View Bid Results For Lighting Protection Tenders

We found 2487 Bid Results related to lighting protection tenders. You can find Contractor details who won lighting protection tenders along with contract details in Bid awards announcements section.

Filters
Stage
1845
356
286
Tender Publishing Platform
256
2231
State / UT
36
511
283
271
175
139
110
110
109
103
101
89
59
54
51
43
31
31
29
26
25
22
18
17
15
11
10
10
9
8
5
4
3
2
1
1
1
Contract Value
774
458
953
299
Publish Date
8
2
0
0
0
Sector
31
674
405
295
269
148
135
100
85
59
56
35
34
30
29
26
21
14
9
9
9
8
7
6
6
4
4
3
2
2
2
1
Ownership
6
1193
692
335
248
13
6
Within keyword
Active filters:
Showing 1–50 of 2487 tenders matching your filters
1.
Public Administrative Department #11482340 AOC
Tender For Provision Of Lighting Arrangement With Led Street Lights In Ward No -236 Kardampuri Under Shahdara (North) Zone.; 1 LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LEDfixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driverefficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermalmanagemheat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).72 watt 2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a)Upto 35 sq. mm 3 P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd. 4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 5 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 6 Supply of XLPE insulated PVC Sheathed Al conductor armoured cable 1.1 KV grade conforming to IS-7098 of following size: (a)2x6 Sqmm 7 Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm 8 Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd 9 Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required 10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10KA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a)Single pole
Contract Date: Jun 30, 2026 Contract Value : 4.10 Lakh
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
3.
Public Administrative Department #11469859 AOC
Purchase Of Central Lighting Material And Repairs In Parkal Municipality-12.00 Supply, fixing and transportation of 200 W LED Flood light Luminaire made of pressure die cast aluminum housing with powder coated, having toughened glass cover, Suitable lens on LEDs,IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66 ) protected, wide operating voltage range , P.F > 0.90, System having efficacy >110 lumens/watt, with Ingress protection IP66, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates.LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Surya / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA./ Capart / Fortune Arrt / FIEM / Arraystorm / GM / Goldmedal / Panasonic / Silicon / Leksa / Orient / HPL / Valmont / Transrail LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs 121.00 Supply, Fixing and transportation of LED Driver with input line voltage 120V-270V AC, 50Hz with surge protection of 4.0 KV, IP20, suitable for 90-180W LED street light fitting.MAKES : PHAROX / AVNI / GOLDWYN / KRIPA LIGHTS / Fortune Arrt / STANJO / GREENLITES / TRINIC / PRO-LITE / SCINTILLA / JSTC - SOLAR / INSTA POWER / MILLION / PANASONIC
Contract Date: Ref. Documents Contract Value : 4.18 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 10
5.
Heavy Industries and Public Enterprises #11454168 AOC
Bids Are invited for Custom Bid For Services - Rectification And Interior Modification Of 20 Ft Container For Office Use - Removal, Cleaning, And Re-Fixing Of Existing 2Mm Thick Gi Roofing Sheets Including Dismantling, Stacking, Surface Preparation, Re-Alignment, Fixing With Suitable Welding. , Providing And Fixing Interior False Ceiling Using Pvc Board (Min. 12Mm Thick) With Gi Framework Including Ceiling Sections, Perimeter Channels, Hangers, Fasteners, Joint Finishing And Surface Leveling Complete In All Aspects. , Supply And Installation Of App Modified Bitumen Waterproofing Membrane (Min. 3Mm Thick) Over Container Roof Including Surface Cleaning, Primer Application, Torching, Overlaps, Sealing And Edge Termination Complete In All Aspects. , Supply, And Installation Of Led Tube Lights (22W, 4 Ft) Complete With Fixtures, Internal Wiring And Connections Complete In All Aspects.Preferred Makes: Philips/ Crompton/ Havells Or Equivalent , Providing Complete Electrical Wiring Using Frls Copper Wires From Reputed Brand (1.5 Sq.Mm For Lighting & 2.5 Sq.Mm For Power As Per Site Required Length) In Pvc Conduit Including Saddles, Bends, Accessories And Termination Complete In All Aspects.Materials Shall Be Of Reputed Brand/Manufacturer Such As Polycab, Finolex, Havells, Rr Kabel Or Equivalent, Conforming To Relevant Is Standards And Isi Marked, Wherever Applicable. , Supply And Installation Of Modular 6A Switches From Reputed Brand Including Modular Plates, Flush/Surface Boxes And Wiring Connections Complete In Aspects.Materials Shall Be Of Reputed Brand/Manufacturer Such As Anchor, Legrand, Havells, Schneider Or Equivalent, Conforming To Relevant Standards And Isi Marked, Wherever Applicable. , Supply And Installation Of 6A, 5-Pin Modular Socket Outlets With Plates, Boxes And Wiring Complete In All Aspects.Materials Shall Be Of Reputed Brand/Manufacturer Such As Anchor, Legrand, Havells, Schneider Or Equivalent, Conforming To Applicable Standards And Isi Marked, Wherever Applicable. , Providing Ac Power Point With 20A Socket, Dp Switch, Mcb Protection And Wiring Using 4 Sq.Mm Wire Complete In All Aspects, Conforming To Relevant Standards. , Supply And Installation Of Rj45 Cat6 Io (02 Nos), Io Box (02 Nos), Jack (02 Nos) And Cat 6 Outdoor Cable (30M X 2Nos= 60 Rm) Including Cabling, Termination, Testing And Commissioning Complete In All Aspects. , Supply And Installation Of 4 Way Distribution Box 40 A Including Enclosure Box, Earthing, Termination Etc Complete In All Aspects. , Exterior Painting Including Surface Cleaning, Anti-Corrosive One Coat Primer And Two Coats Of Synthetic Enamel Paint On Outside Of The Containers. , Door And Window Repair Works Including Hinge Replacement, Alignment, Welding (If Required), Locking System Fixing As Per Site Requirement. , Supply And Fixing Of Complete Earth Pit System Comprising 32Mm Dia Gi Pipe (8 Ft. Length), 10 Meters Of Copper Earth Wire, 15 Kg Of Earth Enhancement Chemical, Brick Chamber (450Mm X 450Mm) With Plastering, And Heavy-Duty Manual Cover. The Work Includes Excavation, Installation, Backfilling, Connection, And Testing As Per Is 3043 Or Relevant Standards.
Contract Date: Ref. Documents Contract Value : 1.34 Lakh
Boards / Undertakings / PSU No of Bidders 3
7.
Housing Urban and Rular Development #11440422 Technical Bid
Tender for Providing And Applying Tack Coat With Bitumen Emulsion (Rs-1) Using Emulsion Distributor At The Rate Of 0.25 To 0.30 Kg Per Sqm On The Prepared Granular Surfaces Treated With Primer & Cleaned With Hydraulic Broom As Per Morth Specification Clause 503. , Providing, Laying And Rolling Of Open-Graded Premix Carpet Of 20 Mm Thickness Composed Of 13.2 Mm To 5.6 Mm Aggregates Either Using Viscosity Grade Bitumen Or Emulsion To Required Line, Grade And Level To Serve As Wearing Course On A Previously Prepared Base, Including Mixing In A Suitable Plant, Laying And Rolling With A Three Wheel 80-100 Kn Static Roller Capacity, Finished To Required Level And Grades To Be Followed By Seal Coat Of Either Type A Or Type B Or Type C As Per Morth Specification Clause 510. Case - Ii By Mechanical Means Bitumen (Vg-30) , Providing And Laying Seal Coat Sealing The Voids In A Bituminous Surface Laid To The Specified Levels, Grade And Cross Fall Using Type A, Type B And Type C As Per Morth Specification Clause 511 By Mechanical Means Case - Ii : Type B Bitumen (Vg-30) , Providing And Laying Reinforced Cement Concrete Pipe Np3 For Culverts On First Class Bedding Of Granular Material In Single Row Including Fixing Collar With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2905. 300 Mm Dia , Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (Crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.E Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (As Per I.S.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[Morth Specification : Clause 401]. By Mechanical Means. , Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. , Construction Of Un-Reinforced , Plain Cement Concrete Pavement M30 (Grade), Thickness As Per Design, Over A Prepared Sub Base, With 43/53 Grade Cement As Per Clause 602.2.2 , Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A In Fully Automatic Batching Plant And Transported To Site In Transit Mixer For Having Continous Agitated Mixer, Manufactured As Per Approved Mix Design Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , With All Lead And Lift Including Cost Of Admixtures In Recommended Portion As Per Is 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer In Charge Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Fixed Form Paver And Finished In Continuous Operation Including Provision Of construction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-Days Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (Dowel Bars Will Be Paid Seprately).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
West Bengal View Result →
9.
Educational and Research Institute #11433319 AOC
Procurement Of Tools & Equipment For Newly Established Iti For Girls At Ghatkesar In Medchal Malkajgiri District-25.00 Cost Supply And Delivery Of Cpu: 32 / 64 Bit, 7Th Generation Or Higher, I3 Or Latest Processor, Speed: 3 Ghz Or Higher. Ram: 8 Gb Or Higher, 1Tb Hdd / Sdd, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( As Available In The Market ) . Or All In One Pc Licensed Operating System And Antivirus Compatible With Trade Related Software. Make: Dell. Cost Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of 4Th Gen Ci5 Or Higher Processor, 4Gb Ram, 1Tb Hard Disk, Win8 / Latest Preloaded Licensed Os, 2Gb Graphics Card, Dvd Writer, Standard Ports And Connectors.Make: Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of To Enable Working With Wired Networks For Practical. Make:Finolex. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Broadband Connection With Min. 2 Mbps Speed / Optical Fiber. Make:Optic Fiber. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Registered Domain At Least 100 Mb Web Space. Make: D Link.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of All In One Printer A4 Size. Make: Hp Laser Jet.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dlp Projector With Screen / Multimedia Projector With Screen / Smart Interactive Board / Smart Tv Latest Version. Make:Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Online Ups 5Kva. Make: Utl. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply, Delivery, Installation And Testing Of Open Office Or Equivalent Latest Version. Open Source Software : Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of Python / Java Jdk. Latest Version. Open Source Software : Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of Gimp Or Equivalent. Latest Version. Open Source Software: Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of E Commerce Simulation Software.Latest Version. Open Source Software: Windows. 1.00 Cost Supply, Delivery, Installation And Testing Http Web Server / Xampp Or Any Other Similar Server.Open Source Software: Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of My Sql. Latest Version. Open Source Software: Windows. 4.00 Cost Supply And Delivery Of Air Conditioner 2 Ton. Make: Blue Star.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost For Tools And Eqiupments Of Electronic Mechanic Trade: Cost Supply And Delivery Of Air Conditioner Two Ton Split Ac.Make:Blue Star. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Cro Dual Trace.20 Mhz ( Component Testing Facilities ) . Make: Htc / Varteck. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Battery Charger. 0 - 6 - 9 - 12 - 24 - 48 V, 30 Amp Make:Scientech. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Function Generator Dds Technology Sine Square Triangle Ramp Pulse Serial Data Ttl And Modulation. 1 Mhz -10 Mhz Function- Pulse – Modulation Generator With Built In 40Mhz Frequency Counter.Make:Pacific. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Digital Ic Tester. Dit-02 Make: Krb / Asi / Ssl Make. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Power Electronics Trainer With At Least 6 Numbers Of Application Board Mosfet Characteristics Scr Characteristicsscr Lamp Flasher Scr Alarm Circuit Series Inverter Single Phase Pwm Inverter.Electrical Type Make:Ohm. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 3.00 Cost Supply And Delivery Of Desktop Computers. Cpu: 64 Bit I7 8 Th Gen Processor, Speed: 3 Ghz Or Higher. Cache Memory: - Minimum 3 Mb Or Better. Ram:-8 Gb . Hard Disk Drive: 1 Tb 7200 Rpm ( Minimum ) Or Higher, Wi-Fi Enabled On Board Intigrated Wifi . Network Card:Integrated Gigabit Ethernet ( 10 / 100 / 1000 ) - Usb Mouse, Usb Keyboard And Monitor ( Min. 19.5 Inch ) , Standard Ports And Connectors. Dvd Writer, Speakers And Mic. Licensed Windows 10 Pro Operating System Antivirus / Total Security Preferably Hp / Dell / Lenova. Make:Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Laptop 8 Th Gen I7 Processor, 8Gb Ram, 1Tb Hard Disk, Windows 10 Pro Preloaded Licensed Os, 4Gb Graphics Card, Dvd Writer, Standard Ports And Connectors.Preferably Hp / Dell / Lenova Make:Hp / Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Laser Jet Printer A4 Size.Make:Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Internet Broad Band Connection 300Mbps.Make:Act / Bsnl / Jio. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Electronic Circuit Simulation Software With 6 User Licenses. Circuit Design And Simulation Software With Pcb Design With Gerber And G Code Generation, 3D View Of Pcb, Breadboard View, Fault Creation And Simulation..Make:Edwin. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dso Colour. 4 Channel , 50Mhz Real Time Sampling 1G Samples / Sec, 12 Mpts Memory With Pc Interface Usb, Lan And Math Function Includes +, -, Fft, Differential, Integral, Abs, Log Etc.Make:Aet. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Soldering & De Soldering Station.200 Watt Adjustable.Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Frequency Modulator And Demodulator Trainer Kit.Fm Modulator Type : Reactance Modulator, Varactor Modulator, Vco Based Modulator Fm Demodulator Type All 5 Demodulation Techniques Detailed Teaching And Learning Contents Through Software.Make:Ohm. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Pam Ppm Pwm Trainer Kit Pam - Ppm - Pwm Trainer Kit Is A Uses Natural And Flat Top Sampling Techniques For Modulation And Demodulation Process. Features: Pam-Ppm-Pwm M. Make:Ohm. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Am Fm Commercial Radio Receivers Tr105 Portable Radio Support Fm / Am / Sw / Cb / Vhf / Air Radio Make: Krb Make. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Application Kits For Microcontrollers 6 Different Applications One Set 1.Input Interface : 4X4 Matrix Keypad, Ascii Key Pad, Four Input Switch 2. Display Module 16X2 Lcd, Seven Segment, Led Bar Graph 3. Adc / Dac Module With Most Popular Dc / Dac0808 4. Pc Interface: Rs232 & Usb 5. Motor Drive: Dc, Servo, Stepper 6. Daq: Data Acquisition To Sense Different Sensors Signals. Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Sensor Trainer Kit Containing Following Sensors 1 Thermocouple 2 Rtd 3 Load Cell Strain Gauge 4 Lvdt 5 Smoke Detector Sensors 6 Speed Sensor 7 Limit Switch 8 Photo Sensors 9 Optocouplor 10 Proximity Sensor.Graphical Touch Lcd With Inbuilt Processor For Viewing The Output Waveforms, In Built Daq, And Standard Processing Circuits Like Inverting , Non – Inverting , Power, Current , Instrumentation Differential Amplifier, F / V, V / F, V / I, I / V Converter, Sensors :Rtd, Ntc Thermistor, Lm35 Thermocouple, Gas ( Smoke ) Sensor, Load Cell, Lvdt Sensor, Speed Sensor. Make:Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Different Types Of Electronic & Electrical Cables Connectors Sockets And Terminations 1Mm Sqmm Ti 4Mm Sqmm, 3Pin Socket, 5Pin Socket, Terminal Complet Set. Make:Phenolex. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Fiber Optic Communication Trainer Full Duplex Analog & Digital Trans-Receiver With 660Nm & 950Nm, Noise Generator With Variable Gain, Four Seven Segment Display Ber Counter, Eye Pattern Make:Pacific. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Mobile Phone Trainer. 2G / 3G / 4G Dual Sim Gsm Handset.Frequency Measurement And Band Verification. Real Time Mobile Operation Make:Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Smart Phones Of Different Make ( Android / Windows ) Android / Windows Make:Nokia / Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Lcd Tv ( Trainer Kit ) 21-Inch Full Hd Lcd Color Television Should Support Pal / Ntsc Video Formats Complete Block Diagram Of A Lcd Tv System, Study Board Indicating Various Sections Of Lcd Tv Along With The Test Points And Switch Faults. Make:Sony. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Lcd Tv ( 21 ) Full Hd Telivision. Make:Samsung / Sony. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Led Tv ( Trainer Kit ) 20-Inch Full Hd Led Color Television, Pal / Ntsc Video Formats, Complete Block Diagram Of A Led Tv System, Study Board Indicating Various Sections Of Led Tv Along With The Test Points And Switch Faults Trouble Shooting In Different Sections. Make:Sony. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Solar Training Kit / Simulator With Build In Meters For Dcv Dca Ac Multifunction Meter Frequency Protection Circuits Bs-10 Terminals For Making The Connection Single / Dual Axis Traking System Charge Controller Pwm Based Mppt Charging Stage Bulk Absorptions And Float Make:Trina / Vikram. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Led Lighting System Measurement Of Power, Voltage, Current, Power Factor And Light Output Performance Of Different Lighting Products Like Led, Cfl At Variable Input Voltages 0 To 245V Variable Ac Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Tools And Equipments Of Computer Aided Embroidery And Designing Nsqf: Cost Supply And Delivery Of Over Lock Machine.3 Thread. Make:Juki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Single Head Computerized Embroidery Machine ( Multi Needle ) With Ups Pr1055x. Make:Brother Pr1055x Entrepreneur Pro X Single Head 10 Needle Computer Embroidery Machine. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply, Delivery, Installation And Testing Of Coral Draw Software. 4.00 Cost Supply And Delivery Of Desktop Computer With Ups. Cpu: 32 / 64 Bit I3 / I5 / I7 Or Latestprocessor, Speed: 3 Ghz Or Higher. Ram:-4 Gb Ddr-Iii Or Higher, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( Min. 17 Inch Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Hp / Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Laptop 12Th Generation Inte Core I5 Prosses0r O S Windos 11 Ho 1920*1080 Intel Me 16 Gb Ram, 512 Gb Ssd Hard Drive 35.6 Cm 14 Diognal Fhd. Make:Hp / Dell With Ms Office And Inbuild Windows. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Multi-Functional A3 Size Colour Printer Latest With Trolley. Make: Canon. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Printer Laser Jet Pro M 202Dw. Make: Canon. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Scanner Hp / Dell. Make: Canon. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Automatic Sewing Machine ( With Necessary Attachments ( Zip Fixing, Plcot Gathering Foot Etc. ) ( With Necessary Attachments ( Zip Fixing, Plcot Gathering Foot Etc. ) Make: Zuki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 3.00 Cost Supply And Delivery Of Air Conditioner Of 2 Ton Capacity With Stabilizer. Make:Blue Star.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Computer Set With Ups &Multimedia Projector. Cpu: 32 / 64 Bit I3 / I5 / I7 Or Latestprocessor, Speed: 3 Ghz Or Higher. Ram:-4 Gb Ddr-Iii Or Higher, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( Min. 17 Inch Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Dell / Hp / Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Ac Unit Split Type. 2 Ton Capacity With Stabilizer. Make:Blue Star. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Ac Unit Split Type. 2 Ton Capacity With Stabilizer. Make:Blue Star. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost For Tools And Eqiupments Of Fashioon Design & Technology: Cost Supply And Delivery Of Dress Forms ( Dummies ) Children Ladies Gents ( Fibre ) . Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Computer Set With Ups & Multimedia Projector. Cpu: 32 / 64 Bit, 7Th Generation Or Higher, I3 Or Latest Processor, Speed: 3 Ghz Or Higher. Ram: 8 Gb Or Higher, 1Tb Hdd / Sdd, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( As Available In The Market ) . Or All In One Pc Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Dell / Hp / Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of White Magnetic Board With Felt Board & Accessories Of Size:17X23 ( Fibre With Wooden Frame ) . Make:Roger And Moris. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 25.00 Cost Supply And Delivery Of Sewing Machine - Single Needle Lock Stitch Industrial Model 3 Thread ( Electric Type ) . Make: Juki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Over Lock Machine 3 Thread ( Electrict Type ) . Make:Juki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 24.00 Cost Supply And Delivery Of It Lab With Computers Setup &Installation Along With Ups Required Configuration For Software ( Corel Draw ) Cpu: 32 / 64 Bit, 7Th Generation Or Higher, I3 Or Latest Processor, Speed: 3 Ghz Or Higher. Ram: 8 Gb Or Higher, 1Tb Hdd / Sdd, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( As Available In The Market ) . Or All In One Pc Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Dell / Hp. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply, Delivery, Installation And Testing Of Designing Software Coral Draw. Latest Version Make:Coral. 1.00 Cost Supply And Delivery Of Multi Functional A4 Colour Printer. Printer With Trolly / Table. Make:Hp Laser Jet. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Lcd Projector. Make:Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Vacuum Cleaner.Lab Cleaning ( Latest ) . Make:Euroclean Wd X2 Dry And Wet Vacuum Cleaner. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 List Of Tools And Equipment Of Electrician Trade: Cost Supply And Delivery Of Drill Hand Brace 0-100Mm ( Stainles Steel ) Make:Hudson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Load Bank ( Lamp / Heater Type ) .6 Kw, 3Ph Make:Kohir / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Electronic Components. Consisting Resistors, Diode, Transistor, Ujt, Fet, Scr, Diac, Traic, Igbt, Small. Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 3.00 Cost Supply And Delivery Of Bus Bar With Brackets.1 Mtr Each. Make:Siemens / L &T / Ge. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Rcc Pole With Accessories ( Ms Angle Iron, ‘C’ Clamp, Stay Insulator Etc. ) And Materials.6 Mtr Make:Superior. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Tachometer. Analog Type - 10000 Rpm Make: Metrix / Meco / System. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of G. Auto Transformer Type. Make:Krb / Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Oscilloscope Dual Trace 20 Mhz Make:V A R Tech Ss 5020 B Oscilloscope 20 Mhz Dual Channel Cro. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Oil Testing Kit 230 V, Single Phase 50 Hz 60 Va Output 0-60 Kv Variable. Make:Kiloskar / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Inverter With Battery 1 Kva With 12 V Battery, Input- 12 Volt Dc, Output- 220 Volt Ac Make:Luminous . Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Battery Charger 0 - 6 - 9 - 12 - 24 - 48 V, 30Amp. Make:Elektron . Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Solar Panel With Battery 18 Watt. Make:V-Guard / Exide. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of I5 And I7 Generation Computer Or Latest Version & Instalation 2.8 Ghz & Above, 8 Gb Ram, 500 Gb Hdd, Dvd Combo Drive, 19 / 21” Monitor, Optical Scroll Mouse, Multimedia Keyboard, 32 Bit Lan Card With Upp Port, Necessary Drivers, Etc. Or ( Latest Version ) . Make:Hp / Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ink Jet / Laser Printer. Laser Jet Pro M 202 Dw. Make:Hp / Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of D.C. Shunt Generator With Control Panel, ( With Installation ) .2.5 Kw, 220V &3Phase Squirrel Cage Induction Motor, 5Hp, 440V With Control Panel & Star Delta Starter. Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Motor-Generator ( Ac To Dc ) ( With Installation ) .Squirrel Cage Induction Motor With Star Delta Starter And Directly Coupled To Dc Shunt Generator And Switch Board Mounted With Regulator, Air Breaker, Ammeter, Voltmeter, Knife Blade Switches And Fuses, Set Complete With Case Iron And Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Induction Motor Rating: 7.5 Hp, 415V, 50 Cycles, 3 Phases. Dc Shunt Generator Rating: 5 Kw, 440V ( Output Voltage Varies 110-440V ) Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of D.C. Compound Generator With Control Panel Including Fitted Rheostat, Voltmeter, Ammeter And Breaker, 2.5 Kw, 220V &3Phase Squirrel Cage Induction Motor, 5Hp, 440V, With Control Panel & Star Delta Starterr. Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dc Series Motor Coupled With Spring Balance Load With Instalation. 2.5 Kw, 220 Volts Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dc Shunt Motor 2.5 Kw, 220 V. Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dc Compound Motor With Starter And Switch ( With Installation ) .2.5 Kw , 220 Volts Make:Kbr / Crompton / Kiloskar. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Motor Generator ( Dc To Ac ) Set Consisting Of - Shunt Motor With Starting Compensator And Switch Directly Coupled To Ac Generator With Exciter And Switch Board Mounted With Regulator, Breaker, Ammeter, Voltmeter Frequency Meter, Knife Blade Switch And Fuses Etc. Set Complete With Cast Iron Bed Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. ( With Installation ) . Shunt Motor Rating: 5 Hp, 440V Ac Generator Rating : 3-Phase, 4 Wire, 3.5 Kva, 400 / 230 Volts, 0.8 Pf, 50Cycles Make:Kbr / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ac Squirrel Cage Motor With Star Delta Starter And Triple Pole Iron Clad Switch Fuse With Mechanical Load. ( With Installation ) 5 Hp, 3-Phase, 415 V, 50 Hz Make:Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ac Phase-Wound Slip Ring Motor With Starter Switch. 5 Hp, 440 V, 3 Phase, 50 Hz Make:Krb / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Universal Motor With Starter / Switch. 240 V, 50 Hz, 1 Hp Make:Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Synchronous Motor With Accessories Like Starter, Excitation Arrangements.3 Phase, 3 Hp, 440V, 50Hz, 4 Pole Make:Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Thyristor / Igbt Controlled D.C. Motor Drive With Tacho-Generator Feedback Arrangement ( With Installation ) 1 Hp. Make:Kbr / Havells / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Thyristor / Igbt Controlled A.C. Motor Drive With ( With Installation ) .Vvvf Control 3 Phase, 2 Hp Make:Kbr / Havells / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Three Phase Transformer, Shell Type Oil Cooled With Delta / Star. 3 Kva , 415 / 240 V, 50 Hz Make:Kbr / Havells / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Electrical Machine Trainer – Suitable For Demonstrating The Construction And Functioning Of Different Types Of Dc Machines And Ac Machines ( Single Phase And Three Phase ) . Should Be Fitted With Friction Brake Arrangement, Dynamo Meter, Instrument Panel And Power Supply Unit. Make:Kirlosker / Siemens / Havells / Benn / Energy Pack / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Diesel Generator Set With Changeover Switch, Over Current Breaker And Water / Air-Cooled With Armature, Star-Delta Connections Ac3 Phase, 7.5 Kva, 415 Volt Or Higher Rating Make:Bharath / Mahahendra. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Used Dc Generators-Series, Type For Overhauling Practice 5Kva. Make:Krb / Kirlosker. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Used Dc Generators- Shunt Type For Overhauling Practice 5Kva. Make:Krb / Kirlosker. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Used Dc Generators-Compound Type For Overhauling Practice 5Kva. Make:Krb / Kirlosker. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Pillar Electric Drill Machine Motorized. 12-20 Mm Capacity, 1Hp, 440V, 3 Phase, Induction Motor With Dol Starter, Bench Type. Make:Vimal / Glow. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Motorised Bench Grinder. 1 Hp. 3 Phase, 440V With Dol Starter, Double Side With Smooth And Rough Wheel With Tool Base Make:Bosch / Metro. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ceiling Fan Coil Winding Machine. 250V, 50 Hz, 1-Ф, With Speed Control. Make:Shyam. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Primary Current Injection Set.220V, 50 Hz, 1-Ф, Output Current - 200 A ( Min ) With Timer Make:Krb / Atico. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ev Charger 3 Phase Input. Make:Tata Power Ez. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ev Charger ( Home ) 1 Phase Input. Make:Tata Power Ez. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Working Bench. 2.5 M X 1.20 M X 0.75 M ( Iron ) Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete.
Contract Date: Ref. Documents Contract Value : 1.12 Crore
Government Departments No of Bidders 1
10.
Housing Urban and Rular Development #11432190 Price Bid
Tender for 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq M On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. - All Kinds Of Soil , 2.25Filling Available Excavated Earth (Excluding Hard Rock/Ordinary Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , 2.27Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , 4.1.4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1 :2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mmnominal Size) , 4.17Making Plinth Protection 50 Mm Thick Of Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand (Zone-Ill) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] , 5.33.1.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.33.2.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases For Columns , 5.9.5Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.21Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , 6.1.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 7.1.1Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1 :6:12 (1 Cement: 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 8.14.4.1Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1 :2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :White Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 70 Mm Thick , 8.25.1Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 40 Mm Thick , 8.25.4Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , 10.16.1Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , 10.25.1Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , 11.41.2Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , 12.34Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg I M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm)@ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , 12.50Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , 12.51.2 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Flashings/ Aprons.( Upto 600 Mm) , 12.51.6 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Gutter (600 Mm Over All Girth) , 13.50.2Applying Priming Coat: With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood , 13.50.3Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , 13.62.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , 13.68.1French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , 16.69 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer In-Charge (Length Of Finished Kerb Edging Shall Be Measured To Calculate Volume For Payment). (Precast cement concrete Kerb Stone Shall Be Approved By Engineer-In-Charge). , 16.92Providing And Fixing 10X10x7.50 Cm Granite Stone Block Hand Cut And Chisel Dressed On Top, For Paving In Floors, Drains Etc. Laid Over 20 Mm Thick Base Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints 10 Mm Wide Filled With Same Mortar Including Ruled Pointing Etc. Complete As Per Direction Of Engineer-In-Charge. , 1-2Excavationinfoundationfor Retaining,Breastwallsetc, Inall Typesofsoils And Rocks Includingall Lead, Lift Anddisposal Of Surplusmaterial Asper Direction Of Engineer- In- Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , 1-4 Randomrubblestonemasonry Laid In1:6Cement Andsandmortar, In Breastwalls,Retainingwalls,Parapets,Scuppers,Etc. Includingsupplyofall Material, Labour, T&Pand Royaltiies Etc. Complete As Per Drawingand Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , 1-3 Randomrubblestonemasonry Laiddry, Inbreastwalls, Retainingwalls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Completeasper Drawingand Technical Specificationsclauses702, 704, 1202 & 1203 Of Mord Specifiction , 1-5 Handpackedstonefillinginbackofwallls Includingcostofallmaterials, Royality,T&Petc.Completeasperdirectionofengineer-In-Charge. (Asper Pwd Uttarakhand Specifications) , 2-2Concretewithcement, Coarsesandand40mmgaugestoneballast In Proportion1:4:8 In Foundationsand Floors Includingsupplyof Allmaterial, Labour Andt&Petc. Required For Proper Completionof Thework. Asper Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , 3-7Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgradereplacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2As Per Technical Specification Clause 302.3.11 , 12-9Providing Weepholes In Brick Masonry/Stone Masonry, Plain/Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Providing & Supplying Of 25W Self Ballasted Led , Providing & Supplying Of Decorative Lighting Pole Of 4M , Providing & Fixing Of Aayush Wellness Based Signages/Boards Including Vertical Pole & Ms Sheet , Providing & Fixing Of Aayush Wellness Based 3D Paintings With Pop Texture Including Texture Paint
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
11.
Defence #11427184 Technical Bid
Tender for Sch A Part-I To Xi Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Internal Water Supply) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (Sewage Disposal ) , Total Amount Of Sch A Part-Ix (External Water Supply) , Total Amount Of Sch A Part-X (External Electric Supply) , Total Amount Of Sch A Part-Xi (Hot Water Supply) , Schedule A Part-Xii (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , Supply And Fix Engineering Body Desert Cooler Electric Driven Single Phase 230 Volts, Having Nominal Air Flow Capacity Of 4500 Cum Per Hour,Tank Capacity 105 Ltrs,With Auto Louver Movement,With Min Ait Throw 15 Mtr Complete All As Specified And As Directed By Engr-In- Charge. Make:Kenstar Turbocool Neo Hc 105 Or Techno Commercial Equivalent Make. , Supply, Installation, Commissioning Refrigerator, Electric Driven (Single Phase),Capacity 340 Ltrs , Double Door, Smart Inverter Compressor Of Latest Model, Eco Friendly , Digital Display, Toughened Glass Shelves Complete With All Accessories All As Specified And Directed By Engineer In Charge. , Supply Installation, Commissioning Of Metal Top Deep Freezer Double Door Single Phase Storage Type Deep Freezer 320 Ltrs Cap Of Latest Model Complete With All Accessories All As Specified And Directed. , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva All As Specified And Directed , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. , Design, Fabricate, Supply, Install, Testing And Commissioning Of Complete Electrical Chimney/Electrical Hood With Filters Comprising Of Following Items. A) Supply,Install,Testing And Commisssioning Of Kitchen Hood Made Ss 304 Matt Finish 1 Mm Thick Wall Mounted Type With Removable Grease Stop And Fixing Brackets,Oil Drain Channel Of Size 36 X 72 Of Required Length Including Drain Collector & Connecting With Exhaust Ducting Etc Complete All As Specified And As Directed-2 Rm B) Supply And Install Removable Grease Stop Filters Suitable Size Complete All As Specified And As Directed- 02 Nos C) Supply,Install,Testing And Commissioning Exhaust Blower Of Capacity 1 Hp ,240 Volts Single Phase 1440 Rpm Connecting With Exhaust Ducting And Suitable Copper Cable Connecting Complete All As Specified And As Directed:-01 Nos D) Supply And Installation Collar Damper Of Suitable Size For Connecting Between Duct And Exhaust Hood Made Out Of 20 Swg Complete All As Specified And As Directed.-02 Nos E) Supply And Fix Anti Vibration Dush With Ms Fabricated Stand Frame Of Suitable Size For Resting Blower Complete All As Specified And As Directed. , Supply And Install Exhaust Ducting Of Size 500 Mm X 500 Mm Made Of Gi Sheet 24 Swg Including Connecting With Ceiling Mounted Exhaust Hood Up To Terrace With Ms Angle Frame 25 X 25 X 3 Mm Thick,Fixing Of Brackets With Nut Bolts,Gaskets Supporting Thread Rod,Channels Etc,Including Painting The Steel Surfaces With Two Coats Of Synthitic Enamel Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Taps, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly Nuts Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S&F Health Faucet (Abs Body) Suitable For 15 Mm Dia Pipe With 1 Metre Long Flexible Tube And Abs Wall Hook Including Making Connections And Fixed In Position Complete In All Respect As Specified. , S&F Two Way Bib Tap 15Mm Dia, With Wall Flange And Aerator Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. , S&F Wall Mixer For Mixing Hot And Cold Water And Bend For Connecting To Shower,15 Mm Bore Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. , S & F Flush Cock, Push Type 15Mm Dia, Cast Copper Alloy, Fancy Type, Chromium Plated, For Iron/Cpvc Pipe Or Unions Complete All As Specified And As Directed. , S&F 15 Mm Bore Pillar Tap With Swan Neck, Cast Copper Alloy With Capstan Heads, Fancy Type, Chromium Plated Screwed Down With Long Screwed Shanks And Fly Nuts Screwed For Iron/Cpvc Pipe And Fixed Complete All As Specified And As Directed. , S & F In Replacement Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , S & F Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 10 Watt With Led Light Source 6500K With Uniform Light Output,With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb Four Pole 25 Ka, 100 annual periodical maintenance With Fixed Thermal And Magnetic Settings As Incomer Ip43 Protection Double Door : Plain 4 Way With Suitable Rated Busbar,Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separetely. , S&F In Replacement, Mccb 4 Pole, 415 V, Adjustable Type, 100 Amps With Breaking Capacity 25 Ka And Making Connection With Suitabl Size Of Copper Lugs Etc Complete All As Specified And As Directed. , M&L For Construction Of New Reinforced Cement Concrete Septic Tank For 50 Users Designed To Carry Sewage And Sludge Water, Plain Cement Concrete 1:4:8 Below Foundation, Reinforced Cement Concrete Roof Slab Including Beams, Etc, Using Tmt Crs Bars Grade Fe-500D/Fe-550D, With Vent Shaft , Manhole Opennings With Cover Connection, Including Excavation Earthwork In Any Type Of Soil/ Ordinary Rock Complete All As Shown On Td Drg. Afb/Td/228/2018(S) Sheet 1R/1 Of Ce (Af) Bangalore Zone And As Specified By Engineer-In-Charge. , M&L For Construction Of Soakage Well, Including Excavation In Any Type Of Soil/Ordinary Rock, Foundation In Plain Cement Concrete 1:3:6 Walls Of Honeycomb Masonry With Top Ring Of M-25 Concrete Including Intersepting Chamber Screen Chamber Made Of Fly Ash Brick Masonry In C:M 1:4, Rcc/Dwc Complete Filled With Brick Bats Of Size Of Size 1.80M Dia And 3.0 M Effective Depth All As Shown On Drawing No Cepz/2019/Td/03 Sheet No 1/2 And 2/2 And As Specified By Engineer-In-Charge. , S&F Of Grease Trap Of Capacity 500Lts Having Length X Width X Height Of 1150 X 939 X 765 Mm, To Be Installed Underground Complete All As Specified And As Directed By Engineer-In-Charge. Make : Supreme, Cat No Rlugtp0500gb And Equivalent Series As Approved By Engineer-In-Charge. Note: (A) Excavation, Plain Cement Concrete And Brickwork For Installing Grease Trap To Be Paid Separately Under Respective Items. , Cutting Existing 150 Mm Dia Di Pipe For Inserting Tee Of Size 150X150x50 Mm Including Lead Joint And Excavation Etc Complete All As Specified And Directed , M&L For Construction Of Valve Pit/Chamber Of Internal Dimensions 900 Mm X 900 Mm X 900 Mm, Using Plain Cement Concrete 1:4:8, Type D-2, Using 40Mm Graded Stone Aggregates For Foundation, 23 Cm Thick, Brick Wall Built In Cement Mortar (1:4) ,15 Mm Thick Rendering All Around The Brick Work In Cement Mortar (1:6), 75 Mm Thick Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregates In Coping Including Necessary Form Work, 3 Coats Of White Wash On Rendered Surfaces And On Coping, 5 Mm Thick Mild Steel Top Sheet Cover With Frame Made Out Of 40X40x6 Mm Angle Iron, Locking Arrangement, Including Painting Of Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 1.52 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
14.
Civil Aviation #11410905 AOC
Bids Are invited for Operation Of Bhs Including Supply Of Spares And Decorative Lighting At Mvi Airport Ayodhya Boq Item No. 1 - Operation Of Baggage Handling System ( Both Arrival And Departure ) By Engaging Following Minimum Man Power. A) Electrician Cum Operator/ Technician - Skilled - 04 Nos ( All Days Including Weekly Offs & Holidays).B) Skilled - 01 No. For Data Entry & Other Miscellaneous Work (In General Shift For Six Days In A Week )Note- Contractor Has To Provide Reliever On Weekly Offs / Holidays Of Above Required Staffs Except For Sl. No. B) , Boq Item No. 2 - Supply Of Red Outer Lens For Rwy End Light Suitable For Existing Airfield Ground Lighting System (Agl) Complete As Required .( Existing Light Fixture Is Of Vardhman Make ) , Boq Item No. 3 - Supply Of Green Outer Lens For Rwy Threshold Light Suitable For Existing Airfield Ground Lighting System (Agl) Complete As Required .( Existing Light Fixture Is Of Vardhman Make ) , Boq Item No. 4 - Supply Of Yellow Filter For Runway Edge Light Suitable For Existing Airfield Ground Lighting System (Agl) Complete As Required .( Existing Light Fixture Is Of Vardhman Make ) , Boq Item No. 5 - Supply Of 200W, 6.6/6.6A Halogen L Pk30d(64382 Hlx-C) Make - Osram Or Equivalent Suitable For Existing Agl/ Cat-I Fittings Complete As Required . , Boq Item No. 6 - Supply Of Isolating Transformer Of 200 Watts, 6.6A/6.6A, 5Kv, 50 Hz Suitable For Existing Agl/Cat-I Light Fixtures Complete As Required. , Boq Item No. 7 - Supply Of Wind Socks (Cloth) For Wdi(White/Red) Suitable For Existing Sgs Make Wind Sock. , Boq Item No. 8 - Supply Of 360 Degree Outer Clear Lens For Runway Edge Light Fitting Suitable For Existing Light Fixture Of Vardhman Make. , Boq Item No. 9 - Supply Of Clear Spreader Lens For Approach Light Fitting Suitable For Existing Light Fixture Of Vardhman Make. , Boq Item No. 10 - Supply Of Clear Lens For Papi Suitable For Existing Papi System Of Vardhman Make. , Boq Item No. 11 - Supply Of 2Cx 4 Sqmm. Annealed Tinned Copper Conductor Pvc Insulated Pvc Sheathed Unarmoured Flexible Afl Secondary Lead Up To Voltage Garde 1.1 Kv Conforming To Relevant Is Up To Date Ammendment Complete As Required. , Boq Item No. 12 - Supply Of Minimum 9 W Led Type Aviation Obstruction Light In Red Colour Having Die-Cast Aluminum Housing With Red Polycarbonate Dome For Better Illumination, Integral Driver, Ingress Protection - Ip65 (Make- Bajaj Or Equivalent As Approved By Eic) , Boq Item No. 13 - Supply Of 30 W Movable Led Flood Light (Yellow Colour) (Make - Philips , Type - Bvp102 30 Or Equivalent) Complete As Required At Site. , Boq Item No. 14 - Supply Of 150 A, 1000V, 50 Sq. Mm Terminal Block Suitable For Mounting On Din Rail Suitable For Existing Panel Complete As Required At Site. , Boq Item No. 15 - Supply Of Led Driver Of 80W, 25 V Suitable For Existing Airfield Signage Board (Make-Electrosystem) Installed In Operational Area Complete As Required At Site. , Boq Item No. 16 - Supply Of 15 W Led Suitable For Existing Taxiway Light Fitting Of Vardhman Make Complete As Required At Site. , Boq Item No. 17 - Supply Of Electronic Driver Suitable For Existing 15 W Led Taxiway Light Fitting Of Vardhman Make Complete As Required At Site. , Boq Item No. 18 - Supply Of Mnx 70 Type 3 Pole Power Contactor Having Ac-3 Duty, 70A Rating, Ac1 -100 A Rating, Coil Voltage- 230V Ac, Suitable For Lighting Switching Applications, Panel Mounting, Conforming To Conforming To Is/Iec 60947-4-1 Etc. Complete As Required. , Boq Item No. 19 - Supply Of Isi Marked, Heavy Duty, Rigid Pvc Conduit, Size- 25 Mm Dia, Confirming To Is 9537 (Part 3) Complete As Required At Site. , Boq Item No. 20 - Supply Of National Flag Of Size 9144 Mm X 6096 Mm As Per Bis Specification No Is 1-1968 Latest Complete As Required At Site. , Boq Item No. 21 - Supply Of 18 Mtr Length Tri-Colour Led Rope Light Having Transparent Pvc Type Body Material, Ip65 Protection, Smd Led Strip As Per Lm 80/Is16106, Conforming To Is 10322 And Suitable For Operation On 240 V, 50 Hz Single Phase Power Supply Complete As And When Required. (Make-Philips/Halonix/Crompton/Bajaj/Osram) Total Quantity : 2123
Contract Date: Ref. Documents Contract Value : 66.89 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
18.
Public Administrative Department #11390437 AOC
Providing Wiring And Electrical Items For Anganwadi Schools At Ramannapeta In Division No. 60 In Khammam Municipal Corporation-1. Electrical Wiring Installation Is 732-1989 ( System Voltage Not Exceeding 650 V ) 2. Graphical Symbols Used In Electro-Technology Is 2032-1969 Art-Xi-Electrical Installation Buildings. 3. Fire Safety Of Building ( General ) Electrical Installation Is 1646-1961 4. Pvc Insulated Cables Is 694-1977 5. Pvc Insulated Cables ( Heavy Duty ) Is 1554-1964 6. 5 A Tumbler Switches Is 1087 7. 15A Tumbler Switches Is 2120 8. 3 Pin Plugs And Sockets Is 1293 9. Aluminum Conductors For Insulated Cables Is 1753-1967 10. Recommended Current Ratings For Cables Is 1961-1967 11. Installation And Maintenance Of Paper Insulated Is 1155-1967 Power Cables 12. Earthing Is 3043-1966 13. Rigid Steel Conduits For Electrical Wiring Is 9537-Pii-1989 14. Fittings For Electrical Wiring Is 2667-1964 15. Flexible Steel Conduits Electrical Wiring Is 3430-1966 16. Accessories For Rigid Steel Conduit Insulated Cables Is 3837-1966 17. A C Circuit Breakers Is 2516-1977 18. Heavy Duty Airbreak Switches And Fuses For Is 4047-1967 Voltage Not Exceeding 1000V 19. 11 Kv Xlpe Cables Is 7089-Part-Ii 20. Fuses Is 9224-P-I & Ii 21. Current Transformers Is 2705 22. Voltage Transformers Is 3516 23. Indicating Instruments Is 1248 24. Relays Is Is - 722 25. Integrating Instruments Is Is - 3231 26. Auxillary Contracts Is 2959 27. Auxillary Switches And Push Buttons Is 6875 28. A C Isolators And Earthing Switches Is 1818-1972 29. Central Gear For Voltage Not Exceeding 1000 V Is 4337-1967 30. Installation And Maintenance Of Switchgear Is 3072-1965 31. Enclosed Distribution Fuse Board And Cutouts Is 2675-1964 For Voltage 100 V 32. Airbreak Isolators For Voltage 1000 V Is 2607-1976 33. Marking Alignment Or Switchgear Bushers Main Is 375-1963 Connections And Auxillary Wiring 34. Selection Installation And Maintenance Of Fuses Is 3106-1966 ( Voltages Not Exceeding 650 V ) 35. General And Safety Requirements For Electric Is 1913-1969 Lighting Fittings 36. Lighting Public Thorough Fares Is 1944-1970 37. Waterproof Electric Lighting Fitting Is 3528-1966 38. Water Tight Electric Lighting Fittings Is 3553-1966 39. Luminaries For Street Lighting Is 2149-1970 40. Mild Steel Tubulars And Other Wrought Steel Is 1239-1968 Pipe Fittings 41. Ceiling Fans Is 374-1951 42. Transformers Is 2026-1962 43. Installation And Commissioning Of Transformers Is 1886-1967 44. Protecting Of Buildings And Allied Structures Is 2309-1967 Against Lighting 45. Interior Illumination Is 3636-1966 46. Busbar Ratings Is 8084-1976 47. Onload Change Over Switches Is 4064-1978 48. Alluminium Alloy For Bus Bars Is 5082 49. Factory Built Assemblies Of Switchgear And Is 8623 Control Gear 50. General Requirements Of Switchgear And Control Gear Is 4237 For Voltages Not Exceeding 1000 V. 51. Degree Of Protection Provided By Enclosing For Low Is 2147 Voltage Switchgear
Contract Date: Ref. Documents Contract Value : 1.69 Lakh
Local Bodies No of Bidders 1
20.
Public Administrative Department #11355718 AOC
Tender for Annual Tender 2026-27 Supply Of Electrical Goods For The Year 2026-27 , 4 Feet Flourescent Tube Light , 36W / 40W Tubelight Electronic Choke , Tube Light Side Lock Holder , Insluation Gum Tape Roll - Isi , 1/18 Vir Copper Wire [1/44] [90Mtr] , 3/20 Cts Copper Wire [3/36] [90Mtr] , 7/20 Cts Copper Wire [7/34] [90Mtr] , 7/16 Cts Copper Wire [7/67] [90Mtr] , 19/16 Cts Copper Wire [19/51] [90Mtr] , 1.5 Sq.Mm 3 Core Copper Cable , 2.5 Sq.Mm 3 Core Copper Cable , 4 Sq.Mm 3 Core Copper Cable , 6 Sq.Mm 3 Core Copper Cable , 10 Sq.Mm 3 Core Copper Cable , 16 Sq.Mm 3 Core Copper Cable , Led Fitting Top Protection Glass - Street Light , Led Fitting Top Protection Glass - Flood Light , 32 / 40 Mm 1 No Gi Bend Pipe, With 2Nos Of Pole Clamps With Bolts And Nuts , 6Amps To 32 Amps Sp Mcb , 40Amps 2Pole Isolator , 63Amps 4Pole Isolator , 32A D.P Switch , Mcb Box , Fuse Unit 16 Amps 240V , Fuse Unit 32 Amps 415V , Fuse Unit 63 Amps 415V , Fuse Unit 100 Amps 415V (Heavy Duty) , Fuse Unit 200 Amps 415V (Heavy Duty) , Fuse Unit 300 Amps 415V (Heavy Duty) , Fuse Unit 400 Amps 415V (Heavy Duty) , Fuse Unit 500 Amps 415V (Heavy Duty) , Main Switches Spn 32 Amps , Main Switches Tpn 32 Amps , Main Switches Tpn 63 Amps , Main Switches Tpn 100 Amps , Main Switches Tpn 315 Amps , 63A 4Pmc Changeover Switch , 100A 4Pmc Changeover Switch , Automatic On/Off Street Light Timer Switch With 24Hrs 7 Days Programable Digital Timer Clock, 40 Amps 4 Pole Contactor With Coil, Mcb Switch And Connector Fully Wired With All Accessories , Street Light Meter/Main Box With Wooden Board, Main Switch, Fuse Carrier Fully Wired With All Accessories , Electronic 7 Days 24 Hrs Programable Ditial Timer Clock , 63 Amps 4 Pole Contact With Coil , 220V - 250V Contactor Coil , Power Capacitor , 9W Led Bulb , 20W High Bright Led 4 Feet Light , 20W Led Power Saver Street Light Fitting , 25W Led Power Saver Street Light Fitting , 30W Led Power Saver Street Light Fitting , 36W Led Power Saver Street Light Fitting , 50W Led Power Saver Street Light Fitting , 60W Led Power Saver Street Light Fitting , 72W Led Power Saver Street Light Fitting , 90W Led Power Saver Street Light Fitting , 150W Led Power Saver Flood Light Fittings , 200W Led Power Saver Flood Light Fittings , 60W All-In-One Solar Led Street Light Fittings , 80W All-In-One Solar Led Street Light Fittings , 18W To 25W Led Chip Board , 30W To 36W Led Chip Board , 45W To 60W Led Chip Board , 72W To 90W Led Chip Board , 120W To 200W Led Chip Board , 18W To 25W Led Heavy Duty Electronic Driver , 30W To 36W Led Heavy Duty Electronic Driver , 45W To 60W Led Heavy Duty Electronic Driver , 72W To 90W Led Heavy Duty Electronic Driver , 120W To 200W Led Heavy Duty Electronic Driver , 10 Kv Surge Protector , 48 Ceiling Fan With All Accessories , D.O.L Motor Starter Up-To 10 Hp , G.I Swaged Tubler 6 Meter Pole With 60W All-In-One Solar Street Light Model Fitting With One Year Warranty, [All-In-One Model Includes 100W Solar Panel, 60W Led Mcpcb, In-Built Li-Thium Battery, Dusk To Dawn Driver Controller, Sensor, Heavy Duty Clamping Arm In A Suitable Ip65 Rated Enclosure] , 10Metre Hot Dip Galvanised Octogonal Pole With Round Ring Arm And 4Nos Of Strong 5Feet Anchor Bolts, Templates, And Nuts Etc.. Complete Set , 1 Hp To 3Hp Single Phase Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 5 Hp To 7.5Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 10 Hp To 25Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , Service Charges Automatic On/Off Street Light Timer Switch Box , Service Charges For Mini Mast Lighting System , Service Charges For High Mast Lighting System
Contract Date: Jun 24, 2026 Contract Value : 3.87 Lakh
Local Bodies No of Bidders 2
23.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
25.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
26.
Public Administrative Department #11317492 Technical Bid
Tender For Distribution Of Electrical Spare Parts Required For Street Lighting And Municipal Buildings- 1 4 Feet Flourescent Tube Light 2 40W Copper Choke 3 40W Tube Light Starter 4 36W / 40W Tubelight Electronic Choke 5 Tube Light Side Lock Holder 6 Insluation Gum Tape Roll - Isi 7 1/18 Copper Wire Pvc To Pvc 8 3/20 Copper Wire Pvc To Pvc 9 7/20 Copper Wire Pvc To Pvc 10 1.5 Sq.Mm 3 Core Copper Cable 11 2.5 Sq.Mm 3 Core Copper Cable 12 4 Sq.Mm 3 Core Copper Cable 13 Led Fitting Top Protection Glass - Street Light 14 20 / 25 Mm 1 No Gi Bend Pipe, With 2Nos Of Pole Clamps With Bolts And Nuts 15 32 / 40 Mm 1 No Gi Bend Pipe, With 2Nos Of Pole Clamps With Bolts And Nuts 16 6Amps To 32 Amps Sp Mcb 17 40Amps 2Pole Isolator 18 63Amps 4Pole Isolator 19 32A D.P Switch 20 Mcb Box 21 Fuse Unit 16 Amps 240V 22 Fuse Unit 32 Amps 415V 23 Fuse Unit 63 Amps 415V 24 Main Switches Spn 16 Amps 25 Main Switches Tpn 16 Amps 26 Main Switches Spn 32 Amps 27 Main Switches Tpn 32 Amps 28 Main Switches Tpn 63 Amps 29 Automatic On/Off Street Light Timer Switch With 24Hrs 7 Days Programable Digital Timer Clock, 40 Amps 4 Pole Contactor With Coil, Mcb Switch And Connector Fully Wired With All Accessories 30 Street Light Meter/Main Box With Wooden Board, Main Switch, Fuse Carrier Fully Wired With All Accessories 31 Electronic 7 Days 24 Hrs Programable Ditial Timer Clock 32 63 Amps 4 Pole Contact With Coil 33 220V - 250V Contactor Coil 34 20W High Bright Led 4 Feet Light 35 150W Led Power Saver Flood Light Fittings 36 40W All-In-One Solar Led Street Light Fittings 37 60W All-In-One Solar Led Street Light Fittings
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
27.
Public Administrative Department #11314944 AOC
Tender for Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole Cap Etc Supplying Of Swaged Steel Tubular Pole As Per Is 2713, Pt. Ii, 1980 For Following Designation And Of Following Dimensions.(Outside Dia & Thickness Are Given In Annexture -1)H) 410 Sp - 24 ; 8.5 Mtr., 158.00 Kg. , Schedule Of Rates For Oh Line Installation (Lt Distribution).Erection Of Poles.Erection Of Single Steel Tubular Pole Of Length As Given Below With/Without Sole Plate & Cap Etc. In cement concrete Foundation (Proportion And Dimension Indicated Below), Having 600X600x150 Mm Thick cement concrete (4:2:1) Base Block Below Sole Plate/Pole With Hard Jhama Metal Including cement concrete (6:3:1) Muffing 0.30 Mts. Dia And 0.30 Mts. Above Ground Level Including 3 Mm Thick Neat Cemented Finish And Gi Earth Bolt After Making Drilled Holes Etc. On Pole & Carriage Of Pole Upto 1.6 Km From Store To Work(Site Including Filling Up The Excavated Earth Pit With Shifted Soil And Ramming Properlyupto 9.0 Mtr. Size 0.6X0.6X1.70 Mts , Schedule Of Rates For Earthing Installations.Soil Excavation.Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming.For Morrum Soil. , Schedule Of Rates For Earthing Installations.Earthing Installation ... With Pipe Electrode.Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below:(A)By Isi Medium Gi Pipe. , Schedule Of Rates For Overhead Line Installation - Repair 13. Providing cement concrete (6:3:1) Muffing 450X450x600 Mm In Size Or Equivalent Size Of Cylindrical Muffing Above Ground Level Around The Pole Base Complete With 3 Mm Thick Neatly Finished Cement Plaster All Round After Dismantling The Unservicea
Contract Date: Jun 19, 2026 Contract Value : 1.99 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
28.
Housing Urban and Rular Development #11311754 Technical Bid
Tender for 1. Sculpture - MahobaS Betel Leaf - Technical Specification Desiging, Providing, Fabricating, And Installing 10 Ft High (7 Ft Sculpture + 3 Ft Plinth) Frp Sculpture, Executed In Premium-Grade Uv-Stabilized Frp Laminates Minimum 8 Mm Thick, Manufactured Using Chopped Strand Mat (Csm) 450 Gsm And Woven Roving 600 Gsm With Iso-Grade Resin System, Gelcoat Finish And Polymer Hardener. Frp To Be Formed Over A Fabricated Ms Structural Armature Using Ms Square/Round Pipe Section (Minimum 50×50×2.5 Mm Thick), Including Full Welding, Grinding, Stress-Relief, And Two Coats Of Zinc-Rich Epoxy Primer Followed By Polyurethane (Pu) Topcoat On Metal Elements. Surface Finishing To Include Mirror-Finish Inlays Fixed With Industrial-Grade Adhesive As Per Approved Motif Layout And Embedded Bundelkhandi Folk Motifs Engraved Or Cast Within Frp Layer. Plinth To Be Constructed In M-20 Grade Reinforced Cement Concrete With Reinforcement Confirming To Is:456, Shuttering With Waterproof Ply, Finishing, And Integrated Chemical Anchor Bolts (Hilti/Equivalent) For Anchoring Ms Frame To Rcc. Plinth Outer Surface To Be Clad In Polished Red Sandstone 20-25 Mm Thick, Machine-Cut, Fixed Using Stainless Steel Cramps/Clamps (Grade 304) And Polymer-Modified Adhesive With Pointing In Pigment-Matched Epoxy Grout. Brass Nameplate (8-10 Mm Thick) With Deep-Engraved Lettering To Be Installed With Countersunk Ss Screws. Electrical Work Includes Rgb Uplighters (2 Nos. - Ip67, Ik08) With In-Built Charge Controller, Panel Mounting Brackets, Concealed Wiring With Uv-Resistant Cable, Junction Boxes, And Testing. Rgb Lighting System: Providing And Laying Programmable Rgb Led Linear Strip/Flood Lighting, Ip65-Rated, High-Power 5050/3528/2835 Chipset, With Aluminum Channel Fixing, Silicone Encapsulation, 12V/24V Driver, Dmx-Compatible Controller, Power Supply Control Board, Weatherproof Junction Box, Flexible Conduits, Cable Routing Through Gi/Hdpe Conduit (Minimum 25 Mm Dia.), Including Termination, Tagging, Ferrule, Testing, Commissioning, And Integration With Existing Supply. Complete Including All Labour, Tools, Plants, Scaffolding, Anti-Uv Coating, Joint Sealing, Curing, Protection, And Finishing As Per Approved Drawings And The Direction Of Engineer-In-Charge. , 2. Sculpture - The Elder Craftsman Desiging, Fabrication Of 11 Ft High Life-Size Artisan Sculpture, Executed In Frp 6-8 Mm Thickness, Produced Using Hand Lay-Up Process, Reinforced With Csm 450 Gsm And Woven Roving 600 Gsm, Surface Gelcoat Resistant To Uv & Atmospheric Conditions. Internal Ms Support Frame Fabricated With Is 806/Is 1161 Compliant Steel Tubes, Welded As Per Is: 816, Ground Smooth, Inspected By Dye-Penetration Testing At Joints, And Coated With Zinc-Rich Epoxy Primer And Pu Topcoat. Sculpted Tools (Hammer, Chisel, Stone Block) To Be Integral Frp Components Reinforced With Ms Inserts Where Necessary. Exterior Finishing In Bronze Patina Multi-Layer System Including Base Coat, Shading Coat, Glaze, And Weather-Protective Clear Pu. Base: 3.5 Ft Reinforced Cement Concrete Pedestal (M-20), Steel Reinforcement Fe-500 Grade, Chemical Anchor Fixing System, Clad With Premium-Grade Granite Slabs (20-25 Mm Thick), Polished To 800-1000 Grit, Chamfered Edges, Fixed With Stainless Steel Clamps And Polymer-Based Adhesive. Rgb Lighting System: Supply And Installation Of Rgb Led Linear Lights/Spot Fixtures, Ip65/Ip67-Rated, With Aluminum Extrusion Channels, Pvc/Silicone Sealing, Dmx Controller, Waterproof Driver, 16-18 Gauge Copper Wires, Gi Conduits, Mcb Protection, Synchronization Of Lighting Sequences, Testing & Commissioning. Includes Earth Connection As Per Is:3043, Foundation Excavation/Backfilling, Hoisting, Alignment Using Spirit Level And Temporary Supports, Protective Anti-Uv Coat, Finishing Complete , Sculpture - Egksck Dk Lw;Z Eafnj (Sun Temple Of Mahoba) Desiging, Providing And Erecting 10 Ft High Frp Sculpture (10 Mm Thick) Fabricated Using Dual-Layer Woven Roving 600 Gsm And Csm 450 Gsm With Isophthalic Grade Resin System, Designed With Embedded Transparent/Colored Acrylic Panels (6-8 Mm Cast Acrylic) Supported Within Frp Recesses. The Sculpture Includes Internal Led Illumination Cavity With Access Hatch. Internal Ms Structure Designed As Per Structural EngineerS Certification For Wind Loadings Up To 180 Km/H. Surface Finishing To Be Golden Metallic Enamel, Multi-Coat System With Primer, Metallic Flakes Coat, Final Pu Topcoat. Base: 4 Ft Reinforced Cement Concrete Pedestal, Reinforcement Detailing As Per Structural Drawing, Fully Clad With Jaisalmer Yellow Stone, Machine-Cut And Mirror-Polished, Fixed With Ss Cramps. Electrical Works Include Ip-Rated Internal Led Modules, Drivers, Controller, Cable Trays Inside Sculpture, And Maintenance Access Door. Rgb Lighting System: Providing And Installing Rgb Led Accent Lighting, Ip65-Rated, With Programmable Controller, Dmx Interface Module, Gi Conduit, Copper Wiring, Junction Boxes, Mcb Protection, Earth Continuity Conductor, And Full Testing And Commissioning. Complete Including Foundation, Anchoring, Grouting, Cable Management, And Surface Finishing As Per Drawings. , 4. Sculpture - Fort Of Mangalgarh Desiging, Fabrication And Installation Of 10 Ft High Sculpture Made Of Treated Steel Scrap, Utilizing Ms Plates, Rods, Flats, Angles, Bars Of Select Thickness (4 Mm-10 Mm), Cleaned By Sandblasting (Sa 2.5 Standard), Welded Using Is-Approved Welding Electrodes, Full Penetration Welds Where Required, Visually Inspected And Tested. Surface To Undergo Rust-Induced Patina Treatment Through Chemical Oxidation, Sealed With Clear Epoxy Topcoat (2-3 Layers). Sculpture Supported On Heavy-Duty Internal Ms Frame Anchored To Reinforced Cement Concrete Plinth (M-20 Grade) Clad With Natural Stone (Random/Ashlar Masonry), Fixed With Ss Clamps. Rgb Lighting System: Providing And Fixing Rgb Led Flood Or Strip Lights, Ip65/67-Rated, On Anti-Corrosion Metal Brackets, Concealed Wiring, Dmx/Ir Controller, Driver Unit, Gi Conduit, Cable Protection, Mccb/Mcb As Required, Tagging, Termination, Testing, And Commissioning. Includes All Corrosion-Treatment Stages, Structural Frame Fabrication, Erection, Foundation Concreting, Anchor Bolt Fixing, Finishing Complete. , 5. Sculpture - Raja Parmal Desiging, Fabrication And Erection Of 12 Ft High Equestrian Statue, In Frp 10 Mm Thickness, Gel-Coated Finish, Multi-Layer Lamination, Sculpted Detailing On Armour, Horse Musculature, Ornaments, Weaponry. Internal Ms Structural Frame Designed With Triangulated Truss Geometry Ensuring Stability Against Wind-Induced Vibrations; Steel Tubes Treated With Sandblasting And Epoxy Primer. Plinth: 4 Ft Reinforced Cement Concrete Base With Fe-500 Reinforcement, Fully Clad With High-Grade Granite Slabs, Fixed With Ss Cramps (Grade 304/316). Engraved Stone Plaque Fixed With Hidden Anchors. Surface Finish: Antique Bronze Metallic Finish With Multi-Layer Pu Protective Coating. Rgb Lighting System: Installation Of Rgb Programmable Spotlight Array, Ip67-Rated, Dmx-Controlled, Drivers, Dimmers, Gi Conduits, Ryb Phase-Balanced Power Distribution, Earthing Per Is:3043, Labeling, Cable Routing, Testing & Commissioning. All Structural Fixing, Grouting, Verticality Adjustment, Surface Cleaning, And Protection Complete. , 6. Sculpture - Alha Desiging, Providing, Fabricating, And Installing 11 Ft High Frp Sculpture (8 Mm Thick), Layer Composition Csm 450 Gsm + Woven Roving 600 Gsm, High-Impact Resin System With Uv Stabilizer. Internal Structural Frame Fabricated Using Ms Pipes (50×50×2.5 Mm Min.), Epoxy Coated, Welded To Base Plate Fixed With Chemical Anchors. Mounted On Circular Reinforced Cement Concrete Plinth (M-20), Clad In Sandstone Slabs With Fine Chiselled Finish. The Base Includes Engraved Verse From Alha-Khand On Brass/Stone Plaque. Surface Finishing To Include Dark Bronze Metallic Paint, Pu Topcoat, Uv-Resistant Sealant. Rgb Lighting System: Providing And Fixing Ip65-Rated Rgb Led Edge-Lighting System Concealed In Plinth Recess, Provided With Dmx Controller, Drivers, Gi Conduit, Wiring, Earthing, And Commissioning. Includes Excavation, Foundation Concreting, Grouting, Anti-Uv Protective Coating, Finishing Complete. ,. Sculpture - Udal Desiging, Fabrication And Installation Of 11 Ft Dynamic Warrior Sculpture, Frp (8 Mm Thickness Minimum), Reinforced With Multi-Layer Frp Lamination, Internal Ms Structural Backbone Designed For Dynamic Cantilever Stresses Using Analysis Inputs. Dual-Tone Bronze-Steel Patina Finish By Multi-Layer Painting System. Mounted On Reinforced Cement Concrete Plinth (M-20), Granite Cladding 20-25 Mm Thick, Stainless Steel Cramps, Polymer Adhesive. Rgb Lighting System: Supply And Installation Of Rgb Led Spotlight/Linear Lighting System, Ip65/Ip67-Rated, Programmable, Including Driver, Controller, Conduits, Control Wiring, Earthing, Load Balancing, Testing, Commissioning. Includes Alignment, Installation, Anchor Bolt Tightening, Surface Finishing, Cleaning Complete In All Respects. , 8. Sculpture - Gorakhgiri Desiging, Providing And Fixing Spiritual Sculpture Depicting Gorakhnath Within An Abstract Hill-Form, Fabricated In Frp 10 Mm Thickness, Reinforced With Ms Skeleton Frame, Stress-Tested, Epoxy-Coated. Stone-Texture Frp Surface Created Using Multi-Layer Texture Coat, Shading Coat, And Final Weatherproof Pu Coat. Mounted On 3.5 Ft Reinforced Cement Concrete Plinth Clad With Sandstone, Fixed With Ss Cramps And Epoxy Adhesive. Brass Nameplate Fixed Flush. Optional Halo-Effect Led Illumination Integrated Within Sculpture With Concealed Access For Maintenance. Rgb Lighting System: Providing And Fixing Rgb Led Backlighting/Edge Lighting, Ip65/Ip67-Rated, Driver-Controlled, Dmx Controller Integration, Gi Conduit, Cable Management, Termination, Testing, Commissioning. Includes Foundation, Anchoring, Hoisting, Structural Inspection, Protective Coatings, Finishing Complete As Per Direction Of Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
30.
Railways #11305529 AOC
Supply Of Procurement Of Bpac/Ufsbiprocurement Of Bpac/Ufsbi,Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply Of Complete Set Of Block Proving Axle Counter Using Ufsbi For Single Line As Per Irs;S- 105/2012(Ver-0) Or Latest Consisting Of (A) Block Panel As Per Rdso Drg No. Rdso/S/32019=2N O.(B) Wired Relay Rack Consisting Of Rdso Approved & Pre Inspected Ufsbi And Rdso Approved & Pre I Nspected Relays With Bases As Per Rdso Drg No. Rdso/S/32020=2No.(C)Block Telephone As Per Rdso Drg No. Rdso/Spn/191/2006=02No.(D) Universal Fail Safe Block Interface=02 No. With Media Changeov Er [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Sse/C/Signal/Jallandhar Punjab 2.00 Set , Block Panel Bpac (Block Proving With Digital Axle Counter) Using Ufsbi Double Line Co Mplete Description As Per Anexxure Attached [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Page 1 Of 14 Run Date/Time: 01/12/2025 15:39:49Stores/Northern Rly Tender Document , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest With Latest Amendment. Complete Description As Per Annexxure Attached. [ Warrant Y Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing, Commissioning Of Block Proving With Axle Counter Using Bl Ock Panel And Ufsbi For Double Line Operation As Per Rdso Specification No.Irs:S-105/2012 (Ver.0) Or L Atest With Latest Amendment. Complete Description As Per Annexxure Attached. [ Warranty P Eriod: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing, And Commissioning (As The Case May Be) Of Block Proving B Y Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Spec No. Irs: S-105/2012 [Ver.0] With Latest Amendment. Each Set Consisting Of Following: (I) Universal Fail Safe Block Interface C Omplete With All Accessories As Per Spec No. Irs: S-104/2012 [Ver.0] With Latest Version And Amendme Nt. Qty-02 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drg No. Rdso/S/32017 For D Ouble Line ( With Latest Amdt.)- Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement A S Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg No. Rdso/S/32018 With Latest Amdt. And Supply Of All Type Of Relays (Iv) Block Telephone With Accesso Ries As Per Rdso Spec No. Rdso/Spn/191/2006, Qty-2 Nos. With All Type Lighting Protection And Inbuilt Automatic Media Change Over Of Modems Working On Redundant Channel For Data Transmission On Ofc/ Quad-1 Pair And Secondary Modem For Ufsbi For Use With Secondary Media Ofc/Quad-1 Pair. Or Suppl Y, Installation, Testing, And Commissioning (As The Case May Be) Of Microprocessor Based Station Maste R Block Panel For Double Line Block Instrument With Block Telephones As Per Rdso/Spn/175/2005 With Automatic Media Change Over Material And Description: - (I) Microprocessor Based Station Master Bloc K Panel For Double Line Instrument With Block Telephone As Per Rdso/Spn/175/2005- Version 1 Or Lates T (B) Block Telephone As Per Rdso Spec No.Rdso/Spn/191/2005 Or Latest (Inspection By Rdso)- Qty-2 Nos. (Ii) Supply Of Microprocessor Based Ssbpac (D) Block Instrument For Double Line As Per Rdso/Spn/ 175/2005 Version 1 Or Latest Qty-2 Nos (Iii) Supply Of Lighting And Surge Protection Devices Or Power Lin E 24 V Dc, Class-C Qty-02 Nos (Iv) Supply Of Lighting And Surge Protection Devices For Data Lines Class D Qty. 2 Nos. (V) Supply Of All Type Of Relays For Double Line (Vi) Auto Communication Change Over Units Working On Redundant Channel For Data Transmission On Ofc/Quad-1 Pair And Secondary Modem For Us E With Secondary Media Ofc/Quad-1 Pair. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver.1. 0) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interf Ace Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S/320 17 For Double Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32018 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Teleph One With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type Of Lig Hting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem For Bpac Usi Ng Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 2.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver.1. 0) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interf Ace Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S/320 17 For Double Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32018 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Teleph One With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type Of Lig Hting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem For Bpac Usi Ng Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 2.00 Set , Supply, Installation And Commissioning Of Block Proving By Axle Counter Using Block Pan El And Ufsbi For Double Line Operation As Per Rdso Specification No.Irs:S-105/2012 (Ver.0) With Latest Amendment. Each Set Consisting Of Following; (I) Universal Fail Safe Block Interface Complete With All A Ccessories As Per Spec. Irs:S-104/2012(Ver.0) With Latest Version And Amendment Qty-2 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drawing No. Rdso/S/32019 For Double Line (With Lates T Amendment).-Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg .No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. No. Rdso/S/32 020 With Latest Amendment And Supply Of All Type Of Relays (Iv) Block Telephone With Accessories As Pe R Rdso Spec. No. Rdso/Spn/191/2006. Qty-2 No. With All Type Lighting Protection Or (B) Supply, Install Ation, Testing, Execution And Commissioning Of Microprocessor Based Station Master Block Panel For Do Uble Line Block Instrument With Block Telephones As Per Rdso/Spn/175/2005 And Description: (1) Supp Ly Of (A) Microprocessor Based Station Master Block Panel For Double Line Instrument With Block Telepho Nes As Per Rdso/Spn/175/2005- Version 1 Or Latest (B) Block Telephone As Per Rdso Specification No. Rdso/Spn/191/2005 Or Latest (Inspection By Rdso)- Qty. 2 Nos (2) Supply Of Microprocessor Based Ss Bpac Block Instrument For Double Line As Per Rdso/Spn/175/2005 Version 1 Or Latest (Inspection By Rd So) Qty 2 Nos. (3) Supply Of Lighting And Surge Protection Devices Or Power Line 24V Dc, Class-C Qty. 2 Nos. (4) Supply Of Lighting And Surge Protection Devices For Data Lines Class-D Qty. 2 Nos. (5) Supply Of All Type Of Relays For Double Line [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Er (Sig)/Jrc, Punjab 2.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver 1.0 ) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interface Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S /32019 For Single Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sea Ling Arrangement As Per Rdso Drg No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32020 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Tel Ephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type O F Lighting Protection (V) Supply Of Of Automatic Media Changeover Along With Additional Modem For Bpa C Using Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 1.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver 1.0 ) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interface Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S /32019 For Single Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sea Ling Arrangement As Per Rdso Drg No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32020 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Tel Ephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type O F Lighting Protection (V) Supply Of Of Automatic Media Changeover Along With Additional Modem For Bpa C Using Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 5.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver 1.0 ) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interface Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S /32019 For Single Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sea Ling Arrangement As Per Rdso Drg No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32020 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Tel Ephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type O F Lighting Protection (V) Supply Of Of Automatic Media Changeover Along With Additional Modem For Bpa C Using Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 1.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver.1. 0) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interf Ace Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S/320 17 For Double Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32018 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Teleph One With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type Of Lig Hting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem For Bpac Usi Ng Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Page 5 Of 14 Run Date/Time: 01/12/2025 15:39:49Stores/Northern Rly Tender Document , Supply, Installation, Testing And Commissioning (As The Case May Be) Of Block Proving By Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Spec. No.Irs: S105/2012 [Ve R.0] With Latest Amendment. Each Set Consisting Of Following: (I) Universal Fail Safe Block Interface Com Plete With All Accessories As Per Spec No. Irs: S-104/2012 [Ver.0] With Latest Version And Amdt. Qty-0 2 Nos. (Ii) Block Panel Complete With Accessories As Per Rdso Drg. No.Rdso/S/32019 For Single Line (W Ith Latest Amdt.)-Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Dr G.No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. No. Rdso/S/3 2020 With Latest Amendment And Supply Of All Type Of Relays (Iv) Block Telephone With Accessories As P Er Rdso Spec.No.Rdso/Spn/191/2006, Qty-2 Nos. With All Type Lighting Protection. (V) Automatic Media Changeover Of Modems Working On Redundant Channels For Data Transmission On Ofc/Quad-1 Pair And Secondary Modem For Ufsbi For Use With Secondary Media Ofc/Quad-1 Pair. Or Supply, Installation, Te Sting & Commissioning (As The Case May Be) Of Microprocessor Based Station Master Block Panel For Si Ngle Line Block Instrument With Block Telephone As Per Rdso/Spn/175/2005 And Description: (I) Microp Rocessor Based Station Master Block Panel For Single Line Instrument With Block Telephone As Per Rdso /Spn/175/2005- Version 1 Or Latest (B) Block Telephone As Per Rdso Spec No. Rdso/Spn/191/2005 Or L Atest (Insp. By Rdso)-Qty-2 Nos. (Ii) Microprocessor Based Ssbpac (D) Block Instrument For Single Lines Per Rdso/Spn/175/2005 Version 1 Or Latest (Insp. By Rdso) Qty-2 Nos (Iii) Lighting And Surge Protectio N Devices Or Power Line 24 V Dc, Class-C Qty-02 Nos (Iv) Lighting And Surge Protection Devices For Data Lines Class D Qty. 2 Nos. (V) Supply Of All Type Of Relays For Single Line (Vi) Auto Communication Chang Eover Units Working On Redundant Channels For Data Transmission On Ofc/Quad-A Pair And Secondary Modem For Use With Secondary Media Ofc/Quad-1 Pair. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing, Commissioning Of Block Proving With Axle Counter Using Bl Ock Panel And Ufsbi For Single Line Operation As Per Rdso Specification No.Irs:S-105/2012 (Ver.0) Or La Test With Latest Amendment. Each Set Consisting Of Following; (I) Universal Fail Safe Block Interface Co Mplete With All Accessories As Per Spec. Irs:S-104/2012(Ver.0) With Latest Version And Amendment Qty -2 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drawing No. Rdso/S/32019 For Singl E Line (With Latest Amendment).- Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg.No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg . 6No. Rdso/S/32020 With Latest Amendment And Supply Of All Type Of Relays (Iv) Block Telephone With Accessories As Per Rdso Spec. No. Rdso/Spn/191/2006 Qty-2 No. With All Type Lighting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem As Per Manufacturers Specificati On For Bpac Using Ufsbi. This Includes Transportation Of Material From Consignee Store To Site Of Work. Or Supply, Installation, Testing And Commissioning (As The Case May Be) Of Microprocessor Based Stati On Master Block Panel For Single Line Block Instrument With Block Telephones As Per Rdso/ Spn / 175/2 005 And Description: (1) Microprocessor Based Station Master Block Panel For Single Line Instrument Wit H Block Telephones As Per Rdso/Spn/175/2005- Version 1 Or Latest (B) Block Telephone As Per Rdso Sp Ecification No. Rdso/Spn/191/2005 Or Latest-Qty. -2 Nos (8) Microprocessor Based Ssbpac (D) Black In Strument For Single Line As Per Rdso/Spn/175/2005 Version 1 Or Latest Qty 2 Nos. (Iii) Lightening And S Urge Protection Devices For Power Line 24V Dc, Class-C Qty. 2 Nos. (Iv) Lightening And Surge Protection Devices For Data Lines Class-D Qty. 2 Nos. (V) Supply Of All Type Of Relays For Single Line (Vi) Auto Comm Unication Changeover Units Working On Redundant Channels For Data Transmission On Ofc/Quad-1 Pair And Secondary Modern For Use With Secondary Media Ofc/Quad-1 Pair. [ Warranty Period: 30 Month S After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing And Commissioning (As The Case May Be) Of Block Proving By Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No . Irs: S-105/2012 (Ver.0) With Latest Amendment. Each Set Consisting Of Following; (I) Universal Fail Safe Bloc K Interface Complete With All Accessories As Per Sepc. Irs:S-104/2012 (Ver.0) With Attest Version And A Mendment Qty-2 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drawing No. Rdso/S/ 32017 For Double Line (With Latest Amendment).- Qty-02Nos. (Iii) Relay Rack With Die Locking And Sealing Arrangement As Per Rsso Drg.No. Rdso/S/32018 With Latest Amendment And Supplu Of All Type Of Rela Ys (Iv) Block Telephone With Accessories As Per Rdso Spec. No. Rdso/Spn/191/2006. Qty ? 02 No. With All Type Lighting Protection. (V) Automatic Media Changeover Of Modems Working On Redundant Channe Ls For Data Transmission On Ofc/ Quad-1 Pair And Secondary Modem For Ufsbi For Use With Secondary Media Ofc/Quad-1 Pair. Or Supply, Installation, Testing And Commissioning (As The Case May Be ) Of M Icroprocessor Based Station Master Block Panel For Double Line Block Instrument With Block Telephones As Per Rdso/ Spn/175/2005 And Description: (I) Microprocessor Based Station Master Block Panel For D Ouble Line Instrument With Block Telephones As Per Rdso/Spn/175/2005- Version 1 Or Latest (B) Block T Elephone As Per Rdso Specification No. Rdso/Spn/191/2005 Or Latest ? Qty-2 Nos. (Ii) Microprocessor Based Ssbpac (D) Block Instrument For Double Line As Per Rdso /Spn/175/2005 Version 1 Or Latest ? Qt Y 2 Nos. (Iii) Lightening And Surge Protection Devices For Power Line 24V Dc, Class-C Qty. 2 Nos. (Iv) Lig Htening And Surge Protection Devices Data Lines Class- D Qty. 2 Nos. (V) Supply Of All Type Of Relays? For Double Line (Vi) Auto Communication Changeover Units Working On Redundant Channels For Data Transmi Ssion On Ofc/Quad-1 Pair And Secondary Modem For Use With Secondary Media Ofc/Quad-1 Pair. [ Wa Rranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Sr Section Engineer/Sig- Punjab 2.00 Set
Contract Date: Jun 18, 2026 Contract Value : 2.41 Crore
Government Departments No of Bidders 1
Uttar Pradesh View Result →
31.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
32.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
33.
Communications and Information Technology  #11297723 AOC
Bids Are Invited For SITC of LT Panel having 2 nos 250A 4pole MCCBs as incomers and 8 nos 100A 4pole MCCBs for outgoings , SITC of LT Panel having 2 nos 100 A 4 pole MCCBs as incomers or outgoings , Point wiring with 1.5 sq mm FRLS PVC insulated Cu cond single core cable in steel conduit with modular switch plate and modular GI _Group C , Wiring for circuit or submain wiring with the 2 x 1.5 sq mm plus 1 x 1.5 sq mm earth wire , Wiring for circuit or submain wiring with the 4 x 1.5 sq mm plus 2 x 1.5 sq mm earth wire , Wiring for circuit or submain wiring with the 6 x 1.5 sq mm plus 3 x 1.5 sq mm earth wire , Wiring for circuit or submain wiring with the 2 x 2 .5 sq mm plus 1 x 2.5 sq mm earth wire , Wiring for circuit or submain wiring with the 4 x 2.5 sq mm plus 2 x 2.5 sq mm earth wire , Wiring for circuit or submain wiring with the 2 x 6 sq mm plus 1 x 6 sq mm earth wire , Wiring for light or power plug with the 2 x 4 sq mm alongwith 1 x 4 sq mm earth wire , Wiring for light or power plug with the 4 x 4 sq mm alongwith 2 x 4 sq mm earth wire , S and F 20 mm steel conduit , S and F 25 mm steel conduit , S and D of 1 x 1.5 sq mm FRLS PVC insulated Cu conductor , S and D of 2 x 1.5 sq mm FRLS PVC insulated Cu conductor , S and D of 3 x 1.5 sq mm FRLS PVC insulated Cu conductor , S and D of 2 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 3 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 6 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 9 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 12 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 24 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 36 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 48 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 54 x 2.5 sq mm FRLS PVC insulated Cu conductor , S and D of 3 x 4 sq mm FRLS PVC insulated Cu conductor , S and D of 6 x 4 sq mm FRLS PVC insulated Cu conductor , Sand F of GI box with modular plate and cover including P and F modular 3 pin 5 or 6 amps socket outlet and 5 or 6 amps switch , S and F of GI box with modular plate and cover including P and F modular 6 pin 5 or 6 and 15 or 16 amps socket outlet and 15 or 16 amps switch , S and F of 5 or 6 Amp modular switch , S and F of 3 pin 5 or 6 Amp modular socket outlet , S and F of 15 or 16 Amp modular switch , S and F of 6 pin 15 or 16 Amp modular socket outlet , S and F of RJ 45 Computer Socket Cat 6 , S and F of 4 Module or 125mm x 75mm size modules GI box with base and cover plate , S and F of 8 Module or 125mm x 125mm size modules GI box with base and cover plate , S and F of 3 Module or 100mm x 75mm size modules GI box with base and cover plate , S and F of 1 or 2 Module or 75mm x 75mm size modules GI box with base and cover plate , S and D of 1 Run of UTP 4 pair CAT 6 LAN cable , S and D of 2 Run of UTP 4 pair CAT 6 LAN cable , S and D of 3 Run of UTP 4 pair CAT 6 LAN cable , S and D of 4 Run of UTP 4 pair CAT 6 LAN cable , S and D of 6 Run of UTP 4 pair CAT 6 LAN cable , S and D of 8 Run of UTP 4 pair CAT 6 LAN cable , S and D of 16 Run of UTP 4 pair CAT 6 LAN cable , S and D of 20 Run of UTP 4 pair CAT 6 LAN cable , S and M end termination with RJ45 plug , S and F modular blanking plate , S and F of 450mm heavy duty exhaust fan along with louver shutters , S and F of 225mm heavy duty exhaust fan along with louver shutters , SITC of recess mounting type 36W LED Cool White luminaire of 2 Ft x 2 Ft size modular fitting , S and installation of 22 watt LED batten, 4 feet light fitting , S and F two module stepped type electronic fan regulator on the existing modular plate switch box , ITC of ceiling Fan including wiring the down rod , SITC of 1 phase 400 mm sweep, High speed wall mounted BLDC Motor fan , SITC of Round LED down lighter recess mounting Fitting of 15W, 230 volts, 50 Hz , S and F of control contactor for emergency lighting of rating 4 Amp, having coil voltage 230 volts, 50 Hz, with 2NO plus 2NC contacts , S and L of 75mm x 38 mm size One Compartment GI raceway , S and L of coupler for 75mm x 38 mm size GI raceway , S and F of JB 150mm x 150mm x 50m mm with 50_70 mm size GI height adjustable junction box with base and cover plate , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray bend , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray TEE , Supplying and installing 300mmx50mmx1.6mm thick perforated prepainted MS cable tray CROSS MEMBER , S and F of 8 way 4plus24 ways Double door horizontal type TPN sheet steel MCB DB_415V , S and F of 8 way Double door vertical type 415V TPN sheet steel MCB DB suitable for mounting MCCB as incomer 8 plus 8 plus 8 ways for outgoings , S and F of 8 way Double door SPN sheet steel MCB DB_240V , P and F of 100 A 4 pole MCCB , S and F of SP 5 amps to 32 amps rating 240 V C curve MCB , S and F of SPN 5 amps to 32 amps rating 240 V C curve MCB , S and F of TP 5 amps to 32 amps rating 415 V C curve MCB , S and F of TPN 5 amps to 32 amps rating 415 V C curve MCB , S and F single pole blanking plate in the existing MCB DB , P and F 6 SWG dia GI wire along with existing surface or recessed conduit or submain wiring or cable , P and F 4 mm dia Cu bare wire along with existing surface or recessed conduit or submain wiring or cable , Supplying of 4 core 35 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable , Supplying of 3.5 core 95 sq. mm Aluminium conductor PVC insulated and PVC sheathed or XLPE armoured cable , Laying and fixing of one number upto 35 sq. mm size cable on wall surface , Laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on wall surface , Laying and fixing of one number upto 35 sq. mm size cable on cable tray , Laying and fixing of one number above 35 sq. mm and upto 95 sq. mm size cable on cable tray , S and M end termination with brass compression gland and aluminium lugs for 4 x 35 sq. mm size Al cond cable , S and M end termination with brass compression gland and aluminium lugs for 3.5 x 95 sq. mm size Al cond cable , S and L of 2 x 1.5 sq mm Cu conductor armoured cable for fire alarm , S and F metal box of 75 mm x 75 mm x 60 mm deep nominal size , S and F 25 mm dia MS flexible pipe with PVC coating , ITC of Photo electric smoke detector , Dismantling of existing Fluorescent fittings _Cables_Wiring_MCB DBs , S and F of Double sided Exit sign Board with Green Super Bright LED , S and F of ISI marked ready to use CO2 type 4 point 5 Kg capacity fire extinguisher , S and L of of 1m x 2m size electrical insulation anti-skid rubber matting of 6mm thickness , Pvdg and installing of 24 port unmanaged Gigabit LAN switch 2 Layer supported , S and installing of 4U wall mounting rack for housing 24 port LAN switch , SITC of 30 Watt PDC housed LED street light fitting having IP66 protection , S and F of 3pin 5A ceiling rose on the existing junction box or wooden block , S and F of various sizes of MS boxes made out of 16 SWG MS sheet , SITC of Type_II TVSS unit as per UL 1449 standards for 3 phase 4wire plus Total Quantity :
Contract Date: Ref. Documents Contract Value : 14.99 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
36.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
37.
Defence #11286957 Technical Bid
Tender for Sch A Part- I To Ix: Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated As Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Dg Set) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (External Water Supply) , Total Amount Of Sch A Part-Ix (External Electric Supply) , Schedule A Part-X (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva Complete All As Specified And As Directed By Engr-In- Charge. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard/ Volina , Supply, Install, Testing And Commissioning Of Silent Diesel Engine Generating Set, 100 Kva/80 Kw, 1500 Rpm, 3 Phase, 415 V, 50 Hz, Power Supply Alternator Along With Fuel Tank, Control Panel., Battery And Complete Set Installed In Sound Acoustic Enclosure And Standard Accessories And Fittings With Power Factor 0.8, Plain Cement Concrete Foundation Suitable For The Generator Set As Per Manufacturers Instructions Complete With Standard Accessories And Microprocessor Based Integrated Dg Set Controller With Coupled To Alternator Rated At 100Kva/80 Kw At 415 Volts, Set Mounted On Channel Iron Base Frame Complete With Sub-Base With Batteries, Avm Pads And Std Panel All As Per Guideline Of Latest Cpcb Iv+ Norms All As Specified And Directed And Comprising Of The Following: , Note For Item No. 11.30 (I) Engine: Engine With Direct Injection, Water Cooled, 3 Cylinders, In-Line,4 Strokes Rated At Developing 126.8 Bhp @ 1500 Rpm For Continuous Duty Of Suitable For 100 Kva Alternator With Provision Of 10% Over Load For One Hour In Every 12 Hour Running Confirming To Bs 5514/ Iso 3046 Standard Totally Enclosed As Per Oem Specification And Directed By Engr-In-Charge. The Engine Has The Following Specification:- A) Mechanical Fip B) Mechanical Governor C) Turbocharger, Exhaust Manifold, Stainless Steel Exhaust Flexible Connection D) Radiator Cooled, With After Cooled E) Plate Type Lube Oil Cooler F) Filters G) Lube Oil H) Dry Type Replaceable Paper Element Air Cleaner J) Flywheel Housing And Flywheel To Suit Single Bearing Alternator K) Starting Motor-Electric, Battery Charging Alternator L) First Fill Lube Oil And Coolant (Ii) Alternator: Brushless Alternator, Self -Excited, Self -Regulated, Floor Mounted With All And / Or Roller Bearings, Statically And Dynamically Balanced Screen Protected Acoustic Enclosure Confirming To Is 4722 / Is 13364, Ip-23 Protection With H Class Insulation Limited Temperature Rise Of Class H, Automatic Voltage Regulator From No Load To Full Load, Ammeter Capacity Of Delivery 100 Kva, 415 Volts, 3 Phase, 50 Hz And Lagging For Ac Supply And Will Be Suitable For Tropical Conditions All As Per Oem And Directed By Engr-In-Charge. (Iii) Instrument Panel : Engine Instrument Panel Consisting Of On/Off Starting Switch With Key Lubricating Oil Pressure Gauge, Water Temperature Gauge, Battery Charging Indicating Lamp, Hour Meter With Rpm Indicator, Safety Control Against High Temperature Of Water, Over Speed Stop With Double Driver Adopter As Per Oem Specification And Directed By Enge-In-Charge. (Iv) Other Fittings: (A) Battery Charger : Battery Charger Having Electric Circuit Consisting Of Rectifiers, Capacitors And Resistance Etc. The Battery Charger Should Be Able To Charge 12 Volts 88 Ah Battery At A Time (V) Dg Set Shall Be Supplied Along With Acoustic Original Enclosure Of The Manufactures Suitable For 100 Kva Dg Set And All Connecting Accessories As Per Latest Cpcb Iv+ Norms , (Vi) The Diesel Oil, Lub Oil Etc. For Smooth Functioning Of Dg Set During Ph-I & Ph-Il Complete Testing And Full Tank Filing Of Diesel Oil After Ph-I & Ph-Ii Testing, Topping Of Lub Oil Etc. Required For Commissioning And Testing Of Dg Set. (Vii) Amf Panel: - Supply Installing Commissioning & Testing In Microprocessor Based Amf Panel Board Factory Made, Out Door Type Ip-65, Cubical Type, Vermin Proof, Dust Proof, Water Proof Made Out Of 3.15 Mm Thick Crca Sheet And Angle Iron Frame Of Size 50X50x6 Mm Inside Depth Not Less Than 50 Cm And Size Suitable To Accommodate The Following Accessories With Insulated Tpn Copper Busbar Of Rating Not Less Than 1.5 Times The Rated Capacity Of The Incomer Mccb Suitable For 100Kva Dg Set. Hinged Door With Locking Arrangement Duly Painted With Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Both Internally And Externally And Connecting With Cable With Lugs Including Internal Wiring With Copper Cable Of Suitable Size Using Lugs Compressing The Following Accessories All As Directed. (Notes : The Rate Quoted Shall Include For Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ) And Copper Bus Bar 240 Amps Duly Colour Sleeved Mounted On Epoxy Insulators-01 Set. Note:(I) Amf Panel Suitable For 100 Kva Dg Set To Connect With Grid Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. The Amf Panel Has The Following Specification:- A) 160A, 4 Pole Contactor For Alternator With Thermal Over Load Relay B) 160A, 4 Pole Contactor For Mains C) Mcb For Short Circuit Protection D) Indication Led (Dg On, Load On Dg, Main On, Load On Main, Battery Charge On) E) Push Buttons (Engine Start/Stop, Generator Contactor Close/Trip, Main Contactor Close/Trip If Provided, Fault Accept/Reset) F) Voltmeter & Ammeter And Other Connecting Accessories And Safety Features For Successful Auto Operation Of 100 Kva Dg Set. (Viii) Excavation, Earthwork And Provn Of Plain Cement Concrete Plinth Of Suitable Sizes For Installation Of Dg Set & Connected Accessories Complete As Per Oem/ Site Requirements. , S&F Square Profile Led Lighting Fixture With Extruded Polycorbonate, Environmental Friendly, Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output, With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. Make:Havells Led Pride Essential Cat No Lhexawp7un1w020 Or Equivalent Makes Cg/Philips/Wipro/Luker. , S&F Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb As Incomer Ip43 Protection Double Door: Plain 6 Way With Suitable Rated Busbar, Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separately. , S&F Mccb 4 Pole, 415 V, Adjustable Type Thermal Magnetic Release, 125 Amps With Breaking Capacity 25 Ka And Making Connection With Suitable Size Of Copper Lugs Etc Complete All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 50 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , M&L For Cutting Of Existing 40 Mm Dia Pipe For Inserting Tee Of Size 40X40x20 Mm Including Lead Joint And Excavation Etc Complete, All As Specified And As Directed , Supply, Install, Testing And Commissioning, Factory Made And Tested (Including Cpri Type Test Certified) Lt Panel Board Out Door Type, Floor Mounted, Compartmentalised And Ip-63 Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, All As Specified And Directed, Having Bus Bar Chamber With Insulated Aluminium Bus Bars 250 Amps Rating Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet And With Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Front And Rear Opening Type With Aprons For Cable Entry With Double Door Shutter And Locking Arrangement With And Including Following Items. (Notes : The Rate Quoted Shall Include Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ).Note: Panel Board Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. Incoming :- (A) Mccb 4 P, 415 Volt 160 Amps, 32Ka, 50 Hz With Fixed Thermal And Magnetic Setting -01 No Outgoing :- (B) Mccb 4 P, 415 Volt 125 Amps, 25Ka, 50 Hz -01 Nos. (C) Mccb 4 P, 415 Volt 63 Amps, 10 Ka, 50 Hz -02 Nos. (D) R,Y,B Indicators (E) Multifunction Digital Square Type Intelligent Panel Meter To Measure Voltage, Current, Frequency, & Power Factor - 01 No
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 13
Maharashtra View Result →
38.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
39.
Public Administrative Department #11281313 AOC
Tender For Supply Of Street Lighting Fixtures And Fittings Required For The Year 2026-2027 To Sivagiri Town Panchayat, 4 Feet Flourescent Tube Light , 40W Copper Choke , 40W Tube Light Starter , 36W / 40W Tubelight Electronic Choke , Tube Light Side Lock Holder , Insluation Gum Tape Roll - Isi , 1.5 Sq.Mm Wire [ Flex ] , 2.5 Sq.Mm Wire [ Flex ] , 4 Sq.Mm Wire [ Flex ] , 6 Sq.Mm Wire [ Flex ] , 1/18 Vir Copper Wire 1.5Sq.M , 3/20 Cts Copper Wire 4 Sq.M , 7/20 Cts Copper Wire 6 Sq.M , 1.5 Sq.Mm 3 Core Copper Cable , 2.5 Sq.Mm 3 Core Copper Cable , 4 Sq.Mm 3 Core Copper Cable , 6 Sq.Mm 3 Core Copper Cable , 10 Sq.Mm 3 Core Copper Cable , 16 Sq.Mm 3 Core Copper Cable , 6Amps To 32 Amps Sp Mcb , 40Amps 2Pole Isolator , 63Amps 4Pole Isolator , 16A Dp Switch , 32A D.P Switch , Sheet Sheal Enclosure For Mcb (4Pole) , Fuse Unit 16 Amps 240V , Fuse Unit 32 Amps 415V , Fuse Unit 63 Amps 415V , Fuse Unit 100 Amps 415V (Heavy Duty) , Fuse Unit 200 Amps 415V (Heavy Duty) , Main Switches Tpn 16 Amps , Main Switches Tpn 32 Amps , 63A 4Pmc Changeover Switch , 100A 4Pmc Changeover Switch , Main Switches Tpn 200 Amps , Electronic 7 Days 24 Hrs Programable Ditial Timer Clock , 63 Amps 4 Pole Contact With Coil , 9W Led Bulb Two Pin Holder Model , 15W Led Bulb Two Pin Holder Model , 48 Ceiling Fan With All Accessories , D.O.L Motor Starter Up-To 5 Hp , 1Hp Motor Single Phase Banel Board , 1.5Hp Motor Single Phase Banel Board , 2Hp Motor Single Phase Banel Board , 7.5Hp Three Phase Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 10 Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 12.5 Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 15 Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 20 Hp Three Phase Fasd - Auto-Start / Dry Run Protection Control Panel With Contactor, Relay, Auto-Start Preventor, Volt Meter, Amps Meter, Etc.. Complete In A Suitable Powder Coated Enclosure. , 50Mfd Condensor , 100 X 120 Mfd Condensor , 10 Mfd Condensor , 0 To 32A Amps Meter , 0 To 500V Volt Meter , 3/20 Aluminium Wire , 7/20 Aluminium Wire , 40Amps Contactor Switch , 23Amps Contactor Switch , 32Amps Contactor Switch , Street Light Champ Set With Pipe , Street Light Switch Box With Service Pipe , Electric Cutting Plyer , Electric Testor , Elertrician Safty Gloves , Screw Driver , 20 W Pvc Tube Light
Contract Date: Jun 13, 2026 Contract Value : 1.17 Lakh
Local Bodies No of Bidders 2
40.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
41.
Environment and Forests #11268702 AOC
Tender For Construction Of Cc Road Block Minakhan Ced-Iii Sdb 1445M Core Plan - Construction of Concrete Road from Harinhula Biswanath Mannas house (Lat- 22.52305̊ N, Long- 88.75532̊ E) to Gold vantha paschim mohanpur PWD road (Lat- 22.52971̊ N, Long- 88.75227 ̊ E)(Ch.0.00m to 1445.00m)at G.P.- Mohanpur, Block-Minakhan, under Minakhan Sub-Division of C.E.D.-III, S.D.B. Total Length = 1445.00m.(Core Plan). Sl. No. Item Description 1 Fine dressing and making the crest to correct camber and gtrade by cutting and filling earth where necessary including extra earth.. 2 Box cutting in road embankment in all kinds of soil and spreading the soil uniformely over the flanks and considerating and dressing the subgrade to correct camber and grade. 3 Labour for taking out brick-on-end edging including removing debris to flank or berm sorting out serviceable materials and stacking. 4 Labour for taking out old soling edging including removing debris(a) Single brick flat soling 5 Labour for laying soiling with departmental bricks including carriage of departmental bricks within a lead of 150 metres preparation of bed as necessary with brick joints properly filled in and packed with brick joints properly filled in and packed with local sand or powdered earth and including necessary cushion of similar materials below the soling (and in between layers when more than one layer is used)(d) Soling or dry pavement with one brick-on-edge laid in herring bone pattern on a layer of brick flat (thickness 75 mm. plus 125 mm) 6 Brick edging 75 mm wide with picked jhama bricks, laid true to line and level including cutting necessary trench in soil or in hard metalled surface, laying the bricks and repacking the trench (on both side of the edging) with spoils and ramming the same thoroughly complete as per direction.(b) Brick-on-end edging (250 mm) depth. 7 Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction.(e) Soling or dry pavement with one brick-on-edge on a layer of brick flat (thicknass 125 mm. plus 75 mm.) 8 Construction of Sub Base on prepared surface using Local Materials after mixing by mix in place method at OMC with suitable mixing equipments and spreading in uniform layers with spreading equipments capable of mixing the materials to the desired degree and spreading the mix materials uniformly acording to required line and level including screening the materials as necessary to the satisfaction of the EIC and compacting with vibratory roller to achieve the desired density, lighting, guarding and barricading including cost and carriage of all materials and making necessary earthen bundh of one meter wide on each side to protect the edges complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H(5th Revision).(i) For Construction of Sub Base by compacting 1st class brick aggregates (40 mm down) and sand (in proportion of 60:40).a) By using brick aggregates obtained from new Brick Bats and medium sand to be supplied by the agency. 9 Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction.(f) Soling or dry pavement with one brick-on-edge laid in herring bone pattern over a layer of brick flat (thickness 125 mm plus 75 mm) 10 Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction (b) Where staging is not required 11 Providing and laying nominal mix Cement concrete (with mix proportion 1:1.5:3)/M-20 grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm of Pakur or other approved variety including Screening and cleaning of aggregates, if necessary, both of approved quality and cement, as necessary, compacting by vibrator or other suitable means, cost of curing with water,cost for quality control, sampling, testing etc. and including placing a Separation membrane of impermeable PVC sheet 125 micron thick transparent or white in colour laid flat with minimum creases. Before placing the separation membrane, the sub-base shall be swept clean of all the extraneous materials. Wherever overlap of plastic sheets is necessary, the same shall be at least 300 mm and any damaged sheathing shall be replaced at the Contractors cost. Including carriage of all materials to site but excluding the cost of staging, shuttering and and reinforcement if any 12 Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight 13 Supplying, dressing and stacking at site bamboo pins above 5 cm. diameter and upto 7.5 cm. diameter. (Dia. to be measured at mid length). 14 Driving bamboo pins in standing or flowing water including scaffolding and driving appliances.(a) Where boats are not necessary. 15 Supplying, fitting and fixing with iron nails half split bamboo wailing pieces (av. dia. of bamboo not less than 5.0 cm.) 16 Supplying empty Cement bags in good condition 17 Filling empty Cement bags with dry earth or sand, stitching the bag (cost of thread included) and carrying and placing them in position and all incidental charges complete but excluding cost of filling materials, (Earth or sand) and gunny bags. 18 Earthwork from borrow pits over existing embankment or for repairs to embankment, closing breaches etc. within an initial lead of 30 metre and lift of 1.50 metre including breaking clods and depositing the same in layers not exceeding 25 cm. and rough dressing etc. complete as per profile. 19 Earthwork in excavation in all kinds of soil for making embankments, repairs to the embankment, closing breaches etc. as per profile including supply and transporting the earth by truck or tractor or any other mechanical means on land , including loading, transporting, unloading and stacking with all lifts bothways and head load where necessary and depositing the same on embankments, clannels, filling depressions in requisite profile, levelling as per direction of the Engineer-in-charge within A) Beyond 1.00 km and upto 2.00 km 20 Supplying,laying ,fitting &fixing R.C.C spun pipes and collers with cement morter (1:3) including fixing the pipes collers with jute,pitch etc. including the cost and carriage of spun pipes at site excluding the cost of collars.a) Spun pipes-300 dia, NP-2 Grade 21 Supplying RCC spun pipe collars including loading , carriage , unloading at site.a)Collar-300 dia, NP2 Grade 22 Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 23 Printing New Letters and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) English and Roman 24 Excavation in 0rdinary soil / mixed soil i.e. clay mixed with moorum, kankar, pebbles / silt dry or moist / slushy silt / sticky soil for WDS/WHS/ RESERVOIR / SFMIS etc. withhydraulic excavator or any other means including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirment of lines, grades and cross section and transporting to embankment / disposal site within all liftsand lead upto 1000 m including spreading, levelling disposed spoils at disposed area. (mode of measurment : pre work and post work) 25 Supplying and laying open mesh Jute Geotextile (JGT) for slope protection in road embankments, having overall weight of 500gm/m2, thickness 5 mm, width 1220 mm, strength 10 KN/m (in warp direction) and 7.5KN/m (in weft direction) on slopes of embankments dressed and cut to a stable gradient, providing side lapping of 100 mm and horizontal lapping of 250 mm including cutting and anchoring trenches upto 150 mm depth at top and bottom of slope and refilling the same with excavated earth as per direction complete. 26 GST as applicable - @ 18% 27 LabourWelfare cess - @ 1%
Contract Date: Dec 26, 2025 Contract Value : 76.74 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
42.
Power #11267487 Technical Bid
Tender for Rate Contract For Procurement Of Material In Respect Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized , Procurement Of Material In Respect Of Std Ganderbal For The Year 2025-26 Or Till Next Stage Contract Is Finalized , 11 Kv Horn Gap Fuse Set 3 Phase 200A , 11Kv Link Rods For 11Kv Link Set 22 Feet Long With Insulating Bottom Grip Bamboo/Carbon Fibre , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 11 Kv Isolator, Double Break,3-Pole, 600Amp, Horizontal Mounting Type, With Earth Switch Complete Including Clamps And Fittings , 11 Kv 3-Core Current Transformer 800-400/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 750-375/5-5A,( Metering, Protection, Differential Core) , 11 Kv 3-Core Current Transformer 600-300/5-5 A, ( Metering, Protection, Differential Core) , 11 Kv 2-Core Current Transformer 600-300/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 400-200/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 100-50/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 50-25/5-5 A, ( Metering, Protection) , 11 Kv 2-Core Current Transformer 20-10/5-5 A, ( Metering, Protection) , 11 Kv Potential Transformer 110V, Accuracy Class 0.5 , Tension Fittings For 0.1 Acsr Conductor 70Kn , Tension Fittings For 0.15 Acsr Conductor 70 Kn , Tension Fittings For 0.2 Acsr Conductor 120 Kn , 185 Sqmm, 3Core , 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 3 Core ,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 240 Sqmm, 3 Core,11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core, 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Indoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 630 Sqmm, Single Core 11 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 185 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 240 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 11 Kv 3 Core Xlpe Cable Armoured (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 120 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 300 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 400 Sqmm, 3 Core 33 Kv Cable Kit Outdoor Type(Make-3M/ Polycab/ Anchor/ Havells/ Gloster Or Equivalent) , 120 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 300 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 400 Sqmm, 33 Kv 3 Core Xlpe Cable(Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , 11 Kv 630 Mm² Single Core Xlpe Cable Armoured, Frls (Make-3M/ Polycab/ Anchor/ Havells/ Gloster) , Tripping And Closing Coils Must Have Burden Between 250 To 350 Watts At 30V Dc With Housing , Tripping Coil Of 11Kv Alind Make Vcb , Tripping Coil Of 11 Kv Er/Vijai Make Vcb , Tripping Coil Of 11Kv Electric Field Make Vcb , Tripping Coil Of 11Kv Abb Make Vcb , Tripping Coil Of 11Kv Crompton Make Vcb , Tripping Coil Of 11Kv Stelmac Make Vcb , Tripping Coil Of 11Kv Sudhir/Schneider Make Vcb , Tripping Coil Of 11Kv Pascal Make Vcb , Closing Coil Of 11Kv Alind Make Vcb , Closing Coil Of 11 Kv Er/Vijai Make Vcb , Closing Coil Of 11Kv Electric Field Make Vcb , Closing Coil Of 11Kv Abb Make Vcb , Closing Coil Of 11Kv Crompton Make Vcb , Closing Coil Of 11Kv Stelmac Make Vcb , Closing Coil Of 11Kv Sudhir/Schneider Make Vcb , Closing Coil Of 11Kv Pascal Make Vcb , 33 Kv Link Set Heavy Duty- Post Type, 800A Complete , 33Kv Link Rods Fibre/Bamboo Oil Impregnated With Insulated Bottom Grip 30 Feet Long , 33Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm. , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type A , 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm.Type B For 0.2 Acsr Conductor , 30 Kv Lightening Arrestor Set, 10 Ka, Station Class, Zno, Polymer Gap Less (Set Consists Of 03 No.) With All Accessories Required For Installation. , 33 Kv Isolator Without Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Isolator With Earthing Blade (36 Kv, 1250 A, Outdoor, 3 Poles, 25 Ka) Porcelain (Set Consist Of 03 Limb) With All Accessories Required For Installation , 33 Kv Current Transformer (33 Kv, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. Per Φ) 3-Core, 0.5 5P10, Ps-Class 3 Core- With All Accessories Required For Installation , 400-200/5-5 A (Metering, Protection And Differential Core ) , 250-125/5-5 A (Metering, Protection And Differential Core ) , 33 Kv Voltage Transformer (33 Kv/110 V, 1Φ, Multi-Core, Outdoor), (1No. Per Φ) With All Accessories Required For Installation , Tripping Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb) , Closing Coil Of 33 Kv Vcb With Metallic Housing (Crompton, Alind, Alstom, Bhel, Abb, Stelmac Etc ) , 33 Kv Polymer Post Insulator 36Kv,170Kv Impulse, Creepage Distance 1224M , Earthing Complete (Spike Earthing Rod 20Mm,2.5 Mtr Long) , Galvanised Earthing Strips 50X6 Mm/ 25X3mm , Galvanised Nuts & Bolts Of Different Sizes And Sorts , Pg Clamps For 0.1 Acsr Conductor 400A Pressure Di-Cast , Pg Clamps For 0.15 Acsr Conductor 500A Pressure Di-Cast , Pg Clamps For 0.2 Acsr Conductor 630A Pressure Di-Cast , Prefabricated Galvanised Channel Iron/ Angle Iron Of Different Sorts As Required , Prefabricated Galvanised Flat Iron Of Sorts 50/25 8/6Mm Thick , Instrument, Tools And Other Equipments , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick With Sliding Mechanism , Bamboo Ladder 25 Long , 12V/7Ah Led Handheld Searchlight (Andslite/Philipls/Microtech,Fos) , Tool Kit Of Suitable Size With Tools ( Stanley / Taparia/Jon/Jk/ Make) Comprising Of :- Double End Spanners With Increases Or Decreased Sized Ends And D/Ring Type Following Sizes And Numbers Spanners 6-0, 7-8, 9-9-10, 10-11, 11-12, 12-13, 14-15, 16-17, 18-19, 20-21, 20-22, 24-27, 25-28, 30-32, Complete Set Cushion Grip, Pipe Wrench 12 Inch 1 No. 24 Inch 1 No., 12 Adjustable Chrome Plated Wrench, 8 Combination Plier Line Man Plier, 8 Long Nose Plier Length Nose Plier, 9 Crimping Plier Set, 230Mm-, 7 Length Cutting Plier, Hex Key(Ln Key) Set 11Pc Metric (1.5, 2, 2.5, 3, 4, 5,5.5, 6, 8, 10Mm 12Mm), 27Pc-1/2 Sq. Dr 12Pt Socket Set ( Comprising Of ) 20 Pc :- 1/2 Drive 12 Point Sockets: 10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,30,32Mm 6 Pc :- 1/2 Drive Accessories : 2 Pc Extension Bar: 5 And 10(125 And 250Mm) Universal Joint, 1 Pc :- Spark Plug Socket 6 Point 13/16, 1 Pc Sliding T-Bar 10(254Mm); 1 Pc Flip-Drive Rachet., 1/4 Torque Rench, 914Mm , 36 Inch Bolt Cutter (Taparia Make, 12 Hacksaw Frame With 12 No. Spare Blades, Steel Body Retactable Utility Knife With 12 No. Spare Knives, 12H 340Gms Ball Pien Hammer Wooden Handle, 16 900Gms Ball Pien Hammer Wooden Handle, 5 Mtr Measuring Tape, Cold Chesel 7/8 (22Mm), Centre Punch 8Mm (15/16 )X 115Mm(4 1/2 ), Good Quality Multi Meter ( Fluke, Motwane, Meggar Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. 24 Magnetic Torpedo/ Beam Level (3Vails) 300Mm -1 No. & 600Mm -1No., Files Flat/Round Type 8-12 Inch Long, Srew Driver Set Comprising Of 12 No.S Long Shank Having Star/Flat Type Tips With Heavy Duty Tefon Grips , Hv Detectors For All Voltages. (With Fiber Rod Telescopic) , Pliers (Make-Taparia/Stanley) , 11 Kv Hand Gloves ( Make 3M/ Crystal) , Earth Resistivity Tester (0-1000 Ohms) (Make-Motwane/Megger/ Fluke/Markoni) With Auto-Manual Options , Digital Insulation Resistance Tester 5000V (Make-Sonel/Megger/ Fluke/Equivalent) , 10 Feet A Type Ladder , Portable Welding Set , Portable Blue Lamp(Gas) , Portable Blue Lamp (Kerosene) , Insulation Tester And Continuity Tester 2.5 Kv Withvarious Kits (Make- Fluke/ Megger/Equivalent) , Clamp Meter/ Multi Meter ( Fluke, Motwane, Meggar/Meeca Make ) Capable Of Measuring Current From Mili Amps To 400A, Voltage Ac-Dc Ranging From Milli Volts To 750 Volts Wired/Clamp On Type, Capacitance, Resistance Ranging From Mill Ohms To Mega Ohms, With Continuity And Diode Testing Options. , Heavy Duty Pulling & Lifting Machine 5 Mt , Control Relays With 3Oc+1Ef 2 Element Based Digital Of Following Make. , Mit- 114/104 (Er) Make. , Lnt M314a , Schneider , Simens 7Sr , Crompton 14C , Crompton 14Cn , Ashida 131A , Ashida 141 A/B , Ashida Adr241a , Ashida Adr242b , Abb Ref 615 , High Speed Master Relay With 12-63Vdc, 12-220 Vac Coil And 4 No+4Nc Driver Contacts , Battery Bank 30 V,100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type,High Impact Polyprophelene Copolymer Container,Flame Retardant (Exide/Amaron/Shoto/Hbl Make) , Battery Bank 36 V, 150 Ah Ultra Low Maintenance Tubular Battery Bank Compromising Of 3 No. Batteries Each Of 12 Volt (Hbl/Exide/Amaron/Luminous) , Battery Charger 36V, 40/60A With Full Wave Power Diode/Scr Based Recetification And Ripple Filtration. Avr Based Semi Digital With Inbuilt Autotransformer/Variant And Auto Manual Mode Having Digtal Precision Type/ Measuring Instruments, Led Type Indication, Inbuilt Buzzer/ Hoter Alarm During Technical Snags. The Charger Operating Ranges Must Be From 110V To 260 Vac Input Without Attoring Dc Output Through Smps , 7.5 Kva Servo Stablizer Copper Wound With Input Voltage Range 90V To 260V , Distilled Water For Batteries , Power Diodes P-Type/ N-Type ( 40 To 100 A) With Heat Shink , Charger Coil 240/36V Ac , Avr Card Compatile With Existing Chargers , Dc Volt Meter ( 0-60V) , Dimmer/Variac 110V To 260Vac , Power Transformer Equipments , Winding Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes Lv (Make-(Emco/Yoca/Excel) , Oil Temperature Meters For 3.15/4/5/6.3/10 Mva For Various Makes (Make-(Emco/Yoca/Excel) , Power Oil Conforming To Is:335 Standards , 33 Kv Bushing For 10 Mva Power Transformer , 33 Kv Bushing For 6.3 Mva Power Transformer , 33 Kv Bushing For 5/4/3.15 Mva Power Transformer , 33 Kv Bush Rods For 10 Mva Power Transformer , 33 Kv Bush Rods For 6.3 Mva Power Transformer , 33 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11 Kv Bushing For 10 Mva Power Transformer , 11 Kv Bushing For 6.3 Mva Power Transformer , 11 Kv Bushing For 5/4/3.15 Mva Power Transformer , 11 Kv Bush Rods For 10 Mva Power Transformer , 11 Kv Bush Rods For 6.3 Mva Power Transformer , 11 Kv Bush Rods For 5/4/3.15 Mva Power Transformer , 11Kv Outdoor Breaker Bushing , Oil Sealing For 33/11Kv Bushing Suitable For 1.0/3.15/2.5/6.3/10Mva , Miscellanous Items , Aluminum Thimble 120 Sqmm 3Mm Thick , Aluminum Thimble 185 Sqmm 3Mm Thick , Aluminum Thimble 240 Sqmm 3Mm Thick , Aluminum Thimble 300 Sqmm 3Mm Thick , Aluminum Thimble 400 Sqmm 3Mm Thick , Aluminum Thimble 630 Sqmm 4Mm Thick , Flexible Insulated Copper Bus/ Braid , Copper Bus Bars 12 Mm Thick , Aluminum Bus Bars 12 Mm Thick , T-Clamps For 0.1 Acsr 400A Presure Di-Cast , T-Clamps For 0.15 Acsr 500A Presure Di-Cast , T-Clamps For 0.20 Acsr 630A Presure Di-Cast , Isolator Pad Clamps 630A Presure Di-Cast , Single Phase Water Pump Motor, Power: 1 Hp , Led Lamp 15 Watt, B-22 Type (Make-Syska/Havells/Wipro/Surya/Ce/Gm) , 50 Watt Led Street Light With Fitting Complete (Make-Syska/Havells/Wipro/Surya/Ce/Gm) Ip-67 , Automatic Voltage Stablizer 5 Kva Copper Wound , 1.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 2.5 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 4 Sqmm Multistranded Copper Wire (Make-Polycab/Anchor/Havells/Kei/Ce) , 16 annual periodical maintenance Top (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Switch (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Socket (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Combine (Socket/Switch) (Make-Anchor/Havells/Crompton/Equivalent) , 16 annual periodical maintenance Extension Board With 5 Socket With Fuse And Switch (Make-Anchor/Havells/Crompton/Equivalent) , Pvc Flexible Pipe 1/2 Dia , Ppr Pipe 0.75 Dia , Ppr Pipe 0.5 Dia , Poly Propline Rope-20-30 Mm , Motorized Wood Cutter (58Cc 3.5Hpchain Saw With 22 Inch Cutter Bar Power Full Engine) , Pt Clamps , 33Kv La Clamps 6Mm Thick , Pad Clamps (Aluminuim /Bi Metalic 600A)Presure Di-Cost , Baby Insulators With Nuts & Bolts , 33Kv Ct Clamps ( Threaded And Band Type Cu Made) Tin Coated , Crimping Tool Xple Cable ( Hydraulic Type Upto 120 Sqmm To 630 Sqmm) , Korean Mink Blanket 220X240 Cm 4Kg Weight.Rate Be Quoted Per Kg , Pvc Insulated Copper Bus Bar (50 Mm X 12 Mm) Including Nuts And Bolts 1250A , 11 Kv Vacuum Interrupters (800A/600A) Suitable For Vijai, Er, S&S, Alind, Crompton, Electric Field, Abb, Stelmac, Pascal. Indoor/Outdoor Breakers. , 11 Kv Vacuum Interrupters (800A/600A) Suitable For L&T, Schneider, Sudhir Etc. , 11 Kv Vacuum Interrupters Housing Of Below Mentioned Make. , Vijai And Easun Reyrolle (Per Phase) , Alind (Assembly Upper Set/ Lower Set). , Abb/Electric Field/Crompton/S&S ( Per Phase) , Sudhir And Schneider (Per Phase) , Outdoor Type Pcvcb Upper And Lower Part(Per Phase) , 11 Kv Vcb Equipments Below (Make-Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Voltmeter 11Kv/110V , Ampere Meter , Selector Switch- 16 Amps Vss/Ass , Led Panel Indicators , Push Button With 2No+2Nc , Master Tripping Relay With 4No+4Nc , Hrc Fuse With Base -16 Amps , Connecting Ribs , Auxilary Switch With 8No+8Nc Complete With Bracket And Lever , Auxilary Switch With 12No+12Nc Complete With Bracket Lever , Auxilary Relay -30 A , Trip Circuit Supervision Relay , Bell/Buzzer , Arching Chamber , Tripping Mechanism , Re-Setting Links , Operating Shaft , Shower Contact , Isolating Sockets , Brass Chamber , Lifting Rods , Rollers , Closing Shaft , Contact Bar , Aluminum Chamber , Spring Tension Rod , Gear Assembly , Bmr Mechanism Complete , 33 Kv C&R Panel Equipments (Make Vijai/Alind/Schneider/Crompton/Siemens/Abb/Bhel/Pascal/ Electric Field/Ece/Mei/Alstom/Easun Reyrolle/S&S) , Bucholz Relay , Winding Temperature Relay , Oil Temperature Relay , Tripping Relay , Alarm Relay , Master Tripping Relay With 4No+4Nc , Tnc Switch 25 Amp. , Energy Meter Of Secure Make With Latest Series Premier 500 Of 11Kv Level And 33Kv Level With 5A Secondary. 11Kv/110V-5A / 33Kv/110V-5A , Electronic Hooter , Ampere Meter With Selector Switch , Voltmeter With Selector Switch , Hrc Fuse With Base , Bell/Buzzer , 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls , 12 Core . , 8 Core , 6 Core , 4 Core , 2 Core , 33 Kv Vcb Equipments (Make : Electricfield/Crompton/Abb/Bhel/Sudhir/Pascal/Beeco Lawrie/Megawin) , 33 Kv Vacuum Interrupter 1250A , 33 Kv Porcelain Post Insulator (Msli 1200+) , Operating Rods , Tripping/Closing Coils , Motor Charging 240, 1Cb, 0.1 Kv , Gasket , Operating Shaft , Mechanism Housing , Gear Assembly , Vacuum/Gas Charging Valve , Input/Output Housing Terminal Pads Din Pail Mounted Type , Xlpe Lt Cable 3.5 Core, Armoured, Fire Resistant Of Sizes , 95 Sq.Mm , 120 Sq.Mm , 185 Sq.Mm , 240 Sq.Mm , 300 Sq.Mm , 400 Sq.Mm , 2Mva/1Mva/630Kva/400Kva/250Kva/100Kva ,33/0.433 Kv, 3-Phase Distribution Transformers Eqiments: , 1600 annual periodical maintenance 4P Acb Drawal Type , Breaking Capacity 50Ka With Enclosure , Mccb ‐ 630 Amps , 36 Ka, 4P With Box Ics=100% Icu At 415 (Ka Rms) , Mccb ‐ 400 Amps , 36 Ka, 4P With Box , Mccb ‐ 250 Amps , 36 Ka, 4P With Box , Mccb ‐ 160 Amps , 36 Ka, 4P With Box , Mccb ‐ 1200 Amps , 36 Ka, 4P With Box , 120 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 240 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 400 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 630 Mm² Xlpe Lt Cable 1 Core, Armoured, Frls , 33/0.433 Kv Transformer Lv Bushing Suitable For 100Kva To 2 Mva: , 33/0.433 Kv Transformer Lv Bush Rods Suitable For 100Kva To 2 Mva: , Safety Equipments , Safety Helmets Make-3M/Akamgo/ Hilson) , 33Kv Hand Gloves (3M/Crystal/Honeywell/Meeco/Jyot) , Safety Shoes Valcanised Rubber Made (Make-Allen/ Hillson/ Gasoline/Liberty/Acme/Bata/Neosafe/Honetwell) , Safety Belts Shock Absorber Type (Make-3M/Neo) , Safety Glasses (Make-Stanley/ 3M / Allen) , Safety Jackets (Make-Allen/ Hillson/ Gasoline) , Rain Protective Suit Complete- Pant And Jacket Ip-67 Protected , Fire Extingiusher Co₂ Type Of 6.5 Kg Capacity For Control Room , Fire Extingiusher Abc/Dpc Type Of 9 Kg Capacity For Control Room , Refilling Of Empty/Expred Fireextinguishers , Rubber Mat 1Mx2m 19Mm Thick
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
43.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
44.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
45.
Public Administrative Department #11258216 AOC
Tender for Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole Cap Etc Supplying Of Swaged Steel Tubular Pole As Per Is 2713, Pt. Ii, 1980 For Following Designation And Of Following Dimensions.(Outside Dia & Thickness Are Given In Annexture -1) B) 4 Swg ;5.0 Mtrs; 45 Kg , Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe,, Pole Cap Etc. Erection Of Minipole Of Height 3.25 M To 5.0 M In cement concrete Foundation 0.46 M X 0.46 M X 0.9 M Depth Of 1:3:6 Cement Concrete With Hard Jhama Metal/Stone Chips Including Muffing Of 0.3M X0.3M X 0.3M Painting The Pole With 2 Coats Of Aluminium Paint Over A Coat Red Oxide. , Schedule Of Rates For Earthing Installations.Earthing Installation ... With Pipe Electrode.Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below:(A)By Isi Medium Gi Pipe. , Supply/Fixing Arm Bracket Of 50 Mm Bore Tubular Pipe (M.S.) Of 1. 5 M (5) Length For Fixing On 75/100 Mm Pole Top Including Supply/Fixing 4 Mm Thick M.S. Plate Welded With Bolts, Nuts & Clamps, Etc. As Required With Fabrication Work , Supply/Fixing Of Special Head Type M S Loop Box (3 Mm Thick) With Connecting Bar And Other Accessories Fixed On The Top The Pole As Required And As Per Direction Of Engineer-In-Charge. For 3 Phase Connection. , Supplying Al.Conductor Pvc Insulated And Sheathed Unarmoredcable (1.1Kvgrade, Gloster/Havells/Polycab). 10Sqmm X 2Core , Supply And Drawing Of 7/14 Swg Galvanised Stranded Wire For Drawing Unarmored Cable (Supply Of Cable Is Not Included In The Scope) By Catenary System Of Wiring With 3Nos. Reel Insulator Per Mtr. And Binding With Binding Wires Etc,As Reqd. For Drawing , Supplying A
Contract Date: Jun 09, 2026 Contract Value : 1.84 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
46.
Heavy Industries and Public Enterprises #11255514 AOC
Bids Are Invited For 094100031Transformer For Fault Current Monitoring, 80Mm 751031 , 095000346 Over Voltage Protection Dehn Venci, Typ1 Plus 2, 230V Ac, Remote 646293 , 091700350 Load-Break Switch Intermediate Installation, 3Pol., 40...1 666318 , 091700351 Main Switch Kit Grey For 3Va20,21,22 666326 , 091700352 Terminal Cover For 3Va20,21,22 666329 , 094500153 Motor Protection 3Rv2 7-10A Without Help Switch, Cagecl Amp 580810 , 094500154 Motor Protection Helpswitch 1N0 Plus 1Nc, Cageclahp 580818 , 094500155 3 Phase Busbar For 3 X 3Rv2, Extension, Cageclamp 582939 , 094500156 Connector For 3Rv2, S00, Cageclamp 582942 , 094500157 Motor Pr0tection 3Rv2 1, 4-2A Without Helpswitch, Cageclamp 580803 , 094500158 Wire Protection 5Sy4 Typ C, 6A With0ut Helpswitch 507085 , 094500159 Wire Protection Helpswitch For 5Sy4 433799 , 095000347 Current Protection Fuse 2-Pin., C2a, 230V, 30Ma 697828 , 094500160 Trafo Protection 3Rv24 5,5-8,0A Without Helpswitch, Cageclamp 580816 , 094200076 Transformer 2500Va, Pri 208-550 Vac, Sec 115-230 Vac 700414 , 092800394 System Lamp, 530Mm, 24V Dc, Led 594023 , 092800395 Connection For System Lighting Led 3M, Door Contact Switch 587884 , 091900048 Earthing Contact S0cket, Grey, Push-In, Germany 657183 , 094500161 Motor Protection 3Rv2 2,2-3,2 A Without Helpswitch, Cageclamp 580805 , 094500162 3 Phase Busbar For 2X 3Rv2, Infeed Left, Cageclanp 582938 , 313000345 Power Supply Sitop 3X320-575Vac-24 Vdc-40A 562833 , 094500163 Motor Protection 3Rv2 5,5 8A Without Helpswitch, Cageclamp 580809 , 094900070 Emergency Stop Butt0n, Signum 22Mm, Illuminated 641327 , 094900071 Holder Metal, Sirius Act 22Mm 641350 , 094900072 Switch Block, Sirius Act 22Mm, 1Nc, Front Mounting, Cagecl 641352 , 094900073 Switch Block, Sirius Act 22Mm, 1No, Front Mounting, Cagecl 641351 , 092800396 Led Module White, Sirius Act 22Mm, 24 Vdc, Frontmount, Cage 641360 , 092800397 Yellow Underlay Label For Emergenc, Sirius Act, Empty, 75M 641372 , 091600364 Workinghour Counter Ts Rail, 7 Digit Lcd, Without Reset, 2 628678 , 093600278 Fault Current Monitoring 0,03 40A, 2W, Cageclamp 751030 , 091700353 Power Relay 3Rt2-S00 5,5Kw, 3H, 1N0, 24 Vdc, Cageclamp 580669 , 091700354 Power Relay 3Rt2-S00 3Kw, 3H, 1N0, 24 Vdc, Cageclahp 580664 , 096600108 Screening Link Varist0r Without Led, 3Rt2- S00, 24-70 Vdc 580691 - 096600108 Screening Link Varist0r Without Led, 3Rt2-S00, 24-70 Vdc 580691 , 313000339 Opto Coupler 1No, 24 Vdc, 3A, Cage Clamp 527148 , 313000340 Patch Cable Ethernet Cat 6, 1 Meter 597005 , 094500167 Wire Protection 5Sy4 Typ C, 4A With0ut Helpswitch 433804 , 313000344 Power Supply Sitop Ac 120-230-500V-24 Vdc-5A 507285 , 094100032 System P0wer Supply Ps 25W, 24 Vdc, S7 1500 714676 , 313000341 Micro Memory Card S7-1500, 12Mbyte 595494 , 313000342 Front Plug 40-Pin S7 1500, Cage Clamp 599640 , 313000343 Fl Switch Sf 4Tx-1Fx Sc Ethernet 10-100 Rj45 24 Vdc Autocr 597854 , 094500164 Emv Flat Belt Earth Connection, Mb, 16Mm2, 200Mm, 10 Pcs. 597117 , 094500165 Putzmeister 550Cm, Ral 9005 695787 , 094500166 Skintop M32 Seal Insert For 1X Ethernet 6,5Mm 597606 , 472200016 Thermoelectric Cooler, 80W, 24 Vdc 750918 , 092800398 Led Module Blue, Sirius Act 22Mm, 24 Vdc, Frontmount, Cage 641359 , 092800399 Led Module Red, Sirius Act 22Mm, 24 Vdc, Frontmount, Cage 641356 , 313000335 Pressure Compensator M12x1,5 Stainless Steel 636016 , 091700355 Inspection Window Stainless Steel 600X522x38mm 559454 , 313000336 Operator Panel Tp6156 731587 , 313000337 Patch Cable Ethernet Cat 6, 3 Meter 597006 , 313000338 Fl Switch Sf 8Tx-1Fx Sc Ethernet 10-100 Rj45 24 Vdc Autocr 749636 , 091700356 Coupling Relay 859 1W, 24 Vdc, Cage Clamp 507804 Total Quantity : 153
Contract Date: Ref. Documents Contract Value : 37.97 Lakh
Boards / Undertakings / PSU No of Bidders 1
Madhya Pradesh View Result →
47.
Public Administrative Department #11252997 AOC
Bids Are invited for Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Installation, Testing And Commissioning Panel Mounting For Lighting Control; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Installation, Testing And Commissioning For Lights On/Off Based On Sunrise And Sunset Timing; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Installation, Testing And Commissioning Modular Contactor For Lighting Feeder Panel; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Installation, Testing And Commissioning Sovp For High Mast Light; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Installation, Testing And Commissioning Sovp For Pole Light Sub Feeder Panels; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Fixing, Testing Commissioning Of Wall/Floor Mounted Lt Panel, Primer Coated With Powder Coated Paint And Gasket For Dust/Vermin Proof Protection; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Fixing, Testing Commissioning Of Aluminium Bus Bar Strips; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Fixing, Testing Commissioning Of Led L Indicator; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Fixing, Testing Commissioning Of Analog Time Switch For Automatic On-Off Street Light; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Fixing, Testing Commissioning Of Mccb 63A To 100A, 25Ka, 4 Pole; No; Buyer Premises , Repair And Overhauling Service - Uninterruptible Power Supply (Ups); Supply, Fixing, Testing Commissioning Of Mccb 125A, 25Ka, 4 Pole; No; Buyer Premises
Contract Date: Ref. Documents Contract Value : 7.49 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
49.
Rural Development #11250007 AOC
Tender for Providing, Erecting And Supplying Various Different Electric Material For 1 Year @Gr Anchayat Kadamwakwasti , Electric Material This Rate Please Mentioned Include Gst Invoice Shall Be Prepared With Gst Tax Whatever Applicable On Material Rate Are Mentione With Gst , Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Angle Iron 50X50x6 Mm And 550 Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh -Pl/Bkt , Making Cement Concrete Foundation Including Excavation (60 X 60 X 150) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, (45 X 45 X 45) Cm /45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (Above 6 M To 9 M Poles) , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 6 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm. Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5 + 2 + 2M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 147 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm. Thickness (5 + 2.5 + 2.5 M) Length Respectively And Total 10 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 160 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia. With 4.5 X4.5 X3.65 Mm Thickness (5.60 + 2.7 + 2.7 M) Length Total 11 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 175 Kg.) As Per Specification No. . Oh-Pl/Stp , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting On Tubular Welded Pole With 40 Mm. Dia 1.0 M Long B Grade G.I. Pipe Along With Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No. Fg-Bkt/Bpc , Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series (For Lighting) In Provided Distribution Board As Per Specification No. Swswr/Mcb , Supplying And Erecting Insulated D.P. Switch Surface Type/Flush Type 32A 240Vwith Indicator Lamp & Fuse , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching On & Switching Off Street Light As Per Daily Sunset And Sunrise Respectively , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm (50 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting Suitable For Above 40W To 48W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Bajaj. Fgodf/Fls2. , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification Bajaj No Fg Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting Suitable For Above 70W- 75 Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls2 , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting 100W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 120 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 150 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg Odf/Fls-2 , 2-5-17 Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification Jno. Fg-Bkt/Bpc(2-9-2) , Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘B Class G.I. Pipe 1.2 M In Total Length Complete As Per Specification No. Fg-Bkt/Wb(2-9-3) , Supplying & Laying Pvc Armoured Cable 4Core 6Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 10 Sq Mm 7-1-15 , Supplying & Laying Pvc Armoured Cable 2Core 10 Sq Mm , Supplying & Laying Pvc Armoured Cable 2Core 6 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 16 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 25 Sq Mm , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 70 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 95 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 120 Sq. Mm. Aluminium Conductor With Continuous , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series (For Lighting) , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries (For Lighting) , Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete... , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block/Provided Box, With Necessary Materials. , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole , Supplying & Erecting Mains With 2X4 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Gma/Bw , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 annual periodical maintenance Three Phase L/T Contactor , Insulation Tape , Water Proof Tape , Cable Joint Kit Upto 25 Sq. Mm Cable , Cable Joint Kit Upto 35Sq. Mm To 95 Sq Mm Cable , Cable Joint Kit Upto 120Sq. Mm To 185 Sq Mm Cable , Cement Street Light Pole Clamp With Nut Bolt , M.S. Street Light Pole Clamp With Nut Bolt , Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes(Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Servicing And Primary Maintenance For Street Light Pole. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Reinforced Cement Concrete Road Cheasling Charges With Tractor Breaker (1 Hours) , Tree Triming For Overhead Line , Supplying & Erecting Street Light Control Panel Outdoor Type, For Single Phase 2 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 2 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete. , Supplying & Erecting Street Light Control Panel Outdoor Type, For Three Phase 4 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 4 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete , Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning , Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 9 W Led Fitting, 12V 18Ah Maintenance Free Lithium Battery, Min. 40 Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esd-Sol-Stl ( With 5 Years Warrantee ) , 4-3-13 Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 12W X 2 Nos. Led Fittings, 12V Min. 100Ah Maintenance Free Lithium Battery, Min. 120Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esdsol-Stl , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No.Oh-Pl/Opl. , Providing & Erecting 9 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 10 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 175 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 11 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 210 Mm A/F, Top 90 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For Highmast Of The Same Manufacturer With 63A Tpn Mcb Incomer, Single Dial Timer Switch, 45A Tp Contactor For Automatic Switching Of Luminaries, 2 Nos 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self-Lock, Gasket And Slanting Top Erected With cement concrete Foundation Complete , Supplying And Erecting 12.5 M (Clear Height) High Mast (Top 150Mm, Bottom- 360Mm) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 6 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Hm (Excluding Luminaries ). , Making Cement Concrete Foundation Including Excavation (60 X 60) Cm X Deep 1/6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm /45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (For Above 9 M Poles) , Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation As Per Specification No. Sw-Swr/Mfp , Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14/16 Swg Sheet, Outdoor Type, Single Phase, 240 V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Spn Mcb 63 A Auto/Manual Selector Switch,On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / cement concrete Foundation Complete. , Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 600Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 900 /1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. , 36 Watt Pcb , 36 Watt Driver , 50-60 Watt Pcb , 50-60 Watt Driver , 70 Watt Pcb , 70 Watt Driver , Highmast Repairing 100-150 Watt , Service Wire 4 Sq.Mm Isi Mark 2 Core , Service Wire 6 Sq.Mm Isi Mark 2 Core , Service Wire 10 Sq.Mm Isi Mark 2 Core , Frp Box Of Size 300 X200 X125 Mm 2.7Mm Thickness , 12W Led Bulb , 14W Led Bulb , 18W Led Bulb , 100 W Bulb , 200 W Bulb , 35 annual periodical maintenance Kitkat Fuse , 63 annual periodical maintenance Kitkat Fuse , Servie Reel Pvc , Retrofit T8 Led 18/20 Tube Light , Lamp Holder China Clay , Lamp Holder (Pendent) , 5Am Shocket Armor , 5Am Sawich Armor , Miter Box Singal Phase Pvc 300X150x420 , Miter Box 3Phase Pvc 540X600x200 , Miter Box Coted , 8M Sarfes Box & Pleat , Rsj Pole 9 Mtr , V Cross Arm 22 Kv , Cut Pont Set 22 Kv , Pin Insulater22 Kv , Disc Insulater 22 Kv , Nut Bolt , Conductor 55 Sq Mm Aac , Ht Stay Set , Lt Stay Set , Stay Wire , Gi Wire 8 Swg , Pole Errection , Conductor Errection , V Cros Fixing , Cutpoint Fixing , Mcb Box Metal 3Way , Supply Of Tiranga Pole As Per Sepcifucation 139.7Mm Od Pipe - 3Mtr 114.3Mm Od Pipe 1Mtr - 03 Nos 88.9Mm- Od Pipe - 2 Mtr Total 8 Mtr Pole , Day &Night Motin Sensor Auto On/Off Light Electronics(With Drayvar) , 9 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 6 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 6 Nos. E) Solar Panel Should Be Of 330 Watt --- 6 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , 6 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 4 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 4 Nos. E) Solar Panel Should Be Of 330 Watt --- 4 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , Gst Charges
Contract Date: Jun 08, 2026 Contract Value : 14.78 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
50.
Defence #11244966 AOC
Bids Are Invited For Cement Opc 43 Grade , Coarse Sand River Oblique M Sand , Graded Stone Aggregate 20Mm , Graded Stone Aggregate 40Mm , Pcc Solid Block Of Size 400 X 400 X 200Mm 75 Kg Per Cm2 , Tmt Steel 25Mm Grade Fe 500 , Tmt Steel 16Mm Grade Fe 500 , Tmt Steel 12Mm Grade Fe 500 , Binding Wire 18 Gauge , Oil Bound Distemper , Primer , Polythene Membrane Sheet Of Grade 2504 Thickness 150 Micron , Water Proofing Compound In 1 Kg Packing , Blast Door 3000 X 2800 As Per Elevation Including All Fitting And Fixtures , Ventilator 600Mm Dia With Mesh , Non Sparking Gritless Flooring Moc , Explosion Proof Ip66 Lighting And Fittings , Lightning Protection System Cu Strip Oblique Finial , 16 Sqmm 2 Core Lt Ug Xlpe Cable 200Rm And Point Wiring With 4 Nos Flame Proof Lights , Transparent Pipe 5Mm Dia Bore For Water Leveling Best Quality , Iron Bar 600Mmx16Mm To Bend 12Mm And 10Mm Tmt Bar , Industrial Safety Helmet , Hammer Weight 500 Gms With Wooden Handle , Plaster Trowel With Wooden Handle , Fish Line Best Quality , Plumb Bob Iron Best Quality , Galvanised Iron Pan Mortar Tasla 18 Gauge 16 Inch Dia Minimum Weight Of 1 Kg , Rammer Earth With Handle Min Wt 5 Kg Without Handle , Picks Axes With Chiesel And Point Ends Kudali 14 Cp Nominal Wt 3 Kg Overall Length Min 595Mm With Handle , Showel Square Nose 14 Gauge Tata High Carbon Steel Blade Size 310 X 245Mm Shaft Size 710Mm Fitted With Strong Steel Crutched Wooden Handles , Painting Brush 100 Mm Best Quality , Synthetic Tarpaulin 550 Gsm Of Size 30Ft X 30Ft Colour Green , Multipurpose Non Slip Rubber Reusable Gloves For Scrubbing Cleaning Brick Work Etc Colour Olive Green Oblique Black , Brick Trowel Steel 305 Mm , Heavy Duty Openable Props Oblique Scaffolding Made Of Ms Pipe Of 60 And 48Mm Dia Outer Pipe Od 60Mm And Inner Pipe Od 48Mm Of 3Mm All As Per Brief Technical Specification , Ms Centering Plates Of Size 90Cm X 60Cm Of Thickness 14 Guage With Two Stiffeners Including All Necessary Jointing Arrangement Nut Bolt And Jointing Cleats As Per Tech Specs , Portable Ms Body Needle Vibrator Machine With Power 3 Hp To 5 Hp Weight 20 To 30 Kg Petrol Engine With Min Frequency 50 Hz Voltage 200 To 300 For Concrete Vibrating As Per Tech Specs Total Quantity : 82784
Contract Date: Ref. Documents Contract Value : 1.49 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
West Bengal View Result →
TenderDetail
Loading tenders