citrate 3.8% - 500 Ml , Sodium Hydroxide (Naoh) (Analar / Gr/Ar) (1X500 Gm = 500Gm),Consumable , Sodium Hypochlorite 5% Solution(5 Ltr),Solution , Sodium Hypochlorite Solution 100 Ml Bottle , Sodium Hypochlorite(0.03 5 Ltr),Solution , Sodium Metabisuiphite (Na2s2o3) (Analar (Gr/Ar) (1X500 Gm = 500Gm),Consumable [710044] , Sodium Nitroprusside (100 Gm),Consumable [710034] , Sodium Pottassium Pack Of 500Ml , Soft Board 3X4 With Cover , Soft Board 4X5 With Cover , Soft Roll 4” , Soft Roll 6” , Solar Home Light System With Structure (Mne) Specification 2 Noof Cfl Rating 12V 40 Ah 7W Battery Capacity , Solar Inverter 850 Kva. Double Bettery Syestem. , Solar Led Street Lightning System Along With Mounting Pole , Spaculam , Speaker Output4 Voicecoll) , Spectra Optia Platelet Kit, Model : 10400(Packing Size : 6 Kits),Consumable , Sphygmomaw Meter , Spinal (L.P.) Needle Disposable 24Gconsumable , Spinal (L.P.) Needle Disposable 26Gconsumable , Spinal Needle G-22 L-120 Mm*0.71/Piece , Spinal Needle G-23 With Metal Stylet. , Spinal Needle G-27 L-120 Mm*0.40/Piece , Spine Board (Should Be In Plastic Material At High Strength And Waterproof. It Should Be 4 Rules For The Quick And Total Fixing Of The Head Immobilizer And Two Cavities Waherthe Board Lays On The Floor.When The Base Is Blocked In The Traditional Way, That Allow A Avoid Damaes Of Rip-Off Straps During The Usage Of Accommodation In The Ambulance It Should Be Handles For The Transport, Supplied With 3 Belts With Rapit Unhooking Buckle Should Have Maximum Radio Transparemcy To Make Exams Without Compromise Patient Condition.) , Spoon , Spring Balance Capacity 15 Kgs (For Baby Weighing) , Sprit Lamp (Steel) , Sputum Cup With Caps Pack Of 100Ml , Spuum Containersep.(Cups Made Of Special Medical Grade Polypropylene, Thin Plastc, Transulucent, Diameter- 4Cm,Capacity-30Ml, Srewable Cap Should Also Be Made Of Special Medical Grade Polypropylene And Should Be Air Tight. Leak Proof. , Stain (1X25 Gm = 25 Gm),Consumable , Stainic Rack(Each),Consumable , Staining Kit Reticulin(100 Test),Consumable , Staining Rod Steel (60Cm) , Stainless Steel Wire 30G , Steam Stock System & Mositure Trap , Steel Troch With 3 Cell , Sterilant Cold Disinfectant For Dialysis Containing Peracetic Acid Hydrogen Peroxide Acetic Acid(5 Ltr Can),Consumable , Sterilant Hot Disinfectant For Dialysis Containing 21% (Approx) Citric Acid, Malic Acid, Lactic Acid(5 Ltr Can),Consumable , Sterile Hypodermic Syring With Needle 20 Ml , Sterile Hypodermic Syring With Needle(5 Ml),Syrings , Sterile Hypodermic Syring With Needle, Mfg By Ph Health Care Pvt Ltd(10Ml),Consumable , Sterlium 500 Ml , Sterlizer Electrically Operated (Size 10X5X3) Isi Marked , Sterlizer Electrically Operated (Size 12X6X4) Isi Marked , Sterlizer Electrically Operated (Size 8X5X3) Isi Marked , Sterlizer Electrically Operated With Automatic Cut Off Ss 12X6X4 , Sterlizer Electrically Operated With Automatic Cut Off Ss 20X6X4 , Stethescope Super Quality , Stethoscope Litman Type , Stop Wathc Digital , Strecher Folding , Stretcher Trolley 4 Wheel 79X24X30 Without Handle , Stretcher Trolley 6 Wheel 79X24X30 Without Handle , Strip For Albumin Urine And Suger , Strip For Malaria Antigen, P Vivex, P Falciparum (50 Tests) , Suction Machine Portable , Suction Catheter Assorted 10 No/Each , Suction Catheter Assorted 9 No/Each , Suction Catheter, Sterile(Size Fg 20 (Disposable, Sterile Each)),Consumable , Suction Catheter, Sterile(Size Fg 22 (Disposable, Sterile Each)),Consumable , Suction Catheter, Sterile(Size Fg 6 (Disposable, Sterile Each)),Consumable , Suction Derice Apparatus , Sugar Albumin Strip , Sulfolyser For 5-Part Hematology Analyser All Model (Pack Size 5000 Ml),Consumable , Sulfur Powder , Sulphosalicylic Acid 3% W/V Pack Of 500Ml , Sulphuric Acid ( H2so4, Molecular Wt.98.08, Minimum Assay: 98% Colour: Clear , Sumag( ),Cream , Surface And Fogging Disinfectant Stabilised H202,10-11%W/V With Diluted Silver Nitrate Sol. 0.01%W/V(5 Litre Can),Each , Surface And Fogging Disinfectant Stabilised H202,10-11%W/V With Diluted Silver Nitrate Sol. 0.01%W/V(5 Litre Can),Each , Surface Disinfectant 10 Minute Aldehyde Free Disinfectant Containing Potassium Mono Per Sulphate Powder((5Kg Packet)),Powder , Surface Disinfectant 10 Minute Aldehyde Free Disinfectant Containing Potassium Mono Per Sulphate Powder((5Kg Packet)),Powder , Surgical Blade Isi Marked, Size 11(100 Per Packet),Surgical Material , Surgical Blade Isi Marked, Size 15(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 22(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 23(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 24(100/Pkt),Surgical Material , Surgical Spirit(100Ml),99.9 %Bottle , Surgical Spirit(100Ml),Bottle , Surgical Spirit(450 Ml 99.5 %,Consumable , Surical Alumenium Waking Stick , Suter(8/0 (01 Box)),Consumable Pack Of 12 Foils , Suture Needle , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 11-15 , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 1-5 , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 16-20 , Synthetic Absorbable Suture 1 With 1/2 Circle Taper Cut Needle (H) Size :1 40Mm Length 90Cm Polyglycolic Acid (Pga) (12 Foils Per Pkt) , Synthetic Absorbable Suture 2/0 With 1/2 Cir Rb Needle Size:2/0 30Mm Length 90Cm-Polyglycolic Acid (Pga) 12 Foils / Pkt , Synthetic Absorbable Suture 2/0 With 1/2 Cir Rb Needle Size:2/0 40Mm Length 90Cm-Polyglycolic Acid (Pga) Pack Of 12 Foils , Synthetic Absorbable Suture 3/0 With 1/2 Cir Cutting Needle Size:3/0 36Mm Length 70Cm -Polyglycolic Acid(Pga) 12 Foils / Pkt , Synthetic Absorbable Suture 3/0 With 1/2 Cir Rb Needle Size:3/0 20Mm Length 70Cm-Polyglycolic Acid (Pga) Pack Of 12 Pc , Synthetic Absorbable Suture 3/0 With 1/2 Cir Rb Needle Size:3/0,40Mm Length 90Cm-Polyglycolic Acid (Pga) Pack Of 12 Pc , Syring Needle Distroyer Electric Standard Company , Syring Needle Distroyer Menualstandard Company , System For Delivering Saturated Atomized Steam For Decontamination Of Surfaces , Tasla Iron Standard Size , Test Tube 12 X 100 (Medicm Size) 100/Pkt , Test Tube 12 X 75 (Small Size) 100/Pkt(12 X 75 (Small Size) 100/Pkt),Tube , Test Tube 15X125 [987819] , Test Tube Medium (12X100) 100Eack/Pkt(Each),Consumable , Thema Col Box (25Cmx21cm) , Thematic Apperception Test With Cards And Manual , Therma Coal Box(Size 9X6x6) , Thermometer Guaze With Automatic Display , Thermometer Manually For Fever Tamprature , Three Layer Surgical Mask Pack Of 100Pc , Thrombin Time Kit(10X3 Ml),Consumable , Thyroxine(T3),Pack Of 96Test , Thyroxine(T4),Pack Of 96Test , Thread Real For Suture Cotton , Tips For Auto Pippetes 10 To 100 Micro Litres , Tissue Paper Roll(Each),Consumable , Tissue Roll Paper (13Cm) , Tmt Graph Paper A4 Size, 100 Piece/Pkt , Toilet Brush Super Quality , Tooke Corneal Knife(Num),Consumable , Torch 3Cell Steel Body , Torch With Cells , Torch With Three Cell Isi Market Medium , Torch With Two Cell Isi Market Medium , Total Protein (100 Ml),Consumable , Total Protein Lysozyme 1X50 Ml , Total Protein Test Kit(100 Ml Bottle),Consumable , Tourniquet With Belt(Mfg By Precious Life Care Pvt Ltd)(Good Quality Pairs),Consumable , Towel Mayo Forcep Size 8 To 15 , Triglycerides (Enz.End Point) Liquisat) Pack Of 10X10ml , Trolley For Patient Ss , Tsh (Elisa) Pack Of 96Test , Tube Sealer Electric , Tuberculin Syringe , Two Step Slit Lamp , Typhoid Test Card Single Test For Widdal , Tyvek Suit Kit - 1 Pcs Full Body Cover, 1 Pcs 3Layer Mask, 1Pcs Gloves, 1 Pair Shoe Cover, 1 Pair Of Goggles(60 Gsm Non Wooven Fabric),Consumable , Uero Bag 2Letrs Capacity , Umbical Cord Clamps- Plastic Material (Box Of 100 Clamps) Consumable , Urea (Liqustat) Pack Of 10X10ml , Uric Acid (End Point) Pack Of 10X10ml , Urinary Drainage Bag (Paediatric)(100 Ml / Pc, Each),Consumable , Urinary Drainage Bag 2 Litre Cap With Non Return Valve (Eo Sterile) , Urinary Drainage Bag Cap With Non Return Valve (Eo Sterile)(2 Litre, Each),Consumabl , Urine Caontainer Sterile 30Ml Pack Of 100 , Urine Container 5Ml Disposable (50 Per Pkt) , Urine Container Size Of The Container Shall Be 30Ml Disposable (50 Per Pkt),Consumable , Uristic For Albumin/Suger Urine Pack Of 100 Strips , Urosticks(50/Pkt),Consumable , Utility Gloves , V.P Shunt Medium Pressure (Venticular Peritonial Shunt, (Venticular Catheter 15Cm Length, 1 Distilled Catheter 75 L, Struit Stylet)(Each),Consumable , V.P.Shunt(Low Pressur),Consumable , V.P.Shunt(Medium Pressur),Consumable , Vaginal Speculam Sims , Vaginal Speculam Ss Cusco Large , Vaginal Speculam Ss Cusco Medium , Vaginal Speculam Ss Cusco Small , Vaseline White/Yellow(1/2 Kg),Consumable , Vdrl (Rpr) 1X100 Sd Strip For Syphlis , Vdrl Kit (Strip) 50 Test/Kit),Consumabl , Ventilator Neoatal & Pediatric - Volume Cycle Ventilator, Microprocessor Based Assisted Controled Short Term For Prolonged Ventilation Can Be Provide, Volume Delivery 20 Ml To 2000 Ml Cmv, Simv, Asb, Peep, Cpap Modes Easy To Handle And Operational, Electrically Operated, Air Compresson Should Be Provided Along With The Ventilator Miounted On Same Trolley, Nebulizer & Humidifier Both Adult And Pediatric, Ups System And/ Or Battary Backup For Compressor And Ventilator, Adult, Pediatric And Neonatal Breating Cicuits (Each) Alarms Display Facillity, Fio2 Dispaly Digital Display- All Set Parameter Should Be Display Automatically , Vineland Adaptive Behavior Scale (Indian Adaption) With Manual , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 2Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 3Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 5Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Heavy Dencity 10000 Glass Syring 2Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Heavy Dencity 10000 Glass Syring 3Ml , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Heavy Dencity 10000 Glass Syring 5Ml , Visiter Chair Three Seater Mettalic With Handle (Ss) , Vtm - Hi - Media With 2 Swab : (For Swine Flu) Vtm Standard Kit(3Ml Vial With 2 Regular Swabs) , W/V Available Iodine In A Non-Oxynol With Solubleiodine Suractant Base With Sodium Iodide(Less Than 1% W/V And Surfactant Less Than 5% W/V500 Ml), Consumable , Wall Fan -18 Complete & Instaltion Charge (Standardisi/Iso Reputed Company) , Wall Thermometer , Warm Bag , Warm Sleeping Bag For Neonates , Wash Bottel Plastic 500Ml , Washing Machine Have Appliance 7Kg , Waste Matarial Drum Swing Model 30 Ltr. , Waste Matarial Drum Swing Model 60 Ltr. , Water Bath Rectangular Thermostatic (Double Walled)- Spec.In Is A Double Bath With Inner Chamber Made Of Stainless Steel And Outer Wall Made Of M.S Duly Powder Coated Paint.The Gap Beteween Outer And Inner Wall Is Filled With Special Glass Wool Insulation.The Conecntric Ring Can Be Removed To Accommodate Containers Of Various Sizes. Temperature From Ambient To 100 Digree+1Digree C Is Controlled By Improted Thermostant. 355X405x100mm (12 Holes Of 75Mm Dia) 14 Ltrs., Urnie Analyzer ;-Long Life Light Illminator Measuring System With 4 Wavelenght Improves The Sensitivity Accuracy And Precision Of The Result . Use Can Edit Sample Id/Patient Name . Automatically Detects The Test Strip. Can Be Connected With Exeternal Barcode Reader&Urine Sediment Analyzer. Sutable Strip Uts-8,10,11,&11 Ma , Water Cooler 150X150ltr Isi Market , Water Cooler 20X40 Ltr Isi Market , Water Cooler 40X80 Ltr Isi Marked , Water Cooler 60X120ltr Isi Marked , Water Cooler With Dispenser (20 Litre) Isi Mark , Wbc Dialuation Fluid(Mfg- Precious Life Care Pvt Ltd)(500 Ml Bottle),Consumable , Wbc Diluting Fluid 500Ml , Wbc Pipet , Weghing Machine , Weighing Machine (1Gm To100gm) , Weighing Machine Pediatrics , Weight3.00Kg , Wheel Chair With Hand, Foot And Neck Rest Ss, , Whitacre - Pencil Point Spinal Needle 25 G With Introducer , White Petrollium Jelly 1Kg , White Petrollium Jelly 20 Kg , Widal 4X5 Ml [987811] , Widal Slide Test(4X5m1 With Control),Consumab , Widdal 2X2 Tube Test Kit For Typhoid , Widdle Reapid Test Cardsingle Test , Widdle Reapid Test Card Antigen Pack Of 50Ml , Wiper Medium Size , Wiper Standard Size , Wooden Stick/Broom Stick (8Inches) , X-Rayfilm (Dihl),Consumable 8 Inchx 10 Inch , X-Ray Cassets With Screen Size 10X12 , X-Ray Cassets With Screen Size 12X15 , X-Ray Cassets With Screen Size 8X10 , X-Ray Cassets(6.5X8.5),Consumable , X-Ray Cassets(8X10),Consumable , X-Ray Chest Stand , X-Ray Developer Powder (13.5 Liter),Consumable , X-Ray Film 10 X 12 50 Sheets/Pack , X-Ray Film 10X12(50 Sheet/Pack),Consumable , X-Ray Film 12 X 12 50 Sheets/Pack , X-Ray Film 12 X 15 50 Sheets/Pack , X-Ray Film 12X15(50 Sheet/Pack),Consumable , X-Ray Film 14 X 14 50 Sheets/Pack , X-Ray Film 14 X 17 50 Sheets/Pack , X-Ray Film 6.5 X 8.5 50 Sheets/Pack , X-Ray Film 8 X 10 50 Sheets/Pack , X-Ray Film 8X10(50 Sheet/Pack),Consumable , X-Ray Film Digital 11X14 , X-Ray Film Digital 14X17 , X-Ray Film Digital 8X10 , X-Ray Film Fixer(Powder To Make 13.5 Liters-Pkt),Consumable , X-Ray Film Fixer(Powder To Make 9 Liters-Pkt),Consumable , X-Ray Film-Polyster Based Imaging Film 35.6Cmx43.2Cm (14X17)(Size-50 Sheet In One Packet),Consumable , X-Ray Fixer 13.5 Lit , X-Ray Fixer 22.5 Lit , X-Ray Flimpack Of 1X50 Size 10 Inchx 12 Inch(Dihl),Consumable , X-Ray Flimpack Of 1X50 Size 14 Inchx 17 Inch(Dihl),Consumable , X-Ray Grid 12X15 , X-Ray Grid 8X10 , X-Ray Half File Glomer 6X15 , X-Ray Half File Glomer 6X17 , X-Ray Hanger Size 10X12 , X-Ray Hanger Size 12X15 , X-Ray Hanger Size 6.5X8.5 , X-Ray Hanger Size 8X10 , X-Ray Hangers(10X12),Consumable , X-Ray Hangers(12X15),Consumable , X-Ray Hangers(6.5X8.5),Consumable , X-Ray Hangers(8X10),Consumable , X-Ray Lead Number (A To Z & 0 To 9) , X-Ray Led Aprin Standard Size , X-Ray Led Gloves , X-Ray Steel Ka Tank 13.5 Lit. , X-Ray Steel Ka Tank 19 Lit. , X-Ray Table For Patient Examine , X-Ray View Box Double , X-Ray View Box Single , X-Ray View Box With Auto Sensor (Four Film) , X-Ray View Box With Auto Sensor (One Film) , X-Ray Film-Polyster Based Imaging Film 30.5Cmx30.5Cm (12X12)(Size-50 Sheet In One Packet),Consumable , X-Ray Film-Polyster Based Imaging Film 35.6Cmx35.6Cm (14X14)(Size-50 Sheet In One Packet),Consumable , 2Tu Ppd Vial 5Ml , Xylene (Sulphur Free)(1 X 2.5 Lit),Consumable , Zipper Ploy Bag 4X4 , Zipper Ploy Bag 4X6 , Zipper Ploy Bag 9X6 , Zipper Poly Bag (Size 5”X3”) , Zipper Poly Bag (Size 6”X5”) , Zipper Polybag 10X8’’ , Zipper Polybag 8’X6’ , Poly Bag Black 16X18’’ , Air Conditioner Window 1.5 Ton 3 Star , Air Conditioner Window 2 Ton 3 Star , Air Conditioner 1 Ton Split 3 Star , Air Conditioner 1.5 Ton Split 3 Star , Air Conditioner 2 Ton Split 3 Star , Stabilizer For Ac , Office Almirah , Laser Printer , Laser Printer All In One , Inkjet Printer , Desktop I3 Windows 11 , Desktop I5 Windows 11 , Public Place Seater Bench Ss Without Backrest , Ultrasound Unit (1 Mhz) For Physiotherapy , Foot Drop Splint , Cock Up Splint , Finger Splint , Tens Machine , Display Board With Glass , Laptop I5 Window 11 , Shoulder Wheel , Finger Exerciser Web , Shoulder Pully T-Type , Spiro Meter With Disposal Mouth Piece , Lower And Upper Extremity Static Cycle , Iron Rack , Industrial Rack , Exicutive Revolving Chair , Zip Lock Polythene Pp Pouche 12 To 19 Inch , Zip Lock Polythene Pp Pouche 6 To 9 Inch , Straight Plastic Brush , Centrifuge Tube 50Ml , Card Bord Box Small , Laminar Air Flow , Filter Paper , Biohazard Polythene Bag , Three Seater Chair , Cupboard (Closed Rack) , Water Cooler 60Ltr , 8.0 Silk Suture , Dispovan Syringes 10Ml , Dispovan Syringes 05 Ml , Blood Transfusion Set , Iol Non Foldable Lenses , Black Gogles , Micropore Paper Tape 4 Inch , Micropore Paper Tape 1 Inch , Cotton Bundles , Sterile Pad , K Wires 1 1.5, 2, 2.5 Mm , Hand Drill , Hydrolic Ot Table , English Plier , Bone Holding Forcep For Radius Ulna Bone , Bone Holding Forcep For Humerus Bone , Bone Holding Forcep For Femur Bone , Tbw Ss Wires No. 18, 20,22 No. , Patella Holding Forcep Large , Patella Holding Forcep Small , Plate Holding Forcep Small , Plate Holding Forcep Medium , Plate Holding Forcep Large , K-Wire Cutter Medium , K-Wire Bender Steel , T Handle & Ss Chuck Small , T Handle & Ss Chuck Large , Wire Passser Small , Retractor Right Angle Medium , Retractor Right Angle Small , Retractor Right Angle Large , Bone Spikes Small , Bone Spikes Medium , Hohmann Retractor , Bone Cutter Small , Lenz Bone Holding Forcep , Towel Clips Small , Towel Clips Medium , Steel Drill Bits 2.7Mm 3.2Mm 3.5 Mm Steel , Screw Driver For 3.5 Mm Screws , Canullated Drill Bit For4mm Screws , Canullated Tap For4mm Screws , Steel Hammer Heavy , Bone Punch , Currete Straight , Currete Curved , Osteotome Small , Osteome Medium , Osteotome Large , Bone Gauze Small , Bone Gauze Medium , Bone Gauze Large , Electric Drill Set Man Man , Canulated Reamers For Femur , Hooks For K Nail Retractor , Reamers For Radius Ulna Nailing , Extractor For Radius Ulna Nailing , Drill Sleev For 2.7 & 3.2 Mm Drill Bits , Hoilow Mill , Zigli Saw , Eletric Torniquet , Pneumatic Tourniquet , Radient Warmer , Ambu Bag Pediatric , Suction Machine Foot Oprated , Suction Machine Electric , Thermameter , Hub Cutter , Oxygen Tube , Oxygen Hood , Oxygen Mask , Stethpscope , Laringoscope , Laringoscope Blade 0 No , Laringoscope Blade 1 No , Tourch , Infentometer , Measuring Tape , Diamond Marker , Tissue Roll , Marker Pen Red Black , Auramine -O , Hydrochloride Acid , Broom Stick , Zipper Polythene , Measuring Cylinder 1000Ml , Measuring Cylinder 500Ml , Methnol , Apron Coton , Bio Hazard Lables , Amber Coloured Bottle 250Ml , Brown Tape , Slide Box For 100 Slide , Beaker 500Ml , Glass Ware For Stain Preparation Meassuring Cylinder-Graduated 100Ml , Glass Ware Round Flate Bottom Flask-1 Lit , Stainless Steel Scissors , Water Bath Digital , Hand Wash 1000Ml , Laminar Air Flow , Towel , Rack Steel , Lens Paper , Ppd Vial 2 Tu , Ppd Vial 5 Tu , Distilled Water , Spirit Lamp Steel , Phenyl 40% , Tri Sodium Citrate , Di Sodium Hydrogen Phosphate , Potassium Di Hydrogen Phosphate , N-Acetyl L-Cystein , Glass Slide , Cryo- Vial Sterilr With Cap 1.5Ml , Tips 200 ?L Sterile With Box , Tips 1000?L Sterile With Box , Tips 1250?L Sterile With Box Long 1Ml , Bags For Waste Bin Black 30L , Bags For Waste Bin Red 30L , Bags For Waste Bin Blue 30L , Disposable Laboratory Coat Large White Colour , Disposable Laboratory Coat Medium White Colour , Disposable Laboratory Coat Large Blue Colour , Disposable Laboratory Coat Medium Blue Colour , Storage Box With Lid For 0.2 Ml Pcr Tube , Steel Rack For 50 Ml Conical Tube , Plastic Rack For 50 Ml Conical Tube 24 Position , Sodium Hypochloride , Pasteur Pipette Individually Packed Sterile 3Ml , 50 Ml Pptubes For Centrifuge , Pcr Tube 0.2 Ml , Falcon Tube Stand , Refrigrator 322 Liter , Ups Double Battery , Ceiling Fen , Delivery Table , Labour Table Mettres , Almirah , R O Machine , Auto Clave Drum Large , Auto Clave Drum Medium , Auto Clave Drum Small , Kidney Tray , Dental Chair , Uv Chamber , Ultrasonic Scale , Compressor For Dental Chair , Glass Bed Sterilize , Aerotor , Xtracton Forcip Set , Elevator Set , Diagnostic Instrument Set For Dental , Glass Slab , Restrotiv Instrument Set , Enoo Motor , Rbg Size 2 Digital Infra Oral Xray Sensor With Desktop , Aerotor Burs , Artery Forcip , Episiopomy Ceizer , Bowl , Thumb Forcip , Delivery Tray , Office Table , Plane Seizer , Stich Cutter , Needle Holder , Spung Holder , Chittle Forcip , Cord Cutting Seizer , Tooth Forcip , Non Tooth Forcip , Knife Holder , Bp Insturment Digital , Cidex Tray , Mezenba Seizer , Ot Fogging Machine , Weight Machine Adult , Office Chair , Nebulizer , Foot Step , Plastic Chair , Invertor With Battery , Rivolving Chair , Patient Stool , Drug Cart , Stadiometer , Examination Table , Fetal Dopler , Thermometer , Flying Catcher , Autoscope , Bio Waste Bucket , Digital Wall Clock , Equipment Tray , Fire Extinguisher , Three Buckt Trolly , Crash Card Trolly , Delivery Set , Epigiotomy Set , Mtp Medicine Set , Multipera Monitor 5 Pera , Ot Table , Ot Table Hydrolic , Ot Light Celing , Spot Light , Hb Meter , Exhaust Fen , Suction Machine Electric , Finger Print Scaner Machine , Plastic Tub , R O Machine 60 Liter , R O Machine 80Liter , Kmc Chair , Electric Water Geyser 10 Ltr.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
Madhya Pradesh View Result →
11.
Educational and Research Institute #10317998 AOC
E-TENDER FOR PROCUREMENT OF EQUIPMENTs, INSTRUMENTs, MACHINERIES, TOOLS ETC. RELATED TO LABORATORIES AND WORKSHOPS OF PHYSICS, CHEMISTRY, CIVIL ENGINEERING, OF DARJEELING POLYTECHNIC, KURSEONG, DIST. DARJEELING, 734203- 1 LIST OF REQUIRED MATERIALS FOR CHEMISTRY LABORATORY 2 Buerette(Borosilicate Rotaflow 50ml) 3 Buerette stand andclamp 4 Bunsen Burner with Gas pipe 5 Wire Gauge and Stand 6 Tissue paper roll 7 Digital Conductivity meter(Desktop) 8 Redwood viscometer 9 Abels flash point apparatus 10 Pipette(Borosilicate 25ml) 11 Hand Glove 12 Spot test plate(6 cavity) 13 Filter paper - 110mm (1 roll sheet) 14 Wash bottle(Polyethylene 500 ml) 15 Muffle furnace 16 100 ml volumeteric Flask(Borosilicate) 17 Photo Colorimeter(Desktop) 18 Analytical Balance 19 Electric oven 20 Stop watch 21 Thermometer(0 -100 ˚C) 22 LIST OF REQUIRED MATERIALS FOR CIVIL ENGINEERING LABORATORY 23 AGGREGATE IMPACT VALUE(AS PER IS 2386) 24 AGGREGATE CRUSHING VALUE TEST(AS PER IS 2386, PART 4 40 T CAPACITY) 25 FLAKINESS INDEX &ELONGATION(AS PER IS2386 SPECIFICATION) 26 COMPLETE ABSOLUTE VISCOSITY TEST APP CONFIRMING TO IS 1206, PART II-1978(AS PER IS:1206, PART II) 27 PENETRATION TEST APP FOR BITUMEN(AS PER IS:1203 -1978, 220V, CAPACITY 50 & 100 Gm) 28 RING AND BALL APPARATUS(AS PER IS 1209 - 1978) 29 REBAR LOCATOR(DIM 120 X 60 X 25 mm) 30 CONCRETE CORE CUTTER(45L CAPACITY, DRILL DIA 132MM, VOL 93 X 35X 24 mm) 31 REBOUND HAMMER(IMPACT ENERGY 2.207 Nm, WEIGHT 5770 gm, RANGE 75mm) 32 BERNOULLIES THEOREM APPARATUS(MS SUMP TANK 80L, MEASURING TANK 10L, ISI MARK GI PIPES & CONTROL VALVE) 33 VENTURIMETER APPARATUS(SLUMP TANK 200 X 500 X 300 mm, 0.5 HP PUMP, COLLECTION TANK 500 X 500 X 600 M) 34 Piezometer with necessary apperantunces(Piezometer with Head Tank 300x300x450mm, measuring tank 300x300x300mm, Sump tank 600x600x300mm,0.5 HP Pump, Connecting pipes with necessary fittings and valves.) 35 U Tube differential Manometer with necessary apperantunces(U Tube differential Manometer Head Tank 300x300x450mm, measuring tank 300x300x300mm, Sump tank 600x600x300mm,0.5 HP Pump, Connecting pipes with necessary fittings and valves.) 36 Bourdon’s Gauge for measuring water pressure(Head Tank 300x300x450mm, measurement tank 300x300x 300mm, Sump tank 600x600x300mm,0.5 HP Pump, Connecting pipes with necessary fittings and valves.) 37 Pipe Friction Apparatus(Capacity 0.5HP, Sump Tank Capacity 1200 x 300 x 400 mm) 38 Pitot tube(Pitot Tube- Material Copper/SS of compatible size,Sump Tank 1200 x 300 x 400 mm) 39 TURBITY TEST APPARATUS(200 NTU, DIGITAL, LED DISPLAY, 230 V, 50 HZ) 40 APPARATUS FOR SUSPENDED SOLIDS DISSOLVED SOLIDS AND TOTAL SOLIDS IN WATER(HM DIGITAL, LCD DISPLAY, 357 A POWER) 41 HARDNESS TEST OF WATER APPARATUS(AE-201-40, 5-0.1-2 MG/L) 42 CHLORINE CONTENT DETERMINATION TEST APP(DPD METHOD, AE-201-0.1-2MG/L) 43 ARSENIC CONTENT DETEERMINATION TEST APP(5202 AS PER BP) 44 FLUORINE CONTENT DETERMINATION (AS PER BP) 45 PH METER(AS PER BP ) 46 JAR TEST APPARATUS(As per IS-3025(Part 50):2001 - Digital Jar test withJar capacity 1000ml, 30 to 150 RPM ) 47 PYCNOMETER BOTTLE(1L CAPACITY) 48 VANE SHEAR TEST APPARATUS(SPRING SET OF 2 KG-CM, 4.6 & 5 KG -CM) 49 VENIER TRANSIT THEODOLITE WITH TRIPOD STAND(MAGNIFICATION = 30 X FOCAL LENGTH =178MM) 50 QUICK SETTING DUMPY LEVEL WITH TRIPOD STAND(MAGNIFICATION = 24 X ANGLE OF VIEW = 2,BRAND =SOKIA) 51 PRISMATIC COMPASS WITH TRIPOD STAND(DIAMETER = 120 mm, DISPLAY = ANALOG) 52 PLANE TABLE WITH ACCESSORIES WITH STAND(TABLE SIZE= 23 X 32, MATERIAL = WOOD/ ALUMINUM/ BRASS, BRAND = SAPPHIRE) 53 GPS INSTRUMENT(GARMIN GPS 64sc SITE SURVEY, Handheld, SCREEN SIZE 2.5 inch ) 54 30m measuring METRIC TAPE ( Fibreglass)(Materials = rubber printing +ABS Plastic +PVC (Fibre glass) , Length = 30 m) 55 DIGITAL WEIGHING SCALE(Capacity of 20kg, with accuracy of 0.1gm) 56 DIGITAL WEIGHING SCALE(Capacity of 5 kg, with accuracy of 0.001gm) 57 LIST OF REQUIRED MATERIALS FOR PHYSICS LABORATORY 58 Boyle’s law apparatus complete set (With Mercury) 59 Stoke’s law apparatus for determining viscosity of liquid (Complete Set)(Complete Set with Glycerine) 60 Friction Apparatus(Complete Set with pulley and weights) 61 Flat plates of Brass / Glass(100x60x18mm) 62 Blocks of Wood with Hooks(12 cm X 8 cm X 8 cm) 63 Spring Balance(Range 5 to 1000 gm) 64 Set of 50 gms slotted weights(Slotted Weight - Iron Chrome Plated - 50gm × 10 = 500gm) 65 Flywheel Apparatus(Low Speed) 66 Meter Rod(Flat Meter Rod Scale) 67 Helical Spring(with Pointer and Hook) 68 Rigid Support (with Hanger) 69 Spherometer(5 mm to 200 mm) 70 Screw Gauge(0 - 25 mm, 0.01 mm)(Stainless Steel) 71 Vernier Callipers(0 - 12.5 cm metallic) (Brass) 72 Specific gravity bottle (with cap)(25ml) 73 Physical Balance + Weight Box(with weight box) 74 Convex Mirror(FL - 15cm, 20cm, 25cm) 75 Concave Mirror(FL - 15cm, 20cm, 25cm) 76 Wooden Bridge(for physicsl balance) 77 Wooden METRE Scale(1 m wodden scale) 78 Cantilever (Metal Bar)(1 m Metal rod with marking) 79 Metal Clamp(To fix cantilever to table) 80 Glass Slab(100x60x20 mm for refraction experiment) 81 Wodden Board(30x20 cm for refraction experiment) 82 Optical Bench(1.5 Meter with Both Rod Stainless Steel with Four heavy metal slider and with accessories.) 83 Convex Lens 50 mm diameter(25cm FL) 84 P O Box(Plug Type (Constantan & Manganin Coil)) 85 Resistance Box (1-500Ω) (1-500Ω range) 86 Resistance Box (1-1000Ω)(1-1000Ω range) 87 Resistance Box (1-10000Ω)(1-10000Ω range) 88 Rehostat(6 inches 100 ohms 1 ampere for resistance variance) 89 Resistance (2.5Ω, 5Ω, 10Ω, 15Ω)(5 of each value) 90 Battery Eliminator(2A, 12 V range) 91 P.N Junction Diode Characteristics Apparatus(Two Variable DC Regulated Power Supply (0 - 3V & 0 - 30V) with Two Analog Moving Coil Meters :( Dual range (3V/30V, 100µA/10mA). & 4mm Banana type sockets for connections. P-N Diode type: OA -79 2 Pcs) 92 Laying and Jointing PVC Pipe. Heading 93 8051 Trainer kit(8 BIT EMBEDDED MICROCONTROLLER TRAINER FEATURES • Single board design with various resources • Excellent training platform for embedded applications • Software development tools include assembler and ‘C’ compiler • Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS • Experimental board for 40 pin MCS51 and AVR family of microcontrollers • In-system programming (ISP) facility for many microcontrollers • Double RESET signal with manual key • Crystal frequency: 11.0592MHz • On-board RS232 compatible serial interface terminated in a 9 Pin D female connector • 4×4 matrix keyboard • 16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment • Four 7-segment LED displays • I2C EEPROM (24Cxx) • Real time clock (DS1307) with lithium battery and SRAM • 8-high current output port (500mA) for driving external loads • Two 12V sugar cube relays • Continuous tone piezo buzzer • Temperature sensor socket with thermostat functions • Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591 • All port-pins available on 10-pin box header • 8 LEDs for easy logic state monitoring • 8 input trigger switches using 8 push buttons • ISP programming with Flash ISP for AT89S51/52/8252/AVR • Infrared remote control receiver module IC supported • P89V51RD2BN • AT89S52 Installable software on CD • Programmers notepad : Free, open source, text editor • Flash ISP programmer software for 89SXX • Bascom basic compiler (demo version) • MIDE-51: An IDE for MCS-51 microcontroller • WinAVR : open source C compiler for AVR • Sample programs for peripherals DC 12V/500mA output power supply EXPERIMENTS • Study of LED blink • Study of dancing light • Study of LCD display • Study of LCD-keyboard display • Study of 7 –segment display • Study of RC5 remote control test program) 94 Suitable 8051 Trainer kit(With suitable Hardware and related software including AC variable voltage (0-10V) /current (0-5A) source, digital panel type ammeter & volmeter. Dedicated Intel 8051 based kit with ADC, 8255, 2K (extendable upto 8K) RAM & ROM, 8279,8253, necessary DC power supply and connecting cords.) 95 Suitable 8051 Trainer kit(Motor control interface card should have---- Motor Driver Unit, Interfacing Cards,Terminal connectors 20 - pin FRC Box Connectors, cables.8051 Micro Controller Kit DC Motor spec: Voltage 6.0V (Range: 1.5-12.), Speed: 2,700 rpm, Current: 0.02A, Torque: 5.88 mN. M;) 96 Suitable 8051 Trainer kit(Stepper Motor interface kit should have -- • 5V Stepper Motor • Angle control / Clockwise/ Counterclockwise • 1.8 degree Step Angle , • 34 mm Motor Length, • 1300 g.cm Holding Torque, • 6 no. Lead Wire • 0.3 A Rated Current, • 40 Ω Phase Resistance, • 20 mH Phase Inductance, • 0.18 Kg Motor Weight ; • Motor Driver Unit, Interfacing Cards, Terminal connectors 20 - pin FRC Box Connectors, cable, data sheet suitable for 8051 Micro Controller Kit) 97 Suitable 8051 Trainer kit(Microcontroler : Intel 80C51 Operating at 12 MHz Memory : -32 KB Onboard User Program Memory -12 KB Battrey Backed Up User program Memory -16 KB Battrey Backed Up User Data Memory Display : 40 Characters X 2 Lines LCD Display Keyboard : ASCII Keyboard Timer Counter Chip : 8253; 2 Counters available for User PPI : Two 8255 chips giving 48 TTL I/O Lines All Signals Terminated on 2 26 Pin FRC Connectors Serial Port : RS-232 Compatible serial port using 8250; signals treminated on a 9-pin D-type connector Expansion Bus : All address data & control bus brought out on 50 pinFRC connector for expansion Study Card Support : Dyna Series study cards support on this connector. All programs for study cards included in monitor program Modes Of Operation : -Introgation Mode : For interactive dialog with system -Assembler Mode : Line Assembler inbuilt in monitor helps you assemble programs directly -Single Step Mode : This mode is useful for Single Stepping inserting / removing breakpoints and debugging Software : – Powerfull Monitor Software with standard commands like move, fill, display/modify registers, execute Program, upload /download etc. – Single line assembler / dis-assembler.) 98 Suitable 8051 Trainer kit(With suitable Hardware and related software including AC variable voltage (0-10V) /current (0-5A) source, digital panel type ammeter & volmeter, frequency display,DW transformer of suitable rating for phase shifting (0-45 degree lead/lag). Dedicated Intel 8051 based kit with ADC, 2K (extendable upto 8K) RAM & ROM, 8279,8253, necessary DC power supply and connecting cords.) 99 8086 Trainer kit/ PC (Simulator) (8086 (INTEL),Operating Frequency : 6.144MHz crystal,32KB-SRAM for user Data,16KB-EEPROM (software monitor program),2x16 Char LCD display,Serial interfacing using 8251, 48 Programmable I/O Pins for ( 2 x 8255),Three 16-bit programmable timer (8253/8254),40-Pin FRC connector for Bus Extension,20-Pin FRC connector Add-on Interface from 8255,9-pin DB connector for UART (RS232) interface,Built-in assembler and dis-assembler,101-PC Type keyboard to enter user address/data commands.) 100 Zener Diode Characteristics/ Breakdown Voltage Kit(trainer kit) 101 JFET/MOSFET characteristics Kit(trainer kit) 102 UJT Relaxation Oscillator kit(trainer kit) 103 p.f. Meter, (Resolution - 0.001 p.f, 110/230 V AC) 104 inductance box, (10 micro Henry, 100 micro Henry, 1 mili Henry, 10 mili Henry, 100 mili Henry, 1 Henry) 105 capacitance box(1 nano Farad, 10 nano Farad, 100 nano Farad, 1 micro Farad, 10 micro farad.) 106 Rheostat(50 ohm, 10 Amp) 107 Rheostat(250 ohm, 2.5 Amp) 108 Rheostat(100 ohm , 5 Amp) 109 APFC panel(440 V, 180 A, 3ph Panel) 110 Kit to determine phase difference between voltage and current in series R-Land R-Ccircuits.(trainer kit) 111 Tachometer(5 digit LCD display to max 99999) 112 single Phase Transformer(1 KVA, 230/115V with all terminals boughtout for connections) 113 Isolation Transformer(220V / 220 V, 1 KVA) 114 Pulse Transformer(220 V , 100 W, 1ph Induction mpotor ) 115 3ph Transformer(3-phase, 1KVA, 415V/230V, transformer with provision for the external connection terminals to perform all vector groups (star-delta,delta-star etc.)) 116 3-ph Auto Transformer(415 V, 3ph, 20 hp.) 117 3ph Resistance Box(upto 415 V, 20 Amp) 118 1ph - Motor for Ceiling Fan(220 V , 100 W, 1ph Induction mpotor ) 119 Universal Motor (2000 RPM, 220 V) 120 Stepper MotoR Control Circuit with Stepper Motor(5 Amp, 220 V) 121 AC Servo Motor with control circuit(3000 RPM, 440V, 3PH) 122 DC Servo Motor with control circuit(3000 RPM, 440V, 3PH) 123 BuckChopper with Control panel(220 V, DC, 5 HP power rating) 124 BoostChopper with Control panel(220 V, DC, 5 HP power rating) 125 Ardino Uno R3 (Clock Speed 48 MHz, Flash Memory - 256 KB, SRAM - 32 KB, EEPROM - 8 KB) 126 Motor Driver L293D(4.5 V TO 36 V, 1 Amp) 127 pyranometer WITH SHADING RING FACILITY(Pyranometer with Shading ring facility:- Response time (95%) - < 1s, -Directional error (up to 80 ° with 1000 W/m2 beam) - < 10 W/m2, - Temperature dependence (-30 °c to +70 °c) - -0.15%/ °c, - Sensitivity – 60 to 100 µ v/W/m2, Impedance–50Ω, -Spectral range (50% points) – 400 to 1100 nm, -Typical signal output for atmospheric applications – 0 to 100 mV, -Maximum irradiance – 2000 W/m2, -Detector – Silicon photo-diode.One revolving platform for irradiance measurement at different tilt angle with Pyranometer fixing.Instruction manual and Commissioning of the instrument is included.) 128 radiation meter(Model no RN 2104) 129 solar cell characteristics apparatus(Complete set up of Poly crystalline silicon PV Cell with facility to measure the cell parameters – O.C. voltage (Voc), Short circuit current (Isc), Voltage-Current-Power at Maximum Power point (Vmp, Imp, Mpp), Fill factor, Efficiency and draw I-V characteristics of cell.Set up components – Poly crystalline Solar Module (12V, 5Wp), holding structure, Controller (12V, 5Wp), Halogen Lamp and holding structure with variable light intensity on cell and temperature measurement facility of cell, Battery, Necessary Voltmeter, Ammeter, Electrical Load, Wiring and cabling. Installation & commissioning of set up is included.) 130 Solar flat plate collector(One piece 100 LPD Flat plate collector with complete set up and measuring facility of temperature, flow, pressure, thermal efficiency. We have mentioned system specification; the specification of individual component should be given for evaluation purpose.) 131 Complete set up of 40 Watt, 12 V DC solar street lighting system for student demonstration. Necessary components with installation are required.(Supply of Polycrystalline solar PV Module - 75 Wp under STC;Rechargeable Battery - Minimum 12.8V, 30 AH capacity Lithium Ferro Phosphate battery with required MPPT Solar Charge Controller cum Inverter;Light Source - White light emitting diode (W-LED) 18 Watt, W-LED luminaire. Pole height 2.5 m adjustable above the ground level. The set up should be suitable for students’ demonstration.) 132 inverter, (12 V DC) 133 charge controller(12.5 V , 20 A) 134 ELCB, (Upto 30 mA) 135 MCCB, (415 V AC, 16 Amp) 136 RCCB(Upto 30 mA) 137 i) ACSR(.3m) 138 ii)Cu(.3m) 139 iii)Al(.3m) 140 iv)Galvanized Steel(.3m) 141 v)Cadmium Copper(.3m) 142 vi)AAC(.3m) 143 vii)AAAC(.3m) 144 viii)ACAR(.3m) 145 i)Belted Cables(.3m) 146 a)Screened Cables - H-Type Cables(11kv,0.3m) 147 b) Screened Cables - S.L Type Cables(66kv,0.3m) 148 c)Screened Cables - H.S.L Type cables(66kv,0.3m) 149 a)Pressure Cables - Oilfilled Cables(66kv,0.3m) 150 b)Pressure Cables - Gas filled Cables(66kv,0.3m) 151 iv)XLPE Cables(0.3m) 152 v)PVC Cables(0.3) 153 vi)FRLS Cables(0.3) 154 a)Pintype - 11KV(procelain)/(polymer)(11kv) 155 b)Pintype - 33KV(procelain)/(polymer)(33kv) 156 ii)Disc Type with metal links(procelain)(11kv) 157 a)Disc Type11KV(polymer)(11kv) 158 a)Disc Type 33KV(polymer)(11kv) 159 iii)Shackle type(procelain)(230v) 160 D.C Network Analyzer (2-wired) 161 Distributor simulator using Power Transmission Trainer(trainer kit) 162 Digital Megger 250V,500V,1000V( 250V,500V,1000V) 163 PVC conduit1/2 inch,10ft(0.5 inch 10ft) 164 Schering bridge(trainer kit) 165 Anderson Bridge(trainer kit) 166 Kelvins Double Bridge(trainer kit) 167 Wheatstone Bridge(trainer kit) 168 i) SWITCHES - Float switch 250v sensor for water level(250v,6A) 169 ii)SWITCHES - Proximity switch(250v,6A) 170 iii)SWITCHES - Limit switch(250v,6A) 171 iv)SWITCHES - Push button switch(230v,6A) 172 v)SWITCHES - Pressure switch(Danfoss KP35)(23v,6A) 173 vi)SWITCHES - Thermostat (30 Amp)(230v,30A) 174 vii)SWITCHES - Electromagnetic relay (15Amp,250V)(250V,15A) 175 viii)SWITCHES - selector switch(230v,6A) 176 Infra red camera for therma imaging 32*32*pixel infrared sensor(Hand held thermal imager: Object Temperature Range: -20° to 550°C (-4° to 1022°F)Temperature Accuracy:  ±2°C (3.6°F) or 2% of reading (Environment temperature 10-35°C; Object temperature >0 C)Field of View (FoV)/Minimum Focus Distance: 56°x 42°/ 0.5mSpatial Resolution (IFoV): 3.75mRadImage Frequency: 25Hz Focus FreeZoom: 1-32x continuous, digital zoom Focal Length: 3.2mm Focal Plane Array (FPA)/Spectral Range: Uncooled microbolometer/8-14μm IR Resolution: 256×192 pixels Display: 3.5 in. LCD, 640×480 pixels TouchscreenImage Modes: Infrared Image, Visual Image, Picture in Picture, Auto-fusion, ZoomColour Palette: IRON, Rainbow, Grey, Grey Inverted, Brown, Blue-Red, Hot-Cold, Feather, Above Alarm, Below Alarm, Zone Alarm, Vision ZoneAutomatic Hot/Cold DetectionCenter Spot, Three manual spotsStorage Media: 8 GB MicroSD card and 3.4GB internal EMMCData transfer between camera and PC. Live video on camera and PC.Video Storage Standard MPEG-4 encode. 640×480 at 30fps, on memory cardSimultaneous storage of IR and visual imagesImage Storage Format Standard JPEG or HIR files including measurement data, on memory card >6000 picturesImage Storage Mode IR/visual imagesImage Analysis ToolsInterfaces: USB Type C and WiFiRechargeable Li-Ion battery, 4 hours operating timeAuto Power-off) 177 Projector(sony ) 178 Printer with Xerox cum Scanner(Epson) 179 Projector- screen(150 inch)
Contract Date: Jan 24, 2025 Contract Value : 13.89 Lakh
Government Departments No of Bidders 16
West Bengal View Result →
12.
Science and Technology #10291902 Price Bid
Tender For Civil Renovation Work Of Ccgm Building At Csir-Neeri, Nagpur; 1 Dismantling Gypsum/ aluminium/Wooden partitions , fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 2 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in charge. 3 In cement mortar 4 Dismantling of Indian type Water Closet along with flushing cystern / Europian type Water Closet/Urinals along with flushing cystern / Wash basin / Water Heater with all inlet & outlet puprline / Sintex Over Head Water Tanks at all floor level along with all fixturesof any size including stacking of useful materials in NEERI premisesand disposal of unserviceable materialswith all lead and lift as per direction of Engineer-in-charge: 5 Dismantlingoldplasterorskirtingrakingoutjointsandcleaningthe surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 6 Dismantlingall type of tile work in wall, floors and roofs laid in cement mortar including its base plaster, P.C.C. & stacking material within 50 metres lead. 7 For thickness of tiles 10 mm to 25 mm 8 Dismantling G.I. pipes (external , Internal & concealed)aftertakingoutthepipes,manually/bymechanicalmeans includingstackingofpipeswithin 50metres leadasperdirectionof Engineer-in-charge : 9 15 mm to 40 mm nominal bore 10 Dismantlingdoors,windowsandclerestory windows(steelorwood) shutterincludingchowkhats,architrave,holdfastsetc.completeand stacking within 50 metres lead : 11 Of area 3 sq. metres and below 12 Dismantlingold rain ,waste water C.I. pipesincludingexcavation if required andrefilling , takingoutthepipes,manually /bymechanicalmeansstacking of pipeswithinNEERIpremises with all lead as per the direction of Engineer-in-charge: 13 Up to 150 mm diameter 14 Demolishingcementconcretemanually/bymechanicalmeans including refiling and disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15 1:3:6 or richer mix 16 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 17 Removing dry or oil bound distemper, plastic emulsion, water proofing cement paint and oil paintby scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 18 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONALanti-termitetreatment(excludingthecostof chemical emulsion) : 19 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at45 degree and plugging them with cement mortar 1:2 (1 cement: 2 coarse sand) to the full depth of the hole 20 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 21 Supplying chemical emulsion in sealed containers including delivery as specified for post constructional anti-termite treatment. 22 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 23 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : 24 Cement mortar 1:4 (1 cement : 4 coarse sand) 25 12mm cement plaster of mix: 26 1:4 (1 cement: 4 fine sand) 27 Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing: 28 1:2:4(1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size) 29 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- 30 All kinds of soil 31 Supplying and laying boulder soling (soling stone 125 to 45 mm)and voids filled withmurum below floor and plinth including wateringcompacting and consolidating in layer not more than 150mm thick etc. complete 32 Providingandfixing15-18 mmthickgangsawcutmirrorpolishedand prepolished machine cut of any colourshade and size for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement cement,mixedwithmatchingpigment,epoxytouchups, including rubbing, curing and polishing, edge full moulding on both sideor wherever necessarry as per drawingand instruction of Engineer Incharge etc. complete at all levels. 33 Granite of any colour and shade 34 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete. 35 Providing and fixing 1st quality ceramic glazedtiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approvedmake in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqmincluding pointing in white cement mixed with pigment of matching shadecomplete. 36 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer,in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average6 mm thickness, including grouting of joints.( Matt/Antiskid) 37 Vitrified tiles of size 800x800mm 38 Providing and laying Vitrified tiles in different sizes (thickness to bespecified by anufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, Dado over on cement based high polymermodified quick-set tile adhesive (Water based) conforming to IS: 15477 in average 6mm thickness including grouting the joint with white cement & matching pigments etc. complete. 39 Vitrified tiles of size 800x800mm 40 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws . 41 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) 42 Providing&Fixingdecorativehighpressurelaminatedsheetofplain/ woodgrainingloss/matt/suedefinishwithhighdensityprotective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality 43 1.0 mm thick. 44 Providing and fixing aluminium work for windows and ventilators with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 45 For fixed portion: including Powdercoatedaluminium (minimumthicknessofpowder coating 50 micron) shade as approved by the Engineer in charge. 46 Forshutters: ofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixingoffittingswhereverrequiredincludingthecostof PVC / neoprene gasket required (Fittings shall be paid for separately) including Powdercoatedaluminium(minimumthicknessofpowder coating 50 micron)shade as approved by the Engineer in charge. 47 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality and including all fitting and fixtures, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately. 48 Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. 49 Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). 50 Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. 51 Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x (85mm & above) & French (False) mullion (55 mm & above) x (60mm & above). (Height upto 2.5 metre). 52 Fixed window / ventilator/ parition with mullion / transom. 53 Using R3 series with frame (55mm& above ) x (45mm& above) & mullion (55mm & above) x (65mm & above). (Height upto 2.5metre) 54 Providing & fixing 65mm thick full ht. Dead partition with 8mm thick cement board (fire resitance paramiter as per BS 476- Part 22 with resistance of 134 min. or Equivalent) to either side of frame of 50 mm x 50 mm x 1mm Aluminium sections at less than 610 mm c/c. Including 65mm thk. Including Wicket gate with all necessary fittings & 15-19 mm thick black granite strip, with half round poilshed edge fixed with necessary adhesive on partition edges as per drawing. The item also includes grouting frame in floor etc. complete.As per drawing. 55 Providing & preparing Laboratory platform 600-800 mm wide out of 16 mm thk. Black granite supported over 12 mm thk. Cement Board including double moulding on the edges, with 25 x 50 mm size Aluminium hollow pipes (TW inserted) for framing etc. complete. 15 mm thk. PVC Panel shutters shall be screwed to Al. framework, via hinges. Intermediates shelves & pull-out working tray operating on telescopic channels shall be out of 15 mm thk. PVC panel. Necessary hardware like S.S. Handles, magnets, locks, etc. shall be considered. All edges shall be finished with 10mm thk.t.w. beadings. All beadings shall have 03 coats of acrylic emulsion paint after relevant coat of wood primer, with finishing etc. complete. (All Hardware-Ebco or equivalent make) 56 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per therchitectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 57 With float glass panes of 5 mm thickness 58 Providing and fixing stainless steel grade 304 mosquito net/wire gauze of average width of aperture 1.2-1.4mm with wire of 26 gauge mm with powder coated suitable aluminimum section (8X18 mm), 1.2mm th. fordoors,windowsin aluminium window etc. complete of make as approved by the Engineer in charge. 59 Providingandfixingaluminium/SSslidingdoorboltsISImarkedanodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 60 300x16 mm 61 Providingandfixingaluminium/SSslidingdoorboltsISImarkedanodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 62 125 mm 63 Providingandfixingaluminium/SShangingfloordoorstopperISImarked anodised (anodiccoating not lessthan gradeAC10asperIS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 64 Twin rubber stopper 65 Providing and fixing aluminium/SS tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 66 250x10mm 67 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS:3564 embossed on the body, door weight 36 kg to 80kg and door width 701mm to 1000mm) (make- Godrej or as approved) with double speed adjustment with necessary accessories and screws etc. complete. 68 Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction ofEngineer-in-charge complete. Upto 5mm depth and 5 mm width 69 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 70 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications including scafolding : 71 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm 72 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 73 Two or more coats on new work 74 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 75 In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works 76 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 77 Providing & Fixing 15mm C.P. brass Concealedstop cockwith protection cap(CON-083FTK of Jaquar) with exposed part kit of concealed stop cock with fitting sleeve, operating lever and adjustable wall flange with seal(CON-083FTK) , washer complete, including cutting & making good the wall wherever required. As per list of approved make or Equivalent or as directed by Engineer Incharge 78 Providing and fixing white vitreous china wall hung wash basin 460x415x200m aprox (Model -CNS-WHT-305 of jaquar) with half pedestal wall Hung basin with fixing accessories andfittings / bracket including 15mmC.P brass Pillarcock auto closing system(Jaquar-PRS-031 or equivalent ), C.P Bottle Trap Casted Heavy(Jaquar-ALD769L 250/300X190 or equivalent),32mm C.P. brass waste coupling(Jaquar-ALD705 80mm height or equivalent)full thread, brass angularstop cock with wall flange(CON-059KN), CP copper connecting pipe 450mm( ALD-805B) includingcutting and making good the walls wherever required etc. Complete as per the instruction of Engineer incharge. 79 Providing and fixing vitreous china rimless wall hung WC with UF soft closing slim seat cover, hinges, accessories set (CNS-WHT-963UFSM) with allfittings &wall hung cistern with 39mm L bend drainage& extension pipe withgasket & O-ring & instalaltion kit ( top cover with ledge(ESH-WHT-184AN of jaquar essco) with installation of complete, brass angularstop cock with wall flange(CON-059KN), CP copper connecting pipe 450mm( ALD-805B) etc complete cutting and making good the walls and floors wherever required as per approved make of Jaquar or approved equivalent make. The approved make like Jaquar/Kohler make. Size 380x515x360mm 80 Providing and fixing 630x445mm Swivel Mirror (AKP-35795 of jaquar) for wash basin rectangular shape for gents and ladies toilet from approved make such as Jaquar/Kolhar/Roca having beveled edge with required fixtures such as bracket and screws etc. complete as per the direction of Engineer-in-charge. 81 Providing and fixing C.P brass Quarter turn two way Bib cockwith wall flange(CON-041KN of jaquar) ofapproved make as per the instruction of Engineer-In-charge. 15 mm nominal bore. 82 Providing and fixing health faucet(jetspray)( ALD 573 of jaquar) of 8mm dia. 1 meter long flexible tube and hook ofapproved make as per the instruction of Engineer-In-charge. 83 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including paintingwith anti corrosive bitumastic paint, cutting chases and making good the wall etc. 84 15 mm nominal outer dia Pipes 85 Providing and fixing G.I. pipes complete with G.I. fittings and clamp including cutting and good the wall etc 86 25 mm nominal outer dia Pipes 87 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 88 25 mm nominal bore 89 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 90 25 mm nominal bore 91 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 92 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 93 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 94 25 to 40 mm nominal bore 95 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 96 For pipes 100 to 250 mm diameter 97 Providing and fixing on wall face/floor with clips unplasticised - PVC (SWR type A,working pressure 4 Kgf per sq cm )pipes conforming toIS: 13592 includingall fittings like Tee, Bend,cleaning type,Y etc.conforming toIS: 14735,scafolding & jointing with sealring/ solvent cement and testing of joints complete, conformingtoIS: 5382 leavinggap for thermal expansionof make Supreme/Kissan classic/Prince as approved by the Engineer in charge. 98 Single socketed pipes 110 mm diameter 99 Single socketed pipes40mm diameter 100 Single socketed pipes 75mm diameter 101 Providing and fixing on floor110x75mm PVC(SWR)Nahani trap conforming toISof makeas approved by the Engineer in charge. 102 Providing and fixing stainless steel jali (grating) with or without hole for waste pipe for floor/ nahani trap. 103 110mm dia 104 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 105 Inside dimensions 600x 850 mm and 45 cm to 60cm deep for pipe line with three or more inlets : 106 With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 107 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 108 Size 600x450x200 mm 109 Bench/wall Mounted 3 Way swan neck Column With Swiveling Spout, Water Flow Around 40i/min At 3 Bars Pressure, Surface Protection:epoxy Powder Coating Ral 7035 Materials:brass / Handle In Pp Head work Sealing. 110 Removing and refixing exisitng false ceiling frame and sheet with necessary fitting and fixtures and framing work without damaging the sheet as instruction ofEnginner incharge etc. complete 111 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 112 In 75x75 mm deep chase 113 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open groove for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawing for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations 114 and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation including the cost of aluminium frame work with minimum 1.2mm thick aluminium sections for ACP cladding. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 115 Providing and fixing vertical blinds with 100mm Louver width, quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with Acrylic coating resistance to Cracking & Fraying and treated for dust repellency, UV proof , virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom weight - 116.20mmX48.30mm and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete as directed by engineer incharge. 116 Providing and fixing precoated galvanized iron profile sheets(size, shape and pitch of corrugation as5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in approved by Engineer-in-charge) 0.05 mm. 240 mpa mm steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 117 Providingandfixingprecoatedgalvanisedsteelsheetroofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsmasperIS:277in240mpasteelgrade,5-7micronsepoxy primer on both side of the sheet and polyester top coat 15-18 microns usingselfdrilling/selftapping screwsorwithpolymer coatedJorL hooks, bolts and nuts andorG.I. seam bolts andnuts,G.I. plainand bitumen washers complete : 118 Gutter .(600 mm over all girth) 119 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 120 Providing JCBincluding driver, helper and fuels chargesfor loading and unloading any type of road material debrises including filling, levelling the ground,cleaning in any area like jungle, broken branches of trees, debrises of institute campus etc. complete as per the direction of Engineer-in-charge. 121 Providing Tipper/ truck includingDriver, helper and Fuels charges for cleaningof debrises/malba, soil, wooden logs, dried trees, shifting construction material, sand, road material and shiftfrom one place to another place in NEERI campus including loading and unloading as per the direction of engineer-in-charge .
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
13.
Housing Urban and Rular Development #10191469 AOC
Furnishing Work Of Classrooms, Library And Laboratory, Equipments And Miscellaneous Work For The New University Campus Of Binod Bihari Mahato Koyalanchal University, Dhanbad- 1 Supplying Metal Exhaust Fan 300 mm Sweep-Supplying, erecting and testing of approved make 300 mm sweep Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including frame bolt/ Anchor hole fastners etc, complete finished of a as required. 2 Wall Demolition- Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 3 Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 4 Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 5 Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. 6 Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. 7 Door Frame- Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile C - Fixing with adjustable lugs with split end tail to each jamb 8 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. 9 Extra for providing and placing in position 2 Nos 6mm dia. M.S. barsat every third course of half brick masonry. 10 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. 11 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 12 Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. 13 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.-Granite stone slab colour black, Cherry/Ruby red-Area of slab over 0.50 sqm 14 Sink- Supplying fitting and fixing white glazed fires clay sink of approved make with overflow arrangements supported on C.I. Or R.S. Painted bracket 40mm. Dia C.P. Brass waste with C.P. Brass chain and rubber plug 40mm dia P.V.C. Waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams including cutting wall and making good the same etc. all complete as per specification and direction of E/I. Size-600 mm x 450 mm x 250 mm ) 15 FULL HEIGHT WOODEN PARTITION WITH PARTLY GLAZING- Providing and fixing partitions made of 50 mm x 50 mm pine wood / 2nd class teak wood @ 600 mm c/c both ways with the help of Fasteners/Screws etc. to achieve desired strength. Providing & fixing Comm. grade 12 mm thick commercial Pty board on the frame on both the faces i/c exposed side edges of Frame & 1.0mm thk Laminate on both outer faces and exposed side edges of ply as per the directions. Partition shall also be provided with 8 mm thick clear float glass of approved size with Polished Edges of approved brands in Wooden Partition Openings as required, fixed from all four sides from both ways inside partition openings with 10mm.tk. T.W. beadings/12 mm thick MDF Board Lipping/D-Buttons of design as per approval and direction at site. Etching / Etching Film (50 Microns) is to be provided as per approved pattern on 8 mm thick clear float glass. All wooden exposed surfaces shall be melamine polished in approved shade and texture finished as per the directions and satisfaction of Engineer In charge, compelete.This work will 16 Frosted glass sheet of nominal thickness 4 mm- Providing and pasting frosted film on glass work including all materials tools, plants and labour complete as per the directions of the Engineer-in-charge. 17 Supply & laying of PVC insulated and sheathed 1.1 kv grade twin twisted 1.5 sqmm cu flexible wire for speaker. 18 Providing & installation 1.5 Tr. 5 Star split A.C (Inverter Type) I91391-part-1 19 Copper refregerant pipe-Providing & installation Copper Tube of size 5/8 for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation 20 Providing & installation 5 KVA wall mounted automatic voltage stablizer from range 140 V to 280V 21 Providing & installation Drain Pipe for AC 22 Non Schedule 23 * PROVIDING AND SUPPLYING MODERN DESIGN RECEPTION DESK IN ENGINEERED WOOD MAKE THE PRODUCTS UTILE AND A DELIGHT.TIMELESS DESIGN THAT ELEVATES YOUR OFFICE SPACE STRUCTURE OF SPACIOUS RECEPTION DESK,TABLETOP OFFERS YOU A GENEROUS LOOK FOR WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 1800 MM(L)X 600 MM(D)X 750 MM(H) WHICH GIVE MORE SURFACE AREA FOR WORK ,TABLE TOP MADE OF25MM THICK ALSO TABLE TOP BASED ON SIDE PANELS MADE 18MM THICK PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST. * COMBINATION CONSTRUCTION OF RECEPTION DESK ABOVE TABLE TOP 18 MM THICK COUNTER TOP TO TABLE TOP HEIGHT IS @ 300MM ,OVERALL RECEPTION DESK HEIGHT IS @ 1050MM WITH COUNTER TOP,TABLE TOP MADE 25 MM THICK PRELAM PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK PVC EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXED WITH HOT MELT GLUE.ALONG WITH 18MM THK ADDITIONAL MODESTY PANEL SIZE IS 1350 MM (L) X 700 MM (H) MADE BY EXCLUSIVE FROSTY WHITE COLOUR WITH EPIC DESIGN & LOOK.1 MOBILEPEDESTAL (2 DRAWERS + 1 FILING CABINET )SIZE IS 450 MM(L)X 450 MM(D)X 725 MM(H) IN PROVIDED WITH CENTRAL LOCKS FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING & PEDESTALS MOVE ON NYLON CASTORS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST 24 PROVIDING AND SUPPLYING * MEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 580MM(L)X 670MM(D)X1110MM(H) ,*THE CHAIR MADE OF FULL UPHOLSTERY IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : AMREST IS HAVING TWO ADJUSTMENT HEIGHTS (UP & DOWN) .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM. SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 480MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1110MM & MINIMUM HEIGHT IS1010MM* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650MM NYLON BASE WITH SMOOTH CASTORS . 25 PROVIDING AND SUPPLYING 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION,THREE SEATERTYPE WAITING AREA CHAIR - MATERIAL : STAINLESS STEEL SIZE 1820MM(L)X 690MM(D)X 790MM(H) COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 26 Supplying of Portrait/Landscape Not applicable Fabric Pin Up Notice Boards(Fabric Pin Up Notice Boards 3 X 6 FT GREEN),Specification-Width of Board in mm:900 mm,Colour(Front/ Display layer):Green,Height of Board in mm:1800mm,Rear panel material of Board:Laminated sheet,Overall pinability depth ofBoard in mm:9 millimeter,Core material thickness inmm:9 millimeter 27 PROVIDING AND SUPPLYING COLLEGE DESK TOMKINS MATERIAL : PRELAMINATED PARTICLE BOARD WITH M.S BASE UNIT SIZE : 590 MM(L) X 1090 MM(D) X 830 MM(H) PER SEAT SIZE- 590 MM X 375 MM X 450 MM/ONE SEATER DESK SIZE :1090 MM(L) X830 MM(H) COLOUR : AVAILABLE ON REQUEST/FINISH : EPOXY POLYESTER ,* PROVIDING & SUPPLYING TWO SEATER COLLEGE DESK TOMKINS COMBINATION OF THREE ROWS FIRST , MIDDLE AND LAST SCRATCHPROOF EASY WIPE TOP / DURABLE ,STRONG & SAFE,UNDERSTRACTURE MADE OF MAIN FRAME MDE OF CRCA POWDER COATED IS GRAD:304 M.S BLACK POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) EPOXY POLYESTER COATING.* TABLE TOP & MODESTY PANNEL MADE IN 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS.CHAIR WITH GAS LIFT ,A). BACK FRAME: 1.2MM COLD ROLLED STEEL/B). BACK BOARD: 10MM PLYWOOD, NO CUSHION C). SEAT BOARD: 15MM PLYWOOD, NO CUSHION/D). TIP-UP SYSTEM: SPRING MECHANISM E). 2. LEG: COLD-ROLLED STEEL, FIXING ON THE FLOOR BY SCREWS, 80 X 35 X 1.5MM THICK OVAL TUBE, BLACK POWDER SPRAYING.* THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST 28 Supplying of Material & Subtype Engineered Wood Table Top Material Engineered Wood Finish Matte Colour & Colour Family Brown - Classic Walnut Dimension (W)550mm X (D)550mm X (H)1200mm Size Compact Assembly Type Knock Down (Obelisk), 29 Suppling of Writing Board ( 4x10 Non-Magnetic) of material Top Surface materials (Used for white boardsurface)-Porcelain,Top surface material thickness -0.7 mm to 0.8 mm,Frame material -Anodized extruded aluminum alloy hollow section conforming to IS 733 (With latest amendment),Frame wall thickness-1.2 mm,Frame section front -20 mm,Frame section side -16 mm,Core material-MDF board grade-I conforming to IS 12406 (with latest amendment),Core material thickness -9 mm as per Department incharge 30 Supplying of 14 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 8850 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 8850 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST, * CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST, 31 Supplying of * HIGH BACK 360° DEGRE REVOLVING CHAIR SKU : MARVEL/HB/ECO ,* ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1380MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM . * ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) , SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1380MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 32 Supplying ofMEDIUM BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 595MM(L)X 670MM(D)X1125MM(H) ,*THE CHAIR MADE OF FULL MESH IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH ABOUT STYLE TYPE IS MODREN.DETAILS :* * ARMS : FIXED PP ARMSREST .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT).* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK :FRAME OF DESIGN SHALLBE CURVEDMADE OF TWO PIECES INJECTION MOULDED FRAME COVER WITH MESH .BACKREST SUPPORTADJUSTABLE LUMBAR SUPPORT* MECHANISM : SINGLE LOCKING MECHANISM .* ONLY SEAT SIZE IS 670MM(L)X 595MM(D)X470-570MM(H) ,SEAT MAXIMUM HEIGHT IS 570MM & MINIMUM HEIGHT IS 470MM & BACK MAX HEIGHT IS @ 1125MM .* GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : NYLON BASE IS 620MM PITCH CENTER DIA (660MM WITH CASTORS) . 33 Supplying of Tte Mild Steel Pipe of diameter 19 mm and wall thickness 16gauge. Classroom Chairs, tte,Thickness-2mm to 45mm,Material-Mild Steel Weight-Depends upon the size,Outside Diameter-0.80 Inch to 36 Inch 34 Supplying of 1-Bay Sprocket Chain Drive Mechanism MobileStorage Compactors,Material-Mild Steel Product Type-1 Bay,Height -7 ft,Storage Capacity-50-80 kg Usage/Application office, Home, Hospital, Store Room, Warehouse 35 Supplying of -- Movable File StorageSystem (Compactor) 1-Bay Mechnized Drive Type(COMPACTOR 2 ( 04 BODY)) 36 Supplying of Methodex MS1-6MCMETHODEX(Methodex MS1-6MC),Accutec Mobile Storage System,Material SS,Usage/Application-Warehouse Height-8-10 Feet,No of Layers-5 37 Supplying of : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 38 Supplying of : PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK . * PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 39 Supplying of* HIGH BACK 360° DEGRE REVOLVING CHAIR * ALL OVER SIZE IS : 590MM(L)X 505MM(D)X1280MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING . * USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * MECHANISM : KNEE TILT MECHANISM . * ONLY SEAT SIZE IS 505MM(L)X 505MM(D)X610MM(H) & THE BACK SIZE IS 590MM(L)X 710MM(H) SEAT MAXIMUM HEIGHT IS 610MM & MINIMUM HEIGHT IS 510MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1280MM & MINIMUM HEIGHT IS1180MM * GAS LIFT 100 MM TELESCOPIC HAUDRAULIC * BASE : 650 MM CHROME BASE WITH SMOOTH CASTORS . 40 Supplying of* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 570MM(L)X 500MM(D)X940MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE . DETAILS : * ARMS : PADDED ARMREST. * USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED. * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT * ONLY SEAT SIZE IS 570MM(L)X 500MM(D)X475MM(H) SEAT HEIGHT IS @ 940MM & BACK HEIGHT IS @ 475MM . * FIXED CANTILEVER CHAIR . * BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 41 * SUPPLYING AND PLACING FIVE SEATER (3+1+1) EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 3 SEATER- 1905MM(L) X890MM(D)X 870MM(H)SOFA SIZE IS 1 SEATER -(W)960mm X (D)890mm X (H)870mm ,WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME. * COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 28 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 50MM THIK,40MM THICK BACK FOAM HAVING 20 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 20 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BLACK-EERIE BLACK-COFFEE BROWN,BROWN-BURNT UMBER COLOUR, IT COMPLEMENTS THE MODISH LEGS ARE MADE BY ROUND SHAPE IN PVC MATERIAL. 42 Supplying of Material & Subtype Solid Wood - Beech Wood Table Top Material Clear Glass,Frame Material Solid Wood Leg Material Solid Wood,Finish Matte Colour & Colour Family Brown - Walnut,Dimension (W)1130mm X (D)630mm X (H)410mm,Number Of Recliners 1 Number Of Reclining Positions 3,Size Standard (HOPPER/CT), 43 Supplying of6 SEATER Rectangular MEETING TABLE DURIAN MODEL SMART/CON/6FT MADE OF PRELAMINATED PARTICLE BOARD WITHSLANTLEGS50X50 MM MS UNDERSTRUCTURE IN POWDER COATING 2TOP MADE OF25MMTHICK PRELAMINATED PARTICLE BOARD IN FROSTY WHITE COLOR WITH MAIN TABLE SIZE1800MM(L)X 1050MM(D)X 750MM(H) (SMART/CON/6FT/A), 44 SUPPLYING & PROVIDING CAFETERIA CHAIR SIZE IS 381MM(L)X 419MM(D)X839MM(H) A COMBINATION OF SYNTHETIC FIBER WITH STAINLESS STEEL MAKE THE PRODUCTS UTILE AND A DELIGHT, THE COMPLETE STRUCTURE SHALL BE MADE UP OF 20% GLASS FILLED BLOW MOLDED HIGH-DENSITY POLYETHYLENE ANDIS,THE FRAME STRUCTURE SHALL BE SUPPORTED BY ( 2 STRAIGHT + 2 SLANT ) FOUR LEGS.THE TUBULAR WELDED FRAME IS MADE FROM DIA2.22 +/- 0.03CMX 0.12+/- 0.0128 CM AND 3.5+/- 0.03 CM X 0.12+/- 0.0128 AM STAINLESS STEEL 202 GRADE TUBE & THE TUBE ARE BUFF POLISHED TO GIVE SHINY FINISH.SEAT AND IN BACK GIVEN HANDLE TO HOLDARE MADE OF INJECTION MOULDED HIGH IMPACT STRENGTH POLYPROPYLENE POLYMER COMPOUND WITH INDOOR GRADE UV RESISTANCE AND PRESSED FITTED WITH LEGS.THE CHAIR IS EASY TO STORE WHEN NOT IN USE, SINCE YOU CAN STACK UP TO 6 CHAIRS ON TOP OF EACH OTHER. (COCO/SUR). 45 SUPPLING OF METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1830MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET.HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, FITTED WITH MS BODY LOCK & HANDLE. WITH 2 NUMBERS OF GLASS DOOR SHUTTERS , THE GLASS USED SHALL BE 4MM THICK CLEAR. UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 30 KG MAXIMUM.EACHRACKSHALLBEPROVIDEDWITHSTIFFENERATBOTTOMFOR STRENGTH.THE ENTIREBODYPANELAND SHELF SHALLBEMADEOF HIGHYIELD STRENGTH,THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY 46 SUPPLING OF DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 750MM(D)X 750MM(H) 36MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITHWENGE FINISH, USING HOT MELT GLUE TO FIXING 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 25MM THICK.*PROVISION OF SIDE RUNNER OF SIZE IS 750MM(L)X 450MM(D)X 760MM(H) ,( CONSTRUCTION IS FROM RIGHT SIDE OF SIDE UNIT TOP BASED ON FIXED PEDESTAL WITH SS STUD OF GRADE 304, ON TABLE TOP PVC GROMENT HOLEFOR WIRE MANAGEMENT .*FIXED PEDESTAL OF SIZE450MM(L)X 450MM(D)X 650MM(H) PER DRAWER HEIGHT IS @ 136MM, FILLING DRAWER HEIGHT IS @ 300MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 47 SUPPLING OF* CANTILEVER CHAIR SKU : 70011/CN/A, * ALL OVER SIZE IS : 590MM(L)X 490MM(D)X980MM(H) , *THE CHAIR MADE OF FULL FABRIC INBLACK COLOUR . IT WILL COMES INFINSIH IN CONTEMPORARY STYLE . DETAILS :* ARMS : FIXED ARMS P.P. CONNECTED WITH SEAT AND BACK .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32(±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* BASE : M.S POWDER COATED TUBLAR FRAME OF CATILEVER TYPE . THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. 48 SUPPLING OF OFFICE DESKDESK STRUCTURE OF L SHAPED DESK . PRIMARY WORK SURFACE OVER ALL SIZE IS 1500MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL 18MADE OF MM THICK . *PROVISION OF SIDE UNIT OF SIZE IS 900MM(L)X 450MM(D)X 750MM(H) ,(COMBINATION CONSTRUCTION WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP, LEFT SIDE TABLE TOP BASED ON A 18MM THICK SIDE PANNEL ENGINEERED WOOD & FROM RIGHT SIDE UNIT HAVE 2 SLIDING DOOR + 1 FIXED SHELVE . *SIDE UNIT SIZE900MM(L)X 450MM(D)X 750MM(H), IN PROVIDED WITH LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF SIDE UNIT IS 18MM THICK ALONG WITH FECIA OF SLIDDING SHUTTERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST . 49 SUPPLING OF * FIX CANTILEVER ,* ALL OVER SIZE IS : 595MM(L)X 510MM(D)X875MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 500MM(L)X 510MM(D)X455 MM(H) & THE BACK SIZE IS 440MM(L)X 595MM(H) , BACK HEIGHT IS @ 440MM .* BASE : 4 LEGS METAL POWDER COATED* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 50 * PROVIDING AND SUPPLYING PENTA WORKSTATIONLSHAPE SINGLE SEATER UNIT NON SHARING IN COMPLETELY KNOCK DOWN CONDITIONS WITH AN OVERALL SIZE 1500MM(L)X 600MM(D)X 1200MM(H) THAT IS TO BE ASSEMBLED AT SITE. THE WORKTOPSHALLHAVETHESIZE1490MM-1490MM (L) x 592(D) MADEUPOF25MMTHICKPRE- LAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST . OF IS LEVEL WITH APPROVED LAMINATE AND FINISH AS PER APPROVED SHADE. * THE PROFILE OF THE TOP SHALL BE IN RECTANGLE SHAPE AND THE EDGES SHALL BE SEALEDWITH 2MM THICK THIN STRIP OF IMPERMEABLEPVCTHAT IS CUT TO FIT THE SIZE OF BOARD PANEL AND DULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THE TOP TRIM, TOP BAR, MID BAR, VERTICAL BAR, RACEWAY, SKIRTING SHALL BE MADE UP OF ALUMINIUM EXTRUSIONS (PRE-TREATED)AND DULY POWDER COATED WITH POLYESTER POWDER COATING 40P-60PTHICK . THE TRIMS SHALL HAVE THE SIZE 67MM X 19MM WITH 1.5MMTHICKCOVERED WITH DIE CAST END CAPS ON JOINTS 2 WAYS,3 WAYS& 4 WAYS(L-COVERFORCORNER,T-COVERFORMIDDLESECTIONWHEREVER REQUIRED).THEALUMINIUMRACEWAYSHALLBESITUATEDBELOWTHEWORKTOPWITHAN OVERALLSIZE149MM(H)X60MM(D)WITH1.4MMCOVERTHICKNESSAND2MMBACK THICKNESS AS PER REQUIREMENT OF INLAYING THE ELECTRICAL MANAGEMENT AND CARRYING THE WIRE HORIZONTALLY. *THE EXPOSED VERTICAL AND HORIZONTALFACES OF THE FRAMES SHALL BE SNAPFITTEDWITHTRIMS.THERESHALLBESOFT-BOARD(WITHFABRIC)ANDMARKERBOARD PROVIDED AT FRONT OF THE USER. LAMINATED TOP TILE AND BOTTOM TILE SHALL BE SITUATED AT BOTH SIDES OF THE USER AND BELOW THE WORK TOP RESPECTIVELY. THE PARTITION SHALL HAVE CONCEALED WIRE MANAGEMENT CAPABILITIES AND SHOULD BE ENGAGED FOR RESPONSIVE AND SAFE OPERATIONSOF POWER,TELECOMMUNICATIONSANDDATA(LAN)AND HASSEPARATE COMPONENTS FOR ELECTRICAL, DATA AND TELEPHONE CABLES HAVING ADEQUATE CAPABILITY OF BOTH THE VERTICAL AND HORIZONTAL WIRE MOVEMENTS.SLOTS/CUT-OUTS SHOULD BE GIVEN ON RACEWAYSTOFIXALLELECTRICALANDDATAPOINTS.SINGLESIDEDPVCWIRE MANAGER SHOULDBE ENCLOSEDATTABLETOP.ADJUSTABLE LEVELLERSHOE SHALL BE PROVIDED AT BOTTOM OF THE PARTITION TO AVOID SCRATCHESON THE FLOOR.PARTICLE BOARD OF GRADE II OFISLEVEL. * THREE LAYER PRELAMINATED PARTICLES BOARD (WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST .* THE SELLER / COMPANY SHOULD BE ISO 9001:2015, ISO 50001:2018, ISO 14001:2015, ISO 45001:2018 CERTIFICATES OF THE MANUFACTURER CERTIFIED BY NATIONAL ACCREDITATION BOARD OF CERTIFYING BODIES, IGBC, SEDEX, GREEN PRO, AIOTA, INDIAN DESIGN MARK, FSC CERTIFICATE. THE BIDDER SHOULD BE A MEMBER OF BIFMA AND AT LEAST TWO PRODUCTS OF THE OEM SHOULD BE CERTIFIED AS BIFMA COMPLIANT AND AN OFFICIAL PRODUCT OFFICIAL LINK/SCREENSHOT OF THE PRODUCT LISTING MUST BE PROVIDED FROM WWW.BIFMA.ORG WARRANTY-5 YEARS MAKE-DURIAN /GODREJ/FEATHERLITE 51 PROVIDING & SUPPLYINGFIXING OF TWO SEATER SCHOOL DESK WITH SHELF/STORAGE UNDER DESK WHICH ONE MADE BY CAST IRON,DESK TOP MADE BY 18MM THICK PRELAMINATED PARTICAL BOARD OF GRADE II TYPE III OF IS 12823/LATEST,TWO SEATER CLASSROOM DESK CUM BENCH, TOTAL SIZE OF BENCH : 1050MM(L)X 950MM(D)X 760MM(H) DESK SIZE : 1050MM (W) X 400MM (D) X 760MM (H) BENCH SIZE : 1050MM (W) X 310MM (D) X 390 / 760MM (H) BACK SIZE : 1050MM (W) X 150 MM (H),TABLE TOP SHALL BE POLYPROPYLENE CO POLYMER (PPCP).BANDING UNDER STRUCTURE-BLACK 9005 ERW PIPE (AS PER IS:7138) : 25X25X1.2MM SQUARE MS PIPE, OF THICKNESS 1.2MM IN BLACK EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON) AT BASE WITH PLASTIC CAPS MADE OF PP COPOLYMER (3530 GRADE) ARE ALSO PROVIDED ON THE REAR FRAMES ADDING MORE AESTHETIC VALUE TO THE PRODUCT. * ADDITIONAL HORIZONTAL SUPPORTS OF M.S. C SECTIONS OF 1.5MM THICK ARE PROVIDED BELOW THE DESK & SEAT.SHELF: 0.8MM THICK POWDER COATED M.S. SHEET BELOW THE DESK & HOOKS ON EITHER SIDE OF DESK IN M.S. ROD OF DIA 6MM.TOP,SEAT AND BACK PANEL: 18MM THICK PRE LAMINATED BOARD WITH MACHINE PRESSED EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE FIXEDDULY PASTED WITH THE ASSISTANCE OF EDGE BANDING MACHINE AT 200 DEGREE CELSIUS. * THREE LAYER PRELAMINATED PARTICLES BOARD ( WOOD PRODUCT ) OF GRADE II TYPE III OF IS 12823/LATEST.* 52 Suplying of Laboratory Steel Furniture Sidebench with rack and table top of specification,Size of side benches/Island benches (LxWxH):1800 mm X 1800 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 53 Supplying of Laboratory Steel Furniture Island bench with table top Size of side benches/Island benches (LxWxH):900 mm X 1500 mm X 900 mm,Type of Frame for installation of bench:C type frame,C Type Fixed Under Bench Cabinet size:500 mm x 500 mm x 540 mm (having one door, one drawer and one adjustable/removable shelf) 54 Supplying ofPowder coated Round Classroom Stools Load of 50 Kg of stool of specification:Height Adjustment: Without Hydraulic,Frame and support made of CHROME PLATED MS TUBES,Chair Type:Non Revolving,Type of seating:Only seat,Pedestal base :Aluminium Die Cast 55 Suppling of Over Head Storage delite hi-tech of specification Material of Construction:ISI Marked, three layer Prelaminated particle Board conforming to Grade II Type III of IS 12823/2013 laminated with 0.6-0.8 mm thick lamination conforming to IS 2046/1995 and balancing lamination of 0.5 mm thick on the back side,Number of Shelves (Nos):2 Number of Doors (Nos) -2 ,Height in mm (±10 mm)-750,Depth in mm (±5 mm)-450 56 Suppling ofStainless Steel Name Plates, Monograms, Labels, As per BHEL ,Specifications :Stainless Steel Name Plates, Monograms, Labels, 57 Suppling of Aquaguard RO & UV both SS304 Drinking Water Coolers With Built In Water Purifiction System AquaguardR 58 Suppling ofStainless Steel External Branding Signage Boards, Size 22X6 Feet,Signage Printing-Single size vinyl print ,Material -Stainless steel ,Coating: Gloss or matte,Fabrication Specs-framing with one coat of red oxide & 2 coats of oil paint to avoid rusting 59 PROVIDING & SUPPLYING DIRECTOR DESKDIRECTOR TABLE STRUCTURE OF L SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2100MM(L)X 900MM(D)X 750MM(H) 50MM THICK TABLE TOP MADE OF PRELAMINATED PARTICLE BOARD WORK SURFACE WITH CLASSIC WENGE BROWN FINISH 2MM THICK PVC EDGE BANDING MADE OF SAME MATTE FINISH. SIDE PANNEL IS MADE OF 50MM THICK* PROVISION OF SIDE RUNNER OF SIZE IS 1200MM(L)X 400MM(D)X 760MM(H) ,(CCOMBINATION ONSTRUCTION BELOW TABLE TOP 1 KEY BOARD TRAY IN PVC WITH TELESCOPIC CHANNEL ON RIGHT SIDE IS MOVABLESIDE RUNNERHAVING 1 OPENABLE DOOR WITH 1 FIXED SHELVE, 1 OPEN BOX WITH 1 FIXED SHELVE UPPER SHELVE HEIGHT IS @ 320MM BELOW SHELVE HEIGHT IS @324@ + 3 DRAWERS (2 EQUAL DRAWERS + 1 FILLING DRAWER)PER DRAWER HEIGHT IS @ 184MM, FILLING DRAWER HEIGHT IS @ 303MM HAVE CENTRAL LOCKAND HANDLES WITH CASTORS .* MOBILE PEDESTAL OF SIZE400MM(L)X 530MM(D)X 671MM(H) ,PER DRAWER HEIGHT IS @ 186MM, FILLING DRAWER HEIGHT IS @ 195MM HAVING (2 EQUAL DRAWERS + 1 FILLING DRAWER) IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING.OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATEST , 60 PROVIDING & SUPPLYING* FIX CANTILEVER CHAIR * ALL OVER SIZE IS : 610MM(L)X 505MM(D)X990MM(H) , *THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR . IT WILL COMES IN MATTE BLACK FINISH FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS :CHROMEFINISH ARMS WITH PU PADDING .* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) . * SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORTbackrest support* ONLY SEAT SIZE IS 610MM(L)X 505MM(D)X485MM(H) & THE BACK SIZE IS 610MM(L)X 540MM(H) ,* BASE : CHROME FINISH TUBLAR FRAME OF CANTILEVER TYPE . 61 PROVIDING & SUPPLYING OFFICE DESK STRUCTURE OF RECTANGULAR SHAPE .PRIMARY WORK SURFACE OVER ALL SIZE IS 1200MM(L)X 600MM(D)X 750MM(H) 25MM THICK TABLE TOP MADE OF 25MM THICK PRELAMINATED PARTICLE BOARD WORK SURFACE WITH THE EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE WITH THE HOT MELT GLUE . MODESTY PANNEL MADE OF 18MM THICK, WIRE MANAGEMENT HOLE WITH PVC GROOMENT ON TABLE TOP.*CONSTRUCTION RIGHT SIDE OF TABLE TOP IS BASED ON A FIXED PEDESTAL3 DRAWERS & FROM LEFT SIDE OF TABLE TOP IS BASED ON 18MM THK ENGINEERED WOOD PVC EDGE BANDING PEDESTAL BACK,TOP,BOTTOM & DRAWERS ARE MADE OF 18MM THICK WITH 1 CPU TROLLY MADE IN BLACK METAL POWDER COATED.*FIXED PEDESTAL:L:410MM(L)X 580MM(D)X 750MM(H) ,IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. *THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823. 62 Suppling of Material & Subtype Solid Wood - Beech Wood Table Top Material Solid Wood,Leg Material Solid Wood Finish Glossy Colour & Colour Family Brown - Walnut Dimension (W)680mm X (D)530mm X (H)450mm Table Top Thickness 8mm,Size Compact, 63 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 838MM(L)X 305MM(D)X 1676MM(H) STEEL BOOKCASE HAVING 4 DOORS AND K. TYPE OF LOCK: THREE WAYBOLTING DEVICE CONTROLLED BY LOCK, THICKNESS OF MS SHEET USED FOR SHUTTER: 0.7 MM, THICKNESS OF MS SHEET USED FOR SHELF: 0.7 MM, THICKNESS OF MS SHEET USED FOR TOP,BOTTOM, BACK AND SIDES: 0.7 MM, MATERIAL OF HANDLE: CAST BRASS, THICKNESS OF TRANSPARENT GLASS IN SHUTTERS: 4.0 MM, THE COMPLETE STEEL STRUCTURE SHALL BE CONSTRUCTED BY WELDING AND PROVIDE FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 60-80 MICRONIN COLOR GREY-LIGHT GREY. 64 Suppling of 3 Seater Public Place Seating Chair of mildsteel with arm and backrest WITHOUT CUSHION DURIAN,THREE SEATERTYPE WAITING AREA CHAIR -NIXON/SS/3 MATERIAL : STAINLESS STEEL,SIZE 1820MM(L)X 690MM(D)X 790MM(H)COLOUR : SILVER/WEIGTH OF PRODUCT : 34 KG APPROX,* SUPPLYING AND PLACING IN POSITION OF A STAINLESS STEEL VISITOR BENCH OF SIZE IS 1820MM(L)X 690MM(D)X 790MM(H). THE COMPLETE STAINLESS STEEL BENCH HAS SEAT & BACK SINGLE SECTION. PER SEAT LENGTH IS @ 520 MM &SEATING HEIGHT IS @ 430 MM FROM GROUND . OWING TO THE SMOOTH FINISH, DURABILITY AND TENSILE STRENGTH BEAM STAINLESS STEEL MADE BY 1.6MM THICK.SEAT IS MADE BY 1.2MM THICK STAINLESS STEEL BORDER WITH CHROME PLATING FOR EVERY SEAT & BACK ; STAINLESS STEEL HANDLES CHROME PLATED & DIE PRESSED LEGS AT THE END OF CHAIRS.GROSS WEIGHT OF REGULAR 3-SEATER WILL BE 34 KG.THE STEEL GRADE 202 HIGH YIELD STRENGTH AS PER IS:513 & IS:304 GRADE. 65 PROVIDING & SUPPLYING ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE) 6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY. 66 PROVIDING & SUPPLYING * FIX CANTILEVER CHAIR PROVIDING & SUPPLYING* ALL OVER SIZE IS : 590MM(L)X 490MM(D)X940MM(H) ,*THE CHAIR MADE OF FULL LEATHERETTE IN BLACK COLOUR .IT WILL COMES IN MATTE FINSIH IN CONTEMPORARY STYLE .DETAILS :* ARMS : PADDED ARMREST.* USE OF PLY: SEAT & BACK PLYWOOD MADE OF 12 MM HOT PRESSED.* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT , * BACK : 35 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK . BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* ONLY SEAT SIZE IS 590MM(L)X 490MM(D)X450MM(H) SEAT HEIGHT IS @ 450MM .* BASE : 2 CHROME LEGS + BACK SIDE BOTTOM CHROME IN METAL . 67 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM). 68 SUPPLYING AND PLACING30 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated ParticleBoards Of Grade-II Type-II Of IS:12823/Latest (for 14 seater rate devided by 30X24} 69 SUPPLYING AND PLACING PREMIUM SUITESDIRECTOR TABLE STRUCTURE OF L-SHAPED DESK .PRIMARY WORK SURFACE OVER ALL SIZE IS 2400MM(L)X 2330MM(D)X 770MM(H) 45MM THICK TABLE TOP MADE OFSUPPLYING AND PLACING PRELAMINATED PARTICLE BOARD WORK SURFACE WITH RICH CHERRY FINISH SAME MATCHING EDGE BANDING MADE OF SAME RED CHERRY P.U POLISH.MODESTY IS DESIGNED WITH LEATHER PATCH.SIDE PANNEL IS MADE OF 36MM THICK .* PROVISION OF SIDE UNIT OF SIZE IS 1200MM(L)X 595MM(D)X 770MM(H) ,(COMBINATION CONSTRUCTION ON TABLE TOP WIRE MANAGEMENT 2 HOLE WITH SS GROOMENT & 1 HOLE WITH PVC GROOMENT ON TOP SIDE UNIT. BELOW TABLE TOP ONE KEYBOARD TRAY,IN SIDE UNIT BELOW THE TOP 1 KEY BOARD TRAY,1 OPEN BOX FILE ,1 DRAWER + 1 OPEANABLE DOOR SHELVE. * FIXED PEDESTAL OF SIZE450MM(L)X 400MM(D)X 690MM(H) , HAVING 3 EQUAL DRAWERS IN PROVIDED WITH CETNRAL LOCK FOR SECURITY AND HANDLES ARE PROVIDED FOR EASY OF OPENING. OVERALL CONSTRUCTION OF PEDESTAL IS 18 MM ALONG WITH FECIA OF DRAWERS. * ALL THE MDF BORAD ARE IS-14587-1998 WITH CONFIRM TO DIN 68861.ISO 9001- 2015 QUALITY CERTIFICATION CONFIRMING TO ASTM D 4499 STANDARDS FOR VISCOSITY AND THERMAL STABILITY . 70 SUPPLYING AND PLACING* HIGH BACK 360° DEGRE REVOLVINGCHAIR * ALL OVER SIZE IS : 673MM(L)X 508MM(D)X1270MM(H) , *THE CHAIR MADE OF FULL NATURAL LEATHER IN BROWN COLOUR . IT WILL COMES IN MATTE FINSIH EXTRA PADDED DESIGNED FOR MORE CONFIRMT AT WORKPLACE IN CONTEMPORARY STYLE . DETAILS :* ARMS : WOODEN ARMS WITH LETHER PADDING ARM REST ARE FITTED TO THE SEAT & BACK.* USE OF PLY: 12 MM THICK HOT PRESSED BWR PLYWOOD(IS GRADE - 303 FOR SEAT AND BACK) .* SEAT: 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN SEAT . * BACK : 40 ± 2 MM THICK POLYURETHANE FOAM WITH DENSITY 32 (±3) KG PER CU METER FOR BEST QUALITY CUSHIONING IN BACK .BACKREST SUPPORT FOAM DESIGN BASED ON SYMMETRICAL LUMBAR SUPPORT* MECHANISM : MULTI-LOCKING KNEE TILT MECHANISM .SEAT MAXIMUM HEIGHT IS 580MM & MINIMUM HEIGHT IS 500MM & BACK HEIGHT FROM FLOOR MAXIMUM HEIGHT IS 1270MM & MINIMUM HEIGHT IS 1219MM* GAS LIFT 80MM TELESCOPIC HAUDRAULIC * BASE : THE PRONG (BASE) IS MADE OF SOILD WOOD WITH POLISHEDAND FITTED WITH 5 NUMBERS. TWIN WHEEL CASTORS (CASTOR WHEEL DIA. 50MM) & 700MM PITCH CENTER DIA (740MM WITH CASTORS) . 71 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood Upholstery Material Leather,Seat Material Leather Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)1140mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 1 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 72 SUPPLYING AND PLACING Material & Subtype Leather - Semi Aniline Leather,Metal - Stainless Steel,Frame Material Solid Wood,Upholstery Material Leather,Seat Material Leather,Leg Material Metal,Finish Matte,Colour & Colour Family Beige - Mushroom,Dimension (W)2130mm X (D)1000mm X (H)940mm Mechanism Click Clack Mechanism,Seating Capacity 3 Seater Seating Height 430mm,Function Adjustable Headrest Size Grand. 73 SUPPLYING AND PLACING Rectangular CENTRE TABLE with Marble Top of 1219mmX711mm,(DAISY/CT (W)1300mm X (D)650mm X (H)450mm),Specifications:Number of storage under top No storage,Top material,Tempered glass,Frame material No frames,Dimension of Top (Length X Breadth, or Diameter) ±20mm,762mmX457mm,Height of centre table ±10mm,410,millimeter,Thickness of top material (+/-2 mm)- 8 millimeterThickness of frame material (+/- 1 mm)-10 millimeter 74 SUPPLYING AND PLACING 14 SEATER oval MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II 75 SUPPLYING AND PLACING 6 Seater Sofa Material & Subtype-Premium Leatherette,Frame Material Solid Wood,Upholstery Material Premium Leatherette,Filling Material Foam,Silicone Fiber,Seat Material Premium Leatherette-Leg Material Solid Wood,Finish Matte,Colour & Colour Family Brown -Coffee Brown Dimension (W)4865mm X (D)960mm X (H)820mm,Seating -Capacity 3 Seater,seating Height 475mm,Size Standard 76 SUPPLYING AND PLACING9 SEATER U -* PROVIDING & SUPPLYING U - SHAPE MODERN DESIGN CONFERENCE TABLE & IN BETWEEN U SHAPE TABLE TOP LENGTH IS @ 4650 MM, TABLETOP OFFERS YOU A GENEROUS WORKSPACE,DESK PRIMARY WORK SURFACE USE PREMIUM QUALITY MATERIALS OVER ALL SIZE IS 4650 MM(L)X 600MM(D)X 750MM(H) TABLE TOP MADE OF 36MM THICK WHICH GIVE MORE SURFACE AREA FOR WORK ,MACHINE MADE MODULAR FURNITURE MADE PRELAMINATED PARTICLE BOARD OF GRADE II TYPE III OF IS 12823/LATEST,* CONSTRUCTION PROVISION OF CONFERENCE TABLETOP SUPPORTED WITH 18MM THICK SIDE PANNELS IN BROWN-BLACK OAK COLOUR MADE BY PRELAMINATED PARTICLE BOARD AND BELOW THE TOP 18MM THICK PRELAM PARTICLE BOARD MODESTY PANEL.OUR WORK SURFACE FURNITURE IS FINISHED WITH EXPOSED EDGES SHALL BE FINISHED WITH 2MM THICK EDGE BINDING TAPE OF MATCHING COLOUR AND SHADE,FIXED WITH HOT MELT GLUE. * THREE LAYER PRELAMINATED PARTICLES BOARD(WOOD PRODUCT) OF GRADE II TYPE III OF IS 12823/LATESt. 77 * SUPPLYING AND PLACING THREE SEATER EXCLUSIVE PREMIUM LEATHERETTE MODERNIST CLASSIC DESIGN LOUNGE SEATING SOFA SIZE IS 1650MM(L) X750MM(D)X 710MM(H) WITH KILN-DRIED WOOD FRAMING MAKES IT WARP AND SCRATCH RESISTANT,COMFORTABLE SEAT DEPTH & HEIGHT DESIGNED KEEPING MODERN INDIAN LIFESTYLE IN MIND,WRAPPED IN BUTTERY-SOFT PREMIUM LEATHERETTE, THE PANELLED BACK AND CUSHIONED ARMRESTS ENCOURAGE LOUNGING,DESIGNED WITH MODERNITY & ELEGANCE, CHOOSE THE OPTION THAT SUITS YOUR HOME.* COMBINATION CONSTRUCTION STRUCTURE ARE MADE INMOISTURE CONTENT SHALL BE LESS THAN (10-12)%. THICKNESS OF PLYWOOD USED (MM) SHALL BE 12 MM GRADE IS 303 INDIAN STANDARD FOR COMMERCIAL (COMMON) AND MOISTURE PROOF PLYWOOD (TENTATIVE).UNDERSTRUCTURE FRAME SHALL BE CONSTRUCTED FROM 18 MM THICK KILN-DRIED GERMAN BEECH WOOD FRAMING IS HIGHLY DURABLE. THE COMPLETE STRUCTURE SHALL BE COVERED BY P.U.FOAM FIXED WITH ADHESIVE GLUE ,THE FRAME SHALL BE PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING 25 +/- 5 DENSITY IN SEAT IT SHALL BE STACK FOAM OF 40MM THIK,40MM THICK BACK FOAM HAVING 25 +/- 5 DENSITY FOAM USED ,THERE SHALL BE CUSHION ARM 40MM THICK PROVIDED PADDED WITH HIGH RESILIENCE POLYURETHANE FOAM HAVING DENSITY 25 +/- 5. THE COMPLETE STACK FOAM STRUCTURE SHALL BE COVERED WITH PREMIUM LEATHERETTE IN BROWN-CAMEL BROWN COLOUR, IT COMPLEMENTS THE MODISH SLEEK STEEL . ( SEAT : 545 MM(D) X 410MM(H) , ARMS HEIGHT @ 610 MM /BACK HEIGHT @ 290 MM) 78 SUPPLYING AND PLACING Wooden Acoustic Wall Cladding/Panelling- Providing and fixing in position wood wall paneling of width 128mm, thickness of 16mm and length 2440 mm made up of high density fiber board with minimum density of 800 Kg/m3 substrate with a laminated facing/wood veneer as per the approved shade/species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 2mm groove & 14mm pitch. The panels shall have fire resistance of Class 1, BS 476 part 7. The edges of the panels shall be tongued-and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece and backed with 50mm thick glass wool layer as directed by the Engineer-in-Charge. The panel shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install Gel stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall horizontalty using screws and plugs at spacing of 600mm centre-to-centre, Screw the aluminium channel (keel) vertically on channeled G.I stud 600mm 79 SUPPLYING AND PLACINGBlackout roller blind,Specifications-Mounting arrangement profile systems – clicked on hidden mounting clipsTypes of roller blind,Blackout roller blind-Shading solutionSingle roller blind – utilise one layer of fabric (called outer layer Operating mechanism-Side winders (that lock the manually adjustable blinds at different levels with the internal ratchet and tension adjusted by spring inside the tube) 80 Providing and Fixingof Drawers in Brown Finish ,Specification-Material : High QualityParticle board Dimensions (In Centimeters)-H 91 x W 90 x D 44 Dimensions (in Inches)-H 36 x W 35.5 x D 17.5 Primary Material-Engineered Wood as per Engineer incharge 81 Providing and FixingSTAGE - Providing & fixing raised stepped floor (Stage) Consisting ofMS Tabular frame work ofPipe Section (HOT ROLLED/COLD ROLLED) size 50mmx 50mmx2.0mm.tk. duly Painted with one coat of Red Oxide steel Primer, fabricated in module of 600 x 600 mm frame gid (as per Design or as instructed) with support of same section Legs /frame fixed on existing floor from base and raised at height minimum 150mm to max 200mm as required, from Existing floor. Vc providing and fixing 18mm thick heavy duty high density (1450 kg/cum) cement fiber Board fixed by SS. Screw on Horizontal & Vertical Surface on Existing Framework with one coated cement primer on Board and covering Board from top and sides by 2mm thick Vinyl flooring of approved make,colour and texture to be layed and fixed on sub floor smoothly finished and levelled by recommended adhesive cutting fixing and including covered raised portion of Board from all sides etc. complete,suitable for use up to the satisfaction of Engineer- in-charge.Design as approved by Engineer-In-charge. Base ofthe Vertical Legs of M.S. Frame (COLD ROLLED/HOT ROLLED) 82 Providing, fixing & installation MICROPHONE:-Flat frequency response across the vocal range for uncolored sound interchangeable cardioid, supercardioid, and omnidirec- tional cartridges that provide choices for applications Sleek, low-profile design for unobtrusive appearance Balanced transformerless output for increased immunity to noise over long cable runs-Compact Cinema Surround Speaker for Digital Applications:- Frequency range: 50 Hz to 20 kHz • High sensitivity: 91 dB SPL, IW @ 1m (3.3 ft) High power handling capability: 150 watts, continuous pink noise Internal Thermomaster• technology allows for unprecedented high frequency power in a compact, molded enclosure Convenient mounting design supports JBL QuickMountre, OmniMount• or APC multimount brackets Special cabinet shape incorporates 20• angled front baffle SMPTE/lS02969 Curve X high frequency de-emphasisMixer 8 input mono mixer XLR input switchable between mic and line level +/- 15dB gain trim control per input Input 1 is switchable to be pre/post master 24VDC or mains power operation Optional remote VCA/Tone generator/ Muting boards available • Whisper quiet operation 83 Supply, Installation, Testing and commissioning of microphone Delegate unit. 84 Supply, Installation, Testing and commissioning of microphone Chaiman unit, 85 Supply , Installation , testing and commissioning of Factory made 1.4HDMl Cable along with connector (15mtr length) 86 Supply , Installation , testing and commissioning of Factory made VGA along with Connectors.(15mtr length) 87 Supply , Installation , testing and commissioning of Factory made RCA along with Connectors.(15mtr length) 88 Supply , Installation , testing and commissioning 40W power Amplifier of following features:- Rated output wattage - 240W, amplifier output IOOV, 70V and 4-16 ohms transformer isolated speaker outputs, Supply input 0.775 v (OdB) unbalanced, 10k ohms, XLR and phone jack frequency 89 Supply , Installation , testing and commissioning10W wall mount speaker- Supplying, installation, testing and commissioning of 240W power amplifier with following features:- Rated output wattage- 240W, amplifier output 100V, 70V and 4-16 ohms transformer isolated speaker output, Supply input 0.775 v (0 db) unbalanced, 10k ohms, ZLR and phone jack frequency response 50 - 18000 Hz, +/- 1.5 dB, S/N ratio > 105 dB. 90 Supply , Installation , testing and commissioningCONFERENCE CONTROL UNIT, line Output 1 17.5V DC/3a Max.; -34dBV (20mV), line Output 2 17.5V DC/3a Max.; -34dBV (20mV), power Output 50w rMS at 2% THD, 90w Max. inputs 3xMic 0.65mV/4.7kQ Ixaux IOOmV/470kQ Frequency response 60-14,000Hz (± 3dB) 91 Supplying of Material & Subtype Engineered Wood Finish Matte,Colour & Colour Family Brown - Wenge Dimension (W)800mm X (D)384mm X (H)1970mm Size Standard,Style Contemporary,Assembly Type Knock Down 92 Supplying of Powder Coated Extruded Aluminium Sections Hybrid panel based system (combination of sliding & snap fit tiles) Modular Work Stations 93 Supplying of11 SEATER U - shape MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823 94 SUPPLYING AND PLACINGSLOTED ANGLE RACKOF SIZE 900MM(L)X 450MM(D)X 1800MM(H) SLOTTED ANGLE RACK (OPEN TYPE)6 SHELVES INCLUDING TOP & BOTTOM,ANGLES : 40MM X 40MM X 2MM(THICK).,SHELF : 36X15X1MM CRCA SHEET.IN COLOR GREY, 95 SUPPLYING AND PLACING : METAL STORAGE OF SIZE 900MM(L)X 450MM(D)X 1980MM(H) BODY MADE OUT IN 22 GAGUE(0.8MM) & DOOR 19 GAGUE(1 MM) CRCA SHEET. 4 ADJUSTABLE SHELVE IN 22 GAGUE(0.8MM) & PEDESTAL 18 GAGUE 1.2 MM CRCA SHEET. HAVING FOUR SHELVES MAKING FIVE COMPARTMENT, UNIFORMLY DISTRIBUTED LOAD CAPACITY OF EACH SHELF SHALL BE 60 KG MAXIMUM,FITTED WITH MS BODY LOCK & HANDLE. FINISHING WITH EPOXY POLYESTER POWDER COATED TO THE THICKNESS 50-60 MICRONS(+/-5 MICRON)IN COLOR GREY-LIGHT GREY. 96 Providing and fixing e Slimline Tower AC (2 Ton White),Availability of BIS/ISI Mark Certification for Split AC Floor type-Yes,Technology of air conditioner,Non Inverter AC-Nominal Marketing capacity as per BEE Star Rating Label (hint: 1 Ton = 3000 Kcal/Hr, Tolerance +/- 10%) (in Ton)-3 BEE Star rating of the product (Central Ministries/Departments while procuring shall ensure that the items carry 5 star (under normal conditions where annual usages is expected to be more than 1000 hrs),3 Star (where usage is Limited)or higher Star R NA- Star rating for the capacity of >10,465 Watts (>9,000 kcal/hour) 97 Providing & Fixing 2.0 mm thick homogenous single layered vinyl flooring. The flooring shall be laid in manner to provide comfortable and jerk free surfaces including material, adhesive, scaffloding and lead and lift at all floor level etc. complete as per direction and approval of Engineer-in-charge. 98 Providing & Fixing Wiring for Primary Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insuate copperconductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point With 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Switch with Front plate and metal Box with all Accessroies for users. 99 Providing & Fixing Wiring for Secondry Raw Power point 2 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 2 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with all Accessories. 100 Providing & Fixing Wiring for Primary Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 101 Providing & Fixing Wiring for Secondry Raw Power point 1 sets of 6 Amp Switch-Socket Outlet with 2.5 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq.mm FR PVC insulated copper conductor Wire. Including Providing and fixing 1 nos 6A Socket controlled by 1 nos 6A Switch with Front plate and metal Box with allAccessories. 102 Wiring for Primary Power point 6/16 Amp Switch-Socket Outlet with 4 sq.mm FR PVC insulated copper conductor wire in surface / recessed 25mm medium class PVC conduit, earthing the third point with 2.5 sq-mm FR PVC insulated copper conductor Wire. Providing and fixing 1 nos 6/16A Socket controlled by 1 nos 16A switch with front plate and metal box with allAccessories. 103 Providing & Fixing Standing Bathtubs Specifications:Size:1690x800x445/565mm Free Standing Bath Tub with Over Flow & Drain 104 Providing & Fixing Corazzin Garden Patio Seating Chair and Table Set Outdoor Balcony Garden Coffee Table Set Furniture with 1 Table and 4 Chairs Set (Black) 105 Providing & Fixing Reliable Drapes Cotton Plain Door Curtains Reliable Drapes,Cotton GSM Quality-220,Lining included-No, Pack of-1,Length (Ft)-8.5-9,Width (Ft)-3-3.5 106 Providing MattressDimension 1981 mm X 1829 mm,Thickness of Core Layer (Height of Spring) 200 mm,Thickness of Felt (±1 mm) for Bonnell Spring 12 mm,Thickness of Top Layer (±2 mm)-50 mm Thickness of Bottom Layer (±2 mm)50 mm,Type of Spring in Core Layer Bonnell Spring (with cotton felt),Material of Top Layer Visco Elastic PU Foam (Memory Foam) 107 ProvidingCotton Pillow 33 cm x 56 cm (COTTON PILLOW)of Specification-BIS Marking ( For Body Casing fabric )-No Logo Marking-No,type of Logo,Stitched ( Patch Logo ),Agree to provide 108 Providing240 centimeter x C1112M 135 centimeter (L x W) Printed Bed Sheets(BED SHEET ):Technical Specification of the Product-Sheeting, Tickings and Bedsheets (V2) as per IS 175 BIS Certifcation-No,VarietyVariety - 2,Process of colouring Dyed,Matching Pillow cover 109 Providing 25 liter 3 Star Water Heater,25 Ltr 5 Star Water HeaterCapacity litres (Litres),BEE Star Rating (Central Ministries/ Departments while procuring shall ensure that the items carry 5 star or higher Star Rating of BEE)-3,Availability of Type Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification-No,Material of Inner Container Vitreous enamelled inner tank conforming to IS-13273 110 Providing Wall Mount Mesh Filter T-Shapped Kitchen-Chimney Material of Blower Body-Aluminium,Material of Blower Blade Aluminium,Material of Exhaust pipe-pvc,Filter Material,Stainless Steel,ShapeT-Shapped,Filter Type,Mesh Filter,Control Panel Type Soft Touch,Mount Type,Wall Mount 111 Providing Potable Water Purification System With Inbuilt Water Cooler. RO UV Aquaguard(Hot & Cold uv+ ro) Specifications-Flow rate (Litres/hr.)-12,Cold water storage capacity (Litres)-11 liter,Cooling capacity (litres/hr.)-4,Hot water storage capacity (Litres)-1.5 liter,Heating capacity (litres/hr.)-1.5,Cooling power consumption (Watts)-230,Heating power consumption (Watts)-550. 112 Providing300 L 3 Star Frost Free Double Door Refrigerator, of specification Cooling type:Frost free,Exterior body built:steel,Shelf material -Toughened glass,Voltage Range-160-300V,frequency-50 Hz 113 Providing900 mm wide 2000 mm high Metal Shelving Racks,Specifications :Type-OPEN TYPE Number of Shelves/Compartments (Top / Ceiling Shelf - not to be counted)-4,Shelves Material-0.8 mm Thick MS Sheet Conforming to Commercial Quality CR-1, Grade 340 of IS 513,Depth in mm (±5 mm)-400,Width in mm (±5 mm)-900,Height in mm (±5 mm) 2000 114 Providing and fixing Drawers of Specification of Dimension (in cm)-H91 X W90 X D44in Brown Finish,primary material-Engineered wood,Weight 49.45kg 115 Providing and fixingDressing Table With cupboard and open shelves-Design of Dressing table With drawers,cupboard and open shelvesBase of dressing table Rectangular wooden frame Number of side mirror-1 number, Material specification-Prelaminated particle board of grade II type III of IS 12823/Latest.both side laminated. outer side laminated with shade matching with top shade and fascia shade and having balancing laminate of 0.5mm thick on other side Material thickness of complete body, Fascia and drawer/cupboard-19 millimeter,Material thickness for back, partition and drawer /cupboard bottom ± 2mm,19 millimeter 116 Providing and fixing Material & Subtype Solid Wood - Rubber Wood Table Top Material Solid Wood-Frame Material Solid Wood,Finish Glossy,Colour & Colour Family Brown - Walnut Dimension Of Table (W) 600mm X (D) 600 X (H) 610mm Dimension Of Chair (W)640mm X (D)530mm X (H)560mm Size Standard 117 Providing and fixing Wooden Double Bed Storage Box Opening From Material of Mattresses Panel-Other wood, Material of Bottom Panel of Storage Box-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Front, Back and side Panels Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Headrest Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest Material of Legrest-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest,Type of Bed-Wooden Double Bed Material of Bed Frame-Three layer prelaminated particles board (Wood product) of grade II type II of IS 12823/Latest 118 Providing and fixing 1 Seater Sofa With Leatherite Cover Sofa Set is Foldable to use as bed-No Backrest Cushion Material-Foam,density of Cushion of Backrest Material (Kg/Cubic M)-40 Covering Material for Seat and Backrest Fabric Frame Structure Material and size (±1 mm) Any other wood of minimum 25 mm thickness Seat Cushion MaterialFoam 119 Providing and fixing 8 SEATER Rectangular MEETING TABLE with table top of Three Layer Prelaminated Particle Boards Of Grade-II Type-II Of IS:12823/(Elanor Marble 8 Seater Dining Set) 120 Providing and fixing MODULAR TABLE L X D & H 2000 millimeter X 450 millimeter 700 millimeter (Alice TV Unit marble),Sprcification-Mode of Supply of modular table Knocked Down to be assembled at consignee site by the Seller Storage Provided one side,Number of storage unit-triple storage,Table Top material and thickness ±3mm-25mm thickness three layer pre-laminated Particle boards (Wood Product) of grade II Type II of IS 12823 Latest Gable end and modesty panel material and thickness-18 mm thickness three layers pre-laminated Particle boards (Wood Product) of grade II Type III of IS 12823 Latest 121 Supplying of Library Management Department. and NDL Softwares,Server Machines, Air-Condition Systems,Xerox Machines,Lamination Machines, CONNECTION)Binding Machines,Furniture/Furnishing. Computers, Printers,Computer System(with Internet Connection) 122 Supplying of Printer of Specification A Printing Technology Laser-Cartridge Technology,Composite Cartridge,Type of Printing Mono,Paper Size-A4 Print Speed per minutes per Department Incharge 123 Supplying of XEROX Machine(standard company) Type of MachineMultifunction Machine,Print Technology-Laser Type of Printing-Mono,Cartridge Technology Separate Drum and Toner (Dual Component) Platen/Flatbed Size-A3/A4,Paper Size (Original/Image)A3/A3 RAM size (MB)-4096as per Department incharge 124 Supplying of Determination of wavelength of He-Ne Laser light using Grating(Specification- Output Power: up to 15mW, CW - Wavelength: 632.8nm,* Mode Structure: TEM00 (>95%)* Beam size: <= 1mm* Beam Divergence: <= 1.5 mrad* Polarisation: Unpolarised, Vertical Polarisation. complete set up as per Department incharge 125 Supplying of Brewsters Law using spectrometer(Brewsters angle apparatus differ goniometer digital research bench polarizer analyser with rail type bench abron). complete set up as per Department incharge 126 Supplying of Determination of wavelength of Sodium light using Michelson interferometer(Power-3 kW,Usage-Physics Lab,Material-Mild Steel,Power Source,Electric Voltage 240 V). complete set upas per Department incharge 127 Supplying of Determination of wavelength of Sodium light using FabryPerot interferometer complete set up of Specification Flatness of Reflective Mirrors-λ/20 Diameter of Reflective Mirrors-30 mm Reflectance of Mirrors-95% Effective Travel of Preset Micrometer~ 3 mm Min Division Value of Preset Micrometer-0.01 mm Travel of Fine Adjustment of Movable Mirror-1.25 mm Resolution of Fine Adjustment-0.0005 mm Low-Pressure Sodium Lamp-20 W as per Department incharge 128 Supplying of Resolving Power of Telescope complete set up (specification Color-BlackMaterial-Plastic as per Department incharge) 129 Supplying of Resolving Power of Prism(Resolving power of telescope assists the user to know the basic principle of telescope. Fabricated using excellent quality metals, glass and plastic material, it is widely used instrument in scientific lab of colleges and research centers. It is known for accurate calculation and longer service life) complete set up as per Department incharge 130 Supplying of Production and analysis of Polarised light using half and quarter wave plate(Usage/Application Laboratory Voltage-230 V,Color-Black,Material-SS). Complete set up as per Department incharge 131 Supplying ofLogarithmic Amplifier(Built in power supply : +15V & -15V DC,Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet,Weight : 2KGS APPX) complete set up as per Department incharge as per Department incharge 132 Supplying of Zener diode characteristics & voltage stabilizer. Complete-Specification:(Voltage-240 V Frequency-60 Hz,Display Type -Analog)in all respect as per Department incharge 133 Supplying of FET characteristics complete up(Technical specifications-Inbuilt variable, overload & short circuit protected DC regulated power supplies of 0- 5 volt & 0- 15 volt.Voltmeter & ammeter are mounted on the front panel.One FET.Highly insulated front panel .Trainer helps to demonstrate the working principle of FET.Set of required number of patch cords.Multi - colored sockets are used.Housed in an elegant powder coated metal cabinet.Strongly supported by a comprehensive instruction manual complete with theory and operating details.LED indication for supply “ON” to work on 220V AC Mains.) as per Department incharge 134 Supplying of MOSFET characteristics complete set up(Specificaion:Power-AC Mains,Usage/Application-Laboratory Type-Analog,Material-plastic,Power Supply-ac mains, as per Department incharge 135 Supplying of UJT characteristics complete set up(Specification-Usage/Application-laboratory,Type-Analog,Display Type-Analog meters,Power Supply-ac mains)as per Department incharge 136 Supplying of Transistor biasing (CE mode)(Specificaion-Operating Power Supply-220VAC On Board Power Supply 0-1VDC & 0-10VDC Experiment Input & Output Char In CB & CE Mode OF PNP Tr.Meter Type Analog / Digital)set up as per Department incharge 137 Supplying of Characteristics of SCR(SpecificationUsage/Application-laboratory Type-Analog Automation Grade-Manual ,Power Supply-ac mainscomplete set up as per Department incharge 138 Supplying of Basic Logicgates and Universal gates. Operating Supply Voltage 230V,Logic Family-DIGITAL,Number of Inputs per Gate-2,Usage Laboratory,Material-ELECTRONIC Complete set up in all respect as per Department incharge 139 Supplying of Op-amp Integrator &Differentiator. Complete set up in all respect :Product Specification:Type-Analog Material-Metal,Automation Grade=-Manual,Color-black with multicolour PVC front panel,Power Supply-230,Capacity--5,connector Type-patch cord sas per Department incharge 140 Supplying of Half Adder, Full Adder and 4-bit binary Adder. Complete set up in all respect (Product Specification:Type-Digital,Display Type-Digital Interface--NO Material-ABS,Display-Digital,Pulse Generator-50Hz Variable Dc Output-no)as per Department incharge 141 Supplying of G. M. Counter for 6 digits GM counter with built in power supply complete set up(G.M.COUNTER: COMPLETE WITH INBUILT POWER SUPPLY EHT 250-1200v Workable on 220v. 50Hz., Power consumption 8W approx. STOP, START, RESET switches. Counts Capacity : 6 DIGIT COUNTING SYSTEM, Preset time : 3 DIGIT PROGRAMABLE TIMER WITH DIGITAL DISPLAY. 3 ½ Inbuilt Digital Volt Meter for GM TUBE Voltage. G.M.TUBE: END WINDOW G.M.TUBE MOUNTED IN ACRYLIC STAND. WITH ‘LEAD’ AND ‘ALUMINIMUM’ ABSORBENTS, Radioactive Source: ONE RADIOACTIVE SOURCE BETA or GAMMA (in Lead Container and wooden Box) SOURCE, . Dimensions : 460X370X230mm.(Complete instrument is HOUSED in corrugate box with Export Packaging) Wight : Total weight of the Instrument is 5.5kg.) as per Department incharge 142 Supplying of Measurement of Dielectric constants of solid and liquid samples complete set up(It Consists of following partsRF Generator (9-10MHz Approx) Micro Ammeter (Range 0-50mA) Potentiometer for Sensitvity Selection Fixed Capacity (Metal) Variable Gang Capacitor Socket for test Capacitor & Variable Capacitor brought out at front panel One Solid bakelite plate to be insert in gap of test capacitors)as per Department incharge 143 Supplying of Study of Dielectric constants and Curie temperature of ferroelectric ceramics Complete in all respect(Specifications Temperature Range : Ambient to 200°C,Display : 31/2 digit, 7 segment LED with autopolarity & decimal indicationResolution : 0.1°C,Accuracy : ±0.5°C (typical),Stability : ±0.1°C Power : 150W,(ii) Digital Capacitance MeterThis a compact direct reading Instrument for the measurement of capacitance of the sample. Specifications,Range : 50-6000 pf,Resolution : 1pf Display : 3½ digit, 7 segment LED, Typical results obtained with the above set-up are as shown in the graph) as per Department incharge 144 Supplying of Determining Optical constants of a metal by reflection of light Complete in all respect (Specification-Power-AC Mains,Usage/Application-Laboratory,Type-Digital Material-Metal,Automation Grade Manual,Color-White Power Supply-AC Mains,Display Type-Digital) as per Department incharge 145 Supplying of Lattice dynamics kit with frequency meter (Technical Specifications: Audio Oscillator 100 khz,Built in Power Supply and Output Stage to match the Impedance of Simulated Lattice,Lattice DynamicKit consists of Transmission line, which Simulates One-Dimensional Mono-AtomicandDi-atomicLattices,. LCD Based Frequency Counter is Provided on panel to Measure Frequencycomplete set up as per Department incharge 146 Supplying of BCD to seven segments complete set up(Specification:Built in power supply : +5V DC Mains : 230V AC Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX) as per Department incharge 147 Supplying of Monostable Multivibrator using Oscilloscope (CRO) complete set up (Specification:Usage/Application Laboratory Packaging Type-Corrugated Box,Connector-2mm sockets Frequency Range -50Hz) as per Department incharge 148 Supplying of Bistable multivibrator using Oscilloscope(CRO))Technical Specification:(Built in power supply : +12V & -12V DC Mains : 230V AC,Dimension : 27CMS X 17CMS [metal cabinet] Weight : 2KGS APPX)complete set up as per Department incharge 149 Supplying of Pulse code modulation and demodulation complete setup (Product Specification,Type Laboratory Trainer Kit Usage/Application-Laboratory,Accuracy-+/- 10%,Frequency-50 Hz Input Voltage-220V,Packaging Type-Corrugated Box,Power Source-ElectricShape-Rectangular,Material-ABS or Metal Cabinet)as per Department incharge 150 Supplying of Addition, Subtraction, Multiplication using 8086 microprocessor(Product Specification,Usage/Application-LaboratoryType-Fully Automatic,Automation Grade-Semi-AutomaticClock Frequency-Yes,Color-Green,Display-Digital Packaging Type-Corrugated Box, Power-200-400 Weight 2 Kg) as per Department incharge 151 Supplying of Thevenin theorem, (THEVENIN’S AND NORTON’S THEOREM APPARATUS,Technical specifications Inbuilt fixed DC regulated power supply of 12 volt. Voltmeter & ammeter are mounted on the front panel. Resistive network is used in the circuit. Circuit diagram is printed on highly insulated front panel . Trainer helps to demonstrate the working principle & verification of Thevenin’s & Norton’s Theorem based on resistive circuit. Student can calculate & measure the value of current & voltage for different load circuits. Calculation of power consumed by the circuit. Facility for connecting external Power Supply. Set of required number of patch cords. Multi - colored test points are provided in the circuit to observe voltages at different points. Housed in an elegant powder coated metal cabinet. Strongly supported by a comprehensive instruction manual complete with theory and operating details. LED indication for supply “ON” to work on 220V AC Mains. Circuit protection through glass fuse)Complete set up as per Department incharge as per Department incharge 152 Supplying of Active filter set up(Product Specification Operating Temperature-0-50,Frequency (Hz) 50,Condition-New Temperature (deg. Celsius)-50,Usage/Application Industrial, Educational, Residential, Commercial) as per Department incharge 153 Supplying of A to D counter type complete set up (Product Description-M-32 AD M-16 AD,Input AD: 1/4 TRS jack and 25 pin D-sub, servo balanced, completely symmetrical audio path, Output AD: 4 x ADAT optical, 1 x MADI optical/coaxial,Dynamic Range AD: 113 dB RMS unweighted, 116 dBA,THD AD: < -110 dB (< 0.00032 %),THD+N AD: < -104 dB (< 0.00063 %) Crosstalk AD: > 130 dB,Input level for 0 dBFS: +24 dBu, +19 dBu, +13 dBu,Frequency response AD, -0.1 dB: 10 Hz - 23.2 kHz (sf 48 kHz),Frequency response AD, -0.5 dB: < 5 Hz - 45 kHz (sf 96 kHz) Frequency response AD, -1 dB: < 5 Hz - 80 kHz (sf 192 kHz) Sample rates: 44.1, 48, 88.2, 96, 176.4, 192 kHz, variable (Sync/WC),Jitter: Typical < 1 ns for internal, Word Clock, ADAT and MADI input Jitter sensitivity: all PLLs operate error-free even at 100 ns,Jitter suppression: > 30 dB (2.4 kHz),Power supply: Internal switching mode PS, 100V - 240V AC, 60 Watt Dimensions: (WxHxD) 483 x 88 x 200 mm)as per Department incharge 154 Supplying of Determination of Plancks constant(1. 1 0-2V D.C. at 20mA Variable Power Supply. 1.2 Digital Panel meter 3½ digits range 2mA. 1.3 Digital Panel meter 3½ digits range 2 volt 02 Lamp House: 100W Bulb with stand 03 Vacuum Type Photo Cell : Mounted in a Iron box. 04 Three different colour optical filters 05 Adequate no. of patch cords stackable 4mm spring loaded plug length 50cm. 06 Strongly supported by detailed Operating Instructions, giving details of Object, Theory, Design procedures, Report Suggestions and Book References.) as per Department incharge 155 Supplying of Determination of Energy Band Gap using Four Probe method(Product Specification:Type-Energy Band Gap Usage/Application-Laboratory,Connector-4mm Banana Socket Frequency-50Hz) as per Department incharge 156 Supplying of Determination of Hall coefficient and Hall angle in Hall-effect(Product Specification,Display Type-0-20V DC, 0-5 A, digit LED, Primary safety socket,4mm Electro Magnet Coils 500 T, Voltage resolution -0.1V,Current Resolution 0.1 A) as per Department incharge 157 Supplying of Determination of magnetic susceptibility using Guoys method(Usage/Application Physics Laboratory Type Of Instruments-Magnetic Susceptibility Gouys Balance Method Experiment Setup,Power-230V , 50Hz, +-10% Display Type-LED Type) as per Department incharge 158 Supplying of Study of absorption pattern of a given sample using FTIR spectrometer(Product Specification,Detector-High performance pyroelectric infrared detector,Weight-15 kg Software-1,Voltage-100-240V AC,Electronic System-24bit A/D converter at 500KHz, USB 2.0,Wavenumber Range-7800~350 cm-1Power-100-240V AC,50/60Hz,Signal Noise Ratio-30000:1 (resolution@4cm-1 , sample and background scan for 1 min@2100cm-1 ),Light source-Long life, steady state infrared emitter Beam splitter-coated KBr,Resolution-1 cm-1,Dimension-430mm x 360 x200) as per Department incharge 159 Supplying of LCD Projector and smart board (Product Specification,Projection Distance-<1 m Resolution-WXGA,Lamp Life-5000/9000/10000 HOURS Screen Size-100,Display Type-LCD,Dimensions-400X367X149MM Connectivity Type-Dual HDMI, HDMI,Brightness-2000-4000 Lumens Color-White) as per Department incharge 160 Supplying of Desktop(ntel Core I3/ 10th Gen/ 4GB RAM/ 1TB HDD/ DOS/ NO DVD/ 19.5 Inch Monitor/ 1 Year Warranty) as per Department incharge 161 Supplying of Printer(Product Specification,Printer Type-Ink Tank Color Output-Color,Print Speed-22 ppm,Paper Size-A4,Dimension-403 x 369 x 150 mm,Weight -6,Warranty-One Year or 50,000 pages which ever is earlier) as per Department incharge 162 Supplying of Printer (Product Specification Printer Type-Inkjet Color Output-Color | B&W,Print Speed-10,Paper Size-A4,Connectivity-USB,Dimension-377 x348 x179,Weight-3.9 Print Volume-any)as per Department incharge 163 Supplying of XEROX Machine (Product Specification,Functions-Photocopy,Supported Paper Size-A3,Supported OS-Windows 10 Color Output-Black & White,Number Of Trays-1,Item Color-Black & WhitePrint Speed-22 PPM,Weight-40 kg,Print Technology-Laser Input Tray Capacity-350 sheets,Warm-Up Time-5.6 Sec,Duty Cycle-80000 / Month,Resolution-600 x 600 dpi Connectivity-Ethernet & USB,Duplexing-Yes)as per Department incharge 164 Supplying of computer system with internet connection,PC Specifications to be followed :Processor Intel Core i5(10th Gereneration or newer ),RAM-8 GB or Higher HDD:512 GB,SSD,Monitor 24 LCD Monitor .OS:Windows 10 Professional ,Anti virus:User Licence for one year as per Department incharge 165 Supplying of Laptop (with Internet connection),Processor intel Core i5(11th Generation or newer),RAM 8 GB or higher HDD:512 GB,SSD Monitor 14 screen ,OS Windows 10 Professional ,Antivirus :User Licence for one year 166 Supplying of LCD Projector (Specification-Brightness:2000-4000 Lumens,Resolution-FULL HD 1080P,Connectivity Type-Dual HDMI, HDMI Display Type-DLP,Power Supply-100-240V Portable-Yes) as per Department incharge 167 Supplying of Smart Board (Frame Material-Aluminium Usage/Application-School, Education, etc,Effective Touch Area-72 x 48 inch Material-Ceramic Input Method-USB Power Consumption-150 - 220 W,Shape-Rectangular) as per Department incharge 168 Supplying of MS Suite Software(Specification-Microsoft Office Software,Operating System:For Windows,Brand:Microsoft )as per Department incharge 169 Supplying of Adobe Photoshop Software(Specification -Graphic Design and Photo editing,Licence-1 yea) as per Department incharge 170 Supplying of windows10 OS Software(Specification-License Duration-Life Time,Architecture-32/64 Bits,Operating System For WindowsAlso Provides,Windows Operating System,Provide Installation Service-Yes Support 24/7 (Live Rep)) as per Department incharge 171 Supplying of Laptop of 11th Generation intel core i3,1115G4 processor (6 MB Cache up to 4.1GHZ)windows 10 Home Single language English,intel UHD Graphics with shared graphics memory 8GB ,8 GBX1,DDR4,3200 MHZ,512 MB,2 PCLeNVMe Solid state drive pebble (Top colour is pebble colour,Base and palmrest are black colour as per department incharge 172 Supplying of Desktop of 10th Generation intel core i5-10500T (6 CORE,12MB Cache 2.3GHZ to 3.8GHz,35W ),Windows 10 Pro (64 Bit )English,intel integrated graphics),8GB ,1X8 GB,DDR4 non-EC0C Memory,2.5 inch TB 7200 RPM ,SATA Hatd disk drive 5480AJO 23.8 FHD 1920X10080 ips non touch,Antiglare camera,integrated graphics,Bronze 1505w PSU as per department incharge 173 Supplying of Printer (Specification:Item Weight-12 Kg,Package Dimensions-60 x 56.5 x 38 cm,Connectivity Type-Wi-Fi Operating System-Windows)as per department incharge 174 Supplying of Fumehood(Specification:Type-exhaust,LED-Tube fitting,Power-230 volt,Working Top-Granite ,MOC-GI with PU coated Storage includedas per department incharge 175 Supplying of electronic balance(Specification -Usage/Application-Laboratory,Accuracy-0.01%,Calibration-Fully Automatic,Type Of Weighing Scale-Digital,Voltage-110-220 V Mounting Type Desktop) as per department incharge 176 Supplying of Magnetic stirrer Magnetic stirrer Hot plate (Specification-Weight-2.3 kg,Timer -999 minutes,Temp. Accuracy-+-1 Deg.C(<100 Deg.C)+-3 Deg.C(<300 Deg.C),Dimensions LxWxH (mm)-230 x 180 x 120,Max.Temp. (Plate Surface) 300 Deg.C,Power supply-AC 220V / 50 Hz,Top Plate Size 135 x 135 mm,Display-LCD,Max. Volume (ml) 2000 ml,Speed (RPM)-1250 RPM Plate Material Steel per department incharge 177 Supplying of HOT Air oven of made inner material-stainless steel,Outer material -mild steel ,Surface treatement -Powered coated ,Sizes-Different sizes,Gravity conviction type-Double wall.Mechnical conviction -Triple wall as per department incharge 178 Supplying of colourimetry , Ery colour colorimeter industrial and research purpose stability( Product Specification:Material-Aluminium Alloy,Automation Type Automatic,Brand -DD-LAB ,Dimension-210 x 160 x 80 mm,Display Type-Dual Digital DisplayLight Source-Highly Accurate Laser Source,Stability- + 0.02 O.D. Per Hour Volume 1 ml. minimum,Filters layer-Built in 9 Digital filters 30,000 hours Life,Weight-1.5 Kg,Battery Backup-6 V Ni CD Re-chargeable Battery,Detector Silicon Photo-diode,Display Model Absorbance & Wavelength,Filter Wavelength 680 NM Country of Origin Made in India) as per department incharge 179 Supplying UV-Vis Spectrophotometer Fully touch screen portable UV Spectrophotometer shimadzu model name:UV 1900,Brand :shimadzu,Display =fully touch screen,Type-portable,size 450x501x244 as per department incharge 180 Supplying of potentiometer ,Range-0 to 1999.9mv,Resolution-1 mv,Repeatability -1mV,Accuracy +1 mv+ digit,Input impedency-10ohms,operating temperature 10 to 50 degree Celsius,Display 1/2 digit 0.5 seven segment LED Display indication,Power-230V+10,50hZ,Dimensions 76x275x170 mm,weihjt 2 kh as per department incharge 181 Supplying of Conductivity meter,LT 26 Deluxe conductivity meter,Product details:Model no-LT-26,Brand -Labtronics,Usage-Laborataty,Display type 3.5 Digit LEDas per department incharge 182 Supplying of Online COD/BOD Detector analyzer warer quality monitoring probe,Measure range-0-200/0-1000mg/l,Resolution -1 mg/l ,Accuracy +5%F.s ,Under pressure-1 bar,Power supply -12-24V DC ,Temperature range 0-45 degree ,Production leve;-IP68 as per department incharge 183 Supplying of melting point appratus,Temperature renge -2 degree above ,Readability 1 degree ,Display -3 Digit LED,Heating rate control-Electronic,Temperatre sensor PT-100as per department incharge 184 Supplying of Ph meter Labrtonics,Range:0-14pH,Resolution:0.01pH,Accuracy:0.01pH(Relative),Temp comp:Automatic wvith temp probe,Buffer:Manuals with keys as per department incharge 185 Supplying of Spectrum 3 FT-IR Spectrometer,Model no.-LI280127,Wave length -11000-30 cm-1 as per department incharge 186 Supplying of Stopwatch NIVIA 600 plastic(Product Specification:Color-Black,Usage/Application-Sports,Time Display 12/24 hour display for user option,Material-Plastic,Dial Shape-OvalMaximum Counting-23 hours 59 minutes 59 secondsas per department incharge 187 Supplying of Digital Bomb Calometer(Specification-Auto Off Automatic,Frequency-50 Hz,Voltage-230-280 V,Operating Time Per Test 10 minutes,Power Source Electric(Automatic) as per department incharge 188 Supplying of Microprocessor viscometer ,Product details: Measuring range-101x105mpa,,Spindles-4 Spildles,Rotor speed(rpm)-6/12/30/60 rotor speed rpm as per department incharge 189 Supplying of Flame photometer,Product details:Application-Laboratory use,industialuse,,weight 705kg ,Curve fit accuracy,Resolution-0.1ppm/meq as per department incharge 190 Supplying ofwater purification system,Resolution-18.2 M ohm cm at 25 degree C,Weight-19.5kg,Frequency-50-60Hz as per department incharge 191 Supplying of Refrigerator of 7.5kg fully Automatic Top Load washing machine (Hard water wash,Grey,5 star,10 years warranty as per department incharge 192 Supplying of water bath ,unstirred water bath s ,Digital info Water bathdigital,18L amb+5 tp 99 degree C includes clear lid and base trayas per department incharge 193 Supplying ofmini rotary shakers 50to 400RPM,features-220/230 V ac,Power supply-50-60Hzas per department incharge 194 Supplying of Magnetic stirrer- capacity 5 litre Spinit Digital Magnetic Stirrer Features-Type of Product-Magnetic stirreras per department incharge 195 Supplying of Digital ultrasonic cleaners (Specification: tank capacity 4 L, ultrasonic power 100W, Heating, Power-100W, time setting 1-99 min, heating temp up to 80 degree, in and out both in ss, with digital timer auto stop of sonication. 230V AC +-10% 50HZ. Tank size 300x150x100mm, overall size 330x180x240mm.supplied with basket and Lid.) as per department incharge 196 Supplying of Calomel electrode (Product Specification:Packaging Type-Box.,Length-120 mmUsage-Electrochemical Study(Laboratory))as per department incharge 197 Supplying of Pt-wire counter electrode (Product Specification Electrode Diameter-0.5 mm,Power Source-10A) as per department incharge 198 Supplying of UV-LAMP Cabinet(Product SpecificationSize/Dimension-15 X 12 X 10 (H) Light Source-3 NOS , SHORT WAVE -254nm-1no, LONG WAVE-365nm, VISIBLE LIGHT,Material-MILD STEEL,Voltage 230 V AC) as per department incharge 199 Supplying of Magnet (Magnet Grade-N48 Shape-Cup & Pot,Material Neodymium,Dimensional Tolerance+-0.05 mm,Plating / Coating-Ni-Cu-Ni Colour-red,Surface Gauss 3000 Gauss,Maximum Working Temperature (Deg. C)-230 Deg. C as per department incharge 200 Supplying of Micro Centrifuge tube(Specification: Usage/ApplicationLaboratory Analyzers,Material,Polypropylene Color-White,Pack Contains--20 Packet / carton & 500 pcs / packet,Shape-Conical,Length-4.1 cm,Inlet Diameter-1.3 cm Capacity2 ml)as per department incharge 201 Supplying of Micropiprtte(10-100uL),(Product Specification Capacity-10 ml,Volume Increment -0.1 microlitre Material-Glass,Autoclavable-Yes)as per department incharge 202 Supplying of Micropiprtte(10-1000uL),( Product Specification Material-Plastic,Capacity-Up to 1000ul,Color-Transparent Usage/application-Chemical Laboratory) as per department incharge 203 Supplying of printer-Black and white print ,scan,copy all in one printer Product Specification Print Speed-Up to 18ppm / 19ppmLaser Printer,Color Output-Black & White,Print Technology LaserjetUsage/Application-Printing,Supported Paper Size-A4 Compatible Operating Systems1,Windows 8,Windows 7,Windows Vista,Windows XP,Windows 2000,Mac OS X 10.4 - 10.8,Linux*3 Print Resolution-Up to 600 x 600DPI,1 200 (Equivalent) x 600DPI,Print Language-UFR II LT Dimension-372 x 371 x 254mm (With the Cassette Opened)Weight(W/O CRG)-7.6kg,Monthly Duty Cycle-8000 Pages Power Consumption 960W(Maximum),First Printout Time7.8s / 7.7s (A4 / LTR),Zoom 50 - 200% in 10% Increments Refill Type Toner Cartridge,Internal Memory 64 MB Printer Language UFR II LT (Host Based),Paper Weight 60 to 163g/m2 (Cassette),Copy Speed Up to 18 / 19Cpm (A4 / LTR) Halftones 256 levels,Copy Resolution 600 x 400 DPI Display 7 - Segment,1 - Digit LED as per department incharge 204 Supplying of printer-colour print ,scan,copy all in one printer (Specification :Functions-Print | Scan | Copy,Technology-Inkjet Color output-Color | B&W,Connectivity-Wireless(Wi-Fi) Usage-For Office ,Paper size-A4,Print speed upto 40 pages/min)as per department incharge 205 Supplying of photocopier branded fast print 50ppm high image resolution superior print quality,fast scan up to 50ppm A4 Monocolouras per department incharge 206 Supplying of LAN.Networking,cabling,switches,Wi-Fi points(10 points in each department) as per department incharge 207 Supplying of installation of Printer (Black and white),Printer( colour),Photocopier and LAN,Networking,Cabling,Switches,Wifi Points as per department incharge 208 Supplying of RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio as per department incharge 209 Supplying of Freightof RS+ TT7519RS,RS75+ comes with 75 diagonal length with 3 GB RAM and 48 GB ROM,Slim Glare ,H7 touch surface hardness,Light weight for easy installation,Media suits for Annotation software Bundled with education apps,Office suits ,Great writing experience,Object recognition-First /palm /fine pen ,Touch points -20 points under andriod ,178 degree viewing angle ,IR Touch 15000 14-01-20241 contrast ratio) as per department incharge 210 Supplying of wall mount (Dimension long:Telescopic Adjustable CCTV camera mounting bracket -Color: Beige Universal Camera Bracket, Heavyduty weatherproof iron bracket fits mostbrands of outdoor camera housing,Iron stand Platsic APPLICATION: Ideal for indoor outdoor dome cameras, Security Camera Mount Bracket, high quality with professional design,more stable and reliable.Hidden hole: Cable can feed thru L bracket tothe housing thus provide cable protection Outdoor and Indoor Use.)as per department incharge 211 Supplying of Camcorder Compact full HD ENG Camera with 20X zoom and 5 axis image stabilization. 20X optical zoom (26.8mm, F/1.8-576MM, F/2.;28.8MM, f/1.-576mm). 5 axis image stabilization. Support formats: full HD50P/60P, AVCHD/MP4;SD card slots 2 35mm film camera equivalent when dynamic IS is turned on with Tripod as per Department Incharge 212 Supplying of Video capture and video capture card (Product Specification:Converter type-USB,Material:Metal,Audio Jack:3.5 mm,HDMI Version:Hdmi-1.4,Audio:44100 AU,Video:Full HD Frame:48000 Resolutions)as per department incharge 213 Supplying of UPS(1KVa)(Product Specification: Type-Online UPS,Capacity-1 kVA,Configuration-1 Phase IN - 1 Phase OUT,Protection-OverVoltage,Form Factor-Tower Model Back Up Time-20- 30 Mins,Frequency-40 ~ 70 Hz (auto-sense) Usage/Application All) as per department incharge 214 Supplying of Studio light-125watt,5 LED BULBS consisting of 25watt bulb(Colour Temperature:5500 kelvin)as per department incharge 215 Supplying of Live streaming software for live streaming or live telecast as per department incharge 216 Supplying of Cables,installation,SSD Card(SAMSUNG VNAND SSD 850 EVO 2.5 250GB SATA III 3-D Vertical Internal Solid State Drive (SSD) MZ-75E250B/AM) as per department incharge 217 Supplying of complete making soundproof class(20*20 feet Room) as per department incharge 218 Supplying of RFID Tags RFID Book Lables(specification: Language ‏ : ‎ English,Simultaneous device usage ‏ : ‎ Unlimited Text-to-Speech ‏ : ‎ Enabled,Screen Reader ‏ : ‎ Supported Enhanced typesetting ‏ : ‎ Enabled,X-Ray ‏ : ‎ Not Enabled,Word Wise ‏ : ‎ Not Enabled) as per department incharge 219 Supplying of Anti theft stickers with the university logo(Polycarbonate 175 Microns Matt Finish) as per department incharge 220 Supplying of Middleware Application Desktop(writing and read tags) as per department incharge 221 Supplying of RFID Staff station or desktop reader (used for Tagging of books and circulation) operations through RFID as per department incharge 222 Supplying of Integration with software and Training of complete RFID System as per department incharge 223 Supplying of Data Encoding,Booking Tagging and Registration per book as per department incharge 224 Supplying of RFID Secuity Gates (2 pedestals - 1 gate),RFID Secuity Gate(Provide Installation Service-Yes,Support-24/7 (Live Reporting Language Support-English) as per department incharge 225 Supplying of Automated book drop box (ntegrated RFID Reader • Approx. 250 Books Receiving Cart (Movable) • Client Software for Checking-in Facility and communicating with LMS with provision for E-mail/SMS confirmation • Has automatic hutch which should open only on valid RFID tags and close once the book has been accepted to prevent the patrons from removing checked in books. • Communication with any LMS Software through SIP2/NCIP protocols • Compliant with internationally recognized standards for RFID based library self-services systems. • Book Drop can display item ID once item is returned. • Enabled with necessary items i.e.: Branded CPU etc. • 15” or higher LCD/LED Touch Screen Monitor. • Ethernet High Speed Receipt Printer (Reputed/Branded) • Customizable Design matching the library aesthetics; Contemporary and attractive. • Design is such that there is not damage to the dropped books. • Library Ethernet network and wireless network compliant. • Optional Features: Fingerprint Scanner, Smart Card Readers etc) as per department incharge 226 Supplying of 5KVA Invertor -online UPS with battery back up 100Mah battery (8 units)(Product Specification,Capacity-1100 Voltage-130V ,Rated Input Power-5 KVA,Display-Digital Type-Square Wave Inverter Country of Origin) as per department incharge 227 Supplying of LAN,Switches,Necessary cabling,casing,power supply port including cables as per department incharge 228 Supplying of Installation charges of RFID Tags,Anti-theft sticker,Middleware Application Desktop,RFID Staff statio,Integration of software,Data incoding books,RFID Secuirty Gates,Automated Book Drop Box,Cabling,Casing,Wiring,Switches,LAN as per department incharge 229 Supplying of Air conditioning 1.8Ton heavy duty AC (minimum 3 star rating,Coil material -copper,Power consumption-1950W,Power Requirement -AC 130-285V, 50Hz) as per department incharge 230 Supplying of Desktop,i5 processor ,7th Generation,500GB HDD,4GB RAM,23.8 INCH LED Backlit Monitor,Full HD IPS Panel(Brand-HP,Dell,Acer) as per department incharge 231 Supplying of Headphone with built in microphone,(Communication-Wired) as per department incharge 232 Supplying of 75 diagonal length with 3 GB RAM and 48 GB ROM ,Slim frame anti glare glass.3M Antiglare ,H7 Touch surface hardness,Light weight for easy installation as per department incharge 233 Supplying of Dedicated server-HPE Proliant DL 380,Gen 10 5218.2.3GHz 16core ,1P-32GB-R P408ianNC 8SFF 800WPS Server,Intel xeon G5218 Kit for DL 380,Gen 10 as per department incharge 234 Supplying of 5.5KVA Inverter with battery backup,Microtek inverter,online UPS ,65Mah battery(16 unit )-Exide as per department incharge 235 Supplying of Freight Transportation Charges of Desktop,Headphone,LAN Switches,4K-OPS,Dedicated server,5.5 KVA Inverter with battery back up and Air conditioner as per department incharge 236 Supplying of 86 Diagonal interactive display,3 GB RAM,48 GB ROM,4K Display Android model,Slim framenAnti glare Glass,H7 Touch Surface hardness ,Light weight for easy installation ,Media Suits for Annotation softwatr bundled with education Apps as per department incharge 237 Supplying of 4k OPS i5,7th Gen,8GB RAM,128 GB SSD as per department incharge 238 Supplying of play mounting including white board & Green board,Material post formed ply,Size 15ft(length)x7ft(ht) with green board for chalk,whiteboard for marker and cupboard as per department incharge 239 Supplying of UPS (1KVa,Phase-Single phase.Back up Time 10-20 min,Frequency-50Hz) as per department incharge 240 Supplying ofTraining and installation of 86 diagonal interactive display,4k-OPS,Play mounting including white board & Green board and UPS of 1KVA as per department incharge 241 Supplying of Digital Podium PTGN 500 Windows 8.1 LCD ,Electronic Lectern,On site OEM Warranty in 3 yearsas per department incharge 242 Supplying of PA System sound system with amplifier 350 watt ,30 watt speaker (4 nos) as per department incharge 243 Supplying of wireless mic Dual channel cordless microphone as per department incharge 244 Supplying ofTraining and installation of Digital Podium,86 Diagonal interactive display (4k display),4K-OPS,Play mounting including white board and green board,5KVA invertor,PA System and wireless mic as per department incharge 245 Supplying of Desktop :- 1).i5 Processor, 7th Generation, 500GB HDD, 4GB RAM, 2).23.8 inch. LED backlit Monitor Full HD IPS Panelas per Department Incharge 246 Supplying of 55 LED Display for CCTV Branded LED Display as per department incharge 247 Supplying of CCTV Camera IP based CCTV camera,2 TB Space with NVR with necessary accessories as per department incharge 248 Supplying of Stagmometer as per Department Incharge 249 Supplying ofViscometer as per Department Incharge 250 Supplying of Beaker-50ml as per Department Incharge 251 Supplying of Beaker-100ml as per Department Incharge 252 Supplying of Beaker-250ml as per Department Incharge 253 Supplying of Beaker-500ml as per Department Incharge 254 Supplying of Beaker-1000ml as per Department Incharge 255 Supplying of Buchner Funnel 3 as per Department Incharge 256 Supplying of Buchner Funnel 6as per Department Incharge 257 Supplying of Burette-50ml as per Department Incharge 258 Supplying of Chromatography column 1x18 with stop cock as per Department Incharge 259 Supplying of Conical flask-100ml as per Department Incharge 260 Supplying of Conical flask-250ml as per Department Incharge 261 Supplying of Conical flask-500ml as per Department Incharge 262 Supplying of Conical flask-1000ml as per Department Incharge 263 Supplying of Flat Bottomflask-500ml(Round) B-24 socket as per Department Incharge 264 Supplying of Round bottom flask-50ml Joint B-24 as per Department Incharge 265 Supplying of Round bottom flask-100ml Joint B-24 as per Department Incharge 266 Supplying of 3 neck RB flask B-29,B-19.as per Department Incharge 267 Supplying of Condenser Spiral B-24 and, B-19 as per Department Incharge 268 Supplying of Condenser Spiral B-24 and, B-24 as per Department Incharge 269 Supplying of T-type tube as per Department Incharge 270 Supplying of Rubber Cock No. 10 as per Department Incharge 271 Supplying of Specific Gravity hydrometer 800-1000 as per Department Incharge 272 Supplying of Specific Gravity hydrometer 100-1200 as per Department Incharge 273 Supplying of Universal hydrometer 1000-2000 as per Department Incharge 274 Supplying of Measuring Cylinder-10ml as per Department Incharge 275 Supplying of Measuring Cylinder-50ml as per Department Incharge 276 Supplying of Measuring Cylinder-100ml as per Department Incharge 277 Supplying of Measuring Cylinder-500ml as per Department Incharge 278 Supplying of Measuring Cylinder-1000ml as per Department Incharge 279 Supplying of Measuring Cylinder-2000ml as per Department Incharge 280 Supplying of Measuring flask-100ml as per Department Incharge 281 Supplying of Measuring flask-500ml as per Department Incharge 282 Supplying of Measuring flask-1000ml as per Department Incharge 283 Supplying of Pipette-0.5ml as per Department Incharge 284 Supplying of Pipette-2ml as per Department Incharge 285 Supplying of Pipette-5ml as per Department Incharge 286 Supplying of Pipette-10ml as per Department Incharge 287 Supplying of Pipette-25ml as per Department Incharge 288 Supplying of Separating Funnel-250ml B-24/B-24 as per Department Incharge 289 Supplying of Spatula Flat Spoon 6as per Department Incharge 290 Supplying of Spatula Flat Spoon 5as per Department Incharge 291 Supplying of Stop Cork 2wayas per Department Incharge 292 Supplying of Silica crucible-15ml without Lid as per Department Incharge 293 Supplying of Silica crucible-25ml without Lid as per Department Incharge 294 Supplying of Stalagmometer Straight Graduated as per Department Incharge 295 Supplying of Chemical thermometer 10c-110c as per Department Incharge 296 Supplying of Chemical thermometer 0c-250c as per Department Incharge 297 Supplying of Tiration flask-100ml as per Department Incharge 298 Supplying of Tiration flask-250ml as per Department Incharge 299 Supplying of Tongs crucible S.S.8 as per Department Incharge 300 Supplying of Test tube holder as per Department Incharge 301 Supplying of Filter Flask-500ml as per Department Incharge 302 Supplying of Filter Flask-1000ml as per Department Incharge 303 Supplying of Watch glass 3 as per Department Incharge 304 Supplying of Watch glass 4 as per Department Incharge 305 Supplying of Watch glass 6 as per Department Incharge 306 Supplying of Wire gauge150x150mm as per Department Incharge 307 Supplying of Tripod stand 8 as per Department Incharge 308 Supplying of boiling Test tube 1x8as per Department Incharge 309 Supplying of boiling Test tube 2x8as per Department Incharge 310 Supplying of Reagent Stickers 2x1 as per Department Incharge 311 Supplying of Ordinary Filter paper as per Department Incharge 312 Supplying of Reagent bottles-250mlas per Department Incharge 313 Supplying of Rubber cork as per Department Incharge 314 Supplying of Rubber tube 6mm as per Department Incharge 315 Supplying of Solid Reagent bottle-125mlas per Department Incharge 316 Supplying of Stopwatch plastic body as per Department Incharge 317 Supplying of Test tube stand 12 holes as per Department Incharge 318 Supplying of Thermometer 360 as per Department Incharge 319 Supplying of Test Tube 6mmx15cmas per Department Incharge 320 Supplying of Test Tube 10mmx10cm as per Department Incharge 321 Supplying of China dish 3 as per Department Incharge 322 Supplying of China dish 4 as per Department Incharge 323 Supplying of Brushes for Test Tube as per Department Incharge 324 Supplying of Brushes for Burette as per Department Incharge 325 Supplying of Brushes for Conical flask as per Department Incharge 326 Supplying of LPG gas burner as per Department Incharge 327 Supplying of Condenser Coil 12 as per Department Incharge 328 Supplying of Receiving adopter with vacuum outlet as per Department Incharge 329 Supplying of Plastic Wash bottle-500mlas per Department Incharge 330 Supplying of Pastel and Mortar 3 as per Department Incharge 331 Supplying of Pastel and Mortar 4 as per Department Incharge 332 Supplying of Pastel and Mortar 6 as per Department Incharge 333 Supplying of China Clay 2 as per Department Incharge 334 Supplying of China Clay 3 as per Department Incharge 335 Supplying of China Clay 4 as per Department Incharge 336 Supplying of Petri Dish 3(Borosil) as per Department Incharge 337 Supplying of Petri Dish 4(Borosil) as per Department Incharge 338 Supplying of Distillation Set-Complete flask-500ml as per Department Incharge 339 Supplying of Distillation Set-Complete flask-1000ml as per Department Incharge 340 Supplying of Thermometer Pocket B-14 as per Department Incharge 341 Supplying of Sintered Glass Funnel-25ml as per Department Incharge 342 Supplying of Air Condenser 12 as per Department Incharge 343 Supplying of Burette Stand with Clamp as per Department Incharge 344 Supplying of Cork borer as per Department Incharge 345 Supplying of Capillary Tube for melting point as per Department Incharge 346 Supplying of Dessicators 6 as per Department Incharge 347 Supplying of Dessicators 8 as per Department Incharge 348 Supplying of Dropper with Rubber teats 6 as per Department Incharge 349 Supplying of Dropper 4(Borosilicate glass) as per Department Incharge 350 Supplying of Dropping bottle-125ml as per Department Incharge 351 Supplying of Funnel Stand as per Department Incharge 352 Supplying of Fusion Tubeas per Department Incharge 353 Supplying of Glass Rod as per Department Incharge 354 Supplying of Glass Tube as per Department Incharge 355 Supplying of Stopwatch Steel body as per Department Incharge 356 Supplying of Magnetic Stirrer as per Department Incharge 357 Supplying of Rubber Gloves as per Department Incharge 358 Supplying of Reagent as per Department Incharge 359 Supplying of Sandbath as per Department Incharge 360 Supplying of Tissue Paper(Local made) as per Department Incharge 361 Supplying of Double Beam PC Microprocessor UV-VIS Spectrophotomet erMake:Systroni cs Model: 2202 PC Based Double Beam Automatic source optimization ,Base line calibration & Cell optimization 200 - 1100 nm Range2. 0 nm Bandwidth%T. Abs. Conc . (K factor. Multi standard ). Multi component measuring modesSingle Wave length, Multi Wave length Scan (with multi scan facility). Time Scan. Kinetic scan operating modes Automatic 5 position sample changer Single Position 50 /100 mm Cuvette Holder (Optional) as per Department incharge 362 Supplying of Refrigerated Centrifuge,(Specification:Speed:- 20000 Max.,RCF:- 37570 Max.,Lowest Temp:- -8,Noise:- <-60db)as per Department incharge 363 Supplying of Refrigerated Centrifuge Essential accessories Required:. With angle Heads (with polypropylene tubes)Model- R-248M 24xl.5 ml as per Department incharge 364 Supplying of Refrigerated Centrifuge 2. Voltage stabilizer:- 03 KW Servo controlled Voltage Stabilizer, input 170 volts to 260 volts, output 220 volts to 240volts as per Department incharge 365 Supplying of PCR machine(Specification- Well block, Gradient, temp. range 4° - 99-irC, memory capacity 10000 protocols , display 7inch,volume capacity I 0- 100 μL , preloaded protocol, temperature accuracy ±0.2°C@99°C, with PCR wizard as per Department incharge 366 Supplying of SOS PAGE unit and Western Blot apparatus along with power bank -Mini-TBC electroph_oretic transfer cell, includes: Mini 01P-4 cell tank and lid with cables, buffer, Mini transfer module, gel holder cassettes, 4 fiber pads, cooling units, instructions, Western blot unit, compatible power bank as per Department incharge 367 Supplying of pH Meter With electrode(Type of PH Mater - Portable,Ph Range:0-14,Resolution-0.01pH,compensation-0 to 80 degree celsius) as per Department incharge 368 Supplying of Deep fridge(It is used to store chemicals and preserve samples at very low sub-zero temperatures or below)as per Department incharge 369 Supplying of Autoclave (Vertical)Size- 400 x 600mm ,;Capacity- 75Ltr as per Department incharge 370 Supplying of Hot air oven (Sterilization) as per Department incharge 371 Supplying of Incubator Shaker-Growth and enumeration of microbes (Broth cultures) as per Department incharge 372 Supplying of Horizontal Laminar air flow(Sterile environment Size 4X2)as per Department incharge 373 Supplying of Horizontal Agarose gel electrophoresis unit with gel caster and Power pack Separation of macromoleculeas per Department incharge 374 Supplying of Vortex mixture-To mix content of test tubes and microfuge tubes. as per Department incharge 375 Supplying of Ultrapure Water Purification System:MiliQ Water For distill wateras per Department incharge 376 Supplying of Micropipets - 0.1μL-2.5μL 0.5μL-10.0μL 10.0μL-l00μL 20.0μL-200μL l00μL-l000μL as per Department incharge 377 Supplying of Quebec Colony Counter -Count the microbial colonies as per Department incharge 378 Supplying of Light Microscope (General) 10X,20x, 45x, l00x Visualize microorganisms as per Department incharge 379 Supplying of Bifocal microscope with illuminators, Camera attachment and computer Visualize microorganisms and microgrphy as per Department incharge 380 Supplying of Magnetic stirwith Hotplate and magnetic beads To stir the liquids , preparation of solution as per Department incharge 381 Supplying of Heating mantle For heating round bottomed flask/distillation flask as per Department incharge 382 Supplying of Microwave oven To heat liquids instead of flaming. Samsung/ LG 20 Ltrs as per Department incharge 383 Supplying of Glass Dessicators Used for dessication as per Department incharge 384 Supplying of Fluorescence microscope A fluorescence microscope is an optical Microscope that uses fluorescence and phosphore scence instead of,or in addition to, reflection and absorption to study properties of organic or inorganic substances as per Department incharge 385 Supplying of Electronic Analytical Balance It is used to weigh small quantities of chemicals and samples precisely and quickly. Readability- 1 mg (0.001 g) Cap.- 420gm as per Department incharge 386 Supplying of Electronic Top pan Balance- Readability- 0.1 g Cap.- 2 kg.as per Department incharge 387 Supplying of Double Distillation Unit ,.Approx output: 2 Lit/hrs Wattage:3.3 .KW With safety Cutoff Device Water Stills are carefully designed to produce high purity pyrogen free distiiied water. The water still comprises ofborosilicates glass horizontal typeboiler, coil condenser, constant level device, silica sheathed heaters, along with stand and clamps. All parts are replaceable. pH/conductivity:6-7 / 1-2 μSiem forsingle, 6-7/0.8-lμS/cm for double distilled water as per department incharge 388 Supplying of Microtome-5286(Product Specification Minimum Setting Value-0.5 um,Object Feed-28 mm,Vertical Stroke-60 mm,Specimen Orientation X and Y Axis Universal 8 Degree Trimming Thickness Range-1 um-100 um Operation-Automatic. (Motorized Feed & sectioning and Emergency Stop Provided),Sectioning Speed-0-400 mm/sec.,Specimen-Orientation Z Axis-Upto 360 Degree,Retraction Value-Adjustable Max Specimen Size-50 x 50 mm,Section Thickness Range-0.5 um-60 um)Senior rotary microtome as per Department incharge 389 Supplying of Cryostat -(Product Specification Section Thickness Range-0.5 Micron to 100 Micron (with the increment of 0.5 Micron, 1 Micron, 2 Micron, 5 Micron) Power Supply-220v,Dimension-750mm x 750mm x 950mm (approx) Weight -123 kg (approx),Remote Control-Optional,Sectioning Mode-Single step mode/ Continuous mode Hand Wheel Control-Feather Touch Keypad/ Foot Switch/ Remote Control (optional),Sterilization-U.V-C Sterilization,Cooling down time Up to -30 DegreeC-2 Hour 30 Min Specimen Retraction setting Range-5 Micron to 100 Micron (with increment of 5 Micron),Compressor-Dual Compressor,Cryo Chamber Temp. Adjustable -1 DegreeC to -30 DegreeC Block Holder Head Temperature-Adjustable -1 DegreeC to -35 DegreeC Illumination-LED Lamp)Ultimate usico fully automatic cryostat as per Department incharge 390 Supplying of ELISA -Vet scientific(Specification-Product Specification Automation-Semi Automatic,Assays Performed-ELISAs, Immuno Assays Plate Format-96 well,Optical System Filter-based Detection Method-Absorbance,Number Of User Programs 42 Storage-100000 Results,Filter Positions-8 Display Type-Touch Screen Packaging Type-EXPORT QUALITY,Testing Speed-3 second Type Of Filter 405,450,492, 630,Power Source-115/230 V AC, 50Hz,Weight-9 Kg,Is It Portable-Non Portable, sample Type-Serum, Plasma, Urine, CSF, Whole Blood,sample Volume Range-10-100 Interface-RS232/ USB) as per Department incharge 391 Supplying of Calorimeter -A VI Digital (A VI Scientific,Frequrcy:50Hz,Voltage:230-280V,operating time per test-10 min) as per Department incharge 392 Supplying of HaemometerSahli type-Microsidd (Specification:Amber coloured glass bottle -1 No.,Glass Stirrer-1 No.,Dropper with teat -1 No.,Cleaning Brush -1 No.,Spare latex tubing one meter -1 No.Round tube haemoglobinometer) as per Department incharge 393 Supplying of Anti - theft Sticker with the University logo as per Department incharge 394 Supplying of Middleware Application Desktop(Write and Read Tags) as per Department incharge 395 Supplying of RFID Staff Station or desktop reader (Used for tagging of books and circulation {lssue/Return) operations through RFID) as per Department incharge 396 Supplying of Integration with Software and Training of Complete RFID System as per Department incharge 397 Supplying of RFIDSecurityGates (2 pedestals-1 gate) RFID Security Gate (Single Lane) as per Department incharge 398 Supplying of Automated Book drop Box as per Department incharge 399 Supplying ofCabling. Casing. Wiring , Switches as per Department incharge 400 Supplying of Freight Transportation of Miidle ware Application Desktop,RFID STAFF Station,Integration with software training,Automated Drop box ,Cabling,Casing,Wiring,Switches as per Department incharge 401 Supplying of LAN . Switches, Necessary Cabling, Casing , Power Supply port including cables as per Department incharge 402 Supplying of Dedicated serverGHZ 16 core 1P-32GB -RP408ia -NC8SFF800WPS Serverintel Xeon -G5218 Kit for DL 380 GEN-10-HPE 32GB 2RX4 PC-4 2933YR Smart kit ,HPE DL38x Gen 10-12 Gb SAS Expande,HPE DL 380Gen 10 Box 1/2 Cage Bkpin kit ,HPE 24TB SAS 12G 10K SFF SC 512eDS HDD .HPE 800 WFS Ht Plg LHPwr Sply kit,HPE 3 Year Fiundation care 24x7 DL 380 Gen 10 Serviceas per Department incharge 403 Supplying of RS 86+_TB619RS, 3GB RAM and 48 GB ROM,4K Display Android model,3 GB RAM And 48 GB ROM,slim frame,Anti Glare Glass,3M Anti glare H7 Anti touch surface hardness lightweight for easy installation,Media suits for Annotation,Software bundled with education apps,Office suits,Great writing experience,Object recognition -First pal,/Fine pen ,Touch Points-20 points under window and 10 points under android,178 degree viewing angle IR ,Touch 15000,1 contrast ratio,4 MS Response time 50000 hours life,Reduce clutter and bring efficiency for the faculty,Remote control,15 wattX2 speaker,Android 8.0,Newline cast,Display management,Newline broadcast including installation and Trainingas per Department incharge 404 Supplying of Deep Fridgeas(2 in 1 Converti Freezer & Cooler Corrosion Resistant Cooling Coil & PPGI for inner & outer body Heavy Duty Compressor & Tropicalised Design Approximately 14% Higher Net Capacity compared to competition Sleek Design with heavy duty performance) per Department Incharge 405 Supplying of Autoclave (Horizontal,Height X Dia: 450mm x 250mm Height x Dia: 18Inch x 10Inch,Capacity: 22 Ltr,Load: 2.0 KW) as per Department Incharge 406 Supplying of Autoclave (Vertical): size- 400x600mm, Capacity- 75Ltr as per Department Incharge 407 Supplying of Hot air oven(Standard double wall fabrication. Inner chamber made of highly polished stainless steel sheet. Exterior fabricated out of thick mild steel sheet duly finished in stove enamel off-white paint or paste mat finish colour combinations.Nichrome wire heating elements -provided on three sides attain quick and uniform heating in range of 50c to 250c + 1c controlled by capillary type thermostat.Inner Chamber Size 18x18x18 inch. made of Stainless Steel) : any Standard make as per Department Incharge 408 Supplying of Bacteriological incubator(Item Weight ‎10 kg Product Dimensions-30 x 30 x 30 cm; 10 Kilograms,Item model number-12X12,Item Height-30 Centimeters Item Width-30 Centimeters) as per Department Incharge 409 Supplying of Bacteriological shaking incubator as per Department Incharge 410 Supplying of BOD incubator as per Department Incharge 411 Supplying of Laminar air flow any Standard company as per Department Incharge 412 Supplying of Micropipettes with microtips :(1.0uL-10.0uL, 10.0uL-100uL, 100uL-1000uL, 20uL-200uL): A. Prime Variable Pipette, B. Fully Autoclaveable Variable Vol. Pipetteas per Department Incharge 413 Supplying of Colorimeters with cuvettes any Standard company as per Department Incharge 414 Supplying of Western Blot apparatus, as per Department Incharge 415 Supplying of Powerpack with wiresas per Department Incharge 416 Supplying of Homogeniser as per Department Incharge 417 Supplying of PCR machine Block Formats 96x0.2ml(A),54x0.5ml(B), 96x0.2ml +77x05ml©, 384well(D) Size(WxDxH,mm)-380x270x250 as per Department Incharge 418 Supplying of UV Transilluminator/UV chamber UV source: 365nm Wave Length Viewing area: 24x14cm Anti Slip rubber foot provided for base as per Department Incharge 419 Supplying of CO2 incubator as per Department Incharge 420 Supplying of pH meter and buffers: A.pH meter B. pH buffers as per Department Incharge 421 Supplying of Water bath (any Standard company ) as per Department Incharge 422 Supplying of Fume Hood: size- 3x3x2 wooden with Granite working area as per Department Incharge 423 Supplying of Soxlet apparatus with heating mantle and distillation set up as per Department Incharge 424 Supplying of Kjeldahl Apparatus as per Department Incharge 425 Supplying of Ultrapure Water Purification System: MiliQ water as per Department Incharge 426 Supplying of Quebee Colony Counter as per Department Incharge 427 Supplying of Light Microscope (general) 25x, 45x, 100x s as per Department Incharge 428 Supplying of Bifocal microscope with illuminators as per Department Incharge 429 Supplying of Magnetic stirrer with magnetic beads(any Standard company )as per Department Incharge 430 Supplying of Magnetic stirrer with hot plate (Remi) as per Department Incharge 431 Supplying of Heating mantleas per Department Incharge 432 Supplying of Microwave oven ((20Ltr) as per Department Incharge 433 Supplying of Glass Dessicators as per Department Incharge 434 Supplying of Computer : Core i9, 7th Gen. 20 LED Monitor, 4GB DDV, 1TB HDD, DV writer HP/Dell as per Department Incharge 435 Supplying of Culture room: Tissue culture Rack fitted with 16 tubes, 8 bulbs, 4UV & Timer as per Department Incharge 436 Supplying of Electronic Analytical Balance:- Readability- 1mg(0.001g) Cap.-420gm as per Department Incharge 437 Supplying of ElectronicTop-pan Balance:-Readability- 0.1g Cap- 2kgas per Department Incharge 438 Supplying of Electroporator:- as per Department Incharge 439 Supplying of Fermenter(7.5L)(any Standard company )as per Department Incharge 440 Supplying of Fluorescence Microscopeas per Department Incharge 441 Supplying of Hot air oven universalas per Department Incharge 442 Supplying of Distillation Unit as per Department Incharge 443 Supplying of Membrane filter assembly 5000 mlas per Department Incharge 444 Supplying of Fluorimeter as per Department Incharge 445 Supplying of Homogeniser: Remi model- RQT-127 A/D High speed homogenizer, with 1/8 HP Motor, Homogenizer Working Volume [H2O] 0.1-50ml (Dispersing shaft DS-160/5) WEIGHT 0.6KG Dimension[LxWxH] 46mmx55mmx230 operating environment 0-40degre, 85% rel. humidity as per Department Incharge 446 Supplying of ELISA reader and Microtitre plates: ELISA Wavelength range 400nm-800nm Accuracy- +-1% at 1.0OD, 450nm Dimension 450x350x197mm as per Department Incharge 447 Supplying of Liminar air flow : 4x2x2 feet, stainless steel as per Department Incharge 448 Supplying of Gel Documentationd system as per Department Incharge 449 Supplying of 5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 450 Supplying of 12V/26AH- Batteryas per Department Incharge 451 Supplying of Headphone with built in microphone (Brand) as per Department Incharge 452 Supplying of Furniture:- Computer Table & Chairs & Table- Chair for lab. Instructor and student (50 students per batch) as per Department Incharge 453 Supplying of Network:- LAN, Switches, Cabling, Casing Power Supply Port including Cables as per Department Incharge 454 Supplying of 5.5 KVA Inverter with Battery Backup. Microtek inverter, online UPS 65Mah Battery (16 units) -Exide as per Department Incharge 455 Supplying of RS86+ TT8619RS 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0, Newline Cast, Display Managemen, Newline Broadcast Including Installation and Training. as per Department Incharge 456 Supplying ofpH meter(Digital) :- pH range: 0-14, Temperature Range: 0.0 to 100 C (Manual Compensation) as per Department Incharge 457 Supplying ofNoise Level meter:- Auto/Manual ranging from 30 to 130dB in 6 ranges as per Department Incharge 458 Supplying ofWater analysis Kit:- They include; alkalinity, chloride, hardness, iron, and sulphate as per Department Incharge 459 Supplying ofHigh volume sampler:- 1)PM-2.5- Designed to meet International Standards for High volume air Sampling of PM2.5 particulates. 2)PM-10-U.S EPA FRM Designed for the determination of suspended of PM-10 particulates concentrations. (RFPS-1287-063) 3)TSP- Designed to meet U.S EPA reference method for determination of total suspended particulates(TSP) concentration as perDepartment Incharge 460 Supplying ofSoil testing kit (mrinda parikshan kit) : Use for micro and macro nutrients as per Department Incharge 461 Supplying ofSeive plate with shaker : 5mm,1mm,2mm) as per Department Incharge 462 Supplying ofUV/Visible spectrophotometer:- Spectral bandwidth 1 nm (190 to1100nm , Lamp Type 20-W halogen lamp and deuterium lamp as per Department Incharge 463 Supplying ofAutoclave : 10-15 litre Steam Sterilizer as per Department Incharge 464 Supplying ofLaminar hood (Horizantal) : Horizontal air flow cabinet, filter air blow across the work zone in horizontal direction. This constant flow of air provides material and product protection as per Department Incharge 465 Supplying ofHot plate(pic):-Temperature range: 350 C as per Department Incharge 466 Supplying ofShakeer incubator Compact Bench top shaker with temperature control range from Ambient +50C to 600C. Tray dimension : 420x420 , Speed 50-350 rpm with accuracy of +/- 2rpm as per Department Incharge 467 Supplying ofMuffle Furnaces (15x125x250)cm: Temperature upto 35C to 1400C as per Department Incharge 468 Supplying of Analytical Balances:Capacity 220gram as per Department Incharge 469 Supplying ofDigester : 1) vessel size : Dia 39 mm (Aprox.); Volume 160ml 2)Temperature : upto 200degC as per Department Incharge 470 Supplying ofDouble distilled water plant: Model- Vertical:- Distlled Water Output Capacity-2.5 Litres/Hours, Distillate water quality as per Department Incharge 471 Supplying ofOven:- Dry ovens- 30 to 1000 litre capacity. as per Department Incharge 472 Supplying of B.O.D Incubator: Volume 68 Litre as per Department Incharge 473 Supplying ofMagnus Microscope:- Magnification 4x,10x,40x, and 100x as per Department Incharge 474 Supplying ofDesiccators:- Contain: Silica Gel dimension;12x12 in (30.5x30.5 cm),Material Glass as per Department Incharge 475 Supplying ofRichter scale hardness tester Portable Rockwell/brinell vickers Hardness Testing Instrument Mold metal hardness meter display:-parameter- HRC Display Type, Digital Model Name/Number- ATedigiHR, Accuracy- 0.1 HRC Dimensions of Machine base (approx.) 150x425 mm as per Department Incharge 476 Supplying ofProctor Penetrometer: Proctor Penetrometer- Complete with set of needle points Weight, 2 kg as per Department Incharge 477 Supplying ofGas Chromatography Retention time repeatability-< 0.008% or 0.0008 min Area rpeatability -<1% RSD, using 2ng tetradecane as per Department Incharge 478 Supplying of Atomic Absorption Spectrometry(AAS):- aa-7000 SERIES OF Atomic Absorption Spectrophotometers features high- sensitivity analysis as per Department Incharge 479 Supplying ofWavelength range; 400 to710nm Wavelength selection: 8 in-built gelatin filters: 430,470,490,520,540,580,600 and 710 nm Measurement ranges; 0-100%T, 0-1.50Abs, 0.1 to 1000 Concentration. Resolution: 1%T, 0.01Abs, 0.1 to 1 Concentration as per Department Incharge 480 Supplying of Laptops(of Specification:Processor Corei5,RAM:4GB,Hard drive:500GB ,Screen size:12 inch):as per Department Incharge 481 Supplying of Desktops: i7 3rd Gen, 1TB HDD, 4GB RAM, Windos 10, MS office, Graphics card as per Department Incharge 482 Supplying of Xerox Machine(Product Specification:Functions Multi-Function:Supported Paper Size-A3,Supported OS-all,Color Output-Black & White,Number Of Trays-4,Item Color-white and blue Print Speed-up to 35 ppm,Weight 129 kg,Print Technology-Laser Warm-Up Time, As fast as 11 seconds (black and white) Duty Cycle-WorkCentre 5335: Up to 150,000 pages / month Resolution-200 x 1200 dpi) as per Department Incharge 483 Supplying of Air Conditioning:-1.5 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 484 Supplying of Luminous Cruze 3.5KVA Inverter with RC 18000 Battery (4 Batteries) as per Department Incharge 485 Supplying of Projector(Special Feature-portable,Connectivity Technology,Bluetooth, Wi-Fi, USB, HDMI,Display resolution 1920 x 1080,Display Type-LED) as per Department Incharge 486 Supplying of Godrej Lecture Hall Furniture as per Department Incharge 487 Supplying of Electronic Podium(Speaker type-Tweeter,Auxillary,wireless,floor standing) as per Department Incharge 488 Supplying of Smart board (Screen size-11 inches,Connecting technology-Wifi,Multimedia)as per Department Incharge 489 Supplying of Black board( Melamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS CornersMelamine Writing Surface (Chalk), Paper Honeycomb Core, 6063-T6 Alloy Aluminium Frame & Virgin ABS Corners) as per Department Incharge 490 Supplying of Glassware rack as per Department Incharge 491 Supplying of installation of Air conditioner,Luminous Cruze,Projector,Lecture Hall Furniture,Electronic podium,Smart board and black board as per Department Incharge 492 Supplying of Inductively coupled Plasma - Optical Emission Spectrometer with CID detector technology for multi-element analysis of geological petrogical etc. samples in ppb level as per Department Incharge 493 Supplying of Suppressed ion analysis system for anion and cation analysis in water, wastewater, environmental samples and also upgradable to combustion for determination of corrosive halogens and sulfur in Petrochemicals, gaseous samples, solid samples, and complex samples as per Department Incharge 494 Supplying of CHNS/O for the analysis of Carbon, Hydrogen, Nitrogen, Sulfur and Carbon in organic matrices, soil, feed , plant samples, petroleum products, Coal, Coke, Biomass & Liquid Fuels as per Department Incharge 495 Supplying of Gas Analyzers for hydrocarbon and permanent gas analysis as per Department Incharge 496 Supplying of Benchotop XRD as per Department Incharge 497 Supplying of XRF Spectrometer as per Department Incharge 498 Supplying of Refrigereted Centifuge MakE-REMI, Model-C24 PLUS :- Max. Speed:20000, Max. RCF:3757, Max. Lowest Temp.:8, Noise:60db. Essential accessories Required: 01. Withangle Heads (with polypropulene tubes) Model-R-248M24x1.5ml 2)Voltage stabilizer:-03KW Servocontrolled Voltage Stabilizer, input 170volts to 260volts, output 220 to 240volts as per Department Incharge 499 Supplying of pH Meter compatible poer bank Make: REMI :- With eletrode as per Department Incharge 500 Supplying of Bench top Centrifuge Make: Tarson, : - SPINWIN MC-001 6 places Rotor for 1.5 ml tubeas per Department Incharge 501 Supplying of Deep Fridge: It is used to store chemicals and preserve samples at very low sub-zero tempertures or below as per Department Incharge 502 Supplying of Autoclave(Vertical) : size- 400x600mm capacity- 75Ltr as per Department Incharge 503 Supplying of Hot air oven : Sterilization as per Department Incharge 504 Supplying of Incubator Shaker: Growth and enumeration of microbes(Broth Cultures) as per Department Incharge 505 Supplying of Horizontal Laminar air flow:- Sterile environment size 4x2as per Department Incharge 506 Supplying of Ultrapure Water Purification System: MiliQ Water : for distil water as per Department Incharge 507 Supplying of Micropipets (Ependroff): 0.1uL-2.5uL, 0.5uL-10uL, 10.0uL-100uL, 100uL-1000uL each oo these 1pcs as per Department Incharge 508 Supplying of Light Microscope (general)10X, 20X, 45X, 100X, : Visualize microorganisms as per Department Incharge 509 Supplying of Bifocalcal Microscope with illuminators, Camera Attachment and comput: Visuallize microorganisms and micrography as per Department Incharge 510 Supplying of Magnetic stir with Hotplate and magnetic bead as per Department Incharge 511 Supplying of Heatingmant; for heatinground bottomed flask/distillation flask as per Department Incharge 512 Supplying of Microwave oven: To heat liquids instead of flaming. 20Ltrs as per Department Incharge 513 Supplying of kydroPro 100 handeld multiparameter water quality analiser: Turbedityas per Department Incharge 514 Supplying of Petrological Microscope: Study of Optical minrology as per Department Incharge 515 Supplying of Ore petrological microscope: Study of ore petrology as per Department Incharge 516 Supplying of Miscellaneous instruments as per Department Incharge 517 Supplying of glassware as per Department Incharge 518 Supplying of chemical as per Department Incharge 519 Supplying of Arc GIS(Latest) as per Department Incharge 520 Supplying of GCD Toolkits as per Department Incharge 521 Supplying of SURPAC Software as per Department Incharge 522 Supplying of Intergraph Edu Kit [GIS+RS] Version 2020 or latest(Software content as per list), 5 users for Erdas imagine Professional and 5 users for Geomedia professional Software as per Department Incharge 523 Supplying of Interactive Flat Panel as per Department Incharge 524 Supplying of 2 Virtual Class Room including capture, recording and streaming online, 1 Servers one per 05 classrooms per Department Incharge 525 Supplying of N-computing for smart classrooms including servers and clients as per Department Incharge 526 Supplying of Tagging of documents(books/hard-bound journals/CDs/technical films etc)in RFID Technology as per Department Incharge 527 Supplying of Sofwares, Server Machines, Air-Conditioning Systems,Xerox Machines, Lamination Machines, Binding Machines, Furniture/Furnishing, Computers, Printers etc as per Department Incharge 528 Supplying of Digital Podium, PTGN 500, Window & 1 LCD, Elecronic Lectern, on site OEM. Warranty 3years, 3GB RAM,4GB ROM as per Department Incharge 529 Supplying of Air Conditioning:-1.8 Ton heavy duty AC (mimimum 3 Star rating) as per Department Incharge 530 Supplying of Black/ White,Printer:- scan-copy all in printer- Branded as per Department Incharge 531 Supplying of CCTV set for floor: 55 LRD display for CCTV. CCTV Camera-1 P based CCTV camera 2TB space with NVR with necessary accessories as per Department Incharge 532 Supplying of 5KVA Inverter online UPS with battery backup 100Mah battery(8 units) as per Department Incharge 533 Supplying of Electrophoresis Apparatus as per Department Incharge 534 Supplying of Bacteriological Incubator as per Department Incharge 535 Supplying of Autoclave as per Department Incharge 536 Supplying of Centrifuge as per Department Incharge 537 Supplying of Rotar Head as per Department Incharge 538 Supplying of Rotar Head 25 as per Department Incharge 539 Supplying of Gel documentation system as per Department Incharge 540 Supplying of Spectrophotometers as per Department Incharge 541 Supplying of compoud Microscope as per Department Incharge 542 Supplying of Trinocular Microscope with camera as per Department Incharge 543 Supplying of Semi-Automated Microtonne as per Department Incharge 544 Supplying of DNA Sequencer as per Department Incharge 545 Supplying of Spectrophotometer as per Department Incharge 546 Supplying of Laminar air flow chamber as per Department Incharge 547 Supplying of Tissue culture rack as per Department Incharge 548 Supplying of PCR Apparatus as per Department Incharge 549 Supplying of Liquid nitrogen cylinder as per Department Incharge 550 Supplying of TLC apparatus kit as per Department Incharge 551 Supplying of TLC Visualizer/documentation as per Department Incharge 552 Supplying of HPLC System as per Department Incharge 553 Supplying of Scientific vortex mixer as per Department Incharge 554 Supplying of Soil Thermometer as per Department Incharge 555 Supplying of Scientific Digital Balance as per Department Incharge 556 Supplying Equipments for workshop,Seminar & Excrusion as per Department Incharge 557 Supplying Equipments for Non-Recurring(Research Equipment) as per Department Incharge 558 Supplying Equipments for Recurring(Chemical & Glassware) as per Department Incharge 559 Supplying of Furniture Bookshelves, Study Tables and Chairs for Readers as per Department Incharge 560 Supplying of Desktop i5 Processor, 7th Generations, 500GB HDD, 4GB RAM, 23.8 inch, LED backlit Monitor Full HD IPS Panel (Brand: HP/DELL) as per Department Incharge 561 Supplying of Headphone with built in microphoneas per Department Incharge 562 Supplying of Printer with scanner (Laser,Colour/B/W)as per Department Incharge 563 Supplying of Scanner(USB,25.2D x 36.8W x 4.3H Centimeters,Slide) as per Department Incharge 564 Supplying of Xerox Machine:- (,Platen cover & Toner, Resolution (DPI):1200 X 1200dpi, Duty Cycle:1.3 Sec) as per Department Incharge 565 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-500mm,Laminating speed-1200mm)as per Department Incharge 566 Supplying of CCTV Camera(Full HD Picture,AI Powered Motion Detection,Infrared Night Vision; 360° Panorama,Talk Back Feature (2-Way Audio)Material Type: Plastic; Included Components: Camera, Power Adapter, Charging Cable, Wall Mounting Kit, User Manual; Specific Uses For Product: Surveillance) as per Department Incharge 567 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 568 Supplying of RS75+ TT7519RS RS 75+ comes with 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Android Model Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management. as per Department Incharge 569 Supplying of Wall Mount Kit(Material: SS,Max loading capacity-60 to 100kg) as per Department Incharge 570 Supplying of Live streaming software Software Software for Live Streaming or Live telecast as per Department Incharge 571 Supplying of 75 inch diagonal length with 3 GB RAM, 48 GB ROM 4K Display, Slim Frame, Anti-Glare Glass, 3M Anti-Glare, H7 touch surface hardness, Light weight for easy installation. Media Suits for Annotation Software. Bundle with Education Apps. Office Suits. Great Writing Experience. Object Recognition- Fist/Palm/Fine Pen, Touch Points-20 points under Android. 178 Degree viewing Angle, IR Touch. 15000:1 contrast ratio, 4MS Response Time, 50000 Hours life. Reduce cluster and bring efficiency for the faculty. Remote control, 15 watts x 2 speaker. Android 8.0 Newline Cast Display Management including wall mount and installation. as per Department Incharge 572 Supplying of Frieght Transportation of 4K Display,Wall mount kit,Live Streaming software as per Department Incharge 573 Supplying of cctv solutions for Department with 20 cameras(Image Sensor Type-CMOS,Image Sensor Size-0.357 inch,Camera Image Sensing capacity (Picture Mode)-2MP,Resolution-Full HD (1920 x 1080 Pixel)-Day/Night Capable-Yes,IR illumination Range(mtr) 200 Type of Camera HousingDOME CAMERA,IP Camera Yes) as per Department Incharge 574 Supplying of installation and commisioning of CCTV and other computer equipment as per Department Incharge 575 Supplying of 55 Tv for seeing all cctv in HOD room as per Department Incharge 576 Supplying of8 PORT EPBX as per Department Incharge 577 Supplying ofTELEPHONE as per Department Incharge 578 Supplying ofWIRE as per Department Incharge 579 Supplying of CRON BOX as per Department Incharge 580 Supplying ofSWITCHES FOR PORTS as per Department Incharge 581 Supplying of Workststion Table, Chairs, Desktop, UPS as per Department Incharge 582 Supplying of LAN, Switches, Necessary Cabling, Casing Power Supply Port including Cables as per Department Incharge 583 Supplying of Refrigerator(Storage & Interior Description : | Cooling Type ; Frost Free | Display Type ; Thermostat | Shelf Material ; Toughened Glass | Compressor Type ; Reciprocatory)as per Department Incharge 584 Supplying of Microwave(Special Features: Quartz Heater - Concealed Heating. Safer Cooking, Stainless Steel Cavity - More Hygienic. More Durable, Child Lock - Ensures complete safety especially for homes with young children, Interior light)as per Department Incharge 585 Supplying of Washing Machine( Fully automatic 6 kg) as per Department Incharge 586 Supplying of Sewing Machine(Motorised)as per Department Incharge 587 Supplying of Weighting Machineas per Department Incharge 588 Supplying of Blood Pressure Monitor as per Department Incharge 589 Supplying of Oximeter as per Department Incharge 590 Supplying of Gluco Meter as per Department Incharge 591 Supplying of Test Tube & Breakers as per Department Incharge 592 Supplying of RO Water Purifier as per Department Incharge 593 Supplying of Microscope(Student) as per Department Incharge 594 Supplying of Crockery Set as per Department Incharge 595 Supplying of Cocking Utensils set as per Department Incharge 596 Supplying of Cutlery Set as per Department Incharge 597 Supplying of Sofa Set + Centre Table as per Department Incharge 598 Supplying of A.C (Split 2 Ton,3 Star,Twin invertor HD Compressor)as per Department Incharge 599 Supplying of Stabilizer(Automatic Voltage Stabilizer,37.4 x 27.1 x 19.8 Centimeters,5 kg 700 g)as per Department Incharge 600 Supplying of Inveter with battery(Capacity -100AH,Battery Type-Tubular Battery,Warranty-1 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 1 FAN ,28 Light , 8 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 601 Supplying of Desktop Computer with UPS and Computer Tableas per Department Incharge 602 Supplying of Original operating system software window 10 with Antivirus as per Department Incharge 603 Supplying of Printer with scanner (inkjet,Colour/B/W)as per Department Incharge 604 Supplying of Dining Table Set as per Department Incharge 605 Supplying of Camera as per Department Incharge 606 Supplying of Mixer Grinder as per Department Incharge 607 Supplying of Iron as per Department Incharge 608 Supplying of Wall Clockas per Department Incharge 609 Supplying of Whole tailoring Equipments (Local) as per Department Incharge 610 Supplying of Knitting Equipments(Local) as per Department Incharge 611 Supplying of Flower Arrangement Equipments) (local) as per Department Incharge 612 Supplying of Aluminium Set as per Department Incharge 613 Supplying of Plastic Tub as per Department Incharge 614 Supplying of Dustbin(Big) as per Department Incharge 615 Supplying of Basket &Mug as per Department Incharge 616 Supplying of White Table Cloth(Big size)as per Department Incharge 617 Supplying of Wash Basin(Local)as per Department Incharge 618 Supplying of Gas Stove +Cylinderas per Department Incharge 619 Supplying of Curtains(Local) as per Department Incharge 620 Supplying of Floor Mats (Local) as per Department Incharge 621 Supplying of Tube Lightas per Department Incharge 622 Supplying of Fan as per Department Incharge 623 Supplying of Led Projector(New Edition)as per Department Incharge 624 Supplying of Smart Board(specification:white,power consumption<150w ,usage-school,Effective touch-65x46) as per Department Incharge 625 Supplying of Decorative Items(Local) as per Department Incharge 626 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 60 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 15000 ppm,Features-Two-sided printing,Weight-25kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scanner multi as per Department Incharge 627 Supplying of Ceiling Fanas per Department Incharge 628 Supplying of Exhaust Fan as per Department Incharge 629 Supplying of Pedestal Fan as per Department Incharge 630 Supplying of Inveter with battery(Capacity -200AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 14 Hrs Backup- 4 FAN , 8 Light , 14 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 631 Supplying of Wooden Stool(Local) as per Department Incharge 632 Supplying of Wash Basin (Local) as per Department Incharge 633 Supplying of Register (Local) as per Department Incharge 634 Supplying of Stabilizer for ACas per Department Incharge 635 Supplying of Tubelightas per Department Incharge 636 Supplying of Dustbin (Local) as per Department Incharge 637 Supplying of Curtains (Window and Door) (Local)as per Department Incharge 638 Supplying of Door Mat(Local) as per Department Incharge 639 Supplying of Broadband(Wifi)as per Department Incharge 640 Supplying of Furniture Bookshelves, Study Tables and Chairs for attendant and students (30 students at a time) as per Department Incharge 641 Supplying of Wireless mic as per Department Incharge 642 Supplying of Weight Box(100g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 643 Supplying of Weight Box(50g std.) :- Containing 10 cynlinders of the same size and shape but different in weight as per Department Incharge 644 Supplying of Kymograph :-with smoked paper, smoked Drum, Time marker as per Department Incharge 645 Supplying of Memory Drum :- Electrical operated as per Department Incharge 646 Supplying of Memory Drum :- Hand operated as per Department Incharge 647 Supplying of Metronome :- Mechanical as per Department Incharge 648 Supplying of Porteuz Maze Test as per Department Incharge 649 Supplying of Techisto-scope :- Fall Drop type as per Department Incharge 650 Supplying of Techisto-scope :-Electronic as per Department Incharge 651 Supplying of Verniers chronoscope :- Pendulum Type as per Department Incharge 652 Supplying of Ergograph/Smoke drum /smoke paper varshing tray and varnish :- Hand grip model as per Department Incharge 653 Supplying of Weight 6Kg as per Department Incharge 654 Supplying of Multiplication sheets(100sheet) as per Department Incharge 655 Supplying of Screen:- Wooden as per Department Incharge 656 Supplying of Ravens Progressive Matrices as per Department Incharge 657 Supplying of Weschlers Intelligence scale (Adult) as per Department Incharge 658 Supplying of Cattles 16 PF Questionnaire as per Department Incharge 659 Supplying of Jungs Word Association Test as per Department Incharge 660 Supplying of Thematics Apperception Test as per Department Incharge 661 Supplying of Zeigarnik Effect Test as per Department Incharge 662 Supplying of The Occupational Stress Index(OSI) Scale by A.K Shrivastawa and A.P. Singh as per Department Incharge 663 Supplying of Rorschach Test as per Department Incharge 664 Supplying of Coping Strategies Test by A.K. Shrivastava as per Department Incharge 665 Supplying of Job Satisfaction scale(JSS) by Amar Singh and T.R. Sharma as per Department Incharge 666 Supplying of Job Involvement Scale by A.K. Singh and R. Kapoor as per Department Incharge. 667 Supplying ofOrganizational Climate Scale by Somnath Chatopadhya and K.G. Agarwal as per Department Incharge 668 Supplying of Managerial Aptitude Scale(MAS) by Santosh Dhar, Upinder Dhar and Priyanka Sharma as per Department Incharge 669 Supplying of Employees Motivational Scale by A.K. Shrivastava as per Department Incharge 670 Supplying of Employees Mental Health Inventory (EMHI) by Jagdish as per Department Incharge 671 Supplying of Beck Depression Inventory by Arron Beck as per Department Incharge 672 Supplying of Aggration Scale (AS) by G.P. Mathur and Rajkumar Bhatnagar as per Department Incharge 673 Supplying of Ego Strength Scale by Q. Hassan as per Department Incharge 674 Supplying of Bells Adjustment Iventory by S.M. Mohsin and Shamshad as per Department Incharge 675 Supplying of Marital Adjustment Questionnaire by P. Kumar and kanchan Rohtagi as per Department Incharge 676 Supplying of Sacks Sentence Completion Test as per Department Incharge 677 Supplying of PGI Health Questionnaire N-1 (PGIHQN) by S.K. Verma, N.N. Wig and D. Prasad as per Department Incharge 678 Supplying of Rotters Locus of Control Scal by Anand Kumar and S.N Srivastava as per Department Incharge 679 Supplying of Self Concept Inventory by O.N Srivastava as per Department Incharge 680 Supplying of PGI Social Support Scale by S.K. Verma, P. Kulhara and Ritu Nehraas per Department Incharge 681 Supplying of Emotiobnal Maturity Scale(EMS) by R.R. Trtipathi as per Department Incharge 682 Supplying of Life satisfaction Scale(LSS) by Q.G. Alam and R. Srivastava as per Department Incharge 683 Supplying of PGI Quality of Life Scale by S.K Verma and A.C. Moudgil as per Department Incharge 684 Supplying of Environmental Awareness Scale (EAS) by Haseen Taj as per Department Incharge 685 Supplying of Jatota Test of Group Mental ability as per Department Incharge 686 Supplying of Weinsteins Noise Sensitivy Scale (WNSS)(Shore Samvedi Mapak) by P. Bhatia, S. Mohar and I.S Mohar as per Department Incharge 687 Supplying of State Traight Anxiety Test (STAT) as per Department Incharge 688 Supplying of Xerox Machines (Digital)(Product Specification:Copy | Print | Scan | Fax,Number Of Trays-2,Item Color-Black,Duty Cycle-20000,Print Technology-LaserPrint Speed-25 Paper Per Minute ) as per Department Incharge 689 Supplying of Binding Machine (Product Specification:Capacity-12-15 Sheets,Binding Style-Manual ,Max Binding Thickness<20 mm Max Binding Sheet Width 200-300 mm,Automatic Grade-Semi-Automatic,Weight-5.8Kgs Approx.,Dimension-375x230x150mm Approx.Automation Grade,Hole Size-3x8mm,Paper Size-A4 /Letter /A5 etc,Packaging Weight-375 mm,Handle Type-metal,Packaging Size-375x230x150mm Approx.Adjustable Margin-2.5/4.5/6.5mm,Usage/Application-Comb Binding Method Of Operation-Manual,No Of Punch Holes-21 holes Number Of Punch Slots-21 holes,Size-A4,Number Of Punch Holes-21 holes,Machine Dimension-375x230x150mm Approx.Is It Padded)as per Department Incharge 690 Supplying of Printers(Ink End Sensor-yes,paper storage capacity-100 sheets Paper Input, 50 sheets Paper Output-printing technology ink tank,connecter type-Wi-Fi, USB,special feature-Cost per print - 9 paise (Black & White), 33 paise (Colour) as per Department Incharge 691 Supplying of Furnishing (Book shelves:Study table and chair)as per Department Incharge 692 Supplying of Book Case(for Psychological Tests) as per Department Incharge 693 Supplying of Open Racks as per Department Incharge 694 Supplying of Inveter with battery(Capacity -150AH,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit, Over Temperature, Battery Deep -Discharge,Backup Time 8 Hrs Backup- 2 FAN , 2 Light , 12 Hrs Backup - 1FAN ,1 Light Battery Condition-New) as per Department Incharge 695 Supplying of Inverter with Battery(Capacity-150,Battery Type-Tubular Battery,Warranty-3 years,Protection From Short Circuit Backup Time-5hrs,Battery Condition-New)as per Department Incharge 696 Supplying of Desktop(Product Specification:Hard Drive Capacity-320GB,Operating System-Window,Screen Size-17 inch Processor-i5,Display Type LCD Processor) as per Department Incharge 697 Supplying of Tally sofware (Multi User) as per Department Incharge 698 Supplying of Barcode Machine(Product Specification:Type-Thermal Printers,Max Printing Size-10 IPS,Resolution (dpi)-203dpi Model/Type-Citizen CLS-700,Automatic Grade-Fully Automatic Print Line-1~3 Lines) as per Department Incharge 699 Supplying of Server Machines(Product Specification:Memory-1x16 GB RAM/ Open Bay- 2.5 Hot Swap SAS/ SATA,Power Supply 220 V,Networking Type-LAN,Number Of Ports/Channels-8 USB Port-Yes Processor Speed Intel Xeon Silver 4114 (Deca Core) 2.2GHz Power Consumption 750 W) as per Department Incharge 700 Supplying of LAN connection between 7 computers as per Department Incharge 701 Supplying of Xerox Machine (Specification-Functions:Print | Scan | Copy,Technology -Laser,Print speed-upto 30 pages/min,Paper size-A4,Connectivity-Wireless(Wi-Fi),Color output-Color | B&W, Print Volume(per month) -above 10000 ppm,Features-Two-sided printing,Weight-16.8kg,Dimension-451 x 460 x 360mm,Scanner type Flatbed scannercannon image Class MF641CW multi as per Department Incharge 702 Supplying of Lamination Machine(Paper size-A4,A3,FS,max laminating width-330mm,Laminating speed-600mm)as per Department Incharge 703 Supplying of Binding Machine (Punches-43 holes,Hole distance-43 holes in A 11 SHEET,Binding sizes:Max 11) as per Department Incharge 704 Supplying of Computers (Processor -AMD Ryzen 3,RAM-8GB,HDD-512 GB,screen size-19.5 inches,Operating system:Windows 11 )as per Department Incharge 705 Supplying of Office Computer (Processor:i5 10th,HDD:1 TB,RAM-4 GB,GT730 4GB Graphics) as per Department Incharge 706 Supplying oflaser printer(Product Specification:Color Output-Black & White,Function-Print | Scan | Copy,Max. Print Speed (Black)-18 ppm Max. Print Speed (Color)-17 ppm,Connectivity-Ethernet,Paper Size-A4,Print Volume-Up to 500 pages/month) as per Department Incharge 707 Supplying of Smart class Board(Power consumption:220-300V,size/Dimension-65,Input type-finger Touch) per Department Incharge 708 Supplying of Double battery(capacity-250Ah,Over current protection) Inverter(Back up time-5 hrs) as per Department Incharge 709 Supplying of Desktop Computers :- HP 23.8-inch FHD All in One Desktop with Alexa Built-in(10th Gen Intel Core i3- 1005G1/8GB/512 GB SSD/Windows 10/MS Office 2019/Natural Silver), 24-dp0816in as per Department Incharge 710 Supplying of Printer, ScannerMulti-Function Direct Wireless Network Laser Printer (Print, copy, scan, Black) as per Department Incharge 711 Supplying of Networking (LAN, leased lines, wi-fi, switches etc.) TP-Link Archer C6 Gigabit MU-MIMO Wireless Router, Dual Band 1200Mbps Wi-Fi Speed, 5 Gigabit Ports, 4 External Antennas and 1 Internal Antenna WiFi Coverage with Access as per Department Incharge 712 Supplying of Back up support(UPS, Generator, Transformer):-600VA UPS for Desktop/PC/Computers(not for Routers) with Automatic Voltage Regulation as per Department Incharge 713 Supplying of Xerox Machine:- (IR2004 With Duplex, Platen cover & Toner, Resolution (DPI):600 X 600dpi, Duty Cycle:4.3 Sec) as per Department Incharge 714 Supplying of IBM SPSS(Statistics Package Latest Version) as per Department Incharge 715 Supplying of Nvovo(Package) as per Department Incharge 716 Supplying of LCD Projector:- 1)Project movies,images or data from your devices,most effective in dark settings 2)Projector, Lens Cover/Stand, Carrying Pounch, USB Cable 3) Connect via Wi-Fi to Android smartphones and tables or connect HDMI to iPhone or iPad as per Department Incharge 717 Supplying of Projector Screen:- 1)10 Feet x 6 Feet, 133 Dia, 16:9 Format, UHD-3D-4K 2)Comes with FULL HD 1080P 3D and 4K Viewing Technology, Anti UV coating as per Department Incharge 718 Supplying of DTH connection:- 1)HD Set Top Box 2)Recording facility as per Department Incharge 719 Supplying of Television Set:- 1) Smart LED TV-42 inches 2)4K UHD (Resolution:3840x2160) 3)Connectivity-Input:3*HDMI,3*USB 4)Audio:20W output 5) 4K HDR provides exceptional clarity 6)Smartphone connectivity : Photo sharing plus, screen mirroring as per Department Incharge 720 Supplying of as per Desktop:- Intel i7, 8th Gen, 4GB N-Vidia Geforce Graphics card, 16 GB RAM, Monitor, CPU, Mouse, key board partment Incharge 721 Supplying of Multifunction Laser Printer,Scanner, and Copier :- Functionality: Print, Scan,Copy Print Technology : Monochrome Laser Connectivity: Hi-speed USB, Compatible with USB 2.0 Specifications4as per Department Incharge 722 Supplying of Speaker 7.1 surround stereo(Power -100W,Play tme-11 hours,Voice Range-9m) as per Department Incharge 723 Supplying of Digital SLR Camera: 1)EOS full HD movie mode with movie service 2)18 megapixel CMOS)APS-(sensor 3)14-bit A/D conversion 4)ISO 100-12800)EXPANDABLE TO h:25600(5)Dual Lens camera 55-250mm IS II lens 6) Camera battery charger and bag 7)Wide strap USB cable, software CD. as per Department Incharge 724 Supplying of 24.2MP DigitalSLR Camera:- 1)100% Viewfinder Coverage 2)CMOS sensor with impressive high-resolution result 3)Camera battery, charger, and bag 4)Wide strap USB cable, software CD, manual as per Department Incharge 725 Supplying of Quark express as per Department Incharge 726 Supplying of Adobe Suite(CS6 Master Collection) as per Department Incharge 727 Supplying of Cool Edit Pro as per Department Incharge 728 Supplying of Turnitin as per Department Incharge 729 Supplying of Sound Forge as per Department Incharge 730 Supplying of 18-55mm normal lens as per Department Incharge 731 Supplying of 55-250mm Zoom lens as per Department Incharge 732 Supplying of 18-135mm lens as per Department Incharge 733 Supplying of 35mm prime lens as per Department Incharge 734 Supplying of 80mm macro lensas per Department Incharge 735 Supplying of Tripods as per Department Incharge 736 Supplying of DSLR:- 1)Powered by NP-F570 InfoLithium rechargeble battery pack 2)Records to MiniDV tape stock 3)16:9 widescreen recording 4)3CCD video camera 5)12x optical zoom lens 6)Records to MiniDV tape stock as per Department Incharge 737 Supplying of:- 1)3CCD video camera 2) Crystal Engine 3)Shoulder -Type Design 3)One Touch Navigation 4)Manual Focus Ring 5) 0 lux colour light view 6)10x optical zoom 6)500x digital zoom 7)Super image stabilizer 8) DV IN/OUT Terminal 8)5-mode programme AE: sports, portrait, low light, spot light, and surf &snow 9)SP/I.P recording 10)Back light compensation 11) Cinema mode )16:9 aspect ratio( 12)Infra-red remote controller as per Department Incharge 738 Supplying of Tripods:- 1)3-way head with adjustable pan 2)Steady rubberized legs 3)Multipurpose head with quick release 4)Multipupose head for DV cameras 5)Made from High Grade Aliminium Alloy 6)Quik flip leg locks 7)Fluid pan&tilt movement 8)Quik release plate& Bubble Level as per Department Incharge 739 Supplying of i-Mac(Product Specification,Storage Capacity-256 GB Display-24 inch,Memory Size-256gb ssd,assembled Product Dimensions L X W X H,461 mm x 547 mm x 130 mm, 4.48 kg Color-Silver & Blue,Graphics-8_core GPU,Video Support And Camera 4.5K,Bluetooth-Bluetooth 5.0,Weight-4.48kg,Operating System-macOS Big Sur,Processor- M1Echip,Line Voltage-100-240V AC) for Video Editing as per Department Incharge 740 Supplying of Photographic Design Flash Bender-Small Reflector:- 1) Make a bounce flash reflector, gobo, or snoot 2)Packs flat/great for travel 3)Attaches quickly & securely 4)Adjustable to fit all popular brands of accessory flash 5)For on-camera or off-camera flash as per Department Incharge 741 Supplying of Rim Collapsible softbox Diffuser with Rim :-1)Softbox 36 inches/90 Centimeters with Grey Rim and Bowens Mount, Portable and Quick Folding Softbox Diffuser for Photography Speedlites Flash Monolight 2)for 660 LED Panel-Outer 16.3x6.5 inches,Inner 9.8x8.7 inches Collapsible Light Reflector 3)with Stap Attachment and Carrying Bag for Photo Studio Portrait Video Shooting as per Department Incharge 742 Supplying of Handheld Camera Stabilizer with Quik Release for DSLR:- 1)Light weight, handheld video image stabilization 2)FlyCam 3000 video cam stabilizer accepts camera upto 3.5kg/7.7Ibs. 3)Easy attach a small LCD monitor with Flycam 3000 cam stabilizer when needed. 4)Precision Aluminum made 5)23 tall and just 207 Ibs without counter balance disc. as per Department Incharge 743 Supplying of Green/Blue matte screen )Chroma key( :- 1)8x12 ft Blackboard, perfect for television, video production and digital photography. 2)Rod pocket on each top edge allows to be draped or hung. 3)Finishing along all edges to prevent tears. 4)Made of 100 %pure cotton, good vertical sense and durable as per Department Incharge 744 Supplying of Professional Grade Backdrop Cum Light Stand of 8 Feet Height:- 1)Photography Backdrop Stand Kit. 2)Stand of 8 Feet Height 3)8x12 ft Blackboard, perfect for television, video production and digital photography. 4) Package Contents; 1Pcs White Backdrop , 1Pcs Black Backdrop and Set of Black Backdrop stand. 5)Bag to carry as per Department Incharge 745 Supplying of Video Mixer (Four Channel Digital Video Mixer With Effects, including installation and training):- 1) four channel video mixer by incorportating HDMI inputs/outputs, USB streaming, HDCP support, built-in touch multi-viewer, and audio embedding . 2)(3Input)SD HDMI/Composite +(1Input) Up to1080p HDMI/RGB/Component/Composite. 3) PGM Output) Up to 1080p HDMI + RGB/Component +Composite +(PVW Output)PVW/Multiviewer(. 4)480p/576p Progressive internal processing 5.) Built-in multi-viewer ith touch control 6). Built-in frame synchronizers on all inputs 7). Scalers on CH 4 and Output 8). 259 Transitions 148 Effects 9). HDCP Compliant 10) Audio Embedding 11) Audio Mixer & Delay -up to 4 Fframes 12) USB Streaming Out for web-streaming 13) Video Processing:4:2:2 )Y/b/Pr(8 bits)Internal Processing :480/59.94p when set to NTSC, 576/50p when set to PAL( 14) Input Formats :HDMIVideo: INPUT 1 to3 : reqyires 720x480/59.94p )when set to NTSC( 576/50p ) When set to PAL(15) Input Formats : HDMI and Component Video : INPUT 4:480/59.94p, 720/59.94p, 1080/59.94i, 1080/59.94p )when set to NTSC (576/50i, 576/50p, 720/50p, 1080/50i, 1080/50p )when set PAL( as per Department Incharge 746 Supplying of Studio Condenser Microphone :- 1)Professional, large-diaphragm condenser microphone for unsurpassed audio quality 2) Idea as Mian and support microphone for studio and live applications. 3) Cardioid pickup pattern for outstanding sound source separation and feedback rejection 4)Pressure-gradient transducer with shock-mounted capsule. 5)Ultra-low noise, transformerless FET inputeliminates low-frequency distortion. 6) LED indicates phantom power operation. 7)Swivel stand mount and transport case included. 8)Ultra-rugged construction with metal die-cast body 8)Gold-plated 3-pin XLR output connector for highest signal integrityas per Department Incharge 747 Supplying of Digital Monitor/Speaker System(in Pair) :- 1)Two-way active monitor system for multimedia workstations and keyboard monitoring 2)High-power woofers and tweeters powered provided a linear frequency response 3)optical and coaxial inputs to directly connect digital audio sources via S/PDIF interface 4)Two stereo analogue inputs featuring 1/8 TRS and stereo RCA connectors can be used simultaneously or mixed with a digital stereo source 5)Features 1/4 TRS headphone connector with auto-mute function easily accessible from the front panel 6)2x Stereo Anaog Inputs )TRS and Stereo RCA Connectors( 7) 1/4-inch TRS headphone connector with Auto-mute Loudspeaker Function 8)1/8-inch TRS and Stereo RCA connectors as per Department Incharge 748 Supplying of Lapel Clip-on Microphone for DSLRs Camcorders Video Cameras and Iphone Smart Phone :- 1)Omni directional lavalier microphone, designed for Smartphones, DSLR, Camcorders, Audio recorders PC etc, perfect for video use. 2) With Omni pickup pattern, for full 360A coverage, 3) minimum 6-meter )20(cable with 3.5mm 4-pole gold plug for smarty phone connection as per Department Incharge 749 Supplying of Micophone Stand:- Steel stands for hand held microphones in studio with a base supporting system as per Department Incharge 750 Supplying of MP3 Digital Voice IC Recorder LCD :- 1)Digital Voice IC Recorder 2)LCD Screen 3) 23hrs life with 4GB Memory as per Department Incharge
Contract Date: Jun 17, 2026 Contract Value : 78.07 Crore
Government Departments No of Bidders 9
14.
Power #10172978 AOC
Tender For Annual Maintenance Repair Of Md Dvvnl Office Vidyut Adhikari Colony At 220 Kv Sub Station, Sikandra, Agra - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR )(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. (DSR )(DSR 2.27) 8 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 9 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (DSR 2.29) All kinds of soil (DSR 2.29.1) 10 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 11 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 12 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.32) 13 Supplying chemical emulsion in sealed containers including delivery as specified. (DSR 2.34) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (DSR 2.34.1) 14 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.1.1) 15 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.2.1) 16 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1) 17 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 2.35.4 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.4.1) 18 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (DSR 2.35.5) 19 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. (DSR )(DSR 2.36) 20 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 21 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 22 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 23 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.11) 24 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 25 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 26 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III)including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)). (DSR 4.2.3A) 27 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR 4.2.8) 28 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 29 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (DSR 4.3.2) 30 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Columns, piers, abutments, pillars, posts and struts (DSR 4.3.3) 31 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.4.1) 32 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. (DSR 4.5) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) (DSR 4.5.1) 33 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (DSR 4.6) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.6.1) 34 Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : (DSR 4.7) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.7.1) 35 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. (DSR )(DSR 4.9) 36 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).(DSR )(DSR 4.11) 37 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 38 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) C (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 39 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 40 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 41 Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.4) 42 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.5) 43 Reinforced cement concrete work in chimneys, shafts, up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.6) 44 Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). (DSR )(DSR 5.8) 45 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) 46 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) 47 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 48 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 49 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 50 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 51 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 52 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Chimneys and shafts (DSR 5.9.11) 53 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards(DSR 5.9.13) 54 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 55 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 56 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 57 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 58 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 59 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 60 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6) 61 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR 5.22A) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A.6) 62 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 63 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 64 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 65 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 66 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 67 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 68 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 69 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab upto 0.50 sqm (DSR 8.2.2.1) 70 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab over 0.50 sqm (DSR 8.2.2.2) 71 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of all colour and texture except black, Cherry/Ruby red 8.2.3 Area of slab over 0.50 sqm (DSR 8.2.3.2) 72 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 73 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 74 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 75 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 76 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 77 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 78 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 79 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 80 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 81 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (DSR )(DSR 8.32) 82 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 83 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 84 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 85 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 86 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 87 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 88 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 89 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 90 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 91 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 92 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 93 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 94 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 95 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 18 mm thick (DSR 9.18.1) 96 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 25 mm thick (DSR 9.18.2) 97 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1) 98 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.2) 99 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws (DSR 9.20.3) 100 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) 101 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 102 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.21.3) 103 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). (DSR 9.25) Decorative type door (DSR 9.25.1) 104 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). (DSR )(DSR 9.26) 105 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.1.1 Second class teak wood (DSR 9.27.1.1.1 ) 106 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) With ISI marked stainless steel butt hinges of required size 9.27.1.2 Second class teak wood (DSR 9.27.1.2.1) 107 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.2.1 Second class teak wood (DSR 9.27.2.1.1) 108 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) With ISI marked stainless steel butt hinges of required size 9.27.2.2 Second class teak wood (DSR 9.27.2.2.1) 109 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50x12 mm (DSR 9.40.1.1) 110 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50 x 20 mm (DSR 9.40.1.2) 111 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 112 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x20 mm (DSR 9.40.2.2) 113 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 20 mm dia (heavy type) (DSR 9.47.1) 114 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 115 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 116 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to openings /wooden frames with rawl plugs screws etc. (DSR 9.48.2) 117 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 125x90x4.00 mm (DSR 9.56.1) 118 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 100x75x3.50 mm (DSR 9.56.2) 119 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 75x60x3.10 mm (DSR 9.56.3) 120 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 121 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 122 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 123 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 150 mm (DSR 9.59.1) 124 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 125 mm (DSR 9.59.2) 125 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 100 mm (DSR 9.59.3) 126 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 150 mm (DSR 9.60.1) 127 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 125 mm (DSR 9.60.2) 128 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 100 mm (DSR 9.60.3) 129 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 300x16 mm (DSR 9.62.1) 130 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 131 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 250x10 mm (DSR 9.63.1) 132 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 133 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 134 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 100x10 mm (DSR 9.63.4) 135 Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). (DSR )(DSR 9.64) 136 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 300x20x6 mm (DSR 9.65.1) 137 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 250x20x6 mm (DSR 9.65.2) 138 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 139 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 140 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 141 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 150 mm (DSR 9.67.1) 142 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 115 mm (DSR 9.67.2) 143 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 90 mm (DSR 9.67.3) 144 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 125x64x1.90 mm (DSR 9.70.1) 145 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 100X58X1.90 mm (DSR 9.70.2) 146 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 75x47x1.80 mm (DSR 9.70.3) 147 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 50x37x1.50 mm (DSR 9.70.4) 148 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 125x64x2.50 mm (DSR 9.71.1) 149 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 100x60x2.50 mm (DSR 9.71.2) 150 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 75x50x2.50 mm (DSR 9.71.3) 151 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 250x10 mm (DSR 9.74.1) 152 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 200x10 mm (DSR 9.74.2) 153 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 150x10 mm (DSR 9.74.3) 154 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 100x10 mm (DSR 9.74.4) 155 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.76) 156 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.77) 157 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR )(DSR 9.83) 158 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR )(DSR 9.84) 159 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 150 mm (DSR 9.87.1) 160 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 115 mm (DSR 9.87.2) 161 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 90 mm (DSR 9.87.3) 162 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.88) 163 Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (DSR )(DSR 9.89) 164 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 40 mm (DSR 9.90.1) 165 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 50 mm (DSR 9.90.2) 166 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 65 mm (DSR 9.90.3) 167 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 75 mm (DSR 9.90.4) 168 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. (DSR )(DSR 9.91) 169 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 125 mm (DSR 9.92.1) 170 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 100 mm (DSR 9.92.2) 171 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 75 mm (DSR 9.92.3) 172 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. (DSR )(DSR 9.93) 173 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 125x63x4 mm (DSR 9.95.2) 174 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 100x63x3.2 mm (DSR 9.95.5) 175 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 75x63x3.2 mm (DSR 9.95.7) 176 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 300x16 mm (DSR 9.96.1) 177 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 250x16 mm (DSR 9.96.2) 178 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 300x10 mm (DSR 9.97.1) 179 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 250x10 mm (DSR 9.97.2) 180 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 200x10 mm (DSR 9.97.3) 181 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 150x10 mm (DSR 9.97.4) 182 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 100x10 mm (DSR 9.97.5) 183 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. (DSR )(DSR 9.98) 184 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (DSR )(DSR 9.99) 185 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 125 mm (DSR 9.100.1) 186 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 100 mm (DSR 9.100.2) 187 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 75 mm (DSR 9.100.3) 188 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Single rubber stopper (DSR 9.101.1) 189 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Twin rubber stopper (DSR 9.101.2) 190 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.103) 191 Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod. (DSR )(DSR 9.104) 192 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. (DSR )(DSR 9.110) 193 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Triple strip vertical type (DSR 9.114.1) 194 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Double strip (horizontal type) (DSR 9.114.2) 195 Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.115) 196 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) (DSR )(DSR 9.116) 197 Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. (DSR 9.126) Marine plywood conforming to IS: 710 (DSR 9.126.1) 198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.5 mm thick (DSR 9.127.1) 199 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.0 mm thick (DSR 9.127.2) 200 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge (DSR )(DSR 9.129) 201 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :30 mm thick shutters (DSR 9.134.2) With ISI marked stainless steel butt hinges of required size 9.134.2.2 Second class teak wood (DSR 9.134.2.2.1 ) 202 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. (DSR 9.135) With 2nd class teak wood beading 62X19 mm (DSR 9.135.1) 203 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 125 mm (DSR 9.165.1) 204 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 100mm (DSR 9.165.2) 205 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 75 mm (DSR 9.165.3) 206 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). (DSR 9.166) 18 mm thick (DSR 9.166.1) 207 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 9.167) 208 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)(DSR )(DSR 9.168) 209 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge.(DSR )(DSR 9.169) 210 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. (DSR 9.17) 200 mm (DSR 9.170.1) 211 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 9.171) 212 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.172) 213 Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensilbasket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) (DSR )(DSR 9.173) 214 Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.174) 215 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 216 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.2) 217 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.10.1) 218 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.10.2) 219 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.15.1) 220 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 222 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 223 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 224 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (DSR 10.25.1) 225 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 226 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) M.S. tube (DSR 10.26.1) 227 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) E.R.W. tubes (DSR 10.26.2) 228 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 229 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 230 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 231 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR )(DSR 10.31) 232 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:4 (1 cement : 4 coarse sand) (DSR 11.1.1) 233 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:6 (1cement : 6 coarse sand) (DSR 11.1.2) 234 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 235 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 236 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6) 18 mm thick (DSR 11.6.1) 237 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (DSR )(DSR 11.7) 238 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (DSR ) 40 mm wide and 4 mm thick (DSR 11.13.1) 239 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Dark shade pigment using ordinary cement (DSR 11.20.3) 240 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Ordinary cement without any pigment (DSR 11.20.4) 241 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1 Acid and alkali resistant tile (DSR 11.21.1.1) 242 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2 Acid and alkali resistant tile (DSR 11.21.2.1) 243 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23) Udaipur green marble (DSR 11.23.5) 244 Extra for pre finished nosing to treads of steps of marble stone. (DSR )(DSR 11.24) 245 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (DSR )(DSR 11.25) 246 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 247 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 248 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. (DSR 11.28) Red sand stone (DSR 11.28.1) 249 Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR )(DSR 11.32) 250 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 251 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 11.37A) 252 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. (DSR )(DSR 11.38) 253 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 254 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A) Double charge vitrified tile polished finish of size 11.41A.1 Size of Tile 600 x 600 mm (DSR 11.41A.1.1) 255 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 11.45) 256 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 257 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400mm of all colours and shades.(DSR )(DSR 11.49A) 258 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR )(DSR 11.50) 259 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 260 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 261 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (DSR 12.45) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (DSR 12.45.1) 262 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (DSR 12.47) 2 mm thick flat (DSR 12.47.2) 263 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.52) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. (DSR 12.52.4) 264 Providing and fixing tiled false ceiling of specifiedmaterials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.58) 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. (DSR 12.58.1) 265 Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufactures specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: (DSR 12.59) 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. (DSR 12.59.1) 266 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 267 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Ridges plain (500- 600mm) (DSR 12.66.1) 268 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Crimp curve (DSR 12.66.5) 269 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Gutter (600 mm over all girth) (DSR 12.66.6) 270 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 271 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 272 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 273 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 274 Neat cement punning. (DSR )(DSR 13.18) 275 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 276 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 277 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 278 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (DSR 13.47) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.47.1) 279 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (DSR 13.48.1) 280 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 13.48.2) 281 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 13.48.3) 282 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. (DSR 13.48A) New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A.1) 283 Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. (DSR )(DSR 13.59) 284 Lettering with black Japan paint of approved brand and manufacture (DSR )(DSR 13.71) 285 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 286 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 287 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) One coat (DSR 13.82.1) 288 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) Two coats (DSR 13.82.2) 289 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) One coat (DSR 13.83.1) 290 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) Two coats (DSR 13.83.2) 291 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (DSR 13.85.1) 292 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3) 293 White washing with lime to give an even shade : (DSR 13.87) Old work (two or more coats) (DSR 13.87.1) 294 White washing with lime to give an even shade : (DSR 13.87) Old work (one or more coats) (DSR 13.87.2) 295 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 296 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 297 Painting with oil type wood preservative of approved brand and manufacture: (DSR 13.97) Old work (one or more coats) (DSR 13.97.1) 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 299 Re-lettering with black Japan paint of approved brand and manufacture. (DSR )(DSR 13.105) 300 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. (DSR )(DSR 13.106) 301 Finishing walls with textured exterior paint of required shade : (DSR 13.11) Old work (One or more coats) applied @ 1.82 ltr/10 sqm. (DSR 13.110.2) 302 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 303 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 304 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1) 305 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (DSR 13.112.2) 306 Varnishing with varnish of approved brand and manufacture: (DSR 13.113) One or more coats with copal varnish (DSR 13.113.1) 307 Melamine polishing on wood work (one or more coat). (DSR )(DSR 13.114) 308 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (DSR )(DSR 13.116) 309 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Door chowkhats (DSR 14.2.1) 310 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Window chowkhats (DSR 14.2.2) 311 Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. (DSR )(DSR 14.3) 312 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.4) For door/ window/ clerestory window (DSR 14.4.1) 313 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 314 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.5.2) 315 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.7.1) 316 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.7.2) 317 Supplying and fixing new wooden fillets wherever necessary: (DSR 14.8) Hollock wood fillets (DSR 14.8.2) 318 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 319 Refixing old glass panes with putty and nails (DSR )(DSR 14.10) 320 Fixing old glass panes with wooden fillets (excluding cost of fillets) (DSR )(DSR 14.11) 321 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. (DSR )(DSR 14.12) 322 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR )(DSR 14.17) 323 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel 50 mm dia and below (DSR 14.22.1) 324 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel above 50 mm dia (DSR 14.22.2) 325 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. (DSR )(DSR 14.23) 326 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.1) 327 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.2) 328 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.1) 329 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.2) 330 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. (DSR )(DSR 14.29) 331 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 125x70x4 mm (ordinary type) (DSR 14.40.1) 332 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 100x70x4 mm (ordinary type) (DSR 14.40.2) 333 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x65x4 mm (heavy type) (DSR 14.40.3) 334 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x40x2.5 mm (ordinary type) (DSR 14.40.4) 335 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 50x40x2.5 mm (ordinary type) (DSR 14.40.5) 336 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. (DSR )(DSR 14.41) 337 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (DSR )(DSR 14.75A) 338 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. (DSR )(DSR 14.76) 339 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm(DSR )(DSR 14.77) 340 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. (DSR )(DSR 14.78) 341 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 342 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 343 Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 14.81) 344 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 345 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. (DSR )(DSR 14.83) 346 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall (DSR )(DSR 14.84) 347 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. (DSR )(DSR 14.85) 348 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 349 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 350 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 351 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 352 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 353 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area beyond 3 sq. metres (DSR 15.12.2) 354 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area 3 sq. metres and below (DSR 15.13.1) 355 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area beyond 3 sq. metres (DSR 15.13.2) 356 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) R.S. Joists (DSR 15.17.1) 357 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) Channels, angles, tees and flats (DSR 15.17.2) 358 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR )(DSR 15.18) 359 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 360 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 361 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 362 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) Asbestos Cement sheet (DSR 15.28.2) 363 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. (DSR )(DSR 15.36) 364 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) 15 mm to 40 mm nominal bore (DSR 15.44.1) 365 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) Above 40 mm nominal bore (DSR 15.44.2) 366 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: (DSR 15.45) Up to 150 mm diameter (DSR 15.45.1) 367 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.48) 368 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.49) 369 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 370 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres (DSR 15.53) Up to 150 mm diameter (DSR 15.53.1) 371 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. (DSR )(DSR 15.54) 372 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 373 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR )(DSR 15.57) 374 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 375 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 376 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. (DSR 16.7) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.7.1) 377 Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres : (DSR 16.8) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.8.1) 378 Supplying at site : (DSR 16.15) R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately). (DSR 16.15.1) 379 Supplying at site : (DSR 16.15) Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2) 380 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. (DSR 16.17) With G.I. barbed wire (DSR 16.17.1) 381 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. (DSR 16.18) With G.I. barbed wire (DSR 16.18.1) 382 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (DSR )(DSR 16.19) 383 Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. (DSR 16.31) With medium setting bitumen emulsion 16.31.2 On bituminous surface @ 0.25kg/sqm (DSR 16.31.2.2) 384 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). (DSR 16.33) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR 16.33.1) 385 Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. (DSR )(DSR 16.40) 386 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 387 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 388 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR )(DSR 16.45) 389 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 390 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.64) 391 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.67) 392 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 393 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR )(DSR 16.69) 394 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 395 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 396 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 397 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 398 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (DSR )(DSR 16.83) 399 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). (DSR )(DSR 16.84) 400 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR )(DSR 16.89) 401 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 402 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 403 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 404 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (DSR 17.2) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1) 405 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (DSR 17.3) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.3.1) 406 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (DSR 17.7.3) 407 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4) 408 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked (DSR 17.7.9) 409 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.11) 410 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 411 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: (DSR 17.9) White glazed fire clay kitchen sink of size 600x450x 250 mm (DSR 17.9.1) 412 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink with drain board510x1040 mm bowl depth 200 mm (DSR 17.10.1.3) 413 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink without drain board 17.10.2 610x510 mm bowl depth 200 mm (DSR 17.10.2.1) 414 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. (DSR )(DSR 17.15) 415 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (DSR )(DSR 17.16A) 416 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (DSR 17.18) 10 litre capacity - White (DSR 17.18.1) 417 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : (DSR 17.2) White solid plastic seat with lid (DSR 17.20.1) 418 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR )(DSR 17.22A) 419 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia (DSR )(DSR 17.22B) 420 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (DSR )(DSR 17.23) 421 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR )(DSR 17.24) 422 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 630x450 mm (DSR 17.25.1) 423 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 424 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 450x300 mm (DSR 17.25.5) 425 Providing and fixing kitchen sink including making all connections excluding cost of fittings. (DSR 17.26) White glazed fire clay sink of size 600x450x250 mm (DSR 17.26.1) 426 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 427 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1) 428 Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR )(DSR 17.29) 429 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR )(DSR 17.30) 430 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 431 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (DSR )(DSR 17.33) 432 Providing and fixing toilet paper holder : (DSR 17.34) C.P. brass (DSR 17.34.1) 433 Providing and fixing toilet paper holder : (DSR 17.34) Vitreous china (DSR 17.34.2) 434 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 435 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms (DSR 17.69.2) 436 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms (DSR 17.70.1) 437 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms (DSR 17.70.2) 438 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR )(DSR 17.71) 439 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR )(DSR 17.72) 440 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (DSR 17.73.1) 441 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (DSR 17.73.2) 442 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (DSR )(DSR 17.74) 443 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. (DSR )(DSR 17.75) 444 Providing and fixing PTMT urinal cock of approved quality and colour. (DSR 17.76) 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms (DSR 17.76.1) 445 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. (DSR 17.77) Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) (DSR 17.77.1) 446 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR )(DSR 17.78) 447 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. (DSR )(DSR 17.79) 448 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (DSR )(DSR 17.80) 449 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (DSR )(DSR 17.81) 450 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 451 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 25 mm nominal dia Pipes (DSR 18.8.3) 452 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 15 mm nominal dia Pipes (DSR 18.9.1) 453 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2) 454 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 455 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4) 456 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 40 mm nominal dia Pipes (DSR 18.9.5) 457 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 50 mm nominal dia Pipes (DSR 18.9.6) 458 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 80 mm nominal dia Pipes (DSR 18.9.8) 459 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work (DSR 18.12) 80 mm dia nominal bore (DSR 18.12.8) 460 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 25 to 40 mm nominal bore (DSR 18.13.1) 461 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 50 to 80 mm nominal bore (DSR 18.13.2) 462 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (DSR )(DSR 18.14) 463 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 15 mm nominal bore (DSR 18.15.1) 464 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 465 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 15 mm nominal bore (DSR 18.16.1) 466 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 467 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 468 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 469 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 470 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 40 mm nominal bore (DSR 18.17.3) 471 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 80 mm nominal bore (DSR 18.17.6) 472 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Horizontal (DSR 18.19.1.1) 473 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Vertical (DSR 18.19.1.2) 474 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Horizontal (DSR 18.19.2.1) 475 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Vertical (DSR 18.19.2.2) 476 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Horizontal (DSR 18.19.3.1) 477 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Vertical (DSR 18.19.3.2) 478 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 80 mm nominal bore 18.19.6 Vertical (DSR 18.19.6.2) 479 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1) 480 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 481 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 15 mm nominal bore (DSR 18.21.2.1) 482 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 483 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 100 mm diameter (DSR 18.22.1) 484 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 150 mm diameter (DSR 18.22.2) 485 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (DSR 18.27) 100 mm dia pipe (DSR 18.27.1) 486 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : (DSR 18.28) 100 mm diameter pipe (DSR 18.28.1) 487 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 80 mm diameter pipe (DSR 18.30.1) 488 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 100 mm diameter pipe (DSR 18.30.2) 489 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class I (DSR 18.31.1.1) 490 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class II (DSR 18.31.1.2) 491 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 492 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (DSR 18.62) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms (DSR 18.62.2) 493 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (DSR )(DSR 18.63) 494 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (DSR )(DSR 18.64) 495 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 496 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. (DSR 18.84) 15 mm nominal bore (DSR 18.84.1) 497 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 498 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 150 mm dia. R.C.C. pipe (DSR 19.6.2) 499 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 300 mm dia. R.C.C. pipe (DSR 19.6.4) 500 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (DSR 19.32) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) 501 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. (DSR )(DSR 19.33) 502 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 503 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 504 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 505 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 506 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 507 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 508 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 509 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 510 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 511 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 512 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 513 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 514 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 515 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (DSR 21.8) Upto 5mm depth and 5 mm width (DSR 21.8.1) 516 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For fixed portion (DSR 21.9.1) 517 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For shutters of doors, windows & ventilators (DSR 21.9.2) 518 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). (DSR )(DSR 21.14) 519 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (DSR )(DSR 21.17) 520 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 521 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11601 (DSR 21.19) Upto 5 mm depth and 5 mm width (DSR 21.19.1) 522 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11602 (DSR 21.19) Upto 10 mm depth and 10 mm width (DSR 21.19.2) 523 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) (DSR )(DSR 22.5) 524 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck ,using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (DSR )(DSR 22.22) 525 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (DSR 23.1) All types of soil 23.1.1 300 mm dia (DSR 23.1.1.1) 526 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (DSR 23.2) All types of soil 23.2.1 350 mm dia (DSR 23.2.1.2) 527 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (DSR 23.3) 150 mm nominal size dia (DSR 23.3.2) 528 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4) 150 mm nominal size dia (DSR 23.4.2) 529 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.5) 530 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.6) 531 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (DSR )(DSR 23.7) 532 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.8) 533 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR )(DSR 23.12) 534 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: (DSR 23.13) 150 mm dia (DSR 23.13.2) 535 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. (DSR 23.14) 150 mm clamp (DSR 23.14.2) 536 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (DSR 23.15) 150 mm dia (DSR 23.15.2) 537 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (DSR )(DSR 25.1) 538 Providing and fixing factory madeKitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardenthaving necessary screw holding capacity.Shutter shall be fixed to frame usingapproved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. (DSR )(DSR 26.10) 539 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : (DSR )(DSR 26.11) 540 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 541 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 542 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 543 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 544 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 545 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 546 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 547 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 548 Supplying and fixing 63 A, four pole, 415V, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.13.2) 549 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 550 Smoke Detector with built in LED, mounting base complete with all connection etc. (DSR E&M 2022 4102) 551 Manual call boxes of MS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4103) 552 Manual call boxes of ABS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4104) 553 Response indicator on surface/recessed MS Box having two LEDs metallic covers complete with all connections etc.(DSR E&M 2022 4105) 554 Fire alarm sounders (electronic) with facility to make announcement, mounted in M.S. Box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. (DSR E&M 2022 4106) 555 Fire alarm sounders (electronic) with facility to make announcement, mounted in A,B.S. Box with hinged cover plate & suitable for operation with amplifier l/c line matching ttransformer etc. (DSR E&M 2022 4107) 556 Talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. Knob & speaker/microphone enclosed in a M.S (16 SWG)/ABS.Box, break glass in front etc. (DSR E&M 2022 4108) 557 6 Zone fire alarm control panel as per IS: 2189 with backlit LCD (DSR E&M 2022 4110) 558 Cost of25 mm outer dia PVC/ABS Pipe with end caps including making air sampling operning of appropriate dia on appropriate interval. (DSR E&M 2022 4143) 559 Cost of fire survival armoured cable, fibre, fibre glass tape wrapped, ZH inner, outer sheath 2x1.5 sq. mm cable(DSR E&M 2022 4144) 560 Cost of fire alarm armoured FRLS cable 2 x 1.5 sqmm (DSR E&M 2022 4145) 561 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 562 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 563 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 564 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 565 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 566 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 567 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 568 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. (CSI No. 28.37) 569 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) 570 Supply & fixing steel tubular pole 7 Metre long designated 410 SP-2 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 2018 PWD 603 571 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 641 572 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 642 573 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131 574 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131(A) 575 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1132 576 Same as in item no. 1132 but of 6..5 kg. capacity 2018 PWD 1132 (A) 577 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge 2018 PWD 1133 578 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 579 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 580 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 2018 PWD 1421CAT AA 581 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66Protection complete in all respects.2018 PWD 1425(A)CAT AA 582 Supply and fixing of3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. 2018 PWD 1441CAT AAA 583 Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. 2018 PWD 1441 (A) CAT AAA 584 Supply and fixing ofdecorative 8 to 16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. 2018 PWD 1442CAT AAA 585 Supply and fixing ofdecorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and aboveprotection complete in all respect.2018 PWD 1443CAT AAA 586 Supply and fixing of 450mm size Exhaust fan of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 587 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 588 Supply and fixing of 200 mm Turbo ventilator Fan with ss Chimneycap & pipe of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 589 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 590 20-25 mm thick fine dressed Red sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.(NSI) 591 Providing/Laying 20-25 mm thick fine dressed Red sand stone flooring including supply of all materials, labour and T&P required for proper completion of work as perdirection of the Engineer-in charge.(NSI) 592 Providing and fixing prefab structure of size which does not require any structural steel frame at all heights of the existing building with following specifications: Manufactured by Epack polymers pvt ltd /Pronto panels Or Equivalent make.Walls: Outer & Inner walls made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The wall panels shall be connected to each other with Cam Locks @ 1.00 m C/C The walls shall be connected to the the base platform with 1mm thick channels & 100 to 150mm long dash fasteners. The walls & ceiling shall be connected to each other by 1mm thick flashing as per the manufacturer specifications. Any number of vertical partitions are to be provided in the structure as required at site & as per the directions of the E-in-C complete. All the inner / outer gaps, if any, are to be filled with silicon, rubber gasket or any material required complete & directions of the Engineer in charge.Ceiling: Made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The ceiling shall be extended from the wall on all sides by not less than 450mm & not more than 600mm with neccessary slopes in wall as required at the site & directions of the Engineer in charge complete. The outer edges of the roof shall be covered with the channel of the same material as of puff panel.Doors: Made out of 50 mm thick PUF insulated panels inner/outer side cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. complete with providing & fixing all accessories like locks, SS hinges, SS Tower Bolts,SS handles of required size not more than 300mm.Windows: The frame work shall be of aluminium work (Powder coated aluminium (minimum thickness of powder coating 50 micron)) for doors, windows(Sliding/Openable as required with requisite handles, tower bolts,20mm dia SS curtain rod & any other fitting required ), ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be of thickness not less than 14gauge, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing with 5.50mm thick glass / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. The outer surface shall have fly proof stainless steel grade 304 wire gauge, using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete .Strengthing of door, window, ventilators & any other opening : Any opening provided will have the framework strengthened with 1mm thick MS Plate on all sides all complete & directions of the Engineer in charge.Measurements: Only the floor area of the pre fab outer structure will be measured for payment purpose.Conditions Rates include all lifts, leads, depths, material, labour, scaffolding, all heights for location, carriage, wastage, tools and plants and other all inputs for execution of the item. The colour of the panels for walls & ceiling should be got approved from the E-in-C prior to start of manufacturing of the structure. The Structure requires approx five partitions in the two structures besides two outer walls . Note: The zinc sheet of the puff panels can either be plain/corrugated on both sides or one side plain & one side corrugated upto any pitch in horizontal / verticals per the drawings & requirement at site. 593 Supply,Installation, testing & commissioning Battery 12 V 7 AH Exide or equivalent make for above fire alarm system. Complete as per direction of the Engineer-in charge. 594 Supply,Installation, testing & commissioning Response Indicator Agni Suraksha or equivalent make. Complete as per direction of the Engineer-in charge. 595 Supply,Installation, testing & commissioning Camera (3 MP) colour W Audio IP Dome Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 596 Supply,Installation, testing & commissioning Camera (2 MP) IP Dome Falcon series Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 597 Supply,Installation, testing & commissioning NVR 8 channelSecureye or equivalent Indian make, with 4TBHDD Hard Disk. Complete as per direction of the Engineer-in charge. 598 Supply,Installation, testing & commissioning Connector D link or equivalent make Complete as per direction of the Engineer-in charge. 599 Supply,Installation, testing & commissioning 8 Port POE Switch Secureye or equivalent Indian make Complete as per direction of the Engineer-in charge. 600 Supply,Installation, testing & commissioning Cable (CAT6) D link or equivalent make Complete as per direction of the Engineer-in charge. 601 Servicing of Air Conditioner (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.30) 602 Servicing of Air Conditioner and filling of GAS (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.31) 603 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver setcomplete in all respect. 1401 PWD CAT AA 604 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. 1402 PWD CAT AA 605 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.1406 PWD CAT AA 606 P/F of 30 W orevo make or equivalent make LED light 30 Watt over Hoarding frame along boundary wall of MD DVVNL Campus, 220 KV S/S Sikandra , Agra with necessary materials , labour, T&P etc required for proper completion of the work as per direction of Engineer in charge. (NSI) 607 Providing and fixing of 20 W Philips make or equivalent make LED Tube light 20 Watt with necessary materials labour, T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI) 608 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 609 Supply and fixing of vertical blinds with hanging/sliding rod of aluminium (vista or equivalent make), vertical cord for operation of blinds, L-type hooks, screws, gullies etc. including all T&P, labour etc required for proper completion of the work in all respect. (NSI) 610 Printing name and designation of occupants and other information on residence block/office building including preparation of the base with best quality synthetic enamel paint as directed by E/I including cost of all materials, labour and T&P etc. required for proper completion of work. (NSI) 611 Providing and fixing of Name plate Acrylic/Glow sign Sheet per mm thick without letter as per approved shade and design as per direction of Engineer in charge (NSI) 612 Providing and Pasting of Name plate letter cutting words laser machine without name plate including cost of necessary all fittings such as nut, screws, labour T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI)
Contract Date: Apr 23, 2026 Contract Value : 21.94 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
15.
Defence #10169100 Price Bid
Tender For Category Vii ( Cardiology And Interventional Radiology ) , Medicals Items : , Coronary Guiding Catheter Guidliner / Guidezila ( Mother & Child ) Assorted Lengths , Disposable Cartridges For Analysis Of Sodium, Potassium, Ionized Calcium, Ph, Pco2, Po2 Hem Atocrit, Bicarbonate, Total Co2, Base Excess, O2 Saturation, Hb ( Eg7+ ) ( Box Of 25 Cartridges ) , Disposable Cartridges For Analysis Of Ph, Pco2, Po2, Total Co2, Bicarbonate, Base Excess, O2 Saturation, Lactate ( Cg4+ ) ( Box Of 25 Cartridges ) , Tr Band , Intra Aortic Balloon Pump, 30Cc 7 / 7.5 Fr , Intra Aortic Balloon Pump, 34Cc, 7 / 7.5 Fr , Intra Aortic Balloon Pump, 40Cc, 7.5 Fr , Balloon Mounted Covered Stent Grafts 5 / 6 / 7 / 8 Mm Diameterx 30Mm Or More Length , Rapid Exchange Balloon Dilatation Catheter 3.0 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Balloon Dilatation Catheter, 2.5 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Balloon Dilatation Catheter, 4.0 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Balloon Dilatation Catheter, 4.5 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Balloon Dilatation Catheter, With Zero Fold Technology 1.5 Cm Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Nc Balloon Dilatation Catheter, 2.5 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Nc Balloon Dilatation Catheter, 3.5 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Nc Balloon Dilatation Catheter, 4.0 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Nc Balloon Dilatation Catheter, 4.5 Mm X Assorted Lengths ( Us Fda Approved ) , Rapid Exchange Nc Balloon Dilatation Catheter, 3.0 Mm X Assorted Lengths ( Us Fda Approved ) , Runthrough Coronary Guide Wire , Terumo Angiography Guide Wire 0.035 X 260 Cm J Tip , Contrast Medium Iodinated Iodixanol Visipaque 320 Mg / Ml Bott Of 100Ml , Sheath 14 Fr 30 Cm , Extra Support Ptca Guidewire With Tip Load 0.5Gm And Silicon Coating Upto 2.5Mm From The Tip For Safer Procedure Slip Coat ( Hydrophilic Coating ) Of 18.5Cm After Silicon Coating From The Tip 1.5Cm And Composite Core Construction With Multiple Wire Components Comprising Of Rope Coil And Twist Wire Mountedon The Core Wire , Ptca Guide Wire With Tip Load 0.8 Gm And And Polymer Sleeve Length 16Cm. With Slip Coat ( Hydrophilic Coating ) And Diameter Of Wire 0.014 Inch With Tapered Tip Of Outer Diameter 0.009 Inch ( 0.23Mm ) . , Polymer Jacket Cto Ptca Guide Wire With Tip Load 1.0 Gm.And Tip Radiopaque Length 16Cm And Polymer Sleeve With Slip Coating Length Of 17Cm With Distally Tapered Tip Of 3Cms Of Diameter 0.010 Inch ( 0.26Mm ) And Composite Core Construction With Multiple Wire Components Comprising Of Rope Coil And Twist Wire Mountedon The Core Wire , Cto Ptca Guide Wire With Tip Load 3.5Gm And Micro Cone Tip For Superior Penetration Spring Coil Length Of The Wire 15Cm Total Hydrophilic Coating 40Cm And Composite Core Construction With Multiple Wire Components Comprising Of Rope Coil And Twist Wire Mountedon The Core Wire , Bib Premounted Covered Stent For Aortic Coarctoplasty ( Cp Covered Stent ) , The Innovative Compression System For Pacemaker / Icd Implantation Aftercare, To Prevent Pocket Haemotomo, Including Pressure Device Berliner Ufo Xl , Swan Ganz Flow Directed Three Lumen Catheter 7 Fr G With Introducer Kit , Embolization Coils 0.018 4Mm Diameter And 40Mm Length , Embolization Coils 0.018 5Mm Diameter And 50Mm Length , Embolization Coils 0.035 5Mm Diameter And 2 / 3 / 4 Cm Length , Ptfe Covered Self Expanding Nitinol Stent Graft Systemassorted Sizes , High Pressure 2 Port Manifold , Inflationdevice ( Indeflator ) Kitfor Angioplasty => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 15
Maharashtra View Result →
16.
Defence #10067904 Price Bid
Job Order For Energy Audit Of Sub Stations And Transformers At Af Stn Sirsa , checking of electrical system network , it should cover substations , sub station equipments , ac plants , pump houses , reactive power compensation , power factor improvement in metering etc . transformers ( 48 nos ) : the audit scope should include study of 48 transformers with ring main units and vacuum circuit breakers located at air force permises , their loading pattern , reconfiguration , renetworking , load balancing , losses and efficiency and possible suggestion to improve efficiency and life based on life cycle cost . electrical motors & pumps ( above 10hp ) : the operation of electric motors/pumps should be studied using appropriate instrumentation support to assess the loading pattern , power factor , flow operating efficiency and other operational parameters . this should also include detailed study of the mechanical power transmission system to evolve suitable recommendations wherever feasible for energy efficiency improvements . study of cooling towers associated with central ac plants . this should include detailed study of the operational performance of the cooling towers through measurements of temperature difference , air/water flow rate to enable evaluate specific performance parameters like approach , efficiency etc . study of lighting system of hangers and blast pens: a comprehensive study of the entire lighting system covering the light source ( lamps ) , luminiares ( reflectors etc ) , and the gears ( ballsts ) should be taken up . besides this the illumination levels required viz-a-viz available should also be studied . study of air conditioning & refrigeration system: the study should involve name plate details comparison with analysis of various parameters like co-efficient of performance , tonnage delivered , effectiveness of the ducting etc of the air conditioning systems . also the study should include the performance evalution of the allied system . green energy options and feasibility study . energy management policy and strategy . the reports would highlight the energy conservation opportunities ( ecos ) which are practically feasible in the plant along with the investments required and list of suppliers for installation of energy efficient equipments .
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
17.
Housing Urban and Rular Development #10040497 AOC
Construction Of Transit House At Angul- 1 Civil Work :- Clearing and grubbingland including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto a lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm in thickness as per Clause 201 of MoRT&H Specifications for Road & Bridge works Latest Revision & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge. 2 Earth workexcavation in foundation trenches in all kind of soil including dressing and leveling the bed up to required depth and depositing the excavated materials at places away from work site within 50mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge. 3 Up to 1.5Mtr Depth 4 Beyond 1.5Mtr to 3.00Mtr Depth 5 Disposal ofsurplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as perthe direction of the Engineer-in-charge. 6 Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance,loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. 7 Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge. 8 Supplying filling in foundation and plinth with sand in layers not exceeding 150mm thick including watering, ramming including cost, conveyance, royalty and taxes of all materials, all labour T&P required for the work etc. complete (measurement will be taken on finished compacted section only). 9 Cement concrete of propertion (1:4:8) in foundation and floors using 40mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and alllabour T&P required for the work etc. complete as per direction of the Engineer-in-charge. 10 Cement concrete of propertion (1:2:4) in foundation and floors using 12mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and alllabour T&P required for the work etc. complete as per direction of the Engineer-in-charge. 11 Cement concrete of propertion (1:3:6) in foundation and floors using 40mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and alllabour T&P required for the work etc. complete as per direction of the Engineer-in-charge. 12 RCC work of M-25 in all floors having a minimum compressive strength ( in work test) 250kg/cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 10mm size to 20mm size black hard crusher broken granite stone chips (10mm size 40% & 20mm size 60%) of approved quality & from approved quarry including hoisting lowering laying and compacting concrete with centering & shuttering and finishing the exposed surface smooth providinggrooves or beads where necessary and providing required No. of fan hooks as required including cost, conveyance, royalties and taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of MS rod / Tor steel and binding wire and labour charges for bending binding and tying the grills.(In all Floors) 13 A) Column base & footing 14 B) Plinth beam 15 C) Column & Roof Beam 16 Ground Floor 17 1st Floor 18 2nd Floor 19 3rd Floor 20 D) Lintel Band 21 i) Ground Floor 22 1st Floor 23 2nd Floor 24 3rd Floor 25 F) Roof slab 26 i) Ground Floor 27 1st Floor 28 2nd Floor 29 3rd Floor 30 G) Stair case 31 i) Ground Floor 32 1st Floor 33 2nd Floor 34 G) Chajja 35 i) Ground Floor 36 1st Floor 37 2nd Floor 38 RCC work of M-20 in all floors having a minimum compressive strength ( in work test) 200kg/cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 and IS 516 using 10mm size to 20mm size black hard crusher broken granite stone chips (10mm size 40% & 20mm size 60%) of approved quality & from approved quarry including hoisting lowering laying and compacting concrete with centering & shuttering and finishing the exposed surface smooth providinggrooves or beads where necessary and providing required No. of fan hooks as required including cost, conveyance, royalties and taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of MS rod / Tor steel and binding wire and labour charges for bending binding and tying the grills.(In all Floors) 39 A) Column base & footing 40 B) Plinth beam 41 C) Column & Roof Beam 42 D) RCC Wall 43 Labour charges for straightening the coiled or bend up M.S. rod / HYSD bars confirming to Gr.Fe-500, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel(Primary Producer like- SAIL/RINL/TATA/ JINDALSTEEL/ SHYAM STEEL) make) and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, couping, welded joints, spacer bar, chair, stage, hanger andbinding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987 in all floors.Ground Floor 44 Ground Floor 45 1st Floor 46 2nd Floor 47 3rd Floor 48 Fly Ash brick masonary using Fly Ash brick having crushing strength not less than 75kg/cm2 in cement mortar of (1:6) after immersing the bricks for six hours in water before use in Foundation & Plinth including splays cutting circular moulding corbelling champhering and similar such type of work watering and curing including cost conveyance royalty taxes of all materials and cost of all labour with T&P required for the work. 49 Fly Ash brick masonary using Fly Ash brick having crushing strength not less than 75kg/cm2 in cement mortar of (1:6) after immersing the bricks for six hours in water before use in superstructure including splays cutting circular moulding corbelling champhering and similar such type of work watering and curing including cost conveyance royalty taxes of all materials and cost of all labour with T&P required for the work in all floors. 50 i) Ground Floor 51 1st Floor 52 2nd Floor 53 3rd Floor 54 Fly Ash brick masonary using Fly Ash brick having crushing strength not less than 75kg/cm2 in cement mortar of (1:4) after immersing the bricks for six hours in water before use in superstructure including splays cutting circular moulding corbelling champhering and similar such type of work watering and curing including cost conveyance royalty taxes of all materials and cost of all labour with T&P required for the work in all floors. 55 i) Ground Floor 56 1st Floor 57 Providing 12mm thick cement plaster in cement mortar (1:6)finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. 58 i) Ground Floor 59 1st Floor 60 2nd Floor 61 3rd Floor 62 Providing 12mm thick cement plaster in cement mortar (1:4)finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. 63 Providing 16mm thick cement plaster in cement mortar (1:6)finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. 64 i) Ground Floor 65 1st Floor 66 2nd Floor 67 3rd Floor 68 Providing 6mm thick cement plaster in cement mortar (1:4)finished smooth to RCC work after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.Ground Floor 69 i) Ground Floor 70 1st Floor 71 2nd Floor 72 3rd Floor 73 Providing 25 mm thick Grading Concrete (1:2:2) using10mm to 6mm size chips finished smooth on roof slab etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.(Ground floors) 74 3rd Floor 75 Providing & installing two component acrylic modified cementitious waterproofing coating with masterseal 551/ Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 kg/sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect as per direction of the Engineer -in-charge. 76 Supplying, fitting, fixing of Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mmx600mm Colour/printed series of approved make in floors on 20mm thick bed of cement mortar (1:4) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, taxes, labour, labour cess T&P erc. required for the work complete in all respect as per direction of the Engineer-in-charge. 77 i) Ground Floor 78 1st Floor 79 2nd Floor 80 Supplying, fitting, fixing of Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mmx600mm Colour/printed series of approved make as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm cement plaster (1:3)jointed with white neat cement slurry mixed with pigment to match the shades of the tile including rubbing and polishing etc.complete with cost, conveyance, royalities and taxes of all materials labour, labour cess complete in all respect. 81 i) Ground Floor 82 1st Floor 83 2nd Floor 84 Supplying, fitting, fixing of 20 mm thick Granite Tilesin floors, treads, steps and landing slab on 20mm thick bed of cement mortar (1:4) joined with neat cement slurry mixed with pigments to match the shades of the tiles including polishing the surface with cost, conveyance, royality and all taxes of all materials etc. complete as per direction of the Engineer-in-charge. 85 i) Ground Floor 86 1st Floor 87 2nd Floor 88 Supplying, fitting, fixing of 10 mm thick Granite Tilesin floors, treads, steps and landing slab on 20mm thick bed of cement mortar (1:4) joined with neat cement slurry mixed with pigments to match the shades of the tiles including polishing the surface with cost, conveyance, royality and all taxes of all materials etc. complete as per direction of the Engineer-in-charge. 89 i) Ground Floor 90 1st Floor 91 2nd Floor 92 Supplying, fitting & fixing of 35mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality with frame of 1st class hard wood including cost of all door fittings and fixtures,conveyance of all materials labour and T&P require for the work etc.compolete as directed by Engineer-in-charge. 93 Supplying fitting and fixing of two track UPVC sliding window / ventilator of approved make with 6mm thick glass of approved quality complete with frame, shutter and all fitting and fixtures etc. complete as per specification & direction of Engineer-in-charge. 94 Supplying fixing and fittings MS window grills, Doors, MS verandha grills and MS grill gate of approved design and drawing made out of MS flat and MS angle at work site with one coat of anticorrosive red oxide zink chrome primer including cutting holes in brick or RCC walls and fixing with CC (1:3:6) including cost conveyance royalty and taxes of all materials all labour T&P required for the work complete (payment will be made on weight basis only) 95 Grill 96 Providing, Fitting & Fixing of Stainless steel of 304 grade in hand Railing of 50mm outer diameter of 2mm thick of approved Quality & Specification with balustrade of size 32mmX32mmX2mm square pipes in rows including Cost,conveyance of all Materials, Labour ,T&P required for fabrication, buffing & polishing, cost of all fixtures etc. complete and as per specification & direction of Engineer-in-charge (In all floors) 97 Painting two coats with synthetic enamel paints over a coat of primer including cleaning the surface with sand papering and using paints of approvedquality and approved shade including cost conveyance taxes of all materials all labourT&P etc. complete as directed by the Engineer in charge. 98 i) Ground Floor 99 1st Floor 100 2nd Floor 101 Painting 2 coats with Plastic Emulsion paints over a coat of primer and putty of approved shade by means of brush to inside surface of walls after cleaning the surface etc. complete in all floors including cost of all materials with all taxes and cost of all labour with T&P required for the work etc. complete in all respect as directed by Engineer – in – Charge. 102 i) Ground Floor 103 1st Floor 104 2nd Floor 105 3rd Floor 106 Painting two coats with weather coat paintof approved shade over a coat of primer by means of brush to outside surface of walls complete in all floors with cost, carriage and all taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect as per direction of the Engineer – in – Charge. 107 i) Ground Floor 108 1st Floor 109 2nd Floor 110 3rd Floor 111 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size well rammed ,with side rcc wall and consolidated and grouted with fine sand including finishing the top smooth including watering, curing, cost, conveyance, royalties, taxes of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. 112 Providing and fixing Glass Reinforced Concrete (G.R.C) Jallis in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with layering technique Power Spray methodology have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens casting shall take place with layering methodology using- Direct Power Spray machines. The screens shall be casted from ‘53 grade’ White Portland Cement fine graded, sieved Quartz & Silica Sand, reinforced with Alkali Resistant Glass Fiber manufactured between 4-5%having Zirconia content at least 16%, Super Plasticizersand U.V resistant Synthetic inorganic pigments should be used. 113 The material casting should take place in FRP Molds. The GRC Panels flexural strength average L.O.P should be above or equivalent to 6 N/mm2 & M.O.P should be above or equivalent to 15 N/mm2 for tests done on 28 days cured samples. The fixing of panels should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners & Self Tapping screws or as per approved shop drawings approved by site engineer in charge. 114 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 115 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: 116 Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: 117 Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of buildingstructure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. 118 Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass 119 Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight 120 Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checkedby a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. 121 The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. 122 Loosening to a depth of 150mm,levelling and compacting original ground supporting embankment/ sub-grade as per approved drawing andtechnical specifications complete in all respect as per Section 900 and Clause 305 of MoRT&H Specifications for Road and Bridge works (latest Revision) & including cost of all labour, T&P, royalty etc. complete and including cost of all labour, T&P,etc. complete and as per direction ofEngineer-in-charge. 123 Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide Clause No. 801.3 of specifications for road and bridge works of Ministry of Road Transport & Highways (Latest Revision) fixed over aluminium sheeting, 1.5mm thick with area exceeding 0.9 Sqm supported on a mild steel angle iron post 75mm x 75mm x 6mm , firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing& including cost of all materials, labour, T&P, royalty etc completein all respect and as per direction of the Engineer-in-charge. 124 Providing wet mix macadum using crushed stone aggregates as per approved drawing and technical specification complete in all respect as per Section 900 and Clause 406 of MoRT&H Specifications for road & Bridge works(latest Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc. complete and as per direction ofEngineer-in-charge. 125 Supplying and fixing of 80mm thick cement concrete interlocking paver block of M -40 gradeof approved make design, colour & size made by Block machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018 as per the direction of Engineer-in-charge 126 Supplying and fixing of Kerb Stone of size 600X300X150mm of M -30 gradeof a pproved make design, colour & size made by Block machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS - 5758:1984as per the direction of Engineer-in-charge 127 Providing and fixing 12.5mm thk. Gypsumboard false ceiling consisting of G.I. perimeter channels of size 0.55 thick, screw fixed to brickwall/partition with the help of nylon sleeves and screws, at 610mm centres. The suspending G.l.intermediate channels of size 45mm, 0.9mm thick with two flanges of 15mm each from the soffite at 1220mm centres with ceiling angle of width 25mm x 10mm x 0.55 thick fixed to soffite with G.I. cleat and steel expansion fastners at every 610mm c/c.12.5mm tapered edge Gypsum board is then screw fixed to ceiling section with 25mm drywall screws The boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edge of the boards with jointing compound & joint paper tape as per approved design and specificatinetc.fitted and fixed in position etc. with cost, conveyance, taxes of all materials, labour, T&P required for complete in all respectas per the direction of Engineer -in-charge. 128 Supplying,fitting ,fixing of grid mineral fibreceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fiotting and fixtures in all respect as per the direction of the Engineer -in-charge. 129 Supplying and fixing of wall panelling made of aluminum anodised section framing confirming to standard aluminium section as horizontal and vertical members with atleast 600 mm c/c with 9mm thick BWR block ply and 4mm thick veneer pasting finished with melamine polished completein all respectas per the direction of Engineer -in-charge. 130 P.H WORKS :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 131 20mm dia C- PVC pipe SDR - 11 132 Ground Floor 133 First Floor 134 Second Floor 135 25mm dia C- PVC pipe SDR - 11 136 Ground Floor 137 First Floor 138 Second Floor 139 32mm dia PVC ASTM pipe (sch-80) 140 40mm dia PVC ASTM pipe (sch-80) 141 Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materialsincluding cost & conveyance of all materials to worksite, payment oftaxes etc. allcomplete as per P.H specification and direction of the Engineer-in-charge. 142 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) 143 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) 144 15 mm dia CP S.B. Bib cock(CON-CHR-037KN) 145 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) 146 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) 147 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) 148 25mm dia brassfull way valve (Shakti make) 149 32mm dia brassfull way valve (Shakti make) 150 40mm dia brassfull way valve (Shakti make) 151 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) 152 gyser ELM-WHT-V006 153 WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR) 154 Hand Dryer SMART FLOW (As per Cat no HDR-WHT-M04A of Jaquar) 155 15mm CP Extension piece 156 125mm CP grating 157 15mm size C.P. flange 158 25mm size brass ball cock with ball 159 Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction ofEngineer-in-charge 160 2000 liters capacityPVC water storage tank roof of 2nd floor 161 supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite,payment of royality, taxes etc. all complete as perdirection ofEngineer-in-charge. 162 Ground Floor 163 First Floor 164 Second Floor 165 Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge 166 Ground Floor 167 First Floor 168 Second Floor 169 Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damagesincluding watering ,curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. 170 Ground Floor 171 First Floor 172 Second Floor 173 Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment oftaxes etc.all complete as per P.H specification and direction of the Engineer-in-charge. 174 110mm U-PVC SWR Pipe (Supreme /Ashirvad) 175 110mm U-PVC‘P’ Trap(Ori Plast/Finolex/Supreme Make) 176 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) 177 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) 178 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) 179 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) 180 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) 181 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) 182 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) 183 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) 184 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) 185 Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI p or s trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 186 580mm size Orissa pan (Hindware/Parryware/Neycer make) 187 Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge 188 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) 189 Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral p or s trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 190 One piece commod(Hindware)ELEMENT Cat No.92084. 191 Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge 192 Halfpedestalbasin(560x450)Hindware No.91049+91115 193 Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink 194 Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 195 25mmx600mm long CP towel rail 196 Towel ring 197 Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 198 600mmx125mm plate glass shelf with CP/NP guard rails. 199 Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 200 600mmx450mm size B.E mirror (swivelled type) 201 Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 202 CP soap holder 203 Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. 204 ½” x 5” CP Shower (Plaza Deluxe Make) 205 Supplying all materials , labour, T&P and cutting holes through existing brickor laterite masonry wall for takingU-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge 206 Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge 207 Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge 208 Inside size 76cmx76cmx46cm with 18” dia RCC MH cover 209 Supplying all materials ,labour ,T&P and constructing gully trap chamber ofinside size 250mmx250mmwith 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinthand inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI gratingetc.all complete as per drawing,specification and direction of Engineer-in-charge 210 Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. 211 Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge 212 Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge 213 Ground Floor 214 First Floor 215 Second Floor 216 Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( Vitrifiedfloor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed seriesto be pre-approved by the Engineer-in-charge ) 217 Kajaria/Somany/Johnson tile 60cmx60cm 218 Ground Floor 219 First Floor 220 Second Floor 221 Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. 222 Ground Floor 223 First Floor 224 Second Floor 225 Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirtingon 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tilesincludingwatering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( Vitrified mat finish wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) 226 Kajaria/Somany/Johnson tile 60cmx30cm 227 Ground Floor 228 First Floor 229 Second Floor 230 Granite Tiles 10mm thick 231 Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centres standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. 232 Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge 233 Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liters along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge 234 Aqua guard pure Chill 80 PSS UV 235 Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufactures specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 236 100mm dia P.V.C. pipe 237 150mm dia P.V.C. pipe 238 Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. 239 MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) 240 Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. 241 1 no 50 users RCC septic tank 242 Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge. 243 Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 244 Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. 245 Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. 246 Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 247 Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 248 Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 249 Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 250 R.C.C beams,columns,girder and bressmer etc. 251 Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 252 Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 253 Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 254 Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 255 Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 256 Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. 257 Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 258 Construction of 20000 Liters RCC Under ground Reserverof Inside size- 4.00 X 3.00 X2.00m 259 Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. 260 -do- with Ist additional depth of 1.50 m over the initial lead and lift 261 Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. 262 Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 263 Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. 264 Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. 265 Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. 266 RCC floor roof, chajja etc 267 RCC Beam, Column, wall etc 268 RCC Plinth bend/ Raft 269 Base slab 270 Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. 271 Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. 272 Quantity same as item No-4 273 Providing fitting and fixing CI/MS step iron including fixing to walletc. complete 274 Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge 275 Construction of 1 no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories 276 Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only 277 Drilling of 200mm dia bore 278 00 mtr to 30mtr 279 30 mtr to 45mtr 280 Drilling of 150mm dia bore 281 45 mtr to 215.00mtr 282 Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. 283 Lowering of 200mm dia P.V.C casing pipes 284 00 mtr to 30 mtrs 285 30 mtr to 60mtr 286 Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber O ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 287 200mm dia PVC (sch-80) pipe 288 Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) 289 Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge 290 By DTH Rig 291 Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: 292 Rocky terrain with boulder formation for 300m depth 293 Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 294 1 H.P. Single phase/ three phase 3 stagehead renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) 295 DOL Control panel 296 40mm dia steel short piece 297 Well cap 298 50mm size CI bracket 299 2.50sqmm flat cable 300 20mm dia rigid UPVC pipes 301 Steel rope with cover 302 Labour charges for lowering including transportation 303 Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge 304 32mm HDPE pipes (Finolex/Supreme make) 305 E.I Works :- Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels /HPL/ V Guard ) Group-ALP-54 306 Group-B LP-77 FP-27 307 Group-CLP-132,FP-28Ex FP-19CBP-8 308 Supply and fixing of 6Amp plugwith 6Amp switch on existing board. (Modulartype)(Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) 309 Point wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copperconductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with Modular type switch ,phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 x 1.5 sq.mm FR PVCinsulated single core multistrand copper conductor for loop earthing etc. as required. 310 Supplying and fixing of 3 nos 6 Amp Plug point 3 nos switch, 1 No 15 Amp Switch & 1 No 15 Amp Socket Modular type on modular metal box, base & cover with all connections.(Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) 311 Supplying and fixing of 15/16 Amp Plug point Modular type on modular metal box on surface/Recess with suitable size of Modularcover in front including cutting the wall and making good the same in cases of recessed conduit as required(Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) 312 s/f of ac point consisting of 32Astarter with all connection compelete s per the direction of engineer in charge 313 Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulatedsingle core multistrand copper conductoras earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL) 2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia 314 2 X 2.5 sq.mm +1 X 1.5 sq.mm-do- 315 2 X 4 sq.mm +1 X 1.5 sq.mm -do- 316 2 X 6 sq.mm +1 X 2.5 sq.mm in 25mm dia 317 4 x 6 sq.mm + 2 x 2.5 sq.mm) 318 4 x 10 sq.mm + 2 x 4 sq.mm) 319 Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc ( with charcoal and salt) as required. 320 Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required 321 Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.)4 way (4+12) double door horizontal type 322 Supply and fixing of 5Amp to 32A rating 240 V/415 V c series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-HPL/ Havells/ Legrand /L&T/C&S)Single pole (SP) 323 S/F of 34/36 Watt (2 x 2)LED round/ square surface ceiling Lights .(Make-Havells/Crompton/Philips/Bajaj)) 324 Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required. 325 S/F. Of 400mm Wall fans including all connections and accessories of Usha/Orient/Havells/Equivalent make 326 s/f SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories withdiffuser having 2 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .of tube light18watt /20 watt ledfitting with cover( Make-Havells/ Philips/Cromptonas per the direction of side engineer in charge. 327 S/F. Of 48AC Ceiling fans including all connections and accessories of Usha Allure Dlx/Havells Pacer/Orient Summer Pride/Equivalent make. 328 Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. 329 S/F. of 45Wt. LED Street light fittings complete with G.I. bracket. Of Bajaj/Havells/Crompton/Philips make. 330 S/F of 18Watt Recess/Surface mounted LED downlighter with white powder coated aluminium housing with integrated electronic driver.(Make-Havells/Crompton/Philips/Bajaj)) 331 s/f of decorative foot light (Make-Havells/Philips/Crompton or equivalent.) 332 Supply of 35 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked 333 Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. 334 S/F of 30x6x10no 16/18 SWG sheet metal for main 250 amp panel board having125 amp MCCB 25 KA-1no as incommer,200 amp electrolyte cu bus bar-1no andammeter and voltmetertoggler switch,three nos led indicator and as per the direction of site engineer in charge.(make: Siemens / legrand/Schneider/Equivalent)) 335 Approved for 97 ( One hundred eight) items only
Contract Date: Apr 22, 2026 Contract Value : 2.67 Crore
Government Departments No of Bidders 3
18.
Drinking Water Supply and Sanitation #9954494 Technical Bid
Tender for For Setting Up Instrumentation And Equipments For Qc Lab For Qc Wing Of Wrd With Mobile Unit, (Package No- 170) , Survey Equipments , Trimble Total Station, For Survey, 6 Km , Leica Auto Level B40a With Aluminium Telescopic Tripod And 5 Meter Aluminium Leveling Staff , Measuring Tape (5Mtr, 10Mtr, 30Mtr, 50Mtr) , Digital Planimeter Kp 90N , Range Pole , Prism With Pole Extra , Leveling Staff Extra , Survey Umbrella , Aloy Sokkia Gnss Dgps, For Survey, Packaging Type: Box , Cement And Concrete Testing Equipments , Computerised Univercal Testing Machine Digital , Semi Automatic Compression Testing Machine , Cube Mould - Isi (150*150*150)Mm , Cube Mould - Isi (50*50*50)Mm (Non Isi) , Flow Table (Motorized) Concrete , Flow Table (Motorized) Mortar , Flow Table (Manual) , Ve Bee Consistometer , Slump Test Apparatus-Mortar , Slump Test Apparatus-Concrete , Compaction Factor Apparatus , Lab. Concrete Mixer (Motorized) , Cement Mortar Mixer , Cone Penetrometer For Mortar , Le Chatelier Mould , Le Chatelier Flask , Blaine Air Permeability Apparatus , Cement Autoclave For Testing Soundness Of Cement At Balanced Steam Pressure With The Stable Temperature. , Vibrating Table , Mortar Cube Vibrating Machine , Tensile Strength Tester (Elec.) , Briquette Mould (Single/Three) , Pocket Concrete Penetrometer , Capping Set , Accelerated Curing Tank , Automatic Flexural Testing Machine , Bleeding Of Fresh Mixed Concrete , Geotechnical Engineering Lab Equipments , Plastic Limit Apparatus , Shrinkage Limit Set Apparatus , Soil Cone Penetrometer , Soil Hydrometer , Liquid Limit Device (Motorized) , Grain Size Analysis (Pipette Method) , Proctor Compaction Test Apparatus (Universal Automatic Compactor) , Infrared Moisture Meter , Rapid Moisture Meter , Core Cutter , Universal Permeability , Permeability-Falling Head Test , Relative Density Test , Sampling Tubes , Auger Posthole Type , Digital Direct Shear Test Apparatus , Digital Triaxial Shear Test Apparatus , Laboratory Vane Shear Apparatus , Standard Test Sieves 20Cm Diameter Complete With Lid And Pan , (Spun Br Ass Frame) (Set Of 8Seives) , Standard Test Sieves 30 Cm Diameter Complete With Lid And Pan , (G.I. Sheet Frame) (Set Of 10Seives) , Gyratory Sieve Shaker , Manual Sieve Shaker , Sand Replacement Apparatus , Digital Plate Load Test Apparatus , California Bearing Ratio [Cbr] Test Machines , Swell Pressure Test Machine , Bullet End Concrete Tamping Rod , Concrete Core Cutter Test , Core Cutting/ Drilling Machine (Motorized) , Diamond Core Bits , Core Cutting Grinding Machine , Aggregate Test Equipments , Flakiness Test Gauges As Per Is 2386-1963 (P-1) , Elongation Test Gauges As Per Is 2386-1963 (P-1) , Cylindrical Measures (Complete Set 3 Ltr To 30 Ltra) , Aggregate Crushing Value Apparatus , Aggregate Impact Value Tester Apparatus , Los Angeles/Abrasion Testing Machine , Dorry Abrasion Testing Machine , Environmental Engineering Lab Equipments , Digital Ph Meter , Digital Water And Soil Testing Kit , Digital Turbidity Meter , Conductivity-Tds Meter , Measuring Instruments And Tools , Sampling Trays (All Size Set) , Measuring Tapes Size 3Mtrs, 5Mtrs, 7.5Mtrs, 15 Mtrs, 30 Mtrs, 50 Mtrs, 100 Mtrs , Graduated Measuring Jars (Set-5Ml To 2000Ml) , Scoops & Shovels- All Sizes , Laboratory Oven , Enamel Trays (Set Of Size: 10 X 12, 12 X 14, 18 X 14, 8 X 10, 19 X 24) , Spatulas Set Of All Size , Trowels Set , Laboratory Trolley , Tool Kit , Portable Electronic Balances (Upto 50 Kg) , Cement Sampler , Safty Helmate , Safty Jaccket , Safty Boots , Advanced Technology , Desktop Computer Mid-High Level Configuration (Intel I7 With 14Th Generation (Estimated Cost Rs. 90,000 Considering Pre-Installed Genuine Windows 11 Profesional, 16 Gb Ram And 1 Tb Storage) , Laptop-Intel I5, Minimum 4 Core Or Higher, 12Mb Cache Or Higher 13Th Or Higher Generation And To Be Certified By Ome , Split Ac With Inverter Compressor: Capacity: 2 Ton. Energy Rating: 5 Star. Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products. (2.0 Tr Iseer Not Less Then 3.8)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
19.
Water Resources and Irrigation #9943546 Technical Bid
Tender For Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge. All Kinds Of Soil , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Electric Resistance Or Induction Butt Welded Tubes , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate , 12 Mm Cement Plaster :1:4 (1 Cement : 4 Coarse Sand)With A Floating Coat Of Neat Cement Punning. , Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing And Fixing At Or Near Ground Level Precast Cement Concrete In Kerbs, Edgings Etc. As Per Approved Pattern And Setting In Position With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including The Cost Of Required Centering, Shuttering Complete. 1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Supplying Of Earth In Rough Excavation, Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks For Filling Up Ground Depresssion Lead Upto 15 Km And Lift Upto 1.50 M. , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:4 (1 Cement : 4 Coarse Sand , Providing And Laying Cement Concrete In Retaining Walls, Return Walls,Walls (Any Thickness) Including Attached Pilasters, Columns, Piers,Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets,Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering,Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Washed Stone Grit Plaster On Exterior Walls Height Upto 10Metre Above Ground Level,In Two Layers,Under Layer12Mm Cement Plaster 1:4 (1 Cement : 4 Coarse Sand ), Furrowing The Under Layer With Scratching Tool,Applying Cement Slurry On The Under Layer @ 2 Kg Of Cement Per Square Metre, Toplayer 15Mm Cement Plaster 1: 1/2:2 (1Cement: 1/2 Coarse Sand : 2 Stone Chipping 10Mm Nominal Size), Inpanels With Groove All Around As Per Approved Pattern,Including Scrubbing And Washing The To Player With Brushes And Water To Expose The Stone Chippings,Complete As Per Specification And Direction Of Engineer-In- Charge (Payment For Providing Grooves Shall Be Made Separately). , Extra For Washed Grit Plaster On Exterior Walls Of Height More Than 10 M From Ground Level For Every Additional Height Of 3 M Or Part Thereof. , Forming Groove Of Uniform Size In The Top Layer Of Washed Stone Grit Plaster As Per Approved Pattern Using Wooden Battens, Nailed To The Under Layer, Including Removal Of Wooden Battens, Repair To The Edges Of Panels And Finishing The Groove Complete As Per Specifications And Direction Of The Engineer-In-Charge :20 Mm Wide And 15 Mm Deep Groove , Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M), Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Of Wall With Existing Angle Iron Y Shaped Placed 2.4 M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape(R.B.T.) / Spring Core (2.5Mm Thick) Wire Of High Tensile Strength Of 165 Kg/ Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/ Metre (Cost Of M.S. Angle, Cement Concrete Blocks Shall Be Paid Separately) , Constructing Brick Masonry Road Gully Chamber 50X45X60 Cm With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including 500X450 Mm Pre-Cast Reinforced Cement Concrete Horizontal Grating With Frame Complete As Per Standard Design : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Plain Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana/Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is:9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering And Finishing As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Minimum Specified Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level : Concrete Of M10 Grade With Minimum Cement Content Of 220 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Fixing In Position Pre-Cast Reinforced Cement Concrete Manhole Cover And Frame Of Required Shape And Approved Quality Ehd - 35 Circular Shape 560 Mm Internal Dia , Providing And Laying Neelgiri/Mexican Grass Turf With Earth 50Mm To 60Mm Thickness Of Existing Ground Prepared With Proper Level And Ramming With Tools Wooden (Dhurmos) And Than Rolling The Surface With Light Roller Make The Surface Smoothen And Light Waterning With Sprinkler And Maintenance For 30 Days Or More Till The Grass Establish Properly, As Per Direction Of Officer-In-Charge. , Digging Holes In Ordinary Soil And Refilling The Same With The Excavated Earth Mixed With Manure Or Sludge In The Ratio Of 2:1 By Volume (2 Parts Of Stacked Volume Of Earth After Reduction By 20% : 1 Part Of Stacked Volume Of Manure After Reduction By 8%) Flooding With Water, Dressing Including Removal Of Rubbish And Surplus Earth, If Any, With All Leads And Lifts (Cost Of Manure, Sludge Or Extra Good Earth If Needed To Be Paid For Separately) : Holes 90 Cm Dia, And 90 Cm Deep , Preparation Of Beds For Hedging And Shrubbery By Excavating 60 Cm Deep And Trenching The Excavated Base To A Further Depth Of 30 Cm, Refilling The Excavated Earth After Breaking Clods And Mixing With Sludge Or Manure In The Ratio Of 8:1 (8 Parts Of Stacked Volume Of Earth After Reduction By 20% : One Part Of Stacked Volume Of Sludge Or Manure After Reduction By 8%), Flooding With Water, Filling With Earth If Necessary, Watering And Finally Fine Dressing, Leveling Etc. Including Stacking And Disposal Of Materials Declared Unserviceable And Surplus Earth By Spreading And Leveling As Directed, Within A Lead Of 50 M, Lift Up To 1.5 M Complete (Cost Of Sludge, Manure Or Extra Earth To Be Paid For Separately) , Supplying And Stacking Of Well Decayed Cattle Manure At Site Including Royalty And Carriage Upto 5 K.M. Lead Complete (Cattle Manure Measured In Stacks Will Reduced By 8% For Payment). , Filling Mixture Of Earth And Sludge Or Manure In The Desired Proportion In Trenches, Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing And Fixing M. S. Tree Guard 45 Cm Square In Plan, Height 1.20 Metre Above Ground Level And 0.40 Metre Below Ground Level. The Vertical Members Shall Consist Of Four Nos. Angle Iron Of Size 25X25X3 Mm, 1.6 M Long, One At Each Corner And 8 Nos Flat Iron Of Size 25X3 Mm, 1.2 M Long. The Vertical Members Shall Be Welded To 4 Nos. 25X6 Mm M. S. Flats Placed Horizontally Around The Vertical Member Of The Cage. One Name Plate Of 1 Mm Thick M.S. Sheet Of Size 250X100 Mm Shall Be Welded To The Tree Guard Near The Middle Height And Lettered Cpwd/ Pwd/ Any Other Approved Name. The Tree Guard Shall Be Fixed To The Ground By Making Suitable Holes And By Embedding Four Corners Leg In The Ground, Including Refilling The Earth, Compaction Etc. Complete. The Tree Guard Shall Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Approved Brand And Manufacture Over A Coat Of Primer, Complete In All Respect. , Tree Plants Of Height 5-6 Such As Sevel/ Alestonia Big Poly Bag Including Cartage , Loading Unloading And Planting The Plant At Site . , Tree Plants Of Height 6-7 Such As Molsri 10 E. Pot Including Cartage , Loading Unloading And Planting The Plant At Site . , Ficuss Panda 2.5-3 In 10E.Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Shrubs 4-5 Height Such As Peli Kanier In 10 Earthen Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Chandni (Variegated) Of 2 To 2.5 Height 10E/Pots Well Grown.Including Cartage , Loading Unloading And Planting The Plant At Site . , Boganvillia Named Variety 2 To 3 In 10 E.Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Ashok Pendula 8-9 Height In 12 E. Pot Including Cartage , Loading Unloading And Planting The Plant At Site . , Ficus Benjamina 3 To 4 In 10 E.Pot Well Grown Including Cartage , Loading Unloading And Planting The Plant At Site . , Plumaria Alba Round Leaves Well Grown 3-4 Branches 4-5 Height In 12 E. Pot Including Cartage , Loading Unloading And Planting The Plant At Site . , Hedges 1-2 Height Such As Putranjiva, Poly Bag.Including Cartage , Loading Unloading And Planting The Plant At Site . , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , Providing And Placing In Position 100 Mm Thick Factory Made Machine Batched & Machine Mixed Precast Reinforced Cement Concrete Rectangular Covers On Drains Of Footpath Of Various Sizes, Of M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Including Cost Of Centering, Shuttering, Reinforcement Of 8 Mm Dia Tmt Bars Of Fe 500 Grade @ Maximum 100Mm C/C On Both Ways , Neat Cement Punning On Finished Surface, Properly Encased On All Edges With 1.6 Mm Thick , 100 Mm Wide Ms Sheet Duly Painted Over Priming Coat , Reinforcement To Be Welded At Edges With Ms Sheet And Providing 2 Nos. 12 Mm Dia Bar For Hooks Etc I/C Cost Of Cartage, All Leads & Lift, Handling At Site Etc. All Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge.( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Manufacturing, Supplying Fixing Retro Reflective Overhead Signage Boards & Removing Of Existing Damaged Retro Reflective Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity And Encapsulated Lens Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iii Of Astm-D-4956-01 As Approved By Engineer-In-Charge, Letters, Borders Etc. As Per Irc : 67-2001 In Silver White With Blue Colour Back Ground And With High Intensity Grade, Pasted On Substrate By Pressure Sensitive Adhesive Backing Which Shall Be Activated By Applying Pressure Conforming To Class Ii Of Astm-D-4956-01 And Fixing The Same To The Plate Of Structural Frame Work By Means Of Suitable Sized Aluminium Alloys, Rivets Or Bolts & Nuts @ 300 Mm Centre To Centre All Along The Periphery As Well As In Two Vertical Rows Along With Theft Resistant Measures, Including The Cost Of Painting With Two Or More Coats Of Epoxy Paint In Grey Colour On The Back Side Of Aluminium Sheet Including Appropriate Priming Coat. The Rate Includes The Cost Of Rounding Off The Corners, Lowering Down The Structural Frame Work From The Gantry, Fixing And Erecting The Same In Position All Complete As Per Drawings, Specification And Direction Of The Engineer-In- Charge.(Structural Frame Work Including M.S. Plate To Be Provided Separately. Rectangular Area Of The Sheet Only Shall Be Measured For Payment). Overhead Informatory Road Signage, , Stone Tile (Polished) Work For Wall Lining Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Cement Slurry @ 3.3 Kg/Sqm Including Pointing In White Cement Complete 8Mm Thickgranite Of Any Colour And Shade , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:5:10 (1 Cement : 5 Coarse Sand (Zone-Iii): 10 Graded Stone Aggregate 40 Mm Nominal Size). , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , Providing And Laying Gang Saw Cut 18 Mm Thick, Mirror Polished Pre Moulded And Pre Polished Machine Cut Granite Stone Of Required Size And Shape Of Approved Shade, Colour And Texture In Footpath, Flooring Cut Granite Stone Of Required Size And Shape Of Approved Shade, Colour And Texture In Footpath, Flooring In Road Side Plazas And Similar Locations, Laid Over 20Mm Thick Base Of Cement Mortar 1:4 (1Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement Mixed With Matching Pigment, Epoxy Touch Ups Etc. Complete As Per Direction Of Engineer-In-Charge. With Granite Stone Of Area Less Than 0.50 Sqm. , Providing And Fixing Bolts Including Nuts And Washers Complete. , Designing, Fabricating, Testing, Installing And Fixing In Position Curtain Wall With Aluminium Composite Panel Cladding, With Open Grooves For Linear As Well As Curvilinear Portions Of The Building , For All Heights And All Levels Etc. Including: (A) Structural Analysis & Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design. (B) Providing, Fabricating And Supplying And Fixing Panels Of Aluminium Composite Panel Cladding In Pan Shape In Metalic Colour Of Approved Shades Made Out Of 4Mm Thick Aluminium Composite Panel Material Consisting Of 3Mm Thick Fr Grade Mineral Core Sandwiched Between Two Aluminium Sheets (Each 0.5Mm Thick). The Aluminium Composite Panel Cladding Sheet Shall Be Coil Coated, With Kynar 500 Based Pvdf / Lumiflon Based Fluoropolymer Resin Coating Of Approved Colour And Shade On Face # 1 And Polymer (Service) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc (C) The Fastening Brackets Of Aluminium Alloy 6005 T5 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing The Item Includes Cost Of All Material & Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminium Composite Panel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminium Composite Panel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work For Acp Cladding Is Payable Under The Relevant Aluminium Item.S The Contractor Shall Provide Curtain Wall With Aluminium Composite Panel Cladding, Having All The Performance Characteristics All Complete , As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer-In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Composite Panel Cladding (Including Width Of Groove) Shall Be Measured In Sqm. Up To Two Decimal Places. , Providing & Fixing Backlit Signage Of Size 80 Ft X 3Ft Made Out Of Acp Of 3Mm Thickness With Ms Framework With 3D Cut Letters On The Acp. Having Ip 68 Rated Samsung Chip Leds Of 10000K With 140Lumens Per Feet For Brightness & Uniform Illumination With No Hotspots Including Material, Labour Charges, Freight Charges Etc Complete With 1 Year Warrenrty On Complete Product And Per Direction Of Engineer-In-Charge. , Supplying And Installation Testing And Commossioning Of 40 Watts Smart Intergarated All In One Solar Light Of Highty Effeciency Solar Panel Led Light And Long Lite Po4 Battery With High Effieciency Micriprocessor-Based Charge Controller Per Motion Sensor And Compact In Size Complete Etc As Required Make Bajaj /Volmont/Phillips/Lysaght/Havells). , Supplying And Installation Led Wall Light , Energy Saving, Decorative Ip 66 Led Up-Down Luminaire With Wall Surface Mounting Using Cob Led As Light Source As Required Make Bajaj /Volmont/Phillips/Lysaght/Havells). , Supply Of 150 Led Luminaire For Flood Light With Warranty For Free Replacement 1 Year 140 To 270 Volts Ac At 50 Hz+/-2 Hz With Auto Cutt Off At Below 120V, Including All Wiring, Circuity, Switch & Installation (Make For Led Street Light Bajaj, Cropton, Orient Or Equivalent). , Providing, Fixing Erection And Testing Of 3G.I. Pole Decorative Street Light Of 6 Mtr. Hight Having Base Plate Welded On Bottom Of Pipe Of Suitable Thickness With Foundation Including Excvation Shuttering And Cement Concrete Complete Etc As Required And As Per Direciton Of The Engineer-In-Charge At Site. , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications ,Duplex Maps D01 As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Combination Set 3 In 1,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Frp Wave Slide 2.1 Mtr., As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Toddler Swing, As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Standard Swing,,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Circular Swing,Simply Go Round,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Half Round Net,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Std. See-Saw (Double),As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Spring Rider Jumboas Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil. Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia , Supplying And Filling In Plinth With Sand Under Floors Including, Watering, Ramming Consolidating And Dressing Complete. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Ill) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , (74) Centring And Shuttering Including Strutting, Propping Etc. And Removal Of Form For (74.I) Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. , (74.Ii) Suspended Floors, Roofs, Landings, Balconies And Access Platform. , (74.Iii) Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , (74.Iv) Columns, Pillars, Piers, Abutments, Posts And Struts , Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide , Weather Shade, Chajjas, Corbels Etc., Including Edges. , Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc., Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.5 M, For Every Additional Height Of 1 Metre Or Part Thereof (Plan Area To Be Measured). Suspended Floors, Roofs, Landing, Beams And Balconies (Plan Area To Be Measured) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo -Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying Damp-Proof Course 50 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Lll) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Of Colour Black, Cherry/Ruby Red Or Equivalent , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Stone Slab Of All Colour And Texture Except Black, Cherry/Ruby Red Area Of Slab Upto 0.50 Sqm , Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide Pa 6 Grade Sleeve, Including Drilling Of Hole In Frame , Concrete/ Masonry, Etc. As Per Direction Of Engineer-In-Charge.10 X 120 Mm , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings /Wooden Frames With Rawl Plugs Screws Etc. , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Oarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sgm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To 1S: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) : 100X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) : 125 Mm , Providing And Fixing Is : 12817 Marked Stainless Steel Butt Hinges With Stainless Steel Screws Etc. Complete : 125X64X1.90 Mm , Providing And Fixing Aluminium Sliding Door Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc. Complete :250X16 Mm , (90) Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : (90.I) 150X10 Mm , (90.Ii) 100X10 Mm , (91) Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : (91.I) For Fixed Portion Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately).Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item) :With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On Both Sides. , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors, Including Cost Of Cutting Floors, Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mmthickness , Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia,3.0 Mm Thick & 2100 Mm Long With Ss Screws Etc .Complete As Perdirection Of Engineer-In-Charge.Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar , Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations:(E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge:With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : In 75X75Mm Deep Chase , Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1Mx1Mx400Micron, Finished With 12Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement Rounding The Edge Sand Making And Finishing The Outlet Complete. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion.(I) Single Socketed Pipes.110 Mm Diameter , (101) Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion. (101.I) Coupler 110 Mm , Single Tee With Door 110X110X110 Mm , Bend 87.5° 110 Mm Bend , Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50X50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete 110 Mm , Providing And Fixing Rectangular High Density Polyethylene Water Storage Loft Tank With Cover, Conforming To Isi : 12701, Colour Of Opaque White Or As Approved By Engineer-In-Charge. The Rate Includes Making Necessary Holes For Inlet, Outlet & Over Flow Pipes. The Base Support Including Fittings & Fixtures For Tank Shall Be Paid Separately. , (104) Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge Internal Work - Exposed On Wall (104..I) 15 Mm Nominal Dia Pipes , 20 Mm Nominal Dia Pipes , 25 Mm Nominal Dia Pipes , (105) Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. (105.I) 15 Mm Nominal Dia Pipes , (105.Ii) 20 Mm Nominal Dia Pipes , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :Range Of Three Urinal Basins With 10 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible 40 Mm Dia , Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms , Providing And Fixing Ptmt Shelf 440 Mm Long, 124 Mm Width And 36 Mm Height Of Approved Quality And Colour, Weighing Not Less Than 300 Gms , (114) Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) : (114.I) 25 Mm Nominal Bore , (114.Ii) 20 Mm Nominal Bore , (115) Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : (115.I) 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length 15 Mm Nominal Bore , (117) Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) (117.I) 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Ptmt Stop Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 86Mm Long. Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt, Push Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 98Mm Long. Weighing Not Less Than 75 Gms. , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 : 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15Mm Nominal Bore , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement : 6 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix 1:4 (1Cement: 4 Fine Sand). , 6 Mm Cement Plaster Of Mix : 1:3 (1 Cement: 3 Fine Sand) , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour :New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) , Glassfibre Reinforced Concrete For Cladding And Jali (Polished And Machine Cut) Of Thickness 12 Mm For Wall Lining (Veneer Work) Backing Filled With A Grout Of 12Mm Thick Average In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Marble Dust) With An Admixture Of Pigment To Match The Granite Shade (To To Be Secured To The Backing By Means Of Fastners Which Shall Be Paid For Seprately). Granite Flamed Finish Of Any Colour And Shade Area Of Slab Above 0.50 Sqm , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sqm. Mm F.R. L.S. Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet Suitable Size ;M.S. Box And Earthing The Point With 1.5 Sq.Mm Fr L.S. Pvc Insulated Copper Conductor Single Core Cable As Required (Group C). , Wiring For Circuit/Sub Main Wiring Along With Earth Wire With The Following Sizes Of Fr L.S. Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Steel Conduit As Required. A) 2X2.5 Sq.Mm + 1X2.5 Sq. Mm Earth Wire. , B) 2X6 Sq. Mm + 1X6 Sq. Mm Earth Wire , Wiring For Light /Power Plug With 2X4 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit Along With 1 No. 4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Supplying And Fixing Metal Box Of 150Mm X75Mmx60 Mm Deep (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 3 Pin 5/6 & 15/16 Amps Socket Outlet And 5/6 Amps Piano Type Switch, Connection, Painting Etc. As Required For Light Plugs To Be Used In Non Residential Building. , Earthing With G.I. Earth Pipe 4.5 Metre Long 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/Coke And Salt As Required. , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Single Pole & Neutral , Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. 200 Mm X 250 Mm X 60 Mm Deep , Supplying & Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts On Surface/Recess, Complete With Tinned Copper Bus Bar, Earth Bus Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Power Painted Including Earthing Etc. As Required (But Without Mcb/Rccb/Isolator) 12 Way, Double Door.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
20.
Defence #9835139 AOC
Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.
Contract Date: Mar 17, 2026 Contract Value : 59.85 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
21.
Housing Urban and Rular Development #9786076 Price Bid
Tender For Mow/Deposit Work Under Jail-3 Sub Dn, Pwd Bhopal-1 1.2 Transportation by manual labour including loading, unloading and stacking for lead up to 50 metre. 1.2.1 Lime, moorum, building rubbish 1.2.2 Earth 1.2.3 Manure or sludge 1.2.4 Excavated rock 1.2.5 Sand, stone aggregate below 40mm nominal size 1.2.6 Stone aggregate 40mm nominal size and above 1.2.7 Stone soling 1.2.8 Bricks 1.2.9 S.W. Pipes 1.2.9.1 100 mm dia 1.2.9.2 150 mm dia 1.2.9.3 200 mm dia 1.2.9.4 250 mm dia 1.2.9.5 300 mm dia 1.2.9.6 350 mm dia 1.2.9.7 400 mm dia 1.2.9.8 450 mm dia 1.2.9.9 500 mm dia 1.2.9.10 600 mm dia 1.2.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and reinforced cement pipes 1.2.10.1 100 mm dia 1.2.10.2 125 mm dia 1.2.10.3 150 mm dia 1.2.10.4 200 mm dia 1.2.10.5 250 mm dia 1.2.10.6 300 mm dia 1.2.10.7 350 mm dia 1.2.10.8 400 mm dia 1.2.10.9 450 and 500 mm dia 1.2.10.10 600, 700, 750 and 800 mm dia 2 1.3 Add extra for every additional lead of 50 metre or part thereof. 1.3.1 Lime, moorum, building rubbish 1.3.2 Earth 1.3.3 Manure or sludge 1.3.4 Excavated rock 1.3.5 Sand, stone aggregate below 40mm nominal size 1.3.6 Stone aggregate 40mm nominal size and above 1.3.7 Stone soling 1.3.8 Bricks 1.3.9 S.W. Pipes 1.3.9.1 100 mm dia 1.3.9.2 150 mm dia 1.3.9.3 200 mm dia 1.3.9.4 250 mm dia 1.3.9.5 300 mm dia 1.3.9.6 350 mm dia 1.3.9.7 400 mm dia 1.3.9.8 450 mm dia 1.3.9.9 500 mm dia 1.3.9.10 600 mm dia 1.3.10 R.C.C. pipes, Steel cylinder, R.C. pipes, C.I. pipes, and unreinforced cement pipes 1.3.10.1 100 mm dia 1.3.10.2 125 mm dia 1.3.10.3 150 mm dia 1.3.10.4 200 mm dia 1.3.10.5 250 mm dia 1.3.10.6 300 mm dia 1.3.10.7 350 mm dia 1.3.10.8 400 mm dia 1.3.10.9 450 and 500 mm dia 1.3.10.10 600, 700, 750 and 800 mm dia 3 2.1 Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. in all kinds of soil. 2 2.2 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 5 2.3 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 6 2.4 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material. 2.4.1 beyond 30 cm girth up to and including 60 cm girth 2.4.2 beyond 60 cm girth up to and including 120 cm girth 2.4.3 beyond 120 cm girth up to and including 240 cm girth 2.4.4 above 240 cm girth 7 2.5 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil 8 2.6 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil 9 2.7 Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. 2.7.1 Ordinary rock 2.7.2 Hard rock (requiring blasting) 2.7.3 Hard rock (blasting prohibited) 10 2.8 Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means)Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-InCharge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day 2.8.1 Ordinary rock 2.8.2 Hard rock (requiring blasting) 2.8.3 Hard rock (blasting prohibited) 11 2.9 Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil 2.9.1 Pipes, cables etc., not exceeding 80 mm dia. 2.9.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.9.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. 12 2.10 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). 13 2.11 Extra for excavating trenches for pipes, cables, etc., in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 14 2.12 Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth up to 1.5 m including including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : 2.12.1 Ordinary rock : 2.12.1.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 2.12.1.3 Pipes, cables exceeding 300 mm dia but not exceeding 600mm dia 2.12.2 Hard rock (requiring blasting) 2.12.2.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.2.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.2.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia 2.12.3 Hard rock (blasting prohibited) 2.12.3.1 Pipes, cables etc. not exceeding 80 mm dia. 2.12.3.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2.12.3.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600mm dia. 15 2.13 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 16 2.14 Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 3m in depth but not exceeding 4.5 m. (Rate is over corresponding basic item for depth up to 1.5 metre.) 17 2.15 Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). 2.15.1 Depth not exceeding 1.5 m. 2.15.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.15.3 Depth exceeding 3 m but not exceeding 4.5 m. 18 2.16 Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). 2.16.1 Depth not exceeding 1.5 m. 2.16.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.16.3 Depth exceeding 3 m but not exceeding 4.5 m. 19 2.17 Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered) : 2.17.1 Depth not exceeding 1.5 m. 2.17.2 Depth exceeding 1.5 m but not exceeding 3 m. 2.17.3 Depth exceeding 3 m but not exceeding 4.5 m. 20 2.18 Extra for planking, strutting and packing materials for cavities (in close timbering) if required to be leftpermanently in position. (Face area of timber permanently left to be measured). 21 2.23 Extra rates for quantities of works, executed: 2.23.1 In or under water and/or liquid mud, including pumping out water as required. 2.23.2 In or under foul position, including pumping out water as required. Note: - The extra percentage rate is applicable in respect of each item but limited to quantity executed in difficult conditions. The depth shall be reckoned correct to 0.1 metre. 0.05 metre or more shall be taken as 0.1 metre and less than 0.05 metre ignored. 22 2.24 Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 23 2.25 Extra for every additional lift of 1.5 m or part thereof in excavation. (No extra lift is payable if work is done by mechanical means) 2.25.1 All kinds of soil. 2.25.2 Ordinary or hard rock. 24 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. 25 2.27 Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. 26 2.28 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then refiling the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc., disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5m. 2.28.1 All kinds of soil. 2.28.2 Ordinary rock 2.28.3 Hard rock (requiring blasting) 2.28.4 Hard rock (blasting prohibited) 27 2.29 Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) 28 2.30 Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.30.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. 29 2.31 Deduct for disposed soil not levelled and neatly dressed. 30 2.32 Preconstruction antitermite treatment to the building under construction by providing.Stage 1: Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. 31 2.33 Making bore holes for providing dowel bars at designed depth in rock foundation by drilling 40 mm dia bore hole in rock including necessary bending hooking, in position and grouting with cement slurry etc. complete as per drawing and specification. (Steel to be paid separately). 32 2.34 Excavation in soil using hydraulic excavator and including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- section, and transporting to the appropriate ground contour, location and levelling and dressing earth neatly with all lifts and lead upto 1000 metre. 33 2.35 Earth work in rough excavation by any means and bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne in embankments for roads, flood banks, marginal bank and guide bank of filling up ground depression within campus, lead upto 50m and all lift. All kinds of soil. 34 2.36 Bankingfilling excavated earth in layers not exceeding 20cm in depth, breaking clods, watering rolling each layer with 1/2 tonne roller or wooden or steel rammers etc. and rolling every 3rd and top-must layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal bank and guide bank etc. lead upto 50m and lift upto 1.5m. All kinds of soil. 35 2.37 Deduct for not rolling with power roller of minimum 8 tonnes for bankingfilling excavated earth in layers not exceeding 20cm in depth. 36 2.38 Deduct for not watering with the excavated earth for bankingfilling 37 2.39 Providing and laying of permanent piping technology anti-termite treatment before flooring work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6.4 mm I.D.with inbuilt pressure compensation chip at every 30 cm interval in the tube,. The contractor shall submit approved line plan for piping system and junction boxes dully approved by Engineer-in- charge with bond of 5 year warranty. 2.39.1 Permanent piping system with Junction boxes 2.39.2 Anti-termite chemical injected area 38 2.40 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (All kinds of soil) 39 3.1 Cement mortar 1:1 (1 cement: 1 sand) 40 3.2 Cement mortar 1:2 (1 cement: 2 sand). 41 3.3 Cement mortar 1:3 (1 cement: 3 sand). 42 3.4 Cement mortar 1:4 (1 cement: 4 sand). 43 3.5 Cement mortar 1:5 (1 cement: 5 sand). 44 3.6 Cement mortar 1:6 (1 cement: 6 sand). 45 3.7 Cement mortar 1:2 (1 cement: 2 stone dust). 46 3.8 Cement mortar 1:2 (1 cement: 2 marble dust). 47 3.9 White cement mortar 1:2 (1 white cement: 2 marble dust). 48 3.10 Cement mortar 1:5 (1 cement: 5 marble dust). 49 3.11 White cement mortar 1:3 (1 white cement: 3 marble dust). 50 3.12 White cement mortar 1:5 (1 white cement: 5 marble dust). 51 3.13 Mortar in lime , surkhi (50% red and 50% light yellow) and marble dust 1:1.5:0.5 52 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete 4.1.1.2 M-20 – Grade concrete 4.1.1.3 M-15 – Grade concrete 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate 4.1.3 With fly ash. 4.1.3.1 1:2:3½:9 (1 ordinary Portland cement : 2 Fly ash : 3½ sand: 9 graded stone aggregate 40 mm nominal size) 4.1.3.2 1:2½:4:11 (1 ordinary Portland cement : 2½ fly ash : 4 sand : 11 graded stone aggregate 40 mm nominal size) Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 53 4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete 4.2.1.2 M 20 – Grade concrete 4.2.1.3 M 15 – Grade concrete 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 54 4.3 Centering and shuttering including strutting, propping etc. and removal of form work for : 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. 4.3.3 Above plinth: Columns, pillars, posts and struts. 55 4.4 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing . 4.4.1 M-15 (With 20mm nominal size graded stone aggregate) 4.4.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 56 4.5 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement morta1:3 (1 cement : 3 sand) on exposed surfaces complete.(With 20mm nominal size graded stone aggregate) 57 4.6 Providing and fixing upto floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 sand) on exposed surfaces complete. 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 58 4.7 Providing and fixing upto floor two level precast cement concrete solid block including hoisting and setting in position with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete : 4.7.1 M-15 (With 20mm nominal size graded stone aggregate) 4.7.2 M-10 (M 10) (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate 59 4.8 Providing and Fixing upto floor two level pre cast concrete hollow block including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 sand) on exposed surfaces complete. 4.8.1 M-15 (With 20mm nominal size graded stone aggregate) 4.8.2 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. 60 4.9 Add extra for item no. 4.6, 4.7 and 4.8 above floor two level for every additional floor or part there of 61 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). 62 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size). 63 4.12 Extra for providing and mixing water proofing material as per IS standard in cement concrete work quantity as prescribed by the manufacturer. 64 4.13 Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 65 4.14 Extra for concrete work in superstructure above floor two level for each floors or part thereof 66 4.15 Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.Note for item No. 4.15:- The quantity will be calculated by multiplying. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored. 67 4.16 Extra for laying concrete in or under foul positions. 68 4.17 Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) 69 4.18 Extra for addition of synthetic polyester triangular fiber of length 12 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/ Water retaining structures by using 125 gms of synthetic polyester triangular fibre for 50 kgs cement used as per directions of Engineer-in- Charge. 70 4.19 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. 71 4.20 Providing and fixing up to floor two level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 72 4.21 Providing and fixing up to floor two level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete . 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 73 4.22 Providing and fixing up to floor two level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) 74 4.23 Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.Note : (1) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacemen to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC. 4.23.1 All works up to plinth level: 4.23.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.23.2 All works above plinth and upto floor two level 4.23.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.23.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.23.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 75 4.24 Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in- charge. 4.24.1 All works up to plinth level: 4.24.1.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.1.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.1.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 4.24.2 All works above plinth and upto floor two level 4.24.2.1 M-20 grade plain cement concrete (cement content considered @ 280 kg/cum) 4.24.2.2 M-15 grade plain cement concrete (cement content considered @ 240 kg/cum) 4.24.2.3 M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) 76 4.25 Plum Cement concrete 1:2:4 with 75% graded metal of maximum size 40 mm and 25% plum of 150mm size. 77 4.26 Providing and laying cement concrete in Sunken floors of WC, Toilet, Wash Area, etc with 1:5:10 (1 cement : 5 coarse sand (zone-3) : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering 78 5.1 Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 M-20 Grade Concrete 5.1.2 M-15 Grade Concrete 79 5.2 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: 5.2.1 M-20 Grade Concrete 80 5.3 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. 5.3.1 M-20 Grade Concrete 81 5.4 Providing and laying upto floor two level reinforced cement concrete (with20 mm nominal size graded stone aggregate) in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with Concrete grade. 5.4.1 M-20 Grade Concrete 82 5.5 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in arches, archribs, domes, vaults, shells, folded plate above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in Concrete grade. 5.5.1 M-20 Grade Concrete 83 5.6 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in chimneys, shafts, upto floor two level excluding the cost of centring, shuttering, finishing and reinforcement with 5.6.1 M-20 Grade Concrete 88 5.7 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in well-steining excluding the cost of centering, shuttering, finishing and reinforcement with 5.7.1 M-20 Grade Concrete 84 5.8 Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in vertical and horizontal fins individually or forming box louvers, facias and eaves boards up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in M 20 –Grade Concrete 85 5.9 Centering and shuttering in cluding strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. 5.9.2.2 Above plinth upto 3.6 m height from plinth level 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. 5.9.3 Suspended floors, roofs, landings, balconies and access platform. 5.9.4 Shelves(Cast in situ) 5.9.5 Lintels, beams, girders, bressumers and cantilevers 5.9.6 Columns, P i l l a r s , Piers, Abutments, Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. 5.9.8 Spiral staircases (including landing). 5.9.9 Arches, domes,vaults upto 6m span 5.9.10 Extra for arches, domes, vaults exceeding 6 m span 5.9.11 Chimneys and shafts 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. 5.9.13 Well steining 5.9.14 Vertical and horizontal fins individually or forming Box louvers band, facias and eaves boards. 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. 5.9.17 Cornices and mouldings 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of S.E. in case of B & R works and from Additional Project Director in case of PIU works) 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of S.E. in case of B&R works and from Additional Project Director in case of PIU works) 86 5.10 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof (Plan area to be measured) 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 87 5.11 Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in lintels, manhole cover, shelves and like including setting in cement mortar 1:3 (1 cement : 3 sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with M 15 –Grade Concrete. 88 5.12 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 sand) etc. complete excluding plastering of the jambs, sills and soffits. 5.12.1 50 mm thick 5.12.2 40 mm thick 5.12.3 25 mm thick 89 5.13 Encasing rolled steel sections, in beams and columns, with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) including centering and shuttering complete but excluding cost of reinforcement. 80 5.14 Encasing rolled steel section in grillages with cement concrete M 15 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including centering and shuttering but excluding cost of expanded metal and hangers. 91 5.15 Extra for providing and fixing expanded metal mesh of size 20x60mm and strands 3.25mm wide 1.6mm thick weighing 3.64 kg per sqm for encasing of rolled steel sections in beams, columns and grillages excluding cost of hangers. 92 5.16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) 5.16.1 Mild steel and Medium Tensile steel bars. 5.16.2 Hard drawn steel wire 5.16.3 Cold twisted bars (CTD) 5.16.4 Hot rolled deformed bars 5.16.5 Hard drawn steel wire fabric 5.16.6 Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 93 5.17 Add extra for providing reinforcement above Floor two level for every additional floor or part thereof. 94 5.18 Providing and fixing in position copper plate as per design for expansion joints. 95 5.19 Providing and filling in position, blown bitumen in expansion joints. 96 5.20 Providing and filling in position bitumen mix filler of Proportion 80 kg. Of hot bitumen, 1 kg. Of cement and 0.25 cubic metre of sand for expansion joints. 97 5.21 Providing and filling gap in expansion joint between RCC/ Stone/Ceramic tiles/Granite/ Marble by providing silicon sealant over backer rod of approved quality weather sealant as per drawing and direction of engineer in charge up to 25mm width & 12 mm depth. 98 5.22 Providing and fixing in position bitumen impregnated fibre board conforming to IS: 1838 including cost of primer, sealing compound in expansion joints. 5. 22.1 12 mm thick 5. 22.2 25 mm thick 5. 22.3 50 mm thick 99 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. 5. 23.1.2 200mm wide. 5. 23.1.3 250mm wide. 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. 5. 23.2.2 200 mm wide. 5. 23.2.3 250 mm wide. 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. 5. 23.3.2 200 mm wide. 5. 23.3.3 250 mm wide. 100 5.24 Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 101 5.25 Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.Note- For Item No. 5.25:-The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under sub – soil water condition 102 5.26 Extra for laying reinforced cement concrete in or under foul positions. 103 5.27 Providing and laying in position machine batched, machine mixed cement concrete (BMC) of M-25 grade for reinforced cement concrete work using cement content as per approved mix design concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 330 kg/cum) and no extra payment for extra cement used as per mix design. 5.27.1 All works upto plinth level. 5.27.2 All works above plinth level and upto floor five level. 5.27.3 Add extra for each floor for all works above floor five level. 104 5.28 Extra for providing richer mixes of BMC design mix as per item no 5.27 upto plinth level and at all floor levels. (No extra payment for using extra cement as per requirement of mix design.) 5. 28.1 Providing M-25 grade concrete instead of M- 20 grade.(Note : minimum cement content is @ 330 kg/cum) 5. 28.2 Providing M-30 grade concrete instead of M- 25 grade.(Note : minimum cement content is @ 340 kg/cum) 5. 28.3 Providing M-35 grade concrete instead of M- 25 grade.(Note: : minimum cement content is @ 350 kg/cum) 5. 28.4 Providing M-40 grade concrete instead of M- 25 grade.(Note: minimum cement content is @ 360 kg/cum) 105 5.29 Providing and placing in position precast reinforced cement concrete waffle units square or rectangular as per design and shape for floors and roofs in M-20 –Grade Concrete (with graded stone aggregate 10mm nominal size. including provision of steel hooks for lifting and form work, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement. 106 5.30 Providing and laying in position ready mixed concrete (RMC) of M-25 grade for reinforced cement concrete work, using cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.Note: Minimum cement content is @ 330 kg/cum. (No extra payment for using extra cement as per requirement of mix design.) 5.30.1 All works upto plinth level. 5.30.2 All works above plinth level and upto floor V level. 5.30.3 Extra for each additional floor for all works above floor five level 107 5.31 Extra for R.C.C. work above floor two level for each floors or part thereof. (except items 5.27 and 5.30) 108 5.32 Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. 5.32.1 Non pigmented wet curing compound 5.32.2 Pigmented wet curing compound. 109 5.33 Providing and fixing in position factory made precast RCC M-40 doors, windows and ventilator frames having excellent smooth finish, as per IS: 6523 with 6mm dia main reinforcement each polymer block having at least four holes for passing one or adjacent rebates to hold fast grill or steel bar, ventilator frame provided with grooves for louvers at an angel of 45 degree at spacing to block direct vision etc. complete, as per the direction of Engineer-in-charge. The cost of hold fast and cement concrete block of 1:3: 6 (1 Cement: 3 sand: 6 Graded stone aggregate 20mm nominal size) mix is also included in the item. 5. 33.1. Frame 125 mmx 60 mm (double rebate) 5. 33.2. Frame 100mmx 60 mm (Single rebate) 5. 33.3 Frame 85mmx 60 mm (Single rebate) 110 5.34 Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 sand). 111 5.35 Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non- staining, with less than 1 percent water absorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 5. 35.1 12 mm thick 5. 35.2 25 mm thick. 5. 35.3 50 mm thick. 112 5.36 Providing and sealing the retaining wall expansion Joints with anodized aluminum extruded section of 135 mm × 3.1 mm confirm to alloy of 6063 T5/T6including fixing of an imported EPDM moisture Barrier conform to (American Society for Testing and Materials) 2240 & ASTM - G53 & 84 fixing with Epoxy adhesive confirm to ASTM C-881 complete in all respect as per manufacturer Drawing and specifications. With 5 year guarantee. 113 5.37 Providing and fixing sheet covering over expansion joints with iron screws as per design. Non- asbestos cement bonded particle board 6 mm thick as IS: 14276 5.37.1 150mm wide 5.37.2 200mm wide 5.37.3 250mm wide 114 5.38 Providing & laying in position Prestressing steel strands (low relaxation) on hollow core bed by using mechanical pulling arrangement like Rabbit/ Bed master including all accessories for Stressing &destressing operations as per approved make conforming to IS1343 & grade FY-1860 etc, complete as per drawings and direction of Engineer -in- charge. 115 5.39 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In- Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer - inCharge. (Material shall confirm to ASTM 6063). 5. 39.1 Floor Joint of 100 mm gap 5. 39.2 Floor Joint of 150 mm gap 5. 39.3 Floor Joint of 200 mm gap 116 5.40 Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 5. 40.1 Wall Joint of 100 mm gap 5. 40.2 Wall Joint of 150 mm gap 5. 40.3 Wall Joint of 200 mm gap 117 5.41 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centeringarragement support plates asper ASTM B221-02. . The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) 5.41.1 Roof Joint for 100 mm gap 5.41.2 Roof Joint for 150 mm gap 5.41.3 Roof Joint for 200 mm gap 118 5.42 Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100gm/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) 119 6.1 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not less than 40kg /cm2 and water absorption not more than 15% in foundation and plinth i/c curing etc. complete. 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) 120 6.2 Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process ,crushing strength not less than 40kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level i/c curing etc. complete. 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) 121 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). 122 6.4 Brick work with well burnt chimney bricks in bulls pattern trench kiln, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). 123 6.5 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). 124 6.6 Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) 125 6.7 Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) 126 6.8 Brick work with calcium silicate bricks machine moulded conforming to IS:4139, having 100 kg/cm2 average compressive strength in super structure above plinth level upto floor II level in : 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) 127 6.9 Brick work with extruded burnt fly ash clay sewer bricks (Conforming to IS: 4885 ) in foundation and plinth : Cement Mortar 1:4 ( 1 cement : 4 sand) 128 6.10 Brick work with extruded burnt fly ash clay sewer bricks (conforming to IS: 4885) in archesin foundation and plinth including centering and shuttering complete in cement mortar 1:3 (1 cement: 3 sand). 129 6.11 Extra for brick work in superstructure above floor two levels for each additional floor or part thereof respective item. 130 6.12 Providing half brick masonry with well burnt chimney bricks in bull patent trench kiln manufactured by ghol process crushing strength not less than 40 kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level. 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) 131 6.13 Providing half brick masonry with well burnt chimney bricks in bull pattern trench kiln crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level. 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) 132 6.14 Providing half brick masonry with well burnt open bhatta bricks crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) 133 6.15 Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) 134 6.16 Extra for half brick masonry in superstructure, above floor two level for every floor or part thereof respective item. 135 6.17 Extra for providing and placing in position 2 Nos. 8mm dia. M.S. bars at every third course of in half brick masonry. 136 6.18 Honey-comb brick work 10 cm thick with well burnt chimney bricks manufactured by ghol process crushing strength not less than 40kg /sqcm and water absorption not more than 15% in cement mortar 1:4 (1 cement : 4 sand). 137 6.19 Extra for forming cavity 5cm to 7.5cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. Ties 300mm long of 25x3mm section at not less than 3 ties per sqm as per approved design 138 6.20 Brick work in plain arches in superstructure including centering and shuttering complete with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 cement : 3 sand). 139 6.21 Brick work in gauged arches in superstructure in cement mortar 1:3 (1 cement : 3 sand) including centering and shuttering complete, with chimney bricks having crushing strength not less than 40kg /cm2 and water absorption not more than 15% 140 6.22 Providing half brick masonry with kiln burnt clay bricks of 40kg /cm2 and water absorption not more than 15% in cement mortar 1:3 (1 Cement : 3 sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10 cm wide bitumen felt type 3 grade 1. 141 6.23 Extra for laying brick work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of brick work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 142 6.24 Extra for laying brick work in or under foul position. 143 6.25 Providing and laying cellular concrete blocks masonry having density ranging from 800kg/m3 in super structure above plinth level up to floor two level in cement mortar 1:4 (1 cement: 4 sand) The nominal dimensions of the concrete blocks shall be as follows in additional block shall be of half lengths of 200, 250 or 300 mm to correspond to the full lengths. The size of the blocks specified other than those specified may also be used. 144 6.26 Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry, using AAC blocks (Size length 300, 400, 500, 600 mm Height 200, 250, 300 mm Width 100, 150, 200, 250 mm) conforming to IS 2185 PART 3, having compressive strength not less than 4 MPa (Grade II) in super structure, blocks jointed with approved block laying polymer modified adhesive mortar as per ASTM international standard including raking out joints. Vertical bands shall be placed along jams (vertical member of chowkhats) and extend upto lintel levels to arrest cracking at corner openings. RCC bands shall be measured with AAC block masonry. Rates include all materials including steel bars, wastages, scaffolding and all labour etc. complete. 6.26.1 AAC Masonry in polymer modified mortar 145 6.27 Extra for AAC masonry work in superstructure above floor two level for each additional floor or part thereof 146 6.28 Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced roof slabs, lintels and chhajjas as per IS: 6073 -2006 grade D specifications (dry density, without steel, 550 kg/m3 to 650 kg/m3 and minimum compressive strength 3.5 N/mm2) reinforcement steel provided inside AAC slab, lintel and chhajja shall be ascertained on the basis of manufacturer’s certificate and also by random destructive testing done by engineer-in-charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Deflection & ultimate load test for AAC reinforced roof slab and lintel shall be as per annex. B of IS: 6073 -2006 and criteria for conformity and sampling shall be as per clause-13 of IS: 6073 -2006. 147 6.29 Precast autoclaved aerated concrete (AAC) reinforced wall panels:- Providing hoisting & fixing precast Autoclaved Aerated Concrete (AAC) reinforced wall panels as per IS:6072 -1972 grade D (dry density, without steel, 550 kg/m3 to 650 kg/m3 and inside AAC panels. Quantity of reinforcement steel in AAC panels shall be ascertained on the basis of certificate of the manufacturer and also by random destructive testing by engineer-in- charge or his representative for which cost of samples and testing charges shall be borne by the contractor. Cost of reinforcement inside AAC panels shall be paid separately. 148 6.30 Add extra for AAC wall panels, roof slabs, lintels and chhajjas above floor two level for each additional floor as per item no 6.29 and 6.30. 149 6.32 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 6.32.1 From ground level upto plinth level 6.32.2 Above plinth level upto floor II level 150 6.33 Brick work with modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete from ground level up to plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) 6.33.1 From ground level upto plinth level 6.33.2 Above plinth level upto floor II level 151 6.34 Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturer’s specifications in superstructure above plinth level up to floor two level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2 152 6.35 Extra for Gypsum panel Partitions in superstructure above floor two level for every four floors or part thereof. 153 7.1 Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 sand) 154 7.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor two level, including leveling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. 7.2.1 Cement mortar 1:6 (1cement: 6 sand). 155 7.3 Extra for random rubble masonry with hard stone in superstructure above floor two level for every floors or part thereof 156 7.4 Extra for random rubble masonry with hard stone in : 7.4.1 Square or rectangular pillars 7.4.2 Circular pillars. 157 7.5 Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. 158 7.6 Coursed rubble masonry (1st or 2nd sort) with hard stone in foundation and plinth. 7.6.1 Cement mortar 1:6 (1 cement : 6 sand) 7.6.2 Cement mortar 1:6 (1 cement : 6 sand) 159 7.7 Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor two level. 7.7.1 Masonry work (first sort) in cement mortar 1:6 (1 cement : 6 sand) 7.7.2 Masonry work (second sort) , in cement mortar 1:6 (1 cement : 6 sand) 160 7.8 Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above floor two level for every floors or part thereof 161 7.9 Extra for coursed rubble masonry with hard stone (first or second sort) in : 7.9.1 Square or rectangular pillars 7.9.2 Circular pillars. 7.9.3 Extra for coursed rubble masonry with hard stone (first or second sort) curved on plan for a mean radius not exceeding 6 m. 162 7.10 Stone work in plain ashlar masonry in super structure upto floor two level in cement mortar 1:6 (1 cement : 6 sand) including pointing with cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the sand stone shade : 7.10.1 One face dressed. 7.10.1.1 Red sand stone 7.10.1.2 White sand stone 7.10.2 Both face dressed. 7.10.2.1 Red sand stone. 7.11.2.2 White sand stone 163 7.11 Stone work plain ashlar masonry in arches in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.11.1 One face dressed. 7.11.1.1 Red sand stone 7.11.1.2 White sand stone 7.11.2 Both face dressed. 7.11.2.1 Red sand stone. 7.11.2.2 White sand stone 164 7.12 Stone work plain ashlar masonry in domes, in super structure upto floor two level in cement mortar 1:3 (1 cement: 3 sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.12.1 One face dressed 7.12.1.1 Red sand stone 7.12.1.2 White sand stone 7.12.2 Both face dressed. 7.12.2.1 Red sand stone. 7.12.2.2 White sand stone. 165 7.13 Stone work ashlar masonry punched (ordinary) in superstructure above plinth level and upto floor two level in cement mortar 1:6 (1 white cement: 6 sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the sand stone shade. 7.13.1 Red sand stone one face punched. 7.13.2 Red sand stone both face punched 7.13.3 White sand stone one face punched. 7.13.4 White sand stone double face punched 166 7.14 Extra for stone work, plain ashlar or ashlar punched above floor two level for every floor or part thereof. 167 7.15 Extra for plain ashlar or ashlar punched in : 7.15.1 Square or rectangular pillars 168 7.16 Extra for stone work; plain ashlar or ashlar punched in curved on plan with a mean radius not exceeding 6 m. 169 7.17 Extra for additional cost of centering for arches exceeding 6m span including all strutting, bolting, wedging etc. And removal (area of soffit to be measured). 170 7.18 Stone work sunk or moulded or sunk and moulded upto floor Two level in cement mortar 1:6 (1cement : 6 sand) including pointing with white cement mortar 1:2 (1 white : 2 marble dust) with an admixture of pigment matching the stone shade : 7.18.1 Red sand stone 7.18.2 White sand stone 171 7.19 Extra for stone work sunk or moulded or sunk and moulded or carved in : 7.19.1 Triangular or Square or rectangular pillars 7.19.2 Circular or polygonal pillars 172 7.20 Extra for stone work sunk or moulded in cornices. 173 7.21 Stone work (machine cut edges) for wall lining etc. (veneer work) up to 10 meter height backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of clamps which shall be paid for separately): 7.21.1 Red sand stone - exposed face fine dressed with rough backing. 7.21.1.1 70 mm thick. 7.21.1.2 60 mm thick. 7.21.1.3 50 mm thick 7.21.1.4 40 mm thick. 7.21.1.5 30 mm thick. 7.21.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.2.1 70 mm thick. 7.21.2.2 60 mm thick. 7.21.2.3 50 mm thick 7.21.2.4 40 mm thick. 7.21.2.5 30 mm thick. 7.21.3 White sand stone - exposed face fine dressed with rough backing. 7.21.3.1 70 mm thick. 7.21.3.2 60 mm thick. 7.21.3.3 50 mm thick 7.21.3.4 40 mm thick. 7.21.3.5 30 mm thick. 7.21.4 White sand stone - Exposed face machine cut and table rubbed with rough backing. 7.21.4.1 70 mm thick. 7.21.4.2 60 mm thick. 7.21.4.3 50 mm thick 7.21.4.4 40 mm thick. 7.21.4.5 30 mm thick. 174 7.22 Extra for stone work (veneer work) curved on plan with a mean radius not exceeding 6 m. 175 7.23 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement :2 sand) including making the necessary chases in stone and holes in walls wherever required. 176 7.24 Providing and fixing stone dowels of size 10x5x2.5cm cut to double wedge shape as per design in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases 177 7.25 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 sand) including making the necessary chases. 178 7.26 Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1:4 (1 cement : 4 sand) including pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment matching the stone shade: 7.26.1 Red sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 7.26.2 White sand stone: With common burnt clay bricks of 25 kg/cm2 compressive strength. 179 7.27 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 sand) including pointing in white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment matching the stone shade: 7.27.1 Red sand stone 7.27.2 White sand stone 180 7.28 30mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement: 4 sand) including finishing complete. 181 7.29 Providing and fixing red sand stone brackets 55x22.5x45cm sunk and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6mm 30 cm long and dowel bars 7.5 cm long 6 mm dia as per design. 182 7.30 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 7.30.1 Red sand stone 7.30.2 White sand stone 183 7.31 Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1cement :3 sand) including pointing in white cement mortar 1:2 (1white cement: 2stone dust) with an admixture of pigment , matching the stone shade, jali slab without any chamfers etc. 7.31.1 Red sand stone 7.31.2 White sand stone 184 7.32 Extra for laying stone work in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete.NOTE: - The quantity will be calculated by multiplying the depth measured from sub - soil water level up to the centre of gravity of stone work in cum executed under the sub - soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. 185 7.33 Extra for laying stone work in or under foul position. 186 7.34 Wall lining butch work upto 10m height with red/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width 75mm thick strips i/c 12mm thick bed of cement mortar 1:3 (1 Cement : 3 sand) i/c ruled pointing in cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in- charge. 187 7.35 Stone work ( machine cut edges) for wall lining upto 10 m height etc. (Veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 Cement : 3 sand) and jointed with Cement mortar 1:2 (1 cement : 2 marble dust) including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid for separately) 7.35.1 25mm thick Kota stone slabs exposed face dressed and rubbed. 7.35.2 25mm thick Dholpur stone slabs exposed face dressed and rubbed. 7.35.3 20 to 25mm thick kota stone slabs exposed slab not dressed and rubbed. 7.35.4 20 to 25mm thick Dholpur stone/shivpuri stone not dressed and rubbed. 188 7.36 Stone tile work with 8mm thick mirror polished and machine cut edge for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sand), including pointing in white cement with an admixture of pigment to match the stone shade. 7.36.1 Granite stone of any colour and shade 7.36.2 Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble 189 7.37 Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 190 7.38 Providing and fixing dry stone cladding upto 10 metre height with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and/ or with the help of cramps, pins etc. And sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins. shall be paid for separately.) 7.38.1 Red sand stone. 7.38.2 White sand stone 191 7.39 Providing and fixing structural steel frame (for dry stone cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/rectangular tube in the required pattern as per architectural drawing including including drilling necessary steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution).The frame work shall be fixed in true horizontal and vertical lines/ planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel clamps shall be paid for separately and nothing extra shall be paid.) 192 7.40 Providing and fixing adjustable stainless steel clamps of approved quality and of required shape and size adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding fixed on frame 193 8.1 Providing and supplying aluminium extruded tubular and other aluminium sections frame work as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coated of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). 194 8.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of aluminium structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels.. (A) Structural analysis anddesign and preparation of shopdrawings for the specified designloads conforming to IS 875 partIII (the system must passed theproof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sectionsBfor fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals,microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage andprotection against fire hazard including (B) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. toaccommodate 3 Dimentional movement for achieving perfect verticality and fixing structuralglazing system rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contactswith nuts and washers etc. of stainless steel grade 316, of the required capacity and in requirednumbers.(C) Providing and filling, two part pump filled, structural silicone sealant and one partweather silicone sealant compatible with the structural silicone sealant of required bitesize in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(D) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick andof sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight(E) Making provision for drainage of moisture/ water that enters the curtain glazing systemto make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary 195 8.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.8.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. 196 8.4 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 197 8.5 Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi - rigid, inorganic, non- combustible fibre glass wool insulation 50 mm thick having density 48 kg/m3, conforming to IS: 8183 and BS: 3958 Part 5.The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non- woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm/sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. 198 8.6 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., included in cost of relevent Item). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 199 8.7 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (ACP) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places. 8.7.1 4 mm thick alumminium composite pannel material consisting of 3 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.5mm thick) 8.7.2 4 mm thick alumminium composite pannel material consisting of 3.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 8.7.3 3 mm thick alumminium composite pannel material consisting of 2.5 mm thick FR grade mineral core sandwiched between two alumminium sheets (each 0.25mm thick) 200 8.8 Design, supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as pr IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete.For the purpose of payment actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured., 201 8.9 Providing and fixing aluminium magnesium alloy (FACADE) wall cladding system consisting of panels 200mm wide x 17mm deep x 0.5mm thick of maximum length of 6.0 mtr. coil coated on a continuous paint line double baked and roll formed from centre to centre at a distance of maximum 1.20 mtr. The stringer shall be fixed to a suitable rigid structure. All panels shall be achromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and the other side (inner side) with a primer coat on a continuous paint line, and fixed as per the direction of the Engineer-in-Charge. 202 8.10 Providing and fixing Aluminium Magnesium alloy Plain Panel Sun Louvres of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length upto 6 mtrs coil coated on a continuos paint line double baked between metal and paint, enamelled twice under high temperature one side with full primer and finish, the other side (inner side) with a primer coat and Skin Coat on a Continuos Paint Line.Note: - 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. upto two decimal places. 203 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood 9.1.2 Sal wood 9.1.3 Kiln Head wood seasoned and chemically treated hard wood (Haldu, Kail, Bija wood.) 9.1.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 9.1.4.1 Frame of size 100mmX60mm single or double rebate 9.1.4.2 Frame of size 120mmX60mm double rebate. 205 9.2 Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001(Part-B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixing in position with hold fast lugs or with dash fasteners of required dia and length ( hold fast lugs or dash fastener shall be paid for separately). 206 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position ( with necessary stainless steel screw) 9.3.1 Sal wood 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 207 9.4 Extra for additional labour wood work in circular shape, such as in frames of fan light : 9.4.1 Second class teak wood 9.4.2 Sal wood 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. 208 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws excluding, panelling/glazing which will be paid for separately, all complete as per direction of Engineer-in-charge. 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters 9.5.1.2 30 mm thick shutters 9.5.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. 9.5.2.1 35 mm thick shutters 9.5.2.2 30 mm thick shutters 9.5.3 Kiln seasoned selected planks of sheesham wood. 9.5.3.1 35 mm thick shutters 9.5.3.2 30 mm thick shutters 9.5.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood shutters 9.5.4.1 35 mm thick 9.5.4.2 30 mm thick 209 9.6 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 9.6.1 Second class teak wood 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum 210 9.7 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer-in- charge and panelling with panels of: 9.7.1 12mm thick plain grade - 1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT - I IS : 3087 marked bonded with BWP type synthetic resin adhesive as per IS : 848 : 9.7.2 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre- lamination conforming to IS : 12823 Grade 1, Type - II marked: 9.7.3 12 mm thick one side pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and prelamination conforming to IS : 12823 Grade -1, Type II marked: 211 9.8 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.8.1 Second class teak wood 9.8.1.1 35 mm thick 9.8.1.2 30 mm thick 9.8.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood 9.8.2.1 35 mm thick 9.8.2.2 30 mm thick 9.8.3 Kiln seasoned selected planks of sheesham wood. 9.8.3.1 35 mm thick 9.8.3.2 30 mm thick 9.8.4 Factory made Kiln seasoned chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood 9. 8.4.1 30 mm thick shutters 9. 8.4.2 35 mm thick shutters 212 9.9 Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B) , using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked fixing with M.S. pressed butt hinges bright finished of required size with necessary screws as per directions of Engineer-in- charge. 30 mm thick shutters. 213 9.10 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 9.10.1 5 mm thick instead of 4 mm thick. 9.10.2 10 to 12 mm float glass 9.10.3 5.5 mm safety glass 9.10.4 10-12mm safety glass 214 9.11 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 215 9.12 Deduct for providing pin headed glass panes instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory windows, shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). 216 9.13 Extra for S.S, hinges providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). 217 9.14 Deduct for not providing hinges in doors, windows or clerestory window shutters with : 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. 218 9.15 Providing and fixing 25 mm thick Second class teak wood shutters using 4mm float glass for cup board etc. : 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. 9.15.2. 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 219 9.16 Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) : 9.16.1 12 mm thick 9.16.2 18 mm thick 220 9.17 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 9.17.1 18 mm thick 9.17.2 25 mm thick 221 9.18 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. 222 9.19 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. 223 9.20 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only. 224 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 225 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. 9.22.2 Circular. 226 9.23 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). 227 9.24 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 228 9.25 Providing and fixing wire gauze shutters using galvanised M.S. wire gauze of average width of aperture 1.4mm in both direction with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws: 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.1.3 Kiln seasoned selected class of sheesham wood. 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.2.3 Kiln seasoned selected class of sheesham wood. 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.3.3 Kiln seasoned selected class of sheesham wood. 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.25.4.3 Kiln seasoned selected class of sheesham wood. 229 9.26 Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, and as per TADS 15 :2001 (Part B) using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568 for doors, windows and clerestory windows including ISI marked M.S. pressed fixing with butt hinges bright finished of required size with necessary screws as per directions of Engineer-in-charge: 9.26.1 35 mm thick shutters 9.26.2 30 mm thick shutters 230 9.27 Providing 50x50x50mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 sand) and making good the walls etc. 231 9.28 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 9.28.1 25 mm long 9.28.2 32 mm long 9.28.3 40 mm long 9.28.4 50 mm long 9.28.5 60 mm long 232 9.29 Providing and fixing 2nd class teak wood plain lining tongued and grooved including wooden plugs complete with necessary screws and priming coat on unexposed surface. 9.29.1 40 mm thick. 9.29.2 25 mm thick. 9.29.3 20 mm thick 9.29.4 12 mm thick 233 9.30 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre- laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 9.30.1 12 mm thick 9.30.2 18 mm thick 9.30.3 25 mm thick 234 9.31 Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 235 9.32 Providing and fixing plywood 4 mm thick one side decorative veneer conforming to IS: 1328 (type-1) for plain lining / cladding with necessary screws, priming coat on unexposed surface with: Decorative veneer facings of approved manufacture. 236 9.33 Providing and fixing 4mm thick coir veneer board, ISI marked IS: 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. 237 9.34 Providing and fixing skirting of Pre- laminated with (one side decorative and other side balancing lamination) flat pressed, 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : 9.34.1 18 mm thick 9.34.2 25 mm thick 238 9.35 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 9.35.1 2nd class teak wood 9.35.1.1 50x12 mm 9.35.1.2 50 x 20 mm 9.35.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.35.2.1 50x12 mm 9.35.2.2 50x20 mm 239 9.36 Providing and fixing plain jaffri of 35x10 mm laths placed 35 mm apart (frames to be paid separately) including fixing 50x12 mm beading complete with : Second class teak wood. 240 9.37 Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked,, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 241 9.38 Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842, including top cover of 6 mm coir veneer board, nickle plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with Haldu, Kail, Bija wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. 242 9.39 Extra for using veneered particle board conforming to IS 3097 Grade I, in item of pelmet 18mm thick 150mm wide. 9.39.1 Non decorative veneer on both sides. 9.39.2 Particle board with decorative veneering on both sides. 243 9.40 Providing and fixing teak wood lipping of size 25x3 mm in pelmet. 244 9.41 Providing and fixing of 1.25 mm thick chromium plated brass plate, with two chromium plated curtain rods brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 9.41.1 12 mm dia. 9.41.2 20 mm dia. 9.41.3 25 mm dia. 245 9.42 Providing and fixing nickel plated curtain rods M.S. pipe with nickel plated brackets : 9.42.1 20 mm dia (heavy type) 9.42.2 25 mm dia (heavy type) 246 9.43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.43.1 Fixed to steel windows by welding. 9.43.2 Fixed to openings /wooden frames with rawl plugs screws etc. 247 9.44 Providing and fixing expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick for windows etc. including 62 x19 mm beading of II nd class teak wood and priming coat with approved steel primer all complete. 248 9.45 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 249 9.46 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete. 9.46.1 With 2nd class teak wood beading 62x19 mm. 9.46.2 With 12 mm mild steel U beading. 250 9.47 Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. per sqm in panelled and glazed door and window shutter instead of glass sheet 4 mm thick. 251 9.48 Providing 40x5 mm flat (iron hold fast 40 cm long) (0.628 kg) including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) 252 9.49 Providing wooden beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : 9.49.1 Sal wood. 9.49.2 Haldu, Kail, Bija wood. 253 9.50 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 9.50.1 125x65x2.12 mm 9.50.2 100x58x1.90 mm 9.50.3 75x47x1.70 mm 9.50.4 50x37x1.50 mm 254 9.51 Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete : 9.51.1 125x90x4.00 mm 9.51.2 100x75x3.50 mm 9.51.3 75x60x3.10 mm 9.51.4 50x40x2.50 mm 255 9.52 Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 9.52.1 125x65x2.12 mm 9.52.2 100x58x1.90 mm 9.52.3 75x47x1.70 mm 9.52.4 50x37x1.50 mm 256 9.53 Providing and fixing ISI marked oxidised M.S. pressed Parliamentary hinges with necessary screws etc. complete : 9.53.1 150x125x27x2.80 mm 9.53.2 125x125x27x2.80 mm 9.53.3 100x125x27x2.80 mm 9.53.4 75x100x20x2.24 mm 257 9.54 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : 9.54.1 150 mm 9.54.2 125 mm 9.54.3 100 mm 258 9.55 Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 9.55.1 150 mm 9.55.2 125 mm 9.55.3 100 mm 259 9.56 Providing M.S. Piano hinges ISI marked IS: 3818 finished with nickel plating and fixing with necessary screws etc., complete. 9.56.1 Overall width 35 mm. 9.56.2 Overall width 50 mm. 9.56.3 Overall width 65 mm. 260 9.57 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 9.57.1 300x16 mm 9.57.2 250x16 mm 261 9.58 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.58.1 250x10 mm 9.58.2 200x10 mm 9.58.3 150x10 mm 9.58.4 100x10 mm 262 9.59 Providing and fixing ISI marked 85x42mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete 263 9.60 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete : 9.60.1 300x20x6 mm 9.60.2 250x20x6 mm 264 9.61 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.61.1 125 mm 9.61.2 100 mm 9.61.3 75 mm 265 9.62 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 9.62.1 150 mm 9.62.2 115 mm 9.62.3 90 mm 266 9.63 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 9.63.1 300 mm weighing not less than 200 gms. 9.63.2 250 mm weighing not less than 150 gms. 9.63.3 200 mm weighing not less than 120 gms. 267 9.64 Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors. (Weighing not less than 450 gms.) 268 9.65 Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 9.65.1 300x16 mm 9.65.2 250x16 mm 269 9.66 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.66.1 250x10 mm 9.66.2 200x10 mm 9.66.3 150x10 mm 9.66.4 100x10 mm 270 9.67 Providing and fixing ISI marked 85x42mm stainless steel pull bolt lock with necessary screws bolts, nut and washers etc. complete. 271 9.68 Providing and fixing ISI marked stainless steel door latches with screws etc. complete : 9.68.1 300x20x6 mm 9.68.2 250x20x6 mm 272 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 9.69.1 125 mm 9.69.2 100 mm 9.69.3 75 mm 273 9.70 Providing and fixing stainless steel hasp and staple (safety type) conforming to IS specification with necessary screws etc. complete : 9.70.1 150 mm 9.70.2 115 mm 9.70.3 90 mm 274 9.71 Providing and fixing stainless steel casement stays (straight peg type) conforming to IS specification with necessary screws etc. complete. 9.71.1 300 mm weighing not less than 200 gms. 9.71.2 250 mm weighing not less than 150 gms. 9.71.3 200 mm weighing not less than 120 gms. 275 9.72 Providing and fixing stainless steel safety chain with necessary fixtures for doors. Conforming to IS specification (Weighing not less than 450 gms.) 276 9.73 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 9.73.1 125x64x1.90 mm 9.73.2 100X58X1.90 mm 9.73.3 75x47x1.80 mm 9.73.4 50x37x1.50 mm 277 9.74 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.74.1 125x64x2.50 mm 9.74.2 100x60x2.50 mm 9.74.3 75x50x2.50 mm 278 9.75 Providing and fixing 50 mm Stainless steel cup board or wardrobe knob with necessary screws (best make of approved quality) 279 9.76 Providing and fixing Stainless steel hanging type floor door stopper with necessary screws, etc. complete. 280 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) 9.77.2 125x70x4 mm (ordinary type) 9.77.3 100x85x5.5 mm (heavy type) 9.77.4 100x70x4 mm (ordinary type) 9.77.5 75x65x4 mm (heavy type) 9.77.6 75x40x2.5 mm (ordinary type) 9.77.7 50x40x2.5 mm (ordinary type) 281 9.78 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 9.78.1 150x125x27x5 mm 9.78.2 125x125x27x5 mm 9.78.3 100x125x27x5 mm 9.78.4 75x100x20x3.2 mm 282 9.79 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.79.1 400x10 mm 9.79.2 250x10 mm 9.79.3 200x10 mm 9.79.4 150x10 mm 9.79.5 100x10 mm 283 9.80 Providing and fixing bright finished brass door latch with necessary screws etc. complete. 9.80.1 300x16x5 mm 9.80.2 250x16x5 mm 284 9.81 Providing and fixing bright finished brass handles with necessary screws etc. complete. 9.81.1 125 mm 9.81.2 100 mm 9.81.3 75 mm 285 9.82 Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete. 9.82.1 300x16mm 9.82.2 250x16mm 286 9.83 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 287 9.84 Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). 288 9.85 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 289 9.86 Providing and fixing bright finished brass night latch including necessary screws etc. complete (best make of approved quality). 290 9.87 Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) : 9.87.1 40 mm 9.87.2 50 mm 9.87.3 65 mm 9.87.4 75 mm 291 9.88 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best make of approved quality) 292 9.89 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 293 9.90 Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. 294 9.91 Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 9.91.1 300 mm weighing not less than 330 gms 9.91.2 250 mm weighing not less than 280 gms 9.91.3 200 mm weighing not less than 240 gms 295 9.92 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete: 9.92.1 150 mm 9.92.2 115 mm 9.92.3 90 mm 296 9.93 Providing and fixing Cromium plated brass hanging type floor door stopper with necessary screws, etc. complete. 297 9.94 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. 298 9.95 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. 299 9.96 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 300 9.97 Providing and fixing chromium plated brass 100 mm mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). 301 9.98 Providing and fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). 302 9.99 Providing and fixing special quality chromium plated brass cupboard locks with six levers including necessary screws etc. complete (Best make of approved quality) of : 9.99.1 Size 40 mm 9.99.2 Size 50 mm 9.99.3 Size 65 mm 9.99.4 Size 75 mm 303 9.100 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. 304 9.101 Providing and fixing chromium plated brass sliding door bolts ISI marked with nuts and screws etc complete. 9.101.1 300x16mm 9.101.2 250x16mm 305 9.102 Providing and fixing chromium plated brass tower bolts ISI marked with nuts and screws etc complete. 9.102.1 400X10mm 9.102.2 300x10mm 9.102.3 250x10mm 9.102.4 200x10 mm 9.102.5 150x10 mm 9.102.6 100x10 mm 306 9.103 Providing and fixing chromium plated brass door latch ISI marked with necessary screws etc complete. 9.103.1 300x16x5mm 9.103.2 250x16x5mm 307 9.104 Providing and fixing chromium plated brass night latch ISI marked with necessary screws etc complete. 308 9.105 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 9.105.1 125 mm 9.105.2 100 mm 9.105.3 75 mm 309 9.106 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. 310 9.107 Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete : 9.107.1 300 mm weighing not less than 330 gms 9.107.2 250 mm weighing not less than 280 gms 9.107.3 200 mm weighing not less than 240 gms 311 9.108 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Note:- Aluminum hinges shall not be used in wooden shutters. 9.108.1 125x75x4 mm 9.108.2 125x63x4 mm 9.108.3 100x75x4 mm 9.108.4 100x63x4 mm 9.108.5 100x63x3.2 mm 9.108.6 75x63x4 mm 9.108.7 75x63x3.2 mm 9.108.8 75x45x3.2 mm 312 9.109 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 9.109.1 300x16 mm 9.109.2 250x16 mm 313 9.110 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.110.1 400X10mm 9.110.2 300x10 mm 9.110.3 250x10 mm 9.110.4 200x10 mm 9.110.5 150x10 mm 9.110.6 100x10 mm 314 9.111 Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. complete. 315 9.112 Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 316 9.113 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 9.113.1 125 mm 9.113.2 100 mm 9.113.3 75 mm 317 9.114 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.114.1 Single rubber stopper 9.114.2 Twin rubber stopper 318 9.115 Providing and fixing aluminium casement window stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 319 9.116 Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. 320 9.117 Providing and fixing aluminum U beading of required size to Pre-laminated /flush door shutter including fixing etc. complete as per direction of Engineer-in-charge. 321 9.118 Providing and fixing PTMT handles with necessary screws etc. complete. 9.118.1 125x34x24 mm weighing not less than 23 gms. 9.118.2 150x34x24 mm weighing not less than 26 gms. 322 9.119 Providing and fixing PTMT Butt hinges with necessary screws etc. complete. 9.119.1 75x60x10 mm fitted with 5.5 mm dia M.S. Bright Bar Rod weighing not less than 34 gms. 9.119.2 100x75x10 mm fitted with 5.5 mm dia MS Bright Bar Rod weighing not less than 53 gms. 323 9.120 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete. 9.120.1 152x42x18 mm weighing not less than 60 gms. 9.120.2 202x42x18 mm weighing not less than 78 gms. 324 9.121 Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. 325 9.122 Providing and fixing PTMT hanging type floor door stoper with necessary screws etc complete. 326 9.123 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: 9.123.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.1.1 Second class teak wood. 9.123.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.1.3 Kiln seasoned selected class of sheesham wood. 9.123.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.2.1 Second class teak wood. 9.123.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.2.3 Kiln seasoned selected class of sheesham wood. 9.123.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.123.3.1 Second class teak wood. 9.123.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.3.3 Kiln seasoned selected class of sheesham wood. 9.123.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.123.4.1 Second class teak wood. 9.123.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. 9.123.4.3 Kiln seasoned selected class of sheesham wood. 327 9.124 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 9.124.1 With 2nd class teak wood beading 62x19 mm. 9.124.2 With 12 mm mild steel U beading. 328 9.125 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of Haldu, Kail, Bija wood in scantling of section 50x25mm fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. 329 9.126 Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50mm (base and height). 330 9.127 Providing and fixing 2nd class teak wood lipping/ moulded beading or Taj beading of size 18x5mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer- in-charge. 331 9.128 Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 332 9.129 Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete (Best make of approved quality). 9.129.1 Triple strip vertical type. 9.129.2 Double strip (horizontal type). 333 9.130 Providing and fixing magic eye in door shutters including fixing. Complete (Best make of approved quality). 334 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long 9.131.2 450mm long 9.131.3 500mm long 335 9.132 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by P/F stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) 336 9.133 Providing and fixing 12mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40mm thick. 9.133.1 Marine plywood conforming to IS: 710 9.133.2 Fire retardant plywood conforming to IS: 5509. 337 9.134 Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 9.134.1 1.5 mm thick. 9.134.2 1.0 mm thick. 338 9.135 Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge. 339 9.136 Providing and fixing cup board shutters with 25mm thick veneered particle board IS : 3097 marked exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in- Charge. 9.136.1 With decorative veneering on one side and commercial veneering on other side. 9.136.2 With non decorative veneering on both sides. 340 9.137 Providing and fixing factory made shutters of 25 mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium U type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of U beading and hinges will be paid for separately). 341 9.138 Providing and fixing in wall lining MDF board medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 9.138.1 12 mm thick. 9.138.2 18 mm thick. 9.138.3 25 mm thick. 342 9.139 Providing and fixing 25mm thick pre- laminated medium density fibre board exterior grade(Grade-I) IS:14587:1998 marked one side decorative to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickeled plated bright finishing M.S. piano hinges IS:3818 marked with necessary screwed complete 343 9.140 Providing and fixing skirting with Pre- laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand complete. 9.140.1 18 mm thick 9.140.2 25 mm thick 344 9.141 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corner (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete. 9.141.1 75mm overall thickness partition with 12.5 mm thick double skin fire rated glass reinforced gypsum (GRG) plaster board conforming to IS: 2095: part 3 1996 Board with BIS certification marks. 9.141.2 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS:2095: part I 1996 Board with BIS certification marks. 9.141.3 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./sq.cm. 9.141.4 66mm overall thickness partition using 8mm thick double skin non- asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre cement screw. 9.141.5 68mm overall thickness partition using 9mm thick Heavy Duty Fibre Cement Board double skin non asbestos, reinforced with cellulose fibre,manufactured through autoclaving proces(High presssure steam cured)Type A, Category 4 conforming to IS 14862:2000. (for wet areas) 9.141.6 70 mm overall thickness Partition using 10mm thick double skin non-asbestost multipurpose termite, fire & moisure resistance (acoustic 30db) cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 345 9.142 Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the W profile (0.55mm thick ) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55 mm, placed @ 610mm C/C with fully threaded self- tapping dry wall screws. Board is fixed to the W profile with 25 mm countersunk ribbed head screws @ 200mm C/C., all complete as per the drawing and directions of engineer-in-charge the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. 9.142.1 10 mm thick tapered edge calcium silicate board made with calcareous and siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure, with compressive strength 225 kg/sq.cm, Bending strength 100 kg/sq.cm. 9.142.2 12 mm thick Gypsum board conforming to IS: 2095 Part-I. 9.142.3 8 mm thick non-asbestost multipurpose termite, fire & moisure resistance cement bonded particle board as per IS: 14276 with suitable cement bonded board screw. 9.142.4 8mm Both side Factory Prelamianted cement bonded particle board as per IS: 15786. 9.142.5 9mm thick non asbestos,heavy duty fibre cement board reinforced with cellulose fibre manufactured through autoclaving process(High pressure steam cured) Type A,Category 4, conforming to IS 14862. 346 9.143 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically and horizontally ) including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer- in-charge. 347 9.144 Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587 348 9.145 Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). 9.145.1 Board 12 mm thick 9.145.2 Board 18 mm thick 349 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick 9.146.2 25 mm thick 350 9.147 Providing and Installation of acoustical wall panelling fabric finish hardened square edge, FR grade fabric (colour as approved by Egnineer in charge) wrapped soft fibre core (glass fibre) panel having metal framing, of size 600x2100x25mm having density 100-120Kgs/ m3, weight 3.0kg/m2 NRC up to 0.9 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work with the points extending outward. Then panels shall positioned and pressed into place. 351 9.148 Providing and installation of acoustical wall panelling wood finish Slats made out of HDF board , Melamine / veneer laminated finish, perforated wooden grooved slats (2mm grooves @ 8mm centers) / (2mm Slats @16mm pitch) / (2mm grooves @ 32mm centers) / (2mm grooves @ 64mm centers), Aluminium core cross channel having thickness 0.5mm, length 2400mm, web 15mm and 27mm, depth 18mm and flanges of 7mm with suitable edge and centre brackets is then fixed perpendicular to the cross channel with the help of fasteners at every 400mm centers. Contractor to Provide expansion joints of 3mm at every 5mts bothways. 352 9.149 Providing and installation of paintble acoustic wall panelling consisting of strand kerfed edge paint finished as approved by Engineer in charge. magnesite bonded wood fiber panels of size 600x2400x20mm having density 400kg/m3, weight 8- 20kg/m2 which is fixed to GI strut system. fastened to wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channel at 600mm centers. The Kerfed edge panels shall be then inserted into the H-spline against wall to perfect fit. 9.149.1 Wt. 8.20 kg/m2 9.149.2 Wt. 4.2 kg/m2 353 9.150 Providing and fixing plain lining with necessary screws/nuts and bolts/ nails including a coat of approved primer on one face and fixed on wooden /steel frame work complete as per direction of Engineer-incharge. (Frame work shall be paid forseparately) 9.150.1 12mm thick commercial ply conforming to IS: 1328 BWR type. 9.150.2 18mm thick commercial ply conforming to IS: 1328 BWR type. 354 9.151 Providing and Installation of acoustic wall panelling consisting of Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x2400x20mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI strut system. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers. Kerfed edge Fabric wrapped panels shall be then inserted into the H-spline against wall to perfect fit. 355 9.152 Providing and Installation of acoustic wall panelling consisting of Soak Cord of selected colours as approved by Engineer in charge, square edge Fabric wrapped wood fiber panels of size 600x1200x10mm having density 400Kgs/m3, weight 4- 20kg/m2 installed by using GI struts,Z bars. GI Z bars having 40mm height, thickness 1.2mm is first fixed behind the panels by identifying resin spots by using suitable fasteners.Clean exposed surfaces of wall and ensure walls are in plumb line before installing on wall (provide necessary packing shims if required). Soak cord square edge panels shall be slided into the Z bars fixed on wall. 356 9.153 Providing and installation of acoustic wall panelling consisting of Stretch NRC by using FR Grade NRC fabric of size 1700mm width, shall be stretched by using wooden base 10mm thick, rigid vinyl Stretch Tracks half wrap/ full wrap 25mm and Midseam 300mm centers. The fabric is stuck on the Align Tape (by removing the protective cover) at the same time as being stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module width would be 1600mm. 357 9.154 Providing and Installation of wall panelling consisting of Square edge Magnesia core panels of size 1100x2400x8mmmm having density 1000kgs/m3, weight 8kg/m2 installed by using GI Strut system. The GI struct system includes Cross channel having thickness 0.45mm, length 3600mm, knurled web 40, depth 10mm and equal flanges of 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. The panels to be fixed on the cross channel with suitable fasteners. 358 9.155 Supplying and installation of magnesia block 66 mm thick drywall partition including Framework includes Floor/ Head GI channels having thickness 0.5mm, length 3600mm, equal flanges of 32mm and web of 50mm fixed to floor and ceiling with suitable fasteners at 300mm centers staggered. Second layer of magenesia oxide block 8mm thick should be fixed other side of the frame work similar fashion as the first layer. 3mm gap should be maintained between boards.3 mm gap shall be filled with jointing compound. Magnesia oxide block shall have following physical charecterstics. 9.155.1 Using 8mm thick magnesia block 9.155.2 Using10mm thick magnesia block 9.155.3 Using12mm thick magnesia block 9.155.4 Using12mm thick magnesia block 359 9.156 Add extra for providing and fixing Thermal insulation by providing 50mm thick synth PF having dencity 1000 GSM within the cavity held in position by using chicken wire mesh/ cross bracing/ pasting to the wall. 360 9.157 Providing and laying Gypsum panel partitions 100mm thick with water proof Gypsum panels of size 666x500x100mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor II level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2. 361 9.158 Providing and fixing factory made UPVC door frame made of UPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frame reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge: 9.158.1 Extruded section Profile size 48x40 mm. 9.158.2 Extruded section Profile size 42x50 mm. 362 9.159 Providing and fixing Panelled UPVC door shutter to existing door frames. 24 mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). 363 9.160 Providing and fixing UPVC panelled door shutter UPVC 30 mm thick factory made PVC or UPVC door shutter made of styles and rails of a UPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge. 364 9.161 Providing and fixing 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mmx25mm or less as per requirement with an average wall thickness of 1mm (± 0.3mm). PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. The Top and Bottom edges of the shutter are covered with an end-cap of the size 25mmx11mm. Door shutter shall be reinforced with special polymeric reinforcements as per required specification and direction of Engineer-in- charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. 365 9.162 Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100mmx37mm with wall thickness 2mm (±0.2mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos. of plastic brackets of size 100mmx37mm, wall thickness 2mm (+0.2mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100mmx20 mm, and inserting 2 nos. tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-charge. 366 9.163 Providing and Fixing, factory made, PVC door frame made of PVC extruded sections of size 75mmx53 mm, having wall thickness 2.0mm (±0.2mm). Both verticals sides of the frame reinforced with PVC profile of cross section size 28mm x 30mm x2mm thickness (± 0.2 mm) and 75mmx200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut jointed and fusion welded together, including providing and fixing 3 nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos. and sizes of anchor dash fastener, all complete as per manufacturers specification and direction of engineer-in-charge. 367 9.164 Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115mm x 37mm with wall thickness , panels of 100 x 20 mm printed and laminated and inserting 2 nos. 6 mm dia. bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturers specification and direction of Engineer-in-Charge. 368 9.165 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturers specification and direction of Engineer-in- Charge. 369 9.166 Providing and fixing factory made 30 mm thick PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall have a coat of steel primers and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification and drawing. 9.166.1 Plain PVC door shutters. 9.166.2 Pre laminated PVC door shutters. 370 9.167 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. 371 9.168 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles and rails shall be of size 75 mmx30 mm having wall thickness 5 mm. The styles, top and bottom rails shall have one side wall thickness of 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. 9.168.2 Decorative finish (both side wood grained finish). 372 9.169 Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) 9.169.1 Single rebate (75 mm X 50 mm) 9.169.2 Single rebate (100 mm X50 mm) 9.169.3 Single or double rebate (125 mm X 65 mm) 373 9.170 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter 374 9.171 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 9.171.1 30 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 9.171.2 35 mm thick WPC (Wood Polymer Composite) solid decorative type flush door shutter 375 9.172 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 9.172.1 18 mm thick 9.172.2 25 mm thick 376 9.173 Providing and fixing factory made single extruded WPC (Wood polymer composite solid plain white color board for backing of cupboards and bathrooms/ kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-in-Charge. (Note: stainless steel screws shall be paid separately) 9.173.1 6 mm thick 9.173.2 12 mm thick 377 9.174 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 378 9.175 Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5 mm (±0.2 mm) made out of single piece extruded PVC profile, with mitred cut joints and joint with 2nos of PVC bracket of size 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100mm long anchor fasteners complete, all as per manufacturer’s specification and direction of Engineer -in- charge. 379 9.176 35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded soild PVC profiles, 5mm (±0.2mm) thick, having styles and rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm solid core in middle of rail section integrally extruded, fixing the styles and rails with the help of solvent and self driven self tapping screws of 125 mm x11 mm, including providing 5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturers specification and direction of Engineer-in- charge. 9.176.1 Non decorative finish (matt finish). 9.176.2 Decorative finish (wood grained finish). 380 9.177 Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. 381 9.178 Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat .Doorframe laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibreglass from all sides. MS stat shall be provided 382 9.179 Providing and fixing to existing door frames. 30 mm thick glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames. 383 9.180 Providing and fixing door frame FRP 30mm thick fiberglass reinforced Plastic (F.R.P.) flush door shutter in different plain and wood inish made with fire retardant grade unsaturated polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 384 9.181 Providing and fixing factory made Fibreglass Reinforced plastics (F.R.P.) chajja 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather and sunlight. 385 9.182 Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in- charge (Dash fastener to be paid for separately). 386 9.183 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II) tested and certified as per laboratory approved by Engineer-in-charge with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). 387 9.184 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc. complete all as per direction of Engineer- in-charge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance. 388 9.185 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch and Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. 389 9.186 Providing and Fixing factory made UPVC door frame made of UPVC exturded sections, of size 65 mmx55 mm with wall thickness 2.0 mm (±0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mmx30 mm having wall thickness 2 mm (±0.2mm), including providing and fixing 3 nos. of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number and size of anchor dash fastners, all complete as per manufacturers specification and direction of Engineer-in-charge. 390 9.187 Providing and Fixing, UPVC factory made, white colour casement/sliding window and door made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8 mmx100 mm long fasteners, all complete as per direction of Engineer-in-charge. (Glazing, hardware hinges and fitting etc. to be paid separately.) 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) 9.187.1.5 Glazing bead (12mm x 18mm) 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) 9.187.2.3 Casement Glazing bead (35mm x 18 mm) 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) 9.187.3.2 Sliding window Sash (60mm x 44mm) 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) 9.187.4.2 Sliding Door Sash (80mm x 44mm) 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) 391 9.188 Providing and fixing stainless steel (SS- 304 grade) friction hinges to the side/ top hung UPVC windows, of approved quality with necessary stainless steel screws etc. as per direction of Engineer-in-charge. 9.188.1 200 x 19 x 1.9 mm 9.188.2 250 x 19 x 1.9 mm 9.188.3 300 x 19 x 1.9 mm 9.188.4 350 x 19 x 1.9 mm 9.188.5 400 x 19 x 1.9 mm 392 9.189 Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete. 393 9.190 Providing and fixing zinc alloyed (white powder coated) touch lock for UPVC sliding window with necessary screws etc. complete. 394 9.191 Providing and fixing steel roller for UPVC sliding window with necessary screws etc. complete. 395 9.192 Providing and fixing steel roller for UPVC sliding door with necessary screws etc. complete. 396 9.193 Providing and fixing steel (white powder coated) crescent lock for UPVC sliding window/ door with necessary screws etc. complete. 397 9.194 Providing and fixing factory made UPVC white colour casement/casement cum fixed glazed windows comprising of UPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For UPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion 67 x 80 all having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) 398 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic capsof approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) 399 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). 400 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) 401 9.198 Providing and fixing factory made UPVC white colour sliding glazed window above 1.50 m in height dimension comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: - For UPVC frame, sash and mullion extruede profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). 402 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section madAfter fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: - For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 10.00 sqm). 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 8.00 sqm upto10.00 sqm). 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 403 9.200 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture PVC beading as gap insert below top and bottom rail joined together using solvent cement adhesive. An additional 5mm thick Prelaminated PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ channel using PVC solvent cement adhesive etc. complete as per direction of Engineer-in- charge. Manufacturer’s specification and drawing. 30 mm thick pre laminated PVC door shutters. 404 9.201 Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet (Single Extruded) with density not less than 600 kg/cum, conforming to IS: 2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO : 9001 -2000 certified company. 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter 405 9.202 Providing and fixing factory made pre laminated solid PVC flush door shutters 28 to 30 mm thick made from co-extruded three layer rigid PVC foam sheet with density not less than 600 kg/cum, conforming to IS: 2380 part 14, for screw holding strength and outer layers laminated on both sides by laminated sheet with density not less than 1400 kg/cum, lamination shall be at the manufacturing process itself and manufactured by an ISO: 9001-2000 certified company. 9.202.1 1mm thick laminated sheet 9.202.2 0.12 mm thick laminated sheet 406 9.203 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) laminated type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens with well matched 3mm thick commercial 3ply veneering consisting of vertical grains, cross bands withing frame of door/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS: 2202. The rate shall be inclusive of all material and labour complete and as per specification and dirction of Engineer-in-Charge. 9.203.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.2 35mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.203.3 25mm thick (for cupboard) including 3 nos. 75mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 407 9.204 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) non decorative type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens (strips) and frame of kiln seasoned and chemically treated, finger jointed cross bands including all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50cm. Each shutter shall be factory made to the exact opening size within frame of doors/cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and confirmity with IS:2202. 9.204.1 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary. 9.204.2 30mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 9.204.3 25mm thick including 3 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. 408 9.205 Deduct for not providing 2nd class teak wood batten lipping in factory made shutters i.e. item no 9.203 and 9.204. 409 9.206 Providing & fixing acrylic solid surface in thickness 4/6/12 mm of approved colour made out of non-porous surfacing material homogeneously composed of ± 1/3 acrylic resin (also known as PolyMethyl Methacrylate -PMMA), and ± 2/3 NO extra shall be paid for joint adhesive, silicon or related accessories and for transportation. Item should cover 5 years, commercial warranty of product as per FCWS norms. The product should be UV protected for exterior applications & LGA hyginene tested anti bacterial for health care application areas. Area of application are Table Tops, Exterior facade cladding, health care areas like modular operation theater hospital scrubs, wash basins, partition & paneling, laboratory commercial show room, hotels, office & residential areas. 9.206.1 Acrylic Solid Surface sheet – Glacier white designer white 9.206.1.1 6 mm thick sheet 9.206.1.2 12 mm thick sheet 9.206.2 Acrylic Solid Surface sheet - Any Solid colours/Hospital use Medi Blue 9.206.2.1 6 mm thick sheet 9.206.2.2 12 mm thick sheet 9.206.3 Acrylic Solid Surface sheet - Any other 9.206.3.1 6 mm thick sheet 9.206.3.2 12 mm thick sheet 410 9.207 Providing and fixing of 8 mm thick non asbestos multipurpose board reinforced with cellulose fibers for wall cladding will consist of following operations:1. Fixing of a layer of 6mm Moisture/fire Resistance Heavy Duty fibre cement Boards over above mentioned 6 mm heavy duty fibre cement board with the help of 25mm self drilling, self tapping Fibre Cement screws @ 300mm c/c. All external corners are to be protected with the use of suitable corner profile of GI or PVC. All above operation is to be done in order and as directed by Engineer-in-Charge.(frame work to be paid separately). 411 9.208 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS: 15380(2003), eco-friendly, termite resistant, borer free, anti warping phenol formaldehyde (PF), decorative designe moulded or rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company’ gujcon, century, green shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.208.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.208.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 412 9.209 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), non decorative designe moulded and labor complete as per specifications and direction of engineer-in- charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.209.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.209.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws 9.209.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. piano hinges with screws. 413 9.210 Providing and fixing IS marked factory made High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), 2 and 4 Panel designe moulded or plain construction with particle board shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.210.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.210.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 414 9.211 HDF decorative prelaminated pine wood panel door with glass / wiremash:- Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.211.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.211.2 30 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 415 9.212 Providing and fixing IS marked factory made veneer High Density Fibre (HDF) flush door shutters conformity to IS:15380(2003), eco-friendly, termite resistant borer free, anti warping phenol formaldehyde (PF), . The rate shall be inclusive of all material and labour complete as per specifications and direction of engineer-in-charge. Material supply company shall be registered by Bureau of Indian Standards, Member of Indian Green Building Council, ISO 9001, ISO 14001 (Environment management system), National small industries corporation(NSIC), SME Rating Agency of Indian Ltd.(SMERA), Dun and Bradstreet (D&B). 9.212.1 35 mm thick including 4 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.2 32 mm thick including 3 nos 100 mm long ISI marked heavy weight (2.5 mm thick) Stainless Steel butt hinges with necessary screws. 9.212.3 25 mm thick ISI marked heavy weight nickel plated bright finished M.S. Piano hinges with screws. 416 9.213 Non Decorative Pine Wood Flush Door:- Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer- in-charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202 9.213.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.213.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 417 9.214 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned sheet shall be as per IS: 2046 type S of approved quality. Each shutter shall be factory made to the exact size (opening) within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in- charge. 9.214.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.214.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 418 9.215 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) laminated type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) and frame of kiln seasoned within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. The rate shall be inclusive of all material and labour complete and as per specification and direction of engineer-in-charge. 9.215.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.215.3 25mm thick (for cupboard) including 3 nos. 75 mm long ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 419 9.216 Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202 (Part I) veneer decorative type, core of block board construction with kiln seasoned and chemically treated 1st class pine wood battens (strips) s and commercial grade face veneers on both outer faces of shutters including kiln seasoned and chemically treated, finger jointed all material and labour complete as per specification and direction of engineer-in- charge. Spacing of finger joints in wood as above shall not be less than 50 cm. Each shutter shall be factory made to the exact opening size within frame of doors/ cupboards and shall be stamped by the manufacturer to display name of manufacturer, batch number of product and conformity with IS:2202. 9.216.1 35 mm thick including 4 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.2 30 mm thick including 3 nos. 100 mm long, ISI marked heavy weight (2.5mm thick) Stainless Steel butt hinges with necessary screws. 9.216.3 25mm thick (for cupboard) including 3 nos. 75 mm long, ISI marked heavy weight (2.5mm thick) nickel plated bright finished M.S. piano hinges with necessary screws. 420 9.217 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides,made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastne with necesary stainless steel screws, all complete as per direction of Engineer-in-charge. 421 9.218 Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity.Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. 422 10.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 423 10.2 Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 424 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. 425 10.4 Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S.gusset plates at the junction and corners 25mm dia pulley,40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer. 426 10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6mm for diagonal braces 10.5.2 Using flats 30x6mm for diagonal braces and central cross piece. 427 10.6 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. 10.6.2 80x1.20 mm M.S. laths with 1.20 mm thick top cover. 10.6.3 80x0.90 mm M.S. laths with 0.90 mm thick top cover. 428 10.7 Extra for providing suitable mechanical device chain and crank operation for operating rolling shutters. 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 10.7.2 Exceeding 16.80 sqm in area. 429 10.8 Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured). 430 10.9 Providing and fixing ball bearing for rolling shutters. 431 10.10 Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment). 10.10.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.10.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.10.3 Extra for providing and fixing steel beading of size 10x10x1.6mm (box type) approved shape and section with screws instead of glazing clips and metal sash putty in steel doors, windows, ventilators and composite units. 432 10.11 Providing and fixing L-iron or T-iron frames for doors, windows and ventilators of mild steel L-section or T-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.11.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 433 10.12 Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 434 10.13 Providing and fixing M.S. Tubular frames and shutters or frames only or shutters only for doors, windows, ventilators and cupboard with any sections, made of 1.60 mm or 1.25 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size as per drawing, including fixing of necessary butt hinges, stays and screws and applying a priming coat of approved steel primer excluding cost of all fittings such as handles, tower bolts, sliding door bolts, latches etc. and panels. 10.13.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). 10.13.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). 435 10.14 Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.14.1 Hot finished welded type tubes 10.14.2 Hot finished seamless type tubes 10.14.3 Electric resistance or induction butt welded tubes. 436 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats of Epoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. 437 10.16 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. 438 10.17 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. 439 10.18 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 440 10.19 Providing and fixing bolts including nuts and washers complete. 441 10.20 Providing and fixing M.S. rivets of sizes in position. 442 10.21 Welding by gas or electric plant including transportation of plant at site etc. complete. 443 10.22 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 444 10.23 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer. 10.23.1 M.S. tube. 10.23.2 E.R.W. tubes. 445 10.24 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge. 10.24.1 10x60 mm 10.24.2 10x80 mm 10.24.3 10x120 mm 10.24.4 10x140 mm 10.24.5 10x160mm 446 10.25 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 447 10.26 Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. 448 10.27 Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete. 10.27.1 With 4.0 mm thick glass panes 10.27.2 With 5.50 mm thick glass panes 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm box beading. 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. 449 10.28 Add extra for providing and fixing froasted glass instead of float glass. 10.28.1 With 4.0 mm thick glass panes. 10.28.2 With 5.5 mm thick glass panes. 450 10.29 Supplying at site: 10.29.1 R.C.C. Standards post/ struts/rails/ poles of mix 1:1.5:3 (1 cement : 1.5 sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in-charge including fixing (cost of earth works in excavation, concrete works in foundation to be paid separately). 10.29.2 Angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (cost of earth work in excavation and concrete work in foundation to be paid separately) 10.29.3 Supplying at site -Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming painting to be paid for separately). 451 10.30 Supplying and fixing turn buckles and straining bolts for barbed wire fencing. (Labour rate only). 452 10.31 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) with GI barbed wire. 453 10.32 Fencing with barbed G.I. wire angle iron post placed fitted to at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used. 454 10.33 Fixing Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, painting, earth work in excavation and cement concrete to be paid for separately). (Labour rate only). 455 10.34 Providing and fixing G.I. or PVC coated G.I.wire chain link fabric fencing of required width and mesh size including strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer- in-charge. (Cost of post, painting earthwork & c.c. to be paid separately) 10.34.1 Made of G.I. wire. 10.34.2 Made of G.I. wire, PVC coated to achieve outer dia. not less than 5mm in required colour and shade. 456 10.35 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and washers as required complete, with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer-in- Charge. (cost of post painting earth work & C.C. to be paid separately) 457 10.36 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). 458 10.37 Providing and fixing of ISI marked insulated fire rated GI Sheet doors conforming to FD 120-PI classification of IS 3614:2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The factory manufactured door frame and shutter assembly shall be made out of minimum 120 GSM coating as per IS: 277. Door and frame should be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The Door frame shall be single rebate grooved profile of size minimum 125 mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip. Frames to have inbuilt grooved to accommodate Intumescent fire seal strip of size 10x4mm. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonary wall opening. Note:- For grouting of Steel frames in masonary installations ;cement slurry of 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be recommended except head member(Payable in extra item). Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from minimum 1.2mm thick galvanised steel sheet. The infill material shall be mineral wool of minimum density 96 kg/cum. All doors shall befactory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 89x3 mm along with all suitable hardware (Payable in extra item).Vision lite size 185x285 (max area up to 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clip on arrangement. The glass will be provided with fire rated ceramic tape of min. 2 mm thickness with min. 15mm width al around on either face. Every Glass pane must carry a permanent marking of its glass manufacturer 459 10.38 Providing and fixing of factory make air tight casement windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 10.38.1 Openable window 10.38.2 Fixed windows 460 10.39 Providing and fixing of factory make single rebate openable/fixed windows made of roll formed galvanized pre- pained steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick) heavy duty pivot hinges per shutter and window fitted without glazing including 10mm square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. 10.39.1 Openable single rebate window 10.39.2 Fixed single rebate window 461 10.40 Providing and fixing of factory make double rebate windows made of roll formed galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self- expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete.. 10.40.1 Openable double rebate window 10.40.2 Fixed double rebate window 462 10.41 Providing and fixing of factory make fixed louvers fabricated from roll formed sections made of galvanized pre-painted steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, colour coated/powder coated Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in- charge complete. (glazing shall be paid separately as per SOR rate) 463 10.42 Providing and fixing of factory make pre painted steel sliding window 2 track-2 panel sliding window fabricated from roll formed sections made of galvanized steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 464 10.43 Providing and fixing pre painted steel sliding window 3 fabricated from Roll formed sections made of galvanized Steel with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns The above frames should be fixed to the concrete/masonry walls by means of self-expanding screws. Including filling the gap upto 5 mm depth and 5 mm width in between steel frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 465 11.1 40 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) 20mm nominal size stone aggregate in panels finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(Area of panel not to exceed 2.0 sqm) 466 11.2 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 467 11.3 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 468 11.4 Cement plaster skirting 18 mm thick (upto 30 cm height) with cement mortar 1:3 (1 cement: 3 sand) finished with a floating coat of neat cement. 469 11.5 Cement concrete pavement with Cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete. 470 11.6 Making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. 471 11.7 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1mm to 4mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.7.1 Dark shade pigment with ordinary cement. 11.7.2 Light shade pigment with white cement. 11.7.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.7.4 White cement without any pigment. 11.7.5 Light shade pigment with ordinary cement. 11.7.6 Ordinary cement without any pigment. 472 11.8 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 31mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 9mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 4mm to 7mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder : 7 marble chips) by volume including cement slurry etc. complete. (Area of panel not to exceed 2.0 sqm) 11.8.1 Dark shade pigment with Ordinary cement. 11.8.2 Light shade pigment with white cement. 11.8.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.8.4 White cement without any pigment. 11.8.5 Light shade pigment with ordinary cement. 11.8.6 Ordinary cement without any pigment. 473 11.9 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey yellow or green marble chips of sizes from 7mm to 10mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) by volume including cement slurry etc. complete : (Area of panel not to exceed 2.0 sqm) 11.9.1 Dark shade pigment with ordinary cement. 11.9.2 Light shade pigment with white cement. 11.9.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.9.4 White cement without any pigment. 11.9.5 Light shade pigment with ordinary cement. 11.9.6 Ordinary cement without any pigment. 474 11.10 Marble chips skirting (upto 30 cm height) 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 sand) : rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix :7 marble chips) by volume : 11.10.1 Dark shade pigment with ordinary cement. 11.10.2 Light shade pigment with white cement. 11.10.3 Medium shade pigment with 50% white cement and 50% ordinary cement. 11.10.4 White cement without any pigment. 11.10.5 Light shade pigment with ordinary cement. 11.10.6 Ordinary cement without any pigment. 475 11.11 Extra for laying terrazo flooring on staircase treads not exceeding 30 cm in width including cost of forming, nosing etc. 476 11.12 Providing and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors. 477 11.13 18 mm thick crazy marble stone white, black or as specified marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 12.5 mm nominal size), including rubbing, polishing and cement slurry etc.complete . 478 11.14 Precast terrazo tiles 22mm thick with graded marble chips of size upto12mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.14.1 Light shade using white cement. 11.14.2 Medium shade using 50%white cement and 50% ordinary cement. 11.14.3 Dark shade using ordinary cement. 11.14.4 Ordinary cement without any pigment. 479 11.15 Extra if terrazo tiles are laid in treads of steps not exceeding 30 cm in width. 480 11.16 Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1:3 (1 cement : 3 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : 11.16.1 Light shade pigment using white cement. 11.16.2 Medium shades pigment using 50% white cement and 50% ordinary cement. 11.16.3 Dark shade pigment using ordinary cement. 11.16.4 Ordinary cement without any pigment. 481 11.17 Chequeredterrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 sand) : 11.17.1 Light shade pigment using white cement. 11.17.2 Medium shade pigment using 50% white cement, 50% ordinary cement. 11.17.3 Dark shade pigment using ordinary cement. 11.17.4 Ordinary cement without any pigment. 482 11.18 Chequered precast cement concrete tiles any finish, any size 22 mm thick IS:13810-1993 ISI mark in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles, 15mm thick screed bad in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. 11.18.1 Light shade pigment using white cement. 11.18.2 Medium shade pigment using 50% white cement 50% Grey cement. 11.18.3 Dark shade pigment using ordinary cement. 11.18.4 Ordinary cement without any pigment. 483 11.19 Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sandand grey cement slurry, joints treated with white cement mixed with pigment to match colour of stone including rubbing and polishing complete with : (area of slabs over 0.5 sqm) 11.19.1 Makrana white second quality. 11.19.2 Raj Nagar plain. 11.19.3 Agaria White/Morgarh 11.19.4 Katni marble 11.19.5 Black Zebra. 11.19.6 Udaipur / Baroda green marble 11.19.7 Pink plain marble. 11.19.8 Jaisalmer Yellow 484 11.20 Marble stone 18 mm thick in riser of step, skirting, dado and pillar laid on 12 mm average thick cement mortar 1:3 (1 cement: 3 sand and laid with white cement slurry) joints treated with white cement mixed with pigment to match the shade of the slab i/c rubbing and polishing complete. (area of slab over0.50sqm.) 11.20.1 Makrana white second quality. 11.20.2 Raj Nagar plain. 11.20.3 Agaria White/Morgarh 11.20.4 Katni marble 11.20.5 Black Zebra. 11.20.6 Udaipur / Baroda green marble 11.20.7 Pink plain marble. 11.20.8 Jaisalmer Yellow 485 11.21 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (Area of slabs over 0.50 sqm.) 11.21.1 Makrana white second quality. 11.21.2 Raj Nagar plain. 11.21.3 Agaria White/Morgarh 11.21.4 Katni marble 11.21.5 Black Zebra. 11.21.6 Udaipur / Baroda green marble 11.21.7 Pink plain marble. 11.21.8 Jaisalmer Yellow 486 11.22 Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in- Charge. 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black 11.22.2.1 Granite fine grained dark crystal of other colours and various patterns 11.22.2.2 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns 11.22.2.3 Granite grey/pink/brown with various patterns 11.22.3 Cuddpah stone 487 11.23 Extra for prefinished nosing to treads of steps of marble stone. 488 11.24 Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre. 489 11.25 Extra for prefinished grooves to treads of steps of granite stone 490 11.26 Providing and laying machine cut, mirror polished, Italian Marble stone (18 mm thick Italian Marble stone slab, Perlato, Rosso erona, Fire Red or Dark Emperadore etc.)work in flooring laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry mixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 491 11.27 Providing and fixing machine cut, mirror / eggshell polished , Marble stone work 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. for wall lining (veneer work) including dado, skirting, risers of steps etc. thick cement mortar 1:3 (1 cement : 3 sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 492 11.28 Italian marble flooring in required design and patterns 11.28.1 Providing and laying machine cut, mirror polished Italian Marble stone 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadoreetc flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Note – This item shall be executed only after the prior approval of Chief Engineer. 493 11.29 Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). 111.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns 494 11.30 Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns 11.90.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns 492 11.31 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement: 4 sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. (area of slab more than 0.50 sqm) 11.31.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter 11.31.3 Gray/Pink/Brown or equivalent with various patterns 495 11.32 Deduct for not polishing granite flooring (item no 11.29 & 11.30) 496 11.33 Providing and laying Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing and as directed by the Engineer-in-Charge Granite stone slab Dark Black. Dark Red, White or equivalent, 11.33.1 Flamed Finish Polish 11.33.2 Leather Finish Polish 497 11.34 Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab. 498 11.35 Providing and fixing 10x10x7.50 cm Granite stone block hand cut andchisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 sand) with joints 10mm wide filled with same mortar mixed with matching pigment including ruled pointing etc. complete as per direction of engineer-in charge. 499 11.36 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm) 500 11.37 Deduction for using 20 mm thick slab instead of 25 mm thick slab of kota stone in item no 11.35 501 11.38 Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 502 11.38.1 10-12 mm thick 11.38.2 20 mm thick 503 11.39 Kota stone slab (area less than 0.5 sqm) rough chiseled dressed average 40 mm thick flooring for parking and open area of thickness over 20 mm (average) thick base laid over and jointed with grey cement slurry complete with base of cement mortar 1:4 (1 Cement : 4 Sand) 504 11.40 Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 11.40.1 Marble work 11.40.2 Granite work. 505 11.41 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 506 11.42 Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 507 11.43 Mirror polishing on marble work/Granite work/stone work wherever required to give high gloss finish complete. 508 11.44 Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1cement : 5 sand) with joints finished flush. 11.44.1 Red sand stone 11.44.2 White sand stone 11.44.3 Grey lime stone 11.44.4 Kota stone 509 11.45 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. 11.45.1 Red sand stone 11.45.2 White sand stone 510 11.46 40 mm thick machine rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 sand) mixed with pigment to match the shade of stone and pointing with same mortar 11.46.1 Red sand stone 11.46.2 White sand stone 511 11.47 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 512 11.48 Extra for Kota stone/ sand stone in treads of steps and risers using single length upto 1.05 metre. 513 11.49 Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 514 11.50 Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. 515 11.51 Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. 516 11.52 Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete. 517 11.53 Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete. 518 11.54 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. 519 11.55 Deduct for not using 20mm thick cement mortar 1:4 (1 cement: 4 sand) bedding in laying of floor tiles. 520 11.56 Fixing glazed/ Ceramic/Rectified/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. 521 11.57 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 522 11.58 Providing and fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 523 11.59 Providing and laying 500x500x40mm thick Turf paver on 150mm thick sub grade of compacted bed of 20mm nominal size stone aggregate and base course with 50mm thick sand and filling joints with sand including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer- in-charge. 524 11.60 Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and colour using acid and/ or alkali resisting mortar bedding and joints filled with acid and/ or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge. 525 11.60.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 sand)Acid and alkali resistant tile. 526 11.60.2 In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 sand).Acid and alkali resistant tile. 527 11.61 8 mm thick.stones Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. 11.61.1 Marble tiles (polished) Raj Nagar. 11.61.2 Granite tile of any colour /shade 528 11.62 Providing and fixing cramps of required size and shape in RCC/ CC /Stone/ Brick masonry backing with cement mortar 1:2 ( 1 cement :2 sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 11.62.1 Gunmetal cramps. 11.62.2 Stainless steel cramps. 529 11.63 Providing and fixing expansion hold fasteners of wedge expansion type on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 11.63.1 Fastener with threaded dia 6 mm. 11.63.2 Fastener with threaded dia 10 mm. 11.63.3 Fastener with threaded dia 12 mm. 530 11.64 Providing and fixing stone slab table rubbed on both faces edges rounded and polished of size as required and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. 11.64.1 White Agaria Marble Stone. 11.64.2 Granite Stone of approved shade. 531 11.65 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer- in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 11.65.1 300 mm Finished Floor Height (FFH) 11.65.2 450 mm Finished Floor Height (FFH). 532 11.66 Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. 533 11.67 Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period (This item is to be used only for operation theaters in hospitals) 11.67.1 1 mm thick 11.67.2 2 mm thick 11.67.3 3 mm thick 534 11.68 Providing and fixing acoustic PVC (Poly Vinyl Flooring) EN (European Standard) over fiberglass mat PVC foam backing (EN 14904), total thickness is 3.25mm (EN 428/EN 427), wear layer is 0.85 mm thick (EN 429), anti-bacterial and anti-fungus surface treatment , chemical resistance test qualified (EN-423)-high resistance, thermal and underfloor heating test qualified (EN12524) - all vinyl sheets must be linked crosswise with a continuous copper strip and finally connected to earth for grounding electrostatic electrical charges. Suitable and slip resistant. Recommended to use in area like Lecturer room, Conference room, Kids area, School, colleges, Residential and all commercial official scope etc. 535 11.69 Providing and fixing 2 mm thick heterogeneous PVC (poly vinyl flooring) EN (European Standard) with wear layer is 0.55mm thick of PVC, total weight is 2300 g/m2 approx. PUR (polyurethane reinforced), residual indentation approx.0.05 mm, castor wheel test qualified, dimensional stability ≤0.10%, static electrical charge .The floor finish should termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto100mm. Recommended to use in area like Patient rooms , Doctor room Lecturer room, Kids area, School, Colleges, Residential and all commercial official scope etc. 536 11.70 Providing and fixing 8mm and above thick laminated (wooden flooring) of AC4 and above grade product of approved made out of core high density fibre board (HDF), surface layer shall be high preasure laminated treated for abrasion, scratch, moisture protection, flame protection U.V resistant, layer of acrylic resin, aluminium oxide or similer layer having above properties, backing under layer on min 2 mm thickness shall provide as sound absorbent and moisture protection layer, The seamless impregenated decorative layer of specified size, design, colour and pettern, all bonded together under high temperature and pressure with eco-friendly. The material shall be applicable warranty formaldehyde free, eco- friendly and fully recyclable (eco-freindly) and matching shed and excluding quantity of skirting and profile. 537 11.71 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, 1:6 (1 cement : 6 sand) including filling the joints with same mortar, with common burntclay non modular bricks 11.71.1 100 mm thick 11.71.2 200mm thick 538 11.72 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colour and pattern over 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade 11.72.2 60 mm thick C.C. paver block of M-35 grade 11.72.3 60 mm thick C.C. paver block of M-30 grade 539 11.73 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in- Charge). 540 11.74 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side(top & bottom), including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-Charge. 541 11.75 Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite of approved shade, colour and texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand) Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. 11.75.2 Granite Door frame for 200mm thick wall Thickness. 542 11.76 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11.76.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 543 11.77 Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 77.1 Plain ivory light shade : Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) : Size 600X600mm thickness 9-10mm 544 11.78 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 78.1 In light shade glossy/ rustic /stain finished 11. 78.1.1 Size 600X600 mm thickness 9-10 mm 11. 78.1.2 Size 800X800mm thickness 11-12mm 11. 78.1.3 Size 800X1200 mm thickness 11-12mm 11. 78.2 In dark shade glossy/ rustic /stain finished 11. 78.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 78.2.2 (b) Size 800X800mm thickness 11-12mm 11. 78.2.3 (c) Size 800X1200 mm thickness 11-12mm 545 11.79 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 79.1 In light shade glossy/ rustic /stain finished 11. 79.1.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.1.2 (b) Size 800X800mm thickness 11-12mm 11. 79.1.3 (c) Size 800X1200 mm thickness 11-12mm 11. 79.2 In dark shade glossy/rustic/stain finished 11. 79.2.1 (a) Size 600X600 mm thickness 9-10 mm 11. 79.2.2 (b) Size 800X800mm thickness 11-12mm 11. 79.2.3 (c) Size 800X1200 mm thickness 11-12mm 546 11.80 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 80.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 80.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.1.2 (b) Size 600X600mm thickness 9-10mm 11. 80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 11. 80.2 In dark colour and shade etc. 11. 80.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 80.2.2 (b) Size 600X600mm thickness 9-10mm 11. 80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) 547 11.81 Providing and laying vitrified floor-tiles Full Body Design Homogenous Body matt/rustic finish in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting, riser laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm 548 11.82 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality including grouting the joints with white cement and matching pigments etc. complete 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm 11. 82.1.2 Size 800X800mm thickness 11-12mm 11.82.1.3 Size 800X1600 mm thickness 11-12mm 11.82.1.4 Size 1000X1000 mm thickness 11-12mm 11. 82.1.5 Size 600X1200 mm thickness 11-12mm 11. 82.1.6 Size 800X1200 mm thickness 11-12mm 11. 82.1.7 Size 1200X1200 mm thickness 11-12mm 11.82.1.8 Size 1200X1800 mm thickness 11-12mm 11.82.1.9 Size 1200X2400 mm thickness 11-12mm 11. 82.2 For wall stain / rustic finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e.within 6 hours, Size 300X600 mm thickness 9-10 mm 11. 82.3 For wall polished / Glossy finished laid on 12mm thick cement mortar 1:3 (1 cement:3sand) prepared same day when mortar is still green i.e. within 6 hours, Size 300X600 mm thickness 9-10 mm 549 11.83 Providing and laying digital print random design(PGVT)/(GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete 11. 83.1 For skirting, risers etc. glossy/ rustic /stain/matt finished in all colours and shades 11. 83.1.1 Size 600X600 mm thickness 9-10 mm 11. 83.1.2 Size 800X800mm thickness 11-12mm 11. 83.1.3 Size 600X1200 mm thickness 11-12mm 11. 83.1.4 Size 800X1200 mm thickness 11-12mm 550 11.84 Granite work gang saw cut (polished machine cut) of thickness 12 mm for wall lining, skirting, risers of steps and dado (veneer work), back filling with a grout of average 12 mm thick in cement mortar 1:3 (1 Cement: 3 sand) including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the beaching by means of cramps, which shall be paid for separately). 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 84.1.3 Gray/Pink/Brown with various patterns 551 11.85 Providing and laying gang saw cut 12mm thick, mirror polished pre moulded (wherever required) and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in flooring laid over 20mm thick base of cemnt mortar 1:4(1cement:4sand) including grouting the joints with white cement mixed with matching pigments, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns 11. 85.1.3 Gray/Pink/Brown with various patterns 552 11. 86 Providing and fixing artificial synthetic green long and fine yarns grass, UV/water resistant with SBR latex backing eco-friendly durable high density 100 % PP ( Poly Poplin ) anti UV fiber.denier 12000 dtex, stich rate 18 stiches per 10cm, stich density 16800 stiches/m2, tufted weight 1830g/sqm approx. 11. 86.1 Roll size will be 25.00m X 2.00m (25mm thick)- weight 150kg- per roll. 11. 86.2 Roll size will be 25.00m X 2.00m (40mm thick)- weight 180kg- per roll. 553 11.87 Providing and fixing laminated (engineered wooden flooring) of suitable thickness 10-14 mm of suitable grade category product of approved made out of core high density fibre board (HDF) &other component it treated for abrasion ,scratch ,moisture protection, flame protection,U.V resistant. backing with eco- friendly resins specified by the manufacturer .The material shall be applicable warranty formaldehyde free, eco friendly, highly recommended for high traffic area and fully recyclable and matching shed and excluding quantity of skirting and profile. 554 11.88 Providing and fixing single layer homogeneous (solid wooden flooring) of suitable thickness 14 - 18 mm of suitable grade category product of scratch protection, moisture protection, flame protection U.V. resistant, backing under layer on min 2 mm thickness The material shall be applicable warranty formaldehyde free, eco friendly ,highly recommended for high traffic area and fully recyclable and matching shade and excluding quantity of skirting and profile. 555 11.89 Providing and fixing tuffed 1/10” loop pile (carpet tile / Carpet). EN (Euorpean Standard) size 50cm x 50cm /roll Size of total thickness 5.5 mm and above with total mass of 4100g/m2approx and with polyester fleece primary backing with standard dimensional stability with impact sound / noise reduction and recommended for high traffic acoustical area. 556 11.90 Providing and fixing spc (stone plastic composite) virgin pvc water resistant proof vinyl flooring with a thickness between 4 to 8mmuv coated layer with a wear layer of 0.3 to 0.80mm with a SPC core layer of 2.00 to 5.00 mm with a SOP of heat resistant, voc free, easy to cut, anti microbial protection in the form of tiles, planks helpful in environmental of profection health. 557 11.91 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone tile flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with white cement mix with matching pigment etc. complete as per direction of Engineer-in-Charge. 11. 91.1 300x300mm 11. 91.2 400x400mm 11. 91.3 600x600mm 558 11.92 Providing and laying pre mirror polished/ pre polished fine grain machine cut sand stone slab flooring 20mm thick (hardness should not be less than 7 and water absorption should not be more than 0.3%) of required size of area more then .50 sqm and shape of approved shade, flooring in plazas open staircase and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joint with cement mix matching pigment etc. complete as per direction of Engineer -in-Charge. 559 12.1 Providing corrugated G.S. Sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00mm thick with zinc coating not less than 275gm/m² 12.1.2 0.80mm thick with zinc coating not less than 275gm/m² 12.1.3 0.63 mm thick with zinc coating not less than 275gm/m² 560 12.2 Straight cutting in G.S. sheet of any thickness roofing for making opening of area exceeding 40 sq. decimetre for chimney stacks, sky light etc. 561 12.3 Extra for circular cutting in C.G.S. sheet of any thickness roofing for making opening of area exceeding 40 square decimetre : 562 12.4 Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² 563 12.5 Providing valleys of 90cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. G.I. limpet and bitumen washers complete. 1.60 mm thick with zinc coating not less than 350gm/m² 564 12.6 Providing and Fixing of 40 cm over all width plain, G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1cement : 3 sand). 1.00mm thick with zinc coating not less than 275gm/m² 565 12.7 Providing and fixing 15 cm wide 45 cm over all semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² 566 12.8 Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia.G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. 567 12.9 Extra for straight cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc.. 568 12.10 Extra for circular cutting in reinforced by organic fibres and/or inorganic synthetic fibres cement corrugated/ semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter. 569 12.11 Extra for providing and fixing wind ties of 40x 6 mm flat iron section. 570 12.12 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. 12.12.1 Corrugated serrated adjustable ridges 12.12.2 Plain wing adjustable ridges 12.12.3 Close fitting adjustable ridges 12.12.4 Unserrated adjustable hips 571 12.13 Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: 12.13.1 Corrugated apron pieces 12.13.2 Eaves filler pieces 12.13.3 North light curves 12.13.4 ventilator curves 12.13.5 Barge boards 12.13.6 Ridge finials 12.13.7 Special north light curves 12.13.8 S type louvers 572 12.14 Providing flat iron brackets 50x3mm size with necessary bolts, nuts washers etc. for fixing G.S. sheets gutters with purlins. 573 12.15 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS:277 in 240 mpa steel grade, 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 574 12.16 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self- tapping screws complete : 12.16.1 Ridges plain (500 - 600mm). 12.16.2 Flashings/ Aprons.( Upto 600 mm) 12.16.3 North light curves. 12.16.4 Barge board (Upto 300 mm) 12.16.5 Crimp curve 12.16.6 Gutter. (600 mm over all girth) 575 12.17 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. 12.17.2 2mm thick flat. 576 12.18 Providing and Fixing of sky lights consisting of Multi cell/tight cell Polycarbonate Panel System of approved colour, 16 mm thick (minimum) having uniform in color with an integral Tight-Cell core constructed not to exceed 4mmx4mm in a cross section, involved such as bolts nuts and screws etc. and labour for cutting bending to required profile, necessary scaffolding, hoisting in position etc. for proper completion of the work etc. complete as per specification drawings and direction of Engineer in charge. Finished surface area of roofing fixed over steel tubular structure shall be measured for payment. MS tabular frame work shall be measured separately for payment. 12.18.1 10mm thick 12.18.2 16mm thick 577 12.19 Providing sand stone slab 40 to 50 mm thick for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately) including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 sand ) complete : 12.19.1 Red sand stone slab 12.19.2 White sand stone slab : 578 12.20 Painting top of roofs with residual type petroleum bitumen of grade VG 10 of approved quality @ 17kg per 10 sqm impregnated with a coat of sand at 60 cum per 10sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 579 12.21 Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance and thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall be strictly as per manufacturers specifications and as approved by engineer In charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., and washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer-in-charge. 580 12.22 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection >0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 581 12.23 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 sand) and finished neat complete. 582 12.24 Providing and fixing on roof pressed clay tile (Mangalore tile) 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) 583 12.25 Providing and laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness of approved pattern on steel frame work complete (steel frame work to be paid separately) 584 12.26 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase 585 12.27 Making khurras 45x45 cm (sunk area) with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete so as to receive rain water/ spillage water on roof in a sunk area and completely rain out in a near perfect strain meter motion into rain water pipe. 586 12.28 Providing and fixing M.S. holder bat clamps of approved design to C.I. Or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. 12.28.1 100 mm diameter 12.28.2 150 mm diameter 587 12.29 Providing and fixing ISI marked sand cast iron rain water pipes. 12.29.1 100 mm dia minimum wall thickness 5mm 12.29.2 150 mm dia minimum wall thickness 5mm 588 12.30 Providing lead caulked joints to sand cast iron rain water pipes and fittings : 12.30.1 100 mm dia. Pipe 12.30.2 150 mm dia. Pipe 589 12.31 Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) : 12.31.1 Sand cast iron bend : 12.31.1.1 100 mm diameter 12.31.1.2 150 mm diameter 12.31.2 Sand cast iron plain shoes : 12.31.2.1 100 mm diameter 12.31.2.2 150 mm diameter 590 12.32 Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) 591 12.33 Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) 12.33.1.2 110 mm (minimum wall thickness 2.2mm) 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) 12.33.2.2 110 mm (minimum wall thickness 2.2mm) 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) 592 12.34 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.34.1 75 mm (minimum wall thickness 1.8mm) 12.34.2 110 mm (minimum wall thickness 2.2mm) 593 12.35 Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. 594 12.36 Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. 595 12.37 Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand) 12.37.1 Stone ware spout 12.37.2 Upvc spout (Pipe dia.110 mm) 596 12.38 Providing and fixing of self-supported mechanically seamed roofing system, made of high quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A 792 M of base metal thickness from 0.8 mm to 1.6mm (tolerance ± 0.02mm). High grade steel sheet should have 55% aluminum and 45% zinc coating by hot-dip process of minimum 25 micron The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolts, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers/clamps for installation of lighting /fixtures /utility/ duct as per requirement and ventilators, skylight can also be provided at crown/ridge by making cuts into the panels which is to be paid separately. This item shall be executed only by the agency which has all required manufacturing machineries and necessary expertise. 12.38.1 Base metal thickness 0.8mm up to span 15 meter 12.38.2 Base metal thickness 0.9mm , up to span 18 meter 12.38.3 Base metal thickness 1.0 mm, up to span 21 meter 12.38.4 Base metal thickness 1.1 mm, up to span 23 meter 12.38.5 Base metal thickness 1.2mm, up to span 25meter 12.38.6 Base metal thickness 1.3 mm, up to span 27 meter 12.38.7 Base metal thickness 1.4mm, up to span 29meter 12.38.8 Base metal thickness 1.5 mm, up to span 31 meter 12.38.9 Base metal thickness 1.6 mm, up to span 33 meter 12.38.10 Providing and fixing galvalume 1.0 mm thick clamps/hangers of size 75X140mm with saddle of 50mm dia, riveted at one side and nut and bolt at other side, to self-supported roofing system by mechanical seaming to suspend light fixture/cable stay/false ceiling/duct etc., at their location which should be planned earlier by engineer-in-charge. Clamps shall be fixed during seaming of panels. 12.38.11 Providing and fixing advanced type hurricane turbo ventilator to self- supporting roof having neck dia 600mm made of aluminum having 24 nos vertical vanes made of aluminum sheet. Ventilator should be fixed on 1 to 2mm thick G.I. ring which shall be fixed on 2mm thick polycarbonate sheet. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates i/c of all material, labour fittings screw, rings, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 12.38.12 Providing and fixing of 2mm thick polycarbonate sheet to self-supported roofing system. The sheet shall have tensile strength and elongation as per ASTM D 638, refractive index as per ASTM D 592, light transmission as per ASTM D 1003 and specific gravity as per STM D 792. Polycarbonate sheet shall have foam tap or rubber gasket under and over it and fixed by 1 to 2 mm thick aluminum angle 25X25mm with self- tapping screw to panels. All joints shall be sealed by silicon. Rates include of all material, labour, fittings, screw, foam tap, aluminum angles etc. complete. Deduction shall not be made for cutting area of self-supported roof. 597 12.39 Supply, fabrication and erection of three-dimensional space frame steel structure consisting of support node, primary space frame members, space notes nodes, bolts, sleeves (nut), purlin stool, purlin etc. to support roof sheet in plain or curved shape. (Approximate zinc coating thickness 77 Microns) and shall not be less than 400 g/sqm (Approximate zinc coating thickness 56 microns). Bolts, sleeves and cones shall be electro-galvanized to ASTM B 633 Type 2, SC3. Shop drawings along with structural design analysis shall be provided by the manufacturer for approval of the engineer in charge. Rate shall include cost of design, all material, all lifts, labour, transport, storage, machines, tools and plants, wastages, erection and installation at site all necessary scaffolding etc. necessary to provide finished product but excluding cost of erection/construction of support shaft and roof sheet. 598 12.40 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). 599 12.41 Providing and fixing in position roof tile under lay using 12mm thick(minimum) Moisture/fire Resistance heavy duty fibre cement board(High Pressure Steam Cured) Type A,Category 4 conforming to IS 14862:2000, fixed on Steel frame work of 610mmx610mm or 610mmx1220mm grid by counter sunk stainless screw @ 300mm C/C all complete as per the drawings. Tiles etc may be laid on the board substrate by sealing the joints properly with filler material or sealant to ensure no leakage through joints. All complete as per drawings, specification and as per direction of Engineer-in-Charge.Note - MS Section structure and roof tile like Shingles/Mangalorian Tiles etc cost will be paid seprately. 600 12.42 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183 density 24kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 601 12.43 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183, density 16kg/m3, 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 602 12.44 Thermal Insulation of roofing with Expanded polystyrene fixed with suitable adhesive to the false ceiling as per the directions of the Engineer-in-charge : 603 12.44.1 With Type N - Normal 50 mm thick 604 12.44.2 With Type SE - Self Extinguishing type 50 mm thick. 605 12.45 Providing and laying thermal insulation of roofing with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 mx2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. 606 12.46 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in- Charge. 607 12.47 Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183, density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. 608 12.48 Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing GI wire. 609 12.49 Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge. 610 12.50 Supply and application of 48kg/m3 density & 50 mm thick with a tolerance of -2 + 6mm of Rockwool RB slabs unfaced (Binder<3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non- combustible when tested as per BS 476 Part 4 or A1 when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 611 12.51 Supply & Application of Rockwool RB slab 48kg density, 50mm thick wrapped in 200G vergine polythene bags for partition, ceiling (Under Deck insulation) conforming to IS: 8183 with tolerance of -2 +6mm of rock wool RB slabs unfaced (Binder <3.5%) conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested per EN 13501. . Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 612 12.52 Supply & Application of Rockwool RB 2 slab 64kg /m3, 50mm thick, with GI wire netting 24 SWG; fixing for NRC Value 1.00 for Acoustics, thermal & fire purpose conforming to and IS: 8133, IS: 8183 with tolerance of -2 + 6mm of RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Two random samples from each supplied batch will be tested for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 613 12.53 Supply & Application of Rockwool building roll (1.1mx10m) 48kg density, 50mm thick with FSK (foil scrim Kraft) aluminium foil facing for HVAC duct & building underdeck purpose conforming to IS: 8183, IS: 8183 and IS:8183 a tolerance of -2 +6 mm of Rockwool RB slabs unfaced (Binder < 3.5%) ; conforming to IS: 8183; /ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS: 476 Part 4 or Al when tested as per EN: 13501. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and it shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 614 12.54 Supply & Application of Rockwool Building Roll (1.1mX10m) 48kg density, 50mm thick with ALG (Alu & glass) mixture of Aluminium & glass facing for building underdeck application below metal sheet also conforming IS: 8183, IS: 8183 and IS: 8183 a tolerance of -2+6mm of rockwool RB slabs unfaced (Binder < 3.5%); conforming to IS: 8183/ASTM C 612 latest edition with amendments. Non-combustible when tested as per BS 476 Part 4 or Al when tested as per EN 13501. The maximum service temperature shall be 700°C. Shot content should be less than 2% for 500 microns & less than 10% for 250 microns when tested as per standard IS: 3144. Two random samples from each supplied batch will be test for shot content at the site. The melting point of the wool shall be more than 1000°C and wool shall be bio-soluble in accordance with EU directive 127/2008 or similar. All Above mentioned standard are as per latest edition with amendments. 615 12.55 Providing and fixing of minimum 12mm thick, 5 layered bubble Reflective thermal insulation made of 12 microns aluminum foil with minimum 97% Reflectivity on both outer sides, under both aluminum foil 4mm thick FR bubble insulation with Low Emissivity - 0.032 (ASTM1371), Fire Class A (ASTM E84) All five layers of insulation shall be stick with each other by registered manufacturer using hot process without using any kind of adhesive. Insulation shall be supplied in 1.10m wide roll width with 50mm wide factory-made cuts at both sides to joint another roll by using general stapler in case of new shed and adhesive in case of existing or self-supported roof. 12.55.1 Fixing of insulation on new work by laying horizontally on the purlins and perpendicular to the direction of purlins and fixing by using self- tapping screws at equal distance. Place and align the second roll of insulation parallel to the first roll and overlaps the adjacent rolls. After Insulation is fixed over the purlins the metal sheet is placed over insulation and drilled with self-tapping screws with purlins etc. complete, including all material and scaffolding. 12.55.2 Installation of insulation in Old Sheds where the sheets have been already fixed over the purlins so insulation shall be fixed under the purlins covering the roof bottom. Insulation roll to be unfolded at the bottom of the purlin horizontally and parallel to the roof and fixed by using the self- tapping screw with a washer at equal distance etc. Complete, including all material and scaffolding. 12.55.3 Insulation of Self-Supported Roof shall be applied under the roofing by using stud welding to the self- supported roof at a distance not be more than 300 mm in both directions. At each stud insulation roll shall be pushed against the studs so that it gets punctured and then non-returning washer has to be applied at the stud etc. complete, including all material and scaffolding. 616 12.56 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over- deck on ceiling surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM C 518, compressive strength of > 350 kPa listed as per ASTM C 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorption < 1% by volume as per ASTM C 272, oxygen index of minimum 24 as per ASTM D 2863 and Fire retardant property as per DIN 4102, with preferred stone or pre-cast tiles shall be laid over the XPS board with suitable grouting including providing pre-fabricated EPDM drain outlets (Cement Screed casting shall be done at the junction of roof and parapet walls), all as per the directions of Engineer-in-charge. 617 12.57 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 618 12.58 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board 12.58.1.1 Flat surfaces 12.58.1.2 Curved surfaces 12.58.1.3 Sunk or raised mouldings 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I : 2011 (Board with BIS certification marks). 12.58.2.2 Fire resistant Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) 12.58.2.3 Gypsum moisture resistant board. 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturers specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. 619 12.59 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of mainT runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.59.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.59.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 12.59.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a ompletely sealed unit. 12.59.4 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 12.59.5 Glass fiber Acoustical Suspended Ceiling System with 16 mm thick tegular edge or micro look edge tiles of size 595x595mm.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥83%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and7) in module size of 600 x 600 x 16mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38 - 41%. The Tile and Grid system used together should carry a 15 year warranty. 12.59.6 8mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primedcolour tiles of size 595X595 mm. 12.59.7 6mm thick non-asbestos multipurpose termite, fire & moisture resistance cement bonded particle board as per IS: 14276, white primed colour tiles of size 595X595 mm. 620 12.60 Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300mm center to centre, suspending the main C carrier and in direction perpendicular to it at 600mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive) Fixing with clip in/swing down tiles into spring T with 12.60.1 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 12.60.2 GI Metal Ceiling Clip in /swing down plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 621 12.61 Providing & Fixing of Unperforated Antibacterial Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.7mm thick aluminium alloy 3105 with beveled edge of 4.15mm width and height of 32mm. The Tile will be manufactured on advanced equipment that includes several levelling stages in the manufacturing process by approved certified manufacturers. The Tile shall be clipped into clip in rail of 0.5mm thick G.I. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G.I.Road, Hold on Clamp with Clip. (Rate include all materials and labour). 622 12.62 Providing and fixing board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately): 12.62.1 12mm thick insulating board 12.62.1.1 Natural colour insulating board 12.62.1.2 White face insulating board 12.62.1.3 Flame retardant face insulating board 12.62.2 Flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 12 mm thick marked in ceiling with necessary nails etc. complete 12.62.3 6 mm thick plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete 12.62.4 6mm thick High Pressure Steam Cured non asbestos, reinforced with cellulose fibres,Moistur& fire Resistance heavy duty fibre cement board, Type A,Category 4 conforming to IS 14862:2000.(for wet areas) 12.62.5 4 mm thick High Pressure Steam Cured non asbestos, pre-painted, self- embossed, designer cement boardType B, Category 3 conforming to IS 14862:2000 . of approved texture,design patterns 623 12.63 Extra for Circular cutting and wastages in ceiling with: board only (frame work) Natural colour insulating 12 mm thick board paid separately. 624 12.64 Extra for providing and fixing ceiling to curved surfaces in narrow widths 625 12.65 Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminium primer on both sides and edges including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately). 626 12.66 Providing and Fixing colour coated profile sheet of minimum 1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. The sheet shall be fixed using self- drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape 627 12.67 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain or design particle board ceiling tiles. 628 12.68 Providing and fixing expanded polystyrene (thermacol) false ceiling (frame work to be paid separately) : 12.68.1 With Type N - Normal 50 mm thick 12.68.2 With Type SE - Self Extinguishing type 50 mm thick 629 12.69 Providing and fixing false ceiling with fabric fixing with nail etc. (frame work and beading to be paid separately). 12.69.1 costing upto 70/- per metre, 12.69.2 Rs 70- 150 per meter 12.69.3 Upto 200 per meter 630 12.70 Providing and fixing perforated Aluminium panel ceiling of white/ natural satin colour supplied by approved manufacturers consisting of panel of standard size with bevel edge, panel length up to 6 m, coil Coated on a Continuous Paint Line suitable for Interior application, double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 5050 (Al. Mg) for higher strength and good roll forming characteristics. Panel carrier shall be suspended by means of G.I. threaded rod having 6 mm diameter at a distance of 1.5 mtr. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.70.1 With panels of size 300mm wide X30mm deep X 0.7mm thick and panel carrier of size 40.5mm wide X 62mm deep X 0.9mm thick 12.70.2 With panels of size 150mm wide X 15.5 mm deep X 0.5mm thick and panel carrier of size 32mm wide X 39mm deep X 0.95mm thick 12.70.3 With panels of size 84mm wideX16mm deep X 0.5mm thick and panel carrier of size 62mm wide X 29mm deep X 0.95mm thick 631 12.71 Providing and fixing un-perforated Aluminium Panel ceiling Supplied by approved manufacturers of standard white/ natural satin shade consisting of panel 30 mm/80mm/130mm/180mm wide X 15 mm deep X 0.5mm /0.6mm thick respectively, with square edges having panel length up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 5050 (Al.Mg) for higher strength and good roll forming characteristics. The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter, and a Galvanised suspension spring clip at a distance of 1.7mtrs centre to centre. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 632 12.72 Providing and fixing U Baffle Aluminium panel ceiling of different colors and finish supplied by approved manufacturers, consisting of panel size 50 mm width X 100 mm deep using 0.6 mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Actual distance of threaded rod/carrier might vary and to be calculated based on the actual drawing and site condition. The measurements shall be wall to wall without any deductions for lights, diffuses, columns etc. As an option, ceiling area above U Baffle can be painted by the contractor in black colour or any other colour as per the architect for better aesthetics before fixing this system. 12.72.1 Standard White / Natural Satin Shade 12.72.2 Wooden Finish 633 12.73 Supply & Fixing of perforated G.I false ceiling tile or plank using torsion spring fixing system supplied by approved manufacturer comprising of tile of 600 mm wide and 600 mm long manufactured out of 0.5 mm thick or plank of 600mm wide and 1200 mm long manufactured out of 0.6mm thick galvanised steel perforated with 2 mm dia. at a distance of 5mm centre to centre. Non-woven felt made of glass- reinforced fibre glued over the perforation at the back side of panels to provide noise reduction co efficient up to 0.7 NRc. “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross runners 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced at a spacing of 600 mm on centre maximum. The measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. 12.73.1 Tile of 600 mm wide ,600 mm long and 0.5 mm thick 12.73.2 Plank of 600mm wide ,1200 mm long and 0.6mm thick 634 12.74 Providing and fixing of composite perforated Gypsum board with Glass wool Fiber panel of Size 595x595x25 mm with 10mm square Perforation tiles false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “ “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 635 12.75 Providing and fixing of Composite perforated MDF board with Glass wool Fiber panel of Size 595x595x18 mm 10mm Square Perforation tiles (Square /Tegular Edge) false ceiling in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 636 12.76 Providing and fixing of Perforated Gypsum board with Acoustical Glass Fiber Tissue faced panel of Size 595x595x12.5mm, Square 10mm Perforation tiles (Square Edge) false ceiling panels in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (Galvanized @ 120 gms/sqm both sides inclusive) consisting of main “T” runners to be suspended from ceiling using GI slotted plates of size 27x37x25x1.6 mm fixed to ceiling with 12.50 mm dia and 40 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.80 mm spaced @ 1200mm centre to centre along with main T, bottom exposed width of 24mm of all T-sections shall be pre- painted with polyester paint all complete at all heights as per specifications and drawings and as directed by Engineer-in-Charge. 637 12.77 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance≥ 85%, Thermal Conductivity k = 0.052 -0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling usinggalvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) 638 12.78 Providing and fixing false ceiling at all heights with 15 mm thick integral densified micro look edged non- cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.80 grams per sqm) i.e. 50 mm long, 12 mm outer diameter M-6 dash fasteners with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 639 12.79 Providing and fixing false ceiling at all heights with 15 mm thick integral densified mirolook edge with BIO SAFE coating as per ISO 7251:2005, ISO 20743:2007 and ISO 21527-1:2008, making the tiles resistant to bacterial growth in case of any external bacterial contact made onto the surface of tiles, non-cementitious light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm with the help of Z cleat of 27x37x27x2 mm, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 640 12.80 Providing and fixing in position wall panelling at all heights with 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles., non-cementitious, reinforced with fibre and natural filler, having NRC (Noise Reduction Coefficient) of 0.10-0.20 for plain and designer 0.15-0.40 for pinhole texture and NRC 0.45-0.65 for fully perforated tiles as per IS 8225:1987, sound attenuation STA-32db. of 0.75 (minimum) as per IS 8225:1987, Light Reflectance of 85% (minimum), non-combustible as per BS:476 (part-4), 50-52% recycled content including fly ash, The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fibre joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturers specification as per direction of engineer-in-charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles. 641 12.81 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. 12.81.1 With semi perforated 12mm thick micro tegular edged GRG false ceiling tiles. 12.81.2 With fully perforated 10mm thick square edged GRG false ceiling tiles for sound proof and acoustic. 642 12.82 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped 387alvanized steel sections (387alvanized387 @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cros‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer- in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 643 12.83 Providing and fixing upvc plank, Plank size (340 X 2700 ) mm as per approved shade, the panel shall be laser catted end of plank fixing j-trim fixed and corner edge of ceiling fixed u pvc clip same colour and providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 125 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular,j trim end clip includes in this item any other item not be paid sepratly complete in all respect as per the directions of Engineer-in-Charge. . 644 12.84 Providing & Fixing PVC ceiling system profile panel with click system interlock panel size 4000mmx340mmx1mm resistance to weather perfect finish in wood grain & solid colour maintenance free Resistance to weather truly anti bacterial. with edge profile J-trim on periphery & center profile T-trim in panel joint Complete System to be fixed on G.I. framework of ceiling section at 450 mm distance with enter section suspended by roof by G.I. angle hanger in proper line & level etc complete . PRODUCT SPECIFICATIONS: Meets or exceeds the standard specification of (ASTM D-4477) and its referenced documents. observed. (Tested at 50 LBS) Tensile strength, MPa: >37.0 Tensile modulus, MPa: >2000 Surface distortion: None at 120F Squareness: <1/8” of square Length: Within ¼” of specification Lock control: Complies Color Change: <2 grayscales (16 hrs under 1200W/m2 UV radiation at 50 degrees) 645 12.85 Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener, clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding in proper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PUpaint of approved colour in desired shape. With 1050 GSM tensile fabric 12.85.1 With precontraint tensile membrane 1050 GSM (20 years Warranty) 12.85.2 With precontraint tensile membrane 1050 GSM (15 Years warranty) 646 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement : 4 sand) 13.1.2 1:6 (1 cement : 6 sand) 647 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix 13.2.1 1:4 (1 cement : 4 sand) 13.2.2 1:6 (1 cement : 6 sand) 648 13.3 20 mm cement plaster of mix : 13.3.1 1:4 (1 cement : 4 sand) 13.3.2 1:6 (1 cement : 6 sand) 649 13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 13.4.1 1:3 (1 cement : 3 sand) 13.4.2 1:4 (1 cement : 4 sand) 650 13.5 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 13.5.1 1:3 (1 cement : 3 sand) 13.5.2 1:4 (1 cement : 4 sand) 651 13.6 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement : 4 sand). 652 13.7 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 sand) finished rough with sponge. 653 13.8 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) 654 13.9 6 mm cement plaster 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 655 13.10 Neat cement punning 656 13.11 Rough cast plaster upto 10m height above ground level with a mixture of sand and gravel or crushed stone from 6mm to 10mm nominal size dashed over and including the fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. Finished with ordinary cement. 657 13.12 Pebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement: 4 sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement: 3 sand) mixed with 10% finely grounded hydrated lime by volume of cement. 658 13.13 Providing sand faced plaster upto 10meter hight above ground level concrete or brick masonry surfaces in two coats, base coat of 13 mm thick in cement mortar 1:4 (1 cement: 4 sand), clearing the surface by combing it and finishing coat of 8 mm. thick in cement mortar 1:3 (1 cement: 3 sand) and taking out surface grains by mechanical arrangement or applying second coat by mechanical means including cost of all material, labour, and T and P including all lead, lift and scaffolding etc. complete. 659 13.14 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 660 13.15 Extra for plastering 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof 661 13.16 Extra for plastering on circular work not exceeding 6 m in radius: 13.16.1 In one coat 13.16.2 In two coats 662 13.17 Extra for plastering done on moulding cornices or architraves including neat finish to line and level: 13.17.1 In one coat 13.17.2 In two coats 663 13.18 Extra for plastering Spherical, Groined ceiling, Flewing soffits. 13.18.1 Spherical ceiling 13.18.2 Groined ceiling 13.18.3 Flewing soffits 664 13.19 Washed stone grit plaster on exterior walls of height upto 10 M. above ground level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings,complete as per specification and direction of Engineer- in- charge (Payment for providing grooves shall be made separately). 665 13.20 Forming groove of uniform size 20 or 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 666 13.21 Extra for washed grit plaster on exterior/interior walls of height more than 10m from ground/floor level for every additional height of 3 m or part thereof. 667 13.22 Extra for washed stone grit plaster on circular work not exceeding 6m in radius (in two coats). 668 13.23 Forming groove of uniform size from 12x12mm and upto 25x15mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. 669 13.24 Extra for using white cement in place of ordinary cement in the top layer of the item of washed stone grit plaster. 670 13.25 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part -1 and II) 1976, applied on hacked/ uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations,excluding in wall which may come in contact with dampness finished in smooth line and level etc. complete. 671 13.26 Extra for addition of synthetic Polyester triangular fibre of length 6mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125gms. Of synthetic Polyester triangular fibre for 50 Kgs. cement used in cement mortar as per directions of Engineer-in-Charge. 672 13.27 Providing and fixing mesh in vertical and horizontal junction of RCC and brick/AAC work including scaffolding and all lead and lift etc. complete 673 13.27.1 G.I. chicken mesh as per ISI specification and in the required width with 50mm long Bombay nails before plastering upt 10 meter height. 13.27.2 Providing and fixing fibre mesh of 145 GSM weight in required width with cement mortar before plastering upto 10m height. 674 13.28 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 sand) : 13.28.1 Flush Band 13.28.2 Sunk Band 13.28.3 Raised Band 13.28.4 Moulded Band 675 13.29 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 sand): 13. 29.1 Flush Band 13. 29.2 Sunk Band 13. 29.3 Raised Band 13. 29.4 Moulded Band 676 13.30 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 sand) top layer 6mm thick with cement mortar 1:4(1 cement : 4 sand). 677 13.31 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 sand) : 13.31.1 Flush / Ruled/ Struck or weathered pointing. 13.31.2 Raised and cut pointing 13.31.3 Sunk pointing 678 13.32 Pointing on stone work with cement mortar 1:3 (1 cement: 3 sand). 13.32.1 Flush/ Ruled pointing 13.32.2 Raised and cut pointing 679 13.33 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3 marble dust) 680 13.34 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 sand): Flush/ Ruled pointing 681 13.35 Extra for pointing on walls on the outside/inside at height more than 10 metre from ground/floor level for every additional height of 3 m or part there of. 682 13.36 Providing and fixing broken glass in cement mortar 1.3 including cost of mortar, over compound walls. 683 13.37 Providing and fixing writing board green writing with chalk (regular modified polyster coated steel surface). of sizes. 13.37.1 size 1200mmx1800mm 13.37.2 size 1200mmx2400mm 13.37.3 size 1200mmx3000mm 684 13.38 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 685 13.39 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. 686 13.40 Extra for lining out plaster to imitate stone or concrete blocks walling. 687 13.41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. 688 13.42 Providing and applying special putty in two coats based materials varnish, Belgium chalk, turpentine oil, white paint, safeda including sand papering for making the surface smooth for applying any or vinyl paints including all cost of material and labouretc complete. 689 13.43 White washing with lime to give an even shade: New work (three or more coats) 690 13.44 Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. 691 13.45 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturers specification. Two or more coat on new work. 692 13.46 Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work 693 13.47 Distempering by any mechanical or manual means with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.47.1 One coat. 13.47.2 Two coats. 694 13.48 Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.48.1 One coat. 13.48.2 Two coats. 695 13.49 Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. 696 13.50 Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). 697 13.51 Finishing walls by only mechanical or manual means with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. 698 13.52 Finishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface 699 13.53 Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) 700 13.54 Finishing walls by any mechanical or manual means with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.54.1 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 13.54.2 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. 13.54.3 Two or more coats applied on walls @ 1.25 ltr/10 sqm. Over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm. 701 13.55 Painting with silicon and acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: 13.55.1 One coat 13.55.2 Two coats 702 13.56 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. 13.56.1 On steel work 13.56.2 On concrete work 703 13.57 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. 704 13.58 Applying a coat of mordant solution on G.S. sheet : 13.58.1 With a solution of 38 gms of copper acetate in a litre of soft water 13.58.2 With a solution made of 13 gms of hydrochloric acid in a solution of 13 gms each of copper chloride, copper nitrate and ammonium chloride dissolved in a litre of soft water. 705 13.59 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint approved brand and manufacture over and including a priming of ready mixed zinc chromate yellow primer on new work : 13.59.1 75 mm diameter pipes 13.59.2 100 mm diameter pipes 13.59.3 150 mm diameter pipes 706 13.60 Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 13.60.1 75 mm diameter pipes 13.60.2 100 mm diameter pipes 13.60.3 150 mm diameter pipes 707 13.61 Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats) 708 13.62 Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. 709 13.63 Coal tarring two coats on new work using 0.16 and 0.12 litre coal tar per sqm in the first coat and second coat respectively. 710 13.64 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 711 13.65 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 712 13.66 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.66.1 One coat. 13.66.2 Two coats. 713 13.67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 13.67.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. 13.67.2 With ready mixed red oxide zinc chromatic on steel/ iron works having VOC content less than 250 grams/litre. 13.67.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 714 13.68 Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work. 715 13.69 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work. 716 13.70 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 717 13.71 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work 718 13.72 Varnishing with varnish of approved brand and manufacture: 13.72.1 Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. 13.72.2 Two or more coats glue sizing with spar varnish or an under coat of flatting varnish. 719 13.73 French spirit polishing: Two or more coats on new works including a coat of wood filler. 720 13.74 Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work. 721 13.75 Lacqer polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying lacqer polish with air compressor. Two or more coats on new works including a coat of wood filler. 722 13.76 Mealamine polishing on door windows by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying mealamine polish with air compressor. Two or more coats on new works including a coat of wood filler. 723 13.77 Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. 724 13.78 Lettering with black Japan paint of approved brand and manufacture. 725 13.79 Providing and applying flakes textured homogeneous wall finishing system consisting of a two component system of dry flakes (9.5kgs per/pack) made of a special grade of heat treated China clay with rigid homopolymer coated with fade resistant pigments and a 100% acrylic polymer Bonding agent (5kgs/pack) applied thickness of the coating being between 0.8-1.2mm, to be applied in single coat, on a cured, smooth level plaster surface without keying, as per the shades/ combinations approved, as per manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per direction/ supervision of the engineers-in-charge inclusive of one coat of primer on the base at all heights etc all complete. 726 13.80 Providing and applying Granules homogeneous wall finishing system consisting of a two component system of dry granules (25 kgs/pack) made of 92% silica particles coated with fade resistant pigments and a 100% acrylic Polymer Bonding agent (5 kgs/pack) with the applied thickness of coating as required to be applied in single coat, on a cured. Smooth level plaster surface without keying as per the shades/combinations approved. As per the manufacturers directions for usage, to be applied by approved applicator of manufacturer, as per the directions/supervision of engineers in charge, all complete inclusive of primer on the base. 13.80.1 0.8-1.2mm thickness 13.80.2 2.0-2.5mm thickness 727 13.81 Providing and Applying Roto Wall finishing system being a dispersion of inorganic fillers, calcite, pure silica, quartz and broad spectrum fungicides stabilized by an acrylic co-polymer, to be applied by means of customized trowels (one for incorporating material on base and spreading and other for finishing) in single coat with a coating thickness of 2.0-2-2.5mm on a cured smooth level plaster without keying, by the approved applicator of manufacturer, of the approved shade as per directions for usage all inclusive including primer coat on the base. 728 13.82 Providing and plastering over AAC masonary wall with polymer modified cement based readymix factory controlled mortar with self curing, eco- friendly, wet premix in a mechanical mixer in thickness as specified below, and covering area of 2.04 kg per sqm/mm thickness. The Bulk density of ready mix plaster may vary from 1300 to 1600 Kg/cum, Water powder ratio (as per manufacture’s direction) may vary from 18-22 % by weight or as specified by the manufacturer and compressive strength may vary from 8-9 Mpa. 13.82.1 6 mm thick plaster for internal walls 13.82.2 8 mm thick plaster for external walls exposed to weather. 729 13.83 Providing and fixing including Designing and UV printing on aluminium composite material (ACM) sheet in different sizes with 720DPI (Dot per inch) 13.83.1 ACP sheet 2mm thick 13.83.2 ACP sheet 3mm thick 13.83.3 ACP sheet 4mm thick 730 13.84 Providing and fixing including designing and UV printing on pvc foam sheet of different size with 720 DPI (Dot per inch) 13.84.1 PVC foam sheet 3.0 mm thick 13.84.2 PVC foam sheet 5.0 mm thick 13.84.3 PVC foam sheet 8.0 mm thick 731 13.85 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 732 13.86 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board (XPS) of required size over outer wall surface, complying with ASTM C 578 - type VI, having thermal conductivity of 0.0289 W/mK as per ASTM and Fire retardant property as per DIN 4102, Part 1. XPS insulation of thickness 50mm shall be placed over brushed, algae free and levelled external wall by connecting the ship-laps joints and fixed by the washer and Self-Tapping Screw of suitable length at each corner and at distance 75mm from the edge and bitumen shall be applied over the joints and G.I. Expanded Mesh (Barfi Jali) shall be fixed over XPS board by a Self- Tapping Screw of suitable length at the centre of the board and 15mm PCC shall be applied over the board (paint of suitable choice can be used), all as per the directions of Engineer-in-Charge. 733 13.87 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorption < 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardant property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge. 734 13.88 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 735 13.89 Scrapping/sand papering of existing surface with the help of mechanized sanding machine (having mechanical vaccum machine with bag for dust collection to make surface even and smooth) as per direction of Engineer-in- Charge. 736 13.90 Providing and applying 1 coat of Triple booster primer-resist dampness, efflorescence, alkali & at the same time improve top coat coverage by 15-20% @1.0 lt/ 10 sqm, which confirms certfication of IS 109/1968. It can be applied by Brush/ Spray Machine and the work shall be carried out as per secification& the direction of the Engineer-in-Charge. 737 13.91 Finishing walls with water based anti- germ paint of with VOC < 50 g/l, that kills disease causing germs, teflon based washability and Anti fungal properties in two or more coats @ 1.08 ltr / 10 sqm over priming coat of interior primer applied @ 1.08 ltr / 10 sqm of required shade including removing of all dust complete as per direction of Engineer- in-Charge and submission of challans of materials on enquiry. 738 13.92 Providing and applying in two coats of 250 micron thick each layer of epoxy coating on prepared surface (cost includes preparing the plastered surface smooth ready to receive epoxy coating) for operation theater walls in desired colour as per direction of Engineer-in-Charge. 739 14.1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 sand). 740 14.2 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meters lead : 14.2.1 Door chowkhats 14.2.2 Window chowkhats 14.2.3 Clerestory window chowkhats 741 14.3 Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/ chemical fastener of appropriate size (3nos on each vertical member of door chowkhat and 2 nos. on each vertical member of window chowkhats) including cost of dash fasteners/ chemical fastener. 742 14.4 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish as directed by Engineer- in-charge. For door/ window/ clerestory window. 743 14.5 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm 14.5.2 Float glass panes of thickness 5.5 mm 744 14.6 Renewing glass panes with now wooden fillets wherever necessary: 14.6.1 Float glass panes of thickness 4 mm 14.6.2 Float glass panes of thickness 5.5 mm 745 14.7 Renewing glass panes and refixing existing wooden fillets: 14.7.1 Float glass panes of thickness 4 mm 14.7.2 Float glass panes of thickness 5.5 mm 746 14.8 Supplying and fixing new wooden fillets wherever necessary: 14.8.1 2nd class teak wood fillets 14.8.2 Haldu/Bija/Kail wood fillets. 747 14.9 Renewal of old putty of glass panes (length). 748 14.10 Refixing old glass panes with putty and nails. 749 14.11 Fixing old glass panes with wooden fillets (excluding cost of fillets). 750 14.12 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 751 14.13 Replacing sand stone slabs in roofing laid in cement mortar 1:4 (1 cement : 4 sand) including necessary repairs and cement pointing with same mortar complete including disposal of rubbish to dumping ground within 50 metres of lead : 14.13.1 Red/ white sand stone slabs 30 to 50 mm thick. 752 14.14 Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.14.1 Sal wood battens. 753 14.15 Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead : 14.15.1 Not exceeding 4.00 metres in length. 14.15.1.1 Sal wood beams 14.15.1.2 Haldu/Bija/Kail wood fillets. 14.15.2 Above 4.00 metres and upto 5.00 metres length. 14.15.2.1 Sal wood beams 14.15.2.2 Haldu/Bija/Kail wood fillets. 754 14.16 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground within 50 metres lead. 755 14.17 Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking. 756 14.18 Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand and manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand. 757 14.19 Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturer. 758 14.20 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. 14.20.1 Wheel 50 mm dia. and below. 14.20.2 Wheel above 50 mm dia. 759 14.21 Providing and fixing 25 mm thick shutters for cupboard etc. : 14.21.1 Panelled or panelled and glazed shutters : 14.21.1.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.1.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2 Glazed shutters : 14.21.2.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 14.21.2.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. 760 14.22 Providing and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10mm laths placed 35mm apart (frames to be paid separately) including fixing 50x12mm beading complete with: 14.22.1 Second class teak wood. 14.22.2 Hard wood, finger jointed 761 14.23 Providing and fixing curtain rods of 1.25mm thick brass plates with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 14.23.1 20 mm diameter. 14.23.2 25 mm diameter. 762 14.24 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. 763 14.25 Providing joists (karries) including hoisting fixing in position and applying wood preservative on unexposed surface etc. complete with: 14.25.1 Sal wood. 14.25.2 Haldu/Bija/Kail wood. 764 14.26 White washing with lime old work to give an even shade : 14.26.1 two or more coats 14.26.2 one or more coats 765 14.27 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 766 14.28 Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. 767 14.29 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: Old work (one or more coats). 768 14.30 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 769 14.31 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Old work (one or more coats). 770 14.32 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work : 14.32.1 75 mm diameter pipes 14.32.2 100 mm diameter pipes 14.32.3 150 mm diameter pipes 771 14.33 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with aluminium paint of approved brand and manufacture on old work : 14.33.1 75 mm diameter pipes 14.33.2 100 mm diameter pipes 14.33.3 150 mm diameter pipes 772 14.34 Painting (one or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : 14.34.1 75 mm diameter pipes 14.34.2 100 mm diameter pipes 14.34.3 150 mm diameter pipes 773 14.35 Painting with oil type wood preservative of approved brand and manufacture: Old work (one or more coats) 774 14.36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work. 775 14.37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 776 14.38 Painting with aluminium paint of approved brand and manufacture to give an even shade: One or more coats on old work. 777 14.39 Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. 778 14.40 Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: One or more coats on old work. 779 14.41 French spirit polishing: One or more coats on old work. 780 14.42 Mealamine polishing on wood work by preparing the surface applying putty base course. Prepare the surface smooth by sand papering and then applying Mealamine polish with air compressor. One or more coats on old work. 781 14.43 Lacquer polishing on wood work by preparing the surface applying putty base course. prepare the surface smooth by sand papering and then applying Lacquer polish with air compressor 14.43.1 One or more coats on old work. 782 14.44 Polishing on wood work with readymade wax polish of approved brand and manufacture : 14.44.1 Old work 783 14.45 Re-lettering with black Japan paint of approved brand and manufacture. 784 14.46 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. 785 14.47 Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin : 14.47.1 32 mm dia 14.47.2 40 mm dia 786 14.48 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. As per manufacturers specification. One or more coats on old work. 787 14.49 Finishing walls with water proofing cement paint of required shade : 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. 788 14.50 Finishing walls with textured exterior paint of required shade : 14.50.1 Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. 14.50.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm. 789 14.51 Finishing walls with Acrylic Smooth exterior paint of required shade : 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). 790 14.52 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). 791 14.53 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. 14.53.2 Painting wood work with Deluxe Multi Surface Paint of required shade. One or more coat applied @0.70 ltr/10 sqm 14.53.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. One or more coat applied @0.70 ltr/10 sqm. 792 14.54 Varnishing with varnish of approved brand and manufacture: 14.54.1 One or more coats with copal varnish. 14.54.2 One or more coats with spar varnish. 793 14.55 Melamine polishing on wood work (one or more coat). Old work 794 14.56 Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. 795 14.57 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade. One or more coat on old work. 796 14.58 40 mm thick stone flooring over 20 mm (average)thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone. Red sand stone / White sand stone) stone to be supplied by the department. 14.58.1 Rough chiseled dressed stone 14.58.2 Fine dressed stone 797 14.59 Coursed rubble masonry (second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 sand) (Stone shall be supplied by the department) 798 14.60 Laying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of sand, filling the joints with sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). 799 14.61 Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 sand) including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5mm) including making drainage opening wherever required etc. complete as per direction of Engineer-in- charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost). 800 14.62 Colour washing with lime to give an even shade: 14.62.1 (one or more coats) 14.62.2 (two or more coats) 801 14.63 Conducting adequate nos. of scanning to detect the steel reinforcement in existing RCC elements by using ground/ Wall penetrating radar system to avoid the cutting of Main bars during drilling for inserting bolts etc. complete. 802 14.64 Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. 803 14.70 Rebaring of TMT bars by drilling hole & embedding bars of different diameter using epoxy grouting compound including all tools and tackles complete. 14.70.1 8 mm dia bar 10 mm dia hole 14.70.2 10 mm dia bar 12 mm dia hole 14.70.3 12 mm dia bar 16 mm dia hole 14.70.4 16 mm dia bar 20 mm dia hole 14.70.5 20 mm dia bar 25 mm dia hole 14.70.6 25 mm dia bar 32 mm dia hole 14.70.7 32 mm dia bar 40 mm dia hole 804 14.71 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 14.71.1 125x70x4 mm (ordinary type) 14.71.2 100x70x4 mm (ordinary type) 14.71.3 75x65x4 mm (heavy type) 14.71.4 75x40x2.5 mm (ordinary type) 14.71.5 50x40x2.5 mm (ordinary type) 805 14.72 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. 806 14.73 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. 807 14.74 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of f tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in- Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 808 14.75 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer- incharge. 809 14.77 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 14.77.1 Bars upto 12 mm diameter 14.77.2 Bars above 12 mm diameter 810 14.78 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 14.78.1 Upto and including 12mm dia 811 14.83 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) 14.83.1 Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work 14.83.2 Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. 14.83.3 Epoxy injection grout in concrete/RCC work of approved make 812 14.85 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. 813 14.88 Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of L shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-incharge. 814 15.1 Demolishing lime concrete manually/by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-Charge. 815 15.2 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). 816 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 817 15.4 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. work (Payment shall be made on the cross sectional area of R.C.C. work) as per direction of Engineer-in- Charge. 818 15.5 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. work. 819 15.6 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. 820 15.6.1 In lime mortar with old mughal bricks. 15.6.2 In lime mortar. 15.6.3 In cement mortar. 821 15.7 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) : 15.7.1 From brick work in lime mortar. 15.7.2 From brick work in cement mortar. 822 15.8 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge: 15.8.1 In lime mortar. 15.8.2 In cement mortar. 823 15.9 Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge: 15.9.1 In lime mortar. 15.9.2 In cement mortar. 824 15.10 Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) : 15.10.1 In lime mortar. 15.10.2 In cement mortar. 825 15.11 Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead. 15.11.1 For thickness of tiles 10 mm to 25 mm. 15.11.2 For thickness of tiles above 25 mm and upto 40 mm. 826 15.12 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 827 15.13 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 828 15.14 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.14.1 Of area 3 sq. metres and below. 15.14.2 Of area beyond 3 sq. metres. 829 15.15 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: 15.15.1 Of area 3 sq. metres and below. 15.15.2 Of area beyond 3 sq. metres. 830 15.16 Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead: 15.16.1 Of sectional area below 40 square centimetres. 15.16.2 Of sectional area 40 square centimetres and above. 831 15.17 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 metres : 15.17.1 Of sectional area below 40 square centimetres. 15.17.2 Of sectional area 40 square centimetres and above. 832 15.18 Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one metre or part thereof beyond 5 metres : 15.18.2 Of sectional area below 40 square centimetres. 15.18.1 Of sectional area 40 square centimetres and above. 833 15.19 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: 15.19.1 R.S. Joists 15.19.2 Channels, angles, tees and flats 834 15.20 Dismantling steel work in built up sections with span upto 10 meter and hieght 5 meter in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. 835 15.21 Dismantling steel work manually/ by mechanical means in built up sections with span upto 10 meter and hieght 5 meter without dismembering and stacking within 50 metres lead as per direction of Engineer-in-Charge. 836 15.22 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one metre or part thereof beyond 10 metres 837 15.23 Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one metre or part thereof beyond 5 metres. 838 15.24 Extra for marking of structural steel work required to be re- erected. 839 15.25 Removal of old Tarfelt i/c disposal as directed by Engineer in charge. 840 15.26 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 841 15.27 Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: 15.27.1 G.S. Sheet 15.27.2 Asbestos/ Non asbestors sheet 842 15.28 Dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 843 15.29 Dismantling tiled roofing with battens boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 844 15.30 Dismantling wooden ballies in posts and struts including stacking within 50 metres lead. 845 15.31 Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : 15.31.1 T’ or ‘L’ iron or pipe 15.31.2 R.C.C. 846 15.32 Cutting ballies or wooden posts of fencing at the point of projection above the concrete or ground and stacking the same within 50 metres lead. 847 15.33 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 848 15.34 Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead. 849 15.35 Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. 850 15.36 Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 15.36.1 Upto 10 mm thick 15.36.2 Thickness above 10 mm upto 25 mm 15.36.3 Thickness above 25 mm upto 40 mm 851 15.37 Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead: 15.37.1 Thickness upto 40 mm 15.37.2 Thickness above 40 mm upto 75 mm 852 15.38 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. 853 15.39 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 15.39.1 75 to 80 mm dia pipe. 15.39.2 100 mm dia pipe 15.39.3 150 mm dia pipe 854 15.40 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-Charge : 15.40.1 15 mm to 40 mm nominal bore 15.40.2 Above 40 mm nominal bore 855 15.41 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes and lead at site within 50 metre lead as per direction of Engineer-in-Charge: 15.41.1 Upto 150 mm diameter 15.41.2 Above 150 mm dia upto 300 mm dia. 15.41.3 Above 300 mm diameter 856 15.42 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 857 15.43 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in- Charge. 858 15.44 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 859 15.45 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. 860 15.46 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres 15.46.1 Upto 150 mm diameter 15.46.2 Above 150 mm diameter 861 15.47 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. 862 15.48 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 863 15.49 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-Charge. 864 15.50 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps: 15.50.1 100 mm diameter 15.50.2 150 mm diameter 15.50.3 200 mm diameter 15.50.4 250 mm diameter 15.50.5 300 mm diameter 15.50.6 350 mm diameter 15.50.7 400 mm diameter 15.50.8 440 mm diameter 865 15.51 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead : 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep 866 15.52 Extra for depth of manholes dismantled: 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). 867 15.53 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground and stacking of serviceable material within 50 metre lead as per direction of Engineer-in- Charge. 868 15.54 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : 869 15.55 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. 870 15.56 Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 871 15.57 Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. 872 15.58 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge : 15.58.1 Water bound macadam road 15.58.2 Bituminous road 873 15.59 Dismantling steel cylinder R.C. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metres lead as per direction of Engineer-in-charge : 15.59.1 Up to 600 mm diameter 15.59.2 Above 600 mm diameter 874 15.60 Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually/ by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-charge 15.60.1 Up to 150 mm diameter 15.60.2 Above 150 mm diameter 875 15.61 Dismantling of R.C.C. spun vent shaft including excavating the cement concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the useful materials near the site and disposal of unserviceable materials within 50 metres lead. 876 15.62 Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead: 15.62.1 120 x 120 cm (outside to outside) 15.62.2 210 x 120 cm (outside to outside) 877 15.63 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in- charge. 878 15.64 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 879 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. 17.1.2 Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests. 880 17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid 17.2.3 Providing and fixing AISI-304 (18/8) European type WC instead of white vitreous china pedestal type water closet. 881 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. 882 17.4 Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat and lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required White vitreous china dual purpose WC pan with white solid plastic seat and lid with 10 liter low level flushing cistern i/c C.P. flush bend. 883 17.5 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 884 17.6 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.6.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern. 17.6.2 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. 17.6.3 Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern. 17.6.4 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. 885 17.7 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever require 17.7.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. 17.7.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. 17.7.3 Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern. 17.7.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. 886 17.8 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.8.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern. 17.8.2 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern. 17.8.3 Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern. 17.8.4 Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern. 887 17.9 Providing and fixing white vitreous china water less urinal of size 600x330x315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. 888 17.10 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge. 889 17.11 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.11.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. 17.11.6 White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap. 17.11.7 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap. 17.11.8 White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated lever ISI marked. 17.11.9 White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI marked. 17.11.10 Oval shape wash basin over counter /under counter with 15 mm C.P brass pillar tap (Counter to be paid sepratly). 17.11.11 Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap 17.11.12 Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap. 890 17.12 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 891 17.13 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 892 17.14 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. 17.14.1.2 510x1040 mm bowl depth 225mm. 17.14.1.3 510x1040 mm bowl depth 200mm. 17.14.1.4 510x1040 mm bowl depth 178mm. 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. 17.14.2.2 610x460 mm bowl depth 200 mm. 17.14.2.3 470x420 mm bowl depth 178 mm. 893 17.15 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required : 17.15.1 Size450x300x150mm 17.15.2 Size600x450x200mm 894 17.16 Providing and fixing White glazed fire clay draining board of size 600x450x25mm with C.I. brackets including painting of brackets, cutting and making good the walls wherever required. 895 17.17 Providing and fixing white vitreous china water closet squatting pan (Indian type) 17.17.1 Long pattern W.C. pan of size 580 mm 17.17.2 Orissa pattern W.C. pan of size 580x440 mm 896 17.18 Extra for using coloured W.C. pan instead of white W.C. pan Orissa pattern W.C. pan 580x440 mm 897 17.19 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 898 17.20 Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern. 899 17.21 Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet: 17.21.1 250x130x30 mm 17.21.2 250x125x25 mm 900 17.22 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity 17.22.1 White 17.22.2 coloured 901 17.23 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete.10 litre (full flush capacity) 17.23.1 White 17.23.2 Coloured 902 17.24 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : 17.24.1 White 17.24.2 Black 17.24.3 Coloured (other than black and white) 903 17.25 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. 904 17.26 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively. 905 17.27 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm. 906 17.28 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 907 17.29 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : 17.29.1 Flat back wash basin of size 630x450mm. 17.29.2 Flat back wash basin of size 550x400mm. 17.29.3 Angle back wash basin of size 600x480mm. 17.29.4 Angle back wash basin of size 400x400mm. 17.29.5 Flat back wash basin of size 450x300mm. 17.29.6 Surgeon type wash basin of size 660x460mm. 908 17.30 Providing and fixing kitchen sink including making all connections excluding cost of fittings. White glazed fire clay sink of size 600x450x250mm. 909 17.31 Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: 17.31.1 Size 450x300x150 mm. 17.31.2 Size 600x450x200 mm. 910 17.32 Providing and fixing soil, waste and vent pipes: 17.32.1 Sand cast iron socket and spigot (S&S) pipe as per IS: 1729 17.32.1.1 75 mm dia with wall thickness of 5 mm 17.32.1.2 100 mm dia with wall thickness of 5 mm 17.32.2 Spun cast iron socket and spigot (S&S) pipe as per IS: 3989 17.32.2.1 75 mm dia with wall thickness of 3.5 mm 17.32.2.2 100 mm dia with wall thickness of 4 mm 17.32.2.3 150mm dia with wall thickness of 5mm 17.32.3 Hubless Centrifugally cast (spun) iron pipe epoxy coated in side & out side including complete coupling assembly (EPDM rubber gasket stainless steel claim and external metallic/ protective shield as per IS:15905) 17.32.3.1 75 mm dia with wall thickness of 3.5 mm 17.32.3.2 100 mm dia with wall thickness of 3.5mm 17.32.3.3 150mm dia with wall thickness of 4 mm 911 17.33 Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 ( 1 cement : 2 sand) in S.C.I./ C.I. Pipes : 17.33.1 75 mm dia pipe 17.33.2 100 mm dia pipe 912 17.34 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : 17.34.1 For 75 mm dia pipe 17.34.2 For 100 mm dia pipe 17.34.3 For 150 mm dia pipe 913 17.35 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.35.1 150 mm dia 17.35.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.35.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.35.2 100 mm dia 17.35.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.35.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.35.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.35.3 75 mm dia 17.35.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5 mm 17.35.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.35.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 914 17.36 Providing and fixing plain bend of required degree. 17.36.1 150 mm dia 17.36.1.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.1.2 Spun cast iron as per IS – 3989 minimum wall thickness 5 mm 17.36.1.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3.5 mm 17.36.2 100 mm dia 17.36.2.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.2.2 Spun cast iron as per IS – 3989 minimum wall thickness 4 mm 17.36.2.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 17.36.3 75 mm dia 17.36.3.1 Sand cast iron as per IS – 1729 minimum wall thickness 6.5mm 17.36.3.2 Spun cast iron as per IS – 3989 minimum wall thickness 3.5 mm 17.36.3.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 3 mm 915 17.37 Providing and fixing heel rest sanitary bend 17.37.1 100 mm dia 17.37.1.1 Sand cast iron as per IS - 1729 17.37.1.2 Spun cast iron as per IS - 3989 17.37.2 75 mm dia 17.37.2.1 Sand cast iron as per IS - 1729 17.37.2.2 Spun cast iron as per IS - 3989 916 17.38 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 17.38.1.1 150X150X150X150 17.38.1.2 Sand cast iron as per IS - 3989 17.38.2 100x100x100x100mm 17.38.2.1 Sand cast iron as per IS - 1729 17.38.2.2 Spun cast iron as per IS - 3989 17.38.3 75x75x75x75mm 17.38.3.1 Sand cast iron as per IS - 1729 17.38.3.2 Spun cast iron as per IS - 3989 917 17.39 Providing and fixing double equal plain junction of required degree. 17.39.1 150X150X150X150 mm 17.39.1.1 Sand cast iron as per IS - 3989 17.39.2 100x100x100x100mm 17.39.2.1 Sand cast iron as per IS – 1729 17.39.2.2 Spun cast iron as per IS – 3989 17.39.2.3 Hubless cast(spun) iron as per IS- 15905 17.39.3 75x75x75x75 mm 17.39.3.1 Sand cast iron as per IS – 1729 17.39.3.2 Spun cast iron as per IS – 3989 17.39.3.3 Hubless cast(spun) iron as per IS- 15905 918 17.40 Providing and fixing single equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.40.1 150X150X150 mm 17.40.1.1 Spun cast iron as per IS - 3989 17.40.2 100x100x100 mm 17.40.2.1 Sand cast iron as per IS - 1729 17.40.2.2 Spun cast iron as per IS - 3989 17.40.3 75x75x75 mm 17.40.3.1 Sand cast iron as per IS - 1729 17.40.3.2 Spun cast iron as per IS - 3989 919 17.41 Providing and fixing single equal plain junction of required degree : 17.41.1 150X150X150 mm 17.41.1.1 Spun cast iron as per IS - 3989 17.41.2 100x100x100 mm 17.41.2.1 Sand cast iron as per IS – 1729 17.41.2.2 Spun cast iron as per IS – 3989 17.41.2.3 Hubless cast(spun) iron as per IS- 15905 17.41.3 75x75x75 mm 17.41.3.1 Sand cast iron as per IS – 1729 17.41.3.2 Spun cast iron as per IS – 3989 17.41.3.3 Hubless cast(spun) iron as per IS- 15905 920 17.42 Providing and fixing double unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75x75 mm 17.42.1 Sand cast iron as per IS - 1729 17.42.2 Spun cast iron as per IS - 3989 921 17.43 Providing and fixing double unequal plain junction of required degree: 100x100x75x75 mm 17.43.1.1 Sand cast iron as per IS – 1729 17.43.1.2 Spun cast iron as per IS – 3989 17.43.1.3 Hubless cast(spun) iron as per IS- 15905 922 17.44 Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75 mm 17.44.1 Sand cast iron as per IS - 1729 17.44.2 Spun cast iron as per IS - 3989 923 17.45 Providing and fixing single unequal plain junction of required degree : 100x100x75 mm 17.45.1 Sand cast iron as per IS – 1729 17.45.2 Spun cast iron as per IS – 3989 17.45.3 Hubless cast(spun) iron as per IS- 15905 924 17.46 Providing and fixing double equal plain invert branch of required degree: 17.46.1 100x100x100x100 mm 17.46.1.1 Sand cast iron as per IS - 1729 17.46.1.2 Sand cast iron as per IS - 3989 17.46.1.3 Hubless cast(spun) iron as per IS- 15905 17.46.2 75x75x75x75 mm 17.46.2.1 Sand cast iron as per IS - 1729 17.46.2.2 Spun cast iron as per IS - 3989 925 17.47 Providing and fixing single equal plain invert branch of required degree: 17.47.1 100x100x100 mm 17.47.1.1 Sand cast iron as per IS - 1729 17.47.1.2 Sand cast iron as per IS - 3989 17.47.1.3 Hubless cast(spun) iron as per IS- 15905 17.47.2 75x75x75 mm 17.47.2.1 Sand cast iron as per IS - 1729 17.47.2.2 Sand cast iron as per IS - 3989 17.47.2.3 Hubless cast(spun) iron as per IS- 15905 926 17.48 Providing and fixing double unequal invert branch of required degree : 100x100x75x75 mm 17.48.1 Sand cast iron as per IS - 1729 17.48.2 Spun cast iron as per IS - 3989 927 17.49 Providing and fixing single unequal plain invert branch of required degree : 100x100x75 mm 17.49.1 Sand cast iron as per IS - 1729 17.49.2 Spun cast iron as per IS - 3989 17.49.3 Hubless cast(spun) iron as per IS- 15905 minimum wall thickness 928 17.50 Providing and fixing sand cast iron S&S off sets as per IS: 1729 17.50.1 76 mm off sets 17.50.1.1 With 75 mm dia pipe 17.50.1.2 With 100 mm dia pipe 17.50.2 114 mm off sets 17.50.2.1 With 75 mm dia pipe 17.50.2.2 With 100 mm dia pipe 17.50.3 152 mm off sets 17.50.3.1 With 75 mm dia pipe 17.50.3.2 With 100 mm dia pipe 929 17.51 Providing and fixing sand cast iron S&S off sets as per IS: 3989. 17.51.1 75 mm off sets 17.51.1.1 With 75 mm dia pipe 17.51.1.2 With 100 mm dia pipe 17.51.1.3 With 150 mm dia pipe 17.51.2 150 mm off sets 17.51.2.1 With 75 mm dia pipe 17.51.2.2 With 100 mm dia pipe 17.51.2.3 With 150 mm dia pipe 930 17.52 Providing and fixing door piece, insertion rubber washer 3mm thick, bolts and nuts complete : 17.52.1 100 mm 17.52.1.1 Sand cast iron as per IS - 1729 17.52.1.2 Spun cast iron as per IS - 3989 17.52.2 75 mm 17.52.2.1 Sand cast iron as per IS - 1729 17.52.2.2 Spun cast iron as per IS - 3989 931 17.53 Providing and fixing terminal guard: 17.53.1 150mm 17.53.1.1 Sand cast iron as per IS - 1729 17.53.1.2 Spun cast iron as per IS - 3989 17.53.1.3 Hubless cast(spun) iron as per IS- 15905 17.53.2 100 mm 17.53.2.1 Sand cast iron as per IS - 1729 17.53.2.2 Spun cast iron as per IS - 3989 17.35.2.3 Hubless cast(spun) iron as per IS-15905 17.53.3 75 mm 17.53.3.1 Sand cast iron as per IS - 1729 17.53.3.2 Spun cast iron as per IS - 3989 17.53.3.3 Hubless cast(spun) iron as per IS- 15905 932 17.54 Providing and fixing collar: 17.54.1 100 mm 17.54.1.1 Sand cast iron S & S as per IS - 1729 17.54.1.2 Sand cast iron S & S as per IS - 3989 17.54.2 75 mm 17.54.2.1 Sand cast iron S & S as per IS - 1729 17.54.2.2 Sand cast iron S & S as per IS- 3989 933 17.55 Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter: 17.55.1 150mm 17.55.2 100 mm 17.55.3 75 mm 934 17.56 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 17.56.1 100 mm dia 17.56.2 75 mm dia 935 17.57 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.57.1 100 mm inlet and 100 mm outlet 17.57.1.1 Spun cast iron S & S as per IS: 3989. 17.57.1.2 Sand Cast iron S & S as per IS: 1729. 17.57.1.3 Hubless cast(spun) iron as per IS-15905 17.57.2 100 mm inlet and 75 mm outlet 17.57.2.1 Sand cast iron S & S as per IS - 3989 17.57.2.2 Spun Cast iron S & S as per IS- 1729. 17.57.2.3 Hubless cast(spun) iron as per IS- 15905 936 17.58 Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 17.58.1 75 mm diameter 17.58.2 110 mm diameter 937 17.59 Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 17.59.1 Coupler 17.59.1.1 75 mm 17.59.1.2 110 mm 17.59.2 Single pushfit Coupler 17.59.2.1 75 mm 17.59.2.2 110 mm 17.59.3 Single tee with door 17.59.3.1 75x75x75 mm 17.59.3.2 110x110x110 mm 17.59.4 Single tee without door 17.59.4.1 75x75x75 mm 17.59.4.2 110x110x110 mm 17.59.5 Bend 87.50 17.59.5.1 75 mm bend 17.59.5.2 110 mm bend 938 17.60 Providing and fixing Unplasticised - PVC pipe clips of approved design to Unplasticised - PVC soil and waste pipes by means of bombay nail of required length including and making good the wall etc. complete. 17.60.1 75 mm 17.60.2 110 mm 939 17.61 Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet 940 17.62 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x1.6mm galvanised M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts, bolts, and washers of size 25x6mm, one bolts on each side of the pipe. 17.62.1 Total bracket length 580mm of approved shape and design (for single, 100mm dia pipe). 17.62.2 Total bracket length 810mm of approved shape and design (for two, 100mm dia pipes). 17.62.3 Total bracket length 1040mm of approved shape and design (for three, 100mm dia pipes). 941 17.63 Cutting chases in brick masonry walls (clay brick/flyash brick/AAC blocks) for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 sand :6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 sand) : 17.63.1 100 mm dia 17.63.2 75 mm dia 17.63.3 50 mm dia 942 17.64 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia 17.64.1.2 40 mm dia 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia 17.64.2.2 40 mm dia 943 17.65 Providing and fixing 100 mm sand cast Iron grating for gully trap. 944 17.66 Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design. 945 17.67 Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 946 17.68 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6 mm thick hard board backing 17.68.1 Circular shape 450mm dia. 17.68.2 Rectangular shape 453x357mm 17.68.3 Oval shape 450x350mm (outer dimensions) 17.68.4 Rectangular shape 1500x450 mm 947 17.69 Providing and fixing glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 948 17.70 Providing and fixing toilet paper holder: 17.70.1 C.P. brass 17.70.2 Vitreous china 949 17.71 Providing and fixing CP brass waste coupling of approved quality and make for sink and wash basin. 17.71.1 Waste coupling 31mm of 79mm length and 62mm breadth 17.71.2 Waste coupling 38mm of 83mm length and 77mm breadth 950 17.72 Providing and fixing CP brass bottle trap of approved quality and make for sink and wash basin. 951 17.73 Providing and fixing CP brass towel rail of approved quality and make 17.73.1 600x20mm 17.73.2 450x20mm 952 17.74 Providing and fixing CP brass towel ring of approved quality and make 200mm dia ring 953 17.75 Providing and fixing CP brass soap dish of approved quality and make 954 17.76 Providing and fixing CP brass Urinal spreader of approved quality and make 955 17.77 Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall of standard shape with bracket of the same material with all fittings etc. of approved quality and conforming to IS: specification. 956 17.78 Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 17.78.1 100 mm dia. 957 17.79 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.79.1 Waste coupling 31mm dia of 79mm length and 62mm breadth weighing not less than 45gms. 17.79.2 Waste coupling 38mm dia of 83mm length and 77mm breadth, weighing not less than 60gms. 958 17.80 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.80.1 Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 260gms. 17.80.2 Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighting not less than 263gms. 959 17.81 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. Weighing not less than 105 gms. 960 17.82 Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colour. Weighing not less than 88 gms. 961 17.83 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 17.83.1 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. 17.83.2 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. 962 17.84 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. 963 17.85 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 964 17.86 Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. 965 17.87 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 966 17.88 Painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint over a coat of zinc chromate yellow primer (of approved quality) on the outside surface of the cistern, flush pipe, other fittings, etc. complete for new work. 967 17.89 Re-painting C.I. cistern with bitumastic or any other anti-corrosive paint inside and white paint on the outside surface of the cistern, flush pipe, other fittings, etc. complete including polishing of wooden seat and lid and cleaning of W.C. pan with acid wherever necessary. 968 17.90 Repainting C.I. cistern with synthetic enamel paint of approved colour brand and manufacture on the outside surface of cistern flush pipe, other fittings etc. complete. 969 17.91 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 17.91.1 75 mm diameter pipe 17.91.2 100 mm diameter pipe 17.91.3 150 mm diameter pipe 970 17.92 Repainting sand cast iron/ centrifugally cast iron (spun) iron, soil, waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as chocolate, grey or buff etc : 17.92.1 75 mm diameter pipe 17.92.2 100 mm diameter pipe 17.92.3 150 mm diameter pipe 971 17.93 Repainting bath tub of size 1700x730x430mm with enamel paint. 972 17.94 Providing and laying Ceramic glazed half round pipe drain (having thickness 9 to 10mm) of approved make in colours such as White, Ivory, Grey, or any other colour, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. 17.94.1 100 mm dia half round pipe 17.94.2 150 mm dia half round pipe 17.94.3 200mm dia half round pipe 973 17.99 Construction of manually operated fire based incinerator for girls-toilet i/c (i)   Fire and ash collection chamber 0.60x0.60 m, made of calcium silicate bricks, having 12mm dia steel bars grating @10 cm c/c, i/c MS mesh weldedon top including 300 mm x 450 mm MS openable door of half grill and half MS plate (3mm thick ).(ii)     0.40 m X 0.40 m duct made of 1.6 mm thick MS sheet for dropping napkins from the toilet opening.(iv) 150mm dia Class C heavy duty MS pipe conforming to IS 3589/1239 for gas emission with cowel, up to 2.10 meter height above terrace level.(v) Opening in wall having MS flap (1.6mm thick) of size 0.25X 0.25 m, finished with granite.etc complete as per standard drawing no. 5313-B-NB4-9919- R1 dated 21.02.2017 17.99.1 For ground floor buildings. 17.99.2 For Ground floor & Ist floor buildings. 17.99.3 Add extra for every additional floor above Ist floor. 974 17.95 Providing and fixing coupler for PVC pipes & fittings waste/rain water/drainage disposal of superior Indian make (as approved by Engineer incharge) i/c jointing with rubber rings, adhesive, lubricant,solvent cement PVC clips or burried underground i/c making necessary chases and holes in walls, floors or trenching complete with making good or i/c excavation and refilling as per site requirement with testing etc.complete. FOR WASH BASIN CONNECTION (40mm diameter) 975 18.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia Pipes. 18.6.1.2 20 mm nominal outer dia .Pipes. 18.6.1.3 25 mm nominal outer dia .Pipes. 18.6.1.4 32 mm nominal outer dia Pipes. 18.6.1.5 40 mm nominal outer dia Pipes. 18.6.1.6 50 mm nominal outer dia .Pipes. 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes. 18.6.2.2 20 mm nominal outer dia .Pipes. 18.6.2.3 25 mm nominal outer dia Pipes. 18.6.2.4 32 mm nominal outer dia Pipes. 976 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work 18.7.1 15 mm nominal outer dia Pipes. 18.7.2 20 mm nominal outer dia .Pipes. 18.7.3 25 mm nominal outer dia Pipes. 18.7.4 32 mm nominal outer dia .Pipes. 18.7.5 40 mm nominal outer dia Pipes. 18.7.6 50 mm nominal outer dia .Pipes. 18.7.7 62.50 mm nominal inner dia Pipes. 18.7.8 75 mm nominal inner dia .Pipes. 18.7.9 100mm nominal inner dia .Pipes. 18.7.10 150 mm nominal inner dia Pipes. 977 18.8 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 18.8.1 Internal work - Exposed on wall 18.8.1.1 15 mm dia. nominal bore 18.8.1.2 20 mm dia. nominal bore 18.8.1.3 25 mm dia. nominal bore 18.8.1.4 32 mm dia. nominal bore 18.8.1.5 40 mm dia. nominal bore 18.8.1.6 50 mm dia. nominal bore 18.8.2 Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall. 18.8.2.1 15 mm dia nominal bore 18.8.2.2 20 mm dia nominal bore 18.8.3 External work : including trenching and refilling etc. 18.8.3.1 15 mm dia. nominal bore 18.8.3.2 20 mm dia. nominal bore 18.8.3.3 25 mm dia. nominal bore 18.8.3.4 32 mm dia. nominal bore 18.8.3.5 40 mm dia. nominal bore 18.8.3.6 50 mm dia. nominal bore 18.8.3.7 65 mm dia. nominal bore 18.8.3.8 80 mm dia. nominal bore 978 18.9 Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment) 18.9.1 Internal work - Exposed on wall 18.9.1.1 15.88 mm outer diapipe 18.9. 1.2 22.22 mm outer diapipe 18.9.1.3 28.58 mm outer diapipe 18.9.1.4 34.00 mm outer dia Pipe 18.9.1.5 42.70 mm outer dia Pipe 18.9.1.6 48.60 mm outer dia Pipe 18.9.2 Internal work - Concealed Pipe 18.9.2.1 15.88 mm outer dia .Pipes. 18.9.2.2 22.22 mm Outer diaPipes 979 18.12 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.12.1 With C.I. wheel of approved quality (screwed end) 18.12.1.1 25 mm nominal bore 18.12.1.2 32 mm nominal bore. 18.12.1.3 40 mm nominal bore 18.12.1.4 50 mm nominal bore 18.12.1.5 65 mm nominal bore 18.12.1.6 80 mm nominal bore 18.12.2 With brass lever handle of approved quality. 18.12.2.1 25 mm nominal bore 18.12.2.2 32 mm nominal bore. 18.12.2.3 40 mm nominal bore 18.12.2.4 50 mm nominal bore 980 18.13 Providing and fixing CPVC gate valve with knob of approved quality. 18.13.1 25 mm nominal bore 18.13.2 32 mm nominal bore. 18.13.3 40 mm nominal bore 18.13.4 50 mm nominal bore 981 18.14 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.14.1 15 mm nominal bore 18.14.2 20 mm nominal bore 18.14 3 25 mm nominal bore 982 18.15 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.15.1 25 mm nominal bore 18.15.1.1 Horizontal 18.15.1.2 Vertical 18.15.2 32 mm nominal bore 18.15.2.1 Horizontal 18.15.2.2 Vertical 18.15.3 40 mm nominal bore 18.15.3.1 Horizontal 18.15.3.2 Vertical 18.15.4 50 mm nominal bore 18.15.4.1 Horizontal 18.15.4.2 Vertical 18.15.5 65 mm nominal bore 18.15.5.1 Horizontal 18.15.5.2 Vertical 18.15.6 80 mm nominal bore 18.15.6.1 Horizontal 18.15.6.2 Vertical 983 18.16 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.16.1 15 mm nominal bore 18.16.2 20 mm nominal bore 18.16.3 25 mm nominal bore 984 18.17 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore 18.17.1.2 20 mm nominal bore 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore 18.17.2.2 20 mm nominal bore 985 18.18 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :- 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. 986 18.19 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design 18.19.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.19.2 With flyash bricks of 50 kg/cm2 strength 987 18.20 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.20.1 With common burnt clay bricks of 25 kg/cm2 compressive strength. 18.20.2 With flyash bricks of 50kg/cm2 strength. 988 18.21 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 18.21.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.21.2 With flyash bricks of 50kg/sqm compressive strength. 989 18.22 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 18.22.1 15 mm diameter pipe. 18.22.2 20 mm diameter pipe. 18.22.3 25 mm diameter pipe. 18.22.4 32 mm diameter pipe. 18.22.5 40 mm diameter pipe. 18.22.6 50 mm diameter pipe. 990 18.23 Repainting G.I. pipes and fittings with synthetic enamel white paint of approved quality : 18.23.1 15 mm diameter pipe. 18.23.2 20 mm diameter pipe. 18.23.3 25 mm diameter pipe 18.23.4 32 mm diameter pipe 18.23.5 40 mm diameter pipe 18.23.6 50 mm diameter pipe 991 18.24 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 18.24.1 15 mm diameter pipe 18.24.2 20 mm diameter pipe 18.24.3 25 mm diameter pipe 18.24.4 32 mm diameter pipe 18.24.5 40 mm diameter pipe 18.24.6 50 mm diameter pipe 18.24.7 65 mm diameter pipe 18.24.8 80 mm diameter pipe 992 18.25 Providing and filling sand all-round the G.I. pipes in external work. 18.25.1 15 mm diameter pipe 18.25.2 20 mm diameter pipe 18.25.3 25 mm diameter pipe 18.25.4 32 mm diameter pipe 18.25.5 40 mm diameter pipe 18.25.6 50 mm diameter pipe 18.25.7 65 mm diameter pipe 18.25.8 80 mm diameter pipe 993 18.26 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 18.26.1 15 mm nominal bore 18.26.2 20 mm nominal bore 18.26.3 25 mm nominal bore 18.26.4 32 mm nominal bore 18.26.5 40 mm nominal bore 18.26.6 50mm nominal bore 18.26.7 65mm nominal bore 18.26.8 80 mm nominal bore 994 18.27 Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 18.27.1 15 mm nominal bore. 18.27.2 20 mm nominal bore. 18.27.3 25 mm nominal bore. 18.27.4 32 mm nominal bore. 18.27.5 40 mm nominal bore. 18.27.6 50 mm nominal bore. 18.27.7 65 mm nominal bore. 18.27.8 80 mm nominal bore. 995 18.28 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 996 18.29 Providing and fixing brass bib cock of approved quality 18.29.1 15 mm nominal bore 18.29.2 20 mm nominal bore 997 18.30 Providing and fixing brass stop cock of approved quality : 18.30.1 15 mm nominal bore 18.30.2 20 mm nominal bore 998 18.31 Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, and weighing not less then 400 kg, 15 mm nominal bore. 999 18.32 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. 1000 18.33 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal bore 1001 18.34 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. 1002 18.35 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore 1003 18.36 Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore. 1004 18.37 Providing and fixing C.P. brass pillar cock approved quality and make conforming to IS: specification. nd weighing not less than 650 gm,a15 mm nominal bore 125 mm long foam flow. 1005 18.38 Providing and fixing C.P. brass basin mixer of approved quality and make conforming to IS: specification.15 mm nominal bore. 1006 18.39 Providing and fixing C.P. brass wall mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1007 18.40 Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1008 18.41 Providing and fixing C.P. brass elbow operated bibcock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1009 18.42 Providing and fixing C.P. brass elbow operated pillar cock of approved quality and make conforming to IS: specification. 15 mm nominal bore. 1010 18.43 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.43.1 100 mm diameter 18.43.2 150 mm diameter 18.43.3 200 mm diameter 1011 18.44 Providing and fixing PTMT bib cock of approved quality and colour 15mm nominal bore. 18.44.1 86 mm long weighing not less than 88 gm 18.44.2 122 mm long weighing not less than 99 gm 18.44.3 165mm long weighing not less than 110 gm 18.44.4 90mm long weighing not less than 93 gm 1012 18.45 Providing and fixing PTMT stop cock of approved quality and colour. 18.45.1 15 mm nominal bore, 86mm long. Weighing not less than 88 gms. 18.45.2 20mm nominal bore, 89mm long. Weighing not less than 88 gms. 18.45.3 Concealed stop cock, 15mm nominal bore, 108mm long. Weighing not less than 108 gms. 1013 18.46 Providing and fixing PTMT pillar cock of approved quality and colour. 18.46.1 15mm nominal bore, 107mm long. Weighing not less than 110 gms. 18.46.2 15mm nominal bore, 125mm long foam flow weighing not less than 120 gms. 1014 18.47 Providing and fixing PTMT, push cock of approved quality and colour. 18.47.1 15 mm nominal bore, 98mm long. Weighing not less than 75 gms. 18.47.2 15 mm nominal bore, 80mm long weighing not less than 46 gms. 1015 18.48 Providing and fixing PTMT grating of approved quality and colour. 18.48.1 Circular type. 18.48.1.1 100 mm nominal dia. 18.48.1.2 125 mm nominal dia with 25 mm waste hole. 18.48.2 Rectangular type with openable circular lid. 18.48.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating. 1016 18.49 Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. 1017 18.50 Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40gms. 1018 18.51 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 18.51.1 15 mm nominal bore, 105 mm long. Weighing not less than 138 gms. 18.51.2 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 18.51.3 25 mm nominal bore, 152mm long. Weighing not less than 440 gms. 18.51.4 40mm nominal bore, 206mm long. Weighing not less than 690 gms. 18.51.5 50mm nominal bore, 242mm long. Weighing not less than 1240 gms. 1019 18.52 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour 15 mm nominal bore 18.52.1 30cm length. 18.52.2 45 cm length. 1020 18.53 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 18.53.1 15 mm nominal bore.Weighing not less than 32 gms. 18.53.2 20mm nominal bore.Weighing not less than 40gms. 18.53.3 25mm nominal bore.Weighing not less than 62 gms. 1021 18.54 Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 18.54.1 80 mm nominal bore 18.54.2 100 mm nominal bore 18.54.3 150 mm nominal bore 18.54.4 200 mm nominal bore 1022 18.55 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 18.55.1 80 mm nominal bore 18.55.2 100 mm nominal bore 18.55.3 150 mm nominal bore 18.55.4 200 mm nominal bore 1023 18.56 Cutting holes upto 30x30 cm in walls including making good the same : With common burnt clay bricks of 25 kg /sqcmor flyash bricks of 50 kg/cm2compressive strength. 1024 18.57 Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. 1025 18.58 Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. 1026 18.59 Making hole upto 20x20 cm and embedding pipes upto 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) including disposal of malba. 1027 18.60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.60.1 25 to 40 mm nominal bore 18.60.2 50 to 80 mm nominal bore 1028 18.61 Providing and fixing CP jet assembly to including connection etc complete. 1029 18.62 Providing and fixing ferro- cement water storage tank with cover, having minimum thickness of 10mm. The wall to be reinforced with two layers of double galvanized annealed square wooven wire mesh of 20 gauge wire spaced at 15mm for 300 litre capacity and 12mm for 450 to 2500 litres capacity finish with 3 layers of Cement mortar 1:2 duly modified with polymer based plastizers and hardening chemicals (Burogrout and Buroseal) The tank should conform to the specification prescribed by Structural Engineering Research Centre Roorkee/Gaziabad. The tanks to be painted with drinking water paint inside and aluminimum paint out side with provision of outlet, inlet, overflow and cleaning including hoisting and placing in position upto floor two level or 5 M. height. 1030 18.63 Add extra for additional floor lift beyond 5.0M.height. 1031 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.1.1 100 mm diameter 19.1.2 150 mm diameter 19.1.3 200 mm diameter 19.1.4 230 mm diameter 19.1.5 250 mm diameter 19.1.6 300 mm diameter 1032 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 19.2.1 100 mm diameter S.W. pipe 19.2.2 150 mm diameter S.W. pipe 19.2.3 200 mm diameter S.W. pipe 19.2.4 230 mm diameter S.W. pipe 19.2.5 250 mm diameter S.W. pipe 19.2.6 300 mm diameter S.W. pipe 1033 19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design : 19.3.1 100 mm diameter S.W. pipe 19.3.2 150 mm diameter S.W. pipe 19.3.3 200 mm diameter S.W. pipe 19.3.4 230 mm diameter S.W. pipe 19.3.5 250 mm diameter S.W. pipe 19.3.6 300 mm diameter S.W. pipe 1034 19.4 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) 19.4.2 160 mm diameter OD (min. wall thickness 4.0mm) 19.4.3 200 mm diameter OD (min. wall thickness 4.9mm) 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) 1035 19.5 Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 19.5.1 110 mm diameter PVC. pipe 19.5.2 160 mm diameter PVC. pipe 19.5.3 200 mm diameter PVC. pipe 19.5.4 250 mm diameter PVC. pipe 19.5.5 300 mm diameter PVC pipe 1036 19.6 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) up to haunches of PVC. pipes including bed concrete as per standard design : 19.6.1 110 mm diameter PVC. pipe 19.6.2 160 mm diameter PVC. pipe 19.6.3 200 mm diameter PVC. pipe 19.6.4 250 mm diameter PVC. Pipe 19.6.5 300 mm diameter PVC pipe 1037 19.7 Providing and fixing square- mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks 19.7.1.2 With Sewer bricks conforming to IS : 4885 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks 19.7.2.2 With sewer bricks conforming to IS : 4885 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks 19.7.3.2 With Sewer bricks conforming to IS : 4885 1038 19.8 Providing and laying non- pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 19.8.1 100 mm dia. R.C.C. pipe 19.8.2 150 mm dia. R.C.C. pipe 19.8.3 250 mm dia. R.C.C. pipe 19.8.4 300 mm dia. R.C.C. pipe 19.8.5 450 mm dia. R.C.C. pipe 19.8.6 500 mm dia. R.C.C. pipe 19.8.7 600 mm dia. R.C.C. pipe 1039 19.9 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks 19.9.1.2 With Sewer bricks conforming to IS : 4885 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 19.9.2.1 With well burnt bricks 19.9.2.2 With Sewer bricks conforming to IS : 4885 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : 19.9.3.1 With well burnt bricks 19.9.3.2 With Sewer bricks conforming to IS : 4885 1040 19.10 Extra for depth for manholes 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks 19.10.1.2 With Sewer bricks conforming to IS : 4885 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks 19.10.2.2 With Sewer bricks conforming to IS : 4885 1041 19.11 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 19.11.1 With well burnt bricks 19.11.2 With Sewer bricks conforming to IS : 4885 1042 19.12 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91m to 1.67m 19.12.1 With well burnt bricks 19.12.2 With Sewer bricks conforming IS : 4885 1043 19.13 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) 19.13.1 With well burnt bricks 19.13.2 With Sewer bricks conforming IS : 4885 1044 19.14 Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : 19.14.1 With well burnt bricks 19.14.2 With Sewer bricks conforming IS : 4885 1045 19.15 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design : 19.15.1 2.30m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (Foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.15.1.1 With well burnt bricks 19.15.1.2 With Sewer bricks conforming IS : 4885 1046 19.16 Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : 19.16.1 With well burnt bricks 19.16.2 With Sewer bricks conforming IS : 4885 1047 19.17 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 19.17.1 With 20x20 mm square bar 19.17.2 With 20 mm diameter round bar 1048 19.18 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 1049 19.19 Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size): 19.19.1 With 20x20 mm square bar 19.19.2 With 20 mm diameter round bar 1050 19.20 Supplying and fixing C.I. cover without frame for manholes : 19.20.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. 19.20.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. 19.20.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg. 1051 19.21 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality 19.21.1 Light duty D- 2.5 19.21.1.1 Rectangular shape 600x450mm internal dimensions 19.21.1.2 Square shape 450mm internal dimensions 19.21.1.3 Circular shape 450mm internal diameter 19.21.2 Medium duty - 10 19.21.2.1 Square shape 450mm internal dimension 19.21.2.2 Circular shape 500mm internal diameter 19.21.3 Heavy duty D - 20 19.21.3.1 Circular shape 560 mm internal diameter 19.21.4 Extra Heavy Duty - 35 19.21.4.1 Circular shape 560 mm internal dia. 1052 19.22 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg. 1053 19.23 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 19.23.1 For pipes 100 to 230 mm diameter 19.23.2 For pipes 250 to 300 mm diameter 19.23.3 For pipes 350 to 450 mm diameter 1054 19.24 Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with cement mortar 1:1 (1 cement : 1 sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications : 19.24.1 100 mm dia. sand cast iron drop connection 19.24.2 150 mm dia. sand cast iron drop connection 1055 19.25 Extra for depths beyond 60 cm of sand cast iron drop connection complete : 19.25.1 For 100 mm dia. sand cast iron drop connection 19.25.2 For 150 mm dia. sand cast iron drop connection 1056 19.26 Raising manhole cover and frame slab to required level including dismantling existing slab and making good the damage as required (Brick work for Raising depth of manhole to be paid separately) : 19.26.1 Rectangular manhole 90x80 cm with rectangular cover 600x450 mm of grade LD - 2.5 19.26.2 Rectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 10 19.26.3 Rectangular manhole 120x90 cm with circular cover 560 mm dia of grade HD - 20 19.26.4 Circular manhole 140 cm dia with circular cover 600 mm dia of grade Extra heavy duty HD -35 1057 19.27 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With well burnt bricks 19.27.2 With fly ash bricks 100 key/cm2 strangth 1058 19.28 Constructing brick masonry road gully chamber 45x45x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With well burnt bricks 19.28.2 With fly ash bricks 100 kg/cm2 strength 1059 19.29 Constructing brick masonry road gully chamber 110x50x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : 19.29.1 With well burnt bricks 19.29.2 With fly ash bricks 100 kg/cm2 strength 1060 19.30 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.30.1 With well burnt bricks 1061 19.31 Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. 1062 19.32 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 sand) including testing of joints etc. complete : 19.32.1 100 mm dia 19.32.2 150 mm dia 1063 19.33 Providing, laying and jointing half round glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.33.1 100 mm dia 19.33.2 150 mm dia 19.33.3 200 mm dia 19.33.4 230 mm dia 19.33.5 250 mm dia 19.33.6 300 mm dia 1064 19.34 Providing and laying half round RCC pipes class (light duty) with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : Excavation to be paid seperataly 19.34.1 100 mm dia. Half round R.C.C. pipe 19.34.2 150 mm dia. Half round R.C.C. pipe 19.34.3 250 mm dia. Half round R.C.C. pipe 19.34.4 300 mm dia. Half round R.C.C. pipe 1065 19.35.1 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.1.1 & 19.9.1.2 19.35.2 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.2.1 & 19.9.2.2 19.35.3 Deduct for not provide C.I. manhole cover with frame for item No. 19.9.3.1 & 19.9.3.2 1066 19.36 Providing & Fixing of Precast RCC drain cover of size 600x 450 x70mm (thickness) with 4 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1067 19.37 Providing & Fixing of Precast RCC drain cover of size 750x600 x70mm (thickness) with 6 holes, manufactured by using M-30 grade of concrete reinforced with 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1068 19.38 Providing & Fixing of Precast RCC drain cover of size 900x450 x90mm (thickness) with 8 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @ top face will have broom finish etc complete. 1069 19.39 Providing & Fixing of Precast RCC drain cover of size 1150x400 x100mm (thickness) with 10 holes, manufactured by using M-30 grade of concrete reinforced with two layers of 8mm dia Tor Steel @100mm c/c both ways, manufactured by vibro compaction process using joint less FRP moulds, so at to achieve shuttering finish on five faces @top face will have broom finish etc complete. 1070 19.40 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 900X450mm rectangular having weight of (complete unit) (weight of frame 11.7 kg + weight of cover 43.76kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1071 19.41 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 450X600mm rectangular having weight of (complete unit) (weight of frame 1.84kg + weight of cover 14.2kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1072 19.42 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 300X300mm (square) having weight of (complete unit) (weight of frame 1.12kg + weight of cover 4.1kg ± 10%) (LD/2.5MT) having load bearing capacity (Point load 2.5MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement. 1073 19.43 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 600mm (round) having weight of (complete unit) (weight of frame 13.6kg + weight of cover 43.1kg + - 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5 mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1074 19.44 Supplying and fixing of FRP/GRP composite manhole cover with frame of clear opening size 500mm (round) having weight of (complete unit) (weight of frame 11.2kg + weight of cover 41.78kg ± 10%) (HD/25MT) having load bearing capacity (Point load 25MT) as per testing code BSEN 124:1994. Having lifting arrangement should have an insertion of 5mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement 1075 19.45 Deduct for not providing and installing FRP/GRP manhole cover size 19.45.1 900mmx450mm (weight of cover 43.76kg ± 10%) 19.45.2 450mmx600mm (weight of cover 14.2kg ± 10%) 19.45.3 300mmx300mm (weight of cover 4.1kg ± 10%) 19.45.4 600mm (weight of cover 41.78kg ± 10%) 19.45.5 500mm (weight of cover 43.1kg ± 10%) 1076 19.46 Providind, laying and jointing HDPE Double Wall corrugated (DWC) pipes (excavation to be paid seperately) 19.46.1 100 mm dia to 110 mm dia 19.46.2 150 mm dia to 160 mm dia 19.46.3 200 mm dia 19.46.4 250 mm dia 19.46.5 300 mm dia 1077 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. 1078 21.2 Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. 21.2.2 Pre-laminated particle board with decorative lamination on both sides. 1079 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1080 21.4 Add extra for providing and fixing froasted glass instead of float glass 21.4.1 With glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) 21.4.2 With glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) 21.4.3 With glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). 1081 21.5 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge : 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness 21.5.2 With brass cover plate - minimum 1.25 mm thickness. 1082 21.6 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). 1083 21.7 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. 1084 21.8 Providing and fixing machine moulded aluminium covering of approved pattern and design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick and 15 mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-Charge : 21.8.1 Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 21.8.2 Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) 1085 21.9 Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width 1086 21.10 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. For fixed portion & for shutters of doors, windows and ventilators 1087 21.11 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-Charge complete. 1088 21.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and length as required with SS screws etc complete as per direction of Engineer-in-Charge. 21.12.1 Anodized (AC 15 ) aluminium tubular handle bar 21.12.2 Powder coated minimum thickness 50 micron aluminium tubular handle bar. 21.12.3 Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar. 1089 21.13 Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1090 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). 1091 21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. 21.15.1 Anodized (AC15) aluminium 21.15.2 Powder coated minimum thickness 50 micron aluminium. 21.15.3 Polyester powder coated minimum thickness 50 micron aluminium. 1092 21.16 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-Charge 21.16.1 Anodized (AC15 ) aluminium 21.16.2 Powder coated minimum thickness 50 micron aluminium 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. 1093 21.17 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge. (Only weight of grill to be measured for payment). 1094 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately). 1095 21.19 Providing and fixing 50 micron thick reflective one way type heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1096 21.20 Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in-charge of approved brand and make. 1097 21.21 Providing and fixing 25 micron thick Non reflective heat /light control film to window/door glazing with complete accessories as per direction of Engineer-in- charge of approved brand and make. 1098 21.22 Providing and fixing 12 mm thick toughened glass including all connectors and fixing accessories all complete for partitions, cubicals etc. As per direction of Engineer-in-Charge. 1099 21.24 Extra for froasted glass (with eching film) in item No. 21.22 1100 22.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge consisting of: (i)     Ist layer of 22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the levelling course ( levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii)         2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportions. (iii)        Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (with 5 years service guarantee) Using rough Kota stone. 1101 22.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge (with 5 years service guarantee) Using rough Kota stone. 1102 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : a)   Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. b)   IInd course of 20mm cement plaster 1:3 (1 cement: 3 sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. c)    IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. d)      IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) (with 5 years service guarantee) 1103 22.4 Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete (with 5 years service guarantee) 22.4.1 Serrated with central bulb (225mm wide, 8- 11mm thick). 22.4.2 Dumb bell with central bulb (180mm wide, 8mm thick). 22.4.3 Kickers (320mm wide, 5mm thick). 1104 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a)  First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)  Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 1105 22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a)     After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b)    Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c)   Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 1106 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a)  Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b)  Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge: (with 5 years service guarantee) With average thickness of 120mm and minimum thickness at khurra as 65 mm. 1107 22.8 Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic decimeter per square metre including preparation of surface but excluding grading complete with : (with five years service gurantee). Bitumen felt (hessian base) type 3 grade I conforming to IS: 1322. 1108 22.9 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee). 1109 22.10 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6cu.dm per sqm including preparation of surface, excluding grading, complete. (With five years service gurantee). 1110 22.11 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blow or/ and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete. (With five years service gurantee) 1111 22.12 Deduct for omitting in water proofing treatment final course of spreading stone grit 6mm down size or pea sized gravel at 6 cudm per sqm. 1112 22.13 Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. 1113 22.14 Grading roof for receiving water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) 22.14.3 Cement mortar 1:4 (1cement : 4 sand) 1114 22.15 Providing and laying insitu six course water proofing treatment with APP (Atactic poly- propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm,conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. (with 5 years service guarantee) 1115 22.16 Providing and laying in situ four course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with 5 years service guarantee). 1116 22.17 Providing and laying in situ six course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. (with five years service gurantee). 1117 22.18 Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2mm thick water proofing membrane for corrugated roof sheets, black finished reinforced with glass fibre matt consisting in longitudinal and transverse direction at 23°C as 350/300 N/ 5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. (With five years service gurantee). 1118 22.19 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer of the membrane shall be as under:Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : (with 5 years service guarantee) 1119 22.20 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane: (with 5 years service guarantee). 1120 22.21 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. [for item No. 22.18 to 22.20] 1121 22.22 Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of (i)   Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii)     Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) 1122 22.23 Providing water proofing treatment over Roof, Wall, Chhajjas, Balcony with Rubberized elastomeric cold applied liquid waterproofing membrane blend of special resin and rubber with more than 1300% elongation (confirming ASTM-D2370-98), at leakage/seepage area consisting of the following operation. (i)Removal of damaged waterproofing treatment if any like bituminous membrane / plaster/ brick bat koba/screeding etc. (ii) Surface preparation: Roughening of surface by scrubbing with steel wire/ Nylon brush/ Removing all dust particles and washing with adequate water to clean completely, opening of cracks in V groove in size of 5mm x 10m (WxD), filling of cracks with elastomeric creak filler/PU sealent repair of potholes and holor making on roof surface by polymer mortar with adding SBR bonding agent. (iii) Providing and applying 1st coating of rubberized elastomeric liquid membrane as primer (ratio 1:2 1 part liquid membrane and 2 part water) by brush/ Roller/ Spray having minimum thickness of 70-80 micron. Allow the coating to set in natural air for minimum 2 hrs, then put reinforcement by laying 45gsm fibre glass mesh and applying 2nd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 20% water) with minimum thickness 100-120 micron. Allow the coating to set in natural air for minimum 12 hrs. (iv) Providing and applying 3rd coat of rubberized elastomeric liquid membrane (Ratio: 1 part membrane and 10% water). Total DFT (Dry film thickness) thickness after 3rd coat must be 280-300 micron and consumption in three coats @ 6.5kg for 10sqm. (v) Providing and applying 4th and 5th coat of High quality waterproof membrane in white colour, single component special synthetic resin based flexible thixotropic white color coating with excellent UV resistance (SRI - 144) with more than 300% elongation (confirming ASTM D 412-98) in ratio: 1 part membrane and 10% water thickness of 200 micron DFT in two coats, with average consumption @ 5kg per 10 sqm. After application of fourth coat let it air dry for minimum 3 hrs before application of fifth coat. (vi) The treated area must be tested for water leakage/seepage by flooding with water for 48 hrs (vii) Application of membrane coating shall be got done by authorized applicator of manufacturer. (viii) 5 years of service guarantee to be provided.All above operations to be done in order as per direction on Engineer-in-Charge. 1123 22.24 Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure as per DIN 1048 standards, with elongation of 350% as per ASTM D412 & crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge. 1124 22.25 Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, having 80% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and as per direction of Engineer-in-Charge. 1125 22.26 Providing and applying UV Stable polyurethane liquid water proofing membrane having Sun Reflectivity Index (SRI) of 106 on top of concrete roof / Retainning wall / Old layer of bituminous surfaces / Polyurethane foam and metal surfaces in three or more coats @20kg/ 10 sqm consisting of a coat of two component epoxy primer in ratio of 1:3(one part of resin and 3 parts of hardner) at a consumption of 2kg/10sqm. the vital physical and chemical parameters shall be as under : Min Elongation at break of 600% as per ASTM D412 and tensile strength of 3.0 N/mm2 as per ASTM D412. The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and direction of Engineer-in-Charge. 1126 22.27 Supplying & installing waterproofing treatment by using 1.2 mm thick HDPE membrane before casting of the base RCC slab. The pre-applied membrane gets bonded to the underneath of the poured concrete used as base slab. The membrane shall consist of a thick HDPE film, a highly aggressive pressure sensitive adhesive and weather resisting coating which bonds integrally to poured concrete of base slab. The membrane shall conforms to basement waterproofing protection to grades 2, 3 & 4 as defined in BS 8102:2009. The waterproofing membrane shall have following minimum properties: a)    Resist hydrostatic pressure of up to 70 m head of water as per ASTM D5385; b)      Puncture Resistance of 950 N (as per ASTM E154) c)      Elongation of >400 % (as per ASTM D412) d)    Peel Strength of concrete: >1500 N/m (as per ASTM D903) e)      Tensile strength of 28.2 MPA (as per ASTM D412). 1127 22.28 Providing and applying 2.0 mm thick twin colour flexible PVC waterproofing membrane. Flexibility under low temperatures as per EN 495-5 should be < - 20degC. On all horizontal surfaces Geotextile 300 Gsm to be laid over PCC, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane provide 300 Gsm Geotextile Then protection screed of suitable thickness. On all vertical surfaces Geotextile 300 Gsm to be laid along with Vertical wall, than laying PVC membrane over Geotextile and to be sealed with hot air welding method at all joints and over PVC membrane providing protection layer of Drain Board HDPE Dimple sheet before back filling of soil. 1128 22.29 Providing and applying waterproofing & Heat reflecting roof coating with 100% acrylic elastomeric polymers. Contains 30% Volume solid, tensile strength 8 kg/cm², crack bridging, VOC 30 ± 5 gm/ltr upto 2 mm. then applying two coats with forced coverage of 20 sqft/ltr/two coats. The operation shall be carried out after scrapping & propely clening the surface to remove loose particles with wire brush/Jet washer. Apply 1 coat @1 ltr/10 sqm & 3 undiluted coats @ 8 ltr/10 sqm with 4 hrs interval of each coat.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. 1129 22.30 Providing & applying crack fill paste for crack filling up to 5 mm cracks.Widen the crack by putty knife in V/U shape & apply 1st priming coat of crack fill paste diluted with water in 1:1 proportion over the crack by brush. Apply 2nd coat with filling of crack fill paste when the surface is tacky but not dried completely with putty knife & spatula.After 4 hours of application 2nd coat apply 3rd coat of Crack fill paste. The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer-in-Charge 1130 22.31 Providing & applying single pack component, solvent-free, cold applied, Polyurethane modified, elastomeric liquid applied waterproofing membrane- PU coat with excellent UV resistant capacity, The material shall meet the requirement as specified in ASTM D2370-98 of elongation at break of film>350% with geotextile fleece =50% approx.The work shall be carried out as recommended by the manufacturer’s specification & the direction of the Engineer- in-Charge. The product performance shall carry guaranteed for 5 year against any leakage. 22.31.1 For Horizontal surface (with Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 22.31.2 For Horizontal surface (without Geotextile fleece) two coats without dilution & 1 Self priming coat- 50% dilution with water @ 10 kg/m2 1131 22.32 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and Compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1132 22.33 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on positive side. The crystalline slurry shall be capable of self- healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 22.33.1 For vertical surface two coats @ 0.70 kg per sqm 22.33.2 For horizontal surface one coat @1.10 kg per sqm. 1133 22.34 Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. crystalline dryshake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product Performance shall carry guarantee for 10 years against any leakage. 1134 22.35 Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge.The product performance shall carry guarantee for 10 years against any leakage. 22.35.1 For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 22.35.2 For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @ 0.070 kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar @ 0.040 kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040 kg to fill the hole) 1135 22.36 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 1136 22.37 Providing and applying waterproofing treatment in bathroom or tiled balcony area without breaking or removing tiles, by using waterproofing sheets as per manufacturers data sheet instructions. Permitting use of bathroom/balcony after 24 hours of application of treatement, Complete with materials and labour and gurantee of leakage for a period of 5 year. 1137 23.11 Providing and fixing 2 mm thick homogeneous conductive PVC (Poly Vinyl Flooring) EN (European Standard), total weight is 3250 g/m2, approx. PUR (Polyurethane Reinforced ), abrasion group P: ≤2.00 mm, residual indentation approx. 0.03 mm, anti-bacterial and fungal resistance, castor wheel test qualified, dimensional Phthalate free, directional in design.The floor finish should be termite free at the room perimeter passing over a concealed cove forming and continuing up on the wall upto 100mm.Recommended to use in area like ICU , Post operative, Recovery rooms, OPD, Patient rooms, Corridors ,passages etc. 1138 23.12 Providing and fixing permanently static dissipative pressed homogeneous conductive PVC ( Poly Vinyl Flooring) EN (European Standard), anti static, wear layer thickness is 2mm (EN429), vinyl flooring having carbon backing with total weight 3000 g/m2 ESD approved, restorable properties, available in rolls. 100% recyclable (eco - freindly). Low VOC emission after 28days of installation (lower than ≤100μg/m3), Phthalate free non-directional in Design. Recommended to use in area like Operation theater, ICU, Server room, etc. 1139 23.13 Providing and fixing 0.92mm thick hetrogeneous compact PVC (Poly Vinyl Wall Covering) for Interior wall area, with wear layer thickness 0.12mm of PVC, EN(European Standard) total weight is 1500 g/m2, approx PUR (Polyurethane Reinforced), good resistance to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28 days of installation (lower than ≤10μg/m3), phthalate free, directional in design, The wall finish should termite free at the room perimeter. Recommended to use in area like OT,ICU, Corridors, Patient Room etc. 1140 23.14 Providing and fixing 1.3mm thick homogeneous PVC (Poly Vinyl Wall Covering) for interior area with wear layer thickness 1.3 mm of PVC, EN (European Standard) total weight is 2100 g/m2,approx. PUR (Polyurethane Reinforced), good resistant to chemical and fire, doesn’t favour in growth of fungi and bacterial, 100% recyclable (eco-freindly), low VOC emissions after 28days of installation (lower than ≤10μg/m3), phthalate free, directional in design.The wall finish should termite free at the room. Recommended to use in area like OT.ICU,Corridors, Passages , Patient Room Etc 1141 23.15 Supply and installation of 2mm thick homogeneous vinyl flooring, Highest abrasion wear rating Group T (EN660), binder content exceeds 55% of the flooring composition, no waste technology, consisting of PVC resin, plasticizers and stabilizers, type I. flooring ( (EN ISO 23997) max 0.4%, Abrasion group (MSZ EN 660-1) T, Fire resistance EN 13501-1 BF1-s1, Slip resistance DIN 51130 R9, EN 13893 DS, electrical resistance EN 1815 <2 kv, Chemical resistance EN ISO 26987, Castor chair resistance EN ISO 4918, Hygenie Bacterial resistant, Seaming method - hot welding, finishing complete . Recommended to use in area like Operation theater, ICU, Server room, etc. 1142 24.8 Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with self- drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. 1143 24.9 Providing and fixing thermal insulation with Resin Bonded glass wool conforming to IS: 8183, having density 48 kg/m3. 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawl plug and washers and held and in position by crisscrossing GI wire etc. complete as per directions of Engineer-in-Charge. 24.9.1 Providing and fixing insulation with resin bonded Glass wool 24.9.2 Providing and fixing insulation with resin bonded Rock wool 1144 24.11 Providing and fixing precoatedgalvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsmlength upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1145 24.12 Providing and fixing precoatedgalvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete : 24.12.1 Ridges plain (500 - 600mm). 24.12.2 Flashings/ Aprons.( Upto 600 mm) 24.12.3 North light curves. 24.12.4 Barge board (Upto 300 mm). 24.12.5 Crimp curve 24.12.6 Gutter. (600 mm over all girth). 1146 25.1 Providing and fixing white vitreous china Anti germ Fluoro-Polymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440x575x250 mm With integral foot rests. (Premium Range) 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410x515x255 mm with integral foot rests. (Premium Range) 1147 25.2 Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360x545x395 mm with solid poly propelyne made soft closing seat cover (Premium Range) 1148 25.3 Providing and fixing white vitreous china European Wall hung Anti germ Fluoro-Polymer Coated water closet of approved shape with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propylene) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380x520x375 mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390x570x365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500x360 mm with solid poly propelyne made, soft closing seat cover (Premium Range) 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360x500x330 mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) 1149 25.4 Providing and fixing white vitreous china Anti germ fluoro-polymer coated couple water closet flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete . 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420x710x810 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380x610x805 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375 x 650 x 800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) 1150 25.5 Providing and fixing white vitreous china Anti germ fluoro-polymer coated single piece W.C. dual flushing capacity 3 and 6 litre of approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370x695x795 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 395x710x730 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.3 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 385 x 720 x 710mm with solid poly propelyne made soft closing seat cover.(Premium Range) 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 360 x 640 x 685 mm with solid poly propelyne made soft closing seat cover.(Premium Range) 1151 25.6 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet along with dual flushing cistern flushing capacity 3 & 6 litre approved shape with 15mm quarter turn angular stop cock and pvc connection pipe i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 760X360X635mm with solid poly propelyne made soft closing seat cover (Premium Range) 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 380x650x730 mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) 1152 25.7 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol technology), 15mm quarter turn angular stop cock, 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 1153 25.8 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology), 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required all fittings and fixtures etc. complete. 25.8.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 570x820x195 mm with wall mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x820x195 mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system (decol technology). (Premium Range) 1154 25.9 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin with 15 mm C. P. wall mounted single lever concealed basin mixture, (cartridge size 32 mm) 32 mm C. P. brass waste coupling length 130mm and 32 mm C. P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185 mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) 1155 25.10 Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with 15 mm Table mounted single lever Tall boy basin mixture, (cartridge size 32 mm) 15mm quarter turn angular stop cock, 32 mm C. P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and making good the wall and floors wherever required. 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185 mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140 mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) 1156 25.11 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated urinal (Inbuilt spreaders, bottle trap and ceramic waste coupling) with 15mm brass pressmatic auto closing concealed urinal flush valve with wall flange (decol technology, 400000 operation warranted) i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) 25.11.2 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 475x315x715 mm. (Premium Range) 25.11.3 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 385x325x635 mm. (Premium Range) 1157 25.12 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve for urinal complete set with installation box with control cock. (Premium Range) 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) 1158 25.13 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) with 15mm Brass made pressmatic (Decol technology, 400000 operation warranted) concealed flushing Stop cock complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required . 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480x300x740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) 1159 25.14 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling)with sensor complete including painting of fittings and brackets, cutting and making good the wall and floors wherever required. 25.14.1 White Vetrious China made Flat Back Anti germ Fluoro-Polymer Coated Urinal (Inbuilt spreaders, Inbuilt Bottle trap and inbuilt ceramic Waste coupling) Size 340x325x650 mm with sensor (Premium Range) 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 7475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor for flushing. (Premium Range) 1160 25.15 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with chrome plating. (Premium Range) 1161 25.16 Providing & Fixing 8mm thick froasted Urinal glass partition size height 900 mm top width 450mm and bottom width 300mm brass made bracket with chrome plating. (Premium Range) 1162 25.17 Providing & Fixing plain bath tub of size 180x80x47cm body made of PMMA (Poly Methyl metha acrylate) with 20mm wooden reinforcement. (Premium Range) 1163 25.18 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Pillar cock. (Premium Range) 1164 25.19 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn)Bib cock. (Premium Range) 1165 25.20 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating. 10 micron and chrome plating 0.3 micron, quarter turn) Angular stop cock. (Premium Range) 1166 25.21 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Concealed stop cock. (Premium Range) 1167 25.22 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range) 1168 25.23 Providing and fixing in position best Indian ( bonut size 24mm, ceramic disc size 19mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 3-in1 Wall Mixer .(Premium Range Sanitary Ware) 1169 25.24 Providing and fixing in position best Indian C. P. brass made quarter turn (Ceramic disc Size 25mm) Flush Cock for Indian W. C. (Orissa Pan). (Premium Range) 1170 25.25 Providing and fixing in position best Indian single Lever Auto Mixing Wall Mixer (Cartridge Size 40mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1171 25.26 Providing and fixing in position best Indian single Lever Auto mixing Basin Mixer (Cartridge Size 32mm, nickel plating 0.10 micron and chrome plating 0.3 micron) For Wash Basin area use only. (Premium Range) 1172 25.27 Providing and fixing in position best Indian single Lever Auto Mixing Diverter (Cartridge Size 47mm, nickel plating 0.10 micron and chrome plating 0.3 micron) for Shower area use only. (Premium Range) 1173 25.28 Providing and fixing in position best Indian C. P. brass made Spout (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1174 25.29 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 300mm (nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1175 25.30 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 450mm (nickel plating 0.10 micron and chrome plating 0.3 micron).(Premium Range Sanitary Ware) 1176 25.31 Providing and fixing in position best Indian C. P. brass made Shower Arm Length 600mm (nickel plating 0.10 micron and chrome plating 0.3 micron) .(Premium Range Sanitary Ware) 1177 25.32 Providing and fixing in position best Indian shower rose 300x300mm square body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range Sanitary Ware) 1178 25.33 Providing and fixing in position best Indian shower rose 150mm dia, body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1179 25.34 Providing and fixing in position best Indian shower rose 200mm dia body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles .(Premium Range) 1180 25.35 Providing and fixing in position best Indian shower rose 240mm body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) 1181 25.36 Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2- way Bib Cock .(Premium Range) 1182 25.37 Providing and fixing in position best Indian Health Faucet with 8mm dia 1.20 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).(Premium Range Sanitary Ware) 1183 25.38 Providing and fixing in position best Indian Auto Closing Pillar Cockdody with 65 mm extension (with DECOL cartridge) for wash basin use. (Premium Range) 1184 25.39 Providing and fixing in position best Indian Auto Closing Bib Cock with built in control cock wihh wall flange (with DECOL cartridge) for common area use. (Premium Range) 1185 25.40 Providing and fixing in position best Indian Auto Closing Urinal valve open type with built in control cock wihh wall flange (with DECOL cartridge) for urinal use only. (Premium Range) 1186 25.41 Providing and fixing in position best Indian Auto Closing Urinal valve concealed type (with DECOL cartridge) for urinal use only. (Premium Range) 1187 25.42 Providing and fixing in position best Indian Auto Closing wall mounted Pillar Cock (with DECOL cartridge) for wash basin use only. (Premium Range) 1188 25.43 Providing and fixing in position best Indian Auto Closing 40mm Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1189 25.44 Providing and fixing in position best Indian Auto Closing 40mm Dual Flow (3.0/6.0 liter) Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/ cartridge). (Premium Range) 1190 25.45 Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range) 1191 25.46 Providing and fixing in position best Indian Sensotronic Sensor Faucet for Wash Basin use only. (Premium Range) 1192 25.47 Providing and fixing in position best Indian Sensotronic Sensor battery & electrical oprated type (9V transformer) Faucet For Urinal use only. (Premium Range) 1193 25.48 Providing and fixing in position best Indian Sensotronic Sensor concealed type Faucet For Wall Mounted Water Closet use only. (Premium Range) 1194 25.49 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 300 mm long. (Premium Range) 1195 25.50 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Rail 600 mm long. (Premium Range) 1196 25.51 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Swivel Towel holder Twin Type. (Premium Range) 1197 25.52 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Single Towel Ring Square. (Premium Range) 1198 25.53 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dish Holder. (Premium Range) 1199 25.54 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Soap Dispenser with Metallic Bottle. (Premium Range) 1200 25.55 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Tumbler Holder. (Premium Range) 1201 25.56 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet paper holder with Flap. (Premium Range) 1202 25.57 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Toilet Roll Holder. (Premium Range) 1203 25.58 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Glass Self-size 600mm with toughened glass (Premium Range) 1204 25.59 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Double coat Hook. (Premium Range) 1205 25.60 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) Towel Rake 600 mm. (Premium Range) 1206 25.61 Providing and fixing in position best Indian C. P. Brass made (0.3 micron Chrome and 10 micron Nickel plated) W. C. Brush Holder. (Premium Range) 1207 25.62 Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range) 1208 25.63 Wall Hung Basin: Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) 25.63.4 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 500x440x385 mm. (Premium Range) 25.63.5 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 635x485x305 mm. (Premium Range) 1209 25.64 Wall Hung Basin ; Providing and fixing white vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, 15 mm C. P. brass pillar cock, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 635x430x190 mm. (Premium Range) 1210 25.65 Providing and fixing in position best Indian, quarter turn table mounted sink mixer (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1211 25.66 Providing and fixing in position best Indian, quarter turn wall mounted sink cock (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron). (Premium Range) 1212 25.67 Shower Glass Cubical: Providing and fixing toughen glass shower enclosure conformed Is 2553 (part 1. 1990) or IS 14900. 2000 or IS 2835.1987 or IS 14450. 2000 with C. P. brass 5 Year warranted hardware, 19mm dia SS 304 grade stabilizer, all plastic Parts of food grade plastic and all glass shall be toughened at 700 degree Celsius and Anti lime scale treated including painting of fittings, cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete. (Premium Range) 25.67.1 Providing and fixing corner entry 6 mm toughen glass made to measurement shower enclosure size 1200mm x1200mm x 1950mm with aluminum profile on sides, shower enclosure with door sliding on both sides. (Premium Range) 25.67.2 Providing and fixing 8 mm toughen glass wall to wall sliding shower enclosure with one fixed glass and one silding door with a Towel Rod Fixed on the fixed glass size Hight:2000 mm Width: 1500mm to 2000mm. (Premium Range) 25.67.3 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed withwall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1213 25.68 Providing and fixing 8 mm toughen glass made to measurement door Openable (inside/outside) shower enclosure two parts Wall to Wall enclosure with one fixed glass and openable door fixed with wall with square hardware & profile glass size Hight: 2000mm Width 800mm to 1200mm. (Premium Range) 1214 25.69 providing and fixing white tempered glass showerpenal with special Surface body materials tempered glass with glass special surface PVC back. ABS Movable tops Shower, 4 moveable ABS body massage jets, Hand shower with fiexible hose,Brass Sout, shelf, Thermostatic mixer with diverter, 40 cm stainless steel braided hose, Minimum water pressure required 2 bar. 1215 25.70 Thermostat Mixer : Providing and fixing in position best Indian, concealed high flow bath and shower mixer with thermostatic control cartridge (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1216 25.71 Providing and fixing in position best Indian, exposed wall mounted bath and shower mixer with thermostatic control cartridge with button attachment on spout with connecting legs and wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) .(Premium Range) 1217 25.72 Providing and fixing in position best indian, eko exposed shower mixer (wall mounted) with thermostatic control cartridge, 115mm long bend pipe on lower side, connecting legs and wall flange (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1218 25.73 Providing and fixing in position best Indian, exposed shower mixer (tub mounted) with thermostatic control cartridge, with button attachment on spout with straight legs (standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1219 25.74 Providing and fixing in position best Indian, 4 - way diverter consisting of concealed body and wall flange for multiple shower working with one shut-off position and 3 outlets for body shower, head shower and spout ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function). (Premium Range) 1220 25.75 Providing and fixing in position best Indian, thermostatic concealed high flow control valve with wall flange ( standard temperature range 15 degree c to 60 degree c, cartridge made of high performance thermostatic Polymer material with Anti scaled function) . (Premium Range) 1221 25.76 Medical Faucets : Providing and fixing in position best indian, single lever surgical purpose elbow action basin mounted mixer with extended Operating lever without popup waste system with 450mm long braided hoses (cartage size32mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1222 25.77 Providing and fixing in position best Indian, surgical purpose elbow action pillar cock with extended Operating lever.( bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) (Premium Range) 1223 25.78 Providing and fixing in position best Indian, surgical purpose elbow action wall mounted pillar cock with extended Operating lever and wall flange. (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn). (Premium Range) 1224 25.79 Providing and fixing in position best Indian, 692mm long, satin finish C. P. Brass grab bar made of 304 grade ss i/c all nuts and screw (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1225 25.80 Providing and fixing in position best Indian, satin finish, C. P. Brass grab bar with left/right 90 degree angle, made of 304 grade ss i/c all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1226 25.81 Providing and fixing in position best Indian, C. P. Brass grab bar vertical swing, 304 grade ss made all nuts and screws. (0.3 micron chrome and 10 micron nickel plated). (Premium Range) 1227 25.82 Providing and fixing 8mm thick frosted safety glass Urinal partition size 900mm height and 450mm width, fixed with C P brass bracket of appropriate size i/c cutting and making good the wall and floors wherever required with all fittings and fixtures etc. complete.(Premium Range) 1228 27.4 Providing and fixing Stainless steel plate 304 grade of 1.50mm thick, including writing with Embossing of letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1229 27.5 Providing and fixing of name plate for offices name of Stainless steel plate 304 grade of 1.50mm thick, including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer- in-Charge. 1230 27.6 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with 1.25m Chromium plated Steel Pipe 15mm dia, compete as per direction of Engineer-in-Charge. 1231 27.7 Providing and fixing Aluminum composite panels Silver colour with matte finish, 3mm thick, (0.25mm 2.5mm and 0.25mm) sheet for name plate including writing with computerized vinayle sheet letters of required size including fixing at required placed with studs, screws and rawl plugs etc. compete as per direction of Engineer-in-Charge. 1232 27.8 Providing and fixing stainless steel English (Capital) and Hindi letters in standard pattern bellow type made with 1.20 mm thick stainless steel (ASI Grade- 304 ) Depth of letter shall not be less than 30mm and rate includes welding/soldering of joints polishing, buffing and fixing on the wall, plate and beam surface at any height with necessary nut and bolts/fastener wherever is required complete as per direction of Engineer-in-Charge. 1233 27.10 Providing and fixing of prestressed vertically casted concrete panels (both surfaces should be smooth and having grooves on both faces) of M-40 grade of concrete of size 2100x300x50 mm having minimum 4 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed horizontally in full length of panel with prestressed precast concrete column of M-40 grade of size 3000x150x150 mm having minimum 7 nos of high tensile steel wire as per IS 6006:2014 of dia 3 mm placed vertically in full length to erect precast boundary wall panels to height 2100 mm from GL including excavation of pit of size 750x750x900 mm in all kind of soil except rock for erection of columns and grouting the pit with M-20 grade of concrete. Manufacturing, transportation and installation at site all complete as per the direction of Engineer-in-Charge. 1234 27.11 Extra for every additional height of 0.3 m up to height of wall 3 m 1235 28.35 Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm. 1236 28.36 Providing and fixing of stone planter (bench) made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1200mm, width 500mm, legs height 500 mm. 1237 28.37 Providing and fixing of stone table made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 no sealer coat to prevent from weather including fixing on a pedestal (cost of pedestal to be paid separately)etc. complete as per direction of engineer in charge. Size: length 1000mm, width 600mm, legs height 750 mm. 1238 28.38 Providing and laying C.C. pavement of mix M- 25 with ready mixed concrete from batching plant including centering and shuttering complete. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, with wire brush etc. complete as per specifications and directions of Engineer- in-Charge.Note: Cement content considered in this item is @ 330 kg/cum. 1239 29.1 Preparation of site plan and location plan with total station surveying showing all individual structures and features like trees, roads, culverts, nallas, electric poles, telephone poles, sewer lines, chambers, water supply lines, hand pumps, well etc. complete along with showing location of roads proposed in master plan. i/c Contours of entire area at 0.5 m. intervals using auto level, preparing of site plan in soft copy (using autocad) in suitable scale as desired by engineer-in-charge duly indicating north direction. Rate includes providing 1 digital copy and six hard copies, one print on tracing film, khasra map duly showing the land and location plan (index plan) and google image of the land. Rates are inclusive of transportation charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) 29. 1.1 Upto 1 Hectare 29.1.2 1 Hectare to 2 Hectare 29.1.3 Add extra for each additional one Hectare or part there off 29.1.4 Excavation of trial pit of size 1.20 m X 1.20 m with minimum depth of 0.9 m and maximum depth of 3.5m as directed by the Engineer in Charge. Trial pit shall be taken at suitable location/ locations as directed by Engineer in charge and shall be indicated on the site plan showing details of soil strata. 1240 29.2 Preparation of double line plan after measurement of internal as well as external dimensions of existing buildings/structures and plotting the same in suitable scale as directed by Engineer-in-charge. 1241 29.3 Preparing of double line plan for planning of addition and alteration work after measurement of internal as well as external dimensions and details of existing door window, ventilator openings and partitions, addition /alteration done previously in buildings/structures and plotting the same separately showing sectional elevations (minimum two numbers) and all elevations along with all relevant details like doors, windows stairs etc in suitable scale as directed by Engineer-in-charge. The consultant shall also submit detailed condition survey report. 1242 29.4 Performing Plate Load Test (P.L.T.) for Determining soil bearing capacity (SBC) at site including submission of Geotechnical Report and recommending bearing capacity in accordance with IS-1888-1982 (Without Conveyance). 1243 29.5 Performing Standard Penetration Test for determining soil bearing capacity (SBC) in accordance with IS-2131-1981 and submission of Geotechnical Report on bearing capacity based on SPT in accordance with IS-6403-1981 (Without Conveyance) 1244 29.6 Transportation charges for transportation of Geotechnical testing equipments for plate load test or standard penetration test upto a distance of 100km. (upto 100km going and 100km returning from district H.Q. both way) Rates are inclusive of Loading and unloading of testing equipments and other incidental charges during both journeys to be paid only once for one set (separate for PLT or SPT) of testing. 29.6.1 Up to 100km (both way) 29.6.2 Add extra for distance beyond 100km and upto 150km. (both way) 29.6.3 Add extra for every additional km beyond 150km (both way) 1245 29.7 Preparation of detailed estimate on the basis of the working drawing supplied by the department and current SOR applicable, including computation of bill of quantities (BOQ) of material and supplying the same in six hard copies and one soft copy to the Engineer-in-Charge and if required revision of the same without any additional charges. (Work shall be got done through consultants duly empanelled with chief Architect MP P.W.D.) The estimate shall be prepared only in standard format prescribed as per appendix 14 of this SOR. 1246 29.8 Preparation of DPR including site visit to verify contours & soil reports and preparation of master plan of campus including architectural working drawings and estimates in prescribed format as per appendix 14 of this SOR to obtain AA; and there after architectural drawings for statutory approvals and detail drawings at construction stage; and as constructed drawings on completion of work the DPR. Bifurcation of professional fee payable in stages as per this item shall be in accordance with List-1, List-2 & List-3. Given in preambles of this chapter 3.All work such as preparation of DPR, working drawings, statuary drawings, details drawings and as constructed drawings shall be done by the same architect/consultant to ensure consistency in services, even if time required to complete all stages as per Activity sheet exceeds the contract period. 1247 29.9 Preparation of the structure design & drawings by a structural engineer empanelled with the Chief Architect MP PWD on the basis of architectural drawings supplied/approved by the department, in accordance with relevant codes/manuals and according to the Terms & Conditions, prescribed in Activity Sheet No-1, List-4 given in Annexure-14 appended with SOR. Design and drawing shall also include ‘Tables’ for the bar-bending schedules (BBS) and concrete/steel consumption. The design and drawing shall be submitted to the Engineer-in-Charge in six hard copies and one soft copy for execution. The payment shall be done in accordance with relevant stage in activity sheet and list. 29.9.1 First time design work 29.9.1.1 Built up area upto 500 sqm 29.9.1.2 Built up area more than 500 sqm and upto 3000 sqm 29.9.1.3 Built up area more than 3000 sqm. 29.9.2 Repetition of structural design of a structural design done by the structural himself or by any other structural engineer at different site, where S.B.C. or seismic zone is different.(only plinth area payment to be paid) 29.9.2.1 Plinth area upto 500 sqm 29.9.2.2 Plinth area more than 500 sqm and upto 3000 sqm 29.9.2.3 Plinth area more than 3000 sqm 1248 29.10 Assessment of load carrying capacity and structural soundness of existing building mainly comprising of R.C.C. structure using existing information such a existing drawing, design and footing details, if available. The consultant shall carry out destructive/non destructive testing of structure at site including site investigation which may require opening of footings by digging adjoining ground fill and restore backfill structure after testing is done. This work shall be performed by a structural engineer (proof checking) empanelled with the chief Architect MP PWD Bhopal or any government engineering college. The rate shall include all charges for labour, testing, consultation of geotechnical consultant and site visit to carry out site testing Per Sqm (built up area of wing/block of existing building where construction is proposed). 1249 29.11 Drafting structural drawing on the basis of the structural design supplied by the department in accordance with all relevant codes/manuals and as per IS: 1893- 2002 and IS: 13920-1993 with updation. The work shall include making revision/compliance if any and obtaining approval of drafting work, without any additional cost within time specified by the Engineer-in-Charge or from the competent authority. The drawings for approval shall be submitted to the Engineer- in- Charge in two hard copies (minimum size A-2) and there after fair drawings on 100 micron film along with seven copies of amonia prints (minimum size A-1) and one soft copy. Drawings shall be stamped and signed with the statement that Drafted by me as per structural design done or got done by the department. Note:- This work can be done only through a person having qualification of Diploma in civil engineering/BE (civil engineering) and having certificate in AutoCAD issued by AutoDesk or by its authorized institution.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
22.
Educational and Research Institute #9617219 AOC
Tender For Supplying, Installation, Testing And Commissioning Of Machines & Equipment For Civil Engineering Department At Ttaadc Polytechnic Institute, Khumulwng, West Tripura For The Project Improvement Of Infrastructure In Ttaadc Polytechnic Institute, Khumulwng, West Tripura District Under Higher Education Department Under The Nec Scheme. , Supplying, Installation, Testing And Commissioning Of Machines & Equipment In Civil Engineering Department At Ttaadc Polytechnic Institute, Khumulwng, West Tripura Under The Nec Scheme Improvement Of Infrastructure In Ttaadc Polytechnic Institute, Khumulwng, West Tripura, District Under Higher Education Departmen. , Computerized Universal Testing Machine, 6 Pillar Type, For Conducting Tests On Various Types Of Ferrous And Non-Ferrous Materials; Consisting Of- Loading Unit 600 Kn Capacity, Hydraulic Jaws And Pumping System, Clamping Jaws For Round Specimens, Clamping Jaws For Flat Specimens, Pair Of Compression Plates, For Compression Test, Rollers Of 160 Mm Width And 30 Mm Diameters, For Transverse Test, Bending Table Stopper, Allen Keys, Spanners, Double Shear Test Attachment, Bend Rebend Test Attachment, Electronic Extensometer. , Steel Bar Cutting Machine , Vernier Caliper , Stainless Steel Ruler, 1M Length , Mixer Machineries Concrete Mixer The Counter Balanced Mixing Drum Is Easy To Tilt Two Cubic Feet Mix Capacity. Total Drum Volume Is 3 Cubic Feet.. Suitable For Operation On 220 Volt Single Phase, 50 Cycle, A.C. Supply , Isi Cube Mould Cube Mould, With Base Plate : As Per Is : 516 With Isi Mark Cube Mould, 15 Cm X 15 Cm With Base Plate (Made Of Cast Iron - Isi Mark) , Cement Mortar Cube Mould Cement Mortar Cube Mould Cube Mould, 7.06Cm X 7.06Cm With Base Plate (Made Of Mild Steel) , Vibrating Machine Vibration Machine With Timer : Is : 4031 This Apparatus Is Suitable For Making Cubes Of 70.7 Mm. For Mortar Strength Evaluation. The Mould Is Mounted On A Vibrating Platform With A Frequency Of 12,000±400 Vibrations Per Minute. To The Platform Are Attached Four Matched Springs. The Whole Assembly Is Operated By A Revolving Shaft With An Eccentric Mechanism. The Machine Is Supplied With A Timer, A Switch Mounted On A Steel Panel And A 70.7 Mm. Steel Cube Mould With A Base Plate. , Electronic Balance Capacity 500Gm, 0.01 Gm Accuracy , Electronic Balance Capacity 5Kg, 0.1 Gm Accuracy , Electronic Balance Capacity 20Kg, 0.5 Gm Accuracy , Electronic Balance Capacity 100 Kg, 10G Accuracy , Air Permeability Apparatus (Blaine Type) Isi Certification Mark Is;5516, Fitted In Aluminium Box , Vibrating Table Vibrating Table For Compaction Concrete Cube, Cylinders The Table Deck Size 50 Cm X 50 Cm And Has Stops Along Its Edges To Prevent Moulds From Walking Off The Table During Vibration The Variably Pitch Pulley Arrangement Permits The Frequency To Be Varied Sleeplessly Between A Maximum Of 3600 Vibrations Per Minute A Speed Regulation Handle Is Provided For Increasing Or Decreasing The Frequency. The Vibrating Deck. A Switch Is Provided For Starting The Motor. Operation On 440 Volts, Three Phases, A.C. Supply. Table Top - 50 Cm X 50 Cm , Curing Tank Water Curing Bath With Agitation System Digital Indicator For Temperature * 24- Hour Cycle From Time Of Mixing * Controlled 100° C +/- 2° C. Temp. For Concrete * Controlled 27° C + 2° C Curing Temperature For Grey Cement The Tank Has Been Designed To Accommodate 150 Mm / 70.6 Mm Casted Cubes Up To 12/24 Cubes And Fully Insulated. Complete With A Hinged Lid, Heated, Thermostat And Recirculation Pump. Provision Of Two Removable Racks Allowing Free Circulation Of Water Around Each Cube. The Pump, Drain Valves And Electrical Equipment Are Housed In A Compartment Located At One End Of The Tanks. The Tank Is Heated By An Immersion Heater Under Normal Conditions And Refrigeration System For Grey Cement, The Temperature Is Controlled At 35Deg.C. +/- 2 Deg.C, For About 15 Minutes After Immersion Of The Freshly-Made Specimens. Curing Tank For 12 Moulds Of 150Mm/24 Moulds Of 7.06Mm , Vicat Apparatus Box With Isi Certification Mark, Is:5513, Fitted In Aluminium , Le-Chatelier Mould With Isi Certification Markis:5514, Each , Le-Chatelier Water Bath Controller Size 12X9x12. , Crushing Test Apparatus Based On Is: 9376-1979, Mould And Accessories Which Consists Of A Steel Cylinder Of 150Mm Dia. A Plunger And A Steel Base Plate. , Slump Cone With Tamping Rod Slump Test Apparatus Is : 1199 Is ; 7320 Consists Of Slump Cone Fitted With Handles And Foot Pieces In Position. Base Plate In Octagonal Shape Two Clamps Slide Over The Foot Grips Of A Standard Slump Cone And Hold It Securely While Filling And Roding. A Combination Swivel Carrying Handle. Complete With Graduated Temping Rod 0-60 Cms Long And 16Mm Dia With 0-30 Cms Scale Graduation , Measuring Cylinder(Plastic)(1 Liter) , Measuring Cylinder(Plastic) (500 Ml) , Measuring Cylinder(Plastic) (100 Ml) , Measuring Cylinder (Glass) (1 Liter) , Measuring Cylinder (Glass) (250 Ml) , Le-Chatelier Flask Or Specific Gravity Bottol (Glass) 250 Ml , Glass Funnel , Compaction Factor Apparatus Compaction Factor Apparatus: Is : 5515: Is:1199 Consists Of Two Conical Hoppers And A Cylinder Mounted On A Rigid Metal Frame The Lower Openings Of The Hoppers Are Fitted With Hinged Trap-Doors For Release And During The Fall Of Material. Complete With Trowel Tamping Bar 0-60Cms Long X 16Mm Dia , Sample Tray (Enamel Tray), Size 650X500x50mm , Sample Tray (Enamel Tray), Size 850X600x50mm , Pycnometer/Specific Gravity Bottle (1 Litre) , Cylindrical Mould 150 Mm Dia X 300 Mm High, Cast Iron. , Beam Mould 150 Mm X 150 Mm X 700 Mm Made Of Cast Iron , Beam Mould 100 Mm X 100 Mm X 500 Mm Made Of Cast Iron. , Sample Tray (Enamel Tray), Size 350X300x80mm , Sample Tray (Enamel Tray), Size 250X200x50mm , Sample Tray (Enamel Tray), Size 450X400x50mm , Trowel, Ref Standard Is: 4031, 100 To 150Mm Long Blade With Straight Edge. Weight 210 + 10G , Trowel, Ref Standard Is:5515, 200Mm Long Blade, Weight 210 + 10 G , Spatula, 200Mm Blade With Wooden Handle , Density Basket , Hand Brush , Plastic Water Measuring Cylinder (1 Liter) , Plastic Jar For Measuring Water (500 Ml) , Plastic Jar For Measuring Water (100 Ml) , Asbestos Gloves , Hammer With Wooden Handle , Vernier Caliper , Circular Pan/Tray For Morter Mixing , Digital Compression Testing Machine, As Per Is : 14858-2000, 2000Kn Capacity, Electrically Operated With Three Load Gauges 2000Kn, 1000Kn, 500Kn With Nabl Calibration Certificate With Traceability Certificate. , Standard Penetration Test (Spt) Set Consisting Of Split Spoon Sampler, Drive Weight, Guide Pipe Assembly, Tripod, With Rope 19Mm Dia X 10 Mt Length A Drill Rod, 1M Long Complete With Adaptor, 10 Nos Hand Operated Extractor 38Mm Mm Dia. Specimen , Portable Digital Dissolved Oxygen Meter Display : Lcd Size : 29 Mm X 28 Mm Dual Function Lcd Accuracy : Dissolved Oxygen:+0.1Mg/L, Oxygen In Air:+ 0.1% O ², Temperature:+ 0.8 °C/1.5 °F Resolution : Dissolved Oxygen:0.1Mg/L, Oxygen In Air:0.1% O ² Temperature:0.1 °C. Data Hold: Freeze The Display Reading. Operating Conditions: Temp: 0 To 50 Deg C, Humi: Less Than 80% Rh. Operating Range: Temperature: 0 °C To 50 °C (32 °F To 122 °F) Humidity: Max. 80% Rh. Power Off : Auto Shut Off Saves Battery Life, Or Manual Off By Push Button Power Supply : Dc 1.5V Battery ( Um-4/Aaa ) X 4 Pcs Protection Class: Ip-65: 0 To 50, Ip-67: 0 To 30. Dimensions: 180 X 40 X 40 Mm (7.1 X 1.6 X 1.6 Inch). Weight : 176 G/0.39 Lb Memory Recall: Records Maximum, Minimum And Average Readings With Recall. Measurement & Range : Dissolved Oxygen:0 To 20.0 Mg/L, Oxygen In Air:0 To 100.0 %, Temperature:0.1 , Digital Chlorine Meter •The Meter Measures The Free And Total Chlorine (Cl) In The 0.00 To 3.50 Ppm (Mg/L). The Measuring Method Is An Adaption Of The Usepa Method 330.5 For Waste Water And Standard Method 4500-Ci G For Drinking Water. Range: Free Chlorine (Cl): 0.00 To 3.50 Ppm (Mg/L), Total Chlorine (Cl): 0.00 To 3.50 Ppm (Mg/L). Resolution: 0.001(Mg/L). Light Source: Led, 525 Nm. , Digital Tds Meter Using Latest Microcontroller, Auto Ranging (5 Ranges From 200Ppm To 1000Ppt), Temperature Compensation, Auto Cell Constant Measurement, Touch Keys Along With Tds Cell. (Table Model) , Vertical Double Water Distillation Apparatus Temperature 400 Degree Celcius, Color : Transparent, Frequency: 50 Hz, Display: Manual, Weight 10 Kg, Voltage 220Volt, Capacity 5000 Ml With Two Glass Flask With Embedded Heater In Spiral Type Glass Coil Internally At The Bottom, Double Wall Condenser, Level Cup, Delivery Tube, Metal Stand , Clamp, Boss Head, With Automatic Cutoff Device Etc. As Required , Biological Oxygen Demand (Bod Incubator) Temperature Range From 5 °C To 50 °C. Inner Chamber Made Of Stainless Steel, Temperature Controlled And Indicated By Automatic Solid State Electronic Digital Temperature, Controller Cum Indicator. Outer Body Made Of Thick Gauge M.S. Sheet And Inner Chamber Made Of Stainless Steel. Both The Wall Gapis Highly Insulated With Glass Wool. Door Is Also Double Walled And Insulated With Glass Wool Hanged With Heavy Hinges And Fitted With Rubber Magnetic Gasket. An Inner Glass Door Is Provided For Viewing The Samples On While On Test. A Finned Type Low Wattage Heater Is Provided For Raising Temperature Up To 50°C. A Sealed Type Thermostatically Sealed Compressor Filled With Free On Gas And Fitted With All Accessories Viz. Condenser Capacitor Etc. Are Provided At The Bottom Of The Chamber. Copper Cooling Coils Are Provided With The Chamber For Easy And Uniform Refrigeration Throughout The Working Chamber And Capable To Come Down The Temperature At 5 Deg.C From The Ambient Temperature. A Turbo Type Blower A Fitted With Suitable Electric Motor Are Provided Inside The Working Chamber To Circulate The Hot And Cold Air For Uniform Temperature At Any Desired Temperature. Temperature Is Controlled By A Pid Controller Relay With An Accuracy Of +/- 1C Or 0.5C Supplied Complete With Neon Indicating Lamps, Main Cord, Switch, Hot And Cold Switches, Supplied With Perforated Aluminium Shelves Operated On 220/230 Volt, Single Phase, And 50 Hz. Ac Mains. Capacity: 6 Cubic Ft. , Chemical Oxygen Demand (Cod Incubator It Is Solid Block Heated Unit With Provision For Samples To Be Digested At A Time In 38Mm Dia. Reaction Vessels With 20Ml Sample Size Of Heat At Temp. 150 °C Controlled By Digital Temp. Indicator Cum Controller. It Has Provision For 6 Samples And Is Supplied With 6 Nos. Glass Reaction Vessels And 6 Nos. Air Condensers. Fitted With A 2 Hour German Timer (Including 6 Samples Test) - To Be Supplied With All Accessories. , Jar Test Apparatus Using Latest Microcontroller, Highly Accurate Digital Rpm Indicator Which Can Be Varied From 25 To 200 Rpm, Digital Timer From 1 To 99 Minutes With Alert Sound. Two Pre-Set Programs Allow Routine Speed And Time Parameters To Be Input And Then Selected By Simply Pressing One Button. Parameters Stored In The Battery Backup Memory. , Ph Meter Type: Digital, Ph Range: 0 To 14, Resolution: 0.01Ph, Compensation: 0 To 80 Degree C , Bod Bottel, Capacity 300 Ml , Modified Proctor Apparatus As Per Is:10074:1982 & 2720 (Part Viii), Specification, Made Of Mild Steel Dia: 150Mm, Height 127.3 Mm, Volume: 2250 Cc, Complete With Base Plate And Collar , Rammers, Weight 4.89 Kg Controlled Drop 410 Mm , Maxwell Reciprocal Theorem Apparatus Maxwell Reciprocal Theorem Apparatus Apparatus Consist Of A Mild Steel Beam 100Cm Long And 1.25Cm X 4Mm In Cross Section With Graduations At Every 10Cm Along The Length. It Should Be Supported On Two Knife Edge Supports 70Cm Apart With A 30Cm Overhang On One Side. Reciprocal Theorem Can Be Verified By Direct Measurements Of The Deflections Of Various Points With The Help Of A Dial Gauge Due To A Load Placed At The Reciprocal Points. A Dial Gauge With 25Mm Travel (With A Magnetic Base) Should Be Supplied With The Apparatus. Apparatus To Be Supplied Should Be Complete With A Supporting Stand And A Set Of Weights. , Two Hinged Arch Apparatus Apparatus Has A Span Of 100Cm And Rise 25Cm. Both Ends Should Have Hinge But One Of The Ends Should Also Be Free To Move Longitudinally. A Lever Arrangement Fitted At This End For The Application Of Known Horizontal Inward Force For Measuring The Horizontal Thrust. Along The Horizontal Span Of The Arch Various Points Are Marked At Equidistant For The Application Of Load. This Being A Statically Indeterminate Structure Of The First Degree. A Dial Gauge With 25Mm Travel (With Magnetic Base) Is To Be Supplied With The Apparatus. Mild Steel Apparatus Complete With A Supporting Stand And A Set Of Weights. , Pin Jointed Truss Apparatus Experimental And Analytical Study Of 1 3 Bar Pin Jointed Truss Apparatus Consists Of Three Suspension Members (Spring Balances) Of Different Stiffness Which Are Jointed At A Point To Form The Redundant Joint. The Upper End Of The Suspension Members Being Tied In A Position To A Vertical Wooden Board. Arrangement Is Provided On A Paper And Also Elongations And Forces In The Suspension Members. , Unsymmetrical Bending Apparatus Apparatus Consist Of An Angle Of Size 1 X 1 X 1/8 Or In Equivalent Metric Units Of Length 80Cm Is Tied As A Cantilever Beam. The Beam Is Fixed At One End Such That The Rotation Of 450 Intervals Can Be Given And Clamped Such That The Principal Axis Of Its Cross-Section May Be Inclined At Any Angle With The Horizontal And Vertical Planes. Also Arrangement Is Provided To Apply Vertical Load At The Free End Of The Cantilever And To Measure Horizontal And Vertical Deflection Of The Free End. A Dial Gauge With Magnetic Base Is Supplied With The Apparatus. , Curved Member Apparatus Apparatus Consists Of A Steel Bar Which Is Used To Make The Different Curved Member Viz. Circle, Semicircle With Straight Arm, A Quadrant Of A Circle And Quadrant Of A Circle With Straight Arm. The Bottom Ends Of The Members Are Fixed To The Base. Under The Application Of Load At Free End, Its Horizontal And Vertical Deflection Can Be Measured With The Help Of Dial Gauges. A Dial Gauge With 25Mm Travel (With A Magnetic Base) Is Supplied With The Apparatus. Apparatus Will Be Supplied Complete With A Supporting Stand And A Set Of Weights , Schimidt Rebound Hammer Test Specification Impact Energy Type N 2.207 Nm (1.63 Ft Lbf) Concrete Compressive 10 To 100 Mpa (1450 To 14500 Psi) Strength Range Types N/L Dimensions Of Housing 55 X 55 X 255Mm (2.16X2.16 X9.84) Weight 570 G Max. Impacts Per Series Memory Capacity Ca. 400 Series Of 10 Impacts (Pc Version Only) Useful Memory Capacity St Version Ca. 200 Series Of 20 Impacts Last 20 Series May Be Reviewed In The Data List Display 17X 71 Pixel, Graphic Battery Life 5000 Impacts Between Charges Charger Connection Usb Type B/C (5V, 100 Ma) Operating Temperature 0 To 50°C (32 To 122°F) Storage Temperature -10 To 70°C (14 To 158°F) Ip Classification Ip54 , Venturi Meter (Bernoullis Theorem Demonstration) Venturi Section Machined From Clear Acrylic, Seven Static Pressure Tappings Plus A Total Head Measurement, Flow Control Valve, Manometer Board With Eight Tubes, Quick-Release Fitting For Easy Connection To Hydraulics Bench. Manometer Range: 0-300 Mm, Number Of Manometer Tubes: 8, Throat Diameter: 10.0 Mm, Upstream Diameter: 25.0 Mm, Upstream Taper: 14°, Downstream Taper: 21, Height: 0.60 M, Width: 0.55 M, Depth: 0.25 M. , Orifice Meter Orifice Discharge Accessory Enables Full Analysis Of The Flow Through Seven Different Orifices Over A Range Of Flow Rates. Determining The Construction And Velocity Coefficients, Calculating The Discharge Coefficient Standard Orifice: Sharp-Edged 13Mm Diameter, Max Head: 365Mm, Traverse Mechanism: Lead Screw With Adjusting Nut Calibrated 0.1Mm Per Division, Height: 0.60 M, Width: 0.33 M, Depth: 0.33 M. , Water Hammer Apparatus A Self-Contained Unit Designed To Demonstrate The Phenomena Of Pipe Surge And Water Hammer. Straight Pipes Are Used, Rather Than A Coiled Arrangement, To Reduce Distortion Of The Pressure Wave. Test Pipes: Stainless Steel, 20.2Mm Inside Diameter, Nominally 3M Long, Surge Shaft: Clear Acrylic, 40Mm Inside Diameter, 800Mm High, Head Tank: Pvc, Capacity 45 Litters, Gross Weight: 420 Kg, Volume: 5 M3, Height:1.865 M, Length: 3.575 M, Depth :0.725 M. , Tilting Flume Apparatus (Adjustable Channel) Tilting Flume Apparatus (Adjustable Channel) Specifications The Tilting Flume Apparatus Should Be Approximately 4 Meter Long Open Channel With 200 Mm Width And 300 Mm Depth. Manual Adjustment Of Slope. Pump Capacity: 1 Hp. Designed To Conduct Various Experiments At Various Bed Slopes With Mechanism To Read The Bed Slope. Screw Jack Arrangement Is Provided To Adjust The Bed Slope Of The Channel As Desired. The Flume Has A Perspex Window At Specific Spots Where Structure Such As Weir, Spillway, Or V Notch Will Be Installed To Visualize The Flow Over Models Fixed In Flume. Trolley Mounted Point Gauge For Level Measurement Of Water. Trolley Can Be Traversed For Whole Length Of Flume. The Mechanism Should Be Able To Read Y And Z Coordinates Along With The X-Coordinate. The Flume Is Provided With Gates On Upstream & Downstream Side To Control The Flow. Various Experiments Like Flow In Open Channel, Hydraulic Jump, And Calibration Of Weirs, Notches And Venturi Flume Can Be Conducted. An Orifice Meter With Manometer Is Provided To Determine The Discharge Provided To The Open Channel By The Feeder Pipe. This Is Used For The Calibration Of The Weirs And Notches. The Set Up Should Be Provided With A Pump Of Adequate Capacity For Recalculating The Water Supply. It Should Be Provided With Collecting And Supply Tank. Stop Watch Be Provided For Recording Time And With Lab Manual. Scope Of Experimentations: • To Calibrate The Notches & Weirs. • To Study About Hydraulic Jump. • To Study Flow Through Venturi Flume. To Study Specific Energy Curves , Metacentric Height Apparatus Determining The Centre Of Gravity Of The Pontoon, Determining The Metacentric Height And From This The Position Of The Metacentre For The Pontoon, Varying The Metacentric Height With Angle Of Heel, Max Angle Of Heel: ±13°, Corresponding Linear Dimension: ±90Mm, Height: 0.475 M, Width: 0.35 M, Depth: 0.20 M. , Pitot Tube Apparatus Description: The Designed Pitot Tube Unit The Change In Flow Speed Within A Tube Can Be Determined. The Pitot Static Tube Can Be Moved Across The Whole Cross- Section Of The Tube, And Thus To Measure The Pressure Profile. This Tube Is Connected To Manometers Via Hoses. The Pitot Tube Can Be Moved Across The Cross-Section Of The Pipe In Order To Measure The Dynamic Head Profile. The Position Of The Measuring Tip Relative To The Wall Of The Pipe Can Be Read On A Scale. The Pitot Tube Is Connected To A Pressurized Water Manometer To Measure The Differential Head Across The Pitot Static Tube. The Position Of The Measuring Head Relative To The Bottom Edge Of The Tube Can Be Measured On A Scale. The Water Supply Can Come From The Hydraulics Bench Or From The Basic Hydraulic Feed System. The Pitot Tube Can Be Moved Across The Cross-Section Of The Pipe In Order To Measure The Dynamic Head Profile. Features: •Study Of The Function Of A Pitot Static Tube. •To Use A Pitot Static Tube. •Determination Of Tube Flow Speed Profiles. •Demonstration That The Flow Speed Is Proportional To The Pressure Difference Between The Total Pressure And The Static Pressure. •Error Determination In Flow Measurements Using The Pitot Tube As Measurement Instrument. • Factor Cd Determination In The Pitot Tube. • Operation Of A Pitot Static Tube And Pressurized Water Manometer • Velocity Flow Profile In A Pipe • Demonstration That The Fluid Velocity Is Proportional To The Square Root Of The Head Difference Between The Total Head And The Static Head Specification: • Pitot Static Tube: Head Diameter: 2.5 Mm. • Transparent Pipe: 32 Mm. Internal Diameter • Transparent Pipe: 430-Mm.-Length Approx. • Hose Connections. • Water Manometer, 500 Mm. Length. • Easy And Quick Coupling System • Built-In. Anodized Aluminum Structure And Panel Of Painted Steel. • Dimensions And Weight • L X W X H: 800-X600 X 600 Mm • Weight: 40Kg
Contract Date: Feb 19, 2026 Contract Value : 34.03 Lakh
Local Bodies No of Bidders 4
23.
Educational and Research Institute #9596587 AOC
E-Tender For Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Of Mechanical Engineering, Civil Engineering, Electrical Engineering, Electronics And Telecommunication, Physics Laboratory And Chemistry Laboratory Of K.G. Engineering Institute, West Bengal--1 Colorimeter 2 Ph Meter 3 Conductivity Meter 4 Redwood Viscometer 5 Ables Flash Point Apparatus 6 Inverse Square Law And Compare The Difference In Output Luminisence Of Incandescent, Fluroscent, Cfl Study Panel 7 Schering Bridge 8 A Panel Containing All Individual Pilot Devices Fully Operational , Their No, Nc Contact Can Be Used In The Circuit And Their Operation Can Be Monitored Through Output Led Indication Light 9 Variable Inductance Box 10 Trainer Kit To Study Series Inverter Using Scr 11 Panel For Speed Control Of Ac Induction Motor By V / F 12 Digital Ic Trainer 13 1. To Study Dol Starter Using Induction Motor 2. Automatic Star Delta Starter Using Plc 3. Speed Control Of Dc Shunt Motor With Pid Control Using Plc4. Control Circuit Operation Of 3 Sequential Motor Operation Using Plc 14 Motor Braking Method System 15 To Calibrate Single Phase Energy Meter Using Resistive And Inductive Loads. 16 Demonstrate Different System Faults Using Dc Network Analyser. 17 Single Stage Rc Coupled Fet Amplifier 18 Anderson Bridge 19 To Demonstrate D / A Conversion Using Kit 20 To Demonstrate A / D Conversion Using Kit 21 1. To Fabricate An Op-Amp Integrator, Determine Its Amplitude, Phase Relation With Input, Duration Of Output Pulse Compared To Input. 2. To Fabricate An Op-Amp Differentiator, Determine Its Amplitude, Phase Relation With Input, Duration Of Output Pulse Compared To Input For A Triangular Input. 22 To Fabricated With Ic-555 ( A ) Astable Multivibrator & To Determine Duration Of High Pulse And Duty Cycle. ( B ) Monostable Multivibrator & To Determine The Duration Of High And Low Pulses Triggered Condition With Different R-C Values.A Pulse Width Modulation Circuit To Observe The Variation Of Duration Of High Pulse With The Various Values Of Control Voltage At Control Input Terminal Of Ic-555. 23 Ups Trainer Kit 24 To Determine Candle Power Of A Lamp In Comparison To Standard C.P. Of Lamp By Optical Bench Method. 25 Bh Curve Apparatus 26 Digital Multimeter ( 200 Mv To 1000 V Dc, 200Mv To 500 V Ac ; 10A, 1Ωto 20Mω , 1000 Μf, Transistor & Diode Testing ) 27 Variable Dcpower Supply ( Dual Supply , 0V - ±30V , 2A , ±3 -±15V , 1A, 5V, 5A Fixed, Digital Display ) 28 Diode Trainer 29 Rectifier Trainer 30 Oscillator Trainer 31 Multivibrator Trainer 32 Amplifier Trainer : Bjt 33 Feedback Amplifier Trainer 34 Tuned Amplifier Trainer 35 Clipper & Clamper Trainer 36 Trainer Kit For Two Stage Rc Coupled Transistorized Amplifier : 37 Trainer Kit Transistorized Complimentary Symmetry Push Pull Amplifier : 38 Frequency Modulation / Demoduiation Trainer 39 Ask / Psk / Fsk Modulation And Demodulation Kit 40 Pulse Code Demodulation System Trainer 41 Function Generator 42 Trainer Kit To Study Reverse Recovery Characteristics Of Power Diodes 43 Single Phase Reectifier &Controlled Rectifier Ckt Using Scr Kit 44 Dc Motor Thyristorised Speed Control Trainerkit 45 Single Phase Bridge Invertertrainer 46 Step Up Chopper Trainer 47 Smps Trainer 48 Single Phase Controlled Rectifier Trainer Using Scr 49 Advanced 8051 Microcontroller Tariner With Pc And Accessories 50 Advance Microprocessor Trainer 8086 / 88 With Pc And Accessories 51 Strain Gauge Trainer Kit 52 Lvdt Trainer Kit 53 Thermocouple Trainer Kit 54 Thermister Trainer Kit 55 Rtd Trainer Kit 56 Calibration Of Compression Testing Machine ( 1000 Kn Capacity ) 57 Replacement Of Touch Pannel Box Of Compression Testing Machine ( 2000 Kn Capacity ) 58 Replacement Of Sensorof Compression Testing Machine ( 2000 Kn Capacity ) 59 Repair And Servicing Of Old Universal Testing Machine 60 Concrete Core Cutter ( Portable ) 61 Rebar Locator ( Metric Scale Hand-Held Unit With Charger In Carrying Case ) / Profometer 62 Digital Rebound Hammer With Calibration Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing ) 63 Ductility Testing Apparatus 64 Metric Chain 20 M 65 Metric Chain 30 M 66 Ranging Rod ( Made Of G.I. / M.S. ) 67 Total Station 68 Permeability Test Apparatus With Accessories 69 Liquid Limit Device, Motorised 70 Triaxial Test ( With Pore Pressure Arrangement, Digital ) 71 Unconfined Compression Test Apparatus 72 Cbr Test Apparatus 73 Sand Replacement Apparatus [ Big ] 74 Sand Replacement Apparatus [ Small ] 75 Digital Analytical Balance ( 220 G / 0.1Mg ) 76 Electronic Balance, Capacity 2 Kg. 77 Electronic Digital Balance ( 25Kg / 1G ) 78 Jar Test Apparatus ( Digital ) 79 Epicyclic Gear Train & Holding Torque Apparatus 80 Rope Brake Dynamometer 81 Stainless Steel Four Bar Chain Mechanism 82 Cam Analysis Apparatus 83 Universal Governor 84 Impact Of Jet On Vanes Apparatus 85 Flow Over Notch Apparatus 86 Pelton Wheel Turbine 87 Reciprocating Pump Test Rig 88 Centrifugal Pump Test Rig 89 Bernoullis Theorem Apparatus 90 Vmc Double Pallet Kira Vertical Machining Center 91 Fostex Universal Dividing Head 92 Digital Rockwell Cum Brinell Tester 93 Izod Charpy Impact Testing Machine 94 Torsion Testing Machine 95 Mild Steel Universal Testing Machine 96 Tools For Lathe And Milling 97 Vapour Compression Refrigeration Test Rig 98 Portable Tig And Arc Welding Machine Setup With Argon Cylinder And Regulator 99 Separating Throttling Calorimeter For Dryness Fraction Measurement 100 Models Of Lancashire, Cochran, Babcock And Wilcox Boiler 101 Slide Calipers / Vernier Calipers 102 Screw Gauge / Micrometer 103 Optical Bench Set-Up 104 Hookes Law Apparatus 105 Friction Table Set-Up 106 Spring Balance ( Hanging Type With Rectangular Shape ) 107 Retort Stand 108 Laboratory Flywheel ( Wall Mountable ) 109 Linear Expansion Apparatus / Pullingers Apparatus ( Vertical Type ) 110 Steam Boiler With Bung / Stopper 111 Electrical Bunsen Burner 112 Lpg Gas Hose Pipe 113 Rubber Tube 114 Fortin’S Barometer With Case 115 Ohms Law Apparatus 116 Kirchoffs Law Apparatus 117 Resistance Box 118 Fractional Resistance Box 119 Galvanometer To Ammeter Box Set-Up 120 Galvanometer To Voltmeter Box Set-Up 121 P-N Junction Diode Set-Up 122 Galvanometer 123 Spirit Level 124 Multimeter 125 Screwdriver Kit
Contract Date: Nov 14, 2024 Contract Value : 64.02 Lakh
Government Departments No of Bidders 15
West Bengal View Result →
24.
Rural Development #9589409 AOC
Tender For Liquid Waste Management Scheme At Dahiwel Tal Sakri - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 0 to 1.5 m 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 125 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 73 Providing Energy Meter Application Fees Energy Meter Fee
Contract Date: Feb 17, 2026 Contract Value : 46.51 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
25.
Rural Development #9589408 AOC
Tender For Liquid Waste Management Scheme Dighave Tal Sakri Dist Dhule - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 75 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018
Contract Date: Feb 17, 2026 Contract Value : 34.89 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
26.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
27.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
28.
Agriculture #9519259 Technical Bid
Tender For Construction Of Divisional Office Building Vellore At Fsd Sevur Tamil Nadu Region (Recall).; 1 Civil ( S.No.1-96) Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as directed by Engineer-in-Charge. a) All kind of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Supplying and filling in plinth withsand under floors, including watering, ramming,consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Treatment of soil using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1)concrete of m30 grade withminimum cementcontent of 350 kg /cuma) All works upto plinth level 9 b)All works above plinth level upto floor V level 10 Centering and shuttering including strutting, propping etc. and removal of form for all heights.a) Foundations, footings, bases of columns. etc. for mass concrete 11 b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 c) Suspended floors, roofs, landings, balconies and access platform 13 d) Columns, Pillars, Piers, Abutments, Posts and Struts 14 Stairs, (excluding landings) except spiral-staircases 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a)Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a)Cement mortar 1:4 (1 cement :4 coarse sand) 19 12 mm cement plaster a) 1:6(1 cement: 6 fine sand) 20 15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:4 (1 cement: 4 fine sand) 21 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 22 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of the tile 600x600 mm 24 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved brand & manufacturer, in all colours & shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement & matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size b) Size of Tile 600x600 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a)Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 27 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 28 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.a) On steel work 29 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 30 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/ wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 33 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 34 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 35 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 37 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified 38 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof Silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately.Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3(ii)Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 39 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class Acategorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a)Frame size 50 x 125 mm 40 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) a)35 mm thick 41 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 42 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 43 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only 44 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters. 45 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 46 Providng & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes 47 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure ation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for cupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and formation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for ualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a ssure range 50 kpa to 240 kpa (35psi) upto 2000 mlNote:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 48 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 50 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 51 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 52 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.a)200 mm 53 Providing and fixing Godrej Stainless Steel Glass to Glass Round Lock 7780 complete as per direction of Engineer-incharge. 54 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 56 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and pair of lever handles of approved quality with necessary screws etc. complete. 57 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 58 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 59 Full ht. 75 mm. thk Solid Partitions/Semi Glazed Partitions with both side 12mm commercial plywood and 1mm thick Laminate & Providing Aluminium frame of size 50x50x1.8 mm thk (finished) comprising of horizontals and verticals at, 600 mm c/c ,vertically and horizontally fixed firmly to walls / floors / RCC roof etc. Alternate vertical members to go upto RCC ceiling and firmly fixed. Providing 8 mm thk. ISI grade plywood of approved make , finished / fixed with 1 mm thick laminate of approved make & shade fixed with adhesive , fixed on both sides of the partition framework. The laminate to be fixed with adhesive on both sides of the partition upto False ceiling level. 60 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer ofplaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 61 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 62 Providing & applying patterened texture work on extrenal wall with birla or equivalent brand putty on plastered surface as approved by Engineer-in-Charge, 63 Providing and fixing of FRP Security Cabin in Size of 2.5x2.5x2.5m with M.S frame structure and covered by FRP Pannel and FRP Pyramid shape Plane Roof. FRP Door thick - 20mm (6x2) With, ALdrop, Handel, & 3 Nos. SS Ingies.Inside & Outside writing Counter, Size- L-4x W-11Electrical Point- Inside &Outside Bulb Point, 1plug, 3 Switch,Cloth Hanger- 01Nos as per Engineer in Charge. 64 PLUMBING Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : A) W.C. pan with ISI marked white solid plastic seat and lid 65 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 225 mm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (Size 600x450x200 mm) 67 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 68 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 69 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 70 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 71 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions) 72 Providing and fixing toilet paper holder : C.P. brass 73 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Sand cast iron S&S as per IS-1729 74 Providing and fixing soil,waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 75mm dia 75 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Hubles centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 76 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 78 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal Inner dia Pipes 79 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes 80 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes 81 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 82 Providing and placing on terrace (at all floor levels) polythylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 83 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 84 EXTERNAL INFRASTRUCTUREConstruction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge. a)With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 85 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 86 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size of 100x0.375x0.20 87 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 88 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm 89 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 90 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 91 Fine dressing of the ground 92 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 93 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 94 Providing and stacking of Plumeria acutifolia of height 120-135 cm. with 2-3 branches in HDPE bag of size 30 cm as per direction of the officer-in-charge. 95 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 96 Washingtonia filifea palm stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bag 97 Electrical ( S.No.97-211) Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work3 1/2 X 120 Sq.mm 98 3 1/2 X 70 Sq.mm 99 4 X 25 Sq.mm 100 4 X 10 Sq.mm 101 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 102 150 mm width X 50 mm depth X 1.6 mm thickness 103 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 104 150 mm width X 50 mm depth X 1.6 mm thickness 105 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 106 150 mm width X 50 mm depth X 1.6 mm thickness 107 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 108 Supplying and fixing of light class G.I. pipe of 100 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective coveringUpto 35 sq. mm 110 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185sq. mm 111 Up to 35 Sq mm 112 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 113 Upto 35 sq. mm (clamped with 1mm thick saddle) 114 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as requiredAbove 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 115 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 116 Upto 35 sq. mm (clamped with 1mm thick saddle) 117 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) 118 3½ X 70 sq. mm (38mm) 119 4 X 25 sq. mm (28mm) 120 4 X 10sq. mm (25mm) 121 Supplying and fixing hot press molded SMC box of size 140x140x95 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of 3 way connectors of suitable rating ,providing and fixing 6A C curve MCB, terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required 122 Supplying and fixing of follwing way sueface / recess mounting vertical type , 415 V , TPN MCB distribution board of sheet steel, dust protected , duly painted , inclusive of 200 A tinned copper bus bar , common neutral link , earth bar , for mounting MCBs (but without MCBs and incomer ) as required4 way ( 4 + 12 ) , Double door 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 124 6 way (4 + 18), Double door 125 4 way (4 + 12 ), Double door 126 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 127 Triple pole 128 Supplying and fixing following rating, four pole, 415V isolator in the existing MCB DB complete with connection , testing and commissioning etc. as required 40A 129 63 A 130 Providing and fixing following rating and breaking capacity and pole MCCb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections , etc as required100 A, 30 KA, FP MCCB 131 Supplying & fixing suitable size GI box with modular plate and cover in fornt on surface or in recess including providing and fixing 25A modular socketoutlet and 25A modular SP MCB , Ccurve includingconnections , painting etc , as required . 132 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 136 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 137 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 138 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 3pin 5/6 A modular socket outlet and 5/6 modular swith connections etc.as required . 139 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 6pin 5/6 A & 15/16 modular socket outlet and 5/6 modular swith connections etc.as required . 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 141 3 pin 5/6 A socket outlet 142 15/16 A switch 143 6 pin 15/16 A socket outlet 144 Telephone socket outlet 145 RJ45 computer socket cat 6 146 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mm X 125mm) 147 6 Module (200mm X 75mm) 148 1 or 2 Module (75mm X 75mm) 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 150 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 151 2 run of cable 152 3 run of cable 153 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair 154 2 Pair 155 Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 156 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 157 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess For connections etc. as required. 158 Providing and fixing 6 SWG dia G.I. wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 159 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 160 Providing and fixing 4.00 mm dia copper wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 161 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick . base plate including holes etc. complete as required. 162 Jointing copper / G.I tape (with another copper / G.I tape, base of the final or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required 163 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required (For horizontal run) 164 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required(For vertical run) 165 Providing and fixing testing joint , made of 20 mm X 3 mm thick G.I. strip , 125mm long , with 4 Each. of G.I bolts, nuts, chuck nuts and spring washers etc. complete as required. 166 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required . 167 Supplying, installation, Testing and commissioning of 90W LED Street light fittingmade up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 in the existing streetlight pole with suitable clamps and nut bolts including giving connection etc., at site of work as required 168 Supplying, installation, Testing and commissioning of 36 watt 2X2 LED flat panel recess mounting luminaire with high brightness LED as light source, suitable for Armstrong/Grid ceiling and fixing on ceiling with suitable hanging chains, clamps and nut bolts including giving connection testing etc., at site of work as required 169 Supplying, installation, Testing and commissioning of 12 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 170 Supplying, installation, Testing and commissioning of 18 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 171 Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with Al body, PC diffuser and inbuilt driver along with Highly robust box type luminare suitable for single T8 LED tube and fixing on wall/ceiling by using necessary clamps etc., at the site of work as required 172 Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for single T8 LED tubelight and fixing on wall/truss by using necessary clamps etc. as required 173 Supply and fixing of7W LED surface mounted LED mirror light luminarie complete and fixing on wall by using necessary clamps etc., at the site of work as required 174 Supplying, installation, Testing and commissioning of 24 watt square surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 175 Supplying, installation, Testing and commissioning of 40 watt LED 5700K Post top lantern IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required 176 Supply and fixing of 10W pressure die cast aluminium housing Bulk Head LED fitting with IP66 protected withPVC unsheathed copper leads from terminals to the fitting and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 177 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR Item for BEE 5 star rated Ceiling fan with Brush Less Direct Current (BLDC) motor 178 Supplying and fixing of single phase, 230V,50Hz, 1800 rpm, 200mm dia sweep, 5 blade Exhaust fan with bird screen for protection against birds & Foreign material and fixing on the wall surface including giving connections etc. at site of work as required 179 Supply of 6 mtr high hot dipped galvanised octagonal poles with 130 mm bottom dia and 70 mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x16 mm thick along with 4 nos of M20x600 mm high J type 8 EN grade foundation bolts along with template to fix the pole to the foundation and supply of 1 mtr long hot dipped galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70 mm dia for mounting the street light fixture 180 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregrate 40mm nominal size) foundation including excavation and refliing etc. as required 181 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.2 TR 182 2.0 TR 183 2.8 TR 184 Supply, Installation, Testing and Commissioning of 1.5 Ton/4500 Kcal/hr, 5 Star Rating Inverter technology High wall split type Air Conditioner with minimum of 3 metre length of copper Refrigerant piping with insulation and electrical cable complete with indoor unit (IDU), Outdoor unit (ODU) suitable For 230V +10% of 50 Hz, single phase AC supply and Fixing on the wall surface including giving connections etc. at site of work as required 185 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 186 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required19 mm dia (OD) (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation 187 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 188 Supply and fixing of FP sheet enclosure on surface/recess along with 63A FP C curve MCB complete with connections, testing and commissioning etc. as required 189 Design, Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable For 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity For Phases & neutral (min. of 250A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. 190 Design, Fabrication, Supplying, Installation, Testing and commissioning of 315A near by control box with 4 pole 315 A MCCB switch with front handleDust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral (min. of 250 A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge 191 Design, Fabrication, Supply, installation, testing and commissioning of 30KVAR Automatic power factor correction panel (APFC) with 6steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment For each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 6 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. capacStart, Stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus For the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., complete 192 Supply, Erection, testing and commisioning of 82.5KVA/66 KW Diesel Generating Set (as per the latest CPCB IV+ norms) comprising of Water Cooled, 4 cylinder Diesel engine developing minimum of 102 BHP with electric start compression ignition 4 stroke designed to run continuously at at 1500 RPM. Coupled to Alternator rated at 1500 rpm, 415 Volts, 0.8 power factor, 50 Hz, three phase supply, self-excited and self-regulated, brushless, floor mounted with ball or bearings on end shields and fuel Tank of minimum 150 Ltrs capacity with Standard Control Panel with Breaker, Batteries and Acoustic Enclosure including Transportation, loading-Unloading, UG cable laying from generator to panel, earth strips connections etc., at the site of work as required (Model should have minimum 2 year warranty) 193 Supply, Installation, Testing and Commissioning of 15kVA DOUBLE CONVERSION 3 phase input,3 phase output True Sinewave ONLINE UPS with 0.99 power factor including stand along with supply and erection of 12V/26AH SMF Batteries (30mis back up) of 30 nos.including providing necessary connections etc. complete as required 194 Supplying, fixing and testing of CO2 fire extinguisher of 4.5 kg capacity with hose and horn confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 195 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 10 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 196 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 6 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 197 Supplying and fixing of MS angle fire bucket stand with 03 Each fire buckets of 10 litre capacity, at the site of work as required. 198 Supplying, installation, testing and commissioning ofsmoke detection system with minimum of 36 Each conventional type photo-electric smoke detectors, 2x1.5 sq.mm fire resistant armoured cable(red colour), 6 Each Manual Call points, 6 Each Hooters complete with 2 zone fire alarm panel etc at site of work as required 199 Supply, Installation, Testing and commissioning of 16 channel 4 SATA NVR, with 4T Hard Disk Drive 1 Each, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface For HDD connection, Support upto 10TB capacity For each HDD, Smart search For efficient playback. and smart playback to improve the playback efficiency, Supports VCA search For fire/ship/temperature /temperature difference detection triggered video files, POS inFormation overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect For easy network management, 2 Gigabit Ethernet network interfaces 200 Supply ,Testing and Commissioning of 4MP Infra Red Dom Camera and fixing the same on wall/ceiling including providing necessary connections etc. complete as required 201 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse 202 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3Each m) USB -3Each n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37) 203 Supply, laying and termination of high quality Un- Armoured Optical Fiber (48 Fibers) along with the all accessories connectors, switches etc complete as required 204 Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer 205 Supply, fixing and termination of high quality floor mounted type 24U floor mountable powder coated Rack with 3x5A Power Manager, 1 position fan, min 1 nos of shelf, Front Glass double door with Lock & key with suitable network port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer in charge 206 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with followingcomponents complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 207 Supply, Erection, Testing and Commissioning of new 160 kVA, 11kV/433V, 3-Phase, 50 Hz, ONAN Cooled, Copper wound Transformer with Energy Efficient level-I, Dyn11 vector group, first fill of oil, Bushing on HT side & Cable box on LT side, off circuit tappings of +5% to -10% in steps of 2.5% with standard fittings confirming to IS 1180, including transportation of the machine from OEM factory to site, mechanized mounting of transformer in the DT structure, providing necessary cable end terminations (LV side), connection of 4 SWG copper down conductor (HV side), body and neutral earth connections, insulation resistance testing and certification of the same etc. as required 208 Providing new service connection to the Divisional Office building by preparation of drawings, coordinating with EB, deposit amount/ statutory charges to be paid to EB for supply and fixing of poles/DT structures, overhead ACSR conductors, associated accessories, including any additional works as per the instruction of EB/FCI engineer-incharge etc. as required. (Deposit Amount/Statutory Fees will be paid by FCI as per actual only) 209 Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conForming to IS: 694in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 210 Supply,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 211 Supply of 2m x 1m x 3mm thick corrugated rubber mat as required conforming to relevant ISI specification suitable for electrical application
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
29.
Public Administrative Department #9493970 Technical Bid
Tender For Place making work from Naja Market Novelty Square to Municipal Corporation office in Hazratganj - DISMANTLING WORK 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 3 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (in cement mortar) 5 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 6 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (BITUMINOUS ROAD) 7 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 8 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 9 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge 10 CIVIL WORK 11 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 12 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. 13 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc for mass concrete 15 Providing & Laying Designer Pavers 100mm x 100mm with thickness ranging from 70-90mm of approved shape and complete as per direction of Engineer-in- Charge. including transport ,loading ,unloading and conveyance of material from available source to work site, including labour charges for fixing and pointing etc., complete 16 Sand FillingFilling in foundation trenches as per drawing and technical specifications clause 305.3.9 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 19 Cement mortar 1:3 (1 cement :3 coarse sand) 20 12 mm cement plaster of mix : 21 1:4 (1 cement: 4 coarse sand) 22 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 23 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 24 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 25 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand): 25mm thick 26 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 27 Supply and installation of 60 L: AUX Waste Bin of material Stainless Style with Contemporary Mounting: Root fixed, Surface/baseplate fixed, wall/post mounted with Features: Ashtray, complete with foundation as per the direction of the Engineer in charge 28 Providing and laying drain gratings on both sides of the road anlong with tree grating wherever required. 29 Drain Grating - FRP GRATING (DRAIN)SIZE: 366 x 1001 x 30 H MMTHICKNESS: 6/7 MM 30 Tree Grating - SIZE: 800 x 800 x 400 (Inner Dia’) MMTHICKNESS: 30 MM 31 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mm 32 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia 34 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications 35 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 36 Centering and shuttering including strutting, propping etc. and removal of form for : Walls 37 Steel in kg 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 39 For vertical surface two coats @ 0.70 kg per sqm per coat 40 For horizontal surface one coat @1.10 kg per sqm. 41 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineerin-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately). 12 mm thick one side Pre-laminated particle board (decorative lamination on oneside and other sides balancing lamination) grade -1, medium density flat pressed,three layer particle board FPT - I or graded wood particle board FPT-1 conformingto IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 andpre-laminated conforming to IS : 12823, Grade -1, Type II marked 42 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia 43 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate 44 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia 45 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness5.40 mm 46 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 47 brick ballast 40 mm class 150 48 brick ballast 40 mm class 150 49 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications including, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge 50 Supply and fixing of Bollard made from mid steel with CNC machine finishingwith 140mm outer diameter , thickness of 3mm r and 1100mm Height . Expose height 900mm from above Ground level and fixed the remaining 200mm below the GL. three number of circular rib of R06mm radius are provided at the top . The whole product is power coated black colour as per standard recommendation of Engineer. For fixing the Bollards with M10 cement concrete footing of minimum dimension 20cmx20cmx20cm,with base plate, anchor rods complete. 51 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 52 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applyingHeat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee Support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge. 53 Mandatory/ Regulatory sign boards of 900 mm diametrewith support length of 3750 mm 54 Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size, PSR 55 Signage-A Informative Signage of Sandstone/Marble of size (1200x2100)MMvisibly from both side, PSR 56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab except colour of Black, Cherry/Ruby Red or equivalent 57 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 58 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 59 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 60 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 61 Supplying, fixing and commissioning of Hydraulic (Retractable) Bollards as per specification 62 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 63 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 64 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 65 Labour rate for the mentioned item. Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundationbolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. 66 Providing & fixing ofConcrete Drain Covers Sandstone Colour550X750X50MM Colour: Sandstone Ultra High Performance Pigmented Concrete With Steel Fiber Reinforcement Load Capacity Suitable for 10 Tonne Pigmented Concrete Bayferrox Lanxess Fe203 Colour Index 77491.0000etc all complete in direction of engineer in charge 67 Providing & fixing of Concrete drain cover Concrete Drain Covers Sandstone Colour 550X750X50MM Ultra High Performance Pigmented Concrete With Steel Fiber Reinforcement Load Capacity Suitable for 40 Tonne Vehicle Passing Bayferrox Lanxess Fe203 Colour Index 77491.0000 etc all complete in direction of engineer in charge 68 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastenersat both ends. The work shall be executed as perdrawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 69 PLUMBING OF AREA- HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT 70 SANITARY FIXTURES & ACCESSORIES 71 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 72 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White 73 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require 74 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 75 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 76 32 mm dia (for wash basin) 77 Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 78 Providing & fixingtoilet paper holder. C.P. Brass 79 WATER SUPPLY PIPES AND FITTINGS 80 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 81 Internal work exposed on wall 82 40mm nominal outer dia pipes 83 50mm nominal outer dia pipes 84 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 85 Concealed work including cutting chase and making good the wall etc. 86 15mm nominal outer dia pipes 87 20mm nominal outer dia pipes 88 25mm nominal outer dia pipes 89 32mm nominal outer dia pipes 90 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 91 40 mm nominal bore 92 50 mm nominal bore 93 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions.45 cm length: 15mm nominal bore 94 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 95 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. 96 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 97 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. 98 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 99 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 100 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 101 150 x 100 mm. size P type 102 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 103 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 104 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 105 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 106 PN - 10 Pipe, 50 mm OD (SDR-11) 107 PN - 10 Pipe, 75 mm OD (SDR-11) 108 PN - 10 Pipe, 110 mm OD (SDR-11) 109 TOTAL ( SCHEDULED ITEM ) 110 PART B(NON SCHEDULED ITEMS - AS PER MARKET RATES) 111 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 112 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) 113 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 114 P-Trap type Floor Trap 110 x 75 mm 115 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 116 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 117 C. INTERNAL ELECTRICAL WORKS -HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT 118 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 119 Group A 120 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required 121 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 122 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 123 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 124 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 125 Supply and drawing co-axal TV cable RG-6 Grade, 07 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PCV sheath in the axisting surface/recessed steel/PVC conduite as required. 126 1 Pair, 0.5mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, Telephone cable 127 Supplying and fixing following Suitable size GI Box with Moudular plate and cover infront on surface or recess, including providing and fixing 2 nos 3 pin 5/6 A moduler socket outlet and 2 nos. 5/6 A moduler switch, connection etc. as required. ( for light pluges to be used in non residentions, painting etc. as required. 128 Supplying and fixing following Suitable size GI Box with Moudular plat and cover infront on surface or recess, including providing and fixing 25 A moduler socket outlet and 25 A moduler SP MCB C Curve including connections, painting etc. as required. 129 Supplying and fixing PVC batten/ angle holder including connections etc as required. 130 Supply and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 131 5/6 A Switch 132 2 way 5/6 A switch 133 Telephone socket outlet 134 TV Antenna socket outlet 135 Bell Push 136 Supplying and fixing following size/ modules, GI box along withmodular base & cover plate for modular switches in recess etc as required. 137 1 or 2 Module (75mmX75mm) 138 3 Module 100mmX75mm) 139 4 Module 125mmX75mm) 140 6 Module 200mmX75mm) 141 8 Module 125mmX125mm) 142 12 Module 200mmX150mm) 143 Supplying and fixing following modular base & cover plate on existing moduler metal boxes etc. as required. 144 1 or 2 Module 145 3 Module 146 4 Module 147 6 Module 148 8 Module 149 12 Module 150 Supplying and fixing of following sizes of pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 151 25mm 152 32mm 153 Supply, installation, testing and commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with brush less direct current (BLDC) Motor, class of insulation: B, 3 nos. Blades 30cm long down rod, 2 nos, canopies shackle kit, safety rope, copper winding, power factor not less than 0.9 service value (CM/M/W) Minimum 6.00, air delivery minimus 210 cm/min 350 rpm (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washer, temperaure rise = 75Degree C (max.), insulation resistance more than 2 mega ohm, Suitable for 230 V, 50Hz single phase AC supply, earthing etc. Complete as required. 154 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as 155 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. asrequired. 156 Supply and fixing call bell/Buzzer suitable for single phase,230V, Complete as required. 157 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 158 Supplying and fixing following way, Horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 159 4 way(4+12) , Double door 160 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 161 16 way , Double door 162 Supply andfixing following rating, double pole, 240 V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 163 40 A 164 Supply andfixing following rating, four pole, 415 V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 165 63 A 166 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 167 Single Pole 168 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 169 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe et 170 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as 171 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 172 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 173 PART B - NON - SCHEDULED ITEMS (AS PER MARKET RATES ) 174 Supply & erection of AC 230/250 volts 50 hz Exhaust fans including provding nut bolts mounting frame and other accessories including connection etc complete as required as per direction of E /I make:- Havells / Cromption / USHA 175 300 mm Sweep 900 RPM 176 Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA 177 Supply & fixing of following Telephone outlet 178 Supply & installation of CCTV / Suvillance system. (Honeywell 20 channel NVR full HD IP based- 01 nos, IP Honeywell dome camera 2MP with night vision- 8 nos., IP Honeywell 2 MP HD Bullet camera with night vision- 8 nos.) 179 Supply of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, including tube on surface complete in all respect. 180 1 X 22 W 181 Supply ofrecess/Surface/Pendent mounting round 12 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. (Make: Wipro) 182 LED Fancy Gate Light, Aluminium, 12 W 183 Earth work in excavation bymechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.All kinds of soil 184 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5kmalso includingrammingandwateringoftheearthinlayersnot exceeding20cmintrenches,plinth,sidesoffoundationetc.complete. 185 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 186 Providingandlayinginpositioncementconcreteofspecified grade excluding the cost of centering and shuttering - All work uptoplinthlevel:1:3:6(1Cement:3coarsesand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 187 Brick work with common burnt clay F.P.S. (non modular) bricks of class -150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 188 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. M-25 Grade Concrete 189 SteelreinforcementforR.C.C.workincludingstraightening, cutting,bending,placinginpositionandbindingallcomplete Thermo-Mechanically Treated bars of grade Fe-500D or more 190 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 191 Providingandapplyingwhitecementbasedputtyofaverage thickness1 mm, of approved brandand manufacturer,over the plasteredwallsurfacetopreparethesurfaceevenandsmooth 192 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm 193 ProvidingandlayingfactorymadechamferededgeCement Concretepaverblocksin footpath, parks,lawns, driveways or light trafficparking etc,of requiredstrength, thickness& size/ shape, made by table vibratory method using PU mould, laid in requiredcolour&patternover50mmthickcompactedbedof sand, compacting and proper embedding/laying of inter locking paverblocksintothesandbeddinglayerthroughvibratory compactionby usingplatevibrator,fillingthe jointswithsand andcuttingofpaverblocksasperrequiredsizeandpattern, finishing and sweeping extra sand. complete all as per directionof Engineer-in-Charge. 194 60mm thick cement concrete paver block of M-35 gradewith approved colour, design & pattern (Square and Rectangular shape) 195 80mmthickC.C.paverblockofM-35gradewithapproved color design and pattern.(Square and Rectangular shape) 196 Providing and laying matt finished vitrified tile of size 100x100x16mmhavingwaterabsorptionlessthan0.5%and conformingtoIS:15622ofapprovedmakeinallcoloursand shadesinoutdoorfloorssuchasfootpath,courtyardmulti modelsetc.,laidon20mmthickbaseofcementmortar1:4 (1cement:4coarsesand)inallshapes&patternsincluding groutingthejointswithwhitecementmixedwithmatching pigments etc. complete as direction of Engineer-in-Charge. 197 Providingandlayinginpositonreadymixedorsitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate and aggregate derived from natural sources,PortlandPozzolana/OrdinaryPortland/PortlandSlag cement,admixtures in recommended proportons as per IS:9103 to accelerate / retard sieving of concrete, to improve durability and workabilitywithoutimpairingstrength;includingpumpingof concretetositeoflaying,curing,carriageforallleads;but excludingthecostofcentering,shufering,fnishing andreinforcementasperdirectonoftheengineer-in-charge;for the following grades of concrete.Note: Extra cement up to 10% of the minimumspecified cement content in design mix shall be payableseparately.Incasethecementcontentindesignmix ismore than 110% of the specified minimum cementcontent, the contractor shall have discreton to eitherre-design the mix or bear the costofextracementConcreteofM25gradewithminimum cement contentof 330 kg /cumOne CubicMetreConcrete of M30 grade with minimum cement contentof 350 kg /cumOne CubicMetreConcrete of M35 grade with minimum cement contentof370kg/cumOneCubicMetreConcreteofM40grade with minimum cement contentof 390 kg /cumOne CubicMetreConcrete of M50 198 Concrete of M30 grade with minimum cement contentof 350 kg 199 Applying stamping finsh of the top surface of freshlylaid plain / reinforced cement concrete of specifedgrade in portco, side walks, drive ways, pool decks andopen yard as per directon of the Engineer-in-Charge.* The concrete shall be placed and screened to thefnished grade and •oated to the uniform surface byusing standard fnishing techniques. approved colorhardener @2.7 kg/sqm shall be applied evenly to thesurface of the fresh concrete by the dry shake methodby sprinkling in twoor more shakes foated aer eachshake and trowel only after final coating. The approved released agent @ 0.113 Kg/Sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the fexiblepolyurethene stamp moulds of approved design and inrequired sizes to achieve fnal stamping pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufcient size and weight to leave properstamp marks and the process repeated for the remaining concrete surface till the whole surface to bestamped is completed within the time while the concrete is in plastic stage of setting.After stamping, the curing shall be done as permanufacturers specifcatons. After inital curing theimprinted joints shall be grouted using cement slurrymixed with color hardener as per the requirement. Thesurface shall be sealed by applying acrylic based sealernot less than 0.167 litre/Sqm on fnished surf The constructon joints shall be provided by grovecutting of size 4 mm x 20 mm in panel size 3 m x 3 m orlesser as per the site conditons and flling the samewith 10 mm baker rod and providing & laying (PU)Polyurethane based joint sealer of approved make asper manufacturer’s specifcatons and fnished byapplying polyurethene resin based topprotectve clearcoat of minimum 80 micron applied with rollers onproperly cured and dry clean surface. (The cost ofconcrete for flooring is not included in the item, whichshall be paid for seperately).One SquareMetreSupplying and laying of Uni-Axial Woven PolysterGeogrid conforming to MORTH 3100 and IRC113, as soilreinforcement/basal reinforcement includingaccessories like te-strips, nuts & bolts and loops/lugsfor joining reinforcing elements with the facia pannels,overlaps and other protectve elements for synthetcgeo-grids and all other actvites required for reinforcedsoil walls, slopes etc complete as per designrequirements, manufacturer specifcatons and as perdirecton of engineer-in- charge.Uni Axial Woven polyster geogrid of minimum tensilestrength 40KN/m in the Longitudinal directon and 20KN/m in the Transverse directon.One SquareMetre 200 62mmthickcementconcreteflooringwithconcretehardener topping,underlayer50mmthickcementconcrete1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)andtoplayer12mmthickcementhardenerconsistingof mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 201 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 202 Supplying & Laying of Precast Saucer Drain 150 thick 300 mm wideinluding sand bed etc all complete in direction of engineer in charge 203 Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 204 Providing, laying and making kerbchannel 30cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the topsmoothetc.completeandasperdirectionofEngineer-in- 205 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and fillingwith150mmthickjamunasand,includingspreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. 206 Providing andfixing10x10x10cmGranitestoneblockhandcut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mmwidefilledwithsamemortarincludingruledpointingetc. complete as per direction of engineer-in-charge. 207 Providing and laying Polished Granite stone flooring in required design and patterns,inlinearas wellas curvilinearportionsof the building all complete as per the architectural drawings with 18mmthickstoneslabover20mm(average)thickbaseof cementmortar1:4(1cement:4coarsesand)laidandjointed with cement slurry and pointing with white cement slurry admixedwithpigmentofmatchingshadeincludingrubbing, curingandpolishingetc. all completeas specified andas directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 208 ProvidingandlayingflamedfinishGranitestoneflooringin requireddesignandpatterns,inlinearaswellascurvilinear portionsofthebuildingallcompleteasperthearchitectural drawingswith18mmthickstoneslabover20mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith cementslurry and pointing withwhite cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirectedbytheEngineer-in-Charge:Flamedfinishgranite stoneslabJetBlack,CherryRed,EliteBrown,CatEyeor equivalent 209 Painting runway/taxi track/apron marking with adequatenos of coats to give uniform finish with road marking paint of superior makeasapprovedbytheEngineer-in-charge,i/ccleaningthe surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats) 210 Layingoldcementcocreteinterlockingpaverblocksofany design/shapelaidin requiredline,level,curvature,colourand pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocksshall be supplied by the department free of cost). 211 Layingatorneargroundleveloldkerbstonesofalltypesin positiontotherequiredline,levelandcurvature,jointedwith cement mortar 1:3 (1 cement : 3 coarse sand), including making jointswithorwithoutgrooves(thicknessofjoints,exceptat sharpcurve,shallnotbemorethan5mm),includingmaking drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shallbemeasuredforpayment).(Oldkerbstonesshallbe supplied by the department free of cost) 212 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastenersat both ends. The work shall be executed as perdrawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 213 Centeringandshutteringincludingstrutting,proppingetc.andremoval of form for 214 Walls(anythickness)includingattachedpilasters,butteresses,plinth and string courses etc. 215 Providing&fixingofcementconcreteBollardsM-30GradeR.C.C.150mmdiaincludinggoutinginfoundation750mm height including all necessary T&P etc all complete in directio of 216 Repairing of Existing Canopy including PPGL Sheet & necessarymember &Screw,nut, bolts,washer ,including paintingpolishingetcallcompleteindirectionofengineerin charge. 217 Boring/drillingborewellofrequireddia for casing/ strainer pipe, by suitable methodprescribedinIS:2800(partI), including collecting samples from different strata, preparing and submitting stratachart/borelog,includinghire& running charges of all equipments, tools, plants&machineriesrequiredforthe job, all complete as per direction of Engineer-in-charge,upto90metredepth below ground level. 218 300 mm dia 219 Supplying, assembling, lowering and fixinginverticalpositioninborewell, unplasticizedPVCmediumwellcasing (CM) pipe of required dia, conforming to IS:12818,includingrequiredhireand labourcharges,fittings&accessories etc.allcomplete,foralldepths,asper direction of Engineer -in-charge. 220 150 mm nominal size dia 221 Supplying, assembling, lowering and fixinginverticalpositioninborewell unplasticizedPVCmediumwellscreen (RMS) pipes with ribs, conforming to IS: 12818, includinghire & labour charges, fittings&accessoriesetc.allcomplete, for all depths, as per direction ofEngineer-in-charge. 222 150 mm nominal size dia 223 Gravelpackingintubewellconstruction inaccordancewithIS:4097,including providing gravel fine/ medium/ coarse, in requiredgrading&sizesasperactual requirement,allcompleteasper direction of Engineer-in-charge. 224 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) 225 withrequiredcapacityaircompressor, running the compressor for required timetill wellis fullydeveloped, measuringyieldofwellby“V”notch methodorany otherapprovedmethod, measuring static level & draw down etc. bystepdrawdownmethod,collecting water samples & getting tested in approvedlaboratory,i/cdisinfectionof tubewell,allcomplete,includinghire& labourchargesofaircompressor,tools & accessories etc., all as per requirement and direction of Engineer-incharge. 226 Providingandfixingsuitablesize threadedmildsteelcaporspotwelded platetothetopofborewellhousing/ casing pipe, removable as per requirement, all complete for borewell of 227 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm 228 ProvidingandfixingBailplug/Bottom plug of required dia to the bottom of pipe assemblyoftubewellasperIS:2800 (part I). 150 mm dia. 229 Supplyofsubmersiblepumpofmake KSB / Crompton / kirloskar 7.5HP with control panel, support wire etc. 230 Supply and laying of aluminium conductorPVCinsulatedarmoured served sheathed cables 1100 Volts grade ata depth of 750 mm below groundleveloveracushionof75mm. thick sand all around and protectedwithburntbricksonsidesandontop. Onsurfacethecablerunshallbe fixed onM.S.clampsetc.ofsuitablesizeor asdirectedbytheEngineer-Incharge, complete in allrespect. The armouring of the cable shallbeproperly connectedwiththe earthonductor by clamps etc.submersibble cable from pump panel to 231 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. 32 mm dia nominal bore 232 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 233 Supply of 100mm dia Johnson screen. 234 Providing and stacking of Nyctanthes arbor- tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer- 235 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 236 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of 237 Providing and stacking of Ficus panda of height 90-105cm.with10-12branchesandhealthy foliage,wellformedincementpotsofsize30 cm as per direction of the officer-in-charge.. 238 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer- 239 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 240 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 241 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size ofPoly bags & as per direction of the officer-in- 242 Providing and stacking of Asparagus sprengeri of height 15 cm to 20 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 243 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 244 Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer- 245 Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed withrivetscompleteinallrespectsincluding painting inside and outside of tree guard with: Two or more coats of synthetic enamel paint of approved quality shade over a priming coat 246 Trenching in ordinary soil up to required depth includingremovalandstackingofserviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clodsetc.andmakingthetrenchedareawith designedmounds,pathsandsittingspacesetc. toproperlevelsbyfillingwithearthorearth mixed with manure and properly watering completeworkinrequiredtopographyasperdrawing & specifications. 247 Supplyingandstackingofgoodearthatsite includingroyaltybutincludingcarriage 20 km (earthmeasusredinstackswillbereducedby 248 Supplyingandstackingatsitedumpmanure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 249 Mixing earth and manure in specified proportion or as directed. 250 Roughdressingthetrenchedgroundincluding breaking the clods. 251 Fine dressing the ground 252 Spreadingof mixedgoodearthandmanurein specifiedproportionsasaboveandinrequired thickness. 253 Providing&layingSelectionno.1grassturf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothenandlightwateringthesame,asperdirection of officer in charge 254 Preparation of mounds of various size and shape by available excavated / supplied earth in layers notexceeding20cmindepth,breakingclods, wateringofeachlayer,dressing etc.,leadupto 50meterandliftupto1.5mcompleteasper direction of Officer-in-charge. 255 Excavating,supplying andfilling oflocal earth (including royalty) by mechanical transport upto a lead of 5km alsoincluding rammingand watering of the earth in layers not exceeding 20 cm in trenches, plinth, 256 Providing & Laying reinforced cement concrete pipe NP3 for Planter 600mm height and 300 mm depth in ground including excavation, protection work, backfilling, concrete and masonary works all complete in direction of engineer in charge. 257 Fabrication , supply and installation of Stainless steel 304 grade canopy around the existing tree guard with laser cut SS -304 grade fins with satin finish and 10mm thick polycarbonate multiwall sheet on roof from sabic plastic products or equivalent complete in all respect along with it aluminum fittings . SS-304 grade tree grate with laser cut design cutout patterns for waterpenetration will be fixed at the center and 18mm thick gang saw cut mirror polished granite/wood plastic composite wooden planks will be fixed ontop of the existing masionary in a curve shape 258 Cement Concrete Planter 259 D & E .( HORTICULTURE AND EXTERNAL ELECTRICAL WORK)-HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT BILL OF QUANTITY 260 Part G (Horticulture Work) 261 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 262 Supplying and stacking of good earth at site including royalty and carriage upto 20 km lead complete (earth measured in stacks will be reduced by 20% for payment). Analysed Rate. 263 Extra For levelling and neatly dressing of disposed soil completely as per the engineer in charge DSR2023; 2.36 264 Supply and laying of bi axial extruded high modulus polypropylene geo grid conforming to MORTH specifications for base/sub base reinforcement having minimum tensile strength 40 Kn.m IN THE LONGITUDNAL AND TRANSEVERSE DIRESTION, WITH 14 Kn/ M AND 28 Kn/M AND 28 Kn/M TENSILE STRENTGH at 2% and 5 % strain respectively in the longitudnal and transverse direstion, junction eficiency not less than 95% and with 38 mmx 38 mm mesh opening psrLDA Approved 265 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).DSR Horticulture 2020; 2.25 266 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 267 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).DSR Horticulture 2020; 2.8 268 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, byspreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).DSR Horticulture 2020; 2.1 269 Rough dressing the trenched ground including breaking clods.DSR Horticulture 2020; 2.6 270 Fine dressing of the ground., DSR Horticulture 2020; 2.7 271 Providing & laying Selection no. 1 doob grass turf with earth 50mm to60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge DSR Horticulture 2020; 2.34 272 Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately): In rows 5 cm apart in both directions DSR Horticulture 2020/ 2.10.1 273 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 60 cm dia, and 60 cm deep. DSR Horticulture 2020; 2.14.4 274 Holes 45 cm dia, and 45 cm deep., DSR Horticulture 2020; 2.14.5 275 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal ofunserveiceable material’s as per direction of officer in charge (excludingcast of plant & water). DSR Horticulture 2020; 2.57 276 Trees Plant, 2.57.1 277 Shrubs Plant, 2.57.2 278 Hedge Plant, 2.57.3 279 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge., DSR Horticulture 2020; 6.7 280 Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge., DSR Horticulture 2020; 5.3 281 Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge., DSR Horticulture 2020; 8.30 282 Providing and stacking Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. DSR Horticulture 2020; 9.8 283 Providing and stacking of Belamcanda chinensis of height 45-60 cm. branched in earthen pots of size 20 cm as per direction of the officer-in-charge. (Lepord lily), PSR LALBATTI 284 Providing and Displaying of Spathiphyllum (peace lily), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cmof Earthen pot/plastic pot as per direction of officer-in-charge. DSR Horticulture 2020; 3.90 285 Providing and stacking of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliagein Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge., DSR Horticulture 2020; 6.25 286 Shrubs/TREE Plant 287 Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.(DAR 2020 Hort - 8.32) based 288 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12branches and healthy foliage, well formed in cement pots of size 30 cm asper direction of the officer-in-charge. (DAR 2020 Hort - 8.28) based 289 Trees Plant 290 Providing and stacking of Jacaranda mimosifolia of height 10-12 feetin big poly bags of size 18 as per direction of the officer-in-charge.PSR 291 Providing and stacking of Butea frondosa (Flame of Forest) healthy and multi branches of height 4-6 feet in big poly bags of size 18 as per direction of the officer-in-charge.PSR 292 Providing and stacking of Lagerstroemia Flaush (jarool) healthy and multi branches of ht.10-12 feet in Earthen pots of size 12 as per direction of the officer-in-charge. PSR 293 Providing and stacking of Tabebiua (Dolne smith) healthy and multi branches of ht.12-14 feet in Earthen pots of size 18 as per direction of the officer-in-charge. PSR 294 Providing and stacking of Terminalia Mentali healthy and multi branches of height 10-12. in big polybags of size 18 as per direction of the officer-in-charge. PSR 295 Providing and stacking of Plumeria alba healthy and multi branches of height 10-12 feet in big poly bags of size 18 as per direction of the officer-in-charge.PSR 296 Providing and stacking Nicodia of height6-8 feet with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.PSR 297 Providing and stacking Cassia Gluca of height 8-10 feetwith bushy healthy plant in 14 bags & as per direction of the officer-in-charge. PSR 298 Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.PSR 299 Supply and installation ofBamboo of Height 10-12 feet. In all work complete. Market RatePSR 300 (Irrigation) 301 Trenching and Back Filling. Sanctioned Rate. 302 Supply, Installation, laying & commissioning of 90 mm outer dia 6Kg/cm2 HDPE pipe. 33.01 (Jal Nigam Varanasi SOR) 303 Supply, Installation, laying & commissioning of 63 mm outer dia 6Kg/cm2 HDPE pipe. 33.01 (Jal Nigam Varanasi SOR) 304 Supply, Installation, laying & commissioning of HDPE Flange with tail piece, packing & nut bolt complete in all respect. Sanctioned rate 305 Supply, Installation, laying & commissioning Of reducer 90 mm to 63 mm outer dia 6Kg/cm2 HDPE pipe. Sanctioned rate 306 Supply, Installation, laying & commissioning Of ELBOW JOINT 90 DEGREE FOR 90 mm HDPE pipe. Sanctioned rate 307 Supply, Installation, laying & commissioning Of ELBOW JOINT 90 DEGREE FOR 63 mm HDPE pipe. Sanctioned rate 308 Supply, Installation, laying & commissioning Of TEE JOINT90 DEGREE FOR 90 mm HDPE pipe. Sanctioned rate 309 Supply, Installation, laying & commissioning Of TEE JOINT90 DEGREE FOR 63 mm HDPE pipe. Sanctioned rate 310 Supply, Installation, laying & commissioning Offor 63 mm TAIL PIECES. Market Rate 311 Supply, Installation, laying & commissioning of for 90 mm TAIL PIECES HDPE PIPES. Market Rate 312 Supply, Installation, laying & commissioning Of PRESSURE Gauge 2.5 size (Gyceryne). Market Rate 313 3 disc filter. Market Rate 314 2 disc filter. Market Rate 315 Thermos Temperature Controller wuth switch and socket .2 mm cable. Market Rate 316 Butt velding electric heating plate. Market Rate 317 3 CIbutterfly valve. Market Rate 318 2 CIbutterfly valve. Market Rate 319 SPRINKLERS 320 Supply, Installation, laying & commissioning of Service Saddle 3 inch x 1.25 inch. Sanctioned rate with bush 321 Supply, Installation, laying & commissioning of Service Saddle 2 inch x 1.25 inch. Sanctioned rate with bush 322 Supply, Installation, laying & commissioning of Swing Joint for 10 - 12 meter range 360 degree popup. Market Rate 323 Supply, Installation, laying & commissioning of Swing Joint for 3 - 4 meter range 360 degree popup. Market Rate 324 Supply, Installation, laying & commissioning of 25 mm outer dia 6Kg/cm2 CPVC pipe. Market Rate 325 Supply, Installation, laying & commissioning Of Ball Valve for 25 mm pipes. Market Rate 326 Supply, Installation & commissioning of pop sprinkler plastic make material with 3 - 4 meter range 360 degreesMR 327 Supply, Installation & commissioning of pop sprinkler plastic make material with 10- 12meter range 360 degrees. Market Rate 328 Engagement of Plumber for required work etc all complete as per direction of Engineer in charge. PWD SOR 2020-21/Labour Rates Chapter.Rs. 420.00+10%CP 329 Engagement of Labour for required work etc all complete as per direction of Engineer in charge. PWD SOR 2020-21/Labour Rates Chapter.Rs. 335.00+10%CP 330 4 - BORING 331 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate 332 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.3.3 333 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.10.3 334 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 335 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for bore well of: 200 mm dia. DAR No. 23.13.3 336 Providing & Fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS 2800 part - 1 including necessary bolts & nuts of required size complete. 200 mm clamp. DAR No. 23.14.3 337 Supply and fixing of pump set & composite electric panel for submersible kirloskar/ sons/ crompton openwell pumpset greeves make three phases 380-440 v 50 cycles supply with fountain bolts and 3 core 2.5 mm flat PVC flexible copper conductor double insulated submersible cable and 4 core 1.5 mm form fountain pool to fountain electric panel etc fountain pool to fountain electric panel etc. complete with internal wiring lighting system. 338 7.5 HP pump 339 Electric Panel Box 340 Supply and fixing of 3 HP single phase open well submersible pump set of 50 mm x 50 mm pipe size complete with all material, labour T&P etc all as per direction of Engineer in charge. (make kirloskar/ crompton/ KSB 341 Supply and fixing of 2.5 sqmm 3 core PVC insulated PVC shethed flate submersible cable pump with bare bunched copper conductor for submersible pump motor with 1100 volt grade ISI marked all complete as per direction of Engineer in charge.Sanctioned Rate 342 Arrangement of Plumber for 1 year maintenance. PWD SOR 2020-21 343 Horticulture Maintenance 24 months 344 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide will be provided by the Department & lawn mover and brush cutter with fuel , other T & P material/articles shall be provided by the contractor.) Play grounds / Public parks Per Sqm (as per yard stick 1Mali =2.00Acre).DSR (Hort) 2020/2.40.5 345 Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/ edge bed watering, manureing & apply insecticides & fungicides etc. (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.DSR20202.2.36 346 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 05 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment). DSR 2020 horti - 2.25 347 Supplying and stacking of good earth at site including royalty and carriage upto 15 km complete (earth measured in stacks will be reduced by 20% for payment). Analysed Rate. 348 Supply & stacking Urea 40% Nitrogen @160 kg per acre (as per yard stick of CPWD LDA SOR 2018-19/11.1 349 Supply & stacking DAP 50 kg per acre/year. LDA SOR 2018-19/11.2 350 Supply & Stacking Bone Meal/ Oil Cake(LDA SOR Horti 2018-19/11.3) 50 kg per acre/Year 351 Removal of garden waste by TATA 407 or equivalent including loading and unloading and carriage upto 1 km lead, complete disposal upto designated place as per direction of Officer in charge. DSR Horticulture 2020/2.60 based (Analysis Rate attached) 352 Part H (Electrical) 353 PART (X) 354 FOUNTAIN 355 SITC of Spray comprises of a Calyx Aerating in center flanked with Foam Jets on 4 corners of waterbody.Manifold/Pipework are made from Galvanised steel, B-class, make Jindal, ISI Mark with necessary accessories like flanges, sockets, stands etc. made of steel- galvanized. High quality rubber gaskets, nuts & bolts along with gunmetal control valves to adjust flow pressure.Proper completion of workAs per direction of E/IcFOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 356 SITC of In Calyx Aerating Spray, water is sprayed in an inverted cone pattern withasmallcenterjet.Calyxnozzlemadeofaluminiumalloy– epoxycoated/StainlessSteel,centerjetnozzlemadeofbrass– chromeplated.Approx.heightofwatereffects:Calyx–1.25m heightX4.5mdia,CenterJet–3mheight. Proper completion of workAs per direction of E/Ic,FOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 357 SITC of Foam jet nozzle, on ball joint, of1.25” orifice size. Nozzle made ofBrass- Chrome plated. Approx. height of water effects: 1.2m. Proper completion of workAs per direction of E/Ic, FOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 358 Supply,Installation,TestingandCommissioningofLuminaries comprise of 12V LED lights (RGB). Complete light body made of Stainless steel 304 grade, total 27watt power leds. Toughened glass with seal.Stainless steel 304 grade cable gland. All external nuts and bolts are of Stainless steel 304 grade. Adjustable mounting bracket is made of Stainless steel 304 grade. IP 68 compliant. All in pool connections shall be fully waterproof. Make of Luminaries As per direction of E/Ic,FOR A 6 METER DIA WATERBODYPSR 359 SITCofMonoblocktypesubmersiblepumpset whit stainer/ filter ofFollowing Capacity(Threephase,50Hz,415-380VAC)propercompletion ofworkasperdirectionofE/Ic. Kirloskar/Crompton Greaves/KSB/Texmo. Suction filter for pump: Filter body & filter mesh made from AISI 304 standard stainless steel. As per direction of E/Ic 360 3 HP PSR 361 SITC of 1.1 kV grade double insulated copper flexible cable 2.5 sq.mm x 3 core for pumps,As per direction of E/IcPSR 362 SITC of 1.1 kV grade double insulated copper flexible cable 1.5 sq.mm x 4 core for lights, As per direction of E/Ic PSR 363 PSR Supply, Installation, Testing and commissioning of specialised Outdoor type Electric panel for fountain which include control arrangement for fountain, pumpset andRGB Sequencing lighting comprises of :1. Contactor 25 Amp- 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)2. DOL Starter - 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)3. Single Phase Preventer- 01 Nos (Make: Bentex/ Selec/ GIC or equivalent)4. Incomer Main Switch 20 Amp- 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)5. Overload Relay 6-12 Amp- 01 Nos (Make: L&T/ Schneider/ ABB/ BCH or equivalent)6. Fuse for motor 32 Amp- 03 Nos (Make: GE/ L&T or equivalent)7. MCB for Lights 6 Amp -01 Nos (Plaza/ Anchor/ ABB/ Havells/ Legrand or equivalent)8. Push Button On/ Off switches (Red/ Green)- 02 Nos. 9. Overload Indicator - 01 Nos (Make: Eaton/ Siemen or equivalent)10. Single Phase Indicator- 01 Nos (Make: Eaton/ Siemen or equivalent)11. 3 Phase indicator RGB- 01 Nos (Make: Eaton/ Siemen or equivalent)12.Voltmeter- 01 Nos. (Make: Motwane, Innova, Fluke or equivalent)13. Ampere Meter- 01 Nos (Make: Motwane, Innova, Fluke or equivalent)14. SMPS/ Transformer for lights- 01 Nos (Make: Meanwell/ Pheonix/ Omron or equivalent)15. RGB Lights controller- 01 Nos. (Make: Wet Design/Fontana/A.M. Irrigation System/Bharat engineers)16. Internal Wiringsteel sheet 16 gauge paint finish enclosure with hinged front door with provision for incoming & outgoing cable entry. Outgoing ampere 10, size of panel - 3ft X 2ft X 1ft depth.As per direction of E/Ic PSR (36/G20/CE/23) 364 Supply of 4000mm Extruded Square aluminum pole (grade 6063) Sq. 150 x 3mm thickness with IP68 Connector.Bespoke laser cutting design of length 1400mm with 50W In-Built LED with controlled downward light emission options (customized) with SS fasteners, Pre treated epdm black gaskets. Die-cast aluminum mounting plate Sq.250 x 12mm thick with 4 elongated holes 38 x 19 to suit M16 bolts at PCD 180 with pure polyester powder coating. Fixed with Hot dip galvanized foundation bolt. Mechanical resistance should be minimum IK06. The Pole should be undergone pure polyester powder coating process & Acid treatment to ensure high corrosion resistance. On the top of the pole there will be built-in Spot Lights of 2 x 18W LED are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Inbuilt Surge protection 6KV. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Colour Temperature LED 3000K, 230-240Vac, CRI >80, MacAdam step 3. The driver should be inbuilt in the pole itself and maintenance can be done from the junction box itself. PDC aluminum service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable,6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Any other internal cables and connections shall not be covered in the scope of supply. The manufacturer should have Inhouse NABL accredited lab to check and provide correct photometry of the product. The make should be as per K-Lite Verbena Spot KL-4583/Wipro/Ligman 365 Supply and fixing of 3500mmsteel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . POLES BPTH SIDE OF THE ROADS AT 10 METER CC DISTANCE. PSR - BEGUM HAZRAT MAHAL PARK 366 Supply and fixing of OVER 600mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore, K LITEor equivalent repuateted make Quotation rates 367 S/E of G.I. wire on 8 to 4 SWG on pole/service bracket including binding etc. complete in all respects SI.No. 628/18. 368 S/W of submain with two Nos. of 2.5 Sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material Labour and T&P required for proper completion of the work as directed at site by E/I. SI. No. 289/18. 369 S/Fof40ATPNofAutomaticstreetlightcubiclecontrolpanelpaintedwithanti corrosivealkaliandacidproofpaintconsistingoftimeswitchTSO100serieswith contractors,HRCfuses,isolatingswitchmeteringinstrument& instrumentbox with CTs etc, in case of TPN, complete in all respect as per direction of Engineer-in-charge. SI. No. 807/18 e(ii). 370 S/L of following cable Al conductor P.V.C. insulated armoured served sheathed cable 1100V grade at a depth of 750mm. Below ground level over a cushion of 75mm with DWC Pipeapproved makeUPPPCL as per direction of E/I. complete in all respects. 501/2018. Approved Makes:- Gloster/ Polycab/ KEI/ SCI/ Havells PWD SOR 501 371 10 sq. mm 4 core 372 (a) 35 Sq.mm 3.5Core 373 (b) 16 Sq.mm 4 Core 374 (c) 70 Sq.mm 3.5 core 375 S/F of following size palm or pin type copper tin plated cable socket (Lug) to the cable leadinsulatingwithtapeandmakingconnectionscompleteinallrespectsasper direction of E/I.SI.No.504/SOR-18. 376 10 sq. mm 4 core 377 (a) 25 sq.mm. 378 (b) 50 sq.mm 379 (c) 16 sq.mm 380 S/B of earth rod 20mm dia into 2.5mtr long including G.I. wire 7/16 SWG to connect earth rod to earth clamp on pole 3.00 mtr long steel conduit to carry earth wire along the pole. A.R. Bond No.87/CE/EE(E/M)2021, Dated 09-11-2021 381 S/Fof6Ampto32Amp.SPMCB(10KA)Ccurvecompleteinallrespectasper direction of Engineer-in-charge. SI No. 1002/18. CAT-A. 382 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountendon non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. ( Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TNP-2 Nos. Cat. B. Cubicle TypePWD SI No : 802 (a) 383 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PWD SI No :725 (A) 384 Supply and Laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. DSR E&M 2022/14.161 385 Supply, Installation, testing & commissioning of Servo Stabilizerwith Isolation transformer 100KVA,3-phase servo voltage stabilizer with isolation transformer , oil cooled, Input 300-470 VAC, 4 Wire, 50 Hz, output: 400+/-1% with oil,suitable for UNBALANCED LOAD with automatic operation (outdoor type-IP 64).The stabilizer shall comply with the following requirement:: Regulation : +/- 10 %.: Over load & Short circuit protection.: Protection cut-off against Over/Under Voltage.: Single phase protection.: 3 nos. phase indication lamps. 386 PLINTH AREA RATES CPWD 2023, Supply installation , testing and commissioning of IP based CCTV system for building security comprising of PTZ/FIXED CAMERA, CABLING , RECORDING , DISPLAY SYSTEM HARDWARE SOFTWARE SUPPORT,FOR EXTERNAL SURVILLANCE 6.10.2 , FOR PLAZA AREA ONLY 387 Operation and maintenance for 1 years 388 PART (Y) 389 LFkkfir dh x;h ykbZVksa ds vuqj{k.k ,oa lapkyu dk dk;ZA 390 Providing of Trained Electricion With Tool Kit (As per PWD SOR/2020-202. For 18 months after DLP 391 Providing ofHelper Technicion (As per PWD SOR/2020-2021.For 18 months after DLP 392 PART-Z 393 H.T./L.T. work 394 S/Fofdoublepolestructurewith2nosS.T.poleforS/S 410SP-55 11 Mtr. longin1:3:6CC foundation 1/6 of pole length below G.I. and 30cm above G.I. 20cm thick around the pole with 2 nos. channel 125mmx75 mm one No. Chennel cross arm of 75mmX 40mm 2 No. 50X50X6mm sngle iron bracings with necessary nut bolts & packing pieces complete with painting as per direction of E/I.(PSR Bond No. 490/CE/2024) 395 S/F of 11 KV Pin insulator with G.I. Bolt /spindle nut etc. complete in all respects. (PSR Bond No. 490/CE/2024) 396 S/Fof11KVDiscinsulatorincludinggunfittingoncrossarm/clampsfixedonpole complete in all respects. (PSR Bond No. 490/CE/2024) 397 S/E of over head line with A.C.S.R. conductor on pole/service bracket including binding etc. complete in all respects. S.I.No-627/18. Racoon/Dog(PSR Bond No. 490/CE/2024) 398 S/F of M.S. Channel 75mmX40mm Vshape crossd arm for two No. pin insulator proper completion of work. (PSR Bond No. 490/CE/2024) 399 S/E of 11 K.V L.A. set of 3 wire. suitable for mounting on steel support complete in all respect as perdirection of E/I.(PSR Bond No. 490/CE/2024) 400 S/Eof11K.V.T.P.M.O.switchonpoleincludinghandlerodetc.completeinall respects as per direction of E/Ich.(PSR Bond No. 490/CE/2024) 401 S/E of 11 K.V. D.O. fuse set on pole complete in all respect as per direction of E/I.(PSR Bond No. 490/CE/2024) 402 Supply and laying of70 Sqmm 3 core 11 KV standered aluminium conductor XLPE(Cross linked polyethylene)insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connectedwith earth conductor by clamps etc. PWD SOR No : 506 (d) (PSR Bond No. 490/CE/2024) 403 S/F of 70 Sq.mm size 3 core XLPE 11 KV outdoor type jointing kitproper completion of work as per direction of E/I A.R. Make: Raycheme, Mahindra. (PSR Bond No. 490/CE/2024) 404 S/F of level 2 following capacity 11/0.433 K.V. Al’ wound conventional 50Hz 3 phase oil immersed naturally cooled distribution T/F confirming and with amendments there of, havinglosses as per BEE standered with all standard fittings, including first filling of oil complete in all respects, of make UPPCL/KESCO Approved (PSR Bond No. 490/CE/2024)(a) 63 KVA (A.R.) 405 Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra)Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.S.I.No-726 B/18. 406 S/Lof25mmx3mmGIstripfromearthelectrodedirectlyinthegroundasrequired complete in all respect Item No 716 SOR-2018 407 Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion ofwork. PWD SI No : 1142 408 S/L of followingsize G.I.B classpipe ata depthof 750mmbelow groundlevel as cable carrier as direction of E/Inch. (PSR Bond - 490/CE/2024)(a) 80 mm dia
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Uttar Pradesh View Result →
30.
Public Administrative Department #9476162 Technical Bid
Tender For Water filling work in Butler lake from STP (Dalibag) to Butler lake - Providing, laying, jointing and testing S&S Centrifugally Cast Ductile Iron double chamber Class K-9pressure pipes conforming to IS : 8329:2000 with restrained joints (bolt less), all complete. 2 350 mm dia 3 Excavation for sewer pipe line in ordinary/kankar soil in trenches with lift upto 1.5m and lead upto 50m refilling of excavated earth into trenches and removal and disposal of surplus earth with in a distance of 50m from centre of the trenches. 4 In ordinary soil (0.00-1.50) 5 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 6 350 mm dia 7 Carting of sluice valve of following sizes to site of work, lowering in already prepared trenches and fixing them in position, making flange joints including supply of all materials, such as bolts, nuts, rubber insertion, white lead, testing etc. complete. 8 350 mm dia 9 Supply of all materials, labour, T&P etc. and construct sluice valve chamber as per type design. 10 Masonary type 11 Supply of following size double ball CI air valves with gun metal sheet. 12 50 mm dia 13 Cartage of following size double ball CI air valves with gun metal sheet. 14 50 mm dia 15 Supply of all materials, labour, T&P etc. and construct air valve chamber as per type design. 16 Dismantling of roads for laying sewers including sorting out and stacking of serviciable materials, and diposal of unserviciable materials upto a distance of 60m and its reinstatement after filling and proper compaction of trenches. 17 PWD Bitumen Road 18 Reinstatement of Road after Laying of pipe in Internal Bitumen Road including sand filling, GBM 125mm thick compacted layer, WBM 150mm thick, priming coat, bitumen emulsion over priming coat, BM 40mm thick and 25mm thick SDBC etc. (Detailed analysis attached) for PWD roads. (5320/1.18= 4508.47) 19 Construction of MPS 20 Barricading of both sideof trenches with the help of Balli, Bamboo etc. in three rows upto 1m high post should befixedat3metc.includingall labour,materialsetc.completeas perdirectionofEnginnerincharge measurementofbarricadingwillbe only one side. 21 ExcavationinfoundationinOridinary soilincludingliftasspecified and lead upto 50 m filling water and ramming of excavated earth, all T&P, labour, materials etc. complete for the proper completion of the work and as per direction of engineer in charge. 22 0.00 - 1.50 M 23 1.50 - 3.00 M 24 3.00 - 4.50 M 25 4.50 - 6.00 M 26 6.00 - 7.50 M 27 7.50 - 9.00 M 28 9.00 - 10.50 M 29 Dry stone ballast 40 - 63mm size laid and compacted with sand in proportion of 1:4 complete. 30 9.00 - 10.50 M 31 Cementconcretewith20mmgauge approvedstoneballast,Coarsesandand cement in proportion 4:2:1 including supply of all materials, labour T&P etc. required for proper completion of workbelow GL 32 For Sump Well 33 9.00 - 10.50 M 34 RCCworkwithcement,coarsesandand 20mm gauge stone ballast in proportion of 1:1½:3 (excluding cost of reinforcement and itsbending)butincludingitsfixingand bindingwith0.50mmthickbindingwire(to besuppliedbythecontractor) and necessary shuttering, supply of all materials, labourT&Petc.requiredforproper completion of work. 35 FOR SUMP RAFT 36 9.00 - 10.50 M 37 RCCworkwithcement,coarsesandand 20mm gauge stone ballast in proportion of 1:1½:3 (excluding cost of reinforcement and itsbending)butincludingitsfixingand bindingwith0.50mmthickbindingwire(to besuppliedbythecontractor) and necessary shuttering, supply of all materials, labourT&Petc.requiredforproper completion of work. 38 RCC WALL 39 Above GL (0.00 - 3.00 m) 40 Wall Thickness= 0.40 M 41 0.00 - 1.50 M (3.14 x 6.8 x 0.4)x1.5 42 1.50 - 3.00 M (3.14 x 6.8x0.40)x1.5 43 Wall Thickness= 0.50 M 44 0.00 - 1.50 M (3.14 x 6.5x0.50)x1.5 45 1.50 - 3.00 M (3.14 x 6.5x0.50)x1.5 46 Wall Thickness= 0.60 M 47 6.00 - 7.50 M (3.14 x 7.2x0.60)x1.5 48 7.50 - 9.00 M (3.14 x 7.2x0.60)x1.5 49 9.00 - 10.50 M (3.14 x 7.2x0.60)x1.5 50 Same as above but in T-Beam slab and canti lever chajja in proportion 1:1.5:3 51 Centering and shuttering including strutting, propping etc. and removal of form for Extraforshuttering incircular work(20%ofrespective centering and shuttering items) 52 Mild steel or iron work in plain work suchasinRCC workwroughtto required shape as necessary including bending for proper completionoftheworkincluding supply of the steel and wastage. 53 Supplyandfixingof MS Railing over cantilever and lifting platform made of 50x50x6mm MS angle vertical posts 1 M high fixed at 1.20 M interval and 3 rows of MS flat 40 x 5mm welded to the vertical posts including fixing in slab and painting etc. complete. 54 Supplyandfixingofsteelladder including supply of all materials, labourandT&Petc.completefor proper completion of work. 55 Disposal of surplus earth from the site upto a distance of 10 Kms. including all labour, loading unloading truck charges including all materials,T&P etc. complete for proper completion of work. 56 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 57 Apex painting over exposed part of sump well with 2 coats of approved apex paint over priming coat complete 58 Provision for MS jali to cover the chamber 59 PUMP HOUSE 60 Firstclassbrickworkin1:6cement& Local sand mortar in foundation and plinth includingsupplyofallmaterials,labour, T&Petc.required for the proper completion of the work. 61 RCC work with cement, coarse sand and20mmgaugestoneballastin proportion of 1:1½:3 (excluding cost ofreinforcementanditsbending) butincludingitsfixingandbinding with 0.50mm thick binding wire (to be supplied by the contractor) and necessaryshuttering,supplyofall materials, labour T&P etc. required for proper completion of work. 62 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform, WalLs, etc. 63 Mild steel or iron work in plain work such as in RCC workwroughttorequiredshapeas necessary including bending for proper completion of the work including supply of the steel and wastage. 64 12 mm thick plaster with cement and coarse sand mortar I:4 over brick work minimumthicknessnottobelessthan10 mm including supply of allmaterial, labour T &Petc. requiredforpropercompletionof work. 65 Ornamentalplasteronoutsideof PH =ai+aii-aiv-av 66 FLOORING 67 Kota Stone flooring in PH 68 40mm thick 1:2:4 PCC floor with cement, coarse sand and 20mm gauge stone ballast without base concrete. 69 Supply and fixing of I.S.M.B. 250 and M.S. grill, door including one coat of redoxideandtwocoatsofblack Japanpaintincludingfabrication, supply and fixing of chequered plates. 70 Provisionforwaterproofing compound. 71 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 72 Supplyofallmaterials,labour,T&P etc. for fabrication of M.S. flat grills in windows. 73 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. 74 Door&Window 75 Supply of rubber matting. 76 Supply and fixing of exhaust fan. 77 Apex painting over exposed part of sump well with 2 coats of approved apex paint over priming coat complete 78 Enamel painting in door & windows including labour and material costs. 79 Provision for soil testing work. 80 Provision of lightening conductor 81 M.S. Gratings 82 Misc. and unforeseen. 83 Cost of Pumping Plant of MPS 84 PumpSet: 85 Supply of submersible sewage bottom suction non clog Pumpsets having Speed 960 RPM & Bearing insulation should be compatible for VFD operation and handling raw sewage of Sp. Gr. 1.05 with Pumpset accessories such as duck foot bend,Pedestal auto coupling with Guide rail system of SS 316 submersible pump sets comprises of guide pipe, bracket, upper guide rail holder and lifting chain with D-Sackle etc complete and Material of Construction shall be-:Casing- 2% Ni-CI with hardnessranges 220- 275 BHN approx, Impeller - Super duplex steel , Hardness 220-260 BHN.,Shaft- SS 410 with ceremic coating, hardness 700 BHN at the minimum.,Bearing- anti frictional L-10 with 60000 hours life.Operational Voltage 380±10% 3 phase AC Supply. The duties of pumpsets as follows -: (NOTE- Pump Discharge, Head & motor HP are tentative and may vary as per actual site condition at the time of execution.) 86 Duty of Each Pumpset working as module of (1W+1S)-: Discharge- 116 LPS, Head- 24 m and electric motor of 75 HP or suitable rating 87 VFD Starter Control Panel with push button suitable for operation on 415V ±6% ,3 phase, 50 Hz,AC supply with all necessary switchgears, controlgears and protections along with automatic power factor correction feature and also compatible to PLC based SCADA Automation operation and suitable to followings motor. 88 75 HP or suitable to above Pumpset. 89 Sluice valve 90 Manually Operated CIDF Rising spindle type Sluice valve with integral starter & gearbox PN 1.0 having body door, dome gland in graded cast iron, four faces and spindle nut of Bronze LTB 2 Spindle of St. Steel 410 and specifications should be as per relevant I.S. of following sizes. 91 250 mm dia 92 350 mm dia for common header 93 Cast iron pipes & specials. 94 Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection. 95 Reflex Valve 96 CIDF double flanged single/multi door swing check valves PN 1.0having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and specifications should be as per relevant I.S.&shall be of following sizes: 97 250 mm dia 98 350 mm dia for common header 99 CI Dismantling joints 100 250 mm dia 101 350 mm dia for common header 102 C.I. SLUICE GATES: 103 Manually operated Open Channel sluice Gate in CI with gearbox, single facesrising spindle type generally conforrming to releavant IS , havingframe & door fitted with St. Steel faces M.S extension rod with coupling andGuide brackets suitable to a required distance size suitable for 600x600 mm. cutout size at the inlet & outlet of screen chamberas per site requirement. (Note : Size is tentative and may vary as per actual site conditions.) 104 Manually operated Thimble Mounted CI Sluice Gates of rising spindle type with gearbox,suitable for 450mm. dia incoming seweras per site requirement.(Note : Size is tentative and may vary as per actual site conditions.) 105 COARSE SCREEN 106 ManualS.S.316 bar coarse screen 1.00 x 1.0 meter size having spacing 20 mm , thickness 10 mm as per site requirement.(Note : Size is tentative and may vary as per actual site conditions.) UPTO 8.5 MLD 107 E.O.T. crane of 3 Tonne capacity along with gantry girders, chain pulley block and geared trolley suitable for 10 m span 15m clear lift complete in all respect for pump house. 108 Pressure Guage 109 150 mm dia 0-6 Kg/ sq cm. digital pressure guage with S.S. tubing stop cock and necessary fittings. 110 L.T. Panel BoardConforming to IEC-60439 111 L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity. Aluminium Bus Bar size of 50x20 mm. and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 112 01 No. incoming feeder from 01 Nos. from LT Power Supply coming from Main LT PCC Panel of MPS with following details:- (PCC- 3587471+50000=3637471) 113 01 nos.630 A MCCB 50 KA, for Incomer of Main LT supply coming from common LT PCC Panel for MPS with indication lamp mechanical on/off indicator. 114 01 nos.400A ampsor suitable rating,25 KA M.C.C.B.for D.G.Set incomer with indication lamp mechanical on/off indicator. 115 One set of current transformer of suitable ratio 116 One No. CT operated ammeter suitable ampere rating with ammeter 117 One No. Voltmeter 0-500 V with voltmeter 118 One No power factor meter 0.5 lag/ 1-0.5 lead 119 One No Surge arrestor Relay & One no. UV/OV Relay 120 One No frequency meter. 121 Total outgoing feeder as follows- 122 03 nos. 200A MCCB of 25KA capacity with indication lamp mechanical on/off indicator for pumps. 123 Ammeter with selector switch. 124 Single phasing preventer. 125 Sets of timer and relays for overload and underload. 126 04 Nos. level indicators with control cable from L.T. Panel to pumping plant for automatic level operation of pumping plants including moisture sensor and other protection for 04 Nospumping plants. 127 One Nos. 63 Amps. MCCB for lighting. 128 One Nos. 63 Amps. MCCB asMisc. load 129 02 Nos. 32 Amps. MCCB for spare. 130 OneNos. 32 Amps. MCCB with auto operation. 131 CE/UL Certified Electromagnetic type Full-Bore Flowmeter 350 mm diashall be suitable for bi directional flow measurement.This shall be having protection category of the sensor shall be IP68 and protection category for the transmitter shall be IP- 65. Accuracy shall beof +/- 5% of measured value without being affected by variation in the line pressure. Equipment should be complete with converter, transmitting device and should be fully programmable with digital flow indicator & integrator etc. The sensor housing and junction box should be of SS 316. complete with control cable and display with application in Sewage . 132 Power and control cables 133 1100 V grade, 3.5 core 25mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to juction box.(1x4x50 mtr.) 134 1100 V grade, 3.5C x 120mm2 , XLPE insulated Aluminium Armoured conductor cable from Common LT distribution panel to MPS LT Panel. 135 Al.junction box in SS304, IP65 with instruments for pumps with Busbar. 136 1100 V grade, 3.5C x 240mm2 , XLPE insulated Aluminium Armoured conductor cable from Common LT distribution panel to MPS LT Panel. 137 EARTHING 138 Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) for Pumps,LT Panel & other Panel. Size of earthing plate 600mm x 600mm x6 mmwith salt and coal. 139 Lighting system: 140 Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. 141 S/F of 72 watt LED with lumen reflector. 142 Feeder pillar for lighting 143 Supply and laying of 4x16mm2 Al. armoured cable. 144 Supply and fixing of 280x170x130 mm.size sintex junction boxes on poles. 145 Supply and laying of unarmoured Al. cable 6 mm2 4-core Flat PVC insulated for connection of LED to junction boxes. 146 Internal electrification with fixtures. 147 S/F 1200 mm ceilingFan for LT Room 148 S/F of exhaust Fan for LT Room.& Other rooms. 149 Earthing of street light pole (SOR-41) 150 Painting of street light (P5-634) 151 Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) 152 12 mm thick rubber mating for safe working on. 153 Tools 154 Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 155 Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well 156 Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6x 12, make- Taparia)Plier (250mm, make-Taparia) 157 Chain wrench (12x18, make Taparia) Pipe wrench (1200mm, make Taparia) 158 Installation of above equipments with all required materials & fittings with labour. 159 Testing of all above E/M Items at O.E.M. Place. 160 Commissioning of all above E/M Items 161 Chequered plate of required size so as to cover all trenches. 162 Power Distribution Transformer : 163 Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 160 KVA double wound with copperwinding, Level-2 or 3, vector group dyn 11, ONAN with Offload tap changer operated for voltage variation + 5.0 % to - 10% in step of 2.5% with standard fitting & accessories complete in all respect. 164 Supply and laying of 1100 voltage grade ,1x3.5Cx 240 mm2 Aluminium conductor, XLPE armoured cable from both Transformers to LT Panel. 165 Installation, testing and Commissioning of Transformers with Double Earthing works complete as per IS & IER along with construction of suitable PCC Foundation / Platform with all labour & materials complete in all respect. 166 H.T. Switch Gear Panel : 167 Supply of 12 KV,H.T. V.C.B. Panel with 01 incoming & 02 out going ,800 Amp. (25 KA) Rating have followings- 168 Incommer Feeder- 01 No. 169 3 O/C + 1 E/F IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. (1750000+50000=1800000) 170 Outgoing Feeder- 02 Nos. 171 outgoing feeder control panel equiped withtriple pole 3 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. 172 DC Supply 173 SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. 174 Erection of All above equipments and fencing with iron mesh (if required)etc. complete in all respect. 175 Commissioning of All above equipments etc. complete in all respect.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
31.
Public Administrative Department #9476141 Price Bid
Tender For Upgradation, Interior/Furnishing Work Of Commissioner Lucknow Division Lucknow Office - TOILET SANITARY FITTING WORK 2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes.DSR -18.8.2 3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes.DSR -18.8.3 4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes.DSR - 18.8.4 5 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mmDSR - 17.10.1.1 6 Providing & Placing of Looking Mirror pasted on wall with the help of silicon having edges beveled, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Customized MR 7 Providing & Fixing ofConcealed Stop Cock With Trims as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 8 Providing & Fixing ofFloor Drainer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 9 Providing & Fixing ofWall hung Closet with Soft Close Seat Cover Fixed with Jumbo Bolts as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 10 Providing & Fixing of Concealed Cistern With Push Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 11 Providing and fixing of Under Counter Basin as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 12 Providing & fixing ofSensor Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 13 Providing & fixing ofUrinal With Sensor as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 14 Providing & fixing ofUrinal Division Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 15 Providing and fixing Sink Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 16 Providing and fixing 2 Way Bib Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 17 Providing & fixing Health Faucet as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 18 Providing and fixing of Angle Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 19 Providing and fixing of Bottle Trap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 20 Providing and fixing of Toilet Paper Holder as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 21 Providing and fixing of Towel Ring as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 22 Providing and fixing of Soap Dish as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 23 Providing and fixing of Waste Coupling as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 24 Providing and fixing of Long Braided Hos Pipe as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. MR 25 Providing and fixing of 10ltr Gyser as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-AO Smith/Equivalent MR 26 Providing and fixing of 110mm dia pipe 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 27 Providing and fixing of 110mm dia 90 Degree Elbow 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 28 Providing and fixing of 110mm dia 45 Degree Elbow, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 29 Providing and fixing of 110mm dia Coupler, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 30 Providing and fixing of 110mm dia Tee, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 31 Providing and fixing of 110x75mm dia Nahani Trap, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 32 Providing and fixing of 75mm dia pipe 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 33 Providing and fixing of 75mm dia 45 Degree Elbow, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 34 Providing and fixing of 75mm dia Coupler, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 35 Providing and fixing of 75mm dia Y Tee, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 36 INTERIOR WORK ESTIMATE 37 Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coatingof grade 350 as per IS 277and consisting of angle cleat 25x1.6mm with flanges of 27mm and 37mmat 1200mm c/c one flangedfix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia boltto the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ cshall be fixed in direction perpendicular to GI channels with connecting clipsmade out of 2.64MM diax230mm longGI wire at every junction including fixing the gypsumboard with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partitionwith help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixingto a flush finish of tapperedend sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting. 12.50mm thick tapered edge gypsum board.DSR-12.45.1 38 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. DSR -12.52.2 39 Providing & Fixing of Armstrong Suspended Ceiling System with Armstrong H4988 BP4988S DUNE Bev. Teg. 600x600x15mm (Microlook) EDGE TILES WITH ARMSTRONG Silhouette Exposed GRID. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm ,and 600x1200x15mm suitable for Green Building application, with Recycled content of 66% GW.The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm.Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and a load carrying capacity of 10 Kgs/M2.The Tile & Grid system used together, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge M.R 40 Providing & making false ceiling system with GI section frame work cladded with 12mm plySurface to be finished 4mm thick veenear complete with polishas per standard design all complete as per drawing and specification and direction of engineer incharge. M.R 41 Providing and fixing of 12 mm thick highglossLaminated wooden flooringrange grand illusion/studio Classification of Use 23/32 (Heavy Domestic/Domestic) with a Surface Abrasion Resistance of class AC3 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1212 mm X 137 mmhaving Uni fitlocking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge)Make-FloorMaster/Armstrong/Haro. all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Make-Armstrong,Mikasa,Luxe EquivalentM.R 42 Providing and laying of printed saxony carpet of CARUSBrand, manufactured by Beaulieu International Group or equivalent, having 100% Type 6 Nylon/Polyamide Crealon or equivalent and 1/10 gauge, . The carpet should have a primary backing of woven pp and secondary backing of weaveback to ensure high performance and comfort. The carpet should be of 4M width to ensure lesser joints and minimum wastage. It should have a minimum total weight of 1650 gsm and minimum pile weight 800 gsm , minimum number of tufts to be 185040 or more The carpet should also qualify to the following minimum European standards performance specifications - (a) Fastness to rubbing, dry(ISO 105 X-12), minimum rating should be 4-5; (b) Fatness to rubbing, wet (ISO 105 X-12), minimum rating should be 5; (c) Water fastness, (ISO 105 E-01), minimum rating should be 4-5; (d) Fastness to light (ISO 105 B-2), minimum rating should be 5; (e) Thermal Resistance (ISO 8302), minimum rating should be 0,072 m² K/ W; (f) Impact sound insulation (ISO 140 - 8), minimum rating should be 25dB. The carpet should be Scotchguard ready for better stain resistance, and should have an approved fire rating of Class 1 under Bf1S1 and should be recommended for commercial usage under Class 23/32 classification.duly installed on smooth hard floor with support of 10 mm epe sheet & company recommended adhesive.M.R 43 Providing & Making & Fixing of Commercial Wall Panneling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 12MM Ply complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 44 Providing & Making & Fixing of Commercial Wall Partition made with Aluminium Section of 2x1 @ 2CC frame work cladded with 9MM Ply on Both Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 45 Providing & fixing Toughned glass Parition with 12mm Modi float glass fixed edge to edge as per design and drawing and polished where required along with neccesary hardware all complete as per drawing, specification and direction of engineer incharge. M.R 46 Providing & Making & Fixing of Wall Panneling made with 1MM Laminate & 5.5MM MDF on Existing Surface complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 47 Providing & Making & Fixing of Wall Panneling made with 4MM Veneer on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 48 Providing & Making & Fixing of Wall Panneling made with 12MM Louver on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 49 Providing & Making & Fixing of Wall Panneling made with Coloured Lacquered Glass on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 50 Providing & Making & Fixing of Storage Cabinet made of 19mm board, having shelves & shutters & teak wood beading & finished surface of 1mm thick Laminateincluding all hardware like tower bolts, hinges, lock & handle as per approved drawing & direction of Engineer incharge.M.R 51 Providing and Fixing Channeled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm or as required by the Architect/ approving engineer, made of a high density particle board substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips. as per the approved designas approved by Engineer -in-Charge. M.R 52 Providing and supplying ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire -resistant fabric with an option of colours as per the choice of the Architect/ Person in-charge of size 1200x600 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers and construction adhesives as per the instructions laid down by the manufacturer as per the approved designas approved by Engineer -in-Charge. M.R 53 Providing & fixing of 12 mm Toughened Glass Door with all hardwareas per design with edge polish m/c top & bottom pivot and bottom lockwith handle all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 54 Providing & fixing of Flush Door Laminated both side complete with all fittings,Round mortis lock,door closer etc all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 55 Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 56 Providing & Fixing of Wall Paper of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 57 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. DSR-13.91 58 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR-13.80 59 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm DSR-13.48.1 60 Providing and laying of Double Charged floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200mmMR 61 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm DAR-11.41.2 62 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR-11.48.2 63 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm DSR-8.2.2.2 64 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.DSR-8.5 65 ELECTRICAL WORK ESTIMATE 66 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A DSR(1.10.1) 67 Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. DSR(1.31) 68 Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. DSR(1.32) 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR(1.14.1) 70 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR(1.14.2) 71 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire DSR(1.14.3) 72 Supplying & Drawing co-axial TV cable RG-6 grade, 0.7 mm. solidcopper conductor, PE insulated] shielded with fine finned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required. For T.V. Socket outlet DSR(1.19) 73 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM DSR(1.21.1) 74 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM DSR(1.21.2) 75 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM DSR(1.21.3) 76 Supply and fixing of recess mounting round15 TO 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAAS.I 1403 77 Supply and fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAAS.I 1406 78 Supplying & fixing of TV Antenna socket on Modular Plate & G.I Box including connections DSR(1.27.1+1.24.7+1.28.1) 79 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 1 or 2 ModuleDSR(1.28.1) 80 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 3 ModuleDSR(1.28.2) 81 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 4 ModuleDSR(1.28.3) 82 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 6 ModuleDSR(1.28.4) 83 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 8 ModuleDSR(1.28.5) 84 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 12 ModuleDSR(1.28.6) 85 Blank plate for modular plate type switch boards wherever required.DSR(1.26) 86 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm 3.5 core S.I 501(J) 87 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 25 sq. mm 3-1/2 coreS.I 503 (J) 88 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 25 sq. mmS.I 504 (E) 89 Supply and fixing of 6Amp to 32Amp SPMCB(10KA) C Curve CAT-A4 Pole Isolator CAT-AS.I 1002(A) 90 Supply and fixing of 63Amp 4 Pole Isolator CAT-AS.I 1007(B) 91 S & F surface/Flush mounting 12ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT-AS.I 1029(A) 92 Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable)DSR (1.53) 93 Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 94 Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 95 Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 96 Supply and fixing of 150mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 97 Supply and fixing of 250mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 98 Supply and Fixing of Deep Recess Mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 99 Supply & Fixing of Hanging Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 100 Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with 2nos RJ-45 Data outletM.R 101 IP UNIFIED COMMUNICATION & CCTV SYSTEM WORK 102 Supply, Installation, testing and commissioning of 42U Rack complete with standard accessories Make - Dlink/Comrack 103 Supply, Installation, testing and commissioning of Cat 6 patch panel, loaded. Make - Dlink 104 Supply, Installation, testing and commissioning of modular patch cables 1m 10/100/1000 Make - AMP/Molex/DC 105 Supply,Installation, testing and commissioning of 24 port POE switch 10/100/1000. Make - Dlink/Netgear 106 Supply, Installation, testing and commissioning of Dual Band Wave Wifi 6 Access Points. Make - Grandstream/Netgear 107 Supply,Installation, testing and commissioning of cat6 Informatio0n Outlets, non PCB Pyramid type. Make - Dlink/Amp/Molex 108 Supply, Installation, testing and commissioning of Dual Face Plates with clear labeling. Make - Dlink/Amp/Molex 109 Supply, Installation, testing and commissioning of Single Face Plates with clear labeling. Make - Dlink/Amp/Molex 110 Supply, Installation, testing and commissioning of IP fixed Cameras, Network TDN IR Indoor/Outdoor Camera, 1/3 CMOS, 2 MP, 3.6 mm Fixed, 24 IR LEDs,PoE,H.264complete. Make - Dahua 111 Supply, Installation, testing and commissioning of PTZ DOME Cameras, 4MP, 2.8mm CMOS image sensor, low illuminance, 2, 12V DC/PoE power supply, Network TDN IR Indoor/Outdoor IP67 Rated tamper proof complete. Make - Dahua/Hikvision 112 FIRE ALARM WORK 113 supplying , installation , Testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. DSR-17.1.2 114 supplying , installation , Testing & commissioning of manual call boxes of MS construction in surface/recess with strainless steel chain & hammer assembly complete with glass and push button etc. as required. DSR-17.1.3 115 supplying , installation , Testing & commissionin response indicator on surface/recess Ms box having two LEDs mettallic cover complete with all connections etc. as required.DSR-17.1.5 116 supplying , installation , Testing & commissionin fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. DSR-17.1.6 117 supplying , installation , Testing & commissionin of main control and indicating panel made out of 16 SWG MS sheet to accommodete the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all talk back master station with LED PTT ( press to talk ) push buttonfor operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc, complete as required-1 set Amplifier change over switch for inter changing amplifier-1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required -1 No. Gooseneck microphone with stand and ON/OFF switch-1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required-1 set. Battery charger trickle cum boost to take complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed mainenance free batteries-1 set. DSR-17.1.11 118 supplying , installation , Testing & commissioning of fire fighter telephone handset complete as required. DSR-17.2.17 119 CABLING & WIRINGDSR-17.5 120 supplying & laying of 2* 1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.DSR-17.5.2 121 supplying & drawing of cable fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steelconduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Two pair, 2-core , 1.5 sqmmDSR-17.5.3 122 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required DSR-17.5.4 123 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 4.5 Kg capacity CO2 type as per IS- 15683complete as per specification and fixed / install as per site condition: MR 124 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 5 Kg capacity ABC Dry Chemical powderas per IS- 15683complete as per specification and fixed / install as per site condition : MR. 125 Supply, Installation testing and commissioning of Ceiling mounted automatic fire extinguisher (Dry Chemical powder) of 10KG capacity including all fitting and accessories as per dwg and spec as complete required. MR. 126 Supply,Installation, Testing & Commissioning of 3 Nos. G.I. sand buckets painted Red Color complete with suitable size G.I. stand duly painted Red Color of suitable size to hang 3 Buckets at a time as per required specifications. MR. 127 VRV AIR-CONDITIONING WORK 128 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 41.3 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 129 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 34.9 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 130 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 28.6 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 131 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 22.2 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 132 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 19.1 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 133 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 15.9 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 134 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 12.7 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 135 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 9.5 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 136 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 6.4 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 137 Providing & Laying of Cable tray for copper pipe 300MMall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 138 Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 32 mm dia with 6 MM thicknessall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 139 Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 25 mm dia with 6 MM thicknessall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 140 Providing &fixing control cumtransmission wiring ofcopper in suitable conduits between indoorand out door unitall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 141 Supply & Laying of M S Slotted Angle for pipes and cables horizontaly and vertically along with threaded rod, nut, bolt, saddle, tie etcall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 142 Wall Chaseing as per site requirement all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 143 Making Core cutting in Walls, Beams, RCC structure as per site requirement all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 144 Supply, Installation, Testing & Commissioning of DAIKINBRANDVRV OUTDOOR UNIT MODEL 22 HP HEAT PUMPRXYQ12ARY6+RXYQ10ARY6+BHF22P1006 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 145 Supply, Installation, Testing & Commissioning of DAIKINBRANDVRV OUTDOOR UNIT MODEL 44HP HEAT PUMP RXYQ20ARY6+RXYQ12ARY6+BHF22P1516 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 146 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 0.66 TR + Corded Remote + Refnet, Model FXAQ20 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 147 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 0.83 TR + Corded Remote + Refnet, Model FXAQ25all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 148 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.06 TR + Corded Remote + Refnet, Model FXAQ32all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 149 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.32 TR + Corded Remote + Refnet, Model FXAQ40all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 150 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.65 TR + Corded Remote + Refnet, Model FXAQ50all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 151 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 2.08 TR + Corded Remote + Refnet, Model FXAQ63all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 152 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 2.65TR + Corded Remote + Refnet, Model FXFSQ80all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 153 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 3.31TR + Corded Remote + Refnet, Model FXFSQ100all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 154 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 4.13 TR + Corded Remote + Refnet, Model-FXFSQ125all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 155 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Outdoor Unitall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 156 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Hi Wall Unitsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 157 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Cassette Type Unitsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 158 Commissioning of VRV systems including topping R410A gas per site requirementsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 159 DRIVEWAY WORK 160 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.DSR-(16.83) 161 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). DSR-(16.84) 162 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. DSR-(16.91) 163 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR - 4.1.8 164 Providing & Layingof 15 mm thickHeavy duty Exterior floor tiles of approved Brand and sample in size 600 x 600 mm which will be cutted in different sizes as per app. design with 3 to 6 mm spacer offirst quality of Bell, Johnson, Kajaria or equal make, shade, colour, and pattern as app. by engineer Incharge laid over base cement mortar 1:4 mix including finishing the joint with white cementand to make the joint as perthe approved design, drawing and specification and direction of EI. MR 165 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR(11.48.2) 166 FURNITURE ESTIMATE 167 Providing, Making & Fixing of Executive Wooden Court Room Dais of Size (3000Lx1200Wx750HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 168 Table of Size - 1950W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1500W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves, Make-Featherlite/Geeken/Hof/Equivalent 169 Table of Size - 1800W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1350W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves, Make-Featherlite/Geeken/Hof/Equivalent 170 Table of Size - 1500W X 750D X 750HT Having Side Storage of - 900W X 450D X 750HT. The main table shall be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. Soft closing access flap with in-built power box to be provided on work surface for wire management. Return table Work Surface should be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. PLB will be E1-P2 grade and approved shade. Confirming to IS-12823:1990. 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The edge band material should have Shore D hardness of 79± 4. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification confirming to ASTM D 4499 standards for viscosity and thermal stability. The edges should be PVC Edge banded with matching finish or have an option of reverse water fall edges.Modesty Panel shall be made of 18mm thick PLT both sides pre-laminate board confirming to IS-14587:1998.The height of modesty shall be 450 mm.The modesty panel will be connected to the main table by 2 nos special Aluminum extruded brackets. The modesty will be fixed 150 mm from the edge of the table. • Cable management: The table will be provided with suitable grommet hole. Legs and Supports:- The MS supports are made of 55 x55mm diamond shape loop leg ERW tubes- 16g with levelers to cater for floor undulations- +/- 20 mm. ERW Tube confirming to IS 4923 : 1997 – 16g. Main leg members will be connected through a horizontal member size 1.6mm thk, 60x40 cold formed ERW tube confirming to IS 4923: 1997. The vertical and the horizontal tubes will be welded with CO2 MIG welding process confirming to IS 816 and ISO 9692-2. The leg will be fabricated using Argon & Co2 gas mixture on a Robotic welding machine to ensure adequate welding strength with consistency.• The legs will be connected with Cross beams to take care of the bending stress catering up to 1800 mm length and up to 900 mm depth of the work surface. Finish:- All metal components & aluminum die cast parts will be powder coated by Nano ceramic surface treatment process compiled to a Bend test-ASTM D3451 – 06, Adhesion -DIN EN 14901 Salt spray test- DIN EN ISO 9227, which is non-hazardous, environmental friendly and will have uniform powder coating thickness of 50-60-micron thickness.Wire Management: Make-Featherlite/Geeken/Hof/Equivalent 171 Providing, Making & Fixing of Wooden Table of Size (1350Lx675Wx750HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 172 Providing, Making & Fixing of Wooden Linear Workstation Table Having Keyboard Tray & Cable Manager Made of 1 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 173 Liner Workstation of Size:- 1350W X 600D X 750HT AND 300HT HEIGHT Specifications: Table Top - 25mm thick Pre Lam particle board with 2mm edge lipping on all exposed sides. Support - MS powder coated diamond shape leg of 55X55mm size with die cast connectors and supporting MS cross beams. Main Screen:- Aluminum anodised 30mm scree n with fabric magnetic and glass marker tiles. Privacy Screen:- 6mm thick acrylic screen on studs. Wiremanagement - 450mm metal flip up with provision to mount switches and sockets on MS cable tray and vertical wire entry cover between the intermeidate leg for power and data. Model - MAX-1 Make-Featherlite/Geeken/Hof/Equivalent 174 Providing, Making & Fixing of Wooden Linear Printer Table,Made of 1 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized. 175 Providing And Fixing of Confference Table Made 0f 19MM thick ply board,Top in 3 layers and virtical drop 3 Lair 19MM ply board. All the surface to be cladded with 4MM thick Veener And S.S Fram square section 302 grad frame. All the edges to be lipped with 4MM Veneer polished in matching colour.As per the design. as per E/I. (Greenply/Luxe or Equivalent ISI Make) Customized 176 Providing, Making & Fixing of Wooden Witness Box of Encloser Size (1050Lx900Dx1050HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 177 Providing, Making & Fixing of Back Storage of Size (3000Lx450Wx700HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge.Customized 178 Providing, Making & Fixing of Back Storage of Size (1800Lx450Wx700HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 179 Providing & Fixing of Wooden Storage, Particle Board Structure, (1500x450x900), Model-Storage-9, Make-Geeken, all complete as per design approved by E/I & Architect Incharge. 180 Side Storage of Size 900Wx450Dx750HT will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 181 Providing, Making & Fixing of TV Pannel of Size (2100Lx450Wx750HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 182 High Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control is below the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair will have adjustable headrestChair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 MODEL, Chair should be BIFMA and Green Guard certified.:- AMAZE HB,Make-Featherlite/Geeken/Hof/Equivalent Model-GA 5003 all complete as per design approved by E/I & Architect I 183 Medium Back chair Having Base: Nylon Base- The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and confirming to ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards. The base shall be 67 cm pitch-center diameter -77 cm with castors. MS ring will be insert molded for better grip in the swaged taper. Castors: Twin Castors 50mm dia complying to ANSI / BIFMA X 5.1 – 2002. Castors will be made in PP.The axle pin will be rust protected- Zinc pacified. The pin should be designed to have push fit with lock ring. RoHS compliant castors. Gas lift: Standard Gas lift 100 mm stroke with pneumatic height adjustment as per the seat height criteria.- Class 4 as per ANSI BIFMA performance standards. Possibility to increase the seat height if required with Gas lift stroke- 110 -125 mm. Mechanism:Centre Tilt Mechanism:compact and stable with 8″ x 6″ mount holes as per European Standard. Initial seat angle of 3 degrees and full recline angle of 20 degrees for ergonomic comfort. Provided with common leverfor locking and up/down adjustment and horizontal movement of the lever to engage and disengage lock at upright positionLever provided for rotational movementto operate gas lift and adjust chair height to user specification. Full length plastic knob provided to cover lever bar giving better aesthetical appeal to the mechanism. Knob provided to adjust spring tension to suit individual user in order to ensure maximum chair comfort. Arms:Fixed Arms Injected molded arms- polyurethane 20% GF nylon. The polypropylene arms will have steel inserts. The arm profile should blend with the back profile without gap. Seat: Seat Height- 450-540mm with hydraulic height adjustability of 90-100mm. Seat Width & Height- Size of the chair shall be -Back: 45.0cm. (w) x 59.0cm.(H) .Seat: 48.0cm (w) X 49.0cm.(D). Chair back should be connected to the Polyurethane arms for achieving comfortable seating posture.Effective back height from Seat - 560mm, Ply wood- 12 mm thick with 7 ply. Fire retardant type exterior grade phenol formaldehyde bonded. It will be hot pressed ply - conforming to I.S.I. 5509. The arm and back shall be fixed together to the seat with Allen bolts.The bolts will be screwed to the “T” nuts fixed to the plywood seat.Fabric: Upholstery:Seat & Back are duly upholstered with approved fabric. The back should have the option of mesh back AN-70 (black) and AN-75(grey). GSM for mesh 340. No flaming or progressive smolderingwithin one hour of placement of the cigarettes. Fire rated fabric confirming to BSEN 1021 and IS 15061-2012 Foam: Seat cushion with pre molded foam of 50 - 60 density in the shape of plywood.Density -- 52 kg/m3, Hardness -- 12.6kgf at 25%- Back cushion- density- 32g/sq in. Back:Mesh back on injected molded PP with 30% GF nylon. The back should have the option of mesh or fabric back. The mesh will be GSM 340 grade. . ALPHA MB, Make-Featherlite/Geeken Equivalent. 184 Fixed Leg Chair Made of The frame is made out of 25.4mm tube of 16 gauge tube confirming to IS-7138-1973, Welded by Co2 welding process for uniform surface finish and higher tensile strength perforation on the sheet is of uniform 2.5mm dimension and gives good ventilation.High quality hardware conforming to Hardness 38-44 and tensile strength – 1300 n/mm. IS 1363-1967.Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Japanese T-nuts and riveted in to the plywood.Set and backUpholstery: Cushion with pre-moulded foam of 50 - 60kg/m3 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Injection moulded polypropylene armrests.Leatherette cusion Back on Frame. Back is injected moulded PP.Seat and back are duly upholstered with approved Leatherette. AMAZE VA, Make-Featherlite/Geeken/Hof/Equivalent 185 Providing & Fixing of 3 Seater Sofa, Aluminium Arm And Leg, Powder Coated Cross Beam, Metal Insert PU Seat Back Size in mm - 1625(L) X660(D) X 870(H) Having 3 Seater With 4 Arm, Model-Fly-2, Make-Featherlite/Geeken/Hof/Equivalent, all complete as per design approved by E/I & Architect Incharge. 186 Providing, Making & Fixing of High Back Chair As per Design Approved made of teak wood having high density foam of sleepwell brand, upholstered in approved fabric/leatherrete. Wooden part to be finished in melamine polish, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge.Customized 187 GUARD-1 ROOM WORK 188 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil , DSR-2.8.1 189 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR-4.1.8 190 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. DSR-2.27 191 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):1).Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of300mm including excavation channel along the wall & rodding etc. complete: 2).Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 3).Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. 4).Treatment of existing masonry using chemical emulsion@ one litre per hole at 300mm interval includingdrilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement : 2 coarse sand) to the full depth of the hole. 5).Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downwardangle of 45degree at 150mm centre to centre and sealingthe same.All with With chlorpyriphos/Lindane E.C. 20% with 1% concentration. DSR-2.35.1+2.35.2+2.35.3+2.35.3+2.35.4+2.35.5 192 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum.Concrete of M25 grade with minimum cement contect of 300 kg/cum (For Foundation) DSR-5.33.1.1 193 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Column) DSR-5.33.2.1 194 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Beam) DSR-5.33.2.1 195 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Slab) DSR-5.33.2.1 196 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Lintel) DSR-5.33.2.1 197 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.1.1 198 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.4.1 199 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R.-4.10 200 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approv quality using 1.7 kg per square metre on damp proof course after cleaning the surface w brushes and finally with a piece of cloth lightly soaked in kerosene oil. D.S.R.-4.13 201 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6 202 12 mm Cement plaster of mix.1:4 (1 cement: 4 course sand) DSR-13.4.1 203 15 mm cement plaster in single coat on rough side of single or half brick wall 1:4 (1 cement: 4 course sand) DSR-13.5.1 204 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1) cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deepThe whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thickness at khurra as 65 mm DSR-22.7 205 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns. DSR-5.9.1 206 Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. DSR-5.9.3 207 Centering and shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR-5.9.5 208 Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts. DSR-5.9.6 209 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 210 GUARD-2 ROOM WORK 211 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil , DSR-2.8.1 212 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR-4.1.8 213 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. DSR-2.27 214 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):1).Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of300mm including excavation channel along the wall & rodding etc. complete: 2).Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 3).Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. 4).Treatment of existing masonry using chemical emulsion@ one litre per hole at 300mm interval includingdrilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement : 2 coarse sand) to the full depth of the hole. 5).Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downwardangle of 45degree at 150mm centre to centre and sealingthe same.All with With chlorpyriphos/Lindane E.C. 20% with 1% concentration. DSR-2.35.1+2.35.2+2.35.3+2.35.3+2.35.4+2.35.5 215 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum.Concrete of M25 grade with minimum cement contect of 300 kg/cum (For Foundation) DSR-5.33.1.1 216 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Column) DSR-5.33.2.1 217 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Beam) DSR-5.33.2.1 218 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Slab) DSR-5.33.2.1 219 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Lintel) DSR-5.33.2.1 220 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.1.1 221 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.4.1 222 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R.-4.10 223 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approv quality using 1.7 kg per square metre on damp proof course after cleaning the surface w brushes and finally with a piece of cloth lightly soaked in kerosene oil. D.S.R.-4.13 224 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6 225 12 mm Cement plaster of mix.1:4 (1 cement: 4 course sand) DSR-13.4.1 226 15 mm cement plaster in single coat on rough side of single or half brick wall 1:4 (1 cement: 4 course sand) DSR-13.5.1 227 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1) cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deepThe whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thickness at khurra as 65 mm DSR-22.7 228 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns. DSR-5.9.1 229 Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. DSR-5.9.3 230 Centering and shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR-5.9.5 231 Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts. DSR-5.9.6 232 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 233 LT PANNEL DG SET WORKS 234 DG Set- BACKSIDE OF THE BUILDING 235 Supply of 250 KVA DG Set Cummins/ Mahindrol 236 b DG set installation and associted works 237 LT CUM AMF PANEL - ELECTRICAL ROOM 238 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction extendable type LT CUM AMF Panel, suitable for operation on 415 ±10%volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 2mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPNAluminium bus bars of high conductivity, SMC bus bar supports, with bottom base channel of section not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connectionwith solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawingandtechnical specifications etc. 239 INCOMER FOR TRANSFOMER4 No. 240 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 241 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 242 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 243 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 244 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 245 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 246 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 247 INCOMER FOR DG1 No. 248 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 249 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 250 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 251 Multifunction Meter-Load Manager with RS485 port, Parameters: V, A, F, PF, W/VA, Wh /VAh, Runhrs, Onhrs & Interupts & Suppression Current (5 to 99 mA), Acc. Cl: 1.0, 3Ph, Operating voltage: 80 to 480V AC, Size: 96X96, Model: EM6436H CONZERV/SECURE 1 No. 252 400/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 55mm PROCOM 1 No. 253 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 254 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 255 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 256 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 257 SERVO BY-PASS ARRANGEMENT2 No. 258 400A 4P Front operated By-pass Switch with External Handle, bridging bars & Interphase Barrier, Type: SIRCOVER BYPASS SOCOMEC/C&S/HPL 1 No. 259 CHANGE OVER SECTION FOR PHASE CORRECTION2 No. 260 400A 4P ATS with bridging bars,Type: ATyS r SOCOMEC/C&S/HPL 1 No. 261 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation1 No. 262 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 263 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 264 Phase Sequence Relay, 3Ph-3W, Protection: Phase failure, Phase sequence, Phase asymmetry, DIN rail mount, 1C/O, Supply Voltage: 154V-500V AC (L-L), Model: 800PSR1 No. 265 14 PIN MINIATURE RELAY WITH BASE 230V AC 1 No. 266 AMF LOGIC WITH CONTROL MCBs1 No. 267 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 9 No. 268 10A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 269 10A 2P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 270 On Delay / Interval Timer, Time Range: 3 Sec to 60 Mins, 2 C/O, Voltage: 20 to 240V AC & 12to 240V DC, Type: 800XA3 No. 271 Digital Voltage Protection Relay, 3Ph-3W/ 3Ph-4W, Protection: Under / Over voltage, Phase failure, Phase sequence, Phase asymmetry, Under / Over frequency, Neutral loss, 2 x 1C/O, Supply Voltage: Self powered, Model: 900VPR2 No. 272 14 PIN MNIATURE RELAY WITH BASE 3 No. 273 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 274 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 275 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 276 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 2 No. 277 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 2 No. 278 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 1 No. 279 Green 22.5mm Flush Type Spring Return Non-Illuminated (Metallic) Push Button, Contacts: 1NO C&S/VAISHNO 1 No. 280 Red 22.5mm Flush Type Spring Return Non-Illuminated (Metallic) Push Button, Contacts: 1NC C&S/VAISHNO 2 No. 281 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation1 No. 282 12 ,10A BATTERY CHANGER1 No. 283 EMARGENCY 284 BUSCOUPLER1 No. 285 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 286 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 287 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 288 AC3: 250A AC1: 300A 3P Power Contactor, Coil: 220V AC, Type: LC1E SCHNEIDER/ABB/L&T 1 No. 289 Auxiliary Contact Block, Front Mounting, Contacts: 1NO+1NC for LC1E06-E630/LC1E0600-LC1E9500 SCHNEIDER/ABB/L&T 1 No. 290 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 291 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 292 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 293 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 294 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 No. 295 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 5 No. 296 BUS BAR No. 297 400A TPN, 50KA aluminium bus bar with coloured heat shrinkable insulated sleeve. No. 298 Outgoing 299 OUT GOING 250A MCCB1 No. 300 250A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 4 No. 301 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 4 No. 302 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 8 No. 303 VAF, PF Meter, Acc. Cl: 1.0, Model: DM6100 CONZERV/SECURE 1 No. 304 250/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 45mm PROCOM 1 No. 305 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 306 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 307 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 308 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 No. 309 OUT GOING 200A FP MCCB2 No. 310 200A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS1 No. 311 Standard extended rotary handle for EasyPact CVS 100/160/250A1 No. 312 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A2 No. 313 OUT GOING 160A FP MCCB6 No. 314 160A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 315 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 1 No. 316 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 2 No. 317 OUT GOING 100A FP MCCB2 No. 318 100A 4P 25kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 319 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 1 No. 320 Spreader Links (Set of 4) 4P for EasyPact CVS 100A SCHNEIDER/ABB/L&T 2 No. 321 OUT GOING 63A FP MCCB2 No. 322 63A 4P 10kA C-Curve MCB,Type: xC60 SCHNEIDER/ABB/L&T 2 No. 323 75KVAr APFC PANEL - ELECTICAL ROOM 324 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction APFC Panel, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 325 APFC PANEL INCOMER 1 Nos. 326 200A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 Nos. 327 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 2 Nos. 328 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 1 Nos. 329 5 Steps 240V AC Power Factor Controller Relay with 3CT, 3PH-4W, Type: BR50001 Nos. 330 Multifunction Meter-Load Manager with RS485 port, Parameters: V, A, F, PF, W/VA, Wh /VAh, Runhrs, Onhrs & Interupts & Suppression Current (5 to 99 mA), Acc. Cl: 1.0, 3Ph, Operating voltage: 80 to 480V AC, Size: 96X96, Model: EM6436H CONZERV/SECURE 9 Nos. 331 200/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 30mm PROCOM 1 Nos. 332 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 333 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 3 Nos. 334 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 4 Nos. 335 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 336 CAPACITOR BANK SECTION Nos. 337 25KVAR BANK2 Nos. 338 100A 3P 25kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 Nos. 339 Spreader Links (Set of 3) 3P for EasyPact CVS 100A SCHNEIDER/ABB/L&T 2 Nos. 340 25kVAr 3Ph Heavy Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 341 AC3: 50A AC1: 80A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NO+1NC, Type: LC1D SCHNEIDER/ABB/L&T 1 Nos. 342 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 343 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 344 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 345 10KVAR BANK2 Nos. 346 63A 3P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 347 10kVAr 3Ph Normal Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 348 AC3: 25A AC1: 40A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NO+1NC, Type: LC1D SCHNEIDER/ABB/L&T 1 Nos. 349 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 350 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 351 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 352 5KVAR BANK1 Nos. 353 32A 4P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 354 5kVAr 3Ph Normal Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 355 AC3: 16A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NC, Type: LC1K SCHNEIDER/ABB/L&T 1 Nos. 356 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 357 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 358 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 359 LTDB - 2 ON EVERY FLOOR 360 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction LTDB, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for Enclosure, 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 361 160A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS 362 Standard extended rotary handle for EasyPact CVS 100/160/250A 363 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A 364 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T (1.0 Nos) 365 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T(1.0 Nos) 366 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T (2.0 Nos) 367 6A 1P 10kA C-Curve MCB,Type: K60H C&S/VAISHNO (3.0 Nos) 368 CABLES 369 Supply of 185SQMM 3.5 core LT aluminum PVC Insulated armoured cables. - FROM MAIN TRANSFORMER TO LT PANEL 370 Supply of 95SQMM 3.5 core aluminum Armoured - MAIN LT PANEL TO LTDB 371 Supply of 2.5SQMM 2 core Copper Armoured - BOUNDRY WALL LIGHTS CONNECTIONS 372 END TERMINATION - MAIN LT PANNEL & LTDB 373 185Sqmm End termination with materials 374 95Sqmm End termination with materials 375 EARTHING - OUTSIDE ELECTRICAL ROOM 376 GI Earthing 377 Copper Earthing 378 Supply & Laying of 25X3 GI strip with nut bolt & washers 379 LABOUR CHARGE ( FOR INSTALLATION OF LT PANEL, APFC PANEL, LTDB & LAYING OF CABLE) 380 WATER PROOFING & RAINWATER WORKS 381 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth , Pipes 80 mm to 300 mmdiameter DSR - 2.10.1.2 382 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR - 12.22 383 Providing and fixing of water proofing layer on the terrace on the exsisting floor of the terrace without removing the exsisting layer of PCC only cleaning included as per specMR 384 Constructing masonry Chamber 60X60X75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR - 18.33.1 385 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ringconforming to IS: 5382 leaving 10mm gap forthermal expansion. - 110 MM DSR - 12.41.2 386 Providing of open drainAR 387 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Providing & fixing of door / windows grill. DRS -10.25.2 388 Landscraping work 389 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR-(2.31) 390 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR - 4.1.8 391 Providing & Layingof 15 mm thickHeavy duty Exterior floor tiles of approved Brand and sample in size 600 x 600 mm which will be cutted in different sizes as per app. design with 3 to 6 mm spacer offirst quality of Bell, Johnson, Kajaria or equal make, shade, colour, and pattern as app. by engineer Incharge laid over base cement mortar 1:4 mix including finishing the joint with white cementand to make the joint as perthe approved design, drawing and specification and direction of EI. MR 392 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR(11.48.2) 393 Brick Workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) DSR-6.4.2 394 supply and installation of steel bolads at propoer distance as directed by the architect inchargeMR 395 Supply and installation of stone benches as per layout and designas directed by the architect inchargeMR 396 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement, 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage wherever required complete etc. as per direction of Engineer- in- charge ( length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by Engineer - in - charge). DSR-16.69 397 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. DSR- 10.16.1 398 CIVIL-FACADE ESTIMATE 399 Dismentling of RCC work i/c stacking of dismantled material as directed by EI with in distance 50 Mtrs.DSR 15.3 400 Dismentling of RB work i/c stacking of dismantled material as directed by EI with in distance 50 Mtrs.DSR 15.4 401 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area Beyond 3 sq.DSR 15.12.2 402 Dismentling of existing plasterand i/c stacking of dismantled material as directed by EI with in distance 60 mtrsDSR 15.56 403 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 15.60 404 12 mm cement plaster with 1:4 cement & coarsesand of 1.25 FMin single coatof single or half brick wall for interior plastering upto floor two level. DSR 13.4.1 405 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) DSR 14.1.2 406 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR 4.1.8 407 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once for every month for duration of scaffolding (Maximum 3 Months).DSR - 14.72 408 Providing & Fixing of Cluster Stone Brick Stamping of Size (8.46x2.36) & 13MM (Approx) Thick having Super Hard outer shell on Vertical Surface with uncoloured Adhesive FS complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 409 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. M.R 410 Providing & Fixing of Roller Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 411 Providing & Fixing of Zebra Blinds with Hand Railof approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 412 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. DSR 25.1 413 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (Making Louvers & Groves) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including:Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design ) Providing, fabricating and supplying and fixing panels of aluminum composite panel cladding in Pan shape of approved shades made out of 3mm thick aluminum composite panel material consisting of 2.40mm thick non toxic low density polyethylene virgin core sandwiched between two Aluminum coated sheets (each 0.3mm thickof AA 3105 Alloy grade). The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500 based/hylar 5000PVDF / Lumiflon based fluoropolymer resin lead 4.10 to 4.30 kg per sqm., nuts, bolts, washers, cleat drawings.DSR 25.2 414 Scraping of old white or colour wash including disposal of refuse as directed by EI with in distance 60 mtrs.DSR 13.88 415 Providing & Applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over plastered surface to prapare the surface even & smooth complete.DSR 13.80 416 Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 DSR 13.45.1 417 ELECTRICAL WORK ESTIMATE 418 Supply and fixing of Decorative 45 Watt LED Post Top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 6565 Make-Klite, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-ChargeMR 419 Supply and fixing of Decorative small decorate light withdirect dim light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to , all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-ChargeMR 420 Supply and fixing of 200 AMP MCCB Box with load diverter for the connections to the guard room for the landscape lightsMR 421 Providing and laying of 2.5MM 3.5 core copper armored cable for street light connections as per specs MR 422 Providing and Fixing of RCC round base with foundation of bolts and spces for the 45 Watt LED Post Top indirect light luminaireMR 423 BOUNDRY WALL WORK RATE ANALYSIS FOR (2.5MTR) 424 Brick Workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) DSR-6.4.2 425 Lime plaster 1:1:1 (1 lime putty : 1 surkhi : 1 finesand) INTACH SOR 2016 9.2.1 426 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DRS -10.25.2 427 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture DSR - 13.48.3 428 Supply and fixing of decorative plate on ms grill ralling with cold pressed impresion of fish and andaaz awadh as per specs.MR
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
32.
Public Administrative Department #9470844 Technical Bid
Tender For Drainage Of Rain Water Under Basantkunj Housing Scheme, Construction Of 400 Kl Cashmere Flood Pumping Station Similar To Barikala Barrel Behind Rashtra Prerna Isthal And Its Maintenance And Operation For 05 Years. - PART-A (400 KL Sumpwell)-CIVIL WORK 2 Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30cm in depth. 1 5m in width as well as 10 sqm on plan) including disposal of excavated carth, lead upto Som and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (Analysis Rate) 3 0.0 to 1.50 Mtr 4 1.50 to 3.0 Mtr 5 3.0 to 4.50 6 4.50 to 6.0 Mtr 7 Providing and laying in cement concrete 1:4:8 (1 cement 4 coarse sand 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form work, in foundation and floors. (DSR 4.1.8) 8 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) 300 mm dia (DSR - 20.3.1*0.8667) 9 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength, including pumping of concrete to site of laying curing, carriage for all leads, but excluding the cost of centering. shuttering, finishing and reinforcement as per direction of the engineer in charge for the following grades of concrete.Note Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement Concrete of M30 grade with minimum cement content of 350 kg/cum (For R.C.C. Lintel) For 398 kg/Cum. All works upto plinth Civil (DSR - 5.33.2.2) 10 RCC FOOTING AND RAFT 11 RCC SUMP WALL AND INTAKE CHANNEL 12 RCC COLUMN 13 RCC LINTEL 14 RCC BEAM 15 RCC SLAB, CSS and DG PLATFORM 16 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level (Sanctioned Rate) 17 Brick work in below plinth level including necessary cutting and moulding of brick work as required and also inchading honeycombed brick work in thickness of wall more than 12cms (1:6 cement & coarse sand I cement 6 coarse sand) (DSR 6.4.2) 18 Brick work in super-structure above plinth level including necessary cutting and moulding of brick work as required and also inchading honeycombed brick work in thickness of wall more than 12cms (1:6 cement & coarse sand I cement 6 coarse sand) (DSR 6.4.2) 19 12 mun cement plaster of mix: 1:6 (1 cement: 6 Fine sand) (DSR 13.1.2) 20 12 mm cement plaster on the fair side of single or half brick wall of mix :1:6 (1 cement: 6 Fine sand)(DSR 13.1.2) 21 Cement plaster 1.3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement 20 mm cement plaster. (DSR 13.9.2) 22 supply spreading, levelling and compacting earth in the campus for satisfaction Engineer Incharge. 23 Supply & fixing of flush doors commercial quality conforming to IS 2202 Part I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally (a) 31mm thick (DSR 9.21.2) 24 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods, gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required complete. 25 Providing & Fixing of Door/Windows grill (DSR 10.26.1) 26 Z-Section steel windows. (DSR 10.25.2) 27 Angle Iron Door Chaukhat 40*40*5 (DSR 10.31) 28 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface)(DSR 13.82.2) 29 Finishing walls with water-proofing on cement paint of approved make such as super snowcem, durrocem, robiacem, guttucem, supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white cement primer to give an even shade after thoroughly brushing the surface to powdered materials including curing and cost of all materials (DSR 13.44.1) 30 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (For Ceiling) (DSR 13.88.2) 31 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws ect. Complete. (DSR - 9.63.1) 32 250 mm x 10 mm 33 200 mm x 10 mm 34 Providing and fixing ISI marked oxidised MS handles conforming to ES 4992 with necessary screws. ec complete 125 mm(DSR - 9.66.1*0.8667) 35 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small acies not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3 Hi-gloss apcolite superla:, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt dust and other foreign maiter sand papering and stoping including cost of all itaterials labour tools and plants etc required for proper completion of the work (DSR 13.53.1) 36 Same as item 21 above but on new wood surface (DSR 13.61.1) 37 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies terraces etc consisting of following operations a) Applying a slurry coat of neat cement using 275 kg/sqm of cement admixed with water proofing compound confornung to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment b) Laying brick bats with mortar using broken bricks/brick bais 25 mm to 115 mm size with 50% of cement mortar 15 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 15 (cement 5 coane sand) admixed with water proofing compound.IS 2645 and approved by Engineer-in-charge to requned slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper canng applying a second coat of cement slurry using 2.75 kg sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge di Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge including 1 (DSR 22.7.1) 38 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC. kitchen and the like consisting of 1) Ist course of applying cement slurry 4, 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface) IInd course of 20mm cement plaster 13 (1 cement 3 coarse sand) maxed with water proofing compound in recommended proportion mcluding rounding off junction of vertical and horizontal surface IIIrd course of applying blown or residual bitumen applied hot at 17 Kg per sqm of area iv) IVth course of 400 micron thick PVC sheet (Overlaps at jomts of PVC sheet should be 100 mm wide and pasted to cach other with bitumen 17 Kg/sqm)(DSR - 22.5) 39 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior. sewage & water treatment plant, tunnels subway and bridge deck etc at the time of transporting of concrete into the drum of the ready-mix trick, using integral crystalline admixture 0.80% (marumum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in AC1-212-3R- 2010 ie by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be camed out all complete as per specification and the direction of the Engineer- m-charge The product performance shall carry guarantee for 10 years against any leakage (DSR - 22.22*) 40 Providing and laying Ceramic glazed floor tiles of size 300x300 mm ckness to be specified by the manufacturer) of ist quality conforming IS15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 14 (1 Cement 4 Coarse sand), Jointing with grey cement slurry 3.3 kg xsq.mm including pointing the joints with white cement and matching pigment etc complete. (DSR - 11.37*) 41 Cement concrete flooring 1 cement 2 coarse sand 4 graded. one aggregate) finished with a floating coat of neat cement, including cenen siurry, but excluding the cost of nosing of steps etc complete) mun thick with 20 mm nominal size stone. (DSR 11.3.1) 42 Centering and Shuttering including strutting, propping etc. and removal. 43 Suspended floors. Roofs, landings, balconies and access platform. (DSR - 5.9.3*) 44 Lintels. Beams. Plinth beams, girders, bressumers and cantilevers. (DSR - 5.9.5) 45 Vertical wall, Columns. Pillars, Piers, Abutments. Posts and Struts. (DSR - 5.9.6*) 46 Dewatering of Sump during Construction period and flooding conditions 47 PART-B (E/M WORK) 48 Supply, Installation Testing & Commissioning of Electric sewage VT Propeller Axial Flow Pumping plant including level sensor for auto operation, column assembly ,Suction Stainer. Tee ,Reducer, coupling with all connected Equipment etc all Complete (Kirloskar, Flowmore or Equivalent Make, relevant to IS/B3 Standard )13000 LPM capacity ,12 M head , complete in all respect.Pumpset Data Sheets Liquid - Storm Water/Flood WaterSp. Gravity - 1.10Pump Capacity - 13000 lpmPump Size - 12Pump Speed - 1500 RPMDischage - 780 m3Bowl eff. - 82%Lubrication - waterMotor Rating - 45 KWSpeed - 1500 RPMMake - ABBVoltage - 415frq - 50 Hz.T & P - vertical - Solid shaf-1Load DetailPump - 2000 KG (Approx)Motor - 400 KG (Approx)Details of discharge flangeas per IS - 1538 (300 NB)MOCCasing :1.5-2% NiCI FG 260Impeller :CF8M OR latest advance material, line-impeller Shaft/coupling-SS410, Col. pipe, dischare hood: MS 49 Supply, Installation Testing & Commissioning of LT Starter Panel (mains and stater ) suitable for above Pump with required Civil work and Complete in all respect.Supply of LT panel with Three incoming ( 2 CSS +1 DG set) , AMP panel, APFC panel , Phase reversal and all safety measeres and6 outgoing for pump, EOT crane, light & fan, for spare of PPT, Suitable capacity of Fully Automatic Star Delta Starter of MAKE ABB/ L&T/ Eqv. , comprisingwith following item as per given below.l. Contactor of suitable ratings. m. TOR of Suitable ratings.n. PB Switcheso. Dual Amp & Voltmeterp. Amp meter Selector Switchq. Toggle Switchesr. Indicating Lamps Phase Failures. Phase reversal relayt. Single phase preventeru. Capacitor of suitable ratings.v. GSM 50 Supply, Installation Testing & Commissioning of NR Valve special design for sewage purpose. Flanged end as per IS : 5312 Body, Cover-CI IS : 210, Gr. FG260 Door-CI IS : 210 Gr. FG260 Body Ring - bronze IS : 318 Gr. LTB2 Door Face - Natural Rubber Hinge Pin - SS ASTM A276 Type 410 Fasteners - CS IS : 1367, CL - 4.6/4.0 Gasket-Natural Rubber Flange Drilling - IS : 1538, Table 4 & 6 51 300 mm dia. 52 600 mm dia. 53 Supply, Installation Testing & Commissioning of Cast Iron Rising Spindle Sluice Valve Flanged end as per IS : 14846 Body, Cover - CI IS : 210, Gr. FG260 Door-CI IS:210, Gr. FG260 Body Ring-Bronze IS : 318 Gr. LTB2 Door Face-Natural Rubber Hinge Pin - SS ASTM A276 type 410 Fasteners - CS IS : 1367, CL -4.6/4.0 Gasket-Natural Rubber Flange Drilling - IS : 1538, Table 4 & 6 54 300 mm dia. 55 600 mm dia. 56 Supply, Installation Testing & Commissioning Traveling crane supply of 10 Ton Capacity, Span of6 m,12 m traveling crane standard make capacity block extra with required material (Indef/Morris or Equivalent make and should be relevant to IS/BS standard) complete in all respect with required civil work and complete in all respect. 1 . Type - Single Girder Crane for indoor application. 2. Type of Application - The Pump house. 3. Class of Duty -M5 as per IS 3177. 4. Standards - The crane to be Devid Manufactured and tested in accordance with the latest revisions & eshitions of IS IT IS 3177 and other relics ani pode and standards in medicured under Paragraph 5.0. 5. Location - Indoor. 6. Capacity SWL - 10 Tonnes. 7. Height of track rail - 5.9 Mtr above floor level (refer sketch) 8. Span - 9 Mtr. 10. Clearance height above the gantry rail - 1100 mm. 11. Cross trave of Crane - 9 Mtr. 12. Speeds, hoisting/lovering - 266 m/min (approximately), Cross travel - 17.0 m/min (approximately), Long Travel - 20.0 m/min (approximately), 13. Bridge Girder - Bridge girder shall be RSJ type with rubber bullet Indian Standard hot rolled structura sections as per 808-1957 IS 1173- 1957 IS 1864-1963 IS 800-1962 IS 816 1956 Garder should the strong and rugged to withstand the most severe condonatios of loads/swester diferent working conditions The Bridge Girder shall be designed to love maximum deflectim of span 900 at SWL in order to have better structural indegrity Sufficunt space shall be provided for ease of maininanis. 14. End Carriage - Fabricated out of MS Plate or C Channel of saitabile size to farm box except for essential openings which should be renforced. End camages se be fitted with substantial safety stops to prevent the crane from falling and should not lnterfere with removal of wheel. 15. - - . 16. Cross travel and Long travel wheel - 0.75 KW 2 drive for LT motor and 0.55 KW 2 drive for CT motor LT Wheels shall be Double Flanged and CT Wheels Single Flanged of EN 9 nutinal. The item should be machined and hardened to required hardness. The wheals to be mounted on anninction bearings and shall 57 Supply, Installation Testing & Commissioning. 300 mm dia. MS rising mains of 6 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. deep into the underground trench excavated in the existing road etc all comp. as per direction of E/inch. as per the unit rate analysis. 58 Supply, Installation Testing & Commissioning. 600 mm Dia MS rising mains of 6 mm wall thickness including coupling and laying for discharge of the storm of the pumping plant including excavation laying of the pipe etc. 1.0 to 1.50 Mtr. Deep into the underground trench excavated in the existing road etc all comp.with required civil work and complete in all respect 59 Supply, Installation Testing & Commissioning of 400 KVA DG Set , Alternator Water Cooled with Standard Panel, Acoustic Enclosure and Base Framewith required civil work and complete in all respect complying latest Centralpollution Control BoardGuidlines (CPCB-IV) MAKE KIRLOSKER/STERLING/MAHINDRA/EQV. 60 Supply, Installation Testing & Commissioning of 630 kva CSS transformer complete in all respect.Particulars MAKE PVJ/ABC/EQV.(a) Designation (b) Transformer Location - Out Door(c) Degree of protection - IP -55(as per IS :2147)(d) Rated output -01 No500 KVA(e) No load transformation ration11/0.433 KVA - 1 No(f) Number of Phase - Three(g) Rated frequency - 50 Hz.(h) Number of windings/(i) Method of Connection(ii) HV winding - Delta(iii) LV winding - Star(i) Vector group - DYN - II(j) Impulse (peak)(k) Power frequency(Dry and wet)(l) Bushing(i) Voltage ClassesHV LineLV Line(ii) Impulse(iii) Power Frequency with stand HVLVHT VCB/Panel for 500 KVA CSS transformer complete in all respect.Particulars(a)11kv 800A 26.3KA HT VCB (b) Overcurrent & earth fault relay(c) Master Trip Relay (d) TRIP CIRCUIT SUPERVISION RELAY(e) Three Phase ammeter, Acc. CI::1.0(f) Three Phase voltmeter, Acc. CI::1.0(g) Multifunction meter(h)Fixed type Voltage Transformer 100VA/v3/110V/3(i) Current trasnformer resin cast dual core(j) 20A fuse base for bolted type fuse link, Size :F1(k) 6A off set clip in type HRC fuse link, Size:F1(l) 6A 1P 10KA, C-curve MCB(m) Auxilary Relay(n) Indicating light(o) Panel led lamp 150 mm(p) Door limit switch(q) Space heater 100W/230V(r) Thermostat(s) TNC 25A (t) Control terminal Block(u) Power Pack230V AC-24VDC 7AH(v) Emergency push button with NC Element 61 Supply, Installation, Testing & Commissioning of MS Work Specify as per site requirment and MS Manual Screen. 62 UNDER GROUND CABLESSupplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. or as per design requirement 63 240 Sqmm 3.5 Core 64 120 Sqmm 3.5 Core 65 Supply and burring of safe Earthing electrode pf T-39 Cu Copper coated, Length up to 3000mm, outer pipe 76.03 x 3.2 inner pipe 42.4 mm x 2.6 mm, terminal Dia 12mm, coating 80- 100 micro filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs active soil (BFC) capable of reducing the soil restively with good mixture of retaining capacity along with 30 CM square CI Frame with hinged cover & masonry housing. (from electrode terminal to switch board cost of 25x3 copper strip will be extra. 66 11 KV Work 67 Supply/fabrication and Erectionof 11 KV Double Pole Cable Exposure D/C complete with 410 SP-55 11 mtr long ST Pole-2 Nos, 11 kv pin insulator with pin and nut-9 nos, top channel 100x50 mm, MS angle 65x65x6mm, LT XLPE cable AL. 1x240sqmm-18mtr, danger board with clamp-2 nos, barbed wire, pole fencing-2 nos, aluminium lug- 12 nos, holding MS clamps-12 nos, nut bolts etc icluding painting of pole with aluminium paint over red oxide primer all complete as per UPPCL specification 68 SE of 11 KV TPMO switches on poles including handle rod etc. complete in all respects as approved by EI. (Previous Sanction Rate) (PS Rate) 69 SE of 11 KV D.O. fuse set on poles complete in all respects as per approval of EI. (Previous Sanction Rate) (PS Rate) 70 Supply and Laying of 80 mm dia G.I. pipe for the purpose of cable on the run pole through this G.I. pipe from level as cable carrier pipe should be tied with 2Nos. 50x6mm flat iron clamp with pole as per direction of E/I 71 Supply and laying of185 sq. mm 3 core standered aluminium conductor XLPE(Cross linked polyethylene)insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connectedwith earth conductor by clamps etc. (Supply Rs 1045 + Laying Rs. 910 = Rs. 1955 ) 72 supplying and making 185 sqmm3 Core outdoor cable end termination with heatshrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required all complite as per direction of E/Ic. 73 Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 74 S/FofLEDStreetLightFittingwithmandatorydriversethavingdiecastaluminium body and lenses suitable for 140 to 150 watt. Confirming to IP 66 protection having company LOGO engraved complete in all respect including labour as per direction of E/I.SI.No. 1425/2018Cat-AAA.15400-16500system lumensHigh PowerLEDwith Lenses,>1101m/W,PF<0.95THD<10%atfullload,CRI>70,Potteddriverset(Not Circuitory) Phase to Phase Protection at 440V & > 300V auto cut and re-start feature, with 5 years warrantee. Proper completion of work as per direction of E/I - CAT-AAA 75 PART-C (E/M WORK) 76 Operation & Maintanance On Part-B 77 Operation of Part-A 1st Year (0.5 % on Part-B) 78 Operation and Maintanance of Part-A 2nd Year (1 % on Part-B) 79 Operation and Maintanance of Part-A 3rd Year (1.25 % on Part-B) 80 Operation and Maintanance of Part-A 4th Year (1.5 % on Part-B) 81 Operation and Maintanance of Part-A 5th Year (2 % on Part-B)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
33.
Drinking Water Supply and Sanitation #9470718 Technical Bid
Tender For Bilari Nagar Palika Parishad Reorganization Water Supply Scheme Under Amrut 2.0 Programme - Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.All Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456.The steel for RCC shall be epoxy coated TMT bars- Fe 500/415 as per IS code IS 2062:2011.Minimum depth of foundation below original ground level will be 2.0 M.Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The assumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC platform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one aluminium ladder inside the tank body ( from manhole in top dome to bottom dome).1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali.Electro Magnetic Flow MeterLightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixed at top dome at proper place. 2 Supply, fixing, jointing of following size of D.I. D/F Pipes with D.I. D/F specials conforming to IS 8329/2000as vertical pipes for inlet, outlet, over flow and washout as per latest / relevent I.S. specifications with all jointing materials for proper completion of work including other appurtenant works and excavation in all types of soil. Zone-3:- Inlet 200 mm 200 mm Outlet 300 mm, Over flow 200mm & Wash out 100 mm. Zone-4:- Inlet 150 mm & 150 mm Outlet 300 mm, Over flow 150mm & Wash out 100 mm.Supply and Fixing of following sizes D.I. D/F sluice valves with hand wheels as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete.Zone-3:- Inlet 200 mm & 200 mm Outlet 300 mm & Wash out 100 mmZone-4:- Inlet 150 mm & 150 mm Outlet 300 mm & Wash out 100 mmConstruction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil.Construction of surface box type Sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement.Construction of washout/ overflow chamber as per departmental type design and drawing.Construction of P. C. C. Floor & Drain and all other necessary work as per departmental type drawing and design.Painting of all concrete surface and steel pipe worrks with three coats of approved cement paint and anticorrosive paints.Testing & Commission etc. all complete work.Testing and submission of test report of bearing capacity of soil from a recognized Govt. institute.Submission of 5 sets of detailed design and drawing of O.H.T and mix design of M30 concrete done and vetted by Head of the department from any IITs/Central University as per direction of Engineer-in -charge. The design of tank & foundation will be based upon the soil investigation report which shall be done from any Govt. institute. 3 1700 KL / 18.0 M Staging (ZONE-03) 4 500 KL / 18.0 M Staging (ZONE-04) 5 RISING MAINSupply of the following sizes of D.I. pipes Class K-9 conforming to latest I.S. 8329/2000 andD.I. S/S or flanged Specials conforming to I.S. 8329/2000 Suitable for above C.I.S/S pipe F.O.R destinationfrom tubewell to OHT including bypass including all Taxes and insurance. complete in all respect. 6 150 mm dia K-9 7 200mm dia K-9 8 Excavation for DIpipe line trenches in ordinary soil,(lime, clay or sand including lift up to 1.5m and lead up To 50m and refilling, watering, ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the centre of the foundation trenches. 9 Carting from the store (up to 8 Km.) The following sizes of D.I. double K-9 pipeand specials to the site of work lowering them into trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. complete but excluding cost of trenching and cutting of pipes etc. For making of lengths but including making joints. 10 150 mm dia K-9 11 200mm dia K-9 12 Supply of all materials, labour, T & P etc. required and construct thrust blocks at the bends and below the Valves. 13 DISTRIBUTION SYSTEMSupply of the following sizes of DI K-7 & HDPE pipes(PN-6, PE-100) confirming to latest relevant I.S.Codes with DI/HDPE Specials conforming to I.S.- 8329/2000 and I.S.- 4984/2016 respectively etc complete in all respect F.O.R. destination including all taxes and insurance. 14 450 mm dia DI K-7 15 400 mm dia DI K-7 16 350 mm dia DI K-7 17 300 mm dia DI K-7 18 250 mm dia DI K-7 19 200 mm dia DI K-7 20 160 mm dia HDPE PN-6/PE100 21 140 mm dia HDPE PN-6/PE100 22 125 mm dia HDPE PN-6/PE100 23 110 mm dia HDPE PN-6/PE100 24 90 mm dia HDPE PN-6/PE100 25 Supply of the following sizes of Hand Wheel operated with Sluice Valves destination including all taxes and insurance. 26 350 mm dia 27 300 mm dia 28 250 mm dia 29 150 mm dia 30 125 mm dia 31 100 mm dia 32 80 mm dia 33 Supply of the following sizes of C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including all taxes and insurance. (80mm dia) 34 Supply of 25 mm dia screwed down type air valve with gun metal seat at site stone including all taxes. 35 Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia duck foot bend and 63 mm dia standard make iron coupling with cap and chain etc. complete to ISS 909 at site including all taxes. 36 Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches. 37 Dismantlingof following type of surface including all layers, sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. 38 B.O.E. ROAD 39 BITUMINOUS ROAD 40 C.C. ROAD 41 INTERLOCKING TILES ROAD 42 Reinstatement of following type of road surface. 43 B.O.E. Road with 40% new bricks and 60%used old bricks over 30mm compacted local sand including all materials,labour,T&P etc complete 44 Bituminous Roads with granule sub base (G1-100mm, G2-75mm, G3-75mm thick),50mm thick bituminous macadam over priming coat and tack coat and 30mm thick SDBC/BC over tack coat & disposal of all debris and surplus earthwithin8 Km. distance as per direction of Engineer-in-charge, including all materials,labour,T&P etc complete 45 C.C. Road will be prepared with 10 cm thick P.C.C. 1:2:4 Cement: Coarse Sand & 20 mm Stone grit over base concrete 15 cm. P.C.C. 1:4:8 with cement coarse sand & 40 mm stone ballast after compacting the earth surface properly. The C.C. surface must be compacted with surface vibrator, including all materials,labour,T&P etc complete. 46 Interlocking Tile road:Tiles must be of the thickness & grade similar to that of the dismantled tiles over base concrete 75 mm thick PCC 1:4:8 cement: local sand: stone ballast as per existing road. The thickness of tiles shall be same as that of existing road, including all materials,labour,T&P etc complete. 47 Carting from the store (up to 8 Km.) the following sizes ofD.I & HDPE pipe and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. complete but excluding cost of trenching but including making joints. 48 450 mm dia DI K-7 49 400 mm dia DI K-7 50 350 mm dia DI K-7 51 300 mm dia DI K-7 52 250 mm dia DI K-7 53 200 mm dia DI K-7 54 160 mm dia HDPE PN-6/PE100 55 140 mm dia HDPE PN-6/PE100 56 125 mm dia HDPE PN-6/PE100 57 110 mm dia HDPE PN-6/PE100 58 90 mm dia HDPE PN-6/PE100 59 Carting of D/F Sluice valves of Following sizes to the site of worksLowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding valve and specials Required but including the testing etc. complete 60 350 mm dia 61 300 mm dia 62 250 mm dia 63 150 mm dia 64 125 mm dia 65 100 mm dia 66 80 mm dia 67 Carting of 80 mm dia scour valves to the site of workslowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding valves and specials Required but including the testing etc. complete. 68 Carting of 25 mm dia screwed down air valves to the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding valves and specials Required but including the testing etc. complete 69 Carting of 80 mm dia flanges fire hydrant to the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding valves and specials Required but including the testing etc. complete. 70 Supply of all materials, labour T&P etc. required and construct surface box/masonry type sluice / scour valve chamber as per type design including supply and materials labour, T&P etc. complete. 71 Surface box type 72 Masonry type 73 Supply of all materials, labour T&P Etc. required and construct 350 x 350 x 500 mm size air valve chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 74 Supply of all materials, labour T&P Etc. required and construct 750 x 750 x 1000 mm size fire hydrant chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 75 Provision for Large crossing of nala,raod & culverts including shifting of telephone cable etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and iointing testing etc,complete.(FOR 7.0 M WIDE) 76 Provision for Small crossing of nala,raod & culverts including shifting of telephone cable etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and jiointing testing etc,complete.(FOR 3.5 M WIDE) 77 Pump House cumchlorinating room(3.60x3.0x3.0)m and (2.5 x 1.8x 3.00)m 78 Excavation of earth in ordinary soil (loam clay or and) including lift upto 1.5 m and lead upto 50 m.filling, watering and ramming of excavated earth in between the building and sides of the foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50 m from the center of the foundation trenches. 79 Concrete with 40 mm gauge Ist class brick ballast, coarse sand and cement in proportion (8:4:1) in foundation including supply of all materials, labour,T&P etc required for proper completion of work. 80 Ist class brick work in 1:6 cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour,T&P etc required for proper completion of work. 81 150 mm thick RCC plinth bend With cement and approved coarse sand with 20 mm stone grit 1 :1.5:3 including supply of 5% water proofing material, labour, T&P etc required for proper completion of work. 82 Ist class brick work in 1:6 cement and Coarse sand mortar in super structure including supply of all materials, labour,T&P etc required for proper completion of work. 83 M.S. Angle iron chaukhat of 40mm x 40mm size supply and fixing including simple moulding straight work as in chaukhat and also supply of all material, labour, T&P etc. required for proper completion of the work. 84 Supply and fixing of 1mm thick sheet iron panelled door, windows shutter including supply and fixing and adjustment of hinges , bolts, locks, handles, springs and other fittings but excluding supply and painting of fittings. 85 Supply and fixing of hold fast in doors and windows of size 25cm x 4cm x 9mm flat iron including their cutting and moulding and welding to required shape also including other material such as nails and screws etc. required for proper completion of the work. 86 R.C.C. Work cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.5 mm thick binding wire (to be supply by the contractor) centering and shuttering supply of all materials, labour,T&P etc required for proper completion of work. 87 R.C.C in sun shade with cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 including supply of reinforcement and it bending and including its fixing and bindingits fixing in position with centering, curing supply of all materials, labour,T&P etc required for proper completion of work. 88 R.C.C in lintel with cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 including supply of reinforcement and it bending and including its fixing and bindingits fixing in position with centering, curing, supply of all materials, labour,T&P etc required for proper completion of work. 89 R.C.C in slab with cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 including supply of reinforcement and it bending and including its fixing and bindingits fixing in position with centering, curing, supply of all materials, labour,T&P etc required for proper completion of work. 90 Mild steel or Iron work in plain work such asR.C.C. Work wrought to required shape as necessary including its bending and supply of steel,wastage, over lapping and hooks etc complete required for proper completion of work. 91 Mild steel gril in windows, wrought to required heavy/ small size form including supply of all materials,labour,T&P etc. Required for proper completion of the work. 92 Supply and lay complete 40 mm thick insulation layer of sand and clay over reinforcement brick or cement concrete. 93 Providing & lying of Brick Coba 12mm thick laid with M-150 class brick bat Coba 7.50 cm thick with gap of 15mm to each (As per PWD specification) including supply of all materials , labour T&P etc. required for proper completion of the work. 94 12 mm thick plaster with cement coarse sand mortar in 1:6 (over brick work with 3 mm floating coat of neat cement including supply of all materials, labour,T&P etc required for proper completion of work. From GL upto super structure. 95 12 mm thick plaster with cement coarse sand mortar in 1:4 (over brick work with 3 mm floating coat of neat cement including supply of all materials, labour,T&P etc required for proper completion of work on ceiling. 96 40 mm thick 1:2:4 plan cement concretefloor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cement,4 part of coarse sand and 8 part ist class brick ballast 40 cm gauge(1:4:8) and removing any over lapping of mortar at the joist of panel if any and giving them uniform finished including supplymaterial, labour,T&P etc required for proper completion of work. 97 Supply and fix 32 mm thick Flush door shutter including supply and fixing and adjustment of hinges,bolt,locks,handles,spring and other fittings but excluding painting and supply of fitting. 98 Same as above but windows shutters. 99 Supply and fixing of oxidised iron fitting of approved make for doors and windows. 100 Painting and varnishing of new iron work with one coat priming and two coat of approved paint and varnish including supply of all materials, labour, T&P etc required for proper completion of work. 101 White washing in one coat including supply of all materials, labour, T&P etc required proper completion of work. 102 Providing wall putty on new surface with approvel quality material of Berger/J.K./Birla or similar make 2 coates. 103 Finishing wall with one coat of water proof cementpaint. Weather coat of approved quality on previously new surface with this paint to give an even shade including supply of all marerials, labour, Tools & plant etc. required for proper completion of the work. 104 Same as above but over previously painted surface weather coat. 105 Provide and fixed RCC precast Jalies of 30 cm x 60 cm size including supply of all materials, labour, T&P etc required proper completion of work. 106 Supply and fixing of rolled steel Joist 150 mm x 100 mm including its painting with approved paint and also one coat of primer. 107 Cartage & cost of earth work in filling in plinth including supply of excavated earth from distance of eight km. 108 Supply of all materials, labour, T&P etc. required for construction of 250 mm dia S.C. Drain. 109 Supply of all materials, labour, T&P etc. required for the construction of stilling / Byepass chamber V notch chamber including supply of V notch etc. all complete. 110 Rain water down pipe 100 mm dia PVC with fixed MS clamp etc including supply of all materials, labour, T&P etc required proper completion of work. 111 Boundary WallConstruction of Boundary wall 0.23 m thick and 1.5 m height above plinth level with all materials, labour T&P etc. required for proper completion of work. 112 Construction of pillars as per type design including fixing of gate 3.6 m wide gate and 1.2 m wide wicket gate with all materials, labour T&P etc. required for proper completion of work. 113 Construction of interlocking tile road with 80 mm thick M-30 grade tile over base concrete 75mm thick PCC 1:4:8, cement:local sand:stone ballastfor approach road & water works campus with all materials, labour T&P etc. required for proper completion of work. 114 Provision for inside square drain including supply of all materials labour and T & P etc. complete. 115 Repairing of Existing Building Works (Staff Quarter, Pump House & Boundary Wall) 116 Ist class brick work in 1:6 cement and Coarse sand mortar in super structure, supply of all materials, labour,T&P etc required for proper completion of work.(Old Water Works Campus) 117 12mm thick plaster with cement and coarse sand mortar in 1:6 over existing brick work minimum thickness not to be less than 12mm including supply of all materials, labour, T&P etc. required for proper completion of the work. 118 Supply & fixing of all materials, labours, T&P etc. required for making door shutters by M.S sheet 18mm gauge including supply and fixing M.S 40x40x6 mm size also including angle iron chaukhat supply & fixing of oxidized iron fittings etc. complete. 119 Painting and varnishing all iron work one coat priming and two coat of approved paint oe varnish including supply of all material, labour, T&P etc. required for proper completion of the work 120 weather coats with approved coloring including supply of all material, labour, T&P etc. required for proper completion of the work 121 40 mm thick 1:2:4 plan cement concretefloor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cement,4 part of coarse sand and 8 part Ist class brick ballast 40 cm gauge(1:4:8) and removing any over lapping of mortar at the joist of panel if any and giving them uniform finished including supplymaterial, labour,T&P etc required for proper completion of work. 122 White washing in three coats including supply of all materials, labour, T&P etc required proper completion of work. 123 Making ferrule connection of various nominal dia of new distribution mains in different type of roads with fixing of saddle piece, service connections, fittings, and fixing of brass ferrule of 15mm size includingtapping the main. Include the cost of excavation and subsequent backfill of trenchs and cost of fittings and specials, including labour charges for cutting, threading &fitting of GI pipe and specials including supply of binding materialssuch as safeda and teflon tape etc.Including making hole in the wall for crossing of GI pipe also repairing the same with mortar and also including crossing of drain with all labour T&Petc. complete. including material i.e.3 meter 20mm dia (OD) HDPE Pipe (12.5 kg/cm2), 2 meter 20mm (OD)GI pipe Class-B, EL-bow 20mm (OD) GI for above pipe Class -B, Clamp with Saddle, TAP/Stop Cock (Brass) 15mm, Ferrule brass HDPE 15mm with end cap (heavy duty),20 mm dia PP-Adopter and 20 mm dia GI - Union. 124 FOR BOE ROAD 125 For 90mmto 110mm dia 126 For 125mm to 160mm dia 127 For 180mm to 250mm dia 128 For 300mm dia 129 For 350mm to 500mm dia 130 FOR CC ROAD 131 For 90mmto 110mm dia 132 For 125mm to 160mm dia 133 For 180mm to 250mm dia 134 For 300mm dia 135 For 350mm to 500mm dia 136 FOR BITUMINOUS ROAD 137 For 90mmto 110mm dia 138 For 125mm to 160mm dia 139 For 180mm to 250mm dia 140 For 300mm dia 141 For 350mm to 500mm dia 142 FOR INTERLOCKING TILES ROAD 143 For 90mmto 110mm dia 144 For 125mm to 160mm dia 145 For 180mm to 250mm dia 146 For 300mm dia 147 For 350mm to 500mm dia 148 FOR KACHHA ROAD 149 For 90mmto 110mm dia 150 For 125mm to 160mm dia 151 For 180mm to 250mm dia 152 For 300mm dia 153 For 350mm to 500mm dia 154 Variation in 20 mm (OD) dia HDPE Pipe w.r.t 3.0 mtr 155 Variation in 20 mm (OD) dia GI Pipe w.r.t 2.0 mtr 156 Construction of LCS/MCS Room 157 Excavation of earth in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50m and lead upto 50m and refilling, watering, ramming of excavated earth into the space between the building and sides of foundation trenches or into the plinth and disposal of surplus earth upto the distance of 50m from the center of the foundation trenches. 158 Cement concrete with 10-12mm gauge approved stone ballast, coarse sand and cement in proportion of 1:1½:3 including supply of all materials, labour, T&P etc. required for proper completion of the work by hand for column 350mm dia 5m high including floor beam and floor slab. 159 First class brick work with cement coarse sand in proportion 1:3 in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. 160 Same as above but in super structure 4.5m high. 161 20mm thick damp proof coarse sand with cement and approved coarse sand 1:2 including waterproofing materials or in the proportion as specified by the manufacturers including supply of all materials, labour, T&P etc. required for proper completion of the work. 162 R.C.C. work with cement, coarse and 20mm gauge approved stone ballast in proportion 1:1½:3 in slab and wall etc. excluding supply of reinforcement and its bending (but including its fixing and binding the same with 0.50 mmthick binding wire) shuttering, centering and supply of all materials, labours T&P etc. required for proper completion of work. 163 * Lintel and sunshades 164 * Slab 165 Providing form work including centering, shuttering and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in situ reinforced concrete and plain concrete work in walls. 166 Mild Steel or iron work in plain work such as reinforced concrete brick work (when not including in all over rates) brought to required shape as necessary including bending and cutting for proper completion of workincluding supply of steel and its wastage. 167 12mm thick plaster with cement and coarse sand mortar in 1:4 over brick work including supply of all materials, labour T&P etc. complete. 168 White wash in one coat including supply all materials, labour, T&P etc. complete. 169 Providing wall putty on new surface with approvel quality material of Berger/J.K./Birla or similar make 2 coates. 170 Finishing wall with one coat of water proof cementpaint. Weather coat of approved quality on previously new surface with this paint to give an even shade including supply of all marerials, labour, Tools & plant etc. required for proper completion of the work. 171 Same as above but over previously painted surface weather coat. 172 Supply and fixing 40 mm thick C.P. Teak wood all paneled door and window shutter including supply and fixing of wooden cleat and stops and fitting but exculding their supply and including painting with the two coats of black Japan on all iron fitting of necessary and including fixing the glass pane with putty and board glass to be 0.6Kg. fitting with necessary screen for to be supplied by department. 173 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with that iron diagonal 20x5mm size with top and bottom rails of iron 40x40x6mm with 38mm dia steel pulley with bolts, nuts locking arrangements stopppers, supply and painting one coat of approved red lead paint. 174 Providing and fixing in position rolling shutters of approved make of 80x125mm gauge called rolled M.S. lotha interlocked throughout their entire length and jointed together at the end by end locks and mounted on specially designed pipe shaft with branches shade girder and arrangement for inside and outside locking with push and pull operation complete but excluding the cost of top cover and spring. 175 Mild steel or iron work in small size and section such as holding down bolts, holdfasts, tie rods, grating (when not included in all over al rates) wrought to required terms including suppply of steel bolts and wastage etc. their fixing. 176 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Kms. From site of work and including watering, dressing etc. complete. 177 Supply and fixing of exhaust fan including supply of all materials, labour, T&P etc. required for proper completion of the work. 178 Supply and fixing of 150 mm, S.W. drain pipe including supply of all materials, labour, T&P etc. required for proper completion of the work. 179 Supply and fixing of 150mm dia A.C. pipe for comb including supply of all materials, labour, T&P etc. required for proper completion of the work. 180 Staff Quarter 181 Excavation of earth in ordinary soil (loam clay or and) including lift upto 1.5 m and lead upto 50 m.filling, watering and ramming of excavated earth in between the building and sides of the foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50 m from the center of the foundation trenches. 182 Concrete with 40 mm gauge Ist class brick ballast,localsand and cement in proportion (8:4:1) in foundation including supply of all materials, labour,T&P etc required for proper compltion of work. 183 Ist class brik work in 1:6 cement and local sand mortar in foundation and plinth including supply of all materials, labour,T&P etc required for proper compltion of work. 184 150 mm thick RCC plinth bend With cement and approved coarse sand with 20 mmm stone gritt 1 :1.5:3 including supply of 5% water proofing material, labour, T&P etc required for proper completion of work. 185 Same as item no 3 but in super structure for wall up to 1 brick thick) 186 Supply and fix 32 mm thick Flush door shutter on doors and window including supply and fixing and adjustment of hinges,bolt,locks,handles,spring and other fittings but excluding painting and supply of fitting. 187 R.C.C. Work cement,coarse sand and 20 mm gauge approved stone ballast in proper ratio of 1:1.5:3 excluding supply of reinforcement and it bending but including its fixing and binding the same with 0.5 mm thick binding wire (to be supply by the contractor) centering nd shuttering supply of all materials, labour,T&P etc required for proper compltion of work. 188 Mild steel or Iron work in plain work such asR.C.C. Work wrough to required shape as necessary including its bending and supply of steel,wastage, over lapping and hooks etc complete required for proper completion of work. 189 12 mm thick plaster with cement local sand mortar in 1:4 (over brick work with 3 mm floating coat of neat cement including supply of all materials, labour,T&P etc required for proper compltion of work. From GL upto supper structure. 190 Same as above but in proprtion 1:4 with cement and fine sand mortar on ceiling 191 40 mm thick 1:2:4 plan cement concretefloor with cement,coarse sand and 20 mm gauge approved stone ballast laid in penel finished with 3 mm loating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part ist class brick ballast 4 cm gauge(1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supplymaterial, labour,T&P etc required for proper compltion of work. 192 Same as above but base concrete of 1:4:8 in cement , local sand and 40mm gauge first class brick ballast etc complete. 193 B.O.E. Flooring in 1:6 cement mortar over 75 mm thick brick ballast base concrete (1:4:8) and surface painted with 1:2 in court Yard. including supplymaterial, labour,T&P etc required for proper compltion of work. 194 Painting and varnishing of new iron work with one coat priming and two coat of approved paint and varnish including supply of all materials, labour, T&P etc required for proper completion of work. 195 White washing in one coat including supply of all materials, labour, T&P etc required proper completion of work. 196 Providing wall putty on new surface with approvel quality material of Berger/J.K./Birla or similar make 2 coates. 197 Finishing wall with one coat of water proof cementpaint. Weather coat of approved quality on previously new surface with this paint to give an even shade including supply of all marerials, labour, Tools & plant etc. required for proper completion of the work. 198 Same as above but over previously painted surface weather coat. 199 Rain water down pipe 100 mm dia PVC with fixed MS clamp etc including supply of all materials, labour, T&P etc required proper completion of work. 200 Mild steel gril in windows, wrought to required form including supply of all materials,labour,T&P etc. Required for proper completion of the work. 201 Construction of semi circular drain 200 mm dia including supply of all material, labour, T&P etc. complete. 202 Electrification work complete. 203 Sanitation workWater supply work complete. 204 CONSTRUCTION OF TUBEWELL (300x200mm dia) for Zone-3 205 Transportation, Erection, Dismantling of Rig Machine and its T&P 206 Transportation, Erection, Dismantling of Compressor 250/350 PSI 207 Transportation, Erection, Dismantling of 2 Cusec/ 3 Cusec O.P. Unit and Yield test 208 Supply of Tubewell AssemblyM.S.Tubewell assembly with all required parts like plain pipe, Slotted pipe (as required upto 50% of plain pipes) rings, well cap bail plug, clamp reducer, central guide, suport structure etc. as required & as per typed design complete in all respect. (Note- Axial Length of Reducer without Ring shall be measured with casing pipe) 209 300 mm dia M.S. Pipe 210 200 mm dia M.S. Plain/slotted 211 PEA-GRAVEL (As per IS:4097)1.65 mm to 4.50 mm size Pea gravel of Lalkuwan quarry duly screened, washed and properly stacked at sitefor Tubewell 212 Drilling of bore by rig machine As Per IS:2800(Part I & II): 213 Drilling of bore by 600 mm dia bit GL to 45 mt. BGL. 214 Drilling of bore by 500 mm dia bit from 45 mt GL to 100 mt. BGL. 215 Drilling of bore by 500 mm dia bit 100 m BGL to 140 m. BGL. 216 Lowering of tube well assembly With M.S. rings, Bail Plug, Reducer Including welding: 217 Lowering of 300 mm dia M.S. Housing pipe from GL to 42 m.BGL 218 Lowering of 200 mm dia M.S. Plain/slotted pipe 42 m. BGL to 100 m. BGL 219 Lowering of 200 mm dia M.S. Plain/slotted pipe 100 m. BGL to 126 m. BGL 220 Development of tube well by 250 PSI air compressor and 2/3 cusec O.P. Unit to yield sand free discharge. 221 Development and testing of tube well by Air Compressor. 222 Development and testing of tube Well O.P.Unit to yield sand free Discharge. 223 Chemical and Bacteriologicaltest (Analysis of water sample) 224 Logging of borehole by departmental/approved electric logger 225 CONSTRUCTION OF TUBEWELL (300x150mm dia) for Zone-4 226 Transportation, Erection, Dismantling of Rig Machine and its T&P 227 Transportation, Erection, Dismantling of Compressor 250/350 PSI 228 Transportation, Erection, Dismantling of 1 Cusec/ 3 Cusec O.P. Unit and Yield test 229 Supply of Tubewell AssemblyM.S.Tubewell assembly with all required parts like plain pipe, Slotted pipe (as required upto 50% of plain pipes) rings, well cap bail plug, clamp reducer, central guide, suport structure etc. as required & as per typed design complete in all respect. (Note- Axial Length of Reducer without Ring shall be measured with casing pipe) 230 300 mm dia M.S. Pipe 231 150 mm dia M.S. Plain/slotted 232 PEA-GRAVEL (As per IS:4097)1.65 mm to 4.50 mm size Pea gravel of Lalkuwan quarry duly screened, washed and properly stacked at sitefor Tubewell 233 Drilling of bore by rig machine As Per IS:2800(Part I & II): 234 Drilling of bore by 600 mm dia bit GL to 48 mt. BGL. 235 Drilling of bore by 500 mm dia bit from 48 mt GL to 100 mt. BGL. 236 Drilling of bore by 500 mm dia bit 100 m BGL to 140 m. BGL. 237 Lowering of tube well assembly With M.S. rings, Bail Plug, Reducer Including welding: 238 Lowering of 300 mm dia M.S. Housing pipe from GL to 42 m.BGL 239 Lowering of 200 mm dia M.S. Plain/slotted pipe 42 m. BGL to 100 m. BGL 240 Lowering of 200 mm dia M.S. Plain/slotted pipe 100 m. BGL to 126 m. BGL 241 Development of tube well by 250 PSI air compressor and 2/3 cusec O.P. Unit to yield sand free discharge. 242 Development and testing of tube well by Air Compressor. 243 Development and testing of tube Well O.P.Unit to yield sand free Discharge. 244 Chemical and Bacteriologicaltest (Analysis of water sample) 245 Logging of borehole by departmental/approved electric logger 246 PUMPING PLANT AND Voltage STABILIZER for Zone -3 247 Supply, Installation, testing and Commissioning of 2000 lpm , 55 mtr Head Pumping Plant including 24 met coloumn pipe, NRV,CI D/F Bend 90 deg., CI A/F Tee, D/F pipe (1.5 met long-2 Nos and 1 met long- 1 No ), Earthing, Painting,Toolset, wiring of pump house (with internal&external electrification),chainpully block and all pumping plant accessories with nut bolts and rubber packing etc. 248 SITC of 150 mm dia size motor operated actuators with metal sheeted sluice valves 249 SITC of Soft starter for above 40 HP pumpset with RS 485 Port-400V Class for above pumpset 250 SITC of 60 kva stabilizer for above pumpset 251 SITC of equipments for the items as given below : 252 Pressure transmitter 253 Misc. Items such as Protection Ring, Cutout, Electric resistance Rubber sheet, Transformer oil etc.-2019 254 Coloumn Pipe 5 mtr long 255 SITC of NEW PUMPING PLANT & VOLTAGE STABILIZERfor Zone-4 256 Supply, Installation, testing and Commissioning of 600 lpm ,53 mtr Head Pumping Plant including 24 met coloumn pipe, NRV,CI D/F Bend 90 deg., CI A/F Tee, D/F pipe (1.5 met long-2 Nos and 1 met long- 1 No ), Earthing, Painting,Toolset,wiring of pump house (with internal&external electrification),chainpully block and all pumping plant accessories with nut bolts and rubber packing etc. 257 SITC of suitable capacity soft starter with RS485 port- 400 V Class. 258 SITC of 100 mm dia size motor operated actuators with metal sheeted sluice valves 259 SITC of 25 kva stabilizer for above 260 SITC of equipments for the items as given below : 261 Pressure transmitter 262 Misc. Items such as Prtection Ring, Cutout, Electric resistance Rubber sheet, Transformer oil etc.-Sor 2019 263 Coloumn Pipe 5 mtr long 264 SITC OFREQUIRED E&M WORK AS GIVEN AT EXISTING TUBEWELL OF ZONE-1 265 SITC of Soft starter for above pumpset with RS 485 Port-400V Class for above pumpset 266 CE/UL certifeid Actuator for existing valves 267 CE/UL Certifeid Electromagnetic Flow Meter of suitable size 268 SITC of suitable size stabilizer for above pumpset 269 Pressure transmitter 270 Internal electrification of pump house 271 SITC OFREQUIRED E&M WORK AT EXISTING TUBEWELL OF ZONE-2 272 SITC of Soft starter for above pumpset with RS 485 Port-400V Class for above pumpset 273 CE/UL certifeid Actuator for existing valves 274 CE/UL Certifeid Electromagnetic Flow Meter of suitable size 275 SITC of suitable size stabilizer for above pumpset 276 Pressure transmitter 277 Internal electrification of pump house 278 SITC OFREQUIRED E&M WORK AT EXISTING TUBEWELL OF ZONE-4 279 Supply, Installation, testing and Commissioning of 600 lpm ,53 mtr Head Pumping Plant including 24 met coloumn pipe, NRV,CI D/F Bend 90 deg., CI A/F Tee, D/F pipe (1.5 met long-2 Nos and 1 met long- 1 No ), Earthing, Painting,Toolset,wiring of pump house (with internal&external electrification),chainpully block and all pumping plant accessories with nut bolts and rubber packing etc. 280 SITC of Soft starter for above pumpset with RS 485 Port-400V Class for above pumpset 281 CE/UL certifeid Actuator with metal sheeted newvalves 282 CE/UL Certifeid Electromagnetic Flow Meter of suitable size 283 SITC of 25 kva stabilizer for above pumpset 284 Pressure transmitter 285 SITC OF SCADA /AUTOMATION WORK OF EXISTING PUMPING PLANTZONE-1,2 & 4 286 CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem unit with CPU and power supply with analog anddigital parameter and features as specifeid for tubewell to store and transmit data on GSm backbone RTU/PLC designed with logic to transfer data at multiple statiuonas specifeid. 287 GSM/GPRS based wireless communication with 4G modem for RTU/PLOc capable to transfer & gather data from remote site to controlstation all accessoreis included with signalenhancer antenna made for pumping plant internet charges as specifeid 288 CE/UL certifeid Intelligent Smart Energy Meter 289 auto Phase reversal unit of 250 amp rating with inbuilt delay and enclosure control panel etc. 290 CE/UL certifeid Surge Protecter for control panel. 291 CE/UL Certifeid 7 hmi touch screen suitable to communication with PLC/RTU for display & control of process parameters 292 Complete cabling including power cables of all equipment. 293 control panel with IP54 protection ,industrial grade for all equipments.separate for control (24V) and power equipment with capacitor bank panel to improve power factor. 294 Installation, commissioning & testing trial for tubewell 295 SITC OF SCADA /AUTOMATION WORK OF NEW PUMPING PLANTFOR ZONE 3 & 4 296 CE & UL Certifeid PLC/RTU in IP 54 enclousure suitable to communicate with GSM based modem unit with CPU and power supply with analog anddigital parameter and features as specifeid for tubewell to store and transmit data on GSm backbone RTU/PLC designed with logic to transfer data at multiple statiuonas specifeid. 297 GSM/GPRS based wireless communication with 4G modem for RTU/PLOc capable to transfer & gather data from remote site to controlstation all accessoreis included with signalenhancer antenna made for pumping plant internet charges as specifeid 298 CE/UL certifeid Intelligent Smart Energy Meter 299 CE/UL Certifeid Electromagnetic Flow Meter 150 mm size 300 CE/UL Certifeid Electromagnetic Flow Meter 100 mm size 301 auto Phase reversal unit of 250 amp rating with inbuilt delay and enclosure control panel etc. 302 CE/UL certifeid Surge Protecter for control panel. 303 CE/UL Certifeid 7 hmi touch screen suitable to communication with PLC/RTU for display & control of process parameters 304 Complete cabling including power cables of all equipment. 305 control panel with IP54 protection ,industrial grade for all equipments.separate for control (24V) and power equipment with capacitor bank panel to improve power factor. 306 Installation, commissioning & testing trial for tubewell 307 SITC OF AUTOMATIC CHLORINATION SYSTEM 308 Automatic Chlorination System compatible to SCADA system 309 SITC OFAUTOMATION SYSTEM AT EXISTING OHT FOR ZONE 1,2 & 4 310 CE/UL certifeid Radar Type level transmitter for OHT. 311 SITC of actuator for existing metal sheeted sluicevalve 312 CE/UL certifeid Electromagnetic Flowmeter forexistingOHT outlet pipe 313 Installation, commissioning & testing trial for OHT 314 SITC of UPS 3 kva 1phase suitable for operation of Actuators installed at outlet line in case of Power Failure at time of Distribution water supply 315 Lighting at Water works campus with solar panel and LED light of 1 set 316 SITC OFAUTOMATION SYSTEM AT NEW OHT FOR ZONE 3 317 CE/UL certifeid Radar Type level transmitter for OHT. 318 Actuator of 300 mm dia size with new metal sheeted sluicevalve 319 CE/UL certifeid Electromagnetic Flowmeter 300 mm size 320 Installation, commissioning & testing trial for OHT 321 SITC of UPS 10 kva 3phase suitable for operation of Actuators installed at outlet line in case of Power Failure at time of Distribution water supply 322 Lighting at Water works campus with solar panel and LED light of 1 set 323 SITC OF CHLORINE ANALYZER FOROHT FOR ZONE 1, 2,3&4 324 Supply, Installation, Testing & Commissioning of Chlorine analyser with MODBUS RTU as per given specification a) FRC sensors(range 0-5ppm)b) Analyzer with RS 485 O/P 325 TRIAL RUN OFTHREEMONTHS FOR ALL ZONE 326 Three months trial run of electro mechanical work with Expenditure on hypo chloride solution,Chaukidar, watch & ward etc for whole scheme 327 SITC OF ELECTRO MECHANICAL EQUIPMENTS ATLOCAL CONTROL STATION 328 CE/UL & BIS Certified industrial grade LARGE SIZE LED MONITOR with lates configuration as per specification. 329 Desktop/PC with i5/i7 processor for as per spec mentioned in tachnical bid documents. 330 CE/UL Certified 3 KVA UPS with batteries as perspec mentioned in tachnical bid documents.( 1 No.For LCS and 4 Nos for tubewells which are not constructed in OHT Campus) 331 Full development version of required TAGS SCADA Software with coustomization of software for LCS as per spec mentioned in tachnical bid documents. 332 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & receive data & gather data form remote sites to control station,All accessories include signal enhancer antenna along with running expences till DLP. 333 CE/UL certified Firewall for network protection. 334 Surge protector for eternet communication protection. 335 industrial grade Ethernet Switch. 336 canon/hp Laser printer1018 or equivalent 337 Installation,Commissioning ,testing including required furniture,internal wiring,PVC panelling of walls/false ceiling work and Split A/C . 338 Security Survelliance IP Camera with required hard drive to store data of atleast 15 Days 339 Trial run charges for LCS for 3 months
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
34.
Housing Urban and Rular Development #9456641 Technical Bid
Tender For Balance Work Tourist Facilitation Center At Lalapur District Chitrakoot (U.P.), 1 Balance Work Tourist Facilitation center at LalapurDistrict Chitrakoot (U.P.) 2 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour, tools and plants etc. required for proper completion of the works. 3 First Floor 4 Second Floor 5 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns(Concrete ofM-25 grade with minimum cement content of 330 kg /cum ) R.C.C. FOOTING 6 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete .R.C.C. columns(Concrete ofM-25 grade with minimum cement content of 330 kg /cum ) 7 First Floor 8 Second Floor 9 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) [M-20] 10 First Floor 11 Second Floor 12 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) [M-20] 13 First Floor 14 Second Floor 15 Same as in item no. 11 above but in super-structure above plinth level including necessary cutting and moulding of brick work as required & also including honey combed brick work in thickness of wall more than one brick and for extra labour to above items. 16 First Floor 17 Second Floor 18 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. Second Floor 19 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 20 Above Plinth Lvl. 21 Second Floor 22 15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth. 23 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chambers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand 24 Ground Floor 25 First Floor 26 Second Floor 27 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand 28 Ground Floor 29 First Floor 30 Second Floor 31 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 32 Ground & First Floor 33 Second Floor 34 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 35 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 36 Ground Floor 37 First Floor 38 Second Floor 39 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 40 Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 41 Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: 42 Supply and fixing 6 mm (1/4) thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. 43 Ground & First Floor 44 Second Floor 45 Providing and laying brick coba 100 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. 46 Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 35 mm thick. 47 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 48 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 49 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 50 Providing & fixing of door / windows grill. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding 51 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Angle iron chaukhat (40x40x5) 52 Fixing of Door, windows / ventilators chaukhats in position. 53 (a) Door chaukhats 54 (b) Window chaukhats 55 (c) Ventilator chaukhats 56 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profilesminus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm andsingle glass pane glazing beadof appropriate dimension.(Area of window upto 0.75 sqm.) 57 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 58 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 59 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles & rails will be mitred cut, joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturers specifications & direction of Engg.-in-charge. Non decorative finish 60 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections & other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia & size, including necessary filling up the gaps at junctions, i.e. at top, bottom & sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engg.-in-charge. (Glazing, paneling & dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) 61 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) 62 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm 63 Polishing in high gloss/matt finish melamine clear polish on woodwork in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no.and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finergrading with ample water to remove excess sealer layer andmake the surface further smooth after this wet rubbing, thensurface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete asper direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 64 Same as above but on new wood surface. 65 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 66 Ground Floor 67 First Floor 68 Second Floor 69 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent) 70 Ground Floor 71 First Floor 72 Second Floor 73 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 74 Ground Floor 75 First Floor 76 Second Floor 77 Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete.(a) 300mm x 16mm 78 P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc. 79 (a) 250 mm x 10mm 80 (b) 200 mm x 10mm 81 Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 125 mm 82 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 83 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar 84 Providing & fixing of Rolling shutters of approved design made of 80 x 125 mm (3 x 18 gauge) cold rolled MS lath interlocked throughout their entire length and jointed together at the end by end locks end mounted on specially designed pipe shaft with brackets, side guides & arrangements for inside and outside poking with push & pull operation complete but excluding the cost of top cover and spring. 85 Providing & fixing 27.5cm long wire spring grade No. 2 for rolling shutters. 86 Providing & fixing top cover for rolling shutters. 18 gauge. 87 Providing and fixing ball bearing for rollong shutters. 88 Providing & laying of light cinder filling under floor of toilets & other sunken roofs. 89 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 90 Construction of drain along with apron. 91 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK 92 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” 93 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 94 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 95 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 96 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 97 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 98 Supplying and installation of Extruded Aluminium linear facade and curves not exceeding 3000mm radius with 150X50mm block and 100mm space along with top and bottom cover and capping for individual profiles, fixed on extruded aluminum rail 80mmX50mm powder coated with dulux Eelctro black ace (or any specified shade) spanning between supports of maximum distance of 1500mm with the help of Sainless steel Non slip barb, steel rivet- galvanised to class 3, aluminium clip coated with external grade Matt powder coating, including the cost of necessary fittings and fixtures etc. as per approved drawing and design from Architect in charge (make Citadel/ Woodform Architectural or equivalent) 99 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone 100 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 101 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)Red sand stone - Exposed face machine cut and table rubbed with rough backing. 70 mm thick 102 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 103 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type. Fastener with threaded dia 10 mm 104 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 105 Centering and shuttering including strutting, propping etc. and removal of form for 106 Foundations, footings, bases of columns, etc. for mass concrete 107 Columns, Pillars, Piers, Abutments, Posts and Struts 108 SUB HEAD-I-SANITARY INSTALLATIONS 109 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 110 Providing & fixing toilet paper holderC.P. brass 111 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 112 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 113 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 114 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 115 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 116 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 117 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 118 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 15 mm nominal bore 119 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore 120 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 121 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia 122 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 123 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 124 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 510x1040 mm bowl depth 200 mm 125 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe 32mm Dia 126 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 127 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore 128 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 129 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. Granite Stone of approved shade 130 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 131 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 132 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters 133 SUB HEAD-II-WATER SUPPLY 134 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 135 Concealed work, including cutting chases and making good the walls etc. 136 For Internal Toilet 137 15 mm nominal outer dia Pipes 138 20 mm nominal outer dia Pipes 139 25 mm nominal outer dia Pipes 140 32 mm nominal outer dia Pipes 141 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 142 Internal work - Exposed on wall 143 20 mm nominal bore 144 25 mm nominal bore 145 32 mm nominal bore 146 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 147 Terrace loop & Tank Filling Pipe 148 50 mm nominal bore 149 65 mm nominal bore (i/c two coat of synthetic enamel paint) 150 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- 151 Lehry Make Automatic OHT Level Control System Consist of Following Items 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 50mm 152 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 50mm diameter pipe 153 Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. 154 15mm dia (9 mm thickness) 155 20mm dia (9 mm thickness) 156 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore 157 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 158 For vertical pipe connection with terrace ringmain 159 20 mm nominal bore 160 25mm nominal bore 161 32mm nominal bore 162 50mm nominal bore 163 65mm nominal bore 164 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 165 25mm dia. 166 50mm dia. 167 65mm dia. 168 150mm dia. 169 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 170 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 171 Single Push Fit Coupler 172 110 mm dia 173 Single tee with door 174 110x110x110 mm 175 Plain bend 87.5 deg 176 110 mm dia 177 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 178 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 179 SUB HEAD : IV - INTERNAL DRAINAGE 180 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 181 Internal Toilet (Soil & Waste Pipe) 182 75 mm 183 110 mm 184 Exposed on Wall (Soil & Waste Pipe) 185 110 mm 186 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 187 Bend without door (87.5°) 188 110mm bend 189 Bend without door (45°) 190 100mm 191 75mm 192 Y Fitting without door 193 100mm 194 75mm 195 Reduced Y Fitting without door 196 100mm x 75mm 197 Single Tee without door 198 110mm 199 75 mm 200 Single Tee with door 201 110mm 202 Reduced Tee with door 203 110mm x 75mm 204 Coupler 205 110mm 206 Clean Out Plug (COP) 207 110mm 208 75 mm 209 Vent Cowl 210 110mm 211 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 212 For Wash basin & Urinal 213 50mm dia. Pipe 214 32mm dia. Pipe 215 Elbow (90°) 216 50mm 217 32mm 218 Elbow (45°) 219 50mm 220 32mm 221 T fitting 222 50mm 223 32mm 224 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) 225 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 226 110mm x 75mm (Toilet) 227 110mm x 75mm (Kitchen) 228 Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 229 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 230 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 231 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 232 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 233 COST OF SEWERAGE WORKS 234 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 80 mm to 300 mmdiameter 235 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 236 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 237 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 238 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 239 Extra for depth for manholes: 240 Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 241 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 242 Extra for depth for manholes: Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 243 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 244 Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset 245 COST OF EXTERNAL WATER SUPPLY WORKS 246 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 247 65mm nominal bore. 248 50mm nominal bore. 249 32mm nominal bore. 250 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 251 65mm nominal bore. 252 50mm nominal bore. 253 32mm nominal bore. 254 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 255 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 RAIN WATER HARVESTING 257 RECHARGE PITS 258 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 259 In all kind of soil upto 1.5m depth 260 In all kind of soil upto 1.5m to 3.0m. depth 261 In all kind of soil upto 3.0m to 4.5m. depth 262 In all kind of soil upto 4.5 m to 6.0m. depth 263 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 264 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 265 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 266 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 267 12mm cement plaster on rough side of single or half brick wall mix1:3 (1 cement : 3 Coarse sand) 268 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 269 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 270 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. 271 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 272 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 273 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 274 Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. 275 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 276 DESILTING CHAMBER 277 Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. 278 In all kind of soil upto 1.5m depth 279 In all kind of soil upto 1.5m to 3.0m. depth 280 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 281 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 282 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 283 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 284 15mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand) 285 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar 286 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 287 DRAINAGE NETWORK 288 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 289 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 290 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 291 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 292 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 293 Drain 300 wide average.Depth 45 cm with R.C.C. slab 294 Drain 450 wide average.Depth 45 cm with R.C.C. slab 295 SEPTIC TANK & SOAK PIT 296 Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M 297 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 298 In all kind of soil upto 1.5m depth 299 In all kind of soil upto 1.5m to 3.0m. depth 300 In all kind of soil upto 3.0m to 4.5m. depth 301 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 302 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 303 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 304 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 305 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 306 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 307 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 308 Providing & fixing 75mm dia vent pipes. 309 Providing & fixing of 75mm dia cast iron terminal guard. 310 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 311 M.D. -10- Circular shape 500mm internal diameter 312 M.D. -2.5- Circular shape 450mm internal diameter 313 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 314 CONSTRUCTIONOFTUBEWELL(suitable for 1000 lpm yield) 315 Transportation Charges of drilling equipment including assembly and other material as required. 316 Drilling of 675 mm. dia by rotary machine 317 Supply & laying of 350 mm. dia housing pipe (8 mm. thick) 318 Supply & laying of 200 mm. dia blind pipe (8 mm. thick) 319 Supply & laying of 200 mm. dia slotted pipe (8 mm. thick) 320 Supply & fixing of 350 mm. dia Socket 321 Supply & fixing of 200 mm. dia Socket 322 Supply & fixing of 200 mm. dia Bail plug 323 Supply & fixing of 350 mm. dia well cap 324 Supply & fixing of 350x200 mm. dia reducer. 325 Supply & fixing of 350 mm. dia housing clamp 326 Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I. 327 Development by air compressor including Transportation. 328 Development by O.P. Unit including Transportation. 329 Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition. A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. B - Total Head of pump set 45 m. 330 Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm. 331 Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set. 332 Supply of 80mm dia M.S. column pipe of class C both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements. 333 Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc. 334 Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make. 335 Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make. 336 Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour. 337 Supply of 80mm dia C.I. tee heavy quality i/c cost of material. 338 Supply of Guru/Fibing or equivalent make pressure gauge. 339 Erection & commissioning of pumping plants complete along with electric wiring. 340 Supply of steel wire rope of 1/2 size 341 S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing. 342 S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site. 343 S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core 344 FIRE FIGHTING SYSTEM 345 Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 346 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm nominal bore (pipe in pump room & external) 347 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 2 way - 100 mm dia M.S. Pipe (Siamese& draw out connection) 348 SUB HEAD-II: INTERNAL FIRE FIGHTING WORKS(HYDRANT SYSTEM) 349 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head 350 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 351 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 352 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. 353 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. 354 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 355 80 mm nominal bore 356 100 mm nominal bore 357 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal 358 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m 359 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun metal 360 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal 361 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 362 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 363 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 364 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 365 SUB HEAD-III: FIRE EXTINGUSHER 366 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 367 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 368 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 369 SUB HEAD-IV: ELECTRICAL WORKS (For Terrace Pump) 370 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. 3CX6Sqmm AL XLPE Cable 371 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 3CX6Sqmm AL XLPE Cable 372 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 373 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness. 374 SCHEDULE OF QUANTITIES FOR ELECTRICAL WORKS 375 SUBHEAD I- WIRINGPOINTS 376 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash 377 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 378 Wiring point for 5Amp plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 379 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 380 Addition for light / fan points with modular type switchin place of piono type switch. 381 Addition for plugpointswith modular type switchin place of piono type switch. 382 Addition for Exhaust fanpointswith modular type switchin place of piono type switch. 383 Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. 384 Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work. 385 Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C. 386 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 387 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 388 Supply and wiring of submain 2 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 6 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 389 Supply and wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with two number 10 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 390 Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100 V grade single core Copper conductor cable in 40 mm dia PVC conduit concealed in wall, with two number 10 sqmm single core Copper conductor cable as earth continuity wire drawn in coudit including matching colour wash etc., cable as earth contunity wire etc. complete in all respects. 391 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone) 392 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 393 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. 394 Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. 395 Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. 396 Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep 397 Supplyfixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 398 Supply and fixing of recess/surface mounting round 24 to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set complete in all respect.CAT- AAA 399 Supply and fixing of 1X1 recess/surface mounting 18 Watt to 20 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects.CAT- AAA 400 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 401 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 402 Supply & fixing of recess/Surface mounting round 6 to 8 watt, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respect.(CAT: AAA) 403 Supply and fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA) 404 Supply and fixing ofbatten/angle holder complete all respect. 405 Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect.CAT-AAA 406 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.CAT-AAA 407 NON SCH. 408 Supply and fixing of 17 watt LED Mirror Light and complete in all respect. 409 Supply and fixing of 12 watt LED bulb complete in all respect. 410 Supply and fixing of 40 watt Tungsten Filament Antique Glass Light Incandescent Bulbs Vintage Base E27 Bulb Yellow Light. complete in all respect. 411 Supply and fixing of Dome Shape Pendent Light,complete in all respect, Make : Havells, Wipro, Philips ,Jaguar,Bajaj or Eq. 412 SUBHEAD III-DISTIBUTION BOARD 413 Supply and fixing of surface/flush mounting distribution boards with additional metal door without MCB complete in all respects.(CAT A) 414 8 Way SPN 415 12 Way SPN 416 6 Way TPN 417 8 Way TPN 418 4 Way VTPN 419 Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) 420 Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A) 421 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve(CAT: A) 422 40 Amp. TP MCB(CAT: A) 423 40 Amp. FP MCB(CAT: A) 424 63 Amp. FP MCB(CAT: A) 425 S&F and making connection of 25A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. 426 S&F and making connection of 40A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. 427 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. (CAT: A) 428 Non-Sch. 429 Supply fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. FP MCCB (25 KA) Thermal Magnetic release 430 SUBHEAD IV-CABLES 431 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 432 300 sq. mm 3.5 core 433 185 sqmm3.5 core 434 35 sqmm3.5 core 435 25 sqmm3.5 core 436 6 sqmm3 core 437 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of EngineerIncharge 438 300 sqmm3.5 core 439 185 sqmm3.5 core 440 35 sqmm3.5 core 441 25 sqmm3.5 core 442 6 sqmm3 core 443 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 444 300 sqmm 445 185 sqmm 446 150 sqmm 447 95 sqmm 448 35 sqmm 449 25 sqmm 450 16 sqmm 451 6 sqmm 452 SUBHEAD V-EARTHING 453 Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. 454 Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead ofone no. 8SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects. 455 Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects. 456 Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects.. 457 Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. 458 Supply & fixing of two number 8 SWG G.I. wire in 15mm dia GI pipe for earthing purpose as required complete in all respects. 459 L.T. PANEL 460 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 461 The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmBUILDING MAIN LT PANELIncoming :1 No 250 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 200 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 125 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity1 No 200 Amp. 4P ATSMetering :1 Set of CTs one of 250/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 200/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 125/ 5Amp ratio for Multifunction Meter1 Set of CTs one of 63/ 5Amp ratio for Multifunction Meter4 Set of Phase Indication Lamp.Bus Bar :One (1) No. 300 Amp. FP aluminimum bus bar of suitable length.One (1) No. 160 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.100 Amps FP MCCB of 25KA - 2 No63 Amps FP MCCB of 25KA - 10 No40 Amps FP MCCB of 25KA - 1 No32 Amps DP MCB of 10KA - 2 NoSPARE & SPACEPanel described as above 462 METERING PANELIncoming :1 No 100 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking CapacityMetering :1 Set of CTs one of 100/ 5Amp ratio for Multifunction Meter1 Set of Phase Indication Lamp.Bus Bar :One (1) No. 120 Amp. FP aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.63 Amps FP MCB of 10KA - 2 No32 Amps DP MCB of 10KA - 9 NoSingle Phase Energy Meter- 8 Nos.Three Phase Energy Meter- 1 Nos.SPARE & SPACEPanel described as above 463 SUBHEAD VII-TELEPHONE SYSTEM 464 S/F MODULAR BOXES, BASE & COVER PLATE :- 465 Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm) 466 S/F MODULAR TYPE SWITCH / SOCKET :- 467 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. 468 Telephone socket outlet 469 TV Antenna socket outlet 470 Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair 471 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. 472 Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required 473 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 474 NON SCH. 475 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. RJ-45 Jack With Cat 6 -2M 476 Supplying telephone wire following pair 0.6 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 5 Pair 477 S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same 478 SUBHEAD VIII-CABLES TRAY & RACEWAY 479 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 480 100 mm wide x 50 mm depth x 1.6 mm thickness. 481 150 mm wide x 50 mm depth x 1.6 mm thickness. 482 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 483 100 mm wide x 50 mm depth x 1.6 mm thickness. 484 150 mm wide x 50 mm depth x 1.6 mm thickness. 485 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 486 100 mm wide x 50 mm depth x 1.6 mm thickness. 487 150 mm wide x 50 mm depth x 1.6 mm thickness. 488 Providing, Laying and Fixing following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 150mm dia 489 NON SCH. 490 Providing and Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm 491 Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 492 300mm sweep. 493 600mm sweep. 494 Supply of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. 495 Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 900 mmx 1000 mm deep 496 (NON SCH) 497 Supplying, Installation and commissioning of AMF start silent type 50 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase Model- 4K1080TAG2 Engine BHP-80 rated at 1500 RPM, Water Cooled, Four Stroke Electric Start 4 Cylinders Diesel Engine conforming to BS 5514 with capacity Of 10%, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms Complete with axial flow heavy duty exhaust fans for adequate ventilation exhaust of hot air etc including making of cement concrete foundation of 1: 2:4 (1 cement 2 sand and 4, 40mm graded stone aggregate) as per manufacturer recommendation complete as per specifications and conditions as required. (The diesel engine and alternator shall be so rated to deliver the specified output at site condition complete with control cable etc. as required. 498 SUBHEAD XI- Solar Photovoltaic Power Plant 499 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium /GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above,manufactured in India, conforming to IS 14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV module sused in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350- 800 V DC Input voltage range and 400V AC, three phase, 4 wire,50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. as required. 500 ESTIMATE OFFOR 4.5 Mt. WIDE C.C. ROAD 501 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( PWD-251) 502 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc(DSR 16.1)*0.8222 503 Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(DSR 16.3.2 and 16.4)*0.8222 504 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(DSR 16.43.2)*0.8345 505 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners,etc(DSR 16.45)*0.8222 506 Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8222) Using grade A sealing compound. 507 TREMIX FLOORING IN PARKING AREA 508 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge etc( dsr 2.1) 509 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metr etc dsr 16.1 510 Supplying and stacking at site. 16.3.1 90 mm to 45 mm size stone aggregate etc and Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .(dsr16.3.2 and 16.4) 511 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,etc(sor 16.43.2) 512 Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1*0.8681) Using grade A sealing compound. 513 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 514 [ LANDSCAPING WORK ] 515 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). 516 Carrigae of sludge upto 5 K.M. 517 Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm 518 Carrigae of manure upto 5 K.M. 519 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. 520 Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately). 521 Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). 522 Holes 0.9 m dia. and 0.90 m deep. 523 Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 524 Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge. 525 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. 526 Sand Stone Pathway 527 Supplying & Laying of P.C.C. in 1:4:8 (1 Cement :4 Coarse sand: 8 stone aggregate 40 mm nominal size in base includinmg supply of all material labour T&P etc. 528 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone 529 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 530 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 531 [ COBBLE PATHWAY ] 532 Earth work in excavation 533 Excavation by Manual means 534 Surface dressing 535 P.C.C. 1:4:8 536 B/W in 1:4 ( 1Cement :4 Coarse sand) 537 12 mm plaster in 1:3 outer 538 12 mm plaster in 1:3 inner 539 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge. 540 [ ABSTRACT OF COST - CHHATRI ] 541 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles 542 Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 543 Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. 544 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 545 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 546 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. 547 As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete). 548 As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete). 549 As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete). 550 As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. 551 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 552 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 553 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) 554 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with roughbacking. 30 mm thick 555 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 556 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm Red sandstone in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 557 Supply/FIXINGOF Installation Of Fountain 558 [ ABSTRACT OF COST - POND (SIZE - 30.0X 3.3 MT. ] 559 Earth workinexacavationintrenches for foundations in ordinarysoil (loan clay or sand) includingliftupto 1.5m and leadup to 30m.&including filling watering & ramming of excavated earthin to trenchesorintothespace between the building& thesidesof foundation trenchesor in totheplinth and removal & disposal of surplus excavated earthas directedbytheEngineer i/c upto adistanceof 30 m fromthe foundation trenches. 560 Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost ofform-work,in foundation and floors. 561 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size)(Footing) 562 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 563 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 564 Water proofing of pool as per spec.of DON building Chemicals. 565 Providing & fixing Glass Mosaic tiles in pond. 566 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red Area of slab over 0.50 sqm 567 Centering and shuttering including strutting, propping etc. and removal of form for. 568 Foundations, footings, bases of columns, etc. for mass concrete 569 Columns, Pillars, Piers, Abutments, Posts and Struts 570 Underground Sump 571 Supply installing , testing and commissioning of non clog submerssible tupe drainage/dewatering pumpset.Product Type: SUBMERSIBLE DRAINAGE PUMP Product ConfigurationPump Classification: Standard PumpComponent Materials Volute Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Motor Specifications Phase: 3 Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework Connection Float Switch: With Float Switch Solids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9mEach Pump Set Detail = 1W+1S ( 2No. for LOWER GROUND TOILET) 572 Filling of carted earth. (230.13*4) 573 COST OF LIFT 13 PERSON 574 COST OF SOLAR PHOTO VOLTAIC PLANT 575 COST OF D.G.SET - 50 KVA 576 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
35.
Housing Urban and Rular Development #9443251 Technical Bid
Tender For Development Of Tourism Office At Distt. Deoria, 1 TOURIST FACILITATION CENTER (Civil) 2 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. Excavation by Manual means [Special tools] 3 From Lvl. 0.00 To 1.50 Mtr 4 Filling of carted earth. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8Km from the site of work and including watering, dressing etc. Rate to include cost of all materials, labour, T&P etc. required for proper completion the work. 6 Concrete with 4cm. Gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour, tools and plants etc. required for proper completion the work. 7 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete 8 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 9 (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. 10 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excludingthe cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto plinth Lvl.(M-25) 11 R.C.C. work in Footing 12 R.C.C. work in Column 13 R.C.C. work in Beam 14 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excludingthe cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto Above Lvl.(M-25) 15 R.C.C. work in Lintel 16 R.C.C. work in Slab 17 R.C.C. work in Beam 18 R.C.C. work in Column 19 M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, T & P etc reqiored for proper completion of the work. 20 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 21 Providing machine made Wire Cut Bricks in Arches where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 22 Extra for forming cavity 42 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 460 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 23 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand) 24 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 25 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 26 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 27 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 28 Upto Plinth Lvl. 29 Above Plinth Lvl. 30 15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth. 31 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand 32 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand 33 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 34 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily..Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 35 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm 36 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily..Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 37 Providing and fixing three-layer construction, wooden plank/engineered Wood size185—200 mmX 2000-2426 mmof 3 strip oak with a total thickness of 15 mm and a wear layer thickness of 3.5mm should be resandable up to 2 to 3 times. Surface Treatment: Matt/ Ultra matt Lacquer, Core: Pine/ Spruce/ Alder. Joint: Woodloc 5S, fifth-generation locking system, Moisture Content as per EN 13183: 7%, Reaction to fire as per EN13501-2:1 Dfl- s1CARB 2 compliant, Biological Durability as per EN350-2 Class1 confirming to strict quality and environment norms. It should be certified by PEFC, FSC, Blue Angel, and Real Wood.Matching Accessories like skirting & profile with,. Installation should be done by a trained and authorized team on Zero level of the hard surface .Make-Kahrs, Armstrong 38 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 39 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 40 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 41 Granite of any colour and shade (Area of slab upto 0.50 sqm) 42 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 43 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. 44 (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 45 Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 46 35 mm thick. 47 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 48 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 49 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 50 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 51 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 52 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) 53 Note: For uPVC frame, sash and mullion extruded profilesminus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 54 Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 55 Float glass panes 56 5.0 mm thick glass panes (weight not lessthan 12.50 kg/sqm). 57 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 58 Providing and fixing to existing door frames. 59 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelleddoor shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturatedpolyester resin, moulded to 3 mm thick FRP laminate forforming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 60 Supply and fix powder coated Aluminium louvered door double leaves type overall size as per drawing for maintenance opening in the service area ,with all required fixing angles, bolts, welding including1’ wide Aluminium Louvers of approved shade in door Including allaccessories required for installation of the louvers, painting and priming and all required as per drawings and Engineer instructions in charge 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 63 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 64 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent) 65 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 66 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 67 Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. 68 (a) 300mm x 16mm 69 P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc. 70 (a) 250 mm x 10mm 71 (b) 200 mm x 10mm 72 Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 73 125 mm 74 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 75 Providing & laying of light cinder filling under floor of toilets & other sunken roofs. 76 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 77 Construction of drain along with apron. 78 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK 79 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: 80 a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: 81 b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. 82 c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. 83 d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. 84 Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” 85 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. 86 The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm 87 (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 88 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 89 Providing & fixing mineral fibre false ceiling tiles at all height of size 595 x 595 mm. of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85% Thermal Conductivity k = 0.052- 0.057 w/m K, Fire performance as per (Bs 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all around galvanized iron secion of 0.33mm thick (galvanized @ 120 gsm) 90 comprising of main T-Runners of 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item (galvanised @ 80 gsm) 50mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to 91 centre along main T. The system should rest on periphery walls/ partitions with the help of G.I. perimeter wall angle of size 24x24x3000mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyster baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 92 With 16 mm thick beveled tegular mineral fibre false ceiling tile 93 Centering and shuttering including strutting, propping etc. and removal of form for 94 Foundations, footings, bases of columns, etc. for massconcrete 95 Suspended floors, roofs, landings, balconies and accessplatform 96 Lintels, beams, plinth beams, girders, bressumers andcantilevers 97 Columns, Pillars, Piers, Abutments, Posts and Struts 98 Providing, Suppling & fixing of cultural Terracotta tile mural work of 20mm thick inspired from the extraction of Ramayana and the Local Tangible context as per architect incharge. 99 FIRE FIGHTING WORKS 100 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 101 150 mm dia. 102 100 mm dia. 103 80 mm dia. 104 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 105 150 mm dia. 106 100 mm dia. 107 80 mm dia. 108 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 109 150 mm dia. 110 100 mm dia. 111 80 mm dia. 112 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 113 2 way - 100 mm dia M.S. Pipe (Siamese Connection) 114 4 way - 150 mm dia M.S. Pipe 115 TOTAL OF SUBHEAD-I 116 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump) 117 (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 118 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 119 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 120 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 121 900 lpm at 35 m Head 122 450 lpm at 35 m Head 123 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 124 Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) 125 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 126 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 127 150 mm dia. 128 100 mm dia. 129 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 130 150 mm dia. 131 100 mm dia. 132 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 133 80 mm nominal bore 134 100 mm nominal bore 135 150 mm nominal bore 136 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 137 Single headed Gunmetal 138 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 139 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 140 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 141 40 m 142 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 143 Gun metal 144 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 145 Gun metal 146 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 147 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 148 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 149 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 150 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 151 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 152 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 153 TOTAL OF SUBHEAD-III 154 FIRE FIGHTING PANEL 155 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 9.3 KW/12.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. Star delta starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 156 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 157 Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 158 3 Core, X 10 sqmm. 159 3 Core, X 6 sqmm. 160 Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 161 3 Core, X 10 sqmm. 162 3 Core, X 6 sqmm. 163 Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathedarmoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 164 4 x 2.5 sq.mm 165 2 x 2.5 sq.mm 166 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 167 150 mm width x 50mm depth x 1.6 mm thickness. 168 FIRE ALARM SERVICES 169 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 170 6 zone panel for fire alarm system 171 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. 172 Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. 173 Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. 174 Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. 175 Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. 176 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 177 4-Zone Panel. 178 6-Zone Panel. 179 10-Zone Panel. 180 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 182 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. 184 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. 185 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 186 INTERNAL W/S & SANITATION WORK 187 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 188 W.C. pan with ISI marked white solid plastic seat and lid 189 Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. 190 Providing & fixing toilet paper holder 191 C.P. brass 192 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 193 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 194 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 195 White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 196 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 197 (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 198 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 199 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 200 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 201 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 202 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 203 15 mm nominal bore 204 Providing and fixing uplasticised PVC connection pipe with brass unions : 205 45 cm length 206 15 mm nominal bore 207 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 208 100 mm diameter 209 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 210 15 mm nominal bore 211 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 212 15 mm nominal dia 213 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 214 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 215 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 216 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 217 Kitchen sink with drain board 218 510x1040 mm bowl depth 200 mm 219 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete 220 Flexible Pipe 221 32mm Dia 222 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 223 15mm nominal bore 224 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 225 15mm nominal bore 226 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 227 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 228 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. 229 Granite Stone of approved shade 230 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 231 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 232 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. 233 Capacity 25 Liters 234 TOTAL OF SUBHEAD-I 235 SUB HEAD-II-WATER SUPPLY 236 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 237 Concealed work, including cutting chases and making good the walls etc. 238 For Internal Toilet 239 15 mm nominal outer dia Pipes 240 20 mm nominal outer dia Pipes 241 25 mm nominal outer dia Pipes 242 32 mm nominal outer dia Pipes 243 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 244 Internal work - Exposed on wall 245 20 mm nominal bore 246 25 mm nominal bore 247 32 mm nominal bore 248 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 249 Terrace loop & Tank Filling Pipe 250 40 mm nominal bore 251 50 mm nominal bore 252 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 253 40mm diameter pipe 254 50mm diameter pipe 255 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 256 40mm diameter pipe 257 50mm diameter pipe 258 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 259 For vertical pipe connection with terrace ringmain 260 20 mm nominal bore 261 25mm nominal bore 262 32mm nominal bore 263 40mm nominal bore 264 50mm nominal bore 265 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 266 25 to 40 mm nominal bore 267 50 to 80 mm nominal bore 268 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 269 40 mm nominal bore, 206 mm long, weighing not less than 690 gms 270 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 271 Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. 272 15mm dia (9 mm thickness) 273 20mm dia (9 mm thickness) 274 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- 275 Lehry Make Automatic OHT Level Control System Consist of Following Items 276 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 277 40mm 278 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 279 25mm dia. 280 32mm dia. 281 40mm dia. 282 50mm dia. 283 65mm dia. 284 80mm dia. 285 100mm dia. 286 150mm dia. 287 200mm dia. 288 250mm dia. 289 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 290 110 mm dia (for rain water) 291 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 292 Single Push Fit Coupler 293 110 mm dia 294 Single tee with door 295 110x110x110 mm 296 Plain bend 87.5 deg 297 110 mm dia 298 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 299 110 mm dia 300 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 301 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 302 All kind of soil 303 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 304 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 305 100mm dia SWpipe 306 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 307 Internal Toilet (Soil & Waste Pipe) 308 75 mm 309 110 mm 310 Exposed on Wall (Soil & Waste Pipe) 311 110 mm 312 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 313 Bend without door (45°) 314 75mm 315 110mm 316 Bend without door (87.5°) 317 75mm bend 318 110mm 319 Y Fitting without door 320 75mm 321 110mm 322 Single Tee without door 323 75mm 324 110 mm 325 Single Tee with door 326 75mm 327 110 mm 328 Bend with door (87.5°) 329 75mm 330 110 mm 331 Clean Out Plug (COP) 332 75mm 333 110 mm 334 Reduced Y Fitting without door 335 110mm x 75mm 336 Reduced Tee with door 337 110mm x 75mm 338 Coupler 339 75mm 340 110mm 341 Vent Cowl 342 110mm 343 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 344 For Wash basin & Urinal 345 32mm dia. Pipe 346 50mm dia. pipe 347 Elbow (45°) 348 32mm 349 50mm 350 Elbow (90°) 351 32mm 352 50mm 353 T fitting 354 32mm 355 50mm 356 Coupler 357 32mm 358 50mm 359 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 360 110mm x 75mm x 50mm/40mm (Toilet) 361 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 362 110mm x 75mm (Toilet & Kitchen) 363 Providing and fixing PTMT grating of approved quality and colour. 364 Rectangular type with openable circular lid 365 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 366 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 367 150 x 100mm size P-type 368 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 369 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 370 100 mm diameter 371 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 372 All kind of soil 373 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 374 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 375 100mm dia SWpipe 376 INTERNAL ELECTRIFICATION WORKS 377 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 378 Group - B 379 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 380 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required 381 Group -A 382 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 383 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 384 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 385 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 386 2 X 6 sq. mm + 1 X 4 sq. mm earth wire 387 2 x 10 sq.mm + 1 x 6sq.mm. earth wire 388 2 x 16 sq.mm + 1 x 6sq.mm. earth wire 389 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire 390 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 391 4 x 16 sq.mm + 2 x 6sq.mm. earth wire 392 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 393 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 394 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 395 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 396 Wiring for light/ power plug plug with 2 X 4 sq. mm FRLC PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FRLC PVC insulated copper conductor single core cable for loop earthing as required 397 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 398 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 399 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 400 5/6 A switch 401 3 pin 5/6 A socket outlet 402 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 403 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 404 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing. 405 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 406 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 407 Upto 450 mm sweep 408 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 409 Supply of surface/Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 410 Supply of surface mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 411 Supply of LED 4ft 2x20W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor Make Jaguar LUNI01X220XW, Philips / BAJAJ or Eq. 412 Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 413 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 414 Supply ofSurface mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect 415 Supply of Surface mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 416 Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. 417 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 418 Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, 419 Supplying and fixing brass batten/ angle holder including connection etc. as required. 420 Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. 421 Supplying of 9 Watt Decorative LED Wall Light complete in all respect. 422 MACTY SURFACE DOWNLIGHT Divinity Sarface Macty Up and Down Light Outdoor Fixture (IP-65) Optical system=LensWattage=2x10WLumen=1600lmCCT=3000KCRI>80Beam Angle=12° /24° / 36° / 60°Driver=Non Dimmable Material=Aluminium Dia castingStandard Lifetime=L70Minimum 50000 HoursFinish=BlackDimension=Dia=100mm,H=100mm 423 Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver andapable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 424 Supply and Fixing 24 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) 425 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 426 Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. 427 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 428 300mm EXHAUST FAN 429 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 430 63 A,25KA,FP MCCB 431 100 A,30KA,FPMCCB 432 125 A,36KA,FPMCCB 433 160 A,25KA,FP MCCB 434 200 A, 36KA,FPMCCB 435 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 436 6 Way Double Door 437 8 way, Double door 438 12 way, Double Door 439 16 way, Double Door 440 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 441 4 Way Double door 442 6 way Double door 443 8 way Double door 444 12 way Double door 445 Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 446 4 way (4 + 12), Double door 447 8 way (4 + 24), Double door 448 Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. 449 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 450 40 amps SP MCB 451 40 amps DP MCB 452 63 amps DP MCB 453 40 amps TP MCB 454 63 amps TP MCB 455 40 amps 4P MCB 456 63 amps 4P MCB 457 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 458 40 amps 459 63 amps 460 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 461 40 amps 462 63 amps 463 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 464 25 amps 465 40 amps 466 63 amps 467 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 468 Single pole 469 Double pole 470 Triple pole 471 Triple pole and neutral 472 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 473 Supplying and fixing 1P LCD Energy Meter 5-30A with BOX 474 Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter 475 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 476 Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V C curve DP MCB complete withconnections, testing and commissioning etc. as required. 477 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 478 90 mm dia (OD-90 mm & ID-76 mm nominal) 479 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. 480 The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 481 The minimum clearances between bus bars shall be as follows : 482 Phase to phase - minimum 20mm 483 Phase to neutral-minimum 15mm 484 MAIN PANEL 485 Same as above item but following mountings. 486 INCOMER:- 487 One (1) No 160 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity with thermal Magnetic release 488 Metering : 489 1 Set of CTs one of 160/ 5Amp ratio for Multifunction Meter 490 One (1) Set of Phase Indication Lamp. 491 Bus Bar : 492 One (1) No.200 Amp.TPN aluminimum bus bar of suitable length. 493 Outgoing : 494 Phase indication lamps on each outgoing to be provided. 495 40 Amps 4P MCCB of 25KA (Ics=Icu)Breaking Capacity- 6 No 496 63 Amps 4P MCCB of 25KA (Ics=Icu)Breaking Capacity- 2 No 497 10 Amps DP MCB of 10KA (Ics=Icu)Breaking Capacity- 2 No 498 2 Nos.Space & Spare 499 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 500 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 501 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 502 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 503 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 504 Providing and Fixing 6 SWG dia G.I. Wire on surface or in recess for connection etc. as required. 505 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 506 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 507 Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 508 2 Pair (4 core) 509 Providing, laying, connecting and testing of multi-core telephone unarmoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. 510 100 Pair telephone cable 511 20 Pair telephone cable 512 10 Pair telephone cable 513 5 Pair telephone cable 514 Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 515 5 Pair tag block 516 10 pair tag block 517 20 pair tag block 518 100 pair tag block 519 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 520 20mm dia PVC conduit 521 25mm dia PVC conduit 522 32mm dia PVC conduit 523 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 524 1 or 2 Module (75mmX75mm) 525 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 526 Telephone socket outlet 527 TV antenna socket outlet 528 Bell Push 529 RJ-45 Data Socket outlet 530 Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. 531 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 532 1 run of cable 533 Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. 534 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 535 Up to 35 sq.mm. 536 Above 35 sq.mm. and up to 95 sq.mm. 537 Above 95 sq.mm. and upto 185 sq.mm. 538 Above 185 sq.mm. and up to 400 sq.mm. 539 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required 540 Up to 35 sq.mm. 541 Above 35 sq.mm. and up to 95 sq.mm. 542 Above 95 sq.mm. and upto 185 sq.mm. 543 Above 185 sq.mm. and up to 400 sq.mm. 544 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 545 Up to 35 sq.mm. 546 Above 35 sq.mm. and up to 95 sq.mm. 547 Above 95 sq.mm. and upto 185 sq.mm. 548 Above 185 sq.mm. and up to 400 sq.mm. 549 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 550 Up to 35 sq.mm. 551 Above 35 sq.mm. and up to 95 sq.mm. 552 Above 95 sq.mm. and upto 185 sq.mm. 553 Above 185 sq.mm. and up to 400 sq.mm. 554 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required 555 Up to 35 sq.mm. 556 Above 35 sq.mm. and up to 95 sq.mm. 557 Above 95 sq.mm. and upto 185 sq.mm. 558 Above 185 sq.mm. and up to 400 sq.mm. 559 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 560 Up to 35 sq.mm. 561 Above 35 sq.mm. and up to 95 sq.mm. 562 Above 95 sq.mm. and upto 185 sq.mm. 563 Above 185 sq.mm. and up to 400 sq.mm. 564 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required 565 Upto 35 sq. mm (clamped with 1mm thick saddle 566 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp 567 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp 568 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 569 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 570 Upto 35 sq. mm (clamped with 1mm thick saddle) 571 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 572 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 573 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 574 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 575 3.5 x 400 sq.mm. 576 3.5 x 300 sq.mm. 577 3.5 x 240 sq.mm. 578 3.5 x 185 sq.mm 579 3.5 x 150 sq.mm 580 3.5 x 120 sq.mm 581 3.5 x 95 sq.mm 582 3.5 x 70 sq.mm 583 3.5 x 50 sq.mm 584 3.5 x 35 sq.mm 585 3.5 x 25 sq.mm. 586 4 x 25 sq.mm 587 4 x 16 sq.mm 588 4 x 10 sq.mm 589 4 x 6 sq.mm 590 2 x 16 sq.mm, 591 2 x 10 sq.mm, 592 2 x 6 sq.mm, 593 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 594 2 X 6 sq. mm (19mm) 595 2 X 10 sq. mm (19mm) 596 2 X 16 sq. mm (22mm) 597 3½ X 25 sq. mm (28mm) 598 3½ X 35 sq. mm (32mm) 599 3½ X 50 sq. mm (35mm) 600 3½ X 70 sq. mm (38mm) 601 3½ X 95 sq. mm (45mm) 602 3½ X 120 sq. mm (45mm) 603 3½ X 150 sq. mm (50mm) 604 3½ X 185 sq. mm (57mm) 605 3½ X 225 sq. mm (62mm) 606 3½ X 240 sq. mm (62mm) 607 3½ X 300 sq. mm (70mm) 608 3½ X 400 sq. mm (82mm) 609 4 X 10 sq. mm (25mm) 610 4 X 16 sq. mm (28mm) 611 Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required 612 100 mm dia 613 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 614 100mm dia 615 150 mm dia 616 250 mm dia 617 300 mm dia 618 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 619 90 mm dia (OD-90 mm & ID-76 mm nominal) 620 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 621 100 mm wide x 50 mm depth x 1.6 mm thickness. 622 150 mm wide x 50 mm depth x 1.6 mm thickness. 623 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 624 100 mm wide x 50 mm depth x 1.6 mm thickness. 625 150 mm wide x 50 mm depth x 1.6 mm thickness. 626 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray Tee (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceilingwith G.I. suspenders including G.I. bolts & nuts, etc. as required. 627 100 mm wide x 50 mm depth x 1.6 mm thickness. 628 EXTERNAL SEWERAGE & WATER SUPPLY SYSTEM 629 COST OF SEWERAGE WORKS 630 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 631 up to 1.50 m depth 632 Pipes 80 mm to 300 mmdiameter 633 1.50 m to 3.00 m depth 634 Pipes 80 mm to 300 mmdiameter 635 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) 636 Depth not exceeding 1.5 meter 637 Depth 1.5 to3.00meter 638 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 639 150 mm.dia. RCCPipes 640 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 641 150 mm.dia. RCCPipes 642 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. 643 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 644 With common burnt clay FPS (non modular) bricks of class designation 75 645 (i) For Sewer Line 646 Extra for depth for manholes: 647 Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 648 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). 649 With common burnt clay FPS (non modular) bricks of class designation 75 650 (i) For Sewer Line 651 Extra for depth for manholes: 652 Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 653 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 654 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 655 80mm nominal bore. 656 65mm nominal bore. 657 50mm nominal bore. 658 40mm nominal bore. 659 32mm nominal bore. 660 25mm nominal bore. 661 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 662 80mm nominal bore. 663 65mm nominal bore. 664 50mm nominal bore. 665 40mm nominal bore. 666 32mm nominal bore. 667 25mm nominal bore. 668 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) 669 80mm nominal bore. 670 65mm nominal bore. 671 50mm nominal bore. 672 40mm nominal bore. 673 32mm nominal bore. 674 25mm nominal bore. 675 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 676 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 677 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : 678 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 679 EXTERNAL SEWERAGE SYSTEM (SEPTIC TANK) 680 SEPTIC TANK & SOAK PIT 681 Size :- Length = 5.0 M. Width = 2.0M Total Depth =3.00M 682 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 683 In all kind of soil upto 1.5m depth 684 In all kind of soil upto 1.5m to 3.0m. depth 685 In all kind of soil upto 3.0m to 4.5m. depth 686 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 687 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 688 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 689 Suspended floors, roofs, landings, balconies and access platform. 690 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 691 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 692 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 693 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 694 Providing & fixing 75mm dia vent pipes. 695 Providing & fixing of 75mm dia cast iron terminal guard. 696 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 697 M.D. -10- Circular shape 500mm internal diameter 698 M.D. -2.5- Circular shape 450mm internal diameter 699 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 700 With F.P.S. bricks 701 RAIN WATER HARVESTING WORKS 702 RECHARGE PITS 703 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 704 In all kind of soil upto 1.5m depth 705 In all kind of soil upto 1.5m to 3.0m. depth 706 In all kind of soil upto 3.0m to 4.5m. depth 707 In all kind of soil upto 4.5 m to 6.0m. depth 708 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 709 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 710 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 711 Suspended floors, roofs, landings, balconies and access platform. 712 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 713 12mm cement plaster on rough side of single or half brick wall mix 714 1:3 (1 cement : 3 Coarse sand) 715 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 716 With 20x20mm square bar 717 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 718 M.D. -10- Circular shape 500mm internal diameter 719 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 720 Drilling of 300mm dia bore hole manually. 721 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 722 150 mm nominal size dia 723 Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 724 Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 725 Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. 726 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 727 DESILTING CHAMBER 728 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 729 In all kind of soil upto 1.5m depth 730 In all kind of soil upto 1.5m to 3.0m. depth 731 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 732 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 733 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 734 Suspended floors, roofs, landings, balconies and access platform. 735 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 736 15mm cement plaster on rough side of single or half brick wall mix 737 1:3 (1 cement : 3 Coarse sand) 738 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 739 With 20x20mm square bar 740 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 741 M.D. -10- Circular shape 500mm internal diameter 742 COST OF EACH RAIN WATER HARVESTING 743 TOTAL NO. OF RAIN WATER HARVESTING 744 TOTAL COST OF RAIN WATER HARVESTING 745 DRAINAGE NETWORK 746 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 747 up to 1.50 m depth 748 Pipes 80 mm to 300 mmdiameter 749 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 750 150 mm.dia. RCCPipes 751 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 752 150 mm. dia. 753 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 754 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 755 Drain 300 wide average.Depth 45 cm with R.C.C. slab 756 INTERLOCKING PATHWAY (283 Sqm) 757 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil (D.S.R. 2.8.1) 758 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (D.S.R. 4.1.8) 759 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 760 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 761 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 762 TRIMIXING FOR PARKING AREA 184.98 SQM 763 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 764 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 765 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finishedwith screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specificationsand directions of Engineer-in-charge. Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately (DSR-16.75) 766 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade A sealing compound. DSR- 16.46.1 767 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.[ DSR 5.22.6 ] 768 BORING & SUBMERSIBLE PUMP 769 Drilling of 200 mm dia bore hole. 770 Supply of 125 mm dia MSpipe as per IS1239 771 Supply of 125 mm dia slotted MSpipe 772 Supply and fixing of nylon jali around the slotted pipes complete as required. 773 Providing and packing of coarse sand / pea gravel around the pipe. 774 Transport of boring tools other required equipements and installation at site. 775 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 776 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 777 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 778 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 779 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 780 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 781 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 782 Testing and development of tube well. 783 HORTICULTURE 784 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 785 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 786 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 787 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 788 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 789 Rough dressing the trenched ground including breaking the clods. 790 Fine dressing the ground 791 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 792 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 793 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 794 With grass Turf 795 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 796 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 797 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 798 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 799 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 800 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 801 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 802 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 803 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 804 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 805 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 806 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 807 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 808 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 809 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 810 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 811 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 812 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 813 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 814 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 815 GST Extra As per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
36.
Public Administrative Department #9363422 Technical Bid
Invites bidder for 1.25 MW online solar power generation for tirth kshetra parli which includes erecting, installing and commissioning of solar panels with below details and specifications and1000 lit solar water heater for tirth kshetra parli which includes erecting, installing and commissioning of solar water heaters with below details and specifications For Non SSR Rate For M C Parli V- 1 Content WritingThe creative writing scope involves the development of narrative content through a structured yet flexible process. It begins with research—supported by books, references, and site visits—and moves through data collection, selection, and consultation with a panel of relevant authorities. The aim is to ensure cultural relevance, thematic consistency, and creative integrity. A team of experienced writers, including those with a background in show and screenplay writing, will lead the storytelling process. The primary writer must have substantial experience—preferably over 15 years— and good credentials in show writing, with a proven ability to handle complex, multimedia-driven narratives. The story evolves into script and screenplay formats, including a technical timeline version to align with visual and sound elements. If musical components are included, lyrics will be written by a professional lyricist with experience in both films and live performances. Dialogue writing, idea translation, and screenplay adaptation into other languages are also part of the scope, overseen by a dedicated language supervisor to ensure linguistic clarity and cultural sensitivity. While certain elements may adapt during the creative cycle, the process will remain focused on delivering a cohesive, original, and production-ready script. The show will be bilingual.The job consists of - Data Collection, Data Selection, Authority team, Creating Ideas, Story writing, Script Draft, Screenplay, Lyric writing, Dialogue writing, Technical timeline Screenplay, Translating ideas, Translating Screenplay, Language Supervison 2 DubbingThe audio production scope includes all processes related to voice recording, dubbing, and language adaptation as required for the project. The process begins with planning and coordination under the supervision of a Creative Director, in consultation with the script and language teams. Dubbing forms the core of the audio workflow. This includes recording of voiceovers and dialogues by both celebrity artists and junior artists, as per casting decisions. Talent coordination, scheduling, and handling of logistics fall under the purview of the Artist Management team, which ensures seamless execution across sessions. All voice recordings will be carried out at a professional audio studio, equipped to handle multichannel dubbing and real-time monitoring. Sessions are overseen by an experienced Dubbing Director, responsible for voice performance quality, tone accuracy, and delivery consistency across versions. Throughout the dubbing phase, a language supervisor ensures linguistic correctness, pronunciation alignment, and translation fidelity—particularly in multilingual productions. Supporting staff, including a designated assistant, will aid in session coordination, script handling, and communication between departments. This is a bilingual project. While the structure of the recording process is generally predefined, flexibility may be exercised based on artist availability, script revisions, or project-specific creative needs. 3 The background music The background music production covers the complete creation of an original score to support the overall mood and narrative of the show. The process is led by a Music Director, assisted by a dedicated assistant, and involves contributions from a Music Arranger and music programmers who develop the structure, orchestration, and digital elements of the composition. Live elements are performed by instrument players and chorus singers, as required by the arrangement. To enhance realism and support on-screen action, foley artists are engaged for the creation of natural, synchronized effects. All music components are recorded in a professional audio recording studio, with the final mix executed in a 7.2 surround sound mixing studio to ensure high-quality, immersive output. While the structure is generally predefined, certain creative decisions may adapt during the process to meet evolving artistic and technical needs. 4 Creating songs- The music production scope for songs includes composition, arrangement, recording, and mixing of original tracks suited to the narrative and emotional context of the project. The process is led by a Music Director, responsible for the overall musical vision, supported by an assistant who coordinates sessions and logistics.A Music Arranger refines the musical structure, harmonies, and instrumentation, while music programmers handle sequencing, layering, and digital sound elements. Instrument players contribute live performances to add depth and authenticity to the arrangement. The vocal component features celebrity singers, selected for their voice quality and public resonance, supported by chorus singers where needed for harmony or scale.All vocal and instrumental recordings are conducted in a professional audio recording studio, equipped for multi-track sessions. The final output is processed and balanced in a 7.2 surround sound mixing studio, ensuring spatial clarity and production-grade sound. Adjustments may be made during the creative process to accommodate performance styles, technical feedback, or evolving project direction. 5 Audio MixingThe final audio mixing phase ensures the integration and balance of all sound elements—dialogue, music, effects—into a polished, immersive audio output. The process is creatively led by a Creative Director, who provides the overall aesthetic and emotional direction for the final sound. A designated assistant coordinates schedules, handles version tracking, and supports communication between departments to maintain workflow efficiency. The mixing is executed in a professional 7.2 surround sound studio, equipped for spatial sound design and high-fidelity output suitable for large-format or immersive playback environments. It is a bilingual Production A Technical Supervisor oversees the process, ensuring all specifications related to format, levels, and playback compatibility are met, while also maintaining quality control across multiple output versions.Final adjustments may vary depending on the nature of the content and platform-specific requirements. 6 Scope for Bilingual -The scope includes complete audio localization of the project into a second language, covering dubbing, background music, and song music production. The process begins with dubbing, involving voice recordings by native-speaking celebrity and junior artists, directed by an experienced Dubbing Director under the creative guidance of the Creative Director. Sessions are conducted in a professional audio studio, with oversight from a Language Supervisor to ensure linguistic accuracy and cultural relevance.The background music is either adapted or recreated to suit the tonal needs of the second language version. This includes re-arrangement, possible re-recording by instrument players, and adjustments led by the Music Director with support from arrangers and programmers. Where applicable, song music production is carried out in the second language, featuring celebrity singers and chorus artists, ensuring lyrical integrity and emotional alignment. Lyrics are adapted and approved by the language and creative teams to retain the original intent while fitting the new languages phonetic and rhythmic structure. All elements—dialogue, music, and effects—are finally mixed in a 7.2 surround sound studio under the supervision of a Technical Supervisor, ensuring cohesion and broadcast-ready quality. Some creative or technical modifications may be made based on language-specific needs or audience expectations. 7 Indoor ShootingThe indoor studio shoot covers all aspects of video production carried out within a controlled studio environment, under the overall vision of the Creative Director. The shoot is planned and executed with the support of a technical supervisor, assistant, and a full production team, ensuring that both creative and logistical aspects are effectively managed.The cast includes celebrity artists and junior artists, whose schedules and coordination are handled by the artist management team. Performance delivery is supported with tools such as a teleprompter and direction provided on set. The production takes place in a professional video studio using high-grade camera equipment, with visuals led by a skilled Director of Photography (DOP). The setup includes a full lighting rig, supplemented by a generator for uninterrupted power supply. For shoots requiring virtual backgrounds or visual integration, chroma key technology is used. Supporting elements include on-location sound setup, makeup, costumes, and props, all arranged to maintain visual consistency with the creative concept. The location and studio logistics are prepared in advance, ensuring readiness for smooth execution. While most elements follow a predefined structure, flexibility is maintained for creative changes, technical adjustments, or talent-related considerations during the shoot. 8 Outdoor ShootingThe outdoor location shoot involves the execution of video production in open, uncontrolled environments, led creatively by a Creative Director and technically coordinated by a Technical Supervisor with support from an Assistant and a full Production Team. This setup ensures both the creative vision and the operational logistics are effectively managed on site.Camera equipment and on-location filming are handled by an experienced Director of Photography (DOP), supported by a custom lighting setup and reliable power supply through generators. The presence of junior artists, along with complete makeup, costumes, and props, helps bring the narrative elements to life during the shoot. To capture wide and aerial perspectives, a drone camera is operated by a trained drone operator, enabling cinematic coverage of the location. On-site sound setup ensures proper dialogue and ambient recording despite outdoor challenges. Comprehensive logistical support is included, covering crew transport, food, and accommodation, ensuring the teams comfort and efficiency during extended schedules. Outdoor management costs account for location permissions, crowd control, weather-related support, and other unforeseen field requirements. While the shoot is planned in detail, flexibility is maintained to adapt to on-site conditions, natural light changes, or last-minute creative directions. 9 Editing The editing phase involves assembling, refining, and finalizing the visual and audio content using professional software platforms such as FCP or Premiere. The process is led by a skilled Editor, working under the creative guidance of the Creative Director, and supported by an Assistant for logistical and coordination tasks. A Technical Supervisor ensures compatibility across formats and monitors workflow consistency. The edit includes detailed color correction and DI (Digital Intermediate) processing to ensure visual consistency, mood enhancement, and output readiness for multiple formats.Simultaneously, sound matching is carried out to align the audio precisely with visual elements, ensuring a seamless viewing experience. While the process follows an established structure, creative and technical adjustments may be made during post-production based on evolving requirement. 10 The concept development The concept development stage lays the foundation for the animation project by defining the core theme, narrative, or message to be communicated through the visual content. This includes interpreting the shows objective and aligning it with the desired emotional, cultural, or historical tone.A clear understanding of the events context—its purpose, audience, location, and scale—is essential at this stage. This helps shape the visual language, pacing, and symbolic elements of the animation. In parallel, the creative team gathers necessary architectural references, including blueprints, elevations, or high-resolution photographs of the projection surface—such as a building façade, monument, or custom structure. These assets are critical for mapping visual content accurately and ensuring that the animation interacts naturally with the physical form of the structure. This stage may involve creative exploration, mood boarding, and draft scripting, with room for refinement based on client input or site-specific constraints. 11 The projection surface analysisThe projection surface analysis phase focuses on the detailed study of the building or structure intended for projection. This includes analyzing its dimensions, contours, architectural features, and physical obstacles such as balconies, columns, or surface irregularities that may impact visual output.Based on this analysis, the team develops a precise 3D model or high-fidelity mock-up of the actual building or façade. This model serves as the reference framework for animation alignment, ensuring that visuals map seamlessly onto the surface and interact accurately with its physical geometry. This step is essential for delivering a high-impact, distortion-free projection experience. 12 The Storyboard & Visual ScriptingThe Storyboard & Visual Scripting phase involves planning the sequence of visuals, defining key scenes, transitions, and impactful moments that shape the overall flow of the animation. This step establishes the visual rhythm and narrative structure of the show. A detailed visual script is developed alongside the storyboard, mapping out how each visual element aligns with music, voiceover, or narration, if applicable. This ensures creative cohesion between the audio and visual components, serving as a blueprint for the animation and production teams during the execution phase.The Asset Creation phase The Asset Creation phase focuses on designing and developing all visual elements required for the animation. This includes creating characters, environments, and props using industry-standard 3D software such as Blender, Maya, or Cinema 4D, depending on project needs. In addition to modeling, the team creates or sources textures, lighting references, and visual effects that enhance the realism or stylistic tone of the animation. These assets form the visual foundation of the project and are tailored to suit the projection surface, storytelling requirements, and overall design direction.The 3D Animation & SimulationThe 3D Animation & Simulation phase involves animating visual elements in precise synchronization with the storyboard and audio, including music, narration, or sound design. This ensures that the visuals follow the intended rhythm and narrative structure. The process includes the addition of dynamic visual effects such as explosions, transformations, morphing, and architectural illusions to enhance the visual experience and create dramatic impact. To complement the content and surface geometry, camera movements and spatial transitions are simulated within the 3D environment, ensuring smooth visual flow and accurate alignment with the unique structure of the projection facade. 13 The RenderingThe Rendering phase involves generating the final animated output in high resolution (typically 4K or higher) to meet the technical requirements of the projection system. This step ensures that all visual elements are produced with maximum clarity and detail.Special attention is given to color accuracy, brightness, and contrast levels, The Audio Synchronization The Audio Synchronization phase involves the mixing of background music, voiceovers, and sound effects (SFX) into a cohesive audio track. This mix is carefully aligned with the visual timeline to ensure seamless integration.Key sound cues are timed precisely with visual events to enhance dramatic impact and emotional engagement. The synchronization process ensures that audio elements not only support but elevate the overall viewing experience.Calibration -The Projection Mapping & Calibration phase focuses on aligning the final animation with the architectural surface using specialized software such as MadMapper, Resolume Arena, or HeavyM. This step ensures that the visual content fits precisely to the buildings structure and features.On-site testing is conducted using actual projectors to fine-tune the mapping. The Final Testing The Final Testing & Show Execution phase involves conducting full-scale tests of the complete animation and audio sequence under actual or simulated show conditions, typically at night to match final lighting environments. This ensures accurate visual impact and technical performance. During testing, the team performs final adjustments to fine-tune synchronization, alignment, and timing across projection, sound, and control systems. All critical elements—transitions, cues, and effects—are reviewed for precision.Comprehensive backup systems are prepared, and the triggering mechanism for the show is tested for seamless execution and reliability, ensuring a smooth and uninterrupted live experience. 14 Concept & Theme DevelopmentThis stage involves identifying the purpose of the show—such as entertainment, branding, or cultural celebration. It includes defining the narrative structure, key visual highlights, and emotional peaks. Visual elements will be carefully aligned with music, narration, or other media components to create a cohesive and engaging experience. 15 Site Analysis & Safety PlanningSite Analysis & Safety PlanningIncludes a detailed survey of the venue to assess dimensions, audience layout, and whether the space is indoor or outdoor. Identifies laser-safe zones and ensures compliance with relevant safety standards. Plans for environmental factors such as wind, dust, reflective surfaces, and addresses power supply and equipment placement needs.Storyboard & Laser DesignInvolves creating a detailed show flow with defined cues for anim+B27ations, effects, and transitions. Includes the design of laser scenes incorporating elements such as text, logos, line art, tunnels, waveforms, and abstract visuals to match the overall narrative and theme.Audio IntegrationInvolves selecting or composing a soundtrack that enhances the laser visuals. Visuals are precisely synchronized to musical beats and cues using timeline-based software to ensure a cohesive and impactful audiovisual experience. 16 Programming the Laser ShowUtilizes specialized software (e.g., Pangolin Beyond, Laser Show Designer, LSX) to design and animate laser graphics. Involves programming scene cues with precise timing, color modulation, and optimizing vector paths to reduce flicker and ensure clean, stable laser projections.Equipment SetupInvolves integration of the control system using a laptop, DMX interface, or timecode-based triggering setup to ensure reliable playback and synchronization of laser and show elements.Show ExecutionInvolves synchronizing the laser show with other elements such as music, lighting, and pyrotechnics. Cues are triggered manually or through automated systems using timecode or MIDI. Real-time monitoring is performed to ensure system performance and maintain audience safety. 17 Objective & Concept DevelopmentDefines the purpose of the lighting design—whether for concerts, architectural highlights, theatrical performances, or event ambiance. Focuses on understanding the emotional tone, thematic direction, and desired audience impact. A creative lighting concept is developed to support the narrative, brand identity, or spatial transformation goals.Venue Analysis & Technical SurveyInvolves assessing the venues dimensions, architectural features, and ambient lighting conditions. Identifies available power sources, rigging points, and spatial limitations such as stage size and ceiling height. A 3D model or detailed layout is created or requested to aid in accurate previsualization and planning.Mood Board & Visual ReferencesCurates visual references for color schemes, lighting styles, fixture types, and integration with stage or set design. A mood board is developed to reflect the artistic direction and align with the client’s brief and creative vision.Lighting Plot & Fixture PlanningInvolves selecting suitable light fixtures such as washes, spots, beams, strobes, LED bars, and moving heads. Plans fixture positions and focus angles on a detailed lighting plot. Assigns control channels, fixture groups, and zoning to ensure efficient programming and operation. 18 Programming & Cue DesignUtilizes professional lighting control software (e.g., GrandMA, Chamsys, Avolites) to program show cues. Lighting sequences are synchronized with music, movement, or stage actions. Includes design of layered transitions such as dimming, color changes, fades, strobes, and dynamic fixture movements.Previsualization & RenderingSimulates the lighting design in 3D environments using tools such as Capture, WYSIWYG, or Depence². Provides rendered images or video previews to the client and production team for review, feedback, and approval prior to on-site setup.On-site Setup & RiggingInvolves coordination with the technical crew to install lighting fixtures, cabling, and rigging infrastructure. Includes focusing lights and adjusting beam angles, sizes, and positions. All units are tested for power, DMX signal integrity, and proper alignment.Rehearsals & Final ProgrammingConducts full run-throughs with live sound, performers, or projected content to validate timing and coordination. Adjusts cue timings, fade curves, and brightness levels based on actual venue conditions. Finalizes and programs the cue stack for show triggering via manual control, timecode, or live operation. 19 Show Planning & Cue BreakdownDefines all technical and creative elements involved in the show, including lighting, video projection, lasers, sound, pyrotechnics, and moving set pieces. Breaks the show into cue points based on timeline, music, or script structure. Timeline & Control System SelectionDetermines the central control method for the show—timecode-based, cue-stack driven, or a hybrid of manual and automated triggers. Selects appropriate software and hardware solutions (e.g., QLab, Timecode Buddy, Watchout, Medialon, Disguise, TouchDesigner, Hippotizer, MADRIX, Reaper). Defines communication protocols such as MIDI, DMX, OSC, TCP/IP, or Art-Net for seamless integration between devices.System Integration & Communication SetupEnsures all show systems—including lighting, video, audio, and mechanical elements—are networked and properly addressable. Sets up protocol routing, such as MIDI triggers for video playback or SMPTE timecode for synchronizing lighting and audio cues. Configures master/slave relationships to establish a reliable sync hierarchy, typically with audio as the master clock. 20 Programming Cue SequencesDevelops a detailed cue list within the control software, assigning precise timings and smooth transitions for each element. Triggers are programmed to execute specific actionsPrevisualization & TestingUses specialized software (e.g., Disguise for video, Capture for lighting, TouchDesigner for interactive elements) to s+B48imulate the full cue stack in a virtual environment. Enables fine-tuning of transitions, timing, and synchronization across systems before on-site setup, helping to identify and resolve potential issues in advance.Rehearsal & On-Site CalibrationConducts full rehearsals using actual show hardware including lighting rigs, projectors, audio systems, and stage mechanics. Fine-tunes cue timings, fade curves, and mechanical movements to match music or video beats. Tests all failsafes, aligns system triggers, and ensures timecode sources are synced with acceptable playback latency across all systems. 21 Digital signal processor - 12 x 8 Networked Digital Signal Processor with 12 inputs and 8 outputs or more; 12 ormore Control Inputs and 6 or more Logic Outputs for GPIO Integration; 48V phantom power on all analog inputs; THD: <0.01% 20Hz to 20KHz; Crosstalk: <-75dB orbetter; Open architecture software configurable; logic processing power; 2 digital audio bus RJ45 Port; 1Ethernet RJ45 port for Monitoring and configuration; Capable to handle +5V unloaded logic output voltage; Should have speech sense engine; Capable to control 3rd party devices with TCP IP and RS232; Should have 1nos of RS 232 port for integration with control System; Should have Bi-Directional Locate Functionality; Should have 48 or more digital audio Channel Bus; Should have monitoring LED for COM, STAT, ERR and PWR; etc.Approved Make: BSS / bi-amp / Symetrix 22 Wall Mount Controller - 8 Buttons Ethernet Controller and Volume Control, Should be Compatible with supplied DSP, Should support PoE (Power Over Ethernet), 8 Programmable Buttons (Multicolored), Capable to trigger any DSP logic, Multicolored 2 Programmable 64x128 Pixel LCDs, Sleep Function, Security: Remote Lock/Unlock and Local Unlock via PIN Entry, Should have knob and capable to control 8 zones separate.Approved Make: BSS / bi-amp / Symetrix 23 Wall mount arrayable speaker.High Power 3-Way Loudspeaker with 15 LF; Frequency Response:(±3 dB): 45 Hz – 18 kHz, Frequency Range (-10dB):38Hz – 20KHz; Coverage Pattern: 90° x 50°, rotatable waveguide, Crossover Modes: Tri-amp/Bi-amp switchable, Transducer Power Rating :LF 4000 W peak , MF 1400 W peak ,HF 400 W peak, LF Driver : 15”; MF Driver : 8” ; HF Driver : 1.5”; Sensitivity LF : 97dB; Sensitivity MF: 108dB; Sensitivity HF: 115dB;Maximum SPL: LF:133 dB peak , MF/HF: 139 dB peak, ; Nominal Impedance: 8 ohms, Grille: Powder coated 14 gauge perforated steel, Enclosure: Trapezoidal with 15 degree side angles.Approved Make: JBL / L-acoustic / d&b audiotechnik 24 Weathrised SpeakerHigh Power 3-Way Loudspeaker with 15 LF; Frequency Response:(±3 dB): 45 Hz – 18 kHz, Frequency Range (-10dB):38Hz – 20KHz; Coverage Pattern: 90° x 50°, rotatable waveguide, Crossover Modes: Tri-amp/Bi-amp switchable, Transducer Power Rating :LF 4000 W peak , MF 1400 W peak ,HF 400 W peak, LF Driver : 15”; MF Driver : 8” ; HF Driver : 1.5”; Sensitivity LF : 97dB; Sensitivity MF: 108dB; Sensitivity HF: 115dB;Maximum SPL: LF:133 dB peak , MF/HF: 139 dB peak, ; Nominal Impedance: 8 ohms, Grille: Powder coated 14 gauge perforated steel, Enclosure: Trapezoidal with 15 degree side angles.Approved Make: JBL / L-acoustic / d&b audiotechnik 25 Subwooferhighpower install grade Dual 18 low frequency loudspeaker systemwith extended frequency range with mounting points for OEM hardware/ bracket. Frequency response: 20Hz to 1KHz (-10 dB) or better, Power rating: 2400W continuous or better; Sensitivity: 99dB or better; Maximum SPL: 135dB or better; Nominal Impedance: 4ohm in parallel and 2X8 ohm in driver mode; LF Driver 18 or better; LFdriver with 4 voice coil.Approved Make: JBL / L-acoustic / d&b audiotechnik 26 Digital Power AmplifierFour channel Digital Network Based Power Amplifier with Power output 4 x 2400W @ 4 Ohms / 8 Ohms; should support 70Vrms and 100Vrms output on all output channels; THD 0.35% or better; Should support Cooling Continuously variable speed forced air; Voltage Gain 34dB or more; Digital bus compatibility up to 8 or more audio channel; bridgeable channels - even in 100Vrms mode for 200Vrms Output; 2digital audio bus RJ45 port; 1 Ethernet R 45 port for monitoring and configuration;Should have DSP features incl. Limiters , Input/output EQ ,Delay ,Matrix Mixer ,Speaker Line Monitoring; Damping Factor (20 Hz to 100 Hz) : >5000 or more; etc.Approved make: Crown / RAM Audio / Labgrupen 27 Digital Power AmplifierMultichannel Digital Network Based Power Amplifier with Power output 4 x 1250W or better @ 4 Ohms / 8 Ohms; Should support 70Vrms and 100Vrms output on all output channels; THD 0.35% orbetter; Cooling Continuously variable speed forced air; Voltage Gain 34dB ormore; Digital bus compatibility up to 8 or more audio channel; bridgeable channels even in 100Vrms mode to operate with 200Vrms output; 2digital audio bus RJ 45 port; 1 Ethernet R 45 port for monitoring and configuration; Should have DSP features like Limiters , Input/output EQ , Delay ,Matrix Mixer ,Speaker Line Monitoring; Damping Factor (20Hz to 100Hz) : >1500 ormore; etc.Approved make: Crown / RAM Audio / Labgrupen 28 Digital Power AmplifierMultichannel Digital Network Based Power Amplifier with Power output 4 x 600W @ 4 Ohms / 8 Ohms or better; Should support 70Vrms and 100Vrms output on all four channels; Frequency Response: ±0.25dB or better; Total Harmonic Distortion: 0.35% or better; Voltage Gain: 34dB or better; Damping Factor(20Hz to100Hz): >1000 or better; Signal to Noise Ratio: >108dB or better; Cooling: Continuously variable speed forced air, front to back airflow; bridgeable channels even in 100Vrms mode to operate with 200Vrms output; 2digital audio bus RJ 45 port; 1 Ethernet R 45 port for monitoring and configuration; Should have DSP features like Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring.Approved make: Crown / RAM Audio / Labgrupen 29 Digital Power AmplifierMultichannel Digital Network Based Power Amplifier with Power output 8 x 300W @ 4 Ohms / 8 Ohms or better; Should support 70Vrms and 100Vrms output on all Eight channels; THD 0.35% or better; Damping Factor (20 Hz to 100 Hz): >1000 or better; Frequency Response: ±0.25dB or better; Signal to Noise Ratio: >108dB or better;Cooling: Continuously variable speed forced air, front to back airflow; Voltage Gain: 34dB or better; Audio Digital channel bus compatibility up to 8 channel, bridgeable channels - even in 100Vrms mode, 2 digital audio bus RJ 45 port, 1 Ethernet R 45 port for monitoring and configuration, Should have Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring.Approved make: Crown / RAM Audio / Labgrupen 30 Stage Monitors 1 x 12 LF; 2-Way Stage Monitor Speaker System; Power Rating 300W at 8 Ohms; etc.Approved Make: JBL / L-acoustic / d&b audiotechnik 31 2.5 sq mm multi stranded speaker cable 32 1.5 sq mm copper multi strandedcable 33 2 core shielded 23/36 cable 34 XLR connector 35 Speak on male and female connector 36 Jack Pins 37 RC Pins 38 EP pins 39 18U audio RackBrand - ‎RIVECO / Manufacturer - ‎RIVECO / Model - ‎OF5518 / Model Name - ‎OF / Product Dimensions ‎55.12 x 50.04 x 90.17 cm; 12.25 kg / Item model number ‎OF5518 / Compatible Devices - ‎Server / Material- ‎Alloy Steel / Manufacturer - ‎RIVECO Item Weight- ‎12 kg 200 g 40 Analog Mixer – 10-channel mixing console with 4 mono mic/line inputs featuring D-PRE Class-A preamps, +48V phantom power, one-knob compressors, 3-band EQ, high-pass filters, and 3 stereo line inputs; integrated SPX digital multi-effects processor with 24 presets; built-in 24-bit/192kHz USB audio interface (2-in/2-out); balanced XLR and TRS main outputs, monitor out, FX send, and headphone output; rugged metal chassis (244 x 71 x 294 mm, approx. 2.1 kg); includes external PA-10 power supply. Suitable for professional live sound and studio recording applications.Approved Make - Yamaha, Mackie, Beheringer 41 Microphone (with cable) – Dynamic cardioid vocal microphone designed for professional live vocals and studio use, featuring a tailored frequency response of 50 Hz to 15 kHz for clear vocals and speech, uniform cardioid pickup pattern for excellent off-axis rejection, pneumatic shock mount system to reduce handling noise, built-in spherical wind and pop filter, rugged steel mesh grille, and durable metal construction; output impedance of 150 ohms, sensitivity of –54.5 dBV/Pa (1.85 mV), and XLR 3-pin connector.reliable, clarity, and stage durability.Approved Make - Shure, Sennheiser 42 Microphone Stand – Heavy-duty, adjustable-height microphone stand with tripod base or round base options, suitable for studio and stage use; features height adjustment clutch, extendable boom arm (where applicable), and standard 5/8 mic thread mount. Recommended brands: K&M (König & Meyer), Hercules, QuikLok, Samson, and Maplin. Ensure compatibility with dynamic and condenser microphones for versatile application 43 Installation, Testing & Commissioning of Sound System – Involves installation of speakers, mixers, amplifiers, processors, microphones, and cabling as per design; proper mounting, wiring, and termination with safety and signal integrity checks; system calibration including level setting, equalization, and time alignment; verification of all input/output signal paths; integration with AV or control systems if required; conducting performance tests to ensure clarity and coverage; final tuning, user orientation, and handover of a fully functional audio system. 44 Image - brightness (lumens) - • 17,800 ISO /15,000 ANSI • 23,750 ISO /20,000 ANSI color wheel• 4 segment – 3X speedDisplay technology - type - 1 x 0.8 HEP DMDresolution - WUXGA • 1920 x 1200 (2,304,000 pixels) (16:10)Illumination - type - High efficiency blue laser phosphor / performance, 20,000 hours to 50% brightness at full power mode, 50,000 hours to 50% brightness at ECO1 modeSignal Inputs - standard - HDMI 2.0b x 2 (HDCP 1.4/2.2) • 3G-SDI x 1 (BNC) -Display Port x 1(1.2a) • USB 2.0 x 1 (Type A) • HDBaseT - 1.0 (RJ45) x 1signals - Horizontal and vertical scaling while maintaining aspect ratio (all inputs)3D-Active shuttered - HDMI 1.4, HDBaseT – frame packing, top/bottom, side-by-side at 1080p at 60Hz frame sequential WUXGA(RB) up to 120 Hz. - 3D sync in (BNC) – for genlocking 45 projectors - 3D sync out (BNC) – for genlocking projectors, or controlling emitter or polarizerpixel clock - 600MHzscan rates - Horizontal: 15.375 kHz ~ 135.0 kHz ; Vertical: 23.98 Hz ~ 120 Hz -Signal Outputs monitor out (loop-through) - 3G-SDI x 1 (BNC) • HDMI x 1 (HDMI out)Control and networking -HDBaseT (RJ45 x 1) /RJ45 x 1 (Ethernet Control over wired network connection) / RS232 x 1 / Remote in: 3.5mm stereo female (provides serial communications and power) / DC JACK 12 VDC, 200 mA maxTAA-compliant - Yes 46 Lenses - mount type - Boresight adjustable - Motorized horizontal and vertical lens offset (memory available) / Motorized zoom and focus adjustment (memory available for full ILS lenses)lens options - 0.46:1 UST lens - • 1.8-2.4:1 zoom lens • 2.4-4.8:1 zoom lens • 4.8-8.64:1 zoom lens • 8.64-12.96 zoom lensAccessories - standard - IR remote with wired remote jack (wire not included) • AC line cord for projector • Product Safety Guide 47 Installation testing and comminssioning -Includes unloading, positioning, and secure rigging or ceiling/truss mounting of high-lumen projectors as per projection plan; connection of power supply, signal inputs (HDMI, SDI, DVI, DisplayPort, or HDBaseT), and control interfaces (LAN, RS232, or remote protocols); alignment of projectors with screen surfaces or projection areas using lens shift, zoom, and keystone adjustments; implementation of edge blending, warping, and soft/hard masking where multiple projectors are used; calibration for brightness, color uniformity, and geometry using test patterns or software tools; full testing for input responsiveness, synchronization with lighting/audio cues, and heat management; integration with media servers, automation or timecode systems; final run-throughs and commissioning for stable operation and visual consistency during the show. 48 The PAR 180 RGBW IP is a powerhouse in the realm of LED lighting. Boasting 54X3W RGBW LEDs, it offers a vibrant array of colors with precision. Constructed with robust die-cast aluminum housing and an efficient heat sink, it ensures durability and minimal power consumption. Its slim profile accommodates five lens angle options, providing flexibility for various lighting applications. Whether for professional setups or outdoor events, this PAR delivers reliability and versatility in every illumination.Voltage - AC115-230V, 50/60 Hz / Power120W / Lamp source 54X3W RGBW 6000K Life / Color temperature / time 80000h / Lens angle15/25/20/45/60 ° / Channel 4/8 CH / Control mode DMX512, master-slave, auto, sound control / IP Rating IP65 / Net Weight 5.5 KG / Gross Weight 12.6 KG (Cardboard packing 2in1) / Package 60 X 30 X 33 CM (Cardboard packing 2in1) 49 Moving Heads - Rainbow 300:- Model No. :-11001001 Lamp Type :- Philips MSD 250W / Osram HRI 251W ,Average Life :- 1500 hours ,Color Temperature :- 7800K / 7890K ,Reflector :- Lamp and reflector combined in one unit ,Lens :- High-precision optical lens ,Beam Angle :- 0°–4° ,Color Wheel :- 13 Color Filters + Open ,Effects :- Rainbow effect can be created ,Gobos :- 12 Fixed Gobos + 4 Glass Gobos + Open ,Effects :- Shake effect,Frost Effect :-Independent frost soft effect,Dimming :- Mechanical linear 0–100% dimming ,Strobe Effects :-Fast strobe, pulse / asynchronous / synchronous / random speed ,Prism Wheels :- 3 Total: • 1 x 8+8+8 Honeycomb Prism (Self-rotating) ,• 1 x 8 Circular Prism (Self-rotating) ,• 1 x 8+16 Facet Circular Prism ,Optional Prism :-6 Facet Linear Prism,Total Prism Effects :- 7 ,Pan Range :- 540°,Tilt Range :-270° ,Reset System :-Electro-optic auto-reset system ,Control Channels :- 16CH / 20CH ,Control Modes :-DMX512, RDM (Optional), Auto Run, Sound ,Addressing Option :-Type-C Socket (Powerbank compatible) ,Menu Display :-LCD with 16 million pixels, 180° rotatable,Fan Control :- Intelligent fan control ,Sensor Detection :- Electronic sensor detection ,DMX Monitoring :- DMX control monitor,Motor Drive :- X/Y Two-phase motor drive,LCD Features :- Parameter query available 50 Moving Heads - Rainbow 600 (Wall washer) ,Model No. :-11001021 ,Lamp Type ,OSRAM HRI 420W / Philips MSD 420W ,Average Life :- 2500 hours ,Color Temperature :- 7600K / 8000K .Reflector :- Lamp and reflector combined in one unit , Lens :- High precision optical lens ,Beam Angle :-2.8° ,Color Wheel :-14 Color Filters + Open,Effects :- Rainbow color effect ,Gobos:- 12 Fixed Gobos + 4 Glass Gobos + Open ,Effects :-Shake effect,Frost Effect :-Independent frost soft effect ,Dimming:- Mechanical linear 0–100% dimming ,Strobe Effects :-Fast strobe, pulse / asynchronous / synchronous / random speed ,Prism Wheels :-2 Total: :-• 1 x 8+8+8 Honeycomb Prism (Self-rotating) ,• 1 x 8 Facet Circular Prism (Self-rotating) ,Total Prism Effects:- 3,Pan Range :- 540° ,Tilt Range :- 270° ,Reset System :- Electro-optic auto-reset system,Control Channels :- 16CH / 20CH ,Control Modes :-DMX512, RDM (Optional), Auto Run, Sound ,Addressing Option :- Type-C Socket (Powerbank compatible),Menu Display :-LCD with 16 million pixels, 180° rotatable,Voltage :- AC100-240V 50/60Hz,Ballast :- Electronic ballast ,Power Consumption :- 600W,Clamp Type:-Inbuilt folding clamp ,Product Dimensions :-38 x 32 x 66 CM,Net Weight :-20KG,Flight Case Packaging (2 in 1):-78.5 x 46 x 89.5 CM ,Gross Weight :-60KG 51 DMX Spliter 8C :- Take control of your lighting rig with the DMX SPLITTER 8CH 2 IN1. Amplify your DMX signal to four independent outputs, providing greater fixture control and scalability for large-scale events and intricate lighting designs. With impeccable signal integrity and flexible configurations, this splitter is the perfect choice for demanding outdoor environments, touring artists, and rental companies seeking reliable performance and stability.Power input :- AC120V-240V 50Hz/60Hz ,Consumption :-20W ,Net Weight :- 2.4 KG,Gross Weight :- 14 KG ,Cardboard packing :- (5in1),Package :- 51X24X48 CM 52 Haze :-DFZ-2100 is a top of the range water-based haze machine designed for the professional market. It has strengthened its performance than its predecessor, comes built-in flight case and can be stacked one on another. DFZ-2100 haze machine features a unique heating system which enables to produce continuous even haze, free from clogging, reduce maintenance and extend product life. Operating at low noise levels makes it an ideal choice for noise-sensitive environments, including theaters, stages, studios and high-end bars.,Power :-1200W ,Voltage:- AC220V-240V/50-60Hz .Warm-up time :- Appr. 2 Min,Fuel consumption :-83 Min/L ,Tank capacity:- :-5 ltr. ,Max output volume:- 12000 cuft / Min,DMX Channel :-2,DISPLAY :-LCD-2,Net Weight :- 14 KG , Gross Weight ,16 KG ,P Dimensions :- 51×39×26.5 CM ,C Dimensions:- 59×47.5×33.5 CM 53 Cables:- 2.5 sq mm cable 54 Connectors -Includes supply and installation of professional-grade connectors for stage lighting such as XLR (3-pin/5-pin) for DMX signal, PowerCON and True1 for secure power connections, and EtherCON for network-based lighting protocols like Art-Net or sACN; all connectors to be heavy-duty, locking type, and suitable for touring or fixed installations, ensuring reliable signal transmission, power safety, and system durability; recommended brands include Neutrik, Amphenol, and Seetronic. 55 Poweboard -Custom-designed power distribution board for stage lighting, equipped with industrial-grade MCBs, RCBOs, power indicators, and socket outlets (16A/32A/63A as required); includes multiple protected outputs for connecting lighting fixtures and dimmers, with proper earthing, load balancing, and surge protection; housed in a rugged enclosure suitable for indoor/outdoor use; ensures safe and reliable power supply for all stage lighting equipment; recommended components from brands like Legrand, Schneider Electric, or L&T. 56 Installation - Involves mounting and rigging of lighting fixtures (LEDs, movers, PARs, etc.) on trusses or grids, routing and termination of power and DMX/control cables, addressing and patching of fixtures, integration with lighting console via DMX or Art-Net, testing for power, control signal, and fixture functionality; includes alignment, focusing, and basic programming as per show design; all work to comply with safety standards and rigging best practices. 57 lamp power:- 40W,Laser power :-Red:10000mw Green:15000mw Blue:16000mw ,Power consumption :-760W,Wavelength :-Red:638mw Green:525mwBlue:450mw,Laser source :- Diode(NICHIA) ,Colors :- RGB full color ,External Modulation :-100K Analog, TTL,DMX Channel :- 19CH/32CH,Scanner system :- 50kpps☑,Laser source :- Diode(NICHIA),Colors :-RGB full color, External Modulation :- 100K Analog☑ TTL☑,DMX Channel :-19CH/32CH,Scanner system :- 50kpps 58 Timecode reader for Laser Show – Device used to read and decode SMPTE/LTC timecode signals for precise synchronization of laser projections with audio, lighting, and video cues; ensures frame-accurate playback and seamless integration with laser control software; supports industry-standard timecode formats, offers stable input detection, and is compatible with show controllers and timeline-based systems. Recommended brands -Pangolin, LaserAnimation Sollinger, and Showtacle 59 License Key for Laser Show Software – Official software authorization key required to unlock full features of professional laser show control applications such as Pangolin QuickShow, BEYOND, or Showtacle Moncha.NET; enables access to advanced timeline programming, multi-laser control, DMX/Art-Net integration, 3D animation tools, and real-time synchronization with audio, video, and lighting systems; delivered as a hardware dongle or digital activation key. Essential for legal use and operation in professional multimedia and laser show productions. 60 InstallationIncludes mounting and alignment of laser projectors at designated locations, secure rigging with safety measures, routing and termination of power, signal, and control cables, integration with control systems (DMX/Art-Net/ILDA), installation of safety interlocks and emergency stop switches, basic lens and beam path alignment, and ensuring compliance with safety standards; system tested for alignment, coverage, and synchronization with multimedia content before handover. 61 Server :- Operating System -Windows 10 or Windows 11 (64-bit), macOS 10.15 (Catalina) or later,Processor- Recommended: Intel Core i7 or AMD Ryzen 7, Minimum: Intel Core i5 or AMD Ryzen 5 :- Recommended: Intel Core i7 or AMD Ryzen 7, Minimum: Intel Core i5 or AMD Ryzen 5,Recommended: 16 GB or more, Minimum: 8 GB.Graphics Card :- Recommended: NVIDIA GeForce RTX 4060 with 6 GB VRAM, Minimum: NVIDIA GeForce GTX 960 with 2 GB VRAM,Storage:- Recommended: SSD with 10 GB free, Minimum: 5 GB free space ,Video Inputs :-HDMI x 2 (HDCP 2.2 compliant), DisplayPort x 1 (version 1.2), DVI-D x 1 (digital only), USB x 1 (Type A),Video Outputs :- HDMI x 1, 3G-SDI x 1 (BNC),Optional Video Inputs :- HDBaseT (RJ45 x 1), Terra SDVoE, 3G-SDI x 1 IN (BNC), 3G-SDI x 1 OUT (BNC), WiFi Dongle,Audio Outputs :- Stereo output via 3.5mm jack or HDMI,Networking:- Ethernet (10/100/1000 Mbps), WiFi (optional) ,Resolution Support :- Max: 4096 x 2160 @ 60Hz, Min: 480i @ 60Hz,Frame Rate Support :- Horizontal: 15-91 kHz, Vertical: 24-120 Hz,Pixel Clock :- Max: 594 Mpix/s (supports high resolutions and refresh rates),3D and HFR Support :- 3D Formats: Frame packed, top/bottom, side-by-side (up to 120Hz), Optional Input: Up to 1920 x 1080 @ 120Hz,Control Interfaces :- RS-232, MIDI/OSC, Web Interface,Networking and Remote Control :- Ethernet (10/100/1000 Mbps), WiFi (optional) ,Warping and Blending :- Built-in warping and blending, compatible with external video processors and controllers,Standard Accessories :- Power cable, manuals,Optional Accessories :- External control interfaces, additional storage ,Operating Voltage :- 100-240 VAC @ 50/60Hz ,Power Consumption :- Max: ~250-500W (varies by configuration) Power Management :-Various power-saving modes available, Operating Temperature :- 50-95°F (10-35°C),Operating Humidity :- 10-80% non-condensing, Warranty :-1-3 years parts and labor (varies by manufacturer and region), extended support available :-24/7 support available from manufacturer or authorized dealers 62 Laptop :- Hard Disk Size 512 GB, CPU Model Intel Core i7,Processor: 13th Generation Intel Core i7 1255U Up To 4.7GHz ,Operating System: Pre-loaded Windows 11 | ,Laptop, Power Adapter and User Guide,Display: 38cm 16:10 FHD (1920x1080), 60Hz 45%NTSC IPS-Level,Memory & Storage: 8GBx2 DDR5 Onboard Dual Channel RAM | Storage: 512GB NVMe PCIe Gen3x4 SSD,Intel Iris Xe Graphics | 802.11 ax Wi-Fi 6 + Bluetooth v5.2 63 DeskTop - High-performance desktop workstation comprising AMD Ryzen 9 7900 processor, compatible ATX motherboard with PCIe 5.0 support, 32GB DDR5 RAM (2x16GB, 6000MHz), 1TB NVMe Gen4 SSD (Samsung 980 Pro or equivalent), NVIDIA RTX 4060 Ti 8GB GPU, 750W 80+ Gold certified power supply, mid-tower cabinet with efficient airflow and acoustic insulation, 240mm liquid CPU cooler, 27” QHD IPS monitor with 99% sRGB coverage (Dell UltraSharp or equivalent), professional-grade audio interface (Focusrite Scarlett 2i2 or equivalent), and Windows 11 Pro OS. All components to be compatible for seamless performance in professional audio-video editing, mixing, 3D rendering, and multimedia production workflows. 64 Automation console - watchout :- Multi-display and multi-resolution support , · Timeline-based show creation,· Real-time show control via TCP/IP,· Live video input (NDI®, SDI, HDMI, capture cards),· Audio playback and synchronization,· External control via MIDI, Art-Net, DMX, and other protocols,· Support for image sequences (e.g., PNG, TIFF), videos (H.264, HAP, ProRes, etc.),· Automation and scripting support,· Support for 4K/8K+ playback (hardware dependent),· Geometry correction and soft-edge blending,· Output synchronization across multiple display servers 65 External Hard disks :- Brand - ‎LaCie / Manufacturer - ‎Lacie, Seagate, Series - ‎D2 Professional / Form Factor - ‎3.5-inch / Item model number - ‎STHA8000800 / Hard Drive Size - ‎8 TB / Hard Disk Description - ‎Mechanical Hard Disk / Hard Drive Interface -‎USB 3.0 / Hard Disk Rotational Speed - ‎7200 RPM/ Hardware Platform - ‎PC, Mac / Operating System‎mac os / Included Components - ‎LaCie® d2 Professional; USB-C (USB 3.1 10 Gb/s) cable; External power supply; Quick Installation Guide; Rescue Data Recovery Services4 / Manufacturer - ‎Lacie 66 Weatherproof canopies for projectors and speakers -Supply, fabrication, and installation of custom-designed weatherproof canopies for outdoor projectors and speakers, constructed using powder-coated mild steel, stainless steel, or aluminum with UV-resistant polycarbonate or acrylic panels (for projector visibility), designed to protect equipment from rain, sunlight, dust, and wind. Each canopy shall include a sloped roof for water drainage, IP55 or higher ingress protection rating, proper ventilation to prevent overheating, lockable access panels for maintenance, vibration-dampening mounts (for speaker housings), and suitable mounting provisions (wall, ceiling, or pole). All materials must be anti-corrosive and suitable for long-term outdoor use. Installation shall follow manufacturer guidelines and site conditions. Approved Makes / Equivalent: Tempest, Chief (Legrand), Peerless-AV, SunBriteTV, Vanco, Middle Atlantic, or equivalent.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
37.
Defence #9353987 Technical Bid
Tender For Provision Of Work Services For Solar Power Plant At Af Stn Adampur; 1 SCHEDULE `A PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 Construction of SUB STATION BLDGcomplete all as specified and shown on drawings. 3 NOTE: Schedule ‘A’ Part IIto X under Ser No. 2.01to 2.10 are Prepriced by MES. 4 Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 5 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION as listed in Schedule ‘A’Part III 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 7 Lump sum price worked out by the Contractor for “SOLAR POWER PLANT” as listed in Schedule ‘A’Part V 8 Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’Part VI 9 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’Part VII 10 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’Part VIII 11 Lump sum price worked out by the Contractor for“SEWAGE DISPOSAL ” as listed in Schedule ‘A’PartI IX 12 Lump sum price worked out by the Contractor for“AREA DRAINAGE” as listed in Schedule ‘A’Part X 13 Lump sum price worked out by the Contractor for“FENCING AND GATE” as listed in Schedule ‘A’Part XI 14 SCHEDULE `A PART - XII MISC ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 15 INTERNAL ELECTRIFICATION 16 S&F LED light fitting 1 x 10 Watt, 220V, AC,box type with driver, holder incl making connection with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed. 17 S&F LED security light fitting 20 watt, input 110 to 220 voltsas per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed. 18 SOLAR POWER PLANT 19 Design, supply, erecting, installation, testing & commisssioning of ON Grid connected, ground mounted solar PV Plant of 737 KWp capacity at standard condition (irradience temp etc) at AF Stn Adampur (Longitude 75° 44 20 E, Lattitude 31° 26 14 N & elevation 244.54 mtr). The ripple content shall not exceed 3% on DC and harmonics shall not be more than 3%, Micro processor based directional & revese power flow protection shall be provided to ensure isolation of SPV from Grid at the time of fault including all connected equipments required for their smooth functioning comprising of the following major componenets all as specified:- 20 Supply, erecting, installation, testing & commissioning of framed dual glass bifacial Solar modules each consist of 144 cells (12x6+12x6), size of module 2278mm (L) x 1134mm (W) x 33mm (T) or as approved, M10 TOPCon N type mono bifacial solar cells not less than 585 Wpeach, front glass 2mm low iron printed semi tempered glass, back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate, IP68 weatherproof PPO junction box, compatible with IP68 rated MC4 connector alogwith 1400mm DC, Copper cable of 4sqmm size, anodized aluminium framehaving efficieny more than 22.5% at standard test condition. These panels shall be suitably fixed on Module mounting structure. The electrical Data of panel at standard test condition (STC) 1000W/m² irradiance, air mass 1.5 & 25°C cell temperature shall be as under:-(i) DC peak power (Pmax) - not less than 585 Wp. (ii) DC peak voltage (Vmp) - 44.15V (Approximate). (iii) DC peak current (Imp) - 13.25A (Approximate), (iv) Short circuit Current - 13.99A (Approximate). (v) Open circuit Voltage - 52.70V (Approximate). (vi) Module efficiency - 22.65% (Approximate). (vii) Operating temp range (-) 40°C to 85°C. (viii) Series fuse rating = 30A (Approximate). (ix) Junction box = IP68, weatherproof PPO. (x) IP68 rated MC4 connector compatiable. (xi) Anodised aluminium frame. (xii) front glass 2mm low iron printed semi tempered glass. (xiii) back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate. (xiv) Sustain heavy snow upto 5400 Pa. (xv) Sustain wind loads upto 2400 Pa. 21 Note :-(a) The PV modules must be tested and approved by one of the IEC authorised test centers. In addn a PV module qualifacation test certificate as per IEC standard, issued by ETDC Bangalore or Solar Energy Centre will also be valid. (b) Warranty on output and life of structure shall be as under :-(i) Output wattage of PV modules shall not be less than 90% at the end of 10 years and 80% at the end of 25 years.(ii) The mechanical structure, electrical works and overall workmanship of the grid solar power plant must be warranted for a minimum of 5 years.(iii) Grid solar PV power plant must install necessary equipment to measure solar radiation, ambient temperature, solar energy meter 11 KV to measure grid solar power generation, wind speed and other weather parameters contnuously. Simullataneuosly measurement of the generation of DC power as well as AC power from the plant must be done. 22 (c) Each module shall have RFID tag bearing the following details. RFID reader shall be provided by contractor :-(i) Name of manufacturer of PV module (Should be made in INDIA). (ii) Name of manufacturer of solar cell (Should be made in INDIA). (iii) Month and year of manufacture (Separately for cell & module). (iv) Country of origin separetly for cell & module (Made in INDIA only). (v) Peak Wattage, Im, Vm and fill factor of the module. (vi) Date of year of obtaining IEC PV module, qualification, certificate. (vii) Unique serial no and model no. of Module. (viii) I-V curve of module. (ix) Name of the test Lab issuing IEC certificate. (x) Every module should have PID test report as per latest prevalling norms of MNRE & will be submitted to the GE. (xi) Solar cells & Modules shall meet DCR norms. 23 (d) Provision of earthing and earth strip/cables etc. for earth for solar PV module/Array as per latest IS/MNRE norms to be providied it will be measured and paid seperatly. (e) PV module shall confirm to IEC:61215, IEC: 61730, UL:61730-1 & 2 for construction, testing and safety qualifacation and latest minimum technical specifications. The module shall be manufactured in 2024 or subsquent year. Product warranty shall be for at least 12 years and performance warranty shall be at least 25 years. 24 (f) The contractor will submit the complete design of ON Grid connected Solar PV Plant alongwith complete design details, drawings, calculation sheet and connected documents within one month of acceptance of tender and before procurement of the material. The same shall be submitted to GE after vetting from IITs/NISE for approval of accepting officer. (i) The complete design will submitted to Accepting Officer through CWE for final approval before placing order of the materials to be used in Solar PV Plant. (ii) The test report of modules as per national and international standards and technical data shall be submitted by contractor to GE for approval of accepting officer. (iii) Minimum 0.5% of PV Module shall be tested for all electrical parameters incl efficieny & safety measure by the rep of AO at OEM factory premises before dispatch as per technical data sheet of the manufacturer. (iv) Contractor will submit 2% amount of total quoted amount against item Sl No 4.04 (PV Module) as performance security of PV Module in the form of FDR or BGR in favour of the Accepting Officer which will be refurned to the contractor on successful performance copletion of 25 years of PV Module.(v) Contractor will submit gurantee for at least 25 years performance of PV Module as per CA provision and in case of any manufacturing fault of any PV Module during the performance warranty of 25 years the same shall be replaced by the contractor without any extra cost. (vi) All the modules shall be of same make. (vii) Rates of testing at Factory premises of OEM or MNRE approved Lab are deemed to be included in the quoted rates.(g) Make : MNRE approved and as per list of makes mentioned in Appx D of the tender documents. 25 (viii) The solar power plant shall be got tested/ inspected by third party i.e. NISE or any other Govt approved lab as decided by Accepting officer. Cost of testing and all other arrangement for this shall be made by the contractor without any extra cost.Third party inspection/ testing shall be carried out after execution of complete work and all departmental testing. (ix) Acceptance/ Final test from rep of Accepting Officer shall be carried out after physical completion of solar power plant work.All arragement for this shall be made by the contractor without any extra cost. (x) The following tests shall be carried out: (i) Performance ratio test (ii) CUF (iii) Efficiency test (iv) Irradiance test (xi) All drawings and design duly supported with detail calculation and property of the equipment shall be submitted by the contractor within two months from the date of issue of work order for approval of the Accepting officer. 26 Design, supply, installation, testing & commissioning String PV Inverter of capacity not less than 250 KW. Input DC & output AC specification of the inverter shall be as under :-Input DC. Max input DC voltage not less than-1500V, rated input voltage not less than 1080V, start up voltage 550V, minimum MPPT voltage range 180-1500V DC, MPPT voltage range at full load 800-1300V DC, minimum number of string input 24, minimum number of MPP trackers-12, string per MPPT- 2 Nos, max input current per MPPT shall not be less than 30A, max short circuit current per MPPT shall not be less than 50A. 27 Output AC.Minimum AC output power 250 KVA@30°C, 235KVA @40°C, 220 KVA @ 50°C, max output current not less than 184A, Nominal 3 phase voltage- 800V, minimum Grid voltage range 640-920V, Frequency- 50/60Hz, Grid frequency range - 45~55Hz, Active power adjustment range- 0-100%, THDi- <3%, power factor 0.8 leading-0.8 lagging, 3 phase.Performance.Max efficiency - not less than 99.01%, European weighted efficiency - not less than 98.8%, outdoor string solar power grid tie inverter suitable to convert DC power of solar PV module/array to AC for further feeding to grid & conforming to IEC-61683 for efficiency, IEC-62109 (1&2) or equivalent for safety & IEC-62093 for reliabilty. The inverter shall be self-communicated with pulse width modulation (PWM) technology and shall be capable to synchronize with grid maximum in 1 minute. Maximum Power point tracker (MPPT) conforming to IEC-62093 shall be intergrated in the inverter to maximize energy drawn from the solar PV array. 28 The inverter shall have following protections:- (i) DC reverse polarity protection. (ii) Anti Islanding protection. (iii) Leakage current protection. (iv) Ground fault monitoring. (v) PV array string fault monitoring. (vi) Zero voltage ride through. (vii) DC switch. (viii) Anti PID protection. (ix) AFCI protection (Arc Fault Circuit Interrupter). (x) Over voltage. (xi) Under voltage. (xii) Overload. (xiii) Shorcircuit. (xiv) Earth fault. (xv) Under frequency and over frequency.Protection class/Overvoltage category- I/III. Input/output SPD- PV type-II & AC type-II standard. Electromagnetic compatibility (EMC) as per EN-61000-6-2&4. Safety standard as per IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068(1,214,30). Communication- RS485, USB, Bluetooth, Wi-fi, GPRS, PLC.Inverter shall monitor the following:-(i) DC input voltage (ii) DC input current (iii) DC ripple (iv) DC input power (v) AC output (vi) AC output current (vii) AC output power (viii) AC output frequency (ix) AC output power factor (x) Synchronization status (xi) Grid voltage (xii) Grid frequency (xiii) Grid (ii) Ground fault (iii) PV string fault montioning inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. 29 General specification:- (i) Ambient temperature range - (-) 30°C to (+) 60°C. (ii) Self consumtion power at night - < 2W, Topology- Transformerless. (iii) Degree of protection - IP66. (iv) Allowable relative humidity 0-100%, max operating altitude - not less than 4000M, (v) Noise - <60Db. (vi)Cooling - Smart forced air cooling. (vii) Display - LCD & Bluetooth+App.Rate for PCC foundation including required concreting and steel fixing as instruction and directed by engineer-in-charge are deemed to be included in quoted rates.Isolation method tranformer less smart forced cooling LED display, Rs 485/PLC communication, smart IV Curve Diagnosis, Type II SPD for both DC & AC with 5 years guarantee. Make: HITACHI/Delta/Sungrow.Note:- (i) Contractor shall submit parameter sheet of inverter duly recommended by GE & CWE for approval of AO before placing order to the company. (ii) All the inverter shall be of the same make & model. 30 MC4 CONNECTORSSupply, installation, testing & commissioning of solar MC4 connectors (Male and female both) having copper pin with tin plating with 1500 V DC & not less than 30 Amp. Current suitable for 4/6 sqmm cable, degree of protection IP-68, contact resistance < 2 mili ohm, insulation resistance >500 Mega ohm, insulation material PPO, protection class-II, application class A, standard EN 50521: 2008 TUV certified and shall also meet the requirement of IEC:61984 complete all as specified and directed. Make: Indygreen/Elmax/synergy/Eteilyte Technologies India Pvt Ltd . 31 Modules Mounting Structure (MMS) Design, supply and erect Module mounting structure made up of MS Hot dip Galvanised (80 Micron) as per IS 4759, GI frame Structure to hold approved solar panels mounting with all accessories.Fixing arrangements for fixing the PV solar modules & to withstand minimum horizontal wind speed of 170 km/ hr as per IS. It shall conforming to latest revesion of IS 2062 having Grade of 250 MPA. The MMS design shall be submitted by the contractor and shall be approved by AO. The solar panel shall be fixed at a tilt angle of 31° or as per designed SPV Plant. Note : The design should be similar as per drawing attached. 32 Mounting Structure shall have following specification:-(i) Nut, bolts and supporting structure including module mouting structure shall have to be adequately protected from atmosphere and weather prevalling in the Adampur Air Force Station. All fastners shall be of stainless steel of Grade SS 304.(ii) Two numbers of anti-theft fastners of stainless steel on two diagonally opposite comer of each module shall be provided.(iii) The rep of AO, shall visit the factory site of galvanising for each section of lot of dispatch to collect the samples at random & send the sample duly sealed & signed by him and rep of contractor to nearest NABL accredited Lab for testing. The lot will bedispatched from factory permises only after passing of sample from Lab. In case of failure of sample complete lot will be rejected. The quoted rates are deemed to include these provisions. 33 Note:- (i) cost of interconnecting copper cables along with cable trays (floors/ wall mounted) suitable to accommodate solar grade cables & cables upto invertersshall be measured and paid separately under relevant items. (ii) Earth work and foundation of MMS shall be measured and paid separately under relavent items (iii) MM structure shall be paid as per actual size installed st site. 34 M&L for tinned copper conductor, 6 Sqmm XLPO insulated and sheathed, UV-stabilized, single core multi-stranded DC cables- RED & BLACK (FOR PANEL INTER CONNECTION), complete as all specified below and directed.(1) Construction(i) tinned copper conductor IEC 60228, class-S(ii) Insulation/sheath:- electon beam cross linked halogen free & flame retardant compound (XLPO)(2) Electrical(i) Voltage Test: 6500V as per EN 50395 (ii) Max permissible operating Volatge:- DC 1.5 KV (conductor-conductor, non earthed system)(iii) Nominal Voltage :- AC 0.6/1.1 KV & DC -900/1.5 KV(3) Temperature(i) Amblent temp: (-) 40°C to (+) 90°C (ii) Max conductor temp (-) 40°C to (+) 120°C(4) Strandards & Material properties(i) Fire performance -IEC 60332-1-2(ii) Smoke emission:- IEC 610374/EN 50268-2(iii) Approval :- EN 50618, HIZ272-KMake: Polycab/Havells/Finolex/KEI India/RR KabelNote: (i) Routine testing of cable shall be carried out by rep of AO at the factory premises of OEM, before dispatch. 35 Supply and laying in trenches, 3.3 KV underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 3300 Volts grade, cross sectional area 300 Sqmm, 3.0 core multistranded, confirming to IS-7098 (Part-1):1988 suitable for earthed system including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge. (ACDB to LT Panel and LT Panel totransformer). 36 All same as per item No 4.17 above but size of 120 Sqmm 3.0 core (Busbar No 1 to ACDB No 1, Busbar No 2 to ACDB No 2 and Busbar No 3 to ACDB No 3) 37 M&L for 70 Sqmm 3.0 core, 1100 volts grade PVC Copper Cable flexible, conforming to IS 7098 (Part-2):1988 (Inverter No 1 to Busbar No 1, Inverter No 2 to Busbar No 2 and Inverter No 3 to Busbar No 3) complete all as specified and directed by Engr-in-Charge. 38 HT TRANSFORMER (INVERTER DUTY FOR SPV PLANT)Supply, installation, testing & commissioning of copper wound, step up cum inverter duty conforming to IS:2026 or latest IS standard, HT Transformer, outdoor type capacity not less than 1000 KVA, 0.800/11KV, 50 Hz, Dyn 11, ONAN class A for solar application, Star Delta Tapping + 7.5 % to -7.5% @ the step of 2.5% ON load type tap changer, with first filling of transformer oil as per IS:355, ISI marked , duly filtered & Dehydrated and other standard fitting/ accessories including Platform & foundation for Transformer installation as recommended by manufacturer. The total losses (No load + Full load) at 75 deg C shall not be more than 1% of rated capacity of transformer, Impendence 5%. The following are included:-(i) Name, rating & diagram plate. (ii) Tap changing switch. (iii) Earthng terminals. (iv) Lifting lugs. (v) Oil level indicator 150 mm dia with alarm & trip contact. (vi) Oil drain valve with plug (vii) Oil filter valve with plug. (viii) Conservator with oil filling hole with cap. 39 (ix) Thermometer pocket. (x) 4 Dial type thermometer stem type & with MRP. (xi) Air release plug. (xii) Silicagel breather. (xiii) Removable inspection opening on top cover. (xiv) Explosion vent. (xv) Bi-directional CI rollers. (xvi) Arching horn set. (xvii) Winding temperature indicator with alarm & trip contact. (iii) Marshalling box for 03 Nos. (iv) Magnetic oil level gaugue (v) Pressure release valve (PRV) with trip contact. (xviii) Conservator with oil filling hole with cap & drain plug and with bulit in diaphragm to avoid direct air contact with transformer oil. (xix) Oil level indicator with minimum level marking. (xx) HV cable box (xiv) LV cable box (xv) Bucholz relay with control connection upto HT VCB including testing at OEM premises.Note : Cost of PCC foundation as per OEM foundation drawing & necessary earth work (excavation, returning filling & making good to surface) shall be deemed to be included in quoted rate.Make:- GEC (Prolec)/ABB/Siemens/Schneider/ITE Gurgaon/CG Power & solution Ltd. 40 M&L for 50 Sqmm single core, 0.6/1.1 KV PVC insulated and PVC sheathed Copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 41 M&L for 6 sq.mm single core, PVC insulated and PVC sheathed copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 42 M&L for 1 sq.mm , 2 core, RS 485 cable twisted shielded unarmoured copper cable complete as all specified and directed (Data Monitoring Cable for communication) 43 ACDB Panel for 750 KWp Inverters (3x250 KW inverters) Design, supply, installation, testing & commissioning of outdoor type, floor mounted ACDB Panel for 750 KW Inverters having 3 incoming & 1 outgoing, IP-65 protection rating with PCC foundation for civil works (Excavation, cutting, Grouting, PCC etc) Fabrication with 3.15 mm thick CRCA sheet steel, 7 tank power coated, floor mounted panel with 40x40x6mmMS angle stand, cable entry from bottom through gland plates, internal control wiring with suitable size copper cables, cable alley, three numbers 1200 Amps aluminium bus bar EC grade incld heat shrinkable PVC sleeves complete all as specified and directed and having following switchgears :- 44 OUTGOING:-1 No.800 Amp, 3 Pole,50Hz, 3 phase, ACB Drawout type, motorised charging, with microprocessor release, Icu = Ics = Icw 50 KA,suitable for 800 volt, 3 phase, 50 Hz with ACB spreader Link with R,Y,B LED indicating light, digital Multimeter 800 volts CL-1, 3 Nos Metering CT 800/5A TP SPD Type 1+2 40 KA. INCOMING :-3 x 250 Amp, Icu = Ics = 36 KA 3 pole MCCB microprocessr released with spreader links. The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01(b) Ammeter with selecter switch -01(c) Frequency meter - 01(d) R,Y, BIndication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three.(f) CT 800A/5A, CL-0.2, 5VA- Set of three(g) Auxiliary transformer 50 VA, 800V/230V - 01 NoNote:- Contractor shall submit drg of ACDB panel to GE for approval of accepting officer before procurement. 45 LT Panel for 750 KWp inverters Design, supply, installation, testing & commisssioning of outdoor type, floor mounted LT panel of 3.15mm thcik CRCA sheet steel powder coated for 750 KWp inverters having 1-input & 1- output, IP-65 rating, cable alley with PCC foundation for civil works (excavation, cutting, grouting, PCC etc) TP SPD,type 1+2 40 KA, MCCB extended ROHM, all cable entry from bottom through gland plates, 3 Nos control fuse 16A with base for SPD,three 1200 Amps Aluminium bus bars Ec grade incl heat, shrinkable PVC sleeves, Aluminium busbar links, internal wiring with suitable size copper cables, with 40x40x6mm MS angle stand , 7 tank powder coated, three 6A SP 10KA MCB C Curve etc complete all as shown on drawingscomplete all as specified and directed. 46 INCOMING:-1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links.OUTGOING1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links:- The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01 No(b) Ammeter with selecter switch -01 No(c) Frequency meter - 01 No(d) R,Y, B Indication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three (f) CT 800/5A, CL -0.2 , 5VA - Set of three(g) Auxiliary transformer 50 VA, 800V/230V -01 No.Note:- Contractor shall submit drg of Panel to GE for approval of accepting officer before procurement. 47 COPPER BUSBAR CHAMBERM&L for outdoor type, floor mounted , vermin proof, totally enclosed bus bar chamber of not less than size 800 mm (H) x 800mm (W) x 600 (D) made out of 3.15 mm thick CRCA sheet , incl three number 300 Amps pure copper busbar having size of 200 MM (w) x 100 MM (thick), 0.5 Mtr length/ phase incld heat shrinkable PVC sleeves, duly supported on insulators, it shall be IP-65 rated. Cable entry from bottom and suitable for input of 70 sqmm, 1.1 KV copper cable and output of 120 sqmm, 1.1 KV XLPE cable, powder coated complete all cable entry from bottom through gland plates all as spceified and directed. 48 MONITORING SYSTEMDesign, Supply, installation, testing & commissioning of monitoring system to monitor the performance of the PV Module & inverter (Power arrray voltage, array current & AC parameters), energy yield temperature, irradiance level, humidity, Air Mass, wind velocity etc, and it could provide flexible interface to facilities PC based inverter monitioing and control via GPRS modem and internet/ethenet connection. This should have include web visulization system and data logger with integrated ethernet port. The monitoring system shall be comprises of following :-(a) 5G based plug and play RTU with smart data logger to connect inverters & sensors - 1 Set. (i) Modbus RS485 RTU. (ii) 2 Analog ports. (iii) Built in memory help store and send data in case of network failure. 49 (b) IP-67 Enclosure box (280mmx190mmx130mm) or as approved with SMPS power supply and other accessories to house the RTU - 01 No.(c) Access to web portal-server charges for 1 years data frequency 10 minutes.(i) Interractive Dashboard. (ii) Single line diagram. (iii) PR analysis. (iv) Solar radiation & weather data. (v) Graphics and reports. (vi) Generation analysis. (vii) Log reporting. (viii) String/MPPT monitoring. (ix) Plant/Inverter performance. (x) Superuser dashboard for centralized monitoring. (xi) Mobile app on android. (d) Weather sensors.(i) Solar radiation sensor with mounting kit - 01 No. (ii) Wind speed sensor with mounting kit - 01 No. (iii) Ambient temperature sensor with mounting kit - 01 No. (iv) Module temperature sensor with mounting kit - 01 No to be provided complete with readouts integrated with the data logging system. 50 (v) Analog to modbus module - 01 No. (vi) Wind direction sensor with mounting kit - 01 No.(e)All in one Desktop computer, 12 th Gen intel core i3, 21.5 inch monitor screen, FHD display, 8 GB RAM, 512 GB SSD with Window 11 including wireless keyboard and mouse complete. Make : HP / Dell/ Lenovo / Microsoft(f)Laser Jet Printer, print speed not less than 18 ppm, power consumption not more than 320 watt, capable to print on A4, A5, B5 & legal size paper, single function including power cable & USBcable, toner, installation CD and user manual complete. Make : HP / Canon/ Xerox 51 Note : The following information shall be displayed in the monitoring system:-(i) Individual module power generation, voltage, current, irradiance and temperature etc.(ii) Individual string power generation, voltage, current, irradiance and temperature etc.(iii) Total power generated of all strings, voltage, current, irradiance and temperature feeding to each invertor. (iv) input voltage, input current, output voltage, output current and power losses of each inverter.(v) Total power, voltage, current, temperature at input of solar transformer, also output parameters such as output voltage and output current of solar transformer. 52 EARLY STREAMER EMISSION (ESE)Supply, installation, testing & commissioning of 5m high, advance active on generating Early Streaner Emission (ESE) lightning arrestors with lightning counter to provide radius of protector of minimum 107 m at level-IV. The lightning arrestors shall conform to IEC 60099-4 or IS 3070 except to the extent modified in the specification. Arrestor shall be hemetically sealed units, self -supporting construction, suitable for mounting on lattice type support structurs complete as specified and directed by the EIC & shown in drawings. 53 Lightning Protection system on protective Early Streamer Emission (ESE) technology confirming by NFC 17-102-2011 and UNE 21186 Standard, Non electronics based deivce shall emit electronmagnetic impulse in the form of a streamer intothe air microseconds earilier than naturally.(i) Lightning impulse current (10/350 µs) in 100 KA tested (ii) Serial no mentioned in Each Model of Air Terminal quality certificate. (iii) Material metal housing stainless steel 304. (iv) central rod dia 20 mm elect/magnetic shielding (v) can be qualified in compliance of CPRI (central power research institute). Govt of India for the Impluse current of (8/20 µs) in 40 KA with 5 poistive & 5 negative impluse (vi) Covering radius 107 meter in Level-IV Protection with 8 mtr mast. 54 Lightning Air Terminal Adaptor. Supply of highly insulated polyplatic adaptor to fix the lighnting ESE air terminal with the mat. The adaptor shall have suitable metal connector/ connecting point in such a way the top portion shall be electrically connected to the central final trip (elevated sharp tip) of the ESE air terminal and the bottom portion shall be connected to the down conductor. 55 MAST GI (supporting mast): supply of GI mast for mounting the terminal & adaptor with the ESE air terminal i compliance with IEC 62561-1.(i) GI mast length:- 8 Mtr (ii) GI pipe heavy duty, bottom 80mm dia, 3m, middle pipe dia 65mm, 2m (iii) standard: IS 1239 Part I): 2004 (iv) Base plate: GI Base plate size (250x250x5mm) (v) both the GI mast to be connected with the help of 2 flanges with 4 GI plated nut bolt with washers. The base plate size in (300x300x6mm) GI with requisite fitted with 4 hold the mast. (v) Necessary concrete foundation, earth work for holding the lightning conductor in position is deemed to be included in quoted unit rate. 56 Guy Wire Kit: Supply of Guy wire GI Nickel coated 4mm dia. Covered with white sleeve for extra protection and avoiding rusting. Length of the Guy wire is 6 mtr x 3 no = 18 mtr with accessories like:(i) Guy wire Nickel coated with white convered waterproof sleeve-18 metre(ii) U clips - 6 nos (iii) Pin type zebra anchor fastner-4 nos (iv) O hook- type fastner/ eye bolt fastener-3 nos (v) GI nut bolt 12mm dia of suitable lenth - Nos as per site requirement. 57 Lightning Strike Counter: minimum sensitivity of 250 A at 100 KA.(i) Display Model: digital display (non- resettable type) (ii) Display Range: 000000 to 999999 (iii) Detected Maximum discharge current : 350 A, 10/350 microsecond wave (measurd according to NFC standards per IEC 60060-2)(iv) Tested as per IEC-60060-2 (v) Degree of protection : IP 65 (vii) Operating Temperature (*C): 20+~85 (viii) Strike count display 6 digt (ix) Standard NFC17 102 (2011) Make- Saboo Sysyems Pvt Ltd/KMV/ABB/Axis India Note: Item No 4.34 to 4.39 (i) Lightning arrrestor & its components shall preferably be supplied by same manufacturer. The installation shall be carried out by rep of manufacturer. Testing of LA shall be done in presence of Engineer- in- charge. 58 Chemical Gel Earthing system: Supply for advance chemical Gel earthing system of 1 No. of UL certified 7 CPRI tested environment friendly ground enhancing compund. The copper bonded rod shall be 3 mtr long, 17.2mm diameter 254 microns copper bonded steel rod surrounded with 25 Kg each or more quantity of resistance lowering grounding minerals ROHS certified. Distance between the rod shall be length of the rod all as shown on drawings.(i) Tested as per IEC 62561-2 (ii) CPRI tested at 5 positive & 5 Negative impluse 25 KA (iii) Meets the requirments as per IS 3043, IEC 60964-5-54, UL 467 (iv) Standard- As per IS-3043 & IEEE80-2000, Test certificate from NABL lab. Make : Pragati Electrocorp (P) Ltd Gurgaon / DEHN / JEF Techno 59 Pit Chamber-Round value box supply of FRP heavy duty UV resistance, weather proof earth pit cover as per OEM recommendations complete all as specified and diected. 60 M&L for UPVC pipes of 40 mm size for DC wires, having pressure capacity of 10 kg including fiting viz joints bends, tees, etc complete all as specified and directed. 61 M&L for UPVC pipes of 25mm size for DC wires, having pressure capacity of 10 kg including fiiting viz, joints, bends, tees etc complete all as specified and directed . Note:-(i) Earth work shall be measured and paid under relevant item. 62 M&L for perforated hot dipped galvanized iron cable tray having cable tray for AC & DC cable routine (300 x 50 x 5mm and 450 x 50 x 5mm) thickness 1.5 mm galvanization and perforation not more than 17.5% includeding fittings viz joints, bends, tees, etc in convenient section of length complete all as specified and directed. 63 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specifications:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip rod and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging handle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II class-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. 64 (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Separate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type (25 KA for 1 second) as per latest IEC:62271-200. (g) Vacuum bottles should be tested for 100 full short circuit operations. (h) Manual closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack battery backup for not less than 10 minutes. 65 (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contactor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 66 Supply, installation, testing and commissioning of three phase, 4 wire Bi-Directional HT CT/PT Digital Energy Meter automatic grade as per relevent IS, 110-240 V, (66 KV/Ѵ3/110/Ѵ3) industrial application, Optical Port, RS 232/485 communication current rating Imax 2A -/1A, automation grade, accuracy class 0.2s, D3M024 type and suitable to install between 66 KV Sub Station (Commercial supply of PSPCL) in replacement of existing PSPCL energy meter and 750 KWp Solar power plant, display parameters like KWh, KVArh, KVAh, KW, kVA, Frequency, Power Factor, Current, import and export of energey complete all as specified and directed by Engr-in-Charge. Make : Secure, model : Premier 300 or its technno commercial equivalent.Note : The contractor shall liaise with PSPCL for testing & calibration of the meter. Cost of the same deemed to be incuded in quoted rates. 67 ROAD/PATH/CULVERT 68 M&L for providing and marking broken centre/ side lines/zebra Lines, dashes, arrows etc on road pavement and the like of any description and width with thermoplastic paint hot applied with machine confirming to BS-3265 and according to the specification laid down by IRC and MOST (Mininstry of Surface Transpost) specification 2001 (4th revision) complete all as specified and directed. 69 EXTERNAL WATER SUPPLY 70 Construction of brick masonary valve pit of size 1000x1000x1000mm (internal dimension) with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using pulverised fuel ash lime bricks in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engr-in-Charge. 71 PVC HDPE rotational moulded 5000ltr capacity water storage tanks (Cylindrical vertical type with closed top) triple layered,fixed in position and making inlet and outlet water piping line connections complete all as specified. Note : Staging for PVC water tank shall be paid separately under respective item. 72 S&F Pumping sets, centrifugal monoblock, electric driven, single phase, 2HPhaving discharge capacity 3.2 LPS at 20 mtr head, suction x delivery size 50x40mm all as specified and directed by EIC. 73 Supply and fixing PVC air braided hose pipe 25mm dia. 74 M&L for provisioning of staging at 2 mtr height for PVC HDPE storage tank 5000ltr capacity. Note : S&F of PVC water tank of 5000 ltr capacity not included in this rate and shall be paid saparetly under respective item. 75 SEWAGE DISPOSAL WORKS 76 Supply and fixing ofLLDPE septic tank designed to carry sewage and sullage, water including excavation in anytype of soil, PCC 1:4:8, PVC Pipe from last manhole to septic tank, vent shaft, vent cowl and misc connection like PVC Tee, PVC bend etc. complete for PWTS-STBF-160-01 (1600 Lts Capacity) (Make - Sintex) 77 Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0M deep. (CEJZ/STD-301/90 SHEET No 1/4to 4/4) 78 EXTERNAL ELECTRIC SUPPLY 79 Supply, installation, testing and commissioning of 11 KV, 630 Amp, 50 Hz, SF6 gas insulated, 21 KA/3 Sec 3 way Ring Main Unit of outdoor type, motor operated, extensible with 01 No. VCB 630 Amps as incommer and 02 Nos LBS as outgoing cable termination from front (Internal arc classification AFLR 21KA/1 Sec with bottom exhaust both for tank and cable box as per IEC:62271-200), enclosed in welded stainless tank having IP-67 degree of protection, leak rate of SF-6 gass less than 0.1% and tested as per IEC:62271-200, ring core type protection CT, line side isolator alongwith following technical specification:-(a) Electrical specification. (i) Nominal system voltage - 11 KV. (ii) Voltage variation on supply side - + 10 (iii) Corresponding higher system voltage - 12 KV. (iv) Transient condition - (-)20% or 10% combined variation of voltage and frequency. (v) Lightening impulse withstand voltage upto 75kVp. (vi) one minute dry/wet power frequency withstand voltage primiary - 28 KV. 80 (vii) Rated dynamic withstand current - 52.5 KA. (viii) No of short circuit operations at rated short circuit current of 21 KA for breaker - 50 Nos.(b) General specifications. All live parts, bus bars, shall be preferably be enclosed in non megnetic and non ferrite grade stainless steel tank grade SS-304 of minimum 2.5 thickness. The RMU shall be tested for internal arc test of 21 KA/1 Sec AFLR with bottom exhaust for safety of personnel for both tank as well as cable compartment as per IEC:62271-200. The outdoor enclosure shall have IP-55 protection for complete switchgears with top opening canopy & dedicated IP-55 cable compartment. The protection relay shall be for 3 o/c + 1 E/F (IDMT Type) self powered numerical protection relay with low and high set of over current and earth fault, MODBUS communicating alongwith RS-485 Port. Internal Arc classification should be with bottom exhaust only. The RMU should be SCADA compatible and trouble free operation at the temperature 40 degree C & above. 81 (C) Insulated Bus connected unit comprising of the following :(i)Air insulated enclosure with necessary bus connection via bushing VTs from manufacturer and according to IS:3156. (ii) Sinle phase bus PT for metering - 11 KV/rt3/110V/rt3, 50 VA, class 0.5. (iii)Auxillary transformer - 11 KV/230V AC, 1 KVA. (iv) Multifunction Meter - EM6400 NG class 0.5 for incomer(d) The following accessories should be included in deemed rate:(i) Antireflex operating hadle. (ii) Battery 24 V DC, 12 Ah. (iii) Battery charger 24V DC. (iv) Manometer with remote contact.Note : RMU should be manuctured, inspected by rep of the Acceptung Officer and invoiced from the OEM factory. 82 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specification:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip road and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging hangle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. 83 (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II clause-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Seprate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. 84 (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type typed (25 KA for 1 second) as per latest IEC:62271-200. (g) Vocuum bottles should be tested for 100 full short circuit operations. (h) Mannal closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack batter backup for not less than 10 minutes. (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contractor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 85 (E) Indicating lamps LED type(i) Breaker ON Red clolour - 01 No(ii) Breaker OFF Green Colour - 01 No(iii) Auto Trip indication amber colour- 01 No(iv) Trip circuit heathly clear - 01 No(v) Spring charged blue colour - 01 No(vi) RYB indication - 03 Nos(F) Accessories (i) Trip Neutral Close Switch - 01 No(ii) Space heater with thermostat - 01 No(iii) Local Remote Switch - 01 No(iv) 3 Pin Plug Connector - 01 No(v) MCB AC & DC - 02 Nos(G) Relays(i) Numerical relay 50/51/50N/51N, non communicable, non draw out type - 01 No(ii) Master trip relay - 01 No(iii) Auxillary relay for transformer (3 elecments) - 02 Nos 86 M & Lfor Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. 87 Supply, fixing, testing and commissioning of junction box incl AI bus bar with MCB SP 6A, 10 KA, C curve & PVC cable 2.5 sqmm 2 core weather proof, aluminium conductor upto 7.5 mtr length for connection for single or 3 incoming cable & for outgoing and single phase connection of secuirty light fitting from junction box , PVC conduit pipe upto junction box , enclosed in tehermo plastic enclouser,shock proof , weather , dust , rust & water proof internally embedded gasket with provision for cable entry of size 300x200x125mm alongwith MS clamps, through and incl suitable gland all as specified. 88 Supply, install , testing and commissioning of LT feeder pillar distribution panel board CPRI approved, outdoor type, weather/vermin proof, mae out of 3.15 mmm thick CRCA sheet duly powder coated of suitable size and medium channel 75mm base mounting frame double door factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type 3 phase and netural 200 Amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting busbar connection/linkage complete and conforming to IS : 8623 and IP 54 class of protection as per IS ; 2147 complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below completed and mounting the panel board on ground with PCC (1:3:6) , bedding upto a height 30cm above ground level complete all as specified and directed (OR CH/DH) 89 (a) Aluminium busbar 200 Amp for 3 phase & netural -1 Set. (b) MCCB 4 pole 100 Amps 25 KA at 415 V -1 No (incomig)(c) MCB TPN 32 amps, 10 KA , C curve -Nos (outgoing)-02 , spare-01). (d) MCB SP 16 A , 10KA , C Curve-2 Nos (for street lights). (e) Digital Voltmeter with selector switch 0 to 500 volt- 1 No. (f) Digital Ammeter with selector switch and CTs 0 to 500 Amps-01 No. (g) Timer switch with set of contactors - 1 No. (h) LED type indicator lamps (R 90 MANNING & OPERATION (M&O) UNDER PH-II 91 First year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following:-(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 92 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system.(b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs) 93 MANNING & OPERATION (M&O) UNDER PH-III 94 Second year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 95 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system. (b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
38.
Defence #9324440 Technical Bid
Provision Of Borewell And Connected Items For Augmentation Of Water Supply At Water Point No.6 Under Ge North Akhnoor - Supply and installation of voltage stabilizer for auto matic operation, three phase naturally Oil cooled indoor type and designed input variation between 300 Volts to 480 volts with out put voltage stabilized at 415 Volts with accuraccy +2.5 % and speed of correction 8 Volts per Second and of capacity 100 KVA, including first fill of transformer Oil having dielectric strength of 60 Kv with 3 mm gap, construction of suitable PCC foundation including making of connections and testing complete all as specified and as directed by Engineer in charge. 2 Supply, laying & testing of HT Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 11000 volts, grade cross setional area 95 sq mm, 3 core all as directed 3 Supply, laying & testing of LT Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 95 sq mm, 3.5 core all as directed. 4 Material and labour forAir break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV and for current rating 200 Amp all as specified and directed. 5 Supply and fixing in position Lightning Arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp all as specified and directed. 6 Earthing complete with galvanised steel earth plate elcrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m belwo bnormal ground level connecting to the GI erthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 40mm grade crushed stone aggregrate iwh 40mm thick cover of RCC (1:2:4) raniforced with PM (weight not less than 4Kg/sqmm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light ggrade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth platem common salt and charcoal filling, test point made out of 75x50x6mm phodphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hand/ dense soil rning filling in andremoval of surplus soil to a distance not exceeding 50m all as per electrical plate nmp 5 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion all as specified and directed.. 7 Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materialand accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm all as specified and directed. 8 M&L for LED flood light of capacity 250 watt IP 66 Lumainire with aluminium die cast housing toughened glass and unique lens system for enhancement illuminationcomplete with all accessories Make Wiprocat part No LF3 -342-060-57XXor equivalent in specification of make phillips, Oshram,wipro, GE 9 Supply ,installation ,testing and commissioning indoor type microprocessor based power factor correction system APFC panel MD-XL(mixed dieelectric cpacitor of 30 KVAR and incoming MCCB with suitable steps having auto switching system for each stage in the form of electromagnetic switching system for energising each capacitor stage should have the current carrying capacity not less than 1.5 times the charging current of the respective stage shall carry a back up protection inthe form of tripple pole MCB of rating not less than 2 times charging current. The outer shell of APFC shall be made up of 2mm thick CRCA sheet steel and MS angle section 50x50x6mm frame factory fabricated with front and back openable single door system lockable openable by keys from both sides having 19mm dia fancy locks detachable plate having provision for entry of armoured cable of adequate size with glands.The outer shell be powder coated with siemen grey shade all as specified and directed 10 Material and labourLT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x6mm imbedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made, fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with aluminum busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed,The panel should be IS/IEC 61439-I&II- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. (Note: Panel shall be a front/rear opening with cable entry from the bottom).Make of Panel:Make: Legrand/L&T/Siemen.(a)MCCB 160 Amps,thermal adjustable and magentic setting havingrupturing capacity 36 KA (Ics= 100% Icu) , TP, 415 volts, 50 Hz,along with Extended Ratory handle ,Spreader terminal and phase barrier - 01 No. (b) Supply, installation, testing and commissioning of Soft Starter60 H.P. (c) Supply, installation, testing and commissioning contactors, relays, CT timers, for suitable rating having with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM along with contactor & semiconductor fuses with , Control Fuse etc fitted in Panel board for showing V, I, Hz, Pf 11 Supply, Installation, commissioning and testing LT paneloutdoor cubical floor mounted channel typeopenable to front and back both side side made out of 3.15 mm thick CRCA sheet dulypowder coated complete with bus barsize not less than 40x5mmrating made of Aluminium strip duly drillled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50Hz power supply system suitable for and including the following. Make of panel Legrand, Schnieder , L&T Note:- Panel shall be as per IEC -61439 part I & IIand TTA approved. (A) INCOMER(i) MCCBDU 200 Amp 4 Pole 50 Hz 415 Vwith rupturing capacity 25 KA. -01 Nos as incomer Make L&T Cat part No CM90634OOPO Conforms to IS/IEC 60947-2 & IEC 60947-2l Adjustable Overload Setting: 0.8 - 1.0 x In (B) OUTGOING (ii) MCCB DU 160 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25KA. -01 Nos as outgoing Make L&T Cat part No CM90634OONO Conforms to IS/IEC 60947-2 & IEC 60947-2l Adjustable Overload Setting: 0.8 - 1.0 x In(iii) MCCB DU 125 Amp 4 Pole 50 Hz 415 Vwith rupturing capacity 16 KA. -02 Nos as outgoing Make L&T Cat part No CM90634OOMO Conforms to IS/IEC 60947-2 & IEC 60947-2l Adjustable Overload Setting: 0.8 - 1.0 x In(iv) On load changeover160 Amp 4 pole Make L&T -01 No(v) Indicator set RYB 01 set of 3 pcs. (vi) Digital votmeter of size 96 x 96 mm range 30 to 600 volts of AE Make or equivalent of Make L&T with in built in selector switch 01 Set.(vii)Digital ammeter of size 96 x 96 mm range 0 to 500 amps of AE Make or equivalent of Make L&T with in built in selector switch complete with CTs of appropriate ratio 01 Set. All accessories prewired with suitable size copper conductor cable/strip and suitable foundation as per manufactrurs recomendation. Note:-(i) Drawing of the panel will be approved by the Engr-in-charge (ii) Factory testing will be carried by the manufactrer in the presence of Engr-in-charge, Any changes in the design will be incorporated. 12 Supply and fixingHT feeder pillar boxoutdoor type factory made weather and vermin proof made out from 3.15 mm sheet supported with legs all across the panel made of angle iron 50x50x5 mm of size 1.2 mtrx1 mtrx1 mtr with 3 Nos required lengthAluminium bus bar of size 40x10mm or 400 Amps for11 KV , 11 KV post Insulator 6 Nos duly drilled hole for HT Cable connection including front and rear side openable with locking arrangment suitable for 11 KV HT and provision for incoming and out going HT cable connection including painting with two coats of smoke gray synthetic enamels paint over a coat of red oxide primer complete and providing security fence XPM jally type of 2 mtr height from ground level square type all rounded 2.5 mtr length with 9nos angle iron of 25x25x5mm of hight 2.25mtr (2mtr above ground 0.25 mtr under ground) including necessary location gate of same XPM jally all as specified and directed . Note:- Feeder piller box shall be mounted on brick platform built in PCC not less then 60 cm above ground level with suitable PCC foundation rendering 15 mm in CM (1:6), applying two coats and cement base paints and XPM jally supported on 9 nos angle iron with concrete base. 13 Construction in replacement of transformer platform size 3mx2mx1m from ground incl XPM jalli fabricated with angle size 50x50x6mm and two coat of aluminum paint over one coat of red oxide incl steps plinth protection and all other relevant works complete all as specified. 14 Installation only Transformer capacity 160 KVA on constructed platform incl transportation of same from MES Complex , connection of cables of HT anfd LT side of transformer all as specified and directed. Note Transformer shall supplied by MES and any damage during loading and unloading shall bear by the contractor without any extra cost. 15 M&L for steel tubular swaged pole type 410 SP-55 (11metre long) with 300 mmx 300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping, complete all as specified and directed. 16 M&L for steel tubular swaged pole type 410 SP-31 (9metre long) with 300 mmx 300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping, complete all as specified and directed. 17 M&Lof cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. 18 Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation laying of pole stay assembly and laying of LT/HT cable and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge 19 All as per serial item No 18 above but depth exceeding 1.5 m and not exceeding 3 mtrs. 20 Returining filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed. 21 Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point. 22 Supply and laying sub class B bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid. 23 Material and labour for sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. 24 M&L for Cement concrete(1:4:8) type D-2 (using 40 mm graded aggregates) in sub- base and foundation filling for poles as mass concrete, complete all as specified and as directed. 25 M&L for Cement Concrete (1:3:6) type C-2 using 40 mm graded crushed stone aggregates for foundation filling of stays or poles as mass concretecomplete with necessary form work required complete all as specified and as directed by Engineer in Charge. 26 Fabrication ofCGI sheet openshedof size 12x9 for accomodating LT panels, voltage stabilizers , Includingangle iron truss ,PCC INCLUDING MS Pipe 100 mmdia for post flooringand brick work upto 5 feet height from ground and above 4 feet welded jali 4 mm diato be used total height of the shed is 9 feet from ground flooringcomplete all as specified. 27 Material and Labour for trial bore hole suitable for250 mm boreMS casing pipe in any type of strata including soft / hard rock by air hammer tool DTH Rig with /ODEX methodand getting out complete all as specified and directedfor upto 25 mtr depth below ground level. Note:- (i) The diameterof the bore hole should be sufficient large enough for lowering well assembly of 250mm casing pipe. Note - (a) The exact location of bore well shall be indicated by the engineer-in-charge based on the CGWB report available with the department at the time of commencement of work on ground.(b) The rate quoted shall deemed to be inclusive of hire charges of machinery, loading unloading, cost of fuel,other lubricants, transportation of all tools, moblization of machine, demoblization after completion of work of machine and accessories complete. (c) For the payment purpose only single unit of work for trial bore shall be measured & paid. (d) Necessary mandatory clearance from the concerned statutory /governing body or J&K PHE ground water department as the case may be shall be obtained by the contractor before commencement of work and the fees / charges on this account shall be deemed to be included in the rate quoted against Items.(e) Depending upon the avialability of water bearing strata if drilling beyond 100 m depth is required, the same shall be carried out after taking order from GE and rate for drilling beyond 100m depth shall be paid at the rates quoted for srl item No 4. (f) Verticality of the borewell shall be supported with verticality test certificate before lowering of casing pipe.The cost of verticality test is deemed to be include in unit rate. 28 All as per Item No 27 above but depth from 26 to 50 mtr below ground level. 29 All as per Item No 27 above but depth from 51 to 75 mtr below ground level. 30 All as per Item No 27 above but depth from 76 to 100 mtr below ground level. 31 Supplying, assembling and lowering 250 mm nominal bore mild steel ERW ISI marked casing blind pipe having wall thickness 6.4 mm as per IS-4270-1992 and jointing with electric arc welding, in random length of 3 to 6 metre, jointing and painting with two coats of bituminous paint of external surfaces of pipe upto maximum depth of 100metre below ground level complete all as specified and directed. 32 M&L for well cap fabricated out of 6mm thick MS Sheet for 250mm dia bore pipe in two piece having 80mm dia hole in centre with external bracket of flat iron of size 100mm x 6mm thick complete with nuts and bolts and washers etc. including painting with two coats of black bitumenious paint over a coat of red oxide primer complete all as specified and directed. 33 S&F housing clamp for 200mm dia MS ERW pipe made out of flat iron 100 x 12mm thick with required bolts, nuts washers including painting with two coats of black bitumenious paint over a coat of red oxide primer complete all as specified and directed. 34 Supply and fixing MS cutting shoe suitable for 200 mm dia as per requirement ofodex attachment all as specified and directed. 35 Development of borewell as per IS-2800 by means of compressor of min 250 PSI capacity air compressor untill the sand free water is obtained from the well for an uninterrupted period of 16 hours in a cycle of 24 hours.The final discharge shall be free form sand to deliver minimum 3 PLS of water and carrying out necessary yield test by V notch method and submitting the test report complete all as specified and directed by Engr-in-Charge. 36 M&L for chemical/bacteriological analysis and potablity test of water obtained from borewell from approved lab and submitting the report in triplicate all as directed and specified. 37 Foundation for holding borewell assembly of size 1000 x 1000 x 1000 mm at ground level made of PCC 1:2:4 type B2 using 40 mm (graded crushed stone aggregate ) with GI piipe 80 mm boree medium grade ( at three places, embedded through out the block 1.70 m length for feeding gravels and GI plug and socket fixed on top all as directed and specified. 38 Supply, lowering, connecting and commissioning of submersible pumpset radial flow multistages(V6) complete with electric motor suitable for 3 phase, 415 volt 50 HZ AC size(50 HP)star ratedsuitable to be lowered in 250 mm dia bore well and having discharge capacity 2600 LPMat 120 m head complete stainless steel SS-125 body and SS-410 impeller) all as specified and directed Make Kirloskar, KSB, CRI 39 M& L forflat submersible electriccable 3 core 10 sqmm with stranded copper conductor cable including water proof joints with motor leads connected to panel board all as specified and directed. 40 Supply, laying and testing of Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint incl jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 150mm bore class K-7 laid in trenches complete all asspecified and directedMake Electrosteel casting Ltd or equivalent in TATA, JINDAL. 41 Construction of valve pit ofsizes 120cmx120cmx120cm (internal dimentions), brick construction, including all necessary excavation and earth work in hard/loose soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4) rendering, 12 mm thick cement mortar (1:4), internally, finished even and fair pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint complete all as specified. 42 Supply and fixing sluice valve size 150mmcast ironISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it, class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation , packing rings, joiniting materials nuts,bolts, washers , gaskets and packings material all as specified and directed. 43 Supply and fixing non return valve 150 mm dia heavy duty both ends flanged ISI marked, class PN 1.6 complete with nuts, bolts washers etc complete all as specified and directed by Engr-in-charge . 44 Supply , lowering and testingGI water heavy duty size 80mm dia with with flanged both sides cut to size for accomodating submersible cable ,incl all fittings, such as rubber gasket set complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 1
Jammu And Kashmir View Result →
39.
Tourism #9312772 Technical Bid
Supply Of Mountaineering Ski And Rescue Equipment Supply Of Mountaineering Skiing Rescue Equipment To Jim And Ws , Multipurpose Shoe: (A) Must Be Plastic Double Boot For Cold, High-Altitude Climbs. (B) Should Come With A Durable Pebax® Shell That Remains Flexible Even In Bone-Chilling Temps. (C) Should Have High Altitude Liner To Provide Expedition-Worthy Warmth. (D) Should Be Lightweight And Flexible Pebax Shell (E) Must Have Rocker Sole For Easy Walking (F) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Climbing Shoe: (A) Should Be A Multifunctional Climbing Shoe Ideal For Beginners And Instructions Walls. (B) Should Have A Quick Lacing Hook & Loop Closure, Standard Fit. (C) Upper Material Should Be: Slip Lasted, Suede Leather. (D) Weight Should Be Approximately 300-400 G. (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Ski Rental: (A) Should Feature The Top Technology With A User-Friendly Geometry For All-Mountain Skiers. (B) Must Have Lyt Tech Construction (C) Should Have Emc, Era 3.0, And Graphene Technology. (D) Should Have Carbon Sandwich Cap Construction (E) Must Have Karuba Light Weight Wood Core (F) Structured Uhm C Base With All Ride Rocker (G) Tail: 121 Mm, Width: 85 Mm, Tip: 139 Mm (H) Turning Radius: 10.1 M (I) Sizes: 145, 155, 160, 165, 170Cm. (J) Binding System: Binding And Mounting Included. (K) Bindings Should Come With Maximum Safety With Full Heel Release (Fhr) Technology Which Should Significantly Reduce The Risk On Knee Injury. (L) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Snow Board Rental: Model: Rental Through All Of The Hybrid Board Experiments, Rocker Profile Tweaks, And Wild-Shape Designs, The Classic Camber And Predictable Performance Has Stood The Test Of Time. • Worked To Develop A Familiar And Stimulating Board For All Terrain. • The Colors Of The Soles May Be Different Depending On The Size Of Snowboard. • A Familiar And Stimulating Board For All Terrains. Binding All-Mountain Snowboard Binding More Than Holds Its Own Against Any Binding On The Market And Over-Delivers For Durability, Performance, And Value. The Mid-Flexing Binding Is Built On Our Rugged Profusion™ Chassis With Seamless Eva Foot Beds And A Built In 3º Cant To Provide Premium-Style Comfort While Putting The User In A Natural Athletic Riding Position For Absorbing And Attacking Terrain. In Addition, The At Nylon High Back Features Our Gap Eraser™ Forward Lean Adjustment, Eliminating The Need For A Standard Lock Block And Allowing You To Customize The Level Of Board Response - More Contact Equals More Response. The Power Ramp Easily Slides In And Out To Perfectly Match The Outsole Shape Of Your Boots For Quick Power Transfer On Take-Offs And Control On Rails. Our Padded Custom Caddi™ 3D Ankle Strap Is Cushy And Securely Hugs Your Feet While Allowing You To Tweak And Flex On Grabs And Presses, And The Perfectfit™ Toe Strap Features A Hinge Design That Can Be Custom Shaped To Any Snowboard Boot Toe Box Shape. • Category: All Mountain, Freestyle. • Sizes: S, M, L • Binding Flex: 4-10 • High Back: All-Terrain Boot A Snowboard Boot That Is Much More Than You Bargained For And A Noted Over-Achiever In Our Snowboard Boot Collection. Built With The Tech You Need From Companies You Trust, We Partnered With Boa® And Intuition® To Give You The Bang-For-The-Buck You Are After. The H4 Coiler Boa® Fit System Uses Stainless Steel Boa® Laces To Provide A Secure Closure With An Effortless Twist Of A Dial. The Integrated Intuition® Comfort Foam 3D Liner Naturally Forms To The Shape Of Your Foot And Is Constructed With Internal J-Bars To Hug And Cushion Your Ankles. We Pair This Heat-Moldable Liner With Our Easy-To-Use Fast-In Liner Lacing For A Premium Fit. • Free Style • Powder • All Mountain • The H4 Coiler Boa® Fit System • Fast-In Liner System • Flex Zone Upper Cuff Note: Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Snow Board Advanced : Board Backcountry Kickers, Side Hits Galore, Fresh Cord -- The All-New K2 Embassy Has Your Back For Wherever You Take It. Engineered With Versatility In Mind, This Directional All-Mountain Snowboard Has Become An Instant Classic Amongst Our Staff And Team Riders. The Heart Of The Embassy Snowboard Is The Bap Core, Consisting Of Bamboo, Aspen, And Paulownia - Sustainably Harvested To Provide A Smooth Feel And Snappy Flex That’S Built To Stand The Test Of Time. The Combination Camber Profile Adds Just A Bit Of Rocker To The Nose And Tail For A Predictable Feel In Deep Snow And Smooth Butters.We Sandwich The Core With Icg™ 10 Biax Fiberglass With Tip-To-Tail Carbon Stringers For High-Speed Stability And Edge Hold Through Choppy Terrain And A Little Bit Of Taper For A Classic Feel That Gets You Out Of Your Turns With Silky Precision. • Shape: Directional • Profile: Combination Camber • Snowboard Shape Notes: Traditional Shape • Base: Sintered 4000, Stone Finish, Sintered Base • Snowboard Core: Bap • Snowboard Glass: Icg 10 Biax Glass With Carbon • Snowboard Additive: Bio Resin • Snowboard Inserts: 2 X 4 Binding The All-Mountain Snowboard Binding Is The Perfect Place To Start. True Board Flex And Unrivaled Response With Multimount™ Ankle Strap Positioning, Allowing You To Customize Your Flex And Feel.Injected With A Castor-Bean Based Materials, The Am1 Is Equal Parts Eco And Lightweight. All-Mountain-Focused, Asymmetrically Shaped, And A Predictable Middle Of The Road Flex Pattern.Injected With A Castor-Bean Based Materials Our Sd1 Ankle Strap Is Lightweight And Offers A Fitting Blend Of Flexibility And Response.A Dual-Density Toe Strap Designed To Shape To The Contour Of Any Snowboard Boot – Manufactured Out Of Castor-Bean Based Materials. • Category: All Mountain, Freeride, Freestyle • Binding Flex: 6/10 • Highback: Single Density Castor Bean. • Pc Profusion™ Chassis Boot We Designed The Maysis To Perform Like A Workhorse And Fit Like A Glove, And Its Feature-Forward Design Has It Ranked As A Perennial Bestseller. Our Maysis Wide Snowboard Boot Features A Last And A Shell That Are 7Mm Wider Than A Traditional Snowboard Boot. It’S Success Starts With A Heat-Moldable Liner, Made Of Open-Cell Intuition® Foam - Allowing The Liner To Form To The Exact Shape Of Your Leg, Ankle, And Foot For Superior Fit, Warmth, And Comfort. The Secret To The Award-Winning Fit Is Our Conda™ Liner Lacing System. Powered By A Boa® Fit System Dial, This Forgiving And Adjustable Harness Is Designed To Pull The Users Heel Into The Boots Heel Pocket. This Urethane-Based Harness Hugs Your Ankle And Flexes Naturally. Externally, We Started With An Articulating Cuff To Reduce Distortion When Bending The Knee, And Weve Added An Abrasion-Resistant Rubber Compound For Unrelenting Durability. A High-Powered Boa® Fit System H4 Coiler Closes The Shell Securely And Can Be Done Without Ever Removing Your Gloves. • Category: Boa®, Conda™ • Boot Flex: 7/10 • Snowboard Boot Upper: Articulating Cuff, Endo™ Construction, Rubber Reinforced • Boot Liner Extras: Internal J -Bars, External J-Bars,Cored Ankle Pockets • Boot Liner Construction: Intuition® Control Foam 3D,Recycled Coffee Mesh • Boot Liner Lacing: Single Destiny Asym Conda™ • Boot Footbed: Harshmellow™ Plus Insole • Boot Outsole: This Grips!™ Premium Rubber,Harshmellow™ • Boot Lacing: Tx3 Boa® Lacing,H4 Coiler Boa® Fit System • Note: Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Snow Board Racer: Board Fis With The New Alpine Worldcup (Fis), A Snowboard That Is Optimally Adapted To The New Conditions In Racing. The Consistent Application Of The Shape Technology Gives The Rider Full Control Over The Board As Usual. With The Newly Developed Torsion Power Control System (Tpcs), Even More Energy Can Be Stored In The Swing, Which Then Dynamically Supports The Swing Change. The Adapted Geometry Allows Maximum Speed At The Exit Of The Turn. Success Is Pre-Programmed. • Clothbound Sidecut • Sandwich Titan Construction • Optimized K.Tec X Woodcore • Abs Sidewalls • Sintered Base • Length: 156Cm, 162Cm, 177Cm, 186Cm • Inserts For All Flex Plate Binding The High-End Plate Binding For Racers And Extreme Carvers. Improved Power Transmission And Flex Performance Due To New Bail Geometry. • 3 Sizes For Perfect Flex Performance • Quick And Direct Power Transmission • Anodized Titanium Coating For Excellent Looks And Corrosion Resistance • Stiff Side Flex Especially For Very Narrow Boards And Steep Binding Angles • Eds-Shock Absorption System For Full Control • Extremely Stable Due To Extra Thick 5.9 Mm Stainless Steel Bails Boot A Hardboot Is Available In Shell Sizes A, B, C, D And In Two Different Harnesses. From Mondo Point 23.0 To 29.5With Grilamid®, Which Has A Very Low Heat Reaction And Very High Strength. Optimized Geometry And Design, For Ideal Function And More Precise Adjustment • Reinforced Mechanics • Infinitely Adjustable Tilt Angle • Hardness Adjustment With Different Springs • Stronger Back Mechanic • Variable Angle Of Inclination Exchangeable Springs For Hardening Adjustment Note: Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Ice Skates: (A) Should Have A Softboot® Design. (B) Should Provide Comfort And Breathability. (C) Should Be Backed Up By The Stability Plus Cuff Which Provides Ample Support And Flexibility. (D) Should Be Perfect For Year-Round Skating At The Rink Or Winter Skating On Frozen Ponds With Water Repellant Materials And A Warm Brushed Lining To Keep Skating In Comfort. (E) Should Have The Injection Locked Stainless Steel Blades, Pre-Sharpened And Keep You Gliding Smooth And Edging Clean On The Ice. (F) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Skiexercise Trade Mill: It Should Be The Ultimate Ski Fitness Machine For Advanced And Professional Skiers. The Training Should Work On The Principle Of Weight Transfer, Balance And Agility, Which Builds Strength Through The Lateral Motion. • Must Be Compatible For Advanced And Professional Skiers • Should Help With Ski Fitness, Balance And Agility • Features Should Include: Tilted Rotating Frame, Which Simulates Carving Ski Turn Perfectly • Should Include: Pro Ski App - Provides Technical And Performance Analysis Of Your Trainings • Should Focus On Leg, Core, Arms And Shoulder Strength, While Providing Joint Stability And Mobility • Should Be Low Impact Cardio Exercise, Safe To Use In Joint Rehabilitation • Should Offers 6 Intensity Levels And Two Training Modes (Slalom And Giant Slalom) • Must Be Suitable For Fitness, Ski Clubs And Also Home Use • Dimensions And Weight Of The Palette:L 195Cm X W 55Cm X H 137Cm, Weight 175Kg • Assembled:L 192Cm X W 130Cm X H 110Cm, Weight 143Kg • Should Include: Professional Hand Holder, Race Frame, Pro Ski App, Rotation Platform, Ski Simulator All In One Cart • Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Snow Board Exercise Trade Mill: Snowboard Simulator Should Focus On Building Base Strength And Endurance Necessary For Hitting The Slopes Much Better. Simulator Should Be A Great Off And Pre-Season Conditioning Trainer & Great For Balance, Coordination And Improving Technique Throughout The Winter Season. • Should Be Suitable For Alpine And Freestyle Snowboarders • Must Be Enabled To Mimic Turns Which In The Past Could Only Be Achieved On The Snow • Should Be Low Impact Exercise And A Perfect Choice To Prepare For The Next Winter Season • Should Focus On Building Your Base Strength And Endurance Necessary For Hitting The Slopes Much Better • Simulator Should Be Great For Balance, Coordination And Improving Technique Throughout The Winter Season • Portable Machine, Should Be Suitable For Indoor And Home Us • Dimensions And Weight Of The Package:L 178Cm X W 70Cm X H 30Cm, Weight 42Kg • Assembled:L 173Cm X W 68Cm X H 125Cm, Weight 40Kg • Should Include:Basic Frame, F-Type Cart, Hand Holder, Complete Workout System Support • Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Micro Traxtion: (A) Should Be Compact And Lightweight Progress-Capture Pulley Designed For Crevasse Rescue, Hauling, And Self-Rescue, And For Use As An Emergency Ascender. (B) The Cam Should Belocked In The Open Position So The Device Can Be Used As A Simple Pulley. (C) Min. Rope Diameter: 7 Mm (D) Max. Rope Diameter: 11 Mm (E) Sheave Type: Sealed Ball Bearings (F) Sheave Diameter: 27 Mm (G) Working Load: 2 X 2.5 = 5 Kn (H) Breaking Strength: 2 X 7,5 = 15 Kn (I) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Mini Traxtion: (A) Should Be An Openable Progress-Capture Pulley That Allows The Rope To Be Installed While The Pulley Is Connected To The Anchor. (B) The Cam Should Belocked In The Open Position So The Device Can Be Used As A Simple Pulley. (C) Material(S): Aluminum, Stainless Steel, Nylon (D) Min. Rope Diameter: 7 Mm (E) Max. Rope Diameter: 11 Mm (F) Sheave Type: Sealed Ball Bearings (G) Sheave Diameter: 32 Mm (H) Working Load: 2 X 2.5 = 5 Kn (I) Breaking Strength: 2 X 10 = 20 Kn (J) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Pro Traxtion: (A) Should Be Possible To Open, Even When Attached To The Anchor, The Pro Traxion Progress-Capture Pulley Must Be Designed For Setting Up Haul Systems. (B) Should Have A Large Diameter Sheave Mounted On Sealed Ball Bearings And Excellent Efficiency, (C) Material(S): Aluminum, Stainless Steel, Nylon (D) Min. Rope Diameter: 8 Mm (E) Max. Rope Diameter: 13 Mm (F) Sheave Type: Sealed Ball Bearings (G) Sheave Diameter: 38 Mm (H) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Paw Riging: (A) Material Should Be Aluminum (B) Range: Rigging Plate (C) Weight: Approximately 188 Grams (D) Dimensions: 173.6 X 84.5 Mm (E) Aperture: 20 Mm And 23.5 Mm (F) Working Load: 9 Kn (G) Breaking Load: 45 Kn (H) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Rope Grab: (A) Must Be An Aluminum Mobile Fall Arrest Device With Swiveling Side Plate. (B) Should Easily Follow The Operator Both Up And Down And Lock In The Event Of A Fall. (C) Range: Fall Arrest (D) Should Be Compatible To Use With Mobile-Lanyard With Two Anchoring Positions. (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Rescue Double Pulley : (A) Should Be A Twin Pulley With Two Sheaves Mounted In Line On Ball Bearings For Intensive Zip-Lining Use. (B) Material Should Be Aluminum (C) Must Have Two Sheaves Mounted On Ball Bearings Ensure Consistently High Performance Regardless Of The Users Weight (D) Additionally, To Ensure Traceability, Each Pulley Should Have An Individual Number. (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Auto Lock Carabineer:(A) Must Be Asymmetrical 3-Matic Triple Action Screw Gate Carabineer For Lanyards. (B) Should Be Compatible To Use With A Belay System Or During A Rappel. (C) Must Ensures That The Descender Is Always Well Guided At The End Of The Carabineer. (D) Material Should Be Aluminum (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Pair Type Carabineer: (A) Should Be A Large Hms Belaying Carabineer With Triple Action 3 Matic Locking Gate. (B) Must Be Suitable For Hms Belays And Double Rope Maneuvers, Such As Capstan Or Half-Capstan. (C) Should Have A Large Working Surface Which Makes It Easy To Disengage Even Wet Ropes (D) Should Have A Key Lock System, Which Is Also Suitable For Belaying And Top Roping. (E) Material Should Be Aluminum (F) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Power Ascender: (A) Must Be Battery-Powered And Motorized System To Ensure The Transport Of Persons Or Loads To Areas That Are Difficult To Access And Where Occasional Or Recurring Work Is Carried Out. (B) The Operation And Use Of The Acx Should Be Able To Be Learned In Special Training Courses. (C) Energy Source: Poa-004 Power Supply, Removable Battery. (D) Max. Ascent Rate: 24 M/Min. (E) Maximum Descent Speed: 25 M/Min (F) Working Load Limit: 220.00 Kg (G) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Expansion Bolts With Rings: (A) Should Be A Simple Top Anchor Device With 10 Mm Bolt Hangers And Mix Of Single And Double Ring Bolts. (B) Use Cases: Sports Climbing, Canyoning, Equipment (C) Weight: 208G (D) Main Material: Stainless Steel (E) Main Color: Colorless (F) Weight: 95G (G) Total Length: 10.4Cm (H) Depth: 95M (I) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Heavy Sound Whistle: (A) Whistle Up To 142Db Loud, Should Have Very Long Range, For Mountain Instructors. (B) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Special Big Umbrellas For High Altitude Mountains: (A) Resistant To Heavy Rain, Snow, Winds In High Altitude With Manual Opening. (B) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Rock Pitons (Vertical, Horizontal, Multipurpose, Diagonal): (A) Features: Rock Piton With Different Dimensions Should Be Made Of Hardened Steel For Granite/ Limestone. Tough Enough To Withstand Repeated Abuse In Thin To Medium-Width Cracks. (B) Hot Forged Lightweight For Strength And Size With Numbered For Quick Identification (C) Material Should Be: Nicrmo Steel / Ktl-Coated. / Equivalent Or Better. (D) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Megaphone: (A) Should Be A Rugged Megaphone, Built To Defy Water Damage, Sinking, Corrosion, Cracking, And Splitting. (B) Should Be Able To Be Used For Up To A Full Day On A Single Charge. (C) Must Have: P-67 (Excludes All Dust And Water For 30 Minutes At 3.3Ft / 1M Submersion). (D) Dependent Upon Volume And Continuity Of Operation. 8 Hours Typical Operation – Defined As Speaking 35% Of The Time At Volume Level 6 1/2 Hours. (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Megaphone Batteries: (A) Must Be Rechargeable Lithium-Polymer Battery. (B) Should Have Lithium-Polymer Battery Pack 11.1Vdc Typical, 8 W/Hr. (C) Additionally Should Have Charger Input Voltage: 90-264Vac, 50-60Hz, 7 Watts; Universal Input Capable – Compatible With All World Currents With Appropriate Adapter Plug. (D) 80% Rated Capacity After 300 Charge/Discharge Cycles 60% Rated Capacity After 500 Charge/Discharge Cycles. (E) Charging: 0°C To 45°C / 32°F To 115°F (F) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Rucksack :Capacity 80 Litres (Including Detachable Day Pack) Frame Internal Frame With Hard Fibre Support And Aluminum Rod Usage Ideal For Long Duration Mountain Treks/ Rain Cover Included Inside The Velcro Pocket At The Base Of The Rucksack Fabric Material 250 Gsm Water-Repellant Pu Coated Polyester Buckle Material Delrin Webbing Material Polypropylene Dimensions 78*35*28Cm (When Fully Filled) Weight 1-2 Kg Compartments Top Section With Zipper (Ideal For Handy Items Like Eye Wear, Medicines) 1. Main Upper Compartment 2. Main Lower Compartment - Separate Bottom Opening, To Be Used For Storing Soiled Clothing, Emergency Items Or Shoes 3. Spacious Deep Pockets On Each Side 4. Mesh Pockets On Each Side 5. Easily Detachable 12-15 Litre Day Pack On The Front 6. Laptop Sleeve Features • Hard Fiber Support In The Back Along With Aluminum Rod Provides A Strong Internal Frame • Extra Soft Breathable Cushioning On The Back Provides Easy Air Flow While Walking For Long Hours • 8 Utility Straps To Wrap Additional Items (Sleeping Bag, Mat, Camping Equipment) On The Sides, Bottom And Top • Elastic Cords And Hooks On The Day Pack To Hold Mountaineering Gear And Additional Emergency Items • Elastic Loops For Holding Trekking Poles • Double Layered Strong Fabric At The Bottom Provides Durability For Rough Usage And Carrying Excess Load • Base Pads On The Bottom Protects From Rough Terrain Load Management • Torso Adjustment Straps To Fit Variable Heights And Physiques • Chest Strap With Elastic Provides Movability And Aids In Adjusting Load • Four Load Setting Pulls On The Shoulder Straps • Flexible And Movable Waist Strap To Fit Below The Pelvis Area , Gaiters: (A) Gaiters Should Have Construction Which Is Abrasion And Water-Resistant To Keep Debris Out, Regardless Of Footwear Choice When Traveling Through The Mountains Or Desert. (B) Should Have 100% Nylon Fabric Is Tough And Abrasion-Resistant, And The Polyurethane Coating Adds An Extra Layer Of Protection Against Moisture. (C) Must Have Boot Lace Hooks, An Elastic Bottom Edge, And A Durable Hypalon Instep Strap Keep The Gaiters In Place While In Use, While The Top Closure Buckle Ensures A Snug Fit. (D) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Prussic Cord: (A) Must Have A Diameter Of 6Mm (B) Material: Polyamide (C) Sheath Material: Polyamide (Pa) (D) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa , Ice Piton Warthog (Cord- Hanger): (A) Cord Hanger Ice Screw Is The Old Version Of Ice Screws From Warthog Family Of Ice Pitons. (B) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Rope Rappelling (Static): (A) Should Be The Longstanding Benchmark Rope For Work At Height. (B) Material: Polyamide (C) Low Impact Force: 5.30 Kn (D) Breaking Load: 3000 Dan (Kg) (E) Static Elongation: 3,0 % (F) Percentage Of Sheath: 38 % (G) Percentage Of Core: 62 % (H) Knotted Strength: 1800 Dan (Kg) (I) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Mittens: (A) Made Up Of Heavy Duty Canvas For Rough Use. (B) Strong, Durable, And Versatile. (C) Palm And Thumb With Double Layered Canvas And Padding Protection From Heat Generated During Long Rappels Or Lowers. (D) Ergonomic Cut For High Dexterity Without Being Too Tight. (E) Weight- Up To 200 G. (F) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Chock Powder: (A) Should Be Very Smooth And Dry Magnesium Carbonate Powder. (B) Fine Magnesium Carbonate Powder That Spreads Well Over The Hands And Doesn’T Clump. (C) Main Material: Magnesium Carbonate (D) Color: White (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Multipurpose Shoe Inner Laces : (A) Should Be Resistant Laces (B) Must Be Durable (C) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Multipurpose Shoe Outer Laces : (D) Should Be Resistant Laces (E) Must Be Durable (F) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Rental Ski Wax: (A) Should Be Fluor Free (B) Should Be All Condition Wax. (C) Compatible For All Snow Types. (D) Color: White. (E) Should Be Bio Degradable. (F) Universal Hydrocarbon Wax For All Skis And Snowboards. (G) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Ski Press: (A) Minimum Voltage: 220 Volt. (B) Must Be 1,000 Watt (C) Should Be Compatible For All Types Of Skis And Snowboards (D) Must Have Easy Temperature Adjustment (E) Should Be Supplied From A Renowned Brand/ Company Of More Than 10 Years Of Experience Of Supplying This Type Of Item And Certified By Ce En, Ukca And Uiaa. , Crampon Carry Bags Foldable: (A) Crampon Bag Should Be In Fabric Resistant To Cuts, Abrasions And Punctures. (B) Should Have A Large Double Zip Opening, And A Net On One Face Designed To Dry Crampons Faster. (C) Must Have A Reinforced Bottom That Protects The Contents Of Our Backpack From The Sharp Points Of Crampons
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
40.
Public Administrative Department #9243419 AOC
Supply Of Medical Equipment And Instruments ( 2023-2024, 2024-2025 Two Years ) , Fogger Machine For Fumigation & Disinfectant Tasks ( High Power Jetain Watts Inpleallarfansystem 600 Watts-5 Ltr Tank Capacity , Boyles Appratus ( 2 N2o Provision Safty N2o Cuttoff, O2 Failure Alarm ) :- Specification :- • Anesthesia Work Station With Vantilator & Veporiser ( Qty-01 ) • Diamention:- 1356Mm X 845Mm X 620Mm • Two Gas Machine With Oxygen & Nitrus Oxide With Each Yoke • Vantilator Should Be Minium 8 Inch Touch Screen With Tidal Volumn 20Ml To 1500Ml, Suports Vantilator Mode Iipv, Pcv, Simv-Vc, Manual, Ps / Cpap ( With Apena Backup, Standby ) . • Vanylation Monitaring:- Pressure:Ppeak, Pplat, Peep, Pmean • Volumes:-Mv, Vt Respiratory Freq. Compliance Etc • Waveform Display P-T, F-T, V-T • Sutable For Adult &Paed. • Should Be Double Tube Machanical Flowmeter For Each Gas . • Suport Two Veporiser Mount & Two Drawers • It Should Be Ce Certified. • Alaram -High / Low Airway Pressure, High / Low Minute Volume, Power Failuer, Oxygen Supply Failure, Apnea, High / Low Fio2 Specification :- ? Anesthesia Work Station With Vantilator & Veporiser ( Qty-01 ) ? Diamention:- 1356Mm X 845Mm X 620Mm ? Two Gas Machine With Oxygen & Nitrus Oxide With Each Yoke ? Vantilator Should Be Minium 8 Inch Touch Screen With Tidal Volumn 20Ml To 1500Ml, Suports Vantilator Mode Iipv, Pcv, Simv-Vc, Manual, Ps / Cpap ( With Apena Backup, Standby ) . ? Vanylation Monitaring:- Pressure:Ppeak, Pplat, Peep, Pmean ? Volumes:-Mv, Vt Respiratory Freq. Compliance Etc ? Waveform Display P-T, F-T, V-T ? Sutable For Adult &Paed. ? Should Be Double Tube Machanical Flowmeter For Each Gas . ? Suport Two Veporiser Mount & Two Drawers ? It Should Be Ce Certified. ? Alaram -High / Low Airway Pressure, High / Low Minute Volume, Power Failuer, Oxygen Supply Failure, Apnea, High / Low Fio2 , Baby Radint Warmer With Inbuilt Led Phototherapy Unit • Should Be Micro Controller Base, • Should Control Servo Skin , Pre Warm & Manual. • No Need Of Calibration Required For Temprature Prob. • Heater Modual Should Rotates 90° To Both The Sides To Facitate. • Phototheapy Light Sourc At List 24 Blue Led, 3 White Led. • >Irradiance 45 Uw / Cm2 / Nm At A Distance Of 30Cm. • Should Be Compatible For X-Ray Procedure. • Should Be Iso 13485:2016 , Standard Examination Couch. Size: L 1830Mmxw575mmxh850mm Frame Crca Rectangular Tube. Crca Sheet Cabinet. One Cabinet &One Drawer With Lock Sliding Step Stool &Writing Pad. 100Mm Thick Reversible Foam Mattress. Stainless Steel. , Gyanec Examinaton Table: Size L1820mmxw560mmxh815mm. Frame Bend Press Crca Sheet Top With Back Rest Adjustable On Ratchet. Perinial U Cut At Foot End .Crca Tubular Legs .Step Stool &Mattress .Lithotomy Bars With Stirrups. Stainless Steel. , Myo’S Trolley Tray Size- 410Mmxlx560mm W Stainless Steel, Height Adustment From 890 Mm To1400 Mm, 50Mm Diameter Wheels , Seating Arrangement: Four Seater 72” Length. , Adult Weighing Machine , Adult Weighing Machine , Instrument For Paediatric And Neonatalweighing Scale For Neonatal , Oxygen Hood, S And M, Sector 0 Each Including Conneting Tubes , Resucitor Hand- Operated Nenonatel- 250 Ml , Larygoscope Hand- Operated Neonatel – 500Ml , Larygoscope Set, Neonatal , Suction Machine Foot Operated , Neonatal Pulse Oxymeter , Electronic Weighing Scalefor Baby 10G<5 Kg , Stethoscope For Neonates- Binaural , Electronic Spygmomanometer , Electronic Mobile Light Examination Mobile ( 220-12 V ) , Vinyl Coated Measuring Tap – 1.5 M , Basic Kidney Tray- Stainless Still ( 825 Ml ) , Infusion Stand Withdoubblehook On Castors , Glucometer With Sugerstrips , Sugerstrips , Nebulizer Pulmoaid Type Heavy Duty. Isi Mark. , Re-Breathing Bag With Valve .05 Ltrs. , Re-Breathing Bag With Valve 2 Ltrs. , Laryingo Scope With Ambubag Silicon Caff White Adult. I.S.I Marks. , Electric Sterilizer Stainless Steel Medium Sizes Marks I.S.I , Plaster Cutting Scissor , Plaster Cutting Machine Electric , Plaster Spreader , Silicon Ambubagwith Tubing, Mask , Nebulisation Mask Pediatric , Nebulisation Kit Big , Nebulisation Kitsmall , Needle And Syringe Destroyer ( Hub Cutter ) , Ilr Refrigeratorwiththermometer Ice Lined Refrigerator With Dual Interior Layer Design With Built In Ice Packs To Maintain The Temperature Of The Refrigerator Double Walled With Inner Chamber Made Of S.S. And Outer Of Thick Pcrc Sheet Duly Enamels Painted. Temprature Range From Ambient To -2°C To 8°C Is Achieved By Hermertically Sealed Compressor. Body Mounterd On A Study Angle Iron Frame And Is Mounted Orcaster Wheels. Unit Is Fitted With Solid State Digital Tempreatureindicator- Cum-Controller 6 Cuff. ( 180 Liter ) , Tunning Fork , Knee Hammer S.S. Handle , Instrument &Machines. For Dental Department. Electro- Surgical Cautatory Machine For Dental Use Only Coltence-Valdent Type , Air Rotor Hand Pieces. ( Kavo / Nsk ) , Composite Material Kit. ( Ivoclar-Teric M Cream ) Aesthatic Kit ( Shelf Life ) , Apex Locator Root Zx-Ii , Pro-Taper Files Total - ( Sx, S2, F1, S1, F2 ( 25 Mm Length ) , Teflon Coated Composite Hand Instrument Set , Diamond Burs ( Cavity Cutting ) Set ( 1X5 ) , Mummifying Agent , Glass Inomomer Cement Type -Ix Gc Large , Glass Inomomer Cement Type -Ii , Sponge Holder 10 , Suction Tips. ( Silicon ) , Suture Cutting Scissor , Extraction Forceps Sets ( Pedo ) / Routine Forceps Set , Mouth Mirror ( Anti- Fogging ) , Pro Taper Gutta Parch Filling Material- 6% ( F1, F2 ) ( Gp Points ) , Twizzer , Routine Gp Point ( Red, Yellow, Blue ) , Probes , R.C. Help , Rotary Root Canal Smart Systemdensply Sybron Endo , Rvg System With Laptop And Printer , Dental Loops , Dy Cal , Rct- / H-Hand Files 10 / 15 / 20 / 25 , K Files Hand , Rct-Sealer ( Resin Based ) Ah-Plus , Dental X-Ray Machine , R.C. Cal ( Calcium Hydroxide ) , Root Canal K-Files ( Dentsply ) , Gas Torch With Refill Culinders , Root Canal Dressing Cement Premixed , Lingnocaine Inj Gun For Cartridges With Aspiration , Advance Dental Chair With Accessories Programe Attachment Features: 1.Left-Handed Dental Chair 2-Body- Contoured Electrically Operated Dental Chair With Zero Programme With Right Arm Rotatble ; 6- Programmes 3- Led Operating Lilght Having 30000Lux On / Ofanfintensitucinto By Non Touch Sensor With 3 Directional Movement 4- Chair Side Proreclain Spittoon With Auto Water Connection 5- High Ns Low Vcummotorized :Dryco” Susctionwith Auto Drain And Autoflush System 6- Modular ( Delivery Hanging System ) 7- Airotor Points – 2 Nos. 8- Supreme Micromotor 35000 Rmp With Digital Display Of Speed 9- Beecool Turbo Light Cure 10- Ss Instrument Tray 11- X-Ray Viewer 12- Ultra-Sonic 13- Light Cure Attachment Specification • Electric Lly Operable • Seamlessnseat Upholstery • Ceramic Spittonand Tumble • Halogen Light Packing • Dental Chair With Sto • Ceramic Spitton& Tumbler • Halogen Light • Instrument Tray • Foot Control • Two Threewaysyring • Provision For Three Airotor& A Micdromotor , Instrument For Gynecology / O.T Department Hydraulic Opertion Table With All Function Genral Surgery Specification:- 1. Size – 72 X 24 X 30 2. Table Type – Hydraulic 3. Hight Adjustable Range ( In Mm ) – 750-1000Mm 4. Trendelenburg ( Indegrees ) : + / -25 Degree 5. Table Length – 1900Mm 6. Material – Stainless Steel 7. Table Width ( In Mm ) – 520Mm 8. Lateral Tilt – 20 ( Degree Both Side ) 9. Leg Section–90 ( Degree Down Manual ) 10. Head Suction: + / -60 Degree 11. Back Section : + / -60 Degree 12. Floor Locking System- Manual 13. Center Pillar 14. Inbuild Kidney Bridge 15. Five Sectional Radio- Translucent , Hi- Pressure Steam Sterilizer With All Accesessories • Shape & Dimension : Cylindrical To Fit 3 Drums Of Size 15”X 12” • Capacity : 200 Liters. Size: 20” X 39” ( 500Mm X 1000Mm ) • Mode Of Heating : Electrically Heated By Water Immersion Haters Of 18 Kw Electric Load Wired For Operation On 3-Phase 4-Wire, 400 / 440 Volts 50 Hz. A.C. Supply. • Working Pressure : 30 Lbs / Squ. Inch. 2.20Kgf / Cm2 / Adjustable. • Operation Pressure : 2.10+0.15 Kgf / Cm2 ( 30Psi ) / Adjustable. • Operating Temprature : About 134 Degrees Centrigrade And / Or Adjustable. • Exhaust : Fast Exhaust Withing 1 Minute & Slow Exhasut From 7 To 30 Minutes. • Performance : The Sterlizer Should Be Capable Of Performing The Following Operations Constituting One Full Cycle Of Strelization. • Material Consturction : The Material Should Be Ss Sheet Of Grade 304, Jacket, Boiler, End Ring, Piping & Conecctions, Dished Door, Outer Cover • Multiport Valve : To Control The Cycle Of Strelization As Per Bis Standards. • It Should Be Fitted Safety Valve, Ejector, Drying System, Vaccum Breaker, Plug Screen, Tempreature Gauge, Pressure Gage, Compound Gauge, Steam Trap, Strainer And Check Valve • Boiler ( Steam Generator ) : Fitted To Underside Of Jacket. • Tray ( Stainless Steel ) : Provide In The Chamber Of The Suitable Size. • The Whole Unit Should Mounted On A Tubular Pipe Stand With Levelling Flanges And Duly Painted With Best Heat Resisting Epoxy Paint. , Nerve Locator With All Necessary Accsessories , Operatontheators Shadowless Lamp Celling Model ( 4+3 Petal ) Specification:-Should Be A Surgical Light Unit Incorporating The Latest Led Technology Shadowless Operatinh Light Field With The Following Specifications. A ) Shouldd Have Double Colour High Performance Leds With Life Time More Than 50, 000 Hours. B ) Should Be A Dual Dome And The Main Light And Satellite Should Have The Following Specifications C ) Lux Intensity 1, 35, 000 Lux & Satellite 1, 35, 000 Lux Or Above. D ) Light Field Diameter Should Be Above 210 Mm Or Better. E ) Colour Temperature Should Be Between 3800 To 5000 Degree K F ) Colour Rendering Index Should Not Be Less Than 93 G ) Depth Of Illumination Should Not Be Less Than 125 Cm. H ) Lllumination Adjustment 30% To 100% With Field Indication. I ) Led Done Should Have At Least 8 Nos Of Yellow Leds To Achieve Warm White Light For Surgeons’ Comfort. J ) Each Arm Should Have 320-Degree Rotation K ) Linear Intensity Control Should Be Provided On Main As Well As Satellite Done. L ) White And Yellow Led’S Should Have Individual Control With The Help Of Remote Control. M ) Each Dome Should Have 4 Reflectors With Aluminium Body To Dissipate Heat. I. Intensity Of Each And Yellow Light Should Be Controlled By Feather Touch Button On Dome Arm As Well As By Wirless Remote Control. Ii. Total No Of High Intensity Led’S In Each Dome Should Not Exceed 48 Nos.Led Dome Should Have At Least 8 Nos Of Yellow Led To Achieve Warm Whit Light For Surgeons’ Comforts , Operation Theater Shadow Less Lamp Celling Model ( 3 Petal ) [ Specifiction : As Per Same Above Tender Item No. 79 But This Item Is For 3 Petals ] , Stand Lamp Light With Moving System Shadowless K Floor Model , N.S.T. Machine For Gynocology Dept Usespecification :- Trolley Mounted, Table Top, Features, With Hart Rate Monitor, With Printear, Approx. Weight- 3To 4 Kg, Power Consumption < 20 Watt. , Laproscope For T.L. With All Accessories. Specification – Double Puncturescope, Reusable, Refurbished, For T. Gynacoligy Surgery, Material S.S., Led Light Source With Fibre Optic Cable, Veress Needle, Ring Applicatror And Multifunction S.S. Trocar. , Sim, S Speculumset Large, Medium, Small ( Stainless Stell 304 Certificate Is Must ) 1 Set In 3 Nos ) , Digital Fetal Monitor Doppler Specification:- 1. Size - 135Mm X 95Mm X 35Mm 2. Weight – 500Gm Including Battery Weight 3. Display – 45Mm X 25Mmlcd 4. Battery – 2 Pices Of 1.2V Recharable Battery 5. Performance Parameter – Working Frequancy Of Ultrasonic Is 2.5Mhz, ±10% Nominal Standered , 200Mm Distance From Prove, Intergrated Sensitive >_90Db, Display Range 50-230Bpm ( ±2Bpm ) , Tooth Forceps , Delivery Forceps ( Outlet Blade ) , Bipolar Cautary Machine ( Eclipse ) , M.T.P. Suction Machine ( Electric ) Isi Marks , Vacuum Extractor ( Vacuum For Delivered With Silasble Cup- Metallic Cups ) , Cu S Cos Speculums ( Stainless Steel 304 Certificate Is Must ) , Sim, S Speculum Set Of Large, Medium, Small ( Stainless Steel 304 Certificate Is Must ) , Curved Artery Forceps Size-6 ( Stainless Steel 304 Certificate Is Must ) , Vulcellum Forceps , Curved Mosquito Artery Forceps Size-6 ( Stainless Steel 304 Certificate Is Must ) , Needle Holder Size-6 ( Stainless Steel 304 Certificate Is Must ) , Scissors 8 Straight Only , Stout Scissors 8” , Tailor Scissor Big , Curved S.S Scissor Size-6 ( Stainless Steel 304 Certificate Is Must ) , Curved S.S Scissor Size-8 ( Stainless Steel 304 Certificate Is Must ) , Sharp Scissor Size-8 ( Stainless Steel 304 Certificate Is Must ) Stiles ( Curved ) , Curved Sharp Scissor Size- 8 ( Stainless Steel 304 Certificate Is Must ) Stout , Stainless Steel Dressing Drums- Size – 12”X 15” , Stainless Steel Dressing Drums- Size – 9”X 11” , Stainless Steel Dressing Drums- Size – 9”X 9” , Stainless Steel Dressing Drums- Size – 6”X 6” , Stainless Stell Tray With Cover Size- Large , Stainlesstray With Cover Size- Medium , Stainlesstray With Cover Size- Small , Enamal Tray Size – 20”X14 Without Cover , Enamal Tray Size – 13”X15” Without Cover , Instrument For Laboratory Hot Air Oven Specification- Size- 18X18x18 Two Tray 400 Kw, 230V, 4 Amp With Digital Display &Timer. , Incubator Specification- Size- 18X18x18 Two Tray 400 Kw, 230V, 4 Amp With Digital Display &Timer , Binocular Microscope • Provide With Binacular Observation Head Inclined At 45 Degree Rotable Through360 Degree And With Interpupillary Asdjustment. • With Hygenianeye –Pieces 10X, 15X ( Paired ) Achromatic • Objectives: 5X, 10X, 45X &100X Oil Immersion ( Spring Loaded ) Detachable Mechanical Stage. • Magnification : 50X To 150X , Centrifuge Machine- Specification- 16 Tubes With Digital Display &Timer. , Fully Automedrandam Access Clinical Chemistry Analyser With Ups 1- Indian Made 2- 200 Test / Hour 3- Table Model 4- 45 Hard Glass Cuvettes , Semi Auto Biochemistry Analyser Specification :- Mono &Bichromatic Measurement Photometric Range From 0 To 3.0 Od Photometric Resolution Up To 0.0001 Automatic Zero Setting Static Photometer : 340-630 N.M. Wavelength : 340, 405, 505, 546, 578, 630 N.M. Mult-Point Calibration With Graphical Display Levy-Jennings Graph For Quality Control 1000 Test Patient Pesults Storage Peristalitic Pump Aspiration System With Calibration Facility Dual Cuvette System: • Flow Cell Volume-33?L • 10 Mm External Glass / Polystyrene Aspiration Volume From 350 To 999 ?L Tempreature Control At 25°, 30° & 37° C Repeat Measurement By Read Key Collated Report Date Wise, Id Wise ( Alphanumeric ) Inbuilt Thermal Printer Direct Printer Connectivity Through Usb Port Usb Connectivity To Pc Connectivity To External Incubator ( Optional With 16 Position ) , 3 Part Hematology Analysertotal Parameter :22 Total Parameter :22Specification:-The Instrunment Should Be Fully Automated 3-Part Differential With 22 Parameters Offering Automatic Start Up, Shutdown And Sample Analysis I. The Instrument Should Have Cyanide Free / Colorimetric Method For The Hemoglobin Measurement. Ii. The Instrument Should Report Minimum 22 Parameters Including, Wbc, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Plt, Lym#, Mid#, Grant#, Lym%, Mid%, Grant%, Rdw-Sd, Rdw-Cv, Pdw-Sd, Pdw-Cv, Mpv, Pct, P-Lcc, P-Lcrwith Three Histograms-Wbc, Rbc, Plt Iii. The Instrument Should Have A Throughput Of 60 Samples / Hour Iv. The Instrument Should Have Around 50, 000 Searchable Sample Data Storage. V. The Instrument Should Have Colored 10.4” Lcd Touch Screen With Intuitive Menu Icons For Easy Operation Vi. The Instrument Must Have Provision To Incorporate Morphological Findings & Other Test Results Like Blood Group & Rh Type, Esr, C-Reactive And Reticulocyte Counts Etc. In The Instrument Report Printout Vii. The Instrument Should Have In-Built Thermal Printer And 4 Usb Interface For Connecting External Printer, Keyboard, Mouse, Barcode Scanner Viii. The Sample Volume Should Not Exceed 9 ?L In Manual Mode, 20?L In Pre-Dilute & Capillary Mode Each Ix. To Ensure Economy As Well As Better Reagent Inventory Management, The Number Of Reagent Types “That Are Required To Be Connected To The System” For Operation Should Not Xceed 2 Types Preferably ( Excluding Calibrators, Controls And Other Ancillary Reagents That Are Not Required During Each Sample Analysis ) X. Instrument Should Have In-Built Real Time Inventory Management System To Track Usages Of Reagents Xi. Instrument Should Have Facility To Auto-Dispense Pre-Defined Volume Of Diluents For Pre-Dilute Mode Xii. The Company Supplying The Instrument Should Hav A Good Track Record And Excellent Service And Distributor Network All Over India. Cbc, Wbc, Rbc, Hgb, Hct, Mcv, Mch, Mchc.Pdw-Cv, Rdw-Sd’Plt, Mpv, Pct, Pdw-Cv, Pdw-Sd, Plcr, P-Lcc, 3 Part Diff:Lymp% & #, Mid%&# Grab%&# Throught – 60 Test / Hr. Histogram- 3 ( Wbc / Rbc?Plt ) Data Storage 50, 000 Result With Graps Quality Control -500 Files With L-J Grapj X-Bar Analysis , Electronic Shaker For Lab , Manual Vacuum Aspirator With Carman Canula. , Electric Fumigation Machine For O.T Fumigation Isi Mark , Vision Chart With Plain Mirror. , Trial Box Set , A Scan Biometer Technical Specification :- • Transducer Prob:- • Frequencey -10Mhz + 10% • Fixation- Internal Red Led • Modes- Auto + Save • Measurment Range-Manual 15 To 45Mm Axil Length • Display :- 7” Tfl Display With Touch Screen • Power :- 100-240 Vac, 50-60 Hz, 0.3A • Diamention ( Wxhxd ) :- 8”X5.5”X2.5” • Accessories :- • Usb Thermal Print • Foot Swith • Power Adopter ( 5V, 4A ) • Immersion Shell With Tubing , E.N.T. Microscope-With All Accessories Specification. 1 ) Microscope Body Withapochromatic Optic Having 5- Stepmagnification Changer. 2 ) 12.5 Wide Field Eye Pieces With Locking Diopters 3 ) Objectives 200Mm, 300Mm, 40Mm 4 ) Manual Binocular Tube With 200 Mm Focal Length. 5 ) Tiltable Binocular Tube With 200 Mmfocal Length. 6 ) Movable Floor Mounted Red Dot Stand With Locking Casters. 7 ) 100 Watt 12 Volt Halogen Illumination In Stand With Easy Change Overfacility For The Back Up With Halogen Lamp / Or Led. 8 ) Microscopic Arm Should Be Minimum One Meter In Length. , C- Arm Machine With Table 9 Inch With Stabilizer • Mobail Surgical C- Arm With 9 Inch Immageintenicifire With 3.5 Kv High Frequency Genrator, •2 Monitors / 1 Hd Monitor • Pc Work Station, •Ability To Store More Than 1000 Immages • Application For Orthopedic, Urology, Neorology& Gastro Etc , Drill Machine For Ortho Battery Oprated ( Bell / Manman / Metronik ) , Micro Ear Instruments, , Auto Reftractometer ( Computor For Eye Checkup ) Technical Specification :- • This Equipment Should Be Usefull For Finding Out Automatic Reading Refraction &Kerometer. • Auto Alignement Auto Focus. • Retraction :- 1.Sphere Range :- Minus 25 Plus 22 Dioptersapprox 2. Cylinder Range: Zero To Ten Dioptersapprox 3. Axis Range : 1 To 180° • Keratometry • Corneal Curvature Radius 5Mm To 10Mm Aprox • Corneal Refraction 66 To 33 Dioptersaprox • Built In Printer Facilityshould Be Available • It Should Be Able To Gove Reading With Pupil Size Min2mm • Motoritized Table Should Be Supplied To Keep The Auto Refractometer • Digital Display • Usp Backup , Opthalmic Microscope With Assitant Scope & Integrated Hd Camera Attachment Specification :- • Main Microscope • Binacular Tube – Parallel 45°Inclimedbinacular Tube • Objective Lence – F=200Mm • Eye-Pice -12.5X • Magnification Change Type- Drum Type With Five Change • Total Magnifiaction- 3.4X, 5.3X, 8.5X, 13.5X, 21.2X • Field Of Vew –Ø66.2, Ø42.4, Ø26.5, Ø16.6Ø10.6Mm • X-Y Translator ( Option ) Range :±25Mm • Arm Counter- Balance • Length –F=200Mm • Rotation Angle -12.5X • Column Base • Base Diamention -740Mm • Power Unit: • Primary Voltage Ac100-120 / Ac220-240V • Pawer Frq. :- 50-60Hz • Max Pawer Consuption :-180Va , Remote Control Distance Snellen Chart , Ent Opd Instrument Set , Electronic Shaker For Lab , Post Mar-Tum Set ( Mfg By Tuft ) , Slit Lamp , Double Door Cupboard Type Refrigerator Capacity 868 Ltr , Abg Machine , Defibrilator Machine With Standard Accessories ( For Icu Unit ) ? Monophasic Defibrillator ? Lcd Display 5.7’ ? Event Recording ? Thermal Printing Specification: ? Energy Select With External Internal Paddles ? Charge Led Indicator On Front Panel ? Sync Mode Indication Message On Monitor Screen ? Integrated Adult & Paeditaric Paddles ? Ecg Out 1V / Mv ? Defibrilator Protection , Proctoscope Medical Instrument , 3 K.V. Online U.P.S. , 5 K.V. Online U.P.S.
Contract Date: Jun 22, 2026 Contract Value : 1.05 Crore
Government Departments No of Bidders 15
Maharashtra View Result →
41.
Public Administrative Department #9053889 Technical Bid
Tender For Construction Of Bphu At Chakulia Rural Hospital Under Goalpokher-Ii Development Block- CIVIL WORKSurface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. PWD SOR: 1/1 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete (a) Depth of excavation not exceeding 1,500 mm. PWD SOR: 1/2 3 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation PWD SOR: 1/3 4 (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) PWD SOR: 2/4 5 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. PWD SOR: 47 / 3 6 Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS- 6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.) PWD SOR: 5/10 7 (d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated) PWD SOR: 6/10 8 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturers specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). PWD SOR: 47 / 1 9 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. PWD SOR: 14 / 1 10 (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] Ground Floor (a) 1:3:6 proportion PWD SOR: 34 / 22 11 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (i) Pakur Variety a) Gr Flr and Foundation 12 b) First Floor 13 c) Second Floor 14 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. PWD SOR: 43/40 III.Other thanSAIL/ TATA/RINL (a) For works in foundation and upto roof of ground floor/upto 4 m 15 (b) in first Floor 16 ( c) in second floor 17 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) Steel Shuttering9 to 12 mm thk approved quality plyboard shuttering in any concrete works direction of Engineer-In-Charge. PWD SOR: 42 / 36 a) in foundation and Gr Flr 18 b) in First Floor 19 c) In 2nd Floor 20 Brick work with 1st class bricks in cement mortar (1:6) PWD SOR: 15/8 a) in foundation & plinth 21 b) in superstructure Gr Floor 22 c) in First Floor 23 d) in 2nd Floor 24 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. PWD SOR: 16/16 a) in ground floor 25 b) in first floor 26 c) in second floor 27 Labour for Chipping of concrete surface before taking up Plastering work. PWD SOR: 182 / 1 28 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] PWD SOR: 189 / 1 (i) With 1:6 cement mortar (b) 20 mm thick plaster I) in Gr Flr 29 II) in 1st Flr 30 III) in 2nd Flr 31 (c) 15 mm thick plaster I) in Gr Flr 32 II) in 1st Flr 33 III) in 2nd Flr 34 (ii) With 1:4 cement mortar (c) 10 mm thick plasterI) in Gr Flr 35 II) in 1st Flr 36 III) in 2nd Flr 37 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. PWD SOR: 192 / 15 38 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement PWD SOR: 48 / 6(ii) 25 mm. thickIII) in 2nd Flr 39 In ground floor (Plinth Protection) 40 Extra cost of labour over grey artificial stone for (i) Chequering PWD SOR: 49 / 8 41 Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturers specified rate) for concrete of various grades. PWD SOR: 45 / 9 42 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour PWD SOR: 66 / 36 43 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] PWD SOR: 54 / 17 44 Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 Square meter. 45 In First floor (c) Area of each Granite slab above 1.00 Square meter. PWD SOR: 34 / 63 of 315 46 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. PWD SOR: 64 / 35(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white 47 (B) WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white 48 Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) Inner Walls PWD SOR: 198 / 5 I) in Gr Flr 49 II) in 1st Flr 50 III) in 2nd Flr 51 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface. PWD SOR: 195 / 7 52 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. (b) TwoCoats PWD SOR: 196 / 8I) in Gr Flr 53 II) in 1st Flr 54 III) in 2nd Flr 55 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer Super Protective 100% Acrylic Emulsion Two Coats PWD SOR: 197 / 17I) in Gr Flr 56 II) in 1st Flr 57 III) in 2nd Flr 58 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. PWD SOR: 117 / 8 59 PVCDoor Shutter-37 mm thick Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc. In ground floor. PWD SOR: 133 / 26I) in Gr Flr 60 II) in 1st Flr 61 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor (Payment will be made on the area of the gate covered by two guard rails and two extreme channels) PWD SOR: 106 / 18 62 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. PWD SOR: 105 / 16III) in 2nd Flr 63 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr PWD SOR: 104 / 13I) in Gr Floor 64 II) in First Floor 65 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) PWD SOR: 109 / 22 66 (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. PWD SOR: 200 / 1a 67 A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface With super gloss (hi-gloss) (iv) Two coats (with any shade except white) PWD SOR: 200 / 2A 68 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. PWD SOR: 245 / 15 69 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white PWD SOR : 246 / 16 70 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film PWD SOR: 233 / 1 I) Natural white h) Louvered windowi) Top, bottom and side member 71 ii) Louvered Section. 72 iii) Cleat angle ( Non-annodized). 73 g) Fixed glazing.i) Top, bottom and side member 74 ii) Mullion. 75 iii) Glazing clip. 76 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: PWD SOR: 145 / 29 (vii) 100 x 75 x 4.0mm 77 Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Chargeii) 100 mm. PWD SOR : 243 / 12 78 Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units: PWD SOR: 239 / 2iv ) Fixed glazing. 79 v ) Louvered window. 80 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. PWD SOR: 243 / 9i) 4mm thick clear glass. 81 viii) 8mm thick coloured / tinted / smoke glass. 82 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.C) Both side decorative lamination (II) Interior Grade (ii) 12mm PWD SOR: 177 / 13 (c )I) in Gr Floor 83 II) in First Floor 84 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (iv) 125 mm grip x 10 mm dia rod. PWD SOR : 145 / 30 85 Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws PWD SOR : 144 / 26(vii) 225mm long x 10mm dia. bolt. 86 iv) 150mm long x 10mm dia. bolt. 87 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. PWD SOR : 141 / 10(b) 250mm long. 88 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. PWD SOR : 213 / 21A) UPVC Pipes: (ii) 110 mm. Dia. 89 a) Plain Tee(ii) 110 mm. Dia 90 b) Plain Y(ii) 110 mm. Dia. 91 c) Bend 87.5 degree(ii) 110 mm. Dia. 92 d) Shoe(ii) 110 mm. Dia 93 Design, Fabrication, Supply,Delivery (factory to health facility) and Fixing of Vinayl Printed Signage/Display board ( Size of board 4 X 5 sqft - 1 nos. .) , fabricated with 16 SWG rectangular MS angle / flat iron structure. Facia to be made of 1.5 mm ACP sheet and Logo, Color,lettering style etc. will be made as per approved specification which is to be digitally printed on Vinayl sheet by computerized inscription. Vinayl printed sheet to be fixed on ACP sheet. Ready signage to be fixed on wall/roofby 50x50 mm angle iron or as per site requirementincl. The matter is to be done as per approved specification. Non-Schedule. As per rate analysis. 94 SANITARY AND PLUMBINGSupplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) PWD SOR: 12 / 19 (I) (a) For Exposed Work PVC Pipes 1. 40 mm 95 (b) For Concealed Work1. 15mm 96 2. 20mm 97 3. 25mm 98 Supplying, fitting and fixing Peets valve fullway gunmetal standar dpattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). PWD SOR: 4/I-4i) 15mm dia 99 ii) 20mm dia 100 iii) 25mm dia 101 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 PWD SOR: 29 / 1(b) 15mm 102 Supplying, fitting and fixing bib cock or stop cock. PWD SOR: 6 / 7 (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). 103 (d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). 104 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity PWD SOR: 37 / 6 105 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. PWD SOR: 36 / 2 106 Labour for punching hole in plastic water storage tank upto 50 mm dia.PWD SOR: 38/13 107 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets (ii) 550 mm X 400 mm size PWD SOR: 41 / 1 (ii) 108 Supplying, fitting and fixing White Vitreous China Sink in position on C.I. (b) Laboratory sink with rim and overflow (i) 450 mm X 300 mm X 150 mm PWD SOR: 42 / 5(b)(i) 109 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (ii) 450 mm long PWD SOR: 43 / 9 110 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long PWD SOR: 43 / 10 111 Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand). PWD SOR: 44 / 16 112 Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). PWD SOR: 45 / 19 113 Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). (iii) 150 mm PWD SOR: 66 / 16(iii) 114 Supplying, fitting and fixing with cement jointing (3:1) with jute gasket soaked in cement mortar PWD SOR: 67/17(a) Stoneware bend(iii) 150 mm 115 (b) Stoneware single T or Y junction(ii) 150 mm 116 Supplying, fitting and fixing C.I. round grating(i) 100 mm PWD SOR: 67/18 117 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm PWD SOR: 68 / 23 118 Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. PWD SOR: 74 / 24(A) Above ground(ii) 110 mm dia 119 (B) Under ground(ii) 110 mm dia. 120 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 PWD SOR: 70 / 23viii) Double Y with Door(b) 110 mm 121 xi) Door Bend (T.S.)(b) 110 mm 122 xv) Vent Cowl(b) 110 mm 123 xvi) Pipe Clip(b) 110 mm 124 (ii) Plain Tee(b) 110 mm 125 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With P trap PWD SOR: 79 / 2 126 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. PWD SOR: 81 / 10(a) E.W.C.(ii) Plastic (hallow type) white 127 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe PWD SOR: 81 / 11 128 Supplying, fitting and fixing liquid soap container PWD SOR: 82/17 129 Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm PWD SOR: 82 / 19 130 Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass(i) 25 mm dia. and 450 mm long PWD SOR: 82 / 22 131 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL) PWD SOR: 87 / 1 (7th Corri) 132 Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. PWD SOR: 89 / 4 - 7th Corri 0 mm thick dry brick work and 250 mm thick cement brick work (1:6) and With 25 1.00m inside dia. (SAIL/TATA/RINL) (Other than SAIL/TATA/RINL) 133 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (ii) For 20 users A) With Pakur variety. (SAIL/TATA/RINL) PWD SOR: 88 / 3 - 7th Corri 134 (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety] Ground Floor (a) 1:3:6 proportion PWD SOR: 34 / 22 135 Supply fitting and fixing Fire Exyinguisher Conforming to ISI marked ( IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 kgs. Capacity , with initial filling in brand new cylinder with poder coated finish , fitted with gun metal union , discharge hose , wall mounting bracket and suitable sinage etc. complete ( Make: Fire Shield / New age / De Flame / Andex or equivalent ). A level should be pasted on the body of the Extinguisher duly signed & stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/ Date of next refilling.( warranty card need to be submitted ) 136 DG SETEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete (a) Depth of excavation not exceeding 1,500 mm. PWD SOR: 1/2 137 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. PWD SOR: 14 / 1 138 (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) PWD SOR: 2/4 139 (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] Ground Floor (a) 1:3:6 proportion PWD SOR: 34 / 22 140 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (i) Pakur Variety a) Gr Flr and Foundation 141 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. PWD SOR: 43/40 III.Other thanSAIL/ TATA/RINL (a) For works in foundation and upto roof of ground floor/upto 4 m Reinforcement (0.8% of concrete) 142 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) Steel Shuttering9 to 12 mm thk approved quality plyboard shuttering in any concrete works direction of Engineer-In-Charge. PWD SOR: 42 / 36 a) in foundation and Gr Flr 143 Brick work with 1st class bricks in cement mortar (1:6) PWD SOR: 15/8 a) in foundation & plinthBrick work (1:6) 144 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] PWD SOR: 189 / 1 (i) With 1:6 cement mortar (b) 15 mm thick plaster I) in Gr Flr 145 GST 18 % (FOR CIVIL WORK,S&P,DG BASE) 146 CESS 1% (FOR CIVIL WORK,S&P,DG BASE) 147 ELECTRICAL PART (SCHEDULE ITEM)SUB-HEAD I: INTERNAL WIRING All wiring Item including provision of conduit, conduit accsories , circuit wiring, switch, box and all fitting completed as required. INTERNAL WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall tolight/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr 148 Average run 7 mtr 149 Average run 8 mtr 150 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed] Average run 9 mtr 151 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2x36/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 152 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Power & 20A Board] 153 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [A.C. Point] 154 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [HTPN DB to SPN DB] 155 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [UPS] 156 3x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as Neutral, ECC [FUSE BASE to LT Panel] 157 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5 sqmm 158 4 sqmm 159 6 sqmm 160 16 sqmm 161 CONDUIT PIPESupplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).19mm dia 3mm thick Polythene Pipe 162 25mm dia 3mm thick Polythene Pipe 163 Cutting Channel of size (31 mm x 31 mm) on RCC plastered ceiling by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles19 mm dia 3 mm thick polythene pipe without earth continuity wire 164 Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles25 mm dia 3 mm thick polythene pipe without earthcontinuity wire 165 SWITCH BOARDSDistn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board 166 Average run 6 mtr 167 Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Havells/Legrand/L&T-Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [CPU Board] 168 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Havells/Anchor/Legrand-Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 20A Plug Point] 169 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Havells/Anchor/Legrand-Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Power Board] 170 Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Havells/Legrand/L&T-Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [AC Board] 171 TPN D.BSupplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens/L&T).6 way [Enclosure (LTTD06N)] [EDB-1, Gr. Fl., EDB-2, NDB-2, 1st Fl.] 172 8 way [Enclosure (LTTD08N)] [NDB-1, Gr. Fl.] 173 Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts boltsetc incl. provision for earthing attachment.6 way HTPN DB 174 8 way HTPN DB 175 SPN D.BSupplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand / Havells / Siemens/L&T)(2+16 Way) Enclosure [ELDB1-Gr. Fl., ELDB 2-1st Fl.] [Enclosure (607713)] 176 (2+12 Way) Enclosure [LDB 1Gr. Fl., LDB 2-1st Fl.] [Enclosure (607712)] 177 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. painting, connection & provision for earthing attachment4 Way [UPS: I/C & O/G] 178 MCB Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection(Legrand / Havells / Siemens/L&T) .Single pole 6-32A MCB [NDB 1,2, EDB 1,2, ELDB 1,2, LDB 1,2 O/G] 179 Single pole 32A MCB [EDB 1,2 O/G - ELDB 1,2] 180 Single pole 40A MCB [NDB 1,2 O/G - LDB 1,2] 181 Four pole 63A MCB Isolator [NDB 1,2 I/C] 182 Four pole 40A MCB Isolator [EDB 1,2 I/C] 183 Four pole 40A MCB [UPS 4 WAY I/C & O/G] 184 Double Pole 40A MCB Isolator [UPS O/G, LDB 1,2 I/C] 185 Double Pole 32A MCB Isolator [ELDB 1,2 I/C] Make-Legrand 186 SUB-HEAD III: SUPPLY & FIXING OF FANSSupply & Fixing Socket type fan regulator (Step type) (Havells/Anchor/Legrand-Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 187 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 188 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire along with fixing of safety rope 189 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12) 190 Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long)For Al : 30 cm Exhaust fan (12) 191 Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board 192 SUB-HEAD IV: SUPPLY, LAYING & FINISHING OF CABLELaying on Wall / surface with Saddles / clampsLaying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting 193 Laying in Underground TrenchLaying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoringsurface duly rammed 194 CABLE TERMINATIONSupplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core upto 50 sqmm 195 For 4 core upto 35 sqmm 196 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required65 mm dia ISI 197 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 198 4 core 35 sqmm cable 199 SUB-HEAD V: EARTHING:Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil 200 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe [D.G. Body:2, D.G. Neutral: 2, LT PANEL:2, UPS: 2] 201 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 202 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. 203 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 204 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid GI wireNo. 6 SWG 205 SUB-HEAD VI: TELE. TV & DATA POINTS:TELEPHONE AND NETWORKING BOARDSupply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required 206 Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. 207 TELEPHONE AND NETWORKING CABLESupplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. 208 Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. 209 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works20x10mm Size 210 Supplying & Fixing Out door type CFL/LED luminaire (Havells make-LHRC4185099 or equivalent) with deep drawn aluminium housing anodised inside & clear acrylic cover and accessories incl. for 85 watts CFL lamp / 20 watt LEDincl. S&F 32mm dia GI pipe bracket, clamp, nut & bolts etc. 211 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitablesize of MS fastener 212 Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 213 Fixing only lamp 214 Average District Charge 7% (On Scheduled items) (ELECTRICAL) 215 SUB-HEAD II: LT PANEL/DISTRIBUTION BOARDS LT PanelMain LT Panel :- Supply, delivery, installation, testing & commissioning of Indoor Cubical type L.T. Distribution panel board of required size, wall/stand mounted compartmentalized with maple arrangement having rigid & self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and 35x35x5 mm M.S. angle frame for panel mounting support and making necessary grouting arrangements with neet cementing finish as per direction of EIC. [Dim. - 1600mm x 1450mm x 350mm]. The panel board consisting of the following item:-415V, 200A electrolyte grade tinned copper BBC (Raw power Busbar & D.G. Busbar) with vertical section of 25X6mm sizefor neutral & Phases. Bus-bars shall be fixed with FRP insulator chair & seperator & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. [equal bar for each i.e. 4-bar]and interconnections for:- 125A SFU and all inter-connecting links should be made with suitable size copper strip/copper wire.A) Incomming Arrangement: a) 415V 50 Hz 125A TPN SFU (panel mounting cubicle type) conforming to IS 13947 in open execution three pole & neutral, Make- Legrand/Havells/L&T -01 no.B) Bus Section:415V, 200A electrolyte grade tinned copper bus bar, with vertical section of size 25x6mm for Phase RYB, neutral bars of each. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. - 02 nos.C) Outgoing Arrangement:a) 415V 125A MCCB Breaking Capacity:- 25kA/35kA with fixed thermal & fixed magnetic/adjustable thermal & fixed magnetic setting, panel mounting cubicle type conform to IS :13947, Make- Legrand/Havells/L&T-04 nos.b) 415V 125A TPN On load Changeover switch, front operated Changeover switch in open execution type, Make- Legrand/Havells/L&T - 01 no.c)Triple Pole 63A MCB (Legrand/Havells/L&T) -03 nos.d)Triple Pole 40A MCB (Legrand/Havells/L&T) -01 no.e)Double Pole 32A MCB (Legrand/Havells/L&T) -04 nos.f) Single Pole 6-32A MCB (Legrand/Havells/L&T) - 08 nos.D) Metering Panel:a) S&F 3-ph digital single function panel meter, Voltmeter (L&T)- 02 nos.b) S&F 3-ph digital single function panel meter, Ammeter (L&T) - 02 nos.c) S&F 200/5A 15VA Class-1 C.T. (KAPPA) - 06 nos. d) S&F Gen next LED phase R-Y-B indicator-Make-L&T 06 nos. e) S&F 6A SP MCB (c-curve)-Make-Legrand/Havells/L&T06 nos.f) S&F 08X06 Danger Board02 nos.E) Cable Alley:Cable entry arrangement will be provided in the cubicle panel in vertical position of size 1450mm x 350mm x 350mm with suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C.F) Painting:The complete panel board shall be painted by 2 coats of powder coated synthetic enamel paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C.G) Constructional Details:All incoming & outgoing panel mounted cubicle switch disconnector fuse shall be housed in respective compartment with hinged & gasketted door at front, All doors shall have panel lock arrangement. The panel shall be properly gasketted to prevent ingress of dust & moisture & remain. Busbar will be properly arrange & all switches shall be fixed by M.S. nuts & bolts on angle iron/flat iron frame base as per direction of E.I.C. 216 FUSE BASESupply of 2 mm thick wooden ply board of size 3 ftx2 ft and fixing the same in wall by necessary nuts, bolts etc. Incl. Supply and fixing of 3 nos. 100A, 415V, Porcelain Fuse carried and base (Havells make, cat no: IHKKRN4100) and neutral bar at wooden board. 217 SUPPLY OF FANSSupply & delivery of Sweep:- 48 (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA STRIKER PLUS or CROMPTON (with safety rope) [Approved by EIC] 218 Supply & delivery of Sweep:-36 (900mm) AC ceiling fan, 50-70 Watts, Speed:->=380 RPM, Air delivery:->=145 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA or CROMPTON or HAVELLS (with safety rope) [Approved by EIC] 219 Supply & delivery of heavy duty Exhaust Fan of Sweep:-12 (300mm), 240 volt, 50 Hz, AC , 50-60 Watts, Speed >900 RPM, Air delivery >=1145 CMM suitable for . [Make - Orient(Model:Power Flow)/EPC/Havells/Crompton Greaves] [Approved by EIC] 220 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells)50 sqmm 4 core (A2XWY/A2XFY) 221 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells)35 sqmm 4 core (A2XWY/A2XFY) 222 Supply & fixing of unipolar hexagonal flat mounting insulator for busbar support for fixing of neutral earth busbar at the side of D.G. foundation & location of UPS of the following specification:-i). Polyester without halogenii) UL94 VO self-extinguishing.iii) Colour red RAL 3002.iv) Operating temperature from -40 to +130°C.v) Deformation under load temperature (ASTM D643): > 200°C.vi) Dielectric constant (ASTM D150): 4/5.vii) Arc resistance (ASTM D495): > 180 s.viii) Water absorption (ASTM D570): < 0.3%. 223 SUB-HEAD VII: SUPPLY & FIXING LED LIGHTING FIXTURE for INTERNAL WORKSupply & delivery of single 4ft Batten type LED tube light fitting,1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Make:-Havells: LED Pride Plus NXT Batten 22 W 6500 K) or equivalent of Philips, Crompton etc. [Approved by EIC] 224 Supply & Delivery at site 9 watt LED Bulb,Efficacy>=90 lm/W, Base Cap:-B22 [Make-Havells, LED DEKOR BULB 9 W B22 CDL] or equivalent of Crompton, Philips etc. [Approved by EIC] 225 GST 18 % (FOR ELECTRICAL WORK) 226 CESS 1% (FOR ELECTRICAL WORK) 227 WBSEDCL Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
42.
Educational and Research Institute #9049929 Technical Bid
Rate Contract For Drugs And Medicines And Surgicals And Lab Kits , Medicines, Surgicals And Suturesitems : , Bupivacaine Hydochloride In Dextrose Injection Usp Each Ml Contains Bupivacaine Hydrochloride 5.0 Mg Dextrose 80.0 Mg , Bupivacaine Inj Ip 0.5% , Halothane Bp , Isoflurane Usp , Ketamine Inj Ip 50 Mg/Ml , Lignocaine Ointment 5 O/O , Lignocaine And Adrenaline Inj Ip Each Ml. Contains Lignocaine Hydrochloride Ip 20 Mg Adrenaline Ip 0.01 Mg , Lignocaine Gel Ip 2% , Lignocaine Inj Ip 2 O/O , Propofol Inj Ip 10 Mg/Ml , Thiopentone Inj Ip 0.5 G , Sevoflurane , Atropine Sulphate Injection 0.6Mg/Ml , Liquid Medical Oxygen (Lmo) , Diclofenac Sodium Inj Ip 25 Mg/ Ml (Im/Iv Use) , Diclofenac Gastro Resistant Tablet Ip 50 Mg(Enteric Coated) , Fentanyl Citrate Injection Ip 2 Ml , Ibuprofen And Paracetamol Tablets Ip Ibuprofen 400 Mg+Paracetamol 325 Mg , Ibuprofen Tab Ip 200 Mg (Coated) , Ibuprofen Tab Ip 400 Mg (Coated) , Morphine Sulphate Inj Ip 10Mg/Ml , Paracetamol Drops Paediatric Paracetamol Oral Suspension Ip(Each Ml Contains Paracetamol 150Mg) , Paracetamol Syrup Ip 125 Mg/5Ml (Detail In Rc) , Paracetamol Tab Ip 500 Mg , Paracetamol Inj. 150 Mg/Ml , Pentazocine Inj Ip 30Mg/Ml (Im/Iv Use) , Tramadol Cap Ip 50 Mg , Tramadol Inj 50 Mg/Ml , Indomethacin Cap Ip 25 Mg , Diclofence Prolonged Release Tablet Ip 100 Mg , Ibuprofen Oral Suspension Bp /Usp 100 Mg/ 5 Ml , Diclofenac Sod + Paracetamol Tablets Ip Diclofenac Sod 50 Mg + Paracetamol 325 Mg , Aceclofenac And Paracetamol Tablets Aceclofenac 100 Mg And Paracetamol 325 Mg , Diclofenac Gel: Diclofenac Diethylamine 1.16%, Methyl Salicylate 10%, Linseed Oil 3%, Menthol 5% , Etoricoxib Tab Ip 120Mg , Mefenamic Acid Tablets Bp 500 Mg , Fentanyl Citrate Injection 50Mcg/Ml , Naproxen Tablet Ip 500Mg , Naproxen Tablet Ip 250Mg , Etoricoxib Tablet Ip 90 Mg , Aspirin Tablet Ip (Gastro-Resistant) 150 Mg , Diclofenac Sodium Aqueous Injection 75Mg/Ml 1Ml Size, Iv & Im Use , Paracetamol Infusion Ip 1% W/V 100Ml Size , Ketorolac Tromethamine Dispersible Tablet 10 Mg(Each Uncoated Dispersible Tablet Contains Ketorolac Tromethamine 10 Mg) , Baclofen Tablet Ip 10 Mg (Each Uncoated Tablet Contains Baclofen Ip 10 Mg ) , Tizanidine Hydrochloride Tablet Ip 2 Mg (Each Uncoated Tablet Contains Tizanidine Hydrochloride Ip 2 Mg) , Adrenaline Injection Ip 1Mg/Ml Im/Iv Use , Betamethasone Tab Ip 0.5Mg , Chlorpheniramine Maleate Tab Ip 4Mg , Dexamethasone Inj Ip 8Mg/2Ml , Dexamethasone Tab Ip 0.5 Mg , Hydrocortisone Sodium Succinate Injection Ip 100 Mg Base / Vial (Im/Iv Use) , Hydroxyzine Tab Ip 25 Mg , Methyl Prednisolone Sodium Succinate For Injection Usp 500 Mg , Pheniramine Inj Ip 22.75Mg /Ml , Prednisolone Tab Ip 5 Mg , Promethazine Syrup Ip 5 Mg/5Ml , Promethazine Inj Ip 25Mg/Ml , Promethazine Tab Ip 25 Mg , Betamethasone Sod Phos Inj Ip 4Mg/Ml , Prednisolone Tablet Ip 10 Mg , Prednisolone Tab Ip 20 Mg , Anticold Syrup Each 5 Ml Contains Phenylephrine Hydrochloride 2.5Mg , Chlorpheniramine Maleate 1 Mg, And Paracetamol 125 Mg , Cetirizine,Phenylephrine & Paracetamol Tablets Cetirizine 5 Mg,Phenylephrine 10 Mg & Paracetamol 325 Mg Tab , Cetirizine Syrup Ip 5Mg/5 Ml , Levoceitrizine Tablet 5Mg , Montelucast(10Mg) + Levocetrizine Tablet (5Mg) , Dexamethasone Tablet Ip 4 Mg (Each Uncoated Tablet Contains Dexamethasone Ip 4 Mg) , Naloxone Inj Ip 0.4Mg/ Ml , Pralidoxime Chloride Injection Ip 25 Mg/Ml / 500 Mg , Acetylcystine Solution Usp (Injection) 200 Mg/Ml , Carbamazepine Tab Ip 200 Mg , Carbamazepine Tab Ip 100 Mg , Phenobarbitone Tab Ip 30 Mg , Phenytoin Injection Bp 50Mg/Ml , Phenytoin Oral Suspension Ip 25Mg/Ml , Phenytoin Tab Ip 100 Mg (Film Coated) , Sodium Valproate Gastro Resistant Tablets Ip 200 Mg , Phenobarbitone Inj Ip 200Mg/Ml , Carbamazepine Oral Suspension Usp 100 Mg/5Ml , Sodium Valproate Oral Solution Ip 200 Mg / 5 Ml , Sodium Valproate Tablet(Gastro Resistant) Ip 500Mg , Clobazam Tablet Ip/Capsule 5 Mg , Clobazam Tablet/Capsule 10 Mg , Levetiracetam Tablet Ip 500 Mg , Levetiracetam Oral Solution/Suspension 100Mg/Ml , Levetiracetam Injection 500Mg/5Ml , Gabapentine Tablet/Capsule 100Mg , Gabapentine Tablet/Capsule 300Mg , Lamotrigine Tablet Ip 50 Mg (Each Sustained Releasetablet Contains Lamotrigine Ip 50 Mg) , Divalproex Extended Release Tablet Ip 250 Mg (Each Extended Release Film Coated Tablet Contains Divalproex Sodium Ip Equivalent To Valproic Acid 250 Mg) , Oxcarbazepine Tablet Ip 150 Mg (Each Film Coated Tablet Contains Oxcarbazepine Ip 150 Mg) , Lacosamide Tablet 100 Mg (Each Film Coated Tablet Contains Lacosamide 100 Mg) , Topiramate Tablet Ip 25 Mg (Each Film Coated Tablet Contains Topiramate Ip 25 Mg ) , Acyclovir Oral Suspension Ip 400Mg/5Ml , Acyclovir Tab Ip 200 Mg , Acyclovir Tab Ip 800 Mg , Albendazole Oral Suspension Ip 400 Mg/10Ml , Albendazole Tablets Ip 400 Mg(Detail In Rc) , Amikacin Inj Ip 100 Mg , Amikacin Inj Ip 500 Mg , Amoxycillin And Cloxacillin Cap 250 + 250 Mg , Amoxycillin And Potassium Clavulanate Tabs Ip 500 Mg + 125 Mg , Amoxycillin Cap Ip 250Mg , Amoxycillin Cap Ip 500Mg , Amoxycillin Dispersible Tablets Ip 125 Mg , Amphotericin B Inj Ip 50 Mg , Ampicillin Injection Ip 500 Mg , Azithromycin Tab 100 Mg Dispersible Tabs (3 Tab Strip 10X3x3) , Azithromycin Tablets Ip 250Mg , Azithromycin Tab Ip 500 Mg , Benzathine Benzylpenicillin Inj Ip 12 Lac Units , Benzathine Benzylpenicillin Inj Ip 6 Lac Units , Cefixime Tab Ip 100 Mg/Cefixime Dispersible Tab Ip 100 Mg , Cefixime Tab Ip 200 Mg , Cefoperazone And Sulbactum For Inj (Cefoperazone Sodium Eq.To Cefoperazone 1Gm And Sulbactum Sodium Eq. To Sulbactum 0.5Gm)(Im/Iv Use) , Cefotaxime Injection Ip 1 G , Cefotaxime Inj Ip 250 Mg , Ceftazidime Inj Ip 1G , Ceftazidime Inj Ip 250 Mg , Ceftazidime Inj Ip 500 Mg , Ceftriaxone Inj Ip 1G /Vial , Ceftriaxone Inj Ip 250 Mg/Vial , Ceftriaxone Inj Ip 500Mg/Vial , Cephalexin Cap Ip 250 Mg , Cephalexin Cap Ip 500 Mg , Chloroquine Phosphate Inj Ip 40 Mg/ Ml , Chloroquine Phosphate Tab. Ip 250Mg Eq To 155 Mg Of Chloroquine Base Film Coated , Chloroquine Phosphate Suspension Ip 50 Mg/5Ml , Ciprofloxacin Injection Ip 200Mg/100Ml , Ciprofloxacin Tablets Ip 250 Mg Film Coated , Ciprofloxacin Tablet Ip 500 Mg Film Coated , Clotrimazole Cream Ip 2% W/W , Clotrimazole Vaginal Tab Ip 500Mg , Co-Trimoxazole Oral Suspension Ip Each 5 Ml Contains Trimethoprim 40 Mg And Sulphamethoxazole 200 Mg , Co-Trimoxazole Tablets Ip Trimethoprim 40 Mg And Sulphamethoxazole 200 Mg , Diethylcarbamazine Tab Ip 100 Mg , Doxycycline Cap Ip 100 Mg , Fluconazole Tablets Ip 150Mg , Gentamycin Injection Ip 80Mg/2Ml (Im/ Iv Use) , Griseofulvin Tab Ip 125 Mg , Itraconazole Cap 100 Mg , Meropenem Inj Ip 500 Mg , Metronidazole Inj Ip 500 Mg/100Ml , Metronidazole Benzoate Oral Suspension Ip 100 Mg Of Base/5Ml , Metronidazole Tablets Ip 200 Mg (Film Coated) , Metronidazole Tablets Ip 400 Mg (Film Coated) , Norfloxacin Tab Ip 400Mg Film Coated , Ofloxacin Tab Ip 200 Mg , Primaquine Tab Ip 2.5 Mg , Primaquine Tab Ip 7.5 Mg , Quinine Dihydrochloride Inj Ip 300 Mg/Ml , Quinine Sulphate Tablets Ip 300 Mg (Film Coated) , Ampicillin Cap Ip 500Mg , Nitrofurantoin Tab Ip 100Mg , Cloxacillin Sodium Inj Ip 500Mg , Cephalexin Oral Suspension Ip (Cephalexin Dry Syrup Ip) 125Mg/ 5 Ml , Ofloxacin Oral Suspension Ip 50Mg/ 5Ml , Tinidazole Tab Ip 300 Mg (Film Coated) , Tinidazole Tab Ip 500 Mg (Film Coated) , Piperacillin + Tazobactum For Injection Ip 4Gm+500Mg , Amoxycillin Oral Suspension Ip (Dry Syrup) 125 Mg/5Ml , Cefpodoxime Dispersible Tab 50 Mg , Cephalexin Tablets 125 Mg (Dispersible Tablets) , Meropenem Inj. Ip 1Gm , Acyclovir Intravenous Infusion Ip 250Mg , Acyclovir Intravenous Infusion Ip 500Mg , Amikacin Inj Ip 250 Mg , Amoxicillin And Potassium Clavulanic Ip Inj 600Mg , Amoxicillin And Potassium Clavulanate Inj Ip 1.2Gm , Amoxycillin And Potassium Clavunate Oral Suspension Ip 200 Mg +28.5 Mg/5 Ml (30Ml Bottle) , Artesunate Injection 60 Mg (I.M. I.V.Use) Each Combo Pack Contains Artesunate Injection 60 Mgvial, Sodium Bicarbonate Injection Ip 5 O/O W/V (1Ml Ampoule),Sodium Chloride Injection Ip 0.9O/O W/V (5Ml Ampoule) , Aztreonam Injection Usp 500 Mg , Cefepime Injection Ip 500 Mg , Cefixime Oral Suspension Ip 25Mg/Ml (Paediatric Drops) , Cefuroxime Axetil Tab Ip 250 Mg , Clindamycin Capsule Ip 150Mg , Clindamycin Capsule Ip 300 Mg , Levofloxacin Tablets Ip 250 Mg , Linezolid Tablets Ip 600 Mg , Linezolid Inj 200Mg/100Ml , Mefloquine Tablets Ip 250 Mg , Ofloxacin And Ornidazole Tablets Ofloxacin 200 Mg And Ornidazole 500 Mg , Ofloxacin Infusion Ip 200Mg / 100 Ml(In Nacl Inj) , Vancomycin For Intravenous Infusion Ip 500 Mg , Vancomycin For Intravenous Infusion Ip 1 Gm , Artemether And Leumefantrine Tablet (80 Mg And 480 Mg) , Co-Trimoxazole Tablet Ip (Trimethoprim 160Mg+Sulphamethoxazole 800Mg) , Aztreonam Injection 1Gm , Framycetin Sulphate Cream 1 O/O 30Gm Pack , Framycetin Sulphate Cream 1 O/O 100 Gm Pack , Artemether And Leumefantrine Tablet (40 Mg And 240 Mg) , Amoxycillin Tablet 250 Mg+Calvulanic Acid 125 Mg Ip Each Film Coated Tab Conatin Amoxycillin Trihydrate Ip 250 Mg & Potassium Clavulanate Ip 125 Mg , Piperacillin Injection 2 Gm + Tazobactom 250Mg Ip , Ceftriaxone 1 Gm + Tazobactum 125 Mg Injection , Cefadroxil Dispersible Tablet 250 Mg(Each Uncoated Dispersible Tablet Contain Cefadroxil Equivalent To Anhydrous Cefadroxil 250 Mg) , Cefadroxil Tablet 500 Mg , Ofloxacin Oral Suspension Ip (Each 5Ml Contains Ofloxacin Ip 100 Mg) 30 Ml Size , Levofloxacin Tablet Ip 500 Mg (Each Film Coated Tablet Contains Levofloxacin Hemihydrate Ip 500 Mg) , Faropenem Tablet Sodium 200 Mg (Each Film Tablet Contains Faropenem Sodium Equivalent To Faropenem Sodium 200 Mg) , Clindamycin Phosphate Injection Ip 300 Mg , Imipenem + Cilastatin Injection 500Mg/500Mg Ip Powder For Solution , Polymixin Sulphate B Injection Usp 5 Lac I.U. , Meropenem Injection Ip 250 Mg , Colistimethate Injection Ip 1M Iu Powder For Solution , Voriconazole Injection 200Mg/Vial , Terbinafine Hydrochloride Tablet 250 Mg , Valganciclovir Tablet 450 Mg , Entecavir Tablet Ip 0.5 Mg (Each Film Coated Tablet Conatins Entecavir Ip 0.5 Mg) , Ganciclovir Sodium Injection 500Mg (Lyophilized Powder For Reconstitution) , Azathioprine Tab Ip 50 Mg , Bleomycin Injection Ip 15Mg (Bleomycin Sulphate Injection 15 Units) , Chlorambucil Tab Ip 5 Mg , Cisplatin Inj Ip 50 Mg/ 50 Ml , Cyclophosphamide Inj Ip 200 Mg , Cyclophosphamide Inj Ip 500 Mg , Cytarabine Injection Bp 500Mg , Danazol Cap Ip 50 Mg , Daunorubicin Inj Ip 20 Mg , Doxorubicin Inj Ip 50 Mg/ 25 Ml , Etoposide Inj Ip 100 Mg , Fluorouracil Inj Ip 250 Mg/ 5Ml , L-Asparaginase Inj 10000 Iu , Leucovorin Calcium Inj Ip / Calcium Folinate Inj Ip 10 Mg /Ml , Melphalan Tab Ip 5 Mg , Mercaptopurine Tab Ip 50 Mg , Methotrexate Inj Ip 50 Mg/2 Ml , Methotrexate Tab Ip 2.5 Mg , Paclitaxel Inj Ip 260 Mg , Paclitaxel Inj Ip 100 Mg , Tamoxifen Tab Ip 10 Mg , Vinblastine Inj Ip 10Mg/ 10Ml , Vincristine Inj Ip 1Mg(Vial)/Vincristin Injection Usp 1Mg/Ml (Amp) , Alpha Interferon Injection Interferon Alpha 2 Concentrated Solution Ip 3 Million Unit , Carboplatin Injection Ip 150 Mg , Carboplatin Injection Ip 450 Mg , Cisplatin Inj Ip 10 Mg/10 Ml , Dacarbazine Injection 500 Mg Ip , Filgrastim Injection Ip (Granulocyte Colony Stimulating Factor) (Sc/Iv Use) 300 Mcg , Gemcitabine For Injection 200 Mg , Gemcitabine For Injection Ip 1Gm , Ifosfamide Injection Ip 1Gm , Imatinib Tab Ip 400Mg , Methotrexate Tablets Ip 10 Mg , Oxaliplatin Injection Usp 50 Mg , Cyclosporin Capsule Ip 50 Mg , Bendamustine Injection 100 Mg , Capecitabine Tablet Ip 500 Mg (Each Film Coated Tablet Contains Capecitabine Ip 500 Mg) , Letrozole Tablet Ip 2.5 Mg (Each Film Coated Tablet Contains Letrozole Ip 2.5 Mg) , Temozolomide Capsule Ip 100 Mg (Each Hard Gelatin Capsule Contains Temozolomide Ip 100Mg) , Bortezomib Injection 2Mg , Abiraterone Acetate Tablet Ip 250 Mg (Each Uncoated Tablet Contains Abiraterone Acetate Ip 250 Mg) , Thalidomide Capsule Usp 100 Mg (Each Hard Gelatin Capsule Contains Thalidomide Usp 100 Mg) , Bevacizumab Injection 400 Mg , Bevacizumab Injection 100 Mg , Cyclophosphamide Tablet Ip 50 Mg (Each Sugar Coated Tablet Contains Cyclophosphamide Ip 53.5 Mg Equivalent To Anhydrous Cyclophosphamide 50 Mg) , Gefitinib Tablet Ip 250 Mg (Each Film Coated Tablet Contains Gefitinib Ip 250 Mg) , Mycophenolate Mofetil Capsule/Tablets Ip 250 Mg (Each Capsule/Tablets Conatin Mycophenolate Mofetil Ip 250 Mg) , Tacrolimus Capsule Ip 0.5 Mg (Each Hard Gealtin Capsule Tacrolimus Ip 0.5 Mg) , Mycophenolate Sodium Tablet 360 Mg (Each Enteric Coated Tablet Conatin Mycophenolate Sodium 360 Mg) , Bicalutamide Tablet Ip 50 Mg (Each Film Tablet Contains Bicalutamide Ip 50 Mg) , 6 Thioguanine Tablet Usp 40 Mg (Each Uncoated Tablet Contains 6 Thioguanine Usp 40 Mg) , Zoledronic Acid Injection Ip 4Mg Vial , Dasatinib Tab 100 Mg , Levodopa And Carbidopa Tablets Ip Levodopa 100 Mg + Carbidopa 10 Mg , Levodopa And Carbidopa Tab 250 Mg+ 25 Mg , Trihexyphenidyl Hcl Tab Ip 2 Mg , Bromocriptine Tablets Ip 2.5 Mg , Acenocoumarol Tab Ip/ Nicoumalone Tab Ip 2 Mg , Deferasirox Tab 100 Mg , Deferasirox Tab 500 Mg , Deferiprone Cap 250 Mg , Deferiprone Cap 500 Mg , Desferrioxamine Injection Ip 500 Mg / Vial (For I.M. Inj And I.V S.C. Infusion) , Dried Human Anti Haemophlic Fraction Ip (Dried Factor Viii Fraction Ip) 250 Iu/ Vial (Iv Use) , Enoxaparin Sodium Inj Ip 60 Mg , Ethamsylate Inj 250 Mg/ 2Ml (Im/Iv) , Heparin Sodium Inj Ip 5000 Iu/Ml (Im/Iv Use) , Human Albumin Solution Ip 20% , Rh-Erythropoetin Inj Ip 10000 Iu , Rh-Erythropoetin Inj Ip 2000Iu , Rh-Erythropoetin Inj 4000 Iu , Vitamin K Injection Each Ml Contains Menadione Sodium Bisulphite 10Mg Equivalent To 5.2 Mg Of Menadione. (Aqueous Solution) , Polygeline 3.5% Solution With Electrolytes For I.V. Infusion , Factor Ix Concentrate (Purified) Ip 500-600 I.U.(Human Coagulation Factor Ix) , Anti Inhibitor Coagulation Complex (Human Plasma Protein With A Factor Viii Inhibitor Bypassing Activity Of 500 I.U. Per Vial With 10 Ml Solvent) , Hydroxyethyl Starch (130/0.4) 6 O/O W/V With Sodium Chloride 0.9 O/O W/V Intravenous Infusion / Balanced Electrolyte Solution Of Sodium Chloride, Sodium Acetate, Potassium Chloride, Magnesium Chloride Intravenous Infusion , Tranexamic Acid Tablets Ip 500 Mg , Warfarin Sodium. Tab Ip 5Mg , Vitamin K-1 (Phytomenadione) Ip 1Mg/0.5Ml Injection (Detail In Rc) , Dried Factor Viii Fraction Ip (Iv Use) 500 Iu/Vial , Dried Factor Viii Fraction Ip (Iv Use) 1000 Iu/Vial , Recombinant Coagulation Factor Viia 1Mg , Recombinant Coagulation Factor Viia 2Mg , Ethamsylate Tablet 500 Mg (Each Uncoated Coated Tablet Contains Ethamsylate Bp 500 Mg) , Feracrylum 1% W/V Sterile Solution 100 Ml , Tranexamic Acid Injection Ip 100Mg/Ml 5Ml Size , Recombinant F Ix 500 Iu With Diluent , 3Rd Generation Recombinant F Viii 250 Iu With Diluent , 3Rd Generation Recombinant F Viii 1000 Iu With Diluent , Amiodarone Tab Ip 100 Mg , Amiodarone Tab Ip 200 Mg , Amiodarone Hydrochloride Inj 50 Mg/Ml , Amlodipine Tab Ip 2.5 Mg , Amlodipine Tablets Ip 5 Mg , Atenolol Tab Ip 50 Mg , Atorvastatin Tab Ip 10Mg , Clopidogrel Tab Ip 75 Mg , Digoxin Inj Ip 0.25 Mg/Ml , Digoxin Tab Ip 0.25 Mg. , Diltiazem Tabs Ip 30 Mg Film Coated , Dobutamine Inj Ip 50Mg/Ml/250Mg (Vial/)Dobutamine Inj Ip 250 Mg/5Ml(Amp) , Dopamine Hydrochloride Inj Ip 40 Mg/Ml , Enalapril Maleate Tab Ip 5Mg , Enalapril Maleate Tab Ip 2.5Mg , Isosorbide Dinitrate Tab Ip 5 Mg , Isosorbide Mononitrate Tabs Ip 20 Mg , Lisinopril Tab Ip 5 Mg , Losartan Tab Ip 50 Mg , Magnesium Sulphate Inj. Ip 500Mg/Ml (50%W/V) , Methyldopa Tab Ip 250Mg Film Coated , Nifedipine Cap Ip 5Mg , Nifedipine Tablets Ip 10 Mg (Sustained Release) , Nitroglycerin Inj 5 Mg/ Ml , Propranolol Tab Ip 40 Mg , Streptokinase Injection 15 Lac Units Ip , Verapamil Tab Ip 40 Mg Film Coated , Labetalol Tab Ip 100Mg , Labetalol Hcl Inj Ip 20Mg/4Ml , Aspirin Delayed Release Tablet / Aspirin Gastroresistant Tab Ip (Each Enteric Coated Tablet Contains Acetyl Salicylic Acid 75 Mg) , Amlodipine And Enalapril Maleate Tablets (Amlodipine Besilate Equivalent To Amlodipine 5 Mg, Enalapril Maleate 5 Mg) , Losartan Potassium And Amlodipine Tablets Ip (Losartan Potassium 50 Mg, Amlodipine Besilate Eq To Amlopdipine 5Mg) , Losartan Potassium And Hydrochlorothiazide Tablets Ip(Losartan Potassium 50 Mg, Hydochlorothiazide 12.5 Mg) , Amlodipine And Lisinopril Tablets Amlodipine Besilate Equivalent To Amlodipine 5 Mg, Lisinopril Eq To Lisinopril (Anhydrous) 5 Mg , Amlodipine And Atenolol Tablet (Amlodipine Besilate Equivalent To Amlodipine 5Mg,Atenolol 50Mg) , Atenolol Tab Ip 25 Mg , Enalapril Maleate Tablets Ip 10 Mg , Lisinopril Tablets Ip 10 Mg , Lisinopril Tab Ip 2.5 Mg , Losartan Tab Ip 25 Mg , Adenosine Injection Ip 6 Mg/2Ml , Atorvastatin Tablets Ip 40 Mg , Clopidogrel And Aspirin Tables, Clopidogrel 75 Mg And Aspirin 75 Mg , Fenofibrate Capsules/ Tab Ip 200 Mg , Isoprenaline Injection Ip 2Mg / Ml , Metoprolol Tablets Ip 25 Mg , Metoprolol Succinate Extended Release Tablets Ip 50 Mg , Noradrenaline Injection Ip 2 Mg/Ml , Prazosin Tablets (Extended Release) 2.5 Mg , Telmisartan Tablets Ip 40 Mg , Urokinase Injection 5 Lac Unit (Lyophilized) , Ramipril Tablets Ip 2.5 Mg , Glyceryl Trinitrate Tablets 2.6 Mg Controlled Release Tablets , Clonidine Hydrochloride Tablet Ip 0.1 Mg (Each Tablet Contains Clonidine Hydrochloride Ip 0.1 Mg) , Sotalol Hydrochloride Tablet Usp/Bp 40Mg (Each Film Coated Tablet Contains Sotalol Hydrochloride Usp/Bp 40Mg) , Esmolol Hydrochloride Injection 10Mg/Ml 10Ml Size , Sodium Nitroprusside Injection 25Mg/Ml 2Ml Size , Carvedilol Tablet 3.125 Mg , Rosuvastatin Tablet Ip 20 Mg (Each Film Coated Tablet Contains Rosuvastatin Calcium Ip Equivalent To Rosuvastatin 20 Mg) , Rosuvastatin Tablet 10 Mg , Sacubitril 24 Mg And Valsartan 26 Mg Tablet , Chlorhexidine Mouthwash Ip 0.2 O/O , Dental Gel Choline Salicylate 8.7 O/O, Benzalkonium Chloride 0.01 O/O, Lignocaine Hcl 2 O/O (Flavoured Gel Base) , Tooth Gel Sodium Monofluorophosphate 0.7 O/O And Potassium Nitrate 5 O/O (In Flavoured Base) , Gum Paint Containing Tannic Acid 2%, Cetrimide 0.1%, Zinc Chloride 1% , Metronidazole 1% And Chlorhexidine Gluconade 0.25% Gel , Compound Benzoic Acid Ointment Ip Benzoic Acid 6 O/O + Salicylic Acid 3 O/O , Acyclovir Cream 5% , Cetrimide Cream Ip 0.50 O/O , Fusidic Acid Cream Ip 2% , Glycerin Ip 400 Gm , Liquid Paraffin Ip 400 Ml , Miconazole Nitrate Cream Ip 2% , Povidone Iodine Ointment 5% 15 Gm , Neomycin Bacitracin And Sulphacetamide Powder (Neomycin 5 Mg, Bacitracin 250 Units, Sulphacetamide 60 Mg) , Silver Sulphadiazine Cream Ip 1% 50Gm Tube , Gentian Violet Topical Solution Usp 1O/O , Clotrimazole Mouth Paint (Clotrimazole 1 O/O W/V) , Beclomethasone, Neomycin And Clotrimazole Cream (Beclomethasone Dipropionate 0.025 %, Neomycin Sulphate 0.5 % And Clotrimazole 1 %) , Gamma Benzene Hexachloride Lotion 1%(Lindane Lotion Usp) , Betamethasone Dipropionate Cream Ip 0.05% , Betamethasone Lotion Ip 0.05 O/O , Clindamycin Phosphate Gel Usp 1 O/O , Clobetasol Propionate Cream Ip 0.05 O/O , Glycerin Ip , Ketoconazole Cream Bp 2% , Permethrin Lotion 5% , Permethrin Cream 5% , Tretenoin Cream Usp 0.025% , Coal Tar 6% & Salicylic Acid 3% Ointment , Calamine Lotion Ip 100Ml , Powder Clotrimazole 1% W/W 30 Gm , Terbinafine Cream 1%W/W (10 Gm Tube) , Olopatadine Hydrochloride Ophthalmic Solution 0.1% W/V Ip (E/D) 5Ml Size , Oitment Mupirocin Ip 2% , Anti A Blood Grouping Serum Ip(Anti A Monoclonal Serum) , Anti B Blood Grouping Serum Ip(Anti B Mono Clonal Serum) , Anti D(Rh) Blood Grouping Serum Ip/Anti D Blood Grouping Serum Ip , Diatrizoate Meglumine & Diatrizoate Sodium Inj Usp 60% (Iodine Conc.= 292 Mg/Ml) , Diatrizoate Meglumine And Diat Sod Inj Usp 76%W/V (Iodine = 370 Mg/Ml) , Gadodiamide Inj. 0.5Mml/Ml Vial , Vdrl Antigen (With + Ve And - Ve Control) / Rpr Slide Kit , Iohexol Usp (Solution For Injection) Non Ionic Contrast Medium In Sterile Aquous Solution 300 Mg Iodine/Ml , Iohexol Usp(Solution For Injection) Non Ionic Contrast Medium In Sterile Aqueous Solution 350 Mg Iodine/Ml. , Multistix Test Strip , Povidone Iodine Solution Ip 5 % 500 Ml , Compound Benzoin Tincture Ip , Formaldehyde Solution (34.5 Per. - 38 Per.) , Gluteraldehyde Solution 2% , Hydrogen Peroxide Solution Ip 6 O/O (20 Vol) , Lysol (Cresol With Soap Solution) Ip (Cresol 50 O/O + Soap 50 O/O) , Povidone Iodine Scrub Solution / Cleansing Solution 7.5 O/O W/V Povidone Iodine (Suitable For Hand Wash) , Surgical Spirit Ip (500 Ml) , Chlorhexidine Gluconate Solution 5% 250 Ml , Surgical Spirit Ip (100 Ml) , Povidone Iodine Solution Ip 5% 100Ml Bottle , Povidone Iodine Ointment Usp 250 Gm , Povidone Iodine Solution Ip 10 % , Silver Sulphadiazine Cream Ip 1% 500 Gm Jar , Acetazolamide Tab Ip 250Mg , Frusemide Tab Ip 40 Mg , Furosemide Injection Ip 10Mg/Ml (Im And Iv Use) , Hydrochlorthiazide Tab Ip 12.5 Mg , Mannitol Inj Ip 20% W/V , Spironolactone Tab Ip 25Mg , Torsemide Tab 10 Ip Mg , Hydrochlorthiazide Tab Ip 25Mg , Spironolactone Tablets Ip 50 Mg , Ciprofloxacin 0.3 O/O And Dexamethasone 0.1 O/O Ear Drops Ciprofloxacin And Dexamethasone Otic Suspension Usp/Ciprofloxacin 0.3 O/O And Dexamethasone 0.1 O/O Eye Drops/Ear Drops , Clotrimazole 1 O/O With Beclomethasone Dipropionate 0.025 O/O Ear Drops , Neomycin, Polymixin B And Hydrocortisone Ear Drops Neomycin Sulphate 3400 Iu, Polymixin B Sulphate 10000 Iu, And Hydrocortisone 10 Mg Per Ml Neomycin And Polymixin B Sulfate And Hydrocortisone Otic Solution Usp , Ceruminolytic Drops (Wax Dissolving Ear Drops) Paradichlorobenzene 2 O/O , Benzocaine 2.7 O/O , Chlorbutol 5 O/O, Turpentine Oil 15 O/O , Drotaverine Hydrochloride Inj 40 Mg/2 Ml , Ointment Containing Lidocaine Ip 3 O/O Zinc Oxide Ip 5 O/O , Hydrocortisone Ip 0.25 O/O, Allantoin Ip 0.5 O/O , Antacid Tablets.Formula,Each Chewable Tablet Contains Magnesium Trisilicate 250 Mg, Dried Aluminium Hydroxide Gel 120 Mg, Peppermint Oil , Antacid Liquid,Each 5Ml Contains Dried Aluminium Hydroxide Gel 250 Mg, Magnesium Hydroxide 250Mg, Activated Polydimethyl Siloxane 50Mg , Bisacodyl Tab Ip 5 Mg , Dicyclomine Tab Ip 10 Mg , Dicyclomine Inj Ip 10 Mg /Ml , Dicyclomine Hydrochloride Oral Solution Ip 10Mg /5Ml , Domperidone Suspension Ip 5Mg/5Ml , Domperidone Tab Ip 10 Mg , Hyoscine Butylbromide Inj Ip 20 Mg/ Ml , Loperamide Tab Ip 2 Mg , Metoclopramide Inj Ip 10Mg/2Ml , Metoclopramide Tab Ip 10 Mg , Omeprazole Cap Ip 20 Mg , Ondansetron Inj Ip 2Mg/Ml , Ors Powder Ip , Pentoprazole Inj 40 Mg , Ranitidine Hcl Injection Ip 50Mg/2Ml , Ranitidine Tab Ip 150Mg Film Coated , Sodium Phosphates Enema Bp Each 100Ml Contains Sodium Dihydrogen Phosphate Dihydrate 10 O/O Disodium Hydrogen Phosphate Dodecahydrate 8 O/O , Hyoscine Butyl Bromide Tablets Ip 10Mg , Drotaverine Tab Ip 40 Mg , Ranitidine Tab Ip 300Mg Film Coated , Dicyclomine Hydrochloride And Activated Dimethicone Suspension Each Ml Contains Dicyclomine Hydrochloride 10Mg Activated Dimethicone 40Mg , Dicyclomine And Paracetamol Tablets Dicyclomine Hydrochloride 20 Mg + Paracetamol 325 Mg Tablets , Metoclopramide Hydrochloride Syrup Ip 5 Mg/ 5Ml , Domperidone Oral Drops Ip 10Mg/ Ml (10Ml) , Drotaverine And Mefenamic Acid Tablets Drotaverine 80 Mg And Mefenamic Acid 250 Mg , Lactic Acid Bacillus Tab 60 Million Spores , Lactulose Solution Usp/Bp 10Gm/15Ml Or 3.35 Gm/5Ml , Liquid Paraffin Ip 100 Ml , Ondansetron Orally Disintegrating Tablets Ip 4Mg , Pantoprazole 40Mg And Domperidone 30Mg Sr Cap Ip Pantoprazole As Enteric Coated Pellets And Domperidone As Sr Pellets , Ursodeoxycholic Acid Tablets Ip 300 Mg , Doxylamine Succinate 20 Mg & Pyridoxine Hydrochloride 20 Mg Tablet (Each Enteric Coated Tablet Contains Doxylamine Succinate Usp 20 Mg & Pyridoxine Hydrochloride Ip 20 Mg ) , Probiotic Sachets 1 Gm Size (Each Gram Sachet Contains Saccharomyces Boulardii 250Mg & Lactic Acid Bacillus 150 Million Spores) , Mesalamine Tablet Ip 1.2 Gm Enteric Coated (Each Enteric Coated Prolonged Release Tablet Conatin Mesalamine Ip 1.2 Gm) , Allopurinol Tablets Ip 100 Mg , Hydroxychloroquine Sulphate Tablets Ip 200Mg , Leflunomide Tablets Ip 10Mg(Film Coated) , Leflunomide Tablets Ip 20Mg (Film Coated) , Sulfasalazine Gastroresistant Tablets Ip 500 Mg Ip , Biphasic Isophane Insulin Inj Ip (30 % Soluble Insulin And 70 % Isophane Insulin) Inj. 40 Iu/Ml(R-Dna Origin) , Carbimazole Tabs Ip 5 Mg , Carboprost Tromethamine Injection Ip Each Ml Contains Carboprost 0.25 Mg/Ml , Clomifene Tab Ip 25 Mg , Clomiphene Tab Ip 50 Mg , Conjugated Estrogen Tabs Usp 0.625 Mg. , Dinoprostone Cream/ Gel 0.5 Mg Dinoprostone In Syringe , Ethinyloestradiol Tabs Ip 50 Mcg , Glibenclamide Tab Ip 5 Mg , Gliclazide Tab Ip 40 Mg , Glimepiride Tab Ip 2 Mg , Glimepiride Tab Ip 1Mg , Glipizide Tab Ip 5Mg , Hydroxyprogesterone Inj Ip 250Mg /Ml , Isophane Insulin Inj Ip 40 Iu /Ml , Metformin Tab Ip 500 Mg , Norethisterone Tab Ip 5 Mg , Pioglitazone Tab Ip 15 Mg , Progesterone Inj Ip 200 Mg/ 2Ml , Insulin Injection Ip (Soluble Insulin/Neutral Insulin Injection)40 Iu/Ml(R.Dna Origin) , Thyroxine Sodium Tablets Ip 100Mcg , Metformin Hydrochloride(Sustained Release Tablets Ip 1000 Mg , Glipizide And Metformin Hydrochloride Tablets Usp (Glipizide 5 Mg, Metformin Hydrochloride 500 Mg) , Glibenclamide And Metformin Hydrochloride (Sr) Tablets Glibenclamide 5 Mg, Metformin Hydrochloride 500 Mg (Sustained Release) , Metformin Hcl (Sustained Release) And Glimepiride Tab Metformin Hcl (Sustained Release) 500Mg ,Glimepiride 1Mg , Metformin Hydrochloride (Sustained Release) And Glimepiride Tablets Ip (Metformin Hydrochloride(Sustained Release) 500 Mg, Glimipiride 2Mg) , Glimepiride, Pioglitazone And Metformin Hydrochloride (Sustained Release) Tablets Each Tablet Contains Glimepiride 2Mg, Pioglitazone 15 Mg, Metformin Hydrochloride (Sustained Release) 500 Mg , Gliclazide And Metformin Tablets (Gliclazide 80 Mg And Metformin Hcl 500 Mg) , Glucagon For Injection Usp 1 Mg , Medroxyprogesterone Acetate Tablets Ip 10 Mg , Thyroxine Tablets Ip 50 Mcg , Octreotide Injection 50 Mcg/Ml , Insulin Glargine 3Ml (100Iu/Ml) With 15 Insulin Syringes And Needles/Cartridge 3Ml (100Iu/Ml) With 15 Needles And 1 Pen Per 20 Cartridges , Tenaligliptin Tablet Ip 20Mg , Insulin Glargine 10 Ml Vial (100 Iu/Ml) With 30 Insuline Syringes With Needle , Human Anti D Immunoglobulin Injection 300Mcg (Im Use) , Human Anti D Immunoglobulin 150 Mcg , Human Rabies Immunoglobulin Inj 150 Iu/ Ml , Rabies Vaccine Human (Cell Culture) Ip (Intradermal) 2.5 Iu , Rabies Vaccine Human (Cell Culture) Ip (Intramuscular) 2.5 Iu/ Dose , Snake Venum Anti Serum Ip (Lyophilized)Polyvalent Anti Snake Venum,Serum Enzyme Refined.Contain Purified Equine Globulins.1 Ml Of Serum Neutralizes 0.6 Mg Of Cobra Venum,0.45 Mg Of Common Kraite(Bungaras)Venum(Details In Rc) , Tetanus Immunoglobulin Ip 250 Iu/ Vial , Tetanus Vaccine (Adsorbed) Ip 5 Ml Vial , Rabies Antiserum Ip (Equine) 300 Units Per Ml Contains Equine Anti-Rabies Immunoglobulin Fragments (I.M./Sc Use) , Diphtheria Antitoxin 10000 Iu , Hepatitis B Immunologlobin Injection Ip 200 I.U , Human Immunoglobulin Inj With 12%Igm,12%Iga,76%Igg In Pack Of 10Ml(0.5Gm) , Atracurium Inj 10 Mg/Ml , Glycopyrrolate Inj Ip 0.2 Mg/Ml , Midazolam Inj Ip 1 Mg/Ml , Neostigmine Inj Ip 0.5 Mg/Ml , Succinylcholine Inj. Ip 50 Mg/Ml (Iv Use) , Valethamate Bromide Inj 8Mg / Ml , Vecuronium Bromide For Injection 4Mg (Freeze Dried) , Chlorzoxazone , Diclofenac Sodium & Paracetamol Tablets (Chlorzoxazone 250Mg , Diclofenac Sodium 50Mg Paracetamol 325 Mg) , Neostigmine Injection Ip 2.5Mg/5Ml , Cis Atracurium Besylate Injection 2 Mg/Ml In 5 Ml Vial , Tropicamide Eye Drop Ip 1O/O , Atropine Eye Ointment Ip 1% , Atropine Sulphate Ophthalmic Solution Usp 1% , Chloramphenicol Eye Drops Ip 0.5 0/0 , Ciprofloxacin Eye Drops Ip 0.3 O/O W/V /Ciprofloxacin Eye/Ear Drops Ip 0.3 O/O W/V , Ciprofloxacin Ophthalmic Ointment Usp 0.3% , Hydroxypropylmethyl Cellulose Solution 20 Mg/ Ml , Tobramycin And Dexamethasone Ophthalmic Suspension Usp 0.3 O/O +0.1 O/O , Tobramycin Eye Drops 0.3% , Tobramycin Ophthalmic Ointment Usp 0.3% , Flurbiprofen Sodium Ophthalmic Solution Ip 0.03 O/O W/V , Hyaluronidase Injection Ip Each Vial Contains Hyaluronidase Ip 1500 I.U. , Lidocaine Hcl Topical Solution Usp 4% , Fluconazole Eye/Ear Drops 0.3% , Timolol Eye Drops Ip 0.5 O/O W/V , Homatropine Eye Drops Ip 2% , Travoprost Eye Drops Ip 0.004 O/O , Brimonidine Tartrate & Timolol Maleate Eye Drops 0.15% + 0.5% , Betaxolol Eye Drops 0.5 O/O , Carboxymethylcellulose Eye Drops Ip 0.5% , Acyclovir Eye Ointment Ip 3% W/W 5Gm Size , Eye Drop Moxifloxacin 0.5% W/V Ophthalmic Solution Ip 5Ml Size , Chloramphenicol 1% W/W Eye Ointment Ip, 3Gm Size , Isoxsuprine Inj Ip 5 Mg/Ml , Isoxsuprine Tab Ip 20 Mg , Methylergometrine Inj Ip 0.2 Mg/Ml , Methylergometrine Tab Ip 0.125 Mg , Misoprostol Tab Ip 200 Mcg , Oxytocin Inj Ip 5 Iu/Ml , Mifepristone Tab Ip 200Mg , Natural Micronised Progesteron Soft Gelatin Capsule 200 Mg (Each Soft Gelatin Capsule Contains Progesteron Ip 200 Mg)/Natural Micronised Progesteron Tablet 200 Mg (Each Tablet Contains Progesteron Ip 200 Mg) , Cabergoline Tablet Ip 0.5Mg (Each Uncoated Coated Tablet Contains Cabergoline Ip 0.5Mg) , Human Chorionic Gonadotropin Injection Ip 5000 I.U. , Leurprolide Acetate Depot 3.75 Mg , Leurprolide Acetate Depot 11.25 Mg , Alprazolam Tab Ip 0.25 Mg , Alprazolam Tab Ip 0.5Mg , Amitriptyline Tab Ip 25Mg Film Coated , Chlordiazepoxide Tablets Ip 10Mg , Chlorpromazine Tablets Ip 100 Mg (Coated Tablet) , Chlorpromazine Tablets Ip 50 Mg (Coated Tablets) , Diazepam Inj Ip 10Mg/2Ml (1M/Iv Use) , Diazepam Tab Ip 5 Mg , Escitalopram Tab Ip 10 Mg , Fluoxetine Cap/Tab Ip 20Mg , Haloperidol Inj Ip 5 Mg/Ml , Haloperidol Tab Ip 1.5 Mg , Haloperidol Tab Ip 5 Mg , Imipramine Tab Ip 25 Mg (Coated Tab) , Imipramine Tab Ip 75 Mg (Coated) , Lithium Carbonate Tab Ip 300 Mg , Lorazepam Inj Ip 2 Mg/Ml , Olanzapine Tab Ip 5 Mg , Risperidone Tab 2Mg , Risperidone Tab 1 Mg , Sertraline Tab Ip 50 Mg , Trifluperazine Tab Ip 5 Mg Coated , Quetiapine Tablet Ip 50Mg , Quetiapine Tablet Ip 25Mg , Clonazepam Tablet 0.5 Mg , Levosulpiride Tablet 25 Mg (Each Uncoated Tablet Contains Levosulpiride 25 Mg) , Lorazepam Tablet Ip 2 Mg (Each Uncoated Tablet Contains Lorazepam Ip 2 Mg ) , Zolpidem Tablet 5 Mg , Aminophylline Inj Ip 25 Mg/Ml , Beclomethasone Inhalation Ip 200 Mcg/Dose , Budesonide Nebulizer Suspension 0.25Mg/Ml , Ipratropium Bromide Nebulizer Solution 250 Mcg/ Ml , Salbutamol Tablet Ip 4 Mg , Salbutamol Inhalation 100 Mcg /Dose , Salbutamol Nebuliser Solution Bp 5 Mg/Ml , Salbutamol Tab Ip 2 Mg , Theophylline And Etofylline Injection (Anhydrous Theophylline 50.6Mg + Etofylline 169.4 Mg) , Theophylline And Etofylline Tablets Ip (Theophylline Ip 23Mg + Etofylline Ip 77 Mg) , Theophylline Tablet 400Mg Sustained Release/ Controlled Release (Theophylline Prolonged Released Tablet Ip) , Salbutamol Syrup Ip 2Mg/ 5Ml , Dextromethorphan Hbr Syrup Ip 13.5Mg / 5Ml , Saline Nasal Solution (Drops) (Sodium Chloride 0.65 O/O) , Formoterol Fumerate & Budesonide Powder For Inhalation Ip 6 Mcg + 200 Mcg , Budesonide Powder For Inhalation Ip 200 Mcg , Ipratropium Powder For Inhalation Ip 40 Mcg , Terbutaline Tablets Ip 2.5 Mg , Xylometazoline Nasal Drops Ip 0.1% , Cough Syrup/Expectorant(50) Ml , Acebrophylline Tablet/Capsule 100 Mg , Compound Sodium Lactate Inj. Ip , Dextrose Inj Ip 25% W/V , Dextrose Inj Ip 10% , Dextrose Inj Ip 5% , Multiple Electrolytes And Dextrose Injection Type I Ip (Electrolyte P Injection ) , Multiple Electrolytes And Dextrose Injection Type Iii Ip Electroylte M Injection ( I.V. ) , Potassium Chloride Inj. Ip 0.15 Gm/Ml , Potassium Chloride Oral Solution U.S.P 500Mg/ 5Ml , Sodium Chloride And Dextrose Injection Ip 0.9 O/O + 5 O/O , Sodium Chloride Inj Ip 500 Ml , Sodium Chloride Injection Ip 100 Ml , Ringer Acetate Infusion 500 Ml , Sodium Chloride 0.45% W/V Polypack 500 Ml , Finasteride Tablets Ip 5 Mg , Tamsulosin Hcl Tablets/Capsule 0.4 Mg , Flavoxate Tablets Ip 200 Mg (Coated Tablet) , Savelamer Carbonate Tablet 400 Mg (Each Film Coated Tablet Contains Savelamer Carbonate 400 Mg) , Sodium Bicarbonate Tablet Usp 1 Gm (Each Film Coated Tablet Contains Sodium Bicarbonate Usp 1 Gm) , Levamisol Hydrochloride Tablet Ip 50 Mg (Each Uncoated Tablet Conatin Levamisol Hydrochloride Ip 50 Mg) , Dutasteride Tablet 0.5 Mg , Alkylizer 1.4Gm To 1.53 Gm Per 5 Ml(Disodium Hydrogen Citrate) Syrup/Solution , Betahistine Tab Ip 8 Mg , Betahistine Tab Ip 16 Mg , Cinnarizine Tablets Ip 25 Mg , Cinnarizine Tablet Ip 75 Mg , Ascorbic Acid Tab Ip 500 Mg , Calcium Gluconate Inj Ip 10% (Iv Use) , Ferrous Sulphate With Folic Acid Tab Ip Each Film Coated Tab. Containing Dried Ferrous Sulphate Ip-Equiv 100 Mg Elemental Iron And Folic Acid Ip 0.5 Mg , Ferrous Sulphate With Folic Acid Tab (Paediatric) Ip Each Film Coated Tab. Containing Dried Ferrous Sulphate Ip-Eqivalent To 20Mg Elemental Iron And Folic Acid Ip-100 Mcg , Folic Acid Tab Ip 5 Mg , Multivitamin Drops Each Ml Contains Vit A 3000 Iu, Vit D3 300 Iu, Vit B1 1Mg, Riboflavine Phosphate Sodium 2Mg, D-Panthenol 2.5Mg, Niacinamide 10Mg, Pyridoxine Hcl 1Mg, Cyanocobalamin 1Mcg, Lysine Hcl 10Mg , Multivitamin Tablets Nfi Formula Sugar Coated Vit A 2500 Iu Vit B1-2Mg Vit-B6-0.5Mg Vit-C-50Mg Calcium Pantothenate-1Mg Vit-D3-200Iu Vit-B2-2 Mg Niacinamide-25Mg Folic Acid-0.2 Mg , Vitamin B Complex Inj Nfi , Vitamin B Complex Tablet Nfi (Prophylactic) B1 2Mg B2-2Mg B6- 0.5Mg Niacinamide 25Mg Calcium Pantothenate 1Mg (With Appropriate Overages) , Vitamin A Paediatric Oral Solution Ip(Vitamin A Concentrate Oil Ip)Each Ml Contains Vitamin A 100000 Iu , Calcium And Vitamin D3 Suspension (Each 5 Ml Contains Calcium Carbonate Equivalent To Elemental Calcium 250 Mg, Vitamin D3 125 Iu ) , Iron And Folic Acid Suspension. Each 5Ml Contains Ferrous Fumerate Equivalent To Elemental Iron 100Mg, Folic Acid 500 Mcg , Zinc Sulphate Dispersible Tablets Ip Elemental Zinc 10 Mg , Iron Sucrose Injection Usp/Bp 20Mg/Ml (For Iv Use) Each Ml Contains Ferric Hydroxide In Complex With Sucrose Equiv. To Elemental Iron 20 Mg , Calcium With Vitamin D Tablets Usp /Calcium And Colecalciferol Tablets Bp/Calcium And Vitamin D3 Tablets Ip(Elemental Calcium 500 Mg, Vitamin D3-250 Iu) (Non-Chewable) , Cholecalciferol Granules 60,000 Iu /Gm , Mecobalamin Inj 500 Mcg/Ml , Pyridoxine Tablet Ip 40Mg , Thiamine Tablets Ip 100 Mg , Calcitriol Capsules Ip 0.25 Mcg , Methyl Cobalmine Tablet 500Mcg , Methyl Cobalmine Tablet 1500Mcg , Vitamin D3 Oral Solution 60000 Iu , Ferric Carboxymaltose Injection 50 Mg/Ml 10 Ml Size , Multi Vitamin Syrup , Flunarizine Tab 5 Mg , Black Disinfectant Fluid (Phenyl) As Per Schedule O Grade Iii , Conc Haemodialysis Fluid B.P Acetate Concentrate 10 Litre Can , Peritonial Dialysis Solution Ip , Sodium Bicarbonate Inj Ip 7.5% W/V , Water For Inj Ip , Alendronate Sodium Tablets Usp / Bp 35 Mg , Mannitol With Glycerin Injection 10 O/O + 10 O/O W/V (For Intravenous Infusion) , Normal Human Intravenous Immunoglobulin 5G/100Ml , Pregabalin Cap Ip 75 Mg , Surfactant For Intratrecheal Instillation (Natural Bovine Lung Surfactant) , Concentrated Solution For Hameodialysis Bp Sodium Hydrogen Carbonate Concentrate In 10 Litre Cans , Intravenous Fat Emulsion 20% W/V 250Ml , Pyridostigmine Tablet Ip 60 Mg (Each Tablet Contains Pyridostigmine Ip 60 Mg ) , Caffeine Citrate Usp Injection 20Mg/Ml (Equivalent To 10 Mg Caffeine Base/Ml) 3Ml Size , Amino Acid 10% Injection 100Ml Size , Vitamin E Soft Gelatin Capsule 400 Mg , Inj Poractant Alpha 80 Mg/Ml In Pack Of 1.5 Ml (Detail In Rc) , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(3/8 Cir Rb Needle 40 Mm Length 76 Cm) Size -1/0 , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(1/2 Cir Rb Needle 20 Mm Length 76 Cm) Size -3/0 , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(1/2 Cir Rb Needle 30 Mm Length 76 Cm) Size -2/0 , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(1/2 Cir Rb Needle 30 Mm Length 76 Cm) Size -1/0 , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(1/2 Cir Rb Needle 40Mm Length 76 Cm) Size -1/0 , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(3/8 Cir Rb Needle 30 Mm Length 76 Cm) Size-2/0 , Absorbable Surgical Suture (Sterile Catgut) Bp/Usp Needled Suture Chromic(1/2 Cir Rb Needle 45 Mm Length 100 Cm) Size-1 , Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic Size-3/0 (3/8 Cir Rcutting Needle 26Mm, Length 76 Cm) , Absorbable Surgical Suture (Synthetic) Sterilised Needled(Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)Size - 3/0 1/2Cir Rb Needle 20Mm Length 70 Cm , Absorbable Surgical Suture (Synthetic) Sterilised Needled (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)Size-2/0 1/2 Cir Rb Needle 30Mm Length 90 Cm , Absorbable Surgical Suture (Synthetic) Sterilised Needled(Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)1/2 Cir Rb Needle Size-1/0 30Mm Length 90 Cm , Absorbable Surgical Suture (Synthetic)Sterilised Needled(Braided)Coated Polyglactin/Polyglycolic Acid/Poly(Glycolide-Co-L-Lactide)Size 1 1/2 Cir Tapercut Needle (Heavy) 40Mm Length 90 Cm , Absorbable Surgical Suture (Synthetic) Sterilised Needled(Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)Size-1 1/2 Cir Rb Needle40mm Length 90 Cm , Absorbable Surgical Suture(Synthetic)Sterilised Needled(Braided)Coated Polyglactin/Polyglycolic Acid/Poly(Glycolide-Co-L-Lactide)Size-3/0(1/2 Cir Conventional 25Mm Length 90 Cm)Undyed , Absorbable Surgical Suture (Synthetic) Sterilised Needled(Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)Size-4/0 (1/2 Cir Rb Needle 20Mm Length 70 Cm) , Absorbable Surgical Suture (Synthetic) Sterilised Needled (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)Size-2/0 1/2 Cir Rb Needle 40Mm L 90Cm , Absorbable Surgical Suture (Synthetic) Sterilised Needled(Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-Co-L-Lactide)Size-1/0(1/2 Cir Rb Needle 40Mm Length 90 Cm) , Absorbable Surgical Suture (Synthetic) Sterilised Needled(Braided) Coated Polyglactin/Polyglycolic Acid/Poly(Glycolide-Co-L-Lactide)Size 3/0 3/8 Circle Cutting Needle 22Mm Length 45 Cm , Absorbable Surgical Suture(Synthetic)Sterilised Needled(Braided)Coated Polyglactin/Polyglycolic Acid/Poly(Glycolide-Co-L-Lactide)Size-4/0 3/8 Circle Cutting 16Mm Needle,Suture Length 70Cm , Chromic Catgut Suture(3/8 Cir Rcutting Needle 16 Mm, Suture Length 76 Cm) Size 5/0 (Details In Rc) , Chromic Catgut Suture(3/8 Cir Cutting Needle 8 Mm, Suture Length 35 Cm) Size 6/0 (Details In Rc) , Chromic Catgut Suture(3/8 Cir R Cutting Needle 19 Mm Needle, Suture Length 76 Cm) Size 4/0 (Details In Rc) , Non Absorbable Surgical Suture, Sterilised Needled Black Braided Silk Size 3/0(1/2 Cir Rb Needle 20Mm, Length 76 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Black Braided Silk Size 3/0(3/8Cir Reverse Cutting Needle 26Mm, Length 76 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Black Braided Silk Size 2/0(3/8Cir Reverse Cutting Needle 45Mm, Length 76 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black (Nylon) Size 8/0 (3/8 Cir Micropoint Round Body ,6Mm Length 38 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black (Nylon)Size 3/0 (3/8 Conventional Cutting Needle 16Mm Length 70 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black (Nylon)Size 4/0 (3/8 Conventional Cutting Needle 19Mm Length 60 Cm.) , Non Absorbable Surgical Suture,Sterilised Needled Polyamide Monofilament Black (Nylon)Size 5/0(3/8 Cir Slim Blade Cutting Needle 15Mm Length 70 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black (Nylon)Size 2/0 (3/8 Cir R Cutting Needle 45Mm Length 70 Cm.) , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black (Nylon)Size 1/0 (3/8 Cir R Cutting Needle 45Mm Length 70 Cm.) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5/0(1/2 Cir Rb 13 Mm Needle,Length 75Cm) Double Arm , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue (3/8Cir Rb 16 Mm Needle,Length 90 Cm)Size 6/0 , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue Size 7/0 (3/8Cir Rb Double 8Mm Needle, Length 60 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5/0(3/8Cir Rb 16 Mm Needle, Length 70 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1/0(1/2 Cir Rb Needle 30Mm Length 90 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1(1/2 Cir Rb Heavy Needle 45Mm Length 90 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 5/0(1/2 Cir Rb Double Needle 17Mm Length 70 - 90 Cm)(Detail In Rc) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 4/0 (1/2 Cir Tapercut Double Needle 17Mm Length 70 Cm)(Detail In Rc) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3/0 (1/2 Cir Rb Needle 25Mm, Length 90 Cm) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 2/0 (1/2 Cir Rb Needle 30Mm, Length 90 Cm) , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue Size 3/0 (1/2 Cir Tapercut Needle 17Mm Length 75 Cm) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 2/0(1/2 Cir Tapercut Needle,25 Mm Length 90 Cm) Double Arm , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue Size 6/0(3/8 Cir Conventional Cutting Pc-3Needle 15Mm Length 60Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 6/0(3/8 Cir Rb 13Mm Needle, Length 90 Cm Double Arm , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue Size 4/0(1/2 Cir Rb Needle 16 Mm Length 70 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3/0(3/8 Cir Cutting Needle 25Mm Length 45 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1 (1/2 Cir Rb Heavy 40Mm, Length 90 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 1 (1/2 Cir Reverse Cutting, 45 Mm Needle Length 100 Cm) , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue Size 8/0 (3/8 Cir Rb , 8Mm Double Needle, Suture Length Of 70Cm) , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 4/0 (1/2 Circle Tapercut 13Mm Double Needle 70Cm) , Non Absorbable Surgical Suture,Sterilised Needled Monofilament Polypropylene Blue Size 5/0 (1/2 Circle Cc 13Mm Needle, Suture Length Of 70Cm) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 2/0 (1/2 Circle Tapercut Needle 17Mm Suture Length Of 90Cm) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Monofilament Polypropylene Blue Size 3/0 (1/2 Cir Rb Needle 25Mm, Suture Length Of 75Cm) Double Arm , Non Absorbable Surgical Suture, Sterilised Needled Polybutylate/Silicon Coated Polyster Braided Green/ Blue Size 4/0(1/2 Cir Tapercut ,17 Mm Double Needle, Length 75 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Polybutylate / Silicon Coated Polyster Braided White Size 2/0 (1/2 Cir Tapercut ,17 Mm Double Needle, Length 90 Cm) , Non Absorbable Surgical Suture, Sterilised Needled Polybutylate/Silicon Coated Polyster Braided Green/Blue Size 2/0(1/2 Cir Tapercut ,17 Mm Double Needle, Length 90 Cm)(Detail In Rc) , Non Absorbable Surgical Suture Sterilized Needled Polybutylate/Silicon Coated With Polyster Braided(Green/Blue)Size 2/0 1/2 Circle Taper Cut,17Mm Double Armed Needle,Suture Length Of 90Cm With Pledgets Size 6 X 3 X 1.5Mm , Non Absorbable Surgical Suture Sterilized Needled Polybutylate/Silicon Coated With Polyster Braided(Green/Blue)Size 2-0 1/2 Circle Taper Cut,25Mm Double Armed Needle, Suture Length Of 90Cm With Pledgets Size 6 X 3 X 1.5Mm , Non Absorbable Surgical Suture, Sterilised Needled Coated Polyster Braided, Green/White Or Blue/White Coated Polyster Braided (Green / Blue) With Size 3/0 1/2 Circle Tapercut Double Needle 25Mm,Suture Length 90 Cm , Non Absorbable Surgical Suture, Sterilised Needled Polyamide Monofilament Black (Nylon) Size 10/0 (3/8 Cutting Spatulated Edge Needle, Double Arm Needle 6 Mm, Suture Length 30-42 Cm , B.B Silk Suture (3/8 Cir Rb Needle 20Mm, Length 76 Cm Size 4/0 (Details In Rc) , B.B Silk Suture (3/8 Cir Rb Needle 16Mm, Length 76 Cm Size 5/0 (Details In Rc) , Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyglyconate, Monofilament Sutures (1/2 Circle Oval Rb Needle 26-30Mm Needle, Suture Length Of 70Cm) , Absorbable Surgical Suture Polyglyconate, Monofilament Sutures (1/2 Circle Oval Rb Contrast Needle 20-26Mm,Suture Length 70Cm) , Absorbable Surgical Sutures,Sterilised Needled Polyglecaprone/Polyglyconate,Monofilament Sutures Size 2/0 (1/2 Circle Oval Rb Needle 26Mm Needle,Suture Length Of 70Cm) , Absorbable Surgical Sutures Sterilised Needled Monofilament Polyglecaprone / Polyglyconate,Size 3/0 (1/2 Circle Ovalrb Contrast Needle 26Mm, Suture Length 70Cm) , Absorbable Surgical Sutures Sterilised Needled Monofilamentpolyglecaprone /Polyglyconate Size 4/0 (1/2 Circle Cutting 16Mm Needle,Suture Length 70Cm) , Absorbable Surgical Sutures Sterilised Needled Monofilamentpolyglecaprone /Polyglyconate Size 3/0 (3/8 Circle Cutting 25Mm Needle, Suture Length Of 70Cm) , Absorbable Surgical Suture (Synthetic) Sterilised Needled Suture Monofilament Polydioxanone Violet Size 1 (1/2 Circle Reverse Cutting 50 Mm Length 90Cm) , Absorbable Surgical Suture (Synthetic) Sterilised Needled Suture Monofilament Polydioxanone Violet Size 2/0 (1/2 Circle Rb 31Mm Needle, Length 70Cm) , Absorbable Surgical Suture (Synthetic) Sterilised Needled Suture Monofilament Polydioxanone Violet Size 1/0(1/2 Circle Rb 30Mm Needle,Length 70Cm) , Absorbable Surgical Suture(Synthetic)Antibacterial Coated Sterilised Needled(Braided Coated Polyglactin/Polyglycolic Acid Violet)Size 1 1/2 Circle Ct Round Bodied 40Mm,Gs Needle,Suture Length 90 Cm , Absorbable Surgical Suture(Synthetic)Antibacterial With Sterilised Needled(Braided Coated Polyglactin/Polyglycolic Acid Violet)Size 1/0 1/2 Circle Ct Round Bodied 40Mm,Gs Needle,Suture Length 90 Cm , Absorbable Surgical Suture (Synthetic) Antibacterial With Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet)Size 2/0 1/2 Circle Round Bodied 30Mm, Suture Length 90 Cm , Absorbable Surgical Suture (Synthetic) Antibacterial With Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)Size 1 1/2 Circle Reverse Cutting,Os 40Mm, Suture Length 90 Cm , Absorbable Surgical Suture (Synthetic) Antibacterial With Sterilised Needled Suture (Braided Coated Polyglactin / Polyglycolic Acid Violet)Size 1/0 1/2 Circle Reverse Cutting 36Mm, Os Needle, Suture Length 90 Cm , Absorbable Surgical Suture (Synthetic) Antibacterial With Sterilised Needled Suture(Braided Coated Polyglactin/Polyglycolic Acid Violet)Size 3/0 1/2 Circle Round Bodied 20Mm, Suture Length 70 Cm , Absorbable Surgical Suture (Synthetic)Antibacterial With Sterilised Needled Suture (Braided Coated Polyglactin/ Polyglycolic Acid Violet)Size 3/0 3/8 Circle R Cutting, Ps-1,24Mm, Suture Length 70 Cm , Absorbable Gelatin Sponge 80 X 50X 10Mm(Details In Rc) , Asepto Syringe With Transparent Bulb Sterile, 60 Ml , Blood Administration Set Blood Transfusion Set (Details In Rc) , Gloves Size 6.5 Inches,Powdered (Disposable Sterile Surgical Rubber Gloves)(Details In Rc) , Gloves Size 6.5 Inches,Powder Free (Disposable Sterile Surgical Rubber Gloves)(Details In Rc) , Gloves Size 7 Inches,Powdered (Disposable Sterile Surgical Rubber Gloves)(Details In Rc) , Gloves Size 7 Inches,Powder Free (Disposable Sterile Surgical Rubber Gloves)(Details In Rc) , Gloves Size 7.5 Inches,Powdered (Disposable Sterile Surgical Rubber Gloves)(Details In Rc) , Gloves Size 7 .5Inches,Powder Free (Disposablesterile Surgical Rubber Gloves)(Details In Rc) , Suction Catheter, Sterile.Size: Fg 5 (Details In Rc) , Suction Catheter, Sterile. Size: F G-6 (Details In Rc) , Suction Catheter, Sterile. Size: F G-8 (Details In Rc) , Suction Catheter, Sterile. Size: F G-10 (Details In Rc) , Suction Catheter, Sterile. Size: F G-12 (Details In Rc) , Suction Catheter, Sterile. Size: F G-14 (Details In Rc) , Suction Catheter, Sterile. Size: F G-16 (Details In Rc) , Suction Catheter, Sterile. Size: F G-18 (Details In Rc) , Suction Catheter, Sterile. Size: F G-20 (Details In Rc) , Suction Catheter, Sterile. Size: F G-22 (Details In Rc) , Catheter,Size 8(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Catheter,Size 10(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Catheter,Size 16(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Catheter,Size 18(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Catheter,Size 20(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Catheter,Size 22(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Catheter,Size 24(Foleys Ballon Catheter Sterile,2 Way For Urinary Drainage,Single Use,)Silicon Coated Natural Latex Material(Details In Rc) , Infant Feeding Tube Size 10Fg(Details In Rc) , Infant Feeding Tube Size 8Fg(Details In Rc) , Infant Feeding Tube Size 5Fg(Details In Rc) , Perfusion Set With Airway And Needle,(Adult Use) Sterile Disposable(Details In Rc) , Perfusion Set (Infusion Set) With Airway And Needle (Paediatric Use)Sterile Disposable(Details In Rc) , Infusion Set With Microdrip,(I.V.)Sterile Disposable(Details In Rc) , Insulin Syringe ( 40 Units) With (Fixed) 30 G Needle Shall Conforn To Is 12227 , Sterile Disposable (Single Use) Teflon/Ptfe I.V Cannula With Integrated 3 Way Stop Cock Size 16G (Details In Rc) , Sterile Disposable (Single Useteflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock.) Size 18G (Details In Rc) , Sterile Disposable (Single Use) Teflon/Ptfe I.V. Cannula With Integrated 3 Way Stop Cock.Size 20 G (Details In Rc) , Sterile Disposable (Single Use) Teflon/Ptfe I.V. Cannula With Integrated 3 Way Stop Cock.Size 22G (Details In Rc) , Sterile Disposable (Single Use) Teflon/ Ptfe I.V. Cannula Without Port Size 24G (Details In Rc) , Mucus Extractor Sterile(Details In Rc) , Nasal Oxygen Set, Twin Bore All Sizes Adult (Details In Rc) , Nasal Oxygen Set, Twin Bore All Sizes Paediatrics (Details In Rc) , Paper Adhesive Plaster 1 Inch X 9.0 Mts (With Cutter) Non Woven Adhesive Tape , Paper Adhesive Plaster 2 Inch X 9.0 Mts (With Cutter) Non Woven Adhesive Tape , Paper Adhesive Plaster 3 Inch X 9.0 Mts (With Cutter) Non Woven Adhesive Tape , Plaster Of Paris Bandage 15Cm X 2.7 Mts/Roll , Plaster Of Paris Bandage 10Cm X 2.7Mts , Ryles Tube / Nasogastric Tube Size: 10(Details In Rc) , Ryles Tube / Nasogastric Tube Size: 12(Details In Rc) , Ryles Tube / Nasogastric Tube Size:14 (Details In Rc) , Ryles Tube / Nasogastric Tube Size: 16 (Details In Rc) , Ryles Tube / Nasogastric Tube Size: 18 (Details In Rc) , Scalp Vein Set (Disposable) Size 18G (Details In Rc) , Scalp Vein Set (Disposable) Size 20G (Details In Rc) , Scalp Vein Set (Disposable) Size 22G (Details In Rc) , Scalp Vein Set (Disposable) Size 24 G (Details In Rc) , Syringe 2 Ml Hypodermic With Needle Attached 24G,Sterile,Single Use Disposable(Details In Rc) , Syringe 5 Ml Hypodermic With Needle Attached 24G,Sterile,Single Use Disposable(Details In Rc) , Syringe 10 Ml Hypodermic With Needle Attached 22G,Sterile,Single Use Disposable(Details In Rc) , Syringe 20 Ml Hypodermic With Needle Attached 22G,Sterile,Single Use Disposable(Details In Rc) , Surgical Blade Sterile, Size 11(Details In Rc) , Surgical Blade Sterile, Size 15(Details In Rc) , Surgical Blade Sterile, Size 22(Details In Rc) , Sterile Disposable Spinal Needle For Single Use. 22G X 3 1/2 Inch (Details In Rc) , Sterile Disposable Spinal Needle For Single Use. 25G X 3 1/2 Inch (Details In Rc) , Urine Collecting Bag, Disposable 2000 Ml(Details In Rc) , Double J Stent, Sterile, Both Ends Open - Size 4F, Length 16 Cm , Double J Stent, Sterile, Both Ends Open, Size 5F, Length 20 Cm , Double J Stent, Sterile, One End Closed - Size 4F, Length 16 Cm , Double J Stent, Sterile, One End Closed, Size 5F, Length 20 Cm , Endotracheal Tube, Plain - Size 2.5 (Details In Rc) , Endotracheal Tube, Plain - Size 3 (Details In Rc) , Endotracheal Tube, Plain - Size 3.5 (Details In Rc) , Endotracheal Tube, Plain - Size 4 (Details In Rc) , Endotracheal Tube, Plain - Size 4.5 (Details In Rc) , Endotracheal Tube, Plain - Size 5 (Details In Rc) , Endotracheal Tube, Plain - Size 5.5 (Details In Rc) , Endotracheal Tube, Plain - Size 6 (Details In Rc) , Endotracheal Tube, Plain -Size 6.5 (Details In Rc) , Endotracheal Tube, Plain - Size 7 (Details In Rc) , Endotracheal Tube, Plain - Size 7.5 (Details In Rc) , Endotracheal Tube, Plain - Size 8 (Details In Rc) , Endotracheal Tube, Plain - Size 8.5 (Details In Rc) , Endotracheal Tube, Cuffed - Size 4 (Details In Rc) , Endotracheal Tube, Cuff - Size 4.5 (Details In Rc) , Endotracheal Tube, Cuff - Size 5 Details In Rc , Endotracheal Tube, Cuff - Size 6 (Details In Rc) , Endotracheal Tube, Cuff- Size 6.5 (Details In Rc) , Endotracheal Tube, Cuff - Size 7 (Details In Rc) , Endotracheal Tube, Cuff - Size 7.5 (Details In Rc) , Endotracheal Tube, Cuff - Size 8 (Details In Rc) , Endotracheal Tube, Cuff - Size 8.5 (Details In Rc) , Endotracheal Tube, Cuff - Size 9 (Details In Rc) , Tracheostomy Tube, Plain - All Sizes(Details In Rc) , Tracheostomy Tube (Pvc), Cuffed - All Sizes(Details In Rc) , Abdominal Drain Kit (With Collection Bag 2000 Ml Size 24 (Details In Rc) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) Size 28 (Details In Rc) , Abdominal Drain Kit,Sterile,Having Drainage Cather And Collection Bag(2000) Ml Size 32 (Details In Rc) , Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.6Cm X 15Cm Or 7.5Cm X 15Cm , Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 Cm X 15 Cm , Sterilized Umbilical Cotton Tape Width 3 Mm, Length 75 Cm(Details In Rc) , Bone Wax Sterilised , Skin Graft Knife Blade (Sterile)(Details In Rc) , K Wire, Length 375 Mm; 1Mm(Details In Rc) , K Wire, Length 375 Mm; 1.6Mm(Details In Rc) , K Wire, Length 375 Mm; 1.8Mm(Details In Rc) , Face Mask, Disposable(Details In Rc) , Surgical Cap Disposable (For Surgeons)(Details In Rc) , Surgical Cap, Disposable (For Nurses) (Details In Rc)(Details In Rc) , Foldable Intra Ocular Lense With Injector (Details In Rc) 11 To 17.5 , Foldable Intra Ocular Lense With Injector (Details In Rc) 18 To 24 , Foldable Intra Ocular Lense With Injector (Details In Rc) 24.5 To 28.5 , Standard Pama Intra Ocular Lenses (Details In Rc) 11 To 17.5 , Standard Pama Intra Ocular Lenses (Details In Rc) 18 To 24 , Standard Pama Intra Ocular Lenses (Details In Rc) 24.5 To 28.5 , Disposable Sterile Surgical Rubber Gloves Size 8 Inches,Powdered , Disposable Sterile Surgical Rubber Gloves Size 8 Inches,Powder Free , Rubber Examination Gloves, Non-Sterile, Extra Small(Details In Rc) , Rubber Examination Gloves,Size Small (Details In Rc) , Rubber Examination Gloves,Size Medium (Details In Rc) , Rubber Examination Gloves Made Of Natural Rubber Latex, Non-Sterile, Size Large (Details In Rc) , Pressure Monitoring Line / High Pressure Extension Line (Details In Rc) , Urine Collecting Bag For New Born /Paediatric Urine Collection Bag, Capacity 100Ml (Details In Rc) , Umbilical Catheter For New Born, All Sizes -(Details In Rc) , Umbilical Cord Clamp (Details In Rc) , Absorbable Oxidized Regenerated Cellulose Netsize 2 X 3 Topical Absorbable Haemostatic Bactericidal Property(Details In Rc) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) Size Of Bellow 800 Ml, Catheter Size 16 (Details In Rc) , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) Size Of Bellow 800 Ml, Catheter Size 18 (Details In Rc) , Bone Cement , Sanitary Napkin Beltless(Details In Rc) , Sanitary Pads Belt Type(Details In Rc) , Sanitary Napkin Beltless With Wings (Details In Rc) , Sanitary Napkin Beltless With Wings (Udan Yojna) , Oxygen Mask (Adult) , Oxygen Mask (Pediatric) , Foleys Catheter No. 14 (Detail In Rc) , Nelaton Catheter Size 14 Fg(Detail In Rc) , Ecg Electrode (Detail In Rc) , Surgical Blade Sterile, Size 23 Single Peel Package In Metal Foil As Per Is 3319 (Detail In Rc) , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 50 Ml (Detail In Rc) , Urethral Catheter 90 (Fg-14) Made Up Of Medical Grade Pvc (Detail In Rc) , Urethral Catheter 91 (Fg-10), Made Up Of Medical Grade Pvc (Detail In Rc) , Vaccum Suction Set, 2.5 Meter Length (Detail In Rc) , Epidural Minipack 18G, 80Mm-90Mm, Metal Stylet For Single Use Only, Sterile (Detail In Rc) , Vascular Catheter 16G/5Fr, Double Lumen Length 40Cm , Vascular Catheter With Metal Guide Wire, 4Fr Single Lumen, Distalvalve, Saline Flush Only Size 45Cm Or More , Vascular Catheter With Metal Guide Wire 3Fr Single Lumen,Micro Introducer,Contrast Media Compatible, Size 45Cm Or More (Logline Iv) , Vascular Catheter 7Fr-16 Cm With Chlorhexidine, Silver Sulfadiazine Coated Triple Lumen , Vascular Catheter 5Fr/16G, Double Lumen Length 50Cm , Vascular Catheter 5Fr/16G, Double Lumen Length 55Cm , Vascular Catheter With Metal Guide Wire 5Fr Double Lumen, Introducer Safety Piv Catheter20g, 45Cm Or More (Logline Iv) , Vascular Catheter With Metal Guide Wire,5Fr Triple Lumen, Size Range 55Cm Or More (Logline Iv) , 3 Way Stop Cock , Non Pyrogenic And Single Use, Should Be Leak Proof, With Smooth Movements (Detail In Rc) , 3 Way Stop Cock With Extension Tube (Vein-O Extension Line) Size 10Cm (Non Pyrogenic & Single Use) (Detail In Rc) , 3 Way Stop Cock With Extension Tube (Vein-O Extension Line) Size 50Cm (Non Pyrogenic & Single Use) (Detail In Rc) , 3 Way Stop Cock With Extension Tube (Vein-O Extension Line) Size 100Cm (Non Pyrogenic & Single Use) (Detail In Rc) , 3 Way Stop Cock With Extension Tube (Vein-O Extension Line) Size 150Cm (Non Pyrogenic & Single Use) (Detail In Rc) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 16) (Detail In Rc) , Abdominal Drain Kit, Sterile, Having Drainage Catheter And Collection Bag (2000 Ml) (Size 20) (Detail In Rc) , Nasal Pronge Neonatal (Flexible Medical Grade, 2 Meter Long, Multichannel Kink Resistance Tube (Detail In Rc) , Elastic Adhesive Bandage Bp 10Cm X 1Mtr Stretched Length Adhesive Material Should Have Good Quality Sticking Property (Detail In Rc) , Sterile Disposable (Single Use Teflon/Ptfe I.V Cannula With Integrated 3 Way Stop Cock Size 26G (Detail In Rc) , Niv Mask (Noninvasive Ventilation Mask) Oro Nasal Covering (Nose & Mouth) Mask Adult Large Size For Ventilator Without Vent (Detail In Rc) , Niv Mask (Noninvasive Ventilation Mask) Oro Nasal Covering (Nose & Mouth) Mask Adult Medium Size For Ventilator Without Vent (Detail In Rc) , Niv Mask (Noninvasive Ventilation Mask) Oro Nasal Covering (Nose & Mouth) Mask Adult Large Size For Bipap With Vent (Detail In Rc) , Niv Mask (Noninvasive Ventilation Mask) Oro Nasal Covering (Nose & Mouth) Mask Adult Medium Size For Bipap With Vent (Detail In Rc) , Niv Mask (Noninvasive Ventilation Mask) Oro Nasal Mask Paediatric With Bronchoscopy And Co2 And O2 Port With Chin Support (Detail In Rc) , Nebulization Mask Adult (Detail In Rc) , Nebulization Mask Paediatric (Detail In Rc) , Chemotherapy Port And Non-Coring Needles(Adult) (Detail In Rc) , Chemotherapy Port & Non-Coring Needles(Pediatric) (Detail In Rc) , Core Biopsy Instrument With Compatible Co-Axial Needle (Automatic Disposal) , Disposable Bone Marrow Biopsy Needle , Eyelid Occlusion Dressing , Eye Pressure Shield , Oseltamivir Capsule Ip 75 Mg Capsule(Each Capsule Contains Oseltamivir Phosphate Equivalent To Oseltamivir 75 Mg) , Oseltamivir Capsule Ip 45 Mg Capsule(Each Capsule Contains Oseltamivir Phosphate Equivalent To Oseltamivir 45 Mg) , Oseltamivir Capsule Ip 30 Mg (Each Capsule Contains Oseltamivir Phosphate Equivalent To Oseltamivir 30 Mg) , Oseltamivir Phosphate For Oral Suspension Ip 12 Mg/Ml (Each Ml Contains 12 Mg Oseltamivir Base After Reconstitution) , Act Kit Containing 3 Tablets Of Artesunate(25Mg Each) And 1 Tablet Of Sulphadoxine And Pyrimethamine(250Mg+12.5Mg) , Act Kit Containing 3 Tablets Of Artesunate(50 Mg Each) And 1 Tablet Of Sulphadoxine And Pyrimethamine(500Mg+25Mg) , Act Kit Containing 3 Tablets Of Artesunate(100 Mg Each) And 1 Tablet Of Sulphadoxine And Pyrimethamine(750Mg+37.5Mg) , Act Kit Containing 3 Tablets Of Artesunate(150 Mg Each) And 2 Tablet Of Sulphadoxine And Pyrimethamine(500Mg+25Mg) , Each Combi Bliste Pack: Containing 3 Tablets Of Artesunate(200 Mg Each) And 2 Tablet Of Sulphadoxine Pyrimethamine(750Mg+37.5Mg)Each Or 3 Tablets Of Sulphadoxine Pyrimethamine(500+25)Mg , Liposomol Amphotericine Injection B 50Mg , Fentanyl 25Iu Patch [Nrd-233] , Fentanyl 50Iu Patch [Nrd-234] , Paracetamol Infusion 500 Mg With Both Temper Evident Caps Spray 10% Injection [Nrd-324] , Codiene Phosphate And Tripolidine Syrup (Each 5Ml Contains Codiene Phosphate 10Mg And Tripolidine 1.25Mg) [Nrd-476] , Paracetamol And Ibuprofen Syrup (Each 5Ml Contains Paracetamol 162.5Mg And Ibuprofen 100 Mg) 60Ml [Nrd-496] , Mefenamice Acid 100Mg/5Ml Syrup [Nrd-505] , Aceclofenac 100Mg And Thiocolchicoside 4Mg Tab. [Nrd-536] , Aceclofenac Sr 200 Mg Tab. [Nrd-537] , Aceclofenac And Paracetamol And Serratiopeptidase (100 And 325 And 15 Mg) Tab. [Nrd-538] , Buprinorphine Tablet 2Mg [Nrd-565] , Diclofenac Sodium 50Mg And Paracetamol 325Mg And Serratiopeptidase 10Mg Tablet [Nrd-605] , Etoricoxib And Thiocolchicoside(60 And 8 Mg) Tab. [Nrd-630] , Indomethacin 75 Mg Sr Tablet / Capsule [Nrd-646] , Morphine 10Mg Tab. I.P. [Nrd-695] , Paracetomol 650 Mg Tab. I.P. [Nrd-726] , Piroxicam Dt 20Mg Tab. I.P. [Nrd-739] , Serratiopeptidase 10Mg Tab. I.P. [Nrd-777] , Serratiopeptidase 20 Mg Tab. I.P. [Nrd-778] , Tapentadol 50Mg Tab. [Nrd-793] , Tramadol 37.5Mg And Paracetamol 325Mg Tab. [Nrd-802] , Trypsin 48Mg And Rutoside 100Mg And Bromelain 90 Mg Tablet [Nrd-806] , Trypsin Chymotripsin Tablet (Each Enteric Coated Tablet Contains 1 Lacks Unit Of Enzymetic Activity) [Nrd-807] , Desflurane, Usp, 100O/O Desflurane. Liquid For Inhalation [Nrd-61] , Lignocaine (Preservative Free) 2% Injection [Nrd-275] , Lignocaine Hydrochloride 2% 50Ml Vial Inj. Ip [Nrd-278] , Midazolam 5Mg/Ml Injection 10 Ml Vial [Nrd-294] , Rocuronium 100Mg/10Ml Inj. In 10 Ml Vial [Nrd-357] , Ropivacaine 0.75% 20Ml Vial Inj. Ip [Nrd-361] , Ropivacaine 0.75% 3 Ml Ampule (Heavy) Injection [Nrd-362] , Minocycline 100Mg. Capsule / Tablet [Nrd-29] , Artesunate Injection 120 Mg Each Combo Pack Contains Artesunate Inj 120Mg Vial, Sodium Bicarbonate Inj Ip 5% (2Ml Amp), Sodium Chloride Inj Ip 0.9%(10Ml Amp) [Nrd-156] , Azithromycin 10 Ml Vial Equaivelent To 500 Mg Inj. [Nrd-161] , Caspofungin 50 Mg Inj. [Nrd-176] , Caspofungin 70 Mg Inj. [Nrd-177] , Cefipime 1000Mg And Tazobactum 125Mg Inj. [Nrd-178] , Cefoperazone 1Gm And Tazobactum 125Mg Inj. [Nrd-179] , Cefoperazone 500Mg Inj. Ip [Nrd-180] , Ceftazidime 1Gm And Sulbactam500 Mg Inj. [Nrd-181] , Ceftazidime 2Gm And Avibactum 500Mg Inj. [Nrd-182] , Ceftriaxone Ip 125 Mg Inj. Ip [Nrd-184] , Ceftriaxone 1000Mg And Salbactum 500Mg And Disodium Edetate 37Mg Inj [Nrd-185] , Ceftriaxone 100Mg And Sulbactam 500Mg Injection (Detail In Rc) [Nrd-186] , Cefuroxime 1Gm Injection [Nrd-188] , Clarithromycin 500Mg Inj. Bp [Nrd-194] , Clindamycin 600Mg/4Ml Inj. Ip In 4 Ml Vial [Nrd-195] , Doxycycline For Injection 100 Mg Inj. Usp [Nrd-221] , Ertapenem Sodium 1.046 Gm Equivalent To Ertapenem 1Gm Inj. [Nrd-230] , Fluconazole 200 Mg Inj. [Nrd-236] , Levofloxacine 500Mg/100 Ml Inj. Ip 100Ml Infusion [Nrd-273] , Moxifloxin 400Mg/100Ml Inj. [Nrd-301] , Netilmycin 300Mg/3Ml Inj. Ip 3Ml Vial/Ampoule [Nrd-308] , Piperacillin 1 Gm And Tazobactum 125 Mg Inj. Ip [Nrd-335] , Streptomycin 500Mg Injection [Nrd-369] , Teicoplanin 200 Mg Inj. Ip [Nrd-371] , Teicoplanin 400 Mg Inj. Ip [Nrd-372] , Tigecycline For Injection 50Mg Inj. Usp [Nrd-379] , Tobaramycin 80Mg Inj. Ip [Nrd-381] , Dolutegravir 50, Each Film Coated Tablet Contain Dolutegravir Sodium 50 Mg [Nrd-388] , Nevirapine 200 Each Tablet Contain Nevirapine 200Mg [Nrd-457] , Fosfomycin Trometamol Powder 3Gm [Nrd-463] , Atazanavir300 Andritonavir100, Each Tablet Contain Atazanavir Sulphate Ip 300Mg Andritonavir Ip100mg [Nrd-470] , Cefaclor Each 5 Ml Contain Cefaclor 125 Mg Syp. I.P. [Nrd-475] , Cefixime Oral Suspension/Dry Syrup 50Mg Each 5 Ml Contain Cefixime Oral Suspension/Dry Syrup 50Mg [Nrd-482] , Cefixime Oral Suspension / Dry Syrup 100Mg Each 5 Ml Contain Cefixime Oral Suspension/Dry Syrup100mg [Nrd-483] , Cefpodoxime Proxetil Oral Suspension 50Mg Syrup I.P. Each 5 Ml Contain Cefpodoxime Proxetil Oral Suspension 50Mg Syrup I.P. [Nrd-484] , Cefpodoxime Proxetil Oral Suspension 100Mg Syrup I.P. Each 5 Ml Contain Cefpodoxime Proxetil Oral Suspension 100Mg Syrup I.P. [Nrd-485] , Cefuroxime Axetil Oral Suspension 125Mg/5Ml Syrup B.P. [Nrd-486] , Clarithromycin For Oral Suspension / Dry Syrup 125Mg/5Ml [Nrd-487] , Cefoperazone Injection 1Gm [Nrd-488] , Levofloxacin Oral Solution/ Syrup 125Mg /5Ml [Nrd-503] , Linezolid 100Mg/5Ml In 30Ml Syrup [Nrd-504] , Nitrofurantoin Oral Suspension 25Mg/5Ml In 100Ml Syrup B.P. [Nrd-509] , Azithromycin 100Mg/5Ml Oral Syrup /Suspension [Nrd-525] , Azithromycin 200Mg/5Ml Oral Syrup /Suspension [Nrd-526] , Cefixime And Potassium Clavulanate 200 And 125Mg Tab. [Nrd-570] , Cefpodoxime Proxetil Tablet 100Mg / Cefpodoxime Proxetil Dispersibletablet 100Mg [Nrd-571] , Cefpodoxime 200Mg Tab. I.P. [Nrd-572] , Cefpodoxime Cv 325 Tab [Nrd-573] , Clarithromycin 250 Mg Tab. I.P. [Nrd-580] , Clarithromycin 500Mg Tab. I.P. [Nrd-581] , Co Trimoxazole Tablet Ip 480Mg (Trimethoprim 80Mg And Sulphamethoxazole 400Mg) [Nrd-590] , Cefuroxime Axetil 500 Mg. Tab. I.P. [Nrd-591] , Ivermectin 6 Mg And Albendazole 400 Mg Tab. [Nrd-649] , Ivermectin 6Mg Tab. I.P. [Nrd-650] , Ivermectin 12Mg Tab. I.P. [Nrd-651] , Ketoconazole 200 Mg Tab. I.P. [Nrd-652] , Levofloxacin 750 Mg Tab. I.P. [Nrd-663] , Lopinavir 200Mg And Ritonavir 50 Mg Tab. I.P. [Nrd-669] , Moxifloxacin 400 Mg Tab. B.P. [Nrd-697] , Nitazoxanide 500Mg Tab. [Nrd-713] , Rifampicin 450 Mg Tab. I.P. [Nrd-762] , Rifampicin 600 Mg Tab. I.P. [Nrd-763] , Rifaximin 200 Tab. B.P. [Nrd-764] , Rifaximin 550Mg Tab. B.P. [Nrd-765] , Sofosbuvir 400 Mg And Velpatasvir 100 Mg Tab. [Nrd-784] , Tenofovir 300Mg Tab. [Nrd-795] , Voriconazole 200 Mg Tab. I.P. [Nrd-809] , Abacavir300 Each Tablet Contain Abacavir 300Mg Ip [Nrd-825] , Lamivudine 100 Each Tablet Contain Lamivudine 100 Mg [Nrd-826] , Zideovudine 60Mg And Lamivudine 30Mg [Nrd-828] , Entecavir 1Mg Tab./Cap Film Coated [Nrd-894] , Hydroxyzine Hydrochloride Oral Solution / Drop 6Mg/Ml [Nrd-76] , Ambroxol Drop 7.5Mg/Ml 15Ml [Nrd-77] , Anticold Drop (Each Ml Contains Paracetamol 125Mg, Chlorpheniramine Maleate 1Mg And Phenylepherine Hydrochloride 2.5 Mg) 15 Ml [Nrd-78] , Methylprednisolon Acetate 40Mg Inj. Ip [Nrd-291] , Methylprednisolon Acetate 125Mg Injection [Nrd-292] , Phenylephrine Hydrochloride 10 Mg/Ml Inj. Bp/Ip 1Ml Vial [Nrd-333] , Deflazacort 6Mg Tab. [Nrd-602] , Deflazacort 12 Mg Tab. [Nrd-603] , Methylprednisolone 4Mg Tab. I.P. [Nrd-682] , Methylprednisolone 16Mg Tab. I.P. [Nrd-683] , Methylprednisolone 8Mg Tab. I.P. [Nrd-684] , Prednisolone Ip 40Mg Tab. I.P. [Nrd-746] , Disulfiram Tablet 500Mg [Nrd-611] , Disulfiram 250Mg Tab. I.P. [Nrd-612] , Naltrexone 50 Mg Tab. I.P. [Nrd-701] , Lacosamide Infusion 200Mg [Nrd-271] , Piracetam 200Mg Inj. [Nrd-336] , Phenobarbitone 20Mg/5Ml In 100Ml Syrup [Nrd-512] , Piracetam 500Mg/5Ml Suspension/Syrup [Nrd-514] , Lacosamide 50 Mg Tab. B.P. [Nrd-653] , Lamotrigine Dispersible 100Mg Tab. I.P. [Nrd-654] , Levetiracetam Ip 250 Mg Tab. I.P. [Nrd-660] , Levodopa And Carbidopa And Entacapone 100Mg/25Mg/200Mg Tab. [Nrd-662] , Oxcarbazepine 300Mg Tab. I.P. [Nrd-721] , Oxcarbazepine 450Mg Tab. I.P. [Nrd-722] , Topiramate 50Mg Tab. I.P. [Nrd-800] , Zonisamide 50Mg Tab. [Nrd-820] , Zonisamide 100 Mg Tab. [Nrd-821] , Alectinib 150 Mg Cap. [Nrd-9] , Aprepitant 125 / 80 Mg Capsule / Tablet Kit (Each Kit Contains 1 Capsule / Tablet Of 125 Mg And 2 Capsule / Tablet Of 80Mg) [Nrd-12] , Ceritinib Capsule 150Mg [Nrd-18] , Cyclosporine 100 Mg Cap. Ip [Nrd-20] , Dacarbazine 200 Mg Inj. Usp [Nrd-21] , Mycophenolate Mofetil 500Mg Capsule / Tablet [Nrd-30] , Rucaparib 200 Mg Cap. [Nrd-33] , Rucaparib 300 Mg Cap. [Nrd-34] , Temozolamide 250 Mg Cap. Ip [Nrd-37] , Docetaxel Injection 80 Mg/4Ml [Nrd-143] , Adalimumab 40 Mg Inj. [Nrd-147] , Avelumab 200 Mg Inj. [Nrd-158] , Azacitidine 100Mg Inj. [Nrd-160] , Bortezomib 2.5Mg Inj. [Nrd-163] , Cabazitaxel Injection 60 Mg [Nrd-167] , Carfilzomib 60 Mg Inj. [Nrd-174] , Carmustine 100 Mg Inj. Ip [Nrd-175] , Cetuximab 100 Mg Inj. [Nrd-190] , Cetuximab 500Mg Inj. [Nrd-191] , Cladrabine 10 Mg Inj. [Nrd-193] , Cytarabine 1000 Mg Inj. Ip [Nrd-199] , Daratumumab 100 Mg Inj. [Nrd-202] , Daratumumab400 Mg Inj. [Nrd-203] , Darbepoietin Alfa 100Mcg Inj. [Nrd-204] , Darbepoietin Alfa 200 Mcg Inj. [Nrd-205] , Darbepoietin Alfa 500Mcg Inj. [Nrd-206] , Decitabine 50 Mg Inj. [Nrd-207] , Degarelix 80 Mg Inj. [Nrd-209] , Degarelix 120 Mg Inj. [Nrd-210] , Denosumab 120 Mg Inj. [Nrd-212] , Docetaxel 120 Mg Inj. Ip [Nrd-220] , Durvalumab 120 Mg Inj. [Nrd-222] , Durvalumab 500Mg Inj. [Nrd-223] , Eribulin 0.5Mg Inj. [Nrd-228] , Eribulin 1 Mg Inj. [Nrd-229] , Fludarabine Phosphate Injection 100Mg Inj. Ip [Nrd-237] , Fludarabine Phosphate Injection 50Mg Inj. Ip [Nrd-238] , Fulvestrant 250Mg Inj. [Nrd-246] , Goserelin Acetate Implant 3.6 Mg Inj. Bp [Nrd-249] , Horse Atg(Anti Thymocyte Globulin) 250 Mg Inj. [Nrd-252] , Interferon Beta 1 A Injection 30Mcg [Nrd-262] , Irinotecan Injection 40Mg/2Ml 2 Ml Vial [Nrd-267] , Irinotecan 100 Mg/5Ml Inj. Ip 5Ml Vial [Nrd-268] , Liposomal Doxorubicin Hydrochloride 20Mg/10Ml Injection 10Ml Vial/Ampoule [Nrd-279] , Liposomal Doxorubicin Hydrochloride 50Mg/25Ml Injection 25Ml Vial/Ampoule [Nrd-280] , Mesna 200 Mg/2Ml (Sod. Mercaptoethane Sulphate) Inj. 2 Ml Ampoule [Nrd-287] , Methotrexate 250 Mg Inj. Ip [Nrd-288] , Methotrexate 1000 Mg Inj. Ip [Nrd-289] , Metotrexate 15Mg (Preservative Free) Injection [Nrd-293] , Mitomycin 2 Mg Inj. Ip [Nrd-296] , Mitomycin 40 Mg Inj. Ip [Nrd-297] , Nabpaclitaxel / Paclitaxel Nano Particle Injection 100 Mg [Nrd-303] , Natalizumab 300 Mg Inj. [Nrd-306] , Nimotuzumab 50 Mg Inj. [Nrd-312] , Octreotide Lar (Long Acting Release) 30 Mg Inj. [Nrd-319] , Peg Asparaginase 3750 Iu 5 Ml Inj. [Nrd-326] , Peg Filgrastim Injection 6Mg Inj. [Nrd-327] , Pemetrexed 100Mg Inj. Ip [Nrd-330] , Pemetrexed 500 Mg Inj. Ip [Nrd-331] , Plerixafor 24 Mg Inj. [Nrd-338] , Ranibizumab Injection (10Mg/Ml) 2.3Mg/0.23Ml Per Vial [Nrd-346] , Rasburicase 1.5 Mg Inj. [Nrd-347] , Rituximab 100 Mg Inj. [Nrd-355] , Rituximab 500 Mg Inj. [Nrd-356] , Topotecan 2.5 Mg Inj. Ip [Nrd-383] , Topotecan 4 Mg Inj. Ip [Nrd-384] , Trabectedin 1 Mg Inj. [Nrd-387] , Trastuzumab 440 Mg Inj. [Nrd-389] , Trastuzumab150mg Inj. [Nrd-390] , Vinorelbine 10Mg Inj. Ip [Nrd-400] , Vinorelbine 50Mg Inj. Ip [Nrd-401] , Cyclosporine Oral Solution 100Mg/Ml Syrup I.P. [Nrd-489] , Rabbit Atg (Anti Thymocyte Globulin) 25Mg / 5Ml Inj. [Nrd-490] , Hydroxyurea 500Mg Tab./Cap. I.P. [Nrd-528] , Everolimus 5Mg Tab./Cap. [Nrd-530] , Everolimus 10Mg Tab./Cap. [Nrd-531] , Tacrolimus 0.25 Tab./Cap. I.P. [Nrd-532] , Nintedanib 150Mg Tab./Cap. [Nrd-533] , 6-Mercaptopurine Tablet 20Mg [Nrd-534] , Afatinib 20 Mg Tab. [Nrd-539] , Afatinib 30 Mg Tab. [Nrd-540] , Afatinib 40 Mg Tab. [Nrd-541] , Alpelisib 150 Mg Tab. [Nrd-544] , Alpelisib 250 Mg Tab. [Nrd-546] , Axitinib 5 Mg Tab. [Nrd-559] , Capmatinib 200 Mg Tab. [Nrd-568] , Dabrafenib Capsule / Tablet 50 Mg [Nrd-596] , Dacomitinib 15 Mg Tab. [Nrd-597] , Eltrombopag 25Mg Tablet / Capsule [Nrd-617] , Eltrombopag 50Mg Tablet / Capsule [Nrd-618] , Erlotinib 150 Mg Tab. I.P. [Nrd-622] , Erlotinib 100Mg Tab. I.P. [Nrd-623] , Enzalutamide 40Mg Tablet / Capusle [Nrd-627] , Ibrutinib 140Mg Tablet / Capsule [Nrd-645] , Lapatinib Tablet 250Mg [Nrd-655] , Lenalidomide 25Mg Tab. [Nrd-656] , Lenalidomide 10 Mg Tab. [Nrd-657] , Lenvatinib 4 Mg Tab. [Nrd-658] , Lenvatinib 10 Mg Tab. [Nrd-659] , Melphalan 2Mg Tab. I.P. [Nrd-675] , Nilotinib 150 Mg Tablet / Capsule [Nrd-710] , Nilotinib 200 Mg Tablet / Capsule [Nrd-711] , Olaparib 100 Mg Tablet [Nrd-716] , Olaparib 150 Mg Tablet [Nrd-717] , Osimertinib 80 Mg Tablet [Nrd-720] , Pazopanib 200Mg Tablet / Capsule [Nrd-729] , Pazopanib 400Mg Tablet / Capsule [Nrd-730] , Pomalidomide 2 Mg Tab. [Nrd-740] , Pomalidomide 4 Mg Tab. [Nrd-741] , Regorafenib 40 Mg Tab. [Nrd-757] , Ribociclib 200 Mg Tab. [Nrd-760] , Ruxolitinib 5 Mg Tablet / Capsule [Nrd-772] , Ruxolitinib 15 Mg Tablet / Capsule [Nrd-774] , Ruxolitinib 20 Mg Tablet / Capsule. [Nrd-775] , Sorafenib 200 Mg Tab. I.P. [Nrd-786] , Sunitinib 12.5 Mg Tab. [Nrd-788] , Sunitinib 25 Mg Tab. [Nrd-789] , Sunitinib 50 Mg Tab. [Nrd-790] , Tacrolimus 1Mg Tablet / Capsule [Nrd-791] , Tegafur 100Mg And Uracil 224Mg Capsule [Nrd-794] , Tofacitinib 5 Mg Tab. [Nrd-798] , Amantadine 100Mg Tablet / Capsule [Nrd-547] , Rasagiline1mg Tab. [Nrd-756] , Ropinirole 0.25Mg Tab. I.P. [Nrd-770] , Selegiline 5Mg Tab. I.P. [Nrd-776] , Povidone Iodine Gargle 0.5% W/V [Nrd-128] , Ramipril Ip 5 Mg Capsule / Tablet Ip [Nrd-32] , Metoprolol 1Mg/Ml Inj. [Nrd-141] , Enalaprilat Injection 1.25Mg/Ml In 1Ml Ampoule [Nrd-224] , Fondaparinux 2.5Mg Inj. Usp [Nrd-242] , Telmisartan40mg And Hydroclorothiazide12.5 Mg, I.P. Each Tablet Contain Telmisartan40mg And Hydroclorithiazide12.5 Mg, [Nrd-247] , Hydralazine 20Mg/Ml Inj. Ip 1Ml Vial/Ampoule [Nrd-255] , Enoxaparin Sodium Injection (Low Molecular Wt. Heparin) 40Mg/0.4Ml 0.4Ml Injection [Nrd-284] , Mephentermine 30Mg/Ml Injection 10Ml Vial [Nrd-285] , Nimodipine Infusion 10Mg/50 Ml Inj. Bp 50Ml [Nrd-311] , Reteplase 18 Mg Inj. [Nrd-352] , Tenecteplase 20Mg Inj. [Nrd-373] , Tenecteplase 40 Mg Inj. [Nrd-374] , T Pa 20Mg Alteplase For Injection [Nrd-385] , T Pa 50Mg Alteplase For Injection [Nrd-386] , Amlodipine Oral Solution 1 Mg/ Ml Syrup B.P. [Nrd-477] , Midodrine 5Mg Tab. [Nrd-527] , Apixaban 2.5 Mg Tab. [Nrd-549] , Apixaban 5Mg Tab. [Nrd-550] , Bosentan 62.5 Mg Tab. I.P. [Nrd-562] , Chlordiazepoxide 5 Mg And Clidinium 2.5 Mg Tablet [Nrd-575] , Chlorthalidone 6.25 Mg Tab. I.P. [Nrd-576] , Cilostazol 50Mg Tab. I.P. [Nrd-578] , Cilostazol 100Mg Tab. I.P. [Nrd-579] , Cilnidipine 5 Mg Tab. I.P. [Nrd-582] , Cilnidipine10 Mg Tab. I.P. [Nrd-583] , Cilnidipine 20 Mg Tab. I.P. [Nrd-584] , Dabigatran 150 Mg Tab. [Nrd-594] , Dabigatran 110 Mg Tab. [Nrd-595] , Diltiazem Cr/Prolonged Released Tablet 90Mg [Nrd-608] , Ivabradine 5Mg Tab. [Nrd-648] , Moxonidine 0.2 Mg Tab. B.P. [Nrd-698] , Moxonidine 0.3 Mg Tab. B.P. [Nrd-699] , Nebivolol 5Mg Tab. I.P. [Nrd-702] , Nebivolol 10Mg Tab. I.P. [Nrd-703] , Nicorandil 5Mg Tab. I.P. [Nrd-704] , Nicoumalone 1 Mg Tab. I.P. [Nrd-705] , Nicoumalone 3 Mg Tab. I.P. [Nrd-706] , Nicoumalone 4 Mg Tab. I.P. [Nrd-707] , Nifidipine Capsule 10Mg [Nrd-708] , Nifidipine 20Mg Sr Tab. I.P. [Nrd-709] , Olmesartan Medoxomil 20 Mg Tab. I.P. [Nrd-718] , Prasugrel 10Mg Tab Tab. [Nrd-744] , Prazosin 5Mg Tab. Er/Pr/Cr [Nrd-745] , Propranolol 10Mg Tablet / Capsule [Nrd-751] , Propranolol 40 Mg Sr Tablet / Capsule [Nrd-752] , Ranolazine 500Mg Tab. Er/Pr/Cr [Nrd-755] , Rivaroxaban 10Mg Tab. B.P. [Nrd-766] , Rivaroxaban 15Mg Tab. B.P. [Nrd-767] , Rivaroxaban 20Mg Tab. B.P. [Nrd-768] , Rosuvastatin 10Mg And Fenofibrate 160Mg Tab. I.P. [Nrd-771] , Ticagrelor 90Mg Tablet / Capsule [Nrd-797] , Tolvapatan 15Mg Tab. [Nrd-799] , Trimetazidine Hcl Modified Release Tablet 35Mg [Nrd-804] , Trimetazidine Hydrochloride Modified Release (Cr/Sr/Pr) 60 Mg Capsule/Tablet [Nrd-805] , Verapamil Hydrochloride Tablet Sustained Release 120Mg [Nrd-811] , Warfarin 1Mg Tab. I.P. [Nrd-815] , Warfarin 2Mg Tab. I.P. [Nrd-816] , Warfarin 3Mg Tab. I.P. [Nrd-817] , Chlorthalidone 12.5 Mg Tab [Nrd-902] , Chlorthalidone 25Mg Tablet [Nrd-903] , Acitretin 10 Mg Cap. Ip [Nrd-7] , Acitretin 25 Mg Cap. Ip [Nrd-8] , Isotretinoin 10Mg Cap. Ip [Nrd-26] , Isotretinoin 20 Mg Cap. Ip [Nrd-27] , Amorolfine 0.25% Cream [Nrd-46] , Azelaic Acid 20% Cream [Nrd-47] , Benzoyl Peroxide Gel 2.5 % Ip [Nrd-48] , Desonide 0.05% Cream [Nrd-49] , Glycolic Acid 6% Cream [Nrd-51] , Hydrocortisone 1% Cream Ip [Nrd-52] , Hydroquinone 2% Cream Usp [Nrd-53] , Luliconazole 1% Cream Ip [Nrd-55] , Mometasone 0.1 % Cream Ip [Nrd-56] , Neomycin Sulphate 0.5% Cream [Nrd-58] , Adaplene (0.1% W/W) Gel [Nrd-60] , Secukinumab 150 Mg Inj. [Nrd-363] , Clotrimazole 1% And Beclomethasone 0.025% Lotion [Nrd-411] , Ketaconazole 2% Lotion [Nrd-412] , Minoxidil 5% Lotion [Nrd-414] , Sunscreen Lotion Spf 30 (Octinoxate 7.5%, Avobenzone 2%, Oxybenzone 3%, Octocrylene 3% And Zinc Oxide 2%) 50Ml [Nrd-418] , Clotrimazole 10Mg Lozenses [Nrd-419] , Neomycin Sulphate And Bacitracin Zinc Ointment Usp 5 Mg And 500 Iu/Gm Ointment Usp [Nrd-431] , Neomycin, Polmyxin And Bacitracin Zinc Ophthalmic 15 Gm Ip Ointment [Nrd-438] , Tacrolimus 0 .03% Ointment [Nrd-439] , Tacrolimus 0 .1% Ointment [Nrd-440] , Mercunium Chloride Paint [Nrd-444] , Furosemide 20Mg And Spironolactone 50Mg Tab. [Nrd-643] , Torsemide 20Mg Tab. I.P. [Nrd-801] , Racecadotril 100Mg Cap. Ip [Nrd-5] , Diastase, Pepsin With Simethicone 15Ml Drop Each Ml Contains Diastase (1:1200) 33.33Mg, Pepsin (1:3000) 5Mg And Simethicone Emulsion 40Mg [Nrd-71] , Lactulose Enema 20% [Nrd-87] , Hepato Protective Tablet Each Film Coated Tablet To Contain: Matadoxine 500Mg, Silymarin 140Mg, L-Ornithine L-Aspartate 150Mg, Pyridoxine Hydrochloride 3Mg, Folic Acid 1.5Mg [Nrd-171] , Mefenamic Acid 250Mg And Dicyclomine Hydrochloride10mg Each Tablet Contain Mefenamic Acid 250Mg And Dicyclomine Hydrochloride10mg [Nrd-259] , Ornidazole 500Mg Inj. Ip [Nrd-322] , Palonosetron 0.25Mg Inj. [Nrd-323] , L-Ornithine L-Aspartate (150Mg) And Pancreatin (100Mg) Capsule / Tablet [Nrd-409] , Bacillus Clausii Spores Suspension 2 Billion/5Ml [Nrd-452] , Racecadotril 10 Mg [Nrd-467] , Cyproheptadine Hcl 2Mg / 5Ml Syrup I.P. [Nrd-491] , Drotavarine Hcl 20Mg / 5Ml Syrup/Suspension [Nrd-494] , Each 15 Ml Contains: Milk Of Magnesia 11.25 Ml And Liquid Paraffin 3.75 Ml 170 Ml Syrup [Nrd-495] , Enzyme Syrup (Each 5Ml Contains Diastase 50Mg And Pepsin 10Mg) 100Ml [Nrd-497] , Ondansetron Oral Suspension/Solution/ Syrup 2Mg/5Ml [Nrd-510] , Potassium Magnesium Citrate Syrup/ Solution Each 5Ml Contians Potassium Citrate 1100Mg And Magnesium Citrate 375 Mg [Nrd-515] , Ranitidine 75 Mg /5Ml Oral Suspension/Solution /Syrup I.P. [Nrd-516] , Sodium Picosulphate Oral Suspension/ Solution/ Syrup 5Mg/5Ml [Nrd-519] , Sorbitol And Tricholine Citrate Syrup / Solution Each 10Ml Contains Sorbitol (70%) 7.15Gm And Tricholine Citrate (66%) 0.55Gm [Nrd-520] , Sucralphate Syrup/ Suspension Each 5Ml Contains Sucralphate 500Mg [Nrd-521] , Cyproheptadine 4Mg Tab. I.P. [Nrd-592] , Esomeprazole 40 Mg Tab. I.P. [Nrd-624] , Pantoprazole 20Mg Tab. I.P. [Nrd-725] , Romiplostim 250 Mcg Inj. [Nrd-359] , Romiplostim 500 Mcg Inj. [Nrd-360] , Human Albumin 20% In 50 Ml Vial Inj. [Nrd-823] , Glycopegylated Extended Half Life Nonacog Beta Pegol F Ix 500Iu [Nrd-889] , Glycopegylated Extended Half Life Nonacog Beta Pegol F Ix 1000Iu [Nrd-890] , Glycopegylated Extended Half Life Factor Viii 500Iu [Nrd-891] , Glycopegylated Extended Half Life Factor Viii 1000Iu [Nrd-892] , Nandrolone Decanoate 100Mg Inj. Ip [Nrd-304] , Nandrolone Decanoate 50 Mg Inj. Ip [Nrd-305] , Alendronate Sodium 70 Mg Tab. I.P. [Nrd-542] , Cholchicine 0.5Mg Tab. I.P. [Nrd-577] , Febuxostat 40 Mg Tab. [Nrd-632] , Febuxostat 80 Mg Tab. [Nrd-633] , Silodosin 4 Mg Tablet / Capsule [Nrd-35] , Silodosin 8 Mg Tablet / Capsule [Nrd-36] , Alfuzosin 10 Mg Tab. I.P. [Nrd-543] , Calcium Acetate 667 Tab. Usp [Nrd-566] , Sevelamer Carbonate 800 Mg Tab. [Nrd-779] , Sildosin 8 Mg And Dutasteride 0.5 Mg Tablet / Capsule [Nrd-780] , Solifenacin Succinate 10 Mg Tab. I.P. [Nrd-785] , Formetrol 12Mcg And Budesonide 400 Mcg. Powder For Inhalation [Nrd-24] , Indacaterol And Glycopyronium Inhalation Powder 110/50 Mcg Cap. [Nrd-25] , Salmetrol 50Mcg And Fluticasone 500 Mcg Dpi Ip [Nrd-65] , Budesonide 400 Mcg Dpi Ip [Nrd-66] , Levosalbutamol 100Mcg And Ipratropium Bromide 40Mcg Dpi [Nrd-70] , Inj.Caffeine Cirate 20Mg/Ml [Nrd-169] , Ephedrine 30 Mg/Ml Inj. Bp In 1Ml Ampoule [Nrd-225] , Omalizumab 150 Mg Vial Inj. [Nrd-321] , Formoterol 6 Mcg. And Budesonide 400 Mcg. Mdi Ip [Nrd-424] , Levosalbutamol 50Mcg. And Ipratropium 40Mcg. Mdi [Nrd-425] , Levosalbutamol Inhalation Solution 50Mcg [Nrd-426] , Fluticasone Propionate Nasal Spray Ip 50Mcg [Nrd-429] , Formeterol 20Mcg And Budesonide 0.5Mg Respitory Solution/ Suspension [Nrd-453] , Levosalbutamol 1.25Mg And Ipratropium 500Mcg Respiratory Solution 2.5Ml [Nrd-454] , Budesonide 0.5Mg/Ml Respiratory Solution [Nrd-456] , Glycopyrronium Inhalation Solution 25Mcg 2 Ml [Nrd-458] , Tiotropium Bromide Powder For Inhalation 18Mcg [Nrd-460] , Dextromethorphan Hbr And Chlorpheniramine Syrup (Each 5Ml Contains Dextromethorphan Hbr 10Mg And Chlorpheniramine 2Mg) [Nrd-492] , Montelucast And Levocetrizine Syrup/Suspension Each 5Ml Contains Montelucast 4Mg And Levocetrizine 2.5 Mg [Nrd-508] , Acebrophylline Sr 200 Mg Tab. [Nrd-535] , Bilastin 20 Mg Tab. [Nrd-560] , Fexofenadine 120 Mg Tab. I.P. [Nrd-634] , Fexofenadine 180 Mg Tab. I.P. [Nrd-635] , Loratadine 10 Mg Tab. I.P. [Nrd-670] , Montelukast 4 Mg Tab. I.P. [Nrd-692] , Montelukast 5 Mg Tab. I.P. [Nrd-693] , Montelukast 10 Mg Tab. I.P. [Nrd-694] , N Acetylecystine Effervescent Form, Orange Flavour, 600 Mg Tab. [Nrd-700] , Pheniramine 25 Mg Tab. I.P. [Nrd-735] , Pirfenidone 200 Mg Tab. I.P. [Nrd-737] , Pirfenidone 400 Mg Tab. I.P. [Nrd-738] , Posaconazole 100Mg Tab. [Nrd-742] , Posaconazole 40Mg/Ml Syp. [Nrd-743] , Tiotropium Inhalation 9Mcg [Nrd-822] , Danazol 100Mg Cap. Ip [Nrd-22] , Cetrorelix Acetate 0.25 Mg Inj. [Nrd-189] , Combikit Of (Tab Fluconazole150mg And Azithromycin 1Gm And Secnidazole1gm) Each Kit Contain 1Tab Fluconazole150mg And 1 Tab.Azithromycin 1Gm And 2 Tab.Secnidazole1gm . [Nrd-270] , Recombinant Fsh 150 Iu Inj. [Nrd-348] , Recombinant Fsh 300Iu Inj. [Nrd-349] , Recombinant Lh 75Iu Inj. [Nrd-351] , Dydrogesterone 10Mg Tab. I.P. [Nrd-616] , Estradiol Valerate 2 Mg Tab. [Nrd-625] , Ethynil Estradiol 0.02Mg And Desogestral 0.15Mg Tablets [Nrd-628] , Desogestrel 0.075Mg Tablet [Nrd-750] , Ulipristal 5Mg Tab. [Nrd-808] , Prostaglandin 500Mcg/Ml Inj. 1 Ml Vial [Nrd-151] , Progesterone Injection 50 Mg Inj. Bp [Nrd-155] , Degludec Insulin 100Iu/Ml Injection 3Ml [Nrd-211] , Detemir Insuline 100Iu/Ml Injection 3Ml [Nrd-214] , Fsh 75 Iu Inj. [Nrd-244] , Hp Hmg (Highly Human Menopausal Parodied Gonadotropin) 150 Iu Inj. Ip [Nrd-253] , Insulin Aspart 100Iu/Ml Injection 3 Ml [Nrd-258] , Insulin Glulisine (Monocomponent Insulin Glulisine) 100 Iu/Ml Injection 3 Ml [Nrd-260] , Insulin Lispro Injection [Nrd-261] , Invert Sugar Injection Ip 10% W/V [Nrd-264] , Triptorelin 3.75 Mg Inj. [Nrd-395] , Triptorelin 11.25 Mg Inj. [Nrd-396] , Insulin Glargine 300 Iu Per Ml Inj. Ip 1 Prefilled Pen Of 1.5Ml [Nrd-403] , Carbimazole 10 Mg Tab. I.P. [Nrd-569] , Cyproterone Acetate 2 Mg And Ethynil Estradiol. 035Mg Tab Bp [Nrd-593] , Dapagliflozin 10 Mg Tab. [Nrd-599] , Levothyroxine Sodium 25 Mcg Tab. I.P. [Nrd-665] , Levothyroxine Sodium 75 Mcg Tab. I.P. [Nrd-666] , Linaglipitin 5Mg Tab. [Nrd-668] , Megestrol Acetate 160 Mg Tab. I.P. [Nrd-673] , Melatonin 3 Mg Tab. [Nrd-674] , Methimazole Tablet 5Mg [Nrd-677] , Methimazole 10Mg Tab. Usp [Nrd-678] , Repaglinide 1Mg Tab. [Nrd-759] , Sitagliptine And Metformin (50/500) Tab [Nrd-782] , Vildagliptin 50Mg Tab. I.P. [Nrd-812] , Voglibose 0.2 Mg Tab Tab. I.P. [Nrd-813] , Voglibose 0.3 Mg Tab Tab. I.P. [Nrd-814] , Dapagliflozin 5Mg Tablet [Nrd-901] , Tetanus Vaccine (Adsorbed) Ip In 0.5 Ml Inj. [Nrd-824] , Botulinum Toxin Type A For Injection 100 Iu [Nrd-164] , Botulinum Toxin Type A For Injection 50 Iu [Nrd-165] , Sildenafil Injection 0.8Mg [Nrd-364] , Atomoxetin 10 Mg Tab. [Nrd-555] , Atomoxetin 18 Mg Tab. [Nrd-556] , Atomoxetin 25 Mg Tab. [Nrd-557] , Dapoxetine 30 Mg Tab. I.P. [Nrd-600] , Donepezil 5 Mg Tab. I.P. [Nrd-613] , Flunarizine 10Mg Tab. [Nrd-638] , Rizatriptan 10Mg Tab. I.P. [Nrd-769] , Sildenafil 20 Mg Tab. I.P. [Nrd-783] , Tetrabenazine 25Mg Tab. [Nrd-796] , Triamcinolone Oromucosal Paste Bp 0.1% W/W [Nrd-886] , Nicotine 2Mg Tab [Nrd-899] , Nicotine 4Mg Tab [Nrd-900] , Natamycin Opthalmic Suspension 5% Eye Drop Ip [Nrd-94] , Olapatadine 0.1% And Ketorolac 0.4% Ophthalmic Solution [Nrd-95] , Brinozolamide 1% W/V And Brimonidine Tartrate 0.2% W/V Ophthalmic Suspension [Nrd-98] , Cyclopentolate 1% Eye Drop Ip [Nrd-100] , Dorzolamide 2% Eye Drop Ip [Nrd-101] , Fluromethalone 0.1% Eye Drop [Nrd-102] , Gatifloxacin 0.30% And Prednisolone Acetate 1% Ophthalmic Suspension [Nrd-103] , Hpmc 0.3% Eye Drop [Nrd-104] , Itraconazole 1% Eye Drop [Nrd-105] , Moxifloxacin 0.5% And Ketorolac Tromethamine 0.5% Eye Drop [Nrd-107] , Moxifloxacin 0.5% And Dexamethasone 0.1% Eye Drops [Nrd-108] , Moxifloxacin 0.5% And Prednisolone 1% Ophthalmic Solution [Nrd-109] , Nepafenac 0.1% Eye Drop [Nrd-110] , Proparacaine 0.5% W/V Eye Drop Usp [Nrd-114] , Sodium Chloride 5 % Eye Drop Bp [Nrd-115] , Travapost 0.004% And Timolol 0.5% Eye Drops Ip [Nrd-117] , Tropicamide 0.8% W/V And Phenylphrine Hcl 5% W/V Eye Drop [Nrd-118] , Voriconazole 1 % W/V (Lyophilized) 30Mg Eye Drop [Nrd-119] , Azithromycin 1% Eye Ointment [Nrd-120] , Chloramphenicol 1%, Polymyxin B Sulphate (10000 Units) And Dexamethasone 0.1% Sodium Phosphate Eye Ointment [Nrd-123] , Itraconazole 1% Eye Ointment [Nrd-125] , Moxifloxacin 0.5% Eye Ointment [Nrd-126] , Sodium Chloride 6% Eye Ointment Usp [Nrd-127] , Gatifloxacin 0.3% Eye Drop [Nrd-129] , Clomipramine Ip 25 Mg Capsule / Tablet Ip [Nrd-19] , Haloperidol (Long Acting) 50Mg/Ml Ampoule Inj. Ip 1Ml Vial/Ampoule [Nrd-251] , Levosulpride 12.5 Mg/Ml Injection 2Ml [Nrd-274] , Risperidone Prolonged Released Depot/Suspension 25 Mg Injection [Nrd-353] , Risperidone Prolonged Released Depot/Suspension 50 Mg Injection [Nrd-354] , Triclofos Oral Suspension500 Mg/ 5Ml In 30Ml Syrup I.P. [Nrd-522] , Amisulpride 50 Mg Tab. I.P. [Nrd-548] , Aripiprazole 10 Mg Tab. I.P. [Nrd-551] , Aripiprazole 5 Mg Tab. I.P. [Nrd-552] , Chlordiazepoxide 25 Mg Tab. I.P. [Nrd-574] , Clonazepam 0.25 Tab. I.P. [Nrd-585] , Clonazepam 1Mg Tab. I.P. [Nrd-586] , Clozapine 25 Mg Tab. I.P. [Nrd-587] , Clozapine 50 Mg Tab. I.P. [Nrd-588] , Clozapine 100 Mg Tab. I.P. [Nrd-589] , Desvenlafaxine 50Mg Cr/Pr/Sr/Er Tablet [Nrd-604] , Duloxetine Gastro Resistant 20 Mg Tab. I.P. [Nrd-614] , Duloxitine Gastro Resistant30 Mg Tab. I.P. [Nrd-615] , Etizolam 0.5 Mg Tab. I.P. [Nrd-629] , Fluvoxamine 100 Mg Tab. I.P. [Nrd-639] , Fluvoxamine 50 Mg Tab. I.P. [Nrd-640] , Mirtazapine 7.5Mg Tab. I.P. [Nrd-689] , Mirtazapine 15Mg Tab. I.P. [Nrd-690] , Nitrazepam 5Mg Tab. I.P. [Nrd-714] , Nitrazepam 10 Mg Tab. I.P. [Nrd-715] , Oxazepam 15Mg Tab. I.P. [Nrd-723] , Paroxetine 12.5 Mg Control Release / Prolonged Release Tablet [Nrd-727] , Paroxetine 25 Mg Control Release / Prolonged Release Tablet [Nrd-728] , Zolpidem 10Mg Tab. I.P. [Nrd-819] , Trypan Blue 0.06% W/V Injection [Nrd-393] , Sodium Chloride 3% 100Ml Inj. Ip [Nrd-145] , Normal Saline 500 Ml Glass Bottle Injection [Nrd-315] , Normal Saline 1000 Ml Glass Bottle Injection [Nrd-316] , Anti Oxidants (Beta Carotene 10 Mg,Vit E 25Mg,Vit C 100 Mg,Copper 1.5 Mg,Managanese 1.5 Mg,Zinc 7.5 Mg,Selenium 150 Microgram) Cap. [Nrd-11] , Calcium Dobesilate 500Mg Cap. [Nrd-14] , Vitamin A 25000 Iu Cap. Ip [Nrd-38] , Ferrous Ascorbate And Folic Acid Drops 15Ml (Each Ml Contains Ferrous Ascorbate 10Mg And Folic Acid 100Mcg) [Nrd-81] , Vitamin ? E 50Mg/Ml Drops 15Ml [Nrd-83] , Vitamin D3 400Iu/Ml Drop [Nrd-84] , Vitamin D3 800Iu/Ml Drop [Nrd-85] , Folic Acid And Methylcobalamine 10 Ml Pack Injection [Nrd-241] , Vitamin D3 (600000 Iu) Inj. Ip [Nrd-402] , L Arginine 3Gm And Proanthocynadine 75Mg Granules [Nrd-465] , Calcium Phosphate 200 Ml Syrup (Each 10Ml Contain Elemental Calcium 300Mg Elemental Phosphorus 150Mg Elemental Magnesium 75Mg Elemental Zinc 4Mg Vitamin D3 200 300Iu.) [Nrd-481] , Levo Carnitine 500Mg/5Ml In 30 Ml Syrup Usp [Nrd-501] , Zinc Oral Syrup / Solution / Suspension 20 Mg / 5Ml [Nrd-524] , Zinc 50Mg Tab. [Nrd-818] , Braided E Caprolactone Coated Lactomer 1, 90Cm Gs-25,37-40Mm1/2 Circle Taper Point [Nrr-1] , Braided E Caprolactone Coated Lactomer 2-0 90Cm Gs-25,3Omm1/2 Circle Taper Point [Nrr-2] , Braided E Caprolactone Coated Lactomer 1 90Cm Gs-25,37-40Mm1/2 Circle Reverse Cutting [Nrr-3] , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Taper Point, 90 Cm [Nrr-4] , Braided E-Caprolactone Coated Lactomer 3-0 75Cm C-14 , Undyed 24Mm 3/8 Circle Reverse Cutting [Nrr-5] , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,30Mm Needle, Size 2-0, 1/2 Circle Taper Point, 90 Cm [Nrr-6] , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,40Mm Needle, Size 1, 1/2 Circle Reverse Cutting Os Needle, 90 Cm [Nrr-7] , Braided E-Caprolactone Coated Lactomer 0 90Cm Gs-24 , Violet 40Mm 1/2 Circle Taper Point [Nrr-8] , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per Usp Specifition, Purest Form Of Triclosan,20Mm Needle, Size 3-0, 1/2 Circle Taper Point, 70 Cm [Nrr-9] , Braided E-Caprolactone Coated Lactomer 1-0 90Cm Gs-25 , Undyed 37-40Mm 1/2 Circle Reverse Cutting [Nrr-10] , Polyglactin 910 Violet Braided, 1, 35 Cm 1/2 Circle Reverse Cutting (Heavy) 23 Mm -25 Mm Needle [Nrr-11] , Polyglactin 5-0 Rb Oval ½ Circle 16 Mm 45 Cm [Nrr-12] , Polyglactin 5-0 Cc 3/8 Circle 16 Mm 45 Cm [Nrr-13] , Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure Mp, Purest Form Of Triclosan, 26Mm Needle, Size 2-0, 3/8 Circle Cutting, 90 Cm [Nrr-15] , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydiaxanone Violet 1/2 Circle Round Bodied 30 Mm Needle, Length 70Cm Size 3-0 [Nrr-16] , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydiaxanone Violet 1/2 Circle Round Bodied 30 Mm Needle, Length 70Cm Size 4-0 [Nrr-17] , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 1/2 Circle Taper Point Rb-2, Double Needle, 13 Mm Needle, Length 70Cm Size 5-0 [Nrr-18] , Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 3/8 Circle Taper Point, Bb Sgle Armed Needle 17 Mm Needle, Length 70Cm Size 5-0 [Nrr-19] , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 6-0 Rb 17 Mm Needle Length 90 Cm [Nrr-22] , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 6-0 Rb 11 Mm Needle Length 90 Cm [Nrr-23] , Absorbable Surgical Suture Sterilized Surgical Double Armed Needled Suture Monofilament Polydiaxanone Violet 5-0 Rb 11 Mm Needle Length 90 Cm [Nrr-24] , Absorbable Surgical Suture Sterilized Surgical Single Armed Needled Suture Monofilament Polydiaxanone Violet 5-0 Rb 17 Mm Needle Length 90 Cm [Nrr-25] , Monofilament Polyglyconate 1 150Cm Gs-25 Loop, Green 48Mm 1/2 Circle Taper Point [Nrr-26] , Monofilament Polyglyconate 2-0, 75Cm Green 26-30Mm 1/2 Circle Taper Point [Nrr-27] , Monofilament Polyglyconate 3-0, 75Cm Green 20-26Mm 1/2 Circle Taper Point [Nrr-28] , Monofilament Polyglyconate 4-0, 75Cm Green 17-20Mm 1/2 Circle Taper Point [Nrr-29] , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 3-0,70 Cm,1/2 Circle R.B.,20 Mm [Nrr-30] , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 4-0,70 Cm,1/2 Circle R.B.,20 Mm [Nrr-31] , Monofilament Synthetic Absorbable Suture Polydioxanone - Violet Ep 5-0,70 Cm,1/2 Circle R.B.,13 Mm [Nrr-32] , Monofilament Glycomer 1 90Cm Gs-21 , Volet 37Mm 1/2 Crcle Taper Pont [Nrr-33] , Monofilament Glycomer 2-0 90Cm Gs-21 , Volet 37Mm 1/2 Crcle Taper Pont [Nrr-34] , Non Absorbable Surgical Suture, Sterilized Surical Needled Black Braided Silk With Needle 1/2 Circle Round Bodied 30 Mm Needle , Length 70 Cm Size 2-0 [Nrr-35] , Braided Coated Non Absorbable Suture Usp 1-0 75 Cm X 2 [Nrr-36] , Braided Coated Non Absorbable Suture Usp 2-0 75 Cm X 2 [Nrr-37] , Braided Coated Non Absorbable Suture Usp 3-0 75 Cm X 2 [Nrr-38] , Silk Reel 4-0 [Nrr-39] , Braided Polyester Caoted With Silicon 2, 26Mm 1/2 Circle Rc 75Cm [Nrr-44] , Braided Polyester Caoted With Silicon 5, 55Mm 1/2 Circle Rc 75Cm [Nrr-45] , Polypropylene Blue Monofilament, 2-0, 90 Cm 1/2 Circle Round Body Double Needle 26 Mm [Nrr-54] , Polypropylene Blue Monofilament Usp 3/0,2,90 Cm,1/2 Circle Taper Point (Double Armed),26 Mm [Nrr-55] , Polypropylene Blue Monofilament, 4-0, 75 Cm 1/2 Circle Round Body Double Needle 17 Mm [Nrr-56] , Polypropylene Blue Monofilament Usp 5/0,1,90 Cm,1/2 Circle Taper Point (Double Armed),18 Mm [Nrr-57] , Polypropylene Blue Monofilament, 6-0, 75 Cm 3/8 Circle Round Body (380 Microns) Double Needle (Cutting) 13 Mm [Nrr-58] , Non Absorbable Polypropylene Surgical Sutures Size:7-0,3/8 Circle C1 Taper Point Cv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,8 Mm,60 Cm [Nrr-59] , Monofilament Polybuetester Coated With Polytribiolate 6-0 75Cm 2Xcv-1X36 , Blue 9Mm 3/8 Circle Taper Point [Nrr-60] , Monofilament Polybuetester Coated With Polytribiolate 4-0 90Cm 2Xcv-23X36 , Blue 17Mm 1/2 Circle Taper Point [Nrr-61] , Monofilament Polybuetester Coated With Polytribiolate 7-0 60Cm 2Xmv-175-8 , Blue 8Mm 3/8 Circle Taper Point [Nrr-62] , Monofilament Polybuetester Coated With Polytribiolate 2-0 90Cm 2Xv-20X36 , Blue 26Mm 1/2 Circle Taper Point [Nrr-63] , Monofilament Polybuetester Coated With Polytribiolate 3-0 90Cm 2Xv-20X36 , Blue 26Mm 1/2 Circle Taper Point [Nrr-64] , Non-Absorbable Synthetic Unidrectional Dual Cut Angle Barb With Welded Loop Or Tab End Made Up With Polybeutester Size 1, 37Mm, 30Cm, 1/2 Circle, Tp [Nrr-65] , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polybeutester Blue Size 2-0, 1/2 Circle, 37Mm, 30Cm Tp, [Nrr-66] , Absorbable Synthetic Unidirectional Dual Cut Angle Barbed With Welded Loop Or Tab End Made Up With Polyglyconate 2-0 26-30 Mm 30 Cm 1/2 Circle Taper Point [Nrr-67] , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 1-0, 1/2 Circle, 37Mm, 30Cm Tp [Nrr-68] , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 2-0, 1/2 Circle, 26Mm, 30Cm Tp [Nrr-69] , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 3-0, 1/2 Circle, 26Mm, 30Cm Tp [Nrr-70] , Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop On End Madeup With Glycomer Blue Size 2-0, 1/2 Circle, 24Mm, 30-45Cm Rc [Nrr-71] , Laproscopic Knotless Pga -Pcl Surgical Suture Self Fixation Device With Autolock Mechanism Made Up Of Pga -Pcl Unidirectional Taper Point 26 Mm & 20 Cm Size 2-0 [Nrr-72] , Polyester Ethylene Terephthalate Nonabsorbable Surgical Braided, Sterile, Surgical Suture Composed Of Poly (Ethylene Terephthalate.) Long-Chain, Linear Polyesters 1 /2 Circle Tapercut 2 X V-5 Double Needle 26 Mm 90 Cm Green Color Size 2-0 [Nrr-73] , Laproscopic Knotless Pga -Pcl Bidirectional Taper Point Surgical Suture Self Fixation Device With Autolock Mechanism Made Up Of Pga -Pcl Bidirectional Taper Point 17 Mm & 32Cm [Nrr-74] , Absorbable Antibacterial Polydiaxonone Monofilament Taper Point Surgical Suture Absorbable Antibacterial Suture Made Up Of Polydiaxonone Coated With Triclosan Voilet Monofilament 1/2 Circle Taper Point Ct-1 40 Mm Needle 90 Cm Suture Size 1 [Nrr-75] , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 1-0,90 Cm,1/2 Circle R.B.,30 Mm [Nrr-79] , Non-Absorbable Surgical Suture Black Braided Silk 1-0 Rc 3/8 Circle 45 Mm 76 Cm [Nrr-80] , Non-Absorbable Surgical Suture Black Braided Silk 5-0 Rc 3/8 Circle 12 Mm 76 Cm [Nrr-81] , Braided Coated Non Absorbable Suture Natural Silk - Black Dyed Usp 5-0,76 Cm,3/8 Circle R.B,12 Mm [Nrr-82] , Non-Absorbable Surgical Suture Black Braided Silk 6-0 Rc Mp 3/8 Circle 8 Mm [Nrr-83] , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 2-0, 1/2 Circle Taperpoint, 36 Mm,100 Cm [Nrr-85] , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 6-0 Rb Micro Point ¼ Circle 8 Mm 45 Cm 2670 [Nrr-86] , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 4-0 Cc 3/8 Circle 16 Mm 45 Cm 2442 [Nrr-87] , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 3-0 Cc 3/8 Circle 16 Mm 45 Cm 2442 [Nrr-88] , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 5-0 Cc 3/8 Circle 16 Mm 45 Cm 2442 [Nrr-90] , Absorbable Surgical Suture (Synthetic )Coated Polyglactin/Pga 910 Voilet 5-0 Rb Oval 1/2 Circle 16 Mm 45 Cm [Nrr-91] , Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 26Mm Length 70Cm3-0 [Nrr-95] , Non Absorbable Surgical Suture Sterilized Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm4-0 [Nrr-96] , Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16Mm Length 70Cm 5-0 [Nrr-97] , Non Absorbable Polypropylene Surgical Sutures Size:6-0,3/8 Circle 175-6 Taper Point /Rc Bv Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm 13 Mm [Nrr-98] , Non Absorbable Polypropylene Surgical Sutures Size:7-0,Compound Curve ( 1/2 & 3/8 Circle) Circle 175-6 Taper Point Blackmatte Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm [Nrr-99] , Monofilament Synthetic Absorbable Suture Poliglecaprone 25 - Undyed Ep 3-0,70 Cm,1/2 Circle Oval R.B. J.B. Needle,26 Mm [Nrr-100] , Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 3-0, 3/8 Circle Reverse Cutting,Ps Prime 24 Mm,75 Cm [Nrr-103] , Nonabsorbable Polypropylene Light Weight Macroporous Mesh [Nrs-1] , Three Dimensional Monofilament Polyester Marking Size 15 Cm Circular [Nrs-2] , Three Dimensional Monofilament Polyester Marking Size 20X15 Cm Circular [Nrs-4] , Absorbable 5 Mm Hernia Mesh Fixation Device 30 Screw Shaped [Nrs-5] , Absorbable 5 Mm Hernia Mesh Fixation Device 15 Screw Shaped [Nrs-6] , Non Absorbable 5Mm Hernia Mesh Fixation Device With 30 Helical Shaped Titanium Tacks 3.96Mm Width And 0.61Mm Diameter [Nrs-7] , Light Weight Monofilament Polypropylene Mesh Size Large Left 10.8*16Cm /15*10 Cm [Nrs-10] , Light Weight Monofilament Polypropylene Mesh Size Large Right 10.8*16Cm /15*10 Cm [Nrs-11] , Light Weight Monofilament Polypropylene Mesh Size Extra Large Left 12.4Cm * 17.3 /16*12 Cm [Nrs-12] , Light Weight Monofilament Polypropylene Mesh Size Extra Large Right 12.4Cm * 17.3/16*12 Cm [Nrs-13] , Linear Cutter 55Mm With Six Rows [Nrs-15] , Linear Cutter 75Mm With Six Rows [Nrs-16] , Universal Linear Cutter Cartridge 75Mm [Nrs-17] , Universal Linear Cutter Cartridge 55Mm [Nrs-18] , Curved Cutter Stapler 40 Mm Linear Cutter (Detail In Rc) [Nrs-19] , Curved Green Cartridge Having Close Staple Height Of 2.0 Mm(Detail In Rc) [Nrs-20] , Circular Stapler 33Mm (Detail In Rc) [Nrs-23] , Laparoscopic Cartridge For Stapler 60 Mm Blue, 1.5 Mm [Nrs-24] , Laparoscopic Cartridge For Stapler 60 Mm Green, 2.0 Mm [Nrs-25] , Hemorrhoidal Stapler Kit Consists Of 33Mm [Nrs-26] , Optically Guided Bladeless Trocar 12Mm Length 150Mm [Nrs-27] , Optically Guided Bladeless Trocar 12Mm Length 100Mm [Nrs-28] , Facial Closure Device Contain - Optical Bladeless Trocar With Facial Closure Device Comaptible With Clear Cannula Have Two Side Opening Meant For Uniform Port Closure [Nrs-29] , Varied Staple Height Reloads/Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology (Detail In Rc) [Nrs-30] , Varied Staple Height Reloads/Cartridges For 80 Mm Gia [Nrs-31] , Linear Cutter With Varied Staple Height Tri-Staple Gia 60 Mm [Nrs-32] , Eea Circular Stapler Purple Colour Medium Thick [Nrs-33] , Linear Cutter With Varied Staple Height Tri-Staple Gia 80 Mm [Nrs-34] , Wound Protector Medium 5-9 Cm [Nrs-36] , Endo Catch Specimen Removal Kit With 34.5Cm Shaft Length [Nrs-38] , Disposable Laparoscopic Clip Applier With 16 Clips, 5Mm Diameter [Nrs-39] , Laparoscopic Liner Cutter With Cartridges In Sizes Of 45Mm (Detail In Rc) [Nrs-41] , Laparoscopic Liner Cutter With Cartridges In Sizes Of 60Mm [Nrs-42] , Hand Activated Curved Taper Tip Coagulating Shears Compatible Focus 9 [Nrs-43] , Hand Activated Curved Taper Tip Coagulating Shears Compatible Focus 17 [Nrs-44] , Advance Bipolar Hand Activated Probe With 5Mm Shaft Diameter And 35 Cm Shaft Length With 5 Mm Wide [Nrs-45] , Advanced Bipolar Tissue Sealer 37 Cms, With 5Mm Shaft Diameter, 24 Mm Jaw Length, 21.8 Mm Cut Length And 13.4 Mm [Nrs-50] , Laparoscopic Shears 5Mm Diameter,36Cm Long, 18Mm Curved Coated Blade (Detail In Rc) [Nrs-52] , Connecting Cable For Ultrasonic Harmonic Scalpel For Open Energy With Focus Plus Shear- Hp Blue [Nrs-53] , Connecting Cable For Ultrasonic Harmonic Scalpel For Lap Energy With Ace Plus Shear Hp054 [Nrs-54] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Plates - 2 Mm Thickness (2*2 ) Hole [Nrs-57] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Plates - 2 Mm Thickness (1*2 ) Hole [Nrs-58] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Plates - 2 Mm Thickness (1*1 ) Hole [Nrs-59] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Screw- (2 Mm ) [Nrs-60] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Screw- (1.5 Mm ) [Nrs-61] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Screw- (2.5 Mm ) [Nrs-62] , Platting For Maxillary Swing And Mandibular Fixation Surgeries Screw- (3 Mm ) [Nrs-63] , Speech Prosthesis For Laryngectomy 22.5Fr (6 Mm) [Nrs-74] , Speech Prosthesis For Laryngectomy 22.5Fr (8 Mm) [Nrs-75] , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 2.0,2.5 And 3.0 Mm [Nrs-81] , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 3.0,3.5 And 4.0 Mm [Nrs-82] , Varied Staple Height Reloads/Cartridges For 60 Mm Gia [Nrs-83] , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 2*4Cm Or Size 2-3*5-6Cm [Nrs-85] , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 5*10Cm Or Size 5-7*7-11Cm Or 4*8Cm [Nrs-86] , Disposable 10 Mm Endoscopic Clip Applier Medium/Large Size [Nrs-87] , Disposable Clip Applier Preloaded With 20 Clips Medium [Nrs-92] , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) 8 No [Nrs-98] , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) 10 No [Nrs-99] , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) No. 14 [Nrs-100] , Close Wound Drainage Device Under Negative Pressure (Closed Wound Suction Unit) No. 12 [Nrs-101] , Urine Collecting Bag, Disposable 2000 Ml With Uroflow Meter [Nrs-103] , Central Neck Line ? Double Lumen (Antimicrobial Coated/ Chlorhexidine , Silver Sulfadiazine Coated) Central Lumen Catheter, Double Lumen) 7 Fr (Detail In Rc) [Nrs-104] , Microcatheter Selective Infusion Microcatheters For Intra Cranial Aneurysm Treatment With 2 Tip Markers [Nrs-105] , Microcatheter Selective Infusion Microcatheters For Deploying Intracranial Device: Stent Deployment [Nrs-106] , Microcatheter Selective Infusion Microcatheters For Flow Diverter Delivery With Single Tip Markers 0.027Inch [Nrs-107] , Microcatheter Flow Dependent Super-Selective High Flow Infusion Microcatheters For Cerebral/Spinal Avms (Compatible With Dmso) [Nrs-108] , Micro Guide Wire For Microcatheter Shapable Distal End And With Torque 0.014Inch [Nrs-109] , Aortic Punch 4 [Nrs-117] , Aortic Punch 4.5 [Nrs-118] , Aortic Punch 3.6 [Nrs-121] , Laproscopic Port With Trocar 150Mm Length [Nrs-124] , Biopsy Gun With Compitible Co-Axial Needle 14Gx11cm [Nrs-128] , Biopsy Gun With Compitible Co-Axial Needle 18Gx11cm [Nrs-134] , Biopsy Gun With Compitible Co-Axial Needle 18Gx15cm [Nrs-135] , Patient Pre Operative Skin Prepration Solution 25-35Ml [Nrs-140] , Rem (Return Electrode Monitoring) Single Use (Detail In Rc) [Nrs-141] , Surgical Gloves 6.5 Puncture Indicator Technology [Nrs-144] , Surgical Gloves 7 Puncture Indicator Technology [Nrs-145] , Surgical Gloves 7.5 Puncture Indicator Technology [Nrs-146] , Ionic Silver Dressings For Low To High Exuding Wounds 10 Cms X 10 Cms [Nrs-148] , Self Adherent Moist Wound Dressing 16Cmx20cm Approximate [Nrs-149] , Double Wall Resuscitator With Peep Valve In Adult [Nrs-151] , Double Wall Resuscitator With Peep Valve In Paediatrics [Nrs-152] , Single Patient Use Sebs Resuscitator Volume 220Ml(Spur Ii With Peep Valve In Neonatal) [Nrs-155] , Pre-Formed Sga With Gastric Access & Intubation Sizes ? 3 [Nrs-160] , Pre-Formed Sga With Gastric Access & Intubation Size 4 [Nrs-161] , Silicone Pre-Formed Sga Size 2 [Nrs-166] , Silicone Pre-Formed Sga Size 3 [Nrs-168] , Silicone Pre-Formed Sga Size 4 [Nrs-169] , Offset Connector Cardio Sensor Electrodes Sizes ?Adult [Nrs-174] , Disposable Sga Anatomical Curve Size 3 [Nrs-188] , Disposable Sga Anatomical Curve Size 4 [Nrs-189] , Ultrasorbs Ap Disposable Drypads For Moisture Management 58.4X90cm (Detail In Rc) [Nrs-194] , Over-The-Ear Nasal Cannula 50 Cm Tubing [Nrs-196] , Pediatric Nasal Cannula 7 Cm Star-Lumen Tubing [Nrs-197] , Volumetric Incentive Spirometer (Adult) 4000 Ml And Above With Handle (Detail In Rc) [Nrs-199] , Volumetric Incentive Spirometer (Pediatric) 2500 Ml With Handle (Detail In Rc) [Nrs-200] , Adult Mask For Tracheostomy [Nrs-202] , Pardiatric Mask For Tracheostomy [Nrs-203] , Elongated Aerosol Mask Adult [Nrs-204] , Adult Conventional Single Water Trap (Non Heated) [Nrs-207A] , Adult Conventional Single Water Trap (Heated) [Nrs-207B] , Adult Ventilator Circuit Single Limb Portable [Nrs-208] , Adult Ventilator Circuit Single Water Trap [Nrs-209] , Infant Prong Cpap Cannula [Nrs-211] , Fhme Heat And Moisture Exchangers With Bacteria Viral Filters [Nrs-212] , Tracheostomy Hme [Nrs-213] , Double Lumen Endobronchial Tube Left: Size-37Fr [Nrs-217] , Double Lumen Endobronchial Tube Left: Size-39Fr [Nrs-218] , Manifold Manifolds In 2, 3, 5 Port [Nrs-231] , High Pressure Tubing In 25Cm With Braided Flexible Tubing Of Polyurethane Rated 1200 Psi Usfda Approved [Nrs-232] , High Pressure Tubing In 51Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda Approved [Nrs-233] , High Pressure Tubing In 76,Cm With Braided Flexible Tubing Of Polyurethane Rated 1200 Psi Usfda Approved [Nrs-234] , High Pressure Tubing In 122,Cm With Braided Flexible Tubing Of Polyurethane Rated 1200 Psi Usfda Approved [Nrs-235] , High Pressure Tubing In 183Cm With Braided Flexible Tubing Of Polyurethane Rated 1200 Psi Usfda Approved [Nrs-236] , Torque Device For .014 To .038 Standard And Hydrophilic Guide Wires With Squeeze-Load-Release Mechanism [Nrs-237] , Radial Band Radial Hemostatis Band In 24 Cm [Nrs-238] , Radial Band Radial Hemostatis Band In 29 Cm [Nrs-239] , Angiography Needle 18G [Nrs-240] , Angiography Needle 20G [Nrs-242] , Angiography Wire Ptfe Guidewire In 0.035,0.038 In Regular Length [Nrs-244] , Angiography Wire Long Length Ptfe Guidewire In .035, .038, With Exchange Length (Detail In Rc) [Nrs-245] , Hydrophilic Wire Long Length Hydrophilic Guidewire Of 0.018,0.025,0.035,0.038 Inch In 180Cm Length [Nrs-248A] , Hydrophilic Wire Long Length Hydrophilic Guidewire Of .018, .025, .035, .038 In 220Cm Length [Nrs-248B] , Hydrophillic Braided Sheath 4F To 7F [Nrs-249] , Femoral Sheath With Needle 5F To 8F [Nrs-250] , Angiography Catheter 4F-6F [Nrs-251] , Angiography Radial Catheters 4-6F [Nrs-252] , One Loop And Triple Loop Snare Kit(2-35Mm Diameter, 90-Degree Nitinol And Gold-Plated Tungsten Loop) And Multiloop Snare Kit(2-45Mm Diameter Three Interlaced Nitinol Loops) For Foreign Body Retrieval [Nrs-253] , Null , Closed Suction Catheter For Paediatrics 5Fr [Nrs-255] , Closed Suction Catheter For Paediatrics 6Fr [Nrs-256] , Closed Suction Catheter For Paediatrics 7Fr [Nrs-257] , Closed Suction Catheter For Paediatrics 8Fr [Nrs-258] , Closed Suction Catheter For Paediatrics 10Fr [Nrs-259] , Closed Suction Catheter For Paediatrics 12Fr [Nrs-260] , Paediatric Endotracheal Tube Size 3Mm [Nrs-261] , Paediatric Endotracheal Tube Size 3.5Mm [Nrs-262] , Paediatric Endotracheal Tube Size 5.5Mm [Nrs-263] , Kimvent Bal Cath 13Fr [Nrs-266] , Kimvent Bal Cath 16Fr [Nrs-267] , Catheter Mount Double Swivel Connector With Bronchoscopy Port Approved By Us Fda [Nrs-269] , Gastrostomy Feeding Tube Size ? 20 [Nrs-274] , Gastrostomy Feeding Tube Size ? 24 [Nrs-275] , Percutaneous Endoscopic Gastrostomy (Peg) 24Fr [Nrs-278] , Anti Microbial Gloves 6 Inches [Nrs-308.A] , Anti Microbial Gloves 6.5 Inches [Nrs-308.B] , Anti Microbial Gloves 7 Inches [Nrs-308.C] , Anti Microbial Gloves 7.5 Inches [Nrs-308.D] , Anti Microbial Gloves 8 Inches [Nrs-308.E] , Anterior Chamber Iol Pmma Material Single Piece Kelman Multiflex Design 5-6 Mm Optic Size With 12-13Mm Overall Size Biconvex Power Range 12 To 24 [Nrs-309] , Capsular Tension Ring Standard Pmma Material With One Eyelet Each At Each End 10 To 12 Mm Overall Diameter Sterile [Nrs-310] , Neonatal High Flow Nasal Cannula Having 8 Litre Flow With Soft Tip [Nrs-326] , Pur-Xro Catheter 20Cm 28G/1Fr Picc Line With Stylet (Detail In Rc) [Nrs-327] , Pur-Xro Catheter 30 Cm 24G/2Fr Picc Line With Split Cannula (Detail In Rc) [Nrs-328] , Long Introducer Sheath (20-30 Cm Long) (Size 5Fr.) [Nrs-334] , Long Introducer Sheath (20-30 Cm Long) (Size 6Fr.) [Nrs-335] , Long Introducer Sheath (20-30 Cm Long) (Size 7Fr.) [Nrs-336] , Trans Radial Introducer Sheeths 4F [Nrs-341] , Trans Radial Introducer Sheeths 5F [Nrs-342] , Trans Radial Introducer Sheeths 6F [Nrs-343] , Long Introducer Sheath Dedicated For Transradial Access Size 5Fr [Nrs-368] , Long Introducer Sheath Dedicated For Transradial Access Size 6Fr [Nrs-369] , Long Introducer Sheath Dedicated For Transradial Access Size 7Fr [Nrs-370] , Ptfe Coated Diagnostic Guide Wire (Exchange Length, Regular Stiffness) 0.035Inches [Nrs-381] , Hydrophilic Diagnostic Guide Wire ? Radifocus Tarumo Type (Regular Length, Regular Stiffness) 0.032 Inches [Nrs-387] , Hydrophilic Diagnostic Guide Wire ? Radifocus Tarumo Type (Regular Length, Regular Stiffness) 0.035Inches [Nrs-388] , Radiofocus Miniplastic Guidewire (Regular Stiffness) 0.035Inches [Nrs-392] , Judkins Catheter (Jr) 5Fr [Nrs-398] , Judkins Catheter (Jr) 6Fr [Nrs-399] , Judkins Catheter (Jr) 7Fr [Nrs-400] , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved 5Fr [Nrs-403] , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved 6Fr [Nrs-404] , Judkins Catheter (Jl) Us Fda + Ce/ Dgci Approved 7Fr [Nrs-405] , Judkins Catheter Pigtail 5 French Us Fda And Ce/ Dgci Approved Left And Right Judkins Catheters In Various Standard Curves And Lengths [Nrs-408] , Judkins Catheter Pigtail 6 French Us Fda And Ce/ Dgci Approved Left And Right Judkins Catheters In Various Standard Curves And Lengths [Nrs-409] , Judkins Catheter Pigtail 7 French Us Fda And Ce/ Dgci Approved Left And Right Judkins Catheters In Various Standard Curves And Lengths [Nrs-410] , Multipurpose Catheter 5 French Us Fda And Ce/ Dgci Approved Multipurpose Catheters In Various Standard Curves And Lengths [Nrs-413] , Amplatz Catheter Amplatz Left (Al) 5Fr [Nrs-418] , Amplatz Catheter Amplatz Left (Al) 6Fr [Nrs-419] , Amplatz Catheter Amplatz Left (Al) 7Fr [Nrs-420] , Amplatz Catheter Amplatz Right (Ar) 5Fr [Nrs-423] , Amplatz Catheter Amplatz Right (Ar) 6Fr [Nrs-424] , Amplatz Catheter Amplatz Right (Ar) 7Fr [Nrs-425] , Nternal Mammary Catheter 5Fr [Nrs-428] , Nternal Mammary Catheter 6Fr [Nrs-429] , Nternal Mammary Catheter 7Fr [Nrs-430] , By-Pass Graft Catheter 5Fr [Nrs-433] , By-Pass Graft Catheter 6Fr [Nrs-434] , By-Pass Graft Catheter 7Fr [Nrs-435] , Transradial Diagnostic Coronary Catheter Tiger Type 5Fr [Nrs-438] , Introducer Sheaths For Pediatric Use (Size 5 Fr. [Nrs-453] , Arterial Pressure Monitor Lines (100 Cm Long) [Nrs-478] , Arterial Pressure Monitor Lines (150 Cm Long) [Nrs-479] , Arterial Pressure Monitor Lines (200 Cm Long) [Nrs-480] , Angio.Kit/Ptca Kit (3 Port Many Fold With Attached Tubing One Pressure Line + Two Iv Set Connecting Tube And Two Leurlock Syringe ) [Nrs-501] , Venaseal Closure System For Varicose Veins N Butyl Based Adhesive Formation 50/90/105/120Cm 145Cm(3/4/6/8 F ,014/0.35Inch Compatible [Nrs-515] , Bone Marrow Biopsy Needle 8G 4? & 6? [Nrs-532] , Silicone Foleys Catheter Sizes - 12Fr [Nrs-537] , Silicone Foleys Catheter Sizes - 14Fr [Nrs-538] , Silicone Foleys Catheter Sizes - 16Fr [Nrs-539] , Silicone Foleys Catheter Sizes - 18Fr [Nrs-540] , Cutting & Coagulations Device With With Wide Jaw Aperture 13Mm And Cut Length 18.5Mm With Shaft Rotation Of 350 Degrees And With One Step Sealing Mechanism. [Nrs-542] , Cutting &Coagulations Device With With Cut Length Of 14.7 Mm, Seal Length Of 16.5Mm, Jaw Angle 28 Degrees. [Nrs-543] , Cutting And Coagulations Device With Tissue Fusion Ligature Technology Laparoscopic Blunt Tipped Vessel Sealer And Divider 37 Cm Long 5Mm Instrument(Deatail In Rc) [Nrs-544] , Cutting &Coagulations Device With Tissue Fusion Ligasure Technology Instrument For Open Surgeries With Instrument Length Between 21-23Cm (Detail In Rc) [Nrs-545] , Cutting And Coagulations Device With Tissue Fusion Ligasure Technology Have36mm Jaw Length, 180 Degree Rotatable Instrument With Curved Blade For Large Volume Tissue. Should Have The Manual Cutting Mechanism. [Nrs-546] , Cutting &Coagulations Device With Tissue Fusion Ligasuretechnology Have Vessel Sealing Instrument For Open Surgeries [Nrs-547] , Double Lumen Catheter Size- 12 Frx16 Cm [Nrs-552] , Double Lumen Catheter Size- 12 Frx13 Cm [Nrs-553] , Long Term Double Lumen Dialysis Catheter Size- 14.5 Frx23 Cm [Nrs-555] , Long Term Double Lumen Dialysis Catheter Size- 15 Fr X 19 Cm [Nrs-556] , Long Term Double Lumen Dialysis Catheter Size 15 Fr X 23 Cm [Nrs-557] , Transperant Surgical Wound Dressing Size- 5Cm X 5.72Cm [Nrs-558] , Transperant Surgical Wound Dressing Size- 10X15 [Nrs-559] , Transperant Surgical Wound Dressing Size- 10X30 [Nrs-561] , Transperant Surgical Wound Dressing With A Dimensional Hydrocellular Pad Microbicidle Protection And Anti Microbial Property Size 10X40 [Nrs-562] , Multi-Vent Mask Pediatric, [Nrs-564] , Closed Suction Catheter Mdi Port 12 Fr. [Nrs-566] , Closed Suction Catheter Mdi Port 14 Fr. [Nrs-567] , Closed Suction Catheter Has Isolated Turbo Cleaning Chamber 12 Fr. [Nrs-568] , Closed Suction Catheter Has Isolated Turbo Cleaning Chamber14 Fr. [Nrs-569] , Multifocal Iol Biconvex, Single Piece Optic Size 6 Mm, Overall 12-13 Mm Single Or Double Loop Uv Blocking 360 Degrees Square Edge Sterile Injector For Sub 2.8 Mm Incision Power Plus16 To Plus25 D Diffractive Multifocal Design(Deatil In Rc) [Nrs-571] , Glaucoma Drainage Implant (Valved) With Silicon Tube Adult 184Mm Square [Nrs-572] , Glaucoma Drainage Implant (Valved) With Silicon Tube Paediatric 96Mm Square [Nrs-573] , Scleral Fixiated Intraoccular Lense Single Piece Pmma Optic6-6.5Mm Overall13.5Mm Haptic With Hole For Suture Fixation [Nrs-586] , Central Line Triple Lumen With Y Needle And Nitinol Guide Wire 7Fr To 8.5 Fr With 15Cm To 20Cm Catheter With Tecoflex/Polyurathane Material [Nrs-593] , Post Operative Surgical Cover Dressings Hydrofiber Dressings With 1.2% W/W Impregnated Ionic Silver And Tripple Hydrocolloid Matrix Dressings With Broad Spectrum Bactricidal Efficacy With Gel Forming Technology [Nrs-602] , Post Operative Surgical Cover Hydrofiber Dressings 20X50 Cm (Detail In Rc) [Nrs-603] , 2 Pcs Flat Base Ostomy Body Fit 60 Mm Kit [Nrs-604] , 2 Pcs Convex Base Ostomy Body Fit 60 Mm Kit [Nrs-606] , 1 Pcs Trasnparent Colostomy Body Fit 60Mm Kit [Nrs-608] , 2 Pcs Flat Base Ostomy Body Fit Bag 60 Mm (Detail In Rc) [Nrs-609] , 2 Pcs Flat Base Ostomy Body Fit Bag 70 Mm (Detail In Rc) [Nrs-610] , 2 Pcs Convex Base Ostomy Body Fit Bag 60 Mm (Detail In Rc) [Nrs-611] , Antimicrobial Transperant Provides Immediate And Continuous Antimicrobial Protection With Integrated Chlorhexidine Gluconate (Chg) Gel Pad Size 11.5Cm To 8.5Cm [Nrs-615] , Sterile Self Adherent With Lipido Colloid Technology 13X13cm [Nrs-620] , Sterile Self Adherent With Lipido Colloid Technology 10X25cm [Nrs-625] , Polysiloxane And Silicone Gel Sheet For Scar Managment Size 10 X 10 Cm [Nrs-626A] , Polysiloxane And Silicone Gel Sheet For Scar Managment Size 5 X 5 Cm [Nrs-626B] , Triple Leyar Antimicrobal Form Dressing For Burn Wound With Silver Sulphate, Silver Content 1.2 Mg/Cm Square With Active Release Of Silver Upto 7 Days For Painless Dressing Change Size 20X20cm (45Mm)Plus/Minus15% [Nrs-627] , Triple Hydrocolloid Skin Barrier Where No Cutting 70Mm [Nrs-629] , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0 Mm , Purple Colour 8Mm [Nrs-633.A] , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge, Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0Mm , Purple Colour 10Mm [Nrs-633.B] , Nasal Haemostatic Sponge Pack With Out Airway 8Inch [Nrs-686] , Nasal Haemostatic Sponge Pack With Out Airway 10 Inch [Nrs-687] , Nasal Haemostatic Sponge Pack (With Airway) 8Inch [Nrs-688] , Flexometlic Tube 3-8.5 With Stylet Reinforce Et Tube With Wiring From Tip To End [Nrs-718] , Disposable Transducers For Invasive Pressure Monitoring· Should Be Compatible With Available System In Cath Lab (Iabp Data Scope And Cath Lab Transducer) And Iccu Should Meet Highest Medical Industrial Standards [Nrs-721] , Dialyzer Size 1.3 Sqm With Blood Tubing Set. Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Of The Same Company [Nrs-732] , Dialyzer Size 1.4 Sqm With Blood Tubing Set. Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Of The Same Company [Nrs-733] , Dialyzer Size 1.6 Sqm With Blood Tubing Set. Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Of The Same Company [Nrs-734] , Dialyzer Size 1.8 Sqm With Blood Tubing Set. Dialyzer Should Be Synthetic Membrane (Poly Sulfon/ Polyethersulfon) Blood Tubing Set Must Be Of The Same Company [Nrs-735] , Padiatric Dialyzer Size 0.6 Sqm Padiatric Dialyzer (Dialyzer Should Be Synthetic Membrane Polysulfon/Polyethersulfon) With 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector [Nrs-736] , Padiatric Dialyzer Size 0.8 Sqm Padiatric Dialyzer (Dialyzer Should Be Synthetic Membrane Polysulfon/Polyethersulfon) With 1. Blood Tubing 2. Av Fistula Needle 16G/17 G 3. Transducer Protector [Nrs-737] , Non Edl Drug , Anti-Hcv Antibody(Rapid Test)[Ne70]-[P] , Glucose Powder (Dextrose Monohydrate) Energy 300 Kcal Carbohydrate 75 Gm Of Which Sugar (Sucrose) 0.00Gm Fat And All Type Of Fatty Acids 0.00Gm Protein: 0.00Gm [Ne35]-[M] , Hand Rub(Detail In Rc)[Ne31]-[P] , Hbsag(Rapid Test)[Ne69]-[P] , Hcv Rapid Testing Kits[Nes21]-[Dh] , Hepatitis B Immunoglobulin Hbig 100 Iu[Ne68]-[Dh] , Hepatitis B Surface Antigen Elisa Testing Kit Iii Genration[Nes16]-[Dh] , Hepatitis B Surface Antigen Elisa Testing Kit Iv Genration[Nes17]-[Dh] , Hepatitis-B Surface Antigen (Rapid) Testing Kit[Nes20]-[Dh] , Hiv (Elisa) Testing Kit Iv Generation[Nes15]-[Dh] , Malaria Antigen (Rapid) Detection Test[Nes23]-[Dh] , Mma Drugs (In A Combination Pack) Blister Strip Containing 1 Tab Mifeprestone 200Mg And 4 Tab Of Misoprostol 200Mcg)[Ne17]-[P] , Multiple Urine Analysis Strip[Ne6]-[Sc] , Single Blood Bag(350Ml)[Nes8]-[Dh] , Hiv (Rapid) Testing Kit Iv Generation[Nes19]-[Dh] , B.P. Instrument Mercury , B.P. Instrument Electric , Heating Elements , Thermometer , Lapped , Glucometer With Strip , Laboratory Items , Widal Test Kit , Widal Slide Test , Rheumatoid Factor (Rf) , Aslo , Kits S Crp , Prothrombin Test , Multiparameter Urine Strip (10 Parameter) , Sodium Hypochloride 4% 5 Itr , Sodium Citrate Vial 5 Mi , Urine/ Sputum Container Plastic , Disposable Esr Pipette With Rubber Cup , Vaccutainerwithout Vaccum 5 Ml Red Cap , Vaccutainerwithoutvaccum 5 Ml Purple Cap , Vaccutainerwithout Vaccum 5 Ml Yellow Cap , Vaccutainerwithout Vaccum 2 Ml Purple Cap , Ria Vial 5 Ml Without Cap , Test Tube Plastic4” With Cap , Test Tube Glass 10 Ml , Test Tube Glass 5 Ml , Blood Transfution Set , Diamond Pencil , Field Stain A (Eosine) 500 Ml , Field Stain A (Methelene Blue) 500 Ml , Priker Lancet(Priker Needle) , Tipps- Yello , Tipps- Blue , Capillry Tube , Jsb U T , Jsb 2’ , N/10 Hcl 500 Mi , Giema- Stain25 Gm Powder , May — Grunwalds Stain Hi — Cert , Rapid Pap Stain Kit , Turk S Fluid 500 Ml , Leish Man Stain Powder 25 Gm , 1000Mi /1Itrmeasuringcylinder , 200 Ml Measuringcylinder , Conical Flask1 Itr , Beaker 1 Ltr , Filter Paper Grade 1 , Fnac Syring Holder , Tissue Paper Roll , Liquid Paraffin , Cover Slip 18Mm Squre , Cover Slip Large 24*50 Mm , D.P 500 Ml , Acetone- Ar Grade , Xyelne Ar Grade , Absente Alcohol , Methanol Ar Grade , Staining Rack For 25 Slide , Staining Rack Holder/Jar Slide , Sanitizer , Glass Slide , Kiton Strip , Sample Cup 2Ml Plastic , Soda Lime 5 Ltr
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
43.
Health and Family Welfare #9017147 Technical Bid
E-Bid For The Empanelment Of Analytical Testing Laboratories For The Test And Analysis Of Surgical & Sutures / Medical Devices Lab Empanelment Surgical And Sutures Supply And Empanelment Of Surgical And Suture Drug Item , Nonabsorbable Polypropylene Light Weight Macroporous Mesh , Absorbable 5 Mm Hernia Mesh Fixation Device 30 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4.1 Mm Length Along With Flexible Shaft Up To 3 Cm. , Absorbable 5 Mm Hernia Mesh Fixation Device 15 Screw Shaped With Proximal Wings Of Pgla Tacks Of 4.1 Mm Length Along With Flexible Shaft Up To 3 Cm. , Non Absorbable 5 Mm Hernia Mesh Fixation Device With 30 Helical Shaped Titanium Tacks 3.96Mm Width And 0.61 Mm Diameter , Linear Cutter 55Mm With Six Rows, 3D Staple Formation, Option Of Closed Staple Height Of 1.5Mm / 1.8Mm / 2Mm In One Cartridge Only , Linear Cutter 75Mm With Six Rows, 3D Staple Formation, Option Of Closed Staple Height Of 1.5Mm / 1.8Mm / 2Mm In One Cartridge Only , Universal Linear Cutter Cartridge 75Mm Open Linear Cutter Compatible With Selectable Staple Height Linear Cutter 75Mm.Option Of Closed Staple Height Of 1.5Mm / 1.8Mm / 2Mm In One Cartridge Only. 6 Rows 3-D Staple Technology. , Universal Linear Cutter Cartridge 55Mm For Open Linear Cuttercompatible With Selectable Staple Height Linear Cutter 55Mm.Option Of Closed Staple Height Of 1.5Mm / 1.8Mm / 2Mm In One Cartridge Only. 6 Rows 3-D Staple Technology. , Curved Cutter Stapler 40 Mm Linear Cutter Simultaneous Cutting And Stapling , Curved Green Cartridge Having Close Staple Height Of 2.0 Mm, Tactile Feedback On Completion Of Firing Sequence, New Anvil, Knife With Every Catridge , Laparoscopic Cartridge For Stapler 60 Mm Blue, 1.5 Mm Closed Staple Height With Gripping Surface Technology And Six Rows Compatible With All Range Ofendoscopic Linear Cutter 60Mm , Laparoscopic Cartridge For Stapler 60 Mm Green, 2.0 Mm Closed Staple Height With Gripping Surface Technology And Six Rows Compatible With All Range Of Endoscopic Linear Cutter 60Mm , Pph Stapler 33Mm - Hemorrhoidal Stapler Kit Consists Of 33Mm Hemorrhoidal Circular Stapler ( With Fixed Anvil, Adjustable Closed Staple Height From 0.75 Mm – 1.5 Mm, Staple Open Leg Length Of 5.5 Mm ) , Suture Threader, Circular Anal Dilator, Purse-String Suture Anoscope, Suture For Purse String. , Optically Guided Bladeless Trocar 12Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Optically Guided Bladeless Trocar 12 Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer Length 100Mm. , Facial Closure Device Contain - Optical Bladeless Trocar With Facial Closure Device Comaptible With Clear Cannula Have Two Side Opening Meant For Uniform Port Closure , Varied Staple Height Reloads / Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Varied Staple Height Reloads / Cartridges For 80 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Purple Varied Staple Height Of 3, 3.5 And 4Mm Leg Length , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob ( Both Side Firing ) , Linear Cutter Stapler With Integrated Gap Control Technology In 60 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 60 Mm Open Linear Cutterreloads / Cartridges Purpule And Black , Eea Circular Stapler Purple Colour Medium Thick , Triple Row With Tristaple Technology ( Three Row Of Staple Inner To Outer Row 3.0, 3.5 And 4.0 Mm With Sloped Cartridges Face In One Stapler ) Diameter 31Mm , Linear Cutter With Varied Staple Height, Tri-Staple Technology-Enabled Reloads Integration With Left And Right Firing Knob ( Both Side Firing ) , Linear Cutter Stapler With Integrated Gap Control Technology In 80 Mm Tristaple Gia Stapler, Compatible With Tri-Staple Gia 80 Mm Open Linear Cutterreloads / Cartridges Purpule And Black , Wound Protector With Double Ring Inmedium 5-9 Cm , Endo Catch Specimen Removal Kit:With Continuous Ring , Polyurethane Pouch With 34.5 Cm Shaft Length , 10Mm With Leakproof And Impervious Material To Cancer Cells Of 0.5 Microns / Pretied Purse String On Pouch Usfda Approved , Disposable Laparoscopic Clip Applier Preloaded With 16 Clips, 5Mm Diameter With Clip Logictechnology And Digital Display Titanium Clips- U Shaped , Laparoscopic Liner Cutterwithout Integrated Fresh Knife With 360*Rotation & 0-45* Articulation In Both Direction : For Use With Cartridges In Sizes Of 60Mm, Capable Of Loading All Length Cartridges On Same Gun Only , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device, 9Cm Length, 16Mm Curved Active Blade With Adaptive Tissue Technology Capable Of Sealing Blood Vessels Up To And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip- Focus 9 , Hand Activated Curved Taper Tip Coagulating Shears Compatible With Ultrasonic Cutting And Coagulation Device, 17Cm Length, 16Mm Curved Active Bladewith Adaptive Tissue Technologycapable Of Sealing Blood Vessels Upto And Including 5Mm In Diameter, With Ergonomic Symmetrical Finger Ring Grip - Focus 17 , Advance Bipolar Hand Activated Probe With 5Mm Shaft Diameter And 35 Cm Shaft Length With 5 Mm Wide Straight Jaw Design With Seal Length Of 20Mm And Cut Length Of 16Mm, Sealing Vessel Upto And Including 7Mm Through Radio Frequency Energy And Having A Temperature Controlled Mechanism Within The Jaw And Having Articulation Of 110 Degree ( 55 Degrees On Both Sides ) And Capable Of 360 Degrees Rotation , Advanced Bipolar Tissue Sealer 37 Cms, With 5Mm Shaft Diameter, 24 Mm Jaw Length, 21.8 Mm Cut Length And 13.4 Mm Jaw Aperture Designed For Use In Laproscopic Surgical Procedures With Curved And Tapered Tip And Uses An Advanced Algorithm For Intelligent And Efficient Energy Delivery. Device To Have Intuitive Design With Separate Seal And Cut Button And 360 Degree Continuous Shaft Rotation , Connecting Cable For Ultrasonic Harmonic Scalpel For Open Energy Probes Compatible With Focus Plus Shear- Hp Blue , Connecting Cable For Ultrasonic Harmonic Scalpel For Lap Energy Probes Compatible Withace Plus Shear Hp054 , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Plates - 2 Mm Thickness ( 2*2 ) Holedrill Bit Machine With Insertiontools , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Plates - 2 Mm Thickness ( 1*2 ) Holedrill Bit Machine With Insertiontools , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Plates - 2 Mm Thickness ( 1*1 ) Holedrill Bit Machine With Insertiontools , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Screw- ( 2 Mm ) Diameter Drill Bit Machine With Insertiontools , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Screw- ( 1.5 Mm ) Diameter Drill Bit Machine With Insertiontools , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Screw- ( 2.5 Mm ) Diameter Drill Bit Machine With Insertiontools , Platting For Maxillary Swing And Mandibular Fixation Surgeries ( Titanium ) Screw- ( 3 Mm ) Diameter Drill Bit Machine With Insertiontools , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 2.0, 2.5 And 3.0 Mm Staple Heights Rowfor Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife , Size 45 Mm Tan Colour Code For Vascular Applications , Curved Tip & Stepped Cartridges Face From Inner To Outer Side 3.0, 3.5 And 4.0 Mm Staple Heights Rowfor Variable Thickness Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife , Size 45 Mm Purpule Colour Code For Medium To Thick Tissue , Varied Staple Height Reloads / Cartridges For 60 Mm Gia Instruments With Tri-Staple Technology, With The Cutting Knife Blade Incorporated In The Reloads Itself, With Black Varied Staple Height Of 4, 4.5 And 5Mm Leg Length , Disposable 10 Mm Endoscopic Clip Applier With Facility Of Loading Clips Independent Of The Firing Mechanism: Medium / Large Size , Disposable Clip Applier Preloaded With 20 Clips, Superinterlock Security With Clip Designtechnology Medium , Close Wound Drainage Device Under Negative Pressure ( Closed Wound Suction Unit ) , Close Wound Drainage Device Under Negative Pressure ( Closed Wound Suction Unit ) , Close Wound Drainage Device Under Negative Pressure ( Closed Wound Suction Unit ) , Close Wound Drainage Device Under Negative Pressure ( Closed Wound Suction Unit ) , Urine Collecting Bag, Disposable 2000 Ml With Uroflow Meter , Microcatheter Selective Infusion Microcatheters For Deploying Intracranial Device: Stent Deployment , Microcatheter Selective Infusion Microcatheters For Flow Diverter Delivery With Single Tip Markers 0.027Inch , Micro Guide Wirefor Microcatheter Shapable Distal End And With Torque 0.014Inch , Aortic Punch 4 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Aortic Punch 4.5 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Aortic Punch 3.6Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue, Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Laproscopic Port With Trocar 5Mm Optically Guided Bladeless Trocar 5Mm With Bilateral Tissue Separators, Optical Tip To Eliminate Blind Entry, Clear Ribbed Cannula To Enhance Abdominal Wall Retention, Recessed Stopcock Valve, Funnel Shaped Housing, Duckbill Secondary Seal, Integrated Universal Seal That Eliminates The Use Of Reducer, 150Mm Length. , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. , Programmable Automatic Bipsy Gun With Compitible Co-Axial Needle Should Have 20Mm Sample Notch And Thin Wall Cannula For Larger Core And Echogenic Making On Both Stylet Tip And Cannula For Improved Visibility During Procedure. Should Have Three Programmable Firing Mode-Automatic Mode, Delay Mode And Zero Throw Mode. Should Have Two Firing Btton On Surface Of The Gun, Size 12G, 14G, 16G, 18G, 20G With Length 11Cm, 15Cm, 20Cm. Should Come With Compitible Coaxial Packed With Biopsy Gun. Usfda Approved. , Double Wall Resuscitator With Peep Valve In Adult- It Should Be Fully Autoclavable Double Wall With Hand Strap It Should Be Supplied With Autoclavable Reservoir Bag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult & Peadiatric It Should Have Provision To Attach Manometer For Paediatrics Ambu Bag Bag Volume: Mark Iv ( 1300 Ml ) Mark Iv Baby ( 300 Ml ) Weight: Adult ( 415 G ) Baby ( 190 G ) It Should Be Us-Fda, Ce & Iso Certified , Double Wall Resuscitator With Peep Valve In Paediatrics It Should Be Fully Autoclavable Double Wall With Hand Strap It Should Be Supplied With Autoclavable Reservoir Bag It Should Have A Single Shutter Valve System Made Of Silicone Rubber It Should Have Easy Attachment Of Peep Valve For Adult & Peadiatric It Should Have Provision To Attach Manometer For Paediatrics Ambu Bag Bag Volume: Mark Iv ( 1300 Ml ) Mark Iv Baby ( 300 Ml ) Weight: Adult ( 415 G ) Baby ( 190 G ) It Should Be Us-Fda, Ce & Iso Certified , Single Patient Use Sebs Resuscitator ( Spur Ii With Peep Valve In Neonatal ) • It Should Be Single Use Resuscitator Made To Sebs Material Not Pvc. • It Should Have Unique Single-Shutter Valve System For Reliable Functionality & Swivel Between Valve And Mask Permits 360° Positioning In Relation To The Patient • It Should Have Thin-Walled Compression Bag With Hand Strip. • Resuscitator Volume: Neonate ( 220Ml ) • ( Including Reservoir And Mask ) • It Should Be Ce / Iso, Us Fda Certified. , Pre-Formed Sga With Gastric Access & Intubationit Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett • It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector ( Iso ) . • It Should Be Ce / Iso, Us Fda Certified , Pre-Formed Sga With Gastric Access & Intubation It Should Be Latex Free Preformed Laryngeal Mask Having Gastric Access Channel And Should Be Used As A Conduit For Direct Endotracheal Intubation With Any Brand Ett • It Should Built-In, Anatomically Correct Curve And Cuff & Tube Moulded As A Single Unit. • Ultra-Thin Pilot Balloon With Tactile Indication Of Degree Of Inflation. • Universal 15Mm Connector ( Iso ) . • It Should Be Ce / Iso, Us Fda Certified , Silicone Pre-Formed Sga Total Size 8 • It Should Be And Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce / Iso, Us Fda Certified , Silicone Pre-Formed Sga• It Should Be And Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce / Iso, Us Fda Certified , Silicone Pre-Formed Sga• It Should Be And Autoclavable Up To 40 Times • It Should Have Reinforced Tip At Cuff And Cuff & Tube Moulded As A Single Unit. • Atraumatic Insertion And Removal. • It Should Be Ce / Iso, Us Fda Certified , Offset Connector Cardio Sensor Electrodes• It Should Have High Conductive Wet Gel To Ensure Reliable Traces. • It Should Be Design With Offset Connector To Prevent Artefacts From Disrupting The Readouts • It Should Have High Quality Ag / Agcl Sensor To Ensure Excellent Trace Quality • It Should Have Size Not More Than 72 X 68 Mm • • Sizes –Adult , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Disposable Sga Anatomical Curve • It Should Have Special Curve That Carefully Replicates Natural Human Anatomy • It Moulded Directly Into The Tube • Should Have A D-Shaped Airway Tube To Give A Firm And Ergonomically Grip During Insertion , Ultrasorbs Ap Disposable Drypads, Dry Pad For Moisture Management, 58.4X90cm, With Breathable Layer, Super Absorbent Core, Aqua Shield Film And Air Permeable Back Sheet, Absorbency Of 1800-2300Gm, Usfda / Ce / Bis Compliant, Iso13485 Compliant , Over-The-Ear Nasal Cannulaover-The-Ear Nasal Cannula With Star Lumen, 50 Tubing, Must Be Flexible Contoured Lip Tab Provides A High Level Of Stability And Patient Comfort. Over-The-Ear Design For A Comfortable And Secure Fit, Crush- And Kink-Resistant Tubing. Manufacturer Must Be Us-Fda Registered & Certified With En / Eu Iso 13485 & Applicable 510K & Ce Certification. , Volumetric Incentive Spirometer ( Adult ) Volumetric Incentive Spirometer ( Adult ) 4000 Ml With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En / Eu Iso 13485 & Applicable 510K & Ce Certification. , Volumetric Incentive Spirometer ( Pediatric ) Volumetric Incentive Spirometer ( Pediatric ) 2500 Ml With Handle. Volume Measurement Must Be Compact Comfortable Designed To Accommodate Large Inspired Volumes. Must Have Good-Better-Best Flow Window & Advanced, Low Work-Of-Breathing Design. Particulate Filter Screen In Device Housing Must Help To Reduce Risk Of Foreign Matter Passing To Patients. Expandable And Collapsible Tube Must Help Patients Find Comfortable Position For Treatments And Can Be Removed When Storing The Device. Ergonomic Swiveled Mouthpiece Allows To Patients Create Tight Seal To Enable More Accurate Measurement. Flow Indicator With Smiley Face Provides Visual Target For Desired Inhalation And Bright Green Flow Indicator Make It Easy For Patients To See Results. Manufacturer Must Be Us-Fda Registered & Certified With En / Eu Iso 13485 & Applicable 510K & Ce Certification. , Adult Conventional Single Water Trap , Adult Conventional Single Water Trap , Adult Ventilator Circuit Single Limb Portable , Adult Ventilator Circuit Single Water Trap , Fhme Heat And Moisture Exchangers With Bacteria Viral Filtersbacterial Filtration Efficiency≫ 99.99 % And Viral Filtration Efficiency ≫ 99.9999% . Filter Membrane Should Be Of A Hydrophobic Non-Woven Polypropylene Material. Should Be Tailored To Meet The Specific Needs Of Both Anaesthesia And Intensive Care. , Tracheostomy Hme:1 Heat And Moisture Exchangers For Spontaneously Breathing Tracheotomy Patients. 2 Should Have In Built Oxygen Port. 3 Should Be Compact & Light Wt. 4 Should Be Suitable For Ambulatory Patients, Sampling And Suctioning Can Be Done Without Removing It. 5 The System Should Have Kink Resisting Oxygen Tubing , Double Lumen Endobronchial Tube Left: Size-37Fr Low Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Double Lumen Endobronchial Tube Left:Size-39Fr Low Pressure Tracheal And Bronchial Cuffs To Minimise Risk Of Mucosal Damage. Color Coded Bronchial Cuff, Bronchial Proximal Lumen And Bronchial Pilot Balloon Assists In Location Of Tube And Tip When Verification Is Confirmed By Fiberoptic Bronchoscope. X-Ray Opaque Markers At Distal Tip Above Bronchial Cuff And At Tracheal Opening For Verification Of Tube Position. , Manifold Manifolds In 2, 3, 5 Port With Configuration Of Left-Right Orientation, On-Off Handle, Full-Half Body, 200 Psi-500 Psi Rating And Wide Port Spacing. Should Have Clear Polycarbonate Body To Provide Durability And Visibility, Airless Rotator And Large Bore Inner Lumen Throughout Including Rotator.Usfda Approved , High Pressure Tube High Pressure Tubing In 25Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda Approved , High Pressure Tube High Pressure Tubing In 51Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda Approved , High Pressure Tube High Pressure Tubing In 76, Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda Approved , High Pressure Tube High Pressure Tubing In122, Cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda Approved , High Pressure Tube High Pressure Tubing In183cm With Braided, Flexible Tubing Of Polyurethane Rated 1200 Psi. Usfda Approved , Torque Device Torque Device For .014 To .038 Standard And Hydrophilic Guide Wires With Squeeze-Load-Release Mechanism.Usfda Approved , Radial Band Radial Hemostatis Band In 24 Cm . Curved Backer Plat With Large Area & Clear Unobstructed Site Visibility, Convinient Tubing Clip With Two Check Valve Options And Device Stickers. Should Be Available With Standard Luer And Specialized Connection Syringe. Us Fda Approved , Radial Band Radial Hemostatis Band In 29 Cm. Curved Backer Plat With Large Area & Clear Unobstructed Site Visibility, Convinient Tubing Clip With Two Check Valve Options And Device Stickers. Should Be Available With Standard Luer And Specialized Connection Syringe. Us Fda Approved , Angiography Needleangiography Needle In 18G, Length Of 2-9Cm. Should Be Available In Echo Enhanced & Smooth Finish, Ergonomic Hub With Bevel Orientation Point, Silicone Coated Stainless Steel To Reduce Needle Drag And Superior Sharpness To Facilitate Entry Into Tissue And Vessel Wall. Usfda Approved , Angiography Needleangiography Needle In 20G, Length Of 2-9Cm. Should Be Available In Echo Enhanced & Smooth Finish, Ergonomic Hub With Bevel Orientation Point, Silicone Coated Stainless Steel To Reduce Needle Drag And Superior Sharpness To Facilitate Entry Into Tissue And Vessel Wall. Usfda Approved , Angiography Wire Ptfe Guidewire In .035, .038, In Regular Length. Should Have 3Mm J-Tip, Straight Tip, Pre-Coating For Smooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memory And Packed In Flush Hoop With J Straightener. Should Have Option Of Fixed Core, Movable Core, Heparin Coating, 1.5Mm J-Tip. Usfda Approved , Angiography Wire Long Length Ptfe Guidewire In .035, .038, With Exchange Length. Should Have 3Mm J-Tip, Straight Tip, Pre-Coating For Smooth Surface With Less Friction, Finger Straight-Able With Precise J-Tip Memory And Packed In Flush Hoop With J Straightener. Should Have Option Of Fixed Core, Movable Core, Heparin Coating, 1.5Mm J-Tip. Usfda Approved , Hydrophilic Wire Long Lengthhydrophilic Guidewire Of .018, .025, .035, .038 In 180Cm, 220Cm, 260Cm Length With Straight, Angled Tip. Should Come In Stiff & Standard Configuration, Nitinol Core Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visibility, Hydrated Gel Coating And True 1:1 Torque. Usfda Approved , Hydrophilic Wire Long Lengthhydrophilic Guidewire Of .018, .025, .035, .038 In 180Cm, 220Cm, 260Cm Length With Straight, Angled Tip. Should Come In Stiff & Standard Configuration, Nitinol Core Polyurethane Jacket Hydrophilic Coated Guide Wires With Radiopaque Jacket For Enhanced Visibility, Hydrated Gel Coating And True 1:1 Torque. Usfda Approved , Hydrophillic Braided Sheathhydrophilic Braided Sheath Introducer In 4F To 7F, Length Of 7, 11, 16, 23Cm With The Option Of .018, .021, .025 Plastic Jacketed And Spring Coil Guidewire. Should Have Ultra-Thin Wall And Flat Wire Braiding Technology To Provide Support And Low Profile.Usfda Approved , Femoral Sheath With Needle Femoral Sheath In 5F To 8F, Length Of 11-23Cm With Puncher Needle Of 18G And Guidewire Of .035, .038. Should Have Rotating Suture Ring, Snap-Fit Dilator To Prevent Slipping During Insertion And Holster Pack. Should Be Available In Polypropylene. Usfda Approved , Angiography Catheterdiagnostic Catheter In 4F-6F, Length Of 70-110Cm & 125Cm , Should Come In Various Shapes & Curve Length Including Jl & Jr ( 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 6 Cm ) , Al, Ar, Tig, Mp, Im, Sones, Pigtail ( Straight, Angle, Radial ) . Should Have Flat Wire Braiding, Nylon Material, Thin Wall Design For Higher Flow Rates, Radio-Opaque Tip, Strain Relief And Winged Polycarbonate Hub. Should Be Available In Various Configurations- Braided, Non Braided, Short Tip, Bumper Tip, Sideholes As Applicable. Usfda Approved , Angiography Radial Cathetersdiagnostic Radial Catheter With Radial Ultimate Curve In 4-6F. Lenght Of 100Cm, 110Cm, 125Cm. Should Have Four Type Of Radial Ultimate Curves. Should Have Flat Wire Braiding, Nylon Material, Thin Wall Design For Higher Flow Rates, Radio-Opaque Tip, Strain Relief And Winged Polycarbonate Hub. Us Fda Approved , One Loop & Triple Loop Snaresnare Kit ( 2-35Mm Diameter, 90-Degree Nitinol & Gold-Plated Tungsten Loop ) And Multiloop Snare Kit ( 2-45Mm Diameter, Three Interlaced Nitinol Loops ) For Foreign Body Retrieval, Should Come With Flexible, Reinforced, Strain Relief Hub To Reduce Buckling And Unique Peel Away Insertion Tool. Usfda Approved , Ptca Kit ( 1 ) Three Port Manifold With Knobs To TurnRight When Open ( 2 ) One Pressure Line, ( 3 ) Fluid Connecting Line, ( 4 ) Contrast Connecting Line, ( 5 ) One Three Way Stop Cock, ( 6 ) One Y-Connector Hemoststic Valve With Spring Type Push And Release Mechanism, ( 7 ) One Inflation Device With Manometer Upto 30 Atm ( Easy To Operate With Luminescent Dial ) , ( 8 ) One Luer Lock Controlled Syringe Of 10 Ml With Finger Grip, ( 9 ) Insertion Needle, ( 10 ) Torque Device.Usfda Approved , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane, Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3Mm. , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane, Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 3.5Mm. , Paediatric Endotracheal Tube Paediatric Microcuff Designed According To The Paediatric Anatomy.Cuff Is Made Up Of Polyurethane, Thickness Of Cuff Is 10 Microns.Microcuff Seals At An Average Cuff Pressure Of 11 Cmh2o.Burst Pressure Of Cuff Is 805Cmh2o.Anatomically Based Intubation Depth Marking With Precision Bands.Cuff With Play Mode Function. Sizes Are 5.5Mm , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering. T Size 13Fr . , Kimvent Bal Cath Non Bronchoscopic Bal For Bronchial Aspirate Sampling. Can Be Performed In Minutes At Bedside. Directional Tip Allows Right Or Left Lung Sampling.Maintains Peep When Used With Supplied Ventilator Adapter. Soft, Cushioned, Radiopaque Tip For Safe Sampling. Protected With Outer Catheter Covering.Sizes16fr. , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip, Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radiopaque Stripe, Gamma Sterilizedsize – 20 Length ( 0.8 – 5.0 ) , Gastrostomy Feeding Tube Medical Grade Silicone Construction.Low Profile Design.Tapered Distal Tip, Silicone Internal Retention Balloon.Distal Tip Recessed At 5M.Lproximal Anti Reflux Valve.Secur Lok Extention Set Connector Mechanism, Radiopaque Stripe, Gamma Sterilized Size – 24Fr Length ( 0.8 – 5.0 ) , Percutaneous Endoscopic Gastrostomy ( Peg ) Medical Grade Silicone Construction.External Retention Ring .Universal And Bolus Feeding Port Connectors, Medication Port.Collapsible Internal Retention Bumper.Radiopaque Stripe And Bumper.Tubing Clamp.Eto Sterilized.Sizes – 24Fr , Anti Microbial Gloves , Anti Microbial Gloves , Anti Microbial Gloves , Anti Microbial Gloves , Anti Microbial Gloves , Anterior Chamber Iolpmma Material, Single Piecekelman Multiflex Design5-6 Mm Optic Size With 12-13 Mm Overall Size Biconvex Power Range +12 To +24Should Be Iso Or Ce Certified. Manufacturer Should Be Asked To Sample For Approval. , Capsular Tension Ring Standard Capsular Tension Ringpmma Material With One Eyelet Each At Each End 10 Mm To 12 Mm Overall Diameter Sterile Should Be Iso / Ce Certified Mfg. , Neonatal High Flow Nasal Cannula Having8 Litre Flow. Should Have Soft Tip . , Long Introducer Sheath ( 20-30 Cm Long ) ( Size 5Fr.. ) Us Fda + Ce / Dgci Approved· Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath ( 20-30 Cm Long ) ( Size 6Fr. ) Us Fda + Ce / Dgci Approved· .· Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath ( 20-30 Cm Long ) ( Size 7Fr. ) Us Fda + Ce / Dgci Approved· · Sheath Should Be Between 20-30 Cm Long· 0.035 Or 0.038 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 4F-6F Us Fda + Ce / Dgci Approved· Sizes 4 French 10-20 Cm Long· Pack Must Include 18 G, -21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 4F-6F Us Fda + Ce / Dgci Approved· Sizes 5 French 10-20 Cm Long· Pack Must Include 18 G, -21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Trans Radial Introducer Sheeths 4F-6F Us Fda + Ce / Dgci Approved· Sizes6 French 10-20 Cm Long· Pack Must Include 18 G, -21 G, 6-7.5 Cm Long Puncture Needle· 0.025 Inch Guide Wire Compatible· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce / Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access Us Fda + Ce / Dgci Approved· Between 7-11 Cm Long · 0.021 Or 0.025 Inch Guide Wire Compatible · With Haemostatic Valve To Prevent Back Leak And Air Aspiration· Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· With Smooth And Resistance Free Insertion , Ptfe Coated Diagnostic Guide Wire – ( Regular Length, Regular Stiffness ) Us Fda + Ce / Dgci Approved· Should Be Available In 0.035Size· Should Be Between 145-180 Cm Long· Should Be Available As Straight & J-Shaped Tip· Should Be Available In Variable Lengths Of Flexible / Floppy End· Should Be Available In Variable J Tip Sizes· Should Be Available Fixed As Well As Movable Core. , Ptfe Coated Diagnostic Guide Wire – ( Exchange Length, Regular Stiffness ) Us Fda + Ce / Dgci Approved· Should Be Available In , 0.035 Inches Size· Should Be 240-300 Cm Long· Should Be Available As Straight Or J-Shaped Tip· Should Be Available Fixed As Well As Movable Core. , Hydrophilic Diagnostic Guide Wire – Radifocus Tarumo Type ( Regular Length, Regular Stiffness ) Us Fda + Ce / Dgci Approved· Should Be Available In 0.032 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 120-300 Cm Long , Hydrophilic Diagnostic Guide Wire – Radifocus Tarumo Type ( Regular Length, Regular Stiffness ) Us Fda + Ce / Dgci Approved· Should Be Available In0.035 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 120-300 Cm Long , Radiofocus Miniplastic Guidewire ( , Regular Stiffness ) Us Fda + Ce / Dgci Approved· Sould Be Available In0.035 Inches Size· Should Have Superelastic Alloy Core· Should Have Super Flexible Wire Tip· Should Be Available In Straight And Angled Tip· Should Be Between 150-180 Cm Long , Judkins Catheter ( Jr ) Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter ( Jr ) Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter ( Jr ) Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter ( Jr ) 8Fr , Judkins Catheter ( Jl ) Us Fda + Ce / Dgci Approved4fr , Judkins Catheter ( Jl ) Us Fda + Ce / Dgci Approved ·Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter ( Jl ) Us Fda + Ce / Dgci Approved ·Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter ( Jl ) Us Fda + Ce / Dgci Approved ·Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter Pigtail Us Fda + Ce / Dgci Approved Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter Pigtail Us Fda + Ce / Dgci Approved Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Judkins Catheter Pigtail Us Fda + Ce / Dgci Approved Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Multipurpose Catheterus Fda + Ce / Dgci Approvedmultipurpose Catheters In Various Standard Curves And Lengths. , Amplatz Catheterus Fda + Ce / Dgci Approved Amplatz Left ( Al ) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheterus Fda + Ce / Dgci Approved Amplatz Left ( Al ) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheterus Fda + Ce / Dgci Approved Amplatz Left ( Al ) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheterus Fda + Ce / Dgci Approvedamplatz Right ( Ar ) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheterus Fda + Ce / Dgci Approved Amplatz Right ( Ar ) Catheter In Various Standard Curves And Lengths. · , Amplatz Catheterus Fda + Ce / Dgci Approvedamplatz Right ( Ar ) Catheter In Various Standard Curves And Lengths. · , Internal Mammary Catheter Us Fda + Ce / Dgci Approved · In Various Standard Curves And Lengths. , Internal Mammary Catheter Us Fda + Ce / Dgci Approved · In Various Standard Curves And Lengths. , Internal Mammary Catheter Us Fda + Ce / Dgci Approved · In Various Standard Curves And Lengths. , By-Pass Graft Catheterus Fda + Ce / Dgci Approved, In Various Standard Curves And Lengths. , By-Pass Graft Catheterus Fda + Ce / Dgci Approved, In Various Standard Curves And Lengths. , By-Pass Graft Catheterus Fda + Ce / Dgci Approved, In Various Standard Curves And Lengths. , Transradial Diagnostic Coronary Catheter Tiger Type Diagnostic Coronary Catheters Of Tig Curves And Lengths Dedicated For Trans Radial Coronary Angiography And Brachial Approach Also Us Fda + Ce / Dgci Approved · , Introducer Sheaths For Pediatric Use ( Size 5 Fr. ) With J Tip / Straight Introducer Wire Us Fda + Ce / Dgci Approved· Between 5.5-7.5 Cm Long· 0.021 Inch Straight Introducer Guide Wire· With Haemostatic Valve To Prevent Back Leak And Air Aspiration· With Integral Side Port With Attached 3-Way Stopcock· With Suture Eye For Securing Sheath· Kink Resistant· With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion· Should Have Smooth And Resistance Free Insertion , Angio.Kit / Ptca Kit ( 3 Port Many Fold With Attached Tubing One Pressure Line + Two Iv Set Connecting Tube And Two Leurlock Syringe ) Us Fda / Ce / Approved , Bone Marrow Biopsy Needle With Diamond Bevel Tip & Tapered Distal Canula. Disposable Bone Marrow Biopsy Needle Should Have Ergonomic T- Handle Design With Seprate Handle Cap. Should Have Trocar / Diamond Tip For Easy Coring Of Bone. Should Have Triple Crown Cannula Tip With 6 Facets.Should Be Available With Narrow Acquition Cardle With Sample Size Verfication Marking Should Be Available In 8, 11, 13 Gauze Usfda / Ce Approved , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium ( Coated Internally & Externally Surfaces ) , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium ( Coated Internally & Externally Surfaces ) , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium ( Coated Internally & Externally Surfaces ) , Silicone Foleys Catheterwith Three Noble Metal Alloy Coating Consisting Of Gold, Silver & Palladium ( Coated Internally & Externally Surfaces ) , Cutting & Coagulations Device With Tissue Fusion Ligasure Technology Having Maryland Jaw Sealer And Divider With Wide Jaw Aperture 13Mm And Cut Length 18.5Mm With Shaft Rotation Of 350 Degrees And With One Step Sealing Mechanism. Should Have The Manual Cutting Mechanism. And It Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligature Technology Have Small Jaw Tissue Sealing System For Open Procedures Vessel Sealing Instrument With Cut Length Of 14.7 Mm, Seal Length Of 16.5Mm, Jaw Angle 28 Degrees. Should Have The Manual Cutting Mechanism.And Its Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligature Technology Laparoscopic Blunt Tipped Vessel Sealer And Divider 37 Cm Long 5Mm Instrument. Wide Jaw Aperture 14.5 Mm With Shaft Rotation Of 180 Degrees ; Multifunctional Laparoscopic Device For Tissue Fusion.And Its Should Have Including 7Mm Cutting And Coag With Usfda . , Cutting &Coagulations Device With Tissue Fusion Ligasuretechnologyhave36mm Jaw Length, 180 Degree Rotatable Instrument With Curved Blade For Large Volume Tissue. Should Have The Manual Cutting Mechanism. , Double Lumen Catheter With Kit Internal Juglar / Straight ( Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter , Dialator , Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot , Double Lumen Catheter With Kit Internal Juglar / Straight ( Catheter Should Be Madeup Of Flexible Radiopaque Polyurethane With A Radiopaque Tip, Easy Visualization In X-Ray. Accessory Should Be Provided Like Catheter , Dialator , Introducer, Needle 18 G, Guidewire With Dispencer And Injection Caps. Catheter Should Be D To Have Consistent Blood Flow With Laser Cut Side Slot , Long Term Double Lumen Dialysis Cathetersize- 14.5 Frx23 Cm ( Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter, Pull Apart Sheath, Dialator, Tunneling Stylet, Guide Wire J / S, With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade ) Size- 14.5 Frx23 Cm Usfda Certification Along With Iso, Ce , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter, Pull Apart Sheath, Dialator, Tunneling Stylet, Guide Wire J / S, With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Long Term Double Lumen Dialysis Catheter With Kit Accessories Should Be Provided ( Catheter, Pull Apart Sheath, Dialator, Tunneling Stylet, Guide Wire J / S, With Disppencer And Injection Caps, Symmetrical Tip Retrograde And Antigrade , Multi-Vent Mask Pediatric, Multi-Vent Mask Pediatric, Air Entrainment Masks, Must Be Safe, Simple Delivery Of Variable Oxygen Concentrations. Each Mask To Includes Color-Coded Diluters: Green For Low Concentration, White For Medium Concentration. Locking Ring To Secure Flow Setting. Must Include Adaptor For High Humidity Entrainment. Complete Kit With 7-Ft Oxygen Tubing. Manufacturer Must Be Us-Fda Registered & Certified With En / Eu Iso 13485 & Applicable 510K & Ce Certification. , Closed Suction Catheter Mdi Porthas Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip With Mdi Port.Catheter Is Made Up Of Medical Grade Silicon Material, Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. , Closed Suction Catheter Mdi Porthas Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip With Mdi Port.Catheter Is Made Up Of Medical Grade Silicon Material, Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. , Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon Material, Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. , Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon Material, Catheter Has Zig-Zag Ports For Better Suctioning. Twin Peep Seals. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. , Multifocal Iolbiconvex, Single Piece Designoptic Size 6 Mm, Overall 12-13 Mm Sizetwo Haptics, Modified Cuv Blocking Capability360 Degrees Square Edge, Sterile Packingfoldable Lens With Insertion Via Injector, Should Able To Insert In Sub 2.8 M.Msterile Disposable Injector With Cartridge Along With Each Iolinjector Should Be Of Good Quality With Smooth Injection Without Damaging Ioldiopters Required +16 To +25 Ddiffractive Multifocal Design With +3 To +4 Dioptre Additionshould Be Iso Or Ce Certifiedmanufacturer Should Be Asked To Supply Samples For Approval3 Piece Feldable 11-28 D , Glaucoma Drainage Implant ( Valved ) With Silicon Tubeadult , Glaucoma Drainage Implant ( Valved ) With Silicon Tube Paediatric , Scleral Fixiated Intraoccular Lense Having Multifoccal Toric , Three Piece Foldable Intraoccular Lense , Antimicrobial Silver Dresssingsterilenon-Occulusive Woundcontact Layer Consists Of Silver Healing Matrix Made Of Polyester Mesh Impregnated With Hydrocolloid Particles ( Cmc ) , Petroleum Jelly, Polymers And Silver Salts With Demonstrated In Vitro Antibacterial Activity Upto 7 Days, Using Patented Lipido- Colloid Technology ( Tlc ) , Sterile Self Adherent With Lipido Colloid Technologysterile Self -Adherentpatented Tlc Matrix ( Lipido Colloid Technology ) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad , A Superabsorbent Layer , A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. , Sterile Self Adherent With Lipido Colloid Technologysterile Self -Adherentpatented Tlc Matrix ( Lipido Colloid Technology ) Wound Contact Layer Combined Withabsorbent Polyurethane Foam Pad , A Superabsorbent Layer , A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. , Nasal Oxygen Cannula ( Set ) , Twin Bore ( Accessory For Compressed Air Breathing ) All Sizes ( Adult & Paediatric ) Each Piece Aphysical , Ecg Electrode •Reliable Trace, •High Conductivity, • Easy To Handle , Three Dimensional Monofilament Polyester Marking Size 15 Cm Circular , Three Dimensional Monofilament Polyester Marking Size 20X15 Cm Circular , Light Weight Monofilament Polypropylene Mesh Size Large Left10.8*16Cm / 15*10 Cm , Light Weight Monofilament Polypropylene Mesh Size Large Right 10.8*16Cm / 15*10 Cm , Light Weight Monofilament Polypropylene Mesh Size Extra Large Left12.4Cm * 17.3 / 16*12 Cm , Light Weight Monofilament Polypropylene Mesh Size Extra Large Right 12.4Cm * 17.3 / 16*12 Cm , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 2*4Cm , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 5*10Cm , Central Neck Line- Double Lumen ( 3 Nobel Metal Coated ( Gold, Silver, Palladium ) Central Lumen Catheter, Double Lumen , Microcatheter Selective Infusion Microcatheters For Intra Cranial Aneurysm Treatment With 2 Tip Markers , Microcatheterflow Dependent , Surgical Gloves 6.5 Puncture Indicator Technology , Surgical Gloves 7 Puncture Indicator Technology , Surgical Gloves 7.5Puncture Indicator Technology , Ionic Silver Dressings For Low To High Exuding Wounds10 Cms X 10 Cms , Self Adherent Moist Wound Dressing10 Cms X 10 Cms , Pediatric Nasal Cannula 7 Star-Lumen Tubing , Adult Mask For Tracheostomy , Pardiatric Mask For Tracheostomy , Elongated Aerosol Mask Adult , Infant Prong Cpap Cannula , Closed Suction Catheter For Paediatrics 5Fr , Closed Suction Catheter For Paediatrics 6Fr , Closed Suction Catheter For Paediatrics 7Fr , Closed Suction Catheter For Paediatrics 8Fr , Closed Suction Catheter For Paediatrics 10Fr , Closed Suction Catheter For Paediatrics 12Fr , Catheter Mount , Arterial Pressure Monitor Lines ( 100 Cm Long ) , Arterial Pressure Monitor Lines ( 150 Cm Long ) , Arterial Pressure Monitor Lines ( 200 Cm Long ) , Transperant Surgical Wound Dressing Size- 6X 7 Transperant Surgical Wound Dressing Size- 6X 7 , Transperant Surgical Wound Dressingsize- 10X15 , Transperant Surgical Wound Dressingsize- 10X30 , Transperant Surgical Wound Dressing Size- 10X40 , Central Line Triple Lumen 8.5 Fr With 16Cm / 20Cm Catheter , Post Operative Surgical Cover Dressings Hydrofiber Dressings 9X30cm , Post Operative Surgical Cover Dressings Hydrofiber Dressings 9X35 Cm
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
44.
Housing Urban and Rular Development #8979082 Technical Bid
Tender For Electrical Work - &P 2 Fire Fighting Work Fire Pumps And Accessories: Supplying, Installation, Testingand Commissioningof Electric Driven Main Fire Pump Suitablefor Automatic Operationandconsistingoffollowing, Completeinall Respects, As Required :A ) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.C ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.D ) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. E ) Suitablecementconcretefoundationdulyplastered With Anti Vibration Pads. F ) 2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 3 Supplying, Installation, Testingandcommissioningof Diesel Engine Driven Main Fire Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required : ( Diesel Driven Pump ) A ) Horizontal Type, Multistage, Centrifugal Pump Of Cast Of Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitablehp, 1500Rpmwatercooledwithradiator, Diesel Engine Conforming To Relevant Is Standard Completewithautostartingmechanism, 12 / 24Volts Electricstartingequipment, Dieseltank, Exhaustpipe Extended Upto 10 M Outside Pump House Duly Insulated With 50 Mm Thick Glass Wool With 1.0 Mm Thick Aluminium Sheet Cladding, Residential Silencer, Instruments And Protection As Per Standard Specification, Stop Solenoid For Auto Stop In The Event Of Fault With Audio Indications, Painted With Post Office Red Colour Etc. As Required. C ) M.S Fabricated, Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. D ) Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 4 Supplying, Installation, Testingandcommissioningof Electricdrivenpressurisationpumpsuitablefor Automaticoperationandconsistingoffollowing, Complete In All Respects, As Required : ( Jockey Pump ) A ) .Horizontaltype, Multistage, Centrifugalpumpofcast Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is : 1520. B ) .Suitablehpsquirellcageinductionmotortefctype Suitableforoperationon415volts, 3Phase50hz Ac Supply With Ip 55 Class Of Protection For Enclosure, Horizontalfootmountedtypewithclass-FInsulation, Conforming To Is : 325. C ) .M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required.D ) .Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.180 Lpm At 70 M Head 5 Control Panels: Fabrication, Supply, Insallation Testing & Commissioning Of Electrical Control Panel Of Cubical Construction, Floor Mounted Type, Fabricated Out Of 2Mm Thick Crca Sheet, Compartmentalisedwithhingedlockabledoors, Dustandverminproof, Powdercoatedofapproved Shade After 7 Tank Treatment Process, Cable Alley, Inter-Connection With Suitable Sizecopperconductor Cable / Solidcopper Strip, Havingswitchgears And Accessories, Mountings And Internal Wiring, Earth Terminals, Numbering Etc. Complete In All Respect, Suitableformainfirepump, Pressurisationpump& Dieselpumpsetcompleteaspercpwdspecification Withfollowingincomingandoutgoings, Suitablefor Operationon415v, 3Phase, 50Hzacsupplywith Enclosure Protection Class Ip 42 As Required :Incomings:A ) 630A, 50Ka4 Pole Mccb, Ics=100% Icu Rating Digital Voltmeter 0-500V With Selector Switch Ammeter ( 0-630 A ) With Selector Swtich & Cts Etc.B ) Ledtyperybphaseindicatinglamps, On, Off, Trip Indicating Lampsset Of Copperbus Bar 800Ampsoutgoings: Main Fire Pump :200Amp, 50Katpnmccb, Ics=100%Icu, Withfully Automatic Star / Delta Starter Suitable For 75 Hp Pump With Overloadprotection, Currentsensingtypesinglephase Preventorcompletewithallacceessoriesandinternal Wiringrequiredforautomaticoperation, Selectorswitch For Local / Remote, Auto / Manual / Off Operation. - 2 Setsjockey Pump:100 Amp, 50Ka Tpn Mccb, Ics=100% Icu, With Suitable Hp Fully Automatic Star / Delta Starter With Overload Protection, Currentsensingtypesinglephasepreventor Complete With All Acceessories And Internal Wiring Requiredforautomaticoperation, Selector Switchfor Local / Remote, Auto / Manual / Off Operation. - 2 Setsdiesel Engine Controla ) Control For Diesel Engine Comprising - Automatic / Manualselctorswitch&3Attemptsstarting Device, Timersandrelaysasrequired, Pushbuttons, Start / Stop In Manual Modeb ) Indicatinglampforhigh / Lowlub.Oilpressure, High Water Temp And Engine On Indicationc ) Batterychargersuitbalefor12v / 24Vdcwithboost And Trickle Selector Switch, 0-30 V Dc Volt Meter, And 020 A Dc Ammeter All Standard Relays And Accessories For Automatic Operation Of Diesel Engine.System Controller: Designing, Supply, Installation, Testingand Commissioning Of System Controller To Control Operation Of Main Electric Fire Pump, Diesel Pump, Pressurization Pump, Terrace Pump In Sequence As Per Specification Consisting Of Relays, Timers. Sensors, Annunciation Windowforfaultindication, Complete As Per Specification 6 Providinglaying, Testing&CommissioningofCClass Heavydutymspipeconformingtois1239 / 3589I / C Fittingslikeelbows, Tees, Flanges, Tapers, Nutsbolts, Gasketsetc.Ingroundincludingwelding, Excavation& Providingcementconcreteblocksassupports, Anticorrosivetreatmentwithcoaltar / Asphalttapeasper Is10221, Refillingthetrenchetc.Offollowingsizes Complete As Required. 200 Mm. Dia ( Wall Thickness = 6.3 Mm ) 7 150 Mm. Dia 8 Providing, Laying, Testing&Commissioningof CClass Heavydutymspipeconformingtois3589 / Is1239 Includingwelding, Fittingslikeelbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : 25 Mm Dia 9 32 Mm Dia 10 40 Mm Dia 11 50 Mm Dia 12 65 Mm Dia 13 80 Mm Dia 14 100 Mm Dia 15 150 Mm Dia 16 Providing, Laying, Testing&CommissioningofBClass Heavydutyg.I.Pipeconformingtois1239including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts, Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Ormorecoatsofsyntheticenamelpaintofrequired Shade Complete As Required: 25 Mm 17 32 Mm 18 40 Mm 19 50 Mm 20 65 Mm 21 80 Mm 22 100 Mm 23 150 Mm 24 Supplyingandfixingsingleheadedinternalhydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheelisi Marked Conformingtois5290 ( Type-A ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 25 Supplying And Fixing Single Headed External Yard Hydrant Valve With 1 No. 63 Mm Dia Instantaneous Fm Gunmetal / Stainlesssteel Couplingand Cast Iron Wheel, Isimarked, Conformingtois5290 ( Typea ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 26 Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Markedcompletewithnuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required :80 Mm Dia 27 100 Mm Dia 28 150 Mm Dia 29 Supplying, Fixing, Testing&Commissioningofdouble Flangedsluicevalveofratingpn1.6Withnonrising Spindle, Bronze / Gunmetalseat, Isimarkedcomplete With Nuts, Bolts, Washers, Gaskets And Conforming To Is 780 Of Following Sizes As Required : 80Mm Dia 30 100Mm Dia 31 150Mm Dia 32 200Mm Dia 33 250Mm Dia 34 Supplyingandfixingorificeplatemadeoutof6mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Sizetobefitted Betweenflange&Landingvalveof Externalandinternalhydrantstoreducepressureat The Outlettothe Levelof 3.5Kg / Cm2 Complete As Required. 35 Providing, Installation, Testingandcommissioningof Non-Returnvalveoffollowingsizesconfirmingtois: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.100Mm Dia 36 150Mm Dia 37 200Mm Dia 38 Providing, Installation, Testingandcommissioningof Stainlesssteely-Strainerfabricatedoutof1.6Mm Thickstainlesssteel, Grade304, Sheetwith3mmdia Holes With Stainless Steel Flange.150Mm Dia 39 200Mm Dia 40 Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipewith63mmdiamaleandfemalecouplingsduly Boundwithgiwire, Rivetsetc.Conformingtois636 ( Type-A ) As Required : Gun Metal 41 Supplying Andfixing First-Aidhosereelwithms Constructionspraypaintedinpostofficered, Conformingtois884completewiththefollowingas Required. A ) . 20Mmnominalinternaldiawaterhosethermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 B ) .20Mmnominalinternaldiagunmetalglobevalve& Nozzle. C ) .Drum And Brackets For Fixing The Equipmets On Wall.D ) .Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. E ) .40 M 42 Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Sizenozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Gun Metal 43 Supplyingandfixingoffirebrigadeconnectionof Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplingscompletewithcapandchainasreqd.For Suitabledia Ms Pipe Connectionconforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe 44 4 Way - 150 Mm Dia M.S. Pipe 45 3 Way - 150 Mm Dia M.S. Pipe 46 Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valveontopandflangedconnectiontoriser, Drain Arrangementwith25mmdiagunmetalwheelvalve Withrequiredaccessories, Pressuregaugeand Paintingwith Synthetic Enamel Paint Of Approved Shade As Required. 47 Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoidbulbtypesprinklersofrating68degree Centigrade With Required Accessories :Pendent Sprinkler 48 Upright Sprinkler 49 Horizontal Side Wall Sprinkler 50 Concealed Sprinkler 51 Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. 52 Providing& Fixingflowswitchinfollowingsizesm.S. Pipe Including Connection Etc As Required. 53 100Mm Dia 54 150Mm Dia 55 Providing, Fixing, Testing & Commissioning Of Installationcontrolvalveofcastironbody, Brass / Bronzeworking Partscomprisingofwater Motor Alarm, Bronzeseatclapper, Clapperarmand Hydraulicallydrivenmechanicalgongbelltosound Continuousalarmwhenthewetriser / Sprinklersystem Activates, Pressuregauges, Emergencyreleases, Strainer, Pressureswitch, Cockvalvecompletewith Drainvalveandbypass, Testcontrolbox, Ballvalves, Ms Pipe Of Required Size, Flanges, Orifice Plate, Gasket Etc Of Follwing Sizes Asrequired : 150Mm Dia 56 Supplying, Installation, Testing & Commissioning Of Sprinklerflexiblepipe ( Ullisted ) Ofstainlesssteel Complete With 15 Npt On Reducer Thread With Maximum Working Pressure Of 175 Psi Test Pressure Of 875Psi ( Burst ) Withbranchline ( Inlet ) 25Mmnpt Malethreadtosprinklerhead ( Outlet ) 15Mmnpt Femalethreadwithreducer, Nipple, 2Sidebrackets, Center Bracket, Stockbar Of Following Sizes Complete As Required.700Mm 57 1000Mm 58 1200Mm 59 1500Mm 60 Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required ( E&M ) 61 Providing And Fixing Ms Cabinet ( Size 750X600x250 Mm ) Fabricated From 16 Gauge Ms Sheet With Full Front Glass Door & Locking Arrangement For Pad Lockwith Suitable Shelves For Keeping 25 Nos. Spare Sprinklers & One No. Spanner Properly Fixed In Shelves. Cabinet Shall Be Painted With Enamel Paint Of Approved Shade. ( Cost Shall Include 20 Nos. Spare Sprinklers ( 5 Nos Side Wall 20Nos Pendent, One No. Spanner And 5 Rolls Of Teflon Tape ) . Note: All Valves Shall Be Of Pn16 Rating 62 Portable Fire Extinguishers: Providing & Fixing Of Isi Marked ( Is:15683 ) Portable Fire Extinguisher, Carbondioxide Type Flat Base Including Valve, Discharge Hose Of Not Less Than 10 Mm Dia. 1 M Long & Complete In All Respects Including Initial Fill With Co2 Gas Confirming To Is:307-1966 Filled To A Filling Ratio Of Not More Than 0.667 Of Not More Than 0.667 And Wall Suspension Bracket Capacity 4.5 Kg 63 6 Kg. Abc Powder Type Fire Extinguishers Are Manufactured And Marked To Indian Standard Is: 15683. Suitable First Aid Appliance For Fighting Fires In Class A, B & C Fire That Is Wood, Textile, Flammable Liquids & Gases. 64 Providing And Fixing Mechanical Foam Type Fire Extingushers Consisting Of Welded M.S. Trolley Mounted Cylindrical Body, Squeeze Lever Discharge Valve Fitted With Pressure Discharge Hose, Discharge Nozzle, Trolley Etc., Isi Marked As Per Is:Is:13386 Finished Externally With Red Enamel Paint.Capacity 50 Lit ( D.G.Room ) 65 Providing And Fixing Carbon-Di-Oxide Fire Extingushers Trolley Mounted With All Accessories Internal Discharge Tube, High Pressure Discharge Hose, Discharge Nozzle, Isi Marked As Per Is:2878 Finished Externally With Red Enamel Paint. Capacity 22.5 Kg. 66 Boq-D: Plumbing Pump & Equipmentswater Supply, Drainage, Pumps & Equipment :Providingand Fixing Centralized Water Level Controller Cum Indicator System, As Per The Following Details:Centralised Plc Control Panel : Along With Touch-Screen Display Board ( Min. 8 Diag. Size ) Along With All Accessories For Complete Controls & Indication. Panel Shall Be Made Out Of Crca Sheet Min. 2Mm Thick Having Necessary Interlocks, I / OS, Required Number Of Repeater Amplifiers, All Audio-Visual Alarms As Required Specifications As Listed Below. An Emergency Stop Push Button Shall Be Provided In The Panel. The Panel Shall Have Modbus Compatibility For Seamless Bms / Bas Integration And Shall Be Of Approved Make. The Complete System Control Matrix, Wiring Diagram, SldS And Technical Details Shall Be Submitted By The Vendor And Gotten Approved Before Commencement Of Execution Of Works. Water Level Indicators Cum Controllers :Working On Hydrostatic Pressure Measurement Principle Made Of Stainless Steel For Installation On Storage Tanks, And Capable Of Providnig 4 To 20 Ma Analog Signal Compatiblewith Plc Signal Inputs And Completeas Per Working Requirements For Details Of Equipment Below. All Control Outputs To Mcc Panel Shall Be Included As Per Requierments. A ) .Fire Static Underground Tanksb ) .Real-Time Water Level Indication Monitoring 67 V. Low Level Audio-Visual Alarm At Less Than 25% Total Capacity.Raw Water Underground Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Tubewell Pumps At 35%Auto Cut-Out Of Tubewell Pumps At 95% 68 Auto Cut-Out Of Raw Water Pumps At 35%Domestic Water Underground Tanks Real-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Auto Cut-In Of Raw Water Pumps At 35% 69 Auto Cut-Out Of Domestic Water Pumps At 35% Flushing Water Underground Tanks At Stpreal-Time Water Level Indication Monitoringv. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity.V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Raw Water Pumps ( From Stp ) At 35% 70 Auto Cut-Out Of Flushing Water Pumps At 35% Domestic Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 71 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Flushing Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 72 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. 73 Providing Complete Testing Kit With All Chemicals Complete Suitable For Conducting Test On Water Quality.The Test Kit Shall Be Suitable To Measure Tds, Ph, Hardness, Iron Content And Other Parameters 74 Hydro-Pneumatic Pumping System For Domestic Supply To Fixture ( Toilet Kitchen ) : Providing, Fixing And Testing Of Packaged Type Skid Mounted Hydropneumatic System With Variable Frequency Drive Type Comprising Of : ( I ) Vertical, Inline Multistage Centrifugal Pumping Set With Stainless Steel Ss-304Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iecstandards And Gjl250 Cast Iron Suction& Discharge Casing, Connected To Tefc Ventilated Induction Motor Of2 Pole, 2900Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply. ( Ii ) Pressure Vessel Of Non Corrosivefrp Composite Construction Lined With Nsf And / Or Fda Listed Material, Likehigh Density Polyethylene With Fully Replaceable Polyurethane. Air Cell Burstpressure Of Minimum Of 5 Times The Vessel Operating Pressure And Cycle Tested For 2, 50, 000 Cycles. ( Iii ) Control Panel With Programmable Logic Controller ( Plc ) For Cyclic Operation Of Pumps + Variable Frequency Drive. The Pump Workingsequence Should Change After Every Operation.Contractor Overload Relays And Mcbs Should Confirm To Iec 898 – 1995 / Specifications. Blinking Indications For Pumps Start, Trip, Low Level Trip, Health Supply Should Be Provided In The Panel Along With The Ammeter& Voltmeter. Control Panel Should Also Consist Of Cooling Fan. ( Iv ) Pressure Switches Bellowtypefittedwithmicro Switch And Having Maximum Pressure And Differentialscaleshould Confirming Bs-6134 Standards And Ip55 Protection Class. ( V ) All Required Ball Valves, Non-Return Valves, Flexible Connectors Etc. And All Required Accessories, Heavy Duty S.S 316 Manifold To Make The System Completely Operational As A Skid Mounted System. Ball Valves Tobe Used Should Be Hot Pressed Brass Ot-58Withstainless Steelballand P.T.F.Eseal And O-Ring. Nrvs To Be Used Shouldbewithspringsando-Ring Arrangement. ( Vendor To Submit Performance Curves And Technical Catalog Of The Proposed Model For Review & Information ) Complete Manifold System Shall Be Factory Aasembled & Totally Mounted On A Common Base Frame With Following Duties:Note: Contractor To Note That The Suction Header Is Required To Have Inlet Connection From The Puddle Flange @ Water Tanks And To The Pump Suction. Provision Of Delivery Header Is Required To Have Outlet Connection From The Pumps. Suitable Outlet Flanges From The Delivery Mainfold / Header Shall Be Provided As Required.A.For Domestic Water Supply For Club & Benquet Hall: No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 350 Lpm Each Pump Head: 55 Meters Apx. Hp ( Motors ) : 3 Hp Location : Plumbing Plant Room 75 For Flushing Water Relift Pump :No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 250 Lpm Each Pump Head: 55 Metersapx. Hp ( Motors ) : 2 Hplocation : Stp Plant Room 76 Garden Hydrents & Floor Washing Relift Pump:Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty:No. Ofpumps :2 ( 1 Working +1 Standby ) Capacity: 200 Lpm Each Pumphead: 45 Metersapx. Hp ( Motors ) : 4 Hplocation : Stp Plant Room 77 Supply, Installation, Testing & Commissioning Of Continuous Duty Submersible Centrifugal Non-Clogging Drainage Pumps Of Efficiency Of Approved Make Complete With 3 Phase Motor With All Necessary Protection And Mechanical Seal Etc. Complete With All Ancillaries Including Float Type Level Controllers, Electrical Control Panels Fabricatd From 14 Gauge Crca Sheet Volt Meter Ammeter With Selector Switch, Tpmcb, 5 Va Cl : Cts, Phase Indicating Lamps Protected By 2 Amp Sp Mcb, Dol Starter, Necessary Wiring, Cable Alleys, Earthing, Interlocking, Starter With Automatic Float Type Level Controller, Providion Of High Level Alarm, Sequence Timer, Potential Free Contact To Starter For Connection To Bas, Both Pumps May Run Simultaneously At Pre Determind Level. ( 1 Working + 1 Standby ) Vendor To Submit Proposed Pump Model With Duty Curve.A ) . For Wtp & Stp Plant Room Drainage :Flow Rate : 450 Lpm Head : 15 Mtssolid Handling : 100 Mmlocation : Sump Of Basement Purpose : Plant Room & General Area Drainage Moc : Ss Body Ss Impeller & Shaft 78 B ) .For Basement Drainage : Flow Rate : 450 Lpm Head : 15 Mts Solid Handling : 100 Mmlocation : Sump Of Basement Purpose : Basement Area Drainage Moc : Ss Body Ss Impeller & Shaft 79 C ) .Manhole Cover For U.G Tanks And Sumps :Supplying And Fixing C.I. Cover Without Frame For Manholes :560Mm Diameter C.I Cover ( Heavy Duty ) The Weight Of The Cover To Be Not Less Than 108Kg. 80 F ) .Providing And Fixing Stainless Steel Ladder, Wall Mounted Of 4M Height ( App ) For Underground Tanks Complete With Flanged Ends And Inserts ( Removable Type ) Made Of 38Mm / 42Mm Dia 16 G S / S 304 Quality Pipe Made As Per International Quality Standards Of Approved Shape And Size With Non Skidding Stepsat 300Mm Vertical Spacing, Completeas Directed By The Engineer In Charge. 81 Water Treatment Plant: Providing & Fixing Vertical, Inline Multistage Centrifugalpumping Set ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) With Stainlesssteel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibration Elimination Pads Etc. Complete With Base And Frame, Nuts And Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Have Following Duty:A ) .For Club Building Only : No. Ofpumps: 2 ( 1 Working + 1 Standby ) Flow Rate :150 Lpm Each Head : 30 Mtsrequired For : Filter Feed Pump In Plumbing Plant Room ( 1Working + 1Standby ) 82 Providing And Fixing Vertical Pressure Filter With Dual Media Filter ( Comprising Of 600Mm Bed Depth Of Graded Sand Gravel And 600Mm Bed Depth Of Anthracite ) Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge : 150 Lpm Filtration Rate: 17500 Lit. / M2 / H Discharge : 150 Lpm Suggested Dia App.: 0.90 M 83 Activated Carbon Filter ( Domestic Water ) : Providing And Fixing Vertical Activated Carbon Filter Comprising Ofactivated Carbon Filter Media Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Epoxy Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge :100 Lpm Filtration Rate: 15000 Lit. / M2 / H Suggested Dia App.: 0.60 M 84 Providing, Fixing, Testing & Commissioning Of Msep Water Softening Plant ( Suitable For 3 Kg / Sqcm Workingpressure ) Complete With Initial Charge With T-40 Na Resin, Multiport Valve With Built In Ejector For Controlling All Operations ) , Regeneration System And Hdpe Tank, Pressure Gauge At Inlet, Outlet And Back Wash ( Each With Isolation Cock ) , Valves, Fittings And Water Hardness Testing Kit & Associatedworks. Softener Shall Be Suitable For The Following Duty:Note:The Successful Contractor Will Have To Carry Out A Test Of Raw Water From All The Sources Of Water For The Commercial, Residential & Apartment At Their Own Cost From A Reputed Lab As Approved By The Engineer-In-Charge / Consultant. On The Basis Of These Results The Contractor Has To Submit His Shop Drawings, Design Calculations And Specifications Accordingly.Please Note That It Is Ultimately The Responsibility Of The Contractor To Provide Treated Water For Different Use As Per International Standard As Given In The Attached Guidelines. Raw Water Hardness: 500 Mg / Ltreated Water Hardness:100 Mg / L Regeneration Period:12 Hrs.Capacity : 100 Lpm 85 Supplying, Installing, Testing And Commissioning Of Dosing System ( For Domestic Water Treatment Plant ) Consisting Of One Hdpe Tank Of 100 Litres Capacity With A Positive Displacement Diphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240 V / Single Phase / 50 Hz. Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers, Low Level Switch Andinjection Fittings. The Pump Shall Be Speed & Stroke Control Asialmi / Equivalent Make. The Cost Shall Be Inclusive Of Providing Salt For The Testing And Operation Of System Before Handover To The Owner. 86 Plumbing Panel: Design, Manufacture, Assembly, Wiring, Testing At Works And Supply To Site Of Following Panels / Distribution Boards / Switch Boards. The Boards Shall Be Designed And Fabricated As Per General Specifications, Technical Details, Specifications And Notes As Part Of This Tender / Boq And Relevant Bis Codes. ( Any Load Veriation In System As Technical Document Of Manifactureno Cost Shall Be Paid Extra For System Requirments ) Ip Rating: Ip 54 Incomer:1 No. 250 A 25 Ka, 3P Mccb Of Motor Duty - Only Magnetic Release. ( Adjustable Magnetic Release Upto 250A Mccb Or Micro-Processor Based Release Above 250A Mccb ) .Incomer Metering & Indication: A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt.B ) .R, Y, B Phase Indication Lamps ( 110V ) Led Type C ) .Cast Resin Metering CtS For Each Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio D ) .1 No. Digital Vaf + Pf Meter ( 110V ) ( *With / Without Rs 485 Port ) Bus Bars : 400A, Tp, Aluminium Bus Bars Of Electrolytic Grade With Heat Shrinkable Sleeves 25 Ka. Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) .B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer.C ) .110V Control Circuiting D ) .110V Control Supply Healthy Indication ( Led Type ) .Outgoings: A ) .Dol Starter Comprising The Following ( For Upto 2 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) . For 1Hp. ( 2 Nos. ) ( Chamical Dosingpump ) B ) .Type-2 Co-Ordinationc ) . 1 No. Suitable Rated Tp Mpcb, 10Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) . On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) .On / Off Push Buttons G ) Star-Delta Timerh.2 Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy & Of Suitable Burden & Ratio. J ) .Digital Ammeter K ) .On / Off-Trip / A / M Potential Free Contacts For Bmsl ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.B ) .Dol Starter Comprising The Following ( For 3 Hp To 5 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan :A ) For 4 Hp. ( 2 Nos. ) ( For Pump Room Exhaust Air Fan ) B ) Type-2 Co-Ordination C ) 1 No. Suitable Rated Tp Mpcb, 25 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) 2 Pole A / M Selector Switch For Bms Application G ) Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioh ) Digital Ammeter With Inbuilt Selector Switch I ) Digital Ammeter J ) On / Off-Trip / A / M Potential Free Contacts For Bmsk ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.C ) .Dol Starter Comprising The Following ( For 7.5 Hp To 10 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) For 7.5Hp. ( 2 Nos. ) ( Raw Water / Filter Feedpump ) B ) . For 6 Hp. ( 2 Nos. ) ( Soft Water Reliftingpump ) C ) .Type-2 Co-Ordinationd ) .1 No. Suitable Rated Tp Mpcb, 10 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) E ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contacts F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .On / Off Push Buttons ( With Lockable Off ) H ) . Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioj ) .Digital Ammeter With Inbuilt Selector Switch K ) On / Off-Trip / A / M Potential Free Contacts For Bms L ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. D ) .Star-Delta Starter Comprising The Following ( For 12.5 Hp To 25 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) .12.5 Hp. ( 3 Nos. ) ( Tubewells Pump ) B ) .Type-2 Co-Ordinationc ) .1 No. Suitable Rated Tp Mpcb, -----Ka, Without Inbuilt O / L Relay ( Only Magnetic ) D ) .Suitable Sized 3P Contactors ( Star, Delta & Run Contactors ) With 2 No & 2 Nc Auxiliary Contactse ) Suitable O / L Relay With Inbuilt Spp F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .2 Pole A / M Selector Switch For Bms Application H ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioi ) Digital H Inbuilt Selector Switch J ) On / Off-Trip / A / M Potential Free Contacts For Bms K ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. Feeders ( Without Starters ) For Hydronumatic Pump Panels :1 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 10 Hp Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For Sump Pump Panels : 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 15 Hp Sewarage Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For R.O Water Booster Pump Panels : 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 3 Hp R.O Waterbooster Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Spare Starter Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Starter Feeders:5 Hp Motors, Dol Starter ( 2 Nos. ) ( Spare Feeders ) Spare Motor Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Feeders: 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 10 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 5 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Vendor Can Also Consider Integrated Total Co-Ordinated Starter Upto 15Hp.Plumbing Panel As Described Above. 87 Sump Pump Panel ( Upto 5.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. 3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .E ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( Upto 5.0Hp Motors ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 88 Sump Pump Panel ( For 7.5Hp To 10.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. B ) .3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.C ) .R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.D ) .Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( For7.5Hp To 10.0Hp Motor ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering Oneach Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 89 Sewage Treatment Plant:Sewage Treatment Plant Based On Mbbr ( Moving Bed Bio Reactor ) Technology :Supply, Installation, Testing And Commissioning Of Package Type Pre-Fabricated Sewage Treatment Plant Based On Mbbr Technology ( Moving Bed Aerobic Bio-Reactor ) Of 65 Kld Capacity Including All Ms Structure, Mechanical, Electrical And Instrumentation Works As Per Technical Specification Mentioned In The Document. The Scope Shall Also Include To Provide The Ss Bar Screen In Grit Screen Chambers, Grease Separator, Primary & Secondary Treatment Of Waste Water, Air Blowers, All Necessary Interconnecting Piping & Valves, Pumps, Dmf And Acf Filters, Chlorinator, Ultravoilet Dis-Infection Unit, Mcc For Operation Of All Motors, All Inter Connecting Power And Control Wiring, Level Controllers & Other Controls, Ms Puddle Flange ( Hot Dip Galvanized After Fabrication ) , Inlet, Outlet, Overflow, Vent, Manhole Cover Etc, Completed In All Respect In Ready To Use And Easy To Transport Condition. ( The Entire System Tobe Installed Above Ground ) .A ) .Nature Of Effluent - Domestic Sewage From Toilets / Kitchen.B ) .Flow Rate - 65 Kld C ) .Sewage Incoming Characteristics D ) .Ph - 6.5 - 8.5 E ) .Bod5 - Upto 250 - 400 Mg / L F ) .S. Solid - 250 To 450 Mg / Lg ) .Cod 5 - Upto 600 Mg / L H ) .Oil & Grease - 50 Mg / L I ) .Effluent Discharge Standard After Treatment J ) .Ph - 6.5 - 7.5K ) .Bod5 - Less Than 10 Mg / L L ) .S. Solids - Less Than 10 Mg / L M ) .Cod - Less Than80 Mg / L N ) .Oil & Grease - Less Than 5 Mg / L Sewage Treatment Plant Shall Include The Following Items:A ) .Oil & Grease Chamber B ) . Sewage Equalization Tank C ) .Mbbr Tank ( Moving Bed Bio Reactor ) D ) .Tube Settling Tanke ) .Sludge Holding Tank F ) .Chlorine Contact Tank G ) .Filtration Through Mgf, Acf, Chlorinator & Uv Sterlizerh ) .Air Blowers, Pumps & Equipmenti ) .Filter Pressj ) .Piping, Valves Etc K ) .Electrical Panel & Cablingl ) .All Piping, Valves & Level Indicator / Controller Etc. Within Plant Room. Note: A ) .Contractor Shall Ensure Submission Of Detailed Civil General Arrangement Drawings ( Plan & Section ) , P & I ( Programming & Instrumentation ) Diagram, Schematic Diagram For The Above Mention Component & Additional Component Such As Inserts, Puddle Flanges, Vent Pipes Etc. If So Required For The Complete Working Of The Stp And Got It Approved By The Engineer In Charge. B ) .Only Plateform For Stp Plant Shall Be In The Scope Of The Owners. The Sewerage Treatment Contractor Shall Co-Ordinate, Supervise And Get All The Inserts Installed. All Supply Of Ms / Insert Plates Shall Be In The Scope Of The Sewerage Treatment Contractor.Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) C ) .Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) D ) .Supply, Installation, Testing And Commissioning Of The Following Tanks And Chambers In Hdpe / Pvc As Per Approved Drawings And Directions Of Engineer Incharge. The Cost Shall Include All The Required Mswalking Platform, Handrail, Staircase, Manhole Cover Etc. All Above Quoted With Minimum 10Mm M.S Tanks With 5Mm Frp Coating Protectiona ) .Mbbr Tank Of Capacity 25000 Litersb ) .Tube Settler Tank Of M Sc ) .Sludge Holding Tank Of Capacity 5000 Litresd ) .Chlorine Contact Tank Of Capacity 10000 Litrese ) .Treated Water Tank Of Capacity 15000 Litres Quoted With Minimum 10Mm M.S Tanks And All Above Item As Per Design Requirments ( No Extra Payment Shall Be Paid ) 90 Supply, Installation, Testing & Commissioning Of Horizontal Type Pumps, Having Cast Iron Body, C.I. Impeller & Shaft Connected To Tefc Motor For 415 Volts, 3 Phase, 50 Cycles A.C. Power Supply Withmechanical / Gland Seal. Protection Complete In All Respects Including Suction And Delivery Headers With Upvc Pipe Of Required Dia, Isolation Valves, Nrv & Pumps Shall Have Following Duty: A ) .Raw Sewage Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 40 Mm Size ) Set Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 2.5 Lps ( Required- 2.5M3 / Hr ) Head - 10-12 Mtr.H.P.-2 Hp Approx. 91 B ) .Submersible Sewage Lifting Pumpset Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 1.5 Lpshead - 10-12 Mtr.H.P.-2 Hp Approx. ( Solid Handling Capacity Upto 40 Mm Size ) 92 Supply, Installation, Testing & Commissioning Of Electromagnetic Type Flow Meter At The Outlet Point Of Raw Sewage Transfer Pump Of 50 Mm Size Suitable For 0 - 15 Klh Flow. 93 Supply, Installation, Testing & Commissioning Of Twin Type Rotary Air Blower With Acoustic Encloser, Driven Through “V” Belt Or Directly Coupled Through Flexible Coupling To A Tefc Motor Of Suitable Hp Suitable For 415 ± 10% Volts, 3 Phase, 50 Cycles A / C Supply. Capable Of Delivering 70 Cum / Hr Of Free Air At 0.5 Kg / Cm2. 94 Supply, Installation, Testing & Commissioning Of Air Piping Shall Comprise Of Pipes Droppers / Laterals With Ms ( Epoxy Coated ) Header Complete With All Fittings Such As Tees, Crosses, Plugs, Sockets, Elbows, Reducers, Supports & Clamps, Puddle Flanges Etc Including Cutting Holes In Wall, Makes Chases In Wall And Making Good The Same. Contractor To Submit Detailed P&I Indicating Their Proposal. 95 Supply, Installation, Testing & Commissioning Of Fine Air Diffusers Capable Of Delivering 10-12 Cum / Hr In Mbbr Tank For Providing Areation. 96 Supply, Installation, Testing & Commissioning Of Coarse Air Diffusers Capable Of Delivering 3-6 Cum / Hr In Equalization Tank And Sludge Holding Tank For Providing Areation. 97 Supply, Installation, Testing And Commissioning Of High Surface Area @ 400 M2 / M3 At Least Ring Type Media To Be Used For Bacterial Growth Installed In Moving Bed Bio Reactor Tanks. 98 Supply, Installation, Testing And Commissioning Of Pvc Tube Deck Settling Media To Be Installed In Tube Settling Tank. The Media To Be Supported On Msep Frame With Baffle Plate & Overflow Launder. 99 Supply, Installation, Testing And Commissioning Of Single Stage Horizontal Centrifugal Self Priming Pump With With C.I Body, Bronze Impeller, Shaft Of Stainless Steel, Shaft Sleeve Of Chrome Steel And Delivery Casing In C.I With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415+ / - 10%Volts, 3Phase50 Cycles A.C. Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Sequence Running Controller, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Includingisolation Valves, Nrv & Vibration Eliminators On Both Suction & Delivery Side Of Pumps .Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information. A ) .Sludge Feed / Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 8-10 Mm Size ) B ) .Set Of Two Pumps ( 1 Working + 1 Standby ) C ) . Capacity- 1.5 Lpsd ) .Head - 10.0 Mtr. E ) .H.P.-1.5 Hp Approx. 100 Supply, Installation, Testing And Commissioning Of Horizontal Centrifugal Pumping Set With Cast Iron Body, Bronze Impeller, Shaft Of Ss And C.I. Base & Head With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415 + / - 10%Volts, 3 Phase 50 Cycles A.C Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Including Isolation Valves, Vibration Eliminators On Both Suction & Delivery Side Of Pumps And Nrv On Delivery Side Of Pumps Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information.A ) .Filter Feed Pumpsb.Set Of Two Pumps ( 1 Working + 1 Standby ) C ) .Capacity- 3.0 Lps ( Suggested And Quoted For 5000Lph ) D ) .Head - 30.0 Mtr.E ) .H.P.-3.0 Hp Approx. 101 Supply, Installation, Testing & Commissioning Of Vertical Self Supporting Filtration Unit Fabricated From Ms Sheet As Per Is: 2825 ( Minimum Thickness Of Shell 8 Mm And Dished Ends 10 Mm ) Pressure Gauges, Sample Cock, Gi Class C Face Piping, Ci Butterfly Valves And All Accessories, With Initial Charge Of Filter Media Including Anthracite, Painting Inside With Epoxy Paint And Outside With Two Coat Of Red Oxide Primer And Two Or More Coat Of Synthetic Enamel Paint, Testingand Commissioning Complete.A ) .Mulitgrade Pressure Sand Filtercapacity - 5000 Lph Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm. Test Pressure : 4. 5 Kg / Sq Cm 102 B ) .Activated Carbon Filter Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm.Test Pressure : 4. 5 Kg / Sq Cm 103 Supply, Installation, Testing & Commissioning Of Metering Pump Type Chemical Doser With 100 Lits. Pvc / Hdpe Solution Tank, Injection Fitting Assembly, Suction And Delivery Hose Upto The Point Of Injection, Capacity 0-6 Lph, Complete In All Respects. 104 Supply, Installation, Testing & Commissioning Of Ultravoilet Dis-Infection Unit. The Unit Shall Have Over 99.9 % Bacterial Reduction From Inlet To Outlet. The Dis-Infection Chamber Shall Be Constructed Of Ss 316L On All Welted Parts. The Uv Lamp Shall Be Of Low Pressure Mercury Vapour Type With Hard Glass Enclosure, The Sockets Shall Be Water Tight & Vibration Resistant. The Lamp Life Shall Be Rated For 6000 Hours. The Unit Shall Be Complete With Temperature Safety Control, Lamp Out Alert Circuit & Uv Radiometer With 4 – 20 Ma Output. The Uv Unit Shall Have With Reactor, Cabinet Housing, Cabinet Cooling, Treatment Chamber, Electrical Panel, Temperature Safety Control, Lampout Alert, Uv Radiometer Along With Uv Monitoring System And Uv Monitoring Readout Panel.The Uv Dosage Should Be > 60, 000 Uw – Sec / Sq.Cm. The Lamps Should Be Selected Based Upon The Flow Requirement Of Respective Unit.Flow Rate : 5 Cum / Hr 105 Supply, Installation, Testing & Commissioning Of All Pipings ( As Described Below ) And Isolation Control Valves Including All Necessary Fittings And Clamps, Supports, Hangers As Required I / C Cutting And Making Good The Walls Wherever Required Complete In All Respects For Making The System Complete.A ) .Gi : Submerged Air Piping ( We Suggest Upvc. Gi Is Never Used For Submerged Piping ) Ms Epoxy: Air Piping & Pumped Effluent Riser ( Non-Submerged ) Upvc : Interconnecting Pipe Line After Delivery Header Of Pump / Filtercontrollers With Low Voltage Relays, Stainless Steel Probes And Pvc Shroud, Control Cabling As Required Length. ( No Of Probes As Required For Function Of Each Controller ) . 106 B ) .Filter Feed Pumps To Cut Off Duty Pump On Low Water Level In The Chlorine Contact Tank And High Water Level In The Treated Water Tank And To Start Pump At Low Water Level In The Treated Water Tank. 107 Supply, Installation, Testing & Commissioning Of Filter Press Of Plate Size 18X 18X 12 Nos. Plate With Screw Feed Pumps Of 5 M3 / Hr @ 40 M Head Capacity ( 1 Working + 1 Standby ) Complete In All Respects. 108 Providing Installing Testing And Commissioning Of Ultra Filteration ( Uf ) System For Further Polishing Treated Effluent And Capable Of Producing 5, 000 Litre / Hour. The System Shall Be Complete With Uf Feed Pumps ( 1W+1S ) , Backwash Pumps ( 1W+1S ) , Cartridge Filters ( Fabricated| ) , Uf Membranes Flushing / Cleaning System Complete Instrumentation For Automation And Monitoring Rotameters Pressure Gauges Interconnecting Pipeword Electrical Cabling And Switchgear, All Complete Electrical Installation For Stp 109 Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing And Commissioning Of Motor Control Centre Fabricated Out Of 14 Gauge Crca Sheet Steel. Cable Gland Plates Shall Be Provided On Top As Well As At The Bottom Of The Panels. Panels Shall Be Treated With All Anticorrosive Process Before Painting As Per Specifications With 2 Coats Of Red Oxide Primer And Final Approved Shade Of Powder Coated Paint. 2 Nos. Earthing Terminals Shall Be Provided For 3 Phase, 4 Wire, 50 Hz Supply System. Lifting Hooks Shall Also Be Provided In Case Of Large Panels. Approval Shall Be Taken For Each Panel Before Fabrication. Quoted Rates Shall Be Inclusive Of Cables ( In Accordance To Specification ) With Earthing From Panel To Each Motor / Equipment.Motor Control Centreincoming: A ) .200 Amps Tpn Mccb With The Following Accessories:B ) .0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.C ) .0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set. D ) .Pharse Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets. Bus Bar:A ) .200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing; A ) .10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For ‘On / Off / Trip’ Status Of Motor B ) .Spare 25 Amps TpnmcbS2 Nos. C ) .Spare 32 Amps TpnmcbS2 Nos. D ) .Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Mcc For All Stp Equipments / Pumps As Described Above.Notes : A ) .All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.B ) .All Motor Starters Shall Be Provided With Automatic Level Controller. C ) .Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors . Motor Control Centre Incoming 200 Amps Tpn Mccb With The Following Accessories:0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set.Phase Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets.Bus Bar 200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For‘On / Off / Trip’ Status Of Motorspare 25 Amps TpnmcbS2 Nos. Spare 32 Amps TpnmcbS2 Nos. Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Notes : All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.All Motor Starters Shall Be Provided With Automatic Level Controller.Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors .Provision Shall Be Made For Providing Potential Free Contacts To All Pumps Starters.Mcc For All Stp Equipments / Pumps As Described Above. Sub Total Of Part A 110 Part B ( O & M Cost ) ( For 5 Years ( 60 Months ) From Final Handing Over Of All Works. ) ( Optional ) Trained Operator To Operate The Stp Round The Clockincluding Operator And Regular Visit Of Supervisor. Perannum Including All Charges Like Amc , Monthly Charges Of Water Analysis And All Consumables Etc Included. Sub Total Of Part B ( Rate Only ) 111 Part:C Providing & Laying Upvc Pressure Pipes Of 6 Kg / Sq.Cm Pressure Rating Class 3 ( Is : 4985-2000 ) Including Fittings, Tees, Bends, Clamps, Coupling And Adaptors Supports, And Jointing With Solvent Joint, Testing And Necessary Earth Work In Excavation, Backfilling, Disposal Of Surplus Earth With A Lead Up To 100M Complete, Compaction And Consolidation Including Sand Bedding All Around Upvc Pipe & Fittings And Thrust Blocks At Bends As Per Standard Design.200Od 112 Constructing Rccchamber Of Holding Capacity 10 M3 With Grade Of M25 Including Cost Of Centering , Shuttering & Pcc Below Foundation In 1: 5:10 & 75 Mm Thick And Inside Chamber Of 75Mm Thick As Per Standard Design Including Inside Plastering With Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design .Rate To Include Cost Of Reinforcement , Excavation And Filling Of Earth. Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. The Contractor Has To Detect Different Unilities Like Sewer Line , Water Supply Line , Electrical Cable , Telephone Cable , Gas Pipe Line Etc. Using Utility Detecting Machine Before Start Of Excavation And Shall Start Excavation Only After Getting Permission Of Engineer In Charge.All Kinds Of Soil.Depth Upto 1.5M From Existing Ground Level 113 B ) Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 114 Providing & Laying Cement Concrete - All Works Upto Plinth Level : C ) 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 115 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . A ) Uptoplinth 116 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.B ) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 117 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : C ) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 118 D ) Suspended Floors, Roofs, Landings, Balconies And Access Platform 119 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 10 In Foundation And Plinth In: A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) For 230Mm Thick Brick Work 120 B ) 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 121 C ) 15 Mm Cement Plaster On Rough Side Of Single Orbrick Wall Of Mix:1:4 ( 1 Cement: 4 Fine Sand ) 122 D ) 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 123 Designing, Preparation Of Shop Drawings, Supplying, Erection, Testing, Commissioning Of All Mechanical, Electrical And Other Components Including Getting Approval Of Successful Test Results From Approved / Authorized Agency From Pollution & Environmental Authorities, Operating & Maintaining Upto Successful Commissioning, For 5 M3 / Day Capacity Sewage Treatment Plant Sewage Treatment Plant Near Workshop Area ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) Suprime / Sintex Maketotal C / F To Summary 124 R.O Water Treatmentplant: Supply, Installation, Testing And Commissioning Of R.O. Plant Capacity Of 750 Lph ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) For The Following Parameters And Consisting Of ( But Not Limited To ) The Following Main Components:- ( I ) Inlet Quantity : As Per Detailing ( Ii ) Output Quantity : 750 Lph ( Iii ) Inlet Tds : 600 Ppm ( Iv ) Outlet Tds : 75 Ppm ( V ) Inlet Hardness : 350 Ppm ) ( Vi ) Outlet Hardness : 50 Ppm ) Raw Water Pumps Of Horizontal, Centrifugal Type Suitable For A Flow Rate Of 1500 Lph At 25M Head. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Tefc Suitable For A Supply Of 415V / 3-Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundations, Bolts, Pressure Gauge At Inlet And Outlet Of Each Pump. -- 2 Nos. ( 1W+1S ) Special Antiscalant Dosing System Consisting Of One Hdpe Tank Of 100 Litre Capacity With A Positive Displacement Diaphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240V / Single Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers & Injection Fittings. -- 1 Set Micron Cartridge Filter Suitable For A Flowrate Of 1500 Lph To Achieve Particle Filtration Of Less Than 5 Microns. The Unit Shall Be Supplied Complete With Inlet And Outlet Branches Removal Cap For Replacement Of Element, Inlet And Outlet Pressure Indicators. ( One For The Pressure Treatment & Other For Cip System ) Moc: Polypropylene -- 2 Sets R.O High Pressure Feed Pumps Of Vertical, Multistage Centrifugal Type Suitable For A Flowrate Of2000 Lph At 14 Kg / Sq.Cm. The Pump Construction Shall Be Of Ss-316-L & Impeller Shall Be Also Ss-316-L. The Motor Shall Be Of Tefc Suitable For A Supply Of 415V / 3 Phase / 50 Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundation, Bolt, Pressure Gauge At Inlet And Outlet Of Each Pump.- 2 Nos.R.O. Modules Made Out Of Spiral Wound Thin Film Composite Suitable To Withstand Pressure Of 20Kg / Sq.Cm. Suitable Bspt / Npt Connections Shall Be Used For Connecting Feed & Reject Ends. The Modules Shall Be Supplied Complete With All Necessary Instrumentation, Valves For Sampling, Drain, Reject & Permeate, Epoxy-Coated Structural Steel Bases And Supports, As Per Following System Capacity Requirements: ( I ) Total Net Treated Water Output Of System = 750 Lph ( Ii ) System Recovery= 50 - 60 % ( Iii ) Filtration Area Per Membrane = 85 Sq.Ft. ( Iv ) Number Of Membranes = The Total Number Of Membranes Required Shall Beas Per Requirements, Supported By Calculations From The Vendor. Centralised Plc Control Panelalong With Touch-Screen Digitial Display Board Along With All Digital Sensors For Tds & Flow, Made Out Of Crca Sheet Min. 2Mm Thick Having Main Contactors For All Pumps ( Listed Above ) Including Spp, 3 Phase Thermal Overload Relay. The Control Panel For Monitoring And Control Of P.O. System Shall Include All Required Signal Lamps, Hrc Fuses, Annunciation Box With Hooter. All Control And Power Cabling Along With Double Earthing Between The Panel Shall Be Included In The Scope Of Supply Of The Contractor. An Emergency Stop Push Button Shall Be Provided In The Panel. The Mcc Panel Shall Have The Following Interlocks:- I ) High Pressure Pump Unit Trip In Case Of Low Suction Pressure. Ii ) High Pressure Pump Unit Trip In Case Of High Discharge Pressure.Iii ) Special Anti-Scalant Dosing Pump Trips In Case High Pressure Pump Trips And Vice Versa.Iv ) High Pressure Pump Trip In Case Of High Conductivity In Permeate.V ) Shc Dosing Pump Trips Incase High Pressure Pump Trips And Vice Versa. Vi ) Orp With Dump Valve.-- 1 Seti ) First Fill Of All Chemicals And Lubricants To Commission And Operate The Plants. --1Lotj ) All Interconnecting Piping Work With Valves:- I ) Low Pressure Side Till R.O. Feed Water Pump. Piping Shall Be Of Extra Strong Pvc And All Valves Shall Be Of Extra Strong Pvc And All Valves Shall Be Pvc Ball Valves. -- 1 Lotii ) High Pressure Side Piping From The R.O. High Pressure Pumps To The Reject Stream Control Valves Shall Be Of Ss - 304 Using All Ss Fittings Ball Valves Of Suitable Pressure Rating Shall Be Used Till 25 Mm Size, Above 25 Mm, Flanged Globe / Wafer Butterfly Valves In Ss Construction Shall Be Used. Rejects Pressure Control Valves Shall Be Globe Valve And Feed Flow Control Valve Shall Be Of Ss-304. -- Lotiii ) Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants. ( All For Above From A To J Complete ) 125 R.O Water Storage Complete 316 Stainless Steel Treated Water Storage Tank ( Double Wall ) Of Capacity 2000 Litres Including All Inlet / Outlet Connections, Accessories, Valves, Double Seal Manhole Covers, Insulation Etc.The Stainless Steel Tank Must Be Ozone Resistant And To Be Used As Ozone Contact Tank. Fabrication To Be Done As Per Approved Shop Drawing. ( Make :Nector ) 126 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank.. 127 Activated Carbon Filter ( Automatic Type For Online Installation Before The Micron Filters ) Suitable For A Flow Rate Of 1500 Lph. The Material Of Construction Shall Be Composite Frp. The Unit Shall Be Supplied Complete With Multi-Port Valves, Inlet And Outlet Branches Removal Caps Of Replacement Of Elements Inlet And Outlet Pressure Indicators. -- 1 Set 128 Hydropneumatic System For R.O Supply Providing Fixing And Commissioning Suitable Complete Composite Hydropneumatic System Consisting Ofhorizontal / Vertical Multistage Centrifugal Pump Having Stainless Steel Impellers, Stainlesssteel Shaft, Stainless Housing And Single Mechanical Seal And Pressurised Tankof Required Specifications And Of Non-Toxic Rubber Diaphragm, Complete With All Accessories Including Pressure Switch, Pressure Gauge And Electrical Panel With All Necessary Protection And Operational Devices I.E Alternate Pumping Operation And Shut Off During Dry Running Conditions Etc., And Inclusive Of Ss 316 Suction And Delivery Manifold Of Required Size With Non-Return Valve And Ball Valveand Withsuitableelectrical Motor To Be Operated On 210 / 220 Or 400 / 440 Volt 50 Cycle Suitable For Following Duty And With Total No. Of Pumps - 2 Nos. ( 1 Working+ 1 Standby ) Complete With The Approval Of Engineer-In-Charge.- Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants.A ) Discharge:150 Lpmb ) Head:45 M C ) App. Capacity Of Thevessel ( Frp ) : As Requiredtotal C / O To Summary 129 Hot Waterboilers And Other Related Accessories Electrical Hot Water Generators System With Solar Back Up.Hot Water Mixing Storage Tank ( 2 Sets For Club And Benquet Hall ) Supply, Installation, Testing And Commissioningof Solarwater Heating System Capable Of Generating 7500Lpd Of Hot Water Per Day At 60 Oc Along Withinsulated Horizontalhot Watermixing Tank Capacityand Design Code I.S: 2825 Fabricatedof 6 Mm Thick S.S. 304Plateand 10 Mmthickdishedend And Nozzles Complete With Inlet, Cold Waterinlet / Outlet Chain Connection Withflanges, Manhole With Bolted Cover With 72 Kw Electrical Back Up Along With Control Panels . Tankshall Beinsulated With 50 Mm Thickresin Bondedfibre Glass ( Density 24 Kg / Cum ) And Covered With500gpolythene Sheetand 24 Gauge Aluminumsheet Cladding Giving Proper Overlaps And Sealing The Joints With Suitable Adhesive Compound, Including The Following Additional Accessories / Specifications:Working Pressure : 7.5 Kg / Cm²i ) Safety Valveii ) Dial Type Thermometer Iii ) Thermowell For Thermostat Elements Cold Water Inlet Valve 80 Mm Dia Check Valve In Cold Water Inlet 80 Mm Dia.Hot Water Inlet / Outletsecondary Side 50 Mm Dia Valve Plate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Diaplate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Dia Hot Water Return Inlet 65 Mm Dia Drain Valve 50 Mm Diaair Release Valve 25Mm Diahot Water Return Nrv 65 Mm Dia Solar Pre Heating Working Inlet 80 Mm Dia Butterfly Valvesolar Pre Heating Working Inlet 80 Mm Dia Nrv Electrical Control Panel As Per Approved Apecification Temp. Controller 130 Hot Water Returnpumps For Domestic Waterprovidingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Dutynos : 2 ( 1 W +1 S ) Capacity: App.100 Lpm Head :15 M 131 Solar Hot Water Re-Curculation Pumps : Providingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Duty Nos : 2 ( 1 W +1 S ) Capacity: App100 Lpm Head :55 M 132 Electrical Panel Providing Motor Control Centres Fabricated From 16 Gauges M.S. Sheet With Powder Coated Finish. The Control Panels Should Be Comparable With H.P. Of The Motor As Specified.For Hot Water , Steam Genration Systemshot Water Recuculation Pumps, Hot Water Supply Pumps Condensate Pumps Etc.A ) One Incoming Main Isolation Mccb Of Required Rating.B ) Fully Taped Aluminum Bus Bar Ofrequiredcapacity In A Separate Bus Bar Chamber.C ) Isolation Switch Units With Mccbof Required Rating, For Each Unit.D ) Fully Automatic Dol Starter With Pushbutton And On / Off Indicating Lights For Each Unit, For Following Requirements:I ) Hot Water Boilers 2 Nos. Of Required 74 Kw Eachii ) Hot Water Re-Circulation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hp Iii ) Solar Hot Water Recirculation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hpiv ) One No. Spare Feeder Required 5 Hprotary Switches For Auto / Manual On / Off Operations For Each Unit.Rotary Duty Selector Switches.Panel Type Voltmeter 150Mm With Rotary Selector Switch For Reading Voltage Between Phases.Neon Phases Indicating Lights On The Incoming Mains. Single Phasepreventorfor Each Motor. Ct Operated Relayall Internal Wiring Colour Coded From Incoming Mains To Various Switchgear, Starter, Meter, Indicating Lamp And Bus Bar. All The Cable Entry To The Panel Shall Be From The Top. ( All For Above From Item ( A ) To ( L ) Complete Set ) . ( The Shop Drawing To Be Preparedand Approved Before Fabrication ) Total C / O To Summary 133 Swimming Pool Filteration System Recirculation Pumps Main Pool + Jacuzziarea : 550 M2 X 1.2 M Balancing Tank : 60 M3total Pool Volume : 660 M3 + 60 M3 = 720 M3filtration Flow Rate : 180M3 / Hr Filtration Plant With Pumpsupply, Instalation, Testing & Commissioning Of Bobbin Wound Side Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Fitted With Collector Arms And Diffuser Made From Unplasticised Pvc And Polypropylenewith Lid In Polyester Resin And Fibre Glass, Manual Air Purgeand 4 Pvc Flanged Connection For Inlet And Outlet, Pressure Gauge, Water Drain / Empty Drain For Filter Etc.Complete In All Respects. Including Corse & Fine Silica Sand Media For Filterapx. 7200Kgcapacity 60000 Ltrs / Hrdesign @30000 Ltrs / Sqm / Hr.Diameter1600 Mm Working Pressure4.0 Kg / Cm² 134 Valve Battery Valve Battery Manifold Made In Pvc With Flanges For Connecting To Filters Consists Of Set Of 5 - Buttterfly Valves For Carrying Out Filtration, Back-Washing, Rinsing And Shut Down Of The Filters. Size : 4 Inchsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) 135 Supply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) Capacity60000 Ltrs / Hrhead 16 Mtrhp 7.5, Three Phase 136 Swimming Pool U.V. Sterlizersupply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 60000 Ltr / Hrworking Pressure = 4.0 Kg / Sqm Uv Lamp Wattage = 400 W 137 Dosing Pumpsupply, Instalation, Testing & Commissioning Of Chemical Dosing Pumpfor Chlorination With 200 Ltrs. Sintex Tank And Accessories Capacity0-20 Litres / Hr.Head35 M 138 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 400X400 Mm 139 Inlet Nozzlesupply, Instalation, Testing & Commissioning Of Flow Adjastable Abs Inlet Nozzles Uv Treated With S.S. Screws To Fit In The 2 Pvc Pipes 140 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 141 Supply, Instalation, Testing & Commissioning Of Stainless Laddersteel 316 Ladders, Width: 500Mm Wide, Handrails Dia 43Mm Stainless Steel, Non-Slip Stepsprovided With Anchoring Socket.A ) 3 Step Standard Ladder With Anti-Skid Steps 142 B ) 4 Step Standard Ladder With Anti-Skid Steps 143 Underwater Led Lights Supply, Instalation, Testing & Commissioning Of 12Volt 54 W Under Water Stainless Steel 316L Led Light Fixture ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord. 144 Power Supply Supply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 145 Deck Box Supply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 146 Cleaning Accessories A ) Extensivetelescopic Handle, ( 2.4 - 4.8 ) Metres Long &1.1Mm Thick For Cleaning Attachment In Anodized Almunium. 147 B ) Transparent Blue Polyethylene Hose 40Mm ( 1-1 / 2 ) Dia 30 M Length. 148 C ) Surface Net Skimmer Made In Polypropylne 149 D ) Deep Bag Net Skimmer Made In Polypropylne 150 E ) Curved Polybristle Wall Brush 450 Mm 151 F ) Test Kit For Ph And Chlorine. 152 G ) Hi-Grade Stainless Steel Algae Brush - 10 153 H ) Vacuum Head With Ss-Body, 1 1 / 2 Connection Size 900 Mm Long 154 I ) Deluxe Large Vacuum Head With 4 Wheels, Alu-Body, Plastic Handle, 1 1 / 2 Connection Size 445X130 Mm 155 J ) Polybristle Wall Brush 10 ( 26Cm ) 156 K ) Chemical Tcca 90 ( 50 Kg. ) & Alum ( 30 Kg. ) 157 L ) Nylon Rope 158 Upvc Pipesproviding And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 159 B ) 50 Mm Dia 160 C ) 63 Mm Dia 161 D ) 75 Mm Dia 162 E ) 90 Mm Dia 163 F ) 110 Mm Dia 164 G ) 160 Mm Dia 165 H ) 200 Mm Dia 166 I ) 250 Mm Dia 167 Ball Valveproviding And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia 168 40Mm Dia ( Rate Only ) 169 50Mm Dia ( Rate Only ) 170 63Mm Dia 171 75Mm Dia ( Rate Only ) 172 90Mm Dia ( Rate Only ) 173 Butterfly Valve Providing And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required. A ) 90 Mm Dia 174 B ) 110 Mm Dia 175 C ) 160 Mm Dia 176 D ) 200 Mm Dia 177 E ) 250 Mm Dia 178 Non Return Valveproviding And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 50Mm Dia 179 B ) 63Mm Dia 180 C ) 75Mm Dia 181 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes.A ) 75Mm Dia 182 B ) 90 Mm Dia 183 C ) 110 Mm Dia 184 D ) 160 Mm Dia 185 E ) 200 Mm Dia 186 F ) 250 Mm Dia 187 Puddles Sleevesupply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia 188 C ) 50 Mm Dia 189 D ) 63 Mm Dia 190 E ) 75 Mm Dia 191 F ) 90 Mm Dia 192 G ) 110 Mm Dia 193 H ) 160 Mm Dia 194 I ) 200 Mm Dia 195 J ) 250 Mm Dia 196 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 300Mm Dia Pump Suction Header With 2 Nos 200Mm Dia Flange Connection For Balancing Tank To Pump Suction Header, 1 No. 90 Mm Dia Flange Connection For Vacuum Pipe & 1 No. 200 Mm Dia Flange Connection For Pool Drain Pipe & 4No. 200Mm Dia & 2 No. 160Mm Diaflange Connection For Pump Suction. 197 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 198 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 199 C ) 4 X 6 Sq.Mm ( Rate Only ) 200 D ) 4 X 4 Sq.Mm ( Rate Only ) 201 E ) 4 X 2.5 Sq.Mm 202 F ) 4 X 1.5 Sq.Mm ( Rate Only ) 203 G ) 3 X 6 Sq.Mm ( Rate Only ) 204 H ) 3 X 4 Sq.Mm 205 I ) 3 X 2.5 Sq.Mm ( Rate Only ) 206 J ) 3 X 1.5 Sq.Mm ( Rate Only ) 207 K ) 2 X 6 Sq.Mm 208 L ) 2 X 4 Sq.Mm ( Rate Only ) 209 M ) 2 X 2.5 Sq.Mm 210 N ) 2 X 1.5 Sq.Mm 211 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In 6 Gauge Gi Wire Recess For Loop Earthing As Required. 212 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. A ) 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 213 B ) 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 214 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 215 Electrical Control Panel Supply, Installation, Testing And Commissioning Of Following Swimming Pool Panel 415 V, 1 / 3 Phase And 50 Hz Power Distribution System. Thepanel Shall Be Free Standing Floor Mounting Sheet Metal Enclosed Dust And Vermin Proof Confirming To Ip-54, Compartmentalized Design Fabricated Out Of 16 Swg Sheet Steel, Painting Earthing Numbering, Danger Plate As Per Specifications And Drawings. Flush Front With Aluminium Busbars, Seperate Earth Bus Bars To Be Provided Throughout The Length Of The Panel The Incoming And Outgoing Feeder Breakers, Fuses, Indicating Lamps Etc Shall Be Accomadated In A Modular Multilier Arrangement. The Panel Shall Be Powder Coated Through 9 Tank Process. Adequate Size Cable Alley Shall Be Provided Forcable Termination.The Outgoing Feeders Inside Shall Be Connected Through Bus Bars / Flexible Cable Links. Incoming: One ( 1 ) No. 200A Tp 25 Ka Mccb With Thermomagnetic Digital Flush Mounted 0-200A Ammeter With 3 Way And Off Selection Switch With 3 Nos. 200 / 5 Amp Ct. 1 Set ( 3 Nos. ) Of Phase Indication Lamps 200A 25 Ka Tpn Aluminium Bus Bar. It Shall Be Insulated With Heat Shrinkable Sleeves And Shall Be Color Coded. Outgoing: Recirculation Pumpsix ( 6 ) Nos. Star Delta Starter Complete With Separate Single Phasing Protection Feature. On / Off Indicating Lamps, Relay, Contractors, Start / Stop Push Button, Auto / Manual Selector Switch, Sufficient Nos Of Potential Free Spare Contacts, Etc For Suitable Hp3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Chemical Dosing3 Nos. Toggle Switch For Doser3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Uv 3 Nos. Toggle Switch For Uv 1 Nos.16Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Underwater Lights 1 Nos. Toggle Switch For Led Pool Lightstotal C / O To Summary 216 Entry Water Bodypressure Sand Filtersupply, Instalation, Testing & Commissioning Of Bobbin Wound Top Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Non Corrosive Material, Complete With 6-Way 2 Multiport Valve With Filter Connection / Inter-Connecting Piping, Pressure Gauge, Water Drain / Empty Drain For Filter.Including Corse & Fine Sand Media For Filter As Per Approved Calculation Capacity15000 Ltrs / Hr Design @35000Ltrs / Sqm / Hr. Diameter750 Mm 217 Filter Re-Circulation Pumpsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Plastic Body, In Built Strainer Basket, Impeller In Ppo, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic / Graphite And Steatite, Motor Housing In Aluminium, Withmotor -2800Rpm, F Class Insulation, Protection Ip-55. ( 1W+1S ) Capacity15000 Ltrs / Hr Head 12 Mtrhp 2.0, Three Phase 218 Fountain Re-Circulation Pump Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp7.5, Three Phase 219 Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp2.0, Single Phase 220 Swimming Pool U.V. Sterlizer Supply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 20000 Ltr / Hrworking Pressure = 2.5 Kg / Sqmuv Lamp Wattage = 40 W 221 Chlorine Tablet Feedersupply, Instalation, Testing & Commissioning Of Chlorine Tablet Feeder With Accessories Capacity = 4.5 Kg 222 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 200X200 Mm 223 Fountain Nozzlesupply, Instalation, Testing & Commissioning Of Brass Crome Plated Gyserjet Nozzle With 1 Connection With Required Accessories. 224 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 225 Supply Of12volt 12W Under Water Stainless Steel 316 Ring Underwater Led Lightstype Led Warm White Light ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord.For Fountain Nozzle 226 Power Supplysupply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 227 Supply, Instalation, Testing & Commissioning Ofrgb Programmer For Led Lights. 228 Deck Boxsupply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 229 Upvc Pipes Providing And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 230 50 Mm Dia 231 63 Mm Dia 232 75 Mm Dia 233 90 Mm Dia 234 110 Mm Dia 235 160 Mm Dia ( Rate Only ) 236 200 Mm Dia ( Rate Only ) 237 Ball Valve Providing And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Ball Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia ( Rate Only ) 238 40Mm Dia ( Rate Only ) 239 50Mm Dia 240 63Mm Dia 241 75Mm Dia 242 90Mm Dia ( Rate Only ) 243 Butterfly Valveproviding And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required.A ) 90 Mm Dia ( Rate Only ) 244 110Mm Dia 245 160 Mm Dia ( Rate Only ) 246 200 Mm Dia ( Rate Only ) 247 Non Return Valve Providing And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required. 50Mm Dia ( Rate Only ) 248 63Mm Dia 249 75Mm Dia 250 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes. A ) 75Mm Dia ( Rate Only ) 251 90 Mm Dia 252 110 Mm Dia 253 Puddles Sleeve Supply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia ( Rate Only ) 254 50Mm Dia ( Rate Only ) 255 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 256 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 257 4 X 2.5 Sq.Mm 258 3 X 4 Sq.Mm 259 2 X 6 Sq.Mm 260 2 X 4 Sq.Mm ( Rate Only ) 261 2 X 1.5 Sq.Mm 262 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 263 Electrical Control Panelsupply, Installation, Testing And Commissioning Of 415 V, 1 / 3 Phase And 50 Hz Motor. The Switchboard Cubical Indoor Type Made Of 16 Swg Crca Sheet Painted With Powder Coated Paint Of Siemens Grey Shade. The Cubical Is Wall Mounted With Dust & Vermin Proof Construction With Inter Connection. It Comprise With The Following:A ) One Incoming Mains Of 63 Amps. Mccb – Tp, Schneider B ) One No. 0 – 600 V Digital Voltmeter, Mecon Make 96 Sq.Mm With Voltage Selector Switch. Make. C ) Three Phase Led Type Indicating Lights For Incoming Mains. D ) One No. Ct Operated 0 – 60 / 5 A Digital Ammeter, Mecon E ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light F ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light G ) Four No. Auto / Manual Selector Switches, Salzer Make H ) One No. Mcb Dp 6 Amps. For U / V System, Schneider Make. I ) One No. Toggle Switch For U / V System, Hsd Make. J ) One No. Mcb Sp 6 Amps. For Smps Dc Power Supply For Led Light, Schneider Make. K ) One No. Toggle Switch For Led Pool Lights, Hsd Make.Total C / O To Summary 264 Pond Aerationsupply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 1-3 Hp The Aerator Shall Be A Floating 265 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 5-7.5 Hp The Aerator Shall Be A Floating 266 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 267 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights Ss Frame And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 268 Miscellaneous Item ( Hanging Wire Etc ) Total C / O To Summary 269 Golf Course Water Bodies / Ponds Stpwater Supply:Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : A ) 25 To 40 Mm Nominal Bore 270 B ) 50 To 80 Mm Nominal Bore 271 Fixing Water Meter And Stop Cock In G.I. Pipe Line Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( Cost Of Water Meter And Stop Cock To Be Paid Separately ) . 272 Brass Fittings Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore 273 B ) 20 Mm Nominal Bore 274 C ) 32 Mm Nominal Bore. 275 D ) 40 Mm Nominal Bore 276 E ) 50 Mm Nominal Bore 277 F ) 65 Mm Nominal Bore 278 G ) 80 Mm Nominal Bore 279 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : A ) 15 Mm Nominal Bore 280 B ) 20 Mm Nominal Bore 281 C ) 25 Mm Nominal Bore 282 Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore Horizontal 283 Vertical 284 B ) 32 Mm Nominal Borehorizontal 285 Vertical 286 C ) 40 Mm Nominal Bore Horizontal 287 Vertical 288 D ) 50 Mm Nominal Bore Horizontal 289 Vertical 290 E ) 65 Mm Nominal Bore Horizontal 291 Vertical 292 F ) 80 Mm Nominal Borehorizontal 293 Vertical 294 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 295 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 296 25 Mm Nominal Bore 297 C.I. / Ductile Iron Pipes & Specialsproviding And Laying S&S C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc. ( Heavy Class ) : A ) Up To 300 Mm Dia 298 B ) Over 300 Mm Dia 299 Providing And Laying Flanged C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc., Suitable For Flanged Jointing As Per Is : 1538 :A ) Up To 300 Mm Dia 300 B ) Over 300 Mm Dia 301 Providing And Laying S&S Centrifugally Cast ( Spun ) Iron Pipes ( Class La ) Conforming To Is - 1536 :A ) 100 Mm Dia Pipe 302 B ) 125 Mm Dia Pipe 303 C ) 150 Mm Dia Pipe 304 D ) 200 Mm Dia Pipe 305 E ) 250 Mm Dia Pipe 306 Providing Lead Caulked Joints To Spun Iron Or C.I. Pipes And Specials, Including Testing Of Joints But Excluding The Cost Of Pig Lead : A ) 100 Mm Diameter Pipe 307 B ) 125 Mm Diameter Pipe 308 C ) 150 Mm Diameter Pipe 309 D ) 200 Mm Diameter Pipe 310 E ) 250 Mm Diameter Pipe 311 Providing Flanged Joints To Double Flanged C.I. / D.I. Pipes And Specials, Including Testing Of Joints : A ) 100 Mm Diameter Pipe 312 B ) 125 Mm Diameter Pipe 313 C ) 150 Mm Diameter Pipe 314 D ) 200 Mm Diameter Pipe 315 E ) 250 Mm Diameter Pipe 316 C.I. Sluice Valves / Fire Hydrants & Fixturesproviding And Fixing C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :A ) 100 Mm Diameterclass I 317 Class Ii 318 B ) 150 Mm Diameter Class I 319 Class Ii 320 200 Mm Diameter Class I 321 Class Ii 322 250 Mm Diameterclass I 323 Class Ii 324 300 Mm Diameter Class I 325 Class Ii 326 Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 327 Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 328 Constructing Masonry Chamber 120X120x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 329 Constructing Masonry Chamber 60X60x75 Cm, Inside In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Fire Hydrants, With C.I. Surface Box 350X350 Mm Top And 165 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 330 Air Valve & Water Meter ( Bulk Type ) : Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia 331 80 Mm Dia 332 100 Mm Dia 333 Providing And Fixing Enclosed Type Water Meter ( Bulk Type ) Conforming To Is : 2373 And Tested By Municipal Board Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :150 Mm Dia Nominal Bore 334 200 Mm Dia Nominal Bore 335 Providing And Fixing C.I. Dirt Box Strainer For Bulk Type Water Meter With Nuts, Bolts, Rubber Insertions Etc. Complete Conforming To Is : 2373 :80 Mm Dia 336 100 Mm Dia 337 150 Mm Dia 338 200 Mm Dia 339 Providingandlayings&Sc.I.Standardspecialssuitablefor Mechanical Jointing As Per Is : 13382 :Up To 300 Mm Dia 340 Filter Feedpump :Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty: A ) .No. Ofpumps: 3 ( 2 Working + 1 Standby ) B ) .Capacity :2000 Lpmc ) .Head :35 Md ) .Capacity :2000 Lpm E ) .Hp ( Motors ) : 75 Hp 341 Pressure Filter ( Domestic Water ) :Providing And Fixing Vertical Dual Media Pressure Filter ( Comprising Of Minimum 300Mm Bed Depth Of Anthracite And Support Media And Minimum Height On Straight 2500Mm ) Fabricated From High Performance M.S Plate Of Minimum 10Mm Thick For Shell & 12Mm Thickfor Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Internally Treated With Coal-Tar Epoxy, Complete With Air Scouring, Collection System Complete With Initial Charge Of Media, M.S Facepiping, Valves, Accessories, External Painting With 2 Coats Of Red Oxide Primer And Enamel Paint, Testing And Commissioning Complete. ( Tested To 5.0 Kg / M2 ) A ) .Discharge : App.120000 Lph ( Each ) B ) .Filtration Rate : 24, 500 Lit. / M2 / H C ) .Each Suggested Dia App.:As Per Manifacture Detail 342 Water Softener:Providing And Fixing ‘Cation’ Ion Exchange Water Softener Fabricated From Minimum 10Mm Thick M.S. Plateon Min. Shell And 12Mm Thick M.S. Plate On Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Complete With Initial Charge Of Filter Media And Ion Exchange Resins, Face Piping Accessories, Diaphragm Valves Of Approved Specifications, Hdpe Brine Tank Of Min. 500 Liters, Piping Testing And Commissioning Complete With Resins Of Approved Quality And Make And Regeneration Assembly Complete With Valves, Ejector, Brine Suction Valves And Piping. ( Bidder Must Indicate Type And Quantity Of Resin Used And Quantity Of Salt Required Per Regeneration ) . All Internal Parts Of The Softener Shall Be Rubber Lined As Per Approved Specifications.A ) .Minimum Expected Rate Of Flow:App.32, 000 Lph B ) .Total Soft Water To Be Produced Between Two Regenerations: App. 256 Cu.M C ) .Expected Raw Water Hardness : App. 450-500 Ppmd ) .Expected Treated Water Hardness: Less Than 5 Ppm ( Zero Commercial Hardness ) E ) .Max. Working Pressure: 4 Kg / Cm2 343 Cubical Panel Board - Plumbing : Supply, Installation, Testing And Commissioning Of Cubical Type Sectionalised Floor Standing Switch Board Of 31 Mva Fault Capacity At 415 V Complete With 3.5 Strip, 160 A Capacity Aluminium Bus - Bar Electrolytic Grade, Cable Alley, Switchgears Of Following Capacity & As Per Specifications.Incomer : 600 A Tp Mccb With Heavy Duty Solid Neutral Link With ( 0-100A ) Ammeter With 3 Ct And Selector Switch, ( 0 - 500 V ) Voltmeter With Selector Switch, Phase Indication Light Withprotection Fuse. - 01 Setoutgoings : I ) For 5 X 75 Hp Domestic Water Fixed Speed Hydroneumatic Pumps ( 1 Duty + 1 Stand By ) Ii ) For 2 X 5 Hp Sump Pump ( 1 Duty + 1 Stand By ) 150 A Tp Mcb With 40 A Dol Starter, Overload Relay, 96 Mm ( 0-40A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01Set. 40A Tp Mcb With 25 A Dol Starter, Overload Relay, 96 Mm ( 0-25A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01 Set.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
45.
Educational and Research Institute #8836836 Technical Bid
Establishment of State -of -Art Soil-Water Testing Facility and Service Centre -Purchase Goods , Particulars , Milliporewater Purifier: The System Should Produce Pure Grade Water Directly From Potable Water Feed. The System, Delivering Astm Type I And Iii Water, Can Be Directly Connected To The Available Potable Water Supply. System Should Contain Inbuilt Prefiltration Containing 0.5Um Filter, Silver Impregnated Activated Carbon ( To Avoid Bacterial Growth ) And Polyphosphate Granules Anti-Scaling Compound For Removal Of Hardness From Feed Water. System Should Include Reverse Osmosis With Conductivity Sensors Before And After The Membrane To Ensure The Quality Of Purification. Reverse Osmosis Should Have A Maximum Water Recovery Of Upto 20%. • Total No. Of Conductivity Cells In The System : Four Units • 3 – Way Solenoid Valve : 2 Units • Ro Reject Recovery Loop Available To Minimize Tap Water Usage. Recovery Upto 66%. • Rfid Tag For Automatic Traceability Of New Consumables In The System’S Memory To Ensure On-Time Reordering Of The Pre-Treatment Consumables, The System Should Have Automatic Warnings And Alarms Regarding The Water Quality.Type Iii Product Water Quality:, Ions Rejection : 97 To 98 % With New Ro Cartridge., Organics Rejection : > 99 % For Mw > 200 Dalton, Particulates & Bacteriarejection : > 99 %., Flow Rate : 8 Lt / Hr. The System Should Be Quoted With Proper Prefilter & Iron Removal Filter. Both Of These Have To Be Provided By The Same Company Who Manufactures The Water System.Prefiltration System:A Two-Stage Purification 5 Micron And 1 Micron Polypropylene Graded Density Wrapped Type Depth Filter With Low Voltage 20 Watts Powered Dc Pump With Noise Levels Of 50 Db Prefilter Should Be Attached With Tap Water. And• The Unit Shall Comprise Of Diaphragm Pump With Inter Connections And Built-In Pressure Sensor Ensuring Continuous Monitoring Of Cartridge Life.• System Shall Operate At Minimum Inlet Pressure Of 0.5 Bar And Maximum Of 1 Bar. • System Shall Deliver Water At The Outlet At A Minimum Pressure Of 2.6 Bar Till A Maximum Of 2.8 Bar.• System Can Handle Feed Water With Tds As High As 5000 Ppm And Sdi Upto 50.• It Protects The Water Purification System Downstream. Iron Removal Filter:The System Is Connected With Back Wash Able Iron Removal Filter To Deliver 0.1 Ppm Out Put. Feed Water Quality :-Potable Tap Water, Conductivity :< 2000 ?S / Cm., Ph : 4-10, Total Chlorine : < 3Ppm.Fouling Index : < 12., Feed Water Toc : < 2000 Ppb Pe Reservoir With Vent Filter: Blow Moulded Pe Reservoir With 50 L Capacity With Sensor Rod Float Switch With A Vent Filter To Resist Airborne Contamination Consisting With 0.65 Micron Filter, Activated Carbon And Sodalime For The Removal Of Particulates, Co2, N2 Etc.The System Produces Type I Water Suitable For Molecular Biology, Pcr, Hplc & Other Critical Applications. Type Igrade Product Waterspecifications: Resistivity:18.2Meg Ohm.Cm ( @ 25 Degree C ) , Toc : < 5 Ppb , Bacteria :< 0.1 Cfu / Ml , Pyrogen : <0.001Eu / Ml, Flow Rate : 2 L / Min, Particulates> 0.22U:<1 P / Ml , Rnase: <0.01 Ng / Ml, Dnase: 4 Pg / Ul Company Must Provide Ce, Cul, Valid Iso And Certificate Of Conformity. Warranty For A Period Of 12 Months From The Date Of Installation. The System Contains A Built-In-Dual Wavelength Photooxidation Uv Lamp ( 185 & 254 Nm ) . The Lifetime Of Uv Lamp Is Two Years. To Support Lifetime Of Uv Lamp, Original Literature From Company Is To Be Submitted Without Fail.There Must Be Minimum 200 Systems Installations In & Around Kolkata At Leading Depts. Of State Govt. Institute, Central Govt. Research Institutes, Industry In West Bengal.And Company’S Own Service Team Must Be Based In Kolkata. Engineers Should Be Well Trained By The Company Itself On Water Purification System. They Only Provide Service Whenever Needed. Suitable Filters Should Be Included Wherever Required. Suitable Distribution Pump, Booster Pump For Pumping Feed Water To The Main Unit From Storage Tank. Final Filter Is 0.22 Un. Prefiltration Cartridges Are To Be Supplied For One Year. In Case, The System Is Having Patented Technologies In It, Certificate With Patent Details Should Be Submitted For Proprietary Item. Systems Consumables Traceability Via Rfid Tag Technology. All Water Purification Cartridges And Point-Of-Use Filters Will Have A Built-In Rfid Tag To Ensure Proper Installation Location, Note Installation Date, And Track Volumes Of Water Passed Through The Purification Element. Supporting Documents Wherever Required And Original Catalogue Should Be Provided To Validate Specifications. To Verify The Above Technical Specification Provided Catalogue & Flow Schematic Must Match On Their Global Website For Quoted Model. , Microwave Digestionsystem : Microwave Digestionsystem Capable Of Simultaneous Processing Of Multi Reaction Vessels For Digestion All Kind Of Samples Using All Types’ Acids Including Hf Through Pressure Active Control On Reference Vessel With Pressure Rate Increase Control And Direct Temperature Control On All Vessels. Loading Of Vessels: Top Loading With Hardware And Software Safety Interlocks. Sample Vessels Should Be Inserted Individually From Top For Easy Sample Access. Cavity And Lid : Stainless Steel Construction With Heat-Bonded Fluoropolymer ( Pfa - Perfluoro Alkoxy ) Coating. System Control And Interface : Touchscreen Control, Inbuiltsoftware, Memory Formethodparametersanddigestiondata With Usb Interface, Software: Built-In Software Featuring Screen Display Of Temperature, Weight, Method Search, Power Profile, Method Set Up, Cook-Book Methods For Various Matrices, Graphic Display Of Routine Operations Etc. System Should Have Option To Operate Using Pc. Software Should Have Separate User Login And Admin Login To Secure Method Developed. Digestion Vessels: • Vessels Should Bemadefrommassive Tfm Or Ptfe-Tfm For Easy Handling.• The Rotor Should Have Capacity Of 16Or More Vessels To Run Samples In Same Batch / Run.• Volume Of Vessel Should Be 75Ml Or More• Vessel Operating Pressure Should Be High Up To 100 Bar Or Better• Vessel Operating Temperature Should Be Up To 2600 C Or More. Microwave Oven: • The System Should Have Poweroutput Of1500w Or More Using Dual Magnetrons 2000W From 2 Magnetrons ( 2 X 1000W ) • System Should Have Circularoven Forhomogeneousirradiation With Pfa-Coating For Corrosionprotection &Gas Collectionsystemforprotectionfrom Reactiongases. • Built-In Integrated Cooling System For Removal Of Gases ( Vapours ) And Cooling Of Vessel Without A Use Of External Chiller / Thermostat In Less Than 20 Minutes, Reaction Control:• The System Must Have Direct Temperature Control In Real-Time, Measures The Actual Sample Temperature In Each Individual Vessel Quipped With Floor Mounted Ir Sensors.• The System Should Pressurecontrolsensor For Reference Vesselinrealtime.• The Temperature And Pressure Sensors Supplied Should Be Maintenance-Freewithoutcable Connections. Temperature Measurement: Measurementrangeambient To 250Oc Or More, Pressure Measurement : Measurementrange0 To 40Bar Or Better, Contact-Free, Optical Sample Pressure Measurement, Safety Features : • Interlocks To Avoid Opening Of Vessels During Hot Condition • Release Of Over Pressure To Protect Vessels From Damage. • The System Must Have Automaticsafety Shut-Down Atoverheat / Overpressure. Safety And Emc Emissions Compliance Warranty Details: One Year Standard On-Site Warranty From Date Of Installation , Input Power Supply: 230-240 V, 50 / 60 Hz , Centrifuge Machine : Microprocessor Research Centrifuges … • Centrifuge Rotors & Carriers Are Suitable For Use With Variety Of Falcon & Vacutainer Tubes, • Soft Touch Keypads For Fast And Accurate Setting Of Run Parameters. Basic Runs Are Easy With Setting Of Speed, Time, Temperature, Brake, Press Start Key And Compufuge • Brushless Induction Motor With Frequency Drive & Unique Automatic Rotor Identification Ensuring Accurate Speed Setting For Individual Rotors. Over Current Overheating Safety Cutoff Circuit Is Provided For Motor Protection. • Safety Lid Interlock On The Centrifuge Ensuring That The Rotor Does Not Run With Lid Open While The Lid Cannot Be Opened Unless Rotor Comes Complete Halt. • Max. Speed 20000 • Max. Rcf 37540 • Max. Tube Size 100 • Max. Capacity 400 • W X D X H ( Mm ) 400 X 500 X 440 Essential Features: • User Friendly Microprocessor Control With Led Display • Menu Driven Ten Programme Memory • Choice Of High Brake, Low Brake And Coasting • Imbalance Detector With Auto Cutoff • Safety Lid Interlock To Prevent Cover Opening During Centrifugation • Automatic Unique Safety Rotor Identification System • Speed Holding Accuracy 100 Rpm • Self- Diagnosis For Errors Four ( 4 ) Years On-Site Warranty From The Date Of Installation Iso 9001-2015 Certified , Environmental Shaker : Orbital Shaking Incubators Salient Features: • Brushless Induction Motor With Variable Frequency Drives Suitable For Continuous Operations• Step Less Variable Frequency Drive Ensures Gentle Shaking Start And Maintains Set Speed• Counter Balanced Mechanism For High Stability In Uneven Load Of Different Sized Flasks• Universal Shaking Platform To Accommodate Different Sized Assorted Flasks• Maximum Shaking Capacity – 9 Flasks X 2000 Ml• Powerful Fan Motor For Forced Air Circulation To Maintain Uniform Conditions Inside Chamber • Machine Filled Cfc Free Puf Insulation To Eliminate Void Pockets• Unique Design Of Thermal Barrier For Better Energy Efficiency• Heating By Long Ss Tubular Heaters• Additional Tray To Store Samples• Chamber Calibration Port On Side • Hermetically Sealed Compressor With Cfc Free Refrigerant ( Cis-24 Plus ) • Microprocessor Controller With 4” Lcd Display For Display Of Shaking Speed & Temperature• 9 Programes Memory• High Temperature Safety Cut Off & Alarms For High / Low Set Temperature• Electrical Circuit Breaker• Time Delay For Compressor Switch On ( Cis-24 Plus ) • Overload Cut Off Relay For Compressor ( Cis-24 Plus ) • Rounded Inner Chamber For Easy Cleaning• Attractive Door Profile• Weight Carrying Capacity Of Each Tray : 30 Kg Uniformly Distributed• Auto Door Closer• Smart Handle With Led Door Closure Indication• Four ( 4 ) Years On-Site Warranty From The Date Of Installation, Desirable Features: ( I ) Touch Screen Display ( Tft ) With Additional Features ( Ii ) Validation Protocol With Iq, Oq, Pq Documentation ( Iii ) Port For Calibration Probes / Safety Back Up Iso 9001-2015 Certified Temperature Range & Accuracy: 5 C To 60 C + 0.5 C, Internal Volume ( Liters ) : 215, Platform Size: 580Mm X 600Mm, Maximum Shaking Capacity ( Volume X No. Of Flasks ) : 100Ml X 49, 150 Ml X 33, 500Ml X 24, 1000Ml X 15, 2000 Ml X 9, Shaking Speed Range ( Rpm ) : 20 To 250, Shaking Ampiltude: 25 Mm, Internal Dimensions W X D X H ( Mm ) : 660 X 765 X 650, External Dimensions W X D X H ( Mm ) : 800 X 1150 X 1300, Temperature Control: Microprocessor With Pt- 100 Sensor, Display: 4 Lcd Screen, Large Size Display For Ease Of Reading, Power Failure Alarm: Audio Visual Alarm, Door Open Alarm: Audio Alarm In Case Door Open For Over One Minute, Temperature Variation Alarm: Set Temperature + 2 C, Audio Visual Alarm, Illumination: 8 Watts Fluorescent Tube, Internal Body Material: Stainless Steel - 304 Grade ( Standard Modelas ) , Stainless Steel- 316 Grade ( Gmp Models ) , External Body Material: Power Coated Crca Steel ( Standard Models ) , Satinless Steel – 304 Grade ( Gmp Models ) , Insulation ( Cfc Free Polyurethane Foam ) : 70 Mm Minimum For Body & 80 Mm For Door, Noise Level: Less Than 65 Db ( A ) , Recommended Voltage Stabilizer : Vs02, Warranty: Four ( 4 ) Years On-Site Warranty From The Date Of Installation , Precision Drier: Microprocessor Control Helps In Achieving Precise High Temperature With Forced Convection. • Technical Specifications ( Parameter Wise ) • Internal Dimension ( W × D × H Mm ) 450×400×450 • Chamber Volume ( Litres ) 740×618×630 • Temperature Range Rt+10 ~300 C • Temperature Accuracy 1 C • Display Resolution ±1 C • Timing Range 1~9999Min • Shelves ( Nos ) 2 • Power Consumption 1550W • Electrical Requirements 220V, 50Hz, Single Phase Essential Features • Microprocessor Pid Controller ( With Timing Function ) • Polished Stainless-Steel Chamber With Rounded Corners For Easy & Quick Cleaning • Uniform Distribution Of Air Temperature • Forced-Air Convection • Double Layer Glass Door, Larger Viewing Window Four ( 4 ) Years On-Site Warranty From The Date Of Installation Iso 9001-2015 Certified , 20 Kva Onlineups With Battery Back Up:Src 6000 Uxi Capacity 200Kva, Battery Bank Consists Of 32Nos, Battery Rake, 100 Ah Vrla Battery Exide, 120 Minutes Back Up, 3 Years Warranty , Uv-Vis Spectrophotometer: Microprocessor Based Uv-Vis Spectrophotometer With High Resolution Touchscreen Display, For Operation On 220V / 50Hz. ? Uv-Vis Spectrophotometer Should Have Operating Wavelength Range 190Nm To 1100 Along With On-Board Software For Instrument Operation. ? The Software Should Be Offered With User Friendly Software To Work In Scanning, Wavelength Program, Time-Drive, Rate, Quant, Scanning Quant Modes ? Spectral Bandwidth Should Be Variable From 0.5, 1, 2, 5 & 20 Nm Is Preferred ? Fully Optically Double Beam With Czerny – Turner Monochromator Design And Holographic Grating Of 1200 Lines / Mm With 0.2 M Focal Length Is Preferred. ? Light Source : Deuterium & Tungsten ? Detector – Silicon Diodes Is Preferred ? Scan Speed : Up To 12000 Nm / Min Or More ? Wavelength Accuracy : ± 0.1 Nm Or Better Is Desirable ? Wavelength Reproducibility : ± 0.1 Nm Or Better ? A Stray Light Of <0.01 %T 220, 340 & 370 Is A Must ? Photometric Noise Should Be Less Than 0.00005A Or Better ? Photometric Range : Minimum ± 4 A Or More ? Photometric Accuracy Should Be ± 0.002A Or Better ? Photometric Reproducibility : ± 0.001 Abs Or Better ? Baseline Stability Should Be Less Than 0.0003 Abs / H Or Better ? Cell ( Quartz ) – With Stopper – Volume – 3.5 Ml. – Pack Of 2 To Be Supplied Along With Instrument ? High Sensitivity Matched Pair Silicon Photodiode Detector ? 4 Usb Ports Or More For High Speed Pc And Printer Connectivity, Data Storage And Transfer Through Usb Pen Drive ? The Instrument Should Provide Network Access Via Wireless Connectivity. Data Can Be Transferred To A Pc Via A Network ? Large Sample Compartment Compatible With Wide Range Of Accessories. ? Must Supply One Pair Of 10Mm Path Length Quartz Cuvettes Of 3.5 Ml Volume As A Standard Supply ? The Instrument Must Be Under 3 Years On-Site Warranty From The Date Of Installation The Following Must Be Supplied Along With The Main Instrument: ? One Branded I3 Pc With Original Windows 10 Professional ? One Laserjet Printer Online 1 Kva Ups With 30 Minutes Back Up , Automaticnitrogen Protein Analyzer: A. Speed Digester With Scrubber Digester Unit, Digestion System For 6 Sample Tubes With Adjustable Ir –Heating And Tight Suction Module To Prevent The Escape Of Sulfuric Acid Vapors During Digestion. Robust Design With Stand-Alone Tube Holder Made From Stainless Steel. Complete And Ready-To-Use System Supplied With The Following: • Heating Levels 1 To 10 And Ir Heating Up To 580 °C • The Insulation Tube As Well As The Optimal Designed Heating Chamber Guarantees That The Sample Tubes Are Heated With Optimal Thermal Homogeneity • Sample Tubes 300 Ml ( Diameter 48 Mm ) With Constricted Condensation Zone, Glass Thickness Of 2.3 Mm For Sample Tubes • Tight Suction Module With Included Hose For Scrubber / Water Jet Pump.• Stand-Alone Rack• Water Jet Pump, Plastic• Fast Heat Transfer; Temperature Range 700C To 580 C • Sample Holding Capacity: At Least 6 Nos With 300 Ml• Tight Suction Module To Prevent The Escape Of Sulfuric Acid Vapors During Digestion.Scrubber Unit Environmentally Friendly Neutralization And Exhaust Of Aggressive Fumes, Which Arise During Kjeldahl Or Other Digestions.The System Should Have Following Features - • It Should Operate Without Water-Jet Pump • The Build In Membrane Pump Should Guarantee High Suction Performance Of 32 L / Min. • For More Sensitive Digestions The Suction Capacity Can Be Adjusted In A Typical Range Of 100 – 400 Mbar Below Atmospheric Pressure.• The Two-Step Gas Scrubbing System Consists Of A 3 L Neutralization Step And An Adsorption Step • The Scrubber Should Be Supplied Complete And Ready To Use. B. Automatic Distillation System With Ph Acid Base Titration The System Should Have Following Features - • Detection Range Of 0.02 – 200 Mg / N Or More• Steam Ramps Should Be Available• Naoh Pump• H20 Pump• 7-Inch Touch Display, The Intuitive Touch Screen Provides Fast Feedback And Enables Easy Process Handling.• Recovery Nitrogen:N: >98% With Digestion Process, N: >99.5% W / O Digestionprocess • Integrated Timer • Distillation Capacity ( 100% ) ~ 40 Ml / Min• Efficient Steam Distillation By High-Performance Steam Generator. Adjustable Distillation Power 10 - 100% • Operating Convenience: Compact, Modern, And Functional Design, Stand-Alone Unit Using Minimal Space, Easy-To-Use Keyboard, Clear Led Display• Tap Water Consumption ~ 1.2 L / Min• System Should Store Memory Of 80+ Methods • System Should Store Number Of Determinations Log• System Should Store Number Of Determination Results• Steam Performance -150 Ml / 5 Min, System Should Have Safety Features:• Protection Of Users From Burns At The Splash Protector ( Distillation Area ) , Which Is Hot During Distillation Due To Protective Door.• Prevention Of The Start Of A Distillation With The Protective Door Open And Stop A Running Distillation And The Dosing Of Reagents Immediately When The Protective Door Is Opened During The Process Due To Protective Door Sensor.• Prevention Of The Start Of A Distillation Without A Sample Tube Inserted Due To Sample Tube Sensor.• Prevention Of Electrical Shock During Maintenance With Service Door Sensor / Switch To Disconnect Electrical Power Immediately When The Service Door Is Opened.• Protection Of Glass Parts By Protective Shield ( Cover ) At Condenser Control:• Full Process Visibility, Visual Control, And Close Monitoring Of The Distillation Process Through Glass Splash Protector.• Full Visibility Of Dosing Pumps. • Distillation Area Should Be Visible To Make Method Development Or Trouble-Shooting Easier. • Warranty : 4 Years On-Site From The Date Of Installation ( For Whole Set Up ) Should Have Proof Of Supply Of Atleast 3 Fully Automatic System With Inbuilt Titration.Iso 9001-2015 Certified , Quartz Water Double Distillation Set : Flow Rate: 2.5 Lit / Hr, Primary & Secondary Boiler: Demountable Quartz Boiler With Silicone O Ring Arrangement To Separate Primary Boiler From Secondary Boiler, Easy To Drain: Unit Has Drain Outlet At Bottom Of Primary Boiler For Removing Sediments, Tubing: Silicone Tubing 10Mmidx14mm Od, 10M Long, Power Required: 4.4Kw, 230V, Microbial Activity : Pyrogen Free, Conductivity: Conductivity < 1?S / Cm, Condenser: Quartz Condenser Inlet & Outlet Are At Top For Easy Maintenance Also Additional Cooling Condenser Is Provided At Centre, O / P: 2.5Lit / Hr, Lxbxh Cm: 35X35x100, Daps: Auto Cut-Off Has Buzzer Function & Reset Button, Third Party Test Reports: Govt Testing Certificate For Moc / Third Party Test Reports For Output Water Can Be Shared, Moc: Quartz Boiler And Quartz Condensers, Daps: Auto Off In Case Water Level Falls – Works With Level Sensor, Water Leveller: Sediment Drain Provision With Pinch Cock And Water Leveller Are Connected With “T-Joint” With Primary Boiler, Warranty Documents: 3 Years On-Site Warranty From The Date Of Installation Iso 9001-2015 Certified , Ph-Ec-Ion Meterwith Ionselectiveelectrodes: Specification For Benchtop Ion Meter With Ammonium & Nitrate Electrode Package: Meter Specification: Ise Range: 0.0001 To 19900 ; Resolution: Up To 3 Significant Digits ; Accuracy: ± 0.2 Mv ; Units: Ppm, M, Mg / L, %, Ppb, None; Calibration Points: Up To 5 Points; Calibration Edit: Yes Calibration Feature: Fix Calibration Errors Without Complete Recalibration; Temperature Compensation:-5 To 105 ?C Temperature Resolution: 0.1; Readout:Backlit Graphic Lcd Display; Splash-Proof Rating:Ip-54 Data Logging Point: 2000 Data With Date & Time St Power Input: 220 Vlt Ac Wall Adapter / Optional Battery Operated Facility. Stirrer : Automatic Stirrer Probe Facility Directly Controlled By The Meter. Warranty: 3 Years Replacement Warranty. Certification: Ce & Tuv, Ise Specification: Ammonium Electrode: Plastic Membrane Half Cell With Reference Electrode ; Range: 0.01 To 17000Ppm; Temp Range: 0 To 40°C Nitrate: Module Based Half Cell With Reference Electrode, Range: 0.1 To 14000 Ppm As N Temp Range: 0 To40°C Connector: Bnc Supply Should Include: Supply Should Include Main Benchtop Ion Meter With Electrode Holder & Stand, Nitrate Electrode With Replaceable Module, Reference Electrode, Respective Filling Solution Pack, 300 Ml , Nitrate 1000 Ppm Standard, Suppressor Solution For Ground Water Sample & Isa Solution For Surface Water Sample.And Ammonium Half Cell Electrode With Reference Double Junction Electrode And All Their Respective Filling Solutions; Standards And Isa Solutions Along With Automatic Stirrer Probe Buffer Solutions For Measuring 1000 Samples Must Be Supplied Along With Electrode Warranty: 4 Years On-Site Warranty From The Date Of Installation . Certification: Ce & Tuv Ise Specification: Ammonium Electrode: Plastic Membrane Half Cell With Reference Electrode ; Range: 0.01 To 17000Ppm; Temp Range: 0 To 40°C Nitrate: Module Based Half Cell With Reference Electrode, Range: 0.1 To 14000 Ppm As N Temp Range: 0 To40°C Connector: Bnc .Supply Should Include: Supply Should Include Main Benchtop Ion Meter With Electrode Holder & Stand, Nitrate Electrode With Replaceable Module, Reference Electrode, Respective Filling Solution Pack, 300 Ml , Nitrate 1000 Ppm Standard, Suppressor Solution For Ground Water Sample & Isa Solution For Surface Water Sample.And Ammonium Half Cell Electrode With Reference Double Junction Electrode And All Their Respective Filling Solutions; Standards And Isa Solutions Along With Automatic Stirrer Probe Specification For Benchtop Ph / Conductivity / Tds / Salinity Meter: Ph Range:-2.000 To 20.000; Ph Resolution :0.001Ph Accuracy: ± 0.002 ;Mv Range:±2000.0 Mv; Calibration Features:Fix Calibration Errors Without A Complete Recalibration;Ph Electrode Type :Ph / Atc Triode. Conductivity Range:0.001 ?S To 3000 Ms; Conductivity Resolution / Accuracy:0.001 ?S / 0.5% Of Reading ±1 Digit For Conductivity, Tds & Resistivity; Compatible Cell Constant:0.001 To 199.9; Ph / Cond. Calibration Points:Up To 5 Points; Cond. Electrode Type:Dura Probe Conductivity Cell;Resistivity Range / Resolution:2 Ohm To 100 Meg – Ohm / 2 Ohms-Cm Resolution; Salinity Range / Resolution:0.01 To 42 Ppt Sea Water / 0.01 Resolution; Tdsrange / Resolution :0 To 200 Ppt / 4 Significant Digits; Tds Factor Range:Linear, 0.01 To 10.00; Stirrer Provision ( Optional ) :Direct Control Of Stirrer Probe With Meter. Ip Rating:Ip 54 Rated; Data Logging:2000 With Date And Time Stamp Including Auto Read Function; Power Supply:Universal, Ac Power Adapter, 100-240 Vacand 4 Nos. Aas Battery ( 800 Hrs. ) . Warranty: 3 Years Replacement Warranty , Certification : Ce & Tuv , Laboratory Petty Mechanical / Heating Devices A ) Magnetic Stirrer: • Speeds Range 150-1500 Rpm • Stainless Steel Hot Plate Model For Temperatures Up To 340 C• Ceramic Hot Plate Model For Temperatures Up To 500 C • Easy To Read Backlit Lcd For Display Of Set & Actual Parameters • Monitoring Of Set & Actual Temperature / Speed• High Accuracy Of Temperature Control With Embedded Duel Sensors• Advanced Stirrers With Microprocessor Technology• Constant Speed Even With Change Of Load / Voltage • Maintenance Free Brushless Motor• Scratch Proof & Excellent Chemical Resistance• External Temperature Probe For Control Of Fluid Temperature• Last Parameter Recall, Ideal For Repetitive Processes• Unique Safety Temperature Control System • Settable Safe Temperature Limit To Avoid Overheating• Residual Temperature Warning When Unit Is Switched Off For Operator Safety• Power 1050• Max. Stirring Quantity ( Water ) ( Liters ) 10• Stirring Paddle ( Ptfe Coated ) Q-20A ( 13 X 50Mm ) • Motor Rating Input ( W ) 18• Motor Rating Output ( W ) 10• Speed Range ( Rpm ) 150-1500• Speed / Temperature Display Lcd• Speed Display Resolution ( Rpm ) 1• Top Plate Material Ceramic Glass• Dimension Of Top Plate ( Mm ) 184 X 184• Heating Power ( W ) 1000 • Temperature Range Upto 500 C• Control Accuracy Of Heating Temperature 1 C• Residual Heating Warning Alarm Above 50 C• Control Accuracy Of Heating Temperature With Pt-1000 0.2 C• External Temperature Sensor Pt-1000• Dimension ( Wxdxh ) ( Mm ) 360 X 215 X 112• Protection Class Acc. To Din En60529 Ip 21Warranty: 4 Years On-Site Warranty From The Date Of Installation.B ) Water Bath: • Multipurpose Water Bath With Adjustable Double Line 12 Holes To Hold Different Size• Samples For Easy & Hygienic Heating. Technical Data With Parameter • Temperature Range Rt + 5 C _ 99 C• Temperature Stability +0.5 C• Tracking Alarm +2 C• Chamber Volume 15 Ltrs• Interior Dimension ( W X D X H Mm ) 450X300x110• Timing Range 1~9999Min • Remark Double Lines Six Holes• Electrical Requirements 220V, 50Hz, Single Phase• Power Consumption 1500W Essential Features:• Microprocessor Control With Timing Function• Digital Display• Audible And Visual Alarm For Over Temperaturewarranty: 4 Years On-Site Warranty From The Date Of Installation. C ) Willy Mill Grinder: • ¼ Hp, Chamber Size 40Mmx25mm ( Cast Steel Chamber ) D ) Microwave Oven • Convection, Microwave, 28L Capacity, 1400W E ) E-Burette: Fully Motorized, Touch Screen Control Panel, , Pre Calibrated Dispensing Speed, Capacity 50Ml, Ptfe Piston For Good Chemical Compatibility, Spring Less Valve Assembly, Inbuilt Memory Dor 20 Reading, Computer Connectivity Option With Free Software, Rechargeable Battery, 5 No. Adapters Free Of Cost, Free Spare Usb Cable For Computer Connectivity, Battery Charger, Increment For 10Ml Capacity : 0.005 Ml 25 Ml Capacity : 0.01 Ml 50 Ml Capacity : 0.01 Ml Accuracy ( +, - ) 0.2% Cv ( +, - ) 0.07% Two Years Warranty , Nabl Certificate , Refrigerator : Frost Free Refrigerator With A Capacity Of 415 Liters, Double Door, Smart Inverter With Multi Storage Basket With An Energy Rating Of 4 Stars Or Better, 3 Years Warranty , Ac Machine : Split Type , Capacity Of Ac Units In Tonnage 1.5 With 5 Star Rating, !00% Copper, 3 Years Warranty , Flame Photometer: Microcontroller-Based Unit Designed To Provide Automation In Operation, Measurements And End-Result Presentation. It Can Do The Estimation Of Sodium ( Na ) , Potassium ( K ) , Lithium ( Li ) , Calcium ( Ca ) And Barium ( Ba ) In Single Aspiration Of A Sample. Specifications • Microcontroller Controlled Automation For Ease Of Operation.• Determination Up-To Five Elements With Single Aspiration ( Na, K, Li, Ca & Ba ) .• Unit Of Measurement “Ppm” And “Meq / L” • Suitable For Medical And Industrial Analysis• Calibration Standard Up-To Five Point.• Auto Ignition• Gas Leak Sensor• Auto Gas Cut-Off• Password Protection• Separate Login For Administrator And Guest• Data Processing With Linear Mode Or Quadratic Curve Fitting• Results Of A Measurement Taken Earlier Can Be Recalled And Displayed ( Max. Results Storage: 500 ) • Graphics Lcd Readout ( 240 X 128 Dot ) Lcd Readout For Adequate User Interfaces. • Built-In Real Time Clock For Date And Time.• Centronix Printer Port For Epson Compatible Dot Matrix / Inkjet Printers To Get Hard Copy Of Results ( Printer Optional ) .• Air Compressor With Built-In Air Regulator And Air Filter ( Systronics Model 126 ) .• Pc-Link Software ( Optional ) • Reproducibility: + 1% Fs + 2 Digits In Low Concentration Mode. + 2% Fs + 2 Digit In High Concentration Mode.• Curve Fitting Accuracy : + 2% Fs. ( High Conc. Range ) • Filters ( Regular ) : Na ( 589 Nm ) , K ( 768 Nm ) ; Interference Filters With 10-Nm Bandwidth• Filters ( Optional ) : Li ( 671 Nm ) , Ca ( 622 Nm ) , Ba ( 554 Nm ) Interference Filters With 10-Nm Bandwidth• Separate Channel And Separate Silicon Photodiode ( Detector ) For Each Element.• Minimum Sample: Approx. 3Ml. • Aspiration Time: Five Element Analysis Within 20 Second On Single Aspiration• Operating Air Pressure: 0.45Kg / Cm2 ( Typical ) , Regulated. *• Fuel Gas: Lpg ( Liquid Petroleum Gas ) , Regulated.**• Power Supply: 230V +10%, 50Hz.4 Years On-Site Warranty From The Date Of Installation Elements Minimum Concentration Without Dilution Maximum Concentration ( Without Dilution ) Low Concentration Mode Maximum Concentration ( Without Dilution ) High Concentration Mode Na 0.2 Ppm 10Ppm 100 Ppm, K 0.1 Ppm 10Ppm 100 Ppm, Ca 3.0 Ppm 100 Ppm 300 Ppm, Li 0.1 Ppm 2 Ppm 50Ppm, Ba 50 Ppm500 ( Minimum ) • Minimum & Maximum Are The Limit Of Calibration , Not Measuring Range Elements Serum Urine Bio-Fluids Na 0-200 Meq / L, 1 : 100 Dilution 0-250 Meq / L, 1 : 100 Dilution Upto 250Meq / L , With 1:100 Dilution, K 0-10 Meq / L, 1 : 100 Dilution 0-100 Meq / L, 1 : 1000 Dilution Upto 250 Meq / L, With 1: 100 Dilution, Ca ----- ( Note ) 0-10 Meq / L, 1 : 2 Dilution Upto 250 Meq / L , With 1: 100 Dilution, Li 0-2 Meq / L, 1 : 10 Dilution --------- Upto 250 Meq / L, With 1: 100 Dilution Specification For Compressor • Pressure : Power Supply : • To 1.0 Kg / Cm2 ( Maximum ) 230 V + 10 % • Weight : 6 Kg ( Approx. ) , Digestion Chamber With Heating: Specification Of Digestion Chamber 1 Dimension:1800Mm X 1000Mmx 1200Mm ( L X B X H ) , Working Space:1500Mm X 900Mm ( L X B ) 2 Fume Chamber Should Be Made Of Double Skin Construction Of Frp ( Fibreglass Re-Inforcement Plastic ) , Outside Should Besmooth Finished And Inside Of Fume Chamber Is Mat Finished.Inner Lining Of The F.C. Should Be Compressed Frp Sheet, Lined With F.R.Pof 5Mm Thick Biphenyl A Grade Fume Rate Resin. 3 External Finish Will Be With 1St Class Grade Pigment With Resign 4 Conceal Type Counter Balancing Door With Toughened Glass With Frp Framing 5 Casing Of The Blower Should Be Made Up From Frp. Motor Wattage 0.75Kw, 415V, 3000 / 1420Rpm, Tefc , Type Mn – 16 Dol 415V, 3Phase On / Off Push Bottom Starter 6 Standard Ducting System Of 200 Mm Dia ( 8” ) . Pvc-Rigid Duct.10 M Duct Free With The System. 7 Impeller Of The Blower Should Be Made Up From Frp. 8 Surface Of The Fume Chamber Also Made Fromfrp , Also The Working Surface Is Fire Retardant . 9 The Fume Chamber Will Have Facilities To Mount 02 No. Service Panel With External Control To Operate The Gas, Water Outlet Within The Chamber, Electric Switches, 08Watt Led Daylight Fitted Inside The Chamber. Specification Of Digestion Chamber Fume Purification System Water Scrubber : Vertical Types: 1. Size Of The Water Scrubber Is1000x 800X 1400 ( Lx D X H ) . 2. Frp Make Water Tank Of Capacity 750Ltrs. 2 Nos. 3. Chemical Pump, Capacity- 85 Lpm, H.P. -0.5 1No. All Plumbing Work From Connecting Point. ( Source Of Water ) Specification Of Hot Plate 1.Rectangular In Shape. Body Is Fabricated Out Of Thick Mild Steel Duly Finished In White Powder Coating Paint With Mat Finished Colour Combination. The Hot Plate Made Of Cast Iron Precisely Machined And Smoothed Duly Finished In Heat Resistant Black Paint Is Firmly Mounted On The Body. Heavy Duty Heating Elements Are Securely Laid Under The Plate To Operate On 220 Volts, Ac , 50 Hz . Temperature Is Controlled By Three Heat Rotary Switch / Energy Regulator As Per Demand. Sizes : 36” X 18” Guarantee / Warrantee For All Components: 24 Months From The Date Of Installation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 21
West Bengal View Result →
46.
Educational and Research Institute #8825445 Technical Bid
Purchase , Particulars , Atomic Absorption Spectrophotometer ( Aas ) : Atomicabsorptionspectrophotometerwithgraphitetubeautomizer ( Gta ) , Flameautomizer ( Fa ) Andvapourgenerationassembly ( Vga ) , Unitforflame ( Airacetyleneandnitrousoxide-Acetylene ) , Chiller, Autosamplersforgtaandflame.: Technical Specification: Atomic Absorption Spectrophotometer: Computer Controlled With Built-Inflame Emission Mode, Wave Length Range: 180 – 910Nmwave Length, Sensitivity: Sensitivityatleast0.35Absfor5µg / Mlaqueouscopperstandardsolutionwithair – Acetylene Flame., Optics: Double Beamholographic Monochromator, Czerny Turner , Focallength: Atleast250mmfocallength, Resolution: 1800Lines / Mm, Slit Width: 0.1Nm, 0.2Nm, 0.4Nm, 1Nm, 2Nm & 5.0Nm ( Six Step Auto-Changer ) , Flame Atomizer: Alltitaniumor Equivalentburnerwithimpactbead / Flowspoiler, Premixdesign, Movement: Automatic Movementintothe Sample Compartment, Affect From Acids, Organic Solvent: Unaffected From Attacks By Acid Solution Or Organic Solvents ( E.G. Methylisobutylketone I.E. Mibk, Flame Alignment In Liquid Beam:Fullyautomatic, Optimizedwithmotorizedburnermountforverticalandhorizontalburneradjustment, Nebulizer:Highprecisionabletoprovidemanuallyadjustableuptakeratesmaterialofthenebulizerandrelatedventurishouldbeinerttoacidsolutionsandorganic Solventssuchasmibk, Flame Control: Computercontrolledignition, Gas Control: Computercontrolledwithoxidantandfuelgasesmonitoringtomonitorconstantfuel / Oxidantrationignition., Safety Function: Interlockingsystem To Preventignition, Essential Interlock Monitor: Burnertypeaswellasitspresenceinposition, Airselector, Flamesensor, Liquidtraplevel, Gassupplypressureandairsupplyanywhere Inthe Networkofgastubings Inthe System, Automatic Lamp Selection Function: Computer Controlled Hollow Cathode Lamp Selection And Alignment, Lamp Holder: Atleast8lampholderwithbuiltinpowersuppliesforhollowcathodelampsandelectrode–Lessdischargelampsorequivalent, Operating Parameter Setting: Automatic Setting, Read Out / Display: Displayfacilityforabsorbanceaswellasconcentration, Displayoferrorsorerrorcodes, Absorbancerangeat Least Upto 2.0 Abs., Scale Expansion: Scale Expansionatleastupto 100X, Integration Time: Integrationtime Shouldcoveratleast0.1To 60 Secondsrange, Measurement: Measurementsofmean, Rsdandcv, Backgroundonlymode, Integration Ofpeakheightandpeakareas.Accessories / Spares With Flame Aasystem, Vapor Generation Assembly: Shouldbecontinuousflowbasedhydride / Mercuryvaporgeneratorwithoptionofusingwithorwithoutaprogra, Mmable Auto Sampler Highly Automatic: After Pressing The Start Key, The Whole, Process ( Sampling, Reacting, Calibrating And Cleaning ) Will Be, Finished Automatically.High Sensitivity: The Sensitivity Of Most Elements Is Better Than 1Ng / Ml / 1%A. Sensitivity Of Arsenic Is Better Than 0.15Ng / Ml / 1%A.Rsd: Less Than 3% Measurement Time: The Single Measurement Will Take 25 To 35 Sec, Less Solution: Sample 2-2.5Ml ( Including Clean ) , Potassium, Borohydride 1-1.5Ml, Carrier Liquid 5-6Ml.Atomizer: Heated Absorption Cell ( Heated By Air-C2h2 Flame In Standard Carrier Gas: Ar Pressure: 0.32 Mpa, Consumption:70 Ml / Min, Power Requirements: 240 Vac, 50 / 60 Hz, Precision: Precisionofbetterthan Oratleast1%Atppblevelsofmercury, Arsenic Etc. Absorption Cell: Theabsorptioncell’Smaterialshouldhavenoeffectofthehighheatof The Flame Andthe Cellforthe Analysis Ofmercuryshouldbeofa Closedabsorptiondesign Flame Arrester: Flamearrestershouldbeprovidedinthetubewhichconnectsthe Assemblyto The Absorptioncell, Cell Design Holder: Thedesignofthecellholdershouldgiveafirmandeasilyadjustable ( Foralignment ) Mountingonthe Burnerhead. System Accessories: Complete Withnecessary Reagentbottles, Connectorsetc.Hollow Cathode Lamps: Arsenic, Antimony, Calcium, Chromium, Cobalt, Copper, Iron, Nickel, Lead, Manganese, Mercury, Tin, Zinc, Molybdenum. Air Compressor With Air Filter Or Equivalent Air Service Unit:Completewithpressureregulatorquiteinoperation, Necessarytubingandconnectorsandshouldmeettheairsupplyrequirements Of Aasoperation.Oil Free Pump: Oil- Free Pumpandmoisture Trap, Corrosion Resistant: Resistanttoacidic Vapourandthedrainvalve ( If Any ) Shouldbemade Of Stainlesssteelof Equivalentcorrosionresistantmaterial Nitrous – Oxide Gas Regulator: Nitrousoxidegasregulator ( Twostage ) Withheater, Withnecessarytubing’Sandconnectors.Necessarytransformershouldbeprovidedto Transformthissupplyto Therequirementsoftheheater.Theheatershouldworkon230±10Volts50hzacpowersupply.Acetylene Gas Regulator: Acetylene Gasregulator ( Twostage ) Withnecessarytubingandconnectors.Nitrogen Gas Regulator: Nitrogenregulator ( Twostage ) Withnecessarytuningsandconnectors.Graphite Furnace System, Graphite Tubeatomizer: Should Becomputercontrolledfullyenclosedgraphitetubesystemconsistingofstabilizedtemperature / Totalpyrolyticgraphite Plateform.Gassupplies: Provisionoftwogassupplies ( Programmeselectable ) Withindependentcontroloverthe Gassupplythroughthe Furnace.Heatingrate: Heatingrate Ofatleast2500°Cpersecond Coolingtime: Coolingtime20seconds Temperature Range: Temperaturerangeambientto 3800°Cor Morein 1°Cincrementsfeedbacksystem: Feedbacksystemforfurnacetemperaturecontrol, Interlocksforwater, Gas, Temperature, Furnacedoor, Graphitetubedamage Andmainspower.Temp.Programming Upto 20 Rdertemperatureprogrammingfacilitywithflexibilityofprogramselection, Ramptime, Gases, Gasflowandreadtriggerforeachtemperature Step.Control Computercontrolledwithappropriateprovisionforprintoutofthe Furnace Andsample Parameters Display Calibrationdata / Graphs, Temperatureprofiles, Signalgraphicsandthe Instrumentstatus. Memory Memoryshouldbe Ableto Storeatleasttwenty Fivenonvolatileprogrammes Chiller Cooling Mode: Compressor Cooling, Temperature Controller: Pid Controller, Temperature Range: 5°C – 35°C, Accuracy: ±1°C, Cooling Capacity: 1300W @25°C, Pump Pressure: =1.3Bar, Pump Flow: =15Litre / Min, Tank Volume: 8 Litre, Tank Material: Stainless Steel Ss304, Refrigerant: R134a Size ( W*D*H ) : 360*450*653Mm, Power Supply: Ac220v, 50 / 60Hz Dataworkstation Application Softwareprogram Facility With Multitasking Software Shouldprovidecompletecontrolofinstrumentwithinstrumentstatusdisplayanditsvariousaccessories. Provide Accurate And Reproducible Time Averaged, Integration, Non – Averaged Integration, Multi Level Calibration. Softwareshouldhandleinstrumentlinearabsorbancereading, Concentration, Oremissionintensity, Integrationtime, Built-Instatistics, Calibrationequationcontrol, Slopeofanalyticalcurveusingoperatorselectivecalibrationstandard Built-Ininterfaceforcomputerconnectionanduseofoptionalaccessories. Comprehensivequalitycontrolprotocolsfacilityincludingblank, Multiplequalitycontrolstandards, Qa / Qcaudittrailandcalibrationfailure. Computer System, Make Reputed Brand, Processor I5 -10Th Gen, Ram 8Gb Or Advance.Ssd 512, Monitor 19”Led, Operation Software: Preloaded Windows Xp Professional Operating System With Licensed Cd Or Better Msoffice2000standardwithmedia, Manualandlicensedcdor Better, Preloaded Antivirus With Latest Version Along With Licensed Cd Or Better Fume Hoodexhaust Fume Hood Made In Stainless Steel Chimney With Std 20Ft Ss304 Powder Coated Exhaust Pipe With Inert Centrifugal Blower 1400Rpm, Ac 230V, With Standard Fitting Installation Hardware For Installation. Operation Kit Standardoperationkitincludingallrequireditems, Tubings, Fittingsforstartup / Regularoperationofinstrumentsuchasgaspurificationsystem To Be Supplied With The System. Operation / Maintenance Manual Operation / Maintenance Manualforeachunit Analytical Manual Analyticalmanualincludingapplicationsforflame, Vgaandgraphite System Operation And Maintenance Training One Weektrainingto Beprovidedtotwo Scientiston Softwaretraining, Operation, Maintenance Andtrouble Shootingaspectsof Instrumentatthe Timeof Installation. , Air Conditioner : Split Ac With Inverter Swing Compressor: Streamer Discharge & Dew Clean Technology For Healthy Air Capacity 1.5 Ton: Suitable For Medium Sized Rooms ( 111 To 150 Sq.Ft ) 5 Star: Best In Class Efficiency Copper Condenser Coil: Better Cooling And Requires Low Maintenance Key Features- Cooling Capacity @ 43°C: 100%; Noise Level: 38 Db ( A ) ; Ambient Operation: 54°C Special Features: 15% Higher Iseer Compared To Base Iseer ( 4.5 ) Of 5 Star Ac; Patented Streamer Discharge For Healthy Air; Intelligent Eye To Adjust Cooling According To Human Presence; Triple Display ( Power Consumption %Age, Set / Room Temperature & Auto Error Code ) ; Dew Clean Technology That Cleans Indoor Unit Coil With A Press Of Button Refrigerant Gas: R32 Environmental Friendly - No Ozone Depletion Potential Indoor Unit, Outdoor Unit, Remote Control, User Manual, Warranty Card & Standard Installation Kit , Bod Incubator: Floor-Standing, Double Doors .Temperature Range 5°C To 80°C With Uniformity Of ±0.2°C @ 10°C. Microprocessor Pid Controller Delivers Superior Temperature Control Accuracy, Required For Precise Results. Features And Advantages Include Illumination Lamp, Caster Wheels For Easy Mobility, Digital Timer . 175Litres / 6.1Cft, External Chamber Ms, Internal Chamber Ss304, Solid Insulated Door ( With Glass & Without Glass ) W / Lock Door, Stainless Steel 5 Shelves Removable, Caster Wheels, Humidity System, Light System By Interior Illumination W / 3 Fluorescent Tubes, Timer 0-99 Hours For Regulating Cycles Illumination Condition, Rfid Enabled Door Locking System. Brand Name And Model Name Must Come In The Display. , Centrifuge: Max Speed: 15000 Rpm Speed Accuracy : ±1Rpm Or ±1 X G Temperature: -10°C To +40°C. Possibility Of Precooling During Standstill Rotor Type: Angle Rotor For Conical Centrifuge Tubes. All Rotors With Lid And Anti-Corrosion Coating Rotor Capacity: 8 X 50 Ml With Max. Rpm:~14000 Rpm 8 X 15Ml With Max. Rpm:~ 14, 000 Pre Selection Of Run Parameters In Terms Of Rpm Timer Range: Pre Selection Of Time From 30Sec. To 10 Hr. Or Continuous Set Time In Hrs:Min, Min:Sec, Or Continuous Mode Automatic Rotor Identification & Imbalance Sensor Low Vibration During The Operation. Extremely Low Noise During Operation ( <66 Db ) . With Microcontroller For Speed, Time And Temperature Motorized Lid Lock And Inter Lock Keys For Start, Stop And Lid Open Power Supply: 230 V / 50-60 Hz , Chns Analyser : Fully Automated Pc Controlled Elemental Analyser For Solid And Liquid Samples.The Analyzer Must Be Able To Simultaneously Determine The Elements In The Following Combinations: Chns, Or Chn, Or Cns, Or Cn, Or Nwithout A Need To Change Column Helium As Carrier Gas And Option For Argon As Carrier Gas In Chns Mode.Sample Weight Range: 0.2 Mg Of Organic Compound To 800 Mg Or More Inhomogeneous Soildetection Range: 0 To 100% For All Elements ( C, H, N, S ) With The Capability Of Measuringat Least 10 Mg Absolute Carbon In Chns Mode And More Than 50 Mg In Cn Mode Standard Deviation: ?0.1% Of Absolute. Lower Detection Limit Of < 50 Ppm For N , C And S With Thermal Conductivity Detector ( Tcd ) Dependingon Sample Weight. The Instrument Must Fulfil The International And National Safety Standards. For Safety Reasons, Theentire Instrument Including Furnaces Must Internally Operate On Low Voltage ( < 50 V ) . Large Dynamic Measurement, Range From 0.1 Milligram, Chemical Substance To1 Gram Inhomogeneous Soil, Best Analysis Results For Any Sample Matrix, Wide Variety Of Optional Configurations, Individually Extendible, Low And Tool-Free Maintenance, Low Noise Level, Low Total Cost Of Ownership, Integrated 120 Position Auto Sampler As Standard, Patented Ball Valve Forblank-Free Sample Transfer. Furnace System • Should Have Two Zone Furnace System, Separate For Combustion And Reduction With Independent Temperature Control For Each Furnace In Chns Mode. Easy Slide-Out Mechanism Of Furnace For Routine Maintenance Work. It Should Be Possible To Set Difference Temperature For Combustion And Reduction. • Controlled Furnace Temperature Should Be 1200 Deg C Or More. • Easy Ash Removal Without Change Of Combustion Tube By Means Of An Exchangeable Ash Crucible. Separation System • Combustion Gases In The Form Co2, H2o, N2 And So2 Are Separated By Means Of Single Temperature Programmed Desorption ( Tpd ) Column. Detector System • Oxygen Intrusion Free Thermistor Technology-Based Temperature Stabilized Tcd Detector For Measurement Of C-H-N-S-O Auto Sampler System • Integrated 50 Or More Position Automatic Sampler Having Capacity To Handle Upto 1000 Mg Sample In Each Sampler Holder Position Of Carousel Software • Should Be Windows Based And Should Have Operating Software With Automatic Calculation And Statistical Evaluation Of Sample Results, Automatic Leak Check, Sleep / Wakeup Function, Gas Stop, Service And Maintenance Support And Weight Transfer From External Balance. • All Instrument Functions Incl. Gas Flow And Pressures Must Be Digitally Controlled For Diagnosis And Trouble Shooting Via The Internet. Consumables: To Be Supplied With Consumables Enough For 1, 000 Sample Analysis In Chns / Cns Mode. Necessary Documents: - • Catalogue In Original. • All Technical Specifications Should Be Printed On The Manufacturers Catalogue / Data Sheet. , Compound Microscope : Compound Microscope ( 10X Eye Piece, Objective With Magnifying Powers 10X, 40X And 100X Oil Immersion Objective Lens ( Body - Monocular Die-Cast Body, Inclinable Upto A Horizontal Position ( 90° ) ; Focussing - By Coarse & Fine Focusing Knobs; Eyepieces - Huygenian 10X And 15X; Objectives - Hard Anti-Reflection Coated, Colour Coded Par Focal Achromatic 10X, 40X, 100X, Oil Immersion; Condenser - Built-In Sub Stage Condenser With Iris Diaphragm. Branded, Best Quality ) , Compoundtrinocular Microscope With Camera: Trinocular Head, Eyepiece: Swf 10X, U Plan Objectives Of 4X, 10X, 40X And 100X, Abbe 1.25 N. A. Condenser With Iris Diaphragm, Ceramic Coated Flat Top Stage, Co Axial Coarse And Fine Focusing, Led Or Halogen Illumination With Automatic Voltage Sending Power Supply, Digital Camera ( 5 Mega Pixels ) , Fire Wire Cable, C-Mount Adapter 0.7X And Image Analysis Software With 4D Experiment Ability. , Conductivity Bridge : Advanced Microprocessor Based Design. Brand Name And Model Name Must Come In The Display. Conductivity And Tds Modes. Automatic And Manual Temperature Compensation Auto Ranging. 0-20?S / Cm, 20-200?S / Cm, 200-2000?S / Cm, 2 – 20 Ms / Cm, 20-200 Ms / Cm, 200Ms / Cm -2000. Multi Point Calibration. Tds Conversion Factor From 0.40 To 1.00 Cell Constant Adjustable From 0.1 To 10.0 Temperature Coefficient Adjustable From 0 To 10% / °C Normalisation Temperature Adjustable From 15 To 30 °C. Bi Directional Rs232 Interface. Baud Rate Selectable From 1200, 2400, 4800 And9600. Single And Continuous Print Out Of Conductivity. Multiple Printout Types. Combinations Selectable From Sr. No., Cond / Tds, Date, Time And Temperature. Real Time Clock. Temperature Setting ( Manual Temperature Compensation ) . Calibration Report As Per Glp Requirements Lcd Touch Screen Display With Backlight. Memory Storage Of 100 Measurements. Data Logging Facility Up To 500 Results. Data Logging Interval Selectable From 5S, 10S, 20S, 30S, 1M, 2M And 5M. Temperature Calibration. , Compound Phase Contrast Binocular Microscope : Body: Binocular, Sturdy, Stable Base Body With Focus Adjustment Controls. Eye Piece: Paired, High Quality, Achromatic, Wide Field, System Complete With Illumination System Is Required. Objective: Three Objectives 10X, 40X, 100X. 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively.100X Should Have Numerical Aperture Of 1.65. Nose Piece: Revolving Nose Piece To Accommodate A Minimum Of Three Objectives With Click Stops. It Should Be Provided With Ribbed Grip For Easy Rotation Mounted On A Precision Ball Bearing Mechanism For Smooth And Accurate Alignment. Stage Uniformly Horizontal, Mechanical Stage Having Dimensions Of Length 140 Mm ( + / - 20Mm ) . The Stage Should Be Provided With Spring Loaded Slide Holder For Exact Positioning Of Specimen / Slide. The Stage Should Have Ball-Bearing Arrangement To Allow Smooth Travel In Transverse Directions I.E. 80 Mm ( + / -10Mm ) And Front To Back Direction, 50Mm ( + / - 10Mm ) . The System Should Have A Build-In Variable Light Source ( Illuminator ) . This Light Sourceshould Have A 50 W, 12 V Halogen Lamp. All Consumables Required For Installation And Standardization Of System And Microscopecover To Be Given Free Of Cost. , Desktop Computer With Accessories : Corei5-11400 Motherboard-Gigabyte H510mh , 16 Gb Ddr4 Ram, 512 Ssd, Key Board, Mouse, 19”Led Colour Monitor, Bluetooth, Cabinet, Branded Laser Printer. , Digestion Hood For The Laboratory : Internal Lining: Suitable Material For Hf Resistancelike Upvc Or Pp Internal Size ( 1600X675x1250 Mm : Wxdxh ) ± 10%Should Supply With Digital Face Velocity Meter Withalarm / Low Exhaust Indicatorcold Water Service Fixture ( Inlet And Outlet, Pre-Plumbed ) For Using Distillationunit Inside. Tri-Wall Construction For Maximum Robustness. U-Pvc / Pp Internal Chamber. Chain And Sprocket Sash Support System. Hood Lighting Is Pre-Wired. Lighting Is Electronically Ballasted, Energy Efficient, Instant Start. Typical Light Intensity On Work Surface Is >1076 Lux In Zero Ambient Conditions. U-Pvc Exhaust Collar Ensures Superior Chemical Resistance. One Gas Service Fixture-Pre-Plumbed Internal Electrical Connection: Two Number ( 5 / 15 Amp ) Socket Internal Light Fitting For Proper Illumination With External Switches Vertical Sash: Polycarbonate / Toughened Float Glass ( Acidresistant ) Removable Baffle / Suitable Mechanism For Easycleaning, Blower And Duct: Pp+Frp – 250 Mm Diameter Duct 20 Feet In Length 1 Hp Motor And Reputed And Standard Company ( Brand Must Be Mentioned ) , 600 Cfm Minimum Volume Weather Proof Pp / Motor Housing. Exhaust: Pp+Frp Exhaust Fan With Chemical Resistantimpeller System Will Be Installed In First Floor Of Laboratory Block. Stack Height Should Beat Least Three Meters Above Top Roof ( Two Storey Building ) Shaping Vanes Increase Airflow “Sweep” At The Critical Area Atthe Sidewall To Improve Containment, Especially When Laboratorypersonnel Walk Fast In Front Of The Hood. , Electronic Precession Balance : Maximum Capacity [ Max ] 200 / 2000 G Minimum Load 20 Mg, Readability [ D ] , 0.001 / 0.01 G Tare Range-2000 G, Repeatability ( Max ) 0.001 / 0.01 G Repeatability ( 5% Max ) 0.0005 / 0.005 G, Linearity±0.002 / 0.02 G Stabilization Time2 / 1.5 S Adjustment External Physical Parameters Levelling System Manual Display Lcd ( Backlit ) Delivery Components Balance, Weighing Pan, Weighing Pan Shield, Grounding Foot ×1, Foot ×3, Power Supply. Weighing Pan Dimensions 128×128 Mm Packaging Dimensions 470×380×336 Mm Net Weight-3.2 Kg Gross Weight 4.8 Kg, Protection Class Ip 43 , Communication Interface Communication Interface, 2×Rs232¹, Usb-A, Usb-B, Wi-Fi® ( Option ) Electrical Parameters, Power Supply , Adapter: 100-240V Ac 50 / 60Hz 0.6A; 12V Dc 1.2A Balance: 12 – 15V Dc 0.4A Max , Environmental Conditions Operating Temperature +10 — +40 °C. , Environmental Shaker :Environment Shaking Incubator : Salient Features , Programmable Logic Controller ( Plc ) , 4.3 Hmi With Colour Display And Touch Screen, Password Protected Operation. , Universal Platform To Accommodate Vanous Type Of Flask And Test Tube Rack Max ( 8X250ml ) .Electronic Capacitance Type Humidity Sensor , Direct Display Of Temperature And Humidity, Display Of Set Value And Process Value, Unique Air Flow System Ensures Even Distribution Of Temperature And Humidity, Precise Control Of Temperature And Humidity By Using Built In Pid Controller ( Auto Tuning Type ) , Forward And Backward Rotation Programs And Rpm 30-350, Maintenance Free Brushless Induction Motor, Variable Frequency Drive ( Vfd ) Permanently Lubricated Bearing For Noise Less Operation, Triple Eccentric Counter Balanced Drive Mechanism For Uniform Agitation, Castor Wheel For Ease Of Mobility Adjustable Levelling Jack. , Horizontal Autoclave : 1.Fully Automatic Micro Processor Based High Pressure, High Vacuum Autoclave For Sterilizing Material Including Agars, Sterilization Of Solution In Open & Closed Bottles, Disinfection Of Materials And Waste Decontamination. 2. Should Be Front Loading, Have Rectangular, Horizontal Chamber With Well Insulated Jacket, Chamber Volume Minimum 165 Lit. 3. Should Have Single Vertical Sliding Door To Have A Pass Through System. Door Should Be Electrically Controlled Having Fully Automatic Function With Multiple Safety Arrangements. Sealing System Should Be Based On Silicone Seal.4. Should Have At Least 50Mm Thick Insulation Materials On Jacket And In Doors To Ensure Low Thermal Losses. Working Temp. Of The Door Should Be Less Than 45Deg. C. 5. Should Be High Grade Stainless Steel.6. Should Have A Built In Colousr Touch Screen.7. Should Have Audio Visual Alarms In Case Of Undesired Situations. 8. Should Have Programmable Operators Access Level. 9. Should Have At Least 10 Pre Programmed Standard Cycles Plus 5 Or More User Programmable Cycles And Provision Of Chip Card Port For Loading Of New Programs Through Chip Cards.10. Should Have Temperature Adjustable From 25Deg. To 135 Deg. C. 11. Safe Working Pressure Range Should Be Adjustable 12. Should Have Complete Monitoring Of Cycle Operation And Provided With At Least Two Pressuresensors And Two Temp. Sensors ( Pt -100 ) In Addition To Analog For Chamber Pressure, Jacket Pressure And Steam Generator Pressure Indication.13. The Unit Should Be Equipped With Multiple Safety Mechanisms For Emergency Stop Over Pressure Safety Valves For Chamber And Jacket, Over Temp Safety, Steam Traps And Electrical Safety.14. The Unit Should Include Non Fade Built In Thermo-Recorder For Step Progress Values During The Cycle With Time And Date And Alarm Condition If Any.15. Should Have Built In Feature Of Water Saving System For Water Conservation.16. Should Be Supplied Complete With High Quality Stainless Steel Trolleys And Sterilization Baskets: A. External Trolley = 01 Nos.B. Internal Trolley With Steel Roller C. Shelves = 01 Nos. And D. 2 Sets Of Sterilization Baskets. 17. All Accessories & Electric Fitting To Be Included 18. Three Compulsory Visits For Calibration And Check-Up Irrespective Of Complaints In Year.19. The Steam Generator Should Be Also Be Made Of Aisi 316 Ti Steel & The Steam Generator Should Be Equipped With Automatic Cleaning Facility. 20. Integrated Waste Water Cooling, Integrated Water Saving Device. Touch Screen Display, Chip Card Reader And Rs 232 Interface. , Hot Air Oven : Capacity 250 Litre, Temp Range: +5ºc To 250ºc. Control Accuracy: ±0.2ºc, Uniformity: ± 2.0 At 100.0ºc Minimum 3 No. Of Shelves With Height Adjustable In 25Mm Steps, Glass Window In-Built Into The Door For Easy Viewing Of Samples, Automatic Cut Off Of Heater & Blower When Door Opened, Digital Pid Temperature Controller With Timer, Alarms And Auto Tuning, Aero Dynamic Internal Design For Achieving Horizontal Air Circulation, Solid And Plain Bottom Without Electrical, Outer Body Made Of G.I Epoxy Coated Inner Body Made Of Stainless Steel With Clear Bottom Ce Certified. Brand Name And Model Name Must Come In The Display. , Hot Plate : Size 420 X 320 X 130 Mm Ht. ( Total Height With Feet ) Weight 9 Kg, Voltage 230V ( 50Hz ) , Temperature 250°C Maximum Uniformity + / - 2°C.Temperature Rise 6°C Per Minute Temperature Drop 1°C Per Minute, The Hot Plate Should Be Able To Control The Temperature Within + / - 2°C, Temperature Should Be Uniform Throughout The Hot Plate Surface. 6. There Should Be Rims Around The Edges Of The Hot Plate For Safety, Power 2200 W, Approx. 9.6 Amp In 230V, Material Pfa Coated Graphite. , Laminar Air Flow Chamber : Microprocessor Controlled System With Motorised Door. Type Of Airflow: Horizontal Full Password Protected Operation. 70% Of Air Should Be Recirculated To The Cabinet Work Area Through Hepa Filter And The 30% Balance Should Be Exhausted Through Hepa. The Balance Should Be Dynamic To Ensure The 70 / 30 Recirculation / Exhaust Air The Instrument Must Have Hepa Filters On Down Flow As Well As Exhaust With An Efficacy Of 99.99% For Particles Sized Of Calibration Certificates Along With Dop Test Report Shall Have To Be Submitted At The Time Of Supply Of Instrument ) The Dimensions Of The Working Chamber Should Be In The Following Range: Length: 90-120 Cm , Width: 40-60 Cm , Height: 50-80 Cm . The Main Body And Working Chamber Of The Cabinet Should Be Made Of Stainless Steel, Rigid And Rustproof With Removable Trays The Cabinet Should Have An Electrically Operated Sliding Front Sash Made Of Safety ( Uv ) Glass With A Provision For Manual Operation Of The Sliding Front Window. Also, The Sliding Front Sash Should Have True Air And Aerosol Tight Electrical Shahs. Front Door: Clear Transparent Sturdy Material Work Chamber Should Be Fitted With A Fluorescent Lamp For Illumination And Should Have Programmable Uv Light Cycle. The Unit Should Have Microprocessor Control Keys With Large Icons And A Large Graphical Display With Provision For The Permanent Display Of The Following Key Cabinet Conditions. I. Inflow And Down Flow Air Velocity Ii. Exhaust And Recirculated Airflow Volumes Iii. Time And Date Iv. Residual Lifetime Of Filters & Total Time Of Cabinet Operation ( Optional ) Alarm Notification In The Following Situations: I. Low Inflow Velocity Ii. Low Down Flow Air Velocity Iii. Hepa Filter Life Iv. Alarms For Clogged Filters V. Other Malfunction Compatible At A Power Supply Of 220 V, 50Hz Noise Level: < 65 Db Basic Cabinet Should Be Termite And Insect Resistant And Washable Accessories: Manometer, Gas Inlet, Castors The Cabinet Should Be With A Stand With Lockable Castors Brand Name And Model Name Must Come In The Display. , Multimeter With Ion Selective Electrodes For Water Quality Testing : Colour Capacitive Touch Screen With Software Control Facility. Can Store 2000 Sets Of Test Data, Which Can Be Saved And Transferred To Usb Memory Stick And Opened With Excel. Power: Universal Ac Adapter And With Rechargeable Lithium Battery ( Included ) . Concentration Range: ( 0~19990 ) , Can Switch 6 Kind Of Concentration Units: Ug / L, Mg / L, G / L, Mol / L, Mmol / L, Ppm. Concentration Resolution: 4 Significant Digits ( Expressed In Scientific Notation ) Can Be Operated Through 5 Amp Plug And Battery. Accuracy: ±0.1Mv Or 0.03% Temp Range: ( 0? To 100? ) Accuracy: ±0.1? Output Through Usb / Bluetooth Battery Life 1000 Hour. Type: Lithium Battery. Ise- Fluoride, Chloride , Bromide, Ammonia, Brand Name And Model Name Must Come In The Display. , Mechanical Shaker: Compact Bench Top Microcontroller Based Shaker With Temperature Control Range From Ambient +5°C To 60°C , Ergonomicallydesignedwithminimalfootprint Triple-Eccentriccounterbalanceddriveforuniformagitationwith 25Mmshakingorbitmaintenance Freepermanent ( Self ) Lubricatedshieldballbearingsfornoiselessoperationfrpexteriorwithanti-Vibrationmountforsmoothrunning Preciseshaking Speedcontrolwithgentlestart / Stopcycle, Preventingspillagepowerfulpermanentmagnetdcdrivewithdigitalleddisplayofspeed Pulsewidthmodulation ( Pwm ) Basedspeedcontroloptionaltimerfunctionforspeed Autore-Starttosetspeedafterpoweroutage Universalplatformtoaccommodateerlenmeyer, Roundbottom, Volumetricflasks, Testtube Holders&Microplateholders Hasautorestartfunctionafterpowerinterruptionwithnonvolatilememory ( Retainsetparametersafterpowerfailure ) Orbital Shaking With Orbit Diameter Of 25 Mm, Speed 20-450 Rpm With Accuracy Of ± 2 Rpm, Led Display , Universal Platform And Clamps To Hold Flaskscapacity 100Ml-64Nos Or 1000Ml. -16Nos, Tray Dimension : 450 X 450 Mm, Noiseless Operation, Operational Voltage - 220 ± 20V, 50 Hz, Should Meet Ce Standards , Mechanical Soil Auger : Soil Auger Sampler : Made Of Iron : Screw Type, One Meter Long With Handle :Size : 2.5 Cm. Dia , Microprocessor Based Flame Photometer : Alphanumeric Graphics Lcd ( 240X 128 Dots ) Brand Name And Model Name Must Come In The Display Microcontroller Based Na, K, Li, Ca& Ba Auto Ignition Gas Leak Sensor Auto Gas Cut Off. Pass Word Protection. Separate Logging For Guest And Administrator Quadratic Curve Fitting Rtc High Quality Compressor Software Na Minimum Concentration Without Dilution 2 Ppm And 0 -200 Meq / L With 1:100 Dilution Ba Can Be Measured Upto 3000Ppm Without Dilution In Higher Concentration Mode And 500Ppm At Lower Concentration Mode. Caupto 250 Meq / L With 1;100 Dilution Bandwidth 10Nm Curve Fitting Accuracy ±2% F.S Pc Link Software To Send Data To Pc. Gas Cylinder And Regulator Must Be Supplied. Product Must Be Ce Certified And Company Should Bear Iso Certification. Brand Name And Model Name Must Come In The Display. , Microtomy : Section Thickness Range: 0.25 - 60 ?M Trimming Thickness Range: 5 - 500 ?M Resolution: 0.25 For 0.25 - 1 ?M 0.5 For 1 - 5 ?M 1 For 5 - 20 ?M 2 For 20 - 30 ?M 5 For 30 - 60 ?M Resolution: 5 For 5 - 10 ?M 10 For 10 - 100 ?M 20 For 100- 200 ?M 50 For 200 - 500 ?M Knife Carrier Retraction During Return Travel Of The Specimen: 60 ?M Horizontal Feed Range Of The Knife Carrier: Max. 28Mm Vertical Specimen Stoke: Max. 64Mm Specimen Size: 55 X 50 Mm Specimen Orientation: X And Y Axes: Universal 8º Z Axis: Up To 360º , Microwave Digestion System : Large Furnace Cavity Design With Completely Independent Intellectualproperty Rights, 1~6 100Ml Ultra-High Pressure Digestion Tanks Can Be Placed At The Same Time; Industrial Grade 1000W Magnetron. Temperature And Pressure Dual Measurement And Control, Precise Control, Active Prevention Of Over-Temperature And Over-Pressure, Maximum Working Pressure: 6Mpa, Maximum Withstand Temperature: 300°C, Maximum Working Temperature: 250°C High-Precision Anti-Interference Pressure Sensor Adopts Double Explosion- Proof Control Mode To Directly Measure The Actual Reaction Pressure In The Digestion Tank, The Pressure Measurement Range Is 0~10Mpa, And The Pressure Measurement Accuracy Is 0.01Mpa; Insert High-Sensitivity Platinum Resistance Temperature Sensor, Directlymeasure The Actual Reaction Temperature In The Digestion Tank, The Temperature Range Is 0~300°C, And The Temperature Measurement Accuracy Is ±0.1°C; It Can Measure And Control The Pressure And Temperature In Any Reactiontank, And The 7-Inch High-Definition Camera Display Accurately Shows The Chemical Reaction Process; Equipped With Perfluorination Digestion Tank Or Ft Double-Layer Digestion Tank: Ptfe Digestion Tank Is Made Of Ptfe ( Polytetrafluoroethylene ) , And The Sheath Is Made Of High-Strength Explosion-Proof Aerospace Composite. The Fiber Material Is Made By One-Time Die-Casting, High Temperature Resistance, High Pressure And Strong Acid Corrosion Resistance; Easy Disassembly And Assembly, Fast Cooling; Double Venting Protection And Digestion Tank For Venting Holes And Sealed Bowls; Up To 6 Ultra-High Pressure Digestion Tanks Can Be Placed At The Same Time; The Furnace Cavity Is Ventilated With Acid Resistance, Large Air Volume Centrifugal Fan, And The Exhaust Air Volume Is 5M3 / Min; Specially Designed Self-Locking Ground Moving Safety Door To Resist Accidental Explosion And Microwave Leakage. Tank Technical Parameters: The Pressure-Resistant Jacket Material Is A Hydrophobic High-Strength Pressure-Resistant Composite Fiber Material, Which Is Explosion-Proof And Supports Washing And Easy To Clean. The Inner Tank Adopts Imported Modified Polytetrafluoroethylene ( Tfm ) , High-Strength Frame Type Closed Ultra-High Pressure Reaction Tank: The Highest Withstand Temperature =300 °C. Explosion-Proof Membrane Automatic Pressure Relief And Peek Compressionmodule Pressure Relief Safety Design To Ensure The Safe Operation Of The Instrument. The Whole Tank Pressure Monitoring System, The Threshold Value Can Beadjusted. Using High-Strength Engineering Plastics For One Injection Molding, Independent Ultra-High Pressure Digestion Tank Holder. Tank-6Pcs, Power- Ac220v / 50Hz / 10A, Microwave Frequency-2450 ( Mhz ) , Microwave Output Power-1000 ( W ) , Microwave Cavity-45 ( L ) , Protective Spraying- Pfa, Control Heating Method- Pid, Temperature Ramp-1~50? / Min, Cooling Time-=25Min, Microwave Leakage-=0.3Mw / Cm2, Temperature Control Range-0~300?, Temperature Control Accuracy-0.1?, Pressure Control Range-0~10Mpa, Pressure Accuracy-0.01Mpa, Outer Tank Material- Peek, Inner Can Material- Tfm1700, Highest Temperature Resistance-300?, Operating Temperature-250?, Highest Pressure-15Mpa , Microwave Oven : Convection Microwave Oven With Ceramic Enamel Cavity 21L ( 1. Capacity: 0.7 Cu.Ft. / 21 Ltr., 2. Heat Source: Convection 3. Power: Power Consumption ( Microwave ) 4.1200W 5. Power Source: 230V / 50Hz 6. Output Power ( Max ) : 2350W 7. Powerlevel:6 8. Display Type: Led Bar 9. Control Method: Membrane 10. Door Opening Type: Handle 11. Microwave Distribution: Turntable 12. Cavity Interior :Ceramic Enamel ) , Millipore Water Purifier : Parameter Value Or Range Pressure 2 – 6 Bar Flow Rate > 10 L / Min At 2 Bar Feed Water Type Potable Water Temperature 5 – 35 °C Conductivity 10 – 2000 ?S / Cm At 25 °C Ph 4 – 10 Hardness ( As Caco3 ) < 300 Ppm Silica Concentration <30 Ppm Carbon Dioxide Concentration ( Co2 ) < 30 Ppm Langelier Saturation Index ( Lsi ) < 0.3 Fouling Index ( Fi5 ) Or Silt Density Index ( Sdi ) = 7 ( * ) Total Organic Carbon ( Toc ) < 1 Ppm Free Chlorine < 1.5 Ppm Typical Water Quality Measures With A Well-Designed And Maintained Distribution Loop Of 20 Meters: Flow Rate Pressure 5 Lpm / 1.32 Gpm 2.2 Bar / 32 Psi 15 Lpm / 3.96 Gpm 1.9 Bar / 28 Psi20 Lpm / 5.28 Gpm 1.6 Bar / 23 Psi Plumbing Connections Inlet ( Feed Water Connection ) 3 / 4 Bsp Loop Start / Return 1 1 / 2 Sanitary Tc Drains 3 / 8” Lab Water Purification Systems - Type 2 ( Pure ) , Muffle Furnace : Controller: Should Be Microprocessor Based & At Least 8 Segment Programmable Or Equivalent Controller With Necessary Safety Features. Programmable Temperature ( Pid Controller ) Controller With Heating Rate Control From 10?C / Min To 40?C / Min. ( Fast Heating Rate Would Be Preferable ) , Heating Element :Kanthal A1 And Backed By High Temperature Ceramic Insulation , Safety: Over Temperature Protection& Over Load Protection ( Safety Controller ) Should Provided. Door Safety Switch Must Be Provided So That It Disconnects Power Supply To Heating Element When Door Opens. Should Be Equipped With Digital Over Temperature Protection Circuit To Fail Safe In The Event Of A Controller Malfunction , Critical Electronics Component And Heating Elements Protected By A 35A Circuit Breaker., Weight : Less Than 100 Kg , Two Set Of Operation And Maintenance Manual Should Provided. , Ph Meter : Supply Of Bench Top, Digital Ph Meter Along With All Its Accessories And Spares Required Brand Name And Model Name Must Come In The Display. To Operate The Instrument As Per Specification Given Below: The Direct Reading Laboratory Ph Meter ( Digital ) Operable At 230V + / - 10V A.C., 50 Hz Powersupply With Necessary Cable Connections And Other Standard Accessories Required For Smoothoperation. Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2, Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C, Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C, Temperature Compensation : It Should Have Both Automatic And Manual Temperaturecompensation Touch Screen Display , Parameters Likeph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level.Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter. Storage Of Instrument : It Should Be Able To Stored In Temperature Of 5 To 40 °C And Relative Humidity Of 5 To 80% ( Non-Condensing ) Glp Compliance : It Should Be Glp Complied .To Improve The Reproducibility, It Should Allow To Choose From At Least Three Endpoint Criteriaaccording To Our Requirements.The Electrode Holder Should Move In A Perfectly Vertical Way, Making It Easy To Place The Sensor In The Perfect Position I.E. Vertically In The Measurement Beaker. It Should Be Able To Connect Peripherals Via Usb And Rs232, Increasing Its Possibilitiessignificantly. Export Of Measurement Data And Calibration Data Should Be Possible To Usb Stickto Direct Pc Software Whenever Required By Us. It Should Allow Monitoring Of Limits Of Parameter Ph By Giving A Warning Message When The Value Falls Below Or Exceeds The Predefined Limits. It Should Have Facility Not To Delete Of Data And Changing Of Settings In Routine Mode. Hence It Required To Be Pin Protected For Login, Deletion Of Data, System Settings Etc. It Should Have Choice Of Endpoint Formats Like Automatic, Manual And Timed. It Should Have Choice Of Ph Decimal Places Like X.Y, X.Yy & X.Yyy ( Up To One, Two Andthree Decimal Places. ) It Should Have Data Storage Up To 1000 Measurements ( Min. ) It Should Have Ph Sensor Input Through Bnc Connector With Impedance Of More Than 3 X 1012O . It Should Have Temperature Sensor Input. It Should Be Able To Show The Quality Of Last Calibration On Its Screen. , Precision Drier : Capacity, Material And Construction: Cap:3Ltr / H Evaporation Rate. Suitable For Aqueous Feed Solution. Laboratory Scale Model. External Body –Ss316. Drying Chamber And Cyclone In Full Ss 316L Construction. Total Construct Size: 1200 X 1300 X 2000 Mm ( ±10% Dimesional Tolerance ) , Self-Supported On Castor / Wheels ( Compressor Size Is Extra ) . Weight: Max 130 Kg ( ±20% ) ( Compressor Weight Is Extra ) Chamber: Chamber Size: Diameter-280-350Mm, Length- 600-1000 Mm, With Conical Bottom. Feed Pump: Variable Speed Gearless Peristaltic Pump With Dual Teflon Rollers And Precise Speed Control. Feed Pump Should Be Of Repute Make Preferable Watson Marlow / Miclin / Flowtec Or Equivalent. Silicon Tube For Feed. Pump Should Be Controlled Through Plc And Manually As Well. Spray System And Nozzle:Moc For Two-Fluid Spray Nozzle: 316L Variable Aperture Nozzle Of 0.7Mm.Other Sizes Such As 0.5 / 1.0 / 1.2 / 1.5 / 2.0 / 2.5 Mm May Be Available. Auto De-Blocking System For Spray Nozzle Which Will Be Fitted On Nozzle Controlled Through A De-Blocker Timer. An Additional Spray Aperture For Future Use Should Be Included. Nozzle Geometry And Design Must Be Submitted With A Tender Document. Desired Output Particle Size Range 20-45 Micron, Compatible With Ceramic Slurry Also. Controller And Display: Plc Based Operating System With A Multi-Touch Colour, Interface, 9” Hmi With Data Logging, Online Trends, Recipe Functionand Ability To Store Recipes And Recall For Ease Of Use. Plc Of Repute Make Such As Siemens, Delta Or Equivalent Etc. Thesystem Should Have An Audio Visual Alarm For A. Inlet Temperature, Outlet Temperature And Atomization Pressure. Thesystem Should Have Parameter Control And Safety Interlock. Inlet / Input Air Temperature / / Temperature Range: Ambient To Minimum 260 Degrees C, Variable And Selectable Aspirator Airflow:Max. 150 Cum 3 / Hr With Vfd For Motor Control Of Repute Make Such As Delta, Fuji Or Equivalent Air Heater:Electrical Heater With Minimum 6.0Kw Capacity Inlet Filter:Combination Type ( Pre + Hepa ) For Pre-Filtering Environment Air To Keep Most Impurities And Particles Away From The Spray Drying Process, Outer Filter Assembly: Mainly To Protect Aspirators From Fine Particles. It Should Include Spun Bound Polyester Cartridge With Ptfe Coating. Efficiency- 1Micron Down To 99.99%.Compressor: Oil-Free Air Compressor Piston Type With Min. 20L Air Reservoir 1Hp Power Supply: Single-Phase, Compatible With Indian Standard , Quartzdouble Distilled Water Plant: All Quartz, Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easily Mountable For Cleaning And Maintenance With Spiral Heaters, Electrical Requirement: 230-250 Volts 10 / 50Hz, Single Phase, Dist. Water Output Capacity ( Ltr / Hr ) : 2.5 Ltrs / Hr, Total Power Consumed-4.4 Kw, Conductivity ( ?S / Cm ) : <1*10-6, Distillation Units Type-Vertical, Biological Activity-Pyrogen Free, Double Stage Glass ( Quartz ) Distillation Units-Yes, Double Wall Condenser- Quartz, Cooling Water Consumption ( Ltr / Hr ) -2 Ltrs / Min, Boiler-Quartz, Demountable Model And Should Be Connected With Rubber Tumbling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce / Iso Certified.Primary Boiler Provided With O Ring Accessories Distillation Apparatus Power Supply ( Daps ) : The Unit Provides For Automatic Working Of Distillation Unit By Switching Off The Heaters In Case Water Level Falls Below The Heating Coil, There By Safeguarding The Heaters. The Unit Resumes Distillation When Water Level Is Restored. The Unit Also Comes With Buzzer. Apart From The Above Features, Dual Cut Off: The Dual , Quartz Single Distilled Water Plant: All Quartz, Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easily Mountable For Cleaning And Maintenance With Spiral Heaters, Electrical Requirement: 230-250 Volts 10 / 50Hz, Single Phase, Dist. Water Output Capacity ( Ltr / Hr ) : 2.5 Ltrs / Hr, Total Power Consumed-2.2 Kw, Conductivity ( ?S / Cm ) : <1*10-6, Distillation Units Type-Vertical, Biological Activity-Pyrogen Free, Single Stage Glass ( Quartz ) Distillation Units-Yes, Double Wall Condenser- Quartz, Cooling Water Consumption ( Ltr / Hr ) -1 Ltrs / Min, Boiler-Quartz, Demountable Model And Should Be Connected With Rubber Tumbling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce / Iso Certified. Distillation Apparatus Power Supply ( Daps ) : The Unit Provides For Automatic Working Of Distillation Unit By Switching Off The Heaters In Case Water Level Falls Below The Heating Coil, There By Safeguarding The Heaters. The Unit Resumes Distillation When Water Level Is Restored. The Unit Also Comes With Buzzer. Apart From The Above Features, Dual Cut Off: The Dual Cut Off Switches Off The Heater Even When There Is No Cooling Water Supply To The Condenser. , Refrigerator : Frost Free Refrigerator : Auto Defrost Function To Prevent Ice-Build Up Capacity 253 Ltrs : Suitable For Small Families And Bachelors | Freezer Capacity: 69 Ltrs Fresh Food Capacity: 184 Ltrs Digital Inverter Compressor – Enjoy Greater Energy Efficiency, Less Noise And A Long-Lasting Performance. It Automatically Adjusts Its Speed In Response To Cooling Demand Shelf Type: Spill Proof Toughened Glass Shelves With Easy Slide Special Features: Easy Slide Shelf, Door Alarm, Inverter, Temperature Control, Cool Pack, Stabilizer Free Operation ( 100 ~ 300 V ) Key Feature : All Round Cooling For Even Cooling Corner To Corner | Power Cool - Enjoy Rapid Cooling Performance | Moistfresh Zone - Preserve The Freshness And Flavor Of Fruit And Vegetables For Longer | Interior Led Light | Moveable Ice Maker | Tall Bottle Guards | Recess Door Handle | Fresh Room | Deodorizer | R600a Refrigerant , Refrigerator-Temperature Control : The Upright Freezer Type Comes With An Abs Make Interior. Its Outer Body Is A Painted Steel Board, The Door Comes With A Handle And A Safety Lock On It, There Are Casters Provided For Easy Handing, Its Inner Drawers Are Made Of Plastic Control System : Uses A Microprocessor-Based Temperature Controller • The Temperature Control Range Is Adjustable Between -10°C To -20°C • It Has A Digital Temperature Display, Equipped With Audio Such As: High Or Low Temperature Alarm, Chamber Volume 270Ltr, Chamber Dimensions 800X500x500 Outer Dimension 1060X695x792 Input Voltage 230Vac 50Hz , Semi-Automatic Nitrogen Protein Analyzer : Analyzer Should Be Semiautomatic System Consisting Of A Digestion Unit, A Scrubber Unit, And A Distillation Unit. Digestion Unit: Automated With Integrated Programmable Control, Should Have Electrically Heated ( 230 ± 10 Volts, 50 Hz Ac ) Metal Blocks. It Should Be Capable Of Providing A Temperature Range From 100°C - 440°C With ±10°C Repeatability. Should Have Inbuilt Temperature Controller With Digital Display And Led Display Along-With Manual Temperature Adjustment. Heating Time Setting With Steps From 1- 150 Minutes Should Have The Capacity To Accommodate At Least Eight Numbers Of Digestion Tubes Each Of At Least 250Ml Capacity , Should Have Leak Proof Integrated Condensers ( Fumes Carriers ) Made Up Of Glass, Fixed On A Movable Panel Along With Adopter For Outlet To The Scrubber Unit. Proper Digestion Exhausts System. Scrubber Unit Should Be An Oil Free Centrifugal Suction Type, With Manual Vacuum Adjustment Facility. Corrosion And Impact Resistant Provided With Condensate And Acid Fumes Collection Vessels. Should Operate On 230 ± 10 Volts, 50 Hz, Ac Power Supply. Distillation Unit Fully Programmable Distillation Unit Including Sample Dilution, Alkali And Receiver Addition, Distillation And Tube Draining Facility. Validated Procedure / Certification For Tkn Distillation Like Aoac, Epa, Din, Iso Etc, Should Be Made-Up Of Standard Quality Borosilicate Glass. Should Possess A Steam Generator Made-Up Of Borosilicate Glass Along With Heater And Have 3 Step Manual Control Facility I.E. Standby, Water Inlet And Distillation. Should Have Inbuilt Bellows Pump For Accurate Reagent ( Alkali / Acid ) Dispensing. Should Have Ventilation Valve. Should Have Timer For 5 - 15 Minutes With Audio Signal. Steam Inlet Tube Should Be Of Ptfe. Unit Should Have Quick Clamping Device For Digestion Tube With Adaptor. Should Operate On 230 ± 10 Volts, 50 Hz, Ac Power Supply. Complete Unit Shouldprovided With One Set Of Digestion Tubes Along-With The Servicing, Operating And Maintenance Manuals. Can Able To Monitor And Measurement Of Distillate Temperature. Self Adjusting Cooling Water Control Facility Safe Feature For Safe Distillation. Can Be Upgradeable Whenever Required Accessories: 2 Set Of Digestion Tubes, Digestion Tube Stand, Spillage Tray For The Condensers, Tube Removing Device , Soxhlet’S Apparatus : Body Constructed In Ms Epoxy Coated Finish , Featuring Use Of Mantle Type Heaters That Comes With Support Of Energy Regulator, Capability To Handle 6 Tests, Can Handle Flasks Of 250Ml Capacity, Supplied Withsupport Of Clamps As Well As Rubber Tubing, Works On Electric Supply Of 220 / 230 Volts, 50 / 60 Hz Ac, Suitable To Heat Soxhlet Flasks Of 250Ml , Top Loading Balance: Maximum Capacity ( Or ) Range Of The Balance80-90 / 220 Gm Readability 0.01 Mg ( 0.00001 Gm ) / 0.1 Mg ( 0.0001 Gm ) Tarring Range 0 – 220 Gm Display Backlit Graphics Display / Lcd With Touch Screen Operation. Repeatability ( Standard Deviation ) 0.03 Mg ( Small Range ) / 0.10 Mg ( Large Range ) , Linearity ±0.20 Mg / ±0.10 Mg, Eccentric Load 0.30 Mg, Calibration Adjustment With Internal Weights, Fully Automatic Calibration Technology With Temperature Controlled, Data Memory Function For Keeping Weighing Data & Calibration History Data, 10 Sensitivity Drift ±2Ppm / °C ( When Automatic Self Calibration Is Not Used ) Stabilization ( Typical And Fast ) Approx. 4.0 Sec ( 0.1Mg ) / 15 Sec ( 0.01Mg ) , Size Of Weighing Pan ~ 80 - 90 Mm, Shielding Glass Draft Shield With Flexible Configuration Protective Cover For The Terminal, Replaceable Feed Through For Weighing Below The Balance, Power Supply To Be Operable With 230 V Ac, 50 Hz Power Supply. Accessories Power Supply Cable With All Accessories For Operation, Operating & Service Manual 2 Sets ( Of Hard Copies ) With Calibration Certificate Of The Balance. Soft Copy Of Instrument Operating Manual To Be Sent During The Time Of Installation, Interface Standard Bi-Directional Rs-232 Interface, Dust Cover One. , Ups For The Laboratory : 10Kva - 192V-8Kw Online Ups , 16Nos External Battery Module With Iron Rack, Ups / Automatic Bypass Facility, True Double-Conversion Online Ups, Microprocessor Control For Higher Reliability. Pure Sine Wave.Input Power Factor Correction. Wide Input Voltage Range ( 110 V – 300 V ) . Generator Compatible, Selectable Charging Current - Allows Flexibility To Add Any Battery Size, Emergency Power Off , Uv-Visible Spectrophotometer : Double Beam ( 185-1100Nm ) Spectrophotometer With Standalone Colour Lcd Display With Pc Controlling Software -Optical System: Double Beam, Diffraction Grating -Minimum 1800 Lines / Mm, Scan Speed :6000Nm / Min, 8 Position Sample Holder, Photometric Details Range Must Cover From -4 To + 4, Bandwidth Variable ( 0.2Nm -6Nm ) Stray Light < 0.05% T @ 220, 340 ( Must Cover Less Than 370Nm ) , Baseline Flatness Must Cover +- 0.006A, Detector- Photodiode / Single Photodiodes / Dual Silicon Photodiodes, Power 240+- 10%, 50-60 Hz, Light Source- Xenon Flash Lamp, Wavelength Details-, Accuracy- Must Cover 1.0Nm, Measuring Modes- Absorbance, Transmittance ( % ) , Concentration, Operating Modes: Single Wavelength, Multiple Wavelength, Time Scan, Data Presentation- Display Analysis Results And Graphic Data On Screen, Pc Link Software, Port To Data Transfer, Supplier Should Provide Service For Installation, Demonstration, Training For All Operation Procedure, Temperature Range- Operating Conditions Should Cover +10 Degree C To 40 Degree, Analytical Quality Assurance- Instrument Should Have Internal Quality Assurance Tools, Certification- Must Comply Ce Certificate. Accessories: Quartz Cuvettes: 50Mm Length, 10Mm, 20Mm Path Length ( Each 2 Pairs ) , Original Catalogue To Be Enclosed. Dedicated Branded Pc To Be Quoted With The System .Should Have Manufacturer’S Service Centre In West Bengal And Details Location To Be Mentioned In The Quotation.. , Vertical Autoclave : Quality Systems For Medical Devices Built: • Floor Standing Vertical Type Top Loading Autoclave • Outer Dimensions: Width 75-87 Cm; Height 90-110 Cm; Depth 65-80 Cm Software Control:• Fully Microprocessor Based Proportional Integral Differential ( Pid ) Pressure Control• Controller And Software Should Comply With International Standards Such As 21 Cfr Part 11 Or Any Other Equivalent.• Should Have Facility To Store Identification Codes And Password Codes For Access Level Control• Built –In Memory To Store Number Of Cycles Sensors:• Should Have In-Built Platinum Resistance Temperature Detector With A Typical Resistance Of 100 O At 0°C That Complies With International Standards Of Safety Requirements For Electric Equipment For Measurement Control And Laboratory Use, Eg. Iec61010-1, Iec 61010- 2-040 • Option To Connect Additional Temperature Sensors And Pressure Sensors Should Be Available Display:• User Interface Should: • Be Easy To Operate• Have Digital Display Enabling Visualization Of Stage Of The Cycle, Set And Process Temperature, Pressure And Quick Access To Important Information • Preferably Have Graphical Display Of Temperature And Pressure• Have Notification For Replacement Of Filters After Appropriate Number Of Runs Performed. Chamber Volume: Should Be Not Less Than 100 Litres And Preferably Should Be 150-180 Litres In Capacity. Suitable Number Of Basket For Bottle, Vessels Or Agar Media Preparation Should Be Quoted Along With The Instrument.Chamber Material: Should Be Long Lasting, Made Up Of 316Ti Grade Stainless Steel Of Asme / Ul Grade Chamber Pressure: Chamber Should Be Designed To Withstand At Least 2.8Bar / 142°C And Should Meet, European Pressure Equipment Directive ( Ped 97 / 23 / Ec ) .2 | 2 Chamber Heating: Should Be Heated Uniformly By A Heating Plate On The Outer Wall With Heater Of Suitable Wattage For Quick Heating.Chamber Insulation: Chamber Should Be Completely Insulated With Chloride Free Glass Wool. Sterilization Temperature Range: 105°C To 137°C With Accuracy Of ± 0.1 Deg C At 121 Deg C & An Additional Isothermal Temperature Range Of 60°C To 105°C. Should Have Feature Minimizes The Time Liquids Are Exposed To High Temperatures During Sterilization Thereby Protecting Liquid Media, Saving Laboratory Time And Reducing Energy Consumption. Biohazard And Waste Management System: Should Have The Facility To Filter Air Removed From Chamber Before Sterilization That Isuseful For Sterilization Of Biohazard Waste.Safety: • Water Level Monitoring And Maintenance Of Constant Level For Safety Of Heaters. • A Safety Device To Prevent Opening The Door When The Chamber Is Pressurized. • Prevent Starting Of Runs If Doors Are Improperly Locked.• Safety Feature Should Allow Opening Of Doors Only When The Temperature Reaches A Pre-Set Temperature And Pressure Reaches Atmospheric Pressure.Power Requirement: A Suitable Size Of Electrical Switch Gear 3 Phase 440 Volt With Earthing Andrecommended Size Of Current Capacity Mccb Will Be Made Available On Wall At Appropriate Place. Other Connection And Installation Has To Be Done By The Supplier. , Hydrometer , Keen Boxes , Aluminium Box , Brass Sieve , Mortar And Pestle , Different Types Of Augers: , Screw Type , Post Hole Type , Dutch Type , Stirrera. Magnetic B. Electric , Khurpi , Electric Heater , Room Thermometer , Gps Machine , Camera , Lcd Projector
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 28
West Bengal View Result →
47.
Educational and Research Institute #8811347 Technical Bid
Supply Of Equipment-1.01 Ohm’S Laws Apparatus With In Built Power Supply 1.02 Kirchoffs Law Apparatus 1.03 Superposition Theorem Apparatus. 1.04 Thevenin’S And Norton’S Theorem Apparatus 1.05 Maximum Power Transfer Theorem Apparatus 1.06 Connection And Measurement Of Power Consumption Of Various Lamps. 1.07 Experement : Hartley Oscillator 1.08 V-I Characteristics Of Incandescent Lamps And Time Fusing Current Characteristics Of A Fuse. 1.09 Calculation Of Current, Voltage And Power In Series R-L-C Circuit Excited By Single Phase Ac Supply And Calculation Of Power Factor. 1.10 Verifying B-H Curve Of An Electromagnet. 2 Network Theory Lab 2.01 To Observe A.C. Wave Form On C.R.O. And Calculates Average & R.M.S. Values, Frequency, And Observe The Response Of Resistance To Ac 2.02 Experement :- Study Of Lead & Leg Network In Ac Circuits To Observe Response Of Inductor And Capacitor To Ac 2.03 Experement :-Calculation Of Impedance In Ac Circuit To Determine Impedance & Plot The Phasor Diagram Of R-L Series Circuit. 2.04 Experement :-Calculation Of Power & Power Factor In Rc Ac Circuit To Determine The Current And P.F. Of R.C. Series Circuit. 2.05 Experement :-Calculation Of Power & Power Factor In Rlc Ac Circuit To Determine The Current And P.F. In R.L.C. Series Circuit. 2.06 Experement :-Rlc Series Resonance With Inbuilt Sine Wave Oscillator 2.07 Experement :-Rlc Parallel Resonance With Inbuilt Sine Wave Oscillator 2.08 Experement :- Calculation Of Power & Power Factor In Rc Ac Circuit 2.09 Experement :-Rlc Parallel Resonance With Inbuilt Sine Wave Oscillator To Determine The Current. In R.L.C. Parallel Circuit. 2.10 Experement :-Rlc Parallel Resonance With Inbuilt Sine Wave Oscillator To Obtain Resonance In R-L-C Parallel Circuit. 2.11 Experement :- Measurement Of Power In Balanced Load Using Two Watt Meter Method In Three Phase Circuit. To Verify The Line And Phase Values For Star Connected Balanced Load. 2.12 Experiment :- Study Of Voltage & Current Relationship In Three Phase Circuits. 2.13 Superposition Theorem Apparatus. 2.14 Thevenin’S And Norton’S Theorem Trainer 2.15 Maximum Power Transfer Theorem Apparatus With Three Power Supplies. 3 Electronics Lab 3.01 Forward & Reverse Characteristics Of Pn Junction Diode 3.02 Characteristics Of Zener Diode 3.03 Study Of Rectifiers ( Half Wave & Full Wave ) & Filters ( Capacitor & Inductor Filter ) 3.04 Input & Output Characteristics Of Transistor In Ce Mode 3.05 Characteristics Of Fet 3.06 Characteristics Of Ujt 3.07 Load & Line Regulation Characteristics Of Regulator 3.08 Frequency Response Of Single Stage Rc Coupled Amplifier. 3.09 To Study The V-I Characteristics Of Pn Junction Diode. 3.10 Determination Of H Parameter. 3.11 To Verify The Truth Table Of Logic Gates Realize And, Or, Not Gates. 3.12 To Realize And, Or Gates Using Diodes And Resistors. 3.13 To Verify The Boolean Algebra Function Using Digital Ic Gates ( Consensus Theorem ) . 3.14 To Realize The Function F ( A, B, C, D ) = ( C+D ) ( A+B ) ( B+D ) Neither Using Nor Gates. 3.15 Design A Half / Full Adder Circuit Using Logic Gates. 3.16 Design A Half / Full Subtractor Circuit Using Logic Gates. 3.17 Design A Binary To Gray Code Converter. 3.18 Design A Function Using K-Map And Verify Its Performance Using Sop & Pos. 3.19 Design Bcd To Seven Segment Display Using 7447 Ic. 3.20 Experiment :- Study Of 4 Bit & 16 Bit Multiplexer 3.21 To Study 8085 Based Microprocessor System 3.22 To Load Content In One Register And Shift It To Another. 3.23 To Move The Content Of One Memory Location To Another. 3.24 To Develop And Run A Program For Finding Out The Largest / Smallest Number From A Given Set Of Numbers. 3.25 To Develop And Run A Program For Arranging In Ascending / Descending Order Of A Set Of Number 3.26 To Perform Multiplication / Division Of Given Numbers. 3.27 To Perform Floating Point Mathematical Operations ( Addition, Subtraction, Multiplication, And Division ) . 3.28 To Perform Computation Of Square Root Of A Given Number. 4 Instrumentation System Lab / Electronics Measurements 4.01 To Determine Output Characteristic Of A Lvdt And Determine Its Sensitivity. 4.02 Study Characteristics Of Temperature Transducer Like Thermocouple, Thermister And Rtd With Implementation Of Small Project Using Signal Conditioning Circuit. 4.03 Study Characteristics Of Light Transducer Like Photovoltaic Cell, Phototransistor And Photodiode With Implementation Of Small Project Using Signal Conditioning Circuit. 4.04 To Study Input- Output Characteristics Of A Potentiometer And Use Of Two Potentiometers As An Error Detector. 4.05 Adc Converter 4.06 Dac Converter 4.07 Measurement Of Passive Elements R , L And C Using Bridge Networks 4.08 Study Of Transducers And Characterization-Power Electronics Lab- 5.01 Study Of Voltage – Current Characteristics Of Thyristor 5.02 Study Of Full Wave Rectifier Using Scr 5.03 Study Of Parallel Inverter Using Scr. 5.04 Study Of Bridge Rectifier Using Scr 5.05 Study Of Series Inverter Using Scr. 5.06 Study Of Chopper Using Scr 5.07 Study Of Circuit Breaker Using Scr 5.08 Study Of Battery Charger Using Scr 5.09 Speed Control Of Dc Series Motor 6.01 Measurement Of Current And Voltages By Low Range Ammeter And Voltmeter Respectively With Shunt And Multiplier. 6.02 Calibration Of Wattmeter At Various Power Factors By Standard Wattmeter 6.03 Measurement Of Power In Three Phase Circuits Measurement Of Active Power In Three Phase Balanced Load By Single Wattmeter Method. 6.04 Measurement Of Power In Three Phase Circuits Using Two Watt Meters. 6.05 Measurement Of Power In Three Phase Circuits Using Voltmeters & Ammeters. Measurement Of Three-Phase Power With 3 Ammeters And 3 Voltmeters. 6.06 Calibration Of Energy Meter At Various Power Factors By Standard Energy Meter. 6.07 Measurement Of Energy In Single Phase & Three Phase Balanced Load Using Electronic Energy Meter. 6.08 Measurement Of Low Resistance By Kelvins Double Bridge. 6.09 Measurement Of Medium Resistance By Wheatstone Bridge 6.10 Measurement Of Resistance, Voltage, Current, Voltage, Current In A.C & D. C. Circuit By Using Digital Multimeter. 6.11 To Measure Linear Displacement By Lvdt And Plot Characteristics. 6.12 Measurement Of Inductance By Maxwell Bridge 6.13 Measurement Of Capacitance By Schering Bridge 6.14 Measurement Of Inductance By Hay Bridge 7 Digitalcommunication 7.01 Observe Waveforms Of Pulse Amplitude Modulation ( Using Natural Sampling & Flat Top Sampling ) . 7.02 Observe Waveforms Of Pulse Width Modulation 7.03 Observe Waveforms Of Pulse Position Modulation. 7.04 Observe Waveforms Of Pulse Code Modulation And Demodulation. 7.05 Observe Waveforms Of Ask Modulation & Demodulation. 7.06 Observe Waveforms Of Fsk Modulation & Demodulation. 7.07 Observe Waveforms Of Psk Modulation & Demodulation. 7.08 Observe Wave Forms Of Qpsk Modulation & Demodulation. 7.09 Observe Wave Forms Of Qam Modulation & Demodulation. 8 Communication System 8.01 Observe Am The Am Signal On Spectrum Analyzer 8.02 Observe Fm Wave & Calculate Modulation Index. 8.03 Am Radio Receiver. 8.04 Voltage Wave Form Analysis At Various Points In Am Receiver 8.05 Observe Input & Output Waveforms Of Am Detector. 8.05 Observe Input & Output Waveforms Of Am Detector. 8.06 Plot Graph Of Sensitivity Of Receiver. 8.07 Plot Graph Of Selectivity Of Receiver. 8.08 Plot Graph Off Fidelity Of Receiver 8.09 Fault Finding Of Am Radio Receiver. 8.10 Fm Detector Characteristics. 8.11 Measure The Length Of Directors, Reflectors, Dipoles And Spacing Between The Yagi Uda Antenna Andc Compare With The Theoretical Value. 9 Control System Lab 9.01 Transfer Function Of First And Second Order System 9.02 Sensors System Control System Study M Lab Platform. 01 9.03 Ac Position Servo System Study 9.04 Dc Position Servo System Study 9.05 Control Through Magnetic Amplifier 9.06 Measurement Of Passive Elements R , L And C Using Bridge Networks 9.07 Study Of Transducers And Characterization 9.08 Digital Simulation Of Linear Systems 9.09 Stability Analysis Of Linear System Using Matlab Or Equivalent Software 9.10 Study The Effect Of P, Pt, Pid Controllers Using Matlab Or Equivalent Software Or Witl Conventional Methods. 10 Strength Of Material Lab 10.01 Young’S Modulus Apparatus 10.02 Torsion Of Steel Beam Apparatus 10.03 Flexure Testing Machine 100Kn Digital 10.04 Euler’S Load Buckling Testing Machine 11 Surveying Lab 11.01 Optical Square 11.02 To Verify Law Of Polygon Of Forces 11.03 Digital Tachometer 11.04 Digital Planimeter 12 Building Materials Lab 12.01 Vickers Hardness Tester 12.02 Mortar Mixer Automatic / Manual 12.03 Concrete Mixer With Cube Mould 13 Geo-Technical Engineering Lab 13.01 Sand Replacement Method 13.02 Laboratory Permeability Apparatus -Falling Head & Constant Head 13.03 Standard Compaction Test App. 14 Hydraulics Lab 14.01 Channel Section Having Sudden Change In Slope For The Formation Of Hydraulic Jump Or Hydraulic Jump Apparatus ( Tilting Flume Apparatus ) 2.5 Meter 14.02 Pitot Tube Apparatus 14.03 Reynolds Apparatus To Study The Types Of Flow 14.04 Determine The Darcy’S Law Apparatus 14.05 Hydraulic Ram Apparatus 14.06 Apparatus To Determine Orifice And Mouthpiece 14.07 Current Water Meter Apparatus 14.08 Dead Weight Pressure Gauge Tester 14.09 Venturimeter Test Rig 14.10 Orificemeter Test Rig 14.11 Francis Turbine Test Rig 14.12 Kaplan Turbine Test Rig 14.13 Bernoulli’S Apparatus 14.14 Losses In Pipe And Fitting Apparatus 14.15 Closed Circuit Pipe Friction Apparatusfriction Losses In Pipe 14.16 Centrifugal Pump Test Rig 14.17 Reciprocating Pump Test Rig. 14.18 Pelton Wheel Test Rig 15 Transportation Engineering Lab 15.01 Aggregate Impact Tester 15.02 Softening Point Of Bitumen 15.03 Flash & Fire Point Of Bitumen 15.04 Penetration Test On Bitumen 15.05 Bankleman Beam Method 16 Laboratory Test For Highway Material: 16.01 Marshall Stability Test Apparatus 17 Advance Surveying Lab 17.01 Stadia Tachometer 17.02 Gps Survey 18 Environmental Engineering Lab 18.01 Bod Test Analyzer 18.02 Cod Test Analyzer 19 Advance Structure Lab ( Elective-Ii ) 19.01 Three Hinged Arch Apparatus 19.02 Three Bar Pin Jointed Truss 19.03 Betti’S Theorem / Elastic Properties Of Deflected Beam Apparatus 19.04 Maxwell Reciprocal Theorem Apparatus 19.05 Begg’S Deformeter Set Apparatus 19.06 Suspension Load Apparatus 19.07 Cantilever Beam 19.08 Portal Frame Apparatus 19.09 Redundant Frame Joint Apparatus 19.10 Behaviour Of Column & Struts Apparatus 19.11 Deflection Of Truss Apparatus 19.12 Two Hinged Arch Apparatus 19.13 Shear Force, Loading & Bending Moment Apparatus 20 Industrial Fluid Power Lab 20.01 Demonstrator Ofmeter In And Meter Out Circuit. 20.02 Demonstrator Of Design, Prepare & Operate Of Sequencing Circuit. 20.03 Demonstrator Of Hydraulic Circuit For Shaper Machine. 20.04 Demonstrator Of Pneumatic Circuit For Speed Control Of Double Acting Cylinders. 20.05 Demonstrator Of Pneumatic Circuit For Speed Control Of Pneumatic Motor 21 Theory Of Machine Lab 21.01 To Find The Ratio Of Time Of Cutting Stroke To The Time Of Return Stroke For Quick Return Mechanism Of A Shaper Machine 21.02 Sketch & Describe Working Of Bicycle Free Wheel Sprocket Mechanism. 21.03 Determination Of Power Transmitted By Any Belt Drive Using Any One Dynamometer. 21.04 Balancing Of Several Masses Rotating In A Single Plane By Graphical Method. 22 Thermal Engineering Lab 22.01 Study Of Solar Water Heating System. 22.02 Trace The Flue Gas Path And Water-Steam Circuit With The Help Of Boiler Model And Write Are Port. 22.03 Determination Of Change In Velocity Of Steam With Steam Nozzle. 23 Engineering Mechanics Lab 23.01 To Verify Force Transmitted By Members Of Truss 23.02 Find Ma, Vr, Efficiency, Ideal Effort, Effort Lost In Friction For Various Loads Andestablish Law Of Machine And Calculate Maximum Efficiency Of Differential Axle Andwheel 24 Automobile Engineering Lab 24.01 Universal Joint. 24.02 Battery And Function Of Charger. 24.03 Study Of Ignition System
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
48.
Drinking Water Supply and Sanitation #8792696 Technical Bid
Supply And Installation Of Modern Scientific And Electronic Instruments For Operation Of Telengiri Dam Instrumentation Of Dam - 1 Providing, Fixing, Testing & Commissioning Electro Digital Water Level Recorder ( Laser Technology With Sms Facility ) Tag To Server Installed At Dam Safety Office, Bhubaneswar With Following Instruments And Structures For Level And Storage Measurement In Reservoir And Opening Depth / Discharge Measurements From Telengiri Dam, Providing Training To The Field Staff Including Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 2 M.S. Structure: - Providing, Fabricating & Fixing M.S. Structure Of Required Length To Suit The Site Protected From Reservoir At Top Of The Dam, Made Of 50 Mm X 50 Mm X 6 Mm M.S. Angle Frame Fixed At Dam Front And At Every 0.5 Meter Distance, Fitting In Power Fastener, Painting With Three Coats Of Epoxy Anticorrosive Paint Including Providing & Fixing Pvc Pipe Of 6 Diameter As Per Site Condition From Dam Fsl To Required Lowest Level Of Water Etc; All Complete As Directed By The Engineer-In-Charge. 3 M.S. Platform: - Providing, Fabricating & Fixing M.S. Platform Of Size 1.25 Meter X 1.25 Meter, Fixed In Power Fasteners, Painting With Two Coats Of Epoxy Paint, M.S. Chequered Sheet For Base Plate Including Installation Of Frp Cabinet And Laser Unit Box, M.S. Railing From Three Sides Etc; All Complete As Directed By The Engineer-In-Charge. N 4 Electroray Unit:- Providing & Fixing Electroray Unit With Laser Beam Mounted On M.S. Plate, Provision For Adjustment In Both Axis, Foundation Frame Of 40 Mm X 6 Mm Strip Foundation Bolts, Frp Float For Buoyantly Thrust, Powder Coating, Electronic Sensor Holding Mechanism Mounted In Base Plate And Covered With Frp Security Plate And Security Box With Key & Lock Arrangement, Capacity Measurement For Water Head Zero To 100 Meters Etc; All Complete As Directed By The Engineer-In-Charge. 5 Programme Unit:- Supply Of Data Storage Unit Built In Ip 65 Cabinet From Environment Protection With 64 Kbe2 From Data Storage Memory, Transfer Port With Electronic Cartridge [ Dongle ] For Powerless Automatic Data Transmission And / Or Instant Data Transmission [ Like Blue Tooth ] , 6V Lithium-Ion Battery For Life More Than 15 Months, Two Lines Display, Time Stamping At Ten Different Modes, Maxim Rs 485 / 422 Line Drivers With High Esd Protection For Rs 485 / 422 Communications, Microcontroller Internal 13 Bit Khz Watch Crystal, Two Lines Lcd Display On Mains Supply, Wireless Data Transmission Port Etc; All Complete As Directed By The Engineer-In-Charge. 6 Frp Cabinet:- Supply And Installation Of Fiberglass Reinforced Plastic ( Frp ) Cabin Of Size 1.20 Meter X 1.20 Meter X 2.10 Meter, Both Side Finish, One Side Door And Sliding Aluminum Windows, Frp Roof At Top Of Cabin, Installation On M.S. Platform Etc; Complete As Directed By The Engineer-In-Charge. 7 Software :- Supply Of Dl-Meter Software ( Version 2.0 ) & Loading On Computer For Following Analysis: A )      Log-In Operation B )     Administration Menu C )      System Information About Name Of Govt., Organization, Office, Place, Signing Authority Etc. D )     Master Menu Content For Relative Head E )      Measuring Station Configurations About Ms Code, Consumer Code, Name, Jurisdiction, Location, Sample, Interval Etc. F )      View Station Settings G )     Transactions For Data Capture, Head Content Table Etc. H )      Reports For List Of Measuring Station, Authorized Users, Daily / Fortnightly / Monthly Schedule Time Interval History Etc. I )       Charts Numerical And Graphical For Monthly / Yearly Head / Content Consumption Distribution Etc. J )       Help For Operation And Maintenance Of System. 8 Fixing & Commissioning Of Dl-Meter Unit And Programme Unit On Pvc Pipe, Foundation Template, Nut-Bolts And Cabinet In Line & Level Completed Item As Directed By The Engineer-In-Charge. 9 Testing & Training For Dl-Meter To Field Staff And Operator For Handling Troubleshooting, Data Transmission, Software Operation Etc; Complete As Directed By The Engineer-In-Charge. 10 Providing And Fixing Fencing To Recorder Cabin For Extra Protection Including 50 Mm X 50 Mm X 6 Mm M.S. Angle Structure Covered With M.S. Mesh Of Size 2.5 Cm X 2.5 Cm With Two Coats Of Anticorrosive Epoxy Painting Etc; All Complete As Directed By The Engineer-In-Charge. 11 Inverter :- Supplying, Fixing, Testing And Commissioning Inverter For Power Back Up To Recorder, Luminous Brand 12 V 500 W Capacity Operating On Mains On Solar Energy With Auto On / Off Switch Over With M. S. Bracket Luminous Brand Lithium Battery Of Capacity 150 Ah Lpt 12150 Htt With Power Connection, Battery Stand, Brackets, Wooden Planks & Rubber Sheets, Led Candle Light Of 5 Watt Bulb, Cover With Packing, Forwarding, Transportation And Installation At Site With All Electrical Fittings, Cable, Switches, Plugs For Battery & Inverter, Recorder And Light Including Testing & Training To Field Staff Etc; All Complete As Directed By The Engineer-In-Charge. 12 Providing & Fixing V-Notch ( 15 Ltr. / Sec ) Made Of Glass Fibre Improved “Venturi” Plate Conforming To Is: 9108 For Accurate Measurement Of Water Flowing Through Channels Comprising Of Masonry Construction Provided With Pre-Fabricated Glass Fibre Lining On Both Sides, A Side Chamber Provided In One Side Masonry Wall Of The Said V-Notch On The Upstream Side, A Pipe Provided At The Bottom Of The Chamber Connecting The Said Chamber With The Water Flowing Through The Flume, A Float Means Provided In The Said Chamber, Enabling Recording The Rising Or Falling Level Of Water In The Said Chamber Such As A Scale Provided In The Said Chamber, Moulded Engraved Gauge Marking In Lit / Sec And Also In Centimeter Including Moulded And Engraved Discharge Table, Capacity Marking, Flow Direction, Manufacturer Name And M.S Pipe Stiffeners, Hold Fasts, Sand Treatment On The Backside Of Plate Etc; Complete Including Concrete Foundation 2.0 M ( L ) X 0.50 M ( W ) X 0.15M ( D ) With Verticlal Concrete Wall Behind V-Notch Of Thickness 0.10 M And Transition Wall For Up-Stream & Down-Stream For 25 M Length With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 13 Providing & Fixing Polymer Composite Improved Calibration Marks With Contact Moulding Process, Both Side Finish, M.S. Strip Embedded Inside, Engraved And Molded Marking For Bands And Figures Covered With Radium And Covered With Two Coats Of Polyurethane For Surface Protection With Marking Of Reduced Levels, Sill, Fsl, Frl, Mwl Etc; With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 14 Providing & Fixing Polymer Composite Improved Calibration Marks With Contact Moulding Process, Both Side Finish, M.S. Strip Embedded Inside, Engraved And Moulded Marking For Bands And Figures Covered With Radium And Covered With Two Coats Of Polyurethane For Surface Protection With Engraved Marking Of Salient Features, Chainages, Numbers And Instructions In Eye Pleasant Colour Combinations As Per Demand For Given Size And Location Including M.S. Frame And Concrete Work With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge ( For Salient Feature Board / Chainage Board / Instruction Board / Data Board Etc. ) 15 Providing, Fixing, Testing And Commissioning Of Vibrating Wire Type Standard Piezometer Of Following Specification To Measure Ground Water Pressure Along With Required Accessories Including Drilling, Boring, Pipe And All Other Statutory Charges Etc; As Per Requirement With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge But Excluding Periodical Read Out Unit & Stop Watch. Specification: *Standard Range : 5-200Ksc *Over Range : 2 X Rated Pressure *Sensitivity : 0.1 % F.S. *Accuracy + / - 0.5 % F.S> * Temp. Range -20ºc To +70º C *Length X Diameter ( 140 Mm X 20 Mm ) / ( 194 Mm X 25.4 Mm ) / ( 140 Mm X 25.4 Mm ) 16 Supplying Periodical Read Out Unit For Piezometer Complete Set With Required Software, Specification And Commissioning With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. Vibrating Wire Read Out Box Shall Be Portable Unit Designed For The Read Out Of All Vibrating Wire Gages And Transducers And Shall Be Capable Of Displaying The Reading In Digits, Frequency ( Hz ) , Period ( Us ) , Or Microstrain ( Μ£ ) . The Read Out Shall Also Display The Temperature Of The Transduer ( Embedded Thermistor ) With A Resolution Of 0.1°C. All Readings Shall Be Transmitted To A Host Computer And Imported Into Spread Sheet And Database Applications. Suitable For All Vibrating Wire Pp Meter To Take The Data From Sensors Directly In Engineering Units. The Unit Shall Store 750 Data With Date & Time And With Rs 232 / Rj45 Port ( Wi-Fi Optional ) To Down Load The Data In A Pc. The Unit Shall Be Rechargeable Battery Operated . Specifications : * Excitation Range : 5 Volt Square Wave * Measuring Resolution: 0.5 Ms. * Memorry: 64K Eprom * Reading Storage : 750 Data In Engineering Mode 17 Supplying & Fixing Digital Display Portable Isi Marked Stop Watch With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 18 Supplying & Fixing High Resonance Cc Tv Camera System, Gorilla Type, With 8 Ch 4 K Net Work Video Recorder, 8 Channel Ip Camera Input, H.265 / H.264 Dual Video Formats, Support 4 K Resolution Up To 8 Mp Recording, 80 Mbps Incoming / Outgoing Bandwidth, Support 1Sata Hdds Up To 8Tb, 3Usb Ports, Support Multi-Brand Network Cameras, Mobile Software: Android, Ios, Cms Software : Ivms Etc; With Following Accessories With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge 19 Cp Plus 8 Ch Nvr 2Sata 20 Cp Plus 2 Mp Ip Ptz ( Moving Camera ) 21 Cp Plus 3 Mp Ip Motorised Verry Focal ( Fixed Camera ) 22 8 Port Poe Switch 23 Survilance Hdd 4 Tb 24 Point To Point Antena 25 Cat 6 Cable 26 Rj 45 Clips 27 Metal Box At Each Camera & Antena 28 Power Point At Each Camera 29 Pole At Each Camera 30 Display Unit And Installation Charges 31 Providing, Fixing, Testing, Training And Commissioning Total Weather Station Tag To Server With Sms Facility Installed At Dam Safety Office, Bhubaneswar With Gsm Interface Metrological Station, Imd Approved Monitoring Of Hourly Data Of Temperature, Humidity, Wind Velocity And Rain Gauge Of Data Transfer Through Sms For Ten Mobile Numbers, Gsm Recharge By Department And Memory Card And Tag To Code Analyser. Server With Software, Mounting Tripod 3 Meter, Earthling Kit, Usb Weather Link With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. Parameters : In Sms A ) Location, Date, Time B ) Rainfall In Pre-Decided Time And Cumulative Rain Fall C ) Temperature Minimum And Maximum In A Day D ) Relative Humidity Minimum And Maximum In A Day E ) Wind Speed Minimum And Maximum In A Day F ) Wind Direction At Pre-Decided Time 32 Providing & Fixing Joint Meter Of Following Specification With All Required Accessories Including Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. A ) Range: 0 - 50 Mm. B ) Accuracy : + / - 0.5 % Fs. C ) Resolution: 0.05 Mm. D ) Emp Limit: 10 To 70 Deg C. E ) Thermister: Ysi-44005 Or Equivalent. Material: Stainless Steel F ) Materials: Stainless Steel ( To Be Installed Between Block No. 2 & 3; 4 Nos. At Each Block Joint To Monitor The Joint Opening ) 33 Providing & Fixing Ph Meter ( Portable ) 3 1 / 2 Digit Lcd Display In Abs Plastic Body With Touch Switches And Combination Ph Electrode Of Following Salient Features With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. A ) Measurers Ph, Mv And Temperature 5 Point Calibration. B ) 16 X 2 Line Alphanumeric Lcd With Backlit. C ) Auto Buffer Recognition Facility. D ) Storage Up To 1000 Samples. E ) Attachment For Centronics Dot Matrix Printer 34 Supply, Installation & Monitoring Of Seismograph Of Following Specification & Parameters From Sl. No. 10.1 To 10.9 Below With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 35 * Performance Tested By University Of Technology Sydney, University Of Melbourne, Ce Certified. * Records Triaxial Data From Integrated Seismometer Continuously To Sd Card Storage. * Fault Detection - Sd Card Full / Error, Power, Temperature * Real-Time Alarm Output To Relay Circuit During Earthquake * Internal Battery Available ( Optional ) . * Designed For Minimum 10 Years Operation. Kelunji Prism Used In Structural Monitoring Have Operated For Over 20 Years, Producing An Aggregate Mtbf Of Greater Than 5 Years 36 Recorder: * Type : 32-Bit Adc * Data Channels : Three, Synchronously Sampled * Full-Scale Signal ( Standard ) 40 Vpp ( Voltas Peak-To-Peak ) * Sensitivity ( Standard ) 419430.4 Counts Per Volt * Preamplifier Gains Available ( User Selectable ) X1, X2, X4, X8, X16, X32, X64, X128, X256. * Frequency Reasonse Dc To 2000 Hz Sampling Rates Available ( Samples Per Second ) 40, 100, 200, 250, 400, 500, 800, 1000, 1600, 2000 37 Sensor: * Type : Velocity * Data Channels : Triaxial ( East-West, North-South, Up-Down ) . * Sensitivity : 868 V / M / S. * Noise Performance Below Nlnm Between 2 And 9 Second Period, Freqency Response 30 Second Period To 80 Hz. 38 Timing: * Reference Time Stamp With Every Pps ( Pulse Per Second ) From Gps Receiver Accuracy: Rms 30 Nano Seconds. 39 Recording: *File Recording Options: Continuous ( Always On ) * Trigger / Alarm: Algorithms Sta / Lta ( Any / All Channels ) , Level ( Any / All Channels ) , System ( Voltage, Memory, Temperature ) . * Storage Memory Type : Sd Card ( Sdhc Or Micro Sd Using Adaptor. Included Storage 32 Gb ) . * Continuous Triaxial Recording Capacity @ 100 Sps Over 1 Year Of Data Stored In A Ring Buffer ( Oldest Data Over Written When Full ) . * File System Format: Fat32, Readable By Windows, Mac & Linux Operating Systems * Data Format: Mini Seed ( With Companion Text Files Containing Station Data ) 40 Power: * Dc Charger Voltage Input Range 10-36 Vdc. * Consumption ( When Recording Continuous Data ) 1.1W * Runtime On Internal 12 V Battery 12 + Hours 41 Physical: * Housing Cnc Milled From Solid Alumimum, Hard Anodized. * Dust And Water Ingression Protection: Ip 67. * Operating Temperature Range ( Up To 100% R / H ) - 20 Deg. C To + 70 Deg. C * Size ( Excluding Connectors ) Ø 135Mm, 225Mm High * Weight ( Standard, With Internal Battery ) 3.1 Kg. 42 User Interface: * Configuraton Interface In-Built Lcd With 4-Line Text Display And 4- Button Input * Data Telemetry Ip Streaming Over Optional Ethernet Adaptor Or 3G Cellular Modem * Remote Set Up And Communications Via Live Stream Application Or Eqserver Web Interface 43 Connectors & Cables: * Power 2 Pin Circular Push / Pull Lock * On-Off Switch : External Push Button * Power Cable 2 M Length With Bare Wire Ends
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
49.
Educational and Research Institute #8789480 Technical Bid
Procurement Of Chemical Items At Rims , Ranchi-1 Rapid Kits 2 Australia Antigen Hbsag Rapid Car - 1 Kit 3 Chikungunya Rapid Card - 1 Kit 4 Combistix 4Parameter - 1 Kit 5 Dengu Kit Igg / Igm Rapid Card - 1 Kit 6 Diastrix 1 Parameter - 1 Kit 7 H.C.V. Rapid Card - 1 Kit 8 H.I.V. Rapid Card - 1 Kit 9 Malaria Antigen Rapid Card ( Pv, Pf ) - 1 Kit 10 Malaria Antibody Rapid Card ( Pv, Pf ) - 1 Kit 11 Pregnancy Rapid Card - 1 Kit 12 Toxo Kit Rapid Card - 1 Kit 13 Troponine I Rapid Card - 1 Kit 14 Syphils Card - 1 Kit 15 Uristix 2 Parameter - 1 Kit 16 Elisa Kits 17 Active Vitamin B12 - 1 Test 18 Total Vitamin B12 - 1 Test 19 T3 Elisa Kit - 1 Test 20 T4 Elisa Kit - 1 Test 21 Tsh Elisa Kit - 1 Test 22 Lh Elisa Kit - 1 Test 23 Fsh Elisa Kit - 1 Test 24 Prolactin Elisa Kit - 1 Test 25 Testosterone Elisa Kit - 1 Test 26 Prostrate Specified Antigen Psa Elisa Kit - 1 Test 27 Dengu Elisa Kit - 1 Test 28 Chikungunya Elisa Kit - 1 Test 29 H.I.V. Elisa Kit ( 4Th Generation ) - 1 Test 30 H.C.V. Elisa Kit ( 4Th Generation ) - 1 Test 31 Hbsag Elisa Kit ( 4Th Generation ) - 1 Test 32 Biochemistry Kits 33 Acid Phosphate - 100Ml 34 Ace With Factor ( Angiotensin Converting Enzyme ) 35 Ada With Factor ( Adenosine Daeminase ) 36 Albumin Kit - 1 X 150 Ml 37 Alpha Hbdh - 1 X 10 Ml 38 Alkalin Phosphate Kit - 1 X 15 Ml 39 Alt ( Sgpt ) - 1 X 150 Ml 40 Ammonia - 1 X 5 Ml 41 Amylase Kit - 1 X30 Ml 42 Anti Ccp With 2 Cal - 1 Ml 43 Ast ( Sgot ) Kit - 100 Ml 44 Bilirubin Kit - 250 Ml 45 Blood Urea - 150 Ml 46 Calcium Kit - 1 X 150 Ml 47 Carbondioxide - 1 Ml 48 Chloride Reagent - 10 Ml 49 Cholestrol Kit - 150 Ml 50 Cholinesterase - 24 Ml 51 Ck-Mb Kit - 75 Ml 52 Copper - Ml - 10 Ml 53 Cpk Kit - 75 Ml 54 Creatinine Kinase ( Ck ) Kit - 75 Ml 55 Creatinine Kit - 250 Ml 56 Cystatin-C - 1 Ml 57 Sgpt - 150 Ml 58 Gulcose Kit - 250 Ml 59 Glycocylated Hemoglobin Kit - 1 Test 60 Hdl Cholestrol Kit - 100 Ml 61 Hdl Cholestrol - Direct - 100 Ml 62 Homocysteine - 100 Ml 63 Iran Tibc - 100 Ml 64 Iron Binding Kit - 100 Ml 65 Laboline Kit - 100 Ml 66 Lipoporotin ( A ) One Kit - 100 Ml 67 Ldh Kit - 100 Ml 68 Micro Albumin - 100 Ml 69 Na+&K+Standard Solution - 100 Ml 70 Quality Control For Clinical Chemistry - 100 Ml 71 Phosphorus Kit - 1 Kit 72 Serum Copper Kit - 1 Kit 73 Total Iron Kit - 150 Ml 74 Total Protein Kit - 150 Ml 75 Triglyceride Kit - 150 Ml 76 Urea Kit - 150 Ml 77 Uric Acid Kit - 150 Ml 78 Serological Kits 79 22% Bovine Albumin - 1 Ml 80 A.S.O. Kit - 100 Kit 81 Anti A1 Lectin - 10 Ml 82 Anti Ab - 10 Ml 83 Anti-D - 10 Ml 84 Anti D Igg / Igm - 10 Ml 85 Anti H Lectin - 10 Ml 86 Anti Human Globin - 10 Ml 87 Anti -A Serum - 10 Ml 88 Anti-Ab Serum - 10 Ml 89 Anti-B - 10 Ml 90 Antigen R.P.R.Kit - 100 Kit 91 Aptt Reagent - 5 Ml 92 Blood Grouping Reagents - 10 Ml 93 C-Reacting Protein ( Crp ) - 100 Kit 94 P.P.D.10Tu - 10 Ml 95 Prothrombin Time Kit - 20 Ml 96 R.A.Test Latex - 100 Test 97 Widal ( Slide Method ) - 100 Test 98 Antibiotic Disc / High Media 99 Amikacin ( Antibiotic Disc ) - 5 X 250 Disc 100 Amoxycillin ( Antibiotic Disc ) - 5 X 250 Disc 101 Ampicillin ( Antibiotic Disc ) - 5 X 250 Disc 102 Azithromycin ( Antibiotic Disc ) - 5 X 250 Disc 103 Bacitaracin Disc - 5 X 250 Disc 104 Carbenicillin ( Antibiotic Disc ) - 5 X 250 Disc 105 Cefadroxil ( Antibiotic Disc ) - 5 X 250 Disc 106 Cefazoloin ( Antibiotic Disc ) - 5 X 250 Disc 107 Cefepime ( Antibiotic Disc ) - 5 X 250 Disc 108 Cefotaxime ( Antibiotic Disc ) - 5 X 250 Disc 109 Cefprozil ( Antibiotic Disc ) - 5 X 250 Disc 110 Ceftazidim ( Antibiotic Disc ) - 5 X 250 Disc 111 Cephalexin ( Antibiotic Disc ) - 5 X 250 Disc 112 Cepodoxime ( Antibiotic Disc ) - 5 X 250 Disc 113 Cholramphenicol ( Antibiotic Disc ) - 5 X 250 Disc 114 Ciprofloxacin ( Antibiotic Disc ) - 5 X 250 Disc 115 Clarithromycin ( Antibiotic Disc ) - 5 X 250 Disc 116 Cloxacillin ( Antibiotic Disc ) - 5 X 250 Disc 117 Co-Trimoxagole ( Antibiotic Disc ) - 5 X 250 Disc 118 Dca Media - 5 X 250 Disc 119 Doxycyclin ( Antibiotic Disc ) - 5 X 250 Disc 120 Erythromycin ( Antibiotic Disc ) - 5 X 250 Disc 121 Gatifloxacin ( Antibiotic Disc ) - 5 X 250 Disc 122 Gentamicin ( Antibiotic Disc ) - 5 X 250 Disc 123 Imipenum ( Antibiotic Disc ) - 5 X 250 Disc 124 Levofloxacin ( Antibiotic Disc ) - 5 X 250 Disc 125 Lomefloxcin ( Antibiotic Disc ) - 5 X 250 Disc 126 Msa Media ( Mannitol Salt Agar ) 127 Nalidixic Acid ( Antibiotic Disc ) - 5 X 250 Disc 128 Netilmycin ( Antibiotic Disc ) - 5 X 250 Disc 129 Nitrofurantoin ( Antibiotic Disc ) - 5 X 250 Disc 130 Norfloxacin ( Antibiotic Disc ) - 5 X 250 Disc 131 Ofloxacin ( Antibiotic Disc ) - 5 X 250 Disc 132 Optochin Disc - 5 X 250 Disc 133 Piperacillian+Tazobactum ( Antibiotic Disc ) - 5 X 250 Disc 134 R.C.M. Media 135 Sim Media 136 Sultax ( Cefoaximen+ Sulbactam ( Antibiotic Disc ) - 5 X 250 Disc 137 T.S.I Media - 5 X 250 Disc 138 Tcbs Media - 5 X 250 Disc 139 Tetracycline ( Antibiotic Disc ) - 5 X 250 Disc 140 Xtum ( Ceftriaxone +Sulbactam ( Antibiotic Disc ) - 5 X 250 Disc 141 Glass & Disposable Item 142 Auto Pipett All Size Varible Volume - 1 Pc 143 Auto Pipette Fixed All Size Volume - 1 Pc 144 Beaker 1000Ml - 1 Pc 145 Beaker 100Ml - 1 Pc 146 Beaker 250Ml - 1 Pc 147 Beaker 500Ml - 1 Pc 148 Beaker 50Ml - 1 Pc 149 Blood Cell Counting Chamber - 1 Pc 150 Blood Collection Bags - Single - 1 Pc 151 Blood Collection Bags - Paediatric - 1 Pc 152 Blood Collection Bags - Double - 1 Pc 153 Blood Collection Bags - Triple ( Plain ) - 1 Pc 154 Blood Collection Bags - Triple Sagm - 1 Pc 155 Blood Culture Bottle ( Plain Vials ) - 1 Pc 156 Blue Tips - 1000 Pcs 157 Bone Marrow Aspiration Needle No.14, 16 158 Capillary Tube 100 Pcs 159 Centrifuge Tube 10Ml - 100 Pcs 160 Centrifuge Tube 15Ml - 100 Pcs 161 Concavity Slide ( One Cavity ) - 100 Pcs 162 Concavity Slide ( Two Cavity ) - 100 Pcs 163 Conical Flask 1000Ml - 1 Pc 164 Conical Flask 100Ml - 1 Pc 165 Conical Flask 250Ml - 1 Pc 166 Conical Flask 500Ml - 1 Pc 167 Conical Flask 50Ml - 1 Pc 168 Swab Stick - 100 Pcs 169 Disposable Plastics Syringe 3Ml - 100 Pcs 170 Drop Bottle 171 Droper 172 E.S.R Tube - 1 Pc 173 E.S.R Tube 6 Stand - 1 Pc 174 Edta Vial - 100 Pcs 175 Flouride Vial - 100 Pcs 176 Glass Cover Slip 18X18mm - ( Box Of 20 Pcs ) 177 Glass Cover Slip 22X22mm - ( Box Of 20 Pcs ) 178 Glass Cover Slip 22X40mm - ( Box Of 20 Pcs ) 179 Glass Cover Slip 22X60mm - ( Box Of 20 Pcs ) 180 Glass Slide - 50 Pcs 181 Graduated Pipettes Of Different Capacity 0.1Ml - 1 Pc 182 Graduated Pipettes Of Capacity 0.2Ml - 1 Pc 183 Graduated Pipettes Of Capacity 0.5Ml - 1 Pc 184 Graduated Pipettes Of Capacity 10Ml - 1 Pc 185 Graduated Pipettes Of Capacity 1Ml - 1 Pc 186 Graduated Pipettes Of Capacity 2Ml - 1 Pc 187 Graduated Pipettes Of Capacity 5Ml - 1 Pc 188 Haemocyto Meter - 1 Set 189 Hardness Testing Kit ( Water Analysis ) 190 Hemoglobin Meter - 1 Set 191 Hemoglobin Tube -1 Pc 192 Urine Culture Port - 1 Pc 193 Magnifying Glass 3 194 Margring Jars With Cover 195 Measuring Cylinder 100Ml 196 Measuring Cylinder 250Ml 197 Neubauer Counting Chamber 198 Pasteur Pipettes With Rubber Bulbs 199 Pastour Pipettes - 1 Pc 200 Petri Disc 4 - 1 Pc 201 Pipette Blb - 1 Pc 202 Plain Vial Glass - 100 Pcs 203 Plain Vial Plastic - 100 Pcs 204 R.B.C Pipette - 1 Pc 205 Reagent Bottle 100Ml ( Silicate With Driper Cap 100Pc ) 206 Round Bottom Flask 207 Rubber Tubing 5 / 8 ( 1Mtr ) - 1 Mtr 208 Rurified Mercury 209 Silver Allow 210 Spirit Lamp - 1 Pc 211 Swab Stick 212 Test Tube 12X100 ( 100 Pcs ) 213 Test Tube 12X75 ( 100 Pcs ) 214 Test Tube 15X150 ( 100 Pcs ) 215 Test Tube Brush - 1 Pc 216 Test Tube Holderv - 1 Pc 217 Test Tube Khan Tube 12X75 ( 100 Pcs ) 218 Test Tube Rack 12 Tube 219 Test Tube Rack 24 Tube 220 Test Tube Rack 36Tube 221 Time Pack Reagent For Adia Cell Counter 222 Tissue Paper Roll - 1 Pc 223 Vaccutainer Neddle - 1 Pc 224 Urinometer - 1 Pc 225 Vaccutainer Glass / Edta ( 100 Pcs ) 226 Vaccutainer Heparin ( 100 Pcs ) 227 Vaccutainer Oxofluride ( 100 Pcs ) 228 Vaccutainer / Glass / Plain ( 100 Pcs ) 229 W.B.C Pipette - 1 Pc 230 Wash Bottle 500Ml - 1 Pc 231 Washing Brush 12 - 1 Pc 232 Washing Brush 6 - 1 Pc 233 Water Filter Papers 11Cm - 1 Pc 234 Wintrobes Tube 235 X-Ray Developer 236 X-Ray Fixer 237 Yellow Tips - 100 Pcs 238 Absolute Alcohol - 500 Ml 239 Acetic Acid Glacial - 500 Ml 240 Acetic Acid Glacial - 500 Ml 241 Acetone - 500 Ml 242 Acid Orthophaphoric - 500 Ml 243 Acrylic Cold Curve Liquid - 500 Ml 244 Acrylic Cold Curve Powder - 500 Ml 245 Activated Charcoal - 500 Ml 246 Adrennalin Hydrochloride - 500 Ml 247 Agar Powder - 500 Ml 248 Alberts Stain-A - 500 Ml 249 Alberts Stain-B - 500 Ml 250 Alcian Blue - 500 Ml 251 Alcohol Ethyl - 500 Ml 252 Alkian Blue - 500 Ml 253 Alpha Napthyl Butyrate - 500 Gm 254 Aluminium Ammonium Sulphate - 500 Gm 255 Ammonium Citrate - 500 Gm 256 Ammonium Oxalate - 500 Gm 257 Ammonium Solution - 500 Gm 258 Ammonium Sulphate - 500 Gm 259 Amulgeum Pluger - 500 Gm 260 Aqua Winthapip - 500 Gm 261 Atropine - 500 Gm 262 Atropine Sulpher - 500 Gm 263 Barbitone - 500 Gm 264 Barium Carbonate - 500 Gm 265 Barium Chloride - 500 Gm 266 Basic Fuchsin - 500 Gm 267 Benedicts Solution - 500 Gm 268 Benzidine Powder - 500 Gm 269 Betaxolo 25% & 85% - 500 Gm 270 Bismark Brown Stain - 500 Gm 271 Boric Acid - 500 Gm 272 Benzoic Acid - 500 Gm 273 Baramathymol Blue - 500 Gm 274 Brillant Crysyl Blue - 500 Gm 275 Bromin Sample - 500 Gm 276 Bromo Cresol Green - 500 Gm 277 Bromo Phnol Blue - 500 Gm 278 Buffered Formal Acetone - 500 Gm 279 Calamine Powder - 500 Gm 280 Calcium Chloride - 500 Gm 281 Calcium Oxide - 500 Gm 282 Calcium Sulphate - 500 Gm 283 Carbol Fuschin - 500 Gm 284 Carbolic Acid - 500 Ml 285 Caustic Soda - 500 Gm 286 Cceto Orcein Powder - 500 Gm 287 Cedar Wood Oil - 100 Ml 288 Chloralose - 100 Gm 289 Chlorophenol Red - 100 Gm 290 Chloroform - 100 Gm 291 Cidex ( Endomax ) - 5 Ltr. 292 Citric Acid - 500 Ml 293 Copper Sulphate - 500 Gm 294 Creatinine Zinc Chloride - 500 Gm 295 Cresyl Blue Powder - 500 Gm 296 Cresyl Blue Brilliant - 500 Gm 297 Crystallin Phenol Powder - 500 Gm 298 Crystalline Phenol - 500 Gm 299 Cylindrical Glass Tubes For Col Chromatography - 1 Pc 300 Deionized Water - 5 Ltrs. 301 G.V.Lotion - 125Ml 302 Gymsalotion - 100 Ml 303 Disinfectant Containing Electrolysed Water With Neutral Ph , Hypochlorous Acid, Sodium Hypochlorite - 5 Ltrs. 304 Distillation Appactub 305 Distilled Water - 5 Ltrs. 306 Dpx - 200 Ml 307 E.D.T.A Powder - 100 Gm 308 E.S.R Fluid 3.8% - 500 Ml 309 Ethyl Acetate - 500 Ml 310 Fast Gernet Bgbc Salt - 311 Filter Paper 11Cm - 100 Pcs 312 Flouride Powder - 500 Gm 313 For Pas - 500 Gm 314 Formaldehyde Solution 37-40% - 5 Ltrs. 315 Formaline Tablet - 100 Pcs 316 G.V.Powder - 100 Gm 317 Giemsa Powder - 100 Gm 318 Giemsa Stain - 125 Ml 319 Glacial Acetic Acid - 500 Ml 320 Glucose Powder - 100 Gm 321 Gluteraldehyde Solution - 5 Ltrs. 322 Glycolic Acid - 100 Ml 323 Glycerin Ip - 500 Ml 324 Gram Stain - 500 Ml 325 Grams Iodine - 500 Gm 326 I.P.A - 2.5 Ltr. 327 Iodine - 100 Ml 328 Isopropyl Alcohol - 2.5 Ltr. 329 Leishman Stain ( 500Ml ) 330 Leishman Powder ( 500Grm ) 331 Liquid Paraffin ( Heavy ) Ip - 500Ml 332 Liquid Paraffin ( Light ) Ip - 500Ml 333 Lysol - 5 Ltrs. 334 Methanol - 2.5 Ltrs. 335 Methylene Blue - 125Ml 336 Methylene Chloride - 125Ml 337 Methylene Violet - 125Ml 338 N / 10 Hcl - 500 Ml 339 Nacl2 - 500 Ml 340 Nitric Acid - 500Ml 341 Ophyde ( Endomax Opa ) - 5 Ltr. 342 Paraffin Liquid - 500 Ml 343 Paraffin Wax - 1 Kgs 344 Wax Granules - 2Kgs 345 Isopropyl Rubbing Alcohol Usp - 2.5 Ltr. 346 Peptone - 100 Gm 347 Pot Chloride - 100 Gm 348 Potassium Thioynate - 100 Gm 349 Potassium Aluminium Sulphate - 100 Gm 350 Powder Sodium Desoxycholate - 100 Gm 351 Powder Sucrose - 100 Gm 352 Powder Sulpher - 100 Gm 353 Psa Stain - 100 Gm 354 R.B.C Fluid - 100 Gm 355 Salicylic Acid - 100 Gm 356 Wax ( Pathology +Physiotherapy ) - 1 Kg. 357 White Petroleum Jelly - 800 Ml 358 Xylene - 500 Ml 359 Zinc Oxide - 500 Gm 360 Zinc Powder - 500 Gm 361 Au 480 Machine Kit 362 Albumin Bcg - 1 Kit 363 Billirubin-D - 1 Kit 364 Billirubin-Total - 1 Kit 365 Calcium Arsennazo111 - 1 Kit 366 Cholesterol Hico - 1 Kit 367 Createnine - 1 Kit 368 Creatinine Enzymatic - 1 Kit 369 Glucose Hk - 1 Kit 370 Hba1c - 1 Kit 371 Hdl-Cholesterol - 1 Kit 372 Phosphorus - 1 Kit 373 Total Protien - 1 Kit 374 Triglycerides - 1 Kit 375 Uibc - 1 Kit 376 Urea - 1 Kit 377 Uric Acid - 1 Kit 378 Acp - 1 Kit 379 Alp - 1 Kit 380 Altl / Sgpt - 1 Kit 381 Amylase - 1 Kit 382 Ferritin - 1 Kit 383 Ast / Sgot - 1 Kit 384 Antitrypsin - 1 Kit 385 Acid Glycoprotein - 1 Kit 386 Anti Streptosylin - 1 Kit 387 Apo-A - 1 Kit 388 Apo-B - 1 Kit 389 Beta-2 Macroglobulin - 1 Kit 390 C3 - 1 Kit 391 C4 - 1 Kit 392 Ceruloplasmin - 1 Kit 393 Crp-Latex - 1 Kit 394 Crp - 1 Kit 395 D-Dimer - 1 Kit 396 Hbdh - 1 Kit 397 Haptoglobin - 1 Kit 398 Iga - 1 Kit 399 Igg - 1 Kit 400 Igm - 1 Kit 401 Lpa - 1 Kit 402 Micro Albumin- Csf / Urine - 1 Kit 403 Myoglobin - 1 Kit 404 Pre-Albumin - 1 Kit 405 Rf - 1 Kit 406 Total Protien - Csf / Urine - 1 Kit 407 Transferrin - 1 Kit 408 Carbamazepine - 1 Kit 409 Digoxin - 1 Kit 410 Digitoxin - 1 Kit 411 Gentamicin - 1 Kit 412 Paracetamol - 1 Kit 413 Phenobarbital - 1 Kit 414 Phenytoin - 1 Kit 415 Theophylline - 1 Kit 416 Valproic Acid - 1 Kit 417 Amphetamines - 1 Kit 418 Barbiturates - 1 Kit 419 Benzodiazepines - 1 Kit 420 Cocaine - 1 Kit 421 Thc - 1 Kit 422 Wash Concentrate - 1 Kit 423 No Foam Reagent - 1 Kit 424 Hdl - Cholesterol Calibrator - 1 Kit 425 Ldl - Cholesterol Calibrator - 1 Kit 426 Bicarbonate Calibrator - 1 Kit 427 Hdl - Cholesterol Calibrator - 1 Kit 428 Calibrator Ldl ( Us ) - 1 Kit 429 Urine Calibrator - 1 Kit 430 Crp Latex Normal Calibrator - 1 Kit 431 Crp Latex High Sensitative Calibrator - 1 Kit 432 Rf Latex Calibrator - 1 Kit 433 Negative Calibrator Dau - 1 Kit 434 Digitoxin ( Tdm Calibrator ) - 1 Kit 435 Multi Calibrator Antibiotic Tdm - 1 Kit 436 Ck-Mb Calibrator - 1 Kit 437 Mc Cal A ( Mastercurve Calibrator A ) - 1 Kit 438 Apo Calibrator - 1 Kit 439 Serum Protein Caibrator - 1 Kit 440 Apo Cal 5 Point - 1 Kit 441 Micro Albumin Calibrator - 1 Kit 442 Myoglobin Calibrator - 1 Kit 443 Pre-Albumin Calibrator - 1 Kit 444 Hba1c Calibrator - 1 Kit 445 D-Dimer Calibrator - 1 Kit 446 System Calibrator - 1 Kit 447 Wash Solution 5Lt - 1 Kit 448 Cleaning Solution - 1 Kit 449 Au Consumables Kit - 1 Kit 450 Haematoxyllin Powder Stain - 1 Kit 451 Eosin - 1 Kit 452 Potassium Aluminium Sulphate - 500 Gm 453 Hc1 Conc. - 500 Gm 454 Thymol - 1 Kit 455 Light Green - 25 Gm 456 Novolinle Polymer - 1 Kit 457 Poly-L-Lysine Solution - 1 Kit 458 Tris Buffer Gr - 1 Pc. 459 Cytogenetics 460 Fetal Bovine Serum, Gold 500Ml 461 Rpmi 1640, 100Ml 462 Colcimed ( Demecolcine ) , 5Mg 463 Potassium Chloride, 500Gm 464 Trypsin , 25Gm 465 Giemsa Stain , 1Gm 466 Saline Sodium Citrate Buffer ( Ssc 20X Buffer ) , 500Ml 467 Pepsin , 1Gm 468 4, 6-Diamidino-2-Phenylindole Dihydrochloride ( Dapi ) , 10Mg 469 Methanol - 250Ml 470 Glacial Acetic Acid - 500Ml 471 Phosphate Buffer Saline - 500Ml 472 Vacutainer Holder 473 Vacutainer Needle 474 B. Beg Single 475 B. Beg Double 476 B. Beg Triple 477 B. Beg Quadruple 478 B. Beg Penta 479 Tube Leveler 480 Tube With Transparent Label 481 Variable Pipette: Micropipette, Adjustable Volume, Fully Autoclavable N• Spring Loaded Tip Cone For Connecting Tips Very Tightly N• Adjustment Opening For Adjusting Pipettes To A Specific Liquid And Volume. N• Control Button With Very Low Operating Force, Color Indication For Pipette Volume. N• Tip Ejector With Very Low Operating Force, Positioned For Perfect Ergonomics. N• Volume Display: 4 Digits With Magnifier. N• To Provide Thermal, Mechanical And Chemical Stability Piston Should Manufactured From Fortron Material N• Very Easy Removable Lower Part For Cleaning Pipette N• No Discoloration Upon Uv Irradiation N• 3 Years Warranty N• Volume Range - 0.1-2.5 Μl, 0.5 – 10 Μl, 2-20 Μl, 10 – 100 Μl, 100 – 1, 000 Μl ( With Appropriate Tips With Autoclavable Tips Box ) . Ce Ivd Approved N 482 Rpp 483 Petri Plate 484 Brain Heart Infusion Broth Liquid / Media 485 Blood Agar Base 486 Ast- Sensitivity Disc 487 M. A. Agar ( Mac Conkey Agar ) 488 M. H. Agar ( Mueller Hinton Agar ) 489 N. A. Agar 490 Pda ( Potato Dextrose Agar ) 491 Sda 492 Bile Esculine Agar 493 Simmon Citrate Agar 494 Urea Agar 495 Tsi 496 Micro Pipette Stand 497 Tips Filtered 0-100Ul, 20-200Ul & 200- 1000Ul 498 Tips Sterilized 499 Taq Polymerase 500 Dntps ( Datp , Dctp Dgtp Dttp ) 501 Pcr Grade Water ( Nuclease Free Water ) 502 Molecular Filter Tips ( 1Ml , 200Ul ) 503 Normal Tips ( 1Ml 200Ul ) 504 Pcr Buffer ( Tae ) Tris Base, Acetic Acid And Edta 50X / 10X 505 Bromophenol Blue 506 Agarose 507 Nuclease Free Tubes Or Diethylpyrocarbonate ( Depc ) Treated Tubes 508 Ethanol 100% ( Molecular Grade ) 509 Isopropanol ( Molecular Grade ) 510 Qiagen Rna & Dna Extraction Kit ( 250Rxns ) 511 Qiagen Dna Synthesis Kit 512 Molecular Weight Dna Ladder ( 100Bp, 1Kb ) 513 1 % Ethidium Bromide 514 Parafilm 515 Parafilm Cutter 516 Shoes Cover 517 Lab Shoes ( Size 06 .07. 08 , 09, 10 ) 518 Nitrile Gloves ( Size : Small, Medium , Large ) 519 Spray Bottles 520 Hcv Dna Extraction Kit ( Roche ) 521 H1n1 Kit ( Rt Pcr ) 522 Pipette Stands 523 Ph Meter 524 Heat Block 525 Mask- N95 526 Lab Goggles 527 Cryo Gloves ( Small, Medium, Large ) 528 Dna Zap Pcr Dna Degradation Solutions 529 Rna Zap Pcr Dna Degradation Solutions 530 Microcentrifuge Tubes ( Mct ) 1.5Mm, 2Ml 531 S.S.T Tubes ( 5Ml, 10Ml ) 532 Cryovials ( 5Ml ) 533 Cryo Boxes ( 5Ml ) 534 Cryo Vials ( 1.8 Ml ) 535 Cryo Box ( 1.8Ml ) 536 Elisa Kits 537 Toxo Igm- Elisa 538 Toxo Igg- Elisa 539 Cmv Igm – Elisa 540 Cmv Igg – Elisa 541 Rubella Igm- Elisa 542 Rubella Igg- Elisa 543 Hsv-1 Igm- Elisa 544 Hsv- 2 Igm- Elisa 545 Hsv-1 Igg- Elisa 546 Hsv- 2 Igg- Elisa 547 Rota Ag- Elisa 548 Measles Igm- Elisa 549 Mumps Igm- Elisa 550 Ebv ( Epstein-Barr Virus ) Igm- Elisa 551 Hbeag- Elisa 552 Anti- Hbe ( Ab ) - Elisa 553 Hbc Igm ( Ab ) - Elisa 554 Hbc Total Ab –Elisa 555 Anti- Hbs- Elisa 556 Dengue Ns1- Elisa 557 Vzv Igm – Elisa 558 Hdv Total-Elisa 559 Rsv Igm- Elisa 560 Adenovirus Ag- Elisa 561 Norovirus Ag- Elisa 562 Astrovirus 563 Hbsag- Elisa 564 Hcv Ab- Elisa 4Th Generation 565 Hiv Elisa 4Th Generation 566 General Pathology 567 Xylene 568 Isoprophyle Alcohol 569 Paraffin Wax 570 Sprit 571 D.Water 572 Formaldehyde 573 Dpx 574 Hemotoxylline Powder 575 Eosin Powder 576 Hydrochloride Acid 577 Ammonium Sulphate Powder 578 Glycerol 579 Sodium Biocarbonate 580 Magnesium Sulphate 581 Light Green Powder 582 Geimsa Powder 583 Leishman Stain Powder 584 Sodium Nitroproxide 585 Bismark Brown 586 Methanol 587 O.G.6 Powder 588 Mc Grunewald Stain 589 Acetone 590 Acetic Acid 591 Ammonium Sulphate 592 N / 10 Hcl 593 3.8% Sodium Citrate 594 Benidizine Powder 595 Liquor Ammonia 596 Hydrogen Peroxide 597 Foucher’S Reagent 598 Ehrlich’S Aldehyde Reagent 599 Uristrix 600 Combistrix 601 Liquid Paraffin 602 Bendict’S 603 Sodium Citrate 3.2% 604 Sarlon 605 Betadine 606 Tincture Iodine 607 Xylocaine 2% 608 Prothombin Time Kit 609 Aptt Kit 610 Calcium Choride Solution For Aptt 611 Potassium Ferrocynate 612 Normal Saline 613 Periodic Acid 614 Schits Reagent 615 Rbc Fluid 616 Wbc Fluid 617 Platelet Count Fluid 618 Brilliant Cresyl Blue 619 Cell Pack 620 Cell Clean 621 Stromato Lyser Ffs 622 Stromato Lyser Fourth Dl ( 4Dl ) 623 Stromato Lyser Fba 624 Calibrator 625 F2 Check L1l2l3 626 Von Kossa Stain 627 Neutral Red 628 New Methylene Blue 629 Carbol Fuschain 630 Carbo Red 631 Methylene Blue 632 Sudan Black 633 Persian Blue 634 Pas Stain 635 Estrogen Receptor 636 Progestone Receptor 637 C-Erb2 Onco Proton Her2 638 K167 Antigen 639 Cd 3 640 Cd 5 641 Cd 10 642 Cd 15 643 Cd 20 644 Cd 30 645 Cd 34 Endothelial Cell Marker 646 Cd 45 647 Cd 99 648 Cd 117 649 Cd 100P 650 P53 651 Ck-5 / Ck-6 652 Egfr 653 Neuron Specify Enalase 654 Hma 45 655 Myoglobin 656 Pan Cytokeratin 657 Chromogranium A 658 Sma 659 Desmin 660 Vimentin 661 Gfap 662 Synoptophysin 663 Novalink Max Detection System 664 Tris Buffer 665 Ph Paper 2+0.10 666 Leica Blade 818 For Micro 667 Plastic Cassatte Tissue Processor 668 Stal To Lyser Sls 669 Ret Search 670 Cotton 671 Glass Slide 672 Cover Flip 18 X 18 673 Cover Slip 22 X 22 674 Cover Slip 22 X 30 675 Cover Slip 22 X 40 676 Gloves Latex 7.½ & 7 677 Dispo Gloves 678 Saving Blade 679 Scalpel Blade With Handle 680 Swab Sticks 681 Diamond Pencil 682 Wash Bottle 250Ml 683 Wash Bottle 500Ml 684 Tourniquet 685 Urine Pot 686 Pas Reagent – Periodic Acid 687 Schiff’S Reagent 688 Mpo Staining Reagent – Benzidin Power 689 Sodium Nitropreside 690 H2o2 691 Perl’S Staining Reagent – Potassium Feno 692 N / 10 Hcl 693 0.1% Eorin 694 Methanol 695 Neauber’S Chamber 696 Acetone 697 Neutrophil Alkaline Phosphate Reagent- N• Methanol N• Naphthol A S Phosphate ( Sigma N-5625 ) N• 0.2 Mol / L Tris Buffer Plt 9.0 N• N, N- Dimethyl Form Amide ( Sigma D-4551 ) N• Fast Blue Bb Salt N• Neutral Red ( 0.62% Aquor Solution ) N 698 Large Ruler – Metallic Scales 699 Poster Colors For Grossing – Red, Black, Green, Blue Quality Each 700 Scalfil Blade ( Size – 22 & 24 ) 701 Macintosh 702 Surgical Scissors 703 Plastic Gloves 704 Blade For Cryostat ( Frozen ) 705 Pcr – Primer For B Thalassaemia & Sickle Cell Anamia 706 Dna – Extraction Kit 707 Hplc Kit – 3 708 Pentahead Microscope 709 Automated Immnohistochemistry Instrument 710 Defaraffinazation Stand – 8 Jars With Lid 711 Purple Nitrile Gloves 7.5’’ ( Medium ) 712 Plastic Cassettes For Automatic Tissue Procesure 713 Glass Marking Pencil 714 Paraffin Wax ( Granules ) 715 Microtome Blade 716 Wash Buffer Ihc 717 Rubber Teat 718 Hemoglobin Squaretube 719 Hemoglobin Round Tube 720 Capillary Tube 721 Hemoglobin Pipette 722 Tissue Paper 723 Dispo Vial 724 Glass Marking Pencil 725 Glass Marking Pen 726 Naeuber’S Counting Chamber 727 Naeuber’S Counting Cover Slip 728 Hemoglobin Set 729 Rbc Pipette 730 Wbc Pipette 731 Edta Powder 732 Bone Marrow Niddle 16No 733 Bone Marrow Niddle 14No 734 Khaun Test Tube Small 735 Test Tube Big 736 Beaker 1000Ml 737 K3 Vacationer Edta Vial 738 Yellow Rips 739 Bone Marrow Biopsy Needle 740 Sterilizer Medium Size 741 Curtain Stand 742 Coscus Spectum 743 Sponge Lebling Forceps 744 Screen With Stand 745 Auto Pipette 746 Auto Pipette 5-50 Ul 747 Sticker 748 Ret Search 749 Sulfolyser 750 Cytosprin 751 Spectrophoto Meter 752 Automated Staining Machine 753 Cytoprep 754 Cell Counter Six Part Diffrential 755 Semi Auto Biochemical Analyzer 756 Electrolyte Estimation Instruments 757 Electrophoressis ( Capillary ) 758 Semi Auto Coagulometer 759 Ihc Auto Staining Machine 760 Lcd Projector With Laser Printer 761 Calorimeter 762 Steel Almirah 763 Book Self 764 Computer Attachment Ups 765 Paraffin Bath 766 Electronic Balance 767 Auto Meter Esr Machine 768 Centrifuge Machine 769 Glass Rod 770 Poly-L-Lysine 771 Tris Buffer 772 New Methylene Blue 773 Brilliant Crystel Blue 774 Cssd & Laundry Chemical & Consumables 775 Alkyl Alcohol Ethoxilate 20-40%, Sodium Benzoate, 5% Based Emulsifier / Ltr. 776 Disodium Metasilicate Upto 30%, Nonionic Surfactant And Anionic Surfactant Based Powder With Optical Brightner / Kg. 777 Sodium Meta Bi Sulphate 65% Based Rinsing Aid / Kg. 778 Perfumed Liquid Based Softening Agent With Anti Static Property And Biodegradable Having Ph Of 6.5-7.5 / Ltr. 779 Hydrogen Peroxide Of Minimum 30% And Oxygen Based Bleaching Agent / Ltr. 780 Sodium Hypochlorite 5-15% And Sodium Hydroxide Maximum 5% Based Bleaching Agent / Ltr. 781 Sodium Hydroxide Based Liquid Alkali Booster Concentrate. / Ltr. 782 Hydrogen Peroxide And Oxygen Based Concentrated Bleaching Agent Having 23-25% / Ltr. 783 20-40% Phosphoric Acid Based Scale Remover / Ltr. 784 5Th Generation Qac Based Disinfectant Having Didecyl Dimethyl Ammonium Chloride And N Alkyl Dimethyl Benzyl Ammonium Chloride / Ltr. 785 4.25% Ahp Based Surface Disinfectant Concentrate. / Ltr. 786 0.5% Ahp Based High Level Surface Disinfectant Tuberculocidal Wipes / Wipes 787 Protein, Rust, Coffee And Ink Spotting Kit / Kit 788 Acid Based Liquid Neutralizer Concentrate To Be Used With Dosing Pump. / Nos. 789 Solven Liquied / Ltr. 790 Sterilization Packaging Reels 200 Mtrs 10 Cms / Reels 791 Sterilization Packaging Reels 200 Mtrs 20 Cms / Reels 792 Sterilization Packaging Reels 200 Mtrs 40 Cms / Reels 793 Bowie – Dick Compact / Box 794 Documentation Hand Labeler Gun / Nos. 795 Auto Clave Tape / Reels 796 Chemical Indicators Class 6 Steam / Strips 797 S M S Wraps Sheets 75 X 75 Cms / Sheets 798 S M S Wraps Sheets 120 X 120 Cms / Sheets 799 Sterilization Packaging Reels 200 Mtrs 20 Cms / Reels 800 Biological Indicator / Box 801 Eto Indicator / Box 802 Sterilization Indicator / Box 803 Steam Emulating Indicator / Box 804 Plasma Casset / Box 805 Tyvek Roll – 6” / Rolls 806 Tyvek Roll – 10” / Rolls 807 Tyvek Roll – 15.5” / Rolls 808 Eto Thermal Printing Paper / Sheets 809 Eto Cartridge / Nos. 810 Rotary Sealer / Nos. 811 Epson ( Ribbon Cartridge ) / Nos. 812 Auto Clave Print Paper / Sheets 813 Mask / Box 814 Cap / Box 815 Micro Pore / Box 816 Gluffs / Box 817 Betadine / Ltr. 818 Micro Clean / Ltr. 819 Zymokeen / Ltr. 820 Softner Water Kit / Box 821 Salt / Kg. 822 Sprey Gun With Bottle ( 500 Ml ) / Nos. 823 Dental Institute Items 824 Dental Stone - 50Gms 825 Alginate - 50Gms 826 Plaster Of Paris - 50Gms 827 Green Stick - 50Gms 828 Impression Compound - 50Gms 829 Modelling Wax 830 Cold Cure Acrylic – Powder & Liquid - 50Gms 831 Heat Cure Acrylic - Powder & Liquid - 50Gms 832 Teeth Set - 50Gms 833 Spirit ( Burning ) – 500 Ml 834 Acrylic Trimming Burs – Tc - 50Gms 835 Sandpaper ( Coarse And Fine ) - - 50Gms 836 Articulating Paper - 50Gms 837 Sandpaper Mandrel - 50Gms 838 Cold Mold Seal - 50Gms 839 Wool Buff - 50Gms 840 Pumice Powder - 50Gms 841 Polishing Cloth Wheel - 50Gms 842 Gic-Type I - 50Gms 843 Acrylic Trimming Stone - 50Gms 844 Sticky Wad - 50Gms 845 Proprietary Reagents 846 Ca++ Conducting System For Electrolyte Analyser – Model Ecolyte Bio Chemistry Department 847 Variant Ii ( Hplc ) For Department Of Biochemistry & Pathology 848 D-10 ( Hba 1C Analyzer ) For Department Of Laboratory Medicine. 849 Architect I – 1000Sr. Department Of Biochemistry 850 Automated Blood Cell Counter – 5 Part ( Model I Count – 5 ) Department Of Pathology / Lab Midicine 851 Taqman 48 For The Department Of Microbiology 852 V-2 Pcr Reagents For The Department Of Lab Medicine 853 Gel Technology For Blood Bank 854 Bd: Reagents For Phonix 855 Bd: Reagents For Flow Cytometer 856 Bd: Reagents For Migit 960 For Microbiology & Pathology 857 Beg For Haemonetics For Blood Bank 858 Haemotology Analyzer Reagents For Blood Bank 859 Haemotology Analyzer Reagents For Pathology & Lab Medicine 860 Microbiology 861 Cled Agar 862 Ppd 5 Tu – 10Ml 863 Beef Extract 864 Oxidase Discs 865 Lacto Phenol Cotton Blue 866 India Ink 867 Methyl Violet Powder 868 Potassium Iodide Powder 869 Mgit Calibrator Tubes 870 Potassium Dihydrogen Phosphate Gr 871 Sodium Hydroxide Pellets Purified 872 Panta-15Ml 873 N- Acetyl – Cysteine ( Nalc ) 10Gm 874 Tbc Identification Kit -25 875 Pza Drug ( Pyrazinamide ) 876 Pza Media ( Pyrazinamide ) 877 Mgit 960 Suppliment Kit -1X 6 Vials 878 Mgit 960 Sire Kit-40 Test 879 Mgit Barcoded 7Ml Tubes – 100 Vials 880 Tri- Sodium Citrate Dehydrate Purified 881 Di- Sodium Hydrogen Phosphate Dehydrate Purified 882 Conical Falcon Graduated 50 & 15 Ml Tubes 883 Normalizer For B. D Phoenix 884 Gram Positive Panel - B. D Phoenix 885 Gram Negative Panel - B. D Phoenix 886 Ast Broth- B. D Phoenix 887 Indicator - B. D Phoenix 888 Id Broth - B. D Phoenix 889 Ped Plus Bottle – Bd Bactec 890 Anerobic Adult Bottle - B. D Bactech 891 Aerobic Adult Bottle - B. D Bactech 892 Myco F Bottle 893 Hav Igm Elisa 894 Hev Igm Elisa 895 Parvo B-19 Igm Elisa 896 West Nile Virus Igm Elisa 897 Vtm / Utm 898 Hav + Hev Igm Elisa 899 Dengue Ns1 Rapid Kit 900 K Tubes ( Roche ) 901 Pcr Tubes ( 0.2 Ml ) 902 Double Distilled Water 903 Pbs Buffer 1X 904 Superscript Iii One Step Rt Pcr Kit 905 Disposable Bags 906 Biohazard Bags 907 Elisa Reader Thermal Paper 4.2 Inches 908 Silver Foil 909 Ice Tray 910 Cryo Tags 911 Measuring Scoop 912 Gel Scoop 913 Biohazad Wate Container 914 Zero Degree Mini Coolers 915 Somersault Rack 916 Reagent Reservoir 917 Pcr Tube Stand 918 Hbv Viral Load ( Roche ) 919 Hcv Viral Load ( Roche )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
50.
Public Administrative Department #8717141 Technical Bid
Empanelment Of Testing Laboratories For Testing Of Construction Materials ( Civil & Electric Works ) In New Delhi Municipal Council.-1 Bricks / Brick Tiles / Fly Ash Bricks ( A ) Water Absorption 2 Comp Strength 3 Efflorescence 4 Coarse Aggregates ( A ) Gradation ( Sieving ) 5 Crushing Value 6 Impact Value 7 Water Absorption 8 E.I & F.I For Road Works 9 Aggregate. Abrasion Value 10 Specific Gravity 11 Bulk Density 12 Deleterious Materials 13 Organic Impurities 14 Soundness 15 Fine Aggregate ( A ) Silt Content 16 Grading 17 Cement / Opc / Ppc / White Cement / Pozzolana, Etc. N ( A ) Setting Time 18 Compressive Strength 19 Soundness 20 Fineness 21 Consistency 22 Chemical Tests 23 Cc Cubes / Cement Concrete / Rmc ( A ) Comp Strength For 7 / 28 Days 24 C.C Kerb Stones ( A ) Comp Strength 25 Water Absorption 26 C.C Interlocking Pavers ( A ) Comp. Strength 27 Water Absorption 28 Precast Rcc Slabs ( A ) Comp. Strength 29 Manhole Covers With Frame ( A ) Load Test 30 Marble / Granite ( A ) Mohr’S Scale Of Hardness 31 Water Absorption 32 Specific Gravity 33 Ceramic Glazed Tiles ( A ) Modulus Of Rupture / Flexural 34 Water Absorption 35 Chemical Resistance 36 Crazing Test 37 Cc Terrazzo / Chequered Tiles ( A ) Wet Transverse Strength 38 Abrasion Test 39 Water Absorption 40 Lime ( A ) Ca ( Oh ) 2 41 Fineness 42 Water ( A ) Ph Value 43 Limit Of Acidity 44 Limit Of Alkalinity 45 % Of Solid:- N ( A ) % Of Chloride N 46 ( B ) % Of Sulphates 47 ( C ) % Of Suspended Matter 48 ( D ) % Of Inorganic & Organic Solids 49 Chemical Tests Is 3025 50 Rcc Pipes ( A ) Tensile Strength Of Wire 51 Water Absorption 52 Pressure Test 53 Ms, Gi & Ci Pipes ( A ) Tensile Test N N 54 Galvanizing 55 Reinforcement For Rcc ( Physical Tests ) N ( A ) Tensile Test N N 56 ( B ) Bend & Rebend 57 ( C ) Elongation 58 ( D ) Proof Strength 59 Chemical Tests 60 Aluminium For Sections ( A ) Anodic Coating Thickness 61 Flush Door Shutter ( A ) End Immersion 62 Knife Test 63 Glue Adhesion 64 Timber / Wood ( A ) Moisture Content 65 Identification Of Declared Wood 66 Density 67 Road Marking Paint ( A ) Drying Time 68 Finish 69 Colour 70 Resistance To Bleeding 71 Resistance To Wear 72 Flash Point 73 Consistency By Brushing 74 Ready Mix Paint ( A ) Volatile Matter 75 Water Content 76 Scratch Hardness 77 Drying Time 78 Weight In Kg 79 Wet Opacity 80 Consistency 81 Finishi, Colour & Flash Point 82 Flexibility & Adhesion 83 Lead Free Test 84 Resistance To Heat / Acid 85 Protection Against Alkal / Corrosion 86 Thermoplastic Paint ( A ) Drying Time 87 Crazing Resistance 88 Softening Point 89 Binder Content 90 Gloss 91 Lead Content 92 Titanium Dioxide 93 Calcium Carbonate 94 Inert Filler 95 Skid Resistance 96 Luminance 97 Flow Resistnace 98 Yellowness 99 Whiteness 100 Free Flowing Property 101 Gradation Of Glass Beads 102 Synthetic Enamel Paint ( A ) Freedom From Coarse Particles 103 Skin Formation 104 Thinning Properties 105 Application Properties 106 Colour, Gloss & Finish 107 Drying Time & Pigment Content 108 Wet Opacity & Rosin 109 Mass In Kg 110 Flexibility & Adhesion 111 Scratch Hardness 112 Water Content 113 Finenss Of Grind 114 Resistnace Of Acid 115 Resistance To Alkali 116 Consistency 117 Non-Volatile Matter 118 Pvc Pipe ( A ) Hydraulic Test 119 Reversion Test 120 Vacuum Collapse 121 Leakage Of Joint 122 Sulphated Ash 123 Titanium Content 124 Vicat Softening Point 125 Impact Strength 126 Tar Felt ( A ) Breaking Strenght 127 Pliability 128 Storage Capacity 129 Pressure Head 130 Binder Test 131 Heat Resistance 132 Bitumen / Crmb ( A ) Specific Gravity 133 Ductility 134 Viscosity 135 Softening Point 136 Penetration 137 Solubility 138 Loss On Heating 139 Dense Work For Bm / Ac ( A ) Binder Content 140 Density 141 Marshall Stability ( For Ac ) 142 Mix Granding 143 Mastic Asphalt ( A ) Binder Content 144 Hardness Number 145 Premix Carpet / Mix ( A ) Binder Content 146 Gradation 147 Granular Sub Base ( Gsb ) ( A ) Gradation 148 10% Fine Value 149 Atterbergs Limit 150 Proctor Test 151 Cbr Value 152 Field Density 153 Deleterious Material 154 Water Absorption 155 Water Bound Macadam ( Wbm ) ( A ) Impact Value 156 Gradation 157 Combined Ei & Fi 158 Water Absorption 159 Wet Mix Macadam ( Wmm ) ( A ) Impact Value 160 Proctor Test 161 Atterbergs Limit 162 Gradation 163 Ei & Fi 164 Water Absorption 165 Deleterious Materials 166 Field Density 167 Earth Work ( Sub Grade ) ( A ) Moisture 168 Field Density 169 Gradation 170 Atterbergs Limit 171 Proctor Test 172 Cbr Value 173 Acp ( Aluminium Composite Panel ) ( A ) Thickness 174 Density 175 Impact 176 Tensile Strength 177 Stainless Steel ( A ) Chemical Analysis 178 G.I.Pipes ( A ) Tests As Per Is 1239 ( Pt-I ) 179 Structural Steel Up To 25Mm ( A ) Tests As Per Is 2062 180 Structural Steel Above 25Mm ( A ) Tests As Per Is 2062 181 ( I ) Steel Tube ( A ) Tests As Per Is 3601 182 ( Ii ) Steel Tubes ( B ) Tests As Per Is 1161 183 Barbed Wire ( A ) Tests As Per Is 278 184 M.S.Bar & Hd ( A ) Tests As Per Is 432 ( Pt-I ) 185 Cc Core Is 456 / 516 ( A ) Compressive Strength 186 Density Of Core / Thickness 187 Bitumen Core ( Morth ) ( A ) Density 188 Thickness 189 Grading Of Raw Material 190 Admixture Testing Is 9103 ( A ) Ph Value 191 Dry Materials Content 192 Ash Content 193 Relative Density 194 Chloride Content 195 Concrete Mix Design ( A ) ( A ) Mix Design Of Concrete Using Opc / Ppc Cement ( Upto M-45 Grade Concrete ) ( Is 10262-2009 ) N ( I ) With Fly Ash N N 196 ( Ii ) Without Fly Ash 197 ( B )    Mix Design Of Concrete M-50-80 Grade ( Is 10262-2009 ) 198 Job Mix Formula For Dense Bituminous Concrete ( D.B.C ) 199 Job Mix Formula For Dense Bituminous Macadam ( D.B.M ) 200 Job Mix Formula For Mastic Asphaltic Concrete 201 Annealing Test ( For Copper ) 202 Tensile Strength ( For Aluminum ) 203 Wrappint Test ( For Aluminum ) 204 Conductor Resistance Test 205 Dimensions For Armoring Material 206 Tensile Stenght Of Armouring 207 Elongation Test Of Armouring 208 Torsion Test ( Galvanized Steel Wire Only ) 209 Winding Test ( Galvanised Steel Strips Only ) 210 Uniformity Of Zinc Coationg 211 Mass Of Zinc Coating 212 Resistivity Test Of Armouring ( Wire / Strips ) 213 Test For Thickness Of Insulation And Sheath 214 Tensile Strenght And Elongation At Break Of Insulation And Sheath 215 Ageing In Air Oven 216 Hot Set Test 217 Shrinkage Test 218 Water Absorption Test ( Gravimetric ) 219 Loss Of Mass Test 220 Hot Deformation Test 221 Heat Shock Test 222 Thermal Stability Test 223 Insulation Resistance Test 224 High Voltage Test 225 Flammability Test 226 Cold Bend Test 227 Cold Impact Test 228 Flame Retardant Test On Single Cable 229 Temperature Index 230 Oxygen Index 231 Halogen Acid Gas Evaluation 232 Smoke Density Test 233 Ratings 234 Classification 235 Marking 236 Checking Of Dimensions 237 Protection Against Electirc Shock 238 Provision For Earthing 239 Constructional Requirements 240 Resistance To Ageing, To Harmful Ingress Of Water And Humidity 241 Temperature Rise 242 Making And Breaking Capacity Test 243 Normal Operation 244 Mechnaical Strength 245 Resistance To Heat 246 Screws, Current Carrying Parts And Connections 247 Creepage Distances And Clearances And Distance Through Sealing Compound 248 Resistance To Abnormal Heat And Fire 249 Resistance To Rusting 250 Power Input Test 251 Cct 252 Luminous Flux 253 Luminous Efficacy 254 Impulse Test 255 Surge Test 256 Glow Wire Test 257 Leakage Current Test 258 Needle Flame Test 259 Cti ( Tracking Index ) 260 Working Voltage 261 Power Factor 262 Ip Test ( Ingress Protection ) 263 Total Larmonic Distortion ( Thd )
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
TenderDetail
Loading tenders